WorldWideScience

Sample records for conformal radiotherapy treatment

  1. Conformal Radiotherapy: Physics, Treatment Planning and Verification. Proceedings book

    Energy Technology Data Exchange (ETDEWEB)

    De Wagter, C [ed.

    1995-12-01

    The goal of conformal radiotherapy is to establish radiation dose distributions that conform tightly to the target volume in view of limiting radiation to normal tissues. Conformal radiotherapy significantly improves both local control and palliation and thus contributes to increase survival and to improve the quality of life. The subjects covered by the symposium include : (1) conformal radiotherapy and multi-leaf collimation; (2) three dimensional imaging; (3) treatment simulation, planning and optimization; (4) quality assurance; and (5) dosimetry. The book of proceedings contains the abstracts of the invited lectures, papers and poster presentations as well as the full papers of these contributions.

  2. Conformal Radiotherapy: Physics, Treatment Planning and Verification. Proceedings book

    International Nuclear Information System (INIS)

    De Wagter, C.

    1995-12-01

    The goal of conformal radiotherapy is to establish radiation dose distributions that conform tightly to the target volume in view of limiting radiation to normal tissues. Conformal radiotherapy significantly improves both local control and palliation and thus contributes to increase survival and to improve the quality of life. The subjects covered by the symposium include : (1) conformal radiotherapy and multi-leaf collimation; (2) three dimensional imaging; (3) treatment simulation, planning and optimization; (4) quality assurance; and (5) dosimetry. The book of proceedings contains the abstracts of the invited lectures, papers and poster presentations as well as the full papers of these contributions

  3. Conformation radiotherapy and conformal radiotherapy

    International Nuclear Information System (INIS)

    Morita, Kozo

    1999-01-01

    In order to coincide the high dose region to the target volume, the 'Conformation Radiotherapy Technique' using the multileaf collimator and the device for 'hollow-out technique' was developed by Prof. S. Takahashi in 1960. This technique can be classified a type of 2D-dynamic conformal RT techniques. By the clinical application of this technique, the late complications of the lens, the intestine and the urinary bladder after radiotherapy for the maxillary cancer and the cervical cancer decreased. Since 1980's the exact position and shape of the tumor and the surrounding normal tissues can be easily obtained by the tremendous development of the CT/MRI imaging technique. As a result, various kinds of new conformal techniques such as the 3D-CRT, the dose intensity modulation, the tomotherapy have been developed since the beginning of 1990'. Several 'dose escalation study with 2D-/3D conformal RT' is now under way to improve the treatment results. (author)

  4. Conformal three dimensional radiotherapy treatment planning in Lund

    Energy Technology Data Exchange (ETDEWEB)

    Knoos, T; Nilsson, P [Lund Univ. (Sweden). Dept. of Radiation Physics; Anders, A [Lund Univ. (Sweden). Dept. of Oncology

    1995-12-01

    The use of conformal therapy is based on 3-dimensional treatment planning as well as on methods and routines for 3-dimensional patient mapping, 3-dimensional virtual simulation and others. The management of patients at the Radiotherapy Department at the University Hospital in Lund (Sweden) is discussed. About 2100 new patients are annually treated with external radiotherapy using seven linear accelerators. Three of the accelerators have dual photon energies and electron treatment facilities. A multi-leaf collimator as well as an electronic portal imaging device are available on one machine. Two simulators and an in-house CT-scanner are used for treatment planning. From 1988 to 1992 Scandiplan (Umplan) was used. Since 1992, the treatment planning system is TMS (HELAX AB, Sweden), which is based on the pencil beam algorithm of Ahnesjo. The calculations use patient modulated accelerator specific energy fluence spectra which are compiled with pencil beams from Monte Carlo generated energy absorption kernels. Heterogeneity corrections are performed with results close to conventional algorithms. Irregular fields, either from standard or individual blocks and from multi-leaf collimators are handled by the treatment planning system. The field shape is determined conveniently using the beam`s eye view. The final field shape is exported electronically to either the block cutting machine or the multileaf collimator control computer. All patient fields are checked against the beam`s eye view during simulation using manual methods. Treatment verification is performed by portal films and in vivo dosimetry with silicon diodes or TL-dosimetry. Up to now, approximately 4400 patients have received a highly individualized 3-dimensional conformal treatment.

  5. Conformal three dimensional radiotherapy treatment planning in Lund

    International Nuclear Information System (INIS)

    Knoos, T.; Nilsson, P.; Anders, A.

    1995-01-01

    The use of conformal therapy is based on 3-dimensional treatment planning as well as on methods and routines for 3-dimensional patient mapping, 3-dimensional virtual simulation and others. The management of patients at the Radiotherapy Department at the University Hospital in Lund (Sweden) is discussed. About 2100 new patients are annually treated with external radiotherapy using seven linear accelerators. Three of the accelerators have dual photon energies and electron treatment facilities. A multi-leaf collimator as well as an electronic portal imaging device are available on one machine. Two simulators and an in-house CT-scanner are used for treatment planning. From 1988 to 1992 Scandiplan (Umplan) was used. Since 1992, the treatment planning system is TMS (HELAX AB, Sweden), which is based on the pencil beam algorithm of Ahnesjo. The calculations use patient modulated accelerator specific energy fluence spectra which are compiled with pencil beams from Monte Carlo generated energy absorption kernels. Heterogeneity corrections are performed with results close to conventional algorithms. Irregular fields, either from standard or individual blocks and from multi-leaf collimators are handled by the treatment planning system. The field shape is determined conveniently using the beam's eye view. The final field shape is exported electronically to either the block cutting machine or the multileaf collimator control computer. All patient fields are checked against the beam's eye view during simulation using manual methods. Treatment verification is performed by portal films and in vivo dosimetry with silicon diodes or TL-dosimetry. Up to now, approximately 4400 patients have received a highly individualized 3-dimensional conformal treatment

  6. Conformal Radiotherapy in the Treatment of Advanced Juvenile Nasopharyngeal Angiofibroma With Intracranial Extension: An Institutional Experience

    International Nuclear Information System (INIS)

    Chakraborty, Santam; Ghoshal, Sushmita; Patil, Vijay Maruti; Oinam, Arun Singh; Sharma, Suresh C.

    2011-01-01

    Purpose: To describe the results of conformal radiotherapy in advanced juvenile nasopharyngeal angiofibroma in a tertiary care institution. Methods and Materials: Retrospective chart review was conducted for 8 patients treated with conformal radiotherapy between 2006 and 2009. The median follow-up was 17 months. All patients had Stage IIIB disease with intracranial extension. Radiotherapy was considered as treatment because patients were deemed inoperable owing to extensive intracranial/intraorbital extension or proximity to optic nerve. All but 1 patient were treated with intensity-modulated radiotherapy using seven coplanar fields. Median (range) dose prescribed was 39.6 (30-46) Gy. Actuarial analysis of local control and descriptive analysis of toxicity profile was conducted. Results: Despite the large and complex target volume (median planning target volume, 292 cm 3 ), intensity-modulated radiotherapy achieved conformal dose distributions (median van't Reit index, 0.66). Significant sparing of the surrounding organs at risk was obtained. No significant Grade 3/4 toxicities were experienced during or after treatment. Actual local control at 2 years was 87.5%. One patient died 1 month after radiotherapy secondary to massive epistaxis. The remaining 7 patients had progressive resolution of disease and were symptom-free at last follow-up. Persistent rhinitis was the only significant toxicity, seen in 1 patient. Conclusions: Conformal radiotherapy results in good local control with minimal acute and late side effects in juvenile nasopharyngeal angiofibromas, even in the presence of advanced disease.

  7. Results of different modes conformal radiotherapy in treatment of cervical cancer

    International Nuclear Information System (INIS)

    Baranovs'ka, L.M.; Yivankova, V.S.; Khrulenko, T.V.; Skomorokhova, T.V.; Gorelyina, G.L.

    2017-01-01

    Development of techniques for cytotoxic treatment applying different modes of conformal radiotherapy, brachytherapy and high-energy (high dose rate - HDR) is one of the promising areas of optimization and efficiency of conservative treatment of patients with regional forms of cervical cancer. At Radiation Oncology Department, National Cancer Institute, 89 patients with stage 2b-3b cervical cancer, aged 29 to 70, underwent examination and combined radiotherapy course. The patients were divided into 2 main groups (56 patients) depending on the mode of developed conformal radiation therapy, and a control group made up by 33 patients (classic, default conformal radiotherapy). Results. Along with external beam radiotherapy, the patients of Group 2 were provided with conformal radiotherapy carried out by means of the linear accelerator of electrons in the mode of enhanced multi fractionation of irradiation dose applied to the small pelvis area (tumor and lymph efflux channels) with the single tumor dose 1.3 Gy twice per day once 4-6 hours up to the total radiation dose of 45 Gy applied to the small pelvis lymph nodes. The patients of Group 1 and the ones of the control group underwent conformal radiotherapy in the mode of standard fractionation applied to the small pelvis area with the single tumor dose of 1.8 Gy up to the total radiation dose of 45 Gy. Conformal radiotherapy was carried out for the patients of Group 1 associated with chemoradiomodifiers (tegafur, cisplatin). At the stage 2 of combined radiotherapy course, all patients underwent HDR brachytherapy via Co60 source in the mode of the single tumor dose of 5 Gy at point A up to the total radiation dose of 35-40 Gy. Therefore, employing accelerated mode of multifractiation in conformal radiotherapy of patients with regional cervical cancer makes it possible to enhance canrcinocidal irradiation doses applied to a tumor, and an interval between radiotherapy fractions provides conditions for initiation of

  8. Effects of three-dimensional conformal radiotherapy, indensity modulated radiotherapy, and conventional radiotherapy ON treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Jian-Jun Han

    2016-07-01

    Full Text Available Objective: To compare the irradiation volume, short-term and long-term efficacy of conventional radiotherapy (CR, three-dimensional conformal radiotherapy (3D-CRT, and indensity modulated radiotherapy (IMRT in the treatment of esophageal cancer. Methods: A retrospective analysis method was adopted. The patients were divided into CR group (n=42, 3D-CRT group (n=45, and IMRT group (n=40. A follow-up visit was paid to collect the short-term and long-term efficacy, and the occurrence of adverse reactions. The gross tumor voluem (GTV, clinical target volume (CTV, planning target volume (PTV, and irradiation volume of organs (bilateral lungs, spinal cord, and heart at risk (OAR in the three groups were compared. Results: It was found by target volume comparison that the mean values of GTV, CTV, and PTV in the three groups were significantly increased (P0.05. The occurrence rate of adverse reactions in 3D-CRT group and IMRT group was significantly lower than that in CR group (P0.05. The difference of 1-year survival rate among the three groups was not statistically significant (P=0.144, but 3-year and 5-year survival rates in 3D-CRT group and IMRT group were significantly higher than those in CR group (P<0.05. Conclusions: 3D-CRT and IMRT can significantly enhance the short-term and long-term efficacy for esophageal cancer patients, and alleviate the radioactive damage; therefore, they are deserved to be widely recommended in the clinic.

  9. A computer-controlled conformal radiotherapy system. III: graphical simulation and monitoring of treatment delivery

    International Nuclear Information System (INIS)

    Kessler, Marc L.; McShan, Daniel L.; Fraass, Benedick A.

    1995-01-01

    Purpose: Safe and efficient delivery of radiotherapy using computer-controlled machines requires new procedures to design and verify the actual delivery of these treatments. Graphical simulation and monitoring techniques for treatment delivery have been developed for this purpose. Methods and Materials: A graphics-based simulator of the treatment machine and a set of procedures for creating and manipulating treatment delivery scripts are used to simulate machine motions, detect collisions, and monitor machine positions during treatment. The treatment delivery simulator is composed of four components: a three-dimensional dynamic model of the treatment machine; a motion simulation and collision detection algorithm, user-interface widgets that mimic the treatment machine's control and readout devices; and an icon-based interface for creating and manipulating treatment delivery scripts. These components are used in a stand-alone fashion for interactive treatment delivery planning and integrated with a machine control system for treatment implementation and monitoring. Results: A graphics-based treatment delivery simulator and a set of procedures for planning and monitoring computer-controlled treatment delivery have been developed and implemented as part of a comprehensive computer-controlled conformal radiotherapy system. To date, these techniques have been used to design and help monitor computer-controlled treatments on a radiotherapy machine for more than 200 patients. Examples using these techniques for treatment delivery planning and on-line monitoring of machine motions during therapy are described. Conclusion: A system that provides interactive graphics-based tools for defining the sequence of machine motions, simulating treatment delivery including collision detection, and presenting the therapists with continual visual feedback from the treatment machine has been successfully implemented for routine clinical use as part of an overall system for computer

  10. Comparison of Optimised Treatment Plans for Radiosurgery and Conformal Radiotherapy

    National Research Council Canada - National Science Library

    Kulik, C

    2001-01-01

    ..., it is interesting to compare the different techniques to evaluate their effectiveness, This comparison involves 8 clinical cases, For each treatment modality, we compare indexes defined in the international...

  11. Conformal radiotherapy: principles and classification

    International Nuclear Information System (INIS)

    Rosenwald, J.C.; Gaboriaud, G.; Pontvert, D.

    1999-01-01

    'Conformal radiotherapy' is the name fixed by usage and given to a new form of radiotherapy resulting from the technological improvements observed during the last ten years. While this terminology is now widely used, no precise definition can be found in the literature. Conformal radiotherapy refers to an approach in which the dose distribution is more closely 'conformed' or adapted to the actual shape of the target volume. However, the achievement of a consensus on a more specific definition is hampered by various difficulties, namely in characterizing the degree of 'conformality'. We have therefore suggested a classification scheme be established on the basis of the tools and the procedures actually used for all steps of the process, i.e., from prescription to treatment completion. Our classification consists of four levels: schematically, at level 0, there is no conformation (rectangular fields); at level 1, a simple conformation takes place, on the basis of conventional 2D imaging; at level 2, a 3D reconstruction of the structures is used for a more accurate conformation; and level 3 includes research and advanced dynamic techniques. We have used our personal experience, contacts with colleagues and data from the literature to analyze all the steps of the planning process, and to define the tools and procedures relevant to a given level. The corresponding tables have been discussed and approved at the European level within the Dynarad concerted action. It is proposed that the term 'conformal radiotherapy' be restricted to procedures where all steps are at least at level 2. (author)

  12. Localized field conformation radiotherapy combined with endocrine therapy for the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Karasawa, Katsuyuki; Kaizu, Toshihide; Kurosaki, Hiromasa; Tanaka, Yoshiaki

    1999-01-01

    To improve the quality of life (QOL) of the patients with prostate cancer, we limit the radiotherapy target volume to the prostate and seminal vesicles while using endocrine therapy towards the disease outside the target volume. Radiotherapy technique was rotation conformation technique with computer-controlled multileaf collimators to the total doses of up to 66-70 Gy. Among 145 evaluable cases with the median age of 74, overall and cause-specific 5-year survival rates were 59.3% and 84.1%, respectively, and the relative survival rate of the Stage A-C cases was 100%. The two thirds (33/50) of the deaths were not of prostate cancer. The rate of severe complication was 1.4%. As for QOL, the rate of impotence was 90%, however, the patients' overall satisfaction towards the treatment was 90%. From this analysis, this combined treatment seems beneficial in the treatment of prostate cancer. (author)

  13. Conformal radiotherapy: a glossary

    International Nuclear Information System (INIS)

    Dubray, B.; Giraud, P.; Beaudre, A.

    1999-01-01

    Most of the concepts and terms related to conformal radiotherapy were produced by English-speaking authors and eventually validated by international groups of experts, whose working language was also English. Therefore, a significant part of this literature is poorly accessible to the French-speaking radiation oncology community. The present paper gathers the 'official' definitions already published in French, along with propositions for the remaining terms which should be submitted to a more formal and representative validation process. (author)

  14. Comparison between conventional and three-dimensional conformal treatment planning for radiotherapy of cerebral tumors

    International Nuclear Information System (INIS)

    Caudrelier, J.M.; Auliard, A.; Sarrazin, T.; Gibon, D.; Coche-Dequeant, B.; Castelain, B.

    2001-01-01

    Comparison between conventional and three-dimensional conformal treatment planning for radiotherapy of cerebral tumors. Purpose. - We prospectively compared a conventional treatment planning (PT2D) and 3-dimensional conformal treatment planning (PT3D) for radiotherapy of cerebral tumours. Patients and methods.- Patients treated between 1/10/98 and 1/4/99 by irradiation for cerebral tumours were analysed. For each case, we planned PT2D using conventional orthogonal x-ray films, and afterward, PT3D using CT scan. Gross tumor volume, planning target volume and normal tissue volumes were defined. Dose was prescribed according to report 50 of the International Commission on Radiation Units and Measurements (ICRU). We compared surfaces of sagittal view targets defined on PT2D and PT3D and called them S2D and S3D, respectively. Irradiated volumes by 90% isodoses (VE-90%) and normal tissue volumes irradiated by 20, 50, 90% isodoses were calculated and compared using Student's paired t-test. Results. -There was a concordance of 84% of target surfaces defined on PT2D and PT3D. Percentages of target surface under- or-over defined by PT2D were 16 and 13% respectively. VE-90% was decreased by 15% (p = 0.07) with PT3D. Normal brain volume irradiated by 90% isodose was decreased by 27% with PT3D (p = 0.04). Conclusion.- For radiotherapy of cerebral tumors using only coplanar beams, PT3D leads to a reduction of normal brain tissue irradiated. We recommend PT3D for radiotherapy of cerebral tumors, particularly for low-grade or benign tumors (meningiomas, neuromas, etc.). (authors)

  15. CONSERVATIVE TREATMENT IN LOCALLY AND LOCALLY-ADVANCED PROSTATE CANCER USING CONFORMAL RADIOTHERAPY

    Directory of Open Access Journals (Sweden)

    Tkachev Sergey Ivanovich

    2013-01-01

    Full Text Available The combination of androgen deprivation and radiotherapy increase the probability of diseases full regresses and survival rate. Modern technical and technological opportunities of 3D CRT allow to increase total dose to prostate up to 72-76Gy vs. radiotherapy of 66-70Gy. In this study we compare the rates of post radiation toxicity and the efficiency of treatment for the patients receiving conventional radiotherapy and 3D CRT. The use of 3D CRT has not only result to increase of 10-years recurrence free survival rate from 74% (I grope to 86,5% (II grope, р=0,01, but also to increase of 10-years overall survival, 70% versus 78,4% (р=0,04. The proposed version of conformal 3D CRT radiation therapy made ​​it possible compared to conventional 2D RT radiation therapy by increasing SOD radiation to the tumor, accuracy and compliance with the quality assurance of radiation therapy significantly reduce rates of recurrence and significantly increase the performance of 10-year overall and disease-free survival.

  16. Intensity modulated conformal radiotherapy

    International Nuclear Information System (INIS)

    Noel, Georges; Moty-Monnereau, Celine; Meyer, Aurelia; David, Pauline; Pages, Frederique; Muller, Felix; Lee-Robin, Sun Hae; David, Denis Jean

    2006-12-01

    This publication reports the assessment of intensity-modulated conformal radiotherapy (IMCR). This assessment is based on a literature survey which focussed on indications, efficiency and safety on the short term, on the risk of radio-induced cancer on the long term, on the role in the therapeutic strategy, on the conditions of execution, on the impact on morbidity-mortality and life quality, on the impact on the health system and on public health policies and program. This assessment is also based on the opinion of a group of experts regarding the technical benefit of IMCR, its indications depending on the cancer type, safety in terms of radio-induced cancers, and conditions of execution. Before this assessment, the report thus indicates indications for which the use of IMCR can be considered as sufficient or not determined. It also proposes a technical description of IMCR and helical tomo-therapy, discusses the use of this technique for various pathologies or tumours, analyses the present situation of care in France, and comments the identification of this technique in foreign classifications

  17. Treatment planning evaluation of non-coplanar techniques for conformal radiotherapy of the prostate

    International Nuclear Information System (INIS)

    Bedford, James L.; Henrys, Anthony J.; Dearnaley, David P.; Khoo, Vincent S.

    2005-01-01

    Background and purpose: To evaluate the benefit of using non-coplanar treatment plans for irradiation of two different clinical treatment volumes: prostate only (PO) and the prostate plus seminal vesicles (PSV). Material and methods: An inverse planning algorithm was used to produce three-field, four-field, five-field and six-field non-coplanar treatment plans without intensity-modulation in ten patients. These were compared against a three-field coplanar plan. A dose of 74 Gy was prescribed to the isocentre. Plans were compared using the minimum dose to the planning target volume (PTV), maximum dose to the small bowel, and irradiated volumes of rectum, bladder and femoral head. Biological indices were also evaluated. Results: For the PO group, volume of rectum irradiated to 60 Gy (V 60 ) was 22.5±3.7% for the coplanar plan, and 21.5±5.3% for the five-field non-coplanar plan, which was the most beneficial (p=0.3). For the PSV group, the five-field non-coplanar plan was again the most beneficial. Rectal V 60 was in this case reduced from 41.5±10.4% for the coplanar plan to 35.2±9.3% for the non-coplanar plan (p=0.02). Conclusions: The use of non-coplanar beams in conformal prostate radiotherapy provides a small increase in rectal sparing, more significantly with PSV volumes than for PO volumes

  18. Acute toxicity in pelvic radiotherapy; a randomised trial of conformal versus conventional treatment

    International Nuclear Information System (INIS)

    Tait, Diana M.; Nahum, Alan E.; Meyer, Lesley C.; Law, Matthew; Dearnaley, David P.; Horwich, Alan; Mayles, W. Philip; Yarnold, John R.

    1997-01-01

    Background: A prospective, randomized clinical trial to assess the effect of reducing the volume of irradiated normal tissue on acute reactions in pelvic radiotherapy accrued 266 evaluable patients between 1988 and 1993. Purpose: This is the definitive analysis to assess the differences between the conformal and conventional arms of the trial. Materials and methods: In both arms, patients were treated with 6 MV X-rays using a 3-field technique (in all but 5 cases) consisting of an anterior and two wedged lateral or posterior oblique fields; in the conventional arm, rectangular fields were employed, whereas in the conformal arm, the fields were shaped with customized blocks drawn according to the beam's-eye-view of the target volume. The most common dosage was 65 Gy in 2-Gy fractions 5 times a week, although a subgroup (of ca. bladder patients) were treated with 30-36 Gy in once-a-week 6 Gy fractions. Each patient completed a comprehensive acute toxicity scoring questionnaire concentrating on bowel and bladder problems, tiredness and nausea, before the start of treatment, weekly during and for 3 weeks after the end of treatment and then monthly for a further 2 months. Compliance was excellent. Results: There were no differences between the patients in the two arms with respect to age, gender, tumour type (52% prostate, 41% bladder, 5% rectum, 2% other) fractionation/dosage, anterior field size, weight, or baseline symptoms. Substantial differences in normal-tissue volumes (rectum, bladder, etc.) were achieved: median high-dose volume (HDV) of 689 cm 3 for the conformal technique versus 792 cm 3 for the conventional. A clear pattern of an increase in symptoms during RT, followed by a decrease after RT, was observed for the patient group as a whole. However, a very extensive analysis has not revealed any (statistically) significant differences between the two arms in level of symptoms, nor in medication prescribed. The disparity between our findings and those of other

  19. Selection and determination of beam weights based on genetic algorithms for conformal radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Xingen Wu; Zunliang Wang

    2000-01-01

    A genetic algorithm has been used to optimize the selection of beam weights for external beam three-dimensional conformal radiotherapy treatment planning. A fitness function is defined, which includes a difference function to achieve a least-square fit to doses at preselected points in a planning target volume, and a penalty item to constrain the maximum allowable doses delivered to critical organs. Adjustment between the dose uniformity within the target volume and the dose constraint to the critical structures can be achieved by varying the beam weight variables in the fitness function. A floating-point encoding schema and several operators, like uniform crossover, arithmetical crossover, geometrical crossover, Gaussian mutation and uniform mutation, have been used to evolve the population. Three different cases were used to verify the correctness of the algorithm and quality assessment based on dose-volume histograms and three-dimensional dose distributions were given. The results indicate that the genetic algorithm presented here has considerable potential. (author)

  20. Treatment Planning Study to Determine Potential Benefit of Intensity-Modulated Radiotherapy Versus Conformal Radiotherapy for Unresectable Hepatic Malignancies

    International Nuclear Information System (INIS)

    Eccles, Cynthia L.; Bissonnette, Jean-Pierre; Craig, Tim; Taremi, Mojgan; Wu Xia; Dawson, Laura A.

    2008-01-01

    Purpose: To compare intensity-modulated radiotherapy (IMRT) with conformal RT (CRT) for hypofractionated isotoxicity liver RT and explore dose escalation using IMRT for the same/improved nominal risk of liver toxicity in a treatment planning study. Methods and Materials: A total of 26 CRT plans were evaluated. Prescription doses (24-54 Gy within six fractions) were individualized on the basis of the effective liver volume irradiated maintaining ≤5% risk of radiation-induced liver disease. The dose constraints included bowel (0.5 cm 3 ) and stomach (0.5 cm 3 ) to ≤30 Gy, spinal cord to ≤25 Gy, and planning target volume (PTV) to ≤140% of the prescribed dose. Two groups were evaluated: (1) PTV overlapping or directly adjacent to serial functioning normal tissues (n = 14), and (2) the liver as the dose-limiting normal tissue (n = 12). IMRT plans using direct machine parameter optimization maintained the CRT plan beam arrangements, an estimated radiation-induced liver disease risk of 5%, and underwent dose escalation, if all normal tissue constraints were maintained. Results: IMRT improved PTV coverage in 19 of 26 plans (73%). Dose escalation was feasible in 9 cases by an average of 3.8 Gy (range, 0.6-13.2) in six fractions. Three of seven plans without improved PTV coverage had small gross tumor volumes (≤105 cm 3 ) already receiving 54 Gy, the maximal prescription dose allowed. In the remaining cases, the PTV range was 9.6-689 cm 3 ; two had overlapped organs at risk; and one had four targets. IMRT did not improve these plans owing to poor target coverage (n = 2) and nonliver (n = 2) dose limits. Conclusion: Direct machine parameter optimization IMRT improved PTV coverage while maintaining normal tissue tolerances in most CRT liver plans. Dose escalation was possible in a minority of patients

  1. 3D-conformal radiotherapy treatment of high grade gliomas of malignancy

    International Nuclear Information System (INIS)

    Chon Rivas, Ivonne; Chi Ramirez, Daysi; Alert Silva, Jose; Roca Muchuli, Carlos; Leon Gonzalez, Roberto; Perez Penna, Lourdes

    2009-01-01

    Patients diagnosed with high grade gliomas of malignancy (A), have a high mortality rate, about 10% achieve survivals than one year due to poor local control resulting from the inability of high doses of radiation to tumor volume by dose-limiting provided by healthy peritumoral tissues and structures. 3D conformal radiotherapy (RT-3DC) achieves effective tumoricidal high doses with high precision on the tumor with minimal involvement of critical structures near the tumor target volume. From 2005 until 2008 at INOR, a total of 23 patients with histologically confirmed supratentorial gliomas location, histological subtypes of anaplastic astrocytoma (AA) in 8 patients (35%) and Glioblastoma Multiforme (GBM) in 15 patients (65%), aged between 18 and 65, Karnofski scale of 70 or more and total previous surgical resection in 10 patients (43%) or partial in 13 (57%) were included prospectively in this study. The total tumor dose of 66-70 Gy was prescribed with a daily fractionation of 1.8 Gy. All patients underwent CT images (CT) and MRI (MRI) cranial volumes were defined treatment planning according to the concepts of ICRU 50 and 62 with precise immobilization of the head by thermo deformed mask, CT 3mm cuts planning system and 3D treatment planning. Median survival was better in patients younger than 55 years, with high rates of Karnofski, histology of AA and higher percentage of surgical resection. Median survival (Kaplan-Meier method) obtained was 16 months. Survival at 1 and 2 years was 51% and 28% respectively. The RT-3DC can administer higher doses on the tumor with peritumoral healthy protection structures in selected patients with a diagnosis of AA or GBM, increasing local control and potentially overall survival without exacerbating toxicity, thus demonstrating the dose- response of malignant brain tumors. (Author)

  2. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Kubo, H. Dale; Wilder, Richard B.; Pappas, Conrad T.E.

    1999-01-01

    Purpose: The authors undertook a study to analyze the impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. Methods and Materials: Twelve cases involving primary brain tumors, metastases, or arteriovenous malformations that had been planned with BrainLAB's conventional circular collimator-based radiosurgery system were re-planned using a β-version of BrainLAB's treatment planning software that is compatible with MRC Systems' and BrainLAB's micro-multileaf collimators. These collimators have a minimum leaf width of 1.7 mm and 3.0 mm, respectively, at isocenter. The clinical target volumes ranged from 2.7-26.1 cc and the number of static fields ranged from 3-5. In addition, for 4 prostate cancer cases, 2 separate clinical target volumes were planned using MRC Systems' and BrainLAB's micro-multileaf collimators and Varian's multileaf collimator: the smaller clinical target volume consisted of the prostate gland and the larger clinical target volume consisted of the prostate and seminal vesicles. For the prostate cancer cases, treatment plans were generated using either 6 or 7 static fields. A 'PITV ratio', which the Radiation Therapy Oncology Group defines as the volume encompassed by the prescription isodose surface divided by the clinical target volume, was used as a measure of the quality of treatment plans (a PITV ratio of 1.0-2.0 is desirable). Bladder and rectal volumes encompassed by the prescription isodose surface, isodose distributions and dose volume histograms were also analyzed for the prostate cancer patients. Results: In 75% of the cases treated with radiosurgery, a PITV ratio between 1.0-2.0 could be achieved using a micro-multileaf collimator with a leaf width of 1.7-3.0 mm at isocenter and 3-5 static fields. When the clinical target volume consisted of the prostate gland, the micro-multileaf collimator with a minimum leaf width of 3.0 mm allowed one to decrease the median volume of bladder and

  3. Nasopharynx carcinoma treatment: from the conventional radiotherapy to the conformal radiotherapy with intensity modulation; Traitement du carcinome du nasopharynx: de la radiotherapie conventionnelle a la radiotherapie conformationnelle avec modulation d'intensite

    Energy Technology Data Exchange (ETDEWEB)

    Mokaouim, K.; Grehange, G.; Truc, G.; Peingnaux, K.; Martin, E.; Zanetta, S.; Bruchon, Y.; Bonnetain, F.; Maingon, P. [Centre Georges-Francois Leclerc, 21 - Dijon (France)

    2009-10-15

    The objective of this study was to evaluate retrospectively the impact of factors linked to the radiotherapy realisation on the local and locoregional control, the global survival, the survival without disease of patients suffering of naso-pharynx carcinoma. Conclusion: the patients suffering of a nasopharynx carcinoma treated by irradiation associated to chemotherapy have an improved global survival and an improved survival without disease. The conformal radiotherapy with or without modulated intensity reduce the risk of serous otitis, trismus and xerostomia at long term. It seems necessary to realize multi centric studies with a longer period of follow up before asserting the advantages of the I.M.R.T. in comparison to the classical and conformal technique in the treatment of naso-pharynx carcinomas. (N.C.)

  4. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Bora Uysal

    2013-03-01

    Full Text Available Objective: The purpose of this dosimetric study is the targeted dose homogeneity and critical organ dose comparison of 7-field Intensity Modulated Radiotherapy (IMRT and 3-D 4-field conformal radiotherapy. Study Design: Cross sectional study. Material and Methods: Twenty patients with low and moderate risk prostate cancer treated at Gülhane Military Medical School Radiation Oncology Department between January 2009 and December 2009 are included in this study. Two seperate dosimetric plans both for 7-field IMRT and 3D-CRT have been generated for each patient to comparatively evaluate the dosimetric status of both techniques and all the patients received 7-field IMRT. Results: Dose-comparative evaluation of two techniques revealed the superiority of IMRT technique with statistically significantly lower femoral head doses along with reduced critical organ dose-volume parameters of bladder V60 (the volume receiving 60 Gy and rectal V40 (the volume receiving 40 Gy and V60. Conclusion: It can be concluded that IMRT is an effective definitive management tool for prostate cancer with improved critical organ sparing and excellent dose homogenization in target organs of prostate and seminal vesicles.

  5. Conformal radiotherapy in the adjuvant treatment of gastric cancer: Review of 82 cases

    International Nuclear Information System (INIS)

    Kassam, Zahra; Lockwood, Gina; O'Brien, Catherine; Brierley, James; Swallow, Carol; Oza, Amit; Siu, Lillian; Knox, Jennifer J.; Wong, Rebecca; Cummings, Bernard; Kim, John; Moore, Malcolm; Ringash, Jolie

    2006-01-01

    Background: The Intergroup 0116 study showed a survival benefit with adjuvant chemoradiotherapy (CRT) for resected gastric cancer. We report our experience using conformal radiotherapy (RT). Methods and Materials: Eighty-two patients with resected gastric or gastroesophageal junction (GEJ) adenocarcinoma, Stage IB to IV (M0), were treated with 45 Gy in 25 fractions using a 5-field conformal technique. Chemotherapy was in accordance with the Intergroup 0116 study, or infusional 5-fluorouracil and cisplatin in a phase I/II trial. Results: Mean age was 56.4 years. Median follow-up was 22.8 months. Grade 3 or greater acute toxicity (National Cancer Institute Common Terminology Criteria of Adverse Events, version 3.0) was noted in 57% of patients (upper gastrointestinal tract 34%, hematologic 33%). One patient died of neutropenic sepsis. Radiation Therapy Oncology Group Grade 3 late toxicity included esophageal strictures (3 patients) and small bowel obstruction (1 patient). Full course CRT was completed by 67% of patients. Of 26 patients who relapsed, 20 died. Site of first relapse was available on 23 patients: 8 locoregional and distant, 4 locoregional alone, 11 distant alone. Overall and relapse-free survival were 69% and 54% at 3 years. Conclusion: Adjuvant CRT for gastric cancer, even with conformal RT, is associated with significant toxicity. Survival was comparable to that reported in the Intergroup 0116 study

  6. Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Pasciuti, Katia, E-mail: k.pasciuti@virgilio.it [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Kuthpady, Shrinivas [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Anderson, Anne; Best, Bronagh [Department of Radiotherapy Physics, Royal Free Hospital, London (United Kingdom); Waqar, Saleem; Chowdhury, Subhra [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2017-04-01

    To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results. Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.

  7. Gel dosimetry for conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G [Department of Physics of the University and INFN, Milan (Italy)

    2005-07-01

    With the continuum development of conformal radio therapies, aimed at delivering high dose to tumor tissue and low dose to the healthy tissue around, the necessities has appeared of suitable improvement of dosimetry techniques giving the possibility of obtaining dose images to be compared with diagnostic images. Also if wide software has been developed for calculating dose distributions in the fields of various radiotherapy units, experimental verifications are necessary, in particular in the case of complex geometries in conformal radiotherapy. Gel dosimetry is a promising method for imaging the absorbed dose in tissue-equivalent phantoms, with the possibility of 3D reconstruction of the spatial dose distribution, with milli metric resolution. Optical imaging of gel dosimeters, based on visible light absorbance analysis, has shown to be a reliable technique for achieving dose distributions. (Author)

  8. Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system

    International Nuclear Information System (INIS)

    Ding Meisong; Newman, Francis M.S.; Kavanagh, Brian D.; Stuhr, Kelly M.S.; Johnson, Tim K.; Gaspar, Laurie E.

    2006-01-01

    Purpose: To investigate the dosimetric differences among three-dimensional conformal radiotherapy (3D-CRT), dynamic conformal arc therapy (DCAT), and intensity-modulated radiotherapy (IMRT) for brain tumor treatment. Methods and Materials: Fifteen patients treated with Novalis were selected. We performed 3D-CRT, DCAT, and IMRT plans for all patients. The margin for the planning target volume (PTV) was 1 mm, and the specific prescription dose was 90% for all plans. The target coverage at the prescription dose, conformity index (CI), and heterogeneity index were analyzed for all plans. Results: For small tumors (PTV ≤2 cm 3 ), the three dosimetric parameters had approximate values for both 3D-CRT and DCAT plans. The CI for the IMRT plans was high. For medium tumors (PTV >2 to ≤100 cm 3 ), the three plans were competitive with each other. The IMRT plans had a greater CI, better target coverage at the prescription dose, and a better heterogeneity index. For large tumors (PTV >100 cm 3 ), the IMRT plan had good target coverage at the prescription dose and heterogeneity index and approximate CI values as those in the 3D-CRT and DCAT plans. Conclusion: The results of our study have shown that DCAT is suitable for most cases in the treatment of brain tumors. For a small target, 3D-CRT is useful, and IMRT is not recommended. For larger tumors, IMRT is superior to 3D-CRT and very competitive in sparing critical structures, especially for big tumors

  9. Clinical variability of target volume description and treatment plans in conformal radiotherapy in muscle invasive bladder cancer

    International Nuclear Information System (INIS)

    Logue, John P; Sharrock, Carole L; Cowan, Richard A.; Read, Graham; Marrs, Julie; Mott, David

    1996-01-01

    Purpose/Objective: The delineation of tumor and the production of a treatment plan to encompass this is the prime step in radiotherapy planning. Conformal radiotherapy is developing rapidly and although plentiful research has addressed the implementation of the radiotherapy prescription, scant attention has been made to the fundamental step of production, by the clinician, of an appropriate target volume. As part of an ongoing randomized trial of conformal radiotherapy, in bladder cancer, we have therefore assessed the interphysician variability of radiologists and radiation oncologists (RO) in assessing Gross Tumor Volume(GTV) (ICRU 50) and the adherence of the radiation oncologists to the study protocol of producing a Planning Target Volume (PTV). Materials and Methods: Four patients with T3 carcinoma of bladder who had been entered into the trial were identified. The clinical details, MR scans and CT scans were made available. Eight RO and 3 dedicated diagnostic oncology radiologists were invited to directly outline the GTV onto CT images on a planning computer consul. The RO in addition created a PTV following the trial protocol of 15mm margin around the GTV. Three RO sub-specialized in Urological radiotherapy; all RO had completed training. Volumes were produced, for each clinician, and comparison of these volumes and their isocenters were analyzed. In addition the margins allowed were measured and compared. Results: There was a maximum variation ratio (largest to smallest volume outlined) of the GTV in the four cases of 1.74 among radiologists and 3.74 among oncologists. There was a significant difference (p=0.01) in mean GTV between RO and the radiologists. The mean GTV of the RO exceeded the radiologists by a factor of 1.29 with a mean difference of 13.4 cm 3 The between observer variance within speciality comprised only 9.9% of the total variance in the data having accounted for case and observers speciality. The variation ratio in PTV among oncologists

  10. The comparison of 5-field conformal radiotherapy techniques for the treatment of prostate cancer: The best for femoral head sparing

    International Nuclear Information System (INIS)

    Zare, Mahkameh; Lashkari, Marzieh; Ghalehtaki, Reza; Ghasemi, Arash; Dehghan Manshadi, Hamidreza; Mir, Ali; Noorollahi, Somayeh; Alamolhoda, Mahboobeh

    2016-01-01

    External radiotherapy is a standard treatment procedure for localized prostate cancer. Given the relatively high long term survival treatment complications have been brought in center of attention. In this planning study, between 2012 and 2014, CT simulation data of 90 consecutive high-risk prostate cancer patients were collected. In the first phase, all were planned for whole pelvis irradiation up to 46Gy in 23 daily fractions. In the second phase, only the prostate gland was the target of radiation. Next, the subjects were divided randomly into three groups and each received a unique 5field conformal radiation plan including Plan A (Gantry angle: 0, 60, 120, 240, and 300), Plan B (Gantry angles: 0, 90, 120, 240, and 270) and Plan C (Gantry angles: 0, 60, 90, 270, and 300). The total dose was 70Gy. For each patient, the rectum, bladder, and both femoral heads were contoured as the at risk organs (OAR). From dose volume histograms, the proportional dose of PTV V100, the bladder and rectum V80 and V90 and femoral head V50 and V100 were calculated in all subjects and compared across plans. A statistically significant difference in the femoral head V50 and V100 was found between our studied 5field plans so that in Plan A (beam angles: 0, 60, 120, 240 and 300) less dose was received by both heads of femur. This study suggests that 5 field treatment planning including an anterior, two anterior oblique and two posterior oblique portals to be more proper for 3D conformal radiotherapy in order to spare femoral head with acceptable PTV coverage, and bladder and rectal doses.

  11. Clinical Studies on conformal radiotherapy combined with epidermal ...

    African Journals Online (AJOL)

    in second-line treatment of non-small cell lung cancer ... receptor-tyrosine kinase inhibitor (EGFR-TKI) in the second-line treatment of non-small cell ... were divided into two groups: 106 patients were treated with conformal ... Conformal radiotherapy, Targeted therapy, Survival rate .... regression model was used for survival.

  12. Intensity-Modulated Radiotherapy Causes Fewer Side Effects than Three-Dimensional Conformal Radiotherapy When Used in Combination With Brachytherapy for the Treatment of Prostate Cancer

    International Nuclear Information System (INIS)

    Forsythe, Kevin; Blacksburg, Seth; Stone, Nelson; Stock, Richard G.

    2012-01-01

    Purpose: To measure the benefits of intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3D-CRT) when used in combination with brachytherapy for the treatment of prostate cancer. Methods and Materials: We conducted a retrospective review of all patients with localized prostate cancer who received external-beam radiotherapy (EBRT) in combination with brachytherapy with at least 1 year follow-up (n = 812). Combination therapy consisted of 103 Pd or 125 I implant, followed by a course of EBRT. From 1993 to March 2003 521 patients were treated with 3D-CRT, and from April 2003 to March 2009 291 patients were treated with IMRT. Urinary symptoms were prospectively measured with the International Prostate Symptom Score questionnaire with a single quality of life (QOL) question; rectal bleeding was assessed per the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring Schema. The Pearson χ 2 test was used to compare toxicities experienced by patients who were treated with either IMRT or 3D-CRT. Logistic regression analyses were also performed to rule out possible confounding factors. Results: Within the first 3 months after treatment, patients treated with 3D-CRT scored their urinary symptoms as follows: 19% mild, 44% moderate, and 37% severe; patients treated with IMRT scored their urinary symptoms as follows: 36% mild, 47% moderate, and 17% severe (p < 0.001). The 3D-CRT patients rated their QOL as follows: 35% positive, 20% neutral, and 45% negative; IMRT patients rated their QOL as follows: 51% positive, 18% neutral, and 31% negative (p < 0.001). After 1 year of follow-up there was no longer any difference in urinary morbidity between the two groups. Logistic regression confirmed the differences in International Prostate Symptom Score and QOL in the acute setting (p < 0.001 for both). Grade ≥2 rectal bleeding was reported by 11% of 3D-CRT patients and 7

  13. Clinical Applications of 3-D Conformal Radiotherapy

    Science.gov (United States)

    Miralbell, Raymond

    Although a significant improvement in cancer cure (i.e. 20% increment) has been obtained in the last 2-3 decades, 30-40% of patients still fail locally after curative radiotherapy. In order to improve local tumor control rates with radiotherapy high doses to the tumor volume are frequently necessary. Three-dimensional conformal radiation therapy (3-D CRT) is used to denote a spectrum of radiation planning and delivery techniques that rely on three-dimensional imaging to define the target (tumor) and to distinguish it from normal tissues. Modern, high-precision radiotherapy (RT) techniques are needed in order to implement the goal of optimal tumor destruction delivering minimal dose to the non-target normal tissues. A better target definition is nowadays possible with contemporary imaging (computerized tomography, magnetic resonance imaging, and positron emission tomography) and image registration technology. A highly precise dose distributions can be obtained with optimal 3-D CRT treatment delivery techniques such as stereotactic RT, intensity modulated RT (IMRT), or protontherapy (the latter allowing for in-depth conformation). Patient daily set-up repositioning and internal organ immobilization systems are necessary before considering to undertake any of the above mentioned high-precision treatment approaches. Prostate cancer, brain tumors, and base of skull malignancies are among the sites most benefitting of dose escalation approaches. Nevertheless, a significant dose reduction to the normal tissues in the vicinity of the irradiated tumor also achievable with optimal 3-D CRT may also be a major issue in the treatment of pediatric tumors in order to preserve growth, normal development, and to reduce the risk of developing radiation induced diseases such as cancer or endocrinologic disorders.

  14. Film dosimetry in conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Danciu, C; Proimos, B S [Patras Univ. (Greece). Dept. of Medical Physics

    1995-12-01

    Dosimetry, through a film sandwiched in a transverse cross-section of a solid phantom, is a method of choice in Conformal Radiotherapy because: (a) the blackness (density) of the film at each point offers a measure of the total dose received at that point, and (b) the film is easily calibrated by exposing a film strip in the same cross-section, through a stationary field. The film must therefore have the following properties: (a) it must be slow, in order not to be overexposed, even at a therapeutic dose of 200 cGy, and (b) the response of the film (density versus dose curve) must be independent of the photon energy spectrum. A few slow films were compared. It was found that the Kodak X-Omat V for therapy verification was the best choice. To investigate whether the film response was independent of the photon energy, response curves for six depths, starting from the depth of maximum dose to the depth of 25 cm, in solid phantom were derived. The vertical beam was perpendicular to the anterior surface of the phantom, which was at the distance of 100 cm from the source and the field was 15x15 cm at that distance. This procedure was repeated for photon beams emitted by a Cobalt-60 unit, two 6 MV and 15 MV Linear Accelerators, as well as a 45 MV Betatron. For each of those four different beams the film response was the same for all six depths. The results, as shown in the diagrams, are very satisfactory. The response curve under a geometry similar to that actually applied, when the film is irradiated in a transverse cross-section of the phantom, was derived. The horizontal beam was almost parallel (angle of 85) to the plane of the film. The same was repeated with the central ray parallel to the film (angle 90) and at a distance of 1.5 cm from the horizontal film. The field size was again 15x15 at the lateral entrance surface of the beam. The response curves remained the same, as when the beam was perpendicular to the films.

  15. Bladder filling variation during conformal radiotherapy for rectal cancer

    International Nuclear Information System (INIS)

    Sithamparam, S; Ahmad, R; Sabarudin, A; Othman, Z; Ismail, M

    2017-01-01

    Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients. (paper)

  16. Bladder filling variation during conformal radiotherapy for rectal cancer

    Science.gov (United States)

    Sithamparam, S.; Ahmad, R.; Sabarudin, A.; Othman, Z.; Ismail, M.

    2017-05-01

    Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients.

  17. Application of super-omni wedge concept to conformal radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Dai Jianrong; Fu Weihua; Hu Yimin

    2004-01-01

    Objective: To describe a method which can optimize beam weight, wedge angle, and wedge orientation simultaneously by combining the super-omni wedge (SOW) concept with the function of beam weight optimization provided by a commercial treatment planning system. Methods: A five-step procedure including: Step 1. To set up four 60 degree nominal wedged beams for each beam direction with the wedge orientations of 'LEFT', 'IN', 'RIGHT', 'OUT', respectively; Step 2. To define an optimization request, including an optimization goal and constraints. Authors use CMS Focus treatment planning system which allows us to choose 'maximize target dose' or 'minimize critical structure dose' as the optimization goal, and to set minimum target dose, maximum target dose, and maximum average dose of critical structures as constraints. Then the optimization process was launched as step 3; Step 4. To evaluate the plan using isodose distributions and dose-volume histograms. If acceptable, go to Step 5. Otherwise, go back to Step 2 to modify optimization constraints; and Step 5. Transform the SOW beams into the beams of omni wedge so as to reduce the number of to-be-delivered beams. Results: This procedure was found being able to demonstrate successfully in two clinical cases: an esophageal carcinoma and a brain tumor. Compared with manually designed plan, the optimized plan showed better dose homogeneity in the targets and better sparing of the critical structures. Conclusions: This method described is able to optimize beam weights while working with a treatment planning system. Not only does it improve treatment plans' quality, but also shorten the treatment planning process

  18. A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Song, Paul Y.; Washington, Maxine; Vaida, Florin; Hamilton, Russell; Spelbring, Danny; Wyman, Brenda; Harrison, Joanne; Chen, George T. Y.; Vijayakumar, Srinivasan

    1996-01-01

    Purpose: To determine the variability of patient positioning during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer treated with no immobilization or one of four immobilization devices, and to determine the effects of patient body habitus and pelvic circumference on patient movement with each individual immobilization technique. Methods and Materials: To see whether our immobilization techniques have improved day-to-day patient movement, a retrospective analysis was carried out. A total of 62 patients treated at one facility on a single machine with 3D-CRT via a four-field box technique (anterior-posterior and opposed laterals) in the supine position with either no immobilization or one of four immobilization devices. Five groups of patients were compared: (a) group 1-no immobilization; (b) group 2-alpha cradle from the waist to upper thigh; (c) group 3-alpha cradle from waist to below the knees; (d) group 4-styrofoam leg immobilizer (below knees); and (e) group 5-aquaplast cast encompassing the entire abdomen and pelvis to midthigh with alpha cradle immobilization to their lower legs and feet. Prior to starting radiotherapy, portal films of all four treatment fields were obtained 1 day before treatment. Subsequently, portal films were then obtained at least once a week. Portal films were compared with the simulation films and appropriate changes were made and verified on the next day prior to treatment. A deviation of greater than 0.5 cm or greater was considered to be clinically significant in our analysis. We studied the difference among the types of immobilization and no immobilization by looking at the frequency of movements (overall, and on each of the three axes) that a patient had during the course of his treatment. Using a logistic regression model, the probability of overall and individual directional movement for each group was obtained. In addition, the effects of patient body habitus and pelvic circumference on movement were

  19. Conkiss: Conformal Kidneys Sparing 3D Noncoplanar Radiotherapy Treatment for Pancreatic Cancer As an Alternative to IMRT

    International Nuclear Information System (INIS)

    Sebestyen, Zsolt; Kovacs, Peter; Gulyban, Akos; Farkas, Robert; Bellyei, Szabolcs; Liposits, Gabor; Szigeti, Andras; Esik, Olga; Derczy, Katalin; Mangel, Laszlo

    2011-01-01

    When treating pancreatic cancer using standard (ST) 3D conformal radiotherapy (3D-CRT) beam arrangements, the kidneys often receive a higher dose than their probable tolerance limit. Our aim was to elaborate a new planning method that-similarly to IMRT-effectively spares the kidneys without compromising the target coverage. Conformal kidneys sparing (CONKISS) 5-field, noncoplanar plans were compared with ST plans for 23 consecutive patients retrospectively. Optimal beam arrangements were used consisting of a left- and right-wedged beam-pair and an anteroposterior beam inclined in the caudal direction. The wedge direction determination (WEDDE) algorithm was developed to adjust the adequate direction of wedges. The aimed organs at risk (OARs) mean dose limits were: kidney <12 Gy, liver <25 Gy, small bowels <30 Gy, and spinal cord maximum <45 Gy. Conformity and homogeneity indexes with z-test were used to evaluate and compare the different planning approaches. The mean dose to the kidneys decreased significantly (p < 0.05): left kidney 7.7 vs. 10.7 Gy, right kidney 9.1 vs. 11.7 Gy. Meanwhile the mean dose to the liver increased significantly (18.1 vs. 15.0 Gy). The changes in the conformity, homogeneity, and in the doses to other OARs were not significant. The CONKISS method balances the load among the OARs and significantly reduces the dose to the kidneys, without any significant change in the conformity and homogeneity. Using 3D-CRT the CONKISS method can be a smart alternative to IMRT to enhance the possibility of dose escalation.

  20. Clinical Studies on conformal radiotherapy combined with epidermal ...

    African Journals Online (AJOL)

    Purpose: To study the effect of conformal radiotherapy combined with epidermal growth factor receptor-tyrosine kinase inhibitor (EGFR-TKI) in the second-line treatment of non-small cell lung cancer (NSCLC). Methods: A total of 316 patients attending Shanghai Pulmonary Hospital affiliated to Tongji University, were divided ...

  1. A high-precision system for conformal intracranial radiotherapy

    International Nuclear Information System (INIS)

    Tome, Wolfgang A.; Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Li Zuofeng

    2000-01-01

    Purpose: Currently, optimally precise delivery of intracranial radiotherapy is possible with stereotactic radiosurgery and fractionated stereotactic radiotherapy. We report on an optimally precise optically guided system for three-dimensional (3D) conformal radiotherapy using multiple noncoplanar fixed fields. Methods and Materials: The optically guided system detects infrared light emitting diodes (IRLEDs) attached to a custom bite plate linked to the patient's maxillary dentition. The IRLEDs are monitored by a commercially available stereo camera system, which is interfaced to a personal computer. An IRLED reference is established with the patient at the selected stereotactic isocenter, and the computer reports the patient's current position based on the location of the IRLEDs relative to this reference position. Using this readout from the computer, the patient may be dialed directly to the desired position in stereotactic space. The patient is localized on the first day and a reference file is established for 5 different couch positions. The patient's image data are then imported into a commercial convolution-based 3D radiotherapy planning system. The previously established isocenter and couch positions are then used as a template upon which to design a conformal 3D plan with maximum beam separation. Results: The use of the optically guided system in conjunction with noncoplanar radiotherapy treatment planning using fixed fields allows the generation of highly conformal treatment plans that exhibit a high degree of dose homogeneity and a steep dose gradient. To date, this approach has been used to treat 28 patients. Conclusion: Because IRLED technology improves the accuracy of patient localization relative to the linac isocenter and allows real-time monitoring of patient position, one can choose treatment-field margins that only account for beam penumbra and image resolution without adding margin to account for larger and poorly defined setup uncertainty. This

  2. Modification of a three-dimensional treatment planning system for the use of multi-leaf collimators in conformation radiotherapy

    International Nuclear Information System (INIS)

    Boesecke, R.; Becker, G.; Alandt, K.; Pastyr, O.; Doll, J.; Schlegel, W.; Lorenz, W.J.

    1991-01-01

    The multi-leaf collimator of the DKFZ is designed as a low cost add-on device for conventional linear accelerators for radiotherapy. The technical specification of the computer controlled collimator is briefly described . A major limitation in the use of the wide capabilities of multi-leaf collimators in the clinic is still an appropriate treatment planning system. This paper describes treatment planning and dose calculation techniques for multi-leaf collimators and shows examples where the capabilities of the collimators are used extensively. (author). 18 refs.; 8 figs.; 2 tabs

  3. Conformation radiotherapy with eccentric multi-leaves, (1)

    International Nuclear Information System (INIS)

    Obata, Yasunori; Sakuma, Sadayuki.

    1986-01-01

    In order to extend the application of the conformation radiotherapy, the eccentric multi-leaves are equipped with the linear accelerator. The information of the position of the collimators and the dose distribution of the eccentric conformation radiotherapy are calculated by the improved algorism of the treatment planning system. In simple cases, the dose distributions for the distant region from the rotational center are measured and compared with the calculated values. Both distributions are well coincided with the error of about 5 % in the high dose region and 10 % in the low dose region. In eccentric conformation radiotherapy, it is difficult to deliver the planned dose to the lesion. The dose increases with the distance of the target area from the rotational center. And the measured value and the calculated value are well coincided with 1 % error. So after getting the dose ratio of the rotational center to the target area, the calculated dose can be delivered to the rotational center. The advantages of the eccentric conformation radiotherapy are a good coincidence of target area and treated area, a partial shielding and a hollow out technique without absorber. The limitation of the movement of the collimator from center is 5 cm at 1 m SCD. (author)

  4. Dosimetric Comparison of Three-Dimensional Conformal Proton Radiotherapy, Intensity-Modulated Proton Therapy, and Intensity-Modulated Radiotherapy for Treatment of Pediatric Craniopharyngiomas

    Energy Technology Data Exchange (ETDEWEB)

    Boehling, Nicholas S. [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Grosshans, David R., E-mail: dgrossha@mdanderson.org [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Bluett, Jaques B. [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Palmer, Matthew T. [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Song, Xiaofei; Amos, Richard A.; Sahoo, Narayan [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Meyer, Jeffrey J.; Mahajan, Anita; Woo, Shiao Y. [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2012-02-01

    Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV) coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk

  5. The study of treatment value of concurrent chemotherapy for patients with esophageal carcinoma received three-dimensional conformal radiotherapy or intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Wang Lan; Wang Jun; Han Chun; Zhang Jing; Li Xiaoning; Gao Chao

    2011-01-01

    Objective: To observe the acute side effects, local control rate and survival rate of concurrent chemoradiotherapy (CC) and radiotherapy alone (R) for patients with esophageal carcinoma. Methods: From June 2006 to February 2009, 209 patients with esophageal carcinoma were observed, 105 of them were treated with CC. Of all the patients, 117 received three-dimensional conformal radiotherapy, 92 received intensity modulated radiotherapy, the median prescription dose was 60 Gy. The regimen of LFP (5-FU, cisplatin and calcium folinate) was selected for this study, side effects, local control rate and survival rate were observed and subsets analysis were performed. Results: The overall follow-up rate was 99.0%,there were 99 and 44 patients whose follow-up time was more than 2 and 3 years, respectively;for the CC group, the data were 45 and 14, respectively; and for the R group, 54 and 30, respectively. The 1-, 2-, 3-year local control rates of CC group and R group were 88.1%, 69.2%, 66.2% and 81.0%, 64.0%, 54.9% (χ 2 =2.31, P=0.128), respectively. The 1-, 2-, 3-year overall survival rates of CC group and R group were 84.4%, 52.9%, 45.6% and 75.2%, 50.7%, 37.0%(χ 2 =1.57, P=0.210), respectively. Subset analysis indicated that for the patients of N 0 group and whose length of GTV >7 cm, the local control rate of CC was significantly higher than that of radiotherapy alone (χ 2 =5.11, 7.66; P=0.024, 0.006). For N 0 group, the survival rate of CC was higher than that of R alone. (χ 2 =5.07, P=0.024). The incidence of WBC, PLT and HGB reduction for the two groups were 81.9% and 49.0% (χ 2 =36.45, P=0.000), 14.3% and 1.9% (χ 2 =10.54, P=0.006), and 24.8% and 2.9% (χ 2 =22.95, P=0.000), respectively. The incidence of nausea, vomiting and constipation for the two groups were 63.8% and 7.7% (χ 2 =71.52, P=0.000), respectively. The incidence of ≥2 grade esophagitis of CC group and R group were 48.57% and 38.46% (χ 2 =2.17, P=0.141), respectively. The incidence of ≥2

  6. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC: A direct comparison of PET-based treatment planning.

    Science.gov (United States)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Rübe, Christian

    2016-02-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels.

  7. Head and neck cancers: clinical benefits of three-dimensional conformal radiotherapy and of intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Giraud, P.; Jaulerry, C.; Brunin, F.; Zefkili, S.; Helfre, S.; Chauvet, I.; Rosenwald, J.C.; Cosset, J.M.

    2002-01-01

    The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) or intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3-D treatment planning systems, sophisticated immobilization systems and rigorous quality assurance and treatment verification. The central objective of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of normal tissues. These techniques would then allow further tumor dose escalation. Head-and-neck tumors are some of the most attractive localizations to test conformal radiotherapy. They combine ballistic difficulties due to particularly complex shapes (nasopharynx, ethmoid) and problems due to the number and low tolerance of neighbouring organs like parotids, eyes, brainstem and spinal cord. The therapeutic irradiation of head-and-neck tumors thus remains a challenge for the radiation oncologist. Conformal radiotherapy does have a significant potential for improving local control and reducing toxicity when compared to standard radiotherapy. However, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from 3DCRT and IMRT. The published clinical reports on the use of conformal radiotherapy are essentially dealing with dosimetric comparisons on relatively small numbers of patients. Recently, a few publications have emphasized the clinical experience several precursor teams with a suitable follow-up. This paper describes the current state-of-the-art of 3DCRT and IMRT in order to evaluate the impact of these techniques on head-and-neck cancers irradiation. (authors)

  8. A computer-controlled conformal radiotherapy system I: overview

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; McShan, Daniel L.; Kessler, Marc L.; Matrone, Gwynne M.; Lewis, James D.; Weaver, Tamar A.

    1995-01-01

    Purpose: Equipment developed for use with computer-controlled conformal radiotherapy (CCRT) treatment techniques, including multileaf collimators and/or computer-control systems for treatment machines, are now available. The purpose of this work is to develop a system that will allow the safe, efficient, and accurate delivery of CCRT treatments as routine clinical treatments, and permit modifications of the system so that the delivery process can be optimized. Methods and Materials: The needs and requirements for a system that can fully support modern computer-controlled treatment machines equipped with multileaf collimators and segmental or dynamic conformal therapy capabilities have been analyzed and evaluated. This analysis has been used to design and then implement a complete approach to the delivery of CCRT treatments. Results: The computer-controlled conformal radiotherapy system (CCRS) described here consists of a process for the delivery of CCRT treatments, and a complex software system that implements the treatment process. The CCRS system described here includes systems for plan transfer, treatment delivery planning, sequencing of the actual treatment delivery process, graphical simulation and verification tools, as well as an electronic chart that is an integral part of the system. The CCRS system has been implemented for use with a number of different treatment machines. The system has been used clinically for more than 2 years to perform CCRT treatments for more than 200 patients. Conclusions: A comprehensive system for the implementation and delivery of computer-controlled conformal radiation therapy (CCRT) plans has been designed and implemented for routine clinical use with multisegment, computer-controlled, multileaf-collimated conformal therapy. The CCRS system has been successfully implemented to perform these complex treatments, and is considered quite important to the clinical use of modern computer-controlled treatment techniques

  9. SU-E-T-346: Effect of Jaw Position On Dose to Critical Structures in 3-D Conformal Radiotherapy Treatment of Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Paudel, N; Han, E; Liang, X; Morrill, S; Zhang, X; Hardee, M; Penagaricano, J; Ratanatharathorn, V [Vaneerat, University of Arkansas for Medical Sciences, Little Rock, AR (United States)

    2015-06-15

    Purpose: Three-dimensional conformal therapy remains a valid and widely used modality for pancreatic radiotherapy treatment. It usually meets dose constraints on critical structures. However, careful positioning of collimation jaws can reduce dose to the critical structures. Here we investigate the dosimetric effect of jaw position in MLC-based 3-D conformal treatment planning on critical structures. Methods: We retrospectively selected seven pancreatic cancer patients treated with 3-D conformal radiotherapy. We started with treatment plans (Varian Truebeam LINAC, Eclipse TPS, AAA, 18MV) having both x and y jaws aligned with the farthest extent of the block outline (8mm around PTV). Then we subsequently moved either both x-jaws or all x and y jaws outwards upto 3 cm in 1 cm increments and investigated their effect on average and maximum dose to neighboring critical structures keeping the same coverage to treatment volume. Results: Lateral displacement of both x-jaws by 1cm each increased kidney and spleen mean dose by as much as 1.7% and 1.3% respectively and superior inferior displacement increased liver, right kidney, stomach and spleen dose by as much as 2.1%, 2%, 5.2% and 1.6% respectively. Displacement of all x and y-jaws away by 1cm increased the mean dose to liver, right kidney, left kidney, bowels, cord, stomach and spleen by as much as 4.9%, 5.9%, 2.1%, 2.8%, 7.4%, 10.4% and 4.2% respectively. Percentage increase in mean dose due to 2 and 3cm jaw displacement increased almost linearly with the displaced distance. Changes in maximum dose were much smaller (mostly negligible) than the changes in mean dose. Conclusion: Collimation jaw position affects dose mostly to critical structures adjacent to it. Though treatment plans with MLCs conforming the block margin usually meet dose constraints to critical structures, keeping jaws all the way in, to the edge of the block reduces dose to the critical structures during radiation treatment.

  10. A neurosurgery/stereotactic radiotherapy dedicated PACS for conformal radiotherapy

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Bocquiault, P.; Levrier, M.; Merienne, L.; Schlienger, M.

    1995-01-01

    To realise conformal cerebral stereotactic irradiations we use a Neurosurgery/stereotactic dedicated PACS between two distant hospitals. It connects the stereotactic neurosurgery planification imaging system NEUROAXIS (Sopelem-Sofretec/Ste Anne Hospital) with the dosimetric TPS ARTEMIS-3D/Dosigray (Tenon Hospital). NEUROAXIS is a computer aided stereotactic biopsies and stereo-electroencephalographies, used by surgeons in operating room. The system determines the precise location data for Talairach radiological equipment (X ray source at 5 meters from film) and the geometry of scanner and MRI stereotactical referentials. It provides a full set of features for lesion localization, geometrical computations, surgical planifications, picture archiving, stereotactic angiography, CT and MRI image processing and networking. It sends images through the French public digital network ISDN (NUMERIS/France Telecom : 2x64 Kbits/s) from Ste Anne to Tenon Hospital. Stereotactic angiographic and CT images are reformatted into the DOSIGRAY image processing environment where 3-D dose distributions, displays and DVHs are computed to determine the optimal treatment. ARTEMIS-3D/Dosigray is a TPS for stereotactic radiotherapy devised by the Tenon Hospital for clinical methodology and 3D dose calculations, optimization software development and the Dosigray company for multimodality imaging, (2D(3D)) computer graphics for dose and anatomical representation and data networking. Communication within the radiation oncology department is provided by local area ETHERNET network, linking heterogeneous systems (Vaxstations-3200; Decstation (5000(240))) by means of different protocols. The works in progress are to send back via the same network the 3-D dose matrix to Neurosurgery department NEUROAXIS system. Our PACS is used since six months to treat patients. It has permitted to improve the treatment quality in comparison with our first version TPS ARTEMIS-3D

  11. Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Wang, Xin; Li, Guangjun; Zhang, Yingjie; Bai, Sen; Xu, Feng; Wei, Yuquan; Gong, Youling

    2013-01-01

    To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMAT plans successfully achieved better target dose conformity, reduced the V 20/30 , and mean dose of the left kidney, as well as the V 20/30 of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V 20 of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6 Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future

  12. Major Late Toxicities After Conformal Radiotherapy for Nasopharyngeal Carcinoma-Patient- and Treatment-Related Risk Factors

    International Nuclear Information System (INIS)

    Lee, Anne W.M.; Ng, W.T.; Hung, W.M.; Choi, C.W.; Tung, Raymond; Ling, Y.H.; Cheng, Peter T.C.; Yau, T.K.; Chang, Amy T.Y.; Leung, Samuel K.C.; Lee, Michael C.H.; Bentzen, Soren M.

    2009-01-01

    Purpose: To retrospectively analyze the factors affecting late toxicity for nasopharyngeal carcinoma. Methods and Materials: Between 1998 and 2003, 422 patients were treated with a conformal technique with 2-Gy daily fractions to a total dose of 70 Gy. Conventional fractionation (5 fractions weekly) was used in 232 patients and accelerated fractionation (6 fractions weekly) in 190 patients. One hundred seventy-one patients were treated with the basic radiotherapy course alone (Group 1), 55 patients had an additional boost of 5 Gy in 2 fractions (Group 2), and 196 patients underwent concurrent cisplatin-based chemotherapy (Group 3). Results: The 5-year overall toxicity rate was significantly greater in Group 3 than in Group 1 (37% vs. 27%, p = 0.009). Although the overall rate in Group 2 was not elevated (28% vs. 27%, p = 0.697), a significant increase in temporal lobe necrosis was observed (4.8% vs. 0%, p = 0.015). Multivariate analyses showed that age and concurrent chemotherapy were significant factors. The hazard ratio of overall toxicity attributed to chemotherapy was 1.99 (95% confidence interval, 1.32-2.99, p = 0.001). The mean radiation dose to the cochlea was another significant factor affecting deafness, with a hazard ratio of 1.03 (95% confidence interval, 1.01-1.05, p = 0.005) per 1-Gy increase. The cochlea that received >50 Gy had a significantly greater deaf rate (Group 1, 18% vs. 7%; and Group 3, 22% vs. 14%). Conclusion: The therapeutic margin for nasopharyngeal carcinoma is extremely narrow, and a significant increase in brain necrosis could result from dose escalation. The significant factors affecting the risk of deafness included age, concurrent chemoradiotherapy, and greater radiation dose to the cochlea

  13. Computer controlled multi-leaf conformation radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, T [Tokyo Metropolitan Komagome Hospital (Japan); Inamura, K

    1981-10-01

    A conformation radiotherapy system with 5-split collimators of which openings can be controlled symmetrically by computerized techniques during rotational irradiation by a linear accelerator has been developed. Outline of the system performance and its clinical applications are described as follows. 1. Profile of the system: The hardware is composed of three parts, namely, the multi-split collimator, the electronic data processor, and the interface between those two parts. 1) The multi-leaf collimator is composed of 5 pairs (10 leaves) diaphragms. It can be mounted to the X-ray head of a linear accelerator when used, and can be dismounted after its use. 2) The electronic data processor sends control signal to the collimator according to the 5-leaf target volume data which can be stored into a minifloppy disc through the curve digitizer previously. This part is composed of a) dedicated micro processor, b) I/O expansion unit, c) color CRT display with key board, d) dual mini-floppy disc unit, e) curve digitizer and f) digital plotter for recording and verification of resulted accuracy. 2. Performance of the system: 1) Maximum field size: 15 cm x 15 cm at isocenter. 2) Maximum elongation ratio of the target volume: 3 : 1 when the longer diameter is 15 cm. 3) Control accuracy: Within +-3 mm deviation from planned beam focus at isocenter. 3. Clinical application: The method of treatment planning and clinical advantages of this irradiation method are explained by raising clinical experiences such as treating brain tumor and rectal cancer.

  14. Computer controlled multi-leaf conformation radiotherapy

    International Nuclear Information System (INIS)

    Matsuda, Tadayoshi; Inamura, Kiyonari.

    1981-01-01

    A conformation radiotherapy system with 5-split collimators of which openings can be controlled symmetrically by computerized techniques during rotational irradiation by a linear accelerator has been developed. Outline of the system performance and its clinical applications are described as follows. 1. Profile of the system: The hardware is composed of three parts, namely, the multi-split collimator, the electronic data processor, and the interface between those two parts. 1) The multi-leaf collimator is composed of 5 pairs (10 leaves) diaphragms. It can be mounted to the X-ray head of a linear accelerator when used, and can be dismounted after its use. 2) The electronic data processor sends control signal to the collimator according to the 5-leaf target volume data which can be stored into a minifloppy disc through the curve digitizer previously. This part is composed of a) dedicated micro processor, b) I/O expansion unit, c) color CRT display with key board, d) dual mini-floppy disc unit, e) curve digitizer and f) digital plotter for recording and verification of resulted accuracy. 2. Performance of the system: 1) Maximum field size: 15 cm x 15 cm at isocenter. 2) Maximum elongation ratio of the target volume: 3 : 1 when the longer diameter is 15 cm. 3) Control accuracy: Within +-3 mm deviation from planned beam focus at isocenter. 3. Clinical application: The method of treatment planning and clinical advantages of this irradiation method are explained by raising clinical experiences such as treating brain tumor and rectal cancer. (author)

  15. Three-dimensional conformal radiotherapy in the treatment of prostate cancer in Australia and New Zealand: Report on a survey of radiotherapy centres and the proceedings of a consensus workshop

    International Nuclear Information System (INIS)

    Tai, K.-H.; Duchesne, G.; See, A.; Berry, M.

    2004-01-01

    There is an increasing use of 3-D conformal radiotherapy (3DCRT) in the radiotherapeutic management of prostate cancer. The Faculty of Radiation Oncology Genito-Urinary Group carried out a survey of Australian and New Zealand radiotherapy centres in the preparation of a consensus workshop. Of the 19 centres that were represented, there were 24 radiation oncologists, 16 radiation therapists and 12 medical physicists. The survey collected demographic information and data on the practices undertaken at those centres when delivering curative radiotherapy in the treatment of prostate cancer. There was much variation in the delivery of treatment in the areas of patient set-up, contouring of target volumes and organs of interest during computer planning, the techniques and the dose constraints used in these techniques, the use of adjuvant androgen deprivation therapy and the quality assurance processes used in monitoring effects of treatment. This variability reflects the range of data in the published literature. Emerging trends of practices were also identified. This is a first report on a multi-disciplinary approach to the development of guidelines in 3DCRT of prostate cancer. Copyright (2004) Blackwell Science Pty Ltd

  16. Transition from 2-D radiotherapy to 3-D conformal and intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    2008-05-01

    Cancer is one of the leading causes of death globally and radiotherapy is currently an essential component in the management of cancer patients, either alone or in combination with surgery or chemotherapy, both for cure or palliation. It is now recognized that safe and effective radiotherapy service needs not only substantial capital investment in radiotherapy equipment and specially designed facilities but also continuous investment in maintenance and upgrading of the equipment to comply with the technical progress, but also in training the staff. The recent IAEA-TECDOC publication 'Setting up a Radiotherapy Programme: Clinical, Medical Physics, Radiation Protection and Safety Aspects' provides general guidelines for designing and implementing radiotherapy services in Member States. Advances in computer technology have enabled the possibility of transitioning from basic 2- dimensional treatment planning and delivery (2-D radiotherapy) to a more sophisticated approach with 3-dimensional conformal radiotherapy (3-D CRT). Whereas 2-D radiotherapy can be applied with simple equipment, infrastructure and training, transfer to 3-D conformal treatments requires more resources in technology, equipment, staff and training. A novel radiation treatment approach using Intensity Modulated Radiation Therapy (IMRT) that optimizes the delivery of radiation to irregularly shaped tumour volumes demands even more sophisticated equipment and seamless teamwork, and consequentially more resources, advanced training and more time for treatment planning and verification of dose delivery than 3-D CRT. Whereas 3-D CRT can be considered as a standard, IMRT is still evolving. Due to the increased interest of Member States to the modern application of radiotherapy the IAEA has received a number of requests for guidance coming from radiotherapy departments that wish to upgrade their facilities to 3-D CRT and IMRT through Technical Cooperation programme. These requests are expected to increase

  17. Three dimensional conformal radiotherapy for the treatment of prostate cancer: low risk of chronic rectal morbidity observed in a large series of patients

    International Nuclear Information System (INIS)

    Sandler, Howard M.; McLaughlin, P. William; Ten Haken, Randall K.; Addison, Heather; Forman, Jeffrey; Lichter, Allen

    1995-01-01

    Purpose: Three dimensional conformal radiotherapy (3D CRT) may provide a technique to increase the dose delivered to target tissues while sparing uninvolved normal structures. To evaluate the role of 3D treatment in reducing the treatment toxicity, we analyzed the chronic rectal morbidity observed in a large group of patients undergoing radiotherapy for prostate cancer. Methods and Materials: From 1987 through 1992, 721 prostate cancer patients were treated with 3D CRT at the University of Michigan or Providence Hospital. All had axial computed tomography (CT) specifically for RT planning, multiple structures contoured on the axial images, and beam's-eye-view conformal beams edited to provide 3D dose coverage. Using current American Joint Commission (AJCC) staging, 537 patients had T1-T2 tumors, 123 had T3-T4 tumors, and 60 were treated postprostatectomy. Pelvic lymph nodes were treated in 462 patients. Prostate boosts were delivered with four-field axial, six-field axial, or four-field oblique, nonaxial fields. The median dose was 68.40 Gy (range 59.4-80.4). Median follow-up was 20.4 months; 175 were followed more than 3 years. All complications have been graded conservatively using the RTOG system. Results: Using a Cox proportional hazard's model, patient age, T-stage, prescribed dose, pelvic treatment, and boost technique were analyzed. The factor most strongly related to risk of morbidity was dose (p = 0.05); however, the boost technique was also related: the four-field oblique field had the lowest relative risk. Most episodes of rectal morbidity have been mild: 82 Grade 1 or 2. There have been only 14 more serious complications including 12 Grade 3 and 2 Grade 4. The actuarial risk of a Grade 3 or 4 complication is 3% at 3 and 5 years. Conclusions: A very small proportion of patients treated with 3D CRT had significant rectal morbidity related to RT, supporting the use of conformal treatment planning and dose delivery as a mechanism to minimize complications

  18. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    International Nuclear Information System (INIS)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian

    2016-01-01

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [de

  19. Three-Dimensional Non-Coplanar Conformal Radiotherapy Yields Better Results Than Traditional Beam Arrangements for Adjuvant Treatment of Gastric Cancer

    International Nuclear Information System (INIS)

    Soyfer, Viacheslav; Corn, Benjamin W.; Melamud, Alex B.S.; Alani, Shlomi; Tempelhof, Haim; Agai, Reuben; Shmueli, Anat; Figer, Arie; Kovner, Felix

    2007-01-01

    Purpose: The current standard of adjuvant treatment for gastric cancer after curative resection is concurrent administration of radiotherapy and 5-fluorouracil-based chemotherapy. The radiation fields are often arranged as anterioposterior-posteroanterior opposed parallel fields with general recommendations for sparing at least two-thirds of one kidney. We investigated whether a better radiation distribution would be achievable with three-dimensional conformal approaches compared with the classic anterioposterior-posteroanterior fields. Methods and Materials: A total of 19 patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a non-coplanar four-field arrangement. In each case, parallel planning using an anterioposterior-posteroanterior arrangement and a four-field 'box' was performed, and the generated plans were subsequently compared for coverage of target volumes and doses to irradiated organs next to the tumor bed. A separate analysis was performed for kidneys exposed to greater and lower doses in each patient. The mean radiation dose and percentage of kidney volume receiving a dose >20 Gy were registered. Statistical analysis was performed using the two-tailed t test. Results: The clinical target volume was adequately covered in all three plans. In the greater-dose kidney group, all the differences were statistically significant with a benefit for the three-dimensional plan. In the lower-dose kidney group, the differences in the mean radiation dose did not reach the level of statistical significance, and the differences in the kidney volume receiving a dose >20 Gy showed a statistically significant benefit for the three-dimensional plan. Conclusion: Non-coplanar three-dimensional-based conformal planning for postoperative radiotherapy for gastric cancer provided the best results regarding kidney and spinal cord exposure with adequate clinical target volume coverage. This technique was readily implemented in clinical

  20. Three-dimensional non-coplanar conformal radiotherapy yields better results than traditional beam arrangements for adjuvant treatment of gastric cancer.

    Science.gov (United States)

    Soyfer, Viacheslav; Corn, Benjamin W; Melamud, Alex; Alani, Shlomi; Tempelhof, Haim; Agai, Reuben; Shmueli, Anat; Figer, Arie; Kovner, Felix

    2007-10-01

    The current standard of adjuvant treatment for gastric cancer after curative resection is concurrent administration of radiotherapy and 5-fluorouracil-based chemotherapy. The radiation fields are often arranged as anterioposterior-posteroanterior opposed parallel fields with general recommendations for sparing at least two-thirds of one kidney. We investigated whether a better radiation distribution would be achievable with three-dimensional conformal approaches compared with the classic anterioposterior-posteroanterior fields. A total of 19 patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a non-coplanar four-field arrangement. In each case, parallel planning using an anterioposterior-posteroanterior arrangement and a four-field "box" was performed, and the generated plans were subsequently compared for coverage of target volumes and doses to irradiated organs next to the tumor bed. A separate analysis was performed for kidneys exposed to greater and lower doses in each patient. The mean radiation dose and percentage of kidney volume receiving a dose >20 Gy were registered. Statistical analysis was performed using the two-tailed t test. The clinical target volume was adequately covered in all three plans. In the greater-dose kidney group, all the differences were statistically significant with a benefit for the three-dimensional plan. In the lower-dose kidney group, the differences in the mean radiation dose did not reach the level of statistical significance, and the differences in the kidney volume receiving a dose >20 Gy showed a statistically significant benefit for the three-dimensional plan. Non-coplanar three-dimensional-based conformal planning for postoperative radiotherapy for gastric cancer provided the best results regarding kidney and spinal cord exposure with adequate clinical target volume coverage. This technique was readily implemented in clinical practice.

  1. Dosimetry comparison of irradiation with conformal radiotherapy, intensity modulated radiotherapy, conformal radiotherapy in stereotactic conditions and robotic stereotactic radiotherapy for benign brain tumours

    International Nuclear Information System (INIS)

    Spasic, E.; Noel, A.; Buchheit, I.; Bernier, V.

    2011-01-01

    Purpose. - To compare several techniques in order to determine the best treatment for benign brain tumours. Methods and patients. - A retrospective study was performed for five patients who received 3D-conformal radiotherapy, intensity modulated radiotherapy or CyberKnife R . These patients had a meningioma, a pituitary tumour, a cranio-pharyngioma or a neurinoma. In each case, these treatment plans were optimised and compared with the three other dosimetries. Radiobiological or positioning parameters were evaluated, as well as dosimetric parameters, in order to compare treatments with different characteristics. Results. - The dosimetric parameters showed that the choice of treatment seemed to be determined mostly by tumour size, shape and proximity with organs at risk (not tumour localisation). Whereas the results showed no significant deviations with regards to the radiobiological parameters. Therefore, with these parameters, it was difficult to give priority to a treatment. Conclusions. - With regards to benign brain tumours of medium or large size, intensity modulated radiotherapy seemed the recommended treatment. It enabled to obtain a good ratio between efficacy and toxicity for tumours that are really close to organs at risk. Concerning small benign brain tumours, the CyberKnife R was probably the best treatment. (authors)

  2. The value of 18F-FDG PET in three-dimensional conformal radiotherapy of cancer

    International Nuclear Information System (INIS)

    Lv Huiqing; Zhang Zhongmin; Lv Zhonghong

    2006-01-01

    Three-dimensional conformal radiotherapy (3D-CRT) is based on an extensive use of modern medical imaging techniques. Delineation of the gross tumor volume and organs at risk constitutes one of the most important phases of conformal radiotherapy procedures. 18 F-fluorodeoxyglucose ( 18 F-FDG) PET possesses greater sensitivity and accuracy in detecting diseased lymph nodes, is an important staging examination for patients considered for radiation treatment with curative intent. 18 F-FDG PET has an important role in delineation of gross tumor volume for patients treated with three-dimensional conformal radiotherapy. (authors)

  3. Evaluation of the treatment planning system of three-dimensional conformal external radiotherapy in Hospital Mexico of San Jose, Costa Rica

    International Nuclear Information System (INIS)

    Venegas Rojas, Deybith

    2014-01-01

    An evaluation and analysis are realized of dosimetry of the treatment planning system (TPS) of three-dimensional conformal external radiotherapy in the Servicio de Radioterapia of the Hospital Mexico of Costa Rica. An evaluation procedure is proposed based on IAEA-TECDOC-1540 document, and may continue to be applied periodically in this or other radiotherapy services. Tests realized have checked the representation of distances and electronics densities transferred to the TPS, match with those of real objects. The 16 tests applied have represented situations of real treatments with different configurations and beam modifiers in the equipment used daily. The tests have measured the absorbed dose to water in different significant points at different depths, using photon beams of 6 MeV and 18 MeV. The physical parameters of the tests were simulated. The absorbed dose has been calculated at specified points. The XiO and Eclipse TPS have been used with the calculation algorithms: Superposition, Convolution and AAA. The results of the calculations are evaluated with statistical methods and comparing them with the measurements of absorbed dose. A generalized tendency has been detected toward negative relative errors, implying an underestimation of the dose by the TPS; due to a difference found in the accelerator output factor respect to its commissioning. The AAA algorithm has determined a better performance, although with greater difficulties of calculus in the region of build-up. Convolution and Superposition algorithms have had similar performances and both have presented problems in high depths and out of edges of the fields. The result of the dosimetric evaluation has been satisfactory in real conditions of equipment; but several particularities have been found that should be reviewed and adjusted. The precision of the TPS has been adequate in the majority of situations important for treatment planning. [author] [es

  4. Extracranial stereotactic radiotherapy: Evaluation of PTV coverage and dose conformity

    International Nuclear Information System (INIS)

    Haedinger, U.; Thiele, W.; Wulf, J.

    2002-01-01

    During the past few years the concept of cranial sterotactic radiotherapy has been successfully extended to extracranial tumoral targets. In our department, hypofractionated treatment of tumours in lung, liver, abdomen, and pelvis is performed in the Stereotactic Body Frame (ELEKTA Instrument AB) since 1997. We present the evaluation of 63 consecutively treated targets (22 lung, 21 liver, 20 abdomen/pelvis) in 58 patients with respect to dose coverage of the planning target volume (PTV) as well as conformity of the dose distribution. The mean PTV coverage was found to be 96.3%±2.3% (lung), 95.0%±4.5% (liver), and 92.1%±5.2% (abdomen/pelvis). For the so-called conformation number we obtained values of 0.73±0.09 (lung), 0.77±0.10 (liver), and 0.70±0.08 (abdomen/pelvis). The results show that highly conformal treatment techniques can be applied also in extracranial stereotactic radiotherapy. This is primarily due to the relatively simple geometrical shape of most of the targets. Especially lung and liver targets turned out to be approximately spherically/cylindrically shaped, so that the dose distribution can be easily tailored by rotational fields. (orig.) [de

  5. Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

    International Nuclear Information System (INIS)

    Scalchi, Paolo; Righetto, Roberto; Cavedon, Carlo; Francescon, Paolo; Colombo, Federico

    2010-01-01

    Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of

  6. Conformal radiotherapy for locally advanced juvenile nasopharyngeal angio-fibroma

    Directory of Open Access Journals (Sweden)

    Supriya Mallick

    2015-01-01

    Full Text Available Purpose: To assess the efficacy of radiation in the treatment of juvenile nasopharyngeal angiofibroma (JNA. Materials and Methods: Data were retrieved for JNA treated with radiotherapy from 1987-2012. The demographics, treatment and outcome data were recorded in predesigned proforma. Results: Data of 32 patients were retrieved. Median age was 17 years (range: 12-33 years. All patients received radiation because of refractory, residual or unresectable locally advanced disease. All patients were planned with a three-dimensional conformal technique (3DCRT. The median radiation dose was 30 Gray (range: 30-45 Gray. Median follow-up was 129 months (range: 1-276 months. At the last follow-up, 13 patients were found to have a radiological complete response. Two patients progressed 38 and 43 months after completion of treatment and opted for alternative treatment. One patient developed squamous cell carcinoma of the nasal ale 15 years after radiation. Conclusion: Conformal radiotherapy shows promise as an alternative treatment approach for locally advanced JNA and confers long-term disease control with minimal toxicity.

  7. Metallic stent and stereotactic conformal radiotherapy for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Yu; Wang Ning; Tian Qihe; Guo Zhanwen; Zhang Haibo; Song Liyan

    2005-01-01

    Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 ± 4.6 months, compared with 5.1 ± 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)

  8. Three-dimensional treatment planning for postoperative radiotherapy in patients with node-positive cervical cancer. Comparison between a conventional and a conformal technique

    Energy Technology Data Exchange (ETDEWEB)

    Olofsen-van Acht, M.J.J.; Quint, S.; Seven, M.; Berg, H.A. van den; Levendag, P.C. [University Hospital Rotterdam (Netherlands). Dept. of Radiation Oncology; Santvoort, J.P.C. van [University Hospital Rotterdam (Netherlands). Subdivision of Clinical Physics; Logmans, A. [University Hospital Rotterdam (Netherlands). Dept. of Gynecologic Oncology

    1999-09-01

    Purpose: Reduction of irradiated small bowel volume, using a conformal three-dimensional treatment planning technique in postoperative radiotherapy of cervical cancer patients. Patients and Methods: Large gynecological treatment fields including the para-aortic nodes were analyzed in 15 patients. A conventional treatment plan with anterior and posterior (AP-PA) parallel opposed fields and a 3D 4-field conformal radiotherapy plan with a central blocking of small bowel were compared for each patient. Dose-volume histograms and dose parameters were established. Because of the tolerance constraints of the small bowel, the cumulative dose applied to the target was 48.6 Gy. Results: The mean Tumor Control Probability (TCP) values for both the conventional and the conformal technique were 0.60 and 0.61, respectively, with ranges of 0.56 to 0.67 and 0.57 to 0.66, respectively. The mean volume receiving 95% or more of the prescribed dose (V95) of the small bowel was 47.6% (32.5 to 66.3%) in the AP-PA technique and 14.9% (7.0 to 22.5%) in the conformal technique (p<0.001), indicating a significant reduction in irradiated volume of small bowel in the higher dose range. The mean Normal Tissue Complication Probability (NTCP) decreased from 0.11 to 0.03 with the conformal plan. In patients who received a pedicled omentoplasty during surgery, the mean V95 for small bowel could be reduced to 8.5% (7.0 to 9.9%). The mean median dose to the kidneys was only slightly elevated in the conformal treatment. Especially the mean dose to the right kidney in conventional vs conformal treatment was 3.3 vs 7.9 Gy. The mean near-minimum dose (D95) to the rectosigmoid decreased from 48.4 to 30.1 Gy in the conformal plan compared to the conventional plan. Conclusion: The small bowel dose can be significantly reduced with 3D treatment planning, particularly if a predicled omentoplasty is performed. This allows dose escalation to the tumor region without unacceptable toxicity for the small bowel

  9. The place of conformal radiotherapy in the routine work: national investigation of SFRO members'opinion

    International Nuclear Information System (INIS)

    Lagrange, J.L.; Lipinski, F.

    2001-01-01

    National French investigation of the using of conformal radiotherapy in routine work, has been made in 2001, in 180 radiotherapeutic centers. Eighty responses have been obtained and analyzed. Conformal radiotherapy is used in 88% and virtual simulation in 60% of these centers. There is a heterogeneity in the equipment of these institutions, most of them have one or two machines. The accelerator equipment differs, and the availability of multi-leaf collimators and electronic portal imaging is limited. Actually only eleven centers have IMRT, eight have projects to install. Only six centers have CT-scans, used mainly for simulation. In 75% of centers conformal radiotherapy have been used in the treatment of CNS-tumors, head and neck cancers, prostate, and non-small cell lung carcinoma. If there are more equipment and human facilities to use conformal radiotherapy, this treatment can be proposed to patients with breast cancer, rectal and gynecological tumors. According 90% of responses, all prostatic cancers need conformal radiotherapy. The analysis of routine use of conformal radiotherapy in France shows an important heterogeneity but it seems that there is an agreement with objectives of this treatment. (authors)

  10. Analysis of the efficacy and safety of conventional radiotherapy of chest wall and clavicular field and three-dimensional conformal radiotherapy in patients after modified radical mastectomy

    Directory of Open Access Journals (Sweden)

    Song-Lin Wang

    2017-04-01

    Full Text Available Objective: To explore the efficacy and safety of conventional radiotherapy of chest wall and clavicular field and three-dimensional conformal radiotherapy in patients after modified radical mastectomy. Methods: A total of 84 patients who were admitted in our hospital after modified radical mastectomy were included in the study and divided into the conventional radiotherapy group (n=42 and the three-dimensional conformal radiotherapy group (n=42 according to different radiotherapy methods. The patients in the conventional radiotherapy group were given conventional radiotherapy of chest wall and clavicular field, while the patients in the three-dimensional conformal radiotherapy group were given three-dimensional conformal radiotherapy. The serum tumor markers and peripheral blood T lymphocyte subsets 6-8 weeks after treatment in the two groups were detected. The clinical efficacy, and toxic and side effects in the two groups were evaluated. Results: The serum CA15-3, CA125, CEA, and CK19 levels after treatment in the two groups were significantly reduced when compared with before treatment, CD3 +,CD4 +, and CD4 +/CD8 + were significantly elevated, while CD8 + was significantly reduced when compared with before treatment, but the comparison of the above indicators between the two groups was not statistically significant. The occurrence rate of radioactive skin damage and pneumonia after treatment in the conventional radiotherapy group was significantly higher than that in the three-dimensional conformal radiotherapy group. Conclusions: The two kinds of radiotherapy schemes have an equal efficacy, but the toxic and side effects of three-dimensional conformal radiotherapy are significantly lower than those by the conventional radiotherapy, with a certain advantage.

  11. Radiotherapy of intensity modulated VS conformational in the treatment of carcinoma of the prostate. A dosimetric comparison; Radioterapia de intensidad modulada VS conformacional en el tratamiento de carcinoma de prostata. Una camparacion dosimetrica

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Martin, G.; Garcia Vicente, F.; Zapatero Laborda, A.; Bermudez Luna, R.; Roch Gonzalez, M.; Perez Gonzalez, L.; Torres Escobar, J. J.

    2013-07-01

    The intensity modulated (IMRT) radiation therapy is a technique of high conformation which, by its nature, has as one of its main directions prostate cancer radiotherapy treatment. The purpose of this work is presents results of the dosimetric indicators collected in our hospital a number of patients of carcinoma of the prostate with standard three-dimensional Conformal technique (3D-CRT) and IMRT. Aims to demonstrate and quantify with a statistical methodology that, establishing an adequate Protocol of IMRT, significant reductions in risk organ doses can be obtained by keeping the same prescription to the white volume. (Author)

  12. Conformal radiotherapy of urinary bladder cancer

    International Nuclear Information System (INIS)

    Muren, Ludvig Paul; Smaaland, Rune; Dahl, Olav

    2004-01-01

    Recent advances in radiotherapy (RT) are founded on the enhanced tumour visualisation capabilities of new imaging modalities and the precise deposition of individualised radiation dose distributions made possible with the new systems for RT planning and delivery. These techniques have a large potential to also improve the results of RT of urinary bladder cancer. Major challenges to take full advantage of these advances in the management of bladder cancer are to control, and, as far as possible, reduce bladder motion, and to reliably account for the related intestine and rectum motion. If these obstacles are overcome, it should be possible in the near future to offer selected patients with muscle invading bladder cancer an organ-sparing, yet effective combined-modality treatment as an alternative to radical surgery

  13. On-line estimations of delivered radiation doses in three-dimensional conformal radiotherapy treatments of carcinoma uterine cervix patients in linear accelerator.

    Science.gov (United States)

    Putha, Suman Kumar; Saxena, P U; Banerjee, S; Srinivas, Challapalli; Vadhiraja, B M; Ravichandran, Ramamoorthy; Joan, Mary; Pai, K Dinesh

    2016-01-01

    Transmission of radiation fluence through patient's body has a correlation to the planned target dose. A method to estimate the delivered dose to target volumes was standardized using a beam level 0.6 cc ionization chamber (IC) positioned at electronic portal imaging device (EPID) plane from the measured transit signal (S t ) in patients with cancer of uterine cervix treated with three-dimensional conformal radiotherapy (3DCRT). The IC with buildup cap was mounted on linear accelerator EPID frame with fixed source to chamber distance of 146.3 cm, using a locally fabricated mount. S t s were obtained for different water phantom thicknesses and radiation field sizes which were then used to generate a calibration table against calculated midplane doses at isocenter (D iso,TPS ), derived from the treatment planning system. A code was developed using MATLAB software which was used to estimate the in vivo dose at isocenter (D iso,Transit ) from the measured S t s. A locally fabricated pelvic phantom validated the estimations of D iso,Transit before implementing this method on actual patients. On-line dose estimations were made (3 times during treatment for each patient) in 24 patients. The D iso,Transit agreement with D iso,TPS in phantom was within 1.7% and the mean percentage deviation with standard deviation is -1.37% ±2.03% ( n = 72) observed in patients. Estimated in vivo dose at isocenter with this method provides a good agreement with planned ones which can be implemented as part of quality assurance in pelvic sites treated with simple techniques, for example, 3DCRT where there is a need for documentation of planned dose delivery.

  14. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Munzenrider, J.E.; Liebsch, N.J.; O'Farrell, D.; Efird, J.; Daly, W.; Suit, H.D.

    1996-01-01

    Purpose/Objective: Brainstem tolerance to inhomogenous radiation doses applied by modern conformal radiotherapy has not yet been examined. The aim of this study was to analyse the incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Materials and Methods: Between 1974 and 1995, 367 patients with chordomas (n=195) and chondrosarcomas (n=172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. All patients had previously undergone biopsy, subtotal or total tumor removal. 104 patients had two or more surgical procedures before radiotherapy. Following 3D treatment planning with delineation of target volumes and critical non-target structures, dose distributions and dose volume histograms were calculated [at the time of treatment delivery]. Radiotherapy was given once a day, 1.8 Gy or CGE (Cobalt Gy Equivalent: Proton Gy X 1.1) per fraction, 5 fractions per week, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Dose distributions were developed to limit dose to brainstem surface and center; current plans limit dose to surface and center to ≤64 CGE and ≤53 CGE, respectively. Brainstem toxicity was scored according to the RTOG grading system. Results: Follow-up ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem symptoms, attributable to the treatment, developed in 17 of 282 patients with local tumor control (6.0%), resulting in death of three patients. The mean time to onset of symptoms was 17 months (range: 4.5 to 177 months). These symptoms appeared in 89.5% within 3 years. Grading of the brainstem toxicity is listed in table 1. Actuarial rates of 5 and 10 year toxicity free survival were 87% and 82% respectively. Increased risk of brainstem toxicity was significantly associated with maximum brainstem dose

  15. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Liebsch, N.J.; O'Farrel, D.; Finkelstein, D.; Efird, J.; Munzenrider, J.E.

    1997-01-01

    Purpose: The aim of this study was to analyze the long-term incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Methods and Materials: Between 1974 and 1995, 367 patients with chordomas (n = 195) and chondrosarcomas (n = 172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. Following 3D treatment planning with delineation of target volumes and critical nontarget structures dose distributions and dose-volume histograms were calculated. Radiotherapy was given an 1.8 Gy or CGE (=Cobalt Gray Equivalent) dose per fraction, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Results: Follow-up time ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem toxicity was observed in 17 of 367 patients attributable to treatment, resulting in death of three patients. Actuarial rates of 5 and 10-year high-grade toxicity-free survival were 94 and 88%, respectively. Increased risk of brainstem toxicity was significantly associated with maximum dose to brainstem, volume of brainstem receiving ≥50 CGE, ≥55 CGE, and ≥60 CGE, number of surgical procedures, and prevalence of diabetes or high blood pressure. Multivariate analysis identified three independent factors as important prognosticators: number of surgical procedures (p < 0.001), volume of the brainstem receiving 60 CGE (p < 0.001), and prevalence of diabetes (p < 0.01). Conclusions: Tolerance of brainstem to fractionated radiotherapy appears to be a steep function of tissue volume included in high dose regions rather than the maximum dose of brainstem alone. In addition, presence of predisposing factors as well as extent of surgical manipulation can significantly lower brainstem tolerance in the individual patient

  16. Beam shaping for conformal fractionated stereotactic radiotherapy: a modeling study

    International Nuclear Information System (INIS)

    Hacker, Fred L.; Kooy, Hanne M.; Bellerive, Marc R.; Killoran, Joseph H.; Leber, Zachary H.; Shrieve, Dennis C.; Tarbell, Nancy J.; Loeffler, Jay S.

    1997-01-01

    Purpose: The patient population treated with fractionated stereotactic radiotherapy (SRT) is significantly different than that treated with stereotactic radiosurgery (SRS). Generally, lesions treated with SRT are larger, less spherical, and located within critical regions of the central nervous system; hence, they offer new challenges to the treatment planner. Here a simple, cost effective, beam shaping system has been evaluated relative to both circular collimators and an ideal dynamically conforming system for effectiveness in providing conformal therapy for these lesions. Methods and Materials: We have modeled a simple system for conformal arc therapy using four independent jaws. The jaw positions and collimator angle are changed between arcs but held fixed for the duration of each arc. Eleven previously treated SRT cases have been replanned using this system. The rectangular jaw plans were then compared to the original treatment plans which used circular collimators. The plans were evaluated with respect to tissue sparing at 100%, 80%, 50%, and 20% of the prescription dose. A plan was also done for each tumor in which the beam aperture was continuously conformed to the beams eye view projection of the tumor. This was used as an ideal standard for conformal therapy in the absence of fluence modulation. Results: For tumors with a maximum extent of over 3.5 cm the rectangular jaw plans reduced the mean volume of healthy tissue involved at the prescription dose by 57% relative to the circular collimator plans. The ideal conformal plans offered no significant further improvement at the prescription dose. The relative advantage of the rectangular jaw plans decreased at lower isodoses so that at 20% of the prescription dose tissue involvement for the rectangular jaw plans was equivalent to that for the circular collimator plans. At these isodoses the ideal conformal plans gave substantially better tissue sparing. Conclusion: A simple and economical field shaping

  17. Conformal radiotherapy for 6 cases of bile duct carcinoma

    International Nuclear Information System (INIS)

    Kawasaki, Yoshiyuki; Suzuki, Takashi; Sugahara, Shinji

    1998-01-01

    Authors performed the conformal radiotherapy using the multileaf collimator for inoperable patients with bile duct carcinoma and examined the usefulness of this treatment. Forty one patients were examined, whose age was from 45 to 80 years (mean: 69.5 years), and whose ratio of men to women was 1 to 1.6. Patients in Group I (palliative irradiation, 30 cases) received bilateral irradiation using the linac with 4 MV-x-ray of total 50.0 Gy (2.0 Gy a dose, 5 times a week), those in Group II (palliative irradiation, 5 cases) using the microtron with 10 MV-x-ray of total 50.0 Gy (2.0 Gy a dose, 5 times a week). And those in Group III (radial irradiation, 6 cases) were first irradiated using the microtron with total 40.0 Gy (2.0 Gy a dose, 5 times a week) and secondly by the conformal radiotherapy with total 20.0 Gy (2.0 Gy a dose, 5 times a week). Patients in Group III were irradiated with total 60.0 Gy. Patients in all Groups showed mild side-effects including nausea and vomiting. And patients in Group III, who were irradiated 10 Gy more than other Group, showed no severe side-effects as alimentary bleeding, liver function disorders and cholangitis. In Group I, one year survivors were 3 (10.0%) and two years survivors were none. The median survival month was 7.2 months. In Group II, one year survivor was 1 (20.0%) and two years survivors were none. The median survival month was 8.1 months. In Group III, one year survivors were 2 (33.3%), and two years survivors were 2 (33.3%). The median survival month was 11.2 months. Two patients are survival at present (March, 1998), 2 years and 10 months, and 2 years and 9 months, respectively. The conformal radiotherapy gave better results than the ordinary radiotherapy. (K.H.)

  18. Three dimensional conformal postoperative radiotherapy for ...

    African Journals Online (AJOL)

    Introduction: Postoperative radiotherapy of the parotid gland could be achieved with various radiotherapy techniques. However they irradiate differently the surrounding organs at risk (OARs) in particular the cochlea, oral cavity & contralateral parotid causing significant increase in the risk of oral mucositis, xerostomia, and ...

  19. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC. A direct comparison of PET-based treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Jochen; Kremp, Katharina; Kremp, Stephanie; Palm, Jan; Ruebe, Christian [Saarland University Medical School, Department of Radiotherapy and Radiation Oncology, Homburg/Saar (Germany)

    2016-02-15

    The potential of intensity-modulated radiation therapy (IMRT) as opposed to three-dimensional conformal radiotherapy (3D-CRT) is analyzed for two different concepts of fluorodeoxyglucose positron emission tomography (FDG PET)-based target volume delineation in locally advanced non-small cell lung cancer (LA-NSCLC): involved-field radiotherapy (IF-RT) vs. elective nodal irradiation (ENI). Treatment planning was performed for 41 patients with LA-NSCLC, using four different planning approaches (3D-CRT-IF, 3D-CRT-ENI, IMRT-IF, IMRT-ENI). ENI included a boost irradiation after 50 Gy. For each plan, maximum dose escalation was calculated based on prespecified normal tissue constraints. The maximum prescription dose (PD), tumor control probability (TCP), conformal indices (CI), and normal tissue complication probabilities (NTCP) were analyzed. IMRT resulted in statistically significant higher prescription doses for both target volume concepts as compared with 3D-CRT (ENI: 68.4 vs. 60.9 Gy, p < 0.001; IF: 74.3 vs. 70.1 Gy, p < 0.03). With IMRT-IF, a PD of at least 66 Gy was achieved for 95 % of all plans. For IF as compared with ENI, there was a considerable theoretical increase in TCP (IMRT: 27.3 vs. 17.7 %, p < 0.00001; 3D-CRT: 20.2 vs. 9.9 %, p < 0.00001). The esophageal NTCP showed a particularly good sparing with IMRT vs. 3D-CRT (ENI: 12.3 vs. 30.9 % p < 0.0001; IF: 15.9 vs. 24.1 %; p < 0.001). The IMRT technique and IF target volume delineation allow a significant dose escalation and an increase in TCP. IMRT results in an improved sparing of OARs as compared with 3D-CRT at equivalent dose levels. (orig.) [German] Das Potenzial der intensitaetsmodulierten Strahlentherapie (IMRT) soll im Rahmen der FDG-PET basierten Bestrahlungsplanung des lokal fortgeschrittenen nichtkleinzelligen Bronchialkarzinoms (LA-NSCLC) fuer 2 Zielvolumenansaetze (Involved-Field-Bestrahlung, IF) sowie elektive Nodalbestrahlung (ENI) geprueft und mit der 3-D-konformalen Strahlentherapie (3-D

  20. 3D Conformal radiotherapy for gastric cancer-results of a comparative planning study

    International Nuclear Information System (INIS)

    Leong, Trevor; Willis, David; Joon, Daryl Lim; Condron, Sara; Hui, Andrew; Ngan, Samuel Y.K.

    2005-01-01

    Background and purpose: Many radiation oncologists are reluctant to use anteroposterior-posteroanterior (AP-PA) field arrangements when treating gastric cancer with adjuvant postoperative radiotherapy due to concerns about normal tissue toxicity, particularly in relation to the kidneys and spinal cord. In this report, we describe a multiple-field conformal radiotherapy technique, and compare this technique to the more commonly used AP-PA technique that was used in the recently reported Intergroup study (INT0116). Materials and methods: Fifteen patients with stages II-IV adenocarcinoma of the stomach were treated with adjuvant postoperative chemoradiotherapy using a standardised 3D conformal radiotherapy technique that consisted of a 'split-field', mono-isocentric arrangement employing 6 radiation fields. For each patient, a second radiotherapy treatment plan was generated utilising AP-PA fields. The two techniques were then compared for target volume coverage and dose to normal tissues using dose volume histogram (DVH) analysis. Results: The conformal technique provides more adequate coverage of the target volume with 99% of the planning target volume (PTV) receiving 95% of the prescribed dose, compared to 93% using AP-PA fields. Comparative DVHs for the right kidney, left kidney and spinal cord demonstrate lower radiation doses using the conformal technique, and although the liver dose is higher, it is still well below liver tolerance. Conclusions: 3D conformal radiotherapy produces superior dose distributions and reduced radiation doses to the kidneys and spinal cord compared to AP-PA techniques, with the potential to reduce treatment toxicity

  1. Comparison of anisotropic aperture based intensity modulated radiotherapy with 3D-conformal radiotherapy for the treatment of large lung tumors.

    Science.gov (United States)

    Simeonova, Anna; Abo-Madyan, Yasser; El-Haddad, Mostafa; Welzel, Grit; Polednik, Martin; Boggula, Ramesh; Wenz, Frederik; Lohr, Frank

    2012-02-01

    IMRT allows dose escalation for large lung tumors, but respiratory motion may compromise delivery. A treatment plan that modulates fluence predominantly in the transversal direction and leaves the fluence identical in the direction of the breathing motion may reduce this problem. Planning-CT-datasets of 20 patients with Stage I-IV non small cell lung cancer (NSCLC) formed the basis of this study. A total of two IMRT plans and one 3D plan were created for each patient. Prescription dose was 60 Gy to the CTV and 70 Gy to the GTV. For the 3D plans an energy of 18 MV photons was used. IMRT plans were calculated for 6 MV photons with 13 coplanar and with 17 noncoplanar beams. Robustness of the used method of anisotropic modulation toward breathing motion was tested in a 13-field IMRT plan. As a consequence of identical prescription doses, mean target doses were similar for 3D and IMRT. Differences between 3D and 13- and 17-field IMRT were significant for CTV Dmin (43 Gy vs. 49.1 Gy vs. 48.6 Gy; p3D: 12.5 Gy vs. 14.8 Gy vs. 15.8 Gy: p3D-plans. Heart D(max) was only marginally reduced with IMRT (3D vs. 13- vs. 17-field IMRT: 38.2 Gy vs. 36.8 Gy vs. 37.8 Gy). Simulated breathing motion caused only minor changes in the IMRT dose distribution (~0.5-1 Gy). Anisotropic modulation of IMRT improves dose delivery over 3D-RT and renders IMRT plans robust toward breathing induced organ motion, effectively preventing interplay effects. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Factors influencing conformity index in radiotherapy for non-small cell lung cancer.

    LENUS (Irish Health Repository)

    Brennan, Sinead M

    2010-01-01

    The radiotherapy conformity index (CI) is a useful tool to quantitatively assess the quality of radiotherapy treatment plans, and represents the relationship between isodose distributions and target volume. A conformity index of unity implies high planning target volume (PTV) coverage and minimal unnecessary irradiation of surrounding tissues. We performed this analysis to describe the CI for lung cancer 3-dimensional conformal radiotherapy (3DCRT) and to identify clinical and technical determinants of CI, as it is not known which factors are associated with good quality 3D conformal radiotherapy treatment planning. Radiotherapy treatment plans from a database of 52 patients with inoperable Stage 1 to 3b lung cancer, on a hypofractionated 3DCRT trial were evaluated. A CI was calculated for all plans using the definition of the ICRU 62:CI = (TV\\/PTV), which is the quotient of the treated volume (TV) and the PTV. Data on patient, tumor, and planning variables, which could influence CI, were recorded and analyzed. Mean CI was 2.01 (range = 1.06-3.8). On univariate analysis, PTV (p = 0.023), number of beams (p = 0.036), medial vs. lateral tumor location (p = 0.016), and increasing tumor stage (p = 0.041) were associated with improved conformity. On multiple regression analysis, factors found to be associated with CI included central vs. peripheral tumor location (p = 0.041) and PTV size (p = 0.058). The term 3DCRT is used routinely in the literature, without any indication of the degree of conformality. We recommend routine reporting of conformity indices. Conformity indices may be affected by both planning variables and tumor factors.

  3. Volumetric intensity-modulated arc therapy vs. 3-dimensional conformal radiotherapy for primary chemoradiotherapy of anal carcinoma. Effects on treatment-related side effects and survival

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Hanne Elisabeth; Droege, Leif Hendrik; Hennies, Steffen; Herrmann, Markus Karl; Wolff, Hendrik Andreas [University Medical Center Goettingen, Dept. of Radiotherapy and Radiooncology, Goettingen (Germany); Gaedcke, Jochen [University Medical Center Goettingen, Dept. of General Surgery, Goettingen (Germany)

    2015-11-15

    Primary chemoradiotherapy (CRT) is the standard treatment for locally advanced anal carcinoma. This study compared volumetric intensity-modulated arc therapy (VMAT) to 3-dimensional conformal radiotherapy (3DCRT) in terms of treatment-related side effects and survival. From 1992-2014, 103 consecutive patients with anal carcinoma UICC stage I-III were treated. Concomitant CRT consisted of whole pelvic irradiation, including the iliac and inguinal lymph nodes, with 50.4 Gy (1.8 Gy per fractions) by VMAT (n = 17) or 3DCRT (n = 86) as well as two cycles of 5-fluorouracil and mitomycin C. Acute organ and hematological toxicity were assessed according to the Common Terminology Criteria (CTC) for Adverse Events version 3.0. Side effects ≥ grade 3 were scored as high-grade toxicity. High-grade acute organ toxicity CTC ≥ 3 (P < 0.05), especially proctitis (P = 0.03), was significantly reduced in VMAT patients. The 2-year locoregional control (LRC) and disease-free survival (DFS) were both 100 % for VMAT patients compared with 80 and 73 % for 3DCRT patients. VMAT was shown to be a feasible technique, achieving significantly lower rates of acute organ toxicity and promising results for LRC and DFS. Future investigations will aim at assessing the advantages of VMAT with respect to late toxicity and survival after a prolonged follow-up time. (orig.) [German] Die primaere Radiochemotherapie (RCT) gilt als Standardtherapie fuer lokal fortgeschrittene Analkarzinome. In dieser Studie wurde die volumetrisch modulierte Rotationstherapie (''volumetric intensity-modulated arc therapy'', VMAT) mit der klassischen dreidimensionalen konformalen Radiotherapie (3DCRT) hinsichtlich therapieassoziierter Nebenwirkungen und Ueberleben verglichen. Von 1992-2014 wurden 103 aufeinanderfolgende Patienten mit einem Analkarzinom im UICC-Stadium I-III behandelt. Die kombinierte RCT bestand aus der Bestrahlung des gesamten Beckens inklusive der iliakalen und der inguinalen

  4. Parotid gland sparing radiotherapy technique using 3-D conformal radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lim, Ji Hoon; Kim, Gwi Eon; Keum, Ki Chang; Suh, Chang Ok; Lee, Sang Wook; Park, Hee Chul; Cho, Jae Ho; Chang, Sei Kyung; Loh, Juhn Kyu

    2000-01-01

    Although using the high energy photon beam with conventional parallel-opposed beams radio-therapy for nasopgaryngeal carcinoma, radiation-induced xerostomia is a troublesome problem for patients. We conducted this study to explore a new parotid gland sparing technique in 3-D conformal radiotherapy (3-DCRT) in an effort to prevent the radiation-induced xerostomia. We performed three different planning for four clinically node-negative nasopharyngeal cancer patients with different location of tumor(intracranial extension, nasal cavity extension, oropharyngeal extension, parapharyngeal extension), and intercompared the plans. Total prescription dose was 70.2 Gy to the isocenter. For plan-A, 2-D parallel opposing fields, a conventional radiotherapy technique, were employed. For plan-B, 2-D parallel opposing fields were used up until 54 Gy and afterwards 3-D non-coplanar beams were used. For plan-C, the new technique, 54Gy was delivered by 3-D conformal 3-port beams (AP and both lateral ports with wedge compensator, shielding both superficial lobes of parotid glands at the AP beam using BEV) from the beginning of the treatment and early spinal cord block (at 36 Gy) was performed. And bilateral posterior necks were treated with electron after 36 Gy. After 54 Gy, non-coplanar beams were used for cone-down plan. We intercompared dose statistics (Dmax, Dmin, Dmean, D95, D05, V95, V05, Volume receiving 46 Gy) and dose volume histograms (DVH) of tumor and normal tissues and NTCP values of parotid glands for the above three plans. For all patients, the new technique (plan-C) was comparable or superior to the other plans in target volume isodose distribution and dose statistics and it has more homogenous target volume coverage. The new technique was most superior to the other plans in parotid glands sparing (volume receiving 46 Gy: 100, 98, 69% for each plan-A, B and C). And it showed the lowest NTCP value of parotid glands in all patients (range of NTCP; 96-100%, 79-99%, 51

  5. Could 3-D conformal radiotherapy improve the overall survival for non-small cell lung cancer?

    International Nuclear Information System (INIS)

    Giraud, P.; Helfre, S.; Lavole, A.; Rosenwald, J.C.; Cosset, J.M.

    2002-01-01

    The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3-D treatment planning systems, sophisticated immobilization devices and demanding quality assurance and treatment verification. The main goal of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of healthy tissues. These techniques would then allow a further dose escalation increasing local control and survival. Non-small cell lung cancer (NSCLC) is one of the most difficult malignant tumors to be treated. It combines geometrical difficulties due to respiratory motion, and number of low tolerance neighboring organs, and dosimetric difficulties because of the presence of huge inhomogeneities. This localization is an attractive and ambitious example for the evaluation of new techniques. However, the published clinical reports in the last years described very heterogeneous techniques and, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from those conformal radiotherapy techniques. After reviewing the rationale for 3DCRT for NSCLC, this paper will describe the main studies of 3DCRT, in order to evaluate its impact on lung cancer treatment Then the current state-of-the-art of IMRT and the last technical and therapeutic innovations in NSCL will be discussed. (authors)

  6. Dosimetric comparison of standard three-dimensional conformal radiotherapy followed by intensity-modulated radiotherapy boost schedule (sequential IMRT plan) with simultaneous integrated boost-IMRT (SIB IMRT) treatment plan in patients with localized carcinoma prostate.

    Science.gov (United States)

    Bansal, A; Kapoor, R; Singh, S K; Kumar, N; Oinam, A S; Sharma, S C

    2012-07-01

    DOSIMETERIC AND RADIOBIOLOGICAL COMPARISON OF TWO RADIATION SCHEDULES IN LOCALIZED CARCINOMA PROSTATE: Standard Three-Dimensional Conformal Radiotherapy (3DCRT) followed by Intensity Modulated Radiotherapy (IMRT) boost (sequential-IMRT) with Simultaneous Integrated Boost IMRT (SIB-IMRT). Thirty patients were enrolled. In all, the target consisted of PTV P + SV (Prostate and seminal vesicles) and PTV LN (lymph nodes) where PTV refers to planning target volume and the critical structures included: bladder, rectum and small bowel. All patients were treated with sequential-IMRT plan, but for dosimetric comparison, SIB-IMRT plan was also created. The prescription dose to PTV P + SV was 74 Gy in both strategies but with different dose per fraction, however, the dose to PTV LN was 50 Gy delivered in 25 fractions over 5 weeks for sequential-IMRT and 54 Gy delivered in 27 fractions over 5.5 weeks for SIB-IMRT. The treatment plans were compared in terms of dose-volume histograms. Also, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) obtained with the two plans were compared. The volume of rectum receiving 70 Gy or more (V > 70 Gy) was reduced to 18.23% with SIB-IMRT from 22.81% with sequential-IMRT. SIB-IMRT reduced the mean doses to both bladder and rectum by 13% and 17%, respectively, as compared to sequential-IMRT. NTCP of 0.86 ± 0.75% and 0.01 ± 0.02% for the bladder, 5.87 ± 2.58% and 4.31 ± 2.61% for the rectum and 8.83 ± 7.08% and 8.25 ± 7.98% for the bowel was seen with sequential-IMRT and SIB-IMRT plans respectively. For equal PTV coverage, SIB-IMRT markedly reduced doses to critical structures, therefore should be considered as the strategy for dose escalation. SIB-IMRT achieves lesser NTCP than sequential-IMRT.

  7. Acute and late side-effects of conventional and conformal pelvic radiotherapy for cervical and endometrial cancer

    International Nuclear Information System (INIS)

    Izmajlowicz, B.; Komafel, J.

    2010-01-01

    Aim of the study. The purpose of this prospective study was to analyze and compare acute and late side-effects observed in patients with cervical and endometrial cancer treated with conventional 2-dimensional (2D) and conformal 3-dimensional (3D) pelvic radiotherapy. Patients and method. 50 patients treated with conventional pelvic radiotherapy and 50 patients treated with conformal pelvic radiotherapy at the Clinical Department of Gynecological Radiotherapy of the Lower Silesian Oncology Center between November 2004 and October 2005 were entered into a prospective study. We assessed Radiotherapy side-effects according to EORTCIRTOG, performance status according to the WHO, Body Mass Index and hematologic parameters during radiotherapy and one year after treatment. Results. Performance status acc. to the WHO was significantly better in the conformal arm. Anemia and nausea were more frequent in the conventional arm. In both the study groups acute gastrointestinal and genitourinary morbidity was more frequent than late morbidity and performance status was better after than before radiotherapy. Mean BMI was lower after radiotherapy than before treatment. Conclusions. Conformal pelvic radiotherapy in patients with cervical and endometrial cancer is less toxic than conventional pelvic radiotherapy which is also confirmed by the performance status. (authors)

  8. Conformity Index and Homogeneity Index of the Postoperative Whole Breast Radiotherapy.

    Science.gov (United States)

    Petrova, Deva; Smickovska, Snezana; Lazarevska, Emilija

    2017-10-15

    The treatment of breast cancer involves a multidisciplinary approach in which radiotherapy plays a key role. The conformity index and the homogeneity index are two analysis tools of a treatment plan using conformal radiotherapy. The purpose of this article is an analysis of these two parameters in the assessment of the treatment plans in 58 patients undergoing postoperative radiotherapy of the whole breast. All 58 patients participating in the study had a conservatively treated early-stage breast cancer. The treatment was performed using a standard regimen of fractionation in 25 fractions up to a total dose of 50 Gy. Dose-volume histograms were generated for both plans with and without segmental fields. Pair samples t-test was used. The technique with segmental fields allowed us more homogeneity distribution when compared to standard two tangential field techniques. The HI values were 1.08 ± 0.01 and 1.09 ± 0.01 for segment and technique with two tangential fields (p conformity and the homogeneity index are important tools in the analysis of the treatment plans during radiation therapy in patients with early-stage breast cancer. Adding segment fields in the administration of radiotherapy in patients with conservatively treated breast cancer can lead to improved dosage homogeneity and conformity.

  9. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1996-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  10. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1997-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  11. A Comparative Dosimetric Study of Adjuvant 3D Conformal Radiotherapy for Operable Stomach Cancer Versus AP-PA Conventional Radiotherapy in NCI-Cairo

    International Nuclear Information System (INIS)

    El-Hossiny, H.A.; Diab, N.A.; El-Taher, M.M.

    2009-01-01

    This study was to compare this multiple field conformal technique to the AP-PA technique with respect to target volume coverage and dose to normal tissues. Materials and Methods: Seventeen patients with stages II-III denocarcinoma of the stomach were treated with adjuvant postoperative chemoradiotherapy presented to radiotherapy department in National Cancer Institute, Cairo in period between February 2009 to March 2010 using 3D conformal radiotherapy technique that consisted of a mono isocentric arrangement employing 4-6 radiation fields. For each patient, a second radiotherapy treatment plan was done using an antroposterior (AP-PA) fields, the two techniques were then compared using dose volume histogram (DVH) analysis. Results: Comparing different DVHs, it was found that the planning target volume (PTV) was adequately covered in both (3D and 2D) plans while the left kidney and spinal cord demonstrate lower radiation doses on using the conformal technique. The liver doses is higher in the 3D tecq, but still well below liver tolerance. Conclusions: Both 3D conformal radiotherapy and AP-PA conventional techniques doses are within range of normal tissues tolerance. Regarding the left kidney and spinal cord the 3D conformal radiotherapy is superior than the AP-PA conventional techniques but with higher doses to the liver in the 3D conformal radiotherapy compared to the AP-PA conventional techniques

  12. Implementation of intensity-modulated conformational radiotherapy for cervical cancers at the Alexis Vautrin Centre

    International Nuclear Information System (INIS)

    Renard-Oldrini, Sophie

    2010-01-01

    As platinum salt based concomitant conformational radiotherapy and chemotherapy have been used as a standard treatment for cervical cancers but resulted in digestive and haematological toxicities, this research thesis reports the application of intensity-modulated conformational radiation therapy. After having recalled some epidemiological, anatomical aspects, diagnosis and treatments aspects regarding cervical cancer, the author presents this last treatment technique (principles, benefits, practical implementation). The author discusses results obtained by an experiment during which seven patients have been treated by simple conformational radiation therapy, and four by intensity-modulated conformational radiation therapy. Results are discussed in terms of volumes (clinical target volume, growth target volume, planned target volume), dosimetric results, toxicities (urine and skin), weight loss [fr

  13. Three dimensional conformal postoperative radiotherapy for ...

    African Journals Online (AJOL)

    Azza Helal

    2013-06-17

    Jun 17, 2013 ... during postoperative 3DCRT treatment of parotid gland cancer patients. ... contralateral parotid, oral cavity, cochlea, spinal cord, brain stem, eyes, lenses and ... xerostomia, dry ear, ear infections, hearing deficits and ipsilat-.

  14. Radiotherapy Treatment Planning for Testicular Seminoma

    International Nuclear Information System (INIS)

    Wilder, Richard B.; Buyyounouski, Mark K.; Efstathiou, Jason A.; Beard, Clair J.

    2012-01-01

    Virtually all patients with Stage I testicular seminoma are cured regardless of postorchiectomy management. For patients treated with adjuvant radiotherapy, late toxicity is a major concern. However, toxicity may be limited by radiotherapy techniques that minimize radiation exposure of healthy normal tissues. This article is an evidence-based review that provides radiotherapy treatment planning recommendations for testicular seminoma. The minority of Stage I patients who choose adjuvant treatment over surveillance may be considered for (1) para-aortic irradiation to 20 Gy in 10 fractions, or (2) carboplatin chemotherapy consisting of area under the curve, AUC = 7 × 1−2 cycles. Two-dimensional radiotherapy based on bony anatomy is a simple and effective treatment for Stage IIA or IIB testicular seminoma. Centers with expertise in vascular and nodal anatomy may consider use of anteroposterior–posteroanterior fields based on three-dimensional conformal radiotherapy instead. For modified dog-leg fields delivering 20 Gy in 10 fractions, clinical studies support placement of the inferior border at the top of the acetabulum. Clinical and nodal mapping studies support placement of the superior border of all radiotherapy fields at the top of the T12 vertebral body. For Stage IIA and IIB patients, an anteroposterior–posteroanterior boost is then delivered to the adenopathy with a 2-cm margin to the block edge. The boost dose consists of 10 Gy in 5 fractions for Stage IIA and 16 Gy in 8 fractions for Stage IIB. Alternatively, bleomycin, etoposide, and cisplatin chemotherapy for 3 cycles or etoposide and cisplatin chemotherapy for 4 cycles may be delivered to Stage IIA or IIB patients (e.g., if they have a horseshoe kidney, inflammatory bowel disease, or a history of radiotherapy).

  15. Radiotherapy Treatment Planning for Testicular Seminoma

    Energy Technology Data Exchange (ETDEWEB)

    Wilder, Richard B., E-mail: richardbwilder@yahoo.com [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL (United States); Buyyounouski, Mark K. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Efstathiou, Jason A. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Beard, Clair J. [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center, Boston, MA (United States)

    2012-07-15

    Virtually all patients with Stage I testicular seminoma are cured regardless of postorchiectomy management. For patients treated with adjuvant radiotherapy, late toxicity is a major concern. However, toxicity may be limited by radiotherapy techniques that minimize radiation exposure of healthy normal tissues. This article is an evidence-based review that provides radiotherapy treatment planning recommendations for testicular seminoma. The minority of Stage I patients who choose adjuvant treatment over surveillance may be considered for (1) para-aortic irradiation to 20 Gy in 10 fractions, or (2) carboplatin chemotherapy consisting of area under the curve, AUC = 7 Multiplication-Sign 1-2 cycles. Two-dimensional radiotherapy based on bony anatomy is a simple and effective treatment for Stage IIA or IIB testicular seminoma. Centers with expertise in vascular and nodal anatomy may consider use of anteroposterior-posteroanterior fields based on three-dimensional conformal radiotherapy instead. For modified dog-leg fields delivering 20 Gy in 10 fractions, clinical studies support placement of the inferior border at the top of the acetabulum. Clinical and nodal mapping studies support placement of the superior border of all radiotherapy fields at the top of the T12 vertebral body. For Stage IIA and IIB patients, an anteroposterior-posteroanterior boost is then delivered to the adenopathy with a 2-cm margin to the block edge. The boost dose consists of 10 Gy in 5 fractions for Stage IIA and 16 Gy in 8 fractions for Stage IIB. Alternatively, bleomycin, etoposide, and cisplatin chemotherapy for 3 cycles or etoposide and cisplatin chemotherapy for 4 cycles may be delivered to Stage IIA or IIB patients (e.g., if they have a horseshoe kidney, inflammatory bowel disease, or a history of radiotherapy).

  16. Chest wall desmoid tumours treated with definitive radiotherapy: a plan comparison of 3D conformal radiotherapy, intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy

    International Nuclear Information System (INIS)

    Liu, Jia; Ng, Diana; Lee, James; Stalley, Paul; Hong, Angela

    2016-01-01

    Definitive radiotherapy is often used for chest wall desmoid tumours due to size or anatomical location. The delivery of radiotherapy is challenging due to the large size and constraints of normal surrounding structures. We compared the dosimetry of 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) to evaluate the best treatment option. Ten consecutive patients with inoperable chest wall desmoid tumours (PTV range 416–4549 cm 3 ) were selected. For each patient, 3DCRT, IMRT and VMAT plans were generated and the Conformity Index (CI), organ at risk (OAR) doses and monitor unit (MU) were evaluated. The Wilcoxon signed-rank test was used to compare dose delivered to both target and OARs. The mean number of fields for 3DCRT and IMRT were 6.3 ± 2.1, 7.2 ± 1.8. The mean number of arcs for VMAT was 3.7 ± 1.1. The mean conformity index of VMAT (0.98 ± 0.14) was similar to that of IMRT (1.03 ± 0.13), both of which were significantly better than 3DCRT (1.35 ± 0.20; p = 0.005). The mean dose to lung was significantly higher for 3DCRT (11.9Gy ± 7.9) compared to IMRT (9.4Gy ± 5.4, p = 0.014) and VMAT (8.9Gy ± 4.5, p = 0.017). For the 3 females, the low dose regions in the ipsilateral breast for VMAT were generally less with VMAT. IMRT plans required 1427 ± 532 MU per fraction which was almost 4-fold higher than 3DCRT (313 ± 112, P = 0.005). Compared to IMRT, VMAT plans required 60 % less MU (570 ± 285, P = 0.005). For inoperable chest wall desmoid tumours, VMAT delivered equivalent target coverage when compared to IMRT but required 60 % less MU. Both VMAT and IMRT were superior to 3DCRT in terms of better PTV coverage and sparing of lung tissue

  17. Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality

    International Nuclear Information System (INIS)

    Ling, C. Clifton; Humm, John; Larson, Steven; Amols, Howard; Fuks, Zvi; Leibel, Steven; Koutcher, Jason A.

    2000-01-01

    Purpose: The goals of this study were to survey and summarize the advances in imaging that have potential applications in radiation oncology, and to explore the concept of integrating physical and biological conformality in multidimensional conformal radiotherapy (MD-CRT). Methods and Materials: The advances in three-dimensional conformal radiotherapy (3D-CRT) have greatly improved the physical conformality of treatment planning and delivery. The development of intensity-modulated radiotherapy (IMRT) has provided the 'dose painting' or 'dose sculpting' ability to further customize the delivered dose distribution. The improved capabilities of nuclear magnetic resonance imaging and spectroscopy, and of positron emission tomography, are beginning to provide physiological and functional information about the tumor and its surroundings. In addition, molecular imaging promises to reveal tumor biology at the genotype and phenotype level. These developments converge to provide significant opportunities for enhancing the success of radiotherapy. Results: The ability of IMRT to deliver nonuniform dose patterns by design brings to fore the question of how to 'dose paint' and 'dose sculpt', leading to the suggestion that 'biological' images may be of assistance. In contrast to the conventional radiological images that primarily provide anatomical information, biological images reveal metabolic, functional, physiological, genotypic, and phenotypic data. Important for radiotherapy, the new and noninvasive imaging methods may yield three-dimensional radiobiological information. Studies are urgently needed to identify genotypes and phenotypes that affect radiosensitivity, and to devise methods to image them noninvasively. Incremental to the concept of gross, clinical, and planning target volumes (GTV, CTV, and PTV), we propose the concept of 'biological target volume' (BTV) and hypothesize that BTV can be derived from biological images and that their use may incrementally improve

  18. Conformal radiotherapy by intensity modulation of pediatrics tumors

    International Nuclear Information System (INIS)

    Leseur, J.; Le Prise, E.; Carrie, C.; Bernier, V.; Beneyton, V.; Mahe, M.A.; Supiot, S.

    2009-01-01

    The objective of this study is to take stock on the validated and potential indications of the conformal radiotherapy with intensity modulation ( intensity modulated radiotherapy I.M.R.T.) in pediatrics and to propose recommendations for its use as well as the adapted dose constraints. About 40 to 50% of children treated for a cancer are irradiated. The I.M.R.T., by linear accelerator or helical tomo-therapy has for aim to give a homogenous dose to the target volume and to save organs at risk. Its use in pediatrics seems particularly interesting because of the complexity of target volumes and the closeness of organs at risk. In compensation for these positive elements, the importance of low doses irradiation given in big volumes makes fear event consequences on growth and an increased incidence of secondary cancers in children suffering from tumors with high cure rates and long life expectancy. (N.C.)

  19. Indications for quality assurance in conformal radiotherapy in Italy

    International Nuclear Information System (INIS)

    Banci Buonamici, F.; DE Angelis, C.; Rosi, A.; Tabocchini, M.A.; Iotti, C.; Olmi, P.

    2008-01-01

    Intensity-Modulated Radiation Therapy (IMRT) is an advanced and promising technique of external beam irradiation. IMRT is able to conform the dose distribution to the 3D tumour shape also for complex geometries, preserving surrounding normal tissues and reducing the probability of side effects. IMRT is a time consuming and complex technique and its use demands high level quality assurance. It is, therefore, very important to define conditions for its utilization. Professionals of Radiotherapy Centres, with experience in the IMRT use, have constituted a multidisciplinary working group with the aim of developing indications in this field. Purpose of the present document is to highlight relevant aspects of the technique, but also to underline the high complexity of the technique, whose implementation requires extreme attention of the staff of Radiotherapy Centres involved [it

  20. Accuracy requirements in radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Buzdar, S. A.; Afzal, M.; Nazir, A.; Gadhi, M. A.

    2013-01-01

    Radiation therapy attempts to deliver ionizing radiation to the tumour and can improve the survival chances and/or quality of life of patients. There are chances of errors and uncertainties in the entire process of radiotherapy that may affect the accuracy and precision of treatment management and decrease degree of conformation. All expected inaccuracies, like radiation dose determination, volume calculation, complete evaluation of the full extent of the tumour, biological behaviour of specific tumour types, organ motion during radiotherapy, imaging, biological/molecular uncertainties, sub-clinical diseases, microscopic spread of the disease, uncertainty in normal tissue responses and radiation morbidity need sound appreciation. Conformity can be increased by reduction of such inaccuracies. With the yearly increase in computing speed and advancement in other technologies the future will provide the opportunity to optimize a greater number of variables and reduce the errors in the treatment planning process. In multi-disciplined task of radiotherapy, efforts are needed to overcome the errors and uncertainty, not only by the physicists but also by radiologists, pathologists and oncologists to reduce molecular and biological uncertainties. The radiation therapy physics is advancing towards an optimal goal that is definitely to improve accuracy where necessary and to reduce uncertainty where possible. (author)

  1. Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer

    International Nuclear Information System (INIS)

    Ercan, T.; Alco, G.; Zengin, F.; Atilla, S.; Dincer, M.; Igdem, S.; Okkan, S.

    2010-01-01

    The aim of this study was to be able to implement the field-in-field intensity-modulated radiotherapy (FiF) technique in our daily practice for breast radiotherapy. To do this, we performed a dosimetric comparison. Treatment plans were produced for 20 consecutive patients. FiF plans and conformal radiotherapy (CRT) plans were compared for doses in the planning target volume (PTV), the dose homogeneity index (DHI), doses in irradiated soft tissue outside the target volume (SST), ipsilateral lung and heart doses for left breast irradiation, and the monitor unit counts (MU) required for treatment. Averaged values were compared using Student's t-test. With FiF, the DHI is improved 7.0% and 5.7%, respectively (P<0.0001) over the bilateral and lateral wedge CRT techniques. When the targeted volumes received 105% and 110% of the prescribed dose in the PTV were compared, significant decreases are found with the FiF technique. With the 105% dose, the SST, heart, and ipsilateral lung doses and the MU counts were also significantly lower with the FiF technique. The FiF technique, compared to CRT, for breast radiotherapy enables significantly better dose distribution in the PTV. Significant differences are also found for soft tissue volume, the ipsilateral lung dose, and the heart dose. Considering the decreased MUs needed for treatment, the FiF technique is preferred over tangential CRT. (author)

  2. Helical tomo-therapy in the anal canal cancer: dosimetric comparison with conformal radiotherapy with intensity modulation and classical conformal radiotherapy

    International Nuclear Information System (INIS)

    Ozsahin, M.; Ugurluer, G.; Ballerini, G.; Letenneur, G.; Zouhair, A.; Mirimanoff, R.O.

    2009-01-01

    A dosimetry comparison was made between helical tomo-therapy, I.M.R.T. and classical conformal three dimensional radiotherapy for twelve first patients that received a image guided radiotherapy, the toxicity was tackled with a minimum follow-up of fourteen months. In conclusion, the CT-guided radiotherapy allows to save organs at risks superior to I.M.R.T. and conformal radiotherapy and a best homogeneity in the target volume. the toxicity is moderated and the break time is limited. (N.C.)

  3. Dosimetric Study of Current Treatment Options for Radiotherapy in Retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Eldebawy, Eman [Department of Radiation Oncology, McGill University Health Centre, Montreal, Quebec (Canada); Department of Radiation Oncology, Children' s Cancer Hospital, Cairo (Egypt); Parker, William, E-mail: william.parker@mcgill.ca [Department of Medical Physics, McGill University Health Centre, Montreal, Quebec (Canada); Abdel Rahman, Wamied [Department of Medical Physics, McGill University Health Centre, Montreal, Quebec (Canada); Freeman, Carolyn R. [Department of Radiation Oncology, McGill University Health Centre, Montreal, Quebec (Canada)

    2012-03-01

    Purpose: To determine the best treatment technique for patients with retinoblastoma requiring radiotherapy to the whole eye. Methods and Materials: Treatment plans for 3 patients with retinoblastoma were developed using 10 radiotherapy techniques including electron beams, photon beam wedge pair (WP), photon beam three-dimensional conformal radiotherapy (3D-CRT), fixed gantry intensity-modulated radiotherapy (IMRT), photon volumetric arc therapy (VMAT), fractionated stereotactic radiotherapy, and helical tomotherapy (HT). Dose-volume analyses were carried out for each technique. Results: All techniques provided similar target coverage; conformity was highest for VMAT, nine-field (9F) IMRT, and HT (conformity index [CI] = 1.3) and lowest for the WP and two electron techniques (CI = 1.8). The electron techniques had the highest planning target volume dose gradient (131% of maximum dose received [D{sub max}]), and the CRT techniques had the lowest (103% D{sub max}) gradient. The volume receiving at least 20 Gy (V{sub 20Gy}) for the ipsilateral bony orbit was lowest for the VMAT and HT techniques (56%) and highest for the CRT techniques (90%). Generally, the electron beam techniques were superior in terms of brain sparing and delivered approximately one-third of the integral dose of the photon techniques. Conclusions: Inverse planned image-guided radiotherapy delivered using HT or VMAT gives better conformity index, improved orbital bone and brain sparing, and a lower integral dose than other techniques.

  4. Geometric accuracy of field alignment in fractionated stereotactic conformal radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Kortmann, Rolf D.; Becker, Gerd; Perelmouter, Jury; Buchgeister, Markus; Meisner, Christoph; Bamberg, Michael

    1999-01-01

    Purpose: To assess the accuracy of field alignment in patients undergoing three-dimensional (3D) conformal radiotherapy of brain tumors, and to evaluate the impact on the definition of planning target volume and control procedures. Methods and Materials: Geometric accuracy was analyzed in 20 patients undergoing fractionated stereotactic conformal radiotherapy for brain tumors. Rigid head fixation was achieved by using cast material. Transfer of stereotactic coordinates was performed by an external positioning device. The accuracy during treatment planning was quantitatively assessed by using repeated computed tomography (CT) examinations in treatment position (reproducibility of isocenter). Linear discrepancies were measured between treatment plan and CT examination. In addition, for each patient, a series of 20 verifications were taken in orthogonal projections. Linear discrepancies were measured between first and all subsequent verifications (accuracy during treatment delivery). Results: For the total group of patients, the distribution of deviations during treatment setup showed mean values between -0.3-1.2 mm, with standard deviations (SD) of 1.3-2.0 mm. During treatment delivery, the distribution of deviations revealed mean values between 0.7-0.8 mm, with SDs of 0.5-0.6 mm, respectively. For all patients, deviations for the transition to the treatment machine were similar to deviations during subsequent treatment delivery, with 95% of all absolute deviations between less than 2.8 and 4.6 mm. Conclusion: Random fluctuations of field displacements during treatment planning and delivery prevail. Therefore, our quantitative data should be considered when prescribing the safety margins of the planning target volume. Repeated CT examination are useful to detect operator errors and large random or systematic deviations before start of treatment. Control procedures during treatment delivery appear to be of limited importance. In addition, our findings should help to

  5. Daily-diary evaluated side-effects of conformal versus conventional prostatic cancer radiotherapy technique

    International Nuclear Information System (INIS)

    Widmark, A.; Fransson, P.; Franzen, L.; Littbrand, B.; Henriksson, R.

    1997-01-01

    Conventional 4-field box radiotherapy technique induces high morbidity for patients with localized prostatic cancer. Using a patient daily diary, the present study compared side-effects after conventional radiotherapy with conformal radiotherapy for prostate cancer. Fifty-eight patients treated with the conventional technique (with or without sucralfate) were compared with 72 patients treated with conformal technique. The patient groups were compared with an age-matched control population. Patients treated with conformal technique were also evaluated regarding acute and late urinary problems. Results showed that patients treated with conformal technique reported significantly fewer side-effects as compared with conventional technique. Patients treated with sucralfate also showed slightly decreased intestinal morbidity in comparison to non-sucralfate group. Acute and late morbidity evaluated by the patients was decreased after conformal radiotherapy as compared with the conventional technique. Sucralfate may be of value if conformal radiotherapy is used for dose escalation in prostatic cancer patients. (orig.)

  6. Salvage conformal radiotherapy for biochemical recurrent prostate cancer after radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Carlos R. Monti

    2006-08-01

    Full Text Available OBJECTIVE: Assess the results of salvage conformal radiotherapy in patients with biochemical failure after radical prostatectomy and identify prognostic factors for biochemical recurrence and toxicity of the treatment. MATERIALS AND METHODS: From June 1998 to November 2001, 35 patients were submitted to conformal radiotherapy for PSA > 0.2 ng/mL in progression after radical prostatectomy and were retrospectively analyzed. The mean dose of radiation in prostatic bed was of 77.4 Gy (68-81. Variables related to the treatment and to tumor were assessed to identify prognostic factors for biochemical recurrence after salvage radiotherapy. RESULTS: The median follow-up was of 55 months (17-83. The actuarial survival rates free of biochemical recurrence and free of metastasis at a distance of 5 years were 79.7% e 84.7%, respectively. The actuarial global survival rate in 5 years was 96.1%.The actuarial survival rate free of biochemical recurrence in 5 years was 83.3% with PSA pre-radiotherapy 1 and 2 (p = 0.023. Dose > 70 Gy in 30% of the bladder volume implied in more acute urinary toxicity (p = 0.035. The mean time for the development of late urinary toxicity was 21 months (12-51. Dose > 55 Gy in 50% bladder volume implied in more late urinary toxicity (p = 0.018. A patient presented late rectal toxicity of 2nd grade. CONCLUSIONS: Conformal radiotherapy showed to be effective for the control of biochemical recurrence after radical prostatectomy. Patients with pre-therapy PSA < 2 ng/mL have more biochemical control.

  7. Salvage conformal radiotherapy for biochemical recurrent prostate cancer after radical prostatectomy

    International Nuclear Information System (INIS)

    Monti, Carlos R.; Nakamura, Ricardo A.; Ferrigno, Robson; Rossi Junior, Aristides; Kawakami, Neusa S.; Trevisan, Felipe A.

    2006-01-01

    Objective: Assess the results of salvage conformal radiotherapy in patients with biochemical failure after radical prostatectomy and identify prognostic factors for biochemical recurrence and toxicity of the treatment. Materials and methods: From June 1998 to November 2001, 35 patients were submitted to conformal radiotherapy for PSA ≥ 0.2 ng/mL in progression after radical prostatectomy and were retrospectively analyzed. The mean dose of radiation in prostatic bed was of 77.4 Gy (68-81). Variables related to the treatment and to tumor were assessed to identify prognostic factors for biochemical recurrence after salvage radiotherapy. Results: The median follow-up was of 55 months (17-83). The actuarial survival rates free of biochemical recurrence and free of metastasis at a distance of 5 years were 79.7% e 84.7%, respectively. The actuarial global survival rate in 5 years was 96.1%.The actuarial survival rate free of biochemical recurrence in 5 years was 83.3% with PSA pre-radiotherapy ≤ 1, 100% when > 1 and ≤ 2, and 57.1% when > 2 (p = 0.023). Dose > 70 Gy in 30% of the bladder volume implied in more acute urinary toxicity (p = 0.035). The mean time for the development of late urinary toxicity was 21 months (12-51). Dose > 55 Gy in 50% bladder volume implied in more late urinary toxicity (p = 0.018). A patient presented late rectal toxicity of second grade. Conclusions: Conformal radiotherapy showed to be effective for the control of biochemical recurrence after radical prostatectomy. Patients with pre-therapy PSA < 2 ng/mL have more biochemical control. (author)

  8. Patient repositioning in prostate conformal radiotherapy by image fusion

    International Nuclear Information System (INIS)

    Betrouni, Nacim

    2004-01-01

    This research thesis first proposes an overview of imaging modalities which are generally used in radiotherapy, and briefly presents operation principles for ultrasound scans, scanners and MRI. The issue of patient repositioning in radiotherapy is then introduced, and already proposed solutions are presented. In the next part, the author addresses space location and ultrasound-based location, with a brief overview of methods used to track the displacements of a mobile object, in this case an ultrasound probe, and calibration. Then, after a presentation of the adopted method, and a discussion of published works related to contour extraction and to filtering and noise reduction methods in ultrasound imagery, the author addresses the issue of prostate segmentation based on ultrasound images. The next part deals with image registration with an overview of available methods and tools. A method of registration of pre-operation images obtained by MRI or scanner, and of intra-operation ultrasound images is proposed for a real-time registration. This method is aimed at supporting patient repositioning during prostate conformal radiotherapy

  9. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

    Science.gov (United States)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-02-27

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  10. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-01-01

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  11. Magnetic Resonance Imaging and conformal radiotherapy: Characterization of MRI alone simulation for conformal radiotherapy. Development and evaluation of an automatic volumes of interest segmentation tool for prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Pasquier, David

    2006-01-01

    Radiotherapy is a curative treatment of malignant tumours. Radiotherapy techniques considerably evolved last years with the increasing integration of medical images in conformal radiotherapy. This technique makes it possible to elaborate a complex ballistics conforming to target volume and sparing healthy tissues. The examination currently used to delineate volumes of interest is Computed Tomography (CT), on account of its geometrical precision and the information that it provides on electronic densities needed to dose calculation. Magnetic Resonance Imaging (MRI) ensures a more precise delineation of target volumes in many locations, such as pelvis and brain. For pelvic tumours, the use of MRI needs image registration, which complicates treatment planning and poses the problem of the lack of in vivo standard method of validation. The obstacles in the use of MRI alone in treatment planning were evaluated. Neither geometrical distortion linked with the system and the patient nor the lack of information on electronic densities represent stumbling obstacles. Distortion remained low even in edge of large field of view on modern machines. The assignment of electronic densities to bone structures and soft tissues in MR images permitted to obtain equivalent dosimetry to that carried out on the original CT, with a good reproducibility and homogeneous distribution within target volume. The assignment of electronic densities could not be carried out using 20 MV photons and suitable ballistics. The development of Image Guided Radiotherapy could facilitate the use of MRI alone in treatment planning. Target volumes and organ at risk delineation is a time consuming task in radiotherapy planning. We took part in the development and evaluated a method of automatic and semi automatic delineation of volumes of interest from MRI images for prostate cancer radiotherapy. For prostate and organ at risk automatic delineation an organ model-based method and a seeded region growing method

  12. Estimating the costs of intensity-modulated and 3-dimensional conformal radiotherapy in Ontario.

    Science.gov (United States)

    Yong, J H E; McGowan, T; Redmond-Misner, R; Beca, J; Warde, P; Gutierrez, E; Hoch, J S

    2016-06-01

    Radiotherapy is a common treatment for many cancers, but up-to-date estimates of the costs of radiotherapy are lacking. In the present study, we estimated the unit costs of intensity-modulated radiotherapy (imrt) and 3-dimensional conformal radiotherapy (3D-crt) in Ontario. An activity-based costing model was developed to estimate the costs of imrt and 3D-crt in prostate cancer. It included the costs of equipment, staff, and supporting infrastructure. The framework was subsequently adapted to estimate the costs of radiotherapy in breast cancer and head-and-neck cancer. We also tested various scenarios by varying the program maturity and the use of volumetric modulated arc therapy (vmat) alongside imrt. From the perspective of the health care system, treating prostate cancer with imrt and 3D-crt respectively cost $12,834 and $12,453 per patient. The cost of radiotherapy ranged from $5,270 to $14,155 and was sensitive to analytic perspective, radiation technique, and disease site. Cases of head-and-neck cancer were the most costly, being driven by treatment complexity and fractions per treatment. Although imrt was more costly than 3D-crt, its cost will likely decline over time as programs mature and vmat is incorporated. Our costing model can be modified to estimate the costs of 3D-crt and imrt for various disease sites and settings. The results demonstrate the important role of capital costs in studies of radiotherapy cost from a health system perspective, which our model can accommodate. In addition, our study established the need for future analyses of imrt cost to consider how vmat affects time consumption.

  13. Conformal radiotherapy using multileaf collimation: quality assurance and in vivo dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Aletti, P [Centre A. Vautrin, Nancy (France)

    1995-12-01

    The application of quality assurance principles in three dimensional conformal therapy is discussed.Critical requirements in three dimensional radiotherapy are the patient immobilization, the location, and the delivered dose. General recommendations with respect to the equipment for conformal radiotherapy and personnel are made.

  14. Conformal radiotherapy using multileaf collimation: quality assurance and in vivo dosimetry

    International Nuclear Information System (INIS)

    Aletti, P.

    1995-01-01

    The application of quality assurance principles in three dimensional conformal therapy is discussed.Critical requirements in three dimensional radiotherapy are the patient immobilization, the location, and the delivered dose. General recommendations with respect to the equipment for conformal radiotherapy and personnel are made

  15. Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy Strategies for Locally Advanced Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Uğur Selek

    2014-12-01

    Full Text Available Chemoradiotherapy is the current standard of care in patients with advanced inoperable stage IIIA or IIIB non-small cell lung cancer (NSCLC. Three-dimensional radiotherapy (3DCRT has been a trusted method for a long time and has well-known drawbacks, most of which could be improved by Intensity Modulated Radiotherapy (IMRT. IMRT is not currently the standard treatment of locally advanced NSCLC, but almost all patients could benefit to a degree in organ at risk sparing, dose coverage conformality, or dose escalation. The most critical step for a radiation oncology department is to strictly evaluate its own technical and physical capabilities to determine the ability of IMRT to deliver an optimal treatment plan. This includes calculating the internal tumor motion (ideally 4DCT or equivalent techniques, treatment planning software with an up-to-date heterogeneity correction algorithm, and daily image guidance. It is crucial to optimise and individualise the therapeutic ratio for each patient during the decision of 3DCRT versus IMRT. The current literature rationalises the increasing use of IMRT, including 4D imaging plus PET/CT, and encourages the applicable knowledge-based and individualised dose escalation using advanced daily image-guided radiotherapy.

  16. Fractionated stereotactic conformal radiotherapy following conservative surgery in the control of craniopharyngiomas

    International Nuclear Information System (INIS)

    Minniti, Giuseppe; Saran, Frank; Traish, Daphne; Soomal, Rubin; Sardell, Susan; Gonsalves, Adam; Ashley, Susan; Warrington, Jim; Burke, Kevin; Mosleh-Shirazi, Amin; Brada, Michael

    2007-01-01

    Purpose: To describe the technique and results of stereotactically guided conformal radiotherapy (SCRT) in patients with craniopharyngioma after conservative surgery. Methods and materials: Thirty-nine patients with craniopharyngioma aged 3-68 years (median age 18 years) were treated with SCRT between June 1994 and January 2003. All patients were referred for radiotherapy after undergoing one or more surgical procedures. Treatment was delivered in 30-33 daily fractions over 6-6.5 weeks to a total dose of 50 Gy using 6 MV photons. Outcome was assessed prospectively. Results: At a median follow-up of 40 months (range 3-88 months) the 3- and 5-year progression-free survival (PFS) was 97% and 92%, and 3- and 5-year survival 100%. Two patients required further debulking surgery for progressive disease 8 and 41 months after radiotherapy. Twelve patients (30%) had acute clinical deterioration due to cystic enlargement of craniopharyngioma following SCRT and required cyst aspiration. One patient with severe visual impairment prior to radiotherapy had visual deterioration following SCRT. Seven out of 10 patients with a normal pituitary function before SCRT had no endocrine deficits following treatment. Conclusion: SCRT as a high-precision technique of localized RT is suitable for the treatment of incompletely excised craniopharyngioma. The local control, toxicity and survival outcomes are comparable to results reported following conventional external beam RT. Longer follow-up is required to assess long-term efficacy and toxicity, particularly in terms of potential reduction in treatment related late toxicity

  17. High precision conformal radiotherapy employing conservative margins in childhood benign and low-grade brain tumours

    International Nuclear Information System (INIS)

    Jalali, Rakesh; Budrukkar, Ashwini; Sarin, Rajiv; Sharma, Dayananda S.

    2005-01-01

    Background and purpose: To report local control and follow up outcome data of high precision conformal radiotherapy in childhood brain tumours. Materials and methods: Between December 1999 and December 2002, 26 children (17 boys and 9 girls, median age 11.5 years) with incompletely excised or recurrent benign and low-grade brain tumours [13 craniopharyngiomas, 11 low-grade gliomas (LGG) and 2 others] were treated with three-dimensional (3D) conformal radiotherapy (CRT) (12 patients) and stereotactic conformal radiotherapy (SCRT) (14 patients). Gross tumour volume (GTV) included neuro-imaging based visible tumour and/or resected tumour bed. Clinical target volume (CTV) consisted of GTV + 5 mm margin and planning target volume (PTV) consisted of additional 5 mm margin for CRT and 2 mm for SCRT. Treatment was delivered with 3-9 conformal fixed fields to a median dose of 54 Gy/30 fractions. Results: The actuarial 2 and 3 year disease free and overall survival was 96 and 100%, respectively (median follow up: 25 months, range 12-47 months). Radiological follow up available in 25 patients revealed complete response in 1, partial regression in 10, stable disease in 13 and progression in 1 patient (within the CTV). One patient with craniopharyngioma on a routine imaging revealed a mild asymptomatic cyst enlargement, which resolved with conservative management. A patient with chiasmatic glioma developed cystic degeneration and hydrocephalus 9 months after SCRT requiring cyst drainage and placement of a ventriculoperitoneal shunt. Conclusion: High-precision conformal techniques delivering irradiation to a computer generated target volume employing 7-10 mm 3D margins beyond the visible tumour and/or resected tumour bed appear to be safe in children with incompletely resected or recurrent benign and low-grade brain tumours, based on these data

  18. A computer-controlled conformal radiotherapy system. IV: Electronic chart

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; McShan, Daniel L.; Matrone, Gwynne M.; Weaver, Tamar A.; Lewis, James D.; Kessler, Marc L.

    1995-01-01

    Purpose: The design and implementation of a system for electronically tracking relevant plan, prescription, and treatment data for computer-controlled conformal radiation therapy is described. Methods and Materials: The electronic charting system is implemented on a computer cluster coupled by high-speed networks to computer-controlled therapy machines. A methodical approach to the specification and design of an integrated solution has been used in developing the system. The electronic chart system is designed to allow identification and access of patient-specific data including treatment-planning data, treatment prescription information, and charting of doses. An in-house developed database system is used to provide an integrated approach to the database requirements of the design. A hierarchy of databases is used for both centralization and distribution of the treatment data for specific treatment machines. Results: The basic electronic database system has been implemented and has been in use since July 1993. The system has been used to download and manage treatment data on all patients treated on our first fully computer-controlled treatment machine. To date, electronic dose charting functions have not been fully implemented clinically, requiring the continued use of paper charting for dose tracking. Conclusions: The routine clinical application of complex computer-controlled conformal treatment procedures requires the management of large quantities of information for describing and tracking treatments. An integrated and comprehensive approach to this problem has led to a full electronic chart for conformal radiation therapy treatments

  19. Results of three-dimensional conformal radiotherapy and thalidomide for advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hsu, Wei-Chung; Chung, Na-Na; Wang, Po-Ming; Ying, Kung-Shih; Shin, Jeng-Shiann; Chao, Che-Jen; Lin, Gau-De; Chan, Sue-Ching; Ting, Lai-Lei

    2006-01-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional conformal radiotherapy and thalidomide in the treatment of advanced hepatocellular carcinoma. Between 1999 and 2003, 121 patients (mean age, 54.4±12.4 years; range, 20-81 years) with advanced hepatocellular carcinoma received three-dimensional conformal radiotherapy and thalidomide. Radiation was delivered in 1.5 Gy fractions twice daily for 5 days a week, for a total dose of 45-75 Gy. Mean treatment volume was 429.52±408.50 cm 3 (range, 26.89-2284.82 cm 3 ). Thalidomide was given concomitantly: 200 mg/day in 109 patients, 300 mg/day in 8 patients and 400 mg/day in 4 patients. Treatment responses, survival rates and factors affecting survival were analyzed. Treatment responses were observed in 61% of the patients. Liver cirrhosis (P=0.001) and tumor size (P=0.001) significantly affected the tumor responses. Overall survival at 6, 12 and 24 months was 84.8, 60.0 and 44.6%, respectively. On univariate analysis, liver cirrhosis (P=0.003), Karnofsky performance status (P=0.007), tumor size (P<0.001), portal vein tumor thrombosis (P<0.001) and alpha-fetoprotein level (P=0.003) were shown to significantly affect survival. On multivariate analysis, only thrombosis (P=0.039) and alpha-fetoprotein level (P=0.006) were shown to be factors affecting survival. Three-dimensional conformal radiotherapy with thalidomide seems to be effective in the treatment of advanced hepatocellular carcinoma. (author)

  20. Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine

    International Nuclear Information System (INIS)

    Bannach, B.; Doll, Th.; Pape, H.; Schmitt, G.

    1995-01-01

    The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning size, position and contour to PTV-projection in beams-eye-view (BEV). Field prescription with defined leaf positions of the MLC-setting for geometrical beam shaping is transferred from TPS via TCP/IP. Patient treatment with complex coplanar and non-coplanar field arrangements is performed with an automatic set-up for gantry and collimator angle position contolled by a verification system. Quality assurance for treatment set-up is gained with a mega-voltage imaging device (MVI / PHILIPS SRI 100). Actual treatment outcome and accurate dose delivery for conformal therapy is verified by intercomparison of geometrical field matching of MVI and digitally reconstructed radiographs (DRR) for each delivered beam in BEV

  1. Evaluation of conformal radiotherapy techniques through physics and biologic criteria

    International Nuclear Information System (INIS)

    Bloch, Jonatas Carrero

    2012-01-01

    In the fight against cancer, different irradiation techniques have been developed based on technological advances and aiming to optimize the elimination of tumor cells with the lowest damage to healthy tissues. The radiotherapy planning goal is to establish irradiation technical parameters in order to achieve the prescribed dose distribution over the treatment volumes. While dose prescription is based on radiosensitivity of the irradiated tissues, the physical calculations on treatment planning take into account dosimetric parameters related to the radiation beam and the physical characteristics of the irradiated tissues. To incorporate tissue's radiosensitivity into radiotherapy planning calculations can help particularize treatments and establish criteria to compare and elect radiation techniques, contributing to the tumor control and the success of the treatment. Accordingly, biological models of cellular response to radiation have to be well established. This work aimed to study the applicability of using biological models in radiotherapy planning calculations to aid evaluating radiotherapy techniques. Tumor control probability (TCP) was studied for two formulations of the linear-quadratic model, with and without repopulation, as a function of planning parameters, as dose per fraction, and of radiobiological parameters, as the α/β ratio. Besides, the usage of biological criteria to compare radiotherapy techniques was tested using a prostate planning simulated with Monte Carlo code PENELOPE. Afterwards, prostate planning for five patients from the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, USP, using three different techniques were compared using the tumor control probability. In that order, dose matrices from the XiO treatment planning system were converted to TCP distributions and TCP-volume histograms. The studies performed allow the conclusions that radiobiological parameters can significantly influence tumor control

  2. Conventional and conformal technique of external beam radiotherapy in locally advanced cervical cancer: Dose distribution, tumor response, and side effects

    Science.gov (United States)

    Mutrikah, N.; Winarno, H.; Amalia, T.; Djakaria, M.

    2017-08-01

    The objective of this study was to compare conventional and conformal techniques of external beam radiotherapy (EBRT) in terms of the dose distribution, tumor response, and side effects in the treatment of locally advanced cervical cancer patients. A retrospective cohort study was conducted on cervical cancer patients who underwent EBRT before brachytherapy in the Radiotherapy Department of Cipto Mangunkusumo Hospital. The prescribed dose distribution, tumor response, and acute side effects of EBRT using conventional and conformal techniques were investigated. In total, 51 patients who underwent EBRT using conventional techniques (25 cases using Cobalt-60 and 26 cases using a linear accelerator (LINAC)) and 29 patients who underwent EBRT using conformal techniques were included in the study. The distribution of the prescribed dose in the target had an impact on the patient’s final response to EBRT. The complete response rate of patients to conformal techniques was significantly greater (58%) than that of patients to conventional techniques (42%). No severe acute local side effects were seen in any of the patients (Radiation Therapy Oncology Group (RTOG) grades 3-4). The distribution of the dose and volume to the gastrointestinal tract affected the proportion of mild acute side effects (RTOG grades 1-2). The urinary bladder was significantly greater using conventional techniques (Cobalt-60/LINAC) than using conformal techniques at 72% and 78% compared to 28% and 22%, respectively. The use of conformal techniques in pelvic radiation therapy is suggested in radiotherapy centers with CT simulators and 3D Radiotherapy Treatment Planning Systems (RTPSs) to decrease some uncertainties in radiotherapy planning. The use of AP/PA pelvic radiation techniques with Cobalt-60 should be limited in body thicknesses equal to or less than 18 cm. When using conformal techniques, delineation should be applied in the small bowel, as it is considered a critical organ according to RTOG

  3. Estimate of the damage in organs induced by neutrons in three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Benites R, J. L.; Vega C, H. R.; Uribe, M. del R.

    2014-08-01

    By means of Monte Carlo methods was considered the damage in the organs, induced by neutrons, of patients with cancer that receive treatment in modality of three-dimensional conformal radiotherapy (3D-CRT) with lineal accelerator Varian Ix. The objective of this work was to estimate the damage probability in radiotherapy patients, starting from the effective dose by neutrons in the organs and tissues out of the treatment region. For that a three-dimensional mannequin of equivalent tissue of 30 x 100 x 30 cm 3 was modeled and spherical cells were distributed to estimate the Kerma in equivalent tissue and the absorbed dose by neutrons. With the absorbed dose the effective dose was calculated using the weighting factors for the organ type and radiation type. With the effective dose and the damage factors, considered in the ICRP 103, was considered the probability of damage induction in organs. (Author)

  4. Conformal radiotherapy of locally advanced bile duct carcinoma

    International Nuclear Information System (INIS)

    Bouras, N.; Caudry, M.; Bonnel, C.; Trouette, R.; Demeaux, H.; Maire, J.P.; Saric, J.; Rullier, E.

    2002-01-01

    Purpose. - Retrospective study of 23 patients treated with conformal radiotherapy for a locally advanced bile duct carcinoma. Patients and methods. - Eight cases were irradiated after a radical resection (RO), because they were N+; seven after microscopically incomplete resection (R1) ; seven were not resected (R2). A dose of 45 of 50 Gy was delivered, followed by a boost up to 60 Gy in R1 and R2 groups. Concomitant chemotherapy was given in 15 cases. Results.-Late toxicity included a stenosis of the duodenum, and one of the biliary anastomosis. Two patients died from cholangitis, the mechanism of which remains unclear. Five patients are in complete remission, six had a local relapse, four developed a peritoneal carcinosis, and six distant metastases. Actuarial survival rate is 75%, 28% and 7% at 1, 3 and 5 years, respectively (median: 16.5 months). Seven patients are still alive with a 4 to 70 months follow-up. Survival is similar in the 3 small subgroups. The poor local control among RON+ cases might be related to the absence of a boost to the 'tumor bed'. In R1 patients, relapses were mainly distant metastases, where'as local and peritoneal recurrences predominated in R2. Conclusion. - Conformal radio-chemotherapy delivering 60 Gy represents a valuable palliative approach in locally advanced biliary carcinoma. (authors)

  5. Phase I study of conformal radiotherapy with concurrent gemcitabine in locally advanced bladder cancer

    International Nuclear Information System (INIS)

    Sangar, Vijay K.; McBain, Catherine A.; Lyons, Jeanette; Ramani, Vijay; Logue, John; Wylie, James; Clarke, Noel W.; Cowan, Richard A.

    2005-01-01

    Purpose: A prospective phase I trial was conducted to determine the maximal tolerated dose of gemcitabine given once weekly during hypofractionated conformal radiotherapy to patients with locally advanced transitional cell carcinoma of the bladder. Eight male patients, median age 69 years, with Stage T2 (n = 4) or T3 (n = 4) N0M0, were enrolled in cohorts of 3. Treatment comprised conformal radiotherapy (52.5 Gy in 20 fractions) within 4 weeks, with concurrent gemcitabine once weekly for four cycles. The weekly gemcitabine dose was escalated from 100 mg/m 2 in increments of 50 mg/m 2 per cohort. Dose-limiting toxicity was defined as any acute Radiation Therapy Oncology Group (RTOG) toxicity Grade 3 or greater arising in >1 of 3 patients in each cohort. Tumor response was assessed cystoscopically and radiologically at 3 months. Results: All 8 patients completed radiotherapy, and 6 of 8 completed chemoradiotherapy. No acute toxicity greater than RTOG Grade 1 was seen with gemcitabine at 100 mg/m 2 . Dose-limiting toxicity was observed at 150 mg/m 2 with Grade 3 toxicity seen in 2 of 2 patients (one bladder, one bowel). An additional 3 patients received 100 mg/m 2 with minimal toxicity. No hematologic toxicity was encountered. A complete response was seen in 7 (87.5%) of 8 patients, all of whom were disease free at a median follow-up of 19.5 months (range, 14-23 months). No late toxicity (greater than RTOG Grade 0) has been observed. Conclusion: The maximal tolerated dose for gemcitabine given once weekly with concurrent hypofractionated conformal bladder radiotherapy was 150 mg/m 2 , with a maximal recommended dose of 100 mg/m 2 . This dose regimen has now entered Phase II clinical trials

  6. Preservation of parotid function with uncomplicated conformal radiotherapy

    International Nuclear Information System (INIS)

    Maes, Annelies; Weltens, Caroline; Flamen, Patrick; Lambin, Philippe; Bogaerts, Ria; Liu, Xuan; Baetens, Jan; Hermans, Robert; Van den Bogaert, Walter

    2002-01-01

    Background and purpose: To evaluate (1) parotid function, (2) subjective xerostomia and (3) pattern of relapses after conformal parotid-sparing radiotherapy (RT) for head and neck cancer. (4) To study dose-response curves of parotid glands. Material and methods: From September 1999 to November 2000, 39 head and neck cancer patients requiring bilateral neck RT were treated with a fairly simple conformal RT technique (three-field set-up+anterior lower neck field; two opposed oblique boost fields). The contralateral parotid was spared. Parotid function was assessed by salivary gland scintigraphies performed before, early (median 4 weeks) and late (median 28 weeks) after RT. Xerostomia was monitored by visual analogue scales (VAS) and LENT SOMA scores. Location of locoregional recurrences was studied in relation to the radiation fields. A dose-response curve of parotids was created using logistic regression. Results: (1) Early after RT, on salivary gland scintigraphy, the mean loss of secretion function in the spared parotid was 67% and total in the non-spared. Late after RT, the mean loss remained 19% in the spared and total in the non-spared parotid. Normal excretion function was regained in 75% of the spared parotids. (2) Late after RT, 78% of patients had no, minimal or acceptable subjective xerostomia. (3) No recurrence was seen near the spared parotid (11/39 locoregional recurrences). (4) The dose-response curve of parotids showed that the mean parotid dose should preferentially be ≤20 Gy, to obtain a good chance (≥70%) for preservation of its function on scintigraphy. Conclusions: An easy conformal parotid-sparing RT technique prevents moderate or severe subjective xerostomia in 78% of patients. In the spared parotids, nearly complete to complete recovery is obtained after 6-12 months

  7. Conformal fields in prostate radiotherapy: A comparison between measurement, calculation and simulation

    Directory of Open Access Journals (Sweden)

    Seied R Mahdavi

    2012-01-01

    Full Text Available Aims: The objective of this study is to evaluate the accuracy of a treatment planning system (TPS for calculating the dose distribution parameters in conformal fields (CF. Dosimetric parameters of CF′s were compared between measurement, Monte Carlo simulation (MCNP4C and TPS calculation. Materials and Methods: Field analyzer water phantom was used for obtaining percentage depth dose (PDD curves and beam profiles (BP of different conformal fields. MCNP4C was used to model conformal fields dose specification factors and head of linear accelerator varian model 2100C/D. Results: Results showed that the distance to agreement (DTA and dose difference (DD of our findings were well within the acceptance criteria of 3 mm and 3%, respectively. Conclusions: According to this study it can be revealed that TPS using equivalent tissue air ratio calculation method is still convenient for dose prediction in non small conformal fields normally used in prostate radiotherapy. It was also showed that, since there is a close correlation with Monte Carlo simulation, measurements and TPS, Monte Carlo can be further confirmed for implementation and calculation dose distribution in non standard and complex conformal irradiation field for treatment planning systems.

  8. Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Hamilton, Russell J.; Kuchnir, Franca T.; Sweeney, Patrick; Rubin, Steven J.; Dujovny, Manuel; Pelizzari, Charles A.; Chen, George T. Y.

    1995-01-01

    Purpose: Compare the use of static conformal fields with the use of multiple noncoplanar arcs for stereotactic radiosurgery or stereotactic radiotherapy treatment of intracranial lesions. Evaluate the efficacy of these treatment techniques to deliver dose distributions comparable to those considered acceptable in current radiotherapy practice. Methods and Materials: A previously treated radiosurgery case of a patient presenting with an irregularly shaped intracranial lesion was selected. Using a three-dimensional (3D) treatment-planning system, treatment plans using a single isocenter multiple noncoplanar arc technique and multiple noncoplanar conformal static fields were generated. Isodose distributions and dose volume histograms (DVHs) were computed for each treatment plan. We required that the 80% (of maximum dose) isodose surface enclose the target volume for all treatment plans. The prescription isodose was set equal to the minimum target isodose. The DVHs were analyzed to evaluate and compare the different treatment plans. Results: The dose distribution in the target volume becomes more uniform as the number of conformal fields increases. The volume of normal tissue receiving low doses (> 10% of prescription isodose) increases as the number of static fields increases. The single isocenter multiple arc plan treats the greatest volume of normal tissue to low doses, approximately 1.6 times more volume than that treated by four static fields. The volume of normal tissue receiving high (> 90% of prescription isodose) and intermediate (> 50% of prescription isodose) doses decreases by 29 and 22%, respectively, as the number of static fields is increased from four to eight. Increasing the number of static fields to 12 only further reduces the high and intermediate dose volumes by 10 and 6%, respectively. The volume receiving the prescription dose is more than 3.5 times larger than the target volume for all treatment plans. Conclusions: Use of a multiple noncoplanar

  9. An ill-conditioning conformal radiotherapy analysis based on singular values decomposition

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Grandjean, P.; Bendada, S.; Dominique, C.; Platoni, K.; Schlienger, M.

    1995-01-01

    Clinical experience in stereotactic radiotherapy of irregular complex lesions had shown that optimization algorithms were necessary to improve the dose distribution. We have developed a general optimization procedure which can be applied to different conformal irradiation techniques. In this presentation this procedure is tested on the stereotactic radiotherapy modality of complex cerebral lesions treated with multi-isocentric technique based on the 'associated targets methodology'. In this inverse procedure we use the singular value decomposition (SVD) analysis which proposes several optimal solutions for the narrow beams weights of each isocentre. The SVD analysis quantifies the ill-conditioning of the dosimetric calculation of the stereotactic irradiation, using the condition number which is the ratio of the bigger to smaller singular values. Our dose distribution optimization approach consists on the study of the irradiation parameters influence on the stereotactic radiotherapy inverse problem. The adjustment of the different irradiation parameters into the 'SVD optimizer' procedure is realized taking into account the ratio of the quality reconstruction to the time calculation. It will permit a more efficient use of the 'SVD optimizer' in clinical applications for real 3D lesions. The evaluation criteria for the choice of satisfactory solutions are based on the dose-volume histograms and clinical considerations. We will present the efficiency of ''SVD optimizer'' to analyze and predict the ill-conditioning in stereotactic radiotherapy and to recognize the topography of the different beams in order to create optimal reconstructed weighting vector. The planification of stereotactic treatments using the ''SVD optimizer'' is examined for mono-isocentrically and complex dual-isocentrically treated lesions. The application of the SVD optimization technique provides conformal dose distribution for complex intracranial lesions. It is a general optimization procedure

  10. Monte Carlo conformal treatment planning as an independent assessment

    International Nuclear Information System (INIS)

    Rincon, M.; Leal, A.; Perucha, M.; Carrasco, E.; Sanchez-Doblado, F.; Hospital Univ. Virgen Macarena, Sevilla; Arrans, R.; Sanchez-Calzado, J.A.; Errazquin, L.; Medrano, J.C.

    2001-01-01

    The wide range of possibilities available in Radiotherapy with conformal fields cannot be covered experimentally. For this reason, dosimetrical and planning procedures are based on approximate algorithms or systematic measurements. Dose distribution calculations based on Monte Carlo (MC) simulations can be used to check results. In this work, two examples of conformal field treatments are shown: A prostate carcinoma and an ocular lymphoma. The dose distributions obtained with a conventional Planning System and with MC have been compared. Some significant differences have been found. (orig.)

  11. Dosimetric comparison of three-dimensional conformal and intensity modulated radiotherapy in brain glioma

    International Nuclear Information System (INIS)

    Lu Jie; Zhang Guifang; Bai Tong; Yin Yong; Fan Tingyong; Wu Chaoxia

    2009-01-01

    Objective: To investigate the dosimetry advantages of intensity modulated radiotherapy (IMRT)of brain glioma compared with that of three-dimensional conformal radiotherapy (SD CRT). Methods: Ten patients with brain glioma were enrolled in this study. Three-dimensional conf0rmal and intensity modulated radiotherapy plans were performed for each patient. The dose distributions of target volume and normal tissues, conformal index (CI) and heterogeneous index (HI) were analyzed using the dose-volume histogram (DVH). The prescription dose was 60 Gy in 30 fractions. Results: IMRT plans decrease the maximum dose and volume of brainstem, mean dose of affected side parotid and maximum dose of spinal-cord. The CI for PTV of IMRT was superior to that of SD CRT, the HI for PTV has no statistical significance of the two model plans. Conclusions: IMRT plans can obviously decrease the dose and volume of brainstem. IMRT is a potential method in the treatment of brain glioma, and dose escalation was possible in patients with brain glioma. (authors)

  12. Tolerance and early outcome results of postprostatectomy three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Aschkenasy, Eric; Kelsen, Suzanne; Leibel, Steven A.

    1997-01-01

    Purpose: Three-dimensional conformal radiotherapy (3D-CRT) has been associated with a reduction in acute and late toxicity among patients treated for localized prostatic cancer. The purpose of this study is to assess the acute and late toxicity of 3D-CRT delivered to patients in the postprostatectomy setting and to analyze which factors predict for durable biochemical control in this group of patients. Methods and Materials: Between 1988 and 1994, 42 patients were treated after prostatectomy with three-dimensional conformal radiotherapy. The median time from prostatectomy to radiotherapy was 11 months. Indications for treatment included a rising serum PSA level in 28 patients (65%) and positive surgical margins without a rising PSA level in 14 (35%). Twenty-five patients (60%) had pathologic stage T3 disease, and 32 (74%) had tumor at or close to the surgical margins. The median dose was 64.8 Gy, and the median follow-up time was 2 years. Results: 3D-CRT in the postprostatectomy setting was well tolerated. Three patients (7%) experienced Grade II acute genitourinary toxicity and nine patients (21%) experienced Grade II acute gastrointestinal toxicity during treatment. No patient experienced Grade III or higher acute morbidity. The 2-year actuarial risk for Grade II late genitourinary and gastrointestinal late complications were 5 and 9%, respectively. In patients with existing incontinence, the incidence of worsening stress incontinence 6 months after treatment was 17%, which resolved within 12 months to its preradiotherapy level in four of six cases (66%). The overall 2-year postirradiation PSA relapse-free survival rate was 53%. The 2-year PSA relapse-free survival was 66% for patients with undetectable PSA levels in the immediate postoperative period compared to 26% for those with detectable levels of PSA after surgery (p 1.0 ng/ml (p 1 ng/ml (p < 0.002) was the most important covariate predicting for a rising PSA after radiotherapy. Conclusions: After

  13. Induction therapy with carboplatin/paclitaxel followed by concurrent carboplatin/paclitaxel and dose-escalating conformal radiotherapy in the treatment of locally advanced, unresectable non-small cell lung cancer: preliminary report of a phase I trial.

    Science.gov (United States)

    Socinski, M A; Clark, J A; Halle, J; Steagall, A; Kaluzny, B; Rosenman, J G

    1997-08-01

    Locally advanced non-small cell lung cancer is optimally managed with chemotherapy and thoracic irradiation, although the most appropriate strategy is not yet defined. In this phase I trial, we use two 21-day cycles of induction chemotherapy with paclitaxel (Taxol; Bristol-Myers Squibb Company, Princeton, NJ) (225 mg/m2 over 3 hours) and carboplatin (area under the concentration-time curve = 6) followed by concurrent weekly paclitaxel (45 mg/m2/wk x 6) and carboplatin (area under the concentration-time curve = 2/wk x 6) and thoracic irradiation. Patients undergo three-dimensional treatment planning (conformal radiotherapy) to define the cancer target volume precisely. The phase I question being addressed in this study is the maximum tolerated radiation dose given concurrently with low-dose paclitaxel and carboplatin. The initial radiation dose is 60 Gy, with dose escalations to 66 Gy, 70 Gy, and 74 Gy being planned. Ten patients have been entered thus far (eight men and two women). Their median age is 67 years (range, 59 to 78 years), and none of the patients has had greater than 5% pretreatment weight loss. Seven of 10 are evaluable for response to induction carboplatin and paclitaxel, with a response rate of 57% (three partial responses and one minor response). Three patients had stable disease and none of the patients had evidence of progressive disease during induction chemotherapy. Three patients have completed all treatment at 60 Gy and one has completed all treatment at 66 Gy. Three of the four patients have had partial responses (75%), with the remaining patient having stable disease. Toxicity in the concurrent chemoradiotherapy portion of the trial thus far has consisted of grade 3 neutropenia in one patient and grade 4 lymphocytopenia in all four patients. No grade 3 or 4 nonhematologic toxicity has been seen. The trial data are not yet mature enough to report on survival. Accrual and treatment is continuing at the 66 Gy radiation dose level.

  14. Applications of three-dimensional image correlation in conformal radiotherapy

    International Nuclear Information System (INIS)

    Van Herk, M.; Gilhuijs, K.; Kwa, S.; Lebesque, J.; Muller, S.; De Munck, J.; Touw, A.; Kooy, H.

    1995-01-01

    The development of techniques for the registration of CT, MRI and SPECT creates new possibilities for improved target volume definition and quantitative image analysis. The discussed technique is based on chamfer matching and is suitable for automatic 3-D matching of CT with CT, CT with MRI, CT with SPECT and MRI with SPECT. By integrating CT with MRI, the diagnostic qualities of MRI are combined with the geometric accuracy of the planning CT. Significant differences in the delineation of the target volume for brain, head and neck and prostate tumors have been demonstrated when using integrated CT and MRI compared with using CT alone. In addition, integration of the planning CT with pre-operative scans improves knowledge of possible tumor extents. By first matching scans based on the bony anatomy and subsequently matching on an organ of study, relative motion of the organ is quantified accurately. In a study with 42 CT scans of 11 patients, magnitude and causes of prostate motion have been analysed. The most important motion of the prostate is a forward-backward rotation around a point near the apex caused by rectal volume difference. Significant correlations were also found between motion of the legs and the prostate. By integrating functional images made before and after radiotherapy with the planning CT, the relation between local change of lung function and delivered dose has been quantified accurately. The technique of chamfer matching is a convenient and more accurate alternative for the use of external markers in a CT/SPECT lung damage study. Also, damage visible in diagnostic scans can be related to radiation dose, thereby improving follow-up diagnostics. It can be concluded that 3-D image integration plays an important role in assessing and improving the accuracy of radiotherapy and is therefore indispensable for conformal therapy. However, user-friendly implementation of these techniques remains to be done to facilitate clinical application on a large

  15. Applications of three-dimensional image correlation in conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Van Herk, M; Gilhuijs, K; Kwa, S; Lebesque, J; Muller, S; De Munck, J; Touw, A [Nederlands Kanker Inst. ` Antoni van Leeuwenhoekhuis` , Amsterdam (Netherlands); Kooy, H [Harvard Medical School, Boston, MA (United States)

    1995-12-01

    The development of techniques for the registration of CT, MRI and SPECT creates new possibilities for improved target volume definition and quantitative image analysis. The discussed technique is based on chamfer matching and is suitable for automatic 3-D matching of CT with CT, CT with MRI, CT with SPECT and MRI with SPECT. By integrating CT with MRI, the diagnostic qualities of MRI are combined with the geometric accuracy of the planning CT. Significant differences in the delineation of the target volume for brain, head and neck and prostate tumors were demonstrated when using integrated CT and MRI compared with using CT alone. In addition, integration of the planning CT with pre-operative scans improves knowledge of possible tumor extents. By first matching scans based on the bony anatomy and subsequently matching on an organ of study, relative motion of the organ is quantified accurately. In a study with 42 CT scans of 11 patients, magnitude and causes of prostate motion were analysed. The most important motion of the prostate is a forward-backward rotation around a point near the apex caused by rectal volume difference. Significant correlations were also found between motion of the legs and the prostate. By integrating functional images made before and after radiotherapy with the planning CT, the relation between local change of lung function and delivered dose has been quantified accurately. The technique of chamfer matching is a convenient and more accurate alternative for the use of external markers in a CT/SPECT lung damage study. Also, damage visible in diagnostic scans can be related to radiation dose, thereby improving follow-up diagnostics. It can be concluded that 3-D image integration plays an important role in assessing and improving the accuracy of radiotherapy and is therefore indispensable for conformal therapy. However, user-friendly implementation of these techniques remains to be done to facilitate clinical application on a large scale.

  16. Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Crowe, Scott B [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia); Kairn, Tanya [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia); Premion, Wesley Medical Centre, Brisbane, Queensland (Australia); Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T [Premion, Wesley Medical Centre, Brisbane, Queensland (Australia); Kenny, John [Australian Clinical Dosimetry Services, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Victoria (Australia); Langton, Christian M; Trapp, Jamie V [Science and Engineering Faculty, Queensland University of Technology, Brisbane, Queensland (Australia)

    2013-12-15

    This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

  17. Doses to organs at cerebral risks: optimization by robotized stereotaxic radiotherapy and automatic segmentation atlas versus three dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Bondiau, P.Y.; Thariat, J.; Benezery, K.; Herault, J.; Dalmasso, C.; Marcie, S.; Malandain, G.

    2007-01-01

    The stereotaxic radiotherapy robotized by 'Cyberknife fourth generation' allows a dosimetric optimization with a high conformity index on the tumor and radiation doses limited on organs at risk. A cerebral automatic anatomic segmentation atlas of organs at risk are used in routine in three dimensions. This study evaluated the superiority of the stereotaxic radiotherapy in comparison with the three dimensional conformal radiotherapy on the preservation of organs at risk in regard of the delivered dose to tumors justifying an accelerated hypo fractionation and a dose escalation. This automatic segmentation atlas should allow to establish correlations between anatomy and cerebral dosimetry; This atlas allows to underline the dosimetry optimization by stereotaxic radiotherapy robotized for organs at risk. (N.C.)

  18. Three dimensional-conformal radiotherapy combined with capecitabine chemotherapy for locally advanced (unresectable) rectal cancer

    International Nuclear Information System (INIS)

    Zhu Yaqun; Tian Ye; Zhang Junning; Wang Bin

    2010-01-01

    Objective: To evaluate the compliance and efficacy of chemoradiotherapy for locally advanced (unresectable) rectal cancer. Methods: Thirty eight patients with locally advanced (T4 or recurred) rectal cancer received three dimensional-conformal radiotherapy (for 46 ∼ 50Gy/5 weeks and was boosted to the tumor 16 ∼ 18Gy/2 weeks, 2Gy/fraction, 5 days/week) in combination with capecitabine 1 650mg · m -2 · d -1 , day 1-14, every 3 weeks. Results: The overall response rate was 57.9%, with CR 5 (13.2%), PR 17(44.7%), SD 10 (26.3%), PD 6 (15.8%), median survival time, the 1-year overall survival rate and the 2-year overall survival rate were 18 months, 64.43%, 18.78%, respectively. The remission rate of pain and improvement rate of performance status were 100% and 52.8%. Treatment-related toxicity mainly showed at diarrhea, neutrocytopenia and hand-foot syndrome, the incidence of grade 3 toxicity were 15.8%, 15.8%, 7.9%, respectively. there were no grade 4 toxicity and treatment-related death. Conclusion: Combination of three dimensional-conformal radiotherapy with capecitabine is active in advanced rectal cancer, It is a well-tolerated regimen. (authors)

  19. Comparison of intensity-modulated radiotherapy and 3-dimensional conformal radiotherapy as adjuvant therapy for gastric cancer.

    Science.gov (United States)

    Minn, A Yuriko; Hsu, Annie; La, Trang; Kunz, Pamela; Fisher, George A; Ford, James M; Norton, Jeffrey A; Visser, Brendan; Goodman, Karyn A; Koong, Albert C; Chang, Daniel T

    2010-08-15

    The current study was performed to compare the clinical outcomes and toxicity in patients treated with postoperative chemoradiotherapy for gastric cancer using intensity-modulated radiotherapy (IMRT) versus 3-dimensional conformal radiotherapy (3D CRT). Fifty-seven patients with gastric or gastroesophageal junction cancer were treated postoperatively: 26 with 3D CRT and 31 with IMRT. Concurrent chemotherapy was capecitabine (n=31), 5-fluorouracil (5-FU) (n=25), or none (n=1). The median radiation dose was 45 Gy. Dose volume histogram parameters for kidney and liver were compared between treatment groups. The 2-year overall survival rates for 3D CRT versus IMRT were 51% and 65%, respectively (P=.5). Four locoregional failures occurred each in the 3D CRT (15%) and the IMRT (13%) patients. Grade>or=2 acute gastrointestinal toxicity was found to be similar between the 3D CRT and IMRT patients (61.5% vs 61.2%, respectively) but more treatment breaks were needed (3 vs 0, respectively). The median serum creatinine from before radiotherapy to most recent creatinine was unchanged in the IMRT group (0.80 mg/dL) but increased in the 3D CRT group from 0.80 mg/dL to 1.0 mg/dL (P=.02). The median kidney mean dose was higher in the IMRT versus the 3D CRT group (13.9 Gy vs 11.1 Gy; P=.05). The median kidney V20 was lower for the IMRT versus the 3D CRT group (17.5% vs 22%; P=.17). The median liver mean dose for IMRT and 3D CRT was 13.6 Gy and 18.6 Gy, respectively (P=.19). The median liver V30 was 16.1% and 28%, respectively (PCancer Society.

  20. Therapeutic effect analysis of three dimensional conformal radiotherapy non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yao Zhijun; Cao Yongzhen; Zhang Wenxue; Liang Feng

    2012-01-01

    Objective: To analyse the treatment effect of non-small cell lung cancer of three dimensional conformal radiotherapy (3D-CRT) and to study the effect of patient survival related factors. Methods: Retrospective analysis was mack for 136 cases of non-small cell lung cancer, all accept 3D-CRT, through the case data collection and long-term follow-up, using the single factor and multiple factor analysis survival time and its influencing factors. Results: The recent curative effects of 136 cases of patients with three dimensional conformal radiotherapy: Complete response (CR) 14.7% (20/136), partial response (PR) 60.3 (82/136), stable disease(SD) 19.9% (27/136), progression disease (PD) 5.1% (7/136), total effective rate is 75% (102/136). One, two, three, five year survival rate is 79.4%, 45.4%, 22.1%, 12.5%. Side effects: Class 1 radiated esophagitis 35 cases, Class 2 radiated esophagitis 16 cases, Class 3 and above radiated esophagitis 0 case. Class I radiated pneumonia 20 cases, Class 2 radiated pneumonia 9 cases, Class 3 radiated pneumonia 0 case. Single factor analysis shows the influence of gender, age, pathology, phase, dose, and first-phase curative effect to the survival time are of a statistical significance, Multiple factor analysis showed KPS score, phase, dose, first-phase curative effect are the survival time independent factors. Conclusion: 3D-CRT for patients with non-small cell lung carcinoma is a safe, effective treatment method, Side effects are relatively low, and the patients survival time is long after radiotherapy. (authors)

  1. Radiological response and dosimetry in physical phantom of head and neck for 3D conformational radiotherapy

    International Nuclear Information System (INIS)

    Thompson, Larissa

    2013-01-01

    Phantoms are tools for simulation of organs and tissues of the human body in radiology and radiotherapy. This thesis describes the development, validation and, most importantly, the use of a physical head and neck phantom in radiology and radiotherapy, with the purpose of evaluating dose distribution using Gafchromic EBT2 film in 15 MV 3D conformal radiotherapy. The work was divided in two stages, (1) development of new equivalent tissues and improvement of the physical phantom, and (2) use of the physical phantom in experimental dosimetry studies. In phase (1) parameters such as mass density, chemical composition of tissues, anatomical and biometric measurements were considered, as well as aspects of imaging by computed tomography (CT) and radiological response representation in Hounsfield Units (HU), which were compared with human data. Radiological experiments of in-phantom simulated brain pathologies were also conducted. All those results matched human-sourced data, therefore the physical phantom is a suitable simulator that may be used to enhance radiological protocols and education in medical imaging. The main objective in phase (2) was to evaluate the spatial dose distribution in a brain tumor simulator inserted inside the head and neck phantom developed by the Ionizing Radiation Research Group (NRI), exposed to 15 MV 3D conformal radiotherapy, for internal dose assessment. Radiation planning was based on CT images of the physical phantom with a brain tumor simulator made with equivalent material. The treatment planning system (TPS), CAT3D software, used CT images and prescribed a dose of 200 cGy, distributed in three fields of radiation, in a T-shaped pattern. The TPS covered the planning treatment volume (PTV) with 97% of the prescribed dose. A solid water phantom and radiochromic Gafchromic EBT2 film were used for calibration procedures, generating a dose response curve as a function of optical density (OD). After calibration and irradiation, the film

  2. [Technique of complex mammary irradiation: Mono-isocentric 3D conformational radiotherapy and helical tomotherapy].

    Science.gov (United States)

    Vandendorpe, B; Guilbert, P; Champagne, C; Antoni, T; Nguyen, T D; Gaillot-Petit, N; Servagi Vernat, S

    2017-12-01

    To evaluate the dosimetric contribution of helical tomotherapy for breast cancers compared with conformal radiotherapy in mono-isocentric technique. For 23 patients, the dosimetric results in mono-isocentric 3D conformational radiotherapy did not satisfy the constraints either of target volumes nor organs at risk. A prospective dosimetric comparison between mono-isocentric 3D conformational radiotherapy and helical tomotherapy was therefore carried out. The use of helical tomotherapy showed a benefit in these 23 patients, with either an improvement in the conformity index or homogeneity, but with an increase in low doses. Of the 23 patients, two had pectus excavatum, five had past thoracic irradiation and two required bilateral irradiation. The other 14 patients had a combination of morphology and/or indication of lymph node irradiation. For these patients, helical tomotherapy was therefore preferred to mono-isocentric 3D conformational radiotherapy. Tomotherapy appears to provide better homogeneity and tumour coverage. This technique of irradiation may be justified in the case of morphological situations such as pectus exavatum and in complex clinical situations. In other cases, conformal radiotherapy in mono-isocentric technique remains to be favoured. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  3. 3D-Conformal Versus Intensity-Modulated Postoperative Radiotherapy of Vaginal Vault: A Dosimetric Comparison

    International Nuclear Information System (INIS)

    Cilla, Savino; Macchia, Gabriella; Digesu, Cinzia; Deodato, Francesco; Romanella, Michele; Ferrandina, Gabriella; Padula, Gilbert; Picardi, Vincenzo; Scambia, Giovanni; Piermattei, Angelo; Morganti, Alessio Giuseppe

    2010-01-01

    We evaluated a step-and-shoot IMRT plan in the postoperative irradiation of the vaginal vault compared with equispaced beam arrangements (3-5) 3D-radiotherapy (RT) optimized plans. Twelve patients were included in this analysis. Four plans for each patient were compared in terms of dose-volume histograms, homogeneity index (HI), and conformity index (CI): (1) 3 equispaced beam arrangement 3D-RT; (2) 4 equispaced beam arrangement 3D-RT; (3) 5 equispaced beam arrangement 3D-RT; (4) step-and-shoot IMRT technique. CI showed a good discrimination between the four plans. The mean scores of CI were 0.58 (range: 0.38-0.67) for the 3F-CRT plan, 0.58 (range: 0.41-0.66) for 4F-CRT, 0.62 (range: 0.43-0.68) for 5F-CRT and 0.69 (range: 0.58-0.78) for the IMRT plan. A significant improvement of the conformity was reached by the IMRT plan (p mean , V90%, V95%, V100% was recorded for rectal and bladder irradiation with the IMRT plan. Surprisingly, IMRT supplied a significant dose reduction also for rectum and bladder V30% and V50%. A significant dosimetric advantage of IMRT over 3D-RT in the adjuvant treatment of vaginal vault alone in terms of treatment conformity and rectum and bladder sparing is shown.

  4. 94: Treatment plan optimization for conformal therapy

    International Nuclear Information System (INIS)

    Rosen, I.I.; Lane, R.G.

    1987-01-01

    Computer-controlled conformal radiation therapy techniques can deliver complex treatments utilizing large numbers of beams, gantry angles and beam shapes. Linear programming is well-suited for planning conformal treatments. Given a list of available treatment beams, linear programming calculates the relative weights of the beams such that the objective function is optimized and doses to constraint points are within the prescribed limits. 5 refs.; 3 figs

  5. Visual Outcome and Tumor Control After Conformal Radiotherapy for Patients With Optic Nerve Sheath Meningioma

    International Nuclear Information System (INIS)

    Arvold, Nils D.; Lessell, Simmons; Bussiere, Marc; Beaudette, Kevin; Rizzo, Joseph F.; Loeffler, Jay S.; Shih, Helen A.

    2009-01-01

    Purpose: Optic nerve sheath meningioma (ONSM) is a rare tumor that almost uniformly leads to visual dysfunction and even blindness without intervention. Because surgical extirpation carries a high risk of postoperative blindness, vision-sparing treatment strategies are desirable. Methods and Materials: We retrospectively reviewed the outcomes of 25 patients (25 optic nerves) with ONSM, treated at a single institution with conformal fractionated radiotherapy by either stereotactic photon or proton radiation. Primary endpoints were local control and visual acuity. Results: The patients presented with symptoms of visual loss (21) or orbital pain (3) or were incidentally diagnosed by imaging (3). The mean age was 44 years, and 64% were female patients. The indication for treatment was the development or progression of symptoms. Of the patients, 13 were treated with photons, 9 were treated with protons, and 3 received a combination of photons and protons. The median dose delivered was 50.4 gray equivalents (range, 45-59.4 gray equivalents). Median follow-up after radiotherapy was 30 months (range, 3-168 months), with 3 patients lost to follow-up. At most recent follow-up, 21 of 22 patients (95%) had improved (14) or stable (7) visual acuity. One patient had worsened visual acuity after initial postirradiation improvement. Of the 22 patients, 20 (95%) had no radiographic progression. Three patients had evidence of asymptomatic, limited retinopathy on ophthalmologic examination, and one had recurrent ONSM 11 years after treatment. Conclusions: Highly conformal, fractionated radiation therapy for symptomatic primary ONSM provides tumor control and improvement in visual function in most cases, with minimal treatment-induced morbidity. Longer follow-up is needed to assess the durability of tumor control and treatment-related late effects.

  6. Development of dose audits for complex treatment techniques in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Stefanic, A. M.; Molina, L.; Vallejos, M.; Montano, G.; Zaretzky, A.; Saravi, M., E-mail: stefanic@cae.cnea.gov.ar [Centro Regional de Referencia con Patrones Secundarios para Dosimetria - CNEA, Presbitero Juan Gonzalez y Aragon 15, B1802AYA Ezeiza (Argentina)

    2014-08-15

    This work was performed in the frame of a Coordinated Research Project (CRP) with IAEA whose objective was to extend the scope of activities carried out by national TLD-based networks from dosimetry audit for rectangular radiation fields to irregular and small fields relevant to modern radiotherapy. External audit is a crucial element in QA programmes for clinical dosimetry in radiotherapy, therefore a methodology and procedures were developed and were made available for dose measurement of complex radiotherapy parameters used for cancer treatment. There were three audit steps involved in this CRP: TLD based dosimetry for irregular MLC fields for conformal radiotherapy, dosimetry in the presence of heterogeneities and 2D MLC shaped fields relevant to stereotactic radiotherapy and applicable to dosimetry for IMRT. In addition, a new development of film-based 2D dosimetry for testing dose distributions in small field geometry was included. The plan for each audit step involved a pilot study and a trial audit run with a few local hospitals. The pilot study focused on conducting and evaluation of the audit procedures with all participants. The trial audit run was the running of the audit procedures by the participants to test them with a few local radiotherapy hospitals. This work intends to provide audits which are much nearer clinical practice than previous audits as they involve significant testing of Tps methods, as well as verifications to determinate whether hospitals can correctly calculate dose delivery in radiation treatments. (author)

  7. Development of dose audits for complex treatment techniques in radiotherapy

    International Nuclear Information System (INIS)

    Stefanic, A. M.; Molina, L.; Vallejos, M.; Montano, G.; Zaretzky, A.; Saravi, M.

    2014-08-01

    This work was performed in the frame of a Coordinated Research Project (CRP) with IAEA whose objective was to extend the scope of activities carried out by national TLD-based networks from dosimetry audit for rectangular radiation fields to irregular and small fields relevant to modern radiotherapy. External audit is a crucial element in QA programmes for clinical dosimetry in radiotherapy, therefore a methodology and procedures were developed and were made available for dose measurement of complex radiotherapy parameters used for cancer treatment. There were three audit steps involved in this CRP: TLD based dosimetry for irregular MLC fields for conformal radiotherapy, dosimetry in the presence of heterogeneities and 2D MLC shaped fields relevant to stereotactic radiotherapy and applicable to dosimetry for IMRT. In addition, a new development of film-based 2D dosimetry for testing dose distributions in small field geometry was included. The plan for each audit step involved a pilot study and a trial audit run with a few local hospitals. The pilot study focused on conducting and evaluation of the audit procedures with all participants. The trial audit run was the running of the audit procedures by the participants to test them with a few local radiotherapy hospitals. This work intends to provide audits which are much nearer clinical practice than previous audits as they involve significant testing of Tps methods, as well as verifications to determinate whether hospitals can correctly calculate dose delivery in radiation treatments. (author)

  8. Prospective randomized trail on chrono-chemotherapy + late course three dimensional conformal radio-therapy and conventional chemotherapy plus radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Jin Feng; Ouyang Jinling; Dong Hongmin; Wu Weili; Chen Haixia; He Zhihui

    2005-01-01

    neck, as cure while 50 Gy/5w for prophylaxis. Results: The CR and PR of the CCR group was 45.5% and 95.5%, while the CR and PR of RCR group was 23.8% and 71.4% respectively. There was significant difference between the two groups in CR and PR (P<0.05). Higher incidence of stomatitis, nausea, vomiting, diarrhea, and bone marrow suppression was found in the RCR group than in the CCR group (P<0.05). Conclusion: Late-course three dimensional conformal radiotherapy plus chrono- chemotherapy (DDP + 5-FU/CF) is more favorable in the treatment of NPC with milder toxicity and side effects. Long term results will have to wait for further study.(authors)

  9. Patterns of failure in children with medulloblastoma treated with 3D conformal radiotherapy

    International Nuclear Information System (INIS)

    Skowronska-Gardas, Anna; Chojnacka, Marzanna; Morawska-Kaczynska, Marzena; Perek, Danuta; Perek-Polnik, Marta

    2007-01-01

    Background and purpose: Craniospinal irradiation for medulloblastoma is one of the most complex techniques employed in radiotherapy. Many reports stress the impact of irradiation quality on survival in these patients. Our report presents the outcome and patterns of failure for 95 patients treated with 3D conformal radiotherapy (3D-CRT). Materials and methods: From 1998 to 2003, 95 children with medulloblastoma received 3D conformal radiotherapy. All of them were previously treated with surgery and chemotherapy. The brain and upper spinal cord were treated with two lateral 6 MV photon fields. In four patients, the cribriform plate was irradiated by the additional field. For primary tumour bed we applied two or three photon beams. Spinal cord was irradiated either with 18-20 MeV electron fields or with a mixed beam. Results: With a median follow-up of 48 months, 32/95 patients suffered a multifocal (21) or isolated (11) recurrence. We evaluated every primary site of failure. In all patients, the recurrence appeared within the isodose level of 95-100%. Conclusions: Patterns of failure in medulloblastoma patients treated with 3D conformal radiotherapy indicated that the relapse was mainly associated with poor response to pre-irradiation chemotherapy. We believe that 3D conformal radiotherapy allows avoiding failures, related to radiotherapy uncertainties

  10. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique.

    Science.gov (United States)

    Brodin, N Patrik; Munck af Rosenschöld, Per; Blomstrand, Malin; Kiil-Berthlesen, Anne; Hollensen, Christian; Vogelius, Ivan R; Lannering, Birgitta; Bentzen, Søren M; Björk-Eriksson, Thomas

    2014-04-01

    We investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy. We included 17 pediatric medulloblastoma patients to represent the variability in tumor location relative to the hippocampal region. Treatment plans were generated using 3D conformal radiotherapy, hippocampal sparing intensity-modulated radiotherapy, and spot-scanned proton therapy, using 3 different treatment margins for the conformal tumor boost. Neurocognitive impairment risk was estimated based on dose-response models from pediatric CNS malignancy survivors and compared among different margins and treatment techniques. Mean hippocampal dose and corresponding risk of cognitive impairment were decreased with decreasing treatment margins (P < .05). The largest risk reduction, however, was seen when applying hippocampal sparing proton therapy-the estimated risk of impaired task efficiency (95% confidence interval) was 92% (66%-98%), 81% (51%-95%), and 50% (30%-70%) for 3D conformal radiotherapy, intensity-modulated radiotherapy, and proton therapy, respectively, for the smallest boost margin and 98% (78%-100%), 90% (60%-98%), and 70% (39%-90%) if boosting the whole posterior fossa. Also, the distance between the closest point of the planning target volume and the center of the hippocampus can be used to predict mean hippocampal dose for a given treatment technique. We estimate a considerable clinical benefit of hippocampal sparing radiotherapy. In choosing treatment margins, the tradeoff between margin size and risk of neurocognitive impairment quantified here should be considered.

  11. Auto-optimisation for three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Wu, V.W.C.; Kwong, D.W.L.; Sham, J.S.T.; Mui, A.W.L.

    2003-01-01

    Purpose: The purpose of this study was to evaluate the application of auto-optimisation in the treatment planning of three-dimensional conformal radiotherapy (3DCRT) of nasopharyngeal carcinoma (NPC). Methods: Twenty-nine NPC patients were planned by both forward planning and auto-optimisation methods. The forward plans, which consisted of three coplanar facial fields, were produced according to the routine planning criteria. The auto-optimised plans, which consisted of 5-15 (median 9) fields, were generated by the planning system after prescribing the dose requirements and the importance weightings of the planning target volume and organs at risk. Plans produced by the two planning methods were compared by the dose volume histogram, tumour control probability (TCP), conformity index and normal tissue complication probability (NTCP). Results: The auto-optimised plans reduced the average planner's time by over 35 min. It demonstrated better TCP and conformity index than the forward plans (P=0.03 and 0.04, respectively). Besides, the parotid gland and temporo-mandibular (TM) joint were better spared with the mean dose reduction of 31.8 and 17.7%, respectively. The slight trade off was the mild dose increase in spinal cord and brain stem with their maximum doses remaining within the tolerance limits. Conclusions: The findings demonstrated the potentials of auto-optimisation for improving target dose and parotid sparing in the 3DCRT of NPC with saving of the planner's time

  12. Auto-optimisation for three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Wu, V.W.C. E-mail: orvinwu@polyu.edu.hk; Kwong, D.W.L.; Sham, J.S.T.; Mui, A.W.L

    2003-08-01

    Purpose: The purpose of this study was to evaluate the application of auto-optimisation in the treatment planning of three-dimensional conformal radiotherapy (3DCRT) of nasopharyngeal carcinoma (NPC). Methods: Twenty-nine NPC patients were planned by both forward planning and auto-optimisation methods. The forward plans, which consisted of three coplanar facial fields, were produced according to the routine planning criteria. The auto-optimised plans, which consisted of 5-15 (median 9) fields, were generated by the planning system after prescribing the dose requirements and the importance weightings of the planning target volume and organs at risk. Plans produced by the two planning methods were compared by the dose volume histogram, tumour control probability (TCP), conformity index and normal tissue complication probability (NTCP). Results: The auto-optimised plans reduced the average planner's time by over 35 min. It demonstrated better TCP and conformity index than the forward plans (P=0.03 and 0.04, respectively). Besides, the parotid gland and temporo-mandibular (TM) joint were better spared with the mean dose reduction of 31.8 and 17.7%, respectively. The slight trade off was the mild dose increase in spinal cord and brain stem with their maximum doses remaining within the tolerance limits. Conclusions: The findings demonstrated the potentials of auto-optimisation for improving target dose and parotid sparing in the 3DCRT of NPC with saving of the planner's time.

  13. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique

    DEFF Research Database (Denmark)

    Brodin, N. Patrik; af Rosenschold, Per Munck; Blomstrand, Malin

    2014-01-01

    BackgroundWe investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy.MethodsWe included 17 pediatric medulloblastoma...

  14. Application of biological dose concept in dose optimization for conformal radiotherapy of prostate carcinoma

    International Nuclear Information System (INIS)

    Li Yunhai; Liao Yuan; Zhou Lijun; Pan Ziqiang; Feng Yan

    2003-01-01

    Objective: On basis of physical dose optimization, LQ model was used to investigate the difference between the curves of biological effective dose and physical isodose. The influence of applying the biological dose concept on three dimensional conformal radiotherapy of prostate carcinoma was discussed. Methods: Four treatment plannings were designed for physical dose optimization: three fields, four-box fields, five fields and six fields. Target dose uniformity and protection of the critical tissue-rectum were used as the principal standard for designing the treatment planning. Biological effective dose (BED) was calculated by LQ model. The difference between the BED curve drawn in the central layer and the physical isodose curve was studied. The difference between the adjusted physical dose (APD) and the physical dose was also studied. Results: Five field planning was the best in target dose uniformity and protection of the critical tissue-rectum. The physical dose was uniform in the target, but the biological effective doses revealed great discrepancy in the biological model. Adjusted physical dose distribution also displayed larger discrepancy than the physical dose unadjusted. Conclusions: Intensified Modulated Radiotherapy (IMRT) technique with inversion planning using biological dose concept may be much more advantageous to reach a high tumor control probability and low normal tissue complication probability

  15. A survey on the state on the use of conformation radiotherapy units in Japan

    International Nuclear Information System (INIS)

    Tomaru, Teizo; Onai, Yoshio; Abe, Shunsuke

    1985-01-01

    A survey on the stage on the use of conformation radiotherapy units in Japan was performed by the Radiotherapy Equipments Committee of the Japanese Association for Radiotherapy Systems. The questionnaire was sent to 34 hospitals, which are all the hospitals equipped with these units, and 13 cancer and adult disease centers. The answers were collected from 42 hospitals, of which the 31 from formers and 11 from latters. In June, 1984, 27 conformation radiotherapy units (11 units with a pair of lower jaws and 16 units with multi-leaf collimators) were being used at 26 hospitals answered to questionnaire. During a month from May 16 to June 15 in 1984, conformation radiotherapy was performed at 10 hopsitals, and mean number of patients per day treated with these irradiation techniques was 3.7 +- 3.5. Fixed beam radiotherapy with irregular shape fields using multi-leaf collimators was also performed at 8 hospitals and mean number of patients per day treated with this fixed beam was 6.6 +- 3.9. Hollow-out irradiation technique was used at 4 hospitals, and 3.8 patients per day per hospital were treated with this technique. (author)

  16. Neoadjuvant androgen deprivation and prostate gland shrinkage during conformal radiotherapy

    International Nuclear Information System (INIS)

    Sanguineti, Giuseppe; Marcenaro, Michela; Franzone, Paola; Foppiano, Franca; Vitale, Vito

    2003-01-01

    Purpose: The shrinking effect of 3-month neoadjuvant androgen deprivation (NAD) on preradiotherapy prostate gland volume is well documented. However, recently, it has been shown that the cancerous prostate gland keeps shrinking up to 12 months after NAD start. Thus, if such a reduction is not taken into account, a larger than planned portion of the surrounding normal tissues might shift in the high-dose region during conformal radiotherapy (3DCRT) course. The present study was undertaken to quantify this issue. Materials and Methods: Prostate gland volume reduction between planning CT (plCT) and the last week of 3DCRT (tmtCT) was prospectively assessed in 33 consecutive patients with localized prostate carcinoma. The median time interval between plCT and tmtCT was 2.5 months (2.1-2.7 months). A single observer was asked to draw on each slice prostate gland volume as appropriate. The observer was 'blind' to the timing of CT (plCT vs. tmtCT). In order to estimate intra-observer variability, prostate gland delineation was repeated twice for each data set. Mean prostate gland change, plCT and tmtCT cumulative dose volume histogram (DVH) calculations for the rectum were analyzed for each patient. Results were correlated to AD status and its duration before plCT. Means were compared by non-parametric rank tests. Results: Based on an internal protocol, 14 patients (42%) did not receive AD, while 19 patients (58%) had undergone neoadjuvant and concomitant AD. The median duration of AD before plCT ranged from 0.2 to 6 months (median: 2.9 months). Although individual data were highly variable, compared to plCT volume, mean prostate gland volume change at the end of 3DCRT was similar for patients receiving (-7.3%) or not (-7%) androgen deprivation (P=0.77). However, within the group of patients treated with hormones, patients starting AD within 3 months from plCT had a significantly larger reduction in prostate volume (-14.2%) than patients with longer NAD duration (-1.1%, P

  17. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P. [IRCC, Candiolo (Italy)

    2011-10-15

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was < 10 mm in 33 patients (53%) and > 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long

  18. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P.

    2011-01-01

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long-term results are needed to assess

  19. Esophageal perforation during or after conformal radiotherapy for esophageal carcinoma

    International Nuclear Information System (INIS)

    Chen Haiyan; Ma Xiumei; Ye Ming; Hou Yanli; Xie Huaying; Bai Yongrui

    2014-01-01

    The aim of this study was to analyze the risk factors and prognosis for patients with esophageal perforation occurring during or after radiotherapy for esophageal carcinoma. We retrospectively analyzed 322 patients with esophageal carcinoma. These patients received radiotherapy for unresectable esophageal tumors, residual tumors after operation, or local recurrence. Of these, 12 had radiotherapy to the esophagus before being admitted, 68 patients had concurrent chemoradiotherapy (CRT), and 18 patients had esophageal perforation after RT (5.8%). Covered self-expandable metallic stents were placed in 11 patients. Two patients continued RT after stenting and control of infection; one of these suffered a new perforation, and the other had a massive hemorrhage. The median overall survival was 2 months (0-3 months) compared with 17 months in the non-perforation group. In univariate analysis, the Karnofsky performance status (KPS) being ≤ 70, age younger than 60, T4 stage, a second course of radiotherapy to the esophagus, extracapsular lymph nodes (LN) involving the esophagus, a total dose > 100 Gy (biologically effective dose -10 ), and CRT were risk factors for perforation. In multivariate analysis, age younger than 60, extracapsular LN involving the esophagus, T4 stage, and a second course of radiotherapy to the esophagus were risk factors. In conclusion, patients with T4 stage, extracapsular LN involving the esophagus, and those receiving a second course of RT should be given particular care to avoid perforation. The prognosis after perforation was poor. (author)

  20. A custom made phantom for dosimetric audit and quality assurance of three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Radaideh, K.M.; Matalqah, L.M.; Matalqah, L.M.; Tajuddin, A.A.; Luen, F.W.L.; Bauk, S.; Abdel Munem, E.M.E.

    2012-01-01

    The ultimate check of the actual dose delivered to a patient in radiotherapy can be achieved by using dosimetric measurements. The aims of this study were to develop and evaluate a custom handmade head and neck phantom for evaluation of Three-Dimensional Conformal Radiation Therapy (3D-CRT) dose planning and delivery. A phantom of head and neck region of a medium built male patient with nasopharyngeal cancer was constructed from Perspex material. Primary and secondary Planning Target Volume (PTV) and twelve Organs at Risk (OAR) were delineated using Treatment Planning System (TPS) guided by computed tomography printout transverse images. One hundred and seven (107) holes distributed among the organs were loaded with Rod-shaped Thermoluminescent dosimeters (LiF:Mg, Ti TLDs) after common and individual calibration. Head and neck phantom was imaged, planned and irradiated conformally (3D-CRT) by linear accelerator (LINAC Siemens Artiste). The planned predicted doses by TPS at PTV and OAR regions were obtained and compared with the TLD measured doses using the phantom. Repeated TLD measurements were reproducible with a percent standard deviation of < 3.5 %. Moreover, the average of dose discrepancies between TLDs reading and TPS predicted doses were found to be < 5.3 %. The phantom's preliminary results have proved to be a valuable tool for 3D-CRT treatment dose verification. (author)

  1. Cranial radiotherapy guided by computed tomography with or without fields conformation in pediatric

    International Nuclear Information System (INIS)

    Fernandez, Diego; Caussa, Lucas; Murina, Patricia; Zunino, Silvia

    2007-01-01

    Many malignancies in children can be cured by radiotherapy, acute toxicity and the significant effect of delayed treatment are worrying for the patient, family and society. Therefore, the end of the pediatric radiotherapy is to maintain or improve the cure rate of cancer, diminishing the aftermath of treatment. The goal of this study is to measure differences in doses to the healthy tissue of the central nervous system with two radiotherapy techniques, both guided by computed tomography [es

  2. Changes in Pulmonary Function After Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, or Proton Beam Therapy for Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Lopez Guerra, Jose L.; Gomez, Daniel R.; Zhuang Yan; Levy, Lawrence B.; Eapen, George; Liu, Hongmei; Mohan, Radhe; Komaki, Ritsuko; Cox, James D.; Liao Zhongxing

    2012-01-01

    Purpose: To investigate the extent of change in pulmonary function over time after definitive radiotherapy for non-small-cell lung cancer (NSCLC) with modern techniques and to identify predictors of changes in pulmonary function according to patient, tumor, and treatment characteristics. Patients and Methods: We analyzed 250 patients who had received ≥60 Gy radio(chemo)therapy for primary NSCLC in 1998–2010 and had undergone pulmonary function tests before and within 1 year after treatment. Ninety-three patients were treated with three-dimensional conformal radiotherapy, 97 with intensity-modulated radiotherapy, and 60 with proton beam therapy. Postradiation pulmonary function test values were evaluated among individual patients compared with the same patient’s preradiation value at the following time intervals: 0–4 (T1), 5–8 (T2), and 9–12 (T3) months. Results: Lung diffusing capacity for carbon monoxide (DLCO) was reduced in the majority of patients along the three time periods after radiation, whereas the forced expiratory volume in 1 s per unit of vital capacity (FEV1/VC) showed an increase and decrease after radiation in a similar percentage of patients. There were baseline differences (stage, radiotherapy dose, concurrent chemotherapy) among the radiation technology groups. On multivariate analysis, the following features were associated with larger posttreatment declines in DLCO: pretreatment DLCO, gross tumor volume, lung and heart dosimetric data, and total radiation dose. Only pretreatment DLCO was associated with larger posttreatment declines in FEV1/VC. Conclusions: Lung diffusing capacity for carbon monoxide is reduced in the majority of patients after radiotherapy with modern techniques. Multiple factors, including gross tumor volume, preradiation lung function, and dosimetric parameters, are associated with the DLCO decline. Prospective studies are needed to better understand whether new radiation technology, such as proton beam therapy

  3. Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer

    International Nuclear Information System (INIS)

    Kim, Dae Woong; Kim, Jong Won; Choi, Yun Kyeong; Kim, Jung Soo; Hwang, Jae Woong; Jeong, Kyeong Sik; Choi, Gye Suk

    2008-01-01

    The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. In this paper, we comparing the dose distribution between three dimensional conformal radiation radiotherapy (3D-CRT) and helical tomotherapy (TOMO) plan for partial breast cancer. Twenty patients were included in the study, and plans for two techniques were developed for each patient (left breast:10 patients, right breast:10 patients). For each patient 3D-CRT planning was using pinnacle planning system, inverse plan was made using Tomotherapy Hi-Art system and using the same targets and optimization goals. We comparing the Homogeneity index (HI), Conformity index (CI) and sparing of the organs at risk for dose-volume histogram. Whereas the HI, CI of TOMO was significantly better than the other, 3D-CRT was observed to have significantly poorer HI, CI. The percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose was 3D-CRT (mean: 40.4%), TOMO (mean: 18.3%). The average ipsilateral lung volume percentage receiving 20% of the PD was 3D-CRT (mean: 4.8%), TOMO (mean: 14.2), concerning the average heart volume receiving 20% and 10% of the PD during treatment of left breast cancer 3D-CRT (mean: 1.6%, 3.0%), TOMO (mean: 9.7%, 26.3%) In summary, 3D-CRT and TOMO techniques were found to have acceptable PTV coverage in our study. However, in TOMO, high conformity to the PTV and effective breast tissue sparing was achieved at the expense of considerable dose exposure to the lung and heart.

  4. Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: Does IMRT increase the integral dose to normal brain?

    International Nuclear Information System (INIS)

    Hermanto, Ulrich; Frija, Erik K.; Lii, MingFwu J.; Chang, Eric L.; Mahajan, Anita; Woo, Shiao Y.

    2007-01-01

    Purpose: To determine whether intensity-modulated radiotherapy (IMRT) treatment increases the total integral dose of nontarget tissue relative to the conventional three-dimensional conformal radiotherapy (3D-CRT) technique for high-grade gliomas. Methods and Materials: Twenty patients treated with 3D-CRT for glioblastoma multiforme were selected for a comparative dosimetric evaluation with IMRT. Original target volumes, organs at risk (OAR), and dose-volume constraints were used for replanning with IMRT. Predicted isodose distributions, cumulative dose-volume histograms of target volumes and OAR, normal tissue integral dose, target coverage, dose conformity, and normal tissue sparing with 3D-CRT and IMRT planning were compared. Statistical analyses were performed to determine differences. Results: In all 20 patients, IMRT maintained equivalent target coverage, improved target conformity (conformity index [CI] 95% 1.52 vs. 1.38, p mean by 19.8% and D max by 10.7%), optic chiasm (D mean by 25.3% and D max by 22.6%), right optic nerve (D mean by 37.3% and D max by 28.5%), and left optic nerve (D mean by 40.6% and D max by 36.7%), p ≤ 0.01. This was achieved without increasing the total nontarget integral dose by greater than 0.5%. Overall, total integral dose was reduced by 7-10% with IMRT, p < 0.001, without significantly increasing the 0.5-5 Gy low-dose volume. Conclusions: These results indicate that IMRT treatment for high-grade gliomas allows for improved target conformity, better critical tissue sparing, and importantly does so without increasing integral dose and the volume of normal tissue exposed to low doses of radiation

  5. Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

    International Nuclear Information System (INIS)

    Capelle, Lisa; Warkentin, Heather; MacKenzie, Marc; Joseph, Kurian; Gabos, Zsolt; Pervez, Nadeem; Tankel, Keith; Chafe, Susan; Amanie, John; Ghosh, Sunita; Parliament, Matthew; Abdulkarim, Bassam

    2012-01-01

    Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P V50 (1.4% vs 5.9%, respectively; P=.001) but higher skin V40 and skin V30 (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients receiving adjuvant breast RT.

  6. Effect of Concurrent High-Dose Cisplatin Chemotherapy and Conformal Radiotherapy on Cervical Esophageal Cancer Survival

    International Nuclear Information System (INIS)

    Huang Shaohui; Lockwood, Gina; Brierley, James; Cummings, Bernard; Kim, John; Wong, Rebecca; Bayley, Andrew; Ringash, Jolie

    2008-01-01

    Purpose: To determine whether a change in treatment policy to conformal, elective nodal radiotherapy and concurrent high-dose cisplatin improved survival for cervical esophageal cancer patients. Methods and Materials: All cervical esophageal cancer patients treated between 1997 and 2005 were restaged (1983 American Joint Committee on Cancer criteria). Patients treated before 2001 (previous cohort [PC]) were compared with those treated from 2001 onward (recent cohort [RC]). The PC institutional chemoradiotherapy protocol was 54 Gy in 20 fractions within 4 weeks, with 5-fluorouracil (1,000 mg/m 2 ) on Days 1-4 and either mitomycin C (10 mg/m 2 ) or cisplatin (75 mg/m 2 ) on Day 1. The RC institutional chemoradiotherapy protocol was conformal radiotherapy, 70 Gy in 35 fractions within 7 weeks, to the primary tumor and elective nodes, with high-dose cisplatin (100 mg/m 2 ) on Days 1, 22, and 43. Results: The median follow-up was 3.1 years (PC, 8.1 and RC, 2.3). Of 71 patients (25 women and 46 men), 21 of 29 in the PC and 29 of 42 in the RC were treated curatively (curative subgroup, n = 50). Between the two groups, no differences in overall survival or locoregional relapse-free survival were seen. The overall survival rate at 2 and 5 years was 35% (range, 24-47%) and 21% (range, 12-32%) in the whole group and 46% (range 32-60%) and 28% (range, 15-42%) in the curative group, respectively. In the curative group, no statistically significant prognostic factors were found. Trends toward better locoregional relapse-free survival were seen in women (2-year rate, 73% vs. for men, 36%; p = 0.08) and in patients aged >64 years (2-year rate, 68% vs. age ≤64 years, 34%; p = 0.10). Conclusion: No survival improvement could be demonstrated after changing the treatment policy to high-dose cisplatin-based, conventionally fractionated conformal chemoradiotherapy. Female gender and older age might predict for better outcomes

  7. Hyperfractionated 3D conformal radiotherapy and concurrent chemotherapy for unresectable stage III non-small cell lung cancer

    International Nuclear Information System (INIS)

    Choi, E.K.; Ahn, S.D.; Yi, B.Y.; Chang, H.S.; Lee, J.H.; Suh, C.W.; Lee, J.S.; Kim, S.H.; Koh, Y.S.; Kim, W.S.; Kim, D.S.; Kim, W.D.; Sohn, K.H.

    1997-01-01

    Purpose/Objective: This phase II study has been conducted to determine the feasibility, toxicity, response rate, local control, distant metastasis, and survival of hyperfractionated 3D conformal radiotherapy and concurrent chemotherapy with mitomycin C, vinblastine, and cisplatin in unresectable stage III non-small cell lung cancer (NSCLC), and also to find the most ideal 3D conformal radiotherapy technique. Materials and Methods: From Aug 1993, 173 patients with unresectable stage III NSCLC were entered into this trial and 146 (84%) completed the treatment. Hyperfractionated radiotherapy was given to a total dose of 65-70 Gy (120 cGy/fx, bid) with concurrent 2 cycles of MVP chemotherapy (Mitomycin C 6 mg/m 2 d2 and d29, Vinblastine 6 mg/m 2 d2 and d29, Cisplatin 60 mg/m 2 d1 and d28). Of these 146 patients who completed the treatment, 78 received noncoplanar 3D conformal radiotherapy using 4-6 fields and 17 received coplanar segmented conformal radiotherapy. Clinical tumor response was assessed one month after the completion of radiotherapy by computerized tomography (CT) scan. Toxicity was graded by RTOG and SWOG criteria. Normal tissue complication probability (NTCP) for lung was calculated to find the correlation with radiation pneumonitis. Results: Nineteen (13%) had stage IIIa and 127 (87%) had IIIb disease including 16 with pleural effusion and 20 with supraclavicular lymph node metastases. Response rate was 74%, including 20% complete response and 54% partial response. With a minimum follow up of 12 months, overall survival was 60% at 1 year, 30% at 2 years and median survival was 15 months. Patients achieving a complete response (n=29) had a 2-year overall survival of 46.5% compared to 28.7% for partial responders (n=79) (p=.001). Actuarial local control was 66.7% at 1 year and 43.7% at 2 years. Actuarial distant free survival was 52.3% at 1 year and 39.8% at 2 years. Major hematologic toxicity (Gr 3-4) occurred in 33% of the patients but treatment delay

  8. Implementation of intensity-modulated conformational radiotherapy (IMRT) for the treatment of cervical cancers at the Alexis-Vautrin Centre; Implementation de la radiotherapie conformationnelle avec modulation d'intensite (RCMI) pour le traitement des cancers du col uterin au centre Alexis-Vautrin

    Energy Technology Data Exchange (ETDEWEB)

    Renard-Oldrini, S.; Brunaud, C.; Marchesi, V.; Tournier-Rangeard, L.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Nancy (France)

    2010-10-15

    The authors discuss the comparison of the treatment plans of eleven patients treated either by conformational irradiation for seven of them, or by intensity-modulated conformational irradiation (IMRT) for four of them. The IMRT results in a good target volume coverage, can better protect the intestine than the conventional irradiation, and therefore is very promising, notably in terms of digestive toxicity. Short communication

  9. Hormone levels in radiotherapy treatment related fatigue

    International Nuclear Information System (INIS)

    Biswal, B.M.; Mallik, G.S.

    2003-01-01

    Radiotherapy is known to cause debilitating treatment related fatigue. Fatigue in general is a conglomeration of psychological, physical, hematological and unknown factors influencing the internal milieu of the cancer patient. Radiotherapy can add stress at the cellular and somatic level to aggravate further fatigue in cancer patients undergoing radiotherapy. Stress related hormones might be mediating in the development of fatigue. This is an ongoing prospective study to evaluate if the hormonal profile related to stress is influenced by radiotherapy treatment related fatigue. The study was conducted from September 2002 onwards in the division of Radiotherapy and Oncology of our Medical School. Previously untreated patients with histopathology proof of malignancy requiring external beam radiotherapy were considered for this study. Selection criteria were applied to exclude other causes of fatigue. Initial fatigue score was obtained using Pipers Fatigue Score questionnaire containing 23 questions, subsequently final fatigue score was obtained at the end of radiotherapy. Blood samples were obtained to estimate the levels of ACTH, TSH, HGH, and cortisol on the final assessment. The hormone levels were compared with resultant post radiotherapy fatigue score. At the time of reporting 50 patients were evaluable for the study. The total significant fatigue score was observed among 12 (24%) patients. The individual debilitating fatigue score were behavioral severity 14 (28%), affective meaning 14(28%), Sensory 13 (26%) and cognitive mood 10 (20%) respectively. From the analysis of hormonal profile, growth hormone level > 1 ng/mL and TSH <0.03 appears to be associated with high fatigue score (though statistically not significant); whereas there was no correlation with ACTH and serum cortisol level. In our prospective study severe radiotherapy treatment related fatigue was found among our patient population. Low levels of TSH and high levels of GH appear to be associated

  10. Parotid gland-sparing 3-dimensional conformal radiotherapy results in less severe dry mouth in nasopharyngeal cancer patients: A dosimetric and clinical comparison with conventional radiotherapy

    International Nuclear Information System (INIS)

    Jen, Y.-M.; Shih Rompin; Lin, Y.-S.; Su, W.-F.; Ku, C.-H.; Chang, C.-S.; Shueng, P.-W.; Hwang, J.-M.; Liu, D.-W.; Chao, H.-L.; Lin, H.-Y.; Chang, L.-P.; Shum, W.-Y.; Lin, C.-S.

    2005-01-01

    Background and purpose: This study examined the efficacy of parotid gland sparing of three-dimensional conformal radiotherapy (3DCRT) compared with conventional radiotherapy for NPC patients. Both the dose given to the parotids and clinical assessment of dry mouth were conducted. Materials and methods: Dry mouth was assessed for 108 patients treated with conventional technique and 72 treated with 3DCRT. Dose analysis was performed in 48 patients of the 3DCRT group. A dose of 70 Gy was given to the midplane in conventional radiotherapy and to 90% isodose volume in 3DCRT. Prognostic factors affecting the severity of dry mouth were analyzed using Generalized Estimating Equation (GEE). Results: In the 3DCRT group about 50% of the patients' parotid glands received less than 25 Gy. Parallel analysis of dry mouth shows a significant decrease in the incidence of severe xerostomia after 3DCRT. The proportion of patients without dry mouth was also significantly higher in the 3DCRT group than the conventional group at 1-3 years after completion of radiotherapy. Although 3DCRT delivered a higher dose to the tumor, it spared the parotid gland significantly better than the conventional treatment. Late toxicities were mostly similar between the 2 groups while local control in T4 patients and survival were improved for 3DCRT. Conclusion: Dosimetrically and clinically 3DCRT is better than conventional technique regarding parotid gland protection

  11. Comparison of Heart and Coronary Artery Doses Associated With Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiotherapy for Distal Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kole, Thomas P.; Aghayere, Osarhieme; Kwah, Jason [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Yorke, Ellen D. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Goodman, Karyn A., E-mail: goodmank@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-08-01

    Purpose: To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Methods and Materials: Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Results: Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Conclusions: Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D

  12. Animation and radiobiological analysis of 3D motion in conformal radiotherapy.

    Science.gov (United States)

    MacKay, R I; Graham, P A; Moore, C J; Logue, J P; Sharrock, P J

    1999-07-01

    To allow treatment plans to be evaluated against the range of expected organ motion and set up error anticipated during treatment. Planning tools have been developed to allow concurrent animation and radiobiological analysis of three dimensional (3D) target and organ motion in conformal radiotherapy. Surfaces fitted to structures outlined on CT studies are projected onto pre-treatment images or onto megavoltage images collected during the patient treatment. Visual simulation of tumour and normal tissue movement is then performed by the application of three dimensional affine transformations, to the selected surface. Concurrent registration of the surface motion with the 3D dose distribution allows calculation of the change in dose to the volume. Realistic patterns of motion can be applied to the structure to simulate inter-fraction motion and set-up error. The biologically effective dose for the structure is calculated for each fraction as the surface moves over the course of the treatment and is used to calculate the normal tissue complication probability (NTCP) or tumour control probability (TCP) for the moving structure. The tool has been used to evaluate conformal therapy plans against set up measurements recorded during patient treatments. NTCP and TCP were calculated for a patient whose set up had been corrected after systematic deviations from plan geometry were measured during treatment, the effect of not making the correction were also assessed. TCP for the moving tumour was reduced if inadequate margins were set for the treatment. Modelling suggests that smaller margins could have been set for the set up corrected during the course of the treatment. The NTCP for the rectum was also higher for the uncorrected set up due to a more rectal tissue falling in the high dose region. This approach provides a simple way for clinical users to utilise information incrementally collected throughout the whole of a patient's treatment. In particular it is possible to

  13. Monte Carlo Treatment Planning for Advanced Radiotherapy

    DEFF Research Database (Denmark)

    Cronholm, Rickard

    This Ph.d. project describes the development of a workflow for Monte Carlo Treatment Planning for clinical radiotherapy plans. The workflow may be utilized to perform an independent dose verification of treatment plans. Modern radiotherapy treatment delivery is often conducted by dynamically...... modulating the intensity of the field during the irradiation. The workflow described has the potential to fully model the dynamic delivery, including gantry rotation during irradiation, of modern radiotherapy. Three corner stones of Monte Carlo Treatment Planning are identified: Building, commissioning...... and validation of a Monte Carlo model of a medical linear accelerator (i), converting a CT scan of a patient to a Monte Carlo compliant phantom (ii) and translating the treatment plan parameters (including beam energy, angles of incidence, collimator settings etc) to a Monte Carlo input file (iii). A protocol...

  14. Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linac - testing IMRT to the limit?

    International Nuclear Information System (INIS)

    Webb, S.

    1999-01-01

    In this paper it is proposed that intensity-modulated radiotherapy (IMRT) could be delivered optimally by a short-length linac mounted on a robotic arm. The robot would allow the linac to 'plant' narrow pencils of photon radiation with any orientation (excluding zones within which the linac and couch might collide) relative to the planning target volume (PTV). The treatment is specified by the trajectory of the robot and by the number of monitor units (MUs) delivered at each robotic orientation. An inverse-planning method to determine the optimum robotic trajectory is presented. It is shown that for complex PTVs, specifically those with concavities in their outline, the conformality of the treatment is improved by the use of a complex trajectory in comparison with a less complex constrained trajectory and this improvement is quantified. It is concluded that robotic linac delivery would lead to a great flexibility in those IMRT treatments requiring very complicated dose distributions with complex 3D shapes. However, even using very fast computers, the goal of determining whether robotic linac delivery is the ultimate IMRT cannot be conclusively reached at present. (author)

  15. Three-dimensional conformal radiotherapy by delineations on CT-based simulation in different respiratory phases for the treatment of senile patients with non-small cell lung cancer.

    Science.gov (United States)

    Wang, Weifeng; Yuan, Feng; Wang, Guoping; Lin, Zhiren; Pan, Yanling; Chen, Longhua

    2015-01-01

    This study aimed to evaluate the application of three-dimensional conformal radiotherapy (3D-CRT) for elderly patients with non-small cell lung cancer (NSCLC) based on computed tomography (CT) simulations in different respiratory phases. A total of 64 patients aged >70 years old with NSCLC were treated by 3D-CRT using CT images in different respiratory phases. The gross tumor volumes (GTVs) at the end of inspiration and end of expiration were combined to obtain the total GTV, which was close to the motional range of tumors during respiration, and no additional expansion of the clinical target volume (CTAV) to planning target volume (PTV) (CTAV:PTV) was included during the recording of respiratory movements. Patients were also planned according to the classic 3D-CRT approach. Efficacy, prognostic factors, and side effects were evaluated. Compared with the classic approach, the average PTV was 18.9% lower (median: 17.3%), and the average lung volume receiving a prescribed dose for a tumor was 22.4% lower (median: 20.9%). The 1-, 2-, and 3-year survival rates were 70.6%, 54.9%, and 29.4%, respectively, with an overall tumor response rate of 79.7%. The Karnofsky performance status and N stage were independent prognostic factors, whereas age was not. Without affecting therapeutic effects, CT simulations in different respiratory phases were well-tolerated in elderly patients with NSCLC, could effectively reduce PTV, and could improve the quality of life.

  16. A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy

    International Nuclear Information System (INIS)

    Nutting, Christopher M.; Bedford, James L.; Cosgrove, Vivian P.; Tait, Diana M.; Dearnaley, David P.; Webb, Steve

    2001-01-01

    Background and purpose: To investigate the potential of intensity-modulated radiotherapy (IMRT) to reduce lung irradiation in the treatment of oesophageal carcinoma with radical radiotherapy. Materials and methods: A treatment planning study was performed to compare two-phase conformal radiotherapy (CFRT) with IMRT in five patients. The CFRT plans consisted of anterior, posterior and bilateral posterior oblique fields, while the IMRT plans consisted of either nine equispaced fields (9F), or four fields (4F) with orientations equal to the CFRT plans. IMRT plans with seven, five or three equispaced fields were also investigated in one patient. Treatment plans were compared using dose-volume histograms and normal tissue complication probabilities. Results: The 9F IMRT plan was unable to improve on the homogeneity of dose to the planning target volume (PTV), compared with the CFRT plan (dose range, 16.9±4.5 (1 SD) vs. 12.4±3.9%; P=0.06). Similarly, the 9F IMRT plan was unable to reduce the mean lung dose (11.7±3.2 vs. 11.0±2.9 Gy; P=0.2). Similar results were obtained for seven, five and three equispaced fields in the single patient studied. The 4F IMRT plan provided comparable PTV dose homogeneity with the CFRT plan (11.8±3.3 vs. 12.4±3.9%; P=0.6), with reduced mean lung dose (9.5±2.3 vs 11.0±2.9 Gy; P=0.001). Conclusions: IMRT using nine equispaced fields provided no improvement over CFRT. This was because the larger number of fields in the IMRT plan distributed a low dose over the entire lung. In contrast, IMRT using four fields equal to the CFRT fields offered an improvement in lung sparing. Thus, IMRT with a few carefully chosen field directions may lead to a modest reduction in pneumonitis, or allow tumour dose escalation within the currently accepted lung toxicity

  17. Intensity-modulated radiotherapy vs. parotid-sparing 3D conformal radiotherapy. Effect on outcome and toxicity in locally advanced head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, M.; Nevens, D.; Nuyts, S. [University Hospitals Leuven (Belgium). Dept. of Radiation Oncology

    2013-03-15

    Background and purpose: Intensity-modulated radiotherapy (IMRT) has rapidly become standard of care in the management of locally advanced head and neck squamous cell carcinoma (HNSCC). In this study, our aim was to retrospectively investigate the effect of the introducing IMRT on outcome and treatment-related toxicity compared to parotid-sparing 3D conformal radiotherapy (3DCRT). Material and methods: A total of 245 patients with stage III and IV HNSCC treated with primary radiotherapy between January 2003 and December 2010 were included in this analysis: 135 patients were treated with 3DCRT, 110 patients with IMRT. Groups were compared for acute and late toxicity, locoregional control (LRC), and overall survival (OS). Oncologic outcomes were estimated using Kaplan-Meier analysis and compared using a log-rank test. Acute toxicity was analyzed according to the Common Terminology Criteria for Adverse Events v3.0 and late toxicity was scored using the RTOG/EORTC late toxicity scoring system. Results: Median follow-up was 35 months in the IMRT group and 68 months in the 3DCRT group. No significant differences were found in 3-year LRC and OS rates between the IMRT group and 3DCRT group. Significantly less acute mucositis {>=} grade 3 was observed in the IMRT group (32% vs. 44%, p = 0.03). There was significantly less late xerostomia {>=} grade 2 in the IMRT group than in the 3DCRT group (23% vs. 68%, p < 0.001). After 24 months, there was less dysphagia {>=} grade 2 in the IMRT group although differences failed to reach statistical significance. Conclusion: The introduction of IMRT in the radiotherapeutic management of locally advanced head and neck cancer significantly improved late toxicity without compromising tumor control compared to a parotid-sparing 3D conformal radiotherapy technique. (orig.)

  18. Treatment results of adjuvant radiotherapy and salvage radiotherapy after radical prostatectomy for prostate cancer

    International Nuclear Information System (INIS)

    Wadasaki, Koichi; Kaneyasu, Yuko; Kenjo, Masahiro; Matsuura, Kanji; Murakami, Yuji; Hashimoto, Yasutoshi; Ito, Katsuhide; Kiriu, Hiroshi; Ito, Atsushi

    2007-01-01

    The indications for and the efficacy of radiation therapy after radical operation for patients with prostate cancer are not clear. We analyzed the treatment results of adjuvant radiotherapy and salvage radiotherapy after radical prostatectomy. Between September 1997 and November 2004, 57 patients received adjuvant radiotherapy or salvage radiotherapy after radical prostatectomy. Fifteen patients received radiation therapy because of positive margins and/or extracapsular invasion in surgical specimens (adjuvant group). Forty-two patients received radiation therapy because of rising prostate-specific antigen (PSA) during follow-up (salvage group). Radiation therapy was delivered to the fossa of the prostate±seminal vesicles by a three-dimensional (3-D) conformal technique to a total dose of 60-66 Gy (median, 60 Gy). Biochemical control was defined as the maintenance of a PSA level of less than 0.2 ng/ml. The median follow-up period after radiation therapy was 33 months (range, 12-98 months). Three-year biochemical control rates were 87% for the adjuvant group and 61% for the salvage group. For patients in the salvage group treated without hormone therapy, the preradiation PSA value was the most significant factor for the biochemical control rate. The 3-year biochemical control rate was 93% in patients whose preradiation PSA was 0.5 ng/ml or less and 29% in patients whose preradiation PSA was more than 0.5 ng/ml. No severe adverse effects (equal to or more than grade 3) were seen in treated patients. Radiation therapy after radical prostatectomy seemed to be effective for adjuvant therapy and for salvage therapy in patients with a preradiation PSA of 0.5 ng/ml or less. Also, radiation to the fossa of the prostate±seminal vesicles, to a total dose of 60-66 Gy, using a three-dimensional (3-D) conformal technique, seemed to be safe. (author)

  19. External beam radiotherapy of localized prostatic adenocarcinoma. Evaluation of conformal therapy, field number and target margins

    International Nuclear Information System (INIS)

    Lennernaes, B.; Rikner, G.; Letocha, H.; Nilsson, S.

    1995-01-01

    The purpose of the present study was to identify factors of importance in the planning of external beam radiotherapy of prostatic adenocarcinoma. Seven patients with urogenital cancers were planned for external radiotherapy of the prostate. Four different techniques were used, viz. a 4-field box technique and four-, five- or six-field conformal therapy set-ups combined with three different margins (1-3 cm). The evaluations were based on the doses delivered to the rectum and the urinary bladder. A normal tissue complication probability (NTCP) was calculated for each plan using Lyman's dose volume reduction method. The most important factors that resulted in a decrease of the dose delivered to the rectum and the bladder were the use of conformal therapy and smaller margins. Conformal therapy seemed more important for the dose distribution in the urinary bladder. Five- and six-field set-ups were not significantly better than those with four fields. NTCP calculations were in accordance with the evaluation of the dose volume histograms. To conclude, four-field conformal therapy utilizing reduced margins improves the dose distribution to the rectum and the urinary bladder in the radiotherapy of prostatic adenocarcinoma. (orig.)

  20. Cardiac Exposure in the Dynamic Conformal Arc Therapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy of Lung Cancer.

    Directory of Open Access Journals (Sweden)

    Xin Ming

    Full Text Available To retrospectively evaluate the cardiac exposure in three cohorts of lung cancer patients treated with dynamic conformal arc therapy (DCAT, intensity-modulated radiotherapy (IMRT, or volumetric modulated arc therapy (VMAT at our institution in the past seven years.A total of 140 lung cancer patients were included in this institutional review board approved study: 25 treated with DCAT, 70 with IMRT and 45 with VMAT. All plans were generated in a same commercial treatment planning system and have been clinically accepted and delivered. The dose distribution to the heart and the effects of tumor laterality, the irradiated heart volume and the beam-to-heart distance on the cardiac exposure were investigated.The mean dose to the heart among all 140 plans was 4.5 Gy. Specifically, the heart received on average 2.3, 5.2 and 4.6 Gy in the DCAT, IMRT and VMAT plans, respectively. The mean heart doses for the left and right lung tumors were 4.1 and 4.8 Gy, respectively. No patients died with evidence of cardiac disease. Three patients (2% with preexisting cardiac condition developed cardiac disease after treatment. Furthermore, the cardiac exposure was found to increase linearly with the irradiated heart volume while decreasing exponentially with the beam-to-heart distance.Compared to old technologies for lung cancer treatment, modern radiotherapy treatment modalities demonstrated better heart sparing. But the heart dose in lung cancer radiotherapy is still higher than that in the radiotherapy of breast cancer and Hodgkin's disease where cardiac complications have been extensively studied. With strong correlations of mean heart dose with beam-to-heart distance and irradiated heart volume, cautions should be exercised to avoid long-term cardiac toxicity in the lung cancer patients undergoing radiotherapy.

  1. Class solution to decrease rectal dose in prostate radiotherapy treatments 3D-CRT

    International Nuclear Information System (INIS)

    Andres Rodriguez, C.; Tortosa Oliver, R.; Alonso Hernandez, D.; Mari Palacios, A.; Castillo Belmonte, A. del

    2011-01-01

    This paper contains a method developed in our center with conventional 3D radiotherapy techniques to increase the dose conformation around the target volume in prostate cancer treatments significantly reduced the doses to the rectum. To evaluate the goodness of the method, the results are compared with two classical techniques of treatment.

  2. Treatment accuracy of fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Kumar, Shaleen; Burke, Kevin; Nalder, Colin; Jarrett, Paula; Mubata, Cephas; A'Hern, Roger; Humphreys, Mandy; Bidmead, Margaret; Brada, Michael

    2005-01-01

    Background and purpose: To assess the geometric accuracy of the delivery of fractionated stereotactic radiotherapy (FSRT) for brain tumours using the Gill-Thomas-Cosman (GTC) relocatable frame. Accuracy of treatment delivery was measured via portal images acquired with an amorphous silicon based electronic portal imager (EPI). Results were used to assess the existing verification process and to review the current margins used for the expansion of clinical target volume (CTV) to planning target volume (PTV). Patients and methods: Patients were immobilized in a GTC frame. Target volume definition was performed on localization CT and MRI scans and a CTV to PTV margin of 5 mm (based on initial experience) was introduced in 3D. A Brown-Roberts-Wells (BRW) fiducial system was used for stereotactic coordinate definition. The existing verification process consisted of an intercomparison of the coordinates of the isocentres and anatomy between the localization and verification CT scans. Treatment was delivered with 6 MV photons using four fixed non-coplanar conformal fields using a multi-leaf collimator. Portal imaging verification consisted of the acquisition of orthogonal images centred through the treatment isocentre. Digitally reconstructed radiographs (DRRs) created from the CT localization scans were used as reference images. Semi-automated matching software was used to quantify set up deviations (displacements and rotations) between reference and portal images. Results: One hundred and twenty six anterior and 123 lateral portal images were available for analysis for set up deviations. For displacements, the total errors in the cranial/caudal direction were shown to have the largest SD's of 1.2 mm, while systematic and random errors reached SD's of 1.0 and 0.7 mm, respectively, in the cranial/caudal direction. The corresponding data for rotational errors (the largest deviation was found in the sagittal plane) was 0.7 deg. SD (total error), 0.5 deg. (systematic) and 0

  3. Longitudinal Study of Intestinal Symptoms and Fecal Continence in Patients With Conformal Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Geinitz, Hans; Thamm, Reinhard; Keller, Monika; Astner, Sabrina T.; Heinrich, Christine; Scholz, Christian; Pehl, Christian; Kerndl, Simone; Prause, Nina; Busch, Raymonde; Molls, Michael; Zimmermann, Frank B.

    2011-01-01

    Purpose: To prospectively assess the intestinal symptoms and fecal continence in patients who had undergone conformal radiotherapy (CRT) for prostate cancer. Methods and Materials: A total of 78 men who had undergone definitive CRT for prostate cancer were evaluated. The patients were assessed before, during (treatment Weeks 4 and 6), and 2, 12, and 24 months after CRT completion. The intestinal symptoms and fecal continence were evaluated with comprehensive standardized questionnaires. Results: The intestinal symptoms were mostly intermittent, with only a small minority of patients affected daily. Defecation pain, fecal urge, and rectal mucous discharge increased significantly during therapy. Defecation pain and rectal mucous discharge had returned to baseline levels within 8 weeks and 1 year after CRT, respectively. However, fecal urge remained significantly elevated for ≤1 year and then returned toward the pretreatment values. The prevalence of rectal bleeding was significantly elevated 2 years after CRT. Fecal continence deteriorated during CRT and remained impaired at 1 year after treatment. Incontinence was mostly minor, occurring less than once per week and predominantly affecting incontinence for gas. Conclusion: Intestinal symptoms and fecal incontinence increased during prostate CRT. Except for rectal bleeding, the intestinal symptoms, including fecal incontinence, returned to baseline levels within 1-2 years after CRT. Thus, the rate of long-term late radiation-related intestinal toxicity was low.

  4. [Doses to organs at risk in conformational radiotherapy and stereotaxic irradiation: The heart].

    Science.gov (United States)

    Vandendorpe, B; Servagi Vernat, S; Ramiandrisoa, F; Bazire, L; Kirova, Y M

    2017-10-01

    Radiation therapy of breast cancer, Hodgkin lymphoma, lung cancer and others thoracic irradiations induce an ionizing radiation dose to the heart. Irradiation of the heart, associated with patient cardiovascular risk and cancer treatment-induced cardiotoxicity, increase cardiovascular mortality. The long survival after breast or Hodgkin lymphoma irradiation requires watching carefully late treatment toxicity. The over-risk of cardiac events is related to the dose received by the heart and the irradiated cardiac volume. The limitation of cardiac irradiation should be a priority in the planning of thoracic irradiations. Practices have to be modified, using modern techniques to approach of the primary objective of radiotherapy which is to optimize the dose to the target volume, sparing healthy tissues, in this case the heart. We have reviewed the literature on cardiac toxicity induced by conformational tridimensional radiation therapy, intensity-modulated radiation therapy or stereotactic body radiation therapy, in order to evaluate the possibilities to limit cardiotoxicity. Finally, we summarise the recommendations on dose constraints to the heart and coronary arteries. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  5. Conformal radiotherapy by intensity modulation of pediatrics tumors; Radiotherapie conformationnelle par modulation d'intensite des tumeurs pediatriques

    Energy Technology Data Exchange (ETDEWEB)

    Leseur, J.; Le Prise, E. [Centre Eugene-Marquis, 35 - Rennes (France); Carrie, C. [Centre Leon Berard, 69 - Lyon (France); Bernier, V. [Centre Alexis-Vautrin, 54 - Nancy (France); Beneyton, V. [Centre Paul-Strauss, 67 - Strasbourg (France); Mahe, M.A.; Supiot, S. [Centre Rene-Gauducheau, 44 - Nantes (France)

    2009-10-15

    The objective of this study is to take stock on the validated and potential indications of the conformal radiotherapy with intensity modulation ( intensity modulated radiotherapy I.M.R.T.) in pediatrics and to propose recommendations for its use as well as the adapted dose constraints. About 40 to 50% of children treated for a cancer are irradiated. The I.M.R.T., by linear accelerator or helical tomo-therapy has for aim to give a homogenous dose to the target volume and to save organs at risk. Its use in pediatrics seems particularly interesting because of the complexity of target volumes and the closeness of organs at risk. In compensation for these positive elements, the importance of low doses irradiation given in big volumes makes fear event consequences on growth and an increased incidence of secondary cancers in children suffering from tumors with high cure rates and long life expectancy. (N.C.)

  6. Three-Dimensional Conformal Simultaneously Integrated Boost Technique for Breast-Conserving Radiotherapy

    International Nuclear Information System (INIS)

    Laan, Hans Paul van der; Dolsma, Wil V.; Maduro, John H.; Korevaar, Erik W.; Hollander, Miranda; Langendijk, Johannes A.

    2007-01-01

    Purpose: To compare the target coverage and normal tissue dose with the simultaneously integrated boost (SIB) and the sequential boost technique in breast cancer, and to evaluate the incidence of acute skin toxicity in patients treated with the SIB technique. Methods and Materials: Thirty patients with early-stage left-sided breast cancer underwent breast-conserving radiotherapy using the SIB technique. The breast and boost planning target volumes (PTVs) were treated simultaneously (i.e., for each fraction, the breast and boost PTVs received 1.81 Gy and 2.3 Gy, respectively). Three-dimensional conformal beams with wedges were shaped and weighted using forward planning. Dose-volume histograms of the PTVs and organs at risk with the SIB technique, 28 x (1.81 + 0.49 Gy), were compared with those for the sequential boost technique, 25 x 2 Gy + 8 x 2 Gy. Acute skin toxicity was evaluated for 90 patients treated with the SIB technique according to Common Terminology Criteria for Adverse Events, version 3.0. Results: PTV coverage was adequate with both techniques. With SIB, more efficiently shaped boost beams resulted in smaller irradiated volumes. The mean volume receiving ≥107% of the breast dose was reduced by 20%, the mean volume outside the boost PTV receiving ≥95% of the boost dose was reduced by 54%, and the mean heart and lung dose were reduced by 10%. Of the evaluated patients, 32.2% had Grade 2 or worse toxicity. Conclusion: The SIB technique is proposed for standard use in breast-conserving radiotherapy because of its dose-limiting capabilities, easy implementation, reduced number of treatment fractions, and relatively low incidence of acute skin toxicity

  7. Preliminary results of three-dimensional conformal radiotherapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Wang Yingjie; Wang Luhua; Wang Xin; Feng Qinfu; Zhang Hongxing; Xiao Zefen; Yin Weibo

    2005-01-01

    Objective: To evaluate the therapeutic effects and complications of three-dimensional conformal radiotherapy (3DCRT) for non-small cell lung cancer (NSCLC). Methods: Between March 1999 and September 2003, 91 NSCLC patients treated with 3DCRT were reviewed at the Cancer Hospital, Chinese Academy of Medical Sciences. This patient cohort consisted of 73 men and 18 women. The median age was 66 years. Radio-therapy was delivered at 2 Gy fraction, 5 fractions per week. The median total dose was 60 Gy. Results: With a median follow-up time of 17 months, the response rate after 3DCRT was 57.1%, with complete remission 11.0% (10/91) and partial remission 46.2%(42/91). The median survival time (MST) was 16 months, with 1- and 2- year overall survivals (OS) of 67.0% and 32.6%, 1- and 2-year local progression free survivals (LPFS) of 82.6% and 53.0%, respectively. The independent adverse prognostic factors by univariate analysis and multivariate analysis was weight loss ≥5%. Grade 2 acute radiation pneumonitis was observed in 2 patients and grade 3 in 4 patients. Late lung injury developed in 1 patient with grade 2, 1 patient with grade 3, respectively. Acute radiation esophagitis was observed in 8 patients with grade 2. Acute grade 2 hematologic toxicity developed in 5 patients. Conclusions: 3DCRT was feasible in the treatment of NSCLC with good immediate tumor response and acceptable normal tissue complication. The total dose may potentially be increased. (authors)

  8. Limited Advantages of Intensity-Modulated Radiotherapy Over 3D Conformal Radiation Therapy in the Adjuvant Management of Gastric Cancer

    International Nuclear Information System (INIS)

    Alani, Shlomo; Soyfer, Viacheslav; Strauss, Natan; Schifter, Dan; Corn, Benjamin W.

    2009-01-01

    Purpose: Although chemoradiotherapy was considered the standard adjuvant treatment for gastric cancer, a recent Phase III trial (Medical Research Council Adjuvant Gastric Infusional Chemotherapy [MAGIC]) did not include radiotherapy in the randomization scheme because it was considered expendable. Given radiotherapy's potential, efforts needed to be made to optimize its use for treating gastric cancer. We assessed whether intensity-modulated radiotherapy (IMRT) could improve upon our published results in patients treated with three-dimensional (3D) conformal therapy. Methods and Materials: Fourteen patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a noncoplanar four-field arrangement. Subsequently, a nine-field IMRT plan was designed using a CMS Xio IMRT version 4.3.3 module. Two IMRT beam arrangements were evaluated: beam arrangement 1 consisted of gantry angles of 0 deg., 53 deg., 107 deg., 158 deg., 204 deg., 255 deg., and 306 deg.. Beam arrangement 2 consisted of gantry angles of 30 deg., 90 deg., 315 deg., and 345 deg.; a gantry angle of 320 deg./couch, 30 deg.; and a gantry angle of 35 o /couch, 312 o . Both the target volume coverage and the dose deposition in adjacent critical organs were assessed in the plans. Dose-volume histograms were generated for the clinical target volume, kidneys, spine, and liver. Results: Comparison of the clinical target volumes revealed satisfactory coverage by the 95% isodose envelope using either IMRT or 3D conformal therapy. However, IMRT was only marginally better than 3D conformal therapy at protecting the spine and kidneys from radiation. Conclusions: IMRT confers only a marginal benefit in the adjuvant treatment of gastric cancer and should be used only in the small subset of patients with risk factors for kidney disease or those with a preexisting nephropathy.

  9. Limited advantages of intensity-modulated radiotherapy over 3D conformal radiation therapy in the adjuvant management of gastric cancer.

    Science.gov (United States)

    Alani, Shlomo; Soyfer, Viacheslav; Strauss, Natan; Schifter, Dan; Corn, Benjamin W

    2009-06-01

    Although chemoradiotherapy was considered the standard adjuvant treatment for gastric cancer, a recent Phase III trial (Medical Research Council Adjuvant Gastric Infusional Chemotherapy [MAGIC]) did not include radiotherapy in the randomization scheme because it was considered expendable. Given radiotherapy's potential, efforts needed to be made to optimize its use for treating gastric cancer. We assessed whether intensity-modulated radiotherapy (IMRT) could improve upon our published results in patients treated with three-dimensional (3D) conformal therapy. Fourteen patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a noncoplanar four-field arrangement. Subsequently, a nine-field IMRT plan was designed using a CMS Xio IMRT version 4.3.3 module. Two IMRT beam arrangements were evaluated: beam arrangement 1 consisted of gantry angles of 0 degrees , 53 degrees , 107 degrees , 158 degrees , 204 degrees , 255 degrees , and 306 degrees . Beam arrangement 2 consisted of gantry angles of 30 degrees , 90 degrees , 315 degrees , and 345 degrees ; a gantry angle of 320 degrees /couch, 30 degrees ; and a gantry angle of 35 degrees /couch, 312 degrees . Both the target volume coverage and the dose deposition in adjacent critical organs were assessed in the plans. Dose-volume histograms were generated for the clinical target volume, kidneys, spine, and liver. Comparison of the clinical target volumes revealed satisfactory coverage by the 95% isodose envelope using either IMRT or 3D conformal therapy. However, IMRT was only marginally better than 3D conformal therapy at protecting the spine and kidneys from radiation. IMRT confers only a marginal benefit in the adjuvant treatment of gastric cancer and should be used only in the small subset of patients with risk factors for kidney disease or those with a preexisting nephropathy.

  10. Conformal radiotherapy for prostate cancer: contribution of pelvic immobilization and new fiducial markers

    International Nuclear Information System (INIS)

    Garcia, R.; Oozeer, R.; Le Thanh, H.; Chauvet, B.; Toy, B.J.; Reboul, F.

    1997-01-01

    To reduce errors in the positioning of patients treated with external conformal radiotherapy for prostate cancer, we evaluated both the use of an immobilization device and new fiducial markers. The immobilization device consisted of an individual mold made of polyurethane foam. Two sets of skin markers located on the anterior tibial surfaces were used to identify the pelvic isocenter. The patient's position was evaluated by orthogonal port film which were then compared with the original simulation film. Results are presented with respect to orthogonal axes. Comparison with classic procedures without immobilization showed that use of the mold and new fiducial markers led to a decrease in set-up errors which were less than 5 mm. With the use of an immobilization device and optimized techniques for patients' positioning, conformal radiotherapy of prostate cancer is more accurate. (authors)

  11. Development of model plans in three dimensional conformal radiotherapy for brain tumors

    International Nuclear Information System (INIS)

    Pyo, Hongryull; Kim, Gwieon; Keum, Kichang; Chang, Sekyung; Suh, Changok; Lee, Sanghoon

    2002-01-01

    Three dimensional conformal radiotherapy planning is being used widely for the treatment of patients with brain tumor. However, it takes much time to develop an optimal treatment plan, therefore, it is difficult to apply this technique to all patients. To increase the efficiency of this technique, we need to develop standard radiotherapy plans for each site of the brain. Therefore we developed several 3 dimensional conformal radiotherapy plans (3D plans) for tumors at each site of brain, compared them with each other, and with 2 dimensional radiotherapy plans. Finally model plans for each site of the brain were decided. Imaginary tumors, with sizes commonly observed in the clinic, were designed for each site of the brain and drawn on CT images. The planning target volumes (PTVs) were as follows; temporal tumor-5.7 x 8.2 x 7.6 cm, suprasellar tumor-3 x 4 x 4.1 cm, thalamic tumor-3.1 x 5.9 x 3.7 cm, frontoparietal tumor-5.5 x 7 x 5.5 cm, and occipitoparietal tumor-5 x 5.5 x 5 cm. Plans using parallel opposed 2-portals and/or 3 portals including fronto-vertex and 2 lateral fields were developed manually as the conventional 2D plans, and 3D noncoplanar conformal plans were developed using beam's eye view and the automatic block drawing tool. Total tumor dose was 54 Gy for a suprasellar tumor, 59.4 Gy and 72 Gy for the other tumors. All dose plans (including 2D plans) were calculated using 3D plan software. Developed plans were compared with each other using dose-volume histograms (DVH), normal tissue complication probabilities (NTCP) and variable dose statistic values (minimum, maximum and mean dose, D5, V83, V85 and V95). Finally a best radiotherapy plan for each site of brain was selected. 1) Temporal tumor; NTCPs and DVHs of the normal tissue of all 3D plans were superior to 2D plans and this trend was more definite when total dose was escalated to 72 Gy (NTCPs of normal brain 2D plans: 27%, 8% → 3D plans: 1%, 1%). Various dose statistic values did not show any

  12. Oral verrucous carcinoma. Treatment with radiotherapy

    International Nuclear Information System (INIS)

    Nair, M.K.; Sankaranarayanan, R.; Padmanabhan, T.K.; Madhu, C.S.

    1988-01-01

    Fifty-two cases of oral verrucous carcinoma treated with radiotherapy at the Regional Cancer Centre, Trivandrum, Kerala, India in 1982 were evaluated to determine the distribution within the oral cavity, clinical extent, and effectiveness of radiotherapy in controlling the disease. The most common site was the buccal mucosa. Fifty percent of the patients had clinically negative regional lymph nodes and 33% were in earlier stages (T1, T2, N0, and M0). The overall 3-year no evidence of disease (NED) survival rate was 44%. The 3-year NED survival rate with radium implant was 86%. We cannot comment on anaplastic transformation after radiotherapy because our treatment failures have not been subjected for biopsy concerning this matter. Because the results are comparable with those of well-differentiated squamous cell carcinoma, we think that the treatment policies advocated for oral squamous cell carcinoma are also applicable to oral verrucous carcinoma

  13. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    OpenAIRE

    Daniel L Saenz; Bhudatt R Paliwal; John E Bayouth

    2014-01-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This ...

  14. A deterministic iterative least-squares algorithm for beam weight optimization in conformal radiotherapy

    International Nuclear Information System (INIS)

    Chen Yan; Michalski, Darek; Houser, Christopher; Galvin, James M.

    2002-01-01

    Currently, inverse treatment planning in conformal radiotherapy is, in part, a trial-and-error process due to the interplay of many competing criteria for obtaining a clinically acceptable dose distribution. A new method is developed for beam weight optimization that incorporates clinically relevant nonlinear and linear constraints. The process is driven by a nonlinear, quasi-quadratic objective function and the solution space is defined by a set of linear constraints. At each step of iteration, the optimization problem is linearized by a self-consistent approximation that is local to the existing dose distribution. The dose distribution is then improved by solving a series of constrained least-squares problems using an established method until all prescribed constraints are satisfied. This differs from the current approaches in that it does not rely on the search for the global minimum of a specific objective function. Essentially, our proposed objective function can be construed as a functional that comprises a class of dose-based quadratic objective functions. Empirical adjustment for appropriate model parameters in the construction of objective function is minimized, since these parameters are in effect adaptively adjusted during optimization. The method is robust in solving difficult clinical cases using either aperture or pencil beam based planning techniques for intensity-modulated radiation therapy. (author)

  15. Simultaneous optimization of beam orientations and beam weights in conformal radiotherapy

    International Nuclear Information System (INIS)

    Rowbottom, Carl Graham; Khoo, Vincent S.; Webb, Steve

    2001-01-01

    A methodology for the concurrent optimization of beam orientations and beam weights in conformal radiotherapy treatment planning has been developed and tested on a cohort of five patients. The algorithm is based on a beam-weight optimization scheme with a downhill simplex optimization engine. The use of random voxels in the dose calculation provides much of the required speed up in the optimization process, and allows the simultaneous optimization of beam orientations and beam weights in a reasonable time. In the implementation of the beam-weight optimization algorithm just 10% of the original patient voxels are used for the dose calculation and cost function evaluation. A fast simulated annealing algorithm controls the optimization of the beam arrangement. The optimization algorithm was able to produce clinically acceptable plans for the five patients in the cohort study. The algorithm equalized the dose to the optic nerves compared to the standard plans and reduced the mean dose to the brain stem by an average of 4.4% (±1.9, 1 SD), p value=0.007. The dose distribution to the PTV was not compromised by developing beam arrangements via the optimization algorithm. In conclusion, the simultaneous optimization of beam orientations and beam weights has been developed to be routinely used in a realistic time. The results of optimization in a small cohort study show that the optimization can reliably produce clinically acceptable dose distributions and may be able to improve dose distributions compared to those from a human planner

  16. Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linac-conformality versus efficiency of dose delivery

    International Nuclear Information System (INIS)

    Webb, Steve

    2000-01-01

    Intensity-modulated radiotherapy (IMRT) may be delivered with a high-energy-photon linac mounted on a robotic gantry and executing a complex trajectory. In a previous paper an inverse-planning technique was developed for such an application. Here the work is extended to demonstrate the dependence of conformality on the size of the elemental pencil beam, on the complexity of the trajectory and on the sampling of azimuth and elevation of the collimated source. The improved conformality of complex trajectories is demonstrated and benchmarked relative to simpler trajectories, more representative of existing non-robotic IMRT techniques. Specifically, by choosing a very fine pencil beam, exquisitely conformal dose distributions have been obtained. Important sampling considerations have been determined. Expressions have been derived for the dosimetry and monitor-unit efficiency of robotic IMRT. Equivalent trajectories were computed for executing the complex robotic trajectories instead by using a conventional linac. The work benchmarks an ideal in IMRT against which more practical and more common techniques may be measured. (author)

  17. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy.

    NARCIS (Netherlands)

    Smeenk, R.J.; Lin, E.N.J.T. van; Kollenburg, P. van; Kunze-Busch, M.C.; Kaanders, J.H.A.M.

    2009-01-01

    BACKGROUND AND PURPOSE: To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. MATERIALS AND METHODS: In 24 patients with localized prostate carcinoma, two planning

  18. Conformal radiotherapy made easy through gravity oriented absorbers

    International Nuclear Information System (INIS)

    Proimos, B.S.

    1995-01-01

    In the 50's and the 60's simple techniques modulating the beam intensity in synchronism with the rotation, either of the vertical patient or of the machine around the horizontal patient were developed. An absorber, which is similar in shape to a vital organ, intercepts the beam, casting its protective 'shade' over the organ, for all positions of rotation. In this way, the organ is protected during the irradiation time. On any transverse cross, any point outside of the organ's cross-section is protected for only a fraction of T, which is decreasing with the distance of that point from the organ. Consequently, the dose to the protected organ is smaller than (a) the dose it would absorb without protection (b) the dose to the surrounding (less vital) healthy tissue and (c), the dose to the neighbouring tumour. Consider a plane perpendicular to the principal plane and passing through the source. It cuts the organ and its protector in two cross-sections, which remain always homiotheta, with centre of homiothesis the source. In this way, the protector's cross-section is projected by the beam on the organ's cross-section for all positions of rotation. The larger the cross-section of the organ and the smaller the required protection, the smaller must be the attenuation coefficient of the material the protector is made of. The dose distributions in a series of actual cases, such as head tumours with eyes protection, neck or chest tumours with spinal cord protection, cervix tumours with rectum and bladder protection, are discussed. In most cases, if the vital organs are not overprotected, the 90% or 80% isodose surface fits to or conforms with the surface of the Planning Target Volume (PTV) no matter how irregular (convex and concave) it is

  19. Conformal radiotherapy made easy through gravity oriented absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Proimos, B S [Patras Univ. (Greece). Dept. of Medical Physics

    1995-12-01

    In the 50`s and the 60`s simple techniques modulating the beam intensity in synchronism with the rotation, either of the vertical patient or of the machine around the horizontal patient were developed. An absorber, which is similar in shape to a vital organ, intercepts the beam, casting its protective `shade` over the organ, for all positions of rotation. In this way, the organ is protected during the irradiation time. On any transverse cross, any point outside of the organ`s cross-section is protected for only a fraction of T, which is decreasing with the distance of that point from the organ. Consequently, the dose to the protected organ is smaller than (a) the dose it would absorb without protection (b) the dose to the surrounding (less vital) healthy tissue and (c), the dose to the neighbouring tumour. Consider a plane perpendicular to the principal plane and passing through the source. It cuts the organ and its protector in two cross-sections, which remain always homiotheta, with centre of homiothesis the source. In this way, the protector`s cross-section is projected by the beam on the organ`s cross-section for all positions of rotation. The larger the cross-section of the organ and the smaller the required protection, the smaller must be the attenuation coefficient of the material the protector is made of. The dose distributions in a series of actual cases, such as head tumours with eyes protection, neck or chest tumours with spinal cord protection, cervix tumours with rectum and bladder protection, are discussed. In most cases, if the vital organs are not overprotected, the 90% or 80% isodose surface fits to or conforms with the surface of the Planning Target Volume (PTV) no matter how irregular (convex and concave) it is.

  20. Radiotherapy

    Directory of Open Access Journals (Sweden)

    Rema Jyothirmayi

    1999-01-01

    Full Text Available Purpose. Conservative treatment in the form of limited surgery and post-operative radiotherapy is controversial in hand and foot sarcomas, both due to poor radiation tolerance of the palm and sole, and due to technical difficulties in achieving adequate margins.This paper describes the local control and survival of 41 patients with soft tissue sarcoma of the hand or foot treated with conservative surgery and radiotherapy. The acute and late toxicity of megavoltage radiotherapy to the hand and foot are described. The technical issues and details of treatment delivery are discussed. The factors influencing local control after radiotherapy are analysed.

  1. Radiotherapy equipment for conformal radiotherapy and IMRT in the Czech Republic

    International Nuclear Information System (INIS)

    Horakova, I.; Irena Pavlikova, I.; Novotny, J. ml.

    2005-01-01

    The development of the equipment of radiotherapy departments in the Czech Republic is presented here. The data from the special questionnaire from 14 workplaces with linear accelerators with multi-leaf collimators (MLC) and electronic portal imaging device (EPID) are included. They show not only the equipment specification but also the application methods, the quality control, plans for future etc. In the Czech Republic, a great extension of modem irradiation techniques and accessories occurs at present. Together with it, it is necessary to develop quality assurance of the whole process of dose delivery to the patient. It is also necessary to assure further education and training of hospital staff. Modern radiotherapy techniques demand sufficient amount of all sources including personal sources. (authors)

  2. Radiotherapy in the treatment of solitary plasmacytoma.

    Science.gov (United States)

    Jyothirmayi, R; Gangadharan, V P; Nair, M K; Rajan, B

    1997-05-01

    Solitary plasmacytoma of bone (SPB) and extramedullary plasmacytoma (EMP) are rare. High local control rates are reported with radiotherapy, although the optimal dose and extent of radiotherapy portals remains controversial. Between 1983 and 1993, 30 patients with solitary plasmacytoma were seen at the Regional Cancer Centre, Trivandrum, India. 23 patients had SPB and seven EMP. The mean age was 52 years and the male to female ratio 3.2:1. Diagnosis of SPB was confirmed by biopsy in 16 patients and tumour excision in seven. 20 patients received megavoltage radiotherapy to the bone lesion with limited margins, and one received chemotherapy. Two patients who underwent complete tumour excision received no further treatment. All seven patients with EMP received megavoltage radiotherapy, four following biopsy and three after tumour excision. Local control was achieved in all patients with SPB. Nine progressed to multiple myeloma and one developed a solitary plasmacytoma in another bone. Six patients with EMP achieved local control. Three later progressed to multiple myeloma and one had local relapse. Median time to relapse was 28 months in SPB and 30 months in EMP. 5-year overall survival rates were 82% and 57% for patients with SPB and EMP, respectively. The corresponding progression free survival rates were 55% and 50%, respectively. Age, sex, site of tumour, serum M protein and haemoglobin levels did not significantly influence progression free survival. The extent of surgery, radiotherapy dose or time to relapse were not significant prognostic factors. Radiotherapy appears to be an effective modality of treatment of solitary plasmacytoma. No dose-response relationship is observed, and high local control rates are achieved with limited portals. Progression to multiple myeloma is the commonest pattern of failure, although no prognostic factors for progression are identified. The role of chemotherapy in preventing disease progression needs further evaluation.

  3. Hypofractionated conformal radiotherapy (HCRT) for primary and metastatic lung cancers with small dimension. Efficacy and toxicity

    International Nuclear Information System (INIS)

    Mirri, Maria Alessandra; Arcangeli, Giorgio; Pinzi, Valentina; Benassi, Marcello; D'Angelo, Annelisa; Strigari, Lidia; Caterino, Mauro; Rinaldi, Massimo; Ceribelli, Anna

    2009-01-01

    Purpose: to report on the clinical outcome of hypofractionated conformal radiotherapy (HCRT) for medically inoperable stage I non-small cell lung carcinoma (NSCLC) or limited pulmonary metastases ≤ 5 cm in diameter. Patients and methods: from June 2003 to March 2007, 40 patients (42 lesions) underwent HCRT consisting of 40 Gy in five fractions over 2.5 weeks received by at least 95% of planning target volume. All patients underwent CT simulation and treatment under free shallow breathing. To evaluate target displacement under respiratory activity, two additional CT scans were performed with breath-holding during the expiratory and inspiratory phases. Of all patients enrolled, those with a follow-up ≥ 4 months were considered suitable for analysis. Local response was evaluated with CT imaging 4 months after the end of HCRT and every 3 months thereafter. Local relapse-free survival (LRFS) and overall survival (OS) were calculated with the Kaplan-Meier method. Results: local response to the treatment was complete response, partial response, no change, and progressive disease as seen in 29%, 43%, 14%, and 7% of tumors, respectively. LRFS at 1 year and 3 years was 76% and 63%, respectively. Lung toxicities ≥ grade 2 were observed in 4/40 patients, but no grade 4. Pericardial effusion occurred in one patient. In stage I NSCLC patients (n = 15) with a median follow-up of 25 months, the 1-year LRFS and OS rates were 88% and 81%, respectively, and the 3-year rates 72% and 61%, respectively. Conclusion: HCRT is an effective and low-toxic treatment for medically inoperable early-stage lung cancers and pulmonary metastases for all clinicians lacking the aid of a dedicated stereotactic system. (orig.)

  4. Persistently better treatment planning results of intensity-modulated (IMRT) over conformal radiotherapy (3D-CRT) in prostate cancer patients with significant variation of clinical target volume and/or organs-at-risk

    International Nuclear Information System (INIS)

    Fenoglietto, Pascal; Laliberte, Benoit; Allaw, Ali; Ailleres, Norbert; Idri, Katia; Hay, Meng Huor; Moscardo, Carmen Llacer; Gourgou, Sophie; Dubois, Jean-Bernard; Azria, David

    2008-01-01

    Purpose: To compare the dose coverage of planning and clinical target volume (PTV, CTV), and organs-at-risk (OAR) between intensity-modulated (3D-IMRT) and conventional conformal radiotherapy (3D-CRT) before and after internal organ variation in prostate cancer. Methods and materials: We selected 10 patients with clinically significant interfraction volume changes. Patients were treated with 3D-IMRT to 80 Gy (minimum PTV dose of 76 Gy, excluding rectum). Fictitious, equivalent 3D-CRT plans (80 Gy at isocenter, with 95% isodose (76 Gy) coverage of PTV, with rectal blocking above 76 Gy) were generated using the same planning CT data set ('CT planning'). The plans were then also applied to a verification CT scan ('CT verify') obtained at a different moment. PTV, CTV, and OAR dose coverage were compared using non-parametric tests statistics for V95, V90 (% of the volume receiving ≥95 or 90% of the dose) and D50 (dose to 50% of the volume). Results: Mean V95 of the PTV for 'CT planning' was 94.3% (range, 88-99) vs 89.1% (range, 84-94.5) for 3D-IMRT and 3D-CRT (p = 0.005), respectively. Mean V95 of the CTV for 'CT verify' was 97% for both 3D-IMRT and 3D-CRT. Mean D50 of the rectum for 'CT planning' was 26.8 Gy (range, 22-35) vs 43.5 Gy (range, 33.5-50.5) for 3D-IMRT and 3D-CRT (p = 0.0002), respectively. For 'CT verify', this D50 was 31.1 Gy (range, 16.5-44) vs 44.2 Gy (range, 34-55) for 3D-IMRT and 3D-CRT (p = 0.006), respectively. V95 of the rectum was 0% for both plans for 'CT planning', and 2.3% (3D-IMRT) vs 2.1% (3D-CRT) for 'CT verify' (p = non-sig.). Conclusion: Dose coverage of the PTV and OAR was better with 3D-IMRT for each patient and remained so after internal volume changes

  5. Radiotherapy treatment planning linear-quadratic radiobiology

    CERN Document Server

    Chapman, J Donald

    2015-01-01

    Understand Quantitative Radiobiology from a Radiation Biophysics PerspectiveIn the field of radiobiology, the linear-quadratic (LQ) equation has become the standard for defining radiation-induced cell killing. Radiotherapy Treatment Planning: Linear-Quadratic Radiobiology describes tumor cell inactivation from a radiation physics perspective and offers appropriate LQ parameters for modeling tumor and normal tissue responses.Explore the Latest Cell Killing Numbers for Defining Iso-Effective Cancer TreatmentsThe book compil

  6. Comparison of Toxicity Between Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy for Locally Advanced Non-small-cell Lung Cancer.

    Science.gov (United States)

    Ling, Diane C; Hess, Clayton B; Chen, Allen M; Daly, Megan E

    2016-01-01

    The role of intensity-modulated radiotherapy (IMRT) in reducing treatment-related toxicity for locally advanced non-small-cell lung cancer (NSCLC) remains incompletely defined. We compared acute toxicity and oncologic outcomes in a large cohort of patients treated with IMRT or 3-dimensional conformal radiotherapy (3-DCRT), with or without elective nodal irradiation (ENI). A single-institution retrospective review was performed evaluating 145 consecutive patients with histologically confirmed stage III NSCLC treated with definitive chemoradiotherapy. Sixty-five (44.8%) were treated with 3-DCRT using ENI, 43 (30.0%) with 3-DCRT using involved-field radiotherapy (IFRT), and 37 (25.5%) with IMRT using IFRT. All patients received concurrent chemotherapy. Comparison of acute toxicities by treatment technique (IMRT vs. 3-DCRT) and extent of nodal irradiation (3-DCRT-IFRT vs. 3-DCRT-ENI) was performed for grade 2 or higher esophagitis or pneumonitis, number of acute hospitalizations, incidence of opioid requirement, percutaneous endoscopic gastrostomy utilization, and percentage weight loss during treatment. Local control and overall survival were analyzed by the Kaplan-Meier method. We identified no significant differences in any measures of acute toxicity by treatment technique or extent of nodal irradiation. There was a trend toward lower rates of grade 2 or higher pneumonitis among IMRT patients compared to 3-DCRT patients (5.4% vs. 23.0%; P = .065). Local control and overall survival were similar between cohorts. Acute and subacute toxicities were similar for patients treated with IMRT and with 3-DCRT with or without ENI, with a nonsignificant trend toward a reduction in pneumonitis with IMRT. Larger studies are needed to better define which patients will benefit from IMRT. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Improvement in toxicity in high risk prostate cancer patients treated with image-guided intensity-modulated radiotherapy compared to 3D conformal radiotherapy without daily image guidance.

    Science.gov (United States)

    Sveistrup, Joen; af Rosenschöld, Per Munck; Deasy, Joseph O; Oh, Jung Hun; Pommer, Tobias; Petersen, Peter Meidahl; Engelholm, Svend Aage

    2014-02-04

    Image-guided radiotherapy (IGRT) facilitates the delivery of a very precise radiation dose. In this study we compare the toxicity and biochemical progression-free survival between patients treated with daily image-guided intensity-modulated radiotherapy (IG-IMRT) and 3D conformal radiotherapy (3DCRT) without daily image guidance for high risk prostate cancer (PCa). A total of 503 high risk PCa patients treated with radiotherapy (RT) and endocrine treatment between 2000 and 2010 were retrospectively reviewed. 115 patients were treated with 3DCRT, and 388 patients were treated with IG-IMRT. 3DCRT patients were treated to 76 Gy and without daily image guidance and with 1-2 cm PTV margins. IG-IMRT patients were treated to 78 Gy based on daily image guidance of fiducial markers, and the PTV margins were 5-7 mm. Furthermore, the dose-volume constraints to both the rectum and bladder were changed with the introduction of IG-IMRT. The 2-year actuarial likelihood of developing grade > = 2 GI toxicity following RT was 57.3% in 3DCRT patients and 5.8% in IG-IMRT patients (p analysis, 3DCRT was associated with a significantly increased risk of developing grade > = 2 GI toxicity compared to IG-IMRT (p analysis there was no difference in biochemical progression-free survival between 3DCRT and IG-IMRT. The difference in toxicity can be attributed to the combination of the IMRT technique with reduced dose to organs-at-risk, daily image guidance and margin reduction.

  8. A strategy to correct for intrafraction target translation in conformal prostate radiotherapy: Simulation results

    International Nuclear Information System (INIS)

    Keall, P. J.; Lauve, A. D.; Hagan, M. P.; Siebers, J. V.

    2007-01-01

    simulated internal motion shifts. Dose increases for adjacent organs at risk were rare. D 33 of the rectum and D 20 of the bladder were increased by more than 5% of the prescription dose in 9 and 1 instances of the 3600 sampled internal motion shifts, respectively. D mean of the right femoral head increased by more than 5% of the prescription dose in 651 (18%) internal motion shifts, predominantly due to the projection of the lateral beams through the femoral head for anterior prostate motion. However, D 2 was not increased by more than 5% for any of the internal motion shifts. These data demonstrate the robustness of the proposed dynamic compensation strategy for correction of internal motion in conformal prostate radiotherapy, with minimal deviation from the original treatment plans even for errors exceeding those commonly encountered in the clinic. The compensation strategy could be performed automatically with appropriate enhancements to available delivery software

  9. Strategies to evaluate the impact of rectal volume on prostate motion during three-dimensional conformal radiotherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Poli, Ana Paula Diniz Fortuna, E-mail: anapaulafortuna@yahoo.com.br [Universidade Estadual de Campinas (CAISM/UNICAMP), Campinas, SP (Brazil). Centro de Atencao Integrada a Saude da Mulher. Divisao de Radioterapia; Dias, Rodrigo Souza; Giordani, Adelmo Jose; Segreto, Helena Regina Comodo; Segreto, Roberto Araujo [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Divisao de Radioterapia

    2016-01-15

    Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation (p = 0.037). A baseline rectal volume superior to 70 cm{sup 3} had a significant influence on the prostate motion in the anteroposterior direction (p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm{sup 3}. Therefore, the treatment of patients with a rectal volume > 70 cm{sup 3} should be re-planned with appropriate rectal preparation. Keywords: Rectal volume; Prostate cancer; Three-dimensional conformal radiotherapy. (author)

  10. Transabdominal ultrasonography, computed tomography and electronic portal imaging for 3-dimensional conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Jereczek-Fossa, B.A.; Orecchia, R.; Cattani, F.; Garibaldi, C.; Cambria, R.; Valenti, M.; Ciocca, M.; Zerini, D.; Boboc, G.I.; Vavassori, A.; Ivaldi, G.B.; Kowalczyk, A.; Matei, D.V.; Cobelli, O. de

    2007-01-01

    Purpose: To evaluate the feasibility and accuracy of daily B-mode acquisition and targeting ultrasound-based prostate localization (BAT trademark) and to compare it with computed tomography (CT) and electronic portal imaging (EPI) in 3-dimensional conformal radiotherapy (3-D CRT) for prostate cancer. Patients and Methods: Ten patients were treated with 3-D CRT (72 Gy/30 fractions, 2.4 Gy/fraction, equivalent to 80 Gy/40 fractions, for α/β ratio of 1.5 Gy) and daily BAT-based prostate localization. For the first 5 fractions, CT and EPI were also performed in order to compare organ-motion and set-up error, respectively. Results: 287 BAT-, 50 CT- and 46 EPI-alignments were performed. The average BAT-determined misalignments in latero-lateral, antero-posterior and cranio-caudal directions were -0.9 mm ± 3.3 mm, 1.0 mm ± 4.0 mm and -0.9 mm ± 3.8 mm, respectively. The differences between BAT- and CT-determined organ-motion in latero-lateral, antero-posterior and cranio-caudal directions were 2.7 mm ± 1.9 mm, 3.9 ± 2.8 mm and 3.4 ± 3.0 mm, respectively. Weak correlation was found between BAT- and CT-determined misalignments in antero-posterior direction, while no correlation was observed in latero-lateral and cranio-caudal directions. The correlation was more significant when only data of good image-quality patients were analyzed (8 patients). Conclusion: BAT ensures the relative positions of target are the same during treatment and in treatment plan, however, the reliability of alignment is patient-dependent. The average BAT-determined misalignments were small, confirming the prevalence of random errors in 3-D CRT. Further study is warranted in order to establish the clinical value of BAT. (orig.)

  11. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy

    International Nuclear Information System (INIS)

    Smeenk, Robert Jan; Lin, Emile N.J.Th. van; Kollenburg, Peter van; Kunze-Busch, Martina; Kaanders, Johannes H.A.M.

    2009-01-01

    Background and purpose: To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. Materials and methods: In 24 patients with localized prostate carcinoma, two planning CT-scans were performed: with and without ERB. A prostate planning target volume (PTV) was defined, and the Awall was delineated, using two different methods. Three-field and 4-field 3D-CRT plans, and IMRT plans were generated with a prescription dose of 78 Gy. In 144 treatment plans, the minimum dose (D min ), maximum dose (D max ), and mean dose (D mean ) to the Awall were calculated, as well as the Awall volumes exposed to doses ranging from ≥20 Gy to ≥70 Gy (V 20 - V 70 , respectively). Results: In the 3D-CRT plans, an ERB significantly reduced D mean , D max , and V 30 - V 70 . For IMRT all investigated dose parameters were significantly reduced by the ERB. The absolute reduction of D mean was 12 Gy in 3D-CRT and was 7.5 Gy in IMRT for both methods of Awall delineation. Conclusions: Application of an ERB showed a significant Awall sparing effect in both 3D-CRT and IMRT. This may lead to reduced late anal toxicity in prostate radiotherapy.

  12. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy.

    Science.gov (United States)

    Smeenk, Robert Jan; van Lin, Emile N J Th; van Kollenburg, Peter; Kunze-Busch, Martina; Kaanders, Johannes H A M

    2009-10-01

    To investigate the anal wall (Awall) sparing effect of an endorectal balloon (ERB) in 3D conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) for prostate cancer. In 24 patients with localized prostate carcinoma, two planning CT-scans were performed: with and without ERB. A prostate planning target volume (PTV) was defined, and the Awall was delineated, using two different methods. Three-field and 4-field 3D-CRT plans, and IMRT plans were generated with a prescription dose of 78Gy. In 144 treatment plans, the minimum dose (D(min)), maximum dose (D(max)), and mean dose (D(mean)) to the Awall were calculated, as well as the Awall volumes exposed to doses ranging from >or=20Gy to >or=70Gy (V(20)-V(70), respectively). In the 3D-CRT plans, an ERB significantly reduced D(mean), D(max), and V(30)-V(70). For IMRT all investigated dose parameters were significantly reduced by the ERB. The absolute reduction of D(mean) was 12Gy in 3D-CRT and was 7.5Gy in IMRT for both methods of Awall delineation. Application of an ERB showed a significant Awall sparing effect in both 3D-CRT and IMRT. This may lead to reduced late anal toxicity in prostate radiotherapy.

  13. Pelvic Ewing sarcomas. Three-dimensional conformal vs. intensity-modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mounessi, F.S.; Lehrich, P.; Haverkamp, U.; Eich, H.T. [Muenster Univ. (Germany). Dept. of Radiation Oncology; Willich, N. [Muenster Univ. (Germany). Dept. of Radiation Oncology; Universitaetsklinikum Muenster (Germany). RiSK - Registry for the Evaluation of Late Side Effects after Radiotherapy in Childhood and Adolescence; Boelling, T. [Center for Radiation Oncology, Osnabrueck (Germany)

    2013-04-15

    The goal of the present work was to assess the potential advantage of intensity-modulated radiotherapy (IMRT) over three-dimensional conformal radiotherapy (3D-CRT) planning in pelvic Ewing's sarcoma. A total of 8 patients with Ewing sarcoma of the pelvis undergoing radiotherapy were analyzed. Plans for 3D-CRT and IMRT were calculated for each patient. Dose coverage of the planning target volume (PTV), conformity and homogeneity indices, as well as further parameters were evaluated. Results The average dose coverage values for PTV were comparable in 3D-CRT and IMRT plans. Both techniques had a PTV coverage of V{sub 95} > 98 % in all patients. Whereas the IMRT plans achieved a higher conformity index compared to the 3D-CRT plans (conformity index 0.79 {+-} 0.12 vs. 0.54 {+-} 0.19, p = 0.012), the dose distribution across the target volumes was less homogeneous with IMRT planning than with 3D-CRT planning. This difference was statistically significant (homogeneity index 0.11 {+-} 0.03 vs. 0.07 {+-} 0.0, p = 0.035). For the bowel, D{sub mean} and D{sub 1%}, as well as V{sub 2} to V{sub 60} were reduced in IMRT plans. For the bladder and the rectum, there was no significant difference in D{sub mean}. However, the percentages of volumes receiving at least doses of 30, 40, 45, and 50 Gy (V{sub 30} to V{sub 50}) were lower for the rectum in IMRT plans. The volume of normal tissue receiving at least 2 Gy (V{sub 2}) was significantly higher in IMRT plans compared with 3D-CRT, whereas at high dose levels (V{sub 30}) it was significantly lower. Compared to 3D-CRT, IMRT showed significantly better results regarding dose conformity (p = 0.012) and bowel sparing at dose levels above 30 Gy (p = 0.012). Thus, dose escalation in the radiotherapy of pelvic Ewing's sarcoma can be more easily achieved using IMRT. (orig.)

  14. Intensity modulated radiotherapy in early stage Hodgkin lymphoma patients: Is it better than three dimensional conformal radiotherapy?

    International Nuclear Information System (INIS)

    De Sanctis, Vitaliana; Chiacchiararelli, Laura; Enrici, Riccardo Maurizi; Bolzan, Chiara; D’Arienzo, Marco; Bracci, Stefano; Fanelli, Alessandro; Cox, Maria Christina; Valeriani, Maurizio; Osti, Mattia F; Minniti, Giuseppe

    2012-01-01

    Cure rate of early Hodgkin Lymphoma are high and avoidance of late toxicities is of paramount importance. This comparative study aims to assess the normal tissue sparing capability of intensity-modulated radiation therapy (IMRT) versus standard three-dimensional conformal radiotherapy (3D-CRT) in terms of dose-volume parameters and normal tissue complication probability (NTCP) for different organs at risk in supradiaphragmatic Hodgkin Lymphoma (HL) patients. Ten HL patients were actually treated with 3D-CRT and all treatments were then re-planned with IMRT. Dose-volume parameters for thyroid, oesophagus, heart, coronary arteries, lung, spinal cord and breast were evaluated. Dose-volume histograms generated by TPS were analyzed to predict the NTCP for the considered organs at risk, according to different endpoints. Regarding dose-volume parameters no statistically significant differences were recorded for heart and origin of coronary arteries. We recorded statistically significant lower V30 with IMRT for oesophagus (6.42 vs 0.33, p = 0.02) and lungs (4.7 vs 0.1 p = 0.014 for the left lung and 2.59 vs 0.1 p = 0.017 for the right lung) and lower V20 for spinal cord (17.8 vs 7.2 p = 0.02). Moreover the maximum dose to the spinal cord was lower with IMRT (30.2 vs 19.9, p <0.001). Higher V10 with IMRT for thyroid (64.8 vs 95, p = 0.0019) and V5 for lungs (30.3 vs 44.8, p = 0.03, for right lung and 28.9 vs 48.1, p = 0.001 for left lung) were found, respectively. Higher V5 and V10 for breasts were found with IMRT (V5: 4.14 vs 20.6, p = 0.018 for left breast and 3.3 vs 17, p = 0.059 for right breast; V10: 2.5 vs 13.6 p = 0.035 for left breast and 1.7 vs 11, p = 0.07 for the right breast.) As for the NTCP, our data point out that IMRT is not always likely to significantly increase the NTCP to OARs. In HL male patients IMRT seems feasible and accurate while for women HL patients IMRT should be used with caution

  15. Design and implementation of a system for treating paediatric patients with stereotactically-guided conformal radiotherapy

    International Nuclear Information System (INIS)

    Adams, Elizabeth J.; Suter, Bridget L.; Warrington, Alan P.; Black, Peter; Saran, Frank; Brada, Michael

    2001-01-01

    Background and purpose: Stereotactically-guided conformal radiotherapy (SCRT) allows the delivery of highly conformal dose distributions to localised brain tumours. This is of particular importance for children, whose often excellent long-term prognosis should be accompanied by low toxicity. The commercial immobilisation system in use at our hospital for adults was felt to be too heavy for children, and precluded the use of anaesthesia, which is sometimes required for paediatric patients. This paper therefore describes the design and implementation of a system for treating children with SCRT. This system needed to be well tolerated by patients, with good access for treating typical childhood malignancies. Materials and methods: A lightweight frame was developed for immobilisation, with a shell-based alternative for patients requiring general anaesthetic. Procedures were set up to introduce the patients to the frame system in order to maximise patient co-operation and comfort. Film measurements were made to assess the impact of the frame on transmission and surface dose. The reproducibility of the systems was assessed using electronic portal images. Results: Both frame and shell systems are in clinical use. The frame weighs 0.6 kg and is well tolerated. It has a transmission of 92-96%, and fields which pass through it deliver surface doses of 58-82% of the dose at d max , compared to 18% when no frame is present. However, the frame is constructed to maximise the availability of unobstructed beam directions. Reproducibility measurements for the frame showed a mean random error of 1.0±0.2 mm in two dimensions (2D) and 1.4±0.7 mm in 3D. The mean systematic error in 3D was 2.2 mm, and 90% of all overall 3D errors were less than 3.4 mm. For the shell system, the mean 2D random error was 1.5±0.2 mm. Conclusions: Two well-tolerated immobilisation devices have been developed for fractionated SCRT treatment of paediatric patients. A lightweight frame system gives a wide

  16. Design and implementation of a system for treating paediatric patients with stereotactically-guided conformal radiotherapy.

    Science.gov (United States)

    Adams, E J; Suter, B L; Warrington, A P; Black, P; Saran, F; Brada, M

    2001-09-01

    Stereotactically-guided conformal radiotherapy (SCRT) allows the delivery of highly conformal dose distributions to localised brain tumours. This is of particular importance for children, whose often excellent long-term prognosis should be accompanied by low toxicity. The commercial immobilisation system in use at our hospital for adults was felt to be too heavy for children, and precluded the use of anaesthesia, which is sometimes required for paediatric patients. This paper therefore describes the design and implementation of a system for treating children with SCRT. This system needed to be well tolerated by patients, with good access for treating typical childhood malignancies. A lightweight frame was developed for immobilisation, with a shell-based alternative for patients requiring general anaesthetic. Procedures were set up to introduce the patients to the frame system in order to maximise patient co-operation and comfort. Film measurements were made to assess the impact of the frame on transmission and surface dose. The reproducibility of the systems was assessed using electronic portal images. Both frame and shell systems are in clinical use. The frame weighs 0.6 kg and is well tolerated. It has a transmission of 92-96%, and fields which pass through it deliver surface doses of 58-82% of the dose at d(max), compared to 18% when no frame is present. However, the frame is constructed to maximise the availability of unobstructed beam directions. Reproducibility measurements for the frame showed a mean random error of 1.0+/-0.2mm in two dimensions (2D) and 1.4+/-0.7 mm in 3D. The mean systematic error in 3D was 2.2mm, and 90% of all overall 3D errors were less than 3.4mm. For the shell system, the mean 2D random error was 1.5+/-0.2mm. Two well-tolerated immobilisation devices have been developed for fractionated SCRT treatment of paediatric patients. A lightweight frame system gives a wide range of possible unobstructed beam directions, although beams that

  17. Health-Related Quality of Life in Patients With Locally Advanced Prostate Cancer After 76 Gy Intensity-Modulated Radiotherapy vs. 70 Gy Conformal Radiotherapy in a Prospective and Longitudinal Study

    International Nuclear Information System (INIS)

    Lips, Irene; Dehnad, Human; Kruger, Arto Boeken; Moorselaar, Jeroen van; Heide, Uulke van; Battermann, Jan; Vulpen, Marco van

    2007-01-01

    Purpose: To compare quality of life (QoL) after 70 Gy conformal radiotherapy with QoL after 76 Gy intensity-modulated radiotherapy (IMRT) in patients with locally advanced prostate carcinoma. Methods and Materials: Seventy-eight patients with locally advanced prostate cancer were treated with 70 Gy three-field conformal radiotherapy, and 92 patients received 76 Gy IMRT with fiducial markers for position verification. Quality of life was measured by RAND-36, the European Organization for Research and Treatment of Cancer core questionnaire (EORTC QLQ-C30(+3)), and the prostate-specific EORTC QLQ-PR25, before radiotherapy (baseline) and 1 month and 6 months after treatment. Quality of life changes in time (baseline vs. 1 month and baseline vs. 6 months) of ≥10 points were considered clinically relevant. Results: Differences between the treatment groups for QoL changes over time occurred in several QoL domains. The 76-Gy group revealed no significant deterioration in QoL compared with the 70-Gy group. The IMRT 76-Gy group even demonstrated a significantly better change in QoL from baseline to 1 month in several domains. The conformal 70-Gy group revealed temporary deterioration in pain, role functioning, and urinary symptoms; for the IMRT 76-Gy group a better QoL in terms of change in health existed after 1 month, which persisted after 6 months. For both treatment groups temporary deterioration in physical role restriction occurred after 1 month, and an improvement in emotional role restriction occurred after 6 months. Sexual activity was reduced after treatment for both groups and remained decreased after 6 months. Conclusions: Intensity-modulated radiotherapy and accurate position verification seem to provide a possibility to increase the radiation dose for prostate cancer without deterioration in QoL

  18. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor

    International Nuclear Information System (INIS)

    Shirato, Hiroki; Shimizu, Shinichi; Kitamura, Kei; Nishioka, Takeshi; Kagei, Kenji; Hashimoto, Seiko; Aoyama, Hidefumi; Kunieda, Tatsuya; Shinohara, Nobuo; Dosaka-Akita, Hirotoshi; Miyasaka, Kazuo

    2000-01-01

    Purpose: To achieve precise three-dimensional (3D) conformal radiotherapy for mobile tumors, a new radiotherapy system and its treatment planning system were developed and used for clinical practice. Methods and Materials: We developed a linear accelerator synchronized with a fluoroscopic real-time tumor tracking system by which 3D coordinates of a 2.0-mm gold marker in the tumor can be determined every 0.03 second. The 3D relationships between the marker and the tumor at different respiratory phases are evaluated using CT image at each respiratory phase, whereby the optimum phase can be selected to synchronize with irradiation (4D treatment planning). The linac is triggered to irradiate the tumor only when the marker is located within the region of the planned coordinates relative to the isocenter. Results: The coordinates of the marker were detected with an accuracy of ± 1 mm during radiotherapy in the phantom experiment. The time delay between recognition of the marker position and the start or stop of megavoltage X-ray irradiation was 0.03 second. Fourteen patients with various tumors were treated by conformal radiotherapy with a 'tight' planning target volume (PTV) margin. They were surviving without relapse or complications with a median follow-up of 6 months. Conclusion: Fluoroscopic real-time tumor tracking radiotherapy following 4D treatment planning was developed and shown to be feasible to improve the accuracy of the radiotherapy for mobile tumors

  19. Surgery and radiotherapy in the treatment of cutaneous melanoma

    DEFF Research Database (Denmark)

    Testori, A; Rutkowski, P; Marsden, J

    2009-01-01

    on individual circumstances. Radiotherapy is indicated as a treatment option in select patients with lentigo maligna melanoma and as an adjuvant in select patients with regional metastatic disease. Radiotherapy is also indicated for palliation, especially in bone and brain metastases....

  20. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Oh Nam [Gangneung Asan Hospital, Gangneung (Korea, Republic of); Yang, Oh Nam; Lim, Cheong Hwan [Hanseo Univ., Seosan (Korea, Republic of)

    2012-12-15

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

  1. Study on the photoneutrons produced in 15 MV medical linear accelerators : Comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Yang, Oh Nam; Yang, Oh Nam; Lim, Cheong Hwan

    2012-01-01

    Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photoneutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photon beams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the photoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose

  2. Dosimetric evaluation of tomography and four-box field conformal radiotherapy in locally advanced rectal cancer

    International Nuclear Information System (INIS)

    Yu, Mina; Lee, Hyo Chun; Chung, Mi Joo; Kim, Sung Hwan; Lee, Jong Hoon; Jang, Hong Seok; Jeon, Dong Min; Cheon, Geum Seong

    2013-01-01

    To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, Vn Gy, Dmin, Dmax, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p 0.001). But, V26.25 Gy and V27.5 Gywere not significantly different between the two modalities. Tomotherapy showed higher Dmax and lower Dmin. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

  3. Dosimetric evaluation of tomography and four-box field conformal radiotherapy in locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Mina; Lee, Hyo Chun; Chung, Mi Joo; Kim, Sung Hwan; Lee, Jong Hoon [Dept. of Radiation Oncology, St. Vincent' s Hospital, The Catholic University of Korea College of Medicine, Suwon (Korea, Republic of); Jang, Hong Seok; Jeon, Dong Min; Cheon, Geum Seong [Dept. of Radiation Oncology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2013-12-15

    To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, Vn Gy, Dmin, Dmax, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p 0.001). But, V26.25 Gy and V27.5 Gywere not significantly different between the two modalities. Tomotherapy showed higher Dmax and lower Dmin. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

  4. Comparing conformal, arc radiotherapy and helical tomotherapy in craniospinal irradiation planning.

    Science.gov (United States)

    Myers, Pamela A; Mavroidis, Panayiotis; Papanikolaou, Nikos; Stathakis, Sotirios

    2014-09-08

    Currently, radiotherapy treatment plan acceptance is based primarily on dosimetric performance measures. However, use of radiobiological analysis to assess benefit in terms of tumor control and harm in terms of injury to normal tissues can be advantageous. For pediatric craniospinal axis irradiation (CSI) patients, in particular, knowing the technique that will optimize the probabilities of benefit versus injury can lead to better long-term outcomes. Twenty-four CSI pediatric patients (median age 10) were retrospectively planned with three techniques: three-dimensional conformal radiation therapy (3D CRT), volumetric-modulated arc therapy (VMAT), and helical tomotherapy (HT). VMAT plans consisted of one superior and one inferior full arc, and tomotherapy plans were created using a 5.02cm field width and helical pitch of 0.287. Each plan was normalized to 95% of target volume (whole brain and spinal cord) receiving prescription dose 23.4Gy in 13 fractions. Using an in-house MATLAB code and DVH data from each plan, the three techniques were evaluated based on biologically effective uniform dose (D=), the complication-free tumor control probability (P+), and the width of the therapeutically beneficial range. Overall, 3D CRT and VMAT plans had similar values of D= (24.1 and 24.2 Gy), while HT had a D= slightly lower (23.6 Gy). The average values of the P+ index were 64.6, 67.4, and 56.6% for 3D CRT, VMAT, and HT plans, respectively, with the VMAT plans having a statistically significant increase in P+. Optimal values of D= were 28.4, 33.0, and 31.9 Gy for 3D CRT, VMAT, and HT plans, respectively. Although P+ values that correspond to the initial dose prescription were lower for HT, after optimizing the D= prescription level, the optimal P+ became 94.1, 99.5, and 99.6% for 3D CRT, VMAT, and HT, respectively, with the VMAT and HT plans having statistically significant increases in P+. If the optimal dose level is prescribed using a radiobiological evaluation method, as

  5. Hyperdosed radiotherapy in cancer treatment

    International Nuclear Information System (INIS)

    Machidon, Vasile; Jovmir, Vasile; Stanislav, Anastasia; Scurtu, Elena; Gazibar, Valeria; Lungu, Viorica

    2010-01-01

    The results of 328 patients with metastasizing breast cancer (BCM) are presented in the article. The distant metastases development in 4,5 % from the lot, which received the neoadjuvant treatment, is a high assurance in argumentation of preoperative hyperdosed X-ray therapy in breast cancer treatment. 15,8% from 100% - that is the significance of hyper dosed X-ray therapy versus classic X-ray therapy used preoperative in case of metastasizing breast cancer. The obtained data can not deny the efficacy of hyperdosed X-ray therapy in preoperative treatment of breast cancer. The hyperdosed X-ray therapy in the present moment remains current in the treatment of breast cancer and different localized cancers. (authors)

  6. Efficient CT simulation of the four-field technique for conformal radiotherapy of prostate carcinoma

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Waterman, Frank M.; Croce, Raymond J.; Corn, Benjamin; Suntharalingam, Nagalingam; Curran, Walter J.

    1997-01-01

    Purpose: Conformal radiotherapy of prostate carcinoma relies on contouring of individual CT slices for target and normal tissue localization. This process can be very time consuming. In the present report, we describe a method to more efficiently localize pelvic anatomy directly from digital reconstructed radiographs (DRRs). Materials and Methods: Ten patients with prostate carcinoma underwent CT simulation (the spiral mode at 3 mm separation) for conformal four-field 'box' radiotherapy. The bulbous urethra and bladder were opacified with iodinated contrast media. On lateral and anteroposterior DRRs, the volume of interest (VOI) was restricted to 1.0-1.5 cm tissue thickness to optimize digital radiograph reconstruction of the prostate and seminal vesicles. By removing unessential voxel elements, this method provided direct visualization of those structures. For comparison, the targets of each patient were also obtained by contouring CT axial slices. Results: The method was successfully performed if the target structures were readily visualized and geometrically corresponded to those generated by contouring axial images. The targets in 9 of 10 patients were reliable representations of the CT-contoured volumes. One patient had 18 mm variation due to the lack of bladder opacification. Using VOIs to generate thin tissue DRRs, the time required for target and normal tissue localization was on the average less than 5 min. Conclusion: In CT simulation of the four-field irradiation technique for prostate carcinoma, thin-tissue DRRs allowed for efficient and accurate target localization without requiring individual axial image contouring. This method may facilitate positioning of the beam isocenter and provide reliable conformal radiotherapy

  7. Conventional (2D) Versus Conformal (3D) Techniques in Radiotherapy for Malignant Pediatric Tumors: Dosimetric Perspectives

    International Nuclear Information System (INIS)

    Ahmad, N.; Attia, G.; Radwan, A.; El-Badawy, S.; El-Ghoneimy, E.

    2009-01-01

    Objectives: In pediatric radiotherapy, the enhanced radiosensitivity of the developing tissues combined with the high overall survival, raise the possibility of late complications. The present study aims at comparing two dimensional (2D) and three dimensional (3D) planning regarding dose homogeneity within target volume and dose to organs at risk (OARs) to demonstrate the efficacy of 3D in decreasing dose to normal tissue. Material and Methods: Thirty pediatric patients (18 years or less) with different pediatric tumors were planned using 2D and 3D plans. All were CT scanned after proper positioning and immobilization. Structures were contoured; including the planning target volume (PTV) and organs at risk (OARs). Conformal beams were designed and dose distribution analysis was edited to provide the best dose coverage to the PTV while sparing OARs using dose volume histograms (DVHs) of outlined structures. For the same PTVs conventional plans were created using the conventional simulator data (2-4 coplanar fields). Conventional and 3D plans coverage and distribution were compared using the term of V95% (volume of PTV receiving 95% of the prescribed dose), V107% (volume of PTV receiving 107% of the prescribed dose), and conformity index (CI) (volume receiving 90% of the prescribed dose/PTV). Doses received by OARs were compared in terms of mean dose. In children treated for brain lesions, OAR volume received 90% of the dose (V 90%) and OAR score were calculated. Results: The PTV coverage showed no statistical difference between 2D and 3D radiotherapy in terms of V95% or V107%. However, there was more conformity in 3D planning with CI 1.43 rather than conventional planning with CI 1.86 (p-value <0.001). Regarding OARs, 3D planning shows large gain in healthy tissue sparing. There was no statistical difference in mean dose received by each OAR. However, for brain cases, brain stem mean dose and brain V 90% showed better sparing in 3D planning (brain stem mean dose was

  8. Individualized margins in 3D conformal radiotherapy planning for lung cancer: analysis of physiological movements and their dosimetric impacts.

    Science.gov (United States)

    Germain, François; Beaulieu, Luc; Fortin, André

    2008-01-01

    In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generate individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage.

  9. Individualized Margins in 3D Conformal Radiotherapy Planning for Lung Cancer: Analysis of Physiological Movements and Their Dosimetric Impacts

    International Nuclear Information System (INIS)

    Germain, Francois; Beaulieu, Luc; Fortin, Andre

    2008-01-01

    In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generate individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage

  10. Conformal radiotherapy of locally advanced bile duct carcinoma; Radiotherapie conformationnelle des cholangiocarcinomes de la voie biliaire principale localement evolues

    Energy Technology Data Exchange (ETDEWEB)

    Bouras, N.; Caudry, M.; Bonnel, C.; Trouette, R.; Demeaux, H.; Maire, J.P. [Centre Hospitalier Universitaire, Hopital Saint-Andre, Service de Radiotherapie, 33 - Bordeaux (France); Saric, J.; Rullier, E. [Centre Hospitalier Universitaire, Hopital Saint-Andre, Service de Chirurgie Viscerale et de Transplantation Hepatique, 33 - Bordeaux (France)

    2002-02-01

    Purpose. - Retrospective study of 23 patients treated with conformal radiotherapy for a locally advanced bile duct carcinoma. Patients and methods. - Eight cases were irradiated after a radical resection (RO), because they were N+; seven after microscopically incomplete resection (R1) ; seven were not resected (R2). A dose of 45 of 50 Gy was delivered, followed by a boost up to 60 Gy in R1 and R2 groups. Concomitant chemotherapy was given in 15 cases. Results.-Late toxicity included a stenosis of the duodenum, and one of the biliary anastomosis. Two patients died from cholangitis, the mechanism of which remains unclear. Five patients are in complete remission, six had a local relapse, four developed a peritoneal carcinosis, and six distant metastases. Actuarial survival rate is 75%, 28% and 7% at 1, 3 and 5 years, respectively (median: 16.5 months). Seven patients are still alive with a 4 to 70 months follow-up. Survival is similar in the 3 small subgroups. The poor local control among RON+ cases might be related to the absence of a boost to the 'tumor bed'. In R1 patients, relapses were mainly distant metastases, where'as local and peritoneal recurrences predominated in R2. Conclusion. - Conformal radio-chemotherapy delivering 60 Gy represents a valuable palliative approach in locally advanced biliary carcinoma. (authors)

  11. Prevention and treatment of the orofacial complications of radiotherapy

    International Nuclear Information System (INIS)

    Rothwell, B.R.

    1987-01-01

    Radiotherapy of malignant head and neck tumors often causes extensive, permanent changes in salivary glands, peridental alveolar bone, and mucosal structures. Dental neglect and inappropriate dental management can cause complications. The potential orofacial side effects of radiotherapy are reviewed, as are preventive strategies for the dental treatment of patients scheduled to undergo radiotherapy

  12. A comparison of swallowing dysfunction after three-dimensional conformal and intensity-modulated radiotherapy. A systematic review by the Italian Head and Neck Radiotherapy Study Group

    International Nuclear Information System (INIS)

    Ursino, Stefano; Morganti, Riccardo; Cristaudo, Agostino; Paiar, Fabiola; D'Angelo, Elisa; Lohr, Frank; Mazzola, Rosario; Merlotti, Anna; Russi, Elvio Grazioso; Musio, Daniela; Alterio, Daniela; Bacigalupo, Almalina

    2017-01-01

    Dysphagia is one of the most important treatment-related side effects in head and neck cancer (HNC), as it can lead to severe life-threating complications such as aspiration pneumonia and malnutrition. Intensity-modulated radiotherapy (IMRT) could reduce swallowing dysfunction by producing a concave dose distribution and reducing doses to the swallowing-related organs at risk (SWOARs). The aim of this study was to review the current literature in order to compare swallowing outcomes between IMRT and three-dimensional conformal radiotherapy (3DCRT). A search was conducted in the PubMed and Embase databases to identify studies on swallowing outcomes, both clinically and/or instrumentally assessed, after 3DCRT and IMRT. Dysphagia-specific quality of life and objective instrumental data are summarized and discussed. A total of 262 papers were retrieved from the searched databases. An additional 23 papers were retrieved by hand-searching the reference lists. Ultimately, 22 papers were identified which discussed swallowing outcomes after 3DCRT and IMRT for HNC. No outcomes from randomized trials were identified. Despite several methodological limitations, reports from the current literature seem to suggest better swallowing outcomes with IMRT compared to 3DCRT. Further improvements are likely to result from the increased use of IMRT plans optimized for SWOAR sparing. (orig.) [de

  13. Radiotherapy

    International Nuclear Information System (INIS)

    Zedgenidze, G.A.; Kulikov, V.A.; Mardynskij, Yu.S.

    1984-01-01

    The technique for roentgenotopometric and medicamentous preparation of patients for radiotherapy has been reported in detail. The features of planning and performing of remote, intracavitary and combined therapy in urinary bladder cancer are considered. The more effective methods of radiotherapy have been proposed taking into account own experience as well as literature data. The comparative evaluation of treatment results and prognosis are given. Radiation pathomorphism of tumors and tissues of urinary bladder is considered in detail. The problems of diagnosis, prophylaxis and treatment of complications following radiodiagnosis and radiotherapy in patients with urinary bladder cancer are illustrated widely

  14. FDG-PET/CT Imaging for Staging and Target Volume Delineation in Preoperative Conformal Radiotherapy of Rectal Cancer

    International Nuclear Information System (INIS)

    Bassi, Maria Chiara; Turri, Lucia; Sacchetti, Gianmauro; Loi, Gianfranco; Cannillo, Barbara; La Mattina, Pierdaniele; Brambilla, Marco; Inglese, Eugenio; Krengli, Marco

    2008-01-01

    Purpose: To investigate the potential impact of using 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on staging and target volume delineation for patients affected by rectal cancer and candidates for preoperative conformal radiotherapy. Methods and Materials: Twenty-five patients diagnosed with rectal cancer T3-4 N0-1 M0-1 and candidates for preoperative radiotherapy underwent PET/CT simulation after injection of 5.18 MBq/kg of FDG. Clinical stage was reassessed on the basis of FDG-PET/CT findings. The gross tumor volume (GTV) and the clinical target volume (CTV) were delineated first on CT and then on PET/CT images. The PET/CT-GTV and PET/CT-CTV were analyzed and compared with CT-GTV and CT-CTV, respectively. Results: In 4 of 25 cases (24%), PET/CT affected tumor staging or the treatment purpose. In 3 of 25 cases (12%) staged N0 M0, PET/CT showed FDG uptake in regional lymph nodes and in a case also in the liver. In a patient with a single liver metastasis PET/CT detected multiple lesions, changing the treatment intent from curative to palliative. The PET/CT-GTV and PET/CT-CTV were significantly greater than the CT-GTV (p = 0.00013) and CT-CTV (p = 0.00002), respectively. The mean difference between PET/CT-GTV and CT-GTV was 25.4% and between PET/CT-CTV and CT-CTV was 4.1%. Conclusions: Imaging with PET/CT for preoperative radiotherapy of rectal cancer may lead to a change in staging and target volume delineation. Stage variation was observed in 12% of cases and a change of treatment intent in 4%. The GTV and CTV changed significantly, with a mean increase in size of 25% and 4%, respectively

  15. Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Fiorino, C.; Cattaneo, G.M.; Calandrino, R.; Reni, M.; Bolognesi, A.; Bonini, A.

    1998-01-01

    Background: Conformal radiotherapy requires reduced margins around the clinical target volume (CTV) with respect to traditional radiotherapy techniques. Therefore, high set-up accuracy and reproducibility are mandatory. Purpose: To investigate the effectiveness of two different immobilization techniques during conformal radiotherapy of prostate cancer with small fields. Materials and methods: 52 patients with prostate cancer were treated by conformal three- or four-field techniques with radical or adjuvant intent between November 1996 and March 1998. In total, 539 portal images were collected on a weekly basis for at least the first 4 weeks of the treatment on lateral and anterior 18 MV X-ray fields. The average number of sessions monitored per patient was 5.7 (range 4-10). All patients were immobilized with an alpha-cradle system; 25 of them were immobilized at the pelvis level (group A) and the remaining 27 patients were immobilized in the legs (group B). The shifts with respect to the simulation condition were assessed by measuring the distances between the same bony landmarks and the field edges. The global distributions of cranio-caudal (CC), posterior-anterior (PA) and left-right (LR) shifts were considered; for each patient random and systematic error components were assessed by following the procedure suggested by Bijhold et al. (Bijhold J, Lebesque JV, Hart AAM, Vijlbrief RE. Maximising set-up accuracy using portal images as applied to a conformal boost technique for prostatic cancer. Radiother. Oncol. 1992;24:261-271). For each patient the average isocentre (3D) shift was assessed as the quadratic sum of the average shifts in the three directions. Results 5 mm equal to 4.4% with respect to the 21.6% of group A (P<0.0001). This value was also better than the corresponding value found in a previously investigated group of 21 non-immobilized patients (Italia C, Fiorino C, Ciocca M, et al. Quality control by portal film analysis of the conformal radiotherapy

  16. Acute and Late Toxicity in a Randomized Trial of Conventional Versus Hypofractionated Three-Dimensional Conformal Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Arcangeli, Giorgio; Fowler, Jack; Gomellini, Sara; Arcangeli, Stefano; Saracino, Biancamaria; Petrongari, Maria Grazia; Benassi, Marcello; Strigari, Lidia

    2011-01-01

    Purpose: To compare the toxicity between hypofractionation vs. conventional fractionation schedules in patients with high-risk prostate cancer. Methods and Materials: Between January 2003 and December 2007, 168 patients were randomized to receive either hypofractionated (62 Gy in 20 fractions within 5 weeks, 4 fractions/wk) or conventionally fractionated (80 Gy in 40 fractions within 8 weeks) three-dimensional conformal radiotherapy to the prostate and seminal vesicles. All patients had undergone a 9-month course of total androgen deprivation, with radiotherapy starting 2 months after initiation of the total androgen deprivation. Results: The median follow-up was 32 and 35 months in the hypofractionation and conventional fractionation arms, respectively. For the patients developing acute toxicity, no difference between the two fractionation groups was found in either severity or duration of gastrointestinal or genitourinary toxicity. Also, no difference was found in the incidence and severity of late gastrointestinal and genitourinary toxicity between the two treatment schedules, with a 3-year rate of Grade 2 or greater toxicity of 17% and 16% for the hypofractionation arm and 14% and 11% for the conventional fractionation arm, respectively. A statistically significant correlation between acute and late gastrointestinal toxicity was found only in the conventional fractionation group. Conclusion: Our findings suggest that the hypofractionation regimen used in our study is safe, with only a slight, nonsignificant increase in tolerable and temporary acute toxicity compared with the conventional fractionation schedule. The severity and frequency of late complications was equivalent between the two treatment groups.

  17. Hyperfractionated conformal radiotherapy in locally advanced prostate cancer: results of a dose escalation study

    International Nuclear Information System (INIS)

    Forman, Jeffrey D.; Duclos, Marie; Shamsa, Falah; Porter, Arthur T.; Orton, Colin

    1996-01-01

    Purpose: This study was initiated to assess the incidence of chronic complications and histologic and biochemical control following hyperfractionated conformal radiotherapy in patients with locally advanced prostate cancer. Methods and Materials: Between October 1991 and October 1994, 49 patients with locally advanced prostate cancer were entered on the first two dose levels of a prospective dose-escalation study using hyperfractionated three dimensional conformal radiotherapy. The first 25 patients received a minimum tumor dose of 78 Gy to the prostate and seminal vesicles in 6 weeks at 1.3 Gy, b.i.d. No increase in chronic toxicity compared with conventional radiotherapy was noted; therefore, an additional 24 patients were treated to a minimum tumor dose of 82.8 Gy to the prostate and seminal vesicles in 7 weeks at 1.15 Gy, b.i.d. Toxicity was scored according to the Radiation Therapy Oncology Group morbidity grading scale. Efficacy was assessed through scheduled postradiation prostate specific antigen values and ultrasound-guided biopsies. The median follow-up for the entire group was 20 months. Results: The hyperfractionated external radiation was well tolerated with minimal acute morbidity. At 30 months, the actuarial probability of Grade 2 gastrointestinal toxicity was 17%. At 30 months, the actuarial probability of Grade 2 genitourinary toxicity was 16%. There was no statistically significant difference between the two dose levels. No Grade 3 or 4 gastrointestinal or genitourinary toxicity was noted. At 12 months, 84% of patients had a prostate specific antigen ≤ 4; and 53%; ≤ 1 ng/ml. At 12 months, 71% of patients had post radiation biopsies that were either negative (55%) or showed a marked therapeutic effect (16%). Conclusion: The use of hyperfractionated conformal radiotherapy facilitated dose escalation with no increase in chronic toxicity compared to standard doses. The initial tumor response based on prostate specific antigen measurements and

  18. Propensity Score-based Comparison of Long-term Outcomes With 3-Dimensional Conformal Radiotherapy vs Intensity-Modulated Radiotherapy for Esophageal Cancer

    International Nuclear Information System (INIS)

    Lin, Steven H.; Wang Lu; Myles, Bevan; Thall, Peter F.; Hofstetter, Wayne L.; Swisher, Stephen G.; Ajani, Jaffer A.; Cox, James D.; Komaki, Ritsuko; Liao Zhongxing

    2012-01-01

    Purpose: Although 3-dimensional conformal radiotherapy (3D-CRT) is the worldwide standard for the treatment of esophageal cancer, intensity modulated radiotherapy (IMRT) improves dose conformality and reduces the radiation exposure to normal tissues. We hypothesized that the dosimetric advantages of IMRT should translate to substantive benefits in clinical outcomes compared with 3D-CRT. Methods and Materials: An analysis was performed of 676 nonrandomized patients (3D-CRT, n=413; IMRT, n=263) with stage Ib-IVa (American Joint Committee on Cancer 2002) esophageal cancers treated with chemoradiotherapy at a single institution from 1998-2008. An inverse probability of treatment weighting and inclusion of propensity score (treatment probability) as a covariate were used to compare overall survival time, interval to local failure, and interval to distant metastasis, while accounting for the effects of other clinically relevant covariates. The propensity scores were estimated using logistic regression analysis. Results: A fitted multivariate inverse probability weighted-adjusted Cox model showed that the overall survival time was significantly associated with several well-known prognostic factors, along with the treatment modality (IMRT vs 3D-CRT, hazard ratio 0.72, P<.001). Compared with IMRT, 3D-CRT patients had a significantly greater risk of dying (72.6% vs 52.9%, inverse probability of treatment weighting, log-rank test, P<.0001) and of locoregional recurrence (P=.0038). No difference was seen in cancer-specific mortality (Gray's test, P=.86) or distant metastasis (P=.99) between the 2 groups. An increased cumulative incidence of cardiac death was seen in the 3D-CRT group (P=.049), but most deaths were undocumented (5-year estimate, 11.7% in 3D-CRT vs 5.4% in IMRT group, Gray's test, P=.0029). Conclusions: Overall survival, locoregional control, and noncancer-related death were significantly better after IMRT than after 3D-CRT. Although these results need

  19. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit

    OpenAIRE

    Rutonjski Laza; Petrović Borislava; Baucal Milutin; Teodorović Milan; Čudić Ozren; Gershkevitsh Eduard; Izewska Joanna

    2012-01-01

    Abstract Background Independent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes. Methods The audit was conducte...

  20. Questionnaire based quality assurance for the RT01 trial of dose escalation in conformal radiotherapy for prostate cancer (ISRCTN 47772397)

    International Nuclear Information System (INIS)

    Mayles, W.; Moore, A.Rollo; Aird, Edwin G.A.; Bidmead, A. Margaret; Dearnaley, David P.; Griffiths, Sue E.; Stephens, Richard J.; Warrington, A.P. Jim

    2004-01-01

    Background and purpose: In order to ensure the validity of the outcome of the Medical Research Council's 'RT01 trial' of dose escalation in conformal radiotherapy for prostate cancer it was considered important that the quality of treatment delivery should meet an adequate standard across all contributing centres. A questionnaire was therefore devised to ensure that all aspects of the planning and delivery process were adequately covered. Patients and methods: The questionnaire considered each step in the planning and delivery process and drew the attention of the participants to the specific requirements of the trial. Before entering patients into the trial each participating centre had to complete the questionnaire and an outlining exercise (reported elsewhere). Results: It was not practicable to define a detailed universally acceptable protocol for the whole process of delivery of conformal radiotherapy, not least because of the different equipment available for planning and treatment in different centres. The questionnaire identified some areas of difference in practice between centres where there may be a need for the development of a consensus as to best practice, particularly in the area of patient set-up. Occasionally it was necessary to follow up responses to questions that had been misunderstood or inadequately answered, but in most cases these issues proved to be easily resolved. Conclusions: The questionnaire proved to be a useful self-assessment tool as well as enabling the quality assurance group to ensure that the standards of the trial were being met. Subsequent follow-up visits confirmed the usefulness and validity of this self assessment process

  1. Integral Dose and Radiation-Induced Secondary Malignancies: Comparison between Stereotactic Body Radiation Therapy and Three-Dimensional Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Stefano G. Masciullo

    2012-11-01

    Full Text Available The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID in stereotactic body radiation therapy (SBRT with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT, estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage and applying a dose scheme of 2 Gy × 32 fractions. The dose equivalence between the different treatment modalities was achieved assuming α/β = 10Gy for tumor tissue and imposing the same biological effective dose (BED on the target (BED = 76Gy10. Total NTIDs for both techniques was calculated considering α/β = 3Gy for healthy tissue. Excess absolute cancer risk (EAR was calculated for various organs using a mechanistic model that includes fractionation effects. A paired two-tailed Student t-test was performed to determine statistically significant differences between the data (p ≤ 0.05. Our study indicates that despite the fact that for all patients integral dose is higher for SBRT treatments than 3D-CRT (p = 0.002, secondary cancer risk associated to SBRT patients is significantly smaller than that calculated for 3D-CRT (p = 0.001. This suggests that integral dose is not a good estimator for quantifying cancer induction. Indeed, for the model and parameters used, hypofractionated radiotherapy has the potential for secondary cancer reduction. The development of reliable secondary cancer risk models seems to be a key issue in fractionated radiotherapy. Further assessments of integral doses received with 3D-CRT and other special techniques are also strongly encouraged.

  2. Late rectal toxicity: dose-volume effects of conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Huang, Eugene H.; Pollack, Alan; Levy, Larry; Starkschall, George; Lei Dong; Rosen, Isaac; Kuban, Deborah A.

    2002-01-01

    Purpose: To identify dosimetric, anatomic, and clinical factors that correlate with late rectal toxicity after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: We retrospectively analyzed the dose-volume histograms and clinical records of 163 Stage T1b-T3c prostate cancer patients treated between 1992 and 1999 with 3D-CRT, to a total isocenter dose of 74-78 Gy at The University of Texas M. D. Anderson Cancer Center. The median follow-up was 62 months (range 24-102). All late rectal complications were scored using modified Radiation Therapy Oncology Group and Late Effects Normal Tissue Task Force criteria. The 6-year toxicity rate was assessed using Kaplan-Meier analysis and the log-rank test. A univariate proportional hazards regression model was used to test the correlation between Grade 2 or higher toxicity and the dosimetric, anatomic, and clinical factors. In a multivariate regression model, clinical factors were added to the dosimetric and anatomic variables to determine whether they significantly altered the risk of developing late toxicity. Results: At 6 years, the rate of developing Grade 2 or higher late rectal toxicity was 25%. A significant volume effect was observed at rectal doses of 60, 70, 75.6, and 78 Gy, and the risk of developing rectal complications increased exponentially as greater volumes were irradiated. Although the percentage of rectal volume treated correlated significantly with the incidence of rectal complications at all dose levels (p 3 of the rectum. Of the clinical variables tested, only a history of hemorrhoids correlated with rectal toxicity (p=0.003). Multivariate analysis showed that the addition of hemorrhoids increased the risk of toxicity for each dosimetric variable found to be significant on univariate analysis (p<0.05 for all comparisons). Conclusion: Dose-volume histogram analyses clearly indicated a volume effect on the probability of developing late rectal complications

  3. Clinical results of conformal versus intensity-modulated radiotherapy using a focal simultaneous boost for muscle-invasive bladder cancer in elderly or medically unfit patients.

    Science.gov (United States)

    Lutkenhaus, Lotte J; van Os, Rob M; Bel, Arjan; Hulshof, Maarten C C M

    2016-03-18

    For elderly or medically unfit patients with muscle-invasive bladder cancer, cystectomy or chemotherapy are contraindicated. This leaves radical radiotherapy as the only treatment option. It was the aim of this study to retrospectively analyze the treatment outcome and associated toxicity of conformal versus intensity-modulated radiotherapy (IMRT) using a focal simultaneous tumor boost for muscle-invasive bladder cancer in patients not suitable for cystectomy. One hundred eighteen patients with T2-4 N0-1 M0 bladder cancer were analyzed retrospectively. Median age was 80 years. Treatment consisted of either a conformal box technique or IMRT and included a simultaneous boost to the tumor. To enable an accurate boost delivery, fiducial markers were placed around the tumor. Patients were treated with 40 Gy in 20 fractions to the elective treatment volumes, and a daily tumor boost up to 55-60 Gy. Clinical complete response was seen in 87 % of patients. Three-year overall survival was 44 %, with a locoregional control rate of 73 % at 3 years. Toxicity was low, with late urinary and intestinal toxicity rates grade ≥ 2 of 14 and 5 %, respectively. The use of IMRT reduced late intestinal toxicity, whereas fiducial markers reduced acute urinary toxicity. Radical radiotherapy using a focal boost is feasible and effective for elderly or unfit patients, with a 3-year locoregional control of 73 %. Toxicity rates were low, and were reduced by the use of IMRT and fiducial markers.

  4. Emerging paradigm in radiobiology in concept and practices of hypo fractionated conformal radiotherapy

    International Nuclear Information System (INIS)

    Mishra, S.P.; Srivastava, Anoop Kumar; Rastogi, Madhup; Khurana, Rohini; Pawaskar, Asawari

    2016-01-01

    This study has been performed in clinical setting by creating the treatment plan in dynamic conformal arc mode as the treatment delivery technique; with add on collimator APEX system having 56 pairs of 2.5 mm each as treatment unit. Photon beam energy selected for the study was 6 MV. Various number of treatment arcs were applied depending upon the location of the PTV. The PTV was prescribed a total dose of 60 Gy in five fractions

  5. Telemedicine in radiotherapy treatment planning: requirements and applications

    International Nuclear Information System (INIS)

    Olsen, D.R.; Bruland, O.S.; Davis, B.J.

    2000-01-01

    Telemedicine facilitates decentralized radiotherapy services by allowing remote treatment planning and quality assurance of treatment delivery. A prerequisite is digital storage of relevant data and an efficient and reliable telecommunication system between satellite units and the main radiotherapy clinic. The requirements of a telemedicine system in radiotherapy is influenced by the level of support needed. In this paper we differentiate between three categories of telemedicine support in radiotherapy. Level 1 features video conferencing and display of radiotherapy images and dose plans. Level 2 involves replication of selected data from the radiotherapy database - facilitating remote treatment planning and evaluation. Level 3 includes real-time, remote operations, e.g. target volume delineation and treatment planning performed by the team at the satellite unit under supervision and guidance from more experienced colleagues at the main clinic. (author)

  6. Treatment planning systems for high precision radiotherapy

    International Nuclear Information System (INIS)

    Deshpande, D.D.

    2008-01-01

    Computerized Treatment Planning System (TPS) play an important role in radiotherapy with the intent to maximize tumor control and minimize normal tissue complications. Treatment planning during earlier days was generally carried out through the manual summations of standard isodose charts on to patient body contours that were generated by direct tracing or lead wire representation, and relied heavily on the careful choices of beam weights and wedging. Since then there had been tremendous advances in field of Radiation Oncology in last few decades. The linear accelerators had evolved from MLC's to IGRT, the techniques like 3DCRT, IMRT has become almost routine affair. The simulation has seen transition from simple 2D film/fluoroscopy localization to CT Simulator with added development in PET, PET- CT and MR imaging. The Networking and advances in computer technology has made it possible to direct transfer of Images, contours to the treatment planning systems

  7. Improvement in toxicity in high risk prostate cancer patients treated with image-guided intensity-modulated radiotherapy compared to 3D conformal radiotherapy without daily image guidance

    International Nuclear Information System (INIS)

    Sveistrup, Joen; Rosenschöld, Per Munck af; Deasy, Joseph O; Oh, Jung Hun; Pommer, Tobias; Petersen, Peter Meidahl; Engelholm, Svend Aage

    2014-01-01

    Image-guided radiotherapy (IGRT) facilitates the delivery of a very precise radiation dose. In this study we compare the toxicity and biochemical progression-free survival between patients treated with daily image-guided intensity-modulated radiotherapy (IG-IMRT) and 3D conformal radiotherapy (3DCRT) without daily image guidance for high risk prostate cancer (PCa). A total of 503 high risk PCa patients treated with radiotherapy (RT) and endocrine treatment between 2000 and 2010 were retrospectively reviewed. 115 patients were treated with 3DCRT, and 388 patients were treated with IG-IMRT. 3DCRT patients were treated to 76 Gy and without daily image guidance and with 1–2 cm PTV margins. IG-IMRT patients were treated to 78 Gy based on daily image guidance of fiducial markers, and the PTV margins were 5–7 mm. Furthermore, the dose-volume constraints to both the rectum and bladder were changed with the introduction of IG-IMRT. The 2-year actuarial likelihood of developing grade > = 2 GI toxicity following RT was 57.3% in 3DCRT patients and 5.8% in IG-IMRT patients (p < 0.001). For GU toxicity the numbers were 41.8% and 29.7%, respectively (p = 0.011). On multivariate analysis, 3DCRT was associated with a significantly increased risk of developing grade > = 2 GI toxicity compared to IG-IMRT (p < 0.001, HR = 11.59 [CI: 6.67-20.14]). 3DCRT was also associated with an increased risk of developing GU toxicity compared to IG-IMRT. The 3-year actuarial biochemical progression-free survival probability was 86.0% for 3DCRT and 90.3% for IG-IMRT (p = 0.386). On multivariate analysis there was no difference in biochemical progression-free survival between 3DCRT and IG-IMRT. The difference in toxicity can be attributed to the combination of the IMRT technique with reduced dose to organs-at-risk, daily image guidance and margin reduction

  8. Concurrent paclitaxel and radiotherapy. Treatment feasibility studies

    International Nuclear Information System (INIS)

    Vogt, H.G.; Martin, T.; Kolotas, C.; Hey, S.; Schneider, L.; Templin, T.; Zamboglou, N.; Dornoff, W.; Kettner, H.

    1997-01-01

    with 5x18 Gy/week up to 59.4 to 73.8 Gy. - VII. Concurrent paclitaxel and radiation for gliomas of the brain: 100 mg/m 2 paclitaxel as a 3-hour infusion weekly for 6 weeks simultaneous with radiotherapy in shrinking field technique with 5x2 Gy/week up to 60 Gy. Results: Our initial experiences with weekly application of paclitaxel as a 3-hour infusion in the dosages we used for simultaneous radiochemotherapy of malignancies in different anatomical sites has shown that this treatment concept is feasible, safe and effective. Conclusions: Whether this combined modality will enhance the response rates or influence survival rates has yet to be confirmed in phase-III studies. (orig.) [de

  9. Geometrical uncertainty margins in 3D conformal radiotherapy in the pediatric age group

    International Nuclear Information System (INIS)

    Eldebawy, E.; Attalla, E.; Eldesoky, I.; Zaghloul, M.S.

    2011-01-01

    To evaluate set-up variation of pediatric patients undergoing 3D conformal radiotherapy (3DCRT) using electronic portal image device (EPID), in an effort to evaluate the adequacy of the planning target volume (PTV) margin employed for the 3DCRT treatment of pediatric patients. Materials and methods: Set-up data was collected from 48 pediatric patients treated with 3D CRT-for head and neck (31 patients), abdomino-pelvic (9 patients) and chest (8 patients) sites during the period between September 2008 and February 2009. A total of 358 images obtained by EPID were analyzed. The mean (M) and standard deviation (SD) for systematic and random errors were calculated and the results were analyzed. Results: All images were studied in anterior and lateral portals. The systematic errors along longitudinal, lateral and vertical directions in all patients showed an M equal to 1.9,1.6, and 1.6 mm with SD of 1.8,1.4, and 1.8 mm, respectively; (head and neck cases: M equal to 1.5,1.2, and 1.6 mm with SD 1.4,1.2, and 1.8 mm; chest cases: M equal to 2.5,1.8, and 0.8 mm with SD 2.7,1.7, and 1.2 mm, abdomen-pelvic cases: M equal to 2.9,2.8 and 2.3 mm with SD 1.6,1.2, and 2.3 mm). Similarly, the random errors for all patients showed SD of 1.9,1.6, and 1.8 mm, respectively (head and neck cases: SD 1.7,1.3, and 1.5 mm; chest cases: SD 1.2,1.9, and 2.5 mm; abdomino-pelvic cases SD 2.5, 2, and 2.4 mm, respectively). Using Van Herk's formula the suggested (PTV) margin around the clinical target volume (CTV) of 5.5 mm appears to be adequate. Conclusion: The ranges of set-up errors are site specific and depends on many factors

  10. A Retrospective Comparison of Robotic Stereotactic Body Radiotherapy and Three-Dimensional Conformal Radiotherapy for the Reirradiation of Locally Recurrent Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Ozyigit, Gokhan; Cengiz, Mustafa; Yazici, Gozde; Yildiz, Ferah; Gurkaynak, Murat; Zorlu, Faruk; Yildiz, Demet; Hosal, Sefik; Gullu, Ibrahim; Akyol, Fadil

    2011-01-01

    Purpose: We assessed therapeutic outcomes of reirradiation with robotic stereotactic radiotherapy (SBRT) for locally recurrent nasopharyngeal carcinoma (LRNPC) patients and compared those results with three-dimensional conformal radiotherapy (CRT) with or without brachytherapy (BRT). Methods and Materials: Treatment outcomes were evaluated retrospectively in 51 LRNPC patients receiving either robotic SBRT (24 patients) or CRT with or without BRT (27 patients) in our department. CRT was delivered with a 6-MV linear accelerator, and a median total reirradiation dose of 57 Gy in 2 Gy/day was given. Robotic SBRT was delivered with CyberKnife (Accuray, Sunnyvale, CA). Patients in the SBRT arm received 30 Gy over 5 consecutive days. We calculated actuarial local control and cancer-specific survival rates for the comparison of treatment outcomes in SBRT and CRT arms. The Common Terminology Criteria for Adverse Events v3.0 was used for toxicity evaluation. Results: The median follow-up was 24 months for all patients. Two-year actuarial local control rates were 82% and 80% for SBRT and CRT arms, respectively (p = 0.6). Two-year cancer-specific survival rates were 64% and 47% for the SBRT and CRT arms, respectively (p = 0.4). Serious late toxicities (Grade 3 and above) were observed in 21% of patients in the SBRT arm, whereas 48% of patients had serious toxicity in the CRT arm (p = 0.04). Fatal complications occurred in three patients (12.5%) of the SBRT arm, and four patients (14.8%) of the CRT arm (p = 0.8). T stage at recurrence was the only independent predictor for local control and survival. Conclusion: Our robotic SBRT protocol seems to be feasible and less toxic in terms of late effects compared with CRT arm for the reirradiation of LRNPC patients.

  11. Practical application of the tool calculation Monte Carlo MCVerif for checking for radiotherapy treatment

    International Nuclear Information System (INIS)

    Laliena Bielsa, V. M.; Garcia Romero, A.; Villa Gazulla, D.; Ortega Pardilla, P.; Calvo Carrillo, S.; Millan Cebrian, E.; Hernandez Vitorial, A.; Canellas Aznoz, M.

    2013-01-01

    The object of this work is to verify a patient group representative of the usual techniques of 3D conformal radiotherapy and IMRT performed in the radiotherapy service our hospital and thus validate the algorithm used commercial planning system. (Author)

  12. Dosimetry audit of radiotherapy treatment planning systems

    International Nuclear Information System (INIS)

    Bulski, Wojciech; Chelminski, Krzysztof; Rostkowska, Joanna

    2015-01-01

    In radiotherapy Treatment Planning Systems (TPS) various calculation algorithms are used. The accuracy of dose calculations has to be verified. Numerous phantom types, detectors and measurement methodologies are proposed to verify the TPS calculations with dosimetric measurements. A heterogeneous slab phantom has been designed within a Coordinated Research Project (CRP) of the IAEA. The heterogeneous phantom was developed in the frame of the IAEA CRP. The phantom consists of frame slabs made with polystyrene and exchangeable inhomogeneity slabs equivalent to bone or lung tissue. Special inserts allow to position thermoluminescent dosimeters (TLD) capsules within the polystyrene slabs below the bone or lung equivalent slabs and also within the lung equivalent material. Additionally, there are inserts that allow to position films or ionisation chamber in the phantom. Ten Polish radiotherapy centres (of 30 in total) were audited during on-site visits. Six different TPSs and five calculation algorithms were examined in the presence of inhomogeneities. Generally, most of the results from TLD were within 5 % tolerance. Differences between doses calculated by TPSs and measured with TLD did not exceed 4 % for bone and polystyrene equivalent materials. Under the lung equivalent material, on the beam axis the differences were lower than 5 %, whereas inside the lung equivalent material, off the beam axis, in some cases they were of around 7 %. The TLD results were confirmed with the ionisation chamber measurements. The comparison results of the calculations and the measurements allow to detect limitations of TPS calculation algorithms. The audits performed with the use of heterogeneous phantom and TLD seem to be an effective tool for detecting the limitations in the TPS performance or beam configuration errors at audited radiotherapy departments. (authors)

  13. Dosimetry audit of radiotherapy treatment planning systems.

    Science.gov (United States)

    Bulski, Wojciech; Chełmiński, Krzysztof; Rostkowska, Joanna

    2015-07-01

    In radiotherapy Treatment Planning Systems (TPS) various calculation algorithms are used. The accuracy of dose calculations has to be verified. Numerous phantom types, detectors and measurement methodologies are proposed to verify the TPS calculations with dosimetric measurements. A heterogeneous slab phantom has been designed within a Coordinated Research Project (CRP) of the IAEA. The heterogeneous phantom was developed in the frame of the IAEA CRP. The phantom consists of frame slabs made with polystyrene and exchangeable inhomogeneity slabs equivalent to bone or lung tissue. Special inserts allow to position thermoluminescent dosimeters (TLD) capsules within the polystyrene slabs below the bone or lung equivalent slabs and also within the lung equivalent material. Additionally, there are inserts that allow to position films or ionisation chamber in the phantom. Ten Polish radiotherapy centres (of 30 in total) were audited during on-site visits. Six different TPSs and five calculation algorithms were examined in the presence of inhomogeneities. Generally, most of the results from TLD were within 5 % tolerance. Differences between doses calculated by TPSs and measured with TLD did not exceed 4 % for bone and polystyrene equivalent materials. Under the lung equivalent material, on the beam axis the differences were lower than 5 %, whereas inside the lung equivalent material, off the beam axis, in some cases they were of around 7 %. The TLD results were confirmed with the ionisation chamber measurements. The comparison results of the calculations and the measurements allow to detect limitations of TPS calculation algorithms. The audits performed with the use of heterogeneous phantom and TLD seem to be an effective tool for detecting the limitations in the TPS performance or beam configuration errors at audited radiotherapy departments. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Dosimetric comparison of different treatment modalities for stereotactic radiotherapy.

    Science.gov (United States)

    Hsu, Shih-Ming; Lai, Yuan-Chun; Jeng, Chien-Chung; Tseng, Chia-Ying

    2017-09-16

    The modalities for performing stereotactic radiotherapy (SRT) on the brain include the cone-based linear accelerator (linac), the flattening filter-free (FFF) volumetric modulated arc therapy (VMAT) linac, and tomotherapy. In this study, the cone-based linac, FFF-VMAT linac, and tomotherapy modalities were evaluated by measuring the differences in doses delivered during brain SRT and experimentally assessing the accuracy of the output radiation doses through clinical measurements. We employed a homemade acrylic dosimetry phantom representing the head, within which a thermoluminescent dosimeter (TLD) and radiochromic EBT3 film were installed. Using the conformity/gradient index (CGI) and Paddick methods, the quality of the doses delivered by the various SRT modalities was evaluated. The quality indicators included the uniformity, conformity, and gradient indices. TLDs and EBT3 films were used to experimentally assess the accuracy of the SRT dose output. The dose homogeneity indices of all the treatment modalities were lower than 1.25. The cone-based linac had the best conformity for all tumors, regardless of the tumor location and size, followed by the FFF-VMAT linac; tomography was the worst-performing treatment modality in this regard. The cone-based linac had the best gradient, regardless of the tumor location and size, whereas the FFF-VMAT linac had a better gradient than tomotherapy for a large tumor diameter (28 mm). The TLD and EBT3 measurements of the dose at the center of tumors indicated that the average difference between the measurements and the calculated dose was generally less than 4%. When the 3% 3-mm gamma passing rate metric was used, the average passing rates of all three treatment modalities exceeded 98%. Regarding the dose, the cone-based linac had the best conformity and steepest dose gradient for tumors of different sizes and distances from the brainstem. The results of this study suggest that SRT should be performed using the cone

  15. A pilot survey of sexual function and quality of life following 3D conformal radiotherapy for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Roach, Mack; Chinn, Daniel M.; Holland, John; Clarke, Michelle

    1996-01-01

    Purpose: To assess the impact of high dose three-dimensional conformal radiotherapy (3D CRT) for prostate cancer on the sexual function-related quality of life of patients and their partners. Methods and Materials: Sixty of 124 consecutive patients (median age 72.3 years) treated with 3D CRT for localized prostate cancer were surveyed and reported being potent prior to treatment. The answers to survey questions assessing the impact of quality of life related to sexual function from these 60 patients and their partners forms the basis for this retrospective analysis. Results: Following 3D CRT, 37 of 60 patients (62%) retained sexual function sufficient for intercourse. Intercourse at least once per month was reduced from 71 to 40%, whereas intercourse less than once per year increased from 12 to 35%. Following treatment, 25% of patients reported that the change in sexual dysfunction negatively affected their relationship or resulted in poor self-esteem. This outcome was associated with impotence following treatment (p < 0.01). Patients who had partners and satisfactory sexual function appeared to be at a higher risk of having a negatively affected relationship or losing self-esteem if they become impotent (p < 0.05). Partners of patients who reported a negatively affected relationship or loss of self-esteem appear to be less likely to return the survey instrument used (p = 0.02). Conclusions: More work is needed to evaluate the impact of radiotherapy and other treatments on the quality of life of patients and their partners to allow adequate informed consent to be given

  16. Intensity-modulated conformal radiotherapy in the anal canal cancer. Report of technological assessment. Updating of the 2006 report

    International Nuclear Information System (INIS)

    2015-07-01

    As intensity-modulated conformal radiotherapy (IMCR) has already been technologically assessed in 2006 with a positive opinion for some treatments and a negative one for others, and as this technique displays some interesting properties for the treatment of pelvic cancers (optimisation of dose distribution, preservation of sane tissues, reduction of secondary effects during irradiation), this report proposes an assessment of clinical safety and efficiency of IMCR in the treatment of an anal canal cancer. After a discussion of generalities, of histological and epidemiological data, and of knowledge regarding treatment and follow-up of this cancer, the report presents the IMCR technique, some regulatory aspects, and its applications to the considered cancer. The methodology adopted for this assessment is then presented. Based on various studies and clinical results, the IMCR clinical safety and efficiency in the treatment of the anal canal cancer are discussed and assessed. Recommendations produced by different medical professional bodies are reported. Opinion of experts and a synthesis of stakeholders are then proposed

  17. Minimising contralateral breast dose in post-mastectomy intensity-modulated radiotherapy by incorporating conformal electron irradiation

    NARCIS (Netherlands)

    van der Laan, Hans Paul; Korevaar, Erik W; Dolsma, Willemtje; Maduro, John H; Langendijk, Johannes A

    PURPOSE: To assess the potential benefit of incorporating conformal electron irradiation in intensity-modulated radiotherapy (IMRT) for loco-regional post-mastectomy RT. PATIENTS AND METHODS: Ten consecutive patients that underwent left-sided mastectomy were selected for this comparative planning

  18. Dosimetric comparison of intensity-modulated, conformal, and four-field pelvic radiotherapy boost plans for gynecologic cancer: a retrospective planning study

    International Nuclear Information System (INIS)

    Chan, Philip; Yeo, Inhwan; Perkins, Gregory; Fyles, Anthony; Milosevic, Michael

    2006-01-01

    To evaluate intensity-modulated radiation therapy (IMRT) as an alternative to conformal radiotherapy (CRT) or 4-field box boost (4FB) in women with gynecologic malignancies who are unsuitable for brachytherapy for technical or medical reasons. Dosimetric and toxicity information was analyzed for 12 patients with cervical (8), endometrial (2) or vaginal (2) cancer previously treated with external beam pelvic radiotherapy and a CRT boost. Optimized IMRT boost treatment plans were then developed for each of the 12 patients and compared to CRT and 4FB plans. The plans were compared in terms of dose conformality and critical normal tissue avoidance. The median planning target volume (PTV) was 151 cm 3 (range 58–512 cm 3 ). The median overlap of the contoured rectum with the PTV was 15 (1–56) %, and 11 (4–35) % for the bladder. Two of the 12 patients, both with large PTVs and large overlap of the contoured rectum and PTV, developed grade 3 rectal bleeding. The dose conformity was significantly improved with IMRT over CRT and 4FB (p ≤ 0.001 for both). IMRT also yielded an overall improvement in the rectal and bladder dose-volume distributions relative to CRT and 4FB. The volume of rectum that received the highest doses (>66% of the prescription) was reduced by 22% (p < 0.001) with IMRT relative to 4FB, and the bladder volume was reduced by 19% (p < 0.001). This was at the expense of an increase in the volume of these organs receiving doses in the lowest range (<33%). These results indicate that IMRT can improve target coverage and reduce dose to critical structures in gynecologic patients receiving an external beam radiotherapy boost. This dosimetric advantage will be integrated with other patient and treatment-specific factors, particularly internal tumor movement during fractionated radiotherapy, in the context of a future image-guided radiation therapy study

  19. A FAST MORPHING-BASED INTERPOLATION FOR MEDICAL IMAGES: APPLICATION TO CONFORMAL RADIOTHERAPY

    Directory of Open Access Journals (Sweden)

    Hussein Atoui

    2011-05-01

    Full Text Available A method is presented for fast interpolation between medical images. The method is intended for both slice and projective interpolation. It allows offline interpolation between neighboring slices in tomographic data. Spatial correspondence between adjacent images is established using a block matching algorithm. Interpolation of image intensities is then carried out by morphing between the images. The morphing-based method is compared to standard linear interpolation, block-matching-based interpolation and registrationbased interpolation in 3D tomographic data sets. Results show that the proposed method scored similar performance in comparison to registration-based interpolation, and significantly outperforms both linear and block-matching-based interpolation. This method is applied in the context of conformal radiotherapy for online projective interpolation between Digitally Reconstructed Radiographs (DRRs.

  20. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    International Nuclear Information System (INIS)

    Cavinato, Christianne C.; Campos, Leticia L.; Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B.; Giordani, Adelmo J.

    2011-01-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  1. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Cavinato, Christianne C.; Campos, Leticia L., E-mail: ccavinato@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B., E-mail: bhsouza@unifesp.b, E-mail: daros.kellen@unifesp.b, E-mail: rbitel-li.ddi@epm.b [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagem; Giordani, Adelmo J. [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Servico de Radioterapia

    2011-07-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  2. Simulation and radiation treatment in external radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Singer, E [Mevaterapia Medical Center, Buenos Aires (Argentina)

    1996-08-01

    It is well known that in order to obtain a uniform dose in the treated volume as defined in ICRU 50, there should be a 10% maximum difference between maximum and minimum dose values in treatment planning. Clinical target volume (CTV) should be related to external areas of body sections where tumour is located. These areas are important because different radiation beams enter through them. Therefore, verification of the planning target volume (PTV) through the external areas is highly significant. In this work we point out the importance of controlling that PTV is irradiated as planned considering some error sources usually found in radiotherapy practice with equipment that has been intensively used for a long time. Moreover, I think this experience will be helpful for those centers around the world where radiation treatment is carried out with reconditioned units. (author).

  3. Simulation and radiation treatment in external radiotherapy

    International Nuclear Information System (INIS)

    Singer, E.

    1996-01-01

    It is well known that in order to obtain a uniform dose in the treated volume as defined in ICRU 50, there should be a 10% maximum difference between maximum and minimum dose values in treatment planning. Clinical target volume (CTV) should be related to external areas of body sections where tumour is located. These areas are important because different radiation beams enter through them. Therefore, verification of the planning target volume (PTV) through the external areas is highly significant. In this work we point out the importance of controlling that PTV is irradiated as planned considering some error sources usually found in radiotherapy practice with equipment that has been intensively used for a long time. Moreover, I think this experience will be helpful for those centers around the world where radiation treatment is carried out with reconditioned units. (author)

  4. Gastro-intestinal and genito-urinary morbidity after 3D conformal radiotherapy of prostate cancer: observations of a randomized trial

    International Nuclear Information System (INIS)

    Koper, Peter C.; Jansen, Peter; Putten, Wim van; Os, Marjolein van; Wijnmaalen, Arend J.; Lebesque, Joos V.; Levendag, Peter C.

    2004-01-01

    Background and purpose: The late morbidity of a randomized study was analyzed after a follow up of 2 years. The difference in intestinal morbidity was analyzed as a function of the treatment arm and dose volume parameters. The correlation with acute toxicity and (pre-existing) bowel complaints was investigated. Patients and methods: 266 T1-4N0M0 prostate cancer patients were randomized for conventional (open fields) and 3D conformal radiotherapy using beams eye view blocked fields with the same dose (66 Gy) and gross target volume-planning target volume margin (15 mm). Apart from the RTOG toxicity scoring system a patient self-assessment questionnaire was used to obtain detailed information on morbidity. Results: At 2 years there is only a trend for less rectal toxicity (grade≥1) in favor of the conformal radiotherapy (grade 1, 47 versus 40% and grade 2, 10 versus 7% for conventional and conformal radiotherapy, respectively (P=0.1). A significant relation was found between late rectal toxicity (grade≥1) and the volume of the anus and rectum exposed to≥90% tumor dose (TD). A highly significant relationship is observed between acute rectum and anal toxicity and late rectal toxicity. The patient self-assessment questionnaire analysis revealed that patients are most bothered by compliance related symptoms like urgency, soiling and fecal loss. In a multivariate analysis, all other variables loose significance, when anal volume exposed to≥90% TD and pre-treatment defaecation frequency are accounted for. Late anal toxicity is low and related only to acute anal toxicity. Late bladder toxicity is related solely to pre-treatment frequency and overall urological symptoms. The incidence of grade 2 toxicity increases with a factor 2.5-4 when (stool or urine) frequency is unfavorable at the start of treatment. Conclusions: Conformal radiotherapy at the dose level of 66 Gy does not significantly decrease the incidence of rectal, anal and bladder toxicity compared to

  5. A method of analyzing rectal surface area irradiated and rectal complications in prostate conformal radiotherapy

    International Nuclear Information System (INIS)

    Lu Yong; Song, Paul Y.; Li Shidong; Spelbring, Danny R.; Vijayakumar, Srinivasan; Haraf, Daniel J.; Chen, George T.Y.

    1995-01-01

    Purpose: To develop a method of analyzing rectal surface area irradiated and rectal complications in prostate conformal radiotherapy. Methods and Materials: Dose-surface histograms of the rectum, which state the rectal surface area irradiated to any given dose, were calculated for a group of 27 patients treated with a four-field box technique to a total (tumor minimum) dose ranging from 68 to 70 Gy. Occurrences of rectal toxicities as defined by the Radiation Therapy Oncology Group (RTOG) were recorded and examined in terms of dose and rectal surface area irradiated. For a specified end point of rectal complication, the complication probability was analyzed as a function of dose irradiated to a fixed rectal area, and as a function of area receiving a fixed dose. Lyman's model of normal tissue complication probability (NTCP) was used to fit the data. Results: The observed occurrences of rectal complications appear to depend on the rectal surface area irradiated to a given dose level. The patient distribution of each toxicity grade exhibits a maximum as a function of percentage surface area irradiated, and the maximum moves to higher values of percentage surface area as the toxicity grade increases. The dependence of the NTCP for the specified end point on dose and percentage surface area irradiated was fitted to Lyman's NTCP model with a set of parameters. The curvature of the NTCP as a function of the surface area suggests that the rectum is a parallel structured organ. Conclusions: The described method of analyzing rectal surface area irradiated yields interesting insight into understanding rectal complications in prostate conformal radiotherapy. Application of the method to a larger patient data set has the potential to facilitate the construction of a full dose-surface-complication relationship, which would be most useful in guiding clinical practice

  6. Late injury of the eye after conformation radiotherapy for carcinoma of the maxillary sinus

    International Nuclear Information System (INIS)

    Morita, Kozo

    1975-01-01

    Late injury of the eye after radiotherapy for 26 patients with carcinoma of the maxillary sinus was discussed. The conformation technique, a kind of improved rotational technique, was used as the method for radiotherapy. The eyes were shielded by a tungsten- or zinc-rod during irradiation. On the healthy-sided eye, which had received a total dose of 1000-1100 rads/6 weeks (max. 1460 rads/6 weeks), no impairment of vision was seen. On the ill-sided eye given a dose of more than 6000 rads/6 weeks, severe panophthalmopathy with corneal ulceration was observed within 1 year after irradiation. Serious deterioration of visual acuity alway occurred 1.5-2 years after on irradiation of the level of 4000 rads/6 weeks. At present the weakening of visual acuity is unlikely to occur after a dose of less than 3000 rads/6 weeks to the lens. From these results it is recommended that the total dose of the eye be reduced to less than 3000 rads/6 weeks. (author)

  7. A federal audit of the Belgian radiotherapy departments in breast cancer treatment

    International Nuclear Information System (INIS)

    Houtte, Paul van; Bourgois, Nicolas; Renard, Francoise; Huget, Philippe; D'hoore, William; Scalliet, Pierre

    2007-01-01

    Background: The Belgian Federal College of Radiotherapy carried out an external audit of breast cancer patient documentation in the 26 Belgian radiotherapy centres. The objective was to assess compliance with the recommendations regarding minimal requirements for documentation of radiotherapy prescription and administration. All centres volunteered to take part in this audit. Methods: Two experienced radiation oncologists site-visited the departments over a 6 month period (Sept. 2003-Feb. 2004), with a list of items to be verified, including details on the surgery, the pathological report, details on systemic treatments, details on the radiotherapy prescription (and consistency with therapeutic guidelines) and delay surgery/radiotherapy. Findings: Three hundred and eighty-nine patients files were reviewed, for a total of 399 breast cancers (10 patients with bilateral cancer). Mean age was 57.8 y (range 29-96). Breast conservative surgery (BCS) was used in 71%; radical mastectomy in 29%. A complete pathological report was present in all files but 2 (99.5% conformity). 5.2% were treated for DCIS, 61.6% for pT1, 28.2% for pT2 and 5% for pT3-4. Data regarding resection margins were specified to be free in 76.2%, tangential in 12% (within 2 mm) and positive for DCIS in 3.8% or invasive cancer in 1.5% (no information, on margins in 6.5%). The pT stage was always specified, and consistent with the macroscopic and microscopic findings. Hormonal receptors were routinely assessed (94.7%), as well as Her2neu (87.4%). Axillary surgery was carried out in 92%, either by sentinel node biopsy or by complete clearance, in which case the median number of nodes analysed was 12 for all centres together (7-17). All radiotherapy prescriptions were in line with evidence-based standards of therapy (i.e., irradiation of breast after BCS or after mamectomy (in case of pN+), but one. The mean delay between surgery and radiotherapy was 5.5 weeks (SD 11days). Conclusion: There was a high

  8. Quality of Life and Survival Outcome for Patients With Nasopharyngeal Carcinoma Receiving Three-Dimensional Conformal Radiotherapy vs. Intensity-Modulated Radiotherapy-A Longitudinal Study

    International Nuclear Information System (INIS)

    Fang, F.-M.; Chien, C.-Y.; Tsai, W.-L.; Chen, H.-C.; Hsu, H.-C.; Lui, C.-C.; Huang, T.-L.

    2008-01-01

    Purpose: To investigate the changes of quality of life (QoL) and survival outcomes for patients with nasopharyngeal carcinoma (NPC) treated by three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT). Methods and Materials: Two hundred and three newly diagnosed NPC patients, who were curatively treated by 3D-CRT (n = 93) or IMRT (n = 110) between March 2002 and July 2004, were analyzed. The distributions of clinical stage according to American Joint Committee on Cancer 1997 were I: 15 (7.4%), II: 78 (38.4%), III: 74 (36.5%), and IV: 36 (17.7%). QoL was longitudinally assessed by the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 and the EORTC QLQ-H and N35 questionnaires at the five time points: before RT, during RT (36 Gy), and 3 months, 12 months, and 24 months after RT. Results: The 3-year locoregional control, metastasis-free survival, and overall survival rates were 84.8%, 76.7%, and 81.7% for the 3D-CRT group, respectively, compared with 84.2%, 82.6%, and 85.4% for the IMRT group (p value > 0.05). A general trend of maximal deterioration in most QoL scales was observed during RT, followed by a gradual recovery thereafter. There was no significant difference in most scales between the two groups at each time point. The exception was that patients treated by IMRT had a both statistically and clinically significant improvement in global QoL, fatigue, taste/smell, dry mouth, and feeling ill at the time point of 3 months after RT. Conclusions: The potential advantage of IMRT over 3D-CRT in treating NPC patients might occur in QoL outcome during the recovery phase of acute toxicity

  9. The therapeutic effect of three-dimensional conformal radiation therapy combined with conventional radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Liang Feng; Lu Zhonghong; Yao Zhijun; Cao Yongzhen

    2011-01-01

    Objective: To observe the therapeutic effect of three-dimensional conformal radiation therapy (3DCRT) for nasopharyngeal carcinoma (NPC). Methods: 78 patients with NPC was treated by radiation schedule in two phases. In the first phase, nasopharyngeal lesions and metastases of all patients were treated by three-dimensional conformal radiation therapy (3DCRT) with a fraction of 2-5 Gy daily, 5 day per weeks, total dose 30 Gy. The second phase T1N0 or parts of T2N0 patients were done by Conventional radiotherapy with total dose 55 Gy on two small lateral opposing fields + with total dose 50 Gy on neck on tangential field,adding a 3 cm block. Patients with lymph node metastasis were given 55 Gy on the dacio-neck field (After 40 Gy, two small lateral opposing fields were used to boost the primary tumor while the spinal cord shielded) + with total dose 55 Gy on lower neck on tangential field. The upper bound of designed therapeutic field was set to connect with lower bound of main therapeutic field. Results: Three months after treatment,the rate of CR, PR, SD, PD were 38.5%, 55.1%, 5.1%, 1.3%, Total effective rate (CR+PR) were 93.6%. The 1-year, 2-year, 3-year and 5-year local-regional control rates were 92.3%, 88.5%, 78.2%, 70.5%.The 1-year, 2-year , 3-year and 5-year overall survival rate were 96.2%, 89.7%, 83.3%, 71.8%. Appearing early radiation response is well tolerated and no obviously mouth difficulties and cranial nerve damage observed. Conclusion: Clinical result of early-course three-dimensional conformal radiation therapy (3DCRT) for nasopharyngeal carcinoma (NPC) is good. (authors)

  10. Radiotherapy for locally recurrent rectal cancer treated with surgery alone as the initial treatment

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hidekazu; Yamaguchi, Takahiro; Hachiya, Kae; Okada, Sunaho; Kitahara, Masashi; Matsuyama, Katsuya; Matsuo, Masayuki [Gifu University, Gifu (Japan)

    2017-03-15

    Although the technical developments of radiotherapy have been remarkable, there are currently few reports on the treatment results of radiotherapy for local recurrence of rectal cancer treated with surgery alone as initial treatment in this three-dimensional conformal radiotherapy era. Thus, we retrospectively evaluated the treatment results of radiotherapy for local recurrence of rectal cancer treated with surgery alone as the initial treatment. Thirty-two patients who underwent radiotherapy were enrolled in this study. The dose per fraction was 2.0–3.5 Gy. Because the treatment schedule was variable, the biological effective dose (BED) was calculated. Local control (LC) and overall survival (OS) rates from the completion of radiotherapy were calculated. The 1-, 2-, 3-, 4-, and 5-year LC rates were 51.5%, 24.5%, 19.6%, 19.6%, and 13.1%, respectively. LC rates were significantly higher for the high BED group (≥75 Gy10) than for the lower BED group (<75 Gy10). All patients who reported pain achieved pain relief. The duration of pain relief was significantly higher for the high BED group than for the lower BED group. The 1-, 2-, 3-, 4-, and 5-year OS rates were 82.6%, 56.5%, 45.2%, 38.7%, and 23.2%, respectively. There was a trend toward higher OS rates in with higher BED group compared to lower BED group. For patients with unresectable locally recurrent rectal cancer treated with surgery alone, radiotherapy is effective treatment. The prescribed BED should be more than 75 Gy10, if the dose to the organ at risk is within acceptable levels.

  11. Radiotherapy treatments using Tsallis entropy statistical approach

    International Nuclear Information System (INIS)

    Rodríguez-Pérez D; Sotolongo-Grau O; Sotolongo-Costa O; Antoranz J C

    2014-01-01

    Several radiobiological models mimic the biologic effect of one single radiation dose on a living tissue. However, the actual fractionated radiotherapy requires accounting for a new magnitude, i.e., time. Here, we explore the biological consequences posed by the mathematical prolongation of a previous single radiation model to fractionated treatment. The survival fraction is obtained, together with the equivalent physical dose, in terms of a time dependent factor (similar to a repair coefficient) describing the tissue trend to recovering its radioresistance. The model describes how dose fractions add up to obtain the equivalent dose and how the repair coefficient poses a limit to reach an equivalent dose equal to the critical one that would completely annihilate the tumor. On the other hand, the surrounding healthy tissue is a limiting factor to treatment planning. This tissue has its own repair coefficient and thus should limit the equivalent dose of a treatment. Depending on the repair coefficient and the critical dose of each tissue, unexpected results (failure to fully remove the tumor) can be obtained. To illustrate these results and predictions, some realistic example calculations will be performed using parameter values within actual clinical ranges. In conclusion, the model warns about treatment limitations and proposes ways to overcome them

  12. Survey of Stereotactic Body Radiation Therapy in Japan by the Japan 3-D Conformal External Beam Radiotherapy Group

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Hiraoka, Masahiro; Mizowaki, Takashi; Narita, Yuichiro; Matsuo, Yukinori; Norihisa, Yoshiki; Onishi, Hiroshi; Shirato, Hiroki

    2009-01-01

    Purpose: To recognize the current status of stereotactic body radiotherapy (SBRT) in Japan, using a nationwide survey conducted by the Japan 3-D Conformal External Beam Radiotherapy Group. Methods and Materials: The questionnaire was sent by mail to 117 institutions. Ninety-four institutions (80%) responded by the end of November 2005. Fifty-three institutions indicated that they have already started SBRT, and 38 institutions had been reimbursed by insurance. Results: A total of 1111 patients with histologically confirmed lung cancer were treated. Among these patients, 637 had T1N0M0 and 272 had T2N0M0 lung cancer. Metastatic lung cancer was found in 702 and histologically unconfirmed lung tumor in 291 patients. Primary liver cancer was found in 207 and metastatic liver cancer in 76 patients. The most frequent schedule used for primary lung cancer was 48Gy in 4 fractions at 22 institutions (52%), followed by 50Gy in 5 fractions at 11 institutions (26%) and 60Gy in 8 fractions at 4 institutions (10%). The tendency was the same for metastatic lung cancer. The average number of personnel involved in SBRT was 1.8 radiation oncologists, including 1.1 certified radiation oncologists, 2.8 technologists, 0.7 nurses, and 0.6 certified quality assurance personnel and 0.3 physicists. The most frequent amount of time for treatment planning was 61-120min, for quality assurance was 50-60min, and for treatment was 30min. There were 14 (0.6% of all cases) reported Grade 5 complications: 11 cases of radiation pneumonitis, 2 cases of hemoptysis, and 1 case of radiation esophagitis. Conclusion: The current status of SBRT in Japan was surveyed.

  13. A critical evaluation of the planning target volume for 3-d conformal radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Tinger, Alfred; Michalski, Jeff M.; Cheng, Abel; Low, Daniel A.; Zhu, Ron; Bosch, Walter R.; Purdy, James A.; Perez, Carlos A.

    1996-01-01

    Purpose: The goal was to determine an adequate planning target volume (PTV) margin for three-dimensional conformal radiotherapy (3D CRT) of prostate cancer. The uncertainty in the internal positions of the prostate and seminal vesicles and the uncertainty in the treatment set-ups for a single group of patients was measured. Methods: Weekly computed tomography (CT) scans of the pelvis (n=38) and daily electronic portal images (n=1225) were reviewed for six patients who received seven-field 3D CRT for prostate cancer. The weekly CT scans were registered in three dimensions to the original treatment planning CT scan using commercially available software. This registration permitted measurement of the motion in the center-of-volume (COV) of the prostate and seminal vesicles throughout the course of therapy. The daily portal images (PI) were registered to the corresponding simulation films to measure the set-up displacement for each of the seven fields. The field displacements were then entered into a matrix program which calculated the isocenter displacement by a least squares method. The uncertainty in the internal positions of the prostate and seminal vesicles (standard deviation of the motions) was added to the uncertainty in the set-up (standard deviation of the isocenter displacements) in quadrature to arrive at a total uncertainty. Positive directions were defined in the left, anterior, and superior directions. A discussion of an adequate PTV was based on these results. Results: The mean magnitude of motion for the COV of the prostate ± the standard deviation was 0 ± 1 mm in the left-right (LR) direction, 0.5 ± 2.8 mm in the anterior-posterior (AP) direction, and 0.5 ± 3.5 mm in the superior-inferior (SI) direction. The mean magnitude of motion for the COV of the seminal vesicles ± the standard deviation was -0.3 ± 1.5 mm in the LR, 0.6 ± 4.1 mm in the AP, and 0.7 ± 2.3 mm in the SI directions, respectively. For all patients the mean isocenter

  14. A computer-controlled high resolution micro-multi-leaf collimator for stereotactic conformal radio-therapy

    International Nuclear Information System (INIS)

    Schlegel, Wolfgang; Pastyr, Otto; Kubesch, Rudolf; Diemer, Torsten; Kuester, Gunnilla; Rhein, Bernhard; Hoever, Karl-Heinz

    1997-01-01

    Purpose/Objective In stereotactic conformal radiotherapy of irregularly shaped lesions, either multi-isocentric convergent beam treatment techniques with circular collimators or irregular shaped beams are being used. While the treatment technique with multiple isocenters has the disadvantage of producing inhomogeneous dose distributions, the use of irregular shaped fields is not yet satisfying from a technical point of view: Cerrobend blocking or the use of static micro MLCs need a long preparation time and only allow static treatment techniques, MLC collimators which are commercially available in connection with modern LINACs have leaf-thickness of at least 1 cm which is too coarse for stereotactic radiotherapy of lesions in the brain and head and neck area. For this reason, we developed a computer controlled micro-MLC with technical specifications matched to the needs of stereotactic radiotherapy and radiosurgery. Materials and Methods The mechanical specifications of the computer controlled micro-MLC were derived from our experience with stereotactic treatment techniques, from the requirement that the MLC has to be attachable as an external device to the accessory holders of standard LINACs, including cost considerations, dosimetric measurements as well as Monte Carlo calculations. The Micro-MLC is controlled by an electronic equipment consisting of a standard PC under Windows 95, an interface board, 14 Micro-controller boards, a verification system and 80 driving units equipped with DC motors and potentiometers. The control program has calibrating, operating, visualizing and test options. Irregular field data are transferred from the treatment planning computer to the control PC and distributed to the micro-controllers, which in parallel are driving three leaves each. Beside the special control unit, we are currently investigating whether the electronics of commercially available integrated large field MLCs can also be used for operating the Micro-MLC. Results

  15. Radiotherapy in the treatment of multiple myeloma.

    Science.gov (United States)

    Bosch, A; Frias, Z

    1988-12-01

    Fifty-nine patients with multiple myeloma referred for treatment of painful bony lesions received irradiation to 95 local areas, and 16 of the 59 were irradiated using hemibody techniques. Pain relief was obtained in practically all of the irradiated regions. Most local areas were treated to doses of 3000 cGy in 10 to 15 fractions. Patients with generalized pain due to multiple site involvement were treated with single dose hemibody irradiation, to doses of 600 cGy to the upper hemibody, and of 800 cGy to the lower hemibody. This treatment was well tolerated and side effects minimal. Median survival from diagnosis was 30 months and the survival at 1, 3, and 5 years was 80%, 42%, and 12% respectively. Key articles on radiation therapy of multiple myeloma are reviewed and discussed. Since all patients eventually relapse after chemotherapy, the role of radiotherapy using present techniques should be fully evaluated and considered as an alternative in the primary treatment of multiple myeloma.

  16. Radiotherapy for Adult Medulloblastoma: Evaluation of Helical Tomotherapy, Volumetric Intensity Modulated Arc Therapy, and Three-Dimensional Conformal Radiotherapy and the Results of Helical Tomotherapy Therapy

    Directory of Open Access Journals (Sweden)

    Sun Zong-wen

    2018-01-01

    Full Text Available Introduction. All adult medulloblastoma (AMB patients should be treated with craniospinal irradiation (CSI postoperatively. Because of the long irradiation range, multiple radiation fields must be designed for conventional radiotherapy technology. CSI can be completed in only one session with helical tomotherapy (HT. We evaluated the dose of HT, volumetric intensity modulated arc therapy (VMAT, and three-dimensional conformal radiotherapy (3D-CRT of AMB and the results of 5 cases of AMB treated with HT. Methods. Complete craniospinal and posterior cranial fossa irradiation with HT, VMAT, and 3D-CRT and dose evaluation were performed. And results of 5 cases of AMB treated with HT were evaluated. Results. A large volume of tissue was exposed to low dose radiation in the organs at risk (OAR, while a small volume was exposed to high dose radiation with HT. The conformity and uniformity of the targets were good with HT and VMAT, and the volume of targets exposed to high dose with VMAT was larger than that of HT. The uniformity of 3D-CRT was also good, but the dose conformity was poor. The main toxicity was hematologic toxicity, without 4th-degree bone marrow suppression. There was 3rd-degree inhibition in the white blood cells, hemoglobin, and platelets. The three female patients suffered menstrual disorders during the course of radiation. Two female patients with heavy menstruation suffered 3rd-degree anemia inhibition, and 2 patients suffered amenorrhea after radiotherapy. Although menstrual cycle was normal, the third patient was not pregnant. Conclusion. CSI with HT is convenient for clinical practice, and the side effects are mild. With good conformity and uniformity, VMAT can also be used for selection in CSI. For poor conformity, 3D-CRT should not be the priority selection for CSI. In female patients, the ovaries should be protected.

  17. 3-D conformal radiation therapy - Part I: Treatment planning

    International Nuclear Information System (INIS)

    Burman, Chandra M.; Mageras, Gikas S.

    1997-01-01

    Objective: In this presentation we will look into the basic components of 3-dimensional conformal treatment planning, and will discuss planning for some selected sites. We will also review some current and future trends in 3-D treatment planning. External beam radiation therapy is one of the arms of cancer treatment. In the recent years 3-D conformal therapy had significant impact on the practice of external beam radiation therapy. Conformal radiation therapy shapes the high-dose volume so as to conform to the target volume while minimizing the dose to the surrounding normal tissues. The advances that have been achieved in conformal therapy are in part due to the development of 3-D treatment planning, which in turn has capitalized on 3-D imaging for tumor and normal tissue localization, as well as on available computational power for the calculation of 3-D dose distributions, visualization of anatomical and dose volumes, and numerical evaluation of treatment plans. In this course we will give an overview of how 3-D conformal treatments are designed and transferred to the patient. Topics will include: 1) description of the major components of a 3-D treatment planning system, 2) techniques for designing treatments, 3) evaluation of treatment plans using dose distribution displays, dose-volume histograms and normal tissue complication probabilities, 4) implementation of treatments using shaped blocks and multileaf collimators, 5) verification of treatment delivery using portal films and electronic portal imaging devices. We will also discuss some current and future trends in 3-D treatment planning, such as field shaping with multileaf collimation, computerized treatment plan optimization, including the use of nonuniform beam profiles (intensity modulation), and incorporating treatment uncertainties due to patient positioning errors and organ motion into treatment planning process

  18. Radiotherapy.

    Science.gov (United States)

    Krause, Sonja; Debus, Jürgen; Neuhof, Dirk

    2011-01-01

    Solitary plasmocytoma occurring in bone (solitary plasmocytoma of the bone, SBP) or in soft tissue (extramedullary plasmocytoma, EP) can be treated effectively and with little toxicity by local radiotherapy. Ten-year local control rates of up to 90% can be achieved. Patients with multiple myeloma often suffer from symptoms such as pain or neurological impairments that are amenable to palliative radiotherapy. In a palliative setting, short treatment schedules and lower radiation doses are used to reduce toxicity and duration of hospitalization. In future, low-dose total body irradiation (TBI) may play a role in a potentially curative regimen with nonmyeloablative conditioning followed by allogenic peripheral blood stem cell transplantation.

  19. Optimal hypofractionated conformal radiotherapy for large brain metastases in patients with high risk factors: a single-institutional prospective study

    International Nuclear Information System (INIS)

    Inoue, Hiroshi K; Sato, Hiro; Suzuki, Yoshiyuki; Saitoh, Jun-ichi; Noda, Shin-ei; Seto, Ken-ichi; Torikai, Kota; Sakurai, Hideyuki; Nakano, Takashi

    2014-01-01

    A single-institutional prospective study of optimal hypofractionated conformal radiotherapy for large brain metastases with high risk factors was performed based on the risk prediction of radiation-related complications. Eighty-eight patients with large brain metastases ≥10 cm 3 in critical areas treated from January 2010 to February 2014 using the CyberKnife were evaluated. The optimal dose and number of fractions were determined based on the surrounding brain volume circumscribed with a single dose equivalent (SDE) of 14 Gy (V14) to be less than 7 cm 3 for individual lesions. Univariate and multivariate analyses were conducted. As a result of optimal treatment, 92 tumors ranging from 10 to 74.6 cm 3 (median, 16.2 cm 3 ) in volume were treated with a median prescribed isodose of 57% and a median fraction number of five. In order to compare the results according to the tumor volume, the tumors were divided into the following three groups: 1) 10–19.9 cm 3 , 2) 20–29.9 cm 3 and 3) ≥30 cm 3 . The lesions were treated with a median prescribed isodose of 57%, 56% and 55%, respectively, and the median fraction number was five in all three groups. However, all tumors ≥20 cm 3 were treated with ≥ five fractions. The median SDE of the maximum dose in the three groups was 47.2 Gy, 48.5 Gy and 46.5 Gy, respectively. Local tumor control was obtained in 90.2% of the patients, and the median survival was nine months, with a median follow-up period of seven months (range, 3-41 months). There were no significant differences in the survival rates among the three groups. Six tumors exhibited marginal recurrence 7-36 months after treatment. Ten patients developed symptomatic brain edema or recurrence of pre-existing edema, seven of whom required osmo-steroid therapy. No patients developed radiation necrosis requiring surgical resection. Our findings demonstrate that the administration of optimal hypofractionated conformal radiotherapy based on the dose-volume prediction

  20. Late xerostomia after intensity-modulated conformational radiotherapy of upper aero-digestive tract cancers: study 2004-03 by the head and neck oncology and radiotherapy Group (Gortec)

    International Nuclear Information System (INIS)

    Toledano, I.; Lapeyre, M.; Graff, P.; Serre, C.; Bensadoun, R.J.; Bensadoun, R.J.; Ortholan, C.; Calais, G.; Alfonsi, M.; Giraud, P.; Racadot, S.

    2010-01-01

    The authors report a retrospective assessment of late xerostomia according to the RTOG (Radiation Therapy Oncology Group) classification of the European Organization for Research and Treatment of Cancer (EORTC) among patients treated by intensity-modulated conformational radiotherapy (IMRT) and suffering from upper aero-digestive tract carcinomas of different stages. Some of these patients have bee operated, and some have been treated by chemotherapy. It appears that the IMRT results in a reduction of late xerostomia, and even in an absence of salivary toxicity. Short communication

  1. Collision prediction software for radiotherapy treatments

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, Laura [Virginia Commonwealth University Medical Center, Richmond, Virginia 23298 (United States); Pearson, Erik A. [Techna Institute and the Princess Margaret Cancer Center, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Pelizzari, Charles A., E-mail: c-pelizzari@uchicago.edu [Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637 (United States)

    2015-11-15

    Purpose: This work presents a method of collision predictions for external beam radiotherapy using surface imaging. The present methodology focuses on collision prediction during treatment simulation to evaluate the clearance of a patient’s treatment position and allow for its modification if necessary. Methods: A Kinect camera (Microsoft, Redmond, WA) is used to scan the patient and immobilization devices in the treatment position at the simulator. The surface is reconstructed using the SKANECT software (Occipital, Inc., San Francisco, CA). The treatment isocenter is marked using simulated orthogonal lasers projected on the surface scan. The point cloud of this surface is then shifted to isocenter and converted from Cartesian to cylindrical coordinates. A slab models the treatment couch. A cylinder with a radius equal to the normal distance from isocenter to the collimator plate, and a height defined by the collimator diameter is used to estimate collisions. Points within the cylinder clear through a full gantry rotation with the treatment couch at 0° , while points outside of it collide. The angles of collision are reported. This methodology was experimentally verified using a mannequin positioned in an alpha cradle with both arms up. A planning CT scan of the mannequin was performed, two isocenters were marked in PINNACLE, and this information was exported to AlignRT (VisionRT, London, UK)—a surface imaging system for patient positioning. This was used to ensure accurate positioning of the mannequin in the treatment room, when available. Collision calculations were performed for the two treatment isocenters and the results compared to the collisions detected the room. The accuracy of the Kinect-Skanect surface was evaluated by comparing it to the external surface of the planning CT scan. Results: Experimental verification results showed that the predicted angles of collision matched those recorded in the room within 0.5°, in most cases (largest deviation

  2. Hypofractionated three-dimensional conformal radiotherapy for medically inoperable early stage

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Ho; Wu, Hong Gyun; KIm, Hak Jae; Park, Charn Il; Lee, Se Hoon; Kim, Dong Wan; Heo, Dae Seong [Seoul National University College of Medicine, Seou (Korea, Republic of)

    2013-01-15

    The purpose of this study was to assess the clinical outcomes of hypofractionated radiotherapy (HFRT) with three-dimensional conformal technique for medically inoperable patients with early stage non-small-cell lung cancer (NSCLC) and to evaluate prognostic factors. We performed a retrospective review of 26 patients who underwent HFRT for early stage NSCLC between September 2005 and August 2011. Only clinical stage T1-3N0 was included. The median RT dose was 70 Gy (range, 60 to 72 Gy) and the median biologically equivalent dose (BED) was 94.5 Gy (range, 78.0 to 100.8 Gy). In 84.6% of patients, 4 Gy per fraction was used. Neoadjuvant chemotherapy with paclitaxel and cisplatin was given to 2 of 26 patients. The median follow-up time for surviving patients was 21 months (range, 13 to 49 months). The overall response rate was 53.9%, and the initial local control rate was 100%. The median survival duration was 27.8 months. Rates of 2-year overall survival, progression-free survival (PFS), local control (LC), and locoregional-free survival (LRFS) were 54.3%, 61.1%, 74.6%, and 61.9%, respectively. Multivariate analysis showed that BED (>90 vs. {<=}90 Gy) was an independent prognostic factor influencing PFS, LC, and LRFS. Severe toxicities over grade 3 were not observed. Radical HFRT can yield satisfactory disease control with acceptable rates of toxicities in medically inoperable patients with early stage NSCLC. HFRT is a viable alternative for clinics and patients ineligible for stereotactic ablative radiotherapy. BED over 90 Gy and 4 Gy per fraction might be appropriate for HFRT.

  3. Setup error in three-dimensional conformal radiotherapy for thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Hong Jinsheng; Zhang Weijian; Chen Jinmei; Cai Chuanshu; Ke Chunlin; Chen Xiuying; Wu Bing; Guo Feibao

    2009-01-01

    Objective: To study the setup errors in three-dimensional conformal radiotherapy (3DCRT) for thoracic esophageal carcinoma using electronic portal imaging device(EPID) and calculate the margins from CTV to PTV. Methods: Forty-one patients with thoracic esophageal carcinoma who received 3DCRT were continuously enrolled into this study. The anterior and lateral electronic portal images (EPI) were aquired by EPID once a week. The setup errors were obtained through comparing the difference between EPI and digitally reconstructed radiographs (DRR). Then the setup margins from CTV to PTV were calculated. By using self paired design, 22 patients received definitive radiotherapy with different margins. Group A: the margins were 10 mm in all the three axes; Group B: the margins were aquired in this study. The difference were compared by Paired t-test or Wilcoxon signed-rank test. Results: The margins from CTV to PTV in x, y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. Between the group A and group B, the difference of the maximum dose of the spinal cord was significant(4638.7 cGy ± 1449.6 cGy vs. 4310.2 cGy ± 1528.7 cGy; t=5.48, P=0.000), and the difference of NTCP for the spinal cord was also significant (4.82% ± 5.99% vs. 3.64% ± 4.70%; Z=-2.70, P=0.007). Conclusions: For patients with thoracic esophageal carcinoma who receive 3DCRT in author's department, the margins from CTV to PTV in x, y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. The spinal cord could be better protected by using these setup margins than using 10 mm in each axis. (authors)

  4. Evidence-based review of three-dimensional conformal radiotherapy for localized prostate cancer: An ASTRO outcomes initiative

    International Nuclear Information System (INIS)

    Morris, David E.; Emami, Bahman; Mauch, Peter M.; Konski, Andre A.; Tao, May L.; Ng, Andrea K.; Klein, Eric A.; Mohideen, Najeeb; Hurwitz, Mark D.; Fraas, Bendick A.; Roach, Mack; Gore, Elizabeth M.; Tepper, Joel E.

    2005-01-01

    Purpose: To perform a systematic review of the evidence to determine the efficacy and effectiveness of three-dimensional conformal radiotherapy (3D-CRT) for localized prostate cancer; provide a clear presentation of the key clinical outcome questions related to the use of 3D-CRT in the treatment of localized prostate cancer that may be answered by a formal literature review; and provide concise information on whether 3D-CRT improves the clinical outcomes in the treatment of localized prostate cancer compared with conventional RT. Methods and Materials: We performed a systematic review of the literature through a structured process developed by the American Society for Therapeutic Radiology and Oncology's Outcomes Committee that involved the creation of a multidisciplinary task force, development of clinical outcome questions, a formal literature review and data abstraction, data review, and outside peer review. Results: Seven key clinical questions were identified. The results and task force conclusions of the literature review for each question are reported. Conclusion: The technological goals of reducing morbidity with 3D-CRT have been achieved. Randomized trials and follow-up of completed trials remain necessary to address these clinical outcomes specifically with regard to patient subsets and the use of hormonal therapy

  5. Automated radiotherapy treatment plan integrity verification

    Energy Technology Data Exchange (ETDEWEB)

    Yang Deshan; Moore, Kevin L. [Department of Radiation Oncology, School of Medicine, Washington University in Saint Louis, St. Louis, Missouri 63110 (United States)

    2012-03-15

    Purpose: In our clinic, physicists spend from 15 to 60 min to verify the physical and dosimetric integrity of radiotherapy plans before presentation to radiation oncology physicians for approval. The purpose of this study was to design and implement a framework to automate as many elements of this quality control (QC) step as possible. Methods: A comprehensive computer application was developed to carry out a majority of these verification tasks in the Philips PINNACLE treatment planning system (TPS). This QC tool functions based on both PINNACLE scripting elements and PERL sub-routines. The core of this technique is the method of dynamic scripting, which involves a PERL programming module that is flexible and powerful for treatment plan data handling. Run-time plan data are collected, saved into temporary files, and analyzed against standard values and predefined logical rules. The results were summarized in a hypertext markup language (HTML) report that is displayed to the user. Results: This tool has been in clinical use for over a year. The occurrence frequency of technical problems, which would cause delays and suboptimal plans, has been reduced since clinical implementation. Conclusions: In addition to drastically reducing the set of human-driven logical comparisons, this QC tool also accomplished some tasks that are otherwise either quite laborious or impractical for humans to verify, e.g., identifying conflicts amongst IMRT optimization objectives.

  6. Automated radiotherapy treatment plan integrity verification

    International Nuclear Information System (INIS)

    Yang Deshan; Moore, Kevin L.

    2012-01-01

    Purpose: In our clinic, physicists spend from 15 to 60 min to verify the physical and dosimetric integrity of radiotherapy plans before presentation to radiation oncology physicians for approval. The purpose of this study was to design and implement a framework to automate as many elements of this quality control (QC) step as possible. Methods: A comprehensive computer application was developed to carry out a majority of these verification tasks in the Philips PINNACLE treatment planning system (TPS). This QC tool functions based on both PINNACLE scripting elements and PERL sub-routines. The core of this technique is the method of dynamic scripting, which involves a PERL programming module that is flexible and powerful for treatment plan data handling. Run-time plan data are collected, saved into temporary files, and analyzed against standard values and predefined logical rules. The results were summarized in a hypertext markup language (HTML) report that is displayed to the user. Results: This tool has been in clinical use for over a year. The occurrence frequency of technical problems, which would cause delays and suboptimal plans, has been reduced since clinical implementation. Conclusions: In addition to drastically reducing the set of human-driven logical comparisons, this QC tool also accomplished some tasks that are otherwise either quite laborious or impractical for humans to verify, e.g., identifying conflicts amongst IMRT optimization objectives.

  7. Analysis of clinical and dosimetric factors associated with treatment-related pneumonitis (TRP) in patients with non-small-cell lung cancer (NSCLC) treated with concurrent chemotherapy and three-dimensional conformal radiotherapy (3D-CRT)

    International Nuclear Information System (INIS)

    Wang Shulian; Liao Zhongxing; Wei Xiong; Liu, Helen H.; Tucker, Susan L.; Hu Chaosu; Mohan, Rodhe; Cox, James D.; Komaki, Ritsuko

    2006-01-01

    Purpose: To investigate factors associated with treatment-related pneumonitis in non-small-cell lung cancer patients treated with concurrent chemoradiotherapy. Patients and Methods: We retrospectively analyzed data from 223 patients treated with definitive concurrent chemoradiotherapy. Treatment-related pneumonitis was graded according to Common Terminology Criteria for Adverse Events version 3.0. Univariate and multivariate analyses were performed to identify predictive factors. Results: Median follow-up was 10.5 months (range, 1.4-58 months). The actuarial incidence of Grade ≥3 pneumonitis was 22% at 6 months and 32% at 1 year. By univariate analyses, lung volume, gross tumor volume, mean lung dose, and relative V5 through V65, in increments of 5 Gy, were all found to be significantly associated with treatment-related pneumonitis. The mean lung dose and rV5-rV65 were highly correlated (p 42% were 3% and 38%, respectively (p = 0.001). Conclusions: In this study, a number of clinical and dosimetric factors were found to be significantly associated with treatment-related pneumonitis. However, rV5 was the only significant factor associated with this toxicity. Until it is better understood which dose range is most relevant, multiple clinical and dosimetric factors should be considered in treatment planning for non-small-cell lung cancer patients receiving concurrent chemoradiotherapy

  8. Evaluation of homogeneity and dose conformity in IMRT planning in prostate radiotherapy

    International Nuclear Information System (INIS)

    Lopes, Juliane S.; Leidens, Matheus; Estacio, Daniela R.; Razera, Ricardo A.Z.; Streck, Elaine E.; Silva, Ana M.M. da

    2015-01-01

    The goal of this study was to evaluate the dose distribution homogeneity and conformity of radiation therapy plans of prostate cancer using IMRT. Data from 34 treatment plans of Hospital Sao Lucas of PUCRS, where those plans were executed, were retrospectively analyzed. All of them were done with 6MV X-rays from a linear accelerator CLINAC IX, and the prescription doses varied between 60 and 74 Gy. Analyses showing the homogeneity and conformity indices for the dose distribution of those plans were made. During these analyses, some comparisons with the traditional radiation therapy planning technic, the 3D-CRT, were discussed. The results showed that there is no correlation between the prescribed dose and the homogeneity and conformity indices, indicating that IMRT works very well even for higher doses. Furthermore, a comparison between the results obtained and the recommendations of ICRU 83 was carried out. It has also been observed that the indices were really close to the ideal values. 82.4% of the cases showed a difference below 5% of the ideal value for the index of conformity, and 88.2% showed a difference below 10% for the homogeneity index. Concluding, it is possible to confirm the quality of the analyzed radiation therapy plans of prostate cancer using IMRT. (author)

  9. Long-Term Results of Conformal Radiotherapy for Progressive Airway Amyloidosis

    Energy Technology Data Exchange (ETDEWEB)

    Truong, Minh Tam, E-mail: mitruong@bu.edu [Department of Radiation Oncology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Kachnic, Lisa A. [Department of Radiation Oncology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Grillone, Gregory A. [Department of Otolaryngology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Bohrs, Harry K.; Lee, Richard [Department of Radiation Oncology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Sakai, Osamu [Department of Radiology, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States); Berk, John L. [Department of Medicine, Amyloid Treatment and Research Program, Boston University School of Medicine, Boston Medical Center, Boston, MA (United States)

    2012-06-01

    Purpose: To evaluate the efficacy of conformal external beam radiotherapy (RT) for local control of progressive airway amyloidosis. Methods and Materials: We conducted a retrospective review of patients with biopsy-proven progressive airway amyloidosis treated with conformal RT between 2000 and 2006 at Boston Medical Center. The patients were evaluated for performance status and pulmonary function, with computed tomography and endoscopy after RT compared with the pretreatment studies. Local control was defined as the lack of progression of airway wall thickening on computed tomography imaging and stable endobronchial deposits by endoscopy. Results: A total of 10 symptomatic airway amyloidosis patients (3 laryngeal and 7 tracheobronchial) received RT to a median total dose of 20 Gy in 10 fractions within 2 weeks. At a median follow-up of 6.7 years (range, 1.5-10.3), 8 of the 10 patients had local control. The remaining 2 patients underwent repeat RT 6 and 8.4 months after initial RT, 1 for persistent bronchial obstruction and 1 for progression of subglottic amyloid disease with subsequent disease control. The Eastern Cooperative Oncology Group performance status improved at a median of 18 months after RT compared with the baseline values, from a median score of 2 to a median of 1 (p = .035). Airflow (forced expiratory volume in 1 second) measurements increased compared with the baseline values at each follow-up evaluation, reaching a 10.7% increase (p = .087) at the last testing (median duration, 64.8 months). Acute toxicity was limited to Grade 1-2 esophagitis, occurring in 40% of patients. No late toxicity was observed. Conclusions: RT prevented progressive amyloid deposition in 8 of 10 patients, resulting in a marginally increased forced expiratory volume in 1 second, and improved functional capacity, without late morbidity.

  10. Dosimetric and clinical results of three-dimensional conformal radiotherapy for locally recurrent nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zheng Xiaokang; Ma Jun; Chen Longhua; Xia Yunfei; Shi Yusheng

    2005-01-01

    Purpose: To assess the dosimetric and clinical results of three-dimensional conformal radiotherapy (3D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: A total of 86 patients with locally recurrent NPC were retreated with 3D CRT. The median prescribed dose was 68 Gy with 2 Gy per fractionation. Dosimetric quality was evaluated with dose distribution in planning target volume (PTV) and specified organs at risk (OAR), dose conformity index (CI) and dose homogeneity index (HI). The actuarial rate of local failure-free (LFF), overall survival (OS) and major late toxicities (MLT) were estimated with Kaplan-Meier method. Multivariate analysis for prognosis was performed using the Cox regression proportional hazards model. Results: The mean dose to PTV averaged 66.8 Gy, and the dose to specified OAR was acceptable. The average value of CI and HI was 0.59 and 9.1%. The 5-year actuarial rate of LFF and OS was 71 and 40%, respectively. The 5-year actuarial incidence of MLT≥Grade 3 and ≥Grade 4 were 100 and 49%, respectively. The major prognostic factors were T stage and the size of gross tumor volume (GTV). Advanced T stage and large GTV volume were associated with poor LFF and OS and high risk of MLT. Conclusion: The dosimetric quality of 3D CRT for locally recurrent NPC is generally excellent. A relatively high local control was achieved with this technique. However, the incidence of late toxicities were not found to decrease as originally expected. Early diagnosis of the recurrence and reasonable definition of the target volume are crucial to achieve a better outcome

  11. Comparación de costes de tres tratamientos del cáncer de próstata localizado en España: prostatectomía radical, braquiterapia prostática y radioterapia conformacional externa 3D Cost comparison of three treatments for localized prostate cancer in Spain: radical prostatectomy, prostate brachytherapy and external 3D conformal radiotherapy

    Directory of Open Access Journals (Sweden)

    Virginia Becerra Bachino

    2011-02-01

    statistically significant: medians were €3,229.10, €5,369.00 and €6,265.60, respectively, for the groups of patients treated with external 3D conformal radiotherapy, brachytherapy and radical retropublic prostatectomy, (p<0.001. In the multivariate analysis (adjusted R²=0.8, the average costs of brachytherapy and external radiotherapy were significantly lower than that of prostatectomy (coefficient -0.212 and -0.729, respectively. Conclusions: Radical prostatectomy proved to be the most expensive treatment option. Overall, the estimated costs in our study were lower than those published elsewhere. Most of the costs were explained by the therapeutic option and neither comorbidity nor risk groups showed an effect on total costs independent of treatment.

  12. A comparison of morbidity following conformal versus intensity-modulated radiotherapy for urinary bladder cancer.

    Science.gov (United States)

    Søndergaard, Jimmi; Holmberg, Mats; Jakobsen, Annette Ross; Agerbæk, Mads; Muren, Ludvig Paul; Høyer, Morten

    2014-10-01

    In radiotherapy (RT) of urinary bladder cancer, the use of intensity-modulated RT (IMRT) opens for sparing of considerable intestinal volumes. The purpose of the present study was to investigate the acute and late toxicities following either conformal RT (CRT) or IMRT for bladder cancer, and to correlate the toxicities to dose-volume parameters. The study included 116 consecutively treated patients with muscle-invasive bladder cancer who received either CRT (n = 66) or IMRT (n = 50) during 2007-2010. Acute side effects were retrospectively collected whereas late effects were assessed by a cross-sectional evaluation by telephone interview of 44 recurrence-free patients. Acute and late toxicities were scored according to the Common Terminology Criteria for Adverse Event (CTCAE) version 3.0. Acute diarrhoea grade ≥ 2 was more frequent in patients treated by CRT (56%) compared to IMRT (30%) (p = 0.008). Logistic regression analysis showed a correlation between acute diarrhoea and bowel cavity dose-volume parameters in the 10-50 Gy range. Severe late toxicity (grade ≥ 3) was recorded in 10% of the total cohort, with no statistical difference between the IMRT and CRT groups. Patients treated with IMRT for bladder cancer had significantly less acute diarrhoea compared to those treated with CRT, but there was no significant difference in late morbidity between the groups. The risk of acute diarrhoea was related to the volume of bowel irradiated.

  13. Radiotherapy

    International Nuclear Information System (INIS)

    Pistenma, D.A.

    1980-01-01

    The need for radiotherapy research is exemplified by the 100,000 cancer patients who will fail treatment locally and/or regionally annually for the next several years but who would benefit from better local treatment modalities. Theoretically, all of the areas of investigation discussed in this projection paper have the potential to significantly improve local-regional treatment of cancer by radiotherapy alone or in combination with other modalities. In many of the areas of investigation discussed in this paper encouraging results have been obtained in cellular and animal tumor studies and in limited studies in humans as well. In the not too distant future the number of patients who would benefit from better local control may increase by tens of thousands if developments in chemotherapy and/or immunotherapy provide a means to eradicate disseminated microscopic foci of cancer. Thus the efforts to improve local-regional control take on even greater significance

  14. MR vs CT imaging: low rectal cancer tumour delineation for three-dimensional conformal radiotherapy.

    LENUS (Irish Health Repository)

    O'Neill, B D P

    2009-06-01

    Modern three-dimentional radiotherapy is based upon CT. For rectal cancer, this relies upon target definition on CT, which is not the optimal imaging modality. The major limitation of CT is its low inherent contrast resolution. Targets defined by MRI could facilitate smaller, more accurate, tumour volumes than CT. Our study reviewed imaging and planning data for 10 patients with locally advanced low rectal cancer (defined as < 6 cm from the anal verge on digital examination). Tumour volume and location were compared for sagittal pre-treatment MRI and planning CT. CT consistently overestimated all tumour radiological parameters. Estimates of tumour volume, tumour length and height of proximal tumour from the anal verge were larger on planning CT than on MRI (p < 0.05). Tumour volumes defined on MRI are smaller, shorter and more distal from the anal sphincter than CT-based volumes. For radiotherapy planning, this may result in smaller treatment volumes, which could lead to a reduction in dose to organs at risk and facilitate dose escalation.

  15. Clinical results of conformal versus intensity-modulated radiotherapy using a focal simultaneous boost for muscle-invasive bladder cancer in elderly or medically unfit patients

    International Nuclear Information System (INIS)

    Lutkenhaus, Lotte J.; Os, Rob M. van; Bel, Arjan; Hulshof, Maarten C. C. M.

    2016-01-01

    For elderly or medically unfit patients with muscle-invasive bladder cancer, cystectomy or chemotherapy are contraindicated. This leaves radical radiotherapy as the only treatment option. It was the aim of this study to retrospectively analyze the treatment outcome and associated toxicity of conformal versus intensity-modulated radiotherapy (IMRT) using a focal simultaneous tumor boost for muscle-invasive bladder cancer in patients not suitable for cystectomy. One hundred eighteen patients with T2-4 N0-1 M0 bladder cancer were analyzed retrospectively. Median age was 80 years. Treatment consisted of either a conformal box technique or IMRT and included a simultaneous boost to the tumor. To enable an accurate boost delivery, fiducial markers were placed around the tumor. Patients were treated with 40 Gy in 20 fractions to the elective treatment volumes, and a daily tumor boost up to 55–60 Gy. Clinical complete response was seen in 87 % of patients. Three-year overall survival was 44 %, with a locoregional control rate of 73 % at 3 years. Toxicity was low, with late urinary and intestinal toxicity rates grade ≥ 2 of 14 and 5 %, respectively. The use of IMRT reduced late intestinal toxicity, whereas fiducial markers reduced acute urinary toxicity. Radical radiotherapy using a focal boost is feasible and effective for elderly or unfit patients, with a 3-year locoregional control of 73 %. Toxicity rates were low, and were reduced by the use of IMRT and fiducial markers. The online version of this article (doi:10.1186/s13014-016-0618-6) contains supplementary material, which is available to authorized users

  16. Dosimetry analysis on radiation-induced acute esophagitis after three-dimensional conformal radiotherapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    ZZhu Shuchai; Cui Yanli; Li Juan; Liu Zhikun; Shen Wenbin; Su Jingwei; Wang Yuxiang

    2010-01-01

    Objective: To analyze the related factors with radiation-induced esophagitis after threedimensional conformal radiotherapy for non-small cell lung cancer (NSCLC), in order to explore the predictors for optimizing the treatment planning of NSCLC. Methods: From Aug 2000 to Dec 2004, 104 NSCLC patients received radiotherapy and were eligible for this study, 45 cases squamous cell carcinoma, 20 cases adenocarcinoma, 33 cases carrying with cancer cells by test and 6 case with no definitive pathologic feature.46 patients were treated with three dimensional conformal radiotherapy (3DCRT), the other 58 patients conventional radiotherapy (CRT) before later-course 3DCRT. All the patients received the prescribed dose between 60-78 Gy and the median dose 66 Gy. The correlation of the variables were evaluated by Spearman relationship analysis. The morbidity of radiation-induced esophagitis was analyzed by X 2 test. The multivariate effect on radiation-induced esophagitis was statistically processed by Logistic regression model. Results: In 104 patients, the morbidity of radiation- induced esophagitis was 46.2%, including 32 cases at grade 1, 15 cases at grade 2, 1 case at grade 3. Univariate analysis showed the maximal and mean dose of esophagus, the volume of esophagus irradiated, the values of V 40 , V 45 , V 50 , V 55 , V 60 , LETT 45 , LETT 50 , LETT 55 , LETT 60 for the esophagus were correlated with radiation-induced esophagitis. Logistic regression model showed that the maximum dose received by the esophagus was the independent factor of ≥ 2 grade radiation-induced esophagitis. Conclusions: The maxmal dose of esophagus received might be the important factor of radiation-induced esophagitis. (authors)

  17. Sexual Function After Three-Dimensional Conformal Radiotherapy for Prostate Cancer: Results From a Dose-Escalation Trial

    International Nuclear Information System (INIS)

    Wielen, Gerard J. van der; Putten, Wim van; Incrocci, Luca

    2007-01-01

    Purpose: The purpose of this study is to provide information about sexual function (SF) after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer while taking important factors into account that influence SF. Methods and Materials: Between June 1997 and February 2003, a total of 268 patients from a randomized dose-escalation trial comparing 68 Gy and 78 Gy agreed to participate in an additional part of the trial that evaluated SF. Results: At baseline 28% of patients had erectile dysfunction (ED). After 1 year, 27% of the pretreatment potent patients had developed ED. After 2 years this percentage had increased to 36%. After 3 years it almost stabilized at 38%. Satisfaction with sexual life was significantly correlated with ED. After 2 years one third of the pre-treatment potent patients still had considerable to very much sexual desire and found sex (very) important. No significant differences were found between the two dose-arms. Potency aids were used on a regular base by 14% of the patients. Conclusion: By taking adjuvant hormonal therapy (HT), HT during follow-up and potency aids into account, we found a lower percentage of ED after 3D-CRT than reported in previous prospective studies. A large group of patients still had sexual desire, considered sex important and 14% used potency aids after 3D-CRT

  18. Strategies to evaluate the impact of rectal volume on prostate motion during three-dimensional conformal radiotherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Ana Paula Diniz Fortuna Poli

    2016-02-01

    Full Text Available Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037. A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045. Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.

  19. Prostate Bed Motion During Intensity-Modulated Radiotherapy Treatment

    International Nuclear Information System (INIS)

    Klayton, Tracy; Price, Robert; Buyyounouski, Mark K.; Sobczak, Mark; Greenberg, Richard; Li, Jinsheng; Keller, Lanea; Sopka, Dennis; Kutikov, Alexander; Horwitz, Eric M.

    2012-01-01

    Purpose: Conformal radiation therapy in the postprostatectomy setting requires accurate setup and localization of the prostatic fossa. In this series, we report prostate bed localization and motion characteristics, using data collected from implanted radiofrequency transponders. Methods and Materials: The Calypso four-dimensional localization system uses three implanted radiofrequency transponders for daily target localization and real-time tracking throughout a course of radiation therapy. We reviewed the localization and tracking reports for 20 patients who received ultrasonography-guided placement of Calypso transponders within the prostate bed prior to a course of intensity-modulated radiation therapy at Fox Chase Cancer Center. Results: At localization, prostate bed displacement relative to bony anatomy exceeded 5 mm in 9% of fractions in the anterior-posterior (A-P) direction and 21% of fractions in the superior-inferior (S-I) direction. The three-dimensional vector length from skin marks to Calypso alignment exceeded 1 cm in 24% of all 652 fractions with available setup data. During treatment, the target exceeded the 5-mm tracking limit for at least 30 sec in 11% of all fractions, generally in the A-P or S-I direction. In the A-P direction, target motion was twice as likely to move posteriorly, toward the rectum, than anteriorly. Fifteen percent of all treatments were interrupted for repositioning, and 70% of patients were repositioned at least once during their treatment course. Conclusion: Set-up errors and motion of the prostatic fossa during radiotherapy are nontrivial, leading to potential undertreatment of target and excess normal tissue toxicity if not taken into account during treatment planning. Localization and real-time tracking of the prostate bed via implanted Calypso transponders can be used to improve the accuracy of plan delivery.

  20. A comparison of swallowing dysfunction after three-dimensional conformal and intensity-modulated radiotherapy. A systematic review by the Italian Head and Neck Radiotherapy Study Group

    Energy Technology Data Exchange (ETDEWEB)

    Ursino, Stefano; Morganti, Riccardo; Cristaudo, Agostino; Paiar, Fabiola [University Hospital S. Chiara, Radiation Oncology, Pisa (Italy); D' Angelo, Elisa; Lohr, Frank [University Hospital, Radiation Oncology, Modena (Italy); Mazzola, Rosario [Sacro Cuore-Don Calabria Cancer Care Center, Radiation Oncology, Negrar-Verona (Italy); Merlotti, Anna; Russi, Elvio Grazioso [S. Croce e Carle Hospital, Radiation Oncology, Cuneo (Italy); Musio, Daniela [University Hospital La Sapienza, Radiation Oncology, Roma (Italy); Alterio, Daniela [European Institute of Oncology, Radiation Oncology, Advanced Radiotherapy Center, Milan (Italy); Bacigalupo, Almalina [AOU IRCCS San Martino - IST National Cancer Research Institute and University, Radiation Oncology, Genoa (Italy)

    2017-11-15

    Dysphagia is one of the most important treatment-related side effects in head and neck cancer (HNC), as it can lead to severe life-threating complications such as aspiration pneumonia and malnutrition. Intensity-modulated radiotherapy (IMRT) could reduce swallowing dysfunction by producing a concave dose distribution and reducing doses to the swallowing-related organs at risk (SWOARs). The aim of this study was to review the current literature in order to compare swallowing outcomes between IMRT and three-dimensional conformal radiotherapy (3DCRT). A search was conducted in the PubMed and Embase databases to identify studies on swallowing outcomes, both clinically and/or instrumentally assessed, after 3DCRT and IMRT. Dysphagia-specific quality of life and objective instrumental data are summarized and discussed. A total of 262 papers were retrieved from the searched databases. An additional 23 papers were retrieved by hand-searching the reference lists. Ultimately, 22 papers were identified which discussed swallowing outcomes after 3DCRT and IMRT for HNC. No outcomes from randomized trials were identified. Despite several methodological limitations, reports from the current literature seem to suggest better swallowing outcomes with IMRT compared to 3DCRT. Further improvements are likely to result from the increased use of IMRT plans optimized for SWOAR sparing. (orig.) [German] Dysphagie ist eine der wichtigsten Nebenwirkungen bei der Behandlung von Kopf-Hals-Tumoren (HNC), da sie zu lebensbedrohlichen Komplikationen wie Aspirationspneumonien und Mangelernaehrung fuehren kann. Durch Erzeugung konkaver Dosisverteilungen und durch die Reduzierung der Dosis an schluckrelevanten Strukturen (SWOAR) kann die IMRT Schluckstoerungen moeglicherweise vermindern. Ziel dieser Studie war es, die gegenwaertige Literaturlage hinsichtlich der Schluckfunktion nach IMRT und konformaler dreidimensionaler Strahlentherapie (3DCRT) systematisch zu ueberpruefen. Studien, die die

  1. Dosimetric inter-institutional comparison in European radiotherapy centres: Results of IAEA supported treatment planning system audit.

    Science.gov (United States)

    Gershkevitsh, Eduard; Pesznyak, Csilla; Petrovic, Borislava; Grezdo, Joseph; Chelminski, Krzysztof; do Carmo Lopes, Maria; Izewska, Joanna; Van Dyk, Jacob

    2014-05-01

    One of the newer audit modalities operated by the International Atomic Energy Agency (IAEA) involves audits of treatment planning systems (TPS) in radiotherapy. The main focus of the audit is the dosimetry verification of the delivery of a radiation treatment plan for three-dimensional (3D) conformal radiotherapy using high energy photon beams. The audit has been carried out in eight European countries - Estonia, Hungary, Latvia, Lithuania, Serbia, Slovakia, Poland and Portugal. The corresponding results are presented. The TPS audit reviews the dosimetry, treatment planning and radiotherapy delivery processes using the 'end-to-end' approach, i.e. following the pathway similar to that of the patient, through imaging, treatment planning and dose delivery. The audit is implemented at the national level with IAEA assistance. The national counterparts conduct the TPS audit at local radiotherapy centres through on-site visits. TPS calculated doses are compared with ion chamber measurements performed in an anthropomorphic phantom for eight test cases per algorithm/beam. A set of pre-defined agreement criteria is used to analyse the performance of TPSs. TPS audit was carried out in 60 radiotherapy centres. In total, 190 data sets (combination of algorithm and beam quality) have been collected and reviewed. Dosimetry problems requiring interventions were discovered in about 10% of datasets. In addition, suboptimal beam modelling in TPSs was discovered in a number of cases. The TPS audit project using the IAEA methodology has verified the treatment planning system calculations for 3D conformal radiotherapy in a group of radiotherapy centres in Europe. It contributed to achieving better understanding of the performance of TPSs and helped to resolve issues related to imaging, dosimetry and treatment planning.

  2. Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique

    Science.gov (United States)

    Mani, Karthick Raj; Basu, Saumen; Bhuiyan, Md Anisuzzaman; Ahmed, Sharif; Sumon, Mostafa Aziz; Haque, Kh Anamul; Sengupta, Ashim Kumar; Un Nabi, Md Rashid; Das, K. J. Maria

    2017-06-01

    Objective: The purpose of this study is to demonstrate the synchronous bilateral breast irradiation radiotherapy technique using a single isocenter. Materials and Methods: Six patients of synchronous bilateral breast were treated with single isocenter technique from February 2011 to June 2016. All the patients underwent a CT-simulation using appropriate positioning device. Target volumes and critical structures like heart, lung, esophagus, thyroid, etc., were delineated slice by slice in the CT data. An isocenter was placed above the sternum on the skin and both medial tangential and lateral tangential of the breast / chest wall were created using asymmetrical jaws to avoid the beam divergence through the lung and heart. The field weighting were adjusted manually to obtain a homogenous dose distribution. The planning objectives were to deliver uniform doses around the target and keep the doses to the organ at risk within the permissible limit. The beam energy of 6 MV or combination of 6 MV and 15 MV photons were used in the tangential fields according to the tangential separation. Boluses were used for all the mastectomy patients to increase the doses on the chest wall. In addition to that enhanced dynamic wedge and field in field technique were also used to obtain a homogenous distribution around the target volume and reduce the hot spots. The isocenter was just kept on the skin, such that the beam junctions will be overlapped only on the air just above the sternum. Acute toxicity during the treatment and late toxicity were recorded during the patient's follow-up. Results: During the radiotherapy treatment follow-up there were no acute skin reactions in the field junctions, but one patient had grade 1 esophagitis and two patients had grade 2 skin reactions in the chest wall. With a median follow-up of 38.5 months (range: 8 - 49 months), no patients had a local recurrence, but one patients with triple negative disease had a distant metastases in brain and died

  3. Late Outcomes Following Hypofractionated Conformal Radiotherapy vs. Standard Fractionation for Localized Prostate Cancer: A Nonrandomized Contemporary Comparison

    International Nuclear Information System (INIS)

    Leborgne, Felix; Fowler, Jack

    2009-01-01

    Purpose: To study retrospectively late complications and biochemical control in patients treated with three-dimensional conformal external-beam radiotherapy for localized prostate cancer administered using hypofractionation vs. a standard fractionation regimen. The hypofractionation regimen (Hypo) was designed to avoid more late rectal reactions and to be done in half as many treatment sessions. Methods and Materials: Eighty-nine nonrandomized patients chose Hypo delivered in 20 fractions of 3 Gy (n = 52) or 3.15 Gy (n = 37) for a median overall treatment time of 33 days. One hundred thirty comparable patients were contemporaneously treated with standard fractionation to a median dose of 78 Gy delivered over 55 days. The median follow-up time was 49 months (range, 24-73 months). Results: The 5-year actuarial biochemical control rates were 96%, 84%, and 85% for low-, medium-, and high-risk disease in the Hypo group, respectively. The respective rates in the standard fractionation group were 98%, 84%, and 87%, with no statistical difference between the two groups. The rate of rectal Grade 2-4 complications was 5.5% in both treatment groups and of urinary Grade 2-4 complications was 5.6% in the Hypo and 3% in the standard group (p = 0.36). Similarly, there were no statistical differences in the rate of late complications between patients treated with 3 Gy/fraction vs. 3.15 Gy/fraction. Conclusions: Our preliminary results showed that the Hypo regimen is feasible and does not reduce biochemical control compared with standard fractionation. The incidence of late complications was not increased when the tumor normalized total doses at 2Gy/fraction was increased from 77.1 to 83.7 Gy in patients treated with either 3 or 3.15 Gy/fraction in the Hypo group, respectively.

  4. Associations between nutritional status, weight loss, radiotherapy treatment toxicity and treatment outcomes in gastrointestinal cancer patients.

    Science.gov (United States)

    Hill, Amanda; Kiss, Nicole; Hodgson, Belinda; Crowe, Timothy C; Walsh, Adam D

    2011-02-01

    Patients with gastrointestinal cancers are susceptible to nutritional deterioration which may be compounded by radiotherapy treatment toxicities. This study aimed to determine whether nutritional status at radiotherapy commencement or changes in nutritional status throughout radiotherapy were associated with treatment toxicity and outcomes in gastrointestinal cancer patients. Seventy-three gastrointestinal cancer patients receiving curative radiotherapy underwent medical record audits assessing body weight, radiotherapy toxicity, unplanned treatment breaks or hospital admissions and completion of prescribed treatment/s. Nutritional status was assessed in a subset of patients (n = 11) using the Patient-Generated Subjective Global Assessment tool. Seventy-five percent of patients lost weight throughout radiotherapy. Weight loss was significantly greater in patients experiencing unplanned radiotherapy breaks (-3.1% vs -1.6%, p nutritional status during radiotherapy (as measured by weight loss) may be associated with poorer short-term treatment outcomes in gastrointestinal cancer patients. Patient numbers were too small to definitively determine the effect of nutritional status at radiotherapy commencement or changes in nutritional status throughout radiotherapy (defined by PG-SGA) on treatment outcomes. Further research is required to investigate this in larger, longer-term studies. Copyright © 2010. Published by Elsevier Ltd.

  5. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    International Nuclear Information System (INIS)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G.

    2002-01-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7±17.1 and 40.4±16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7±4.8 ccm for 3D-HOF and 10.7±12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma

  6. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    Energy Technology Data Exchange (ETDEWEB)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G. [National Research Inst. for Radiobiology and Radiohygiene, Budapest (Hungary)

    2002-04-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7{+-}17.1 and 40.4{+-}16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7{+-}4.8 ccm for 3D-HOF and 10.7{+-}12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma.

  7. Outcomes After Intensity-Modulated Versus Conformal Radiotherapy in Older Men With Nonmetastatic Prostate Cancer

    International Nuclear Information System (INIS)

    Bekelman, Justin E.; Mitra, Nandita; Efstathiou, Jason; Liao Kaijun; Sunderland, Robert; Yeboa, Deborah N.; Armstrong, Katrina

    2011-01-01

    Purpose: There is little evidence comparing complications after intensity-modulated (IMRT) vs. three-dimensional conformal radiotherapy (CRT) for prostate cancer. The study objective was to test the hypothesis that IMRT, compared with CRT, is associated with a reduction in bowel, urinary, and erectile complications in elderly men with nonmetastatic prostate cancer. Methods and Materials: We undertook an observational cohort study using registry and administrative claims data from the SEER-Medicare database. We identified men aged 65 years or older diagnosed with nonmetastatic prostate cancer in the United States between 2002 and 2004 who received IMRT (n = 5,845) or CRT (n = 6,753). The primary outcome was a composite measure of bowel complications. Secondary outcomes were composite measures of urinary and erectile complications. We also examined specific subsets of bowel (proctitis/hemorrhage) and urinary (cystitis/hematuria) events within the composite complication measures. Results: IMRT was associated with reductions in composite bowel complications (24-month cumulative incidence 18.8% vs. 22.5%; hazard ratio [HR] 0.86; 95% confidence interval [CI], 0.79–0.93) and proctitis/hemorrhage (HR 0.78; 95% CI, 0.64–0.95). IMRT was not associated with rates of composite urinary complications (HR 0.93; 95% CI, 0.83–1.04) or cystitis/hematuria (HR 0.94; 95% CI, 0.83–1.07). The incidence of erectile complications involving invasive procedures was low and did not differ significantly between groups, although IMRT was associated with an increase in new diagnoses of impotence (HR 1.27, 95% CI, 1.14–1.42). Conclusion: IMRT is associated with a small reduction in composite bowel complications and proctitis/hemorrhage compared with CRT in elderly men with nonmetastatic prostate cancer.

  8. Patients with hip prosthesis: radiotherapy treatment planning considerations

    International Nuclear Information System (INIS)

    Ganesh, K.M.; Supe, Sanjay S.

    2000-01-01

    The number of patients with hip prosthesis undergoing radiotherapy for pelvic cancer worldwide is increasing. This might be of importance depending on the materials in the prosthesis and whether any of the treatment fields are involved in the prosthesis. Radiotherapy planning involving the pelvic region of patients having total hip prosthesis has been found to be difficult due to the effect of the prosthesis on the dose distribution. This review is intended to project dosimetric considerations and possible solutions to this uncommon problem

  9. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Jackie; Suttie, Clare; Bromley, Regina; Morgia, Marita; Lamoury, Gillian [Department of Radiation Oncology, Royal North Shore Hospital, St Leonards, New South Wales (Australia)

    2015-09-15

    We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.

  10. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    International Nuclear Information System (INIS)

    Yim, Jackie; Suttie, Clare; Bromley, Regina; Morgia, Marita; Lamoury, Gillian

    2015-01-01

    We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D 105% and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT

  11. Automated system for review of radiotherapy treatment sheets

    International Nuclear Information System (INIS)

    Collado Chamorro, P.; Sanz Freire, C. J.; Vazquez Galinanes, A.; Diaz Pascual, V.; Gomez amez, J.; Martinez Sanchez, S.; Ossola Lentati, G. A.

    2011-01-01

    In many modern radiotherapy services begins to leaf treatment implemented in electronic form. In our department has developed an automated reporting system, that check the following parameters: treatment completed correctly, number of sessions and cumulative dose administered. Likewise treatments are verified in the allocated separate unit, and over-writing table parameters.

  12. Independent dose calculation of the Tps Iplan in radiotherapy conformed with MLC

    International Nuclear Information System (INIS)

    Adrada, A.; Tello, Z.; Medina, L.; Garrigo, E.; Venencia, D.

    2014-08-01

    The systems utilization of independent dose calculation in three dimensional-Conformal Radiation Therapy (3D-Crt) treatments allows a direct verification of the treatments times. The utilization of these systems allows diminishing the probability of errors occurrence generated by the treatment planning system (Tps), allowing a detailed analysis of the dose to delivering and review of the normalization point (Np) or prescription. The independent dose calculation is realized across the knowledge of dosimetric parameters of the treatment machine and particular characteristics of every individual field. The aim of this work is develops a calculation system of punctual doses for isocentric fields conformed with multi-leaf collimation systems (MLC), where the dose calculation is in conformity with the suggested ones by ICRU Report No. 42, 1987. Calculation software was realized in C ++ under a free platform of programming (Code::Blocks). The system uses files in format Rtp, exported from the Tps to systems of record and verification (Lantis). This file contains detailed information of the dose, Um, position of the MLC sheets and collimators for every field of treatment. The size of equivalent field is obtained from the positions of every sheet; the effective depth of calculation can be introduced from the dosimetric report of the Tps or automatically from the DFS of the field. The 3D coordinates of the isocenter and the Np for the treatment plan must be introduced manually. From this information the system looks the dosimetric parameters and calculates the Um. The calculations were realized in two accelerators a NOVALIS Tx (Varian) with 120 sheets of high definition (hd-MLC) and a PRIMUS Optifocus (Siemens) with 82 sheets. 705 patients were analyzed for a total of 1082, in plans made for both equipment s, the average uncertainty with regard to the calculation of the Tps is-0.43% ± 2.42% in a range between [-7.90 %, 7.50 %]. The major uncertainty was in Np near of the

  13. Quality assurance of a conformal treatment technique

    Energy Technology Data Exchange (ETDEWEB)

    Kroes, A P.G.; Bruinvis, I A.D.; Lanson, J H; Uiterwaal, G J [Nederlands Kanker Inst. ` Antoni van Leeuwenhoekhuis` , Amsterdam (Netherlands)

    1995-12-01

    For a parotid gland irradiation technique with a pair of oblique wedged photon beams the target coverage near the surface was investigated. The planning target volume extends to 5 millimetres under the skin; a minimum target dose of 95% is required when the dose at the centre is set to 100%. The treatment technique was simulated on a water phantom with a beam of 45 degree gantry angle, 55 degree wedge, 8 x 10 cm{sup 2} field size and the isocentre at 2 cm depth. Beam energies of 4, 6 and 8 MV were used. The dose distributions were measured in two orthogonal planes through the isocentre perpendicular to the water surface with p-type silicon diodes along lines through the isocentre every 45 degrees. Dose distributions were calculated in these planes with our 3-D planning system (U-Mplan, University of Michigan planning system), with model parameters are fitted to depth dose curves and profiles of open and wedged normally incident beams. The location of the 95% isodose was determined in five points near the surface. For 4, 6 and 8 MV the depths of the 95% isodose were 6.0, 10.3 and 11.0 mm, respectively. The depths of the 95% points of single normally incident open fields were 6.0, 9.0 and 11.5 mm, respectively. The treatment planning system (TPS) calculated the 95% isodose for the parotid technique at 5.5, 7.3 and 11.5 mm depths, for 4, 6 and 8 MV, respectively. Thus for 6 MV the 95% was 3 mm deeper than calculated by the TPS; 2 mm were caused by the inaccuracy of the open field depth dose curve fit in the build-up region. The depth near the surface of the 95% isodose for this treatment technique can be estimated from single open field depth dose curves with acceptable accuracy. This result is not obvious because the effects of the wedge and oblique incidence on the dose distribution are also involved. The TPS performed well for the 4 and 8 MV beams, but for treatments with 6 MV target under dosage could have remained undetected. (Abstract Truncated)

  14. Modern possibilities of radiotherapy in the complex and single treatment of panaris

    International Nuclear Information System (INIS)

    Kolipiliev, V.; Momchev, M.

    1979-01-01

    Results are reported of the treatment of 282 patients with different forms of panaris: 39 per cent received radiotherapy alone, in the remaining radiotherapy was combined with surgical management, antibiotics and local treatment. Two different radiotherapy schemes were attempted: 49% of the patients received rather high single (50-80 rad) and total (300-600 rad) doses in the local site at a regimen of superficial (100 kV, 4 mm Al) or deep (180-200 kV, 0.5-1 mm Cu) roentgentherapy, with size of field 4/4 cm or 4/6 cm and 30-40 cm distance. In the remaining 51% of patients radiotherapy was characterized by dynamic fractionation and longer duration of procedures with significantly lower single (30-40 rad) and total (160-320 rad) doses. In recent years the second scheme has been preferred and has gain wide acceptance. Irradiation dose and rate invariably conformed to the type of inflammatory process. Patients with panaritium paronychium and panaritium subcutaneum admitted for treatment in the first few days of development of the digital infection required only several procedures on alternate days to achieve complete cure in a week. In the event of pus collection, 1 or 2 irradiation procedures accelerated abscess formation; this was followed by surgical intervention with postoperative radiotherapy to hasten the granulation process. Treatment of bone-and-joint forms of panaris was complex with initially higher single doses, followed by lower ones, applied up to twice weekly. The following advantages of the method are pointed out: shortening of treatment, respectively of the disability period; easy to perform, painless and practically innocuous manipulation. Complete cure could not be achieved only in advanced, torpid cases. (A.B.)

  15. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    1996-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing

  16. Poster - 21: Verification of Monitor Unit Calculations for Breast Field-In-Field Three-Dimensional Conformal Radiotherapy Plans

    International Nuclear Information System (INIS)

    Kosztyla, Robert; Pierce, Greg; Ploquin, Nicolas; Roumeliotis, Michael; Schinkel, Colleen

    2016-01-01

    Purpose: To determine the source of systematic monitor unit (MU) calculation discrepancies between RadCalc and Eclipse treatment planning software for three-dimensional conformal radiotherapy field-in-field breast treatments. Methods: Data were reviewed for 28 patients treated with a field-in-field breast technique with MU calculations from RadCalc that were larger than MU calculations from Eclipse for at least one field. The distance of the calculation point from the jaws was measured in each field’s beam’s-eye-view and compared with the percentage difference in MU (%ΔMU) between RadCalc and Eclipse. 10×10, 17×13 and 20×20 cm 2 beam profiles were measured using the Profiler 2 diode array for 6-MV photon beams and compared with profiles calculated with Eclipse and RadCalc using a gamma analysis (3%, 3 mm). Results: The mean %ΔMU was 1.3%±0.3%. There was a statistically-significant correlation between %ΔMU and the distance of the calculation point from the Y jaw (r=−0.43, p<0.001). RadCalc profiles differed from measured profiles, especially near the jaws. The gamma pass rate for 6-MV fields of 17×13 cm 2 field size was 95%±1% for Eclipse-generated profiles and 53%±20% for RadCalc-generated profiles (p=0.01). Conclusions: Calculations using RadCalc for field-in-field breast plans resulted in MUs that were larger than expected from previous clinical experience with wedged plans with calculation points far from the jaws due to the position of the calculation point near the jaws in the beam’s-eye-view of each field.

  17. Poster - 21: Verification of Monitor Unit Calculations for Breast Field-In-Field Three-Dimensional Conformal Radiotherapy Plans

    Energy Technology Data Exchange (ETDEWEB)

    Kosztyla, Robert; Pierce, Greg; Ploquin, Nicolas; Roumeliotis, Michael; Schinkel, Colleen [Tom Baker Cancer Centre, Calgary, AB, Tom Baker Cancer Centre, Tom Baker Cancer Centre, Tom Baker Cancer Centre, Calgary, AB, Tom Baker Cancer Centre, Calgary, AB (Canada)

    2016-08-15

    Purpose: To determine the source of systematic monitor unit (MU) calculation discrepancies between RadCalc and Eclipse treatment planning software for three-dimensional conformal radiotherapy field-in-field breast treatments. Methods: Data were reviewed for 28 patients treated with a field-in-field breast technique with MU calculations from RadCalc that were larger than MU calculations from Eclipse for at least one field. The distance of the calculation point from the jaws was measured in each field’s beam’s-eye-view and compared with the percentage difference in MU (%ΔMU) between RadCalc and Eclipse. 10×10, 17×13 and 20×20 cm{sup 2} beam profiles were measured using the Profiler 2 diode array for 6-MV photon beams and compared with profiles calculated with Eclipse and RadCalc using a gamma analysis (3%, 3 mm). Results: The mean %ΔMU was 1.3%±0.3%. There was a statistically-significant correlation between %ΔMU and the distance of the calculation point from the Y jaw (r=−0.43, p<0.001). RadCalc profiles differed from measured profiles, especially near the jaws. The gamma pass rate for 6-MV fields of 17×13 cm{sup 2} field size was 95%±1% for Eclipse-generated profiles and 53%±20% for RadCalc-generated profiles (p=0.01). Conclusions: Calculations using RadCalc for field-in-field breast plans resulted in MUs that were larger than expected from previous clinical experience with wedged plans with calculation points far from the jaws due to the position of the calculation point near the jaws in the beam’s-eye-view of each field.

  18. Combination of Transarterial Chemoembolization and Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma With Inferior Vena Cava Tumor Thrombus

    International Nuclear Information System (INIS)

    Koo, Ja Eun; Kim, Jong Hoon; Lim, Young-Suk

    2010-01-01

    Purpose: To evaluate the effects of transarterial chemoembolization (TACE) and three-dimensional conformal radiotherapy (CRT) in patients with hepatocellular carcinoma (HCC) and inferior vena cava tumor thrombus (IVCTT). Methods and Materials: A total of 42 consecutive patients who underwent TACE and CRT (TACE+CRT group) for the treatment of HCC with IVCTT were prospectively enrolled from July 2004 to October 2006. As historical controls, 29 HCC patients with IVCTT who received TACE alone (TACE group) between July 2003 and June 2004 were included. CRT was designed to target only the IVCTT and to deliver a median total dose of 45 Gy (range, 28-50 Gy). Results: Most baseline characteristics of the two groups were similar (p > 0.05). The response and progression-free rates of IVCTT were significantly higher in the TACE+CRT group than in the TACE group (42.9% and 71.4% vs. 13.8% and 37.9%, respectively; p < 0.01 for both rates). Overall, patient survival was significantly higher in the TACE+CRT group than in the TACE group (p < 0.01), with a median survival time of 11.7 months and 4.7 months, respectively. Treatment with TACE+CRT (hazard ratio [HR] = 0.38; 95% confidence interval [CI], 0.20-0.71), progression of IVCTT (HR = 4.05; 95% CI, 2.00-8.21), Child-Pugh class B (HR = 3.44; 95% CI, 1.79-6.61), and portal vein invasion (HR = 2.31; 95% CI, 1.19-4.50) were identified as independent predictors of mortality by multivariable analysis. Conclusions: The combination of TACE and CRT is more effective in the control of IVCTT associated with HCC and improves patient survival compared with TACE alone.

  19. Prone Hypofractionated Whole-Breast Radiotherapy Without a Boost to the Tumor Bed: Comparable Toxicity of IMRT Versus a 3D Conformal Technique

    Energy Technology Data Exchange (ETDEWEB)

    Hardee, Matthew E.; Raza, Shahzad; Becker, Stewart J.; Jozsef, Gabor; Lymberis, Stella C. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Hochman, Tsivia; Goldberg, Judith D. [Division of Biostatistics, New York University School of Medicine, New York, NY (United States); DeWyngaert, Keith J. [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States); Formenti, Silvia C., E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, NY (United States)

    2012-03-01

    Purpose: We report a comparison of the dosimetry and toxicity of three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT) among patients treated in the prone position with the same fractionation and target of the hypofractionation arm of the Canadian/Whelan trial. Methods and Materials: An institutional review board-approved protocol identified a consecutive series of early-stage breast cancer patients treated according to the Canadian hypofractionation regimen but in the prone position. Patients underwent IMRT treatment planning and treatment if the insurance carrier approved reimbursement for IMRT; in case of refusal, a 3D-CRT plan was used. A comparison of the dosimetric and toxicity outcomes during the acute, subacute, and long-term follow-up of the two treatment groups is reported. Results: We included 97 consecutive patients with 100 treatment plans in this study (3 patients with bilateral breast cancer); 40 patients were treated with 3D-CRT and 57 with IMRT. IMRT significantly reduced the maximum dose (Dmax median, 109.96% for 3D-CRT vs. 107.28% for IMRT; p < 0.0001, Wilcoxon test) and improved median dose homogeneity (median, 1.15 for 3D-CRT vs. 1.05 for IMRT; p < 0.0001, Wilcoxon test) when compared with 3D-CRT. Acute toxicity consisted primarily of Grade 1 to 2 dermatitis and occurred in 92% of patients. Grade 2 dermatitis occurred in 13% of patients in the 3D-CRT group and 2% in the IMRT group. IMRT moderately decreased rates of acute pruritus (p = 0.03, chi-square test) and Grade 2 to 3 subacute hyperpigmentation (p = 0.01, Fisher exact test). With a minimum of 6 months' follow-up, the treatment was similarly well tolerated in either group, including among women with large breast volumes. Conclusion: Hypofractionated breast radiotherapy is well tolerated when treating patients in the prone position, even among those with large breast volumes. Breast IMRT significantly improves dosimetry but yields only a modest

  20. Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

    Energy Technology Data Exchange (ETDEWEB)

    Komisopoulos, Georgios [Department of Medical Physics, Medical School, University of Patras, Patras (Greece); Mavroidis, Panayiotis, E-mail: mavroidis@uthscsa.edu [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden); Rodriguez, Salvador; Stathakis, Sotirios; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States); Nikiforidis, Georgios C.; Sakellaropoulos, Georgios C. [Department of Medical Physics, Medical School, University of Patras, Patras (Greece)

    2014-01-01

    The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the

  1. Treatment results of radiotherapy for medically inoperable stage I/II non-small cell lung cancer

    International Nuclear Information System (INIS)

    Zhang Li; Wang Lvhua; Zhang Hongxing; Chen Dongfu; Xiao Zefen; Wang Mei; Feng Qinfu; Liang Jun; Zhou Zongmei; Ou Guangfei; Lv Jima; Yin Weibo

    2008-01-01

    Objective: To retrospectively analyze treatment results of radiotherapy for medically inoperable stage I/II non-small cell lung cancer. Methods: Between Jan. 2000 and Dec. 2005, fifty-eight such patients were enrolled into the database analysis, including 37 with clinical stage I and 21 with stage II disease. Fifty patients received radiotherapy alone and eight with radiotherapy and chemotherapy. Forty- three patients were treated with 3-D conformal radiotherapy (3D-CRT) and 15 with conventional radiotherapy. Results: The 1-, 2- and 3-year overall survival rates were 85%, 54% and 30%, and the median survival time was 26.2 months for the whole group. The corresponding figures were 88%, 60%, 36% and 30.8 months for cancer-specific survival; 84%, 64%, 31% and 30.8 months for Stage I disease; 81%, 47%, 28% and 18.8 months for Stage II disease; 95%, 57%, 33% and 30.8 months for 3D-CRT group and 53%, 44%, 24% and 15.3 months for conventional radiotherapy group. By logrank test, tumor volume, pneumonitis of Grade II or higher and weight loss more than 5% showed statistically significant impact on overall survival. Tumor volume was the only independent prognostic factor in Cox multivariable regression. Pneumonitis and esophagitis of Grade II or higher were 16% and 2%, respectively. Age and lung function before treatment had a significant relationship with pneumonitis. Failure included the local recurrence (33%) and distant metastasis (21%). There was no difference between the treatment modalities and failure sites. Conclusions: For medically inoperable early stage non-small cell lung cancer patients, tumor volume is the most important prognostic factor for overall survival. The conformal radiotherapy marginally improves the survival. The age and pulmonary function are related to the incidence of treatment induced pneumonitis. (authors)

  2. Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

    International Nuclear Information System (INIS)

    Koontz, Bridget F.; Das, Shiva; Temple, Kathy; Bynum, Sigrun; Catalano, Suzanne; Koontz, Jason I.; Montana, Gustavo S.; Oleson, James R.

    2009-01-01

    Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

  3. Dosimetric and radiobiologic comparison of 3D conformal versus intensity modulated planning techniques for prostate bed radiotherapy.

    Science.gov (United States)

    Koontz, Bridget F; Das, Shiva; Temple, Kathy; Bynum, Sigrun; Catalano, Suzanne; Koontz, Jason I; Montana, Gustavo S; Oleson, James R

    2009-01-01

    Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

  4. Automatization of the radiotherapy treatment at Nuclear Medicine Center

    International Nuclear Information System (INIS)

    Anjak, O.; Al'Bahra, E.; Kharita, M.H.

    2007-01-01

    NMC Program for Automatization of the radiotherapy treatment at Nuclear Medicine Center. The program NMC written in Delphi 6. This program can be run under Windows XP as single and multi users. Program makes all necessary and required calculations for treatment time for patient who is under radiotherapy treatment in Nuclear Medicine Center by using Co-60 units. Also this program is perform statistical study for patients according to tumor type, Syrian City, sex, and age. Data is stored on disk files and then whenever should be displayed. Statistical data is displayed on the screen or printed in reports. (author)

  5. 3-D conformal radiotherapy of localized prostate cancer: A subgroup analysis of rectoscopic findings prior to radiotherapy and acute/late rectal side effects

    International Nuclear Information System (INIS)

    Goldner, Gregor; Zimmermann, Frank; Feldmann, Horst; Glocker, Stefan; Wachter-Gerstner, Natascha; Geinitz, Hans; Becker, Gerd; Poetzi, Regina; Wambersie, Andre; Bamberg, Michael; Molls, Michael; Wachter, Stefan; Poetter, Richard

    2006-01-01

    Background and purpose: To identify endoscopic pathological findings prior to radiotherapy and a possible correlation with acute or chronic rectal side effects after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Patients and methods: Between 03/99 and 07/02, a total of 298 patients, who consented in a voluntary rectoscopy prior to radiotherapy were included into the analysis. Patients were treated with a total dose of either 70 or 74 Gy. Pathological rectoscopic findings like hemorrhoids, polyps or diverticula were documented. Acute and late rectal side effects were scored using the EORTC/RTOG score. Results: The most frequent pathological endosopic findings were hemorrhoids (35%), polyps (24%) and diverticula (13%). Rectal toxicity was mostly low to moderate. Grade 0/1 cumulative acute and late rectal side effects were 82 and 84%, grade 2 were 18 and 17%, respectively. We could not identify any correlation between preexisting pathological findings and rectal side effects by statistical analysis. Conclusions: There is no evidence that prostate cancer patients presenting with endoscopic verified pathological findings in the rectal mucosa at diagnosis are at an increased risk to develop rectal side effects when treated with 3D-CRT of the prostatic region

  6. Chondrosarcoma of the larynx: treatment with radiotherapy

    International Nuclear Information System (INIS)

    Dailiana, T.; Thanos, L.; Papathanasiou, M.; Alexopoulou, E.; Papaioannou, G.; Kelekis, D.A.; Nomikos, P.; Kapranos, N.

    2002-01-01

    The case of a 50-year-old man with chondrosarcoma of the larynx treated with radiotherapy is reported. The patient presented with hoarseness and dyspnea. He underwent computed tomography (CT), which demonstrated a soft tissue mass of the larynx. Direct laryngoscopy with biopsy established the diagnosis of chondrosarcoma. Although experience with radiotherapy in these cases has been lacking in the literature, it was considered and eventually used, as radical surgery would result in severe cosmetic and functional impairment. Radiation therapy alone resulted in long-term remission of the tumour for more than 3 years. The patient has been followed up using CT and direct laryngoscopy for early detection of recurrence or metastases. (orig.)

  7. Radiotherapy in the treatment of lymphomas

    International Nuclear Information System (INIS)

    King, H.S.

    1987-01-01

    The majority of lymphomas are sensitive and respond well to relatively low doses of irradiation. Careful staging of Hodgkin's disease patients selects the patients who can be cured with irradiation alone, and the combination of chemotherapy and irradiation may result in cure of complete remission in all types of lymphoma. In non-Hodgkin's disease and late stage Hodgkin's disease, radiotherapy is a very useful modality for palliating bulky disease, and treating bone infliltration or other painful areas

  8. Hepatitis B Virus Reactivation After Three-Dimensional Conformal Radiotherapy in Patients With Hepatitis B Virus-Related Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Kim, Ji Hoon; Park, Joong-Won; Kim, Tae Hyun; Koh, Dong Wook; Lee, Woo Jin; Kim, Chang-Min

    2007-01-01

    Purpose: To investigate whether three-dimensional conformal radiotherapy (3D-CRT) influences hepatitis B virus (HBV) reactivation and chronic hepatitis B (CHB) exacerbation in patients with HBV-related hepatocellular carcinoma (HCC). Methods and Materials: Of the 48 HCC patients with HBV who underwent 3D-CRT to the liver, 16 underwent lamivudine therapy before and during 3D-CRT (Group 1) and 32 did not receive antiviral therapy before 3D-CRT (Group 2). To analyze spontaneous HBV reactivation, we included a control group of 43 HCC patients who did not receive any specific treatment for HCC or CHB. Results: The cumulative rate of radiation-induced liver disease for Groups 1 and 2 was 12.5% (2 of 16) and 21.8% (7 of 32), respectively (p > 0.05). The cumulative rate of HBV reactivation was significantly greater in Group 2 (21.8%, 7 of 32) than in Group 1 (0%, 0/16) or the control group (2.3%, 1 of 43; p 0.05 each). The CHB exacerbations in the 4 Group 2 patients had radiation-induced liver disease features but were differentiated by serum HBV DNA changes. Two of these patients required antiviral therapy and effectively recovered with lamivudine therapy. Conclusions: In patients with HBV-related HCC undergoing 3D-CRT, HBV reactivation and consequent CHB exacerbation should be considered in the differential diagnosis of radiation-induced liver disease, and antiviral therapy might be considered for the prevention of liver function deterioration after RT

  9. A phase II study of localized prostate cancer treated to 75.6 Gy with 3D conformal radiotherapy

    International Nuclear Information System (INIS)

    Nichol, Alan; Chung, Peter; Lockwood, Gina; Rosewall, Tara; Divanbiegi, Lorella; Sweet, Joan; Toi, Ants; Bayley, Andrew; Bristow, Rob; Crook, Juanita; Gospodarowicz, Mary; McLean, Michael; Milosevic, Michael; Warde, Padraig; Catton, Charles

    2005-01-01

    Background and purpose: To prospectively evaluate toxicity, biochemical failure-free survival (bFFS) and biopsy-proven local control for prostate cancer patients treated with 75.6 Gy in 42 fractions using 6-field conformal radiotherapy to prostate alone. Patients and methods: From 1997 to 1999, 140 patients with T1-2NxM0, Gleason score ≤8, and PSA ≤20 ng/ml prostate cancer were assessed using Radiation Therapy Oncology Group acute and late toxicity scores. bFFS was determined for 120 patients treated without hormones. Post-treatment prostate biopsies were performed at a median of 3 years and a late toxicity questionnaire was administered at a median of 5 years. Results: Clinically important acute toxicities were gastrointestinal (GI) grade 2: 22% and 3: 0%, and genitourinary (GU) grade 2: 24% and 3: 2%. Late physician-assessed toxicities were GI ≥grade 2: 2%, and GU ≥grade 2: 1%. The 3-year bFFS of patients failure-free before biopsy was 93% (95% CI: 83-100) from a negative biopsy and 22% (95% CI: 0-56) from a positive biopsy (P=0.001). Patients reported significantly more late toxicity than physicians (GI: P=0.003, GU: P<0.001). At 5.0 years median follow-up, cause-specific survival was 98% (95% CI: 96-100), overall survival was 91% (95% CI: 86-97), and bFFS was 55% (95% CI: 45-64). Conclusions: 75.6 Gy caused modest levels of acute and late toxicity. Three-year biopsies predicted subsequent biochemical outcome

  10. Dosimetric Feasibility of Hypofractionated Proton Radiotherapy for Neoadjuvant Pancreatic Cancer Treatment

    International Nuclear Information System (INIS)

    Kozak, Kevin R.; Kachnic, Lisa A.; Adams, Judith C; Crowley, Elizabeth M.; Alexander, Brian M.; Mamon, Harvey J.; Fernandez-Del Castillo, Carlos; Ryan, David P.; DeLaney, Thomas F.; Hong, Theodore S.

    2007-01-01

    Purpose: To evaluate tumor and normal tissue dosimetry of a 5 cobalt gray equivalent (CGE) x 5 fraction proton radiotherapy schedule, before initiating a clinical trial of neoadjuvant, short-course proton radiotherapy for pancreatic adenocarcinoma. Methods and Materials: The first 9 pancreatic cancer patients treated with neoadjuvant intensity-modulated radiotherapy (1.8 Gy x 28) at the Massachusetts General Hospital had treatment plans generated using a 5 CGE x 5 fraction proton regimen. To facilitate dosimetric comparisons, clinical target volumes and normal tissue volumes were held constant. Plans were optimized for target volume coverage and normal tissue sparing. Results: Hypofractionated proton and conventionally fractionated intensity-modulated radiotherapy plans both provided acceptable target volume coverage and dose homogeneity. Improved dose conformality provided by the hypofractionated proton regimen resulted in significant sparing of kidneys, liver, and small bowel, evidenced by significant reductions in the mean doses, expressed as percentage prescribed dose, to these structures. Kidney and liver sparing was most evident in low-dose regions (≤20% prescribed dose for both kidneys and ≤60% prescribed dose for liver). Improvements in small-bowel dosimetry were observed in high- and low-dose regions. Mean stomach and duodenum doses, expressed as percentage prescribed dose, were similar for the two techniques. Conclusions: A proton radiotherapy schedule consisting of 5 fractions of 5 CGE as part of neoadjuvant therapy for adenocarcinoma of the pancreas seems dosimetrically feasible, providing excellent target volume coverage, dose homogeneity, and normal tissue sparing. Hypofractionated proton radiotherapy in this setting merits Phase I clinical trial investigation

  11. Contribution of radiotherapy to the treatment of malignant tumors, 3. Combined drugs and radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Niibe, Hideo; Takahashi, Iku; Tamaki, Yoshio (Gunma Univ., Maebashi (Japan). School of Medicine)

    1984-09-01

    Effects of cytotoxic agent, hormone, hypoxic cell sensitizer, and radiation protector combined with radiation therapy in cancer management were analysed. The results were as follows: 1) An increase in response was seen in 25% or more of tumor nodules given radiotherapy combined with misonidazole, anoxic cell sensitizer, compared with radiotherpy alone. But the drug was also found to be neurotoxic and peripheral neuropathy. 2) Evidence has been given that Amifostine may protect the mucosal damage from radiation when Amifostine prior to irradiation was administrated to patients with tumor in the head and neck or in the pelvis. 3) There were no difference between five year survival of radiotherapy alone and with chemotherapy for patients with stage I Non-Hodgkin lymphoma. Chemotherapy following radiotherapy for patients with stage II was more effective treatment method than radiotherapy alone. 4) Radiotherapy for patients with prostate cancer was performed to control only primary site. The success rates of local control were over 80%. The near future holds extensive promise for a combination of radiation therapy, cytotoxic chemotherapy, hormone therapy, hypoxic cell sensitizer, and radiation protectors. All of these when used in the appropriate circumstances may yield significant improvements in the therapeutic ratio and in the long-tern control of tumors.

  12. Sonographic Assessment of Parotid and Submandibular Glands in Patients Undergoing 3D Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Johari M

    2016-06-01

    Full Text Available The aim of this study was to evaluate sonographic changes in parotid and submandibular salivary glands in patients undergoing radiotherapy for head and neck malignancies. In addition, salivary changes subsequent to radiotherapy were evaluated objectively and subjectively. Twenty patients(13males and 7females with head and neck malignancies, who had been referred to the Radiotherapy/Oncology Department of the Shahid Madani Hospital in Tabriz, Iran, were included in the study. Length, width, echotexture, echogenicity and margins of parotid and submandibular glands were evaluated before and after radiotherapy using sonography. Peak-systolic velocity(PSV,end-diastolic velocity(EDV and resistive index(RI were also assessed by Doppler sonography. Xerostomia subsequent to radiotherapy was evaluated with the use of two techniques: patients’ self-reported scoring and objective measurement of resting saliva. There was a significant decrease in the width of the parotid gland after radiotherapy compared to baseline(P=0.005.Although the length of the parotid gland and the dimensions of submandibular gland decrease, the differences were not significant. In addition, the echogenicity, echotexture and the margin of the glands change to hypoechoic, heterogenic and irregular, respectively, subsequent to radiotherapy. The Doppler technique showed decrease in PSV and RI and an increase in EDV; however, only the decrease in RI in the submandibular gland was statistically significant(P=0.002.The results showed a significant decrease in salivary flow after radiotherapy(P<0.001.In addition, based on the patients reports, the severity of xerostomia increased significantly after radiotherapy(P<0.001. Songraphic changes of parotid and submandibular glands after radiotherapy should be considered in ultrasound examinations. The damages to the parotid and submandibular glands had significant influence in patient post 3D-CRT.

  13. Adjuvant Chemoradiation for Gastric Cancer Using Epirubicin, Cisplatin, and 5-Fluorouracil Before and After Three-Dimensional Conformal Radiotherapy With Concurrent Infusional 5-Fluorouracil: A Multicenter Study of the Trans-Tasman Radiation Oncology Group

    International Nuclear Information System (INIS)

    Leong, Trevor; Joon, Daryl Lim; Willis, David; Jayamoham, Jayasingham; Spry, Nigel; Harvey, Jennifer; Di Iulio, Juliana; Milner, Alvin; Mann, G. Bruce; Michael, Michael

    2011-01-01

    Purpose: The INT0116 study has established postoperative chemoradiotherapy as the standard of care for completely resected gastric adenocarcinoma. However, the optimal chemoradiation regimen remains to be defined. We conducted a prospective, multicenter study to evaluate an alternative chemoradiation regimen that combines more current systemic treatment with modern techniques of radiotherapy delivery. Methods and Materials: Patients with adenocarcinoma of the stomach who had undergone an R0 resection were eligible. Adjuvant therapy consisted of one cycle of epirubicin, cisplatin, and 5-FU (ECF), followed by radiotherapy with concurrent infusional 5-FU, and then two additional cycles of ECF. Radiotherapy was delivered using precisely defined, multiple-field, three-dimensional conformal techniques. Results: A total of 54 assessable patients were enrolled from 19 institutions. The proportion of patients commencing Cycles 1, 2, and 3 of ECF chemotherapy were 100%, 81%, and 67% respectively. In all, 94% of patients who received radiotherapy completed treatment as planned. Grade 3/4 neutropenia occurred in 66% of patients with 7.4% developing febrile neutropenia. Most neutropenic episodes (83%) occurred in the post-radiotherapy period during cycles 2 and 3 of ECF. Grade 3/4 gastrointestinal toxicity occurred in 28% of patients. In all, 35% of radiotherapy treatment plans contained protocol deviations that were satisfactorily amended before commencement of treatment. At median follow-up of 36 months, the 3-year overall survival rate was estimated at 61.6%. Conclusions: This adjuvant regimen using ECF before and after three-dimensional conformal chemoradiation is feasible and can be safely delivered in a cooperative group setting. A regimen similar to this is currently being compared with the INT0116 regimen in a National Cancer Institute-sponsored, randomized Phase III trial.

  14. Dosimetric comparison between intensity-modulated with coplanar field and 3D conformal radiotherapy with noncoplanar field for postocular invasion tumor.

    Science.gov (United States)

    Wenyong, Tu; Lu, Liu; Jun, Zeng; Weidong, Yin; Yun, Li

    2010-01-01

    This study presents a dosimetric optimization effort aiming to compare noncoplanar field (NCF) on 3 dimensions conformal radiotherapy (3D-CRT) and coplanar field (CF) on intensity-modulated radiotherapy (IMRT) planning for postocular invasion tumor. We performed a planning study on the computed tomography data of 8 consecutive patients with localized postocular invasion tumor. Four fields NCF 3D-CRT in the transverse plane with gantry angles of 0-10 degrees , 30-45 degrees , 240-270 degrees , and 310-335 degrees degrees were isocentered at the center of gravity of the target volume. The geometry of the beams was determined by beam's eye view. The same constraints were prepared with between CF IMRT optimization and NCF 3D-CRT treatment. The maximum point doses (D max) for the different optic pathway structures (OPS) with NCF 3D-CRT treatment should differ in no more than 3% from those with the NCF IMRT plan. Dose-volume histograms (DVHs) were obtained for all targets and organ at risk (OAR) with both treatment techniques. Plans with NCF 3D-CRT and CF IMRT constraints on target dose in homogeneity were computed, as well as the conformity index (CI) and homogeneity index (HI) in the target volume. The PTV coverage was optimal with both NCF 3D-CRT and CF IMRT plans in the 8 tumor sites. No difference was noted between the two techniques for the average D(max) and D(min) dose. NCF 3D-CRT and CF IMRT will yield similar results on CI. However, HI was a significant difference between NCF 3D-CRT and CF IMRT plan (p 3D-CRT versus CF IMRT set-up is very slight. NCF3D-CRT is one of the treatment options for postocular invasion tumor. However, constraints for OARs are needed. 2010 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  15. Configuration control based on risk matrix for radiotherapy treatment

    International Nuclear Information System (INIS)

    Montes de Oca Quinnones, Joe; Torres Valle, Antonio

    2015-01-01

    The incorporation of the science and technique breakthroughs in the application of the radiotherapy represents a challenge so that, the appearance of equipment failure or human mistakes that triggers unfavorable consequences for patients, public, or the occupationally exposed workers; it is also diversified forcing to incorporate besides, as part of the efforts, new techniques for the evaluation of risk and the detection of the weak points that can lead to these consequences. In order to evaluate the risks of the radiotherapy practices there is the SEVRRA code, based on the method of Risk Matrix. The system SEVRRA is the most frequently used code in the applications of risk studies in radiotherapy treatment. On the other hand, starting from the development of tools to control the dangerous configurations in nuclear power plants, it has been developed the SECURE code, which in its application variant of Risk Matrix, has gain a comfortable interface man-machine to make risk analyses to the radiotherapy treatment, molding in this way a lot of combinations of scenarios. These capacities outstandingly facilitate the studies and risk optimization applications in these practices. In the system SECURE-Risk Matrix are incorporated graphic and analytical capacities, which make more flexible the analyses and the subsequent documentation of all the results. The paper shows the the application of the proposed system to an integral risk study for the process of radiotherapy treatment with linear accelerator. (Author)

  16. The impact of computed tomography slice thickness on the assessment of stereotactic, 3D conformal and intensity-modulated radiotherapy of brain tumors.

    Science.gov (United States)

    Caivano, R; Fiorentino, A; Pedicini, P; Califano, G; Fusco, V

    2014-05-01

    To evaluate radiotherapy treatment planning accuracy by varying computed tomography (CT) slice thickness and tumor size. CT datasets from patients with primary brain disease and metastatic brain disease were selected. Tumor volumes ranging from about 2.5 to 100 cc and CT scan at different slice thicknesses (1, 2, 4, 6 and 10 mm) were used to perform treatment planning (1-, 2-, 4-, 6- and 10-CT, respectively). For any slice thickness, a conformity index (CI) referring to 100, 98, 95 and 90 % isodoses and tumor size was computed. All the CI and volumes obtained were compared to evaluate the impact of CT slice thickness on treatment plans. The smallest volumes reduce significantly if defined on 1-CT with respect to 4- and 6-CT, while the CT slice thickness does not affect target definition for the largest volumes. The mean CI for all the considered isodoses and CT slice thickness shows no statistical differences when 1-CT is compared to 2-CT. Comparing the mean CI of 1- with 4-CT and 1- with 6-CT, statistical differences appear only for the smallest volumes with respect to 100, 98 and 95 % isodoses-the CI for 90 % isodose being not statistically significant for all the considered PTVs. The accuracy of radiotherapy tumor volume definition depends on CT slice thickness. To achieve a better tumor definition and dose coverage, 1- and 2-CT would be suitable for small targets, while 4- and 6-CT are suitable for the other volumes.

  17. Early versus delayed postoperative radiotherapy for treatment of low-grade gliomas

    Science.gov (United States)

    Sarmiento, J Manuel; Venteicher, Andrew S; Patil, Chirag G

    2015-01-01

    Background In most people with low-grade gliomas (LGG), the primary treatment regimen remains a combination of surgery followed by postoperative radiotherapy. However, the optimal timing of radiotherapy is controversial. It is unclear whether to use radiotherapy in the early postoperative period, or whether radiotherapy should be delayed until tumour progression occurs. Objectives To assess the effects of early postoperative radiotherapy versus radiotherapy delayed until tumour progression for low-grade intracranial gliomas in people who had initial biopsy or surgical resection. Search methods We searched up to September 2014 the following electronic databases: the Cochrane Register of Controlled Trials (CENTRAL, Issue 8, 2014), MEDLINE (1948 to Aug week 3, 2014), and EMBASE (1980 to Aug week 3, 2014) to identify trials for inclusion in this Cochrane review. Selection criteria We included randomised controlled trials (RCTs) that compared early versus delayed radiotherapy following biopsy or surgical resection for the treatment of people with newly diagnosed intracranial LGG (astrocytoma, oligodendroglioma, mixed oligoastrocytoma, astroblastoma, xanthoastrocytoma, or ganglioglioma). Radiotherapy may include conformal external beam radiotherapy (EBRT) with linear accelerator or cobalt-60 sources, intensity-modulated radiotherapy (IMRT), or stereotactic radiosurgery (SRS). Data collection and analysis Three review authors independently assessed the trials for inclusion and risk of bias, and extracted study data. We resolved any differences between review authors by discussion. Adverse effects were also extracted from the study report. We performed meta-analyses using a random-effects model with inverse variance weighting. Main results We included one large, multi-institutional, prospective RCT, involving 311 participants; the risk of bias in this study was unclear. This study found that early postoperative radiotherapy is associated with an increase in time to

  18. Factors Influencing Neurocognitive Outcomes in Young Patients With Benign and Low-Grade Brain Tumors Treated With Stereotactic Conformal Radiotherapy

    International Nuclear Information System (INIS)

    Jalali, Rakesh; Mallick, Indranil; Dutta, Debnarayan

    2010-01-01

    Purpose: To present the effect of radiotherapy doses to different volumes of normal structures on neurocognitive outcomes in young patients with benign and low-grade brain tumors treated prospectively with stereotactic conformal radiotherapy (SCRT). Methods and Materials: Twenty-eight patients (median age, 13 years) with residual/progressive brain tumors (10 craniopharyngioma, 8 cerebellar astrocytoma, 6 optic pathway glioma and 4 cerebral low-grade glioma) were treated with SCRT to a dose of 54 Gy in 30 fractions over 6 weeks. Prospective neuropsychological assessments were done at baseline before RT and at subsequent follow-up examinations. The change in intelligence quotient (IQ) scores was correlated with various factors, including dose-volume to normal structures. Results: Although the overall mean full-scale IQ (FSIQ) at baseline before RT remained unchanged at 2-year follow-up after SCRT, one third of patients did show a >10% decline in FSIQ as compared with baseline. Logistic regression analysis demonstrated that patients aged 10% drop in FSIQ than older patients (53% vs. 10%, p = 0.03). Dosimetric comparison in patients showing a >10% decline vs. patients showing a 43.2 Gy to >13% of volume of the left temporal lobe were the ones to show a significant drop in FSIQ (p = 0.048). Radiotherapy doses to other normal structures, including supratentorial brain, right temporal lobe, and frontal lobes, did not reveal any significant correlation. Conclusion: Our prospectively collected dosimetric data show younger age and radiotherapy doses to left temporal lobe to be predictors of neurocognitive decline, and may well be used as possible dose constraints for high-precision radiotherapy planning.

  19. Impact of radiation dose on achieving nadir PSA levels after 3-dimensional conformal radiotherapy for patients with localized prostate cancer

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Leibel, Steven A.; Kelson, Suzanne; Fuks, Zvi

    1996-01-01

    Purpose: Several reports have documented the prognostic value of a post-irradiation nadir PSA of ≤1 ng/ml in prostatic cancer patients. The purpose of this study was to determine which pre-treatment and treatment-related variables impact upon achieving such nadir levels. Materials and Methods: Between January 1987 and June 1995, 740 patients with clinically localized prostate cancer were treated with 3-dimensional conformal radiotherapy (3D-CRT). 214 (29%) patients were treated with neo-adjuvant androgen ablation prior to therapy and were excluded from this analysis. Among the 526 evaluable patients, the clinical stage were as follows: T 1 C=128 (24%); T 2 A=76 (14%); T 2 B=116 (22%); T 2 C=99 (19%) and T 3 =107 (21%). The prescription dose to the planning target volume (PTV) was 64.8-68.4 Gy in 87 patients (17%); 70.2 Gy in 191 (36%); 75.6 Gy in 209 (40%) and 81 Gy in 39 (7%). The median pre-treatment PSA value was 11.2 ng/ml (range 0.3-114). The median follow-up was 20 months (range: 6-76 months). Results: 242 patients (46%) had PSA levels which declined to ≤1.0 ng/ml. The median time to a nadir level of ≤1.0 was 15.6 months (range: 1-43 months) from completion of 3D-CRT. 154 (29%) patients continued to show declining PSA levels within the first 2 years after therapy, and 130 patients (25%) failed to nadir at PSA levels of ≤1.0 ng/ml. Among patients with nadir PSA levels ≤1, the 3 year PSA relapse-free survival was 91% compared to 29% for patients with nadir PSA levels >1 ng/ml (p<0.0001). A Cox-regression analysis demonstrated that nadir PSA ≤1 was the strongest predictor of PSA relapse-free survival (p<0.001) followed by Gleason score ≤ 6 (p<0.001) and stage< T3 (p=0.004). Among patients who received doses of ≥75.6 Gy, the likelihood of achieving PSA nadir levels ≤1.0 at 24 and 36 months was 86% and 93%, respectively, compared to 74 and 80%, respectively, among those who received lower doses (p<0.001). Doses of ≥75.6 Gy was the strongest

  20. SU-E-T-63: Carotid Sparing Tomohelical Three Dimensional Conformal Radiotherapy for T1N0 Glottic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hong, C; Ju, S; Ahn, Y; Oh, D; Noh, J; Chung, K; Kim, J; Han, Y; Choi, D [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: We investigated the dosimetric benefit and treatment efficiency of carotid-sparing TomoHelical (TH) three-dimensional conformal radiotherapy (3DCRT) for early glottic cancer. Methods: Computed tomography (CT) simulation was performed for 10 patients with early-stage (T1N0M0) glottic squamous cell carcinoma. The clinical target volume, planning target volume (PTV), carotid artery (CA), and spinal cord (SP) were delineated for each CT data set. Two-field 3DCRT (2F-3DCRT), three-field intensity-modulated radiation therapy (IMRT) (3F-IMRT), TomoHelical-IMRT (TH-IMRT), and TH-3DCRT plans were generated, with a total prescribed dose of 67.5 Gy in 30 fractions to the PTV for each patient. In order to evaluate plan quality, dosimetric characteristics were compared in terms of the conformity index (CI) and homogeneity index (HI) for the PTV, V35, V50, and V63 for the CAs and in terms of the maximum dose for the SP. Additionally, treatment planning and delivery times were compared to evaluate treatment efficiency. Results: The CIs for 3F-IMRT (0.650±0.05), TH-IMRT (0.643±0.03), and TH-3DCRT (0.631±0.03) were much better than that for 2F-3DCRT (0.318±0.03). The HIs for TH-IMRT (1.053±0.01) and TH-3DCRT (1.055±0.01) were slightly better than those for 2F-3DCRT (1.062±0.01) and 3F-IMRT (1.091±0.007). 2F-3DCRT showed poor CA sparing in terms of the V35, V50, and V63 compared to 3F-IMRT, TH-IMRT, and TH-3DCRT (p<0.05), whereas there was no significant dose difference between 3F-IMRT, TH-IMRT, and TH-3DCRT (p>0.05). The maximum dose to the SP with all plans was below 45 Gy. The treatment planning times for 2F-3DCRT (5.9±0.66 min) and TH-3DCRT (7.32±0.94 min) were much lower than those for 3F-IMRT (45.51±2.76 min) and TH-IMRT (35.58±4.41 min), whereas the delivery times with all plans was below 3 minutes. Conclusion: TH-3DCRT showed excellent carotid sparing capability, comparable to that with TH-IMRT, with high treatment efficiency and short planning and

  1. Clinical research on cancer treatment with combined radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Fuwa, Nobukazu; Ito, Yoshiyuki; Kato, Eriko; Koyama, Kazuyuki; Morita, Kozo

    1993-01-01

    There are two purposes of using combined chemotherapy and radiotherapy in the treatment of cancers. One is to suppress distant metastasis, especially micrometastasis; the other is to improve localized control. As a trial of the utility of the former, systemic chemotherapy with CDDP and 5 FU was given successively with radiotherapy to treat nasopharyngeal cancer. The survival rate was significantly improved compared with historical control cases. The main reason for this effectiveness was the improvement of localized control. The suppression of distant metastasis is the subject of future research. As a trial of the utility of the latter, a super-selective intraarterial chemotherapy with CBDCA combined with radiotherapy was used to head and neck localized progressive cancers. The control of localized cancer was remarkably effective. This treatment is considered to be especially suitable for locally advanced tongue cancer and cancer of the root of the tongue. (author)

  2. Dosimetric comparison of the related parameters between simultaneous integrated boost intensity-modulated radiotherapy and sequential boost conformal radiotherapy for postoperative malignant glioma of the brain

    International Nuclear Information System (INIS)

    Shao Qian; Lu Jie; Li Jianbin; Sun Tao; Bai Tong; Liu Tonghai; Yin Yong

    2011-01-01

    Objective: To compare the dosimetric of different parameter of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) with sequential boost conformal radiotherapy (SB-CRT) for postoperative malignant glioma of the brain. Methods: Ten patients with malignant glioma of brain were selected to study. Each patient was simulated all by CT and MRI, and the imagings of CT and MRI were all sent to Pinnacle 3 planning system. The fusion technology with MR-CT imaging was used on Pinnacle 3 planning system. The target volume was delineated and defined based on MRI. The postoperative residual lesion and resection cavity were defined as gross tumor volume (GTV) and expanded GTV some scope was defined as clinical target volume (CTV). The margins of GTV expanded 10 mm and 25 mm were defined as CTV1 and CTV2 respectively. CTV1 and CTV2 all enlarged 5 mm were defined as PTV1 and PTV2 respectively. The plans of simultaneous integrated boost intensity-modulated radiotherapy and sequential boost conformal radiotherapy were respectively designed for each patient using Pinnacle 3 planning system and the dosimetric of different parameter was compared. The prescribe dose of SIB-IMRT was PTV1: 62.5 Gy/25 f, PTV2: 50.0 Gy/25 f; and SB-CRT was PTV1: 66.0 Gy/33 f, PTV2: 50.0 Gy/25 f. The dosimetries of different parameters of SIB-IMRT and SB-CRT were compared by using Paired-Samples T Test. Results: The maximum and mean dose of PTV1, PTV2, and brainstem were of significant difference (P 0.05). Conclusion: The SIB-IMRT plan is better than the SB-CRT plan. The CI and HI of SIB-IMRT are superior to SB-CRT. At the same time, it can preserve the important organs such as brainstem and reduce the mean dose of whole brain. On the other hand it can shorten the total period of therapy time. (authors)

  3. Improving bladder cancer treatment with radiotherapy using separate intensity modulated radiotherapy plans for boost and elective fields

    Energy Technology Data Exchange (ETDEWEB)

    Van Rooijen, D.; Van de Kamer, J.; Hulshof, M.; Koning, C.; Bel, A. [Department of Radiation Oncology, Academic Medical Center, Amsterdam (Netherlands)

    2010-06-01

    The aim of this study is to investigate to what extent IMRT can decrease the dose to the organs at risk in bladder cancer treatment compared with conformal treatment while making separate treatment plans for the elective field and the boost. Special attention is paid to sparing small intestines. Twenty patients who were treated with the field-in-field technique (FiF) were re-planned with intensity modulated radiotherapy (IMRT) using five and seven beams, respectively. Separate treatment plans were made for the elective field (including the pelvic lymph nodes) and the boost, which enables position correction for bone and tumour separately. The prescribed dose was 40 Gy to the elective field and 55 or 60 Gy to the planning target volume (PTV). For bladder and rectum, V{sub 45}Gy and V{sub 55}Gy were compared, and for small intestines, V{sub 25}Gy and V{sub 40}Gy. The dose distribution with IMRT conformed better to the shape of the target. There was no significant difference between the techniques in dose to the healthy bladder. The median V{sub 40}Gy of the small intestines decreased from 114 to 66 cc (P = 0.001) with five beam IMRT, and to 55 cc (P = 0.001) with seven beam IMRT compared with FiF. V{sub 45}Gy for rectum decreased from 34.2% to 17.5% (P = 0.004) for both five and seven beam plans, while V{sub 55}Gy for rectum remained the same. With IMRT, a statistically significant dose decrease to the small intestines can be achieved while covering both tumour and elective PTV adequately.

  4. Improving bladder cancer treatment with radiotherapy using separate intensity modulated radiotherapy plans for boost and elective fields

    International Nuclear Information System (INIS)

    Van Rooijen, D.; Van de Kamer, J.; Hulshof, M.; Koning, C.; Bel, A.

    2010-01-01

    The aim of this study is to investigate to what extent IMRT can decrease the dose to the organs at risk in bladder cancer treatment compared with conformal treatment while making separate treatment plans for the elective field and the boost. Special attention is paid to sparing small intestines. Twenty patients who were treated with the field-in-field technique (FiF) were re-planned with intensity modulated radiotherapy (IMRT) using five and seven beams, respectively. Separate treatment plans were made for the elective field (including the pelvic lymph nodes) and the boost, which enables position correction for bone and tumour separately. The prescribed dose was 40 Gy to the elective field and 55 or 60 Gy to the planning target volume (PTV). For bladder and rectum, V 45 Gy and V 55 Gy were compared, and for small intestines, V 25 Gy and V 40 Gy. The dose distribution with IMRT conformed better to the shape of the target. There was no significant difference between the techniques in dose to the healthy bladder. The median V 40 Gy of the small intestines decreased from 114 to 66 cc (P = 0.001) with five beam IMRT, and to 55 cc (P = 0.001) with seven beam IMRT compared with FiF. V 45 Gy for rectum decreased from 34.2% to 17.5% (P = 0.004) for both five and seven beam plans, while V 55 Gy for rectum remained the same. With IMRT, a statistically significant dose decrease to the small intestines can be achieved while covering both tumour and elective PTV adequately.

  5. Evaluation of Sentinel Lymph Node Dose Distribution in 3D Conformal Radiotherapy Techniques in 67 pN0 Breast Cancer Patients.

    Science.gov (United States)

    Witucki, Gerlo; Degregorio, Nikolaus; Rempen, Andreas; Schwentner, Lukas; Bottke, Dirk; Janni, Wolfgang; Ebner, Florian

    2015-01-01

    Introduction. The anatomic position of the sentinel lymph node is variable. The purpose of the following study was to assess the dose distribution delivered to the surgically marked sentinel lymph node site by 3D conformal radio therapy technique. Material and Method. We retrospectively analysed 70 radiotherapy (RT) treatment plans of consecutive primary breast cancer patients with a successful, disease-free, sentinel lymph node resection. Results. In our case series the SN clip volume received a mean dose of 40.7 Gy (min 28.8 Gy/max 47.6 Gy). Conclusion. By using surgical clip markers in combination with 3D CT images our data supports the pathway of tumouricidal doses in the SN bed. The target volume should be defined by surgical clip markers and 3D CT images to give accurate dose estimations.

  6. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    International Nuclear Information System (INIS)

    Saenz, Daniel L.; Paliwal, Bhudatt R.; Bayouth, John E.

    2014-01-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 ( 60 Co) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI), conformity index (CI), and volume receiving 60 Co ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system. (author)

  7. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans.

    Science.gov (United States)

    Saenz, Daniel L; Paliwal, Bhudatt R; Bayouth, John E

    2014-04-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI), conformity index (CI), and volume receiving ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system.

  8. Treatment of bone metastases with palliative radiotherapy: Patients' treatment preferences

    International Nuclear Information System (INIS)

    Szumacher, Ewa; Llewellyn-Thomas, Hillary; Franssen, Edmee; Chow, Edward; Boer, Gerrit de; Danjoux, Cyril; Hayter, Charles; Barnes, Elizabeth; Andersson, Lourdes

    2005-01-01

    Purpose: To determine the proportion of patients undergoing palliative radiotherapy (RT) for bone pain who would like to participate in the decision-making process, and to determine their choice of palliative RT regimen (2000 cGy in five fractions vs. 800 cGy in one fraction) for painful bone metastases. Methods and Materials: Eligible patients were approached and all patients agreeing to participate provided written informed consent. Patients' decisional preferences were studied using a five-statement preference instrument. A decision board was used to help patients decide their preferred palliative RT regimen. Factors influencing patients' choices were studied using a visual analog scale. Results: A total of 101 patients were enrolled in the study (55 women and 46 men). The preferences for decision-making were as follows: 30 active, 47 collaborative, and 24 passive. Most (55 [76%] of 72) patients favored one fraction of palliative RT (95% confidence interval, 65-86%). Patients were more likely to select the 800 cGy in one fraction because of the convenience of the treatment plan (odds ratio, 1.024; 95% confidence interval, 1.004-1044) but were less likely to choose it because of the chance of bone fracture (odds ratio, 0.973; 95% confidence interval, 0.947-1.000) compared with 2000 cGy in five fractions. Conclusion: Most participating patients preferred to decide either by themselves or with the radiation oncologists which treatment option they preferred. An 800-cGy-in-one-fraction regimen was favored, independent of the treated site. The convenience of the treatment plan and the likelihood of bone fracture were the most important factors influencing patients' choice

  9. Radiotherapy

    International Nuclear Information System (INIS)

    Prosnitz, L.R.; Kapp, D.S.; Weissberg, J.B.

    1983-01-01

    This review highlights developments over the past decade in radiotherapy and attempts to summarize the state of the art in the management of the major diseases in which radiotherapy has a meaningful role. The equipment, radiobiology of radiotherapy and carcinoma of the lung, breast and intestines are highlighted

  10. Detention and positioning system for patient Treatment with conventional radiotherapy

    International Nuclear Information System (INIS)

    Hueso Bernad, Nuria; Tirado Porcar, Miriam; Del Castillo Arres, M. Jose; Broseta Tormos, M. Mercedes; Franch Martinez, Silvia; Suarez Dieguez, Raquel; Roures Ramos, M.Teresa

    2009-01-01

    The first step in what we call in radiotherapy S imulation and Planning o f radiation, is the correct choice of patient position and methods to use for this position is maintained along both the simulation and planning as the radiation treatment. The choice of position is directly linked to the choice of immobilizer to be used. (Author)

  11. Markov chain Monte Carlo methods in radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Hugtenburg, R.P.

    2001-01-01

    The Markov chain method can be used to incorporate measured data in Monte Carlo based radiotherapy treatment planning. This paper shows that convergence to the measured data, within the target precision, is achievable. Relative output factors for blocked fields and oblique beams are shown to compare well with independent measurements according to the same criterion. (orig.)

  12. Progress of radiotherapy by three-dimensional treatment planning

    International Nuclear Information System (INIS)

    Imada, Hajime; Nomoto, Satoshi; Takahashi, Hiroyuki; Nakata, Hajime

    1998-01-01

    The recent progress of three-dimensional radiation treatment planning was reviewed. And clinical cases such as lung cancer and breast cancer are introduced. In the University of Occupational and Development Health, the treatment system FOCUS which is made up of CT simulator and linac was used mainly. Three-dimensional treatment planning was carried for about 90% of 330 patients who underwent radiotherapy for one year. The target becomes to be accurate and dose distribution with all CT slices in radiation field can be confirmed by using three-dimensional radiation treatment planning apparatus. High dose irradiation localized to tumor part is possible. Relations between total dose and volume of normal tissue and/or tumor can be estimated numerically and easily by DVH. A prediction of indication and affection became possible by this procedure. In conclusion, generalization of three-dimensional radiation treatment planning will bring progress of more effective radiotherapy with less adverse reaction. (K.H.). 21 refs

  13. Impact of inter- and intrafraction deviations and residual set-up errors on PTV margins. Different alignment techniques in 3D conformal prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Langsenlehner, T.; Doeller, C.; Winkler, P.; Kapp, K.S.; Galle, G.

    2013-01-01

    The aim of this work was to analyze interfraction and intrafraction deviations and residual set-up errors (RSE) after online repositioning to determine PTV margins for 3 different alignment techniques in prostate cancer radiotherapy. The present prospective study included 44 prostate cancer patients with implanted fiducials treated with three-dimensional (3D) conformal radiotherapy. Daily localization was based on skin marks followed by marker detection using kilovoltage (kV) imaging and subsequent patient repositioning. Additionally, in-treatment megavoltage (MV) images were obtained for each treatment field. In an off-line analysis of 7,273 images, interfraction prostate motion, RSE after marker-based prostate localization, prostate position during each treatment session, and the effect of treatment time on intrafraction deviations were analyzed to evaluate PTV margins. Margins accounting for interfraction deviation, RSE and intrafraction motion were 14.1, 12.9, and 15.1 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction for skin mark alignment and 9.6, 8.7, and 2.6 mm for bony structure alignment, respectively. Alignment to implanted markers required margins of 4.6, 2.8, and 2.5 mm. As margins to account for intrafraction motion increased with treatment prolongation PTV margins could be reduced to 3.9, 2.6, and 2.4 mm if treatment time was ≤ 4 min. With daily online correction and repositioning based on implanted fiducials, a significant reduction of PTV margins can be achieved. The use of an optimized workflow with faster treatment techniques such as volumetric modulated arc techniques (VMAT) could allow for a further decrease. (orig.)

  14. Advances in conformal radiotherapy using Monte Carlo Code to design new IMRT and IORT accelerators and interpret CT numbers

    CERN Document Server

    Wysocka-Rabin, A

    2013-01-01

    The introductory chapter of this monograph, which follows this Preface, provides an overview of radiotherapy and treatment planning. The main chapters that follow describe in detail three significant aspects of radiotherapy on which the author has focused her research efforts. Chapter 2 presents studies the author worked on at the German National Cancer Institute (DKFZ) in Heidelberg. These studies applied the Monte Carlo technique to investigate the feasibility of performing Intensity Modulated Radiotherapy (IMRT) by scanning with a narrow photon beam. This approach represents an alternative to techniques that generate beam modulation by absorption, such as MLC, individually-manufactured compensators, and special tomotherapy modulators. The technical realization of this concept required investigation of the influence of various design parameters on the final small photon beam. The photon beam to be scanned should have a diameter of approximately 5 mm at Source Surface Distance (SSD) distance, and the penumbr...

  15. Intraoperative radiotherapy for the treatment of gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Satomura, Kisaku; Inamoto, Shun; Honda, Kazuo; Takahashi, Masaji [Kyoto Univ. (Japan). Faculty of Medicine

    1982-12-01

    Clinical results of intraoperative radiotherapy for gastric cancer were reported. One hundred and five cases of gastric cancer were treated by intraoperative radiotherapy. Whatever the stage of the patient was, 3-year survival rate was found to be better in the radiotherapy group than that of the control group (treated surgical resection only). Five year survival rate of the stages III and IV in the radiotherapy group was better than the control group. Unfavorable side effects were observed in 4 cases out of 105 cases. In one case, penetration of postoperative peptic ulcer into the irradiated aortic wall was found by autopsy. Two cases of bile duct stenosis and one case of ileus due to acutely developed peritonitis carcinomatosa were experienced. In conclusion, intraoperative radiotherapy immediately after surgical resection for the treatment of gastric cancer was found to be an effective method. The most effective application of the method appears to be to cases of stage II and III without liver metastasis and peritoneal disseminations (H/sub 0/P/sub 0/, M, A).

  16. Simultaneous integrated boost intensity-modulated radiotherapy versus 3-dimensional conformal radiotherapy in preoperative concurrent chemoradiotherapy for locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Bong Kyung; Kang, Min Kyul; Kim, Jae Chul [Dept. of Radiation Oncology, Kyungpook National University School of Medicine, Daegu (Korea, Republic of); Kim, Min Young; Choi, Gyu Seog; Kim, Jong Gwang; Kang, Byung Woog; Kim, Hye Jin; Park, Soo Yeun [Kyungpook National University Chilgok Hospital, Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2017-09-15

    To evaluate the feasibility of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for preoperative concurrent chemoradiotherapy (PCRT) in locally advanced rectal cancer (LARC), by comparing with 3-dimensional conformal radiotherapy (3D-CRT). Patients who were treated with PCRT for LARC from 2015 January to 2016 December were retrospectively enrolled. Total doses of 45 Gy to 50.4 Gy with 3D-CRT or SIB-IMRT were administered concomitantly with 5-fluorouracil plus leucovorin or capecitabine. Surgery was performed 8 weeks after PCRT. Between PCRT and surgery, one cycle of additional chemotherapy was administered. Pathologic tumor responses were compared between SIB-IMRT and 3D-CRT groups. Acute gastrointestinal, genitourinary, hematologic, and skin toxicities were compared between the two groups based on the RTOG toxicity criteria. SIB-IMRT was used in 53 patients, and 3D-CRT in 41 patients. After PCRT, no significant differences were noted in tumor responses, pathologic complete response (9% vs. 7%; p = 1.000), pathologic tumor regression Grade 3 or higher (85% vs. 71%; p = 0.096), and R0 resection (87% vs. 85%; p = 0.843). Grade 2 genitourinary toxicities were significantly lesser in the SIB-IMRT group (8% vs. 24%; p = 0.023), but gastrointestinal toxicities were not different across the two groups. SIB-IMRT showed lower GU toxicity and similar tumor responses when compared with 3D-CRT in PCRT for LARC.

  17. A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

    International Nuclear Information System (INIS)

    Poppe, Matthew M.; Narra, Venkat; Yue, Ning J.; Zhou Jinghao; Nelson, Carl; Jabbour, Salma K.

    2011-01-01

    We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

  18. Changes in sexual function after radiotherapy treatment of prostate cancer

    International Nuclear Information System (INIS)

    Beckendorf, V.; Hay, M.; Rozan, R.; Lagrange, J.L.; N'Guyen, T.; Giraud, B.

    1996-01-01

    The objective was to assess sexual function before and after definitive irradiation for the treatment of cancer of the prostate. The study comprised 67 patients (mean age 68 years) treated in five radiotherapy departments and assessed with repeated questionnaires about their libido, arousal, frequency and quality of intercourse, and sexual satisfaction. Interviews were obtained before radiotherapy and at the end of the first year after treatment. Sixty-three patients were married and 50 had a sexually effective partner. Forty-six patients presented with another pathology or medical treatment capable of inducing sexual dysfunction. Before radiotherapy, 40 patients were sexually active, with good to acceptable intercourse. Between 10 and 24 months after the end of radiotherapy, no disease progression was observed and prostate-specific antigen levels remained high in only two patients. Sexual function was preserved in 67% of patients but only 50% observed no change. The functional prognosis seemed to be related to the initial frequency and quality of intercourse; more than three times per month, the prognosis remained good, under three per month, it was poor. The patient's age was a predictive factor for the frequency of intercourse. (author)

  19. Radiotherapy treatment checking procedures throughout Australasia: results of a survey

    International Nuclear Information System (INIS)

    Duggan, L.; Kron, T.; Howlett, S.

    1996-01-01

    In July 1995, a questionnaire was forwarded to thirty two physicists overseeing Radiation Oncology Departments and brachytherapy in hospitals throughout Australia and New Zealand. From the thirty seven hospitals reached by this survey, details were gathered on thirty hospitals, including the Newcastle In most radiotherapy centres where treatment planning is performed by radiation therapists, at least some of the treatment sheets and their calculations are double checked by radiotherapy physicists. While 23% checked the treatment sheets of all patients, in the majority of centres physicists were found to check only a minor selection, that is, less than 20% of all treatment sheets. Only in six centres physicists were not involved. 5 refs., 4 tabs., 5 figs

  20. Present and future of the Image Guided Radiotherapy (I.G.R.T.) and its applications in lung cancer treatment

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Ferreira, I.; Isambert, A.; Le Pechoux, C.; Mornex, F.

    2007-01-01

    These last years, the new irradiation techniques as the conformal 3D radiotherapy and the IMRT are strongly correlated with the technological developments in radiotherapy. The rigorous definition of the target volume and the organs at risk required by these irradiation techniques, imposed the development of various image guided patient positioning and target tracking techniques. The availability of these imaging systems inside the treatment room has lead to the exploration of performing real-time adaptive radiation therapy. In this paper we present the different image guided radiotherapy (IGRT) techniques and the adaptive radiotherapy (ART) approaches. IGRT developments are focused in the following areas: 1) biological imaging for better definition of tumor volume; 2) 4D imaging for modeling the intra-fraction organ motion; 3) on-board imaging system or imaging devices registered to the treatment machines for inter-fraction patient localization; and 4) treatment planning and delivery schemes incorporating the information derived from the new imaging techniques. As this paper is included in the 'Cancer Radiotherapie' special volume dedicated to the lung cancers, in the description of the different IGRT techniques we try to present the lung tumors applications when this is possible. (author)

  1. Pre-Radiotherapy dental evaluation criteria and treatment needs of oral side effects after head and neck radiotherapy

    International Nuclear Information System (INIS)

    Gonzalez-Arriagada, Wilfredo Alejandro; Santos-Silva, Alan Roger; Carvalho de Andrade, Marco Aurelio; De Andrade Elias, Rogerio; Ajudarte Lopes, Marcio

    2010-01-01

    The objective of this review is to present pre-radiotherapy evaluation criteria and the main needs for treatment of these patients after the radiation therapy. Were revised articles in English, Spanish and Portuguese language between 1995 and 2009 indexed in Pubmed and Scielo. The keywords were oral cancer and radiotherapy, complications in head and neck radiotherapy, oral pre-radiotherapy evaluation.The adverse complications of radiotherapy in head and neck area could be temporary or late. The late effects, such as radiation caries and osteorradionecrosis could be directly associated with the fact that previous dental evaluation was not performed and can severely affect the post-operatory quality of life. The participation of the dentist in the multidisciplinary team and dental evaluation of the patients that will receive radiotherapy in the head and neck area are of vital importance to improve the post-operatory quality of life of these patients

  2. Dosimetric implications of changes in patient repositioning and organ motion in conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Miralbell, Raymond; Oezsoy, Orhan; Pugliesi, Angela; Carballo, Natalia; Arnalte, Raquel; Escude, Lluis; Jargy, Clara; Nouet, Philippe; Rouzaud, Michel

    2003-01-01

    Purpose: To assess the influence of patient repositioning and organ motion on dose distribution within the prostate and the seminal vesicles (clinical target volume, (CTV)). Material and methods: Nine patients were simulated and treated in the supine position, with an empty bladder, and without immobilization devices. While on treatment, patients underwent weekly pelvic computed tomography (CT) scans under conditions identical to those at simulation. Patients were aligned using lasers on anterior and lateral skin tattoos, onto which lead markers were placed. After each CT scan (n=53) the CTV was redefined by contouring, and a new isocenter was obtained. A six-field technique was used. The field margins around the CTV were 20 mm in the cranio-caudal axis, and 13 mm in the other axes, except in the lateral fields where a 10 mm posterior margin was used. Dose-volume histograms (DVHs) for each organ were compared with those determined at simulation, using the notion of the proportional change in the area under the CTV-DVH curve resulting from a change in treatment plan (cDVH). Results: The reproducibility of the dose distribution was good for the prostate (%cDVH, mean±SD: -0.97±2.11%) and less than optimal for the seminal vesicles (%cDVH, mean±SD: -4.66±10.45%). When correlating prostate %cDVH variations with displacements of the isocenter in the Y axis (antero-posterior) the %cDVH exceeded (-)5% in only two dosimetries, both with an isocenter shift of >10 mm. For the seminal vesicles, however, ten out of 53 dosimetries showed a %cDVH exceeding (-) 5%. In nine of these ten dose distribution studies the posterior shift of the isocenter exceeded 8 mm. Conclusions: Precise targeting of prostate radiotherapy is primarily dependent on careful daily set-up and on random changes in rectal geometry. Margins no less than 10 mm around the prostate and at least 15 mm around the seminal vesicles are probably necessary to insure adequate target coverage with a six

  3. Conformity index: A review

    International Nuclear Information System (INIS)

    Feuvret, Loic; Noel, Georges; Mazeron, Jean-Jacques; Bey, Pierre

    2006-01-01

    We present a critical analysis of the conformity indices described in the literature and an evaluation of their field of application. Three-dimensional conformal radiotherapy, with or without intensity modulation, is based on medical imaging techniques, three-dimensional dosimetry software, compression accessories, and verification procedures. It consists of delineating target volumes and critical healthy tissues to select the best combination of beams. This approach allows better adaptation of the isodose to the tumor volume, while limiting irradiation of healthy tissues. Tools must be developed to evaluate the quality of proposed treatment plans. Dosimetry software provides the dose distribution in each CT section and dose-volume histograms without really indicating the degree of conformity. The conformity index is a complementary tool that attributes a score to a treatment plan or that can compare several treatment plans for the same patient. The future of conformal index in everyday practice therefore remains unclear

  4. Radiotherapy as a conservative treatment in breast cancer

    International Nuclear Information System (INIS)

    Pfuhl, O.R. von; Miola, U.J.; Campos, J.C.F. de

    1977-01-01

    The review of 545 cases of cancer of the breast, 10% of which were treated by exclusive radiotherapy, emphasized the trend towards conservative treatment, because 29,8% of mastectomized women died within two years from the operation with distant metastases. As it is possible with radiotherapy to cause fibrosis or keep inactive breast tumors up to 5 cm diameter for two years or longer, one must consider irradiation as a good option for young women with small tumors. A combination was used of tangencial radiotherapy up to 5.000 rads to the whole breast with a boost dose two weeks later of 3.000 to 4.000 rads by means of intersticial radiotherapy given only to the palpable tumor. This was fulfilled by the afterloading method according to a system described as geometrization of the breast by parallel plates where holes were drilled for the needles. No recurrence was seen in 4 years in the selected group of 12 patients submitted to the mentioned treatment [pt

  5. Effect of IMRT and three-dimensional conformal radiotherapy on oral Candida colonization: A comparative study

    Directory of Open Access Journals (Sweden)

    Jasmine Shanthi Kamath

    2017-01-01

    Conclusion: Although candidiasis is seen regardless of the type of radiation therapy used, the oral environment is more stable after intensity-modulated radiation therapy as and when compared to 3D CRT. Salivary substitutes and good oral hygiene before, during, and after radiotherapy could be used to increase oral clearance and to decrease the chance of candidiasis.

  6. Radiotherapy in head and neck: a standard treatment?

    International Nuclear Information System (INIS)

    Santini Blasco, A; Torres Lopez, M; Apardian Manougian, R

    1998-01-01

    The present work is an exhaustive revision of the literature regarding the employment of combined treatments of radiochemotherapy in the head and neck neoplasms. The sanitary importance of this group of illnesses starts to become remarkable not only due to their frequency but for the high percentage of patients that present themselves for consultation with an advanced illness where the results of the classic treatments of surgery and radiotherapy are discouraging. These results are poor for the survival as well as in the quality of this. It analyzes the role of the different pharmaceuticals used in patients as well as the fundamentally different associations with radiotherapy: neoadjuvant, adjuvant and concomitant. These results allow to affirm that this treatment form is elected for those patients with advanced tumors of head and neck with a general state that allows to tolerate a bigger toxicity [es

  7. Volume and hormonal effects for acute side effects of rectum and bladder during conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Peeters, Stephanie T.H.; Hoogeman, Mischa S.; Heemsbergen, Wilma D.; Slot, Annerie; Tabak, Hans; Koper, Peter C.M.; Lebesque, Joos V.

    2005-01-01

    Purpose: To identify dosimetric variables predictive of acute gastrointestinal (GI) and genitourinary (GU) toxicity and to determine whether hormonal therapy (HT) is independently associated with acute GI and GU toxicity in prostate cancer patients treated with conformal radiotherapy (RT). Methods and Materials: This analysis was performed on 336 patients participating in a multicenter (four hospitals) randomized trial comparing 68 Gy and 78 Gy. The clinical target volume consisted of the prostate with or without the seminal vesicles, depending on the risk of seminal vesicle involvement. The margin from the clinical target volume to the planning target volume was 1 cm. For these patients, the treatment plan for a total dose of 68 Gy was used, because nearly all toxicity appeared before the onset of the 10-Gy boost. Acute toxicity ( 3 months before RT). Results: Acute GI toxicity Grade 2 or worse was seen in 46% of the patients. Patients with long-term neoadjuvant HT experienced less Grade 2 or worse toxicity (27%) compared with those receiving short-term neoadjuvant HT (50%) and no HT (50%). The volumes of the prostate and seminal vesicles were significantly smaller in both groups receiving neoadjuvant HT compared with those receiving no HT. In multivariate logistic regression analysis, including the two statistically significant clinical variables neoadjuvant HT and hospital, a volume effect was found for the relative, as well as absolute, rectal wall volumes exposed to intermediate and high doses. Of all the length parameters, the relative rectal length irradiated to doses of ≥5 Gy and ≥30 Gy and absolute lengths receiving ≥5-15 and 30 Gy were significant. Acute GU toxicity Grade 2 or worse was reported in 56% of cases. For patients with pretreatment GU symptoms, the rate was 93%. The use of short-term and long-term neoadjuvant HT resulted in more GU toxicity (73% and 71%) compared with no HT (50%). In multivariate analysis, containing the variables

  8. Protocol updated for the treatment of patients in radiotherapy with implanted cardiac devices

    International Nuclear Information System (INIS)

    Martin Martin, G.; Bermudez Luna, R.; Rodriguez Rodriguez, C.; Lopez Fernandez, A.; Rodriguez Perez, A.; Sotoca Ruiz, A.

    2013-01-01

    Radiotherapy treatment can be safely performed in patients with pacemakers or implanted defibrillators, however, it is very important to ensure that the patient receives the minimum dose possible in your heart device. Is considered essential good coordination with the cardiology service before, during and after radiotherapy treatment for the patient safety. Finally we present a protocol updated to treat these patients in radiotherapy. (Author)

  9. Efficacy of post-operative radiotherapy in the treatment of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Api, P; Corcione, S; Magnoni, G

    1985-01-01

    A clinical evaluation regarding the efficacy of post-operative radiotherapy in 294 patients with breast cancer is presented. In the author's opinion post-operative radiotherapy is fundamental in the treatment of this tumor. 21 refs.

  10. Quality control in radiotherapy treatment: Radiation induced myelopathy

    International Nuclear Information System (INIS)

    Fernandez-Vicioso, E.; Ruiz-Cruces, R.

    2001-01-01

    Direct injury of the spinal cord has been reported many times, particularly in cases of overexposures with radiotherapy of neoplasm that occurred outside the Central Nervous System. Permanent damage to the spinal cord is the most feared complication of radiation therapy treatments and one of the relatively common causes of litigation for medical malpractice in the context of cancer treatment. We have learned from clinical experience, data from randomized trials and animal experimentation, the dose tolerance as well as the interfraction interval for hyperfractionation regimes. We are still lacking precious clinical information, in particular the dose tolerance in combined modality treatments that represent the vast majority of modern treatments. (author)

  11. Late rectal toxicity after conformal radiotherapy of prostate cancer (I): multivariate analysis and dose-response

    International Nuclear Information System (INIS)

    Skwarchuk, Mark W.; Jackson, Andrew; Zelefsky, Michael J.; Venkatraman, Ennapadam S.; Cowen, Didier M.; Levegruen, Sabine; Burman, Chandra M.; Fuks, Zvi; Leibel, Steven A.; Ling, C. Clifton

    2000-01-01

    Purpose: The purpose of this paper is to use the outcome of a dose escalation protocol for three-dimensional conformal radiation therapy (3D-CRT) of prostate cancer to study the dose-response for late rectal toxicity and to identify anatomic, dosimetric, and clinical factors that correlate with late rectal bleeding in multivariate analysis. Methods and Materials: Seven hundred forty-three patients with T1c-T3 prostate cancer were treated with 3D-CRT with prescribed doses of 64.8 to 81.0 Gy. The 5-year actuarial rate of late rectal toxicity was assessed using Kaplan-Meier statistics. A retrospective dosimetric analysis was performed for patients treated to 70.2 Gy (52 patients) or 75.6 Gy (119 patients) who either exhibited late rectal bleeding (RTOG Grade 2/3) within 30 months after treatment (i.e., 70.2 Gy--13 patients, 75.6 Gy--36 patients) or were nonbleeding for at least 30 months (i.e., 70.2 Gy--39 patients, 75.6 Gy--83 patients). Univariate and multivariate logistic regression was performed to correlate late rectal bleeding with several anatomic, dosimetric, and clinical variables. Results: A dose response for ≥ Grade 2 late rectal toxicity was observed. By multivariate analysis, the following factors were significantly correlated with ≥ Grade 2 late rectal bleeding for patients prescribed 70.2 Gy: 1) enclosure of the outer rectal contour by the 50% isodose on the isocenter slice (i.e., Iso50) (p max (p max

  12. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    Directory of Open Access Journals (Sweden)

    Daniel L Saenz

    2014-01-01

    Full Text Available ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60 with 0.35 Tesla magnetic resonance imaging (MRI allows for magnetic resonance (MR-guided intensity-modulated radiation therapy (IMRT delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI, conformity index (CI, and volume receiving <20% of prescription dose (DRx were calculated to assess the plans. The 95% confidence intervals were recorded for all measurements and presented with the associated bars in graphs. The homogeneity index (D5/D95 had a 1-5% inhomogeneity increase for head and neck, 3-8% for lung, and 4-16% for prostate. CI revealed a modest conformity increase for lung. The volume receiving 20% of the prescription dose increased 2-8% for head and neck and up to 4% for lung and prostate. Overall, for head and neck Co-60 ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system.

  13. The evolution of rectal and urinary toxicity and immune response in prostate cancer patients treated with two three-dimensional conformal radiotherapy techniques

    Czech Academy of Sciences Publication Activity Database

    Vránová, J.; Vinakurau, S.; Richter, J.; Starec, M.; Fišerová, Anna; Rosina, J.

    2011-01-01

    Roč. 2, č. 6 (2011), s. 1-13 ISSN 1748-717X R&D Projects: GA AV ČR IAA500200620 Institutional research plan: CEZ:AV0Z50200510 Keywords : 3-dimensional conformal radiotherapy (3DCRT) * gastrointestinal and genitourinary toxicity * prostate cancer Subject RIV: EC - Immunology Impact factor: 2.321, year: 2011

  14. Metastatic breast cancer in the eye and orbit, use three-dimensional conformal radiotherapy. Our first experience

    International Nuclear Information System (INIS)

    Correa Pablos, Tamara; Caceres Toledo, Maria

    2009-01-01

    The eye and orbit metastases are a significant clinical problem, both by the inability and the deterioration in the quality of life that occur. The most common malignant tumors in the eye and orbit is metastasis. Cancer breast cancer is the most common tumor metastatic to the eye and orbit in a 40% and 50% of cases according to different series. With the introduction of Three-Dimensional Conformal Radiotherapy (3D-CRT) in our hospital from In 2007 we were able to treat patients with cancer different regions with the technique (2D) was impossible because caused irreparable damage to surrounding healthy tissue in this way thanks to potential of 3D technology to shape the planning volume will ensure greater protection for critical organs. (Author)

  15. Registration and planning of radiotherapy and proton therapy treatment

    International Nuclear Information System (INIS)

    Bausse, Jerome

    2010-01-01

    Within the frame of an update and renewal project, the Orsay Proton Therapy Centre of the Curie Institute (IPCO) renews its software used for the treatment of patients by proton therapy, a radiotherapy technique which uses proton beams. High energies used in these treatments and the precision provided by proton particle characteristics require a more precise patient positioning than conventional radiotherapy: proton therapy requires a precision of about a millimetre. Thus, markers are placed on the skull which are generally well accepted by patients, but are a problem in the case of paediatric treatment, notably for the youngest children whose skull is still growing. The first objective of this research is thus to use only intrinsic information from X-ray images used when positioning the patient. A second objective is to make the new software (TPS Isogray) perfectly compatible with IPCO requirements by maintaining the strengths of the previous TPS (Treatment Planning System) and being prepared to the implementation of a new installation. After a presentation of the context and state of the art in radiotherapy and patient positioning, the author proposes an overview of 2D registration methods, presents a new method for 2x2D registration, and addresses the problem of 3D registration. Then, after a presentation of proton therapy, the author addresses different specific issues and aspects: the compensator (simulation, calculation, and tests), dose calculation, the 'Pencil-Beam' algorithm, tests, and introduced improvements [fr

  16. The value of radiotherapy for the treatment of meningeal melanocytoma

    International Nuclear Information System (INIS)

    Rades, D.; Karstens, J.H.; Tatagiba, M.; Brandis, A.; Dubben, H.H.

    2002-01-01

    Background: Meningeal melanocytoma is described as rare benign lesion with a high risk of recurrence. There are no well-substantiated treatment recommendations in the literature. Only case reports have been published by now. Patients and Methods: In 1997 a patient was irradiated for a recurrent spinal meningeal melanocytoma and 2 years later for brain metastases indicating malignant transformation. This case gave rise to a literature review for therapeutic options. All sufficiently documented cases published since 1972, when the term meningeal melanocytoma was established, were evaluated. Based on published and on original data recurrence and overall survival rates up to 5 years were calculated for three different therapeutic approaches, namely complete tumor resection, incomplete resection with subsequent radiotherapy, and incomplete resection alone. Statistical evaluation was performed using the χ 2 test and Kaplan-Meier-analysis. Results: 53 patients (including our patient) met selection criteria. Complete tumor resection was superior to incomplete resection alone with lower recurrence (4-38% versus 50-92%) and better overall survival rates (86-95% versus 30-58%). After incomplete resection radiotherapy seemed to improve prognosis (recurrence 15-45%; overall survival 91-92%). Between complete resection and incomplete resection plus radiotherapy no significant differences were observed. Conclusions: For meningeal melanocytoma complete resection must be regarded as the best of the modalities compared. After incomplete resection radiotherapy should be considered, although a specific radiotherapeutic regimen cannot be recommended at present. However, for multiple cranial or spinal lesions total cranial irradiation or craniospinal irradiation is indicated. (orig.) [de

  17. Situation of radiotherapy in 2010 - context and methods, data for 2003/2010, synthesis

    International Nuclear Information System (INIS)

    2011-03-01

    Illustrated by data tables and figures, this report first gives an overview of the status and situation of European and French radiotherapy centres, and of care activity authorizations regarding external radiotherapy. It gives an overview of equipment used for treatments and for treatment preparation and delivery, and of the different treatment techniques (three dimensional conformational, intensity-modulated conformational, stereotactic, whole body radiotherapy, proton-therapy). It comments the activity of radiotherapy centres: patients (age, sessions, and treated pathologies), comments data regarding medical and paramedical personnel involved in radiotherapy, and financial data regarding radiotherapy in 2009

  18. Combined modality treatment with radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Tannock, I.F.; Toronto Univ., ON

    1989-01-01

    The present paper discusses some of the methodological issues which can confound the interpretation of clinical trials of combined modality treatment. It reviews some of the larger randomized trials which have evaluated combined modality treatment in cancers of the head and neck, lung, gastrointestinal tract and bladder. It concludes that adequate trials have yet to be performed in many of thses sites, but that at present, evidence for long-term benefit from adjunctivechemotherapy is meagre. Finally, it suggests some possible mechanisms which might heve limited the benefit of chemotherapy when added to radiation treatment. (Author). 87 refs.; 4 figs.; 4 tabs

  19. Incidental irradiation of internal mammary lymph nodes in breast cancer: conventional two-dimensional radiotherapy versus conformal three-dimensional radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Elton Trigo Teixeira; Ugino, Rafael Tsuneki; Lopes, Mauricio Russo; Pelosi, Edilson Lopes; Silva, Joao Luis Fernandes da, E-mail: eltontt@gmail.com [Hospital Sirio-Libanes, Sao paulo, SP (Brazil). Departamento de Radiologia e Oncologia; Santana, Marco Antonio; Ferreira, Denis Vasconcelos; Carvalho, Heloisa de Andrade [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Departamento de Radiologia e Oncologia

    2016-05-15

    Objective: to evaluate incidental irradiation of the internal mammary lymph nodes (IMLNs) through opposed tangential fields with conventional two-dimensional (2D) or three-dimensional (3D) radiotherapy techniques and to compare the results between the two techniques. Materials and Methods: This was a retrospective study of 80 breast cancer patients in whom radiotherapy of the IMLNs was not indicated: 40 underwent 2D radiotherapy with computed tomography for dosimetric control, and 40 underwent 3D radiotherapy. The total prescribed dose was 50.0 Gy or 50.4 Gy (2.0 or 1.8 Gy/day, respectively). We reviewed all plans and defined the IMLNs following the Radiation Therapy Oncology Group recommendations. For the IMLNs, we analyzed the proportion of the volume that received 45 Gy, the proportion of the volume that received 25 Gy, the dose to 95% of the volume, the dose to 50% of the volume, the mean dose, the minimum dose (Dmin), and the maximum dose (Dmax). Results: Left-sided treatments predominated in the 3D cohort. There were no differences between the 2D and 3D cohorts regarding tumor stage, type of surgery (mastectomy, breast-conserving surgery, or mastectomy with immediate reconstruction), or mean delineated IMLN volume (6.8 vs. 5.9 mL; p = 0.411). Except for the Dmin, all dosimetric parameters presented higher mean values in the 3D cohort (p < 0.05). The median Dmax in the 3D cohort was 50.34 Gy. However, the mean dose to the IMLNs was 7.93 Gy in the 2D cohort, compared with 20.64 Gy in the 3D cohort. Conclusion: Neither technique delivered enough doses to the IMLNs to achieve subclinical disease control. However, all of the dosimetric parameters were significantly higher for the 3D technique. (author)

  20. Chemotherapy and intensity modulated conformational radiotherapy for locally advanced pancreas cancers

    International Nuclear Information System (INIS)

    Huguet, F.; Wu, A.; Zhang, Z.; Winston, C.; Reidy, D.; Ho, A.; Allen, P.; Karyn, G.

    2011-01-01

    The authors report a retrospective study of the tolerance and survival of 48 patients who have been treated by a chemotherapy followed by a chemotherapy concomitant with an intensity-modulated radiotherapy for a locally advanced pancreas cancer. Results are discussed in terms of toxicity, cancer response, operability, survival rate. Tolerance is good. Local control rates, global survival rates and secondary resection rates are promising. Short communication

  1. Guidelines for the treatment of lung cancer using radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Michael J.; Novaes, Paulo Eduardo; Gadia, Rafael; Motta, Rodrigo [Sociedade Brasileira de Radioterapia (SBR), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The aim of this guideline is to evaluate the most appropriate radiotherapy technique to treat patients with lung cancer. Description of evidence collection method Through the elaboration of four relevant clinical questions related to the proposed theme, we sought to present the main evidences regarding safety, toxicity and effectiveness of the presented radiotherapy techniques. The study population consisted of male and female patients of all ages with lung cancer, regardless of histological type, staging or presence of comorbidities. For this, a systematic review of the literature was carried out in primary scientific databases (Medline – PubMed; Embase – Elsevier; Lilacs – Bireme; Cochrane Library – Record of Controlled Trials). All articles available through April 31, 2015 were considered. The search terms used in the research were: ((lung cancer) OR (lung carcinoma)) and (IMRT OR intensity modulation OR intensity modulated) and (conventional OR 2D OR two dimensional OR bidimensional OR standard OR conformal OR 3D OR tridimensional OR CRT OR three dimensional). The articles were selected based on critical evaluation using the instruments (scores) proposed by Jadad and Oxford. The references with greater degree of evidence were used. The recommendations were elaborated from discussions held with a drafting group composed of four members of the Brazilian Society of Radiotherapy. The guideline was reviewed by an independent group, which specializes in evidence-based clinical guidelines. After completion, the guideline was released for public consultation for 15 days, and the suggestions obtained were forwarded to the authors for evaluation and possible insertion in the final text. (author)

  2. Clinical considerations of Monte Carlo for electron radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Faddegon, Bruce; Balogh, Judith; Mackenzie, Robert; Scora, Daryl

    1998-01-01

    Technical requirements for Monte Carlo based electron radiotherapy treatment planning are outlined. The targeted overall accuracy for estimate of the delivered dose is the least restrictive of 5% in dose, 5 mm in isodose position. A system based on EGS4 and capable of achieving this accuracy is described. Experience gained in system design and commissioning is summarized. The key obstacle to widespread clinical use of Monte Carlo is lack of clinically acceptable measurement based methodology for accurate commissioning

  3. Evaluation of conformal radiotherapy techniques through physics and biologic criteria; Avaliacao de tecnicas radioterapicas conformacionais utilizando criterios fisicos e biologicos

    Energy Technology Data Exchange (ETDEWEB)

    Bloch, Jonatas Carrero

    2012-07-01

    In the fight against cancer, different irradiation techniques have been developed based on technological advances and aiming to optimize the elimination of tumor cells with the lowest damage to healthy tissues. The radiotherapy planning goal is to establish irradiation technical parameters in order to achieve the prescribed dose distribution over the treatment volumes. While dose prescription is based on radiosensitivity of the irradiated tissues, the physical calculations on treatment planning take into account dosimetric parameters related to the radiation beam and the physical characteristics of the irradiated tissues. To incorporate tissue's radiosensitivity into radiotherapy planning calculations can help particularize treatments and establish criteria to compare and elect radiation techniques, contributing to the tumor control and the success of the treatment. Accordingly, biological models of cellular response to radiation have to be well established. This work aimed to study the applicability of using biological models in radiotherapy planning calculations to aid evaluating radiotherapy techniques. Tumor control probability (TCP) was studied for two formulations of the linear-quadratic model, with and without repopulation, as a function of planning parameters, as dose per fraction, and of radiobiological parameters, as the α/β ratio. Besides, the usage of biological criteria to compare radiotherapy techniques was tested using a prostate planning simulated with Monte Carlo code PENELOPE. Afterwards, prostate planning for five patients from the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, USP, using three different techniques were compared using the tumor control probability. In that order, dose matrices from the XiO treatment planning system were converted to TCP distributions and TCP-volume histograms. The studies performed allow the conclusions that radiobiological parameters can significantly influence tumor control

  4. Role of radiotherapy in the treatment of meningiomas

    International Nuclear Information System (INIS)

    Noel, G.; Renard, A.; Mazeron, J.J.; Valery, C.; Mokhtari, K.

    2001-01-01

    Role of radiotherapy in the treatment of meningiomas. Cerebral meningiomas account for 15-20% of all cerebral tumours. Although seldom malignant, they frequently recur in spite of complete surgery, which remains the cornerstone of the treatment. In order to decrease the probability of local recurrence, radiotherapy has often been recommended in atypical or malignant meningioma as well as in benign meningioma which was incompletely resected. However, this treatment never was the subject of prospective studies, randomized or not. The purpose of this review of the literature was to give a progress report on the results of different published series in the field of methodology as well as in the techniques of radiotherapy. Proposals for a therapeutic choice are made according to this analysis. For grade I or grade II-III meningiomas, limits of gross tumor volume (GTV) include the tumour in place or the residual tumour after surgery; clinical target volume (CTV) limits include gross tumour volume before surgery with a GTV-CTV distance of 1 and 2 cm respectively. Delivered doses are 55 Gy into CTV and 55-60 Gy and 70 Gy into GTV for grade I and grade II-III meningiomas respectively. (authors)

  5. Estimate of the damage in organs induced by neutrons in three-dimensional conformal radiotherapy; Estimacion del dano en organos inducido por neutrones en radioterapia conformada en 3D

    Energy Technology Data Exchange (ETDEWEB)

    Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Servicio de Seguridad Radiologica, Calzada de la Cruz 118 sur, 63000 Tepic, Nayarit (Mexico); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Uribe, M. del R., E-mail: jlbenitesr@prodigy.net.mx [Instituto Tecnico Superior de Radiologia, Calle Leon No. 129, 63000 Tepic, Nayarit (Mexico)

    2014-08-15

    By means of Monte Carlo methods was considered the damage in the organs, induced by neutrons, of patients with cancer that receive treatment in modality of three-dimensional conformal radiotherapy (3D-CRT) with lineal accelerator Varian Ix. The objective of this work was to estimate the damage probability in radiotherapy patients, starting from the effective dose by neutrons in the organs and tissues out of the treatment region. For that a three-dimensional mannequin of equivalent tissue of 30 x 100 x 30 cm{sup 3} was modeled and spherical cells were distributed to estimate the Kerma in equivalent tissue and the absorbed dose by neutrons. With the absorbed dose the effective dose was calculated using the weighting factors for the organ type and radiation type. With the effective dose and the damage factors, considered in the ICRP 103, was considered the probability of damage induction in organs. (Author)

  6. Sucralfate versus mesalazine versus hydrocortisone in the prevention of acute radiation proctitis during conformal radiotherapy for prostate carcinoma. A randomized study

    International Nuclear Information System (INIS)

    Sanguineti, G.; Franzone, P.; Marcenaro, M.; Vitale, V.; Foppiano, F.

    2003-01-01

    Purpose: To assess whether the topical use of steroids or 5-aminosalicylic acid (5-ASA) is superior to sucralfate in preventing acute rectal toxicity during three-dimensional conformal radiotherapy (3DCRT) to 76 Gy. Patients and Methods: Patients undergoing 3DCRT for prostate carcinoma at our institution were offered to be randomized to sucralfate 3 g in 15 ml suspension enema (Antepsin trademark ), mesalazine 4 g gel enema (Enterasyn trademark), or hydrocortisone 100 mg foam enema (Colifoam trademark ). Randomization was blind to the treating physician but not to the patient. Sucralfate was chosen as control arm. Topical treatment had to be performed once daily, starting on day 1 of 3DCRT. Acute rectal toxicity was scored weekly according to RTOG criteria. Time to occurrence of grade 2+ acute rectal toxicity was taken as endpoint. Results: The trial was opened in August 1999, and after the first 24 patients had been treated, arm 2 was discontinued because of eight patients receiving mesalazine, seven actually developed acute rectal toxicity (five patients grade 3 and two patients grade 2). Until May 2001, 134 consecutive patients were randomly assigned to sucralfate (63 patients), mesalazine (eight patients) or hydrocortisone (63 patients). The cumulative incidence of acute rectal toxicity at the end of treatment by arm is 61.9 ± 6.1%, 87.5 ± 11.7%, and 52.4 ± 6.2% for arms 1, 2, and 3, respectively. The difference between the mesalazine group and the sucralfate group is highly significant (hazard ratio [HR] 2.5, 95% confidence interval [CI] 1.1-5.7; p = 0.03). At both uni- and multivariate analysis taking into account several patients and treatment covariates, the difference between hydrocortisone and sucralfate is not significant (HR 0.7, 95% CI 0.5-1.2; p = 0.2). Conclusion: Topical mesalazine is contraindicated during radiotherapy. Hydrocortisone enema is not superior to sucralfate in preventing acute rectal toxicity. (orig.)

  7. Sucralfate versus mesalazine versus hydrocortisone in the prevention of acute radiation proctitis during conformal radiotherapy for prostate carcinoma. A randomized study.

    Science.gov (United States)

    Sanguineti, Giuseppe; Franzone, Paola; Marcenaro, Michela; Foppiano, Franca; Vitale, Vito

    2003-07-01

    To assess whether the topical use of steroids or 5-aminosalicylic acid (5-ASA) is superior to sucralfate in preventing acute rectal toxicity during three-dimensional conformal radiotherapy (3DCRT) to 76 Gy. Patients undergoing 3DCRT for prostate carcinoma at our institution were offered to be randomized to sucralfate 3 g in 15 ml suspension enema (Antepsin, mesalazine 4 g gel enema (Enterasyn, or hydrocortisone 100 mg foam enema (Colifoam. Randomization was blind to the treating physician but not to the patient. Sucralfate was chosen as control arm. Topical treatment had to be performed once daily, starting on day 1 of 3DCRT. Acute rectal toxicity was scored weekly according to RTOG criteria. Time to occurrence of grade 2+ acute rectal toxicity was taken as endpoint. The trial was opened in August 1999, and after the first 24 patients had been treated, arm 2 was discontinued because of eight patients receiving mesalazine, seven actually developed acute rectal toxicity (five patients grade 3 and two patients grade 2). Until May 2001, 134 consecutive patients were randomly assigned to sucralfate (63 patients), mesalazine (eight patients) or hydrocortisone (63 patients). The cumulative incidence of acute rectal toxicity at the end of treatment by arm is 61.9 +/- 6.1%, 87.5 +/- 11.7%, and 52.4 +/- 6.2% for arms 1, 2, and 3, respectively. The difference between the mesalazine group and the sucralfate group is highly significant (hazard ratio [HR] 2.5, 95% confidence interval [CI] 1.1-5.7; p = 0.03). At both uni- and multivariate analysis taking into account several patients and treatment covariates, the difference between hydrocortisone and sucralfate is not significant (HR 0.7, 95% CI 0.5-1.2; p = 0.2). Topical mesalazine is contraindicated during radiotherapy. Hydrocortisone enema is not superior to sucralfate in preventing acute rectal toxicity.

  8. Sucralfate versus mesalazine versus hydrocortisone in the prevention of acute radiation proctitis during conformal radiotherapy for prostate carcinoma. A randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Sanguineti, G.; Franzone, P.; Marcenaro, M.; Vitale, V. [Dept. of Radiation Oncology, National Inst. for Cancer Research, Genova (Italy); Foppiano, F. [Dept. of Physics, National Inst. for Cancer Research, Genova (Italy)

    2003-07-01

    Purpose: To assess whether the topical use of steroids or 5-aminosalicylic acid (5-ASA) is superior to sucralfate in preventing acute rectal toxicity during three-dimensional conformal radiotherapy (3DCRT) to 76 Gy. Patients and Methods: Patients undergoing 3DCRT for prostate carcinoma at our institution were offered to be randomized to sucralfate 3 g in 15 ml suspension enema (Antepsin {sup trademark}), mesalazine 4 g gel enema (Enterasyn trademark), or hydrocortisone 100 mg foam enema (Colifoam {sup trademark}). Randomization was blind to the treating physician but not to the patient. Sucralfate was chosen as control arm. Topical treatment had to be performed once daily, starting on day 1 of 3DCRT. Acute rectal toxicity was scored weekly according to RTOG criteria. Time to occurrence of grade 2+ acute rectal toxicity was taken as endpoint. Results: The trial was opened in August 1999, and after the first 24 patients had been treated, arm 2 was discontinued because of eight patients receiving mesalazine, seven actually developed acute rectal toxicity (five patients grade 3 and two patients grade 2). Until May 2001, 134 consecutive patients were randomly assigned to sucralfate (63 patients), mesalazine (eight patients) or hydrocortisone (63 patients). The cumulative incidence of acute rectal toxicity at the end of treatment by arm is 61.9 {+-} 6.1%, 87.5 {+-} 11.7%, and 52.4 {+-} 6.2% for arms 1, 2, and 3, respectively. The difference between the mesalazine group and the sucralfate group is highly significant (hazard ratio [HR] 2.5, 95% confidence interval [CI] 1.1-5.7; p = 0.03). At both uni- and multivariate analysis taking into account several patients and treatment covariates, the difference between hydrocortisone and sucralfate is not significant (HR 0.7, 95% CI 0.5-1.2; p = 0.2). Conclusion: Topical mesalazine is contraindicated during radiotherapy. Hydrocortisone enema is not superior to sucralfate in preventing acute rectal toxicity. (orig.)

  9. The early toxicity of escalated versus standard dose conformal radiotherapy with neo-adjuvant androgen suppression for patients with localised prostate cancer: Results from the MRC RT01 trial (ISRCTN47772397)

    International Nuclear Information System (INIS)

    Dearnaley, David P.; Sydes, Matthew R.; Langley, Ruth E.; Graham, John D.; Huddart, Robert A.; Syndikus, Isabel; Matthews, John H.L.; Scrase, Christopher D.; Jose, Chakiath C.; Logue, John; Stephens, Richard J.

    2007-01-01

    Background: Five-year disease-free survival rates for localised prostate cancer following standard doses of conventional radical external beam radiotherapy are around 80%. Conformal radiotherapy (CFRT) raises the possibility that radiotherapy doses can be increased and long-term efficacy outcomes improved, with safety an important consideration. Methods: MRC RT01 is a randomised controlled trial of 862 men with localised prostate cancer comparing Standard CFRT (64 Gy/32 f) versus Escalated CFRT (74 Gy/37 f), both administered with neo-adjuvant androgen suppression. Early toxicity was measured using physician-reported instruments (RTOG, LENT/SOM, Royal Marsden Scales) and patient-reported questionnaires (MOS SF-36, UCLA Prostate Cancer Index, FACT-P). Results: Overall early radiotherapy toxicity was similar, apart from increased bladder, bowel and sexual toxicity, in the Escalated Group during a short immediate post-radiotherapy period. Toxicity in both groups had abated by week 12. Using RTOG Acute Toxicity scores, cumulative Grade ≥2 bladder and bowel toxicity was 38% and 30% for Standard Group and 39% and 33% in Escalated Group, respectively. Urinary frequency (Royal Marsden Scale) improved in both groups from pre-androgen suppression to 6 months post-radiotherapy (p < 0.001), but bowel and sexual functioning deteriorated. This pattern was supported by patient-completed assessments. Six months after starting radiotherapy the incidence of RTOG Grade ≥2 side-effects was low (<1%); but there were six reports of rectal ulceration (6 Escalated Group), six haematuria (5 Escalated Group) and eight urethral stricture (6 Escalated Group). Conclusions: The two CFRT schedules with neo-adjuvant androgen suppression have broadly similar early toxicity profiles except for the immediate post-RT period. At 6 months and compared to before hormone therapy, bladder symptoms improved, whereas bowel and sexual symptoms worsened. These assessments of early treatment safety will be

  10. Radiotherapy professionals faced with the obligation of treatments safety improvement

    International Nuclear Information System (INIS)

    2011-01-01

    The occurrence of a major accident in Epinal (2006), followed by one in Toulouse (2007), led the Ministry of Health to mobilize the whole actors in radiotherapy in order to define national measures intended to improve health care security. Compiled in the so-called 'road map', these measures were presented in November 2007, and implemented in the 2009-2013 cancer programme. The French Institute for Radiological Protection and Nuclear Safety (IRSN) undertook a study aiming at assessing the effects of the above-mentioned measures on organization and safety management of radiotherapy facilities, but also on treatment achievement procedures and health professionals. More specifically, IRSN sought to examine the ability of health professionals to take into account new safety demands and to adapt their practices accordingly. With these purposes objectives, a qualitative study using the methods of ergonomics and sociology of organizations was completed in 2009-2010. The results of the study presented in this report show an effective improvement of health care safety along with a variable integration of safety measures depending on radiotherapy facilities and units. In particular, integration depends on 1) the governance mode of the health care facility, more or less conducive to promoting safety, 2) the pre-existence of a safety culture and safety organization, and 3) the facility commitment to health care safety improvement actions. The study also reveals that the implementation of new safety demands and the changes they involve create new constraints, which put pressure on health professionals and may threaten the durability of the improvements made. In order to facilitate the appropriation and implementation by radiotherapy units of the measures meant to improve health care safety, IRSN identifies 6 lines of thought: - strengthen coordination between institutional actors in order to ensure the consistency of the requests addressed to the facilities and limit their

  11. Normal tissue complication probabilities correlated with late effects in the rectum after prostate conformal radiotherapy

    International Nuclear Information System (INIS)

    Dale, Einar; Olsen, Dag R.; Fossa, Sophie D.

    1999-01-01

    Purpose: Radiation therapy of deep-sited tumours will always result in normal tissue doses to some extent. The aim of this study was to calculate different risk estimates of late effects in the rectum for a group of cancer prostate patients treated with conformal radiation therapy (CRT) and correlate these estimates with the occurrences of late effects. Since the rectum is a hollow organ, several ways of generating dose-volume distributions over the organ are possible, and we wanted to investigate two of them. Methods and Materials: A mathematical model, known as the Lyman-Kutcher model, conventionally used to estimate normal tissue complication probabilities (NTCP) associated with radiation therapy, was applied to a material of 52 cancer prostate patients. The patients were treated with a four field box technique, with the rectum as organ at risk. Dose-volume histograms (DVH) were generated for the whole rectum (including the cavity) and of the rectum wall. One to two years after the treatment, the patients completed a questionnaire concerning bowel (rectum) related morbidity quantifying the extent of late effects. Results: A correlation analysis using Spearman's rank correlation coefficient, for NTCP values calculated from the DVHs and the patients' scores, gave correlation coefficients which were not statistically significant at the p max , of the whole rectum, correlated better to observed late toxicity than D max derived from histograms of the rectum wall. Correlation coefficients from 'high-dose' measures were larger than those calculated from the NTCP values. Accordingly, as the volume parameter of the Lyman-Kutcher model was reduced, raising the impact of small high-dose volumes on the NTCP values, the correlation between observed effects and NTCP values became significant at p < 0.01 level. Conclusions: 1) High-dose levels corresponding to small volume fractions of the cumulative dose-volume histograms were best correlated with the occurrences of late

  12. Conformal radiotherapy to 76 Gy in localized prostate cancer. Therapeutic modalities and preliminary results

    International Nuclear Information System (INIS)

    Pontvert, D.; Mammar, H.; Flam, T.; Debre, B.; Thiounn, N.; Gaboriaud, G.; Jourdan-Da Silvae, N.; Beuzeboc, P.

    2008-01-01

    Purpose: to describe therapeutic modalities for localized prostate cancer treated by conformal radiation to 76 Gy with or without androgen ablation. To evaluate the preliminary results in terms of survival, biological control and toxicity. Patients and method: between January 1998 and June 2001, 321 patients with localized prostate cancer were irradiated at Institut Curie. Tumors were stratified into the three Memorial Sloan-Kettering Cancer Center prognostic groups (1998) for analysis: favorable risk group (F.G.) 23%, intermediate risk group (I.G.) 36.5%, unfavorable risk group (U.G.) 40.5%. Androgen deprivation, mainly neo-adjuvant, less or equal to one year was prescribed to 93.8% of patients (72.6% less or equal to six months). Planning target volume prescription doses were: prostate: 76 Gy, seminal vesicles: 56 to 76 Gy, and pelvic lymph nodes: 44 Gy to 16.8% of patients. Results: the five-year actuarial overall survival was 94% (95% I.C.: 90-97%). The median post-therapeutic follow-up was 36 months (nine to 60 months). The 48-month actuarial rates of biochemical control for the three prognostic groups were statistically different according to both the American Society for Therapeutic Radiology and Oncology consensus (A.S.T.R.O. 1997) and the Fox Chase Cancer Center definitions of biochemical failure (F.C.C.C. 2000) with respectively 87 and 94% for F.G., 78 and 84% for I.G., 54 and 58% for U.G. (P < 10-6 and P < 10-8). At time of our analysis, late post-treatment rectal and bladder bleedings were 17,4 and 13,6%, respectively. According to a 1-4 scale adapted from M.D. Anderson Cancer Center criteria: rectal bleedings were grade 1 (9.6%), grade 2 (6.2%) and grade 3 (1.6%). Bladder bleedings were grade 2 (13%) and grade 3 (0.6%). Analysis of rectal bleeding risk factors showed significant correlations with pelvic lymph nodes irradiation for grade 2 and 3, (P = 0.02), and for all grades, a correlation with smaller rectal wall volumes (P = 0.03), and greater

  13. Potency probability following conformal megavoltage radiotherapy using conventional doses for localized prostate cancer

    International Nuclear Information System (INIS)

    Mantz, C.A.; Song, P.; Farhangi, E.; Nautiyal, J.; Awan, A.; Ignacio, L.; Weichselbaum, R.; Vijayakumar, S.

    1997-01-01

    Purpose: Impotence is a familiar sequela of definitive external beam radiation therapy (EBRT) for localized prostate cancer; however, nerve-sparing radical prostatectomy (NSRP) has offered potency rates as high as 70% for selected for patients in several large series. To the authors' knowledge, age and stage-matched comparisons between the effects of EBRT and NSRP upon the normal age trend of impotence have not been performed. Herein, we report the change in potency over time in an EBRT-treated population, determine the significantly predisposing health factors affecting potency in this population, and compare age and stage-matched potency rates with those of normal males and prostatectomy patients. Methods and Materials: Our results are obtained from a retrospective study of 114 patients ranging in age from 52 to 85 (mean, 68) who were diagnosed with clinical stages A-C C (T1-T4N0M0) prostate cancer and then treated conformally with megavoltage x-rays to 6500-7000 cGy (180-200 cGy per fraction) using the four-field box technique. Information concerning pre-RT potency, medical and surgical history, and medications was documented for each patient as was time of post-RT change in potency during regular follow-up. The median follow-up time was 18.5 months. Results: The actuarial probability of potency for all patients gradually decreased throughout post-RT follow-up. At months 1, 12, 24, and 36, potency rates were 98, 92, 75, and 66%, respectively. For those patients who became impotent, the median time to impotence was 14 months. Factors identified from logistic regression analysis as significant predictors of post-EBRT impotence include pre-EBRT partial potency (p < 0.001), vascular disease (p < 0.001), and diabetes (p = 0.003). Next, an actuarial plot of potency probability to patient age for the EBRT-treated population was compared to that obtained from the Massachusetts Male Aging Study of normal males. The two curves were not significantly different (logrank

  14. Assessment of renal function after conformal radiotherapy and intensity-modulated radiotherapy by functional {sup 1}H-MRI and {sup 23}Na-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Haneder, S.; Michaely, H.J.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Heidelberg Univ., Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Konstandin, S.; Schad, L.R. [Universitaetsmedizin Mannheim, Heidelberg Univ., Mannheim (Germany). Computer-Assisted Clinical Medicine; Siebenlist, K.; Wertz, H.; Wenz, F.; Lohr, F.; Boda-Heggemann, J. [Universitaetsmedizin Mannheim, Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology

    2012-12-15

    Purpose: Adjuvant radiochemotherapy (RCHT) improves survival of patients with locally advanced gastric cancer. Conventional three-dimensional conformal radiotherapy (3D-CRT) results in ablative doses to a significant amount of the left kidney, while image-guided intensity-modulated radiotherapy (IG-IMRT) provides excellent target coverage with improved kidney sparing. Few long-term results on IMRT for gastric cancer, however, have been published. Functional magnetic resonance imaging (fMRI) at 3.0 T including blood oxygenation-level dependent (BOLD) imaging, diffusion-weighted imaging (DWI) and, for the first time, {sup 23}Na imaging was used to evaluate renal status after radiotherapy with 3D-CRT or IG-IMRT. Patients and methods Four disease-free patients (2 after 3D-CRT and 2 after IMRT; FU for all patients > 5 years) were included in this feasibility study. Morphological sequences, axial DWI images, 2D-gradient echo (GRE)-BOLD images, and {sup 23}Na images were acquired. Mean values/standard deviations for ({sup 23}Na), the apparent diffusion coefficient (ADC), and R2{sup *} values were calculated for the upper/middle/lower parts of both kidneys. Corticomedullary {sup 23}Na-concentration gradients were determined. Results: Surprisingly, IG-IMRT patients showed no morphological alterations and no statistically significant differences of ADC and R2{sup *} values in all renal parts. Values for mean corticomedullary {sup 23}Na-concentration matched those for healthy volunteers. Results were similar in 3D-CRT patients, except for the cranial part of the left kidney. This was atrophic and presented significantly reduced functional parameters (p = 0.001 - p = 0.033). Reduced ADC values indicated reduced cell density and reduced extracellular space. Cortical and medullary R2{sup *} values of the left cranial kidney in the 3D-CRT group were higher, indicating more deoxygenated hemoglobin due to reduced blood flow/oxygenation. ({sup 23}Na) of the renal cranial parts in

  15. External validation of three dimensional conformal radiotherapy based NTCP models for patient-rated xerostomia and sticky saliva among patients treated with intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Beetz, Ivo; Schilstra, Cornelis; Luijk, Peter van; Christianen, Miranda E.M.C.; Doornaert, Patricia; Bijl, Henk P.; Chouvalova, Olga; Heuvel, Edwin R. van den; Steenbakkers, Roel J.H.M.; Langendijk, Johannes A.

    2012-01-01

    Purpose: The purpose of this study was to investigate the ability of predictive models for patient-rated xerostomia (XER 6M ) and sticky saliva (STIC 6M ) at 6 months after completion of primary (chemo)radiation developed in head and neck cancer patients treated with 3D-conformal radiotherapy (3D-CRT) to predict outcome in patients treated with intensity modulated radiotherapy (IMRT). Methods and materials: Recently, we published the results of a prospective study on predictive models for patient-rated xerostomia and sticky saliva in head and neck cancer patients treated with 3D-CRT (3D-CRT based NTCP models). The 3D-CRT based model for XER 6M consisted of three factors, including the mean parotid dose, age, and baseline xerostomia (none versus a bit). The 3D-CRT based model for STIC 6M consisted of the mean submandibular dose, age, the mean sublingual dose, and baseline sticky saliva (none versus a bit). In the current study, a population consisting of 162 patients treated with IMRT was used to test the external validity of these 3D-CRT based models. External validity was described by the explained variation (R 2 Nagelkerke) and the Brier score. The discriminative abilities of the models were calculated using the area under the receiver operating curve (AUC) and calibration (i.e. the agreement between predicted and observed outcome) was assessed with the Hosmer–Lemeshow “goodness-of-fit” test. Results: Overall model performance of the 3D-CRT based predictive models for XER 6M and STIC 6M was significantly worse in terms of the Brier score and R 2 Nagelkerke among patients treated with IMRT. Moreover the AUC for both 3D-CRT based models in the IMRT treated patients were markedly lower. The Hosmer–Lemeshow test showed a significant disagreement for both models between predicted risk and observed outcome. Conclusion: 3D-CRT based models for patient-rated xerostomia and sticky saliva among head and neck cancer patients treated with primary radiotherapy or

  16. Assessment of renal function after conformal radiotherapy and intensity-modulated radiotherapy by functional 1H-MRI and 23Na-MRI

    International Nuclear Information System (INIS)

    Haneder, S.; Michaely, H.J.; Schoenberg, S.O.; Konstandin, S.; Schad, L.R.; Siebenlist, K.; Wertz, H.; Wenz, F.; Lohr, F.; Boda-Heggemann, J.

    2012-01-01

    Purpose: Adjuvant radiochemotherapy (RCHT) improves survival of patients with locally advanced gastric cancer. Conventional three-dimensional conformal radiotherapy (3D-CRT) results in ablative doses to a significant amount of the left kidney, while image-guided intensity-modulated radiotherapy (IG-IMRT) provides excellent target coverage with improved kidney sparing. Few long-term results on IMRT for gastric cancer, however, have been published. Functional magnetic resonance imaging (fMRI) at 3.0 T including blood oxygenation-level dependent (BOLD) imaging, diffusion-weighted imaging (DWI) and, for the first time, 23 Na imaging was used to evaluate renal status after radiotherapy with 3D-CRT or IG-IMRT. Patients and methods Four disease-free patients (2 after 3D-CRT and 2 after IMRT; FU for all patients > 5 years) were included in this feasibility study. Morphological sequences, axial DWI images, 2D-gradient echo (GRE)-BOLD images, and 23 Na images were acquired. Mean values/standard deviations for ( 23 Na), the apparent diffusion coefficient (ADC), and R2 * values were calculated for the upper/middle/lower parts of both kidneys. Corticomedullary 23 Na-concentration gradients were determined. Results: Surprisingly, IG-IMRT patients showed no morphological alterations and no statistically significant differences of ADC and R2 * values in all renal parts. Values for mean corticomedullary 23 Na-concentration matched those for healthy volunteers. Results were similar in 3D-CRT patients, except for the cranial part of the left kidney. This was atrophic and presented significantly reduced functional parameters (p = 0.001 - p = 0.033). Reduced ADC values indicated reduced cell density and reduced extracellular space. Cortical and medullary R2 * values of the left cranial kidney in the 3D-CRT group were higher, indicating more deoxygenated hemoglobin due to reduced blood flow/oxygenation. ( 23 Na) of the renal cranial parts in the 3D-CRT group was significantly reduced

  17. Dosimetric Comparison Between Intensity-Modulated with Coplanar Field and 3D Conformal Radiotherapy with Noncoplanar Field for Postocular Invasion Tumor

    International Nuclear Information System (INIS)

    Tu Wenyong; Liu Lu; Zeng Jun; Yin Weidong; Li Yun

    2010-01-01

    This study presents a dosimetric optimization effort aiming to compare noncoplanar field (NCF) on 3 dimensions conformal radiotherapy (3D-CRT) and coplanar field (CF) on intensity-modulated radiotherapy (IMRT) planning for postocular invasion tumor. We performed a planning study on the computed tomography data of 8 consecutive patients with localized postocular invasion tumor. Four fields NCF 3D-CRT in the transverse plane with gantry angles of 0-10 deg., 30-45 deg., 240-270 deg., and 310-335 deg. degrees were isocentered at the center of gravity of the target volume. The geometry of the beams was determined by beam's eye view. The same constraints were prepared with between CF IMRT optimization and NCF 3D-CRT treatment. The maximum point doses (D max) for the different optic pathway structures (OPS) with NCF 3D-CRT treatment should differ in no more than 3% from those with the NCF IMRT plan. Dose-volume histograms (DVHs) were obtained for all targets and organ at risk (OAR) with both treatment techniques. Plans with NCF 3D-CRT and CF IMRT constraints on target dose in homogeneity were computed, as well as the conformity index (CI) and homogeneity index (HI) in the target volume. The PTV coverage was optimal with both NCF 3D-CRT and CF IMRT plans in the 8 tumor sites. No difference was noted between the two techniques for the average D max and D min dose. NCF 3D-CRT and CF IMRT will yield similar results on CI. However, HI was a significant difference between NCF 3D-CRT and CF IMRT plan (p < 0.001). Physical endpoints for target showed the mean target dose to be low in the CF IMRT plan, caused by a large target dose in homogeneity (p < 0.001). The impact of NCF 3D-CRT versus CF IMRT set-up is very slight. NCF3D-CRT is one of the treatment options for postocular invasion tumor. However, constraints for OARs are needed.

  18. Dosimetry study on the conventional and three dimensional conformal radiation treatment planning protocols for rectal cancer

    International Nuclear Information System (INIS)

    Cai Yong; He Yuxiang; Han Shukui; Wu Hao; Gong Jian; Xu Bo

    2007-01-01

    Objective: To compare the dose distribution of clinical target volume (CTV), in normal tissues and organs for patients with rectal cancer on the conventional radiotherapy (2D) and three dimension- al conformal radiation treatment (3DCRT). Methods: The CT image data of 36 rectal cancer patients treated with 3DCRT were studied. The CTV, small bowel, colon, bladder, pelvic bone marrow, and femoral head and neck were contoured on consecutive axial slices of CT images. Two 3DCRT and three conventional treatment planning protocols were simulated using three dimensional treatment planning system (CMS Focus 2.31), were defined as 3D-3, 3D-4, 2D-2, 2D-3, 2D-4. The difference of five treatment planning protocols on the CTV and normal structure by analysis of dose-volume histograms (DVHs) were compared. Results: The D 95 and V 95 of these five protocols all exceeded 97%. The conformity index(CI) of 3D was obviously larger than that of 2D protocol. The dose inhomogeneity(DI) in 4 DCRT was less than that of 3 DCRT. The 3D as compared with the 2D, significantly reduced the mean dose of 45 Gy to the small bowel and colon. The 3D-3 as compared with the 2D-3, the 3D-4 as compared with the 2D-4, the mean dose of small bowel and colon was reduced by 28.5% and 25.7%, respectively. The 3D-3 as compared with the 2D-2, the 3D-3 as compared with the 2D-3 and the 3D4 as compared with the 2D-4, the percentage volume of small bowel and colon which received 45 Gy was reduced by 80.8% , 51.1% and 54.7% , respectively. Either the mean dose, or the percentage volume receiving 35 Gy and 45 Gy to the pelvic bone and bladder, the 3D planning protocols had advanage over the 2D planning protocols. The V 45 of bladder in 2D-2 planning proto- col was the highest in all planning protocols, exceeding 98%, but the highest V 45 of bladder was only 50% in the other planning protocols. Conclusions: Even though the difference in pelvic CTV of rectal cancer patients between the conventional radiotherapy and 3

  19. Process evaluation of treatment times in a large radiotherapy department

    International Nuclear Information System (INIS)

    Beech, R.; Burgess, K.; Stratford, J.

    2016-01-01

    Purpose/objective: The Department of Health (DH) recognises access to appropriate and timely radiotherapy (RT) services as crucial in improving cancer patient outcomes, especially when facing a predicted increase in cancer diagnosis. There is a lack of ‘real-time’ data regarding daily demand of a linear accelerator, the impact of increasingly complex techniques on treatment times, and whether current scheduling reflects time needed for RT delivery, which would be valuable in highlighting current RT provision. Material/methods: A systematic quantitative process evaluation was undertaken in a large regional cancer centre, including a satellite centre, between January and April 2014. Data collected included treatment room-occupancy time, RT site, RT and verification technique and patient mobility status. Data was analysed descriptively; average room-occupancy times were calculated for RT techniques and compared to historical standardised treatment times within the department. Results: Room-occupancy was recorded for over 1300 fractions, over 50% of which overran their allotted treatment time. In a focused sample of 16 common techniques, 10 overran their allocated timeslots. Verification increased room-occupancy by six minutes (50%) over non-imaging. Treatments for patients requiring mobility assistance took four minutes (29%) longer. Conclusion: The majority of treatments overran their standardised timeslots. Although technique advancement has reduced RT delivery time, room-occupancy has not necessarily decreased. Verification increases room-occupancy and needs to be considered when moving towards adaptive techniques. Mobility affects room-occupancy and will become increasingly significant in an ageing population. This evaluation assesses validity of current treatment times in this department, and can be modified and repeated as necessary. - Highlights: • A process evaluation examined room-occupancy for various radiotherapy techniques. • Appointment lengths

  20. Treatment of Sarcoma Lung Metastases with Stereotactic Body Radiotherapy

    Directory of Open Access Journals (Sweden)

    Adam D. Lindsay

    2018-01-01

    Full Text Available Background. The most common site of sarcoma metastasis is the lung. Surgical resection of pulmonary metastases and chemotherapy are treatment options that have been employed, but many patients are poor candidates for these treatments for multiple host or tumor-related reasons. In this group of patients, radiation might provide a less morbid treatment alternative. We sought to evaluate the efficacy of radiotherapy in the treatment of metastatic sarcoma to the lung. Methods. Stereotactic body radiotherapy (SBRT was used to treat 117 pulmonary metastases in 44 patients. Patients were followed with serial computed tomography imaging of the chest. The primary endpoint was failure of control of a pulmonary lesion as measured by continued growth. Radiation-associated complications were recorded. Results. The majority of patients (84% received a total dose of 50 Gy per metastatic nodule utilizing an image-guided SBRT technique. The median interval follow-up was 14.2 months (range 1.6–98.6 months. Overall survival was 82% at two years and 50% at five years. Of 117 metastatic nodules treated, six nodules showed failure of treatment (95% control rate. Twenty patients (27% developed new metastatic lesions and underwent further SBRT. The side effects of SBRT included transient radiation pneumonitis n=6, cough n=2, rib fracture n=1, chronic pain n=1, dermatitis n=1, and dyspnea n=1. Conclusion. Stereotactic body radiotherapy is an effective and safe treatment for the ablation of pulmonary metastasis from sarcoma. Further work is needed to evaluate the optimal role of SBRT relative to surgery or chemotherapy for treatment of metastatic sarcoma.

  1. Electron Density Calibration for Radiotherapy Treatment Planning

    International Nuclear Information System (INIS)

    Herrera-Martinez, F.; Rodriguez-Villafuerte, M.; Martinez-Davalos, A.; Ruiz-Trejo, C.; Celis-Lopez, M. A.; Larraga-Gutierrez, J. M.; Garcia-Garduno, A.

    2006-01-01

    Computed tomography (CT) images are used as basic input data for most modern radiosurgery treatment planning systems (TPS). CT data not only provide anatomic information to delineate target volumes, but also allow the introduction of corrections for tissue inhomogeneities into dose calculations during the treatment planning procedure. These corrections involve the determination of a relationship between tissue electron density (ρe) and their corresponding Hounsfield Units (HU). In this work, an elemental analysis of different commercial tissue equivalent materials using Scanning Electron Microscopy was carried out to characterize their chemical composition. The tissue equivalent materials were chosen to ensure a large range of ρe to be included in the CT scanner calibration. A phantom was designed and constructed with these materials to simulate the size of a human head

  2. Treatment of intractable cancer by radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Abe, M [Kyoto Univ. (Japan). Faculty of Medicine

    1981-07-01

    Intraoperative irradiation, thermotherapy, hypoxic cell sensitizer, and neutron brachytherapy were used for locally advanced cancer and value and limitations of these therapies were discussed. Intraoperative irradiation was mainly used for cancers of the gastro-intestinal tract. In stage I gastric cancers, no difference in the five-year survival rates was found between the groups with and without intraoperative irradiation. In gastric cancers of stage II or more, intraoperative irradiation had a favourable effect. Thermotherapy was applied to superficial radio-resistant cancer by the use of a thermal system of microwave- and radio-frequency heating. This treatment induced disappearance of approximately 50% of tumor. For the treatment with hypoxic cell sensitizer, studies of phase I and II with Misonidazole were conducted; from these results, the protocol was made for phase III study of esophagus cancer, lung cancer, head and neck cancer, uterus cancer, and brain cancer. Brachytherapy using /sup 252/Cf was also developed for locally advanced cancer.

  3. Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms

    International Nuclear Information System (INIS)

    Boersma, Liesbeth J.; Brink, Mandy van den; Bruce, Allison M.; Shouman, Tarek; Gras, Luuk; Velde, Annet te; Lebesque, Joos V.

    1998-01-01

    Purpose: To investigate whether Dose-Volume Histogram (DVH) parameters can be used to identify risk groups for developing late gastrointestinal (GI) and genitourinary (GU) complications after conformal radiotherapy for prostate cancer. Methods and Materials: DVH parameters were analyzed for 130 patients with localized prostate cancer, treated with conformal radiotherapy in a dose-escalating protocol (70-78 Gy, 2 Gy per fraction). The incidence of late (>6 months) GI and GU complications was classified using the RTOG/EORTC and the SOMA/LENT scoring system. In addition, GI complications were divided in nonsevere and severe (requiring one or more laser treatments or blood transfusions) rectal bleeding. The median follow-up time was 24 months. We investigated whether rectal and bladder wall volumes, irradiated to various dose levels, correlated with the observed actuarial incidences of GI and GU complications, using volume as a continuous variable. Subsequently, for each dose level in the DVH, the rectal wall volumes were dichotomized using different volumes as cutoff levels. The impact of the total radiation dose, and the maximum radiation dose in the rectal and bladder wall was analyzed as well. Results: The actuarial incidence at 2 years for GI complications ≥Grade II was 14% (RTOG/EORTC) or 20% (SOMA/LENT); for GU complications ≥Grade III 8% (RTOG/EORTC) or 21% (SOMA/LENT). Neither for GI complications ≥Grade II (RTOG/EORTC or SOMA/LENT), nor for GU complications ≥Grade III (RTOG/EORTC or SOMA/LENT), was a significant correlation found between any of the DVH parameters and the actuarial incidence of complications. For severe rectal bleeding (actuarial incidence at 2 years 3%), four consecutive volume cutoff levels were found, which significantly discriminated between high and low risk. A trend was observed that a total radiation dose ≥ 74 Gy (or a maximum radiation dose in the rectal wall >75 Gy) resulted in a higher incidence of severe rectal bleeding (p

  4. Effects of radiotherapy in the treatment of multiple myeloma

    International Nuclear Information System (INIS)

    Ochtrop, Thomas Alexander

    2015-01-01

    Palliative irradiation of osteolytic lesions is a considerable component in the treatment for patients with multiple myeloma. In this study, we analyzed the efficacy of irradiation in these patients. Patients and methods: We retrospectively analyzed 153 patients with multiple myeloma who were admitted to our department between 1989 and 2013. According to the staging system of Durie and Salmon 116 patients were classified as stage III. 107/153 patients were treated with radiotherapy of at least one and up to 6 bony lesions at different times. In order to evaluate the effect of local radiotherapy on pain relief and bone recalcification a uni- and multivariate analysis was performed using a binary logistic regression model to correct for multiple measurements. Complete information on dose, fractionation and volume of radiotherapy was available from 81 patients treated in 136 target volumes for pain relief, and from 69 patients treated in 108 target volumes for recalcification. Total radiation doses varied between 8 Gy to 50 Gy (median dose 25 Gy in 2.5 Gy fractions, 5 times a week). Results: Radiotherapy resulted in complete local pain relief in 31% and partial local pain relief in 54% of the patients. In the univariate analysis, higher total radiation doses (p = 0.023) and higher age (p = 0.014) at the time of radiotherapy were significantly associated with a higher likelihood of pain relief, whereas no significant association was detected for concurrent systemic treatment, type and stage of myeloma and location of bone lesions. The same variables were independent predictors for pain relief in the multivariate analysis. Recalcification was observed in 48% of irradiated bone lesions. In the uni- and multivariate analysis higher radiation doses were significantly associated (p = 0.048) with an increased likelihood of recalcification. Side effects of radiotherapy were generally mild. Conclusions: Higher total biological radiation doses were associated with better pain

  5. Delayed complications of radiotherapy treatment for nasopharyngeal carcinoma: imaging findings

    International Nuclear Information System (INIS)

    King, A.D.; Ahuja, A.T.; Yeung, D.K.; Wong, J.K.T.; Lee, Y.Y.P.; Lam, W.W.M.; Ho, S.S.M.; Yu, S.C.H.; Leung, S.-F.

    2007-01-01

    Radiotherapy is used to treat a wide variety of head and neck tumours that arise in and around the skull base. The delayed effects of radiation damages a range of structures, including the nervous system, bone, major vessels, mucus membranes, pituitary and salivary glands, as well as increasing the risk of radiation-induced neoplasms. In this review the complications resulting from radiation treatment for nasopharyngeal carcinoma (NPC), a cancer treated with a high dose of radiation to a fairly large region, are illustrated. Many patients with NPC have a long-term survival, so are at risk of developing delayed radiation effects, and hence may demonstrate a wide range of complications on imaging. Other tumours around the skull base treated with radiotherapy include meningiomas, chordomas, chondrosarcomas, pituitary adenomas, paranasal sinus and nasal cavity tumours. In these cases similar complications may be encountered on imaging, although the severity, incidence and location will vary

  6. Results of induction chemotherapy followed by three-dimensional conformal radiotherapy and concurrent weekly paclitaxel for stage III non-small cell lung cancer

    International Nuclear Information System (INIS)

    Wang Weihua; Bao Yong; Chen Ming; Zhang Li; Xu Guangchuan; Li Kaixin

    2008-01-01

    Objective: To evaluate the toxicity and efficacy of induction chemotherapy (ICT) followed by three-dimensional conformal radiotherapy (3DCRT) plus concurrent weekly paclitaxel for inoperable non-small cell lung cancer (NSCLC). Methods: Patients with stage III NSCLC in favorable conditions were treated with 2 to 4 cycles of carboplatin (AUC=5-6, d1) combined with paclitaxel (175 mg/m 2 , d1), then followed by weekly paclitaxel (40 mg/m 2 ) and concurrent 3DCRT within 34 weeks. The prescription dose of radiotherapy was given as high as possible while total lung V 20 ≤31% and total dose of the spinal cord ≤50 Gy. Results: ICT was well tolerated. During the concurrent chemoradiotherapy,the treatment of 4 patients was ended ahead of the schedule because of severe pulmonary and cardiac toxicities; the treatment of 2 patients was delayed for 7 and 12 days because of fatigue. Leucopenia(33/56) was in grade 1-2 except 1 patient in grade 3. Lymphocytopenia was severe (54/56,42 in grade 3). Three patients developed grade 3 acute radiation-induced esophagitis, and 3 developed grade 3-4 radiation-induced pneumonitis. There was one patients each who developed grade 2,3, and 4 late esophageal damage, respectively. Nine developed grade 2 pulmonary fibrosis. The overall response rate was 69.7%. The 1-year overall survival rate was 72.3%. The 1-year local progression-free survival rate was 62.7%. Conclusions: The schedule of ICT followed by weekly paclitaxel and concurrent 3DCRT can be well tolerated by most of the favorable patients with stage III NSCLC, and the toxicity is tolerable. Results of this study are encouraging, though long-term results should be followed up. (authors)

  7. Digital linear accelerator: The advantages for radiotherapy

    International Nuclear Information System (INIS)

    Andric, S.; Maksimovic, M.; Dekic, M.; Clark, T.

    1998-01-01

    Technical performances of Digital Linear Accelerator were presented to point out its advantages for clinical radiotherapy treatment. The accelerator installation is earned out at Military Medical Academy, Radiotherapy Department, by Medes and Elekta companies. The unit offers many technical advantages with possibility of introduction new conformal treatment techniques as stereotactic radiosurgery, total body and total skin irradiation. In the paper are underlined advantages in relation to running conventional accelerator units at Yugoslav radiotherapy departments, both from technical and medical point of view. (author)

  8. [Role of radiotherapy in the treatment of multiple myeloma].

    Science.gov (United States)

    Mose, S; Pfitzner, D; Rahn, A; Nierhoff, C; Schiemann, M; Böttcher, H D

    2000-11-01

    Chemotherapy is the treatment of choice in multiple myeloma; but there are no curative options. Therefore, the treatment rationale is characterized by reduction of symptoms and inhibition of complications. Regarding reduction of pain, treatment of (impending) fractures, and spinal cord compression radiation is an important part of palliative treatment. In our retrospective study we report the effect of radiotherapy on reduction of pain, recalcification and the reduction of neurological symptoms and evaluate factors which have an impact on therapeutic outcome. From 1, Jan 1988 to 31, Dec 1998, 42 patients (19 women, 23 men; range of ages 46 to 85 years, median age 64.9 years) with 71 target volumes were irradiated (median dose 36 Gy, 2 to 3 Gy 5 times/week) because of symptomatic disease (67/71: osseous pain, 45/71: fractures/impending fractures, 13/71: spinal cord compression) (Tables 1 and 2). The median time from diagnosis to the first course of radiotherapy was 11.9 months (0.3 to 90 months). At the time of first irradiation, 5 and 37 patients were in tumor Stage II and III (Salmon/Durie), respectively. The median value of the Karnofsky performance was 70% (40 to 90%). During follow-up (at least 6 months) in 85% of target volumes complete and partial pain relief (measured by patients' perception and the use of analgetic medication) was achieved; recurrences were seen in 8.8%. In 26/56 (46.4%) lesions evaluable a recalcification was seen whereas 17.9% showed progressive disease (comparison of radiographs before and after radiation). In 22.3% of all lesions initially with impending fracture (4/18) radiotherapy failed because of fracture after treatment (Tables 3 and 4). Simultaneous chemotherapy and a Karnofsky performance > or = 70 had a significant impact on a positive response to treatment, respectively. Spinal cord compression symptoms were reduced in 7/13 (53.8%) of patients (scaled due to the classification by Findlay 1987). The median survival from

  9. Automatic liver contouring for radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Li, Dengwang; Kapp, Daniel S; Xing, Lei; Liu, Li

    2015-01-01

    To develop automatic and efficient liver contouring software for planning 3D-CT and four-dimensional computed tomography (4D-CT) for application in clinical radiation therapy treatment planning systems.The algorithm comprises three steps for overcoming the challenge of similar intensities between the liver region and its surrounding tissues. First, the total variation model with the L1 norm (TV-L1), which has the characteristic of multi-scale decomposition and an edge-preserving property, is used for removing the surrounding muscles and tissues. Second, an improved level set model that contains both global and local energy functions is utilized to extract liver contour information sequentially. In the global energy function, the local correlation coefficient (LCC) is constructed based on the gray level co-occurrence matrix both of the initial liver region and the background region. The LCC can calculate the correlation of a pixel with the foreground and background regions, respectively. The LCC is combined with intensity distribution models to classify pixels during the evolutionary process of the level set based method. The obtained liver contour is used as the candidate liver region for the following step. In the third step, voxel-based texture characterization is employed for refining the liver region and obtaining the final liver contours.The proposed method was validated based on the planning CT images of a group of 25 patients undergoing radiation therapy treatment planning. These included ten lung cancer patients with normal appearing livers and ten patients with hepatocellular carcinoma or liver metastases. The method was also tested on abdominal 4D-CT images of a group of five patients with hepatocellular carcinoma or liver metastases. The false positive volume percentage, the false negative volume percentage, and the dice similarity coefficient between liver contours obtained by a developed algorithm and a current standard delineated by the expert group

  10. Optimal radiation port arrangements for hepatic tumor using 3-dimensional conformal radiotherapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ik Jae; Seong, Jin Sil; Shim, Su Jung; Jeong, Kyoung Keun [Yonsei Univ., Seoul (Korea, Republic of); Cho, Kwang Hwan [Sunchunhyang Univ., Buchon (Korea, Republic of)

    2006-12-15

    The purpose of this study was to investigate the optimal beam arrangements for hepatic tumors, according to the location of the hepatic tumor and its relationship to Organs At Risk (OARs). The virtual gross tumor volumes were divided into four groups according to the Couinaud's classification. Several plans were made for each virtual target, and these plans were compared for the Normal Tissue Complication Probabilities (NTCP). For group I, NTCP improved as the number of the beam ports increased. However, plans with more than 5 ports had little advantage. For group II, plans with the beam directions from the anterior side showed better results. Group III contained many OARs near the target, which placed restrictions on the beam-directions. Multi-directional plans yielded a higher dose to the OARs than a simple two-port plan using right anterior oblique and posterior beam (RAO/PA). For group IV, a simple RAO/PA port plan was adequate for protection of remaining liver. NTCP can significantly vary between radiotherapy plans when the location of the tumor and its neighboring OARs are taken into consideration. The results in this study of optimal beam arrangements could be a useful set of guidelines for radiotherapy of hepatic tumors.

  11. Selection of candidate wells and optimization of conformance treatment design in the Barrancas Field using a 3D conformance simulator

    Energy Technology Data Exchange (ETDEWEB)

    Crosta, Dante; Elitseche, Luis [Repsol YPF (Argentina); Gutierrez, Mauricio; Ansah, Joe; Everett, Don [Halliburton Argentina S.A., Buenos Aires (Argentina)

    2004-07-01

    Minimizing the amount of unwanted water production is an important goal at the Barrancas field. This paper describes