  1. Switching overvoltage when disconnecting a combined 400 kVcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    consisting of overhead lines, crossbonded cable sections and shunt reactor has been created in PSCAD/EMTDC and verified against measurements with good results. Main focus has been put on the generation of switching overvoltages. It is shown that the generation of switching overvoltages is caused by slightly...... different resonant frequencies of the three phases which are reflected between the phases by mutual couplings in such a way that a low-frequent modulation appears in the phase voltages....

  2. Single-phase AutoReClosure ARC failure on 400 kV combinedcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    consisting of overhead lines, crossbonded cable sections and shunt reactor has been created in PSCAD/EMTDC and verified against measurements with good results. Main focus has been put on the likelihood of having a successful single-phase autoreclosure ARC in such a combined cable/OHL line....

  3. Application of VSC-HVDC with Shunt Connected SMES for Compensation of Power Fluctuation

    Science.gov (United States)

    Linn, Zarchi; Kakigano, Hiroaki; Miura, Yushi; Ise, Toshifumi

    This paper describes the application of VSC-HVDC (High Voltage DC Transmission using Voltage Source Converter) with shunt connected SMES (Superconducting Magnetic Energy Storage) for compensation of power fluctuation caused by fluctuating power source such as photovoltaics and wind turbines. The objectives of this proposed system is to smooth out fluctuating power in one terminal side of HVDC in order to avoid causing power system instability and frequency deviation by absorbing or providing power according to the system requirement while another terminal side power is fluctuated. The shunt connected SMES charges and discharges the energy to and from the dc side and it compensates required power of fluctuation to obtain constant power flow in one terminal side of VSC-HVDC system. This system configuration has ability for power system stabilization in the case of power fluctuation from natural energy source. PSCAD/EMTDC simulation is used to evaluate the performance of applied system configuration and control method.

  4. Power Quality Improvement Using an Enhanced Network-Side-Shunt-Connected Dynamic Voltage Restorer

    Science.gov (United States)

    Fereidouni, Alireza; Masoum, Mohammad A. S.; Moghbel, Moayed

    2015-10-01

    Among the four basic dynamic voltage restorer (DVR) topologies, the network-side shunt-connected DVR (NSSC-DVR) has a relatively poor performance and is investigated in this paper. A new configuration is proposed and implemented for NSSC-DVR to enhance its performance in compensating (un)symmetrical deep and long voltage sags and mitigate voltage harmonics. The enhanced NSSC-DVR model includes a three-phase half-bridge semi-controlled network-side-shunt-connected rectifier and a three-phase full-bridge series-connected inverter implemented with a back-to-back configuration through a bidirectional buck-boost converter. The network-side-shunt-connected rectifier is employed to inject/draw the required energy by NSSC-DVR to restore the load voltage to its pre-fault value under sag/swell conditions. The buck-boost converter is responsible for maintaining the DC-link voltage of the series-connected inverter at its designated value in order to improve the NSSC-DVR capability in compensating deep and long voltage sags/swells. The full-bridge series-connected inverter permits to compensate unbalance voltage sags containing zero-sequence component. The harmonic compensation of the load voltage is achieved by extracting harmonics from the distorted network voltage using an artificial neural network (ANN) method called adaptive linear neuron (Adaline) strategy. Detailed simulations are performed by SIMULINK/MATLAB software for six case studies to verify the highly robustness of the proposed NSSC-DVR model under various conditions.

  5. Optimum design of matrix fault current limiters using the series resistance connected with shunt coil

    Science.gov (United States)

    Chung, D. C.; Choi, H. S.; Lee, N. Y.; Nam, G. Y.; Cho, Y. S.; Sung, T. H.; Han, Y. H.; Kim, B. S.; Lim, S. H.

    2007-10-01

    In this paper we described the improved design for the matrix fault current limiters (MFCL). To do this, we used thin film-type superconducting elements. therefore it means that we can make the MFCL with minimized size and high switching speed because of the high current density and the high indexing value of superconducting thin film. Also we could minimize the bulky shunt coil using the connection of a series resistance with a shunt coil. Also we could effectively block up a leakage current in shunt coils under no-fault condition and simply control total impedances of a current-limiting part using this method. After we designed an appropriated 1 × 2 basic MFCL module with an applied voltage of 160 V, we enlarged it to a 2 × 2 MFCL module and a 3 × 2 MFCL module where applied voltages were 320 V and 480 V, respectively. Experimental results for our MFCL were reported in terms of various fault currents, variation of series resistance and so on. We think that these methods will be useful in the optimum design of an m × n MFCL.

  6. Optimum design of matrix fault current limiters using the series resistance connected with shunt coil

    International Nuclear Information System (INIS)

    Chung, D.C.; Choi, H.S.; Lee, N.Y.; Nam, G.Y.; Cho, Y.S.; Sung, T.H.; Han, Y.H.; Kim, B.S.; Lim, S.H.

    2007-01-01

    In this paper we described the improved design for the matrix fault current limiters (MFCL). To do this, we used thin film-type superconducting elements. therefore it means that we can make the MFCL with minimized size and high switching speed because of the high current density and the high indexing value of superconducting thin film. Also we could minimize the bulky shunt coil using the connection of a series resistance with a shunt coil. Also we could effectively block up a leakage current in shunt coils under no-fault condition and simply control total impedances of a current-limiting part using this method. After we designed an appropriated 1 x 2 basic MFCL module with an applied voltage of 160 V, we enlarged it to a 2 x 2 MFCL module and a 3 x 2 MFCL module where applied voltages were 320 V and 480 V, respectively. Experimental results for our MFCL were reported in terms of various fault currents, variation of series resistance and so on. We think that these methods will be useful in the optimum design of an m x n MFCL

  7. External thoracic duct-venous shunt in conscious pigs for long term studies of connective tissue metabolites in lymph

    DEFF Research Database (Denmark)

    Jensen, L T; Olesen, H P; Risteli, J

    1990-01-01

    An experimental animal model for lymph studies is described. Thoracic duct-venous shunt was established in 12 pigs. Shunt patency averaged 5.5 days. The composition of connective tissue metabolites in lymph and serum were investigated during a standardized surgical operation (thoracotomy) under...... instead of dogs and sheep in studies on lymph. The effect of surgery/anesthesia must be taken into consideration....

  8. Measurement ot the switching over-voltages at the disconnection of the high voltage shunt reactors in the Romanian power system

    Energy Technology Data Exchange (ETDEWEB)

    Stroica, Paul Constantin; Merfu, Ion; Stroica, Mihail; Merfu, Marius; Cojocaru, Florian; Stefan, Dinu; Cojocaru, Mihai

    2010-09-15

    The paper presents the measurements of the switching over-voltages made in the Romanian Power System, at the 400/220/110 kV Urechesti substation at the disconnection of a 400 kV, 100 MVAr shunt reactor type DFAL, Siemens, Germany, in 3 consecutive versions. The first one is for shunt reactor controlled by live-tank oil circuit breaker, the second one is for shunt reactor controlled by SF6 circuit breaker, and the third one is for shunt reactor controlled by SF6 circuit breaker and synchronize device.

  9. Congenital Intrahepatic Portosystemic Shunts

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Hee; Kim, Young Tong; Jou, Sung Shick; Shin, Hyeong Cheol [Soonchunhyang University, Asan (Korea, Republic of)

    2008-12-15

    Intrahepatic portosystemic shunts are an anomalous connection between the portal vein and hepatic vein/IVC, which may be either congenital or acquired secondary to liver cirrhosis or portal hypertension. Cases of congenital intrahepatic shunts are usually encountered in children and may spontaneously resolve. We report 5 cases of congenital intrahepatic portosystemic shunts in neonates and an adult

  10. Oculoplastic technique of connecting a glaucoma valve shunt to extraorbital locations in cases of severe glaucoma.

    Science.gov (United States)

    Rubin, Peter A D; Chang, Eli; Bernardino, Carlo Roberto; Hatton, Mark P; Dohlman, Claes H

    2004-09-01

    To describe a technique for inserting glaucoma shunts to the sinuses or the lacrimal sac as a means of lowering intraocular pressure in patients with refractory glaucoma associated with severe ocular surface disease. Nineteen patients with severe ocular surface disease necessitating a keratoprosthesis and with intractable glaucoma underwent placement of a modified Ahmed shunt to direct aqueous in the maxillary or ethmoid sinus or lacrimal sac. Intraocular pressure is presently well controlled without glaucoma medications in two thirds of patients. None of the patients had endophthalmitis. Established oculoplastic surgery techniques may be used to redirect aqueous to extraorbital locations and effectively lower intraocular pressure in patients with severe ocular surface disease and refractory glaucoma. This procedure has not been associated with endophthalmitis.

  11. Contamination of the transformer oil of power transformers and shunting reactors by metal-containing colloidal particles

    International Nuclear Information System (INIS)

    L’vov, S. Yu.; Komarov, V. B.; Bondareva, V. N.; Seliverstov, A. F.; Lyut’ko, E. O.; L’vov, Yu. N.; Ershov, B. G.

    2011-01-01

    The results of a measurement of the contamination of the oil in 66 transformers by metal-containing colloidal particles, formed as a result of the interaction of the oil with the structural materials (the copper of the windings, the iron of the tank and core etc.), and also the results of measurements of the optical turbidity of the oil in 136 transformers when they were examined at the Power Engineering Research and Development Center Company are presented. Methods of determining the concentration of copper and iron in transformer oil are considered. The limiting values of the optical turbidity factors, the copper and iron content are determined. These can serve as a basis for taking decisions on whether to replace the silica gel of the filters for continuously purifying the oil of power transformers and the shunting reactors in addition to the standardized oil contamination factors, namely, the dielectric loss tangent and the acidity number of the oil.

  12. Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study

    Directory of Open Access Journals (Sweden)

    Oramus Piotr

    2015-09-01

    Full Text Available Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.

  13. Flux shunts for undulators

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Hassenzahl, W.V.

    1993-05-01

    Undulators for high-performance applications in synchrotron-radiation sources and periodic magnetic structures for free-electron lasers have stringent requirements on the curvature of the electron's average trajectory. Undulators using the permanent magnet hybrid configuration often have fields in their central region that produce a curved trajectory caused by local, ambient magnetic fields such as those of the earth. The 4.6 m long Advanced Light Source (ALS) undulators use flux shunts to reduce this effect. These flux shunts are magnetic linkages of very high permeability material connecting the two steel beams that support the magnetic structures. The shunts reduce the scalar potential difference between the supporting beams and carry substantial flux that would normally appear in the undulator gap. Magnetic design, mechanical configuration of the flux shunts and magnetic measurements of their effect on the ALS undulators are described

  14. 30 CFR 56.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Explosives Electric Blasting § 56.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be kept shunted until...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... a stent is placed to keep the connection open and allow it to bring blood draining from ... veins within the liver. The shunt is kept open by the placement of a small, tubular metal ...

  16. Chaos and multi-scroll attractors in RCL-shunted junction coupled Jerk circuit connected by memristor.

    Directory of Open Access Journals (Sweden)

    Jun Ma

    Full Text Available In this paper, a new four-variable dynamical system is proposed to set chaotic circuit composed of memristor and Josephson junction, and the dependence of chaotic behaviors on nonlinearity is investigated. A magnetic flux-controlled memristor is used to couple with the RCL-shunted junction circuit, and the dynamical behaviors can be modulated by changing the coupling intensity between the memristor and the RCL-shunted junction. Bifurcation diagram and Lyapunov exponent are calculated to confirm the emergence of chaos in the improved dynamical system. The outputs and dynamical behaviors can be controlled by the initial setting and external stimulus as well. As a result, chaos can be suppressed and spiking occurs in the sampled outputs under negative feedback, while applying positive feedback type via memristor can be effective to trigger chaos. Furthermore, it is found that the number of multi-attractors in the Jerk circuit can be modulated when memristor coupling is applied on the circuit. These results indicate that memristor coupling can be effective to control chaotic circuits and it is also useful to reproduce dynamical behaviors for neuronal activities.

  17. Chaos and multi-scroll attractors in RCL-shunted junction coupled Jerk circuit connected by memristor

    Science.gov (United States)

    Zhou, Ping; Ahmad, Bashir; Ren, Guodong; Wang, Chunni

    2018-01-01

    In this paper, a new four-variable dynamical system is proposed to set chaotic circuit composed of memristor and Josephson junction, and the dependence of chaotic behaviors on nonlinearity is investigated. A magnetic flux-controlled memristor is used to couple with the RCL-shunted junction circuit, and the dynamical behaviors can be modulated by changing the coupling intensity between the memristor and the RCL-shunted junction. Bifurcation diagram and Lyapunov exponent are calculated to confirm the emergence of chaos in the improved dynamical system. The outputs and dynamical behaviors can be controlled by the initial setting and external stimulus as well. As a result, chaos can be suppressed and spiking occurs in the sampled outputs under negative feedback, while applying positive feedback type via memristor can be effective to trigger chaos. Furthermore, it is found that the number of multi-attractors in the Jerk circuit can be modulated when memristor coupling is applied on the circuit. These results indicate that memristor coupling can be effective to control chaotic circuits and it is also useful to reproduce dynamical behaviors for neuronal activities. PMID:29342178

  18. Chaos and multi-scroll attractors in RCL-shunted junction coupled Jerk circuit connected by memristor.

    Science.gov (United States)

    Ma, Jun; Zhou, Ping; Ahmad, Bashir; Ren, Guodong; Wang, Chunni

    2018-01-01

    In this paper, a new four-variable dynamical system is proposed to set chaotic circuit composed of memristor and Josephson junction, and the dependence of chaotic behaviors on nonlinearity is investigated. A magnetic flux-controlled memristor is used to couple with the RCL-shunted junction circuit, and the dynamical behaviors can be modulated by changing the coupling intensity between the memristor and the RCL-shunted junction. Bifurcation diagram and Lyapunov exponent are calculated to confirm the emergence of chaos in the improved dynamical system. The outputs and dynamical behaviors can be controlled by the initial setting and external stimulus as well. As a result, chaos can be suppressed and spiking occurs in the sampled outputs under negative feedback, while applying positive feedback type via memristor can be effective to trigger chaos. Furthermore, it is found that the number of multi-attractors in the Jerk circuit can be modulated when memristor coupling is applied on the circuit. These results indicate that memristor coupling can be effective to control chaotic circuits and it is also useful to reproduce dynamical behaviors for neuronal activities.

  19. Nuclear reactor incorporating locking device for threaded bolt connections

    International Nuclear Information System (INIS)

    Blaushild, R.M.

    1987-01-01

    A nuclear reactor having a pressure vessel and a first element is described comprising a core barrel situated within the pressure vessel. The core barrel has a baffle former secured in and to the core barrel by bolted connections, and a second element comprising baffle plates secured to the inner surface of the baffle former by bolted connections, with a locking device to prevent loosening of bolted connections between the baffle former and at least one of the elements. The baffle former and at least one element are held together by a headed, threaded bolt engaged in a bore coaxially extending in the baffle former and at least one element and threadedly engaged in a threaded section in at least the baffle former. The threaded section has first threaded of a first direction, with the head of the bolt engaged with a shoulder about the bore in at least one element to hold the baffle formed and at least one element together, the head of the bolt having a first diameter and a cavity, having an unsymmetrical wall thereabout, in the end surface thereof. It comprises a recess in at least one element coaxial with the bore forming a wall thereabout and extending inwardly from the outer surface of at least one element, the recess having a second diameter greater than the first diameter, with at least one element having second threads in the wall of a direction opposite the direction of the first threads of the threaded bore; a locking nut having a base with a downwardly depending cylindrical wall thereabout

  20. Congenital portosystemic shunts with and without gastrointestinal bleeding - case series

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Ying; Chen, Jun; Chen, Qi; Ji, Min; Pa, Mier; Qiao, Zhongwei [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China); Zhu, Hui [Fudan University Shanghai Cancer Center, Department of Radiology, Shanghai (China); Zheng, Shan [Children' s Hospital of Fudan University, Department of Surgery, Shanghai (China)

    2015-12-15

    The clinical presentation of congenital portosystemic shunt is variable and gastrointestinal bleeding is an uncommon presentation. To describe the imaging features of congenital portosystemic shunt as it presented in 11 children with (n = 6) and without gastrointestinal bleeding (n = 5). We performed a retrospective study on a clinical and imaging dataset of 11 children diagnosed with congenital portosystemic shunt. A total of 11 children with congenital portosystemic shunt were included in this study, 7 with extrahepatic portosystemic shunts and 4 with intrahepatic portosystemic shunts. Six patients with gastrointestinal bleeding had an extrahepatic portosystemic shunt, and the imaging results showed that the shunts originated from the splenomesenteric junction (n = 5) or splenic vein (n = 1) and connected to the internal iliac vein. Among the five cases of congenital portosystemic shunt without gastrointestinal bleeding, one case was an extrahepatic portosystemic shunt and the other four were intrahepatic portosystemic shunts. Most congenital portosystemic shunt patients with gastrointestinal bleeding had a shunt that drained portal blood into the iliac vein via an inferior mesenteric vein. This type of shunt was uncommon, but the concomitant rate of gastrointestinal bleeding with this type of shunt was high. (orig.)

  1. 30 CFR 57.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Electric Blasting-Surface and Underground § 57.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be...

  2. A connection-disconnection device for the nuclear reactor control rods

    International Nuclear Information System (INIS)

    Drean, H.; Breant, C.

    1992-01-01

    An automatic and relatively light system is developed to connect and disconnect the control rods in a nuclear reactor; it is designed to apply, in a controlled manner, constraints on the rods and to detect a possible misalignment of the connection-disconnection means in the corresponding butt

  3. Reactor

    International Nuclear Information System (INIS)

    Toyama, Masahiro; Kasai, Shigeo.

    1978-01-01

    Purpose: To provide a lmfbr type reactor wherein effusion of coolants through a loop contact portion is reduced even when fuel assemblies float up, and misloading of reactor core constituting elements is prevented thereby improving the reactor safety. Constitution: The reactor core constituents are secured in the reactor by utilizing the differential pressure between the high-pressure cooling chamber and low-pressure cooling chamber. A resistance port is formed at the upper part of a connecting pipe, and which is connect the low-pressure cooling chamber and the lower surface of the reactor core constituent. This resistance part is formed such that the internal sectional area of the connecting pipe is made larger stepwise toward the upper part, and the cylinder is formed larger so that it profiles the inner surface of the connecting pipe. (Aizawa, K.)

  4. Subgaleo-peritoneal shunt: An effective and safer alternative to lumboperitoneal shunt in the management of persistent or recurrent iatrogenic cranial pseudomeningoceles.

    Science.gov (United States)

    Kiran, Narayanam Anantha Sai; Thakar, Sumit; Mohan, Dilip; Aryan, Saritha; Rao, Arun Sadashiva; Hegde, Alangar S

    2013-01-01

    Subgaleo-peritoneal (SP) shunting for pseudomeningoceles (PMCs) is an effective and safer alternative as compared to the lumboperitoneal (LP) shunt. SP shunting was done in six patients (14-60 years) with persistent or recurrent PMCs using the cranial (ventricular part) and the distal parts of a Chhabra shunt connected by a rigid connector without any intervening chamber or valve. Two patients had undergone a prior LP shunt that had failed. One patient was unsuitable for a LP shunt placement. The PMC subsided completely in all the patients following the SP shunt. In one patient, the shunt got displaced and required repositioning. None of the patients developed symptoms of over-drainage or any other complication. All patients were asymptomatic at a mean follow-up of 15 months. These results suggest that SP shunting is a safe, simple, and effective alternative to the traditional LP shunt in the management of persistent or recurrent cranial PMCs.

  5. Raw materials problems in connection with fast breeder type reactors

    International Nuclear Information System (INIS)

    Hirsch, H.; Kreusch, J.

    1981-01-01

    The power supply by the FBR type reactors which depends upon the availability of essential raw materials such as Cr and Mo for structural and special steels is supposed to be less ensured than supply by fossil-fueled power plants. This contribution tries to verify this statement by means of estimates of the annual Cr and Mo demand, of the resources, production and consumption as well as by a study of the possibilities of recycling and substituting Cr and Mo. The only realistic alternative to the fast breeder type reactor is supposed to be a soft path of development according to the principle of decentralization, utilization of renewable energy sources regard to environmental protection, and use of less sophisticated technology. (DG) [de

  6. Switching overvoltage when disconnecting a combined 400 kVcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    400 kV power system and initiated by Danish TSO Energinet.dk after having measured the voltage of the cable/overhead line after disconnection. A particular decaying dynamic phase voltage containing voltages higher than the voltage before disconnection appeared. A simulation model for the entire system...

  7. Preloading of bolted connections in nuclear reactor component supports

    Energy Technology Data Exchange (ETDEWEB)

    Yahr, G T

    1984-10-01

    A number of failures of threaded fasteners in nuclear reactor component supports have been reported. Many of those failures were attributed to stress corrosion cracking. This report discusses how stress corrosion cracking can be avoided in bolting by controlling the maximum bolt preloads so that the sustained stresses in the bolts are below the level required to cause stress corrosion cracking. This is a basic departure from ordinary bolted joint design where the only limits on preload are on the minimum preload. Emphasis is placed on the importance of detailed analysis to determine the acceptable range of preload and the selection of a method for measuring the preload that is sufficiently accurate to ensure that the preload is actually within the acceptable range. Procedures for determining acceptable preload range are given, and the accuracy of various methods of measuring preload is discussed.

  8. Preloading of bolted connections in nuclear reactor component supports

    International Nuclear Information System (INIS)

    Yahr, G.T.

    1984-10-01

    A number of failures of threaded fasteners in nuclear reactor component supports have been reported. Many of those failures were attributed to stress corrosion cracking. This report discusses how stress corrosion cracking can be avoided in bolting by controlling the maximum bolt preloads so that the sustained stresses in the bolts are below the level required to cause stress corrosion cracking. This is a basic departure from ordinary bolted joint design where the only limits on preload are on the minimum preload. Emphasis is placed on the importance of detailed analysis to determine the acceptable range of preload and the selection of a method for measuring the preload that is sufficiently accurate to ensure that the preload is actually within the acceptable range. Procedures for determining acceptable preload range are given, and the accuracy of various methods of measuring preload is discussed

  9. Detachable connection for a nuclear reactor fuel assembly

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Karnesky, R.A.

    1986-01-01

    This patent describes a connection for releasably attaching a socket member to a tube. It consists of: a tube defined by a wall provided with circumferentially spaced openings adjacent one end; a housing having an internal thread formation and laterally spaced fingers at one end. The fingers have pins engagable within the tube openings, a socket member threadably received within the housing and have a tapered portion at one end for urging the fingers radially outwardly. It also contains a split retaining ring interposed between the housing and the socket member and completely encapsulated

  10. Expansion connection of socket in flow distributed cabin of heavy water research reactor inner shell

    International Nuclear Information System (INIS)

    Jiang Zhiliang; Li Yanshui

    1995-01-01

    Expansion connection of aluminium alloy LT21 socket in flow distributed cabin of Heavy Water Research Reactor (HWRR) inner shell is described systematically. The expansion connection technology parameters of products are determined through tests. They are as following: bounce value of inner diameter after expansion, expansion degree, space between socket and plate hole, device for expanding pipes, selection of tools for enlarging or reaming holes, manufacture for socket inner hole and cleaning after expansion

  11. Cell shunt resistance and photovoltaic module performance

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, T.J.; Basso, T.S.; Rummel, S.R. [National Renewable Energy Lab., Golden, CO (United States)

    1996-05-01

    Shunt resistance of cells in photovoltaic modules can affect module power output and could indicate flawed manufacturing processes and reliability problems. The authors describe a two-terminal diagnostic method to directly measure the shunt resistance of individual cells in a series-connected module non-intrusively, without deencapsulation. Peak power efficiency vs. light intensity was measured on a 12-cell, series-connected, single crystalline module having relatively high cell shunt resistances. The module was remeasured with 0.5-, 1-, and 2-ohm resistors attached across each cell to simulate shunt resistances of several emerging technologies. Peak power efficiencies decreased dramatically at lower light levels. Using the PSpice circuit simulator, the authors verified that cell shunt and series resistances can indeed be responsible for the observed peak power efficiency vs. intensity behavior. The authors discuss the effect of basic cell diode parameters, i.e., shunt resistance, series resistance, and recombination losses, on PV module performance as a function of light intensity.

  12. [Shunt and short circuit].

    Science.gov (United States)

    Rangel-Abundis, Alberto

    2006-01-01

    Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.

  13. Releasing method of connection of control rod and its drive mechanism in a reactor

    International Nuclear Information System (INIS)

    Ishida, Kazuo; Futatsugi, Masao.

    1976-01-01

    Object: To disengage a control rod from a control rod drive device in a boiling water reactor with a minimal failure of the device, when connection there between cannot be released in a normal manner. Structure: First, a part of a piston tube in the control rod drive device is withdrawn externally of a control rod housing and cut. Next, a discharge tool, which is designed to be connected with the cut piston tube, is connected to the remainder of the piston tube within the housing and the aforesaid piston tube is pushed into the index tube. The index tube is then cut by the discharge tool. Thus, the control rod drive device and the control rod may be separated. Thereafter, the control rod may be removed from the top of the reactor container whereas the control rod drive device removed from the bottom thereof. (Ikeda, J.)

  14. Shunt detection and measurement

    International Nuclear Information System (INIS)

    Grossman, W.

    1986-01-01

    Detection, localization, and quantification of intracardiac shunts are an integral part of the hemodynamic evaluation of patients with congenital heart disease. In most cases, an intracardiac shunt is suspected on the basis of the clinical evaluation of the patient prior to catheterization. However, there are several circumstances in which data obtained at catheterization should alert the cardiologist to look for a shunt that previously had not been suspected

  15. Splenophrenic portosystemic shunt in dogs with and without portal ...

    African Journals Online (AJOL)

    The possible existence of the same pattern of porto-caval connection in dogs having a single congenital portosystemic shunt (CPSS) and in dogs having multiple acquired portosystemic shunt (MAPSS) secondary to portal hypertension (PH) was evaluated. Retrospective evaluation of all CT examinations of patients having ...

  16. Ventriculoperitoneal Shunt Migration

    Directory of Open Access Journals (Sweden)

    Justin P Puller

    2017-01-01

    Full Text Available History of present illness: A 40-year-old female presented to our ED with left upper abdominal pain and flank pain. The pain had begun suddenly 2 hours prior when she was reaching into a freezer to get a bag of frozen vegetables. She described the pain as sharp, constant, severe, and worse with movements and breathing. The pain radiated to the left shoulder. On review of systems, the patient had mild dyspnea and nausea. She denied fever, chills, headache, vision changes, vomiting, or urinary symptoms. Her medical history was notable for obstructive sleep apnea, gastroesophageal reflux disease, arthritis, fibromyalgia, depression, obesity, and idiopathic intracranial hypertension. For the latter, she had a VP (ventriculoperitoneal shunt placed 14 years prior to this visit. She had a history of 2 shunt revisions, the most recent 30 days before this ED visit. Significant findings: An immediate post-op abdominal x-ray performed after the patient’s VP shunt revision 30 days prior to this ED visit reveals the VP shunt tip in the mid abdomen. A CT of the abdomen performed on the day of the ED visit reveals the VP shunt tip interposed between the spleen and the diaphragm. Discussion: VP shunts have been reported to migrate to varied locations in the thorax and abdomen. Incidence of abdominal complications of VP shunt placement ranges from 10%-30%, and can include pseudocyst formation, migration, peritonitis, CSF ascites, infection, and viscus perforation. Incidence of distal shunt migration is reported as 10%, and most previously reported cases occurred in pediatric patients.1 A recent retrospective review cited BMI greater than thirty and previous shunt procedure as risk factors for distal shunt migration.2 The patient in the case presented had a BMI of 59 and 3 previous shunt procedures.

  17. New control strategy for grid connecting of wind turbine inverter without converter reactor

    DEFF Research Database (Denmark)

    Rasmussen, Tonny Wederberg; Sørensen, Kasper B.; Bjørneboe, Daniel

    2013-01-01

    Wind turbines and the belonging converters increase in size and price. A reduction in the number of main components is desirable while it reduces need of space, investments and increases the efficiency. A wind turbine contains both a converter reactor and a step up transformer. The paper presents...... theory and laboratory measurements for a new control strategy which make it possibly to connect a wind turbine converter to the utility grid without using the converter reactor or make measurements at the high voltage side of the transformer. The capability to control the DC voltage and reactive power...

  18. High flux testing reactor Petten. Replacement of the reactor vessel and connected components. Overall report

    International Nuclear Information System (INIS)

    Chrysochoides, N.G.; Cundy, M.R.; Von der Hardt, P.; Husmann, K.; Swanenburg de Veye, R.J.; Tas, A.

    1985-01-01

    The project of replacing the HFR originated in 1974 when results of several research programmes confirmed severe neutron embrittlement of aluminium alloys suggesting a limited life of the existing facility. This report contains the detailed chronology of events concerning preparation and execution of the replacement. After a 14 months' outage the reactor resumed routine operation on 14th February, 1985. At the end of several years of planning and preparation the reconstruction proceded in the following steps: unloading of the old core, decay of short-lived radioactivity in December 1983, removal of the old tank and of its peripheral equipment in January-February 1984, segmentation and waste disposal of the removed components in March-April, decontamination of the pools, bottom penetration overhauling in May-June, installation of the new tank and other new components in July-September, testing and commissioning, including minor modifications in October-December, and, trials runs and start-up preparation in January-February 1985. The new HFR Petten features increased and improved experimental facilities. Among others the obsolete thermal columns was replaced by two high flux beam tubes. Moreover the new plant has been designed for future increases of reactor power and neutron fluxes. For the next three to four years the reactor has to cope with a large irradiation programme, claiming its capacity to nearly 100%

  19. Transjugular intrahepatic portosystemic shunt

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Han, Joon Koo; Chung, Jin Wook; Han, Man Chung [Seoul National University College of Medicidne, Seoul (Korea, Republic of)

    1992-05-15

    As a new interventional procedure for the control of variceal bleeding, a portosystemic shunt can be established with the installment of metallic stent through the transjugular approach. In order to evaluate the clinical usefulness of the procedure, transjugular intrahepatic portosystemic shunt procedure were performed in 5 patients with variceal bleeding due to liver cirrhosis. The metallic stents were mainly a self expandable Wallstent (Schneider, Switzerland), An 8 to 10 mm shunt was formed by the insertion of the stent and balloon dilatation after puncture of the proximal portal vein from the right or middle hepatic vein. The patency of the shunt was proven by portography after the procedure. The portal pressure measured in 3 patients before and after the procedure improved with decrease from 31 mmHg to 25 mmHg. The procedure failed in 1 patient due to pre-existing portal vein thrombosis. During the follow-up period from 1 month to 4 months, shunts were patent in all 4 patients. However, hepatic encephalopathy occurred in one patient one week following the procedure. Though the follow-up period was not long enough for full evaluation, we found the transjugular intrahepatic portosystemic shunt was a safe and effective procedure for the control of variceal bleeding by lowering the portal pressure. For the appropriate application for this procedure, the optimal size of the shunt and optical degree of the resultant decompression are yet to be determined in the future.

  20. FEM analysis of mechanical behaviour of coil support connections in Wendelstein 7-X fusion reactor

    International Nuclear Information System (INIS)

    Krzesinski, G.; Zagrajek, T.; Marek, P.; Dobosz, R.; Czarkowski, P.; Kurzydlowski, K.J.

    2006-01-01

    The objective of Wendelstein 7-X project is the stellarator-type fusion reactor. In this device plasma channel is under control of magnetic field coming from magnet system of very complicated shape, made of 70 superconducting coils symmetrically arranged in 5 identical sections. Every coil is connected to central ring with two extensions which transfer loads resulting from electromagnetic field and gravity. The aim of this work was to analyse mechanical behaviour of the bolted connections using detailed 3D finite element models. All simulations were performed assuming elasto-plastic behaviour of the materials, assembly stresses and friction contacts between different parts of the connections. Stress distributions, displacements, forces acting on the bolts and welds were studied using standard and submodeling routines. The results were subsequently used to optimize the design of critical central support elements. (author)

  1. Hydrocephalus and Shunts

    Science.gov (United States)

    ... of a problem. Because of the complexity, a neurosurgeon is the best person to diagnosis and treat ... type of shunt is best for whom. So neurosurgeons usually pick ones that they think are best. ...

  2. A new method to evaluate the sealing reliability of the flanged connections for Molten Salt Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qiming, E-mail: liqiming@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Chinese Academy of Sciences, Shanghai 201800 (China); Tian, Jian; Zhou, Chong [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Chinese Academy of Sciences, Shanghai 201800 (China); Wang, Naxiu, E-mail: wangnaxiu@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Chinese Academy of Sciences, Shanghai 201800 (China)

    2015-06-15

    Highlights: • We novelly valuate the sealing reliability of the flanged connections for MSRs. • We focus on the passive decrease of the leak impetus in flanged connections. • The modified flanged connections are acquired a sealing ability of self-adjustment. • Effects of redesigned flange configurations on molten salt leakage are discussed. - Abstract: The Thorium based Molten Salt Reactor (TMSR) project is a future Generation IV nuclear reactor system proposed by the Chinese Academy of Sciences with the strategic goal of meeting the growing energy needs in the Chinese economic development and social progress. It is based on liquid salts served as both fuel and primary coolant and consequently great challenges are brought into the sealing of the flanged connections. In this study, an improved prototype flange assembly is performed on the strength of the Freeze-Flange initially developed by Oak Ridge National Laboratory (ORNL). The calculation results of the finite element model established to analyze the temperature profile of the Freeze-Flange agree well with the experimental data, which indicates that the numerical simulation method is credible. For further consideration, the ideal-gas thermodynamic model, together with the mathematical approximation, is novelly borrowed to theoretically evaluate the sealing performance of the modified Freeze-Flange and the traditional double gaskets bolted flange joint. This study focuses on the passive decrease of the leak driving force due to multiple gaskets introduced in flanged connections for MSR. The effects of the redesigned flange configuration on molten salt leakage resistance are discussed in detail.

  3. A new method to evaluate the sealing reliability of the flanged connections for Molten Salt Reactors

    International Nuclear Information System (INIS)

    Li, Qiming; Tian, Jian; Zhou, Chong; Wang, Naxiu

    2015-01-01

    Highlights: • We novelly valuate the sealing reliability of the flanged connections for MSRs. • We focus on the passive decrease of the leak impetus in flanged connections. • The modified flanged connections are acquired a sealing ability of self-adjustment. • Effects of redesigned flange configurations on molten salt leakage are discussed. - Abstract: The Thorium based Molten Salt Reactor (TMSR) project is a future Generation IV nuclear reactor system proposed by the Chinese Academy of Sciences with the strategic goal of meeting the growing energy needs in the Chinese economic development and social progress. It is based on liquid salts served as both fuel and primary coolant and consequently great challenges are brought into the sealing of the flanged connections. In this study, an improved prototype flange assembly is performed on the strength of the Freeze-Flange initially developed by Oak Ridge National Laboratory (ORNL). The calculation results of the finite element model established to analyze the temperature profile of the Freeze-Flange agree well with the experimental data, which indicates that the numerical simulation method is credible. For further consideration, the ideal-gas thermodynamic model, together with the mathematical approximation, is novelly borrowed to theoretically evaluate the sealing performance of the modified Freeze-Flange and the traditional double gaskets bolted flange joint. This study focuses on the passive decrease of the leak driving force due to multiple gaskets introduced in flanged connections for MSR. The effects of the redesigned flange configuration on molten salt leakage resistance are discussed in detail

  4. Pathophysiology of shunt dysfunction in shunt treated hydrocephalus

    DEFF Research Database (Denmark)

    Blegvad, C.; Skjolding, A D; Broholm, H

    2013-01-01

    We hypothesized that shunt dysfunction in the ventricular catheter and the shunt valve is caused by different cellular responses. We also hypothesized that the cellular responses depend on different pathophysiological mechanisms....

  5. Transients in reactors for power systems compensation

    Science.gov (United States)

    Abdul Hamid, Haziah

    This thesis describes new models and investigations into switching transient phenomena related to the shunt reactors and the Mechanically Switched Capacitor with Damping Network (MSCDN) operations used for reactive power control in the transmission system. Shunt reactors and MSCDN are similar in that they have reactors. A shunt reactor is connected parallel to the compensated lines to absorb the leading current, whereas the MSCDN is a version of a capacitor bank designed as a C-type filter for use in the harmonic-rich environment. In this work, models have been developed and transient overvoltages due to shunt reactor deenergisation were estimated analytically using MathCad, a mathematical program. Computer simulations used the ATP/EMTP program to reproduce both single-phase and three-phase shunt reactor switching at 275 kV operational substations. The effect of the reactor switching on the circuit breaker grading capacitor was also examined by considering various switching conditions.. The main original achievement of this thesis is the clarification of failure mechanisms occurring in the air-core filter reactor due to MSCDN switching operations. The simulation of the MSCDN energisation was conducted using the ATP/EMTP program in the presence of surge arresters. The outcome of this simulation shows that extremely fast transients were established across the air-core filter reactor. This identified transient event has led to the development of a detailed air-core reactor model, which accounts for the inter-turn RLC parameters as well as the stray capacitances-to-ground. These parameters are incorporated into the transient simulation circuit, from which the current and voltage distribution across the winding were derived using electric field and equivalent circuit modelling. Analysis of the results has revealed that there are substantial dielectric stresses imposed on the winding insulation that can be attributed to a combination of three factors. (i) First, the

  6. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Faraj, Walid, E-mail: wf07@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Khalife, Mohammad, E-mail: mk12@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); El-Merhi, Fadi, E-mail: fe19@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Saade, Charbel, E-mail: cs39@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Hallal, Ali, E-mail: ah05@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Haydar, Ali, E-mail: ah24@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon)

    2015-08-15

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications.

  7. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Faraj, Walid; Khalife, Mohammad; Al-Kutoubi, Aghiad; El-Merhi, Fadi; Saade, Charbel; Hallal, Ali; Haydar, Ali

    2015-01-01

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications

  8. Cooling system for the connecting rings of a fast neutron reactor vessel

    International Nuclear Information System (INIS)

    Martin, J.-P.; Malaval, Claude

    1974-01-01

    A description is given of a cooling system for the vessel connecting rings of a fast neutron nuclear reactor, particularly of a main vessel containing the core of the reactor and a volume of liquid metal coolant at high temperature and a safety vessel around the main vessel, both vessels being suspended to a rigid upper slab kept at a lower temperature. It is mounted in the annular space between the two vessels and includes a neutral gas circuit set up between the wall of the main vessel to be cooled and that of the safety vessel itself cooled from outer. The neutral gas system comprises a plurality of ventilators fitted in holes made through the thickness of the upper slab and opening on to the space between the two vessels. It also includes two envelopes lining the walls of these vessels, establishing with them small section channels for the circulation of the neutral gas cooled against the safety vessel and heated against the main vessel [fr

  9. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    shunt HAPF, APF is connected in series with PPF and the whole system is connected in parallel to the load. ... LC filter, it will force a fundamental reactive current to flow into it. ..... Since SHAPF is operating as a boost rectifier, d.c. voltage.

  10. Cranial dural arteriovenous shunts. Part 4. Clinical presentation of the shunts with leptomeningeal venous drainage.

    Science.gov (United States)

    Baltsavias, Gerasimos; Spiessberger, Alex; Hothorn, Torsten; Valavanis, Anton

    2015-04-01

    course seems superfluous and possibly misleading. Topography is connected to the clinical presentation of the dural shunts inasmuch as the former determines the venous anatomy and the angioarchitectural features of the lesions.

  11. Pressurized water reactor fuel performance problems connected with fuel cladding corrosion processes

    International Nuclear Information System (INIS)

    Dobrevski, I.; Zaharieva, N.

    2008-01-01

    Generally, Pressurized Water Reactor (WWER, PWR) Fuel Element Performance is connected with fuel cladding corrosion and crud deposition processes. By transient to extended fuel cycles in nuclear power reactors, aiming to achieve higher burnup and better fuel utilization, the role of these processes increases significantly. This evolution modifies the chemical and electrochemical conditions in the reactor primary system, including change of fuel claddings' environment. The higher duty cores are always attended with increased boiling (sub-cooled nucleate boiling) mainly on the feed fuel assemblies. This boiling process on fuel cladding surfaces can cause different consequences on fuel element cladding's environment characteristics. In the case of boiling at the cladding surfaces without or with some cover of corrosion product deposition, the behavior of gases dissolved in water phase is strongly influenced by the vapor generation. The increase of vapor partial pressure will reduce the partial pressures of dissolved gases and will cause their stripping out. By these circumstances the concentrations of dissolved gases in cladding wall water layer can dramatically decrease, including also the case by which all dissolved gases to be stripped out. On the other hand it is known that the hydrogen is added to primary coolant in order to avoid the production of oxidants by radiolysis of water. It is clear that if boiling strips out dissolved hydrogen, the creation of oxidizing conditions at the cladding surfaces will be favored. In this case the local production of oxidants will be a result from local processes of water radiolysis, by which not only both oxygen (O 2 ) and hydrogen (H 2 ) but also hydrogen peroxide (H 2 O 2 ) will be produced. While these hydrogen and oxygen will be stripped out preferentially by boiling, the bigger part of hydrogen peroxide will remain in wall water phase and will act as the most important factor for creation of oxidizing conditions in fuel

  12. Creation of transcatheter aortopulmonary and cavopulmonary shunts using magnetic catheters: feasibility study in swine.

    Science.gov (United States)

    Levi, Daniel S; Danon, Saar; Gordon, Brent; Virdone, Nicky; Vinuela, Fernando; Shah, Sanjay; Carman, Greg; Moore, John W

    2009-05-01

    Surgical shunts are the basic form of palliation for many types of congenital heart disease. The Glenn shunt (superior cavopulmonary connection) and central shunt (aortopulmonary connection) represent surgical interventions that could potentially be accomplished by transcatheter techniques. We sought to investigate the efficacy of using neodymium iron boron (NdFeB) magnetic catheters to create transcatheter cavopulmonary and aortopulmonary shunts. NdFeB magnets were machined and integrated into catheters. "Target" catheters were placed in the pulmonary arteries (PAs), and radiofrequency "perforation" catheters were placed in either the descending aorta (DAo) for central shunts or the superior vena cava (SVC) for Glenn shunts. The magnet technique or "balloon target" method was used to pass wires from the DAo or the SVC into the PA. Aortopulmonary and cavopulmonary connections were then created using Atrium iCAST covered stents. Magnet catheters were used to perforate the left pulmonary artery from the DAo, thereby establishing a transcatheter central shunt. Given the orientation of the vasculature, magnetic catheters could not be used for SVC-to-PA connections; however, perforation from the SVC to the right pulmonary artery was accomplished with a trans-septal needle and balloon target. Transcatheter Glenn or central shunts were successfully created in four swine.

  13. Aqueous shunts for glaucoma.

    Science.gov (United States)

    Tseng, Victoria L; Coleman, Anne L; Chang, Melinda Y; Caprioli, Joseph

    2017-07-28

    Aqueous shunts are employed to control intraocular pressure (IOP) for people with primary or secondary glaucomas who fail or are not candidates for standard surgery. To assess the effectiveness and safety of aqueous shunts for reducing IOP in glaucoma compared with standard surgery, another type of aqueous shunt, or modification to the aqueous shunt procedure. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 8), MEDLINE Ovid (1946 to August 2016), Embase.com (1947 to August 2016), PubMed (1948 to August 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to August 2016), ClinicalTrials.gov (www.clinicaltrials.gov); searched 15 August 2016, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 15 August 2016. We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 15 August 2016. We also searched the reference lists of identified trial reports and the Science Citation Index to find additional trials. We included randomized controlled trials that compared various types of aqueous shunts with standard surgery or to each other in eyes with glaucoma. Two review authors independently screened search results for eligibility, assessed the risk of bias, and extracted data from included trials. We contacted trial investigators when data were unclear or not reported. We graded the certainty of the evidence using the GRADE approach. We followed standard methods as recommended by Cochrane. We included 27 trials with a total of 2099 participants with mixed diagnoses and comparisons of interventions. Seventeen studies reported adequate methods of randomization, and seven reported adequate allocation concealment. Data collection and follow-up times varied.Four trials compared an aqueous shunt (Ahmed or Baerveldt) with trabeculectomy, of which

  14. Decommissioning of the research nuclear reactor IRT-M and problems connected with radioactive waste

    International Nuclear Information System (INIS)

    Abramidze, S.P.; Katamadze, N.M.; Kiknadze, G.G.; Saralidze, Z.K.

    2000-01-01

    The nuclear research reactor IRT-2000 is described, along with modifications and upgrades made over the past three decades. Considerations are outlined which followed a decision to shut-down the reactor and to dismantle it. (author)

  15. Ventriculoperitoneal shunt infections in children

    African Journals Online (AJOL)

    1991-02-02

    Feb 2, 1991 ... shunts: epidemiology, clinical manifestations and therapy.] Infecr Vis 1975;. 13: 543-552. 4. Odio C, McCracken GH jun, Nelson JD. CSF shunt infections in pediatrics, a seven-year experience. Am] Dis Child 1984; 138: 1103-1108. 5. Meirovitch J, Kitai-Cohen Y, Keren G, Fiendler G, Rubinstein E. Cerebro-.

  16. Congenital extrahepatic portosystemic shunts

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S. [Department of Diagnostic Imaging, Hospital for Sick Children, 555 University Avenue, M5G 1X8, Toronto, Ontario (Canada)

    2003-09-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  17. Congenital extrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S.

    2003-01-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  18. The probable types, sizes, positions and orientations of the defects which may appear in connection with manufacture of reactor vessels

    International Nuclear Information System (INIS)

    Bergh, S.

    1980-02-01

    An review of welding technology in manufacture of reactor vessels is made. An inventory of principal defects appearing in connection with manual ARC-welding and coated electrodes is presented. Some important welded joints of BWR reactor vessels are scrutinized. Reheating cracks may appear during stress relief annealing beneath the cladding, and this problem is discussed in the third part. The interest is focussed towards the defects which depend on the conditions during the welding. Slag and incomplete fusion might be found. The review can serve for the guidance of nondestructive testing. The defects are estimated to have the size of a few MM with a maximum to approx. 10 MM right across the weld, possibly with exception for the electroslag welds of the OKG-1 reactor vessel. (GBn)

  19. The Texts of the Instruments connected with the Agency's Assistance to Finland in Establishing a Research Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-01-24

    The texts of the Supply Agreement between the Agency, the Government of Finland and the Government of the United States of America, and of the Project Agreement between the Agency and the Government of Finland, in connection with the Agency's assistance to the Government of Finland in establishing a research reactor project, are reproduced in this document for the information of all Members of the Agency. These agreements entered into force on 30 December 1960.

  20. The Texts of the Instruments connected with the Agency's Assistance to Pakistan in Establishing a Research Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1962-03-22

    The texts of the Supply Agreement between the Agency, the Government of Pakistan and the Government of the United States of America, and of the Project Agreement between the Agency and the Government of Pakistan, in connection with the Agency's assistance to the Government of Pakistan-in establishing a research reactor project, are reproduced in this document for the information of all Members of the Agency. These Agreements entered into force on 5 March 1962.

  1. The Texts of the Instruments connected with the Agency's Assistance to Yugoslavia in Establishing a Research Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-11-24

    The texts of the Supply Agreement between the Agency, the Government of Yugoslavia and the Government of the United States of America, and of the Project Agreement between the Agency and the Government of Yugoslavia, in connection with the Agency's assistance to the Government of Yugoslavia in establishing a research reactor project, are reproduced in this document for the information of all Members of the Agency. These Agreements entered into force on 4 October 1961.

  2. The Texts of the Instruments connected with the Agency's Assistance to Mexico in Establishing a Research Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1964-01-30

    The texts of the Supply Agreement between the Agency and the Governments of Mexico and the United States of America, and of the Project Agreement between the Agency and the Government of Mexico, in connection with the Agency's assistance to that Government in establishing a research reactor project, are reproduced in this document for the information of all Members. These Agreements entered into force on 18 December 1963.

  3. The Texts of the Instruments connected with the Agency's Assistance to Iran in Establishing a Research Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1967-08-31

    The texts of the Supply Agreement between the Agency and the Governments of Iran and the United States of America, and of the Project Agreement between the Agency and the Government of Iran, connected with the Agency's assistance to the latter Government in establishing a research reactor project, are reproduced in this document for the information of all Members. The Agreements entered into force on 7 June and 10 May 1967 respectively.

  4. The Texts of the Instruments connected with the Agency's assistance to Uruguay in Establishing a Research Reactor Project

    International Nuclear Information System (INIS)

    1965-01-01

    The texts of the Supply Agreement between the Agency and the Governments of the United States of America and Uruguay, and of the Project Agreement between the Agency and the Government of Uruguay, in connection with the Agency's assistance to the latter Government in establishing a research reactor project, are reproduced in this document for the information of all Members. These Agreements entered into force on 24 September 1965

  5. The Texts of the Instruments connected with the Agency's assistance to Uruguay in Establishing a Research Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1965-12-09

    The texts of the Supply Agreement between the Agency and the Governments of the United States of America and Uruguay, and of the Project Agreement between the Agency and the Government of Uruguay, in connection with the Agency's assistance to the latter Government in establishing a research reactor project, are reproduced in this document for the information of all Members. These Agreements entered into force on 24 September 1965.

  6. The Texts of the Instruments connected with the Agency's Assistance to Pakistan in Establishing a Research Reactor Project

    International Nuclear Information System (INIS)

    1962-01-01

    The texts of the Supply Agreement between the Agency, the Government of Pakistan and the Government of the United States of America, and of the Project Agreement between the Agency and the Government of Pakistan, in connection with the Agency's assistance to the Government of Pakistan-in establishing a research reactor project, are reproduced in this document for the information of all Members of the Agency. These Agreements entered into force on 5 March 1962

  7. The Texts of the Instruments connected with the Agency's Assistance to Finland in Establishing a Research Reactor Project

    International Nuclear Information System (INIS)

    1961-01-01

    The texts of the Supply Agreement between the Agency, the Government of Finland and the Government of the United States of America, and of the Project Agreement between the Agency and the Government of Finland, in connection with the Agency's assistance to the Government of Finland in establishing a research reactor project, are reproduced in this document for the information of all Members of the Agency. These agreements entered into force on 30 December 1960

  8. The Texts of the Instruments connected with the Agency's Assistance to Iran in Establishing a Research Reactor Project

    International Nuclear Information System (INIS)

    1967-01-01

    The texts of the Supply Agreement between the Agency and the Governments of Iran and the United States of America, and of the Project Agreement between the Agency and the Government of Iran, connected with the Agency's assistance to the latter Government in establishing a research reactor project, are reproduced in this document for the information of all Members. The Agreements entered into force on 7 June and 10 May 1967 respectively

  9. The Texts of the Instruments connected with the Agency's Assistance to Yugoslavia in Establishing a Research Reactor Project

    International Nuclear Information System (INIS)

    1961-01-01

    The texts of the Supply Agreement between the Agency, the Government of Yugoslavia and the Government of the United States of America, and of the Project Agreement between the Agency and the Government of Yugoslavia, in connection with the Agency's assistance to the Government of Yugoslavia in establishing a research reactor project, are reproduced in this document for the information of all Members of the Agency. These Agreements entered into force on 4 October 1961

  10. The Texts of the Instruments connected with the Agency's Assistance to Mexico in Establishing a Research Reactor Project

    International Nuclear Information System (INIS)

    1964-01-01

    The texts of the Supply Agreement between the Agency and the Governments of Mexico and the United States of America, and of the Project Agreement between the Agency and the Government of Mexico, in connection with the Agency's assistance to that Government in establishing a research reactor project, are reproduced in this document for the information of all Members. These Agreements entered into force on 18 December 1963

  11. Subacute bacterial endocarditis and subsequent shunt nephritis from ventriculoatrial shunting 14 years after shunt implantation

    DEFF Research Database (Denmark)

    Burström, Gustav; Andresen, Morten; Bartek, Jiri Jr.

    2014-01-01

    of causing subacute bacterial endocarditis and subsequent shunt nephritis. The patient was successfully treated with antibiotics combined with ventriculoatrial shunt removal and endoscopic third ventriculocisternostomy (VCS). This case illustrates the nowadays rare, but potentially severe complication...... of subacute bacterial endocarditis and shunt nephritis. It also exemplifies the VCS as an alternative to implanting foreign shunt systems for CSF diversion....

  12. Single-phase AutoReClosure ARC failure on 400 kV combinedcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    400 kV power system and initiated by Danish TSO Energinet.dk after having measured the voltage of the cable/overhead line after disconnection. A particular decaying dynamic phase voltage containing voltages higher than the voltage before disconnection appeared. A simulation model for the entire system...

  13. Design and testing of reactors for 735 kV

    Energy Technology Data Exchange (ETDEWEB)

    Erb, W; Kraaij, D J

    1965-11-01

    The design and testing of five large, single phase shunt reactors rated either 110 or 55 MVAR, supplied for the 735 kV system of the Quebec Hydro Electric Commission which came into operation in the autumn of 1965 are described. As these reactors are permanently connected to the transmission lines, their losses must be considered as being continuously present and must be determined exactly. In addition to the use of a new bridge method, the losses were also measured calorimetrically for the purpose of comparison, the agreement between the two tests being remarkably good. The impulse tests with full wave and chopped wave are subsequently described.

  14. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.-D.

    1996-05-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole, and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors, and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model

  15. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.

    1997-01-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model. copyright 1997 American Institute of Physics

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Intrahepatic Portosystemic Shunt (TIPS)? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  19. Status of October 1, 2004 of the repartition of nuclear reactors connected to the grid and under construction in the world

    International Nuclear Information System (INIS)

    2004-01-01

    This document is a table giving the number of nuclear reactors connected to the grid and under construction in the European countries and in the rest of the world. The percentage of electricity produced by these reactors in 2003 is indicated. (J.S.)

  20. Magnetic switch for reactor control rod

    International Nuclear Information System (INIS)

    Germer, J.H.

    1986-01-01

    This patent describes a control rod system for a nuclear reactor utilizing an electromagnetic grapple mechanism for holding and releasing a control rod, the improvement comprising a magnetic reed switch assembly having a Curie-point magnetic shunt and responsive to reactor coolant temperature for short circuiting the electromagnetic grapple mechanism causing release of the control rod when the coolant temperature reaches the Curie-point of the magnetic shunt. The magnetic reed switch assembly includes a: a permanent magnet, a pair of magnetic pole pieces located at and in contact with opposite ends of the permanent magnet, the Curie-point magnetic shunt being positioned adjacent the permanent magnet and in contact with the pair of magnetic pole pieces, and a reed switch positioned intermediate the pole pieces and provided with a pair of ferromagnetic reeds, a nonmagnetic enclosure around the reeds, a first of the reeds being secured at one end to a first of the pair of pole pieces, a second of the reeds having one end extending into and secured to a hollow member positioned in and extending through a second of the pair of pole pieces, the one end of the second of the reeds secured to a condector adapted to be connected to the electromagnetic grapple mechanism

  1. Failed Ventriculoperitoneal Shunt: Is Retrograde Ventriculosinus Shunt a Reliable Option?

    Science.gov (United States)

    Oliveira, Matheus Fernandes de; Teixeira, Manoel Jacobsen; Reis, Rodolfo Casimiro; Petitto, Carlo Emanuel; Gomes Pinto, Fernando Campos

    2016-08-01

    Currently, the treatment of hydrocephalus is mainly carried out through a ventriculoperitoneal shunt (VPS) insertion. However, in some cases, there may be surgical revisions and requirement of an alternative distal site for shunting. There are several described distal sites, and secondary options after VPS include ventriculopleural and ventriculoatrial shunt, which have technical difficulties and harmful complications. In this preliminary report we describe our initial experience with retrograde ventriculosinus shunt (RVSS) after failed VPS. In 3 consecutive cases we applied RVSS to treat hydrocephalus in shunt-dependent patients who had previously undergone VPS revision and in which peritoneal space was full of adhesions and fibrosis. RVSS was performed as described by Shafei et al., with some modifications to each case. All 3 patients kept the same clinical profile after RVSS, with no perioperative or postoperative complications. However, revision surgery was performed in the first operative day in 1 out of 3 patients, in which the catheter was not positioned in the superior sagittal sinus. We propose that in cases where VPS is not feasible, RVSS may be a safe and applicable second option. Nevertheless, the long-term follow-up of patients and further learning curve must bring stronger evidence. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Two design aspects connected with the safety of the PIK reactor presently under construction

    International Nuclear Information System (INIS)

    Gostev, V.V.; Zakharov, A.S.; Konoplev, K.A.; Levandovskii, N.V.; Ploshchanskii, L.M.; Smolsky, S.L.

    1993-01-01

    The PIK reactor is designed for physical research with neutron beams and sample irradiation. In the central trap the thermal neutrons flux is 4x10 15 n/cm 2 s. The reactor power is 100 MW, the thermal neutron flux in the reflector at the maximum of distribution is 1x10 15 n/cm 2 s. The core with a high uranium concentration of 600 g/l is light water-cooled, heavy water being used in the reflector. The Chernobyl disaster happened at the time of equipment installation at the PIK. The code revision, a change of the authors ideas about the safety, and a change of public attitude towards nuclear installations resulted in a stopping of construction and project revision. Reconstruction project has led to a change of all safety systems and involved in various degrees all essential reactor systems. The construction is presently resumed in spite of economic difficulties in Russia. The reactor was inspected by experts from a number of European countries, USA, and European Commission delegated by their governments to prepare a report on whether supporting the construction to its completion would be reasonable. In the course of inspection the experts from USA and EU expressed doubts concerning two systems, namely, the containment and scram. These two points are discussed in the present paper. Three type of containments are proposed and an analysis of their efficiency is presented. The PIK reactor is controlled by eight rods in the heavy-water reflector -and an absorbing cylinder at the boundary between the core and the central light-water neutron trap. The rods are used for emergency protection and reactor start-up. The central control cylinder called here the shutter serves several functions, namely, as scram, automatic control, and burnup compensation. The delay time before the onset of negative reactivity is 1.05 sec for rods and 0.25 sec for the shutter

  3. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  4. Performance analysis of a simple shunt and series compensated six-phase self-excited induction generator for stand-alone renewable energy generation

    International Nuclear Information System (INIS)

    Singh, G.K.; Kumar, A. Senthil; Saini, R.P.

    2011-01-01

    This paper describes a new generalized and efficient model for performance analysis of a six-phase self-excited induction generator (SPSEIG) with three capacitor excitation topologies; simple shunt, short shunt and long shunt. Mathematical model of SPSEIG is formulated using nodal admittance method based on graph theory. Attention is focused on the influence of the different capacitor connections on the generator overload and output power capabilities. The generator voltage with simple shunt excitation connection collapses when it is overloaded while with either the short shunt or long shunt excitation connection; generator is able to sustain the load at a lower operating voltage and larger load current. The matrix equation developed by nodal admittance method is solved by Genetic Algorithm (GA) technique to predetermine the steady-state performance of SPSEIG. The experimental and theoretical results are found to be in good agreement.

  5. Ventriculoperitoneal shunt blockage by hydatid cyst

    Directory of Open Access Journals (Sweden)

    Abrar A Wani

    2013-01-01

    Full Text Available Ventriculoperitoneal (VP shunt is one of the commonest procedures done in neurosurgical practice throughout the world. One of the commonest problems after putting the VP shunt is the shunt obstruction, which can be due to varied causes. Shunt obstruction secondary to the parasitic infections is rarely seen. We are presenting a 15-year-old child, a case of operated cerebral hydatid cyst with hydrocephalus. She presented with shunt malfunction after 1 year of surgical excision of the hydatid cyst. Revision of the VP shunt was done and peroperatively, it was found that the shunt tubing was obstructed due to small hydatid cysts. This is the first reported case of VP shunt obstruction by hydatid cyst.

  6. Congenital hepatic arteriovenous fistula with intrahepatic portosystemic shunt and aortic stenosis in a dog

    International Nuclear Information System (INIS)

    Koide, K.; Koide, Y.; Wada, Y.; Nakaniwa, S.; Yamane, Y.

    2004-01-01

    Examination of a 2-month-old male golden retriever presented to the hospital revealed malnutrition, ascites, cardiac murmur and hyperammonemia. Identification of subaortic stenosis and hepatic arteriovenous fistula was made through ultrasonography and angiocardiography. In addition, intrasurgical mesenteric portography showed an intrahepatic portosystemic shunt. The dog did not show portal hypertension and secondary multiple extrahepatic portosystemic shunts. Surgical correction was attempted after medical treatment. The hepatic artery branch which was connected to the hepatic arteriovenous fistula was separated, and completely ligated using silk ligature. However, the separation of the intrahepatic shunt blood vessel was unsuccessful and the dog died 15 hr postoperatively

  7. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Kyu, E-mail: power@changwon.ac.kr [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Kim, Kwangmin; Park, Minwon [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Lee, Sangjin [Uiduk University, Gyeongju 780-713 (Korea, Republic of)

    2015-11-15

    Highlights: • A 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC transmission system. • The 400 mH class HTS DC reactor was connected to real power network via the HVDC system. • The DC current flowed in HTS DC reactor has several harmonic components and it was analyzed using FFT. - Abstract: High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  8. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    International Nuclear Information System (INIS)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-01-01

    Highlights: • A 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC transmission system. • The 400 mH class HTS DC reactor was connected to real power network via the HVDC system. • The DC current flowed in HTS DC reactor has several harmonic components and it was analyzed using FFT. - Abstract: High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  9. A nuclear reactor core fuel reload optimization using Artificial-Ant-Colony Connective Networks

    International Nuclear Information System (INIS)

    Lima, Alan M.M. de; Schirru, Roberto

    2005-01-01

    A Pressurized Water Reactor core must be reloaded every time the fuel burnup reaches a level when it is not possible to sustain nominal power operation. The nuclear core fuel reload optimization consists in finding a burned-up and fresh-fuel-assembly pattern that maximizes the number of full operational days. This problem is NP-hard, meaning that complexity grows exponentially with the number of fuel assemblies in the core. Besides that, the problem is non-linear and its search space is highly discontinual and multimodal. In this work a parallel computational system based on Ant Colony System (ACS) called Artificial-Ant-Colony Networks is introduced to solve the nuclear reactor core fuel reload optimization problem. ACS is a system based on artificial agents that uses the reinforcement learning technique and was originally developed to solve the Traveling Salesman Problem, which is conceptually similar to the nuclear fuel reload problem. (author)

  10. Parallel connecting poloidal coil system for a doublet tokamak fusion reactor

    International Nuclear Information System (INIS)

    Toffolo, W.E.; Chen, W.Y.; Purcell, J.R.; Wesley, J.C.

    1977-09-01

    A method has been developed for parallel connection of the ohmic heating (OH) coil. The method involves subdividing the OH-coil into a number of parallel connected subcoils, with each subcoil having about 20 turns. Each of the field shaping coils (F-coils) also contains 20 turns, so that when connected to a common power supply, the OH and F-coils are decoupled. The advantages resulting from the scheme are numerous: (1) each F-coil contains a much smaller number of turns compared with the previous design concept, thus the construction and maintenance will be easier; (2) the parallel connected OH-coils form a constant flux envelope, resulting in an inherently lower error field at the plasma and the TF coil region, and this low error field is not sensitive to the variation in location of the OH-coils; (3) the voltage and current ratings of the individual OH coil conductors are reduced; and (4) the low impedance of the OH-coil system greatly improves the possibility of using a homopolar motor generator as a means of achieving flux reversal during startup and plasma current control during the burn cycle

  11. Experimental Study of Thermal Crisis in Connection with Tokamak Reactor High Heat Flux Components

    International Nuclear Information System (INIS)

    Gallo, D.; Giardina, M.; Castiglia, F.; Celata, G.P.; Mariani, A.; Zummo, G.; Cumo, M.

    2000-01-01

    The results of an experimental research on high heat flux thermal crisis in forced convective subcooled water flow, under operative conditions of interest to the thermal-hydraulic design of TOKAMAK fusion reactors, are here reported. These experiments, carried out in the framework of a collaboration between the Nuclear Engineering Department of Palermo University and the National Institute of Thermal - Fluid Dynamics of the ENEA - Casaccia (Rome), were performed on the STAF (Scambio Termico Alti Flussi) water loop and consisted, essentially, in a high speed photographic study which enabled focusing several information on bubble characteristics and flow patterns taking place during the burnout phenomenology

  12. Muzzle shunt augmentation of conventional railguns

    International Nuclear Information System (INIS)

    Parker, J.V.

    1991-01-01

    This paper reports on augmentation which is a technique for reducing the armature current and hence the armature power dissipation in a plasma armature railgun. In spite of the advantages, no large augmented railguns have been built, primarily due to the mechanical and electrical complexity introduced by the extra conductors required. it is possible to achieve some of the benefits of augmentation in a conventional railgun by diverting a fraction φ of the input current through a shunt path at the muzzle of the railgun. In particular, the relation between force and armature current is the same as that obtained in an n-turn, series-connected augmented railgun with n = 1/(1 - φ). The price of this simplification is a reduction in electrical efficiency and some additional complexity in the external electrical system

  13. Determination of blood flow through arteriovenous fistulae and shunts

    International Nuclear Information System (INIS)

    Lantz, B.M.T.; Holcroft, J.W.; Foerster, J.M.; Link, D.P.; Reid, M.H.

    1979-01-01

    A videodensitometric method for estimating relative flow was employed in a patient with a bovine arteriovenous fistula. Analogous arteriovenous communications of different sizes were created in two dogs for comparison. Local and general hemodynamic parameters were measured. The videodensitometric method proved to be highly accurate compared to electromagnetic flow readings and is the method of choice in estimating shunt flow in connection with routine angiography. (Auth.)

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Transjugular Intrahepatic Portosystemic Shunt ( ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Portosystemic Shunt (TIPS) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  16. A nuclear reactor core fuel reload optimization using artificial ant colony connective networks

    International Nuclear Information System (INIS)

    Lima, Alan M.M. de; Schirru, Roberto; Carvalho da Silva, Fernando; Medeiros, Jose Antonio Carlos Canedo

    2008-01-01

    The core of a nuclear Pressurized Water Reactor (PWR) may be reloaded every time the fuel burn-up is such that it is not more possible to maintain the reactor operating at nominal power. The nuclear core fuel reload optimization problem consists in finding a pattern of burned-up and fresh-fuel assemblies that maximize the number of full operational days. This is an NP-Hard problem, meaning that complexity grows exponentially with the number of fuel assemblies in the core. Moreover, the problem is non-linear and its search space is highly discontinuous and multi-modal. Ant Colony System (ACS) is an optimization algorithm based on artificial ants that uses the reinforcement learning technique. The ACS was originally developed to solve the Traveling Salesman Problem (TSP), which is conceptually similar to the nuclear core fuel reload problem. In this work a parallel computational system based on the ACS, called Artificial Ant Colony Networks is introduced to solve the core fuel reload optimization problem

  17. A nuclear reactor core fuel reload optimization using artificial ant colony connective networks

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Alan M.M. de [Universidade Federal do Rio de Janeiro, PEN/COPPE - UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: alanmmlima@yahoo.com.br; Schirru, Roberto [Universidade Federal do Rio de Janeiro, PEN/COPPE - UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: schirru@lmp.ufrj.br; Carvalho da Silva, Fernando [Universidade Federal do Rio de Janeiro, PEN/COPPE - UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: fernando@con.ufrj.br; Medeiros, Jose Antonio Carlos Canedo [Universidade Federal do Rio de Janeiro, PEN/COPPE - UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: canedo@lmp.ufrj.br

    2008-09-15

    The core of a nuclear Pressurized Water Reactor (PWR) may be reloaded every time the fuel burn-up is such that it is not more possible to maintain the reactor operating at nominal power. The nuclear core fuel reload optimization problem consists in finding a pattern of burned-up and fresh-fuel assemblies that maximize the number of full operational days. This is an NP-Hard problem, meaning that complexity grows exponentially with the number of fuel assemblies in the core. Moreover, the problem is non-linear and its search space is highly discontinuous and multi-modal. Ant Colony System (ACS) is an optimization algorithm based on artificial ants that uses the reinforcement learning technique. The ACS was originally developed to solve the Traveling Salesman Problem (TSP), which is conceptually similar to the nuclear core fuel reload problem. In this work a parallel computational system based on the ACS, called Artificial Ant Colony Networks is introduced to solve the core fuel reload optimization problem.

  18. Investigation of the deposit formation in pipelines connecting liquefaction reactors; 1t/d PSU ni okeru ekika hanno tokan fuchakubutsu no seisei yoin ni kansuru ichikosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Y.; Nogami, Y.; Inokuchi, K. [Mitsui SRC Development Co. Ltd., Tokyo (Japan); Mochizuki, M.; Imada, K. [Nippon Steel Corp., Tokyo (Japan)

    1996-10-28

    The liquefaction reaction system of an NEDOL process coal liquefaction 1t/d PSU was opened and checked to investigate the cause of the rise of differential pressure between liquefaction reactors of the PSU. The liquefaction test at a coal concentration of 50 wt% using Tanito Harum coal was conducted, and it was found that the differential pressure between reactors was on the increase. By the two-phase flow pressure loss method, deposition thickness of deposit in pipelines was estimated at 4.4mm at the time of end operation, which agreed with a measuring value obtained from a {gamma} ray. The rise of differential pressure was caused by deposit formation in pipelines connecting reactors. The main component of the deposit is calcite (CaCO3 60-70%) and is the same as the usual one. It is also the same type as the deposit on the reactor wall. Ca in coal ash is concerned with this. To withdraw solid matters deposited in the reactor, there are installed pipelines for the withdrawal at the reactor bottom. The solid matters are regularly purged by reverse gas for prevention of clogging. As the frequency of purge increases, the deposit at the reactor bottom decreases, but the deposit attaches strongly to pipelines connecting reactors. It is presumed that this deposit is what Ca to be discharged out of the system as a form of deposition solid matter naturally in the Ca balance precipitated as calcite in the pipeline connecting the reactor. 3 refs., 5 figs., 4 tabs.

  19. Reactor

    International Nuclear Information System (INIS)

    Ikeda, Masaomi; Kashimura, Kazuo; Inoue, Kazuyuki; Nishioka, Kazuya.

    1979-01-01

    Purpose: To facilitate the construction of a reactor containment building, whereby the inspections of the outer wall of a reactor container after the completion of the construction of the reactor building can be easily carried out. Constitution: In a reactor accommodated in a container encircled by a building wall, a space is provided between the container and the building wall encircling the container, and a metal wall is provided in the space so that it is fitted in the building wall in an attachable or detatchable manner. (Aizawa, K.)

  20. Ventriculo-pleural shunt patency study

    International Nuclear Information System (INIS)

    Yeates, K.

    2000-01-01

    Full text: A twenty-four year old male was admitted to hospital complaining of headaches, drowsiness and blurred vision. He suffered from congenital hydrocephalus and had had a ventriculo-peritoneal shunt inserted in infancy. This had undergone many revisions due to persistent peritoneal infections and had recently been replaced with a ventriculo-pleural shunt. The symptoms described suggested shunt blockage and he was referred for a Shunt Patency Study. The current shunt is a HAKIM Programmable Valve Shunt System and the opening pressure was 12cm of CSF (within the normal range). Forty megabecquerels of filtered 99 Tc m O 4 was injected into the pre-chamber of the shunt. Serial images and counts were obtained for twenty-five minutes after the injection. The images showed the tracer flowing from the shunt within the first ten minutes. At twenty minutes almost all of the tracer had drained from the shunt and was present in the right pleural cavity, indicating shunt patency. This study is presented to demonstrate the appearances of a normally functioning, but rarely seen Ventriculo-Pleural CSF Shunt. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  1. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    Science.gov (United States)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-11-01

    High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  2. Shunts to divert aqueous humor to distant epithelialized cavities after keratoprosthesis surgery.

    Science.gov (United States)

    Dohlman, Claes H; Grosskreutz, Cynthia L; Chen, Teresa C; Pasquale, Louis R; Rubin, Peter A D; Kim, Eva C; Durand, Marlene

    2010-02-01

    Glaucoma is a frequent and often severe problem in patients needing keratoprosthesis (KPro) surgery. Standard glaucoma shunts in these cases often develop a very dense capsule that obstructs flow and causes intraocular pressure elevation. Therefore, we developed shunts that deliver aqueous to distant epithelialized cavities where an obstructing capsule is less likely to form. In this retroactive study of such shunts, the risk of postoperative infection (especially endophthalmitis) has been assessed. Ahmed shunts were connected with a tube to the lacrimal sac or ethmoid sinuses. In subsequent designs the polypropylene plate was eliminated, the valve was enclosed and a distal tube added (New World Medical Inc, Rancho Cucamonga, CA). The latter shunts were connected to the maxillary sinus or lower lid fornix. Between 2001 and 2005 the devices were implanted in 34 patients with very severe ocular disease. (31 had KPro implanted). Thus, the distal tube was led to the lacrimal sac (2 cases), to the ethmoid sinuses (6), to the maxillary sinus (16 cases), and to the lower lid fornix (10 cases). The patients were followed for cumulatively 145 shunt years, with a mean follow-up of 4 years and 3 months. They were instructed to administer low-dose topical antibiotics indefinitely. Only 1 case of acute bacterial endophthalmitis occurred, thus an incidence of 0.7% per shunt year. A slow-growing Mycobacterium was cultured in a disintegrating eye and 1 bacterial maxillary sinusitis occurred, both in autoimmune diseases. Three valves became exposed and had to be removed (1 replaced). Four eyes developed hypotony, probably from valve failure. The shunt arrangement, which connects the anterior chamber to potentially microbe-populated cavities or to the lower lid fornix and its flora, might be suspected to allow rapid retrograde invasion of infective agents, resulting in endophthalmitis. In this series of KPro patients, however, the incidence of severe infection was very low, in fact

  3. [Extracorporeal ventriculoatrial shunt with the use of one-way ball valve].

    Science.gov (United States)

    Kubo, Shigeki; Takimoto, Hiroshi; Hosoi, Kazuki; Toyota, Shingo; Takakura, Shuji; Hayashi, Yasuhiro; Ueno, Masato; Morisako, Toshitaka; Karasawa, Jun; Ninaga, Hideo; Yoshimine, Toshiki

    2002-04-01

    We developed a simple system of an "extracorporeal" ventriculoatrial (VA) shunt using a one-way ball valve (Acty valve II, Kaneka Medix) to release the patient from postoperative constraint during the ventricular drainage. The system is constructed in such a way that the ventricular drainage tube is connected to the central venous catheter via a one-way valve. The CSF is regulated by using the valve and is diverted into the systemic circulation as in the conventional ventriculoatrial shunt. After 2 or 3 weeks of CSF diversion through the extracorporeal VA shunt, a ventriculoperitoneal shunt is placed if hydrocephalus is apparent by temporary occlusion of the system. We applied this system to 4 patients with hydrocephalus, and we found it useful and free from adverse effects. The patient was freed from physical constraint involved in conventional ventricular drainage and an effective program of early rehabilitation was able to be started.

  4. Simulation and Hardware Implementation of Shunt Active Power Filter Based on Synchronous Reference Frame Theory

    Directory of Open Access Journals (Sweden)

    Karthikrjan Senthilnathan

    2018-02-01

    Full Text Available This paper describes about the Hybrid Shunt Active Power Filter (HSAPF for the elimination of the current harmonics in the line side of the three phase three wire systems. The Active Power Filter is based on the Voltage Source Converter (VSC topology. The control strategy for the converter is based on Synchronous Reference Frame (SRF theory. The compensation of harmonics is done by the APF which is connected in the shunt configuration to the system. The Shunt APF has the better compensation of current harmonics. The design and implementation of Shunt active power filter is done by MATLAB/Simulink. The real time implementation by using the ATMEGA 8 Microcontroller. The Simulation and Hardware results shows that the current harmonics are eliminated in the system

  5. The Texts of the Instruments connected with the Agency's Assistance to the Democratic Republic of the Congo in Continuing a Research Reactor Project Project. Extension Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-11-18

    The text of the Project Extension Agreement between the Agency and the Government of the Democratic Republic of the Congo in connection with the Agency's additional assistance to that Government in continuing a research reactor project is reproduced in this document for the information of all Members. This Agreement entered into force on 27 September 1966.

  6. The Texts of the Instruments connected with the Agency's Assistance to Finland in relation to a Research Reactor Project. A Fourth Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1970-02-05

    As a sequel to the assistance which the Agency provided to the Government of Finland in connection with a research reactor project, a fourth Supply Agreement has been concluded between the Agency and the Governments of Finland and the United States of America. This Agreement entered into force on 27 November 1969, and the text is reproduced herein for the information of all Members.

  7. The Texts of the Instruments connected with the Agency's Assistance to Finland in relation to a Research Reactor Project. A Third Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1968-01-12

    As a sequel to the assistance which the Agency provided to the Government of Finland in connection with a research reactor project), a third Supply Agreement has been concluded between the Agency and the Governments of Finland and the United States of America. This Agreement entered into force on 5 November 1967, and the text) is reproduced herein for the information of all Members.

  8. The Texts of the Instruments connected with the Agency's Assistance to Yugoslavia in Establishing a Research Reactor Project. Third Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1971-03-11

    As a sequel to the assistance which the Agency provided to the Government of Yugoslavia in connection with a research reactor project, a third Supply Agreement has been concluded between the Agency and the Governments of the United States of America and Yugoslavia. This Agreement entered into force on 30 December 1970, and the text is reproduced herein for the information of all Members.

  9. The Texts of the Instruments connected with the Agency's Assistance to Finland in relation to a Research Reactor Project. A Third Supply Agreement

    International Nuclear Information System (INIS)

    1968-01-01

    As a sequel to the assistance which the Agency provided to the Government of Finland in connection with a research reactor project), a third Supply Agreement has been concluded between the Agency and the Governments of Finland and the United States of America. This Agreement entered into force on 5 November 1967, and the text) is reproduced herein for the information of all Members

  10. The Texts of the Instruments connected with the Agency's Assistance to Yugoslavia in Establishing a Research Reactor Project. Third Supply Agreement

    International Nuclear Information System (INIS)

    1971-01-01

    As a sequel to the assistance which the Agency provided to the Government of Yugoslavia in connection with a research reactor project, a third Supply Agreement has been concluded between the Agency and the Governments of the United States of America and Yugoslavia. This Agreement entered into force on 30 December 1970, and the text is reproduced herein for the information of all Members

  11. The Texts of the Instruments connected with the Agency's Assistance to Finland in relation to a Research Reactor Project. A Fourth Supply Agreement

    International Nuclear Information System (INIS)

    1970-01-01

    As a sequel to the assistance which the Agency provided to the Government of Finland in connection with a research reactor project, a fourth Supply Agreement has been concluded between the Agency and the Governments of Finland and the United States of America. This Agreement entered into force on 27 November 1969, and the text is reproduced herein for the information of all Members

  12. Pediatric ventriculoperitoneal shunts and their complications: An analysis

    Directory of Open Access Journals (Sweden)

    Nitin Agarwal

    2017-01-01

    Conclusion: With this retrospective review of complications of VP shunts, age at initial shunt insertion and the interval between the age of initial shunt placement and onset of complications were the most important patient-related predictors of shunt failure. The different predominant etiological factors responsible for early and late shunt failure were infective and mechanical complications, respectively.

  13. A wireless monitoring system for Hydrocephalus shunts.

    Science.gov (United States)

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  14. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  15. The somatic shunt cable model for neurons.

    OpenAIRE

    Durand, D

    1984-01-01

    The derivation of the equations for an electrical model of nerve cells is presented. The model consists of an equivalent cylinder, a lumped somatic impedance, and a variable shunt at the soma. This shunt was introduced to take into account the fast voltage decays observed following the injections of current pulses in some motoneurons and hippocampal granule cells that could not be explained by existing models. The shunt can be interpreted either by penetration damage with the electrode or by ...

  16. A method for emergency flooding of the gland in the main circulating pump of pressurized water reactors and the connection therefor

    International Nuclear Information System (INIS)

    Skalicky, A.

    1978-01-01

    A method is described for the emergency flooding of the main circulating pumps of a pressurized water reactor such that in pressure drop in the flooded gland owing to pump suction, the pump head is connected by the pressure difference action to the flooding gland pipe, this via the heat sink and the filter of the emergency flooding circuit connected to the pump head. The emergency flooding circuit consisting of a pressure reducing valve, a check valve and a stop valve is connected to the pump head, behind the heat sink and the filter. The pressure reducing valve separates two pressure spaces. The former is connected to the pump head via the check valve and to the flooding pipe via the stop valve and the check valve. The latter is connected to the suction pump. (B.S.)

  17. Electron microscopic evaluation of a gold glaucoma micro shunt after explantation.

    Science.gov (United States)

    Berk, Thomas A; Tam, Diamond Y; Werner, Liliana; Mamalis, Nick; Ahmed, Iqbal Ike K

    2015-03-01

    We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Shunt protection for superconducting Maglev magnets

    Energy Technology Data Exchange (ETDEWEB)

    Atherton, D L [Queen' s Univ., Kingston, Ontario (Canada). Dept. of Physics

    1979-09-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated.

  19. Shunt protection for superconducting Maglev magnets

    International Nuclear Information System (INIS)

    Atherton, D.L.

    1979-01-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated. (author)

  20. MR imaging of syringoperitoneal and syringosubarachnoid shunts

    International Nuclear Information System (INIS)

    Hasso, A.N.; Kucharczyk, W.; Mall, J.C.; Colombo, N.; Newton, T.H.; Norman, D.

    1986-01-01

    The authors utilized MR imaging for the evaluation of syringohydromelic shunt procedures in 16 patients. Four characteristic MR imaging findings were seen: ''tethering'' of the spinal cord posteriorly at the site of laminectomy and placement of the shunt tube distortion of the usual elliptical shape of the spinal cord at the site of the shunt, a ''snake-eyes'' appearance of the cord on transverse images which corresponded to the position of the shunt within or next to a collapsed syringohydromelic cavity, and a generous amount of subachnoid space surrounding the collapsed portion of the cavity. Occasionally the shunt could not be visualized on sagittal images but could be seen on transverse images. In the majority of cases, the MR imaging findings were sufficiently characteristic to warrant accurate diagnosis

  1. Reactors

    DEFF Research Database (Denmark)

    Shah, Vivek; Vaz Salles, Marcos António

    2018-01-01

    The requirements for OLTP database systems are becoming ever more demanding. Domains such as finance and computer games increasingly mandate that developers be able to encode complex application logic and control transaction latencies in in-memory databases. At the same time, infrastructure...... engineers in these domains need to experiment with and deploy OLTP database architectures that ensure application scalability and maximize resource utilization in modern machines. In this paper, we propose a relational actor programming model for in-memory databases as a novel, holistic approach towards......-level function calls. In contrast to classic transactional models, however, reactors allow developers to take advantage of intra-transaction parallelism and state encapsulation in their applications to reduce latency and improve locality. Moreover, reactors enable a new degree of flexibility in database...

  2. The Texts of the Instruments Concerning the Agency's Assistance to Pakistan in connection with the Establishment of a Nuclear Power Reactor Project

    International Nuclear Information System (INIS)

    1968-01-01

    The terms of the Supply Agreement between the Agency and the Governments of Pakistan and the United States of America, and of the Project Agreement between the Agency and the Government of Pakistan concerning the Agency's assistance to that Government in connection with the establishment of a nuclear power reactor project, are reproduced herein for the information of all Members. Both Agreements entered into force on 17 June 1968

  3. The Texts of the Instruments concerning the Agency's Assistance to Pakistan in connection with the Establishment of a Nuclear Power Reactor Project. A Second Supply Agreement

    International Nuclear Information System (INIS)

    1971-01-01

    As a sequel to the assistance which the Agency provided to the Government of Pakistan in connection with a nuclear power reactor project, a Second Supply Agreement has been concluded between the Agency and the Governments of Pakistan and the United States of America. This Agreement entered into force on 22 June 1971, and the text is reproduced herein for the information of all Members

  4. The Texts of the Instruments Concerning the Agency's Assistance to Pakistan in connection with the Establishment of a Nuclear Power Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1968-09-06

    The terms of the Supply Agreement between the Agency and the Governments of Pakistan and the United States of America, and of the Project Agreement between the Agency and the Government of Pakistan concerning the Agency's assistance to that Government in connection with the establishment of a nuclear power reactor project, are reproduced herein for the information of all Members. Both Agreements entered into force on 17 June 1968.

  5. The Texts of the Instruments connected with the Agency's Assistance to Argentina in Establishing a Research and Isotope Production Reactor Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1965-11-04

    The texts of the Title Transfer Agreement between the Agency and the Governments of Argentina and the United States of America, and of the Project Agreement between the Agency and the Government of Argentina, in connection with the Agency's assistance to that Government in establishing a research and isotope production reactor project, are reproduced in this document for the information of all Members. These Agreements entered into force on 2 December 1964.

  6. The Texts of the Instruments connected with the Agency's Assistance to the Democratic Republic of the Congo in Continuing a Research Reactor Project. A Second Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1971-10-04

    As a sequel to the assistance which the Agency provided to the Government of the Democratic Republic of the Congo in connection with a research reactor project, a Second Supply Agreement has been concluded between the Agency and the Governments of the Congo and the United States of America. This Agreement entered into force on 15 April 1971, and the text is reproduced herein for the information of all Members.

  7. The Texts of the Instruments concerning the Agency's Assistance to Pakistan in connection with the Establishment of a Nuclear Power Reactor Project. A Second Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1971-10-08

    As a sequel to the assistance which the Agency provided to the Government of Pakistan in connection with a nuclear power reactor project, a Second Supply Agreement has been concluded between the Agency and the Governments of Pakistan and the United States of America. This Agreement entered into force on 22 June 1971, and the text is reproduced herein for the information of all Members.

  8. The Texts of the Instruments connected with the Agency's Assistance to the Democratic Republic of the Congo in Continuing a Research Reactor Project. A Second Supply Agreement

    International Nuclear Information System (INIS)

    1971-01-01

    As a sequel to the assistance which the Agency provided to the Government of the Democratic Republic of the Congo in connection with a research reactor project, a Second Supply Agreement has been concluded between the Agency and the Governments of the Congo and the United States of America. This Agreement entered into force on 15 April 1971, and the text is reproduced herein for the information of all Members

  9. The Texts of the Instruments connected with the Agency's Assistance to Mexico in Establishing a Research Reactor Project. A Second Supply Agreement

    International Nuclear Information System (INIS)

    1972-01-01

    As a sequel to the assistance which the Agency has provided to the Government of Mexico in connection with a research reactor project, a Second Supply Agreement has been concluded between the Agency and the Governments of Mexico and the United States of America. This Agreement entered into force on 4 October 1972, and the text is reproduced herein for the information of all Members

  10. The Texts of the Instruments connected with the Agency's Assistance to Mexico in Establishing a Research Reactor Project. A Second Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1972-11-17

    As a sequel to the assistance which the Agency has provided to the Government of Mexico in connection with a research reactor project, a Second Supply Agreement has been concluded between the Agency and the Governments of Mexico and the United States of America. This Agreement entered into force on 4 October 1972, and the text is reproduced herein for the information of all Members.

  11. The Texts of the Instruments connected with the Agency's Assistance to Argentina in Establishing a Research and Isotope Production Reactor Project

    International Nuclear Information System (INIS)

    1965-01-01

    The texts of the Title Transfer Agreement between the Agency and the Governments of Argentina and the United States of America, and of the Project Agreement between the Agency and the Government of Argentina, in connection with the Agency's assistance to that Government in establishing a research and isotope production reactor project, are reproduced in this document for the information of all Members. These Agreements entered into force on 2 December 1964

  12. The Texts of the Instruments connected with the Agency's Assistance to Pakistan in Establishing a Research Reactor Project. A Third Supply Agreement

    International Nuclear Information System (INIS)

    1974-01-01

    As a sequel to the assistance which the Agency has provided to the Government of Pakistan in connection with a research reactor project, a Third Supply Agreement has been concluded between the Agency and the Governments of Pakistan and the United States of America. The Agreement entered into force on 14 June 1974 pursuant to Article V, and the text is reproduced herein for the information of all Members

  13. Ventriculoperitoneal shunt complications needing shunt revision in children: A review of 5 years of experience with 48 revisions

    Directory of Open Access Journals (Sweden)

    Rajendra K Ghritlaharey

    2012-01-01

    Full Text Available Background: The aim of this study was to review the management of ventriculoperitoneal (VP shunt complications in children. Patients and Methods: During the last 5 years (January 1, 2006 to December 31, 2010, 236 VP shunt operations were performed in children under 12 years of age; of these, 40 (16.94% developed shunt complications and those who underwent VP shunt revisions were studied. Results: This prospective study included 40 (28 boys and 12 girls children and required 48 shunt revisions. Complications following VP shunts that required shunt revisions were peritoneal catheter/peritoneal end malfunction (18, shunt/shunt tract infections (7, extrusion of peritoneal catheter through anus (5, ventricular catheter malfunction (4, cerebrospinal fluid (CSF leak from abdominal wound (4, shunt system failure (2, ventricular end/shunt displacement (2, CSF pseudocysts peritoneal cavity (2, extrusion of peritoneal catheter from neck, chest, abdominal scar and through umbilicus, one each. Four-fifth of these shunt complications occurred within 6 months of previous surgery. Surgical procedures done during shunt revisions in order of frequency were revision of peritoneal part of shunt (27, 56.25%, revision of entire shunt system (6, 12.5%, extra ventricular drainage and delayed re-shunt (5, 10.41%, shunt removal and delayed re-shunt (5, 10.41%, opposite side shunting (2, 4.16%, cysts excision and revision of peritoneal catheter (2, 4.16% and revision of ventricular catheter (1, 2.08%. The mortalities following VP shunt operations were 44 (18.64% and following shunt revisions were 4 (10%. Conclusions: VP shunt done for hydrocephalus in children is not only prone for complications and need for revision surgery but also associated with considerable mortality.

  14. Research progress in TIPS shunt dysfunction and recanalization

    Directory of Open Access Journals (Sweden)

    WANG Tingting

    2015-11-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS is widely used in the treatment of cirrhotic portal hypertension and its associated complications. However, postoperative shunt dysfunction has been an important factor restricting the clinical application of TIPS. This article summarizes the use of shunt, the incidence of shunt dysfunction after TIPS, preventive measures and diagnostic methods for shunt dysfunction, and indications and techniques of shunt recanalization, in order to enhance our knowledge of shunt dysfunction and recanalization, which could further improve the efficacy of TIPS for cirrhotic portal hypertension.

  15. Reactor

    International Nuclear Information System (INIS)

    Fujibayashi, Toru.

    1976-01-01

    Object: To provide a boiling water reactor which can enhance a quake resisting strength and flatten power distribution. Structure: At least more than four fuel bundles, in which a plurality of fuel rods are arranged in lattice fashion which upper and lower portions are supported by tie-plates, are bundled and then covered by a square channel box. The control rod is movably arranged within a space formed by adjoining channel boxes. A spacer of trapezoidal section is disposed in the central portion on the side of the channel box over substantially full length in height direction, and a neutron instrumented tube is disposed in the central portion inside the channel box. Thus, where a horizontal load is exerted due to earthquake or the like, the spacers come into contact with each other to support the channel box and prevent it from abnormal vibrations. (Furukawa, Y.)

  16. The text of the Agreement of 25 September 1980 between Cuba and the Agency for the application of safeguards in connection with the supply of a nuclear research reactor from the Union of Soviet Socialist Republics

    International Nuclear Information System (INIS)

    1982-08-01

    The full text of the agreement between Cuba and the International Atomic Energy Agency for the application of safeguards in connection with the supply of a nuclear research reactor from the USSR is presented

  17. The text of the Agreement of 12 June 1981 between Viet Nam and the Agency relating to the application of safeguards in connection with the supply of nuclear fuel for the Da Lat research reactor

    International Nuclear Information System (INIS)

    1982-02-01

    The full text of the agreement between Viet Nam and the International Atomic Energy Agency relating to the application of safeguards in connection with the supply of nuclear fuel for the DA LAT Research Reactor is presented

  18. Primary ventriculoperitoneal shunting outcomes: a multicentre clinical audit for shunt infection and its risk factors.

    Science.gov (United States)

    Woo, P Ym; Wong, H T; Pu, J Ks; Wong, W K; Wong, L Yw; Lee, M Wy; Yam, K Y; Lui, W M; Poon, W S

    2016-10-01

    To determine the frequency of primary ventriculoperitoneal shunt infection among patients treated at neurosurgical centres of the Hospital Authority and to identify underlying risk factors. This multicentre historical cohort study included consecutive patients who underwent primary ventriculoperitoneal shunting at a Hospital Authority neurosurgery centre from 1 January 2009 to 31 December 2011. The primary endpoint was shunt infection, defined as: (1) the presence of cerebrospinal fluid or shunt hardware culture that yielded the pathogenic micro-organism with associated compatible symptoms and signs of central nervous system infection or shunt malfunction; or (2) surgical incision site infection requiring shunt reinsertion (even in the absence of positive culture); or (3) intraperitoneal pseudocyst formation (even in the absence of positive culture). Secondary endpoints were shunt malfunction, defined as unsatisfactory cerebrospinal fluid drainage that required shunt reinsertion, and 30-day mortality. A primary ventriculoperitoneal shunt was inserted in 538 patients during the study period. The mean age of patients was 48 years (range, 13-88 years) with a male-to-female ratio of 1:1. Aneurysmal subarachnoid haemorrhage was the most common aetiology (n=169, 31%) followed by intracranial tumour (n=164, 30%), central nervous system infection (n=42, 8%), and traumatic brain injury (n=27, 5%). The mean operating time was 75 (standard deviation, 29) minutes. Shunt reinsertion and infection rates were 16% (n=87) and 7% (n=36), respectively. The most common cause for shunt reinsertion was malfunction followed by shunt infection. Independent predictors for shunt infection were: traumatic brain injury (adjusted odds ratio=6.2; 95% confidence interval, 2.3-16.8), emergency shunting (2.3; 1.0-5.1), and prophylactic vancomycin as the sole antibiotic (3.4; 1.1-11.0). The 30-day all-cause mortality was 6% and none were directly procedure-related. This is the first Hong Kong

  19. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2012-02-01

    OBJECTIVES: Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts. METHODS: A retrospective chart review was conducted on 25 patients treated for IIH between 2001 and 2009. Age, sex, clinical presentation, methods of treatment and failure rates were recorded. RESULTS: Seventy-two per cent were treated initially with LP shunts. Failure rate was 11% in this group. Neuronavigation-assisted VP shunts were used to treat 28%. In this group, the failure rate was 14%. CONCLUSION: Our experience indicates that both LP shunts and VP shuts are effective in controlling all the clinical manifestations of IIH in the immediate postoperative period. Failure rates are slightly higher for VP shunts (14%) than LP shunts (11%). However, revision rates are higher with LP shunts (60%) than with VP shunts (30%).

  20. Resonant Electromagnetic Shunt Damping of Flexible Structures

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker

    2016-01-01

    Electromagnetic transducers convert mechanical energy to electrical energy and vice versa. Effective passive vibration damping of flexible structures can therefore be introduced by shunting with an accurately calibrated resonant electrical network thatcontains a capacitor to create the desired...

  1. Endoscopic third ventriculostomy versus ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Patients' medical records, operative notes, and neural tube database records were used to complete a structured questionnaire. The difference in ... likely after 6 months. Keywords: obstructive hydrocephalus; endoscopic third ventriculostomy; ventriculoperitoneal shunt; children; paediatric surgery; neurosurgery; Ethiopia ...

  2. Nonconventional mesocaval prosthetic shunt interposition in ...

    African Journals Online (AJOL)

    years demonstrates shunt patency and normal development ... However, the child's condition and growth ... The child has satisfactory weight and growth gain. (40kg .... infants and toddlers: replacement with decellularized branched pulmonary.

  3. Chatter reduction in boring process by using piezoelectric shunt damping with experimental verification

    Science.gov (United States)

    Yigit, Ufuk; Cigeroglu, Ender; Budak, Erhan

    2017-09-01

    Chatter is a self-excited type of vibration that develops during machining due to process-structure dynamic interactions resulting in modulated chip thickness. Chatter is an important problem as it results in poor surface quality, reduced productivity and tool life. The stability of a cutting process is strongly influenced by the frequency response function (FRF) at the cutting point. In this study, the effect of piezoelectric shunt damping on chatter vibrations in a boring process is studied. In piezoelectric shunt damping method, an electrical impedance is connected to a piezoelectric transducer which is bonded on cutting tool. Electrical impedance of the circuit consisting of piezoceramic transducer and passive shunt is tuned to the desired natural frequency of the cutting tool in order to maximize damping. The optimum damping is achieved in analytical and finite element models (FEM) by using a genetic algorithm focusing on the real part of the tool point FRF rather than the amplitude. Later, a practical boring bar is considered where the optimum circuit parameters are obtained by the FEM. Afterwards, the effect of the optimized piezoelectric shunt damping on the dynamic rigidity and absolute stability limit of the cutting process are investigated experimentally by modal analysis and cutting tests. It is both theoretically and experimentally shown that application of piezoelectric shunt damping results in a significant increase in the absolute stability limit in boring operations.

  4. Radionuclide cisternography in diagnostics of obstruction hydrocephalus in introduced ventricculoperitoneal shunt

    International Nuclear Information System (INIS)

    Cernochova, I.; Lipina, R.

    2004-01-01

    To confirm or exclude a diagnosis of internal obstruction hydrocephalus in an 8-year old girl with an introduced ventriculoperitoneal (V-P) shunt Establishing the V-P shunt is indisputably the route of choice in non-communicating hydrocephalus. The existence of a V-P shunt, however, is connected with numerous risks, especially of injuries, infection as well as increased intraabdominal pressure - e.g. in pregnancy. The development of endoscopy in neurosurgery allows the creation of communication via the bottom of the third ventricle with basal cisterns, and the subsequent cancellation of a V-P shunt. We describe the case of an 8-year old girl with congenital internal hydrocephalus with an assumed obliteration of the Sylvian aqueduct with an established V-P shunt. An MR scan described the membrane in the area of the Sylvian aqueduct, but the disproportion between the dilatation of the lateral ventricles, third ventricle and fourth ventricle led the physician to doubt as to the accuracy of the diagnosis of internal obstruction hydrocephalus. Therefore we performed a radionuclide cisternography (in a modified manner), which proved an existing communication between the third and fourth cerebral ventricle and which contradicted the clinical diagnosis of obstruction hydrocephalus. (author)

  5. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients

    International Nuclear Information System (INIS)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I.

    2003-01-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs

  6. Endoscopic Third Ventriculostomy in Previously Shunted Children

    Directory of Open Access Journals (Sweden)

    Eva Brichtova

    2013-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is a routine and safe procedure for therapy of obstructive hydrocephalus. The aim of our study is to evaluate ETV success rate in therapy of obstructive hydrocephalus in pediatric patients formerly treated by ventriculoperitoneal (V-P shunt implantation. From 2001 till 2011, ETV was performed in 42 patients with former V-P drainage implantation. In all patients, the obstruction in aqueduct or outflow parts of the fourth ventricle was proved by MRI. During the surgery, V-P shunt was clipped and ETV was performed. In case of favourable clinical state and MRI functional stoma, the V-P shunt has been removed 3 months after ETV. These patients with V-P shunt possible removing were evaluated as successful. In our group of 42 patients we were successful in 29 patients (69%. There were two serious complications (4.7%—one patient died 2.5 years and one patient died 1 year after surgery in consequence of delayed ETV failure. ETV is the method of choice in obstructive hydrocephalus even in patients with former V-P shunt implantation. In case of acute or scheduled V-P shunt surgical revision, MRI is feasible, and if ventricular system obstruction is diagnosed, the hydrocephalus may be solved endoscopically.

  7. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2011-02-01

    Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts.

  8. The text of the instruments connected with the Agency's assistance to Argentina in establishing a research and isotope production reactor project

    International Nuclear Information System (INIS)

    1995-01-01

    The Agreement between the Republic of Argentina, the Federative Republic of Brazil, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials and the International Atomic Energy Agency for the Application of Safeguards came into force on 4 March 1994. As a result of the coming into force of the aforesaid Agreement for Argentina, the application of safeguards under the Project Agreement of 2 December 1964 between Argentina and the IAEA in connection with the Agency's assistance to Argentina in establishing a research and isotope production reactor project has been suspended

  9. GABA Shunt in Durum Wheat

    Directory of Open Access Journals (Sweden)

    Petronia Carillo

    2018-02-01

    Full Text Available Plant responses to salinity are complex, especially when combined with other stresses, and involve many changes in gene expression and metabolic fluxes. Until now, plant stress studies have been mainly dealt only with a single stress approach. However, plants exposed to multiple stresses at the same time, a combinatorial approach reflecting real-world scenarios, show tailored responses completely different from the response to the individual stresses, due to the stress-related plasticity of plant genome and to specific metabolic modifications. In this view, recently it has been found that γ-aminobutyric acid (GABA but not glycine betaine (GB is accumulated in durum wheat plants under salinity only when it is combined with high nitrate and high light. In these conditions, plants show lower reactive oxygen species levels and higher photosynthetic efficiency than plants under salinity at low light. This is certainly relevant because the most of drought or salinity studies performed on cereal seedlings have been done in growth chambers under controlled culture conditions and artificial lighting set at low light. However, it is very difficult to interpret these data. To unravel the reason of GABA accumulation and its possible mode of action, in this review, all possible roles for GABA shunt under stress are considered, and an additional mechanism of action triggered by salinity and high light suggested.

  10. Portal hypertension: A critical appraisal of shunt procedures with emphasis on distal splenorenal shunt in children

    Directory of Open Access Journals (Sweden)

    Nitin Sharma

    2014-01-01

    Full Text Available Background: Extrahepatic portal venous obstruction (EHPVO is the most common cause of pediatric portal hypertension. We analyzed the investigative protocol and results of portosystemic shunts in this group of patients. Materials and Methods: A total of 40 consecutive children aged below 12 years operated with a diagnosis of extra-hepatic portal hypertension formed the study group. Historical data and clinical data were collected. All patients underwent upper gastrointestinal endoscopy, ultrasound Doppler and computed tomographic portogram pre-operatively and post-operatively. Results with respect to shunt patency, hypersplenism and efficacy of different radiological investigations were collected. Results: A total of 40 patients, 28 boys and 12 girls constituted the study group. Lienorenal shunt (LRS was performed in 14 patients; distal splenorenal shunt in 21 patients and side-to-side lienorenal shunt in 4 patients, inferior mesenteric renal shunt was performed in 1 patient. Follow-up ranged from 36 to 70 months. At a minimum follow-up of 3 years, 32 (80% patients were found to have patent shunts. Patent shunts could be visualized in 30/32 patients with computer tomographic portogram (CTP and 28/32 with ultrasound. Varices regressed completely in 26/32 patients and in the rest incomplete regression was seen. Spleen completely regressed in 19/25 patients. Hypersplenism resolved in all patients with patent shunts. Conclusions: Portosystemic shunting in children with EHPVO is a viable option. While long-term cure rates are comparable with sclerotherapy, repeated hospital visits are reduced with one time surgery. Pre-operative and post-operative assessment can be performed with complimentary use of ultrasound, CTP and endoscopy.

  11. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  12. Modeling the effect of shunt current on the charge transfer efficiency of an all-vanadium redox flow battery

    Science.gov (United States)

    Chen, Yong-Song; Ho, Sze-Yuan; Chou, Han-Wen; Wei, Hwa-Jou

    2018-06-01

    In an all-vanadium redox flow battery (VRFB), a shunt current is inevitable owing to the electrically conductive electrolyte that fills the flow channels and manifolds connecting cells. The shunt current decreases the performance of a VRFB stack as well as the energy conversion efficiency of a VRFB system. To understand the shunt-current loss in a VRFB stack with various designs and operating conditions, a mathematical model is developed to investigate the effects of the shunt current on battery performance. The model is calibrated with experimental data under the same operating conditions. The effects of the battery design, including the number of cells, state of charge (SOC), operating current, and equivalent resistance of the electrolytes in the flow channels and manifolds, on the shunt current are analyzed and discussed. The charge-transfer efficiency is calculated to investigate the effects of the battery design parameters on the shunt current. When the cell number is increased from 5 to 40, the charge transfer efficiency is decreased from 0.99 to a range between 0.76 and 0.88, depending on operating current density. The charge transfer efficiency can be maintained at higher than 0.9 by limiting the cell number to less than 20.

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... then placed in this tunnel to keep the pathway open. Patients who typically need a TIPS have ... and stomach. A TIPS procedure involves creating a pathway through the liver that connects the portal vein ( ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... placed to keep the connection open and allow it to bring blood draining from the bowel back ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the esophagus and stomach. A TIPS procedure involves creating a pathway through the liver that connects the ... diseases. This can result in significant challenges in creating the TIPS. top of page Additional Information and ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... be connected to monitors that track your heart rate, blood pressure and pulse during the procedure. A ... after the procedure? Devices to monitor your heart rate and blood pressure will be attached to your ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver. A small metal device called a stent is placed to keep the connection open and ... a small, tubular metal device commonly called a stent . During a TIPS procedure, interventional radiologists use image ...

  18. Balanced calibration of resonant shunt circuits for piezoelectric vibration control

    DEFF Research Database (Denmark)

    Høgsberg, Jan; Krenk, Steen

    2012-01-01

    Shunting of piezoelectric transducers and suitable electric circuits constitutes an effective passive approach to resonant vibration damping of structures. Most common design concepts for resonant resistor-inductor (RL) shunt circuits rely on either maximization of the attainable modal damping...

  19. Coupling slots without shunt impedance drop

    International Nuclear Information System (INIS)

    Balleyguier, P.

    1996-01-01

    It is well known that coupling slots between adjacent cells in a π-mode structure reduce shunt impedance per unit length with respect to single cell cavities. To design optimized coupling slots, one has to answer the following question: for a given coupling factor, what shape, dimension, position and number of slots lead to the lowest shunt impedance drop? A numerical study using the 3D code MAFIA has been carried out. The aim was to design the 352 MHz cavities for the high intensity proton accelerator of the TRISPAL project. The result is an unexpected set of four 'petal' slots. Such slots should lead to a quasi-negligible drop in shunt impedance: about -1% on average, for particle velocity from 0.4 c to 0.8 c. (author)

  20. Distal splenorenal shunt with partial spleen resection

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2007-01-01

    Full Text Available Introduction: Hypersplenism is a common complication of portal hypertension. Cytopenia in hypersplenism is predominantly caused by splenomegaly. Distal splenorenal shunt (Warren with partial spleen resection is an original surgical technique that regulates cytopenia by reduction of the enlarged spleen. Objective. The aim of our study was to present the advantages of distal splenorenal shunt (Warren with partial spleen resection comparing morbidity and mortality in a group of patients treated by distal splenorenal shunt with partial spleen resection with a group of patients treated only by a distal splenorenal shunt. Method. From 1995 to 2003, 41 patients with portal hypertension were surgically treated due to hypersplenism and oesophageal varices. The first group consisted of 20 patients (11 male, mean age 42.3 years who were treated by distal splenorenal shunt with partial spleen resection. The second group consisted of 21 patients (13 male, mean age 49.4 years that were treated by distal splenorenal shunt only. All patients underwent endoscopy and assessment of oesophageal varices. The size of the spleen was evaluated by ultrasound, CT or by scintigraphy. Angiography was performed in all patients. The platelet and white blood cell count and haemoglobin level were registered. Postoperatively, we noted blood transfusion, complications and total hospital stay. Follow-up period was 12 months, with first checkup after one month. Results In the first group, only one patient had splenomegaly postoperatively (5%, while in the second group there were 13 patients with splenomegaly (68%. Before surgery, the mean platelet count in the first group was 51.6±18.3x109/l, to 118.6±25.4x109/l postoperatively. The mean platelet count in the second group was 67.6±22.8x109/l, to 87.8±32.1x109/l postoperatively. Concerning postoperative splenomegaly, statistically significant difference was noted between the first and the second group (p<0.05. Comparing the

  1. Biophysical shunt theory for neuropsychopathology: Part I.

    Science.gov (United States)

    Naisberg, Y; Avnon, M; Weizman, A

    1995-11-01

    We present a new model of the origin of schizophrenia based on biophysical ionic shunts in neuronal (electrical) pathways. Microstructural and molecular evidence is presented for the way in which changes in the neuronal membrane ionic channels may facilitate membrane property rearrangement, leading to a change in the density and composition of the ion channel charge which in turn causes a change in ionic flow orientation and distribution. We suggest that, under abnormal conditions, ionic flow shunts are created which redirect the biophysical collateral neuronal (electrical) pathways, resulting in psychiatric signs and symptoms. This model is complementary to the biological basis of schizophrenia.

  2. Genetic and Functional Analysis of Congenital Portosystemic Shunts in Dogs

    NARCIS (Netherlands)

    van den Bossche, L.

    2017-01-01

    The general aim of this thesis was to gain further insight into the pathogenesis of congenital portosystemic shunts (CPSS), elucidate mechanisms involved in the pathophysiology of CPSS, and explore predictors of recovery after surgical ligation of the shunt. For intrahepatic portosystemic shunts

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... connected to monitors that track your heart rate, blood pressure and pulse during the procedure. A nurse or technologist will insert an intravenous (IV) line into a vein in your hand or arm so that sedative medication can be given intravenously. ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... is a tract created within the liver using x-ray guidance to connect two veins within the liver. ... containing iodine (sometimes referred to as "dye" or "x-ray dye"). Your physician may advise you to stop ...

  5. Connected analysis nuclear-thermo-hydraulic of parallel channels of a BWR reactor using distributed computation; Analisis acoplado nuclear-termohidraulico de canales paralelos de un reactor BWR empleando computacion distribuida

    Energy Technology Data Exchange (ETDEWEB)

    Campos Gonzalez, Rina Margarita

    2007-07-15

    This work consists of the integration of three models previously developed which are described widely in Literature: model of the thermo-hydraulic channel, model of the modal neutronic and the model of the recirculation bows. The tool used for this connection of models is the PVM system, Parallel Virtual Machine that allowed paralleling the model by means of the concept of distributed computation. The purpose of making this connection of models is the one of obtaining a more complete tool than better represents the real configuration and the phenomenology of the nucleus of a BWR reactor, thus obtaining better results. In addition to maintaining the flexibility to improve the resulting model at any time, since the very complex or sophisticated models are difficult to improve being impossible to modify the equations they use and can include variables that are not of primary importance in the tackled problem or that mask relations among variables due to the excess of results. Also maintaining the flexibility for adding component of models or systems of the BWR reactor, all of this following the modeling needs. The Swedish Ringhals power plant was chosen to characterize the resulting connected model for counting on a Stability Benchmark that offers the opportunity to count on real plant data. Besides that in case 9 of cycle 14 of this Benchamark oscillations outside phase appeared, which are from great interest because the detection systems that register the average of the power of the nucleus do not detect them. Additionally in this work the model of the recirculation bows as an independent module is obtained in an individual way, since this model belongs to another work and works connected to the reactor vessel. The model of the recirculation bows is able to model several transients of interest, as it is shown in the Appendix A of this work, among which are found the tripping of recirculation pumps or the transference at low or high velocity of them. The scope of the

  6. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  7. ARTIFICIAL SHUNTING OF CEREBROSPINAL-FLUID

    NARCIS (Netherlands)

    HOEKSTRA, A

    A compact three-stage shunt valve system (Orbis SigmaTM Valve) which operates as a flow regulator within certain differential pressure values has been clinically evaluated in the treatment of hydrocephalus. Clinical trials were performed in 134 cases, covering 128 patients aged from 1 day to 79

  8. Ventriculoperitoneal shunt infection caused by Bifidobacterium breve.

    Science.gov (United States)

    Suwantarat, Nuntra; Romagnoli, Mark; Wakefield, Teresa; Carroll, Karen C

    2014-08-01

    Bifidobacterium breve is a rare cause of human infections. Previously, bacteremia and meningitis caused by this organism linked to probiotic use have been reported in a neonate. We report the first case of a ventriculoperitoneal shunt infection caused by B. breve in an adult without a history of probiotic use. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Complications of ventriculoperitoneal shunt in hydrocephalic children

    African Journals Online (AJOL)

    These children were treated at the Department of Pediatric Surgery, Dr. Behc¸et Uz Children's Hospital, and at the Department of Neurosurgery, Tepecik Training Hospital. Management of these patients with special emphasis on the literature pertaining to the migration of shunt catheters into the scrotum is reviewed and ...

  10. A new electromagnetic shunt damping treatment and vibration control of beam structures

    International Nuclear Information System (INIS)

    Niu Hongpan; Zhang Xinong; Xie Shilin; Wang Pengpeng

    2009-01-01

    In this paper a new class of shunted electromagnetic damping treatment is proposed: a non-contact electromagnetic shunt damper (NC-EMSD). The NC-EMSD consists of an electromagnet attached to a host structure, a permanent magnet attached to the fixed boundary and an electrical impedance connected to the terminals of the electromagnet. The electromagnet and the shunt impedance constitute a closed circuit. When the structure vibrates, an induced electromotive force will be produced and results in the electromagnetic force as damping force, which can suppress the vibration of the structure. The model of NC-EMSD is built up based on the equivalent current method. The governing equations of the beam with NC-EMSD are established using Hamilton's principle. The capacitor-matching-inductance (CMI) method and the negative resistive capacitor-matching-inductance (NR-CMI) method are proposed, respectively. Then the vibration control of a cantilever beam with NC-EMSD is simulated and measured by CMI and NR-CMI control methods, respectively. The results show that both the CMI and NR-CMI can attenuate the vibration effectively, and the NR-CMI provides much better control performance than that by CMI. It is indicated as well from the studies that the decrease of either the gap between the magnet pair or the resistance of the shunt impedance contributes to the improvement of control performance

  11. Pictorial essay: trans-jugular intra-hepatic porto-systemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Rao Anuradha, T.N.; Rastogi, H.; Pandey, U.C.

    2001-01-01

    TIPS is an interventional radiologic method of creating a portosystemic shunt by percutaneous means. It is a relatively new weapon in the armamentarium of the management of portal hypertension with variceal bleeding or intractable ascites. Using needles, angioplasty balloon catheters and expandable metallic stents, a shunt is established directly inside the liver parenchyma connecting a large hepatic vein with a main portal vein branch. Depending on the diameter of the expandable stent used, the created TIPS diverts various amounts of portal blood into the systemic circulation and results in significant portal decompression, cessation of hemorrhage from esophageal varices and resolution of ascites. TIPS is not only an effective and safe alternative to shunt surgery but is life saving in cases of variceal hemorrhage. The use of TIPS seems to be a valid alternative to surgery and has several advantages over either esophageal transection or surgical shunts. TIPS avoids a general anesthetic, laparotomy, and disruption of the hepatic venous system that may adversely affect subsequent hepatic transplantation. TIPS has been performed on patients without interfering with successful transplantation

  12. The Texts of the Instruments connected with the Agency's Assistance to Yugoslavia in Establishing a Research Reactor Project. The Third Supply Agreement. Amendments

    International Nuclear Information System (INIS)

    1975-01-01

    On 29 December 1972 the Agency and the Governments of the United States of America and Yugoslavia amended by letter of agreement Sections l(i), 4 and 5 of the Third Supply Agreement, concluded in connection with the Agency's assistance to Yugoslavia for the continuation of a research reactor project and reproduced in document INFCIRC/32/Add. 3, to provide for the transfer to Yugoslavia of up to a total net amount of 4800 grams of uranium-23 5 contained in uranium enriched up to approximately 70 per cent in the isotope uranium-235, and for payment by Yugoslavia within 20 days from the date of the invoice received from the Agency and by the Agency within 30 days from the date of the invoice received from the United States Atomic Energy Commission

  13. Numerical analysis of performance of steam reformer of methane reforming hydrogen production system connected with high-temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Yin Huaqiang; Jiang Shengyao; Zhang Youjie

    2007-01-01

    Methane conversion rate and hydrogen output are important performance indexes of the steam reformer. The paper presents numerical analysis of performance of the reformer connected with high-temperature gas-cooled reactor HTR-10. Setting helium inlet flow rate fixed, performance of the reformer was examined with different helium inlet temperature, pressure, different process gas temperature, pressure, flow rate, and different steam to carbon ratio. As the range concerned, helium inlet temperature has remarkable influence on the performance, and helium inlet temperature, process gas temperature and pressure have little influence on the performance, and improving process gas flow rate, methane conversion rate decreases and hydrogen output increases, however improving steam to carbon ratio has reverse influence on the performance. (authors)

  14. A study concerning tritium concentration evolution in the moderator of a CANDU reactor connected on-line to a detritiation facility

    International Nuclear Information System (INIS)

    Bidica, Nicolae; Bornea, Anisia

    2005-01-01

    The present work is a theoretical study on the tritium concentration evolution in the CANDU reactor moderator connected on-line with a detritiation facility. This study is based on a calculation model which takes into account the evolution curve of the tritium concentration in the absence of detritiation process in both the moderator and SPTC of the Unit 1 CANDU reactor at Cernavoda NPP. This study leads to determination of the tritium concentration evolution in the moderator in the presence of the detritiation process for both a range of intake flows and initial concentration. Also, the intake flow change will be analyzed for a detritiation facility as a function of tritium initial concentration existing in the moderator in the case of a survey of the detritiation over a given period of time. The conclusions of this study were the following: - an optimum of the detritiation factor can be determined; - detritiation starts at a lower value for the tritium concentration in moderator which reduces the strain upon the detritiation facility and therefore the costs of its building, maintenance and operation. (authors)

  15. Comparison of Acute Thrombogenicity for Metallic and Polymeric Bioabsorbable Scaffolds: Magmaris Versus Absorb in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Waksman, Ron; Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David M; Westman, Peter C; Joner, Michael; Zumstein, Philine; Kolodgie, Frank D; Virmani, Renu

    2017-08-01

    A comparison in acute thrombogenicity between the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold and the Absorb bioresorbable vascular scaffold has not been performed. This study assessed acute thrombogenicity of Magmaris compared with Absorb and the Orsiro hybrid drug-eluting stent in a porcine arteriovenous shunt model. An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to SYLGARD tubing containing the Magmaris, Absorb, and Orsiro scaffolds/stents and allowed to run in the shunt for a maximum of 1 hour. Twelve shunts (2 shunt runs per pig) were run comparing the 3 scaffolds in alternating order. Nested generalized linear mixed models were used to compare variables between scaffold groups while adjusting for variability between shunt runs. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that both Magmaris (3.0%) and Orsiro (4.6%) had less platelet coverage of the total scaffold compared with Absorb (21.8%). Scanning electron microscopy demonstrated significantly less thrombus deposition to Magmaris as a percentage of the total scaffold compared with Absorb (5.0% versus 16.1%, P =0.02). Magmaris had significantly less PM-1-positive neutrophil and CD14-positive monocyte adherence compared with both Orsiro and Absorb. Orsiro had significantly less monocyte deposition compared with Absorb. Despite a similar scaffold strut thickness, the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold was significantly less thrombogenic compared with the Absorb bioresorbable vascular scaffold in an ex vivo porcine arteriovenous shunt model. Further studies are needed to determine whether the reduced thrombogenicity of Magmaris will result in reductions in major cardiovascular events. © 2017 American Heart Association, Inc.

  16. Pathological Predictors of Shunt Stenosis and Hepatic Encephalopathy after Transjugular Intrahepatic Portosystemic Shunt

    Directory of Open Access Journals (Sweden)

    Fuliang He

    2016-01-01

    Full Text Available Background. Transjugular intrahepatic portosystemic shunt (TIPS is an artificial channel from the portal vein to the hepatic vein or vena cava for controlling portal vein hypertension. The major drawbacks of TIPS are shunt stenosis and hepatic encephalopathy (HE; previous studies showed that post-TIPS shunt stenosis and HE might be correlated with the pathological features of the liver tissues. Therefore, we analyzed the pathological predictors for clinical outcome, to determine the risk factors for shunt stenosis and HE after TIPS. Methods. We recruited 361 patients who suffered from portal hypertension symptoms and were treated with TIPS from January 2009 to December 2012. Results. Multivariate logistic regression analysis showed that the risk of shunt stenosis was increased with more severe inflammation in the liver tissue (OR, 2.864; 95% CI: 1.466–5.592; P=0.002, HE comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, or higher MELD score (95% CI, 1.298–1.731; P<0.001. Higher risk of HE was associated with shunt stenosis comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, higher stage of the liver fibrosis (OR, 2.431; 95% CI, 1.355–4.359; P=0.003, and higher MELD score (95% CI, 1.711–2.406; P<0.001. Conclusion. The pathological features can predict individual susceptibility to shunt stenosis and HE.

  17. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients; Utilidad del Doppler color y pulsado en la valoracion de los shunts portosistemicos quirurgicos en la edad pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I. [Hospital Universitario La Paz. Madrid (Spain)

    2003-07-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs.

  18. Comparison of Acute Thrombogenicity for Magnesium versus Stainless Steel Stents in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David G; Joner, Michael; Harder, Claus; Zumstein, Philine; Finn, Aloke V; Kolodgie, Frank D; Virmani, Renu; Waksman, Ron

    2018-05-08

    Aims The aetiology for reduced thrombogenicity of the Magmaris resorbable magnesium scaffold (RMS) when compared with the Absorb bioresorbable vascular scaffold remains unclear. We therefore investigated whether the Magmaris RMS has platelet-repelling properties by comparing its acute thrombogenicity with an equivalent stainless steel stent in an arteriovenous shunt model. Methods and Results An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to Sylgard tubing containing the Magmaris RMS with sirolimus-eluting PLLA coating and an equivalent 316L stainless steel stent with sirolimus-eluting PLLA coating. Six shunts (2 shunt runs per pig) were run comparing the 2 scaffolds (n=9) in alternating order. Nested generalised linear mixed models were employed to compare variables between scaffold groups. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that the 316L equivalent stent had significantly greater platelet coverage of the total scaffold compared with Magmaris (5.8% vs. 2.8%, Rate ratio 2.21 [1.41, 3.47], p=0.012). Scanning electron microscopy demonstrated significantly greater thrombus deposition on the 316L equivalent stent as a percentage of the total scaffold compared with Magmaris (8.0% vs. 5.3%, p=0.009). Magmaris also had significantly less CD14 positive monocyte deposition and a trend toward less PM-1 positive neutrophil compared with the 316L equivalent stent. Conclusion Despite having identical scaffold characteristics regarding geometrical design, Magmaris had significantly less thrombogenicity and inflammatory cell deposition compared with the equivalent 316L stainless steel stent in a porcine arteriovenous shunt model. These data suggest resorbable magnesium scaffolds may have inherent properties that reduce adhesion of platelets and inflammatory cells.

  19. Effect of electromagnetic navigated ventriculoperitoneal shunt placement on failure rates.

    Science.gov (United States)

    Jung, Nayoung; Kim, Dongwon

    2013-03-01

    To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

  20. Ventriculosubgaleal shunts for posthemorrhagic hydrocephalus in premature infants.

    Science.gov (United States)

    Willis, Brian K; Kumar, Cherukuri Ravi; Wylen, Esther L; Nanda, Anil

    2005-01-01

    The early management of posthemorrhagic hydrocephalus in premature infants is challenging and controversial. These infants need a temporary cerebrospinal fluid (CSF) diversion procedure until they gain adequate weight, and the blood and protein levels in CSF are reasonably low before permanent shunt can be placed. Various options are available with their associated advantages and disadvantages. Ventriculosubgaleal shunts have been recommended as a more physiologic and less invasive means of achieving this goal. We have performed this procedure in 6 premature infants to evaluate their effectiveness and complications. Six consecutive premature infants with posthemorrhagic hydrocephalus underwent placement of ventriculosubgaleal shunts over a 1-year period of time. We reviewed their clinical and imaging progress to assess the ability of the shunt to control hydrocephalus and the complication rates. In all 6 patients, the ventriculosubgaleal shunt controlled the progression of hydrocephalus as assessed by clinical and imaging parameters. A permanent shunt was avoided in 1 patient (16.6%). However, 4 patients developed shunt infections, 1 involving the ventriculosubgaleal shunt itself, and 3 immediately after conversion to ventriculoperitoneal shunt. The total infection rate of the series was 66.6%. All infections were caused by staphylococcus species. There was only a 1% shunt infection rate in our institution for all nonventriculosubgaleal shunts during the same period of time. Placement of ventriculosubgaleal shunts for interim CSF diversion in neonates with posthemorrhagic hydrocephalus is effective as a temporary method of CSF diversion. However, our experience has shown that it is associated with a unacceptably high CSF infection rate. A potential cause for infection is CSF stasis just beneath the extremely thin skin of the premature infants, promoting colonization by skin flora. CSF sampling before conversion to a permanent shunt and replacement of the proximal

  1. The text of the Agreement of 7 October 1983 between Cuba and the Agency for the application of safeguards in connection with the supply of a zero-power nuclear reactor from the Hungarian People's Republic

    International Nuclear Information System (INIS)

    1984-01-01

    The full text of the agreement of 7 October 1983 between Cuba and the Agency for the application of safeguards in connection with the supply of a zero-power nuclear reactor from the Hungarian People's Republic and to the nuclear material to be used therein to be supplied by the Union of Soviet Socialist Republics is presented

  2. Hydrocephalus shunt technology: 20 years of experience from the Cambridge Shunt Evaluation Laboratory.

    Science.gov (United States)

    Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H

    2014-03-01

    The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.

  3. Nitrogen heat pipe for cryocooler thermal shunt

    International Nuclear Information System (INIS)

    Prenger F.C.; Hill, D.D.; Daney, D.E.

    1996-01-01

    A nitrogen heat pipe was designed, built and tested for the purpose of providing a thermal shunt between the two stages of a Gifford-McMahan (GM) cryocooler during cooldown. The nitrogen heat pipe has an operating temperature range between 63 and 123 K. While the heat pipe is in this temperature range during the system cooldown, it acts as a thermal shunt between the first and second stage of the cryocooler. The heat pipe increases the heat transfer to the first stage of the cryocooler, thereby reducing the cooldown time of the system. When the heat pipe temperature drops below the triple point, the nitrogen working fluid freezes, effectively stopping the heat pipe operation. A small heat leak between cryocooler stages remains because of axial conduction along the heat pipe wall. As long as the heat pipe remains below 63 K, the heat pipe remains inactive. Heat pipe performance limits were measured and the optimum fluid charge was determined

  4. Prophylactic antibiotics in pediatric shunt surgery.

    Science.gov (United States)

    Biyani, N; Grisaru-Soen, G; Steinbok, P; Sgouros, S; Constantini, S

    2006-11-01

    The optimal antibiotic prophylaxis for pediatric shunt-related procedures is not clear. There is much inconsistency among different medical centers. This paper summarizes and analyzes the various prophylactic antibiotic regiments used for shunt-related surgeries at different pediatric neurosurgery centers in the world. A survey questionnaire was distributed through the Pediatric Neurosurgery list-server (an e-mail-based special interest group in pediatric neurosurgery). Forty-five completed questionnaires were received, one per medical center, primarily from pediatric neurosurgeons with the following geographic breakdown: 25 from North America, 13 from Europe, and 7 from Asia and other countries. All centers routinely administered prophylactic antibiotics for shunt-related procedures. The drugs of choice were first-generation cephalosporins (23), second-generation cephalosporins (10), naficillin/oxacillin (4), vancomycin (3), clindamycin (1), amoxicillin (1), and mixed protocols in three centers. The initial drug administration ("first dose") was: in the department before transfer to operating room (5), upon arrival to operating room (11), at induction of anesthesia (13), and at initial skin incision (16). The duration of antibiotic dosage also varied: single dose (13), 24-h administration (26), 48-h administration (2), and longer than 48 h in four centers. Two general tendencies were noted, common to the majority of participating centers. There was a general trend to modify antibiotic treatment protocol in "high-risk" populations. The second common theme noted in more than half of responding centers was the use of long-term antibiotic treatment for externalized devices (such as externalized shunts, external ventricular drains or lumbar drains), usually till the device was in place.

  5. The transjugular intrahepatic portosystemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Owen, A.R.; Stanley, A.J.; Vijayananthan, A.; Moss, J.G.

    2009-01-01

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  6. Train shunting at a workshop area

    DEFF Research Database (Denmark)

    Jacobsen, Per Munk; Pisinger, David

    2011-01-01

    We consider the problem of planning the shunting of train units at a railway workshop area. Before and after the maintenance check, a train unit is parked at a depository track. The problem is to schedule the trains to workshops and depot tracks in order to complete the repairs as soon as possibl....... It turns out, that both GLS and SA find within a few minutes solutions that are a few percent from the best MIP solution found....

  7. The transjugular intrahepatic portosystemic shunt (TIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Owen, A.R. [Department of Radiology, Austin Health, Heidelberg, Melbourne (Australia)], E-mail: andrewowen@doctors.org.uk; Stanley, A.J. [Department of Gastroenterology, Glasgow Royal Infirmary, Glasgow (United Kingdom); Vijayananthan, A. [Department of Biomedical Imaging, University of Malaya, Kuala Lumpur (Malaysia); Moss, J.G. [Department of Radiology, Gartnavel General Hospital, Glasgow (United Kingdom)

    2009-07-15

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  8. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

    Science.gov (United States)

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  9. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography

    Directory of Open Access Journals (Sweden)

    Joshua M Owen

    2016-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US, and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS dysfunction. Materials and Methods: Forty-one patients (M:F 30:11, median age 55 years who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s, absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Results: Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77% patients were symptomatic, 33/52 (64% US examinations were abnormal, and 20/52 (38% TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52, while the agreement between US and shunt venography was 65% (34/52. Clinical symptoms and the US concurred in 60% (31/52 of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20 and 85% (17/20, respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32 for venographically abnormal shunts. Conclusion: Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  10. Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro.

    Science.gov (United States)

    Basati, Sukhraaj; Tangen, Kevin; Hsu, Ying; Lin, Hanna; Frim, David; Linninger, Andreas

    2015-12-01

    Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.

  11. Treatment of refractory chylothorax with externalized pleuroperitoneal shunts in children.

    Science.gov (United States)

    Wolff, A B; Silen, M L; Kokoska, E R; Rodgers, B M

    1999-09-01

    Traditional therapy for refractory chylothorax in the pediatric population has included pleurodesis and thoracic duct ligation. These procedures are associated with high morbidity and questionable success rates. We retrospectively reviewed our experience with 15 patients who underwent treatment for chylous effusions using pleuroperitoneal shunts with exteriorized pump chambers. Mean patient age at time of shunt placement was 2.1 (0.1 to 11.5) years and the most common indication (7 of 15) was refractory chylothorax following surgical correction of congenital heart disease. Mean chylothorax duration before shunt placement was 76 (5 to 810) days and shunts were in place for an average of 104 (12 to 365) days. A total of 19 chylous effusions (pleural or pericardial) were treated with shunts. Nine of 11 right-sided chylothoraces, 5 of 6 left-sided chylothoraces, and 2 of 2 chylopericardia resolved with shunt therapy (84% total). Pleuroperitoneal shunting failed to clear the effusion in 3 children. There were six episodes of shunt malfunction that were repaired and two episodes of infection. Inguinal or umbilical hernia developed in 4 patients. Externalized pleuroperitoneal shunting is a safe, effective, and minimally invasive treatment for children with refractory chylous effusions.

  12. Superconducting fault current-limiter with variable shunt impedance

    Science.gov (United States)

    Llambes, Juan Carlos H; Xiong, Xuming

    2013-11-19

    A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.

  13. FBR type reactor

    International Nuclear Information System (INIS)

    Kimura, Kimitaka; Fukuie, Ken; Iijima, Tooru; Shimpo, Masakazu.

    1994-01-01

    In an FBR type reactor for exchanging fuels by pulling up reactor core upper mechanisms, a connection mechanism is disposed for connecting the top of the reactor core and the lower end of the reactor core upper mechanisms. In addition, a cylindrical body is disposed surrounding the reactor core upper mechanisms, and a support member is disposed to the cylindrical body for supporting an intermediate portion of the reactor core upper mechanisms. Then, the lower end of the reactor core upper mechanisms is connected to the top of the reactor core. Same displacements are caused to both of them upon occurrence of earthquakes and, as a result, it is possible to eliminate mutual horizontal displacement between a control rod guide hole of the reactor core upper mechanisms and a control rod insertion hole of the reactor core. In addition, since the intermediate portion of the reactor core upper mechanisms is supported by the support member disposed to the cylindrical body surrounding the reactor core upper mechanisms, deformation caused to the lower end of the reactor core upper mechanisms is reduced, so that the mutual horizontal displacement with respect to the control rod insertion hole of the reactor core can be reduced. As a result, performance of control rod insertion upon occurrence of the earthquakes is improved, so that reactor shutdown is conducted more reliably to improve reactor safety. (N.H.)

  14. Over-drainage and persistent shunt-dependency in patients with idiopathic intracranial hypertension treated with shunts and bariatric surgery.

    Science.gov (United States)

    Roth, Jonathan; Constantini, Shlomi; Kesler, Anat

    2015-01-01

    Idiopathic intracranial hypertension (IIH) may lead to visual impairment. Shunt surgery is indicated for refractory IIH-related symptoms that persist despite medical treatment, or those presenting with significant visual decline. Obesity is a risk factor for IIH; a reduction in weight has been shown to improve papilledema. Bariatric surgery (BS) has been suggested for treating IIH associated with morbid obesity. In this study, we describe a high rate of over-drainage (OD) seen in patients following shunts and BS. The study cohort includes 13 patients with IIH that underwent shunt surgery for treatment of the IIH-related symptoms. Six patients underwent BS in addition to the shunt surgery (but not concomitantly). Seven patients had only shunt surgeries with no BS. Data were collected retrospectively. BS effectively led to weight reduction (body mass index decreasing from 43 ± 4 to 28 ± 5). Patients undergoing BS had 1-6 (2.5 ± 1.9) shunt revisions for OD following BS, as opposed to 0-3 (1.4 ± 1.1) revisions prior to BS over similar time spans (statistically insignificant difference), and 0-6 (1.6 ± 2.5) revisions among the non-BS patients over a longer time span (statistically insignificant difference). Two patients in the BS group underwent shunt externalization and closure; however, they proved to be shunt-dependent. Patients with IIH that undergo shunt surgery and BS (not concomitantly) may suffer from OD symptoms, necessitating multiple shunt revisions, and valve upgrades. Despite BS being a valid primary treatment for some patients with IIH, among shunted patients, BS may not lead to resolution of IIH-related symptoms and patients may remain shunt-dependent.

  15. Rate of shunt revision as a function of age in patients with shunted hydrocephalus due to myelomeningocele.

    Science.gov (United States)

    Dupepe, Esther B; Hopson, Betsy; Johnston, James M; Rozzelle, Curtis J; Jerry Oakes, W; Blount, Jeffrey P; Rocque, Brandon G

    2016-11-01

    OBJECTIVE It is generally accepted that cerebrospinal fluid shunts fail most frequently in the first years of life. The purpose of this study was to describe the risk of shunt failure for a given patient age in a well-defined cohort with shunted hydrocephalus due to myelomeningocele (MMC). METHODS The authors analyzed data from their institutional spina bifida research database including all patients with MMC and shunted hydrocephalus. For the entire population, the number of shunt revisions in each year of life was determined. Then the number of patients at risk for shunt revision during each year of life was calculated, thus enabling them to calculate the rate of shunt revision per patient in each year of life. In this way, the timing of all shunt revision operations for the entire clinic population and the likelihood of having a shunt revision during each year of life were calculated. RESULTS A total of 655 patients were enrolled in the spina bifida research database, 519 of whom had a diagnosis of MMC and whose mean age was 17.48 ± 11.7 years (median 16 years, range 0-63 years). Four hundred seventeen patients had had a CSF shunt for the treatment of hydrocephalus and thus are included in this analysis. There were 94 shunt revisions in the 1st year of life, which represents a rate of 0.23 revisions per patient in that year. The rate of shunt revision per patient-year initially decreased as age increased, except for an increase in revision frequency in the early teen years. Shunt revisions continued to occur as late as 43 years of age. CONCLUSIONS These data substantiate the idea that shunt revision surgeries in patients with MMC are most common in the 1st year of life and decrease thereafter, except for an increase in the early teen years. A persistent risk of shunt failure was observed well into adult life. These findings underscore the importance of routine follow-up of all MMC patients with shunted hydrocephalus and will aid in counseling patients and

  16. Surgical approach for systemic-pulmonary shunt in neonates with functionally univentricular heart: comparison between sternotomy and thoracotomy.

    Science.gov (United States)

    Sasaki, Takashi; Takeda, Yuko; Ohnakatomi, Yasuko; Asou, Toshihide

    2016-09-01

    The preferred surgical approach for systemic-pulmonary shunts has changed from thoracotomy to sternotomy in our institution, to concomitantly manage the ductus arteriosus during surgery. The purpose of this study was to compare the outcomes of systemic-pulmonary shunts for neonates with functionally univentricular hearts based on surgical approach. Fifty-two neonates with functionally univentricular hearts underwent systemic-pulmonary shunt via sternotomy (n = 28) or thoracotomy (n = 24). Patient characteristics, achievement rates of right heart bypass, and survival rates were compared for the different approaches. Prenatal diagnosis was made more common in the sternotomy group (p = 0.006). The shunt was placed more centrally in the sternotomy group. The ductus arteriosus was ligated or banded in most patients in the sternotomy group (26/28) and in a few patients in the thoracotomy group (6/24). Frequency of ductal management in the early postoperative phase was not different between the groups (21 vs 25 %), but three new incisions had to be made in the thoracotomy group. No differences were seen in the achievement rates of bidirectional cavopulmonary shunts (86 vs 87 % at 10 months of age) and total cavopulmonary connection (81 vs 81 % at 2 years of age), or in the survival rates (92 vs 96 % at 8 years). There were no differences in short- and long-term outcomes between the groups. The sternotomy approach might be preferable in the current era of prenatal diagnosis, to allow simultaneous duct management during systemic-pulmonary shunt surgery, particularly in patients with large ducts associated with functionally univentricular hearts.

  17. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-01-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts. (author)

  19. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-10-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts.

  20. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2011-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  1. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2012-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  2. Clopidogrel in infants with systemic-to-pulmonary-artery shunts

    DEFF Research Database (Denmark)

    Wessel, David L; Berger, Felix; Li, Jennifer S

    2013-01-01

    BACKGROUND: Infants with cyanotic congenital heart disease palliated with placement of a systemic-to-pulmonary-artery shunt are at risk for shunt thrombosis and death. We investigated whether the addition of clopidogrel to conventional therapy reduces mortality from any cause and morbidity relate......-related morbidity. (Funded by Sanofi-Aventis and Bristol-Myers Squibb; ClinicalTrials.gov number, NCT00396877.)....

  3. Migration of the peritoneal catheter of a ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Ventricular shunt is a well-established modality in the management of hydrocephalus. However, it can be associated with numerous complications and disastrous consequences. The reported incidence of intra-abdominal complications in infants and children after ventriculoperitoneal (VP) shunt procedures is about 24% ...

  4. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels shunt Hybrid Active ...

  5. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Zhang, Jun; Ouyang, Ziwei; Duffy, Maeve C.

    2014-01-01

    with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  6. An unusual case of intrahepatic portosystemic venous shunt

    African Journals Online (AJOL)

    vena cava (IVC) (most common). Intrahepatic portosystemic venous shunts are rare vascular anomalies that may be detected in asymptomatic patients, given the recent advances in radiological imaging techniques. Accurate shunt evaluation and classification can be performed with ultrasound and multi-detector computed.

  7. Automatic Railway Traffic Object Detection System Using Feature Fusion Refine Neural Network under Shunting Mode

    Directory of Open Access Journals (Sweden)

    Tao Ye

    2018-06-01

    Full Text Available Many accidents happen under shunting mode when the speed of a train is below 45 km/h. In this mode, train attendants observe the railway condition ahead using the traditional manual method and tell the observation results to the driver in order to avoid danger. To address this problem, an automatic object detection system based on convolutional neural network (CNN is proposed to detect objects ahead in shunting mode, which is called Feature Fusion Refine neural network (FR-Net. It consists of three connected modules, i.e., the depthwise-pointwise convolution, the coarse detection module, and the object detection module. Depth-wise-pointwise convolutions are used to improve the detection in real time. The coarse detection module coarsely refine the locations and sizes of prior anchors to provide better initialization for the subsequent module and also reduces search space for the classification, whereas the object detection module aims to regress accurate object locations and predict the class labels for the prior anchors. The experimental results on the railway traffic dataset show that FR-Net achieves 0.8953 mAP with 72.3 FPS performance on a machine with a GeForce GTX1080Ti with the input size of 320 × 320 pixels. The results imply that FR-Net takes a good tradeoff both on effectiveness and real time performance. The proposed method can meet the needs of practical application in shunting mode.

  8. An Enhanced Plane Wave Expansion Method to Solve Piezoelectric Phononic Crystal with Resonant Shunting Circuits

    Directory of Open Access Journals (Sweden)

    Ziyang Lian

    2016-01-01

    Full Text Available An enhanced plane wave expansion (PWE method is proposed to solve piezoelectric phononic crystal (PPC connected with resonant shunting circuits (PPC-C, which is named as PWE-PPC-C. The resonant shunting circuits can not only bring about the locally resonant (LR band gap for the PPC-C but also conveniently tune frequency and bandwidth of band gaps through adjusting circuit parameters. However, thus far, more than one-dimensional PPC-C has been studied just by Finite Element method. Compared with other methods, the PWE has great advantages in solving more than one-dimensional PC as well as various lattice types. Nevertheless, the conventional PWE cannot accurately solve coupling between the structure and resonant shunting circuits of the PPC-C since only taking one-way coupling from displacements to electrical parameters into consideration. A two-dimensional PPC-C model of orthorhombic lattice is established to demonstrate the whole solving process of PWE-PPC-C. The PWE-PPC-C method is validated by Transfer Matrix method as well as Finite Element method. The dependence of band gaps on circuit parameters has been investigated in detail by PWE-PPC-C. Its advantage in solving various lattice types is further illustrated by calculating the PPC-C of triangular and hexagonal lattices, respectively.

  9. Calibration of piezoelectric RL shunts with explicit residual mode correction

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Krenk, Steen

    2017-01-01

    Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained by an exte......Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained...... by an extension of the local piezoelectric transducer displacement by two additional terms, representing the flexibility and inertia contributions from the residual vibration modes not directly addressed by the shunt damping. This results in an augmented dynamic model for the targeted resonant vibration mode...

  10. Shunt attachment and method for interfacing current collection systems

    Science.gov (United States)

    Denney, Paul E.; Iyer, Natraj C.; Hannan, III, William F.

    1992-01-01

    A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature.

  11. Vibration damping with negative capacitance shunts: theory and experiment

    International Nuclear Information System (INIS)

    De Marneffe, B; Preumont, A

    2008-01-01

    This paper analyzes in detail the enhancement of piezoelectric stack transducers by means of the well known 'negative' capacitive shunting. The stability is thoroughly studied: starting from the electrical admittance curve of the transducer, a method is introduced that quantifies the stability margins of the shunted structure. Two different implementations (series vs parallel) are investigated, and the lack of robustness of the parallel one is demonstrated. Next, this technique is experimentally applied on a truss structure. Its performances are compared with those of passive shunt circuits and with those of an active control law, the so-called Integral Force Feedback or IFF. As expected, the damping introduced by the negative capacitance shunt is larger than the damping obtained with the passive shunts; it remains, however, one order of magnitude smaller than that obtained with the IFF

  12. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    International Nuclear Information System (INIS)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene; Monti, Cinzia; Bellomi, Massimo

    2002-01-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  13. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene [Division of Radiology, European Institute of Oncology, Milan (Italy); Monti, Cinzia [Institute of Radiology, University of Milan (Italy); Bellomi, Massimo [Division of Radiology, European Institute of Oncology, Milan (Italy); Institute of Radiology, University of Milan (Italy)

    2002-05-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  14. Parylene MEMS patency sensor for assessment of hydrocephalus shunt obstruction.

    Science.gov (United States)

    Kim, Brian J; Jin, Willa; Baldwin, Alexander; Yu, Lawrence; Christian, Eisha; Krieger, Mark D; McComb, J Gordon; Meng, Ellis

    2016-10-01

    Neurosurgical ventricular shunts inserted to treat hydrocephalus experience a cumulative failure rate of 80 % over 12 years; obstruction is responsible for most failures with a majority occurring at the proximal catheter. Current diagnosis of shunt malfunction is imprecise and involves neuroimaging studies and shunt tapping, an invasive measurement of intracranial pressure and shunt patency. These patients often present emergently and a delay in care has dire consequences. A microelectromechanical systems (MEMS) patency sensor was developed to enable direct and quantitative tracking of shunt patency in order to detect proximal shunt occlusion prior to the development of clinical symptoms thereby avoiding delays in treatment. The sensor was fabricated on a flexible polymer substrate to eventually allow integration into a shunt. In this study, the sensor was packaged for use with external ventricular drainage systems for clinical validation. Insights into the transduction mechanism of the sensor were obtained. The impact of electrode size, clinically relevant temperatures and flows, and hydrogen peroxide (H2O2) plasma sterilization on sensor function were evaluated. Sensor performance in the presence of static and dynamic obstruction was demonstrated using 3 different models of obstruction. Electrode size was found to have a minimal effect on sensor performance and increased temperature and flow resulted in a slight decrease in the baseline impedance due to an increase in ionic mobility. However, sensor response did not vary within clinically relevant temperature and flow ranges. H2O2 plasma sterilization also had no effect on sensor performance. This low power and simple format sensor was developed with the intention of future integration into shunts for wireless monitoring of shunt state and more importantly, a more accurate and timely diagnosis of shunt failure.

  15. Tube shunt complications and their prevention.

    Science.gov (United States)

    Sarkisian, Steven R

    2009-03-01

    Glaucoma drainage devices (GDDs) have been generally accepted as a treatment of refractory glaucoma. GDDs have their own unique set of complications that are important to evaluate to prevent them. Tube shunts are typically used in eyes with refractory glaucoma. There is increased interest in studying the efficacy of GDDs. Most of the attention has been focused on comparing trabeculectomy with the Baerveldt implant (Advanced Medical Optics, Inc., Santa Anna, California, USA). The other leading implant is the Ahmed Glaucoma Valve. There are several retrospective studies comparing these two devices and a prospective study is ongoing. There is great interest in the complication rate of tube shunts and these have been published both retrospectively and prospectively. Complications such as hypotony, diplopia, strabismus, proptosis, tube erosion, failure, corneal decompensation, endophthalmitis, and visual loss are all important and some have recently been reviewed in the literature. Moreover, the use of glaucoma drainage implants in the pediatric population has been evaluated. Glaucoma drainage implants have been a powerful tool in our surgical fight to prevent blindness; however, they are not without complications or controversy.

  16. Reactor container

    International Nuclear Information System (INIS)

    Kato, Masami; Nishio, Masahide.

    1987-01-01

    Purpose: To prevent the rupture of the dry well even when the melted reactor core drops into a reactor pedestal cavity. Constitution: In a reactor container in which a dry well disposed above the reactor pedestal cavity for containing the reactor pressure vessel and a torus type suppression chamber for containing pressure suppression water are connected with each other, the pedestal cavity and the suppression chamber are disposed such that the flow level of the pedestal cavity is lower than the level of the pressure suppression water. Further, a pressure suppression water introduction pipeway for introducing the pressure suppression water into the reactor pedestal cavity is disposed by way of an ON-OFF valve. In case if the melted reactor core should fall into the pedestal cavity, the ON-OFF valve for the pressure suppression water introduction pipeway is opened to introduce the pressure suppression water in the suppression chamber into the pedestal cavity to cool the melted reactor core. (Ikeda, J.)

  17. Hepatic Veins and Inferior Vena Cava Thrombosis in a Child Treated by Transjugular Intrahepatic Portosystemic Shunt

    International Nuclear Information System (INIS)

    Carnevale, Francisco Cesar; Santos, Aline Cristine Barbosa; Tannuri, Uenis; Cerri, Giovanni Guido

    2010-01-01

    We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge of the stent.

  18. Unsuccessful lung scan due to major right-to-left shunt through a sinus venosus septal defect

    International Nuclear Information System (INIS)

    Brendel, A.J.; Larnaudie, B.; Lambert, B.; Leccia, F.; Barat, J.L.; Ducassou, D.; Fontan, F.

    1985-01-01

    In a patient with a prior history of cerebral abscess and cerebral ischemia, an unsuccessful perfusion lung scan led to a radionuclide angiocardiogram using an arm vein injection. This showed a total right-to-left (R-L) shunt from the superior vena cava (SVC) to the left atrium. Repeat radionuclide study, through a leg vein, demonstrated a moderate R-L shunt and an interpretable lung scan could be obtained. Catheterization and contrast cineangiogram did not provide the exact diagnosis, the preoperative conclusion being anomalous drainage of the SVC into the left atrium, with atrial septal defect (ASD) and partial anomalous pulmonary venous connection to the SVC. The operative diagnosis was high atrial (sinus venosus) septal defect. This example of major but clinically unsuspected R-L shunt emphasizes the value of performing a perfusion lung scan, preferably in conjunction with radionuclide angiocardiography in patients with a prior history of unexplained cerebral abscess or systemic ischemia. Implications of the site of an ASD on quantitation of L-R shunts by radionuclide methods are also discussed

  19. Ventriculoperitoneal shunt infection in Haji Adam Malik Hospital, Medan

    Science.gov (United States)

    Dharmajaya, R.

    2018-03-01

    Installation of ventriculoperitoneal shunts (VP) represented a substantial progress in the neurosurgical management of hydrocephalus in children. However, infection is the most commonpostoperative complication of aventriculoperitoneal shunt. It is important because it is related to substantial morbidity and mortality, and exerts a negative impact on the quality of life of patients. We retrospectively analyzed all 20 cases of shunt infection from 2013 to 2016. The types of infections found were exposed shunts15 cases (75%), and 5 cases of ventriculitis (25%). Length of infection time which calculated from the beginning of surgery was 350.20 days or 11 months. The most common pathogen types are S. epidermidis followed by P. aeruginosa, E. coli, and A. baumanii. There were many risk factors for shunt infection, but the interesting fact was the level of pre-operative albumin. There was a significant difference between low albumin levels (<3.0) and normal albumin (≥3.0) levels against the risk of exposure shunt, p = 0.015. It means there is asignificant difference between low pre-operative albumin and normal level for the risk of theexposed shunt.

  20. A plasma polymerization technique to overcome cerebrospinal fluid shunt infections

    Energy Technology Data Exchange (ETDEWEB)

    Coekeliler, D [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey); Caner, H [Department of Neurosurgery, School of Medicine, Baskent University, 06610, Ankara (Turkey); Zemek, J [Institute of Physics, Academy of Sciences of the Czech Republic, Cukrovarnicka 10, 162 53, Prague, Czech Republic (Czech Republic); Choukourov, A [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Biederman, H [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Mutlu, M [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey)

    2007-03-01

    Prosthetic devices, mainly shunts, are frequently used for temporary or permanent drainage of cerebrospinal fluid. The pathogenesis of shunt infection is a very important problem in modern medicine and generally this is characterized by staphylococcal adhesion to the cerebrospinal fluid shunt surfaces. In this paper, the prevention of the attachment of test microorganism Staphylococcus epidermidis on the cerebrospinal fluid shunt surfaces by 2-hydroxyethylmethacrylate (HEMA) precursor modification in the plasma polymerization system, is reported. Different plasma polymerization conditions (RF discharge power 10-20-30 W, exposure time 5-10-15 min) were employed during the surface modification. The surface chemistry and topology of unmodified and modified shunts was characterized by x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Also, static contact angle measurements were performed to state the change of surface hydrophilicity. All samples were tested in vitro with Staphylococcus epidermidis. A plasma-polymerized HEMA film (PP HEMA) was found to be an alternative simple method to decrease the microorganism attachment and create bacterial anti-fouling surfaces. The attachment of the model microorganism Staphylococcus epidermidis on the shunt surface modified by PP HEMA at 20 W and 15 min was reduced 62.3% if compared to the unmodified control surface of the shunt.

  1. Research on spark discharge of floating roof tank shunt

    International Nuclear Information System (INIS)

    Bi, Xiaolei; Liu, Quanzhen; Liu, Baoquan; Gao, Xin; Hu, Haiyan; Liu, Juan

    2013-01-01

    In order to quantitatively analyze the spark discharge risk of floating roof tank shunts, the breakdown voltage of shunt has been calculated by Townsend theory, the shunt spark discharge experiment is carried out by using 1.2/50 μs impulse voltage wave, and the relationship between breakdown voltage of shunt spark discharge and air gap is analyzed. It has been indicated by theoretical analysis and experimental study that the small gap is more easily cause spark discharge than the big gap when the contact between shunt and tank shell is poor. When air gap distance is equal to 0.1 cm, average breakdown voltage is 5280 V. When the air gap distance is less than 0.3 cm, experiment data agree well with Townsend theory. Therefore, in the condition of small gap, Townsend theory can be used to calculated breakdown voltage of shunt. Finally, based on the above conclusions, improvements for avoiding the spark discharge risk of shunt of floating roof tanks have been proposed.

  2. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Directory of Open Access Journals (Sweden)

    Lindsay Van den Bossche

    Full Text Available Non-alcoholic fatty liver disease (NAFLD is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS and intrahepatic portosystemic shunts (IHPSS was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS P<0.01; IHPSS P = 0.042. Involvement of lipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  3. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Science.gov (United States)

    Van den Bossche, Lindsay; Schoonenberg, Vivien A C; Burgener, Iwan A; Penning, Louis C; Schrall, Ingrid M; Kruitwagen, Hedwig S; van Wolferen, Monique E; Grinwis, Guy C M; Kummeling, Anne; Rothuizen, Jan; van Velzen, Jeroen F; Stathonikos, Nikolas; Molenaar, Martijn R; Helms, Bernd J; Brouwers, Jos F H M; Spee, Bart; van Steenbeek, Frank G

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS) and intrahepatic portosystemic shunts (IHPSS) was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS Plipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  4. Portosystemic shunts for extrahepatic portal hypertension in children.

    Science.gov (United States)

    Tocornal, J; Cruz, F

    1981-07-01

    Twenty-three children with prehepatic portal hypertension and hemorrhage due to ruptured esophagogastric varices had portosystemic shunts. Their ages ranged from two years and seven months to 15 years. Eleven were less than eight years of age. Twenty patients had portal vein cavernomatosis and three patients had double portal veins. In 21 patients, a mesocaval type of shunt was done. A splenorenal shunt was performed in two. There was no surgical mortality. Two shunts occluded, both in rather young infants--two years and seven months and three years of age. In all the others, there was no further bleeding, and the shunts remained patent, as shown by abdominal angiograms. Neuropsychiatric disorders, probably due to hepatic encephalopathy, occurred in only one patient. On the basis of this favorable experience, we believe that an elective portosystemic shunt should, in general, be performed upon children with prehepatic portal hypertension after one major variceal hemorrhage. We favor a mesocaval type of shunt in these children because of the larger diameter of the vessels involved in the anastomosis and because it preserves the spleen, maintaining defense against subsequent infection.

  5. Prevention and treatment of complications after transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    XUE Hui

    2016-02-01

    Full Text Available The application of transjugular intrahepatic portosystemic shunt (TIPS in the treatment of cirrhotic portal hypertension has been widely accepted both at home and abroad. This article focuses on the fatal complications of TIPS (including intraperitoneal bleeding and acute pulmonary embolism, shunt failure, and recurrent portosystemic hepatic encephalopathy, and elaborates on the reasons for such conditions and related preventive measures, in order to improve the accuracy and safety of intraoperative puncture, reduce common complications such as shunt failure and hepatic encephalopathy, and improve the clinical effect of TIPS in the treatment of cirrhotic portal hypertension.

  6. Spinal cord arteriovenous shunts: from imaging to management

    International Nuclear Information System (INIS)

    Rodesch, G.; Lasjaunias, P.

    2003-01-01

    Spinal cord arteriovenous shunts (SCAVSs) are either fistulas or niduses that can be separated in four different groups according to their localization and relationship to the dura. Paraspinal AVSs are located outside the spine and are responsible for neurological symptoms because of cord compression by ertatic veins, venous congestion or arterial steal. Epidural shunts are located in the epidural space and drain in epidural veins with secondary intradural congestion. Dural shunts are embedded in the dura, produce a cord venous myelopathy after draining through veins that either pierce the dura far from a nerve root or accompany a nerve root. Intradural shunts affect the cord, the roots or the filum. Additionally, they can be classified according to their potential relationships with genetics, vascular biological features and angiogenesis into genetic hereditary lesions (hereditary hemorrhagic telangiectasia), genetic non-hereditary lesions (multiple lesions with metameric links) and single lesions (AVMs or micro AVFs). MRI and MRA are able to visualise SCAVS early after the onset of clinical symptoms. The type of shunt and its localization may remain difficult to be precise. Angiography remains the gold standard for analysis of the anatomical, morphological and architectural features necessary for therapeutic decisions in both paediatric and adult populations. In our series, embolisation is chosen in first intention whatever the type of shunt responsible for the clinical symptoms and glue is preferably used. In paraspinal, dural or epidural arteriovenous shunts, the goal of treatment should be complete closure of the shunt. A complete cure by embolization is rather easily achieved in paraspinal lesions. Failure of endovascular therapy in dural or epidural shunts must bring the patient to surgery. The prognosis of most intradural shunts seems better than previously thought, even after haemorrhage. In intradural spinal cord arteriovenous shunts, embolisation

  7. Nuclear reactor shutdown system

    International Nuclear Information System (INIS)

    Mangus, J.D.; Cooper, M.H.

    1982-01-01

    An improved nuclear reactor shutdown system is described comprising a temperature sensitive device connected to control the electric power supply to a magnetic latch holding a body of a neutron absorbing material. The temperature sensitive device is exposed to the reactor coolant so that when the reactor coolant temperature rises above a specific level, the temperature sensitive device will cause deenergization of the magnetic latch to allow the body of neutron absorbing material to enter the reactor core. (author)

  8. Scoliosis and Syringomyelia With Chiari Malformation After Lumbar Shunting

    Directory of Open Access Journals (Sweden)

    Hsin-Hung Chen

    2010-07-01

    Full Text Available Unsteady gait was noted in a 2-year-old boy with a lumboperitoneal (LP shunt that had been inserted 1 year earlier for increased head circumference caused by communicating hydrocephalus. Scoliosis was also noted during postoperative follow-up. Magnetic resonance imaging revealed new hindbrain tonsillar herniation and an extensive syrinx from C3 to L1. The malfunctioning LP shunt was removed and posterior fossa decompression with ventriculoperitoneal shunt insertion was performed. The unsteady gait recovered completely and scoliosis improved. Magnetic resonance imaging demonstrated resolution of the syrinx and tonsillar herniation. Acquired Chiari I malformation after LP shunt is well documented; usually, patients have no symptoms. This is the first report to have all the cause and effect mechanisms among syringomyelia, scoliosis and Chiari I malformation in 1 patient. We review the literature and discuss the possible mechanisms.

  9. Optimization methods for the Train Unit Shunting Problem

    DEFF Research Database (Denmark)

    Haahr, Jørgen Thorlund; Lusby, Richard Martin; Wagenaar, Joris Camiel

    2017-01-01

    We consider the Train Unit Shunting Problem, an important planning problem for passenger railway operators. This problem entails assigning train units from shunting yards to scheduled train services in such a way that the resulting operations are without conflicts. The problem arises at every...... shunting yard in the railway network and involves matching train units to arriving and departing train services as well as assigning the selected matchings to appropriate shunting yard tracks. We present an extensive comparison benchmark of multiple solution approaches for this problem, some of which...... are novel. In particular, we develop a constraint programming formulation, a column generation approach, and a randomized greedy heuristic. We compare and benchmark these approaches with two existing methods, a mixed integer linear program and a two-stage heuristic. The benchmark contains multiple real...

  10. Epidural haematoma: pathophysiological significance of extravasation and arteriovenous shunting

    International Nuclear Information System (INIS)

    Habash, A.H.; Sortland, O.; Zwetnow, N.N.

    1982-01-01

    35 patients with epidural bleeding operated on at Rikshospitalet, Oslo, during the period 1965 - 1980 had preoperative angiography with visualization of the external carotid artery. Twenty-one patients had extravasation of contrast medium from meningeal arteries. Seventeen of the 21 had also shunting of contrast medium from meningeal arteries to meningeal or diploic veins, while 20 of the 21 also had bled from a ruptured meningeal artery at operation. It was further found that of 20 patients who deteriorated after trauma 18 had an epidural arteriovenous shunt or extravasation. Conversely, of 15 patients who improved after trauma 12 had no evidence of a shunt. The strong correlation between the clinical course and the occurrence of extravasation supports previous experimental and clinical data, indicating the epidural arteriovenous shunt to be a major factor in the pathophysiology and the outcome of epidural bleeding. (author)

  11. Clinical outcomes of temporary shunting for infants with cerebral pseudomeningocele.

    Science.gov (United States)

    Mattei, Tobias A; Sambhara, Deepak; Bond, Brandon J; Lin, Julian

    2014-02-01

    Although in the case of subdural collections temporary shunting has been suggested as a viable alternative for definitive drainage of the accumulated fluid until restoration of the normal CSF dynamics, there is no agreement on the best management strategy for pseudomeningocele. The authors performed a retrospective chart review in order to evaluate the clinical outcomes of infants temporarily shunted for pseudomeningocele without encephalocele at our institution (The University of Illinois at Peoria/Illinois Neurological Institute) in the period from 2004 to 2012. The epidemiological characteristics, clinical management, and final outcomes of such subpopulation were compared with a control group which received temporary shunting for subdural hematomas (SDH) during the same period. Four patients (100% male) ranging in age from 8.9 to 27.1 months (mean = 13.88) with pseudomeningocele and 17 patients (64.7% male) ranging in age from 1.9 to 11.8 months (mean = 4.15) with SDH were identified. Although the initial management included sequential percutaneous subdural tapping in 82% of the patients, all children ultimately failed such strategy, requiring either subdural-peritoneal (81% of the cases) or subgaleal-peritoneal (19% of the cases) shunting. The mean implant duration was 201 days for the pseudomeningocele group and 384 days for the SDH one. Mean post-shunt hospitalization was 2 days for patients with pseudomeningocele and 4 days for patients with SDH. There was no statistical difference in terms of complications, length of hospitalization post-shunting, or clinical outcomes between the patients with pseudomeningocele and those with SDH. Temporary shunting of infants with pseudo-meningocele constitutes a viable therapeutic alternative with favorable clinical outcomes and a low risk of shunt dependency similar to those of children with SDH.

  12. Cross-species functionality of pararetroviral elements driving ribosome shunting.

    Directory of Open Access Journals (Sweden)

    Mikhail M Pooggin

    Full Text Available BACKGROUND: Cauliflower mosaic virus (CaMV and Rice tungro bacilliform virus (RTBV belong to distinct genera of pararetroviruses infecting dicot and monocot plants, respectively. In both viruses, polycistronic translation of pregenomic (pg RNA is initiated by shunting ribosomes that bypass a large region of the pgRNA leader with several short (sORFs and a stable stem-loop structure. The shunt requires translation of a 5'-proximal sORF terminating near the stem. In CaMV, mutations knocking out this sORF nearly abolish shunting and virus viability. METHODOLOGY/PRINCIPAL FINDINGS: Here we show that two distant regions of the CaMV leader that form a minimal shunt configuration comprising the sORF, a bottom part of the stem, and a shunt landing sequence can be replaced by heterologous sequences that form a structurally similar configuration in RTBV without any dramatic effect on shunt-mediated translation and CaMV infectivity. The CaMV-RTBV chimeric leader sequence was largely stable over five viral passages in turnip plants: a few alterations that did eventually occur in the virus progenies are indicative of fine tuning of the chimeric sequence during adaptation to a new host. CONCLUSIONS/SIGNIFICANCE: Our findings demonstrate cross-species functionality of pararetroviral cis-elements driving ribosome shunting and evolutionary conservation of the shunt mechanism. We are grateful to Matthias Müller and Sandra Pauli for technical assistance. This work was initiated at Friedrich Miescher Institute (Basel, Switzerland. We thank Prof. Thomas Boller for hosting the group at the Institute of Botany.

  13. Treatment of Hydrocephalus Associated with Neurosarcoidosis by Multiple Shunt Placement

    OpenAIRE

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-01-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showe...

  14. Transluminal angioplasty of a stenotic surgical splenorenal shunt

    International Nuclear Information System (INIS)

    Beers, B. van; Roche, A.; Cauquil, P.

    1988-01-01

    A stenosis of a side-to-side splenorenal shunt was treated by percutaneous angioplasty two years after the performance of the shunt. After dilatation, there was a fall of the splenorenal pressure gradient from 28 to 17 cm H 2 O and good transanastomotic flow was re-estabilshed. As in other arterial and venous territories, angioplasty may be an interesting alternative to surgery. (orig.)

  15. Assessment Lumboperitoneal or Ventriculoperitoneal Shunt Patency by Radionuclide Technique: A Review Experience Cases

    International Nuclear Information System (INIS)

    Chiewvit, Sunanta; Nuntaaree, Sarun; Kanchaanapiboon, Potjanee; Chiewvit, Pipat

    2014-01-01

    Hydrocephalus-related symptoms that worsen after shunt placement may indicate a malfunctioning or obstructed shunt. The assessment of shunt patency and site of obstruction is important for planning of treatment. The radionuclide cerebrospinal fluid (CSF) shunt study provides a simple, effective, and low-radiation-dose method of assessing CSF shunt patency. The radionuclide CSF shuntography is a useful tool in the management of patients presenting with shunt-related problems not elucidated by conventional radiological examination. This article described the imaging technique of ventriculoperitoneal (VP) shunt and lumbar puncture (LP) shunt. The normal finding, abnormal finding of completed obstruction and partial obstruction is present by our cases experience. The radiopharmaceutical (Tc-99m diethylenetriaminepentaacetic acid) was injected via the reservoir for VP shunt and via lumbar puncture needle in subarachnoid space for LP shunt, then serial image in the head and abdominal area. The normal function of VP and LP shunt usually rapid spillage of the radioactivity in the abdominal cavity diffusely. The patent proximal tube VP shunt demonstrates ventricular reflux. The early image of patent LP shunt reveals no activity in the ventricular system contrast to distal LP shunt reveals early reflux of activity in the ventricular system. The completed distal VP and LP shunt obstruction show absence of tracer in the peritoneal area or markedly delayed appearance of abdominal activity. The partial distal VP and LP shunt obstruction recognized by slow transit or accumulation of tracer at the distal end or focal tracer in the peritoneal cavity near the tip of distal shunt. The images of the normal and abnormal CSF shunt as describe before are present in the full paper. Radionuclide CSF shuntography is a reliable and simple procedure for assessment shunt patency

  16. Resident-performed Ex-PRESS shunt implantation versus trabeculectomy.

    Science.gov (United States)

    Seider, Michael I; Rofagha, Soraya; Lin, Shan C; Stamper, Robert L

    2012-09-01

    To compare outcomes between resident-performed trabeculectomy and Ex-PRESS shunt implantation. A consecutive cohort of 36 Ex-PRESS shunt implantations and 57 trabeculectomies (1 eye/patient) performed by resident surgeons in their third year of ophthalmic training at the University of California, San Francisco and at the San Francisco Veterans Administration Hospital, under the supervision of a single glaucoma fellowship-trained surgeon were included in this study. Eyes with PRESS shunt groups at all follow-up points. On average, the Ex-PRESS shunt group required significantly less ocular antihypertensive medication to control IOP at 3 months postoperative (P=0.01), but no difference was found at 6 months or 1 year (all, P≥0.28). A larger proportion of Ex-PRESS shunt patients had good IOP control without medication at 3 (P=0.057) and 6 months (P=0.076) postoperatively. No difference was found in the rates of sight-threatening complications between groups (all, P≥0.22). In the hands of ophthalmology residents in their third year of training, the trabeculectomy and Ex-PRESS shunt implantation procedures perform comparably in terms of postoperative IOP control, reduction in patient dependence on ocular antihypertensive medications, and risk of complication in our population.

  17. Reactor containment

    International Nuclear Information System (INIS)

    Kawabe, Ryuhei; Yamaki, Rika.

    1990-01-01

    A water vessel is disposed and the gas phase portion of the water vessel is connected to a reactor container by a pipeline having a valve disposed at the midway thereof. A pipe in communication with external air is extended upwardly from the liquid phase portion to a considerable height so as to resist against the back pressure by a waterhead in the pipeline. Accordingly, when the pressure in the container is reduced to a negative level, air passes through the pipeline and uprises through the liquid phase portion in the water vessel in the form of bubbles and then flows into the reactor container. When the pressure inside of the reactor goes higher, since the liquid surface in the water vessel is forced down, water is pushed up into the pipeline. Since the waterhead pressure of a column of water in the pipeline and the pressure of the reactor container are well-balanced, gases in the reactor container are not leaked to the outside. Further, in a case if a great positive pressure is formed in the reactor container, the inner pressure overcomes the waterhead of the column of water, so that the gases containing radioactive aerosol uprise in the pipeline. Since water and the gases flow being in contact with each other, this can provide the effect of removing aerosol. (T.M.)

  18. Russian RERTR program as a part of Joint US DOE-RF MINATOM collaboration on elimination of the threat connected to the use of HEU in research reactors

    International Nuclear Information System (INIS)

    Arkhangelsky, N.

    2002-01-01

    The Russian RERTR Program started at the end of 70's, the final goal of the program is to eliminate supplies of HEU in fuel elements and assemblies for foreign research reactors that were designed according to Russian projects. Basic directions of the work include: completion of the development of the fuel elements and assemblies on a basis of uranium dioxide; development of the fuel on a basis of U-Mo alloy; and development of pin type fuel elements. Fuel assemblies of WWR-M2 type with LEU were developed and qualified for using in foreign research reactors that use such type of fuel assemblies. These assemblies are ready for the supplying several operating foreign research reactors. There are more than 20 sites in Eastern European countries, former Soviet republics and another countries that have big amount of Russian origin HEU in fresh and spent fuel. The problem of the shipment of SNF from sites of research reactors is also very important for domestic Russian research reactors. More than ten years from its beginning the Russian RERTR program developed practically independently from the international RERTR program and only at the begin of 90's the Russian specialists started to contact with foreign scientists and the exchange of the scientific information has become more intensive. In September 1994, representatives of Minatom and DOE signed a protocol of intent to reduce an enrichment of uranium in research reactors. The main aspects of collaboration involve: Several domestic Russian research reactors such as WWR-M, IR-8 and others were investigated from the point of view of possibility of reducing of enrichment; financial support of the program from US DOE which is insufficient. The important part of international collaboration is the import of Russian origin spent and fresh fuel of research reactors to Russia. In August 2002 an impressive result of the Russian-American collaboration with support of IAEA and with the help and assistance of Yugoslavian side was

  19. Programmable shunts and headphones: Are they safe together?

    Science.gov (United States)

    Spader, Heather S; Ratanaprasatporn, Linda; Morrison, John F; Grossberg, Jonathan A; Cosgrove, G Rees

    2015-10-01

    Programmable shunts have a valuable role in the treatment of patients with hydrocephalus, but because a magnet is used to change valve settings, interactions with external magnets may reprogram these shunts. Previous studies have demonstrated the ability of magnetic toys and iPads to erroneously reprogram shunts. Headphones are even more ubiquitous, and they contain an electromagnet for sound projection that sits on the head very close to the shunt valve. This study is the first to look at the magnetic field emissions of headphones and their effect on reprogrammable shunt valves to ascertain whether headphones are safe for patients with these shunts to wear. In this in vitro study of the magnetic properties of headphones and their interactions with 3 different programmable shunts, the authors evaluated Apple earbuds, Beats by Dr. Dre, and Bose QuietComfort Acoustic Noise Cancelling headphones. Each headphone was tested for electromagnetic field emissions using a direct current gaussmeter. The following valves were evaluated: Codman Hakim programmable valve, Medtronic Strata II valve, and Aesculap proGAV. Each valve was tested at distances of 0 to 50 mm (in 5-mm increments) from each headphone. The exposure time at each distance was 1 minute, and 3 trials were performed to confirm results at each valve setting and distance. All 3 headphones generated magnetic fields greater than the respective shunt manufacturer's recommended strength of exposure, but these fields did not persist beyond 5 mm. By 2 cm, the fields levels were below 20 G, well below the Medtronic recommendation of 90 G and the Codman recommendation of 80 G. Because the mechanism for the proGAV is different, there is no recommended gauss level. There was no change in gauss-level emissions by the headphones with changes in frequency and amplitude. Both the Strata and Codman-Hakim valves were reprogrammed by direct contact (distance 0 mm) with the Bose headphones. When a rotation component was added, all

  20. Test results of fault current limiter using YBCO tapes with shunt protection

    Energy Technology Data Exchange (ETDEWEB)

    Baldan, Carlos A; Lamas, Jerika S; Shigue, Carlos Y [Escola de Engenharia de Lorena, EEL USP, Lorena - SP (Brazil); Filho, Ernesto Ruppert, E-mail: cabaldan@gmail.co [Faculdade de Engenharia Eletrica, FEEC Unicamp, Campinas - SP (Brazil)

    2010-06-01

    A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper.

  1. Outcomes of systemic to pulmonary artery shunts in patients weighing less than 3 kg: analysis of shunt type, size, and surgical approach.

    Science.gov (United States)

    Myers, John W; Ghanayem, Nancy S; Cao, Yumei; Simpson, Pippa; Trapp, Katie; Mitchell, Michael E; Tweddell, James S; Woods, Ronald K

    2014-02-01

    To evaluate outcomes of systemic to pulmonary artery shunts (SPS) in patients weighing less than 3 kg with regard to shunt type, shunt size, and surgical approach. Patients weighing less than 3 kg who underwent modified Blalock-Taussig or central shunts with polytetrafluoroethylene grafts at our institution from January 1, 2000, to May 31, 2011, were reviewed. Patients who had undergone other major concomitant procedures were excluded from the analysis. Primary outcomes included mortality (discharge mortality and mortality before next planned palliative procedure or definitive repair), cardiac arrest and/or extracorporeal membrane oxygenation (ECMO), and shunt reintervention. In this cohort of 80 patients, discharge survival was 96% (77/80). Postoperative cardiac arrest or ECMO occurred in 6/80 (7.5%), and shunt reintervention was required in 14/80 (17%). On univariate analysis, shunt reintervention was more common in patients with 3-mm shunts (11/30, 37%) compared with 3.5-mm (2/36, 6%) or 4-mm shunts (1/14, 7%) (P approach and cardiac arrest/ECMO or mortality. Multiple logistic regression demonstrated that a shunt size of 3 mm (P = .019) and extracardiac anomaly (P = .047) were associated with shunt reintervention, whereas no variable was associated with cardiac arrest/ECMO or mortality. In this high-risk group of neonates weighing less than 3 kg at the time of SPS, survival to discharge and the next planned surgical procedure was high. Outcomes were good with the 3.5- and 4-mm shunts; however, shunt reintervention was common with 3-mm shunts. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  2. The Texts of the Instruments connected with the Agency's Assistance to Pakistan in Establishing a Research Reactor Project. A Second Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1968-01-12

    As a sequel to the assistance which the Agency provided to the Government of Pakistan in establishing a research reactor project, a second Supply Agreement has been concluded between the Agency and the Governments of Pakistan and the United States of America. This Agreement entered into force on 19 October 1967, and the text is reproduced herein for the information of all Members.

  3. The Texts of the Instruments connected with the Agency's Assistance to Yugoslavia in Establishing a Research Reactor Project. Second Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1968-08-28

    As a sequel to the assistance which the Agency provided to the Government of Yugoslavia in establishing a research reactor project, a second Supply Agreement has been concluded between the Agency and the Governments of the United States of America and Yugoslavia. The Agreement entered into force on 20 February 1968, and the text is reproduced herein for the information of all Members.

  4. The Texts of the Instruments connected with the Agency's Assistance to Finland in relation to a Research Reactor Project. Second Supply Agreement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-07-25

    As a sequel to the assistance which the Agency provided to the Government of Finland in establishing a research reactor project, a second Supply Agreement has been concluded between the Agency and the Government of Finland and the United States of America. This Agreement entered into force on 8 July 1966, and the text is reproduced herein for the information of all Members.

  5. The Texts of the Instruments connected with the Agency's Assistance to Pakistan in Establishing a Research Reactor Project. A Second Supply Agreement. An Amendment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1971-10-04

    The text of an Amendment to the Contract for the Transfer of Enriched Uranium for a Research Reactor (the Second Supply Agreement) between the Agency and the Governments of Pakistan and the United States of America is reproduced herein for the information of all Members. The Amendment entered into force on 16 June 1971.

  6. The Texts of the Instruments connected with the Agency's Assistance to Pakistan in Establishing a Research Reactor Project. A Second Supply Agreement

    International Nuclear Information System (INIS)

    1968-01-01

    As a sequel to the assistance which the Agency provided to the Government of Pakistan in establishing a research reactor project, a second Supply Agreement has been concluded between the Agency and the Governments of Pakistan and the United States of America. This Agreement entered into force on 19 October 1967, and the text is reproduced herein for the information of all Members

  7. The Texts of the Instruments connected with the Agency's Assistance to Yugoslavia in Establishing a Research Reactor Project. Second Supply Agreement

    International Nuclear Information System (INIS)

    1968-01-01

    As a sequel to the assistance which the Agency provided to the Government of Yugoslavia in establishing a research reactor project, a second Supply Agreement has been concluded between the Agency and the Governments of the United States of America and Yugoslavia. The Agreement entered into force on 20 February 1968, and the text is reproduced herein for the information of all Members

  8. The Texts of the Instruments connected with the Agency's Assistance to Finland in relation to a Research Reactor Project. Second Supply Agreement

    International Nuclear Information System (INIS)

    1966-01-01

    As a sequel to the assistance which the Agency provided to the Government of Finland in establishing a research reactor project, a second Supply Agreement has been concluded between the Agency and the Government of Finland and the United States of America. This Agreement entered into force on 8 July 1966, and the text is reproduced herein for the information of all Members

  9. A Modified Shunt System for the Management of Pyogenic Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Abdul Naveed Khan

    2017-01-01

    Full Text Available BACKGROUND: To describe the structure and efficacy of a modified cerebrospinal fluid (CSF shunt system with Bhatti CSF access chamber and ventriculoperitoneal shunt, for the management of hydrocephalus associated with pyogenic ventriculitis. METHODS: This was an observational study performed at the National Medical Center and Ziauddin Medical University, Karachi, Pakistan. Chemically bonded Bhatti CSF access chamber and ventriculoperitoneal shunt was inserted into 443 patients with hydrocephalus and pyogenic ventriculitis to allow injection of antibiotics into the lateral ventricles. RESULTS: In all patients, symptoms and signs of hydrocephalus were relieved immediately after shunt insertion and infection brought under control within two weeks of intraventricular injection of antibiotics (vancomycin or linezolid, via the CSF access chamber. In two patients peritoneal catheter was blocked by a precipitate of vancomycin. Reduction in the dose of intraventricular vancomycin from 50mg to 20mg and increased dilution (additional 2ml of 0.9% N/S solution prevented recurrence of this complication. All patients recovered from ventriculitis within two weeks of initiating this treatment. Follow-up was from 3 months to 2 years to monitor continued relief of hydrocephalus and absence of recurrence of ventriculitis. CONCLUSION: Bhatti CSF access chamber and the ventriculoperitoneal shunt is the only system available at present that fulfills the management of hydrocephalus associated with pyogenic ventriculitis. It provides continuous internal drainage of CSF combined with access to the ventricles for injection of antibiotics.

  10. Reactor System Design

    International Nuclear Information System (INIS)

    Chi, S. K.; Kim, G. K.; Yeo, J. W.

    2006-08-01

    SMART NPP(Nuclear Power Plant) has been developed for duel purpose, electricity generation and energy supply for seawater desalination. The objective of this project IS to design the reactor system of SMART pilot plant(SMART-P) which will be built and operated for the integrated technology verification of SMART. SMART-P is an integral reactor in which primary components of reactor coolant system are enclosed in single pressure vessel without connecting pipes. The major components installed within a vessel includes a core, twelve steam generator cassettes, a low-temperature self pressurizer, twelve control rod drives, and two main coolant pumps. SMART-P reactor system design was categorized to the reactor coe design, fluid system design, reactor mechanical design, major component design and MMIS design. Reactor safety -analysis and performance analysis were performed for developed SMART=P reactor system. Also, the preparation of safety analysis report, and the technical support for licensing acquisition are performed

  11. Reactors 2000: consultation on the technical and economical requirements connected with the possible realization of nuclear installations in Switzerland after the year 2000

    International Nuclear Information System (INIS)

    Haldi, P.A.

    1992-07-01

    In 1989 the OECD started a consultation on the development of nuclear reactors of small and medium size (SMR). The present study is part of the Swiss contribution to this international work. Beyond this primary goal, without being limited solely to SMRs, but exclusively in the Swiss framework, the study attempts to determine a profile for reactors which could be built in Switzerland after the year 2000. The study ''Reactors 2000'' is based on two polls which were conducted among about 70 persons from concerned professional circles (industry, utilities, scientific groups, energy policy makers, safety authorities, public organizations) in June 1990 and February 1991. A large majority of the persons interviewed think that - Switzerland should not jeopardize its energetic future by phasing out all activity in the nuclear field, based on circumstances which could be only temporary, - Switzerland should continue its activities in the nuclear field in order to maintain the necessary know-how and a sufficient number of highly qualified specialists both for the safe operation of the existing plants and for the continuation of the development of nuclear technology, - for future plants the goal of an even higher safety level should be aimed for, although, according to the explicit comments of many interviews, today's reactors are considered to be sufficiently safe, - future nuclear power plants should be designed in such a way that the possibility of a severe accident necessitating an evacuation of the Swiss population could be excluded, - Switzerland should participate in international projects, in order to maintain contact to the international development of nuclear technology; on the other hand, it should avoid any single-handed effort (including in the domain of small heating reactors). (author)

  12. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  13. Post V-P shunt surgical site EDH an uncommon complication: case report

    Directory of Open Access Journals (Sweden)

    Garg Manish

    2017-06-01

    Full Text Available ventriculoparitoneal shunt is well established modality of treatment for hydrocephalous. Complication of v-p shunt are also mentioned in literature like shunt infection shunt migration etc [8]. Here we are describing a rare complication of vp shunt which barely mentioned in literature. A 22 yr male admitted with complain of headache & vomiting patient was diagnosed to have tubercular meningities with hydrocephalous. Patient planned for ventriculoparietoneal shunt surgery and vp shunt was done. On 3rd post-surgery day patient develop weakness in Left side of body. Urgent ncct head done which showed EDH at surgical site. Immediate craniotomy and evacuation of hematoma was done patient improved and discharged. Thus we are discussing the importance of meticulous surgery for v-p shunt, post op ct scan and treatment.

  14. Flicker Mitigation of Grid Connected Wind Turbines Using STATCOM

    DEFF Research Database (Denmark)

    Sun, Tao; Chen, Zhe; Blaabjerg, Frede

    2004-01-01

    to the point of common coupling (PCC) to relieve the flicker produced by grid connected wind turbines and the corresponding control scheme is described in detail. Simulation results show that STATCOM is an effective measure to mitigate the flicker level during continuous operation of grid connected wind......Grid connected wind turbines may produce flicker during continuous operation. In this paper flicker emission of grid connected wind turbines with doubly fed induction generators is investigated during continuous operation. A STATCOM using PWM voltage source converter (VSC) is connected in shunt...

  15. Shunted-Josephson-junction model. II. The nonautonomous case

    DEFF Research Database (Denmark)

    Belykh, V. N.; Pedersen, Niels Falsig; Sørensen, O. H.

    1977-01-01

    The shunted-Josephson-junction model with a monochromatic ac current drive is discussed employing the qualitative methods of the theory of nonlinear oscillations. As in the preceding paper dealing with the autonomous junction, the model includes a phase-dependent conductance and a shunt capacitance....... The mathematical discussion makes use of the phase-space representation of the solutions to the differential equation. The behavior of the trajectories in phase space is described for different characteristic regions in parameter space and the associated features of the junction IV curve to be expected are pointed...... out. The main objective is to provide a qualitative understanding of the junction behavior, to clarify which kinds of properties may be derived from the shunted-junction model, and to specify the relative arrangement of the important domains in the parameter-space decomposition....

  16. Secondary pediatric encephalocele after ventriculosubgaleal shunting for posthemorrhagic hydrocephalus.

    Science.gov (United States)

    Seeburg, Daniel; Ahn, Edward; Huisman, Thierry

    2014-08-01

    Intraventricular hemorrhage and posthemorrhagic hydrocephalus continue to be common complications in very low-birth-weight premature infants, often requiring ventricular shunting for cerebrospinal fluid diversion. We report on two infants with posthemorrhagic hydrocephalus that developed a secondary encephalocele after ventriculosubgaleal shunting. Encephaloceles can act as a source of seizure activity and can result in various additional complications including meningitis, abscess formation, and infarction of herniated brain parenchyma. With continued improvements in neonatal intensive care, the survival of infants with significant medical comorbidities-including those that develop posthemorrhagic hydrocephalus requiring ventricular shunting-continues to increase. It is thus important for the radiologist and treating physician to be aware of this rare, potential complication. Georg Thieme Verlag KG Stuttgart · New York.

  17. Forty years of shunt surgery at Rigshospitalet, Denmark

    DEFF Research Database (Denmark)

    Mansson, Philip Kofoed; Johansson, Sofia; Ziebell, Morten

    2017-01-01

    Objective The objective of this study is to review our experience of shunt surgery by investigating 40years of development in terms of rates of revision and infection, shunt survival and risk factors. Design and participants Medical records and operative reports were reviewed retrospectively...... for all patients who underwent primary shunt surgery at our department in the years 2010 to 2012. All results were compared with a previous study from our department. A mixed population consisting of 434 patients was included. Adults (≥15years) accounted for 89.9% of all patients and the mean follow.......1-54.9). Within 4weeks postoperatively, 3.2% had an infection and overall infection rate was 5.5%. Short duration of surgery and the use of antibiotic prophylaxis were associated with a lower risk of infection. The most frequent causes of revision were valve defects (18.4%) and proximal defects or obstructions...

  18. Shunt impedance of spiral loaded resonant rf cavities

    International Nuclear Information System (INIS)

    Peebles, P.Z. Jr.; Parvarandeh, M.

    1975-01-01

    Based upon a treatment of the spiral loaded resonant radio frequency cavity as a shorted quarter-wave transmission line, a model for shunt impedance is developed. The model is applicable to loosely wound spirals in large diameter containers. Theoretical shunt impedance is given for spirals wound from tubing of circular or rectangular cross section. The former produces higher shunt impedance. Measurements made at Oak Ridge National Laboratory on 17 copper cavities are described which support the theoretical results. Theoretical results are also compared to data from twenty-three additional cavities measured at Los Alamos Scientific Laboratory. It is shown that the theoretical function forms a useful means of interpreting the quality of constructed cavities. (author)

  19. Treatment of hydrocephalus associated with neurosarcoidosis by multiple shunt placement.

    Science.gov (United States)

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-09-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showed an isolated fourth ventricle with both the inlet and outlet of fourth ventricle obstructed by recurrent neurosarcoidosis. Owing to the difficulty of using an endoscope, we performed neuronavigator-guided ventriculo-peritoneal shunting via the left lateral transcerebellar approach for the treatment of the isolated fourth ventricle with intravenous methyl prednisolone. The patient was discharged with improved neurological status.

  20. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    International Nuclear Information System (INIS)

    Jain, Deepak; Arora, Ankur; Deka, Pranjal; Mukund, Amar; Bhatnagar, Shorav; Jindal, Deepti; Kumar, Niteen; Pamecha, Viniyendra

    2013-01-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft

  1. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  2. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    Energy Technology Data Exchange (ETDEWEB)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, 3705 Fifth Avenue, Pittsburgh, PA 15213 (United States)

    1998-07-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.) With 1 fig., 7 refs.

  3. Study of short-lived fission products with the aid of an isotope separator connected to reactor R2-0

    International Nuclear Information System (INIS)

    Rudstam, G.

    1976-01-01

    This report constitutes a final report on project 74-3289 together with a preliminary report for project 75-3332. These projects have been included in the budget years 1974/75 and 1975/76 as a contribution to the operating costs of reactor R2-0 at Studsvik. The reactor was used for experimental studies on short-lived fission products with OSIRIS isotope-separator equipment. The scientific programme is very broad. It comprises, in the first place, characterisation of fission products (a study of their excitation levels, measurement of decay properties such as half-life and emission of delayed neutrons, determination of neutron energy spectrum, determination of total decay energy, etc.). An important application of this field of research is the determination of decay heat in nuclear fuel. The programme thus comprises research of a fundamental character and applied research. (H.E.G.)

  4. A nuclear reactor core fuel reload optimization using Artificial-Ant-Colony Connective Networks; Recarga de reatores nucleares utilizando redes conectivas de colonias de formigas artificiais

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Alan M.M. de; Schirru, Roberto [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: alan@lmp.ufrj.br; schirru@lmp.ufrj.br

    2005-07-01

    A Pressurized Water Reactor core must be reloaded every time the fuel burnup reaches a level when it is not possible to sustain nominal power operation. The nuclear core fuel reload optimization consists in finding a burned-up and fresh-fuel-assembly pattern that maximizes the number of full operational days. This problem is NP-hard, meaning that complexity grows exponentially with the number of fuel assemblies in the core. Besides that, the problem is non-linear and its search space is highly discontinual and multimodal. In this work a parallel computational system based on Ant Colony System (ACS) called Artificial-Ant-Colony Networks is introduced to solve the nuclear reactor core fuel reload optimization problem. ACS is a system based on artificial agents that uses the reinforcement learning technique and was originally developed to solve the Traveling Salesman Problem, which is conceptually similar to the nuclear fuel reload problem. (author)

  5. Problems and prospects connected with development of high-temperature filtration technology at nuclear power plants equipped with VVER-1000 reactors

    Science.gov (United States)

    Shchelik, S. V.; Pavlov, A. S.

    2013-07-01

    Results of work on restoring the service properties of filtering material used in the high-temperature reactor coolant purification system of a VVER-1000 reactor are presented. A quantitative assessment is given to the effect from subjecting a high-temperature sorbent to backwashing operations carried out with the use of regular capacities available in the design process circuit in the first years of operation of Unit 3 at the Kalinin nuclear power plant. Approaches to optimizing this process are suggested. A conceptual idea about comprehensively solving the problem of achieving more efficient and safe operation of the high-temperature active water treatment system (AWT-1) on a nuclear power industry-wide scale is outlined.

  6. Analysis of materials in connection with corium melt retention in WWER reactor vessels. Final report for the period 15 October 1995 - 14 October 1996

    International Nuclear Information System (INIS)

    Efanov, A.D.

    1997-02-01

    Analysis of the state of severe accident codes being developed in Russia describing processes of corium - reactor pressure vessel interaction during severe accidents showed that at present there is no reliable validated and verified code. This study considered some of the most advanced severe accident codes which include models of heat generating liquid convections and RPV tolerance capacity however the possibility of physico-chemical interactions is not being considered. The final report demonstrates one of the examples for the settlement modelling of processes of reactor core debris cooling and corium pool mirror cooling with the use of the KOSTER 2 Code developed at IPPE. It was shown that cooling by water spray within some definite region of drop dimensions (0.5 / 4 mm in diameter) could provide the opportunity of the WWER type RPV integrity preservation under the accepted conditions. Due to some uncertainties in calculation modules obtained results are recommended to be treated as preliminary. (author). 26 refs, figs, tabs

  7. Transjugular intrahepatic portosystemic shunt in patients with active variceal bleeding due to portal hypertension and portal vein thrombosis

    International Nuclear Information System (INIS)

    Shin, Hyun Woong; Ryeom, Hun Kyu; Lee, Sang Kwon; Lee, Jong Min; Kim, Young Sun; Suh, Kyung Jin; Kim, Tae Hun; Kim, Yong Joo

    1997-01-01

    To evaluate the feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in patients with active variceal bleeding due to liver cirrhosis and pre-existing portal vein thrombosis. Of a total of 123 patients who underwent TIPS, 14 patients with intractable variceal bleeding due to portal hypertension and portal vein thrombosis were included in this study. Noncavernomatous portal vein occlusion was seen in eight patients, and complete portal vein occlusion with cavernomatous trans-formation in six. For all patients, the methods used for TIPS placement were the same as those used in patients with patents portal veins. In seven of eight patients with noncavernomatous occlusion, right hepatic vein-right portal vein shunting was performed; in one with knoncavernomatous occlusion, a shunt was created between the right hepatic and left portal vein. In five of six patients with cavernomatous occlusion, the right hepatic and main portal vein were connected via a collateral vein. The procedures were technically successful in all except one patient. Immediate hemostatis was achieved after all technically successful procedures, and no significant complications were encountered. Minor complications were noted in six patients (three biliary tree punctures, one transperitoneal puncture, one splenic vein perforation, one hepatic subcapsular hematoma). TIPS is a technically feasible and hemodynamically effective procedure, even in patients with active variceal bleeding due to cirrhosis and complete portal vein occlusion

  8. Measurement of shunt amount using radionuclide angiocardiography: accuracy according to level of shunt and associated lesion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yang Min [Sejong General Hospital, Bucheon (Korea, Republic of)

    2006-08-15

    Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. The mean Qp/Qs was 1.83 {+-} 0.50 by radionuclide, and 1.74 {+-} 0.51 by oxymetry. The overall correlation coefficient was 0.86 ({rho} 0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44 and Bland-Altman range was 1.52, 0.74, 0.96, 1.57 and 1.50, respectively. There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

  9. Measurement of shunt amount using radionuclide angiocardiography: accuracy according to level of shunt and associated lesion

    International Nuclear Information System (INIS)

    Kim, Yang Min

    2006-01-01

    Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. The mean Qp/Qs was 1.83 ± 0.50 by radionuclide, and 1.74 ± 0.51 by oxymetry. The overall correlation coefficient was 0.86 (ρ 0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44 and Bland-Altman range was 1.52, 0.74, 0.96, 1.57 and 1.50, respectively. There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably

  10. Connecting numeric models

    International Nuclear Information System (INIS)

    Caremoli, C.; Erhard, P.

    1996-01-01

    Computerized simulation uses calculation codes whose validation is reliable. Reactor simulators should take greater advantage of latest computer technology impact, in particular in the field of parallel processing. Instead of creating more global simulation codes whose validation might be a problem, connecting several existing codes should be a promising solution. (D.L.). 3 figs

  11. Isolation and characterization of Salmonella typhimurium glyoxylate shunt mutants.

    OpenAIRE

    Wilson, R B; Maloy, S R

    1987-01-01

    Growth of Salmonella typhimurium on acetate as a sole carbon source requires expression of the glyoxylate shunt; however, the genes for the glyoxylate shunt enzymes have not been previously identified in S. typhimurium. In this study, we isolated transposon insertions in the genes for the two unique enzymes of this pathway, aceA (isocitrate lyase) and aceB (malate synthase). The aceA and aceB genes were located at 89.5 min on the S. typhimurium genetic map. Genetic linkage to nearby loci indi...

  12. Controversy about Management of Hydrocephalus - Shunt vs. Endoscopic Third Ventriculostomy.

    Science.gov (United States)

    Kumar, Vikas; Bodeliwala, Shaam; Singh, Daljit

    2017-08-01

    The best management of hydrocephalus is still controversial in the twenty-first century. Shunt treatment for hydrocephalus is the most common procedure performed in neurosurgical practice and is associated with the highest complications rate. But during the last 2 decades, the treatment of hydrocephalus has improved with better shunt devices available today, increased facilities for investigations and newer approaches like endoscopic third ventriculostomy. The recent advances in development of better endoscopes have provided the patient and treating doctor with an option for an alternative surgery for treatment of hydrocephalus.

  13. Cryptococcal cerebrospinal fluid shunt infection treated with fluconazole

    Directory of Open Access Journals (Sweden)

    Daniel Eymard

    1993-01-01

    Full Text Available A 37-year-old woman with a cadaveric renal allotransplantation required intra-cranial shunting devices after a presumptive episode of tuberculous meningitis. Six months later, she developed a culture-proven cryptococcal meningitis. Without having her ventriculo-auricular shunt removed, she was successfully treated with a short course of amphotericin B (335 mg and flucytosine (nine days followed by prolonged therapy with oral fluconazole (400 mg daily for 72 days. Three years post treatment she had no evidence of relapse, and normal renal graft function.

  14. Dosimetry work and calculations in connection with the irradiation of large devices in the high flux materials testing reactor BR2

    International Nuclear Information System (INIS)

    De Raedt, C.; Leenders, L.; Tourwe, H.; Farrar, H. IV.

    1982-01-01

    For about fifteen years the high flux reactor BR2 has been involved in the testing of fast reactor fuel pins. In order to simulate the fast reactor neutron environment most devices are irradiated under cadmium screen, cutting off the thermal flux component. Extensive neutronic calculations are performed to help the optimization of the fuel bundle design. The actual experiments are preceded by irradiations of their mock-ups in BR02, the zero power model of BR2. The mock-up irradiations, supported by supplementary calculations, are performed for the determination of the main neutronic characteristics of the irradiation proper in BR2 and for the determination of the corresponding operation data. At the end of the BR2 irradiation, the experimental results, such as burn-ups, neutron fluences, helium production in the fuel pin claddings, etc. are correlated by neutronic calculations in order to examine the consistency of the post-irradiation results and to validate the routine calculation procedure and cross-section data employed. A comparison is made in this paper between neutronic calculation results and some post-irradiation data for MOL 7D, a cadmium screened sodium cooled loop containing a nineteen fuel pin bundle

  15. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt.

    Science.gov (United States)

    Lutz, Barry R; Venkataraman, Pranav; Browd, Samuel R

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a "smart shunt" that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care.

  16. Successful Embolization of a Spontaneous Mesocaval Shunt Using the Amplatzer Vascular Plug II

    International Nuclear Information System (INIS)

    Boixadera, Helena; Tomasello, Alejandro; Quiroga, Sergi; Cordoba, Joan; Perez, Mercedes; Segarra, Antoni

    2010-01-01

    A 48-year-old man with alcoholic liver cirrhosis and hepatic encephalopathy was found to have a large, spontaneous mesocaval shunt. The shunt was successfully occluded with the use of an Amplatzer Vascular Plug. To our knowledge, this is the first report of the use of this device to embolize a mesocaval shunt involving the superior mesenteric vein.

  17. Posthemorrhagic Hydrocephalus in Newborns: Clinical Characteristics and Role of Ventriculoperitoneal Shunts

    Directory of Open Access Journals (Sweden)

    Inn-Chi Lee

    2009-02-01

    Conclusion: Patients who were shunt-dependent had worse neurodevelopmental outcomes and greater mortality than those without shunts. The results appeared to depend on how far the hydrocephalus had progressed and on the degree of IVH, but the necessity of VP shunts requires reevaluation before they are implanted.

  18. Shoulder tip pain: an under-reported complication of ventriculoperitoneal shunt.

    LENUS (Irish Health Repository)

    Lim, C

    2012-02-03

    Ventriculoperitoneal (VP) shunt insertion is the commonest form of treatment for hydrocephalus. Shoulder tip pain after VP shunt insertion is unusual and has only recently been reported. We present a case of excruciating shoulder tip pain due to diaphragmatic irritation after VP shunt insertion.

  19. Treatment of Occluded Distal Splenorenal Shunts with Endovascular Stents: A Report of Two Cases

    International Nuclear Information System (INIS)

    Lopez-Medina, Antonio; Peiro, Javier; Gonzalez de Garay, Miguel; Antonana, Miguel A.; Sustacha, Jon; Grande, Domingo

    2001-01-01

    Surgical treatment of an occluded or stenotic portosystemic shunt is difficult and carries a high risk of mortality. We report two cases of early thrombosis of distal splenorenal shunt (DSRS) successfully treated by transcatheter recanalization and stent placement. At 18-month follow-up, the patients remained asymptomatic and control venograms showed continued patency of the shunt with no evidence of stenosis or collaterals

  20. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  1. Nuclear reactor

    International Nuclear Information System (INIS)

    Shirakawa, Toshihisa.

    1979-01-01

    Purpose: To prevent cladding tube injuries due to thermal expansion of each of the pellets by successively extracting each of the control rods loaded in the reactor core from those having less number of notches, as well as facilitate the handling work for the control rods. Constitution: A recycle flow control device is provided to a circulation pump for forcibly circulating coolants in the reactor container and an operational device is provided for receiving each of the signals concerning number of notches for each of the control rods and flow control depending on the xenon poisoning effect obtained from the signals derived from the in-core instrument system connected to the reactor core. The operational device is connected with a control rod drive for moving each of the control rods up and down and a recycle flow control device. The operational device is set with a pattern for the aimed control rod power and the sequence of extraction. Upon extraction of the control rods, they are extracted successively from those having less notch numbers. (Moriyama, K.)

  2. Risk factors for shunt malfunction in pediatric hydrocephalus: a multicenter prospective cohort study.

    Science.gov (United States)

    Riva-Cambrin, Jay; Kestle, John R W; Holubkov, Richard; Butler, Jerry; Kulkarni, Abhaya V; Drake, James; Whitehead, William E; Wellons, John C; Shannon, Chevis N; Tamber, Mandeep S; Limbrick, David D; Rozzelle, Curtis; Browd, Samuel R; Simon, Tamara D

    2016-04-01

    OBJECT The rate of CSF shunt failure remains unacceptably high. The Hydrocephalus Clinical Research Network (HCRN) conducted a comprehensive prospective observational study of hydrocephalus management, the aim of which was to isolate specific risk factors for shunt failure. METHODS The study followed all first-time shunt insertions in children younger than 19 years at 6 HCRN centers. The HCRN Investigator Committee selected, a priori, 21 variables to be examined, including clinical, radiographic, and shunt design variables. Shunt failure was defined as shunt revision, subsequent endoscopic third ventriculostomy, or shunt infection. Important a priori-defined risk factors as well as those significant in univariate analyses were then tested for independence using multivariate Cox proportional hazard modeling. RESULTS A total of 1036 children underwent initial CSF shunt placement between April 2008 and December 2011. Of these, 344 patients experienced shunt failure, including 265 malfunctions and 79 infections. The mean and median length of follow-up for the entire cohort was 400 days and 264 days, respectively. The Cox model found that age younger than 6 months at first shunt placement (HR 1.6 [95% CI 1.1-2.1]), a cardiac comorbidity (HR 1.4 [95% CI 1.0-2.1]), and endoscopic placement (HR 1.9 [95% CI 1.2-2.9]) were independently associated with reduced shunt survival. The following had no independent associations with shunt survival: etiology, payer, center, valve design, valve programmability, the use of ultrasound or stereotactic guidance, and surgeon experience and volume. CONCLUSIONS This is the largest prospective study reported on children with CSF shunts for hydrocephalus. It confirms that a young age and the use of the endoscope are risk factors for first shunt failure and that valve type has no impact. A new risk factor-an existing cardiac comorbidity-was also associated with shunt failure.

  3. Optimal location of shunt FACTS devices in a power system with high wind feeding

    Energy Technology Data Exchange (ETDEWEB)

    Shakib, Arefeh Danesh; Balzer, Gerd [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power Systems

    2009-07-01

    Connections of large offshore wind farms, which will be placed in the North Sea, will lead to several problems in Germany's power system. One of these is the occurance of undervoltage at weak nodes due to the reduction of reactive power generation. This paper is covering several singular analyses of the system Jacobin matrix whose results are applied to identify sensors and weak places in power systems with high wind feeding. This allows for the solution of optimal location of shunt FACTS devices for example static var compensators (SVC) for voltage control. The optimizations are made on two parameters: the location of the devices and their sizes. Simulations are performed on a IEEE 57-bus system for several wind feeding scenarios. It can be shown that by use of optimal placed FACTS devices the voltage stability of the power system in the case of high wind feeding can be guaranteed. (orig.)

  4. A Decoupling Control Method for Shunt Hybrid Active Power Filter Based on Generalized Inverse System

    Directory of Open Access Journals (Sweden)

    Xin Li

    2017-01-01

    Full Text Available In this paper, a novel decoupling control method based on generalized inverse system is presented to solve the problem of SHAPF (Shunt Hybrid Active Power Filter possessing the characteristics of 2-input-2-output nonlinearity and strong coupling. Based on the analysis of operation principle, the mathematical model of SHAPF is firstly built, which is verified to be invertible using interactor algorithm; then the generalized inverse system of SHAPF is obtained to connect in series with the original system so that the composite system is decoupled under the generalized inverse system theory. The PI additional controller is finally designed to control the decoupled 1-order pseudolinear system to make it possible to adjust the performance of the subsystem. The simulation results demonstrated by MATLAB show that the presented generalized inverse system strategy can realise the dynamic decoupling of SHAPF. And the control system has fine dynamic and static performance.

  5. Left hemisphere structural connectivity abnormality in pediatric hydrocephalus patients following surgery.

    Science.gov (United States)

    Yuan, Weihong; Meller, Artur; Shimony, Joshua S; Nash, Tiffany; Jones, Blaise V; Holland, Scott K; Altaye, Mekibib; Barnard, Holly; Phillips, Jannel; Powell, Stephanie; McKinstry, Robert C; Limbrick, David D; Rajagopal, Akila; Mangano, Francesco T

    2016-01-01

    Neuroimaging research in surgically treated pediatric hydrocephalus patients remains challenging due to the artifact caused by programmable shunt. Our previous study has demonstrated significant alterations in the whole brain white matter structural connectivity based on diffusion tensor imaging (DTI) and graph theoretical analysis in children with hydrocephalus prior to surgery or in surgically treated children without programmable shunts. This study seeks to investigate the impact of brain injury on the topological features in the left hemisphere, contratelateral to the shunt placement, which will avoid the influence of shunt artifacts and makes further group comparisons feasible for children with programmable shunt valves. Three groups of children (34 in the control group, 12 in the 3-month post-surgery group, and 24 in the 12-month post-surgery group, age between 1 and 18 years) were included in the study. The structural connectivity data processing and analysis were performed based on DTI and graph theoretical analysis. Specific procedures were revised to include only left brain imaging data in normalization, parcellation, and fiber counting from DTI tractography. Our results showed that, when compared to controls, children with hydrocephalus in both the 3-month and 12-month post-surgery groups had significantly lower normalized clustering coefficient, lower small-worldness, and higher global efficiency (all p  hydrocephalus surgically treated with programmable shunts.

  6. Safety device for nuclear reactor

    International Nuclear Information System (INIS)

    Jacquelin, Roland.

    1977-01-01

    This invention relates to a safety device for a nuclear reactor, particularly a liquid metal (generally sodium) cooled fast reactor. This safety device includes an absorbing element with a support head connected by a disconnectable connector formed by the armature of an electromagnet at the end of an axially mobile vertical control rod. This connection is so designed that in the event of it becoming disconnected, the absorbing element gravity slides in a passage through the reactor core into an open container [fr

  7. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  8. A plasma polymerization technique to overcome cerebrospinal fluid shunt infections

    Czech Academy of Sciences Publication Activity Database

    Çökeliler, D.; Caner, H.; Zemek, Josef; Choukourov, A.; Biederman, H.; Mutlu, M.

    2007-01-01

    Roč. 2, č. 1 (2007), s. 39-47 ISSN 1748-6041 Grant - others:TUBITAK(TR) MISAG-COST 527 Institutional research plan: CEZ:AV0Z10100521 Keywords : shunt infections * cerebrospinal * PP HEMA * biomaterials Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.787, year: 2007

  9. Systemic Arterial-to-Pulmonary Artery Shunt Utilization

    African Journals Online (AJOL)

    multiruka1

    In certain circumstances, such as cyanotic neonates with tetralogy of Fallot (4) or cyanotic patients with. Tetralogy of Fallot and hypoplastic pulmonary arteries. (5), better outcomes are obtained if definitive surgery. (total correction or palliation) is preceded by creation of a systemic arterial-to-pulmonary artery shunt (SAPAS).

  10. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels ...

  11. k-Shortest routing of trains on shunting yards

    NARCIS (Netherlands)

    Riezebos, Jan; van Wezel, Wout

    2009-01-01

    We consider the problem of designing algorithmic support for k-best routing decisions in train shunting scheduling. A study at the Netherlands Railways revealed that planners like to interact with the solution process of finding suitable routes. Two types of interaction were required: the

  12. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts

    NARCIS (Netherlands)

    Van Den Bossche, Lindsay; Schoonenberg, Vivien A.C.; Burgener, Iwan A.; Penning, Louis C.; Schrall, Ingrid M.; Kruitwagen, Hedwig S.; Van Wolferen, Monique E.; Grinwis, Guy C.M.; Kummeling, Anne; Rothuizen, Jan; Van Velzen, Jeroen F.; Stathonikos, Nikolas; Molenaar, Martijn R.; Helms, Bernd J.; Brouwers, Jos F.H.M.; Spee, Bart; Van Steenbeek, Frank G.

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in

  13. Anatomical Evidence for Intracardiac Blood Shunting in Marine Turtles

    African Journals Online (AJOL)

    ... suggests that right to left intra-cardiac blood shunts may be a feature of diving in sea turtles; the sphincter providing a mechanism for the control of blood flow through the heart. The comparative anatomy of the pulmonary arteries of selected terrestrial reptiles suggests that a similar mechanism exists in non-diving species.

  14. Reversible Venting Stitch for Fenestrating Valve-less Glaucoma Shunts.

    Science.gov (United States)

    Akil, Handan; Vu, Priscilla Q; Nguyen, Anhtuan H; Nugent, Alexander; Chopra, Vikas; Francis, Brian A; Tan, James C

    2017-12-01

    The purpose of this is to describe a venting stitch modification for valveless glaucoma aqueous shunts and characterize early postoperative intraocular pressure (IOP) and glaucoma medication use following the modification. Retrospective chart review of 61 sequential patients undergoing Baerveldt glaucoma implant (BGI)-350 implantation at the Doheny Eye Institute. Twenty-four patients received a glaucoma shunt with venting stitch modification (modified BGI) and 37 patients received an unmodified shunt (BGI-only). IOP, number of glaucoma medications, and number of hypotony cases (intraocular pressure ≤5 mm Hg) were compared between the groups. T-tests were used for statistical analysis. At postoperative-day 1, mean IOP was significantly lower compared with preoperatively in the modified BGI group (14 mm Hg; reduced by 51%; P<0.0001) but not the BGI-only group (27 mm Hg; P=0.06). IOP difference between groups persisted till immediately before tube opening (P=0.005) and fewer IOP-lowering medications needed in the modified BGI group (P<0.0001). One case (4.2%) of postoperative hypotony was encountered with BGI modification, which resolved after the stitch was removed in clinic. The venting stitch valveless shunt modification allows for effective, reliable, and safe control of early postoperative IOP.

  15. Small-Diameter PTFE Portosystemic Shunts: Portocaval vs Mesocaval

    Directory of Open Access Journals (Sweden)

    Robert Shields

    1998-01-01

    Full Text Available Fifty-seven patients with failed sclerotherapy received a mesocaval interposition shunt with an externally supported, ringed polytetrafluoroethylene prosthesis of either 10 or 12 mm diameter. Thirty-one patients had Child-Pugh gradeA disease and 26 grade B; all had a liver volume of 1000– 2500 ml. Follow-up ranged from 16 months to 6 years 3 months. Three patients (5 per cent died in the postoperative period. There were two postoperative recurrences of variceal haemorrhage and one recurrent bleed in the second year after surgery. The cumulative shunt patency rate was 95 per cent and the incidence of encephalopathy 9 per cent; the latter was successfully managed by protein restriction and/or lactulose therapy. The actuarial survival rate for the whole group at 6 years was 78 per cent, for those with Child-Pugh grade A 88 per cent and for grade B 67 per cent. Small-lumen mesocaval interposition shunting achieves portal decompression, preserves hepatopetal flow, has a low incidence of shunt thrombosis, prevents recurrent variceal bleeding and is not associated with significant postoperative encephalopathy.

  16. Shunt impedance measurement of the APS BBC injector

    International Nuclear Information System (INIS)

    Sun, Y.E.; Lewellen, J.W.

    2006-01-01

    The injector test stand (ITS) at Advanced Photon Source (APS) presently incorporates a ballistic bunch compression (BBC) gun, and it is used as a beam source for a number of experiments, including THz generation, beam position monitor testing for the Linac Coherent Light Source (LCLS), novel cathode testing, and radiation therapy source development. The BBC gun uses three independently powered and phased rf cavities, one cathode cell, and two full cells to provide beam energies from 2 to 10 MeV with variable energy spread, energy chirp, and, to an extent, bunch duration. The shunt impedance of an rf accelerator determines how effectively the accelerator can convert supplied rf power to accelerating gradient. The calculation of the shunt impedance can be complicated if the beam energy changes substantially during its transit through a cavity, such as in a cathode cell. We present the results of direct measurements of the shunt impedance of the APS BBC gun on an individual cavity basis, including the cathode cell, and report on achieved gradients. We also present a comparison of the measured shunt impedance with theoretical values calculated from the rf models of the cavities.

  17. Temporary vascular shunting in vascular trauma: A 10-year review ...

    African Journals Online (AJOL)

    of a physiologically unstable patient requiring a damage control procedure, and in the ... ensure that the tubing would not fall out, but not so tight that the lumen of the .... Time to removal of the shunt represents a balance between removing the ...

  18. Congenital extrahepatic portosystemic shunt associated with heterotaxy and polysplenia

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley [Lucile Packard Children' s Hospital, Department of Radiology, Stanford University School of Medicine, Stanford, CA (United States); Feinstein, Jeffrey A. [Stanford University School of Medicine, Division of Pediatric Cardiology, Department of Pediatrics, Lucile Packard Children' s Hospital, Stanford (United States); Cohen, Ronald A.; Patel, Hitendra [Children' s Hospital and Research Center, Department of Diagnostic Radiology, Oakland, CA (United States); Feingold, Brian; Kreutzer, Jacqueline [Children' s Hospital of Pittsburgh, Department of Pediatrics, Division of Pediatric Cardiology, Pittsburgh, PA (United States); Chan, Fandics P. [Stanford University School of Medicine, Cardiovascular Imaging Section, Department of Radiology, Lucile Packard Children' s Hospital, Stanford, CA (United States)

    2010-07-15

    Heterotaxy with polysplenia is associated with many cardiovascular anomalies including the occasional occurrence of congenital extrahepatic portosystemic shunts (CEPS). Missing this anomaly can lead to inappropriate and ineffective therapy. To emphasize the importance and associated anatomy of CEPS in conjunction with heterotaxy with polysplenia. Review of three young children who presented with cyanosis and pulmonary hypertension without a cardiac etiology. They were known (1) or discovered (2) to have heterotaxy with polysplenia. There was absence of the intrahepatic inferior vena cava (IVC) with azygos or hemiazygos continuation in all three cases. In spite of normal liver function, they were discovered to have large portosystemic shunts, splenorenal in location, along with diffuse peripheral pulmonary arterial dilatation suggestive of CEPS (Abernethy malformation) with hepatopulmonary or, more accurately, portopulmonary syndrome. All CEPS were ipsilateral to the spleens. Patency of the portal veins in these cases allowed for percutaneous shunt closure with resolution of cyanosis. CEPS is associated with heterotaxy with polysplenia and can be symptomatic because of pulmonary arteriovenous (AV) shunting. Portal and hepatic vein patency are critical for determining feasibility of CEPS closure. (orig.)

  19. Effects of an interatrial shunt on rest and exercise hemodynamics

    DEFF Research Database (Denmark)

    Kaye, David; Shah, Sanjiv J; Borlaug, Barry A

    2014-01-01

    BACKGROUND: A treatment based on an interatrial shunt device has been proposed for counteracting elevated pulmonary capillary wedge pressure (PCWP) in patients with heart failure and mildly reduced or preserved ejection fraction (HFpEF). We tested the theoretical hemodynamic effects of this appro...

  20. Creating interatrial shunts in heart failure and pulmonary hypertension

    DEFF Research Database (Denmark)

    Wolsk, Emil; Gustafsson, Finn

    2016-01-01

    Patients with elevated filling pressures are at increased risk of adverse cardiovascular (CV) outcomes. Structural interventions to lower elevated either left or right atrial filling pressures are gaining attention. Studies in heart failure show that lowering left atrial pressure may reduce CV...... interatrial device shunt therapy a part of our armamentarium in patients with heart failure or pulmonary hypertension and increased filling pressure....

  1. Embolization of nonvariceal portosystemic collaterals in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Bilbao, Jose Ignacio; Arias, Mercedes; Longo, Jesus Maria; Alejandre, Pedro Luis; Betes, Maria Teresa; Elizalde, Arlette Maria

    1997-01-01

    Percutaneous embolization of large portosystemic collaterals was performed in three patients following placement of a transjugular intrahepatic portosystemic shunt in order to improve hepatopetal portal flow. Improved hepatic portal perfusion was achieved in these cases, thereby theoretically reducing the risk of chronic hepatic encephalopathy

  2. Global robust stability for shunting inhibitory CNNs with delays.

    Science.gov (United States)

    Wang, Lingna; Lin, Yiping

    2004-08-01

    In this paper, the problem of global robust stability for shunting inhibitory cellular neural networks (SICNNs) is studied. A sufficient condition guaranteeing the network's global robust stability is established. The result can easily be used to verify globally robust stable networks. An example is given to illustrate that the conditions of our results are feasible.

  3. Nuclear reactor

    International Nuclear Information System (INIS)

    Hattori, Sadao; Sekine, Katsuhisa.

    1987-01-01

    Purpose: To decrease the thickness of a reactor container and reduce the height and the height and plate thickness of a roof slab without using mechanical vibration stoppers. Constitution: Earthquake proofness is improved by filling fluids such as liquid metal between a reactor container and a secondary container and connecting the outer surface of the reactor container with the inner surface of the secondary container by means of bellows. That is, for the horizontal seismic vibrations, horizontal loads can be supported by the secondary container without providing mechanical vibration stoppers to the reactor container and the wall thickness can be reduced thereby enabling to simplify thermal insulation structure for the reduction of thermal stresses. Further, for the vertical seismic vibrations, verical loads can be transmitted to the secondary container thereby enabling to reduce the wall thickness in the same manner as for the horizontal load. By the effect of transferring the point of action of the container load applied to the roof slab to the outer circumferential portion, the intended purpose can be attained and, in addition, the radiation dose rate at the upper surface of the roof slab can be decreased. (Kamimura, M.)

  4. Reactor system

    International Nuclear Information System (INIS)

    Miyano, Hiroshi; Narabayashi, Naoshi.

    1990-01-01

    The represent invention concerns a reactor system with improved water injection means to a pressure vessel of a BWR type reactor. A steam pump is connected to a heat removing system pipeline, a high pressure water injection system pipeline and a low pressure water injection system pipeline for injecting water into the pressure vessel. A pump actuation pipeline is disposed being branched from a main steam pump or a steam relieaf pipeline system, through which steams are supplied to actuate the steam pump and supply cooling water into the pressure vessel thereby cooling the reactor core. The steam pump converts the heat energy into the kinetic energy and elevates the pressure of water to a level higher than the pressure of the steams supplied by way of a pressure-elevating diffuser. Cooling water can be supplied to the pressure vessel by the pressure elevation. This can surely inject cooling water into the pressure vessel upon loss of coolant accident or in a case if reactor scram is necessary, without using an additional power source. (I.N.)

  5. Nuclear reactors

    International Nuclear Information System (INIS)

    Matheson, J.E.

    1983-01-01

    A nuclear reactor has an upper and a lower grid plate. Protrusions project from the upper grid plate. Fuel assemblies having end fittings fit between the grid plates. An arrangement is provided for accepting axial forces generated during the operation of the nuclear reactor by the flow of the cooling medium and thermal expansion and irradiation-induced growth of the fuel assembly, which comprises rods. Each fuel assembly rests on the lower grid plate and its upper end is elastically supported against the upper grid plate by the above-mentioned arrangement. The arrangement comprises four (for example) torsion springs each having a torsion tube and a torsion bar nested within the torsion tube and connected at one end thereto. The other end of the torsion bar is connected to an associated one of four lever arms. The torsion tube is rigidly connected to the other end fitting and the springs are disposed such that the lever arms are biassed against the protrusions. (author)

  6. A new method for the measurement of intrahepatic shunts

    International Nuclear Information System (INIS)

    Hoefs, J.C.; Reynolds, T.B.; Pare, P.; Sakimura, I.

    1984-01-01

    After transhepatic portal pressure determination, 96 patients were assessed for the presence of intrahepatic shunts by injection of microspheres (25 +/- 5 micron diameter) into the portal vein using RISA-131I as an indicator of dilution. Multiple portal vein injections in each patient allowed blood sampling from the hepatic vein (site 1) and from two inferior vena cava sampling sites (site 2, at the junction of the hepatic vein orifice with the inferior vena cava, and site 3, 2 to 3 cm closer to or within the right atrium). Intrahepatic shunting was calculated from each site: hepatic vein in 57 patients and inferior vena cava, site 2 in 43 patients and site 3 in 77 patients. At least one valid IHS calculation was available in 92 of the patients. Intrahepatic shunting calculated from sequential portal vein injections with sampling from the hepatic vein was highly correlated (r . 0.98, p less than 0.0001, slope . 1.0), with a mean difference of 1.9% +/- 1.9%. There was no significant difference by t test comparison of the mean IHS calculated from sites 1, 2, and 3. Occasional marked discrepancies were noted between IHS calculated from site 1 or site 2 compared with site 3, and the site 3 calculation was always greater. A shunt index in all patients included shunts calculated from the hepatic vein in 57 patients plus shunt calculation from the inferior vena cava in the remaining patients (site 2 in 26 patients and site 3 in nine). The 82 patients with portal hypertension or chronic liver disease had a higher portal pressure, 13.8 +/- 4.6 mm Hg, and a significantly greater shunt index, 13.7% +/- 24.5% compared with controls. The frequency distribution of IHS in patients with chronic liver disease demonstrated less than 2% IHS in 49% of patients and less than 5% IHS in 63%. The validity of our methods and the implications of the infrequent demonstration of a large IHS are discussed

  7. Reactor container

    International Nuclear Information System (INIS)

    Ichiki, Tadaharu; Saba, Kazuhisa.

    1979-01-01

    Purpose: To improve the earthquake resistance as well as reduce the size of a container for a nuclear reactor with no adverse effects on the decrease of impact shock to the container and shortening of construction step. Constitution: Reinforcing profile steel materials are welded longitudinally and transversely to the inner surface of a container, and inner steel plates are secured to the above profile steel materials while keeping a gap between the materials and the container. Reactor shielding wall planted to the base concrete of the container is mounted to the pressure vessel, and main steam pipeways secured by the transverse beams and led to the outside of container is connected. This can improve the rigidity earthquake strength and the safetiness against the increase in the inside pressure upon failures of the container. (Yoshino, Y.)

  8. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt

    Science.gov (United States)

    Lutz, Barry R.; Venkataraman, Pranav; Browd, Samuel R.

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a “smart shunt” that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care. PMID:23653889

  9. Uterine perforation by a cystoperitoneal shunt, an unusual cause of recurrent vaginal discharge.

    Science.gov (United States)

    Poilblanc, Mathieu; Sentilhes, Loïc; Mercier, Philippe; Lefèbvre, Céline; Descamps, Philippe

    2012-01-01

    We describe the first reported case of uterine perforation by a cystoperitoneal shunt. The mechanism of this unusual complication is unclear. A 17-year-old patient had a cystoperitoneal shunt for a porencephalic cyst. She presented with recurrent watery vaginal discharge. A pelvic ultrasound examination showed that the uterus had been perforated by the distal tip of the shunt. The cystoperitoneal shunt was converted to a ventriculo-atrial shunt, and the vaginal discharge subsequently resolved. The appearance of light and clear vaginal discharge in a patient with a cystoperitoneal shunt raises the possibility of uterine perforation. This can be confirmed by ultrasound and analysis of the discharge. Removal of the shunt leads to spontaneous closure of the uterine defect.

  10. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    Bacterial infection is a major cause of shunt dysfunction. It is well-known that the majority of pathogenic micro-organisms are low-virulent bacteria normally found on intact skin. Probably shunts become contaminated during surgery either by contact to the patient skin, or contact from contaminated...... gloves or instruments. This study was performed to find out to what extent gloves become contaminated during shunt surgery. Gloves used during shunt implantation were examined in 10 operations. Shunt implantation was done using recommended precautions to avoid infection, including prophylactic...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  11. Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

    Science.gov (United States)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-01-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30%PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  12. Experimental comparison of piezoelectric and magnetostrictive shunt dampers

    Science.gov (United States)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-04-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (`piezoceramic') and PMN-30%PT (`single crystal') stacks, as well as a Tb0.3Dy0.7Fe1.92 (`Terfenol-D') rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  13. A variable current bypass shunt for electromagnets

    International Nuclear Information System (INIS)

    Berndt, M.M.; Lipari, J.J.

    1992-11-01

    An IGBT is used to control the current in bypass circuits that vary the relative strength of magnets connected in series. Each circuit consists of a water cooled assembly rated for continuous operation at 70 Volts and 0--50 Amperes DC, with 1 KV insulation between control/monitoring elements and magnets. The circuit operates as a 10KHz PWM switcher that includes filters and transient protection

  14. Nuclear reactor safety systems

    International Nuclear Information System (INIS)

    Ball, R.M.; Roberts, R.C.

    1980-01-01

    A safety system for shutting down a nuclear reactor under overload conditions is described. The system includes a series of parallel-connected computer memory type look-up tables each of which receives data on a particular reactor parameter and in each of which a precalculated functional value for that parameter is stored indicative of the percentage of maximum reactor load that the parameter contributes. The various functional values corresponding to the actual measured parameters are added together to provide a control signal used to shut down the reactor under overload conditions. (U.K.)

  15. Refueling of nuclear reactor

    International Nuclear Information System (INIS)

    Kaufmann, J.W.; Swidwa, K.J.; Hornak, L.P.

    1989-01-01

    This patent describes an apparatus for refueling a nuclear reactor, the reactor being disposed for refueling under water in a pit in a containment, the apparatus including a bridge to be mounted moveably over the pit on the containment, first means connected to the bridge, for moving the bridge forward and backward on the containment over the pit along a first path, a first pulse generator, connected to the moving means, responsive to the movement of the bridge, for producing pulses, means, connected to the generator,for counting the pulses, the count of the pulses being dependent on the distance of the movement of the bridge

  16. Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines.

    Science.gov (United States)

    Swetapadma, Aleena; Yadav, Anamika

    2015-01-01

    Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance.

  17. An experimental in-vivo canine model for adult shunt infection

    Directory of Open Access Journals (Sweden)

    Procop Gary

    2008-10-01

    Full Text Available Abstract Background Detailed human studies of the mechanisms and development of shunt infection in real time are not possible, and we have developed a canine hydrocephalus model to overcome this. The intention of this pilot study was to show that the canine hydrocephalus model could be shunted using conventional "human" shunts, and that a shunt infection could be established so that further studies could then be planned. Methods Hydrocephalus was induced in seven dogs (Canis familiaris by fourth ventricle obstruction. Four weeks later they were shunted using a Hakim Precision valve. Four of the dogs received shunts whose ventricular catheter had been inoculated with Staphylococcus epidermidis, and three were uninoculated controls. Four weeks after shunting the dogs were sacrificed and necropsy was performed. Removed shunts and tissue samples were examined microbiologically and isolates were subjected to detailed identification and genomic comparison. Results All the dogs remained well after shunting. Examination of removed shunt components revealed S. epidermidis in the brain and throughout the shunt system in the four inoculated animals, but in two of these Staphylococcus intermedius was also found. S. intermedius was also isolated from all three "negative" controls. There were slight differences between S. intermedius strains suggesting endogenous infection rather than cross- infection from a point source. Conclusion Shunt infection was established in the canine model, and had the experiment been extended beyond four weeks the typical microbiological, pathological and clinical features might have appeared. The occurrence of unplanned shunt infections in control animals due to canine normal skin flora reflects human clinical experience and underlines the usual source of bacteria causing shunt infection.

  18. Predicting ventriculoperitoneal shunt infection in children with hydrocephalus using artificial neural network.

    Science.gov (United States)

    Habibi, Zohreh; Ertiaei, Abolhasan; Nikdad, Mohammad Sadegh; Mirmohseni, Atefeh Sadat; Afarideh, Mohsen; Heidari, Vahid; Saberi, Hooshang; Rezaei, Abdolreza Sheikh; Nejat, Farideh

    2016-11-01

    The relationships between shunt infection and predictive factors have not been previously investigated using Artificial Neural Network (ANN) model. The aim of this study was to develop an ANN model to predict shunt infection in a group of children with shunted hydrocephalus. Among more than 800 ventriculoperitoneal shunt procedures which had been performed between April 2000 and April 2011, 68 patients with shunt infection and 80 controls that fulfilled a set of meticulous inclusion/exclusion criteria were consecutively enrolled. Univariate analysis was performed for a long list of risk factors, and those with p value < 0.2 were used to create ANN and logistic regression (LR) models. Five variables including birth weight, age at the first shunting, shunt revision, prematurity, and myelomeningocele were significantly associated with shunt infection via univariate analysis, and two other variables (intraventricular hemorrhage and coincided infections) had a p value of less than 0.2. Using these seven input variables, ANN and LR models predicted shunt infection with an accuracy of 83.1 % (AUC; 91.98 %, 95 % CI) and 55.7 % (AUC; 76.5, 95 % CI), respectively. The contribution of the factors in the predictive performance of ANN in descending order was history of shunt revision, low birth weight (under 2000 g), history of prematurity, the age at the first shunt procedure, history of intraventricular hemorrhage, history of myelomeningocele, and coinfection. The findings show that artificial neural networks can predict shunt infection with a high level of accuracy in children with shunted hydrocephalus. Also, the contribution of different risk factors in the prediction of shunt infection can be determined using the trained network.

  19. A comparison of micropore membrane inlet mass spectrometry-derived pulmonary shunt measurement with Riley shunt in a porcine model.

    Science.gov (United States)

    Duenges, Bastian; Vogt, Andreas; Bodenstein, Marc; Wang, Hemei; Böhme, Stefan; Röhrig, Bernd; Baumgardner, James E; Markstaller, Klaus

    2009-12-01

    The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model. However, agreement with a frequently used and accepted method for quantifying deficits in arterial oxygenation has not been established. We compared MMIMS-derived shunt (M-S) as a fraction of total cardiac output (CO) with Riley shunt (R-S) derived from the R-S formula in a porcine lung injury model. To allow a broad variance of atelectasis and therefore shunt fraction, 8 sham animals did not receive lavage, and 8 animals were treated by lung lavages with 30 mL/kg warmed lactated Ringer's solution as follows: 2 animals were lavaged once, 5 animals twice, and 1 animal 3 times. Variables were recorded at baseline and twice after induction of lung injury (T1 and T2). Retention data of sulfur hexafluoride, krypton, desflurane, enflurane, diethyl ether, and acetone were analyzed by MMIMS, and M-S was derived using a known algorithm for the multiple inert gas elimination technique. Standard formulas were used for the calculation of R-S. Forty-four pairs of M-S and R-S were recorded. M-S ranged from 0.1% to 35.4% and R-S from 3.7% to 62.1%. M-S showed a correlation with R-S described by linear regression: M-S = -4.26 + 0.59 x R-S (r(2) = 0.83). M-S was on average lower than R-S (mean = -15.0% CO, sd = 6.5% CO, and median = -15.1), with lower and upper limits of agreement of -28.0% and -2.0%, respectively. The lower and upper limits of the 95% confidence intervals were -17.0 and -13.1 (P < 0.001, Student's t-test). Shunt derived from MMIMS inert gas retention data correlated well with R-S during breathing of oxygen. Shunt as derived by MMIMS was generally less than R-S.

  20. What is the risk of infecting a cerebrospinal fluid-diverting shunt with percutaneous tapping?

    Science.gov (United States)

    Spiegelman, Lindsey; Asija, Richa; Da Silva, Stephanie L; Krieger, Mark D; McComb, J Gordon

    2014-10-01

    Most CSF-diverting shunt systems have an access port that can be percutaneously tapped. Tapping the shunt can yield valuable information as to its function and whether an infection is present. The fear of causing a shunt infection by tapping may limit the physician's willingness to do so. The authors of this study investigate the risk of infecting a shunt secondary to percutaneous tapping. Following institutional review board approval, CSF specimens obtained from tapping an indwelling CSF-diverting shunt during the 2011 and 2012 calendar years were identified and matched with clinical information. A culture-positive CSF sample was defined as an infection. If results were equivocal, such as a broth-only-positive culture, a repeat CSF specimen was examined. The CSF was obtained by tapping the shunt access port with a 25-gauge butterfly needle after prepping the unshaven skin with chlorhexidine. During the study period, 266 children underwent 542 shunt taps. With 541 taps, no clinical evidence of a subsequent shunt infection was found. One child's CSF went from sterile to infected 11 days later; however, this patient had redness along the shunt tract at the time of the initial sterile tap. The risk of infection from tapping a shunt is remote if the procedure is done correctly.

  1. Experiments on graphite block gaps connected with leak flow in bottom-core structure of experimental very high-temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Kikuchi, Kenji; Futakawa, Masatoshi; Takizuka, Takakazu; Kaburaki, Hideo; Sanokawa, Konomo

    1984-01-01

    In order to minimize the leak flow rate of an experimental VHTR (a multi-purpose very high-temperature gas-cooled reactor), the graphite blocks are tightened to reduce the gap distance between blocks by core restrainers surrounded outside of the fixed reflectors of the bottom-core structure and seal elements are placed in the gaps. By using a 1/2.75-scale model of the bottom-core structure, the experiments on the following items have been carried out: a relationship between core restraint force and block gap, a relationship between core restraint force and inclined angle of the model, leak flow characteristics of seal elements etc. The conclusions derived from the experiments are as follows: (1) Core restraint force is significantly effective for decreasing the gap distance between hot plenum blocks, but ineffective for the gap between hot plenum block and fixed reflector. (2) Graphite seal element reduces the leak flow rate from the top surface of hot plenum block into plenum region to one-third. (author)

  2. Nuclear reactors

    International Nuclear Information System (INIS)

    Prescott, R.F.; George, B.V.; Baglin, C.J.

    1979-01-01

    In a nuclear reactor (e.g. one having coolant down-flow through a core to a hearth below) thermal insulation (e.g. of a floor of the hearth) comprises a layer of bricks and a layer of tiles thereon, with smaller clearances between the tiles than between the bricks but with the bricks being of reduced cross-section immediately adjacent the tiles so as to be surrounded by interconnected passages, of relatively large dimensions, constituting a continuous chamber extending behind the layer of tiles. By this arrangement, lateral coolant flow in the inter-brick clearances is much reduced. The reactor core is preferably formed of hexagonal columns, supported on diamond-shaped plates each supported on a pillar resting on one of the hearth-floor tiles. Each plate has an internal duct, four upper channels connecting the duct with coolant ducts in four core columns supported by the plate, and lower channels connecting the duct to a downwardly-open recess common to three plates, grouped to form a hexagon, at their mutually-adjacent corners. This provides mixing, and temperature-averaging, of coolant from twelve columns

  3. Agreement of 27 February 1992 between the Government of the People's Democratic Republic of Algeria and the International Atomic Energy Agency for the application of safeguards in connection with the supply of a research reactor from the People's Republic of China

    International Nuclear Information System (INIS)

    1992-04-01

    The document reproduces the text of the Agreement of 27 February 1992 between the Government of the People's Democratic Republic of Algeria and the IAEA for the application of safeguards in connection with the supply of a 15 MW (thermal) research reactor from the People's Republic of China. The Agreement was approved by the Agency's Board of Governors on 25 February 1992

  4. Agreement of 27 February 1992 between the government of the People's Democratic Republic of Algeria and the International Atomic Energy Agency for the application of safeguards in connection with the supply of a research reactor from the People's Republic of China

    International Nuclear Information System (INIS)

    1992-07-01

    The document informs that the Agreement between the Government of the People's Democratic Republic of Algeria and the International Atomic Energy Agency for the Application of Safeguards in connection with the Supply of a Research Reactor from the People's Republic of China, which has been applied provisionally as from 27 February 1992, entered into force on 2 June 1992

  5. Water cooled nuclear reactor

    International Nuclear Information System (INIS)

    1975-01-01

    A description is given of a cooling water intake collector for a nuclear reactor. It includes multiple sub-collectors extending out in a generally parallel manner to each other, each one having a first end and a second one separated along their length, and multiple water outlets for connecting each one to a corresponding pressure tube of the reactor. A first end tube and a second one connect the sub-collector tubes together to their first and second ends respectively. It also includes multiple collector tubes extending transversely by crossing over the sub-collector tubes and separated from each other in the direction of these tubes. Each collector tubes has a water intake for connecting to a water pump and multiple connecting tubes separated over its length and connecting each one to the corresponding sub-collector [fr

  6. Nuclear reactor

    International Nuclear Information System (INIS)

    Jungmann, A.

    1975-01-01

    Between a PWR's reactor pressure vessel made of steel and the biological shield made of concrete there is a gap. This gap is filled up with a heat insulation facting the reactor pressure vessel, for example with insulating concrete segments jacketed with sheet steel and with an additional layer. This layer serves for smooth absorption of compressive forces originating in radial direction from the reactor pressure vessel. It consists of cylinder-segment shaped bricks made of on situ concrete, for instance. The bricks have cooling agent ports in one or several rows which run parallel to the wall of the pressure vessel and in alignment with superposed bricks. Between the layer of bricks and the biological shield or rather the heat insulation, there are joints which are filled, however, with injected mortar. That guarantees a smooth series of connected components resistant tom compression. Besides, a slip foil can be set between the heat insulation and the joining joint filled with mortar for the reduction of the friction at thermal expansions. (TK) [de

  7. Reactor container

    International Nuclear Information System (INIS)

    Hidaka, Masataka; Hatamiya, Shigeo; Kawasaki, Terufumi; Fukui, Toru; Suzuki, Hiroaki; Kataoka, Yoshiyuki; Kawabe, Ryuhei; Murase, Michio; Naito, Masanori.

    1990-01-01

    In order to suppress the pressure elevation in a reactor container due to high temperature and high pressure steams jetted out upon pipeway rupture accidents in the reactor container, the steams are introduced to a pressure suppression chamber for condensating them in stored coolants. However, the ability for suppressing the pressure elevation and steam coagulation are deteriorated due to the presence of inactive incondensible gases. Then, there are disposed a vent channel for introducing the steams in a dry well to a pressure suppression chamber in the reactor pressure vessel, a closed space disposed at the position lower than a usual liquid level, a first channel having an inlet in the pressure suppression chamber and an exit in the closed space and a second means connected by way of a backflow checking means for preventing the flow directing to the closed space. The first paths are present by plurality, a portion of which constitutes a syphon. The incondensible gases and the steams are discharged to the dry well at high pressure by using the difference of the water head for a long cooling time after the pipeway rupture accident. Then, safety can be improved without using dynamic equipments as driving source. (N.H.)

  8. An Adaptive Speed Control Approach for DC Shunt Motors

    Directory of Open Access Journals (Sweden)

    Ruben Tapia-Olvera

    2016-11-01

    Full Text Available A B-spline neural networks-based adaptive control technique for angular speed reference trajectory tracking tasks with highly efficient performance for direct current shunt motors is proposed. A methodology for adaptive control and its proper training procedure are introduced. This algorithm sets the control signal without using a detailed mathematical model nor exact values of the parameters of the nonlinear dynamic system. The proposed robust adaptive tracking control scheme only requires measurements of the velocity output signal. Thus, real-time measurements or estimations of acceleration, current and disturbance signals are avoided. Experimental results confirm the efficient and robust performance of the proposed control approach for highly demanding motor operation conditions exposed to variable-speed reference trajectories and completely unknown load torque. Hence, laboratory experimental tests on a direct current shunt motor prove the viability of the proposed adaptive output feedback trajectory tracking control approach.

  9. US and angiographic examination of brachial dialysis shunts

    International Nuclear Information System (INIS)

    Langer, R.; Langer, M.F.J.; Zwicker, C.; Wakat, J.P.; Treisch, J.

    1988-01-01

    In an experimental study, 13 bypass grafts and eight patches were evaluated. With PTFE-Vitagraft, IMPRA, and Microvel Haemashield grafts total reflection occurred, so that these grafts are not suitable for ultrasound (US) examination. In a prospective clinical trial 40 patients were examined with intraarterial digital subtraction angiography (DSA) and US of the hemodialysis shunts; for DSA, a contrast material with 150 mg/mL of iodine was used. The image quality was excellent in all cases, and no sensation of pain was reported, only a mild sensation of warmth during the injection. The evaluation of image quality for the sonographic investigation showed the following results: shunt artery, 74% excellent, 17% good, and 9% nondiagnostic; anastomosis, 70% excellent, 26% good, and 4% nondiagnostic; draining vein, 91% excellent and 9% good. US is a suitable screening procedure, and DSA can be performed preoperatively without major discomfort and with excellent image quality

  10. Management of intracranial dural arteriovenous shunts in adults

    International Nuclear Information System (INIS)

    Sarma, Dipanka; Brugge, Karel ter

    2003-01-01

    Dural arteriovenous shunts are abnormal arteriovenous communications within the dura. They are thought to be an acquired condition in adults and can present with a variety of clinical features, ranging from benign bruits to intracranial hemorrhage and neurological deficits. The presentation and natural history of these shunts is largely determined by the pattern of venous drainage. Knowledge of natural history and careful study of the angioarchitexture by angiography is therefore mandatory for correct management of these lesions. In this review, principles of management in adults and the various factors that influence treatment decisions are discussed, with a focus on endovascular therapy. Retrograde leptomeningeal or cortical venous drainage has a strong correlation with adverse clinical events and the requirement for aggressive management in this situation is highlighted. Indications for endovascular treatment, therapeutic goals, approaches and techniques are reviewed. The role of surgical treatment is also briefly discussed

  11. Endoscopic third ventriculostomy has no higher costs than ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Benicio Oton de Lima

    2014-07-01

    Full Text Available Objective: To evaluate the cost of endoscopic third ventriculostomy (ETV compared to ventriculoperitoneal shunt (VPS in the treatment of hydrocephalus in children. Method: We studied 103 children with hydrocephalus, 52 of which were treated with ETV and 51 with VPS in a prospective cohort. Treatment costs were compared within the first year after surgery, including subsequent surgery or hospitalization. Results: Twenty (38.4% of the 52 children treated with VPS needed another procedure due to shunt failure, compared to 11 (21.5% of 51 children in the ETV group. The average costs per patient in the group treated with ETV was USD$ 2,177,66±517.73 compared to USD$ 2,890.68±2,835.02 for the VPS group. Conclusions: In this series there was no significant difference in costs between the ETV and VPS groups.

  12. GABA shunt in the callus cells derived from soybean cotyledon

    Energy Technology Data Exchange (ETDEWEB)

    Tokunaga, M; Nakano, Y; Kitaoka, S [Osaka Prefectural Univ., Sakai (Japan). Coll. of Agriculture

    1975-01-01

    In the growing callus cells from soybean cotyledon, the activities of glutamate decarboxylase and GABA transaminase were increased in the early phase of the callus growth on the Miller agar medium. Succinate dehydrogenase activity was also changed in a similar manner. From these and the additional evidences that GABA transaminase was probably localized in the mitochondria, it has been made clear that the GABA shunt (GABA by-pass pathway) is operative and contributes to the respiratory metabolism in growing callus cells. Feeding young callus cells with GABA-U-/sup 14/C for 24 hr actually resulted in finding 53% of the taken up radioactivity in released carbon dioxide. Considerable parts of the taken up radioactivity were found in amino acids and proteins which should have been formed via the GABA shunt also.

  13. Anatomy and Classification of Gastrorenal and Gastrocaval Shunts

    Science.gov (United States)

    Sabri, Saher S.; Saad, Wael E. A.

    2011-01-01

    The gastric varices communicate with gastrorenal and gastrocaval shunts and are classified according to the pattern of venous inflow into three types, which differ in the number and location of the inflow veins. The gastric varices are also classified according to their venous drainage into four different types, reflecting the size and number of collateral veins communicating with the gastric varices and the gastrorenal/gastrocaval shunt. Lastly, the gastric varices are classified according to their appearance on balloon-occluded retrograde venography into five grades representing the degree of opacification of the gastric varices and the collateral veins. Understanding these anatomic classifications is crucial in planning endovascular obliteration of gastric varices. PMID:22942547

  14. Analysis and control of a shunt active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Ottersten, R.; Petersson, Andreas [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1999-09-01

    This report deals with active power filtering of low-frequency current harmonics. The active filter consists of a forced-commutated voltage source inverter with a digital control system. The aim of this master thesis is to investigate the performance of a shunt active power filter, and the parameters influence on the system performance. Three different harmonic identification methods are presented and compared. The shunt active power filter is very well suited for harmonic current reduction, provided that the phase shift due to the digital implementation of the control system is compensated. The performance of the active power filter depends on the switching frequency. When using individual harmonic detection methods the amount of compensation can be fully controlled for each current harmonic.

  15. Shunted-Josephson-junction model. I. The autonomous case

    DEFF Research Database (Denmark)

    Belykh, V. N.; Pedersen, Niels Falsig; Sørensen, O. H.

    1977-01-01

    The shunted-Josephson-junction model: the parallel combination of a capacitance, a phase-dependent conductance, and an ideal junction element biased by a constant current, is discussed for arbitrary values of the junction parameters. The main objective is to provide a qualitative understanding...... current-voltage curves are presented. The case with a time-dependent monochromatic bias current is treated in a similar fashion in the companion paper....

  16. Integrating rolling stock scheduling with train unit shunting

    DEFF Research Database (Denmark)

    Haahr, Jørgen Thorlund; Lusby, Richard Martin

    2017-01-01

    In this paper, we consider integrating two important railway optimization problems, in particular the Rolling Stock Scheduling Problem and the Train Unit Shunting Problem. We present two similar branch-and-cut based approaches to solve this integrated problem and, in addition, provide a comparison......, sequential approach ends in infeasibility. Furthermore, for the considered instances, solutions are typically found within a few minutes, indicating the applicability of the methodology to short-term planning....

  17. Pre-Liver Transplant: Tips Versus Distal Splenorenal Shunt

    Directory of Open Access Journals (Sweden)

    Thomas W. Faust

    1997-01-01

    Full Text Available Recurrent variceal bleeding in liver transplant candidates with end-stage liver disease can complicate or even prohibit a subsequent transplant procedure (OLT. Endoscopic sclero-therapy and medical therapy are considered as first-line management with surgical shunts reserved for refractory situations. Surgical shunts can be associated with a high mortality in this population and may complicate subsequent OLT. The transjugular intrahepatic portosystemic shunt (TIPS has been recommended in these patients as a bridge to OLT. This is a new modality that has not been compared with previously established therapies such as the distal splenorenal shunt (DSRS. In this study we report our experience with 35 liver transplant recipients who had a previous TIPS (18 patients or DSRS (17 patients for variceal bleeding. The TIPS group had a significantly larger proportion of critically ill and Child-Pugh C patients. Mean operating time was more prolonged in the DSRS group (P=0.014 but transfusion requirements were similar. Intraoperative portal vein blood flow measurements averaged 2132±725 ml/min in the TIPS group compared with 1120±351ml/min in the DSRS group (P<0.001. Arterial flows were similar. Mean ICU and hospital stays were similar. There were 3 hospital mortalities in the DSRS group and none in the TIPS group (P=0.1. We conclude that TIPS is a valuable tool in the management of recurrent variceal bleeding prior to liver transplantation. Intra0Perative hemodynamic measurements suggest a theoretical advantage with TIPS. In a group of patients with advanced liver disease we report an outcome that is similar to patients treated with DSRS prior to liver transplantation. The role of TIPS in the treatment of nontransplant candidates remains to be clarified.

  18. Almost periodic solution of shunting inhibitory CNNs with delays

    Science.gov (United States)

    Chen, Anping; Cao, Jinde

    2002-06-01

    Using the Banach fixed point theorem, we obtain a sufficient condition for the existence of almost periodic solution of shunting inhibitory cellular neural networks {dx ij}/{dt}=-a ijx ij- limit∑C kl∈N r(i,j) C ijklf x kl(t-τ) x ij+L ij(t), the global attractivity of SICNNs is also obtained. An example is given to illustrate that the condition of our results are feasible.

  19. A case of repeated intracerebral hemorrhages secondary to ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Jinbing Zhao

    2015-03-01

    Full Text Available Ventriculoperitoneal shunt is a routinely performed treatment in neurosurgical department. Intracerebral hemorrhage, as a complication after shunt catheterization, is really rare but with high mortality. In this study, we reported a case of a 74-year-old man who suffered from repeated intracerebral hemorrhage after ventriculoperitoneal shunt. The first hemorrhage happened 63 h after the 1st surgery, and most hematomas were located in the ipsilateral occipital lobe and intraventricles, along the ventricular catheter. Fresh blood clot casts blocked the external ventricular draining catheter, which was inserted into the right front horn during the 3rd surgery, indicating new intraventricular bleeding happened. A large hematoma in ipsilateral frontal lobe was detected on the 3rd day after the removal of external ventricular draining catheter. Different hemorrhagic locations and time points were encountered on the same case. We discussed the possible causes of repeated hemorrhage for this case, and the pre-operative preparation including risk evaluation in future clinical work.

  20. Retinal complications after aqueous shunt surgical procedures for glaucoma.

    Science.gov (United States)

    Law, S K; Kalenak, J W; Connor, T B; Pulido, J S; Han, D P; Mieler, W F

    1996-12-01

    To assess retinal complications and to identify risk factors for retinal complications following aqueous shunt procedures. Records of 38 consecutive aqueous shunt procedures that were performed on 36 patients at the Eye Institute of the Medical College of Wisconsin, Milwaukee, from June 1993 to March 1995 (minimum follow-up, 6 months) were reviewed. The mean +/- SD follow-up was 11.4 +/- 5.2 months (median, 10.5 months). Twelve patients (32%) had the following retinal complications: 4 serous choroidal effusions (10%) that required drainage, 3 suprachoroidal hemorrhages (8%), 2 vitreous hemorrhages (5%), 1 rhegmatogenous retinal detachment (3%), 1 endophthalmitis (3%), and 1 scleral buckling extrusion (3%). Surgical procedures for retinal complications were required in 8 (67%) of these 12 patients. Visual acuity decreased 2 lines or more in 9 (75%) of these 12 patients. The median onset of a postoperative retinal complication was 12.5 days, with 10 patients (83%) experiencing complications within 35 days. Serous choroidal effusions developed in 10 other patients (26%), and these effusions resolved spontaneously. Visual acuity decreased 2 lines or more in 2 (20%) of these additional 10 patients. Patients who experienced serious retinal complications were significantly older, had a higher rate of hypertension, and postoperative ocular hypotony. Serious retinal complications were distributed evenly among patients with Krupin valves with discs and Molteno and Baerveldt devices. Experience with the Ahmed glaucoma valve implant was limited. Aqueous shunt procedures may be associated with significant retinal complications and subsequent visual loss.

  1. Transmicrocatheter local injection of ethanol to treat hepatocellular carcinoma with high flow arteriovenous shunts

    International Nuclear Information System (INIS)

    Guan Shouhai; Shan Hong; Jiang Zaibo; Huang Mingsheng; Zhu Kangshun; Li Zhengran; Meng Xiaochun

    2002-01-01

    Objective: To evaluate the feasibility and clinical effect of embolization therapy in treating the high flow hepatic arteriovenous shunts in hepatocellular carcinoma (HCC) by locally injected ethanol through microcatheter. Methods: Forty-one branches of arteriovenous shunts were treated by local ethanol infusion through microcatheter in 29 patients suffered with HCC. Angiography was performed to observe the embolization effect and influence to non-targeted vessels. Result: Forty-one branches of arteriovenous shunts in 29 patients were injected with ethanol locally. Each single shunt was infused 1-6 times. The dose of ethanol was 2-3 ml per time, and the total dose of ethanol was 2-12 ml. All shunting tracts were embolized, and all non-target vessels were protected fluently. Iodine-oil deposition was well in continued TACE. Their syndromes were improved or disappeared. Conclusion: Transmicrocatheter injection of ethanol could safely and effectively treat the hepatic arteriovenous shunts and make advantages to TACE in HCC

  2. Valved or valveless ventriculoperitoneal shunting in the treatment of post-haemorrhagic hydrocephalus

    DEFF Research Database (Denmark)

    Andreasen, Trine Hjorslev; Holst, Anders Vedel; Lilja, Alexander

    2016-01-01

    BACKGROUND: Implant infection and obstruction are major complications for ventriculoperitoneal shunts in patients with post-haemorrhagic hydrocephalus. In an effort to (1) reduce the incidence of these complications, (2) reduce the rate of shunt failure and (3) shorten the duration of neurosurgical...... hospitalisation, we have implemented valveless ventriculoperitoneal shunts at our department for adult patients with post-haemorrhagic hydrocephalus and haemorrhagic cerebrospinal fluid at the time of shunt insertion. METHODS: All adult patients (>18 years old) treated for post-haemorrhagic hydrocephalus.......3 %, p = 0.02), but a higher rate of overdrainage (10.3 % vs 2.6 %, p = 0.04). CONCLUSION: The use of a valveless shunting for patients with post-haemorrhagic hydrocephalus results in shorter duration of neurosurgical hospitalisation and lower rate of shunt infection, although these advantages should...

  3. Laparoscopic assisted ventriculoperitoneal shunt revisions as an option for pediatric patients with previous intraabdominal complications

    Directory of Open Access Journals (Sweden)

    Fernanda O. de Carvalho

    2014-04-01

    Full Text Available Multiple shunt failure is a challenge in pediatric neurosurgery practice and one of the most feared complications of hydrocephalus. Objective: To demonstrate that laparoscopic procedures for distal ventriculoperitoneal shunt failure may be an effective option for patients who underwent multiple revisions due to repetitive manipulation of the peritoneal cavity, abdominal pseudocyst, peritonitis or other situations leading to a “non reliable” peritoneum. Method: From March 2012 to February 2013, the authors reviewed retrospectively the charts of six patients born and followed up at our institution, which presented with previous intra-peritoneal complications and underwent ventriculoperitoneal shunt revision assisted by video laparoscopy. Results: After a mean follow-up period of nine months, all patients are well and no further shunt failure was identified so far. Conclusion: Laparoscopy assisted shunt revision in children may be, in selected cases, an effective option for patients with multiple peritoneal complications due to ventriculo-peritoneal shunting.

  4. Resolution of Large Azygos Vein Aneurysm Following Stent-Graft Shunt Placement in a Patient with Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.; Cwikiel, Wojciech

    2006-01-01

    Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to the azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved

  5. Design strategy for the combined system of shunt passive and series active filters

    OpenAIRE

    Fujita, Hideki; Akagi, Hirofumi

    1991-01-01

    A design strategy for the combined power filter for a three-phase twelve-pulse thyristor rectifier is proposed. The shunt passive filter, which can minimize the output voltage of the series active filter, is designed and tested in a prototype model. A specially designed shunt passive filter makes it possible to reduce the required rating of the series active filter to 60% compared with a conventional shunt passive filter

  6. Phenotypic and chemotypic characterization of GABA-shunt mutants in Arabidopsis thaliana

    OpenAIRE

    Mekonnen, Dereje Worku

    2013-01-01

    Gamma-Aminobutyric acid (GABA) is a four carbon non protein amino acid, and the pathway that involves its production and degradation is called the GABA shunt. The GABA shunt is a short enzymatic pathway that involves three enzymes: glutamate decarboxylase (GAD), GABA transaminase (GABA-T) and succinic semi aldehyde dehydrogenase (SSADH). GABA shunt is conserved almost in all organisms studied so far. The pathway starts in the cytosol and finishes in mitochondria in higher organisms like plant...

  7. Emergency reactor shutdown device

    International Nuclear Information System (INIS)

    Ikehara, Morihiko.

    1982-01-01

    Purpose: To smoothen the emergency operation of the control rod in a BWR type reactor and to eliminate the external discharge of radioactively contaminated water. Constitution: A drain receiving tank is connected through a scram valve to the top of a cylinder which is containing a hydraulic piston connected to a trombone-shaped control rod and an accumulator is connected through another scram valve to the bottom of the cylinder. The respective scram valves are constructed to be opened by the reactor emergency shutdown signal from a reactor control system in such a manner that drain valve and a vent valve of the tank normally opened at the standby time are closed after approx. 10 seconds from the opening of the scram valves. In this manner, back pressure is not applied to the hydraulic piston at the emergency time, thereby smoothly operating the control rod. (Sikiya, K.)

  8. Haematology and coagulation profiles in cats with congenital portosystemic shunts.

    Science.gov (United States)

    Tzounos, Caitlin E; Tivers, Michael S; Adamantos, Sophie E; English, Kate; Rees, Alan L; Lipscomb, Vicky J

    2017-12-01

    Objectives The objectives of this study were, first, to report the haematological parameters and coagulation times for cats with a congenital portosystemic shunt (CPSS) and the influence of surgical shunt attenuation on these parameters; and, second, to identify any association between prolongation in coagulation profiles and incidence of perioperative haemorrhage. Methods This was a retrospective clinical study using client-owned cats with a CPSS. Signalment, shunt type (extra- or intrahepatic), degree of shunt attenuation (complete or partial), haematological parameters, prothrombin time (PT) and activated partial thromboplastin time (aPTT) test results, and occurrence of any perioperative clinical bleeding complications were recorded for cats undergoing surgical treatment of a CPSS at the Royal Veterinary College, UK, between 1994 and 2011. Results Forty-two cats were included. Thirty-six (85.7%) had an extrahepatic CPSS and six (14.3%) had an intrahepatic CPSS. Preoperatively, mean cell volume (MCV) and mean cell haemoglobin (MCH) were below the reference interval (RI) in 32 (76.2%) and 31 (73.8%) cats, respectively. Red blood cell count and mean cell haemoglobin concentration (MCHC) were above the RI in 10 (23.8%) and eight (19.1%) cats, respectively. Postoperatively, there were significant increases in haematocrit ( P = 0.044), MCV ( P = 0.008) and MCH ( P = 0.002). Despite the significant increase in MCV postoperatively, the median MCV postoperatively was below the RI, indicating persistence of microcytosis. Preoperatively, PT was above the upper RI in 14 cats (87.5%), and aPTT was above the upper RI in 11 cats (68.8%). No cat demonstrated a perioperative clinical bleeding complication. Conclusions and relevance Cats with a CPSS are likely to present with a microcytosis, but rarely present with anaemia, leukocytosis or thrombocytopenia. Surgical attenuation of the CPSS results in a significant increase in the HCT and MCV. Coagulation profiles in cats with a

  9. Connecting Grammaticalisation

    DEFF Research Database (Denmark)

    Nørgård-Sørensen, Jens; Heltoft, Lars; Schøsler, Lene

    morphological, topological and constructional paradigms often connect to form complex paradigms. The book introduces the concept of connecting grammaticalisation to describe the formation, restructuring and dismantling of such complex paradigms. Drawing primarily on data from Germanic, Romance and Slavic...

  10. Alternative breeder reactor technologies

    International Nuclear Information System (INIS)

    Spinrad, B.I.

    1978-01-01

    The significance of employing breeder reactors to stretch the world resources of nuclear fuels is briefly discussed, and the various types of breeder concepts are described. General descriptions, advantages, and disadvantages of the liquid metal cooled fast breeder, gas cooled fast breeder, molten salt breeder, thermal breeders, and spectral-shift control reactors are presented. Aspects of safeguarding fissile material connected with breeder operation are examined. 31 references

  11. Intrahepatic porto-hepatic venous shunts in Rendu-Osler-Weber disease: imaging demonstration

    International Nuclear Information System (INIS)

    Matsumoto, Shunro; Mori, Hiromu; Yamada, Yasunari; Hayashida, Tomoko; Hori, Yuzo; Kiyosue, Hiro

    2004-01-01

    This study describes the imaging features of the intrahepatic portohepatic venous (PHV) shunt, which is a potential cause of portosystemic encephalopathy in Rendu-Osler-Weber disease. Six patients with Rendu-Osler-Weber disease (two men, four women; age range 42-73 years) were retrospectively studied. There were two from one family and three from another family. Of these patients, one was diagnosed with definitive portosystemic encephalopathy because of a psychiatric disorder. We retrospectively reviewed the radiological examinations, including abdominal angiography (n=6), three-phase dynamic helical computed tomography (CT; n=3), and conventional enhanced CT (n=1). In one patient, CT during angiography and CT angioportography were also performed. Evaluation was placed on the imaging features of intrahepatic PHV shunts. On angiography, intrahepatic PHV shunts showing multiple and small shunts <5 mm in diameter in an apparent network were detected in all patents. In two patients, a large shunt with a size of either 7 or 10 mm was associated. These intrahepatic PHV shunts were predominantly distributed in the peripheral parenchyma. Intrahepatic PHV shunts would be characterized by small and multiple shunts in an apparent network on the periphery with or without a large shunt. (orig.)

  12. Radiologic follow-up of the transjugular intrahepatic stent-shunt (TIPSS)

    International Nuclear Information System (INIS)

    Hansmann, H.J.; Noeldge, G.; Leutloff, U.; Radeleff, B.; Richter, G.M.

    2001-01-01

    The transjugular intrahepatic stent-shunt (TIPSS) is a well accepted minimal invasive therapy for complications of portal hypertension: recurrent variceal bleeding, refractory ascites and liver failure due to the Budd-Chiari syndrome. The high frequency of shunt stenoses and occlusions makes regular follow up examinations essential. Despite modern non invasive imaging methods direct portography still is the gold standard for shunt surveillance in TIPSS. Ultrasound is helpful to detect shunt dysfunction, but nevertheless its failure rate is considerable despite the use of contrast enhancers such as Levovist because of anatomic and physical limitations, particularly when TIPSS-tracts deep in the liver are present. Reintervention rates approach 90-100% after 24 months, with 100% in child's A patients with comparatively good liver function. However, a strict shunt surveillance program with early portography and reintervention when necessary guarantees high clinical success rates associated with very low rebleeding rates below 10%. Overall the secondary success rate is 80%. Secondary failures are mainly caused by lack of patient compliance during follow-up. In a subgroup of patients no shunt maturation is observed, requiring multiple shunt revisions. In cases of recurrent shunt occlusions an association with bile leaks is presumed. In selected cases patients with chronically recurrent shunt stenosis or occlusions may benefit from placement of TIPSS stent grafts. (orig.) [de

  13. Study on the Automatic Detection Method and System of Multifunctional Hydrocephalus Shunt

    Science.gov (United States)

    Sun, Xuan; Wang, Guangzhen; Dong, Quancheng; Li, Yuzhong

    2017-07-01

    Aiming to the difficulty of micro pressure detection and the difficulty of micro flow control in the testing process of hydrocephalus shunt, the principle of the shunt performance detection was analyzed.In this study, the author analyzed the principle of several items of shunt performance detection,and used advanced micro pressure sensor and micro flow peristaltic pump to overcome the micro pressure detection and micro flow control technology.At the same time,This study also puted many common experimental projects integrated, and successfully developed the automatic detection system for a shunt performance detection function, to achieve a test with high precision, high efficiency and automation.

  14. Embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy

    International Nuclear Information System (INIS)

    Sakurabayashi, Shin; Sezai, Shuichi; Yamamoto, Yoshihiro; Hirano, Masanori; Oka, Hiroshi

    1997-01-01

    Purpose. To evaluate the efficacy of embolization of portal-systemic shunts in cirrhotic patients with chronic recurrent hepatic encephalopathy (CRHE). Methods. Seven cirrhotic patients with CRHE refractory to medical treatment (3 men and 4 women, mean age 66 years) were studied. Five patients had splenorenal shunts, 1 had a gastrorenal shunt, and 1 had an intrahepatic portal vein-hepatic vein shunt. Shunt embolization was performed using stainless steel coils, with a percutaneous transhepatic portal vein approach in 4 patients and a transrenal vein approach in 3 patients. Results. After embolization, the shunt disappeared in 4 patients on either ultrasound pulsed Doppler monitoring or portography. Complications observed in the 7 patients were fever, transient pleural effusion, ascites, and mild esophageal varices. For 3-6 months after embolization, the 4 patients whose shunts disappeared showed minimal or no reappearance of a shunt, and had no recurrence of encephalopathy. The serum ammonia levels decreased and electroencephalograms also improved. One of the 4 patients, who developed mild esophageal varices, required no treatment. Treatment was effective in 3 of the 4 patients (75%) who underwent embolization via a transhepatic portal vein. Conclusion. Transvascular embolization of shunts improved the outcome in 4 of 7 patients. The most effective embolization was achieved via the percutaneous transhepatic portal vein approach

  15. PWR type reactor plant

    International Nuclear Information System (INIS)

    Matsuoka, Tsuyoshi.

    1993-01-01

    A water chamber of a horizontal U-shaped pipe type steam generator is partitioned to an upper high temperature water chamber portion and a lower low temperature water chamber portion. An exit nozzle of a reactor container containing a reactor core therein is connected to a suction port of a coolant pump by way of first high temperature pipelines. The exit port of the coolant pump is connected to the high temperature water chamber portion of the steam generator by way of second high temperature pipelines. The low temperature water chamber portion of the steam generator is connected to an inlet nozzle of the reactor container by way of the low temperature pipelines. The low temperature water chamber portion of the steam generator is positioned lower than the high temperature water chamber portion, but upper than the reactor core. Accordingly, all of the steam generator for a primary coolant system, coolant pumps as well as high temperature pipelines and low temperature pipelines connecting them are disposed above the reactor core. With such a constitution, there is no worry of interrupting core cooling even upon occurrence of an accident, to improve plant safety. (I.N.)

  16. LWR type reactor

    International Nuclear Information System (INIS)

    Kato, Kiyoshi.

    1993-01-01

    A water injection tank in an emergency reactor core cooling system is disposed at a position above a reactor pressure vessel. A liquid phase portion of the water injection tank and an inlet plenum portion in the reactor pressure vessel are connected by a water injection pipe. A gas phase portion of the water injection tank and an upper portion in the reactor pressure vessel are connected by a gas ventilation pipe. Hydraulic operation valves are disposed in the midway of the water injection pipe and the gas ventilation pipe respectively. A pressure conduit is disposed for connecting a discharge port of a main recycling pump and the hydraulic operation valve. In a case where primary coolants are not sent to the main recycling pump by lowering of a liquid level due to loss of coolants or in a case where the main recycling pump is stopped by electric power stoppage or occurrence of troubles, the discharge pressure of the main recycling pump is lowered. Then, the hydraulic operation valve is opened to release the flow channel, then, boric acid water in the water injection tank is sent into the reactor by a falling head, to lead the reactor to a scram state. (I.N.)

  17. PHOTOVOLTAIC BASED SHUNT ACTIVE FILTER FOR POWER QUALITY IMPROVEMENT USING ICOSΦ THEORY

    Directory of Open Access Journals (Sweden)

    VIJAYAKUMAR G.

    2015-11-01

    Full Text Available This paper presents an optimal operation of Photovoltaic based Shunt Active Filter as (PV-SAF for significant energy conservation, harmonic mitigation and reactive power compensation. When the PV system generates excessive or equal power required to the load demand, then the coordinating logic disconnects the service grid from the load and with a consequent reduction of panel tariff and global warming gasses. The PV module is connected to the DC side of SAF through the DC-DC converter. Converter switch is controlled by fuzzy based Perturb & Observe (P&O Maximum Power Point Tracking (MPPT algorithm and it eliminates the drawback in the conventional PV system. The reference currents are extracted by the Fuzzy logic controller based ICosΦ control strategy. This proposed PV-SAF, if connected at the terminals of a small industry or a home or a small enlightening institution can avoid the use of interruptible power supply and individual stabilizer. An emulation using MATLAB Simulink is presented to validate the advantage of the proposed system.

  18. Predictors of Shunt Dysfunction and Overall Survival in Patients with Variceal Bleeding Treated with Transjugular Portosystemic Shunt Creation Using the Fluency Stent Graft.

    Science.gov (United States)

    Wan, Yue-Meng; Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Li, Ying-Chun; Wu, Xi-Nan; Yang, Jin-Hui

    2018-01-16

    Transjugular intrahepatic portosystemic shunt (TIPS) is an established method for portal hypertension. This study was to investigate the long-term safety, technical success, and patency of TIPS, and to determine the risk factors and clinical impacts of shunt dysfunction. A total of 154 consecutive patients undergoing embolotherapy of gastric coronary vein and/or short gastric vein and TIPS creation were prospectively studied. Follow-up data included technical success, patency and revision of TIPS, and overall survival of patients. During the study, the primary and secondary technical success rates were 98.7% and 100%, respectively. Sixty-three patients developed shunt dysfunction, 30 with shunt stenosis and 33 with shunt occlusion. The cumulative 60-month primary, primary assisted, and secondary patency rates were 19.6%, 43.0%, and 93.4%, respectively. The cumulative 60-month overall survival rates were similar between the TIPS dysfunction group and the TIPS non-dysfunction group (68.6% vs. 58.6%, P = .096). Baseline portal vein thrombosis (P value of 8.5 had 77.8% sensitivity and 64.8% specificity. The long-term safety, technical success, and patency of TIPS were good; baseline portal vein thrombosis, use of bare stents, and PPG were significantly associated with shunt dysfunction; shunt dysfunction has little impact on patients' long-term survival because of high secondary patency rates. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Nuclear reactors

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-10-01

    After some remarks on the nuclear fuel, on the chain reaction control, on fuel loading and unloading, this article proposes descriptions of the design, principles and operations of different types of nuclear reactors as well as comments on their presence and use in different countries: pressurized water reactors (design of the primary and secondary circuits, volume and chemistry control, backup injection circuits), boiling water reactors, heavy water reactors, graphite and boiling water reactors, graphite-gas reactors, fast breeder reactors, and fourth generation reactors (definition, fast breeding). For these last ones, six concepts are presented: sodium-cooled fast reactor, lead-cooled fast reactor, gas-cooled fast reactor, high temperature gas-cooled reactor, supercritical water-cooled reactor, and molten salt reactor

  20. Reactor as furnace and reactor as lamp

    International Nuclear Information System (INIS)

    Goldanskii, V.I.

    1992-01-01

    There are presented general characteristics of the following ways of transforming of nuclear energy released in reactors into chemical : ordinary way (i.e. trough the heat, mechanical energy and electricity); chemonuclear synthesis ; use of high-temperature fuel elements (reactor as furnace); use of the mixed nγ-radiation of reactors; use of the radiation loops; radiation - photochemical synthesis (reactor as lamp). Advantage and disadvantages of all above variants are compared. The yield of the primary product of fixation of nitrogen (nitric oxide NO) in reactor with the high-temperature (above ca. 1900degC) fuel elements (reactor-furnace) can exceed W ∼ 200 kg per gram of burned uranium. For the latter variant (reactor-lamp) the yield of chemical products can reach W ∼ 60 kg. per gram of uranium. Such values of W are close to or even strongly exceed the yields of chemical products for other abovementioned variants and - what is particularly important - are not connected to the necessity of archscrupulous removal of radioactive contamination of products. (author)

  1. Reactor feedwater device

    International Nuclear Information System (INIS)

    Igarashi, Noboru.

    1986-01-01

    Purpose: To suppress soluble radioactive corrosion products in a feedwater device. Method: In a light water cooled nuclear reactor, an iron injection system is connected to feedwater pipeways and the iron concentration in the feedwater or reactor coolant is adjusted between twice and ten times of the nickel concentration. When the nickel/iron ratio in the reactor coolant or feedwater goes nearer to 1/2, iron ions are injected together with iron particles to the reactor coolant to suppress the leaching of stainless steels, decrease the nickel in water and increase the iron concentration. As a result, it is possible to suppress the intrusion of nickel as one of parent nuclide of radioactive nuclides. Further, since the iron particles intruded into the reactor constitute nuclei for capturing the radioactive nuclides to reduce the soluble radioactive corrosion products, the radioactive nuclides deposited uniformly to the inside of the pipeways in each of the coolant circuits can be reduced. (Kawakami, Y.)

  2. Experience and outcome of ventricular-atrial shunt: a multi centre study

    International Nuclear Information System (INIS)

    Akhtar, N.; Khan, A.A.; Yousaf, M.

    2015-01-01

    Ventriculoperitoneal (VP) shunt has been widely utilized in the treatment of hydrocephalus as a safe option but there is recent literature evidence that ventricularatrial (VA) shunt is not as notorious for its complications as proclaimed, to analyse and report our success with this procedure we conducted our study. Methods: A total of 64 patients undergoing VA shunting were included in this case series study conducted at RMC and Allied hospital Rawalpindi. The data was collected over a period of 4 years from, 1st June 2010 to 1st June 2015. Result: Our study included 64 patients who underwent a VA shunt for hydrocephalus. Their age ranged from 25 to 75 years. Most of the patients were females (60%). The following complications were observed with 2 (3.12%) patients having blockage of the shunt at the neck, 3 (4.68%) suffered from glomerulonephritis, 2 (3.1%) had post-operative neck hematoma, 4 (6.25 %) had wound infection, short lower end of the tube was found in 3 (4.68%), migrated lower end (into the subclavian) was seen in 1 (1.56%). Mortality was 1(1.56%). These results were comparable to other studies. Conclusion: Neurosurgeons have been doing a VA shunt as a second procedure, after a VP shunt when the need due to a complication was encountered. We however share our experience regarding ventriculo-atrial shunting, as first choice procedure, because of its low incidence of shunt blockage unlike VP shunt, which has high rate of shunt blockage and therefore warrants repeated surgeries. (author)

  3. Investigating PID Shunting in Polycrystalline Silicon Modules via Multiscale, Multitechnique Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Steven P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Moseley, John [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Norman, Andrew [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Johnston, Steven [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Al-Jassim, Mowafak M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stokes, Adam [Colorado School of Mines; Gorman, Brian [Colorado School of Mines

    2018-02-27

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis. By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.

  4. Endoscopic Third Ventriculostomy Instead of Shunt Revision in Children Younger Than 3 Years of Age.

    Science.gov (United States)

    Zhao, Rui; Shi, Wei; Yang, Haowei; Li, Hao

    2016-04-01

    Endoscopic third ventriculostomy (ETV) is a valuable option in the treatment of shunt failure, but no clinical data exist for young children. The aim of this study was to elucidate the role of ETV in patients younger than 3 years of age with shunt malfunction. A cohort of 37 patients younger than 3 years of age with shunt malfunction underwent ETV instead of shunt revision. Patients' preoperative condition and medical history were studied to determine the impact of a number of variables on outcome. The Fisher exact test was used to assess differences among groups. Median age at ETV was 21.6 months (8-36 months). Diagnosis was obstructive hydrocephalus in 24 patients and communicating hydrocephalus in 13. Median age at initial shunt placement was 3.2 months (10 days to 30 months). The etiology of shunt malfunction was obstruction (n = 27) or infection (n = 10). Overall ETV failure rate was 40.5% (15/37). Patients whose age at initial shunt placement was <6 months and/or who had a preterm birth history had higher relative rates of ETV failure. Other variables, including type of hydrocephalus, interval between initial shunt placement and ETV, history of intraventricular bleeding and/or infection, and etiology of shunt malfunction, did not significantly affect the final outcome. Patients younger than 3 years with obstructive or communicating hydrocephalus may benefit from ETV in the event of shunt malfunction and have about a 60% probability of becoming shunt free. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Exercise-induced arteriovenous intrapulmonary shunting in dogs.

    Science.gov (United States)

    Stickland, Michael K; Lovering, Andrew T; Eldridge, Marlowe W

    2007-08-01

    We have previously shown, using contrast echocardiography, that intrapulmonary arteriovenous pathways are inducible in healthy humans during exercise; however, this technique does not allow for determination of arteriovenous vessel size or shunt magnitude. The purpose of this study was to determine whether large-diameter (more than 25 microm) intrapulmonary arteriovenous pathways are present in the dog, and whether exercise recruits these conduits. Through the right forelimb, 10.8 million 25-microm stable isotope-labeled microspheres (BioPAL, Inc., Worcester, MA) were injected either at rest (n = 8) or during high-intensity exercise (6- 8 mph, 10-15% grade, n = 6). Systemic arterial blood was continuously sampled during and for 3 minutes after injection. After euthanasia, tissue samples were obtained from the heart, liver, kidney, and skeletal muscle. In addition, 25- and 50-microm microspheres were infused into four isolated dog lungs that were ventilated and perfused at constant pressures similar to exercise. Blood and tissue samples were commercially analyzed for the presence of microspheres. No microspheres were detected in the arterial blood or tissue samples from resting dogs. In contrast, five of six exercising dogs showed evidence of exercise-induced intrapulmonary arteriovenous shunting, as microspheres were detected in arterial blood and/or tissue. Furthermore, shunt magnitude was calculated to be 1.4 +/- 0.8% of cardiac output (n = 3). Evidence of intrapulmonary arteriovenous anastomoses was also found in three of four isolated lungs. Consistent with previous human findings, these data demonstrate that intrapulmonary arteriovenous pathways are functional in the dog and are recruited with exercise.

  6. Immunohistochemical analysis of restenotic tissue after transjugular portosystemic shunt

    International Nuclear Information System (INIS)

    Lu Qin; An Yanli; Deng Gang; Fang Wen; Zhu Guangyu; Li Guozhao; Wei Xiaoying; Liu Yuanyuan; Teng Gaojun

    2005-01-01

    Objective: To investigate the changes of several restenotic tissue elements after transjugular portosystemic shunt, and to provide more informations for the mechanism of TIPS restenosis. Methods: TIPS was performed in 6 swine to set up TIPS animal models. 14-21 days after operation, the models were sacrificed to obtain the TIPS tissues for pathological examinations, including electric microscope, HE staining, and immunohistochemical staining of anti-SMC-actin-α, PCNA, Vementin, myoglobulin, eNOS and iNOS. Then , the results were comparatively analyzed between TIPS obstructed shunt tissues and non-obstructed shunt tissues. Results: Restenosis was occurred with different degrees in 4 swine of the 6 TIPS models. Electric microscopic results showed that the restenosis tissues were composed of over proliferated collagen, SMCs and fibroblasts. Anti-SMC-actin-α and PCNA were strongly positive expression in restenotic tissues, and also positive in patent tissues. Vimentin expressed strongly in unstenotic tissues, on the contrary, it expressed obviously weaker in restenotic tissues. Myoglobulin expressed more strongly in restenotic tissues and weakened in unstenotic tissues. eNOS expressed positive in normal liver tissues, and expressed weaker near TIPS restenotic tissues. iNOS showed stronger expression in restenotic tissues and could hardly expressed in normal liver tissues. Conclusions: Restenotic rate may be 67% in TIPS swine models. Restenotic tissues may be mainly composed of proliferated SMCs positively expressed anti-SMC-actin-α with strong ability of movement. eNOS may be expressed in normal liver tissues and instead iNOS be expressed in strongly injured liver tissues. (authors)

  7. Clinical results of the transjugular intrahepatic portosystemic shunt

    Energy Technology Data Exchange (ETDEWEB)

    Park, Auh Whan; Sim, Jae In; Ryeom, Hun Kyu; Kim, Yong Joo [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    1994-04-15

    To evaluate the clinical results of transjugular intrahepatic portosystemic shunt(TIPS) for the control of variceal bleeding. TIPS creation was attempted in 23 patients with endoscopically confirmed variceal bleeding. Most patients had multiple episodes of bleeding in the past and have been treated with multiple endoscopic sclerotherapies. Pre-and post-procedural hepatic and portal vein pressures were measured. After creation of TIPS patients were followed up at regular intervals. TIPS has been successfully accomplished in 22 of 23 patients using Wallstent(n = 21) and Strecker stent(n = 1). Immediate bleeding control was achieved in all patients with shunt creation. No procedure-related complication was noted. Portal vein pressure was reduced from 30.7 {+-} 5.8 mmHg to 20.8 {+-} 4.7 mmHg. The mean pressure gradient of portosystemic shunt dropped from 22.8 {+-} 6.0 prior to TIPS to 12.2 {+-} 4.1 immediately after. During the follow-up period (6-556 days, mean; 10 months), seven patients died; progressive hepatic failure (n 4), variceal rebleeding (n = 2), and respiratory failure(n = 1). Hepatic encephalopathy after TIPS was noted in 7 patients(31.8%). Variceal rebleeding occurred in 3 patients(13.6%). The remaining 15 patients have survived an average of 11 months. This results suggest that TIPS is a safe and effective method for lowering portal pressure and controlling variceal bleeding. Furthermore if these initial results are encouraged by further long-term observation, TIPS could replace endoscopic and risky surgical intervention.

  8. Case of right atrial myxoma with right to left shunt

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Kenji; Suzuki, Tomoyuki; Ohzeki, Tetsuro (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1982-12-01

    A case of 49-year-old woman with right atrial myxoma resulting to right to left shunt, diagnosed by cardiac pool isotope image, was reported. She was admitted to our clinic because of progressive shortness of breath. At admission lip cyanosis was noted. Laboratory data included polycythemia, low O/sub 2/ saturation (89%) and high erythrocyte sedimentation rate (65 mm/1 h). Chest x-p showed slight right atrial enlargement, but no pulmonary congestion. The electrocardiogram showed sinus regular rhythm with biphasic p wave in leads II, III, aVf. Although 1st heart sound at the apex was splited, no heart murmur was heard. In usual echocardiographic approach, no abnormal echogram was obtained in the right ventricular region. Lung perfusion scintiscan with Tc-99 m-MAA showed visualization of thyroid gland and kidney, which suggested intracardiac right-to-left shunt. Cardiac pool image with Tc-99m-HSA revealed large photo-deficient area in the right atrium and early visualization of aortic arch. Computor tomography showed large round low density region 8 x 7 cm in size. Based on their findings, this patient was diagnosed as right atrial tumor. At operation a large tumor (diameter 8 x 7 x 7 cm, weight 160g) filled the lower part of the right atrium and was adherent to the anterolateral wall in the right atrium. As a cause of R-L shunt, streched foramen ovale (5 x 10 mm) was found. Tumor histology was typical of atrial myxoma. Post-operative gated cardiac isotope image showed no evidence of residual atrial tumor. Cardiac blood pool isotope imaging was a method for the noninvasive detection and assessment of right atrial myxoma.

  9. New fast reactor installation concept

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The large size and complexity of fast reactor installations are emphasised and these difficulties will be increased with the advent of fast reactors of higher power. In this connection a new concept of fast reactor installation is described with a view to reducing the size of the installation and enabling most components, including even the primary vessel, to be constructed within the confines of a workshop. Full constructional details are given. (U.K.)

  10. Shunting arc plasma source for pure carbon ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Koguchi, H.; Sakakita, H.; Kiyama, S.; Shimada, T.; Sato, Y.; Hirano, Y. [Energy Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2012-02-15

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA/mm{sup 2} at the peak of the pulse.

  11. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse.

  12. Ectopic cystoperitoneal shunt demonstrated by valvulography. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Jofre, M J; Sierralta, M P [Military Hospital Nuclear Medicine Department, Santiago (Chile)

    2002-09-01

    The most important and frequent complications in the management of hydrocephalus treated with a derivation system are the infection and obstruction of the ventriculoperitoneal or ventriculoatrial shunt. However, another less frequent problem is the migration of the distal catheter. The case report presented is a 20 year-old girl who started, when she was 12, with severe headaches and epileptogenic seizures. She was diagnosed with a left parietotemporal aracnoidal cyst and a cystoperitoneal shunt was installed. However, she continued to have headaches. In September 1999, the derivation system was controlled with a radionuclide valvulography, which demonstrated shunt patency, with mild ectasis in the distal region. In July 2000, another valvulography showed a malfunction of the cystoperitoneal system. The distal catheter was surgically reviewed and repositioned. A few months of being asymptomatic, the headaches returned with a cough, which didn't respond to treatment. In February of 2002, she was referred to the Military Hospital Nuclear Medicine Department and a radionuclide valvulography was performed with 370 MBq of Tc99m-DTPA, injected in the derivative system reservoir. Images showed a slow descension of the radionuclide until the xifoides region where the distal catheter had formed a loop into the chest. Free activity was observed at the end of the catheter with another abnormal traject in the middle chest up to the top of the sternum. A pumping test was done and the patient coughed and said that she 'felt water' in her mouth. A simple abdomen X-ray was performed confirming the distal catheter in the upper side of the diaphragm. A third surgery was performed demonstrating that the catheter had an intraperitoneal loop with the distal end in the chest. They pulled the catheter and the distal end was repositioned into the peritoneal cavity, controlling its functioning. A simple abdomen X-ray verified the position. In the following days the patient had no headache

  13. Ectopic cystoperitoneal shunt demonstrated by valvulography. A case report

    International Nuclear Information System (INIS)

    Jofre, M.J.; Sierralta, M.P.

    2002-01-01

    The most important and frequent complications in the management of hydrocephalus treated with a derivation system are the infection and obstruction of the ventriculoperitoneal or ventriculoatrial shunt. However, another less frequent problem is the migration of the distal catheter. The case report presented is a 20 year-old girl who started, when she was 12, with severe headaches and epileptogenic seizures. She was diagnosed with a left parietotemporal aracnoidal cyst and a cystoperitoneal shunt was installed. However, she continued to have headaches. In September 1999, the derivation system was controlled with a radionuclide valvulography, which demonstrated shunt patency, with mild ectasis in the distal region. In July 2000, another valvulography showed a malfunction of the cystoperitoneal system. The distal catheter was surgically reviewed and repositioned. A few months of being asymptomatic, the headaches returned with a cough, which didn't respond to treatment. In February of 2002, she was referred to the Military Hospital Nuclear Medicine Department and a radionuclide valvulography was performed with 370 MBq of Tc99m-DTPA, injected in the derivative system reservoir. Images showed a slow descension of the radionuclide until the xifoides region where the distal catheter had formed a loop into the chest. Free activity was observed at the end of the catheter with another abnormal traject in the middle chest up to the top of the sternum. A pumping test was done and the patient coughed and said that she 'felt water' in her mouth. A simple abdomen X-ray was performed confirming the distal catheter in the upper side of the diaphragm. A third surgery was performed demonstrating that the catheter had an intraperitoneal loop with the distal end in the chest. They pulled the catheter and the distal end was repositioned into the peritoneal cavity, controlling its functioning. A simple abdomen X-ray verified the position. In the following days the patient had no headache

  14. A Novel Method for the Current Harmonic Elimination of Industrial Power System Using Single Tuned Shunt Passive Filter

    Directory of Open Access Journals (Sweden)

    Mansoor Ahmed Soomro

    2012-01-01

    Full Text Available The automation of IPS (Industrial Power System has brought about several advantages of increased productivity and efficiency but it suffers from incompatible problems of overheating, noise, complexity etc, which disturb its smooth and fault tolerant implication. When the resonance condition is reached, these effects become detrimental and disturb the whole power system. The purpose of this research work is to include single tuned shunt type passive filter for harmonic elimination of the components used in industrial power system. For this purpose, MATLAB simulation using sim Power system tool has been used to analyze the effects of current harmonics. Third harmonic effects have been removed by the addition of six pulse converter technique. The simulation results show that implication of single tuned shunt (parallel connected passive filter removes effects of succeeding order current harmonics i.e. fifth, seventh and eleventh etc. which are causing substantial damage to industrial power system. The effects of current harmonics can be solved by installing without and with the application of proposed filter. Further, it is observed that these filters contribute in reduction of THD (Total Harmonic Current Distortion followed by improvement in power factor. These results are taken considering limits of IEEE 519-1992 standards.

  15. Damping Enhancement of Composite Panels by Inclusion of Shunted Piezoelectric Patches: A Wave-Based Modelling Approach.

    Science.gov (United States)

    Chronopoulos, Dimitrios; Collet, Manuel; Ichchou, Mohamed

    2015-02-17

    The waves propagating within complex smart structures are hereby computed by employing a wave and finite element method. The structures can be of arbitrary layering and of complex geometric characteristics as long as they exhibit two-dimensional periodicity. The piezoelectric coupling phenomena are considered within the finite element formulation. The mass, stiffness and piezoelectric stiffness matrices of the modelled segment can be extracted using a conventional finite element code. The post-processing of these matrices involves the formulation of an eigenproblem whose solutions provide the phase velocities for each wave propagating within the structure and for any chosen direction of propagation. The model is then modified in order to account for a shunted piezoelectric patch connected to the composite structure. The impact of the energy dissipation induced by the shunted circuit on the total damping loss factor of the composite panel is then computed. The influence of the additional mass and stiffness provided by the attached piezoelectric devices on the wave propagation characteristics of the structure is also investigated.

  16. Damping Enhancement of Composite Panels by Inclusion of Shunted Piezoelectric Patches: A Wave-Based Modelling Approach

    Directory of Open Access Journals (Sweden)

    Dimitrios Chronopoulos

    2015-02-01

    Full Text Available The waves propagating within complex smart structures are hereby computed by employing a wave and finite element method. The structures can be of arbitrary layering and of complex geometric characteristics as long as they exhibit two-dimensional periodicity. The piezoelectric coupling phenomena are considered within the finite element formulation. The mass, stiffness and piezoelectric stiffness matrices of the modelled segment can be extracted using a conventional finite element code. The post-processing of these matrices involves the formulation of an eigenproblem whose solutions provide the phase velocities for each wave propagating within the structure and for any chosen direction of propagation. The model is then modified in order to account for a shunted piezoelectric patch connected to the composite structure. The impact of the energy dissipation induced by the shunted circuit on the total damping loss factor of the composite panel is then computed. The influence of the additional mass and stiffness provided by the attached piezoelectric devices on the wave propagation characteristics of the structure is also investigated.

  17. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    Science.gov (United States)

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the

  18. The CHESS score: a simple tool for early prediction of shunt dependency after aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Jabbarli, R; Bohrer, A-M; Pierscianek, D; Müller, D; Wrede, K H; Dammann, P; El Hindy, N; Özkan, N; Sure, U; Müller, O

    2016-05-01

    Acute hydrocephalus is an early and common complication of aneurysmal subarachnoid hemorrhage (SAH). However, considerably fewer patients develop chronic hydrocephalus requiring shunt placement. Our aim was to develop a risk score for early identification of patients with shunt dependency after SAH. Two hundred and forty-two SAH individuals who were treated in our institution between January 2008 and December 2013 and survived the initial impact were retrospectively analyzed. Clinical parameters within 72 h after the ictus were correlated with shunt dependency. Independent predictors were summarized into a new risk score which was validated in a subsequent SAH cohort treated between January and December 2014. Seventy-five patients (31%) underwent shunt placement. Of 23 evaluated variables, only the following five showed independent associations with shunt dependency and were subsequently used to establish the Chronic Hydrocephalus Ensuing from SAH Score (CHESS, 0-8 points): Hunt and Hess grade ≥IV (1 point), location of the ruptured aneurysm in the posterior circulation (1 point), acute hydrocephalus (4 points), the presence of intraventricular hemorrhage (1 point) and early cerebral infarction on follow-up computed tomography scan (1 point). The CHESS showed strong correlation with shunt dependency (P = 0.0007) and could be successfully validated in both internal SAH cohorts tested. Patients scoring ≥6 CHESS points had significantly higher risk of shunt dependency (P CHESS may become a valuable diagnostic tool for early estimation of shunt dependency after SAH. Further evaluation and external validation will be required in prospective studies. © 2016 EAN.

  19. Cellophane banding for the gradual attenuation of single extrahepatic portosystemic shunts in eleven dogs.

    Science.gov (United States)

    Youmans, K R; Hunt, G B

    1998-08-01

    To evaluate the efficacy and short term effects of a cellophane banding technique for progressive attenuation of canine single extrahepatic portosystemic shunts. A prospective trial of 11 dogs with single congenital extrahepatic shunts. Rectal ammonia tolerance testing and routine biochemical tests were performed preoperatively on all dogs. In seven dogs, preoperative abdominal Doppler ultrasonography was also performed. Exploratory laparotomy revealed a single extrahepatic portocaval shunt in each animal, which was attenuated using a cellophane band with an internal diameter of 2 to 3 mm. The abdomen was closed routinely. Follow-up biochemical analysis and abdominal Doppler ultrasonography or splenoportography were performed postoperatively. The shunt was not amenable to total ligation in 11 dogs, based upon reported criteria. All dogs recovered uneventfully from surgery without evidence of portal hypertension, and showed clinical improvement thereafter. Shunt occlusion was deemed to have occurred in 10 dogs based on resolution of biochemical and/or sonographic abnormalities. One dog continued to have sonographic evidence of portosystemic shunting when evaluated 3 weeks after surgery, despite normal ammonia tolerance, but was lost to subsequent follow-up. Two dogs, in which 3 mm cellophane bands were placed, experienced delayed shunt occlusion. Cellophane banding is simple to perform, and causes progressive attenuation of single extrahepatic shunts in dogs. Further work is needed to determine the maximum diameter of a cellophane band which will produce total attenuation, and the long-term safety and reliability of the treatment.

  20. Multi-resonant electromagnetic shunt in base isolation for vibration damping and energy harvesting

    Science.gov (United States)

    Pei, Yalu; Liu, Yilun; Zuo, Lei

    2018-06-01

    This paper investigates multi-resonant electromagnetic shunts applied to base isolation for dual-function vibration damping and energy harvesting. Two multi-mode shunt circuit configurations, namely parallel and series, are proposed and optimized based on the H2 criteria. The root-mean-square (RMS) value of the relative displacement between the base and the primary structure is minimized. Practically, this will improve the safety of base-isolated buildings subjected the broad bandwidth ground acceleration. Case studies of a base-isolated building are conducted in both the frequency and time domains to investigate the effectiveness of multi-resonant electromagnetic shunts under recorded earthquake signals. It shows that both multi-mode shunt circuits outperform traditional single mode shunt circuits by suppressing the first and the second vibration modes simultaneously. Moreover, for the same stiffness ratio, the parallel shunt circuit is more effective at harvesting energy and suppressing vibration, and can more robustly handle parameter mistuning than the series shunt circuit. Furthermore, this paper discusses experimental validation of the effectiveness of multi-resonant electromagnetic shunts for vibration damping and energy harvesting on a scaled-down base isolation system.

  1. Ventriculoperitoneal shunt for treatment of hydrocephalus in a French bulldog puppy

    Science.gov (United States)

    Giacinti, Jolene A.

    2016-01-01

    A 6.5-week-old bulldog was presented with lethargy, anorexia, and stunted growth. A domed skull, ventrolateral strabismus, hypermetria, and delayed hopping were observed. Congenital hydrocephalus was diagnosed and a ventriculoperitoneal shunt was placed. After surgery, a shunt obstruction occurred but resolved with treatment. The puppy responded well and neurological deficits continued to improve after surgery. PMID:26933271

  2. Medication overuse as a cause of chronic headache in shunted hydrocephalus patients

    DEFF Research Database (Denmark)

    Willer, Lasse; Jensen, R H; Juhler, M

    2010-01-01

    To highlight the group of hydrocephalus patients known to have a long history of shunt revisions and refractory chronic headache. When a shunt in perfect working order has no effect on headache, other causes of headache should be investigated. In this paper, patients with medication overuse...

  3. 21 CFR 882.5550 - Central nervous system fluid shunt and components.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Central nervous system fluid shunt and components... Central nervous system fluid shunt and components. (a) Identification. A central nervous system fluid... central nervous system to an internal delivery site or an external receptacle for the purpose of relieving...

  4. Medication overuse as a cause of chronic headache in shunted hydrocephalus patients

    DEFF Research Database (Denmark)

    Willer, Lasse; Jensen, R H; Juhler, M

    2010-01-01

    To highlight the group of hydrocephalus patients known to have a long history of shunt revisions and refractory chronic headache. When a shunt in perfect working order has no effect on headache, other causes of headache should be investigated. In this paper, patients with medication overuse...... headache are identified and the positive effect of medication withdrawal are described....

  5. l-Arginine Pathway Metabolites Predict Need for Intra-operative Shunt During Carotid Endarterectomy

    DEFF Research Database (Denmark)

    Szabo, P; Lantos, J; Nagy, L

    2016-01-01

    lactate levels were increased during reperfusion (p = .02). The median pre-operative concentration of l-arginine was lower in patients requiring an intra-operative shunt than in patients without need of shunt (median: 30.3 μmol/L [interquartile range 24.4-34.4 μmol/L] vs. 57.6 μmol/L [interquartile range...

  6. H Reactor

    Data.gov (United States)

    Federal Laboratory Consortium — The H Reactor was the first reactor to be built at Hanford after World War II.It became operational in October of 1949, and represented the fourth nuclear reactor on...

  7. Clinical and ultrasonographic criteria for using ventriculoperitoneal shunts in newborns with myelomeningocele

    Directory of Open Access Journals (Sweden)

    Jose Roberto Tude Melo

    2015-09-01

    Full Text Available Objective Hydrocephalus is one of the main complications associated with myelomeningocele (MM. This study aimed to identify clinical and ultrasonographic criteria for using ventriculoperitoneal (VP shunts in this group of patients.Method A retrospective cohort study, based on established protocol for VP shunt implant in hydrocephalic children with MM. Parameters used to guide the indication of VP shunts included measurement of head circumference (HC, evaluation of fontanels, and measurement of lateral ventricular atrium (LVA width by transcranial ultrasonography.Results 43 children were included in the analysis, of which 74% had hydrocephalus and required a VP shunt. These children had LVA width ≥ 15 mm, showed increased HC, or had bulging fontanels.Conclusion VP shunt is required in children with increased HC (≥ 2 standard deviation regarding age group, bulging fontanels, or LVA width of ≥ 15 mm after the closure of MM.

  8. Ventriculoperitoneal shunt-related infections caused by Staphylococcus epidermidis: pathogenesis and implications for treatment.

    LENUS (Irish Health Repository)

    Stevens, Niall T

    2012-12-01

    The insertion of medical devices, such as intraventricular shunts, is often complicated by infection leading to ventriculitis. Frequently, such infections result from colonisation and subsequent biofilm formation on the surfaces of the shunts by Staphylococcus epidermidis. The pathogenesis of neurosurgical shunt-related infection is complex with interactions between the pathogen, the device and the unique local immunological environment of the central nervous system (CNS). An ability to form biofilm, the main virulence determinant of Staphylococcus epidermidis, facilitates protection of the organism from the host defences while still initiating an immunological response. The presence of the blood brain barrier (BBB) and the biofilm itself also complicates treatment, which presents many challenges when managing shunt infections. A greater understanding of the interplay between S. epidermidis and the CNS could potentially improve the diagnosis, treatment and management of such infections. This review describes the pathogenesis, treatment and implications of S. epidermidis ventriculoperitoneal shunt-related infections, concentrating on recent research and the implications for treatment.

  9. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography. Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-02-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt.

  10. Communicating hydrocephalus due to cerebral venous sinus thrombosis treated with ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Rahul T Chakor

    2012-01-01

    Full Text Available Cerebral venous sinus thrombosis (CVT is a rare cerebrovascular disease with variable presentation. CVT rarely causes hydrocephalus. Communicating hydrocephalus due to CVT is extremely rare. We describe a patient of CVT presenting with chronic headache and communicating hydrocephalus. The patient was successfully treated with ventriculoperitoneal (VP shunt. A 40 year old man presented with moderate to severe headache since six months and progressive visual loss since two months. Head Computed tomogram showed mild hydrocephalus without obstruction. Lumbar puncture (LP demonstrated elevated pressure but was otherwise normal. Magnetic resonance venogram showed extensive CVT. Repeated CSF drainage and thecoperitoneal shunt did not relieve the severe headache hence a VP shunt was placed. Post shunt headache subsided with resolution of hydrocephalus. CVT can present as communicating hydrocephalus. Gradual reduction of intra-ventricular pressure by repeated LPs followed by VP shunt can safely treat hydrocephalus due to CVT.

  11. Quantitative determination of peripheral arterio-venous shunts by means of radioactively labelled microspheres

    International Nuclear Information System (INIS)

    Friese, K.H.

    1981-01-01

    In the present work a nuclear method of quantitative measurement of peripheral arterio-venous shunts with a whole-body scanner is standardized. This method, developed at the beginning of the 70s at Tuebingen, stands out in contrast with earlier measuring methods by the application of the theory of quantitative scintiscanning. This means that the scintigram obtained after injection of sup(99m)technetium-labelled human albumin microspheres into an artery before the shunt is corrected for the quantitative shunt calculation by several factors using a computer, to avoid systematic mistakes. For the standardization of the method, 182 scintigrams were taken during model experiments and experiments on animals and human beings. This method, having a deviation of 10% at most, is excellently suited for the quantitative determination of peripheral arterio-venous shunts. Already for a pulmonary activity of 3% a peripheral shunt is proved with 97.5% probability. (orig./MG) [de

  12. A rare cause of pediatric urinary incontinence: Ventriculoperitoneal shunt with bladder perforation

    Directory of Open Access Journals (Sweden)

    Manuel C See IV

    2016-04-01

    Full Text Available We present a case of 2-year-old boy with long term dysuria and intermittent incontinence, and new onset of fever and headache. Significant past medical history includes congenital hydrocephalus with a ventriculoperitoneal shunt placement two years prior to consult. On physical examination, a tubular structure was noted underneath the prepuce suspected to be the distal tip of ventriculoperitoneal shunt, which was confirmed by kidney, ureter and bladder (KUB X-ray and CT scan. Patient was treated with a novel approach of extraperitoneal removal of ventriculoperitoneal shunt distal tip with cystorrhaphy via a low transverse pfannenstiel incision, separate left ventriculostomy tube insertion and complete removal of ventriculoperitoneal shunt from the right ventricle. This report accounts a rare pediatric case with ventriculoperitoneal shunt perforation into a normal bladder successfully treated with mini-open surgery.

  13. Early mediastinal seroma secondary to modified Blalock-Taussig shunts - successful management by percutaneous drainage

    International Nuclear Information System (INIS)

    Connolly, Bairbre L.; Temple, Michael J.; Chait, Peter G.; Restrepo, Ricardo; Adatia, Ian

    2003-01-01

    Large symptomatic mediastinal seroma following modified-BT shunts, traditionally required revisional thoracotomy. We describe percutaneous image-guided pigtail catheter drainage in the successful treatment of early mediastinal seroma secondary to PTFE Blalock-Taussig shunt, avoiding thoracotomy. A retrospective review of all relevant clinical and imaging records in five patients was performed. All five presented with intermittent stridor, respiratory distress and/or episodic desaturation within 6 weeks of their surgery. In four of five infants, percutaneous drainage was effective and reoperation was avoided. In one of five, rather than urgent surgical evacuation and BT shunt revision, we were able to perform an elective stage-II bidirectional Glenn SVC-RA anastamosis in a stable infant. There were no complications. Percutaneous image-guided drainage of mediastinal seroma secondary to PTFE-BT shunt is a safe, minimally invasive, and effective treatment. This may avoid BT shunt revision. (orig.)

  14. Tunable band gaps in acoustic metamaterials with periodic arrays of resonant shunted piezos

    International Nuclear Information System (INIS)

    Chen Sheng-Bing; Wen Ji-Hong; Wang Gang; Wen Xi-Sen

    2013-01-01

    Periodic arrays of resonant shunted piezoelectric patches are employed to control the wave propagation in a two-dimensional (2D) acoustic metamaterial. The performance is characterized by the finite element method. More importantly, we propose an approach to solving the conventional issue of the nonlinear eigenvalue problem, and give a convenient solution to the dispersion properties of 2D metamaterials with periodic arrays of resonant shunts in this article. Based on this modeling method, the dispersion relations of a 2D metamaterial with periodic arrays of resonant shunted piezos are calculated. The results show that the internal resonances of the shunting system split the dispersion curves, thereby forming a locally resonant band gap. However, unlike the conventional locally resonant gap, the vibrations in this locally resonant gap are unable to be completely localized in oscillators consisting of shunting inductors and piezo-patches

  15. Symptomatic spinal cord deformity secondary to a redundant intramedullary shunt catheter

    International Nuclear Information System (INIS)

    Quencer, R.M.; Montalvo Morse, B.M.; Green, B.A.; Eismont, F.J.

    1985-01-01

    Right arm pain, motor and sensory loss in the right arm and right facial numbness recurred in a 27 year old quadraplegic shortly after a posttraumatic spinal cord cyst (PTSCC) was shunted via a catheter into the adjacent subarachnoid space. Although shunt malfunction was clinically suspected, metrizamide computed tomography (MCT) suggested that redundancy of the catheter had caused deformity of the spinal cord. This hypothesis was confirmed at surgery when intraoperative spinal sonography (IOSS) showed that the spinal cord deformity at C 1 -C 2 disappeared when the catheter was withdrawn. This case shows that new or recurrent spinal cord symptoms may be due to a mechanical deformity of the cord rather than shunt malfunction, that restricting the length of the shunt catheter which is used to decompress PTSCCs is important, and that IOSS is an indispensible tool for visualizing the changes in spinal cord morphology during shunting procedures. (orig.)

  16. Intrahepatic portal-hepatic venous shunt diagnosed by ultrasonography and computed tomography

    International Nuclear Information System (INIS)

    Shinagawa, Takashi; Iino, Yasuo; Ukaji, Haruyasu; Ishizuka, Masaharu

    1986-01-01

    Two cases of intrahepatic portal-hepatic venous shunt found by ultrasonography and computed tomography are reported. The first case came to the hospital because of hematuria. A large shunt between the portal vein and the hepatic vein was demonstrated by ultrasonography done for screening, and confirmed by percutaneous transhepatic portography (PTP). The second case was admitted because of cholelithiasis. Computed tomography with contrast enhancement revealed a dilated portal vein in the upper portion of the right lobe. It was subsequently shown by PTP to be a portal-hepatic venous shunt. Portal vein pressure and histological finding of the liver were normal in both cases. The etiology of the shunt was thought to be congenital in these cases for lack of liver disease, portal hypertension and history of trauma. Both cases had no history of hepatic encephalopathy and did not show any symptom attributable to the shunt. (author)

  17. Making Connections

    Science.gov (United States)

    Pien, Cheng Lu; Dongsheng, Zhao

    2011-01-01

    Effective teaching includes enabling learners to make connections within mathematics. It is easy to accord with this statement, but how often is it a reality in the mathematics classroom? This article describes an approach in "connecting equivalent" fractions and whole number operations. The authors illustrate how a teacher can combine a common…

  18. Emergency reactor cooling device

    International Nuclear Information System (INIS)

    Arakawa, Ken.

    1993-01-01

    An emergency nuclear reactor cooling device comprises a water reservoir, emergency core cooling water pipelines having one end connected to a water feeding sparger, fire extinguishing facility pipelines, cooling water pressurizing pumps, a diesel driving machine for driving the pumps and a battery. In a water reservoir, cooling water is stored by an amount required for cooling the reactor upon emergency and for fire extinguishing, and fire extinguishing facility pipelines connecting the water reservoir and the fire extinguishing facility are in communication with the emergency core cooling water pipelines connected to the water feeding sparger by system connection pipelines. Pumps are operated by a diesel power generator to introduce cooling water from the reservoir to the emergency core cooling water pipelines. Then, even in a case where AC electric power source is entirely lost and the emergency core cooling system can not be used, the diesel driving machine is operated using an exclusive battery, thereby enabling to inject cooling water from the water reservoir to a reactor pressure vessel and a reactor container by the diesel drive pump. (N.H.)

  19. Management of Ventriculoperitoneal Shunt Infections in Adults: Analysis of Risk Factors Associated With Treatment Failure.

    Science.gov (United States)

    Pelegrín, Iván; Lora-Tamayo, Jaime; Gómez-Junyent, Joan; Sabé, Nuria; García-Somoza, Dolors; Gabarrós, Andreu; Ariza, Javier; Viladrich, Pedro Fernández; Cabellos, Carmen

    2017-04-15

    Little is known regarding the optimal treatment of ventriculoperitoneal (VP) shunt infections in adults. Our aim was to assess the efficacy of treatment strategies and to identify factors that predict failure. Retrospective, observational study of patients aged ≥12 years with VP shunt infections (1980 -2014). Therapeutic approaches were classified under 4 headings: only antibiotics (OA), one-stage shunt replacement (OSSR), two-stage shunt replacement (TSSR), and shunt removal without replacement (SR). The primary endpoint was failure of the treatment strategy, defined as the absence of definite cerebrospinal fluid (CSF) sterilization or related mortality. The parameters that predicted failure were analyzed using logistic regression. Of 108 episodes (51% male, median age 50 years), 86 were analyzed. Intravenous antibiotics were administered for a median of 19 days. Eighty episodes were treated using strategies that combined antibiotic and surgical treatment (37 TSSR, 24 SR, 19 OSSR) and 6 with OA. Failure occurred in 30% of episodes, mostly due to lack of CSF sterilization in OSSR and OA groups. Twelve percent died of related causes and 10% presented superinfection of the CSF temporary drainage/externalized peritoneal catheter. TSSR was the most effective strategy when VP shunt replacement was attempted. The only independent risk factor that predicted failure was retention of the VP shunt, regardless of the strategy. This is the largest series of VP shunt infections in adults reported to date. VP shunt removal, particularly TSSR when the patient is shunt dependent, remains the optimal choice of treatment and does not increase morbidity. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  20. Shunt-dependent hydrocephalus: management style among members of the American Society of Pediatric Neurosurgeons.

    Science.gov (United States)

    Kraemer, Mark R; Sandoval-Garcia, Carolina; Bragg, Taryn; Iskandar, Bermans J

    2017-09-01

    OBJECTIVE The authors conducted a survey to evaluate differences in the understanding and management of shunt-dependent hydrocephalus among members of the American Society of Pediatric Neurosurgeons (ASPN). METHODS Surveys were sent to all 204 active ASPN members in September 2014. One hundred thirty responses were received, representing a 64% response rate. Respondents were asked 13 multiple-choice and free-response questions regarding 4 fundamental problems encountered in shunted-hydrocephalus management: shunt malfunction, chronic cerebrospinal fluid (CSF) overdrainage, chronic headaches, and slit ventricle syndrome (SVS). RESULTS Respondents agreed that shunt malfunction occurs most often as the result of ventricular catheter obstruction. Despite contrary evidence in the literature, most respondents (66%) also believed that choroid plexus is the tissue most often found in obstructed proximal catheters. However, free-text responses revealed that the respondents' understanding of the underlying pathophysiology of shunt obstruction was highly variable and included growth, migration, or adherence of choroid plexus, CSF debris, catheter position, inflammatory processes, and CSF overdrainage. Most respondents considered chronic CSF overdrainage to be a rare complication of shunting in their practice and reported wide variation in treatment protocols. Moreover, despite a lack of evidence in the literature, most respondents attributed chronic headaches in shunt patients to medical reasons (for example, migraines, tension). Accordingly, most respondents managed headaches with reassurance and/or referral to pain clinics. Lastly, there were variable opinions on the etiology of slit ventricle syndrome (SVS), which included early shunting, chronic overdrainage, and/or loss of brain compliance. Beyond shunt revision, respondents reported divergent SVS treatment preferences. CONCLUSIONS The survey shows that there is wide variability in the understanding and management of

  1. Transjugular Intrahepatic Portosystemic Shunts in Children with Biliary Atresia

    International Nuclear Information System (INIS)

    Huppert, Peter E.; Goffette, Pierre; Astfalk, Wolfgang; Sokal, Emil M.; Brambs, Hans-Juergen; Schott, Ullrich; Duda, Stephan H.; Schweizer, Paul; Claussen, Claus D.

    2002-01-01

    Purpose: We retrospectively evaluated the technical and long-term clinical results of transjugularintrahepatic portosystemic shunts (TIPS) in children with portal hypertension and biliary atresia (BA). Methods: Nine children with BA and recurrent bleeding from esophagogastric and/or intestinal varices were treated by TIPS at the age of 34-156 months and followed-up in two centers. Different types of stents were used. Results: Shunt insertion succeeded in all patients, but in two a second procedure was necessary. Seven procedures lasted more than 3 hr, mainly due to difficult portal vein puncture.Variceal bleeding ceased in all patients; however, 16 reinterventions were performed in eight patients for clinical reasons (n =11) and sonographically suspected restenosis (n =5). Four patients underwent successful liver transplantation 4-51 months after TIPS and five are in good clinical conditions 64-75 months after TIPS. Conclusions: TIPS in children with BA is technically difficult, mainly due to periportal fibrosis and small portal veins. Frequency of reinterventions seems to be higher compared with adults

  2. Effect of amusement park rides on programmable shunt valve settings.

    Science.gov (United States)

    Strahle, Jennifer; Collins, Kelly; Stetler, William R; Smith, Brandon W; Garton, Thomas; Garton, Catherine; Garton, Hugh J L; Maher, Cormac O

    2013-01-01

    Magnetically programmable shunt valves are susceptible to environmental factors including magnetic fields and accelerative forces. It is unknown if rollercoasters with or without magnetic brakes or linear induction motors (LIMs) are capable of altering the setting of a programmable shunt valve. Two different valve types (type A, n = 10; type B, n = 9) were tested at varying resistance settings in 2 trials on 6 different amusement park rides including 2 rides with LIMs, 2 rides with magnetic brakes, and 2 rides without magnetic technology. The performance level of valve type A and the setting of valve type B changed on rollercoasters with magnets (A = 2.5% [2/80]; B = 5.6% [4/72]) and without magnets (A = 7.5% [3/40]; B = 2.8% [1/36]). Neither valve setting changed when exposed to a Ferris wheel or during ambulation throughout the park. Magnetically programmable valves are susceptible to changes in pressure settings when exposed to amusement park rides with elevated vertical gravitational forces, irrespective of the presence of LIMs or magnetic brakes. © 2013 S. Karger AG, Basel.

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS): Current Status and Future Possibilities

    International Nuclear Information System (INIS)

    Bilbao, Jose Ignacio; Quiroga, Jorge; Herrero, Jose Ignacio; Benito, Alberto

    2002-01-01

    Since the insertion of the first TIPS in 1989 much has been learned about this therapeutic procedure. It has an established role for the treatment of some complications of portal hypertension: prevention of recurrent variceal bleeding and rescue of patients with acute uncontrollable variceal bleeding. In addition TIPS is useful for Budd-Chiari syndrome, refractory ascites and hepatorenal syndrome, although its specific role in these indications remains to be definitively established. However, the decrease in sinusoidal blood flow induced by TIPS can lead to the patient developing hepatic encephalopathy and liver failure in some cases. Therefore, TIPS should be used with caution in patients with very poor liver function. From a technical point of view, successful placement of TIPS is achieved in more than 98% of cases by experienced groups. At present, evaluation of TIPS dysfunction based on morphology probably leads to an overdiagnosis of this complication since most of these cases are not associated with clinical manifestations (recurrent bleeding or refractory ascites). The major disadvantage of TIPS remains its poor long-term patency requiring a mandatory surveillance program. The indicator for shunt function/malfunction should be the portosystemic pressure gradient, which is best assessed by intravascular measurements. Shunt obstructions may be prevented or reduced by the use of stent-grafts in the future

  4. Reactor control device

    International Nuclear Information System (INIS)

    Kameda, Akiyuki.

    1979-01-01

    Purpose: To enable three types of controls, that is, level control, scram control and excess reactivity control required for a reactor by a same mechanism by feeding neutron absorber liquid and pressure control gas to several blind pipes provided in the reactor core. Constitution: A plurality of blind pipes are disposed spaced apart in a reactor core and connected by way of injection pipes to a neutron absorber liquid tank. A pressure regulator is connected to the blind pipes, to which pressure control gas is supplied. The neutron absorber liquid used herein consists of sodium, potassium or their alloy, or mercury as a basic substance incorporated with one or more selected from boron, tantalum, rhenium, europium or their compounds. The level control, scram control and excess reactivity control can be attained by moderating the pressure changes in the pressure control gas or by regulating the fluctuation in the liquid level. (Horiughi, T.)

  5. Meltdown reactor core cooling facility

    International Nuclear Information System (INIS)

    Matsuoka, Tsuyoshi.

    1992-01-01

    The meltdown reactor core cooling facility comprises a meltdown reactor core cooling tank, a cooling water storage tank situates at a position higher than the meltdown reactor core cooling tank, an upper pipeline connecting the upper portions of the both of the tanks and a lower pipeline connecting the lower portions of them. Upon occurrence of reactor core meltdown, a high temperature meltdown reactor core is dropped on the cooling tank to partially melt the tank and form a hole, from which cooling water is flown out. Since the water source of the cooling water is the cooling water storage tank, a great amount of cooling water is further dropped and supplied and the reactor core is submerged and cooled by natural convection for a long period of time. Further, when the lump of the meltdown reactor core is small and the perforated hole of the meltdown reactor cooling tank is small, cooling water is boiled by the high temperature lump intruding into the meltdown reactor core cooling tank and blown out from the upper pipeline to the cooling water storage tank to supply cooling water from the lower pipeline to the meltdown reactor core cooling tank. Since it is constituted only with simple static facilities, the facility can be simplified to attain improvement of reliability. (N.H.)

  6. Agreement of 10 September 1991 between the International Atomic Energy Agency and the Government of the Islamic Republic of Pakistan for the application of safeguards in connection with the supply of a miniature neutron source reactor from the People's Republic of China

    International Nuclear Information System (INIS)

    1991-10-01

    The document reproduces the text of the Agreement of 10 September 1991, between the Government of the Islamic Republic of Pakistan and the International Atomic Energy Agency for the application of safeguards in connection with the supply of a miniature neutron source reactor from the People's Republic of China. The Agreement was approved by the Agency's Board of Governors on 20 February 1990 and entered into force upon signature on 10 September 1991

  7. About Connections

    Directory of Open Access Journals (Sweden)

    Kathleen S Rockland

    2015-05-01

    Full Text Available Despite the attention attracted by connectomics, one can lose sight of the very real questions concerning What are connections? In the neuroimaging community, structural connectivity is ground truth and underlying constraint on functional or effective connectivity. It is referenced to underlying anatomy; but, as increasingly remarked, there is a large gap between the wealth of human brain mapping and the relatively scant data on actual anatomical connectivity. Moreover, connections have typically been discussed as pairwise, point x projecting to point y (or: to points y and z, or more recently, in graph theoretical terms, as nodes or regions and the interconnecting edges. This is a convenient shorthand, but tends not to capture the richness and nuance of basic anatomical properties as identified in the classic tradition of tracer studies. The present short review accordingly revisits connectional weights, heterogeneity, reciprocity, topography, and hierarchical organization, drawing on concrete examples. The emphasis is on presynaptic long-distance connections, motivated by the intention to probe current assumptions and promote discussions about further progress and synthesis.

  8. Gas cooled reactors

    International Nuclear Information System (INIS)

    Kojima, Masayuki.

    1985-01-01

    Purpose: To enable direct cooling of reactor cores thereby improving the cooling efficiency upon accidents. Constitution: A plurality sets of heat exchange pipe groups are disposed around the reactor core, which are connected by way of communication pipes with a feedwater recycling device comprising gas/liquid separation device, recycling pump, feedwater pump and emergency water tank. Upon occurrence of loss of primary coolants accidents, the heat exchange pipe groups directly absorb the heat from the reactor core through radiation and convection. Although the water in the heat exchange pipe groups are boiled to evaporate if the forcive circulation is interrupted by the loss of electric power source, water in the emergency tank is supplied due to the head to the heat exchange pipe groups to continue the cooling. Furthermore, since the heat exchange pipe groups surround the entire circumference of the reactor core, cooling is carried out uniformly without resulting deformation or stresses due to the thermal imbalance. (Sekiya, K.)

  9. Method of reactor fueling

    International Nuclear Information System (INIS)

    Saito, Toshiro.

    1983-01-01

    Purpose: To decrease the cost and shorten the working time by saving fueling neutron detectors and their components. Method: Incore drive tubes for the neutron source range monitor (SRM) and intermediate range monitor (IRM) are disposed respectively within in a reactor core and a SRM detector assembly is inserted to the IRM incore drive tube which is most nearest to the neutron source upon reactor fueling. The reactor core reactivity is monitored by the SRM detector assembly. The SRM detector asesembly inserted into the IRM drive tube is extracted at the time of charging fuels up to the frame connecting the SRM and, thereafter, IRM detection assembly is inserted into the IRM drive tube and the SRM detector assembly is inserted into the SRM drive tube respectively for monitoring the reactor core. (Sekiya, K.)

  10. Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Roesch-Uchida transjugular liver access set; Evaluation by CT and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Motoichiro; Okawada, Taketoshi; Kato, Ryoichi; Mochizuki, Takao; Ohkawa, Yoshihisa; Kaneko, Masao [Hamamatsu University School of Medicine, Shizuoka (Japan); Ke, Xu; Hanguo, Zhang; Fangxian, He

    1992-12-01

    Appropriateness of the Roesch-Uchida transjugular liver access set designed for transjugular intrahepatic portosystemic stent shunt (TIPSS) procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe. (author).

  11. Treatment of extrahepatic portal hypertension following a whipple procedure with a Rex shunt: report of a case.

    Science.gov (United States)

    Reichman, Trevor W; Anthony, Tiffany; Testa, Giuliano

    2011-02-01

    The Rex shunt is a mesenteric vein to left portal vein decompressive shunt used for the treatment of portal vein thrombosis and portal hypertension. Its use has been reported primarily in the pediatric population where portal vein thrombosis occurs with some frequency. The shunt is thought to represent a more physiologic shunt, since it restores hepatopedal blood flow through the liver. This report describes the use of this shunt in an adult who had frequent gastrointestinal bleeding secondary to extrahepatic portal vein thrombosis, which occurred as a complication after a pancreaticoduodenectomy.

  12. Microelectromechanical filter formed from parallel-connected lattice networks of contour-mode resonators

    Science.gov (United States)

    Wojciechowski, Kenneth E; Olsson, III, Roy H; Ziaei-Moayyed, Maryam

    2013-07-30

    A microelectromechanical (MEM) filter is disclosed which has a plurality of lattice networks formed on a substrate and electrically connected together in parallel. Each lattice network has a series resonant frequency and a shunt resonant frequency provided by one or more contour-mode resonators in the lattice network. Different types of contour-mode resonators including single input, single output resonators, differential resonators, balun resonators, and ring resonators can be used in MEM filter. The MEM filter can have a center frequency in the range of 10 MHz-10 GHz, with a filter bandwidth of up to about 1% when all of the lattice networks have the same series resonant frequency and the same shunt resonant frequency. The filter bandwidth can be increased up to about 5% by using unique series and shunt resonant frequencies for the lattice networks.

  13. Internet Connectivity

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Internet Connectivity. BSNL, SIFY, HCL in Guwahati; only BSNL elsewhere in NE (local player in Shillong). Service poor; All vendors lease BW from BSNL.

  14. Mathematics Connection

    African Journals Online (AJOL)

    MATHEMATICS CONNECTION aims at providing a forum topromote the development of Mathematics Education in Ghana. Articles that seekto enhance the teaching and/or learning of mathematics at all levels of theeducational system are welcome.

  15. HR Connect

    Data.gov (United States)

    US Agency for International Development — HR Connect is the USAID HR personnel system which allows HR professionals to process HR actions related to employee's personal and position information. This system...

  16. An in vitro lung model to assess true shunt fraction by multiple inert gas elimination.

    Directory of Open Access Journals (Sweden)

    Balamurugan Varadarajan

    Full Text Available The Multiple Inert Gas Elimination Technique, based on Micropore Membrane Inlet Mass Spectrometry, (MMIMS-MIGET has been designed as a rapid and direct method to assess the full range of ventilation-to-perfusion (V/Q ratios. MMIMS-MIGET distributions have not been assessed in an experimental setup with predefined V/Q-distributions. We aimed (I to construct a novel in vitro lung model (IVLM for the simulation of predefined V/Q distributions with five gas exchange compartments and (II to correlate shunt fractions derived from MMIMS-MIGET with preset reference shunt values of the IVLM. Five hollow-fiber membrane oxygenators switched in parallel within a closed extracorporeal oxygenation circuit were ventilated with sweep gas (V and perfused with human red cell suspension or saline (Q. Inert gas solution was infused into the perfusion circuit of the gas exchange assembly. Sweep gas flow (V was kept constant and reference shunt fractions (IVLM-S were established by bypassing one or more oxygenators with perfusate flow (Q. The derived shunt fractions (MM-S were determined using MIGET by MMIMS from the retention data. Shunt derived by MMIMS-MIGET correlated well with preset reference shunt fractions. The in vitro lung model is a convenient system for the setup of predefined true shunt fractions in validation of MMIMS-MIGET.

  17. Frontal and occipital horn ratio is associated with multifocal intraparenchymal hemorrhages in neonatal shunted hydrocephalus.

    Science.gov (United States)

    Oushy, Soliman; Parker, Jonathon J; Campbell, Kristen; Palmer, Claire; Wilkinson, Corbett; Stence, Nicholas V; Handler, Michael H; Mirsky, David M

    2017-11-01

    OBJECTIVE Placement of a cerebrospinal fluid diversion device (i.e., shunt) is a routine pediatric neurosurgical procedure, often performed in the first weeks of life for treatment of congenital hydrocephalus. In the postoperative period, shunt placement may be complicated by subdural, catheter tract, parenchymal, and intraventricular hemorrhages. The authors observed a subset of infants and neonates who developed multifocal intraparenchymal hemorrhages (MIPH) following shunt placement and sought to determine any predisposing perioperative variables. METHODS A retrospective review of the electronic medical record at a tertiary-care children's hospital was performed for the period 1998-2015. Inclusion criteria consisted of shunt placement, age hydrocephalus. Markers of severity of ventriculomegaly (FOR) and ventricular response to CSF diversion (∆FOR) were significantly associated with occurrence of MIPH. Choice of shunt and etiology of hydrocephalus were also significantly associated with MIPH. After adjusting for corrected age, etiology of hydrocephalus, and shunt setting, the authors found that ∆FOR after shunting was still associated with MIPH. A prospective study of MIPH prevention strategies and assessment of possible implications for patient outcomes is needed.

  18. Controversies: Optic nerve sheath fenestration versus shunt placement for the treatment of idiopathic intracranial hypertension

    Directory of Open Access Journals (Sweden)

    Arielle Spitze

    2014-01-01

    Full Text Available Background: Idiopathic intracranial hypertension (IIH has been increasing in prevalence in the past decade, following the obesity epidemic. When medical treatment fails, surgical treatment options must be considered. However, controversy remains as to which surgical procedure is the preferred surgical option - optic nerve sheath fenestration (ONSF or cerebrospinal fluid (CSF shunting - for the long-term treatment of this syndrome. Purpose: To provide a clinical update of the pros and cons of ONSF versus shunt placement for the treatment of IIH. Design: This was a retrospective review of the current literature in the English language indexed in PubMed. Methods: The authors conducted a PubMed search using the following terms: Idiopathic IIH, pseudotumor cerebri, ONSF, CSF shunts, vetriculo-peritoneal shunting, and lumbo-peritoneal shunting. The authors included pertinent and significant original articles, review articles, and case reports, which revealed the new aspects and updates in these topics. Results: The treatment of IIH remains controversial and lacks randomized controlled clinical trial data. Treatment of IIH rests with the determination of the severity of IIH-related visual loss and headache. Conclusion: The decision for ONSF versus shunting is somewhat institution and surgeon dependent. ONSF is preferred for patients with visual symptoms whereas shunting is reserved for patients with headache. There are positive and negative aspects of both procedures, and a prospective, randomized, controlled trial is needed (currently underway. This article will hopefully be helpful in allowing the reader to make a more informed decision until that time.

  19. A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study.

    Science.gov (United States)

    Tubbs, R Shane; Goodrich, Dylan; Tubbs, Isaiah; Loukas, Marios; Cohen-Gadol, Aaron A

    2014-12-01

    Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications. On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions. Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150-200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen. Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

  20. Numerical and experimental studies of stack shunt current for vanadium redox flow battery

    International Nuclear Information System (INIS)

    Yin, Cong; Guo, Shaoyun; Fang, Honglin; Liu, Jiayi; Li, Yang; Tang, Hao

    2015-01-01

    Highlights: • A coupled three-dimensional model of VRB cell stack is developed. • Shunt current of the stack is studied with the model and experiment. • Increased electrolyte resistance in channel and manifold lowers the shunt current. • Shunt current loss increases with stack cell number nonlinearly. - Abstract: The stack shunt current of VRB (vanadium redox flow battery) was investigated with experiments and 3D (three-dimensional) simulations. In the proposed model, cell voltages and electrolyte conductivities were calculated based on electrochemical reaction distributions and SOC (state of charge) values, respectively, while coulombic loss was estimated according to shunt current and vanadium ionic crossover through membrane. Shunt current distributions and coulombic efficiency are analyzed in terms of electrolyte conductivities and stack cell numbers. The distributions of cell voltages and shunt currents calculated with proposed model are validated with single cell and short stack tests. The model can be used to optimize VRB stack manifold and channel designs to improve VRB system efficiency

  1. Correlation of experimental rCBF determinations in goats with flow measurements from a Doppler-modified carotid artery shunt

    International Nuclear Information System (INIS)

    Loftus, C.M.; Silvidi, J.A.; Becker, J.A.; Miller, B.V.; Bernstein, D.D.

    1989-01-01

    A carotid artery shunt system has been developed that continuously monitors blood flow rates by embedding a Doppler crystal in the shunt wall. The crystal ranges through a liquid lens that enables it to be placed without violation of the shunt lumen. Because the crystal is at a fixed angle (45 degrees) to the axis of blood flow and the diameter of the lumen remains constant, a linear relationship exists between flow rates and the Doppler velocity signal. This shunt system was previously tested in vitro using a pulsatile pump and was found to be accurate to within 4.7% of the actual flow rate. In the present study, animal (goat) experiments were performed consisting of simultaneous carotid shunt flow and bilateral rCBF measurements by the radiolabeled microsphere technique to determine in vivo the accuracy of this Doppler modified shunt and to ascertain the ability of shunt flow to increase in the face of acute contralateral carotid occlusion. Data from five animals show that in vivo shunt flow can be recorded to within 13% of control rCBF and that shunt flow increases nearly 50% under conditions of distal demand (contralateral carotid occlusion). This device may prove useful in laboratory studies of carotid shunt dynamics and in clinical practice to quickly detect correctable shunt flow abnormalities

  2. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  3. Continuous monitoring of intracranial pressure after endoscopic third ventriculostomy in the management of CSF shunt failure.

    Science.gov (United States)

    Elgamal, E A

    2010-04-01

    The effectiveness of continuous intracranial pressure (ICP) monitoring in the adaptation period, after endoscopic third ventriculostomy (ETV), and removal of the failed shunt in the management of CSF shunt failure is assessed. Nine patients with active hydrocephalus presenting with CSF shunt obstruction or infection were managed by ETV, removal of the shunt and insertion of an external ventricular drain (EVD) containing an ICP sensor for the purpose of postoperative monitoring of the ICP, and intermittent drainage of CSF. Patient ages ranged from 8 months to 24 years, and six of them were females. Hydrocephalus was obstructive in seven patients, and multiloculated in two. Six patients had an ventriculoperitoneal shunt (VPS), one with a bilateral VPS, one patient had a ventriculoatrial shunt, and one had a VPS and cystoperitoneal shunt (CPS). Shunt failure was caused by obstruction in six patients and infection in three. The post-operative ICP monitoring period ranged from 1-7 days. Intracranial hypertension was persistent in the first day after ETV in 3 patients, and up to 110 mL of CSF were drained to improve its symptoms. ETV was successful in six patients and 3 had permanent VPS. Post-operative continuous ICP monitoring and EVD insertion were very useful in the treatment of CSF shunt failure with ETV. This procedure allowed intermittent CSF drainage, relieving symptoms of elevated ICP, and provided accurate assessment of the success of the ETV and patency of the stoma in the early postoperative days by CT ventriculography and can also be used to install antibiotics in cases of infection.

  4. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    International Nuclear Information System (INIS)

    Bruckheimer, Elchanan; Dagan, Tamir; Atar, Eli; Schwartz, Michael; Kachko, Ludmila; Superina, Riccardo; Amir, Gabriel; Shapiro, Rivka; Birk, Einat

    2013-01-01

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by ∼50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5–13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2–8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 ± 11.3 to 10.8 ± 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 ± 0.5 to 4.0 ± 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 ± 53.6 to 65.7 ± 9.6 μmol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia

  5. Impaired arm development after Blalock-Taussig shunts in adults with repaired tetralogy of Fallot.

    Science.gov (United States)

    Le Gloan, Laurianne; Marcotte, François; Leduc, Hugues; Mercier, Lise-Andrée; Dore, Annie; Mongeon, François-Pierre; Ibrahim, Reda; Miro, Joaquim; Asgar, Anita; Poirier, Nancy; Khairy, Paul

    2013-09-30

    Many adults with repaired tetralogy of Fallot have had prior Blalock-Taussig shunts. These shunts may theoretically hinder growth and development of the ipsilateral arm. We prospectively enrolled consecutive patients with tetralogy of Fallot in a cross-sectional study to measure arm length and assess handgrip strength. Bilateral handgrip strength was quantified by a dynamometer in a standing position after instructing patients to clench each hand tightly in succession. The maximum force achieved, in kilograms, was measured. A total of 80 consecutive adults with tetralogy of Fallot, aged 36.0 ± 12.5 years, 49% female, were prospectively enrolled. Thirty-eight (47.5%) patients had prior Blalock-Taussig shunts at a median age of 1.0 year. Twenty-one (55.3%) were left-sided and 23 (60.5%) were classic shunts. All but six patients with right-sided shunts and one without a prior shunt were right-handed. The shunts were present for a median of 4.0 years prior to takedown during corrective surgery. The arm ipsilateral to the shunt was significantly shorter than the contralateral arm (71.5 ± 6.1 versus 73.6 ± 5.6 cm, Ptetralogy of Fallot, Blalock-Taussig shunts may impair normal development of the ipsilateral arm with repercussions in adulthood that include shorter limb length and reduced handgrip strength. These changes are most pronounced in patients with classic end-to-side anastomoses. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Our initial experience with ventriculo-epiplooic shunt in treatment of hydrocephalus in two centers.

    Science.gov (United States)

    Grigorean, Valentin Titus; Sandu, Aurelia Mihaela; Popescu, Mihai; Florian, Ioan Stefan; Lupascu, Cristian Dumitru; Ursulescu, Corina Lupascu

    Hydrocephalus represents impairment in cerebrospinal fluid (CSF) dynamics. If the treatment of hydrocephalus is considered difficult, the repeated revisions of ventriculo-peritoneal (VP) shunts are even more challenging. The aim of this article is to evaluate the efficiency of ventriculo-epiplooic (VEp) shunt as a feasible alternative in hydrocephalic patients. A technical modification regarding the insertion of peritoneal catheter was imagined: midline laparotomy 8-10cm long was performed in order to open the peritoneal cavity; the great omentum was dissected between its two layers; we placed the distal end of the catheter between the two epiplooic layers; a fenestration of 4cm in diameter into the visceral layer was also performed. A retrospective study of medical records of 15 consecutive patients with hydrocephalus treated with VEp shunt is also presented. Between 2008 and 2014 we performed VEp shunt in 15 patients: 5 with congenital hydrocephalus, 8 with secondary hydrocephalus and 2 with normal pressure hydrocephalus. There were 7 men and 8 women. VEp shunt was performed in 13 patients with multiple distal shunt failures and in 2 patients, with history of abdominal surgery, as de novo extracranial drainage procedure. The outcome was favorable in all cases, with no significant postoperative complications. VEp shunt is a new, safe and efficient surgical technique for the treatment of hydrocephalus. VEp shunt is indicated in patients with history of recurrent distal shunt failures, and in patients with history of open abdominal surgery and high risk for developing abdominal complications. Copyright © 2017 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  7. Gravitational shunt units may cause under-drainage in bedridden patients.

    Science.gov (United States)

    Kaestner, S; Kruschat, T; Nitzsche, N; Deinsberger, W

    2009-03-01

    Implantation of a shunt in a hydrocephalic patient still carries a risk of complications such as over-drainage and under-drainage. Gravitational shunt units are especially designed to minimize the problem of over-drainage. Nevertheless, these valves carry a risk of under-drainage. The best choice of valve for a patient is still challenging. The purpose of this survey was to identify in which patients a gravitational shunt valve is liable to lead to under-drainage. Patients with hydrocephalus entered prospectively into a data base were reviewed retrospectively. The patients were treated between January 2006 to the end of Feb 2007 and those experiencing under- or over-drainage were identified. Thirty-five ventriculo-peritoneal shunt systems were implanted in adult patients. The cause of the hydrocephalus was: normal pressure hydrocephalus in 18 patients, post-haemorrhagic following subarachnoid or intracerebral haemorrhage in 11, associated with a tumour in four and followed a head injury in two patients. Three different valves were used: an adjustable shunt valve with gravitational unit (Pro-GAV 0-20/25 in 21 patients), a gravitational shunt valve with fixed opening pressure (GAV 5/30 in nine patients) and an adjustable differential valve (Hakim medos in five patients). Four patients developed severe, valve-related under-drainage. Each had received a gravitational shunt valve and all were bedridden. In two of these patients it was necessary to change the valve. One patient who had received a differential valve, after regaining mobility developed severe over-drainage with bilateral subdural haematomas. Over-drainage was not seen in long-term bedridden patients with a differential shunt valve. If a bedridden patient with a gravitational shunt valve system lies with a slightly elevated head, this leads to activation of the gravitational unit and this may cause under drainage. As a result, we advise not using an anti-siphon devices in a patient who is bedridden for a

  8. Renal Arteriovenous Shunts: Clinical Features, Imaging Appearance, and Transcatheter Embolization Based on Angioarchitecture.

    Science.gov (United States)

    Maruno, Miyuki; Kiyosue, Hiro; Tanoue, Shuichi; Hongo, Norio; Matsumoto, Shunro; Mori, Hiromu; Sagara, Yoshiko; Kashiwagi, Junji

    2016-01-01

    Renal arteriovenous (AV) shunt, a rare pathologic condition, is divided into two categories, traumatic and nontraumatic, and can cause massive hematuria, retroperitoneal hemorrhage, pain, and high-output heart failure. Although transcatheter embolization is a less-invasive and effective treatment option, it has a potential risk of complications, including renal infarction and pulmonary embolism, and a potential risk of recanalization. The successful embolization of renal AV shunt requires a complete occlusion of the shunted vessel while preventing the migration of embolic materials and preserving normal renal arterial branches, which depends on the selection of adequate techniques and embolic materials for individual cases, based on the etiology and imaging angioarchitecture of the renal AV shunts. A classification of AV malformations in the extremities and body trunk could precisely correspond with the angioarchitecture of the nontraumatic renal AV shunts. The selection of techniques and choice of adequate embolic materials such as coils, vascular plugs, and liquid materials are determined on the basis of cause (eg, traumatic vs nontraumatic), the classification, and some other aspects of the angioarchitecture of renal AV shunts, including the flow and size of the fistulas, multiplicity of the feeders, and endovascular accessibility to the target lesions. Computed tomographic angiography and selective digital subtraction angiography can provide precise information about the angioarchitecture of renal AV shunts before treatment. Color Doppler ultrasonography and time-resolved three-dimensional contrast-enhanced magnetic resonance angiography represent useful tools for screening and follow-up examinations of renal AV shunts after embolization. In this article, the classifications, imaging features, and an endovascular treatment strategy based on the angioarchitecture of renal AV shunts are described. (©)RSNA, 2016.

  9. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    Energy Technology Data Exchange (ETDEWEB)

    Bruckheimer, Elchanan, E-mail: elchananb@bezeqint.net; Dagan, Tamir [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Atar, Eli; Schwartz, Michael [Schneider Children' s Medical Center Israel, Section of Radiology (Israel); Kachko, Ludmila [Schneider Children' s Medical Center Israel, Section of Anesthesiology (Israel); Superina, Riccardo; Amir, Gabriel [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Shapiro, Rivka [Schneider Children' s Medical Center Israel, Section of Gastroenterology (Israel); Birk, Einat [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel)

    2013-12-15

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

  10. Percutaneous Transjugular Direct Porto-caval Shunt in Patients with Budd-Chiari Syndrome

    International Nuclear Information System (INIS)

    Quateen, A.; Pech, M.; Berg, T.; Bergk, A.; Podrabsky, P.; Felix, R.; Ricke, J.

    2006-01-01

    The purpose of the study was to evaluate the feasibility and effectiveness of direct porto-caval shunts in patients with Budd-Chiari syndrome (BCS) in whom there is no access to the hepatic veins during transjugular intrahepatic portosystemic shunt (TIPSS). We included six consecutive patients with fulminant/acute Budd-Chiari syndrome (mean age: 35 years) in whom a conventional TIPSS was not possible due to inaccessible hepatic veins. We performed a direct porto-caval shunt via a transhepatic approach. Patients were followed up by means of clinical examination, laboratory investigations, and Doppler ultrasound. TIPSS implantation from the inferior vena cava (IVC) was successful in all six patients (100%). The median transhepatic shunt length was 9 cm (8-10 cm). No procedure-related complications were observed in our patients. Early shunt occlusion occurred in three out of six patients (50%). In all three of these patients, the stent used to stabilize the shunt ended 1-2 cm before reaching the IVC. All occlusions were successfully recanalized. One of these patients developed recurrent early shunt as well as mesenteric and splenic vein occlusions. She died 7 days after TIPSS placement due to an unmanageable coagulation disorder. The remaining five patients were followed up by planned clinical examination and laboratory investigations (mean follow-up time was 15 months; patient 1 was followed up for 13 months, patient 2 for 14 months, patient 3 for 15 months, and patients 4 and 5 for 16 months) and all displayed a complete and durable resolution of liver failure and ascites without reintervention. In patients with acute liver failure originating from BCS and inaccessible hepatic veins, a direct transhepatic porto-caval shunt can be performed safely and effectively under ultrasound guidance. Future studies in larger patient groups should investigate if the patency of transcaval TIPSS with long transhepatic shunt segments is similar compared to conventional TIPSS via

  11. Developmental intrahepatic shunts of childhood: radiological features and management

    International Nuclear Information System (INIS)

    Paley, M.R.; Farrant, P.; Kane, P.; Karani, J.B.; Heaton, N.D.; Howard, E.R.

    1997-01-01

    The purpose of this study was to evaluate the role of radiological techniques in the diagnosis and management of developmental intrahepatic shunts. Hepatic vascular fistulae are recognised sequelae of liver trauma and intrahepatic tumours. However, there are rare developmental malformations which may present in childhood or later life and which may carry life-threatening complications. Retrospective analysis of clinical and radiological data was carried out in 24 patients. Anomalies evaluated were: (a) direct communication between hepatic artery and hepatic veins; (b) congenital hepatoportal arteriovenous malformations; and (c) congenital portocaval anastomosis with persistent flow through the ductus venosus. Although rare, the prompt recognition of these vascular anomalies allows early surgical or radiological intervention and reversal of the haemodynamic complications. (orig.)

  12. Developmental intrahepatic shunts of childhood: radiological features and management

    Energy Technology Data Exchange (ETDEWEB)

    Paley, M.R.; Farrant, P.; Kane, P.; Karani, J.B. [Department of Radiology, King`s College Hospital, Denmark Hill, London SE5 9RS (United Kingdom); Heaton, N.D.; Howard, E.R. [Department of Paediatric Hepatobiliary Surgery, King`s College Hospital Denmark Hill, London SE5 9RS (United Kingdom)

    1997-12-01

    The purpose of this study was to evaluate the role of radiological techniques in the diagnosis and management of developmental intrahepatic shunts. Hepatic vascular fistulae are recognised sequelae of liver trauma and intrahepatic tumours. However, there are rare developmental malformations which may present in childhood or later life and which may carry life-threatening complications. Retrospective analysis of clinical and radiological data was carried out in 24 patients. Anomalies evaluated were: (a) direct communication between hepatic artery and hepatic veins; (b) congenital hepatoportal arteriovenous malformations; and (c) congenital portocaval anastomosis with persistent flow through the ductus venosus. Although rare, the prompt recognition of these vascular anomalies allows early surgical or radiological intervention and reversal of the haemodynamic complications. (orig.) With 7 figs., 4 tabs., 22 refs.

  13. Analysis of new actuation methods for capacitive shunt micro switchs

    Directory of Open Access Journals (Sweden)

    Ben Sassi S

    2016-01-01

    Full Text Available This work investigates the use of new actuation methods in capacitive shunt micro switches. We formulate the coupled electromechanical problem by taking into account the fringing effects and nonlinearities due to mid-plane stretching. Static analysis is undertaken using the Differential Quadrature Method (DQM to obtain the pull in voltage which is verified by means of the Finite Element Method (FEM. Based on Galerkin approximation, a single degree of freedom dynamic model is developed and limit-cycle solutions are calculated using the Finite Difference Method (FDM. In addition to the harmonic waveform signal, we apply novel actuation waveform signals to simulate the frequency-response. We show that, biased signals, using a square wave signal reduces significantly the pull-in voltage compared to the triangular and harmonic signal . Finally, these results are validated experimentally.

  14. CT-control of the H-graft interposition mesocaval shunt patency

    Energy Technology Data Exchange (ETDEWEB)

    Partanen, P L.K.; Oksala, I

    1984-02-01

    A method for assessing the patency of the H-graft interposition mesocaval shunts by computerized tomography is described. Five patients with such shunts were examined with a 5.5 second CT scanner. After locating the graft a 50 cc bolus of 76% diatrizoate was injected into a cubital vein and 3-4 scans were executed at a preselected level. A distinct vessel like enhancement appeared if the shunt was open. With dynamic CT-scanning the flow can be demonstrated in graphical form as time-density curves.

  15. Intrahepatic Portosystemic Venous Shunt: Successful Embolization Using the Amplatzer Vascular Plug II

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Ju; Shin, Byung Seok; Lee, In Ho; Ohm, Joon Young; Lee, Byung Seok; Ahn, Moon Sang [Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon (Korea, Republic of); Kim, Ho Jun [Dept. of Radiology, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2012-11-15

    A 67-year-old woman presented with memory impairment and behavioral changes. Brain MRI indicated hepatic encephalopathy. Abdominal CT scans revealed an intrahepatic portosystemic venous shunt that consisted of two shunt tracts to the aneurysmal sac that communicated directly with the right hepatic vein. The large tract was successfully occluded by embolization using the newly available AMPLATZERTM Vascular Plug II and the small tract was occluded by using coils. The patient's symptoms disappeared after shunt closure and she remained free of recurrence at the 3-month follow-up evaluation.

  16. Detection of intracardiac shunts with contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Manning, W.J.; Atkinson, D.J.; Parker, J.A.; Edelman, R.R.

    1990-01-01

    This paper reports on ultrafast MR imaging with bolus administration of Gd-DTPA used to detect intracardiac shunts. Ten patients who had recently undergone cardiac catheterization or first-pass radionuclide evaluation were selected for study. These included five patients without intracardiac shunts and five patients with shunts (three with atrial septal defect, two with ventricular septal defect). Resting four-chamber cardiac images were obtained during intravenous injection of Gd-DTPA (0.02 mmol/kg) with an ultrafast, T1-weighted sequence. Images were acquired over 380 msec, with repetitive images obtained with each QRS for 50 beats. In addition, standard MR cine examinations were performed

  17. Tunable elastic parity-time symmetric structure based on the shunted piezoelectric materials

    Science.gov (United States)

    Hou, Zhilin; Assouar, Badreddine

    2018-02-01

    We theoretically and numerically report on the tunable elastic Parity-Time (PT) symmetric structure based on shunted piezoelectric units. We show that the elastic loss and gain can be archived in piezoelectric materials when they are shunted by external circuits containing positive and negative resistances. We present and discuss, as an example, the strongly dependent relationship between the exceptional points of a three-layered system and the impedance of their external shunted circuit. The achieved results evidence that the PT symmetric structures based on this proposed concept can actively be tuned without any change of their geometric configurations.

  18. Two-port laparoscopic management of a giant pseudocyst complicating ventriculoperitoneal shunt

    Directory of Open Access Journals (Sweden)

    Sandesh V Parelkar

    2014-01-01

    Full Text Available Insertion of a ventriculo-peritoneal (VP shunt is the most common operative procedure for the treatment of hydrocephalus in children. Of the several causes of shunt malfunction, cerebrospinal fluid (CSF pseudocyst is relatively uncommon. There are several modalities to treat a CSF pseudocyst. Laparotomy is required, at times, more than once. We managed a patient of CSF pseudocyst with two-port laparoscopy, by deroofing the psuedocyst and repositioning of the shunt. This minimally invasive technique avoids morbidity associated with laparotomy and aids in early recovery.

  19. Brain abscesses associated with right-to-left shunts in adults.

    Science.gov (United States)

    Memon, Kashif A; Cleveland, Kerry O; Gelfand, Michael S

    2012-04-01

    Although brain abscesses are frequently cryptogenic in origin, bacteria must reach the brain either by direct or hematogenous spread. Right-to-left shunts, caused either by intrapulmonary vascular malformations or congenital heart defects, may allow microorganisms to evade the normal host defenses in the lungs and lead to development of brain abscesses. Two patients recently presented with brain abscesses and were found to have conditions associated with right-to-left shunts. The diagnosis of brain abscess should prompt the clinician to consider right-to-left shunts as a possible predisposing condition for brain abscess.

  20. Scrotal migration of ventriculoperitoneal shunt: a case report at Haji Adam Malik hospital, Medan

    Science.gov (United States)

    Dharmajaya, R.

    2018-03-01

    Ventriculoperitoneal (VP) shunting is one of the most common pediatric neurosurgery operations performed for dealing with hydrocephalus. We report an unusual case of a 1-year-old child with communicating hydrocephalus, who experienced right scrotum swelling after 11 months of shunting. Abdominal x-ray showed the shunt tubing, which was kinked in its distal portion of thescrotum. Ultrasound examination was performed, revealing hydrocele along with the presence of thedistal catheter in the scrotum. The patient underwent distal catheter trimming via laparoscopic approach with general surgery and managed with asuccessful outcome. Prompt surgical management of catheter repositioning is recommended to avoid the risk of further complications.

  1. Severe Juxtahepatic Venous Injury: Survival after Prolonged Hepatic Vascular Isolation Without Shunting

    Directory of Open Access Journals (Sweden)

    J. E. J. Krige

    1990-01-01

    Full Text Available Survival following major juxtahepatic venous injury is rare in blunt liver trauma despite the use of intracaval shunting. Prolonged liver arterial inflow control, total hepatic venous isolation and lobectomy without shunting was used in a patient to repair a combined vena caval and hepatic venous injury after blunt liver injury. An extended period of normothermic hepatic ischemia was tolerated. Early recognition of retrohepatic venous injury and temporary liver packing to control bleeding and correct hypovolemia are essential before caval occlusion. Hepatic vascular isolation without shunting is an effective simple alternative technique allowing major venous repair in complex liver trauma.

  2. The design and implementation of on-line monitoring system for UHV compact shunt capacitors

    Science.gov (United States)

    Tao, Weiliang; Ni, Xuefeng; Lin, Hao; Jiang, Shengbao

    2017-08-01

    Because of the large capacity and compact structure of the UHV compact shunt capacitor, it is difficult to take effective measures to detect and prevent the faults. If the fault capacitor fails to take timely maintenance, it will pose a threat to the safe operation of the system and the life safety of the maintenance personnel. The development of UHV compact shunt capacitor on-line monitoring system can detect and record the on-line operation information of UHV compact shunt capacitors, analyze and evaluate the early fault warning signs, find out the fault capacitor or the capacitor with fault symptom, to ensure safe and reliable operation of the system.

  3. Establishing Connectivity

    DEFF Research Database (Denmark)

    Kjær, Poul F.

    Global law settings are characterised by a structural pre-eminence of connectivity norms, a type of norm which differs from coherency or possibility norms. The centrality of connectivity norms emerges from the function of global law, which is to increase the probability of transfers of condensed ...... and human rights can be understood as serving a constitutionalising function aimed at stabilising and facilitating connectivity. This allows for an understanding of colonialism and contemporary global governance as functional, but not as normative, equivalents.......Global law settings are characterised by a structural pre-eminence of connectivity norms, a type of norm which differs from coherency or possibility norms. The centrality of connectivity norms emerges from the function of global law, which is to increase the probability of transfers of condensed...... social components, such as economic capital and products, religious doctrines and scientific knowledge, from one legally structured context to another within world society. This was the case from colonialism and colonial law to contemporary global supply chains and human rights. Both colonial law...

  4. Nuclear reactor apparatus

    International Nuclear Information System (INIS)

    Braun, H.E.; Bonnet, H.P.

    1978-01-01

    The reactor and its containment, instead of being supported on a solid concrete pad, are supported on a truss formed of upper and lower reinforced horizontal plates and vertical walls integrated into a rigid structure. The plates and walls from chambers within which the auxiliary components of the reactor, such as valves, pumping equipment and various tanks, are disposed. Certain of the chambers are also access passages for personnel, pipe chases, valve chambers and the like. In particular the truss includes an annular chamber. This chamber is lined and sealed by a corrosion-resistant liner and contains coolant and serves as a refueling cooling storage tank. This tank is directly below the primary-coolant conductor loops which extend from the reactor above the upper plate. The upper plate includes a sump connected to the tank through which coolant flows into the tank in the event of the occurrence of a loss-of-coolant accident. The truss extends beyond the containment and has chambers in the extending annulus. Pumps for circulating the coolant between the refueling coolant storage tank and the reactor are provided in certain of these chambers. The pumps are connected to the reactor by relatively short coolant conductors. Access to these pumps is readily afforded through hatches in the extending annulus

  5. Reactor containing facility

    International Nuclear Information System (INIS)

    Akagawa, Katsuhiko.

    1992-01-01

    A cooling space having a predetermined capacity is formed between a reactor container and concrete walls. A circulation loop disposed to the outside of the concrete walls is connected to the top and the bottom of the cooling space. The circulation loop has a circulation pump and a heat exchanger, and a cooling water supply pipe is connected to the upstream of the circulation pump for introducing cooling water from the outside. Upon occurrence of loss of coolant accident, cooling water is introduced from the cooling water supply pipe to the cooling space between the reactor container and the concrete walls after shut-down of the reactor operation. Then, cooling water is circulated while being cooled by the heat exchanger, to cool the reactor container by cooling water flown in the cooling space. This can cool the reactor container in a short period of time upon occurrence of the loss of coolant accident. Accordingly, a repairing operation for a ruptured portion can be conducted rapidly. (I.N.)

  6. Shunt occlusion for portosystemic shunt syndrome related refractory hepatic encephalopathy-A single-center experience in 21 patients from Kerala.

    Science.gov (United States)

    Philips, Cyriac Abby; Kumar, Lijesh; Augustine, Philip

    2017-09-01

    Large spontaneous portosystemic shunts (SPSS) are seen in a subset of patients with liver disease and medically refractory recurrent/persistent hepatic encephalopathy (MRHE). Shunt occlusion has been shown to improve clinical outcomes. We retrospectively analyzed patient characteristics, SPSS attributes, procedural features, baseline clinical and investigational parameters, neurological outcomes, adverse effects (procedure and portal hypertension related), and risk factors predicting outcomes in liver disease patients undergoing shunt occlusion procedure for MRHE. Between October 2016 and July 2017, 21 patients (Child-Pugh score, CTP 6 to 13) with mean model of end-stage liver disease (MELD) and MELD-sodium scores 15.7 and 19.3 respectively with MRHE [3-cirrhotic Parkinsonism (CP)] were diagnosed to have single or multiple large SPSSs. A total of 29 shunts were occluded (1 surgical, 20 non-surgical). Recurrent and persistent HE and CP markedly improved in the short (n=20, 1 to 3 months), intermediate (n=12, 3 to 6 months), and long (n=7, 6 to 9 months) follow up. None had spontaneous or persistent HE at a median follow up 105 (30 to 329) days (p11 predicted mortality post shunt occlusion (p=0.04). Embolization of large SPSS in liver disease patients with MRHE and modestly preserved liver function is safe and efficacious and associated with improved quality of life and can function as a bridge to liver transplantation in accurately selected patients.

  7. Reactor Physics

    International Nuclear Information System (INIS)

    Ait Abderrahim, A.

    2002-01-01

    SCK-CEN's Reactor Physics and MYRRHA Department offers expertise in various areas of reactor physics, in particular in neutron and gamma calculations, reactor dosimetry, reactor operation and control, reactor code benchmarking and reactor safety calculations. This expertise is applied in the Department's own research projects in the VENUS critical facility, in the BR1 reactor and in the MYRRHA project (this project aims at designing a prototype Accelerator Driven System). Available expertise is also used in programmes external to the Department such as the reactor pressure steel vessel programme, the BR2 materials testing reactor dosimetry, and the preparation and interpretation of irradiation experiments by means of neutron and gamma calculations. The activities of the Fuzzy Logic and Intelligent Technologies in Nuclear Science programme cover several domains outside the department. Progress and achievements in these topical areas in 2001 are summarised

  8. Reactor Physics

    Energy Technology Data Exchange (ETDEWEB)

    Ait Abderrahim, A

    2001-04-01

    The Reactor Physics and MYRRHA Department of SCK-CEN offers expertise in various areas of reactor physics, in particular in neutronics calculations, reactor dosimetry, reactor operation, reactor safety and control and non-destructive analysis of reactor fuel. This expertise is applied in the Department's own research projects in the VENUS critical facility, in the BR1 reactor and in the MYRRHA project (this project aims at designing a prototype Accelerator Driven System). Available expertise is also used in programmes external to the Department such as the reactor pressure steel vessel programme, the BR2 reactor dosimetry, and the preparation and interpretation of irradiation experiments by means of neutron and gamma calculations. The activities of the Fuzzy Logic and Intelligent Technologies in Nuclear Science programme cover several domains outside the department. Progress and achievements in these topical areas in 2000 are summarised.

  9. Reactor Physics

    Energy Technology Data Exchange (ETDEWEB)

    Ait Abderrahim, A

    2002-04-01

    SCK-CEN's Reactor Physics and MYRRHA Department offers expertise in various areas of reactor physics, in particular in neutron and gamma calculations, reactor dosimetry, reactor operation and control, reactor code benchmarking and reactor safety calculations. This expertise is applied in the Department's own research projects in the VENUS critical facility, in the BR1 reactor and in the MYRRHA project (this project aims at designing a prototype Accelerator Driven System). Available expertise is also used in programmes external to the Department such as the reactor pressure steel vessel programme, the BR2 materials testing reactor dosimetry, and the preparation and interpretation of irradiation experiments by means of neutron and gamma calculations. The activities of the Fuzzy Logic and Intelligent Technologies in Nuclear Science programme cover several domains outside the department. Progress and achievements in these topical areas in 2001 are summarised.

  10. Reactor Physics

    International Nuclear Information System (INIS)

    Ait Abderrahim, A.

    2001-01-01

    The Reactor Physics and MYRRHA Department of SCK-CEN offers expertise in various areas of reactor physics, in particular in neutronics calculations, reactor dosimetry, reactor operation, reactor safety and control and non-destructive analysis of reactor fuel. This expertise is applied in the Department's own research projects in the VENUS critical facility, in the BR1 reactor and in the MYRRHA project (this project aims at designing a prototype Accelerator Driven System). Available expertise is also used in programmes external to the Department such as the reactor pressure steel vessel programme, the BR2 reactor dosimetry, and the preparation and interpretation of irradiation experiments by means of neutron and gamma calculations. The activities of the Fuzzy Logic and Intelligent Technologies in Nuclear Science programme cover several domains outside the department. Progress and achievements in these topical areas in 2000 are summarised

  11. Modelling of a falling sludge bed reactor using AQUASIM | Ristow ...

    African Journals Online (AJOL)

    Modelling of a falling sludge bed reactor using AQUASIM. ... AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING AJOL · RESOURCES ... a system of mixed reactors connected by water flow and mass flux streams.

  12. Connected Traveler

    Energy Technology Data Exchange (ETDEWEB)

    2016-06-01

    The Connected Traveler framework seeks to boost the energy efficiency of personal travel and the overall transportation system by maximizing the accuracy of predicted traveler behavior in response to real-time feedback and incentives. It is anticipated that this approach will establish a feedback loop that 'learns' traveler preferences and customizes incentives to meet or exceed energy efficiency targets by empowering individual travelers with information needed to make energy-efficient choices and reducing the complexity required to validate transportation system energy savings. This handout provides an overview of NREL's Connected Traveler project, including graphics, milestones, and contact information.

  13. Reactor operation

    CERN Document Server

    Shaw, J

    2013-01-01

    Reactor Operation covers the theoretical aspects and design information of nuclear reactors. This book is composed of nine chapters that also consider their control, calibration, and experimentation.The opening chapters present the general problems of reactor operation and the principles of reactor control and operation. The succeeding chapters deal with the instrumentation, start-up, pre-commissioning, and physical experiments of nuclear reactors. The remaining chapters are devoted to the control rod calibrations and temperature coefficient measurements in the reactor. These chapters also exp

  14. Reactor safeguards

    CERN Document Server

    Russell, Charles R

    1962-01-01

    Reactor Safeguards provides information for all who are interested in the subject of reactor safeguards. Much of the material is descriptive although some sections are written for the engineer or physicist directly concerned with hazards analysis or site selection problems. The book opens with an introductory chapter on radiation hazards, the construction of nuclear reactors, safety issues, and the operation of nuclear reactors. This is followed by separate chapters that discuss radioactive materials, reactor kinetics, control and safety systems, containment, safety features for water reactor

  15. Emergency reactor container cooling facility

    International Nuclear Information System (INIS)

    Suzuki, Hiroaki; Matsumoto, Tomoyuki.

    1992-01-01

    The present invention concerns an emergency cooling facility for a nuclear reactor container having a pressure suppression chamber, in which water in the suppression chamber is effectively used for cooling the reactor container. That is, the lower portion of a water pool in the pressure suppression chamber and the inside of the reactor container are connected by a pipeline. The lower end of the pipeline and a pressurized incombustible gas tank disposed to the outside of the reactor container are connected by a pipeline by way of valves. Then, when the temperature of the lower end of the pressure vessel exceeds a predetermined value, the valves are opened. If the valves are opened, the incombustible gas flows into the lower end of the pipeline connecting the lower portion of the water pool in the pressure suppression chamber and the inside of the reactor container. Since the inside of the pipeline is a two phase flow comprising a mixture of a gas phase and a liquid phase, the average density is decreased. Therefore, the water level of the two phase flow is risen by the level difference between the inside and the outside of the pipeline and, finally, the two phase mixture is released into the reactor container. As a result, the reactor container can be cooled by water in the suppression chamber by a static means without requiring pumps. (I.S.)

  16. Metformin reduces intrahepatic fibrosis and intrapulmonary shunts in biliary cirrhotic rats

    Directory of Open Access Journals (Sweden)

    Mu-Tzu Ko

    2017-08-01

    Conclusion: Metformin reduced liver injury and improved hepatic fibrosis in cirrhotic rats. It also attenuated the intrapulmonary shunts. However, the effects of metformin on pulmonary angiogenesis and hypoxia were insignificant.

  17. The transjugular portosystemic stent shunt (TIPSS) as an intervention in clinical complication of portal hypertension

    International Nuclear Information System (INIS)

    Thalhammer, A.; Jacobi, V.; Schwarz, W.; Balzer, J.; Abolmaali, N.; Vogl, T.J.

    2001-01-01

    Most frequent complications in patients with liver cirrhosis are due to portal hypertension. Beside ascites circumvent vessles formate with vasodilatation. Due to counterregulation a secondary hyperaldosteronism develops with release of vasocontrictive agents. If conservative and endoscopic methods fail, indication for building a portosystemic shunt is given. The TIPSS procedure is less invasive than the surgical method of Warren-Shunt, so the radiological intervention has replaced surgery. Reducing the portal pressure by the shunt, the clinical complications change for the better. Still problems are defined as hepatic encephalopathy and right ventricular heart failure. Regular follow up investigations have to be performed to detect complications in the shunt. Using regular clinical and radiological check up TIPSS is of clinical benefit with good long term results. (orig.) [de

  18. Bacterial contamination of surgeons' gloves during shunt insertion; a pilot study

    DEFF Research Database (Denmark)

    Sørensen, Preben; Ejlertsen, Tove; Aaen, Dorte

    2008-01-01

    antibiotics and double gloving, by surgeons experienced in shunt surgery. Surgical incision, dissection and tunnelling were done. Then the surgeon, the scrub-nurse and, in three cases, the assistant made an imprint of their outer gloves on agar plates. Hereafter, they changed the outer pair of gloves before...... handling the shunt and completing the operation. The plates were cultured for 6 days in both aerobic and anaerobic environment. In all cases the surgeons gloves were contaminated, and in six cases also the nurses' gloves were contaminated, as well as all three assistants. Propionebacterium acnes were...... nurse and assistant were contaminated with micro-organisms less than 15 min after surgery has been commenced and before the shunts were handled. This study offers a feasible, simple and logical explanation of how shunts may become contaminated and infected. A simple measure would be to change the outer...

  19. Staphylococcus warneri ventriculoperitoneal shunt infection: failure of diagnosis by ventricular CSF sampling.

    Science.gov (United States)

    Martínez-Lage, Juan F; Martínez-Lage Azorín, Laura; Almagro, María-José

    2010-12-01

    The definite diagnosis of hydrocephalus valve infection is generally made by cerebrospinal fluid (CSF) sampling via the valve reservoir, which is considered to be more dependable than that of the CSF obtained by lumbar puncture. We treated a 17-year-old boy with an intra-abdominal pseudocyst due to ventriculoperitoneal shunt infection caused by Staphylococcus warneri whose ventricular CSF, obtained via the valve reservoir, was repeatedly sterile thus causing a considerable delay in the management of the complication. S. warneri constitutes an emergent contaminant of catheters and prostheses. We found only a detailed report of S. warneri infection of a ventriculoatrial shunt. If manifestations of peritoneal involvement in shunted patients would occur, the attention should be shifted to the distal component of the shunt hardware, even in the presence of a normal ventricular CSF as happened in our case to avoid unnecessary delay in diagnosis and management.

  20. Harmonics reduction in standalone DFIG-DC system by shunt active ...

    Indian Academy of Sciences (India)

    Himanshu Misra

    2018-05-22

    May 22, 2018 ... Doubly fed induction generator; standalone; DC voltage regulation; shunt active filter; harmonics ... Operation and design issue of DFIG in DC-net interface is ...... control systems for the operation of DFIGs in wind energy.

  1. Design and test of a novel isolator with negative resistance electromagnetic shunt damping

    International Nuclear Information System (INIS)

    Yan, Bo; Zhang, Xinong; Niu, Hongpan

    2012-01-01

    This paper proposes a negative resistance electromagnetic shunt damping vibration isolator and investigates the effectiveness of the isolator. The isolator consists of a shunt circuit and a pair of electromagnet and permanent magnets that are pasted onto a box-shaped spring. A kind of negative resistance shunt impedance is proposed to cancel the inherent resistance of the electromagnet. The electromechanical coupling coefficient and the electromagnetic damping force calculation formula are obtained by Biot–Savart’s law and Ampère’s law, respectively. A single degree of freedom system is employed to verify the performance of the proposed isolator. The governing equation is established. The performance of the proposed isolator under a half-cycle sine pulse is investigated and discussed. Experiments were carried out and the results agreed well with the numerical predictions. Both the results demonstrate that the negative resistance electromagnetic shunt damping vibration isolator could suppress vibration transmitted to the structure effectively. (paper)

  2. Subdural haematoma complicating shunting for normal pressure hydrocephalus in the setting of concomitant antiplatelet medication

    DEFF Research Database (Denmark)

    Birkeland, Peter; Lauritsen, Jens; Poulsen, Frantz Rom

    2016-01-01

    OBJECTIVE: To report on the occurrence and management of subdural haematoma after shunt implantation for normal pressure hydrocephalus and to determine the risk of recurrence in the setting of antiplatelet medication. METHODS: From a consecutive series of 80 patients implanted with a cerebrospinal...... fluid shunt for normal pressure hydrocephalus, records from 11 patients taking antiplatelet drugs, who subsequently had surgery for subdural haematoma were extracted and retrospectively reviewed. RESULTS: Patients were followed up for a mean of 1819 days after shunt implantation. Subdural haematomas...... reoperations done before the subdural collection disappeared. Only one patient had a late recurrence almost 11 years after shunt implantation. CONCLUSIONS: Subdural haematoma in the setting of a ventriculoperitoneal implantation for normal pressure hydrocephalus and concomitant antiplatelet medication can...

  3. MR imaging of pulsatile CSF movement in hydrocephalus communicans before and after CSF shunt implantation

    International Nuclear Information System (INIS)

    Goldmann, A.; Kunz, U.; Rotermund, F.; Friedrich, J.M.; Schnarkowski, P.

    1992-01-01

    16 patients with hydrocephalus communicans and 5 healthy volunteers were examined to demonstrate the pattern of the pulsatile CSF flow. After implantation of a CSF shunt system the same patients were examined again to show the influence of the shunt on the CSF pulsations. We used a flow-sensitised, cardiac-gated 2D FLASH sequence and analysed the phase and magnitude images. It could be shown that most patients (n=12) had a hyerdynamic pulsatile flow preoperatively. After shunt implantation the pulsatile CSF motion and the clinical symptoms were improved in 8 of these patients. MRI of pulsatile CSF flow movement seems to be a helpful noninvasive tool to estimate the prognosis of a shunt implantation in patients with hydrocephalus communicans. (orig.) [de

  4. Incidence of ischemic lesions by diffusion-weighted imaging after carotid endarterectomy with routine shunt usage

    International Nuclear Information System (INIS)

    Inoue, Tomohiro; Tsutsumi, Kazuo; Adachi, Shinobu; Tanaka, Shota; Yako, Kyoko; Saito, Kuniaki; Kunii, Naoto; Maeda, Keiitirou

    2006-01-01

    Temporary intraluminal shunt was used during 72 consecutive carotid endarterectomies (CEAs) in 61 patients (bilateral CEA in 11 patients) during October 2001 and September 2005. The medical records of these patients were retrospectively reviewed. All procedures were performed with routine shunt insertion without monitoring such as electroencephalography. Pre- and postoperative diffusion-weighted magnetic resonance (MR) imaging was used to detect ischemic complications. Postoperative angiography was performed in 70 cases to detect abnormalities such as major stenosis or dissection of the distal end. Symptomatic ischemic complication occurred in one patient at 1 month. Postoperative diffusion-weighted MR imaging detected new hyperintense lesions in three patients including the symptomatic patient. Postoperative angiography confirmed that the distal end was satisfactory in all cases. The incidence of ischemic lesions of embolic origin after CEA with routine shunt usage is acceptably low if the procedure of shunt device insertion and removal is meticulously conducted. (author)

  5. Optimizing the Shunting Schedule of Electric Multiple Units Depot Using an Enhanced Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Jiaxi Wang

    2016-01-01

    Full Text Available The shunting schedule of electric multiple units depot (SSED is one of the essential plans for high-speed train maintenance activities. This paper presents a 0-1 programming model to address the problem of determining an optimal SSED through automatic computing. The objective of the model is to minimize the number of shunting movements and the constraints include track occupation conflicts, shunting routes conflicts, time durations of maintenance processes, and shunting running time. An enhanced particle swarm optimization (EPSO algorithm is proposed to solve the optimization problem. Finally, an empirical study from Shanghai South EMU Depot is carried out to illustrate the model and EPSO algorithm. The optimization results indicate that the proposed method is valid for the SSED problem and that the EPSO algorithm outperforms the traditional PSO algorithm on the aspect of optimality.

  6. Optimizing the Shunting Schedule of Electric Multiple Units Depot Using an Enhanced Particle Swarm Optimization Algorithm

    Science.gov (United States)

    Jin, Junchen

    2016-01-01

    The shunting schedule of electric multiple units depot (SSED) is one of the essential plans for high-speed train maintenance activities. This paper presents a 0-1 programming model to address the problem of determining an optimal SSED through automatic computing. The objective of the model is to minimize the number of shunting movements and the constraints include track occupation conflicts, shunting routes conflicts, time durations of maintenance processes, and shunting running time. An enhanced particle swarm optimization (EPSO) algorithm is proposed to solve the optimization problem. Finally, an empirical study from Shanghai South EMU Depot is carried out to illustrate the model and EPSO algorithm. The optimization results indicate that the proposed method is valid for the SSED problem and that the EPSO algorithm outperforms the traditional PSO algorithm on the aspect of optimality. PMID:27436998

  7. Two cases of esophageal cancer with portal hypertension: esophagectomy with venous shunt procedure.

    Science.gov (United States)

    Kato, T; Motohara, T; Kaneko, Y; Shikishima, H; Okushiba, S; Kondo, S; Kato, H

    2001-01-01

    We performed venous shunt procedure in the reconstruction of the esophagus after esophagectomy using the gastric tube in two cases of esophageal cancer with portal hypertension due to liver cirrhosis. In both cases, the short-term postoperative course was uneventful, without congestion in the gastric tube. In Case 1 where the short gastric vein had been used as the shunt vein, the long-term postoperative course was also uneventful, without hepatic encephalopathy or hemorrhage from deterioration of the varices of the gastric tube. However, in Case 2 where the left gastroepiploic vein had been used, hepatic encephalopathy developed due to excessive shunt flow. These results suggested that appropriate shunt flow could be expected by using short gastric vein.

  8. Superior vena cava syndrome after pulsatile bidirectional Glenn shunt procedure: Perioperative implications

    Directory of Open Access Journals (Sweden)

    Neema Praveen

    2009-01-01

    Full Text Available Bidirectional superior cavopulmonary shunt (bidirectional Glenn shunt is generally performed in many congenital cardiac anomalies where complete two ventricle circulations cannot be easily achieved. The advantages of BDG shunt are achieved by partially separating the pulmonary and systemic venous circuits, and include reduced ventricular preload and long-term preservation of myocardium. The benefits of additional pulsatile pulmonary blood flow include the potential growth of pulmonary arteries, possible improvement in arterial oxygen saturation, and possible prevention of development of pulmonary arteriovenous malformations. However, increase in the systemic venous pressure after BDG with additional pulsatile blood flow is known. We describe the peri-operative implications of severe flow reversal in the superior vena cava after pulsatile BDG shunt construction in a child who presented for surgical interruption of the main pulmonary artery.

  9. Making connections

    NARCIS (Netherlands)

    Marion Duimel

    2007-01-01

    Original title: Verbinding maken; senioren en internet. More and more older people are finding their way to the Internet. Many people aged over 50 who have only recently gone online say that a new world has opened up for them. By connecting to the Internet they have the feeling that they

  10. CMS Connect

    Science.gov (United States)

    Balcas, J.; Bockelman, B.; Gardner, R., Jr.; Hurtado Anampa, K.; Jayatilaka, B.; Aftab Khan, F.; Lannon, K.; Larson, K.; Letts, J.; Marra Da Silva, J.; Mascheroni, M.; Mason, D.; Perez-Calero Yzquierdo, A.; Tiradani, A.

    2017-10-01

    The CMS experiment collects and analyzes large amounts of data coming from high energy particle collisions produced by the Large Hadron Collider (LHC) at CERN. This involves a huge amount of real and simulated data processing that needs to be handled in batch-oriented platforms. The CMS Global Pool of computing resources provide +100K dedicated CPU cores and another 50K to 100K CPU cores from opportunistic resources for these kind of tasks and even though production and event processing analysis workflows are already managed by existing tools, there is still a lack of support to submit final stage condor-like analysis jobs familiar to Tier-3 or local Computing Facilities users into these distributed resources in an integrated (with other CMS services) and friendly way. CMS Connect is a set of computing tools and services designed to augment existing services in the CMS Physics community focusing on these kind of condor analysis jobs. It is based on the CI-Connect platform developed by the Open Science Grid and uses the CMS GlideInWMS infrastructure to transparently plug CMS global grid resources into a virtual pool accessed via a single submission machine. This paper describes the specific developments and deployment of CMS Connect beyond the CI-Connect platform in order to integrate the service with CMS specific needs, including specific Site submission, accounting of jobs and automated reporting to standard CMS monitoring resources in an effortless way to their users.

  11. Imaging of the ventriculoperitoneal shunt-related complications in infants and children with hydrocephalus

    International Nuclear Information System (INIS)

    Jeon, Se Ok; Kim, Ji Hye; Oh, Eun Young; Hwang, Hee Young; Lee, Seon Kyu; Lee, Eun Joo; Kwak, Min Sook; Kim, Hyung Sik

    1999-01-01

    To evaluate the frequency and imaging findings of various ventriculo-peritoneal shunt-related complications in pediatric patients with hydrocephalus. We retrospectively reviewed 246 plain radiographs, three shuntograms, 53 ultrasounds, 133 CT scans, and 24 MR images obtained before and after the ventriculo-peritoneal shunt procedure in 33 pediatric patients with hydrocephalus. Using preoperative images, the etiology of the hydrocephalus was assessed. Changes in the size and shape of the ventricles, the location and continuity of shunt apparatus, and the presence of any abnormal enhancement, hemorrhage, edema or tissue loss, or other findings of complications, were analyzed on postoperative images ; the frequency and imaging findings of shunt-related complications such as shunt malfunction, infection, homorrhage or isolated ventricle, and complications caused by overdrainage, were thus evaluated. The frequency of such complications was analyzed according to the etiology of the hydrocephalus, and in addition, medical records were reviewed and correlated with imaging findings. In 18 of the 33 patients(54%), a total of 31 complications was detected. These were present in four of five cases (80%) of hydrocephalus caused by meningitis and ventriculitis, seven of twelve (58%) intraventricular hemorrhage, two of four (50%) unknown cases, three of nine (33%) congenital malformations, one of two (50%) tumors, and one (100%) congenital infection. Shunt malfunction was most common (n=15), and was accompanied by findings of enlarged ventricles, periventricular and peritubal edema, and abnormal location of the shunt tube. Symptoms and signs of increased intracranial pressure were also noted. Subdural hemorrhage and infection were present in four cases each ; findings of infection were enhancement of the ventricular wall, meninges, and parenchyma, as well as sonographically noted intraventricular septation and increased ventricular wall echo. Isolated lateral ventricle (n=4) or 4

  12. Die transkranielle Doppler-Sonographie zur Identifikation von Rechts-Links-Shunts

    OpenAIRE

    Jekentaite, R. (Ruta)

    2003-01-01

    Paradoxe Embolien über einen Rechts-Links-Shunt (RLS) stellen eine Ursache von Hirninfarkten dar. Diese Shunts werden mittels TEE oder TCD diagnostiziert. Ziele dieser Studie waren die Bestimmung des optimalen Timings des Valsalva-Manövers (VM) sowie Vergleich der zwei Kontrastmittel Echovist®-300 und Echovist®-200. 64 Patienten wurden mittels beider Methoden untersucht. Nach der KM-Injektion wurden die Mikroemboliesignale (MES) in der ACM bilateral dopplersonographisch registriert. Die Unt...

  13. Spontaneous expectoration of a Blalock-Taussig shunt a decade after operation

    Directory of Open Access Journals (Sweden)

    Shyam S Kothari

    2015-01-01

    Full Text Available An eleven-year-old boy expectorated a foreign body in cough that was identified as the prosthetic graft used for a Blalock-Taussig shunt. The shunt procedure was done 10 years earlier, and a definitive repair for tetralogy of Fallot was done a year later. He had no other symptoms, and a computed tomography (CT angiogram did not reveal any other significant anomaly. The reason for this extremely rare event is unclear.

  14. Noninvasive measurement of nutrient portal blood shunting: an experimental study with [14C]ursodeoxycholic acid

    International Nuclear Information System (INIS)

    Nordlinger, B.; Parquet, M.; Infante, R.; Moreels, R.; Blondiau, P.; Boschat, M.; Groussard, M.; Huguet, C.

    1982-01-01

    All of the methods proposed for measuring portal blood flow are either invasive, estimate total rather than nutrient flow, and none has proved reliable in cirrhotic patients. A method has been derived from pharmacokinetic principles used for the calculation of bioavailability of drugs according to the route of administration (i.v. or p.o.) and tested experimentally in 20 pigs. A tracer dose of [ 14 C]ursodeoxycholic acid, a biliary acid with a high-liver first-pass effect, is administered in the duodenum, and serial peripheral blood samples are taken. Later, the same dose of the same drug is administered i.v. The shunt fraction of portal blood F is obtained by the ratio of the areas under the plasma level vs. time curves (AUC) after p.o. and i.v. administrations: (see formula in text). The pigs were divided into three experimental groups. (i) Group I: undisturbed portal flow; (ii) Group II: total diversion of portal blood with an end-to-side portacaval shunt, and (iii) Group III: partial diversion of portal blood through a side-to-side portacaval shunt. Portal flow was measured during surgery with an electromagnetic flowmeter above and below the shunt and the degree of shunting calculated. Results show that the shunt fraction measured with ursodeoxycholic acid is well-correlated with hemodynamic data. No overlap between Groups I and III is observed. It is concluded that the shunt fraction of nutrient portal blood can be measured with this noninvasive method. Minute amounts of ursodeoxycholic acid were used in order to be completely metabolized by the liver, even in spite of hepatocellular dysfunction. Therefore, this method should be valid in cirrhotic patients and be useful to decide the type of portasystemic shunt to propose for the decompression of gastroesophageal varices

  15. Transdiaphragmatic Approach to Attenuate Porto-Azygos Shunts Inserting in the Thorax.

    Science.gov (United States)

    Or, Matan; Kitshoff, Adriaan; Devriendt, Nausikaa; De Ridder, Marianne; Quist-Rybachuk, Galena; de Rooster, Hilde

    2016-11-01

    To describe the surgical technique and document the application of a transdiaphragmatic approach to attenuate porto-azygos shunts inserting in the thoracic section of the azygos vein. Cadaveric study and prospective case series. Canine cadavers (n=6) and client-owned dogs with porto-azygos shunts inserting in the thoracic section of the azygos vein (n=9). In the cadavers, the azygos vein was filled with aqueous latex. Landmarks were established for creating a safe transdiaphragmatic approach to the caudal intrathoracic portion of the azygos vein. In the clinical cases, porto-azygos communication was diagnosed by trans-splenic portal scintigraphy. All shunts were attenuated close to their insertion site via ventral midline celiotomy and a transdiaphragmatic approach to the shunt. Perioperative complications were recorded. A 3-5 cm incision, 0.5-1 cm ventral and lateral to the level of the aortic hiatus, was made in the pars lumbalis part of the diaphragm. Stay sutures at both sides of the diaphragmatic incision were placed to open up the incision and a retractor was used to push the esophagus away from the aorta. Intrathoracic insertion of the shunt was confirmed intraoperative. Exposure of the shunt insertion site at the azygos vein was excellent in all clinical cases. No intraoperative or postoperative complications were encountered. If thoracic attenuation of a porto-azygos shunt is considered, a transdiaphragmatic approach exposes the insertion site for shunt attenuation. This approach is straightforward, without unnecessary abdominal organ manipulation, and since attenuates at the insertion, avoids missing additional contributing branches. © Copyright 2016 by The American College of Veterinary Surgeons.

  16. Modified temporary end-to-side portocaval shunt in liver and small bowel transplantation.

    Science.gov (United States)

    Molmenti, E P; Marsh, J W; Molmenti, H; Reyes, J; Fung, J J

    2001-10-01

    Piggyback orthotopic liver transplantation (LTx) has permitted the elimination of extra-corporeal venovenous bypass. In some instances, an internal temporary portocaval shunt has to be constructed in order to prevent hemodynamic instability. We describe a technique in which a donor iliac vein graft is used to bridge the distance between the portal vein and vena cava in cases where a direct shunt cannot be constructed. This technique can be applied to liver Tx as well as to liver and small bowel Tx.

  17. Abnormal Gas Diffusing Capacity and Portosystemic Shunt in Patients With Chronic Liver Disease

    OpenAIRE

    Park, Moon-Seung; Lee, Min-Ho; Park, Yoo-Sin; Kim, Shin-Hee; Kwak, Min-Jung; Kang, Ju-Seop

    2012-01-01

    Background Pulmonary dysfunctions including the hepatopulmonary syndrome and portosystemic shunt are important complications of hepatic cirrhosis. To investigate the severity and nature of abnormal gas diffusing capacity and its correlation to portosystemic shunt in patients with chronic liver disease. Methods Forty-four patients with chronic liver disease (15 chronic active hepatitis (CAH), 16 Child-Pugh class A, and 13 Child-Pugh class B) without other diseases history were enrolled in the ...

  18. Incorporation of distributed generation and shunt capacitor in radial distribution system for techno-economic benefits

    Directory of Open Access Journals (Sweden)

    Mukul Dixit

    2017-04-01

    The various costs such as purchase active power from grid, DG installation, capacitor installation, DG Operation and Maintenance (O&M are evaluated at two different load scenarios. In addition to that, technical and economical analyses are examined for various combinations of DGs and shunt capacitors. The proposed methodology is successfully demonstrated on 33-bus and 85-bus radial networks and the obtained numerical outcomes validate the suitability, importance and effectiveness to identify locations as well as sizes of DGs and shunt capacitors.

  19. Reactor operation method

    International Nuclear Information System (INIS)

    Osumi, Katsumi; Miki, Minoru.

    1979-01-01

    Purpose: To prevent stress corrosion cracks by decreasing the dissolved oxygen and hydrogen peroxide concentrations in the coolants within a reactor container upon transient operation such as at the start-up or shutdown of bwr type reactors. Method: After a condensate has been evacuated, deaeration operation is conducted while opening a main steam drain line, as well as a main steam separation valve and a by-pass valve in a turbine by-pass line connecting the main steam line and the condenser without by way of a turbine, and the reactor is started-up by the extraction of control rods after the concentration of dissolved oxygen in the cooling water within a pressure vessel has been decreased below a predetermined value. Nuclear heating is started after the reactor water has been increased to about 150 0 C by pump heating after the end of the deaeration operation for preventing the concentration of hydrogen peroxide and oxygen in the reactor water from temporarily increasing immediately after the start-up. The corrosive atmosphere in the reactor vessel can thus be moderated. (Horiuchi, T.)

  20. Nuclear reactors

    International Nuclear Information System (INIS)

    Middleton, J.E.

    1977-01-01

    Reference is made to water cooled reactors and in particular to the cooling system of steam generating heavy water reactors (SGHWR). A two-coolant circuit is described for the latter. Full constructural details are given. (U.K.)

  1. Reactor decommissioning

    International Nuclear Information System (INIS)

    Lawton, H.

    1984-01-01

    A pioneering project on the decommissioning of the Windscale Advanced Gas-cooled Reactor, by the UKAEA, is described. Reactor data; policy; waste management; remote handling equipment; development; and recording and timescales, are all briefly discussed. (U.K.)

  2. Sodium-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Hammers, H.W.

    1982-01-01

    The invention concerns a sodium-cooled nuclear reactor, whose reactor tank contains the primary circuit, shielding surrounding the reactor core and a primary/secondary heat exchanger, particularly a fast breeder reactor on the module principle. In order to achieve this module principle it is proposed to have electromagnetic circulating pumps outside the reactor tank, where the heat exchanger is accomodated in an annular case above the pumps. This case has several openings at the top end to the space above the reactor core, some smaller openings in the middle to the same space and is connected at the bottom to an annular space between the tank wall and the reactor core. As a favoured variant, it is proposed that the annular electromagnetic pumps should be arranged concentrically to the reactor tank, where there is an annual duct on the inside of the reactor tank. In this way the sodium-cooled nuclear reactor is made suitable as a module with a large number of such elements. (orig.) [de

  3. RB research reactor safety report

    International Nuclear Information System (INIS)

    Sotic, O.; Pesic, M.; Vranic, S.

    1979-04-01

    This new version of the safety report is a revision of the safety report written in 1962 when the RB reactor started operation after reconstruction. The new safety report was needed because reactor systems and components have been improved and the administrative procedures were changed. the most important improvements and changes were concerned with the use of highly enriched fuel (80% enriched), construction of reactor converter outside the reactor vessel, improved control system by two measuring start-up channels, construction of system for heavy water leak detection, new inter phone connection between control room and other reactor rooms. This report includes description of reactor building with installations, rector vessel, reactor core, heavy water system, control system, safety system, dosimetry and alarm systems, experimental channels, neutron converter, reactor operation. Safety aspects contain analyses of accident reasons, method for preventing reactivity insertions, analyses of maximum hypothetical accidents for cores with natural uranium, 2% enriched and 80% enriched fuel elements. Influence of seismic events on the reactor safety and well as coupling between reactor and the converter are parts of this document

  4. Backfitting of the FRG reactors

    International Nuclear Information System (INIS)

    Krull, W.

    1990-01-01

    The FRG-research reactors The GKSS-research centre is operating two research reactors of the pool type fueled with MTR-type type fuel elements. The research reactors FRG-1 and FRG-2 having power levels of 5 MW and 15 MW are in operation for 31 year and 27 years respectively. They are comparably old like other research reactors. The reactors are operating at present at approximately 180 days (FRG-1) and between 210 and 250 days (FRG-2) per year. Both reactors are located in the same reactor hall in a connecting pool system. Backfitting measures are needed for our and other research reactors to ensure a high level of safety and availability. The main backfitting activities during last ten years were concerned with: comparison of the existing design with today demands (criteria, guidelines, standards etc.); and probability approach for events from outside like aeroplane crashes and earthquakes; the main accidents were rediscussed like startup from low and full power, loss of coolant flow, loss of heat sink, loss of coolant and fuel plate melting; a new reactor protection system had to be installed, following today's demands; a new crane has been installed in the reactor hall. A cold neutron source has been installed to increase the flux of cold neutrons by a factor of 14. The FRG-l is being converted from 93% enriched U with Alx fuel to 20% enriched U with U 3 Si 2 fuel. Both cooling towers were repaired. Replacement of instrumentation is planned

  5. Intracranial Pressure-Guided Shunt Valve Adjustments with the Miethke Sensor Reservoir.

    Science.gov (United States)

    Antes, Sebastian; Stadie, Axel; Müller, Simon; Linsler, Stefan; Breuskin, David; Oertel, Joachim

    2018-01-01

    Telemetric intracranial pressure (ICP) monitoring seems to be a promising therapy-supporting option in shunt-treated patients. Benefits become obvious when headaches are unspecific and clinical symptoms cannot be related to possible overdrainage or underdrainage. In this study, we evaluated a new telemetric device to individually adjust shunt valves according to ICP measurements. Between December 2015 and November 2016, 25 patients with suspected suboptimal shunt valve settings underwent insertion of a telemetric ICP sensor (Sensor Reservoir; Christoph Miethke, Potsdam, Germany). Over a 1-year period, a total of 183 telemetric ICP measurements and 85 shunt valve adjustments were carried out. Retrospective statistic analyses focused on valve adjustments, ICP values, and clinical outcomes. ICP-guided valve adjustments positively changed the clinical state in 18 out of 25 patients. Clinical improvement over time was associated with significant changes of the valve settings and ICP values. Interestingly, a therapeutically normalized ICP profile was not automatically associated with clinical improvement. The Sensor Reservoir is an important and valuable tool for shunt-treated patients suffering from drainage-related problems. The possibility to simultaneously recognize and solve shunt problems represents the decisive advantage. Nevertheless, measurements with the Sensor Reservoir did not allow for the determination of default valve settings or universal target ICP values. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-11-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinoma and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterooportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture.

  7. Demonstration of arterioportal shunt by dynamic computed tomography and its diagnostic value

    International Nuclear Information System (INIS)

    Nakayama, Takatsune; Hiyama, Yoshiaki; Saitoh, Masayuki

    1983-01-01

    Sixty-one patients, 41 with hepatocellular carcinoma and 20 with liver cirrhosis, were examined by dynamic computed tomography (CT) and all but one with hepatocellular carcinoma were examined by celiac angiography. Dynamic CT disclosed arterioportal shunting in eleven cases of hepatocellular carcinima and in one of cirrhotics. All of them were confirmed by angiography except one case in which angiography could not be performed. In ten of these eleven cases arterioportal shunt was adjacent to a mass lesion on dynamic CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In one with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneus needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus dynamic CT was nearly as diagnostic as celiac arterigraphy for the demonstration of arterioportal shunt due to portal invasion of hepatocellular carcinoma and percutaneus needle puncture. (author)

  8. Broadband transmission noise reduction of smart panels featuring piezoelectric shunt circuits and sound-absorbing material.

    Science.gov (United States)

    Kim, Jaehwan; Lee, Joong-Kuen

    2002-09-01

    The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. A piezoelectric smart panel is basically a plate structure on which piezoelectric patches with electrical shunt circuits are mounted and sound-absorbing material is bonded on the surface of the structure. Sound-absorbing material can absorb the sound transmitted at the midfrequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonance frequencies, piezoelectric damping using the measured electrical impedance model is adopted. A resonant shunt circuit for piezoelectric shunt damping is composed of resistor and inductor in series, and they are determined by maximizing the dissipated energy through the circuit. The transmitted noise-reduction performance of smart panels is tested in an acoustic tunnel. The tunnel is a square cross-sectional tube and a loudspeaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in the midfrequency region is observed except for the fundamental resonance frequency of the plate. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive absorbing material and piezoelectric shunt damping is a promising technology for noise reduction over a broadband of frequencies.

  9. Vaginal Migration of Ventriculoperitoneal Shunt Catheter and Cerebrospinal Fluid Leak as a Complication of Hysterectomy.

    Science.gov (United States)

    Houten, John K; Smith, Shiela; Schwartz, Amit Y

    2017-08-01

    Ventriculoperitoneal (VP) shunting is a common neurosurgical procedure to treat hydrocephalus that diverts cerebrospinal fluid from the cerebral ventricles to the peritoneal cavity for reabsorption. The distal catheter may potentially migrate through any potential or iatrogenic opening in the peritoneal cavity. Increasingly successfully management of childhood hydrocephalus and adult-onset conditions leading to hydrocephalus, such as subarachnoid hemorrhage, is leading many adult female patients harboring VP shunts needing to undergo hysterectomy. Hysterectomy creates a potential defect though which a VP shunt catheter may migrate. It is not known whether the hysterectomy cuff closure technique may affect the likelihood of distal catheter migration though the repair site. We report the case of a 38-year-old woman with a VP shunt who underwent laparoscopic hysterectomy via an open vaginal cuff technique who subsequently presented with vaginal cerebrospinal fluid leakage secondary to migration of the distal shunt catheter through the hysterectomy cuff. Vaginal migration of the distal VP shunt catheter is a possible complication of hysterectomy. The authors postulate that an open cuff hysterectomy closure technique may increase the risk of catheter migration, an issue that may be better understood with further investigation. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma.

    Science.gov (United States)

    Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S

    2017-01-01

    To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.

  11. Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.

    Science.gov (United States)

    White, R N; Parry, A T

    2016-05-01

    To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.

  12. A Study on the Measurement of Intrapulmonary Shunt in Liver Diseases by the Nucleolide Method

    International Nuclear Information System (INIS)

    Yun, Sung Chul; Ahn, Jae Hee; Choi, Soo Bong

    1987-01-01

    The fact there are increase of intrapulmonary arteriovenous shunt amount in the liver cirrhosis patient has been known since 1950. And the method of shunt amount calculation by radionuclide method using 99m Tc-MAA was introduced in the middle of 1970. We measured intrapulmonary shunt amount by means of perfusion lung scan using 99m Tc-MAA in the various type of liver diseases especially in chronic liver diseases and acute liver disease. The results were as followed. 1) The amount of arteriovenous intrapulmonary shunt in the total case of liver disease was 9.3±3.9%, and that of in the control group was 4.6±2.1%. 2) The amount of arteriovenous intrapulmonary shunt in the chronic liver disease was 10.8±4.4%, and that of in the acute liver disease was 7.2±2.8%. We observed significant differences between normal control group and liver disease group, and between chronic liver disease group and acute liver disease group in the amount of shunt by the nucleolide method.

  13. Simulation model of harmonics reduction technique using shunt active filter by cascade multilevel inverter method

    Science.gov (United States)

    Andreh, Angga Muhamad; Subiyanto, Sunardiyo, Said

    2017-01-01

    Development of non-linear loading in the application of industry and distribution system and also harmonic compensation becomes important. Harmonic pollution is an urgent problem in increasing power quality. The main contribution of the study is the modeling approach used to design a shunt active filter and the application of the cascade multilevel inverter topology to improve the power quality of electrical energy. In this study, shunt active filter was aimed to eliminate dominant harmonic component by injecting opposite currents with the harmonic component system. The active filter was designed by shunt configuration with cascaded multilevel inverter method controlled by PID controller and SPWM. With this shunt active filter, the harmonic current can be reduced so that the current wave pattern of the source is approximately sinusoidal. Design and simulation were conducted by using Power Simulator (PSIM) software. Shunt active filter performance experiment was conducted on the IEEE four bus test system. The result of shunt active filter installation on the system (IEEE four bus) could reduce THD current from 28.68% to 3.09%. With this result, the active filter can be applied as an effective method to reduce harmonics.

  14. RA Reactor

    International Nuclear Information System (INIS)

    1978-02-01

    In addition to basic characteristics of the RA reactor, organizational scheme and financial incentives, this document covers describes the state of the reactor components after 18 years of operation, problems concerned with obtaining the licence for operation with 80% fuel, problems of spent fuel storage in the storage pool of the reactor building and the need for renewal of reactor equipment, first of all instrumentation [sr

  15. Multiregion reactors

    International Nuclear Information System (INIS)

    Moura Neto, C. de; Nair, R.P.K.

    1979-08-01

    The study of reflected reactors can be done employing the multigroup diffusion method. The neutron conservation equations, inside the intervals, can be written by fluxes and group constants. A reflected reactor (one and two groups) for a slab geometry is studied, aplying the continuity of flux and current in the interface. At the end, the appropriated solutions for a infinite cylindrical reactor and for a spherical reactor are presented. (Author) [pt

  16. Recycling systems for BWR type reactors

    International Nuclear Information System (INIS)

    Takagi, Akio; Yamamoto, Fumiaki; Fukumoto, Ryuji.

    1986-01-01

    Purpose: To stabilize the coolant flowing characteristics and reactor core reactivity. Constitution: The recycling system in a BWR type reactor comprises a recycling pump disposed to the outside of a reactor pressure vessel, a ring header connected to the recycling pump through main pipe ways, and a plurality of pipes branched from and connected with the ring header and connected to a plurality of jet pumps within the pressure vessel. Then, by making the diameter for the pipeways of each of the branched pipes different from each other, the effective cross-sectional area is varied to thereby average the coolant flow rate supplied to each of the jet pumps. (Seki, T.)

  17. Reactor refueling machine simulator

    International Nuclear Information System (INIS)

    Rohosky, T.L.; Swidwa, K.J.

    1987-01-01

    This patent describes in combination: a nuclear reactor; a refueling machine having a bridge, trolley and hoist each driven by a separate motor having feedback means for generating a feedback signal indicative of movement thereof. The motors are operable to position the refueling machine over the nuclear reactor for refueling the same. The refueling machine also has a removable control console including means for selectively generating separate motor signals for operating the bridge, trolley and hoist motors and for processing the feedback signals to generate an indication of the positions thereof, separate output leads connecting each of the motor signals to the respective refueling machine motor, and separate input leads for connecting each of the feedback means to the console; and a portable simulator unit comprising: a single simulator motor; a single simulator feedback signal generator connected to the simulator motor for generating a simulator feedback signal in response to operation of the simulator motor; means for selectively connecting the output leads of the console to the simulator unit in place of the refueling machine motors, and for connecting the console input leads to the simulator unit in place of the refueling machine motor feedback means; and means for driving the single simulator motor in response to any of the bridge, trolley or hoist motor signals generated by the console and means for applying the simulator feedback signal to the console input lead associated with the motor signal being generated by the control console

  18. Nuclear reactor

    International Nuclear Information System (INIS)

    Hattori, Sadao; Sato, Morihiko.

    1994-01-01

    Liquid metals such as liquid metal sodium are filled in a reactor container as primary coolants. A plurality of reactor core containers are disposed in a row in the circumferential direction along with the inner circumferential wall of the reactor container. One or a plurality of intermediate coolers are disposed at the inside of an annular row of the reactor core containers. A reactor core constituted with fuel rods and control rods (module reactor core) is contained at the inside of each of the reactor core containers. Each of the intermediate coolers comprises a cylindrical intermediate cooling vessels. The intermediate cooling vessel comprises an intermediate heat exchanger for heat exchange of primary coolants and secondary coolants and recycling pumps for compulsorily recycling primary coolants at the inside thereof. Since a plurality of reactor core containers are thus assembled, a great reactor power can be attained. Further, the module reactor core contained in one reactor core vessel may be small sized, to facilitate the control for the reactor core operation. (I.N.)

  19. Prenatal surgery for myelomeningocele and the need for cerebrospinal fluid shunt placement

    Science.gov (United States)

    Tulipan, Noel; Wellons, John C.; Thom, Elizabeth A.; Gupta, Nalin; Sutton, Leslie N.; Burrows, Pamela K.; Farmer, Diana; Walsh, William; Johnson, Mark P.; Rand, Larry; Tolivaisa, Susan; D’Alton, Mary E.; Adzick, N. Scott

    2016-01-01

    Object The Management of Myelomeningocele Study (MOMS) was a multicenter randomized trial comparing the safety and efficacy of prenatal and postnatal closure of myelomeningocele. The trial was stopped early because of the demonstrated efficacy of prenatal surgery, and outcomes on 158 of 183 pregnancies were reported. Here, the authors update the 1-year outcomes for the complete trial, analyze the primary and related outcomes, and evaluate whether specific prerandomization risk factors are associated with prenatal surgery benefit. Methods The primary outcome was a composite of fetal loss or any of the following: infant death, CSF shunt placement, or meeting the prespecified criteria for shunt placement. Primary outcome, actual shunt placement, and shunt revision rates for prenatal versus postnatal repair were compared. The shunt criteria were reassessed to determine which were most concordant with practice, and a new composite outcome was created from the primary outcome by replacing the original criteria for CSF shunt placement with the revised criteria. The authors used logistic regression to estimate whether there were interactions between the type of surgery and known prenatal risk factors (lesion level, gestational age, degree of hindbrain herniation, and ventricle size) for shunt placement, and to determine which factors were associated with shunting among those infants who underwent prenatal surgery. Results Ninety-one women were randomized to prenatal surgery and 92 to postnatal repair. The primary outcome occurred in 73% of infants in the prenatal surgery group and in 98% in the postnatal group (p < 0.0001). Actual rates of shunt placement were only 44% and 84% in the 2 groups, respectively (p < 0.0001). The authors revised the most commonly met criterion to require overt clinical signs of increased intracranial pressure, defined as split sutures, bulging fontanelle, or sunsetting eyes, in addition to increasing head circumference or hydrocephalus. Using

  20. Gendered Connections

    DEFF Research Database (Denmark)

    Jensen, Steffen Bo

    2009-01-01

    This article explores the gendered nature of urban politics in Cape Town by focusing on a group of female, township politicians. Employing the Deleuzian concept of `wild connectivity', it argues that these politically entrepreneurial women were able to negotiate a highly volatile urban landscape...... by drawing on and operationalizing violent, male networks — from struggle activists' networks, to vigilante groups and gangs, to the police. The fact that they were women helped them to tap into and exploit these networks. At the same time, they were restricted by their sex, as their ability to navigate...... space also drew on quite traditional notions of female respectability. Furthermore, the article argues, the form of wild connectivity to an extent was a function of the political transition, which destabilized formal structures of gendered authority. It remains a question whether this form...