WorldWideScience

Sample records for computerized tomographical analysis

  1. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  2. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  3. Development of a computerized tomographic system based on the FAN-BEAM technique

    International Nuclear Information System (INIS)

    Junqueira, M.M.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory, at COPPE/UFRJ, concentrates its researches in the development of computerized tomographic systems, looking for applications in industrial and medical non destructive analysing techniques. In this work we have projected and constructed a tomographic prototype, based on the FAN-BEAM technique for irradiating the object under analysis. An algorithm previously developed to analyse parallel beams, was modified and adapted to the FAN-BEAM geometry. (Author) [pt

  4. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  5. Computerized tomographic findings in children with head trauma in ...

    African Journals Online (AJOL)

    Objective: To describe the computerized tomographic findings in children with head trauma who presented at the University of Benin Teaching Hospital, Benin City, Nigeria. Methods: It is a retrospective review of patients aged 0 – 15 years with suspected intracranial injury (ICI) following head trauma, who presented for CT ...

  6. ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Huang, S.C.; Kuhl, D.E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems

  7. Spiral Computed Tomographic Imaging Related to Computerized Ultrasonographic Images of Carotid Plaque Morphology and Histology

    DEFF Research Database (Denmark)

    Grønholdt, Marie-Louise M.; Wagner, Aase; Wiebe, Britt M.

    2001-01-01

    Echolucency of carotid atherosclerotic plaques, as evaluated by computerized B-mode ultrasonographic images, has been associated with an increased incidence of brain infarcts on cerebral computed tomographic scans. We tested the hypotheses that characterization of carotid plaques on spiral comput...

  8. Computerized tomographic scanner with shaped radiation filter

    International Nuclear Information System (INIS)

    Carlson, R.W.; Walters, R.G.

    1981-01-01

    The invention comprises a shaped filter and a filter correction circuitry for computerized tomographic scanners. The shaped filter is a generally u-shaped block of filter material which is adapted to be mounted between the source of radiation and the scan circle. The u-shaped block has a parabolic recess. The filter material may be beryllium, aluminum, sulphur, calcium, titanium, erbium, copper, and compounds including oxides and alloys thereof. The filter correction circuit comprises a first filter correction profile adding circuit for adding a first scaler valve to each intensity valve in a data line. The data line is operated on by a beam hardness correction polynomial. After the beam hardness polynomial correction operation, a second filter correction circuit adds a second filter correction profile consisting of a table of scalor values, one corresponding to each intensity reading in the data line

  9. Computerized tomographic quantification of chronic obstructive pulmonary disease as the principal determinant of frontal P vector.

    Science.gov (United States)

    Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David

    2012-04-01

    Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Motion-Computerized Tomographic Colography is a Better Method for Screening for Polyps: Arguments for the Motion

    Directory of Open Access Journals (Sweden)

    Benoit C Pineau

    2003-01-01

    Full Text Available Colorectal cancer is an important public health problem that is amenable to prevention and early treatment. Traditional screening techniques - fecal occult blood testing, flexible sigmoidoscopy, barium enema and colonoscopy - each have limitations in terms of diagnostic accuracy, cost and/or patient acceptability. Compliance with recommendations for screening has been poor, in part, because of negative perceptions about the available modalities. Virtual colonoscopy, or computerized tomographic colography, is a minimally invasive technique that safely evaluates the entire colon and does not require sedation. Thorough cleansing as well as immobilization and air insufflation of the colon is crucial to a successful examination. Sensitivity and specificity rates are reasonable, compared with conventional colonoscopy, and it has been shown that the latter technique can be averted in over two-thirds of cases, with few false-negative examinations. Most patients find virtual colonoscopy more acceptable than the conventional technique, and would prefer it if a repeat procedure were warranted. An economic analysis that found that computerized tomographic colography was less cost effective than conventional colonoscopy did not consider the indirect costs of the latter, which is an important limitation. Virtual colonoscopy is a novel radiological technique that may revolutionize screening for colorectal cancer.

  11. First experience with a mobile computed tomograph in the USSR

    International Nuclear Information System (INIS)

    Portnoj, L.M.

    1989-01-01

    Utilization experience of mobile computerized tomograph mounted in the bus is presented. Problems concerning staff, selection of medical base institutes etc are considered. Efficiency of mobile computerized tomographes in revealing different diseases is pointed out

  12. Analysis of concrete material through gamma ray computerized tomography

    International Nuclear Information System (INIS)

    Oliveira Junior, J.M. de

    2004-01-01

    Computerized Tomography (CT) refers to the cross sectional imaging of an object from both transmission or reflection data collected by illuminating the object from many different directions. The most important contribution of CT is to greatly improve abilities to distinguish regions with different gamma ray transmittance and to separate over-lying structures. The mathematical problem of the CT imaging is that of estimating an image from its projections. These projections can represent, for example, the linear attenuation coefficient of γ-rays along the path of the ray. In this work we will present some new results obtained by using tomographic techniques to analyze column samples of concrete to check the distribution of various materials and structural problems. These concrete samples were made using different proportions of stone, sand and cement. Another set of samples with different proportions of sand and cement were also used to verify the outcome from the CT analysis and the differences between them. Those samples were prepared at the Material Laboratory of Faculdade de Engenharia de Sorocaba, following the same procedures used in real case of concrete tests. The projections used in this work was obtained by Mini Computerized Tomograph of Uniso (MTCU), located at the Experimental Nuclear Physics Laboratory at University of Sorocaba. This tomograph operates with a gamma ray source of 241 Am (photons of 60 keV and 100 mCi of intensity) and a NaI(Tl) solid state detector. The system features translation and rotation scanning modes, a 100 mm effective field of view, and 1 mm spatial resolution. The image reconstruction problem is solved using Discrete Filtered Backprojection (FBP). (author)

  13. A computerized tomographic study in patients with delusional and non-delusional depression

    International Nuclear Information System (INIS)

    Shiraishi, Hiroyasu; Koizumi, Junzo; Hori, Masashi; Terashima, Yasushi; Suzuki, Toshihito; Saito, Kiichiro; Mizukami, Katsuyoshi; Tanaka, Yoshiro; Yamaguchi, Naomi

    1992-01-01

    This is a description of a computerized tomographic study of 45 non-delusional depressed, 29 delusional depressed patients and 77 neurotic control subjects. The cerebral atrophy ratio (CAR) on the three different slices and the ventricular ratio (VBR) of the anterior horn and the body of the lateral ventricles were calculated, analyzed and compared using Student's t test. Compared to the control subjects, the non-delusional depressive patients had greater CAR values than the controls but there were no significant differences of VBR values between the two groups. The patients with delusional depression had significantly larger CAR and VBR values than the non-delusional depressives and control subjects. The delusional depressives had greater brain atrophy than the non-delusionals and it was suggested that organic cerebral factors may have etiological significance in the depressions, especially the delusional depressives. (author)

  14. Automated angular and translational tomographic alignment and application to phase-contrast imaging

    DEFF Research Database (Denmark)

    Cunha Ramos, Tiago Joao; Jørgensen, Jakob Sauer; Andreasen, Jens Wenzel

    2017-01-01

    X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object po...... improvement in the reconstruction resolution. A MATLAB implementation is made publicly available and will allow robust analysis of large volumes of phase-contrast tomography data.......X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object...... reconstruction artifacts and limit the attained resolution in the final tomographic reconstruction. Alignment algorithms that require manual interaction impede data analysis with ever-increasing data acquisition rates, supplied by more brilliant sources. We present in this paper an iterative reconstruction...

  15. Computerized tomography in the diagnosis of mechanical jaundice

    International Nuclear Information System (INIS)

    Grushin, Yu.V.; Manasov, T.Zh.; Raskolenko, A.A.; Nazyrova, N.K.; Dzhumashev, E.Z.

    1987-01-01

    A total of 51 patients with suspected mechanical jaundice were examined using the 3rd generation computerized tomograph. A correct conclusion as to the level and mechanism of obstruction was made in 77% of cases. The most serious problems arose in analysis of extrahepatic biliary ducts. The dilatation of the biliary passages was not always combined with their obturation. In cases which were difficult for interpretation, additional information could be obtained by using thin tomographic layers, i.v. contrast enhancement, and retrograde endoscopic cholangiography

  16. Computerized industrial tomography

    International Nuclear Information System (INIS)

    Ashraf, M.M.

    1999-01-01

    Computerized Tomographic (CT) has been used for a number of applications in the field of medicine and industry. For the last couple of years, the technique has been applied for the material characterization and detection of defects and flaws inside the industrial components of nuclear, aerospace and missile industries. A CT scanner of first generation was developed at the institute. The scanner has been used to demonstrate couple of applications of CT in the field of non destructive testing of materials. The data acquired by placing the test objects at various angles and scanning the object through a source detector assembly has been processed on a Pentium computer for image reconstruction using a filtered back projection method. The technique has been developed which can be modified and improved to study various other applications in materials science and a modern computerized tomographic facility can be established. (author)

  17. Anatomical Variations of Carotid Artery and Optic Nerve in Sphenoid Sinus Using Computerized Tomographic Imaging

    Directory of Open Access Journals (Sweden)

    Nikakhlagh

    2014-12-01

    Full Text Available Background Sphenoid sinus is surrounded by many vital vascular and nervous structures. In more than 20% of patients with chronic sinusitis, involvement of sphenoid sinus has been observed. Besides, sphenoid sinus is an appropriate route to access anterior and middle cranial fossa in surgery. Therefore, it is important to have an adequate knowledge about the contents of sphenoid sinus and its proximity for nasal endoscopy, sinus surgeries and neurosurgeries. Objectives The aim of this study was to study sphenoid sinus proximity with carotid artery and the optic nerve using computerized tomographic imaging. Materials and Methods In this prospective study, computerized tomographic images of sphenoid sinus of patients referred to Imam Khomeini and Apadana hospitals were studied. The images were studied regarding any bulging, as well as not having a bone covering in sphenoid sinus regarding internal carotid artery and optic nerve. Furthermore, unilateralness or bilateralness of their relationships was studied. Results Among 468 coronal and axial CT scan images of sphenoid sinus, 365 (78% showed post-sellar pneumatization and 103 (22% pre-sellar pneumatization. Regarding existence of internal septa, 346 (74% cases showed multiple septation, and the remaining images were reported to have a single septum. According to the reports of CT scan images, the existence of bulging as a result of internal carotid artery and uncovered artery were 4.22% and 5.8% in the right sinus, 4.9% and 5.4% in the left sinus, and 4.34% and 4.6% in both sinuses, respectively. According to the reports of CT scan images, existence of bulging as a result of optic nerve and uncovered nerve were 5.7% and 4.3% in the right sinus, 6% and 5.4% in the left sinus, and 12% and 3.2% in both sinuses, respectively. Conclusions Due to variability of sphenoid sinus pneumatization and the separator blade of the two sinus cavities, careful attention is required during sinus surgery to avoid

  18. Computer tomographic detection of an intraspinal arachnoidal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kuckein, D; Walter, K; Paal, G

    1981-03-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location.

  19. Computer tomographic detection of an intraspinal arachnoidal cyst

    International Nuclear Information System (INIS)

    Kuckein, D.; Walter, K.; Paal, G.; Staedtisches Krankenhaus Harlaching, Muenchen

    1981-01-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location. (MG) [de

  20. Multidetector computerized tomographic fistulography in the evaluation of congenital branchial cleft fistulae and sinuses.

    Science.gov (United States)

    Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen

    2012-05-01

    The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Computer tomographic examinations in epilepsy

    International Nuclear Information System (INIS)

    De Villiers, J.F.K.

    1984-01-01

    Epileptic patients that was examined at the Universitas Hospital (Bloemfontein) by means of computerized tomography for the period July 1978 - December 1980, are divided into two groups: a) Patients with general epilepsy of convulsions - 507; b) Patients with vocal or partial epilepsy - 111. The method of examination and the results for both general and vocal epilepsy are discussed. A degenerative state was found in 35% of the positive computer tomographic examinations in general epilepsy and 22% of the positive examinations for vocal epilepsy. The purpose of the article was to explain the circumstances that can be expected when a epileptic patient is examined by means of computerized tomography

  2. Precision tomographic analysis of reactor fuels

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research.

  3. Precision tomographic analysis of reactor fuels

    International Nuclear Information System (INIS)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research

  4. Development of a computerized tomographic system

    International Nuclear Information System (INIS)

    Borges, J.C.; Santos, C.A.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory at COPPE/UFRJ has been developing techniques for detection and applications of nuclear radiations. A lot of research work has been done and resulted in several M.Sc. and D.Sc. thesis, concerning subjects like neutrongraphy, gammagraphy, image reconstruction, special detectors, etc. Recent progress and multiple applications of the computerized tomography to medical and industrial non-destructive tests, pushed the Laboratory to a vast program in this field of research. In this paper, we report what has been done and the results obtained. (Author) [pt

  5. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  6. Computerized three-dimensional normal atlas

    International Nuclear Information System (INIS)

    Mano, Isamu; Suto, Yasuzo; Suzuki, Masataka; Iio, Masahiro.

    1990-01-01

    This paper presents our ongoing project in which normal human anatomy and its quantitative data are systematically arranged in a computer. The final product, the Computerized Three-Dimensional Normal Atlas, will be able to supply tomographic images in any direction, 3-D images, and coded information on organs, e.g., anatomical names, CT numbers, and T 1 and T 2 values. (author)

  7. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  8. Geometrical efficiency in computerized tomography: generalized model

    International Nuclear Information System (INIS)

    Costa, P.R.; Robilotta, C.C.

    1992-01-01

    A simplified model for producing sensitivity and exposure profiles in computerized tomographic system was recently developed allowing the forecast of profiles behaviour in the rotation center of the system. The generalization of this model for some point of the image plane was described, and the geometrical efficiency could be evaluated. (C.G.C.)

  9. Computerized tomographic evaluation of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Young; Lee, Mi Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Precbyterian Medical Center, Chonju (Korea, Republic of)

    1988-08-15

    Cerebral cysticercosis, unfortunately frequent in Korea, is a parastic disease in which man serve as the intermediate host of taenia solium. The larvae have a predilection for the central nervous system and can cause a variety of neurologic symptoms. The authors reviewed 19 cases of surgically proven cerebral cysticercosis and following results were obtained. 1. The most frequent age distribution was 5th and 6th decade and male to female ratio was 14:5. 2. The most frevalent involving site was cerebral parenchyme and following by ventricles. 3. Clinical manifestations were symtom and sign of increased ICP, seizure and focal neurological dificit. 4. It was assumed that computerized tomography was the procedure of choice for the diagnosis of these parasitic brain disease.

  10. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  11. Computerized tomography

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the design of computerized tomographic X-ray equipment are described which lead to improvements in the mechanical properties, speed and size of scanning areas. The method envisages the body being scanned as a two-dimensional matrix of elements arising from a plurality of concentric rings. The concentric centre need not coincide with the axis of rotation. The procedures for rotation of the X-ray beam and detectors around the patient and for translating the measured information into attenuation coefficients for each matrix element of the body are described in detail. Explicit derivations are given for the mathematical formulae used. (U.K.)

  12. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  13. Human Reliability Analysis For Computerized Procedures

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Gertman, David I.; Le Blanc, Katya

    2011-01-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  14. Computerized spleen volumetry

    International Nuclear Information System (INIS)

    Jahnke, T.; Mohring, R.; Schertel, L.

    1981-01-01

    We examined in experimental studies and clinical investigations on 34 patients in how far volumetry of the spleen can be carried out with a commonly available program, a whole-body computerized tomograph (SOMATOM) and an analytic equipment (EVALUSKOP). In this connection the authors tried to find also other ways of spleen volumetry by means of this unit combination. Our final result was that the given program for the usage of labelled areas presents itself as the best-suited technique for spleen volumetry which is also applicable in practice. (orig./MG) [de

  15. Tomographic apparatus for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus which can be used in computerized tomographic systems for producing a fan shaped beam, detectors to be used in conjunction with the source and equipment for rotating the source supports are described. (U.K.)

  16. Ultrasonic and computerized tomographic semiotics of cholelithiasis

    International Nuclear Information System (INIS)

    Kishkovskij, A.N.; Kuznetsov, S.V.; Fadeev, V.D.

    1986-01-01

    Altogether 447 patients with suspected cholelithiasis were examined by means of routine X-ray methods, ultrasound (US) and computerized tomography (CT).Of them in 104 (23.3%) chole- and/or choledocholithiasis were later confirmed. An US and CT-picture of the biliferous tracts in health were described.In cholelithiasis during US examination echogenic concrements producing a stable acoustic shadow were defined in the gall bladder cavity and/or in the biliferous ducts. A study was made of the features of the US picture with relation to size, quantity, echodensity and grouping of concrements in the biliferous ducts. CT-symptomatology of cholelithiasis was described

  17. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  18. Computerized tomographic findings of hepatic fascioliasis compared with melioidosis-caused liver abscesses.

    Science.gov (United States)

    Chamadol, Nittaya; Laopaiboon, Vallop; Techasatian, Pennapa; Sukeepaisanjaroen, Wattana; Sripanuskul, Anan

    2010-07-01

    To compare the computerized tomographic (CT) findings of hepatic fascioliasis (HF) vs. melioidosis-caused liver (ML) abscesses. CT images of 15 patients with hepatic fascioliasis (HF) and 16 patients with melioidosis-caused liver (ML) abscesses were retrospectively reviewed. The authors evaluated and compared HF and ML abscesses (by chi2 and Fisher exact tests) vis-a-vis their location of liver involvement, size, shape, number margins, enhancement patterns, subcapsular lesions, internal architecture, dilatation of intrahepatic bile duct and combination with splenic abscesses. Fourteen HF patients had only liver abscesses and 1 had combined liver and splenic abscesses. Four ML patients had liver abscesses alone while 12 had combined liver and splenic abscesses (p = 0.000). Eight of the 15 HF (53.3%) and 2 of the 16 ML (12.5%) patients had subcapsular lesions (p = 0.019). The liver abscesses were round or oval with linear tracts in 8 of the 15 HF (53.3%) and none of the ML patients (p = 0.001). Between the respective HF and ML patients, there was a significant difference in those with round shaped in ML (p = 0.008), multiple and conglomerately distributed in HF (p = 0.050), multiple and discretely distributed in ML (p = 0.001) no (or minimal) peripheral contrast enhancement in HF (p = 0.011) and moderate or mark peripheral enhancement in ML (p = 0.011). The CT findings of liver abscesses that helped to differentiate hepatic fascioliasis from melioidosis liver abscesses were: their number shape, enhancement pattern, presence of subcapsular lesion (s) and co-occurrence with splenic abscesses. The diagnosis of hepatic fascioliasis by CT is suggested when the following characteristics were seen: (1) multiple, small round or oval (with linear tracts) conglomerates presenting as hypodense lesions; (2) no (or minimal) peripheral contrast enhancement; (3) subcapsular lesions; or (4) less frequent co-occurrence with splenic abscesses.

  19. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  20. Tomographic apparatus and method for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    An apparatus is described which can be used in computerized tomographic systems for constructing a representation of an object and which uses a fan-shaped beam source, detectors and a convolution method of data reconstruction. (U.K.)

  1. Positioning of Nuclear Fuel Assemblies by Means of Image Analysis on Tomographic Data

    International Nuclear Information System (INIS)

    Troeng, Mats

    2005-06-01

    A tomographic measurement technique for nuclear fuel assemblies has been developed at the Department of Radiation Sciences at Uppsala University. The technique requires highly accurate information about the position of the measured nuclear fuel assembly relative to the measurement equipment. In experimental campaigns performed earlier, separate positioning measurements have therefore been performed in connection to the tomographic measurements. In this work, another positioning approach has been investigated, which requires only the collection of tomographic data. Here, a simplified tomographic reconstruction is performed, whereby an image is obtained. By performing image analysis on this image, the lateral and angular position of the fuel assembly can be determined. The position information can then be used to perform a more accurate tomographic reconstruction involving detailed physical modeling. Two image analysis techniques have been developed in this work. The stability of the two techniques with respect to some central parameters has been studied. The agreement between these image analysis techniques and the previously used positioning technique was found to meet the desired requirements. Furthermore, it has been shown that the image analysis techniques offer more detailed information than the previous technique. In addition, its off-line analysis properties reduce the need for valuable measurement time. When utilizing the positions obtained from the image analysis techniques in tomographic reconstructions of the rod-by-rod power distribution, the repeatability of the reconstructed values was improved. Furthermore, the reconstructions resulted in better agreement to theoretical data

  2. Evaluation of quality of tomographs of Rio de Janeiro state, Brazil

    International Nuclear Information System (INIS)

    Travassos, P.C.B.; Belem, V.R.; Magalhaes, L.A.; Almeida, C.E.A. de

    2014-01-01

    Computerized tomographs used in 56 institutions in the state of Rio de Janeiro were evaluated. Criteria of image quality and dosimetry were submitted. The results showed that some not performed optimize their protocols examinations or perform wrongly, which results in an increase in the dose received by patients, and an image in compromised quality. (author)

  3. Computerized ECT data analysis system

    International Nuclear Information System (INIS)

    Miyake, Y.; Fukui, S.; Iwahashi, Y.; Matsumoto, M.; Koyama, K.

    1988-01-01

    For the analytical method of the eddy current testing (ECT) of steam generator tubes in nuclear power plants, the authors have developed the computerized ECT data analysis system using a large-scale computer with a high-resolution color graphic display. This system can store acquired ECT data up to 15 steam generators, and ECT data can be analyzed immediately on the monitor in dialogue communication with a computer. Analyzed results of ECT data are stored and registered in the data base. This system enables an analyst to perform sorting and collecting of data under various conditions and obtain the results automatically, and also to make a plan of tube repair works. This system has completed the test run, and has been used for data analysis at the annual inspection of domestic plants. This paper describes an outline, features and examples of the computerized eddy current data analysis system for steam generator tubes in PWR nuclear power plants

  4. Computerization of the safeguards analysis decision process

    International Nuclear Information System (INIS)

    Ehinger, M.H.

    1990-01-01

    This paper reports that safeguards regulations are evolving to meet new demands for timeliness and sensitivity in detecting the loss or unauthorized use of sensitive nuclear materials. The opportunities to meet new rules, particularly in bulk processing plants, involve developing techniques which use modern, computerized process control and information systems. Using these computerized systems in the safeguards analysis involves all the challenges of the man-machine interface experienced in the typical process control application and adds new dimensions to accuracy requirements, data analysis, and alarm resolution in the regulatory environment

  5. Comparative validation of the radiographic and tomographic measurement of patellar height

    Directory of Open Access Journals (Sweden)

    Marco Antonio Schueda

    2013-09-01

    Full Text Available OBJECTIVE: To evaluate and validate the radiographic measurement of patellar height with computerized tomography scans. METHODS: Measured the patellar height through the lateral radiographic image supported by one foot and sagittal tomographic view of the knee in extension, flexion of 20°, and quadriceps contraction of 40 patients (80 knees, asymptomatic and no history of knee injuries using Insall-Salvati index. There were 20 adult females and 20 adult males. RESULTS: The height patellar index was higher in women of all images taken, in proportion. There was no statistical difference of patellar height index between the radiographics and tomographics images. CONCLUSION: The Insall-Salvati index in females was higher in all cases evaluated. Furthermore, it is possible to measure the patellar height index during tomographic study without distorting the results obtained, using to define the presence of patella alta or patella baja.

  6. Interictal "patchy" regional cerebral blood flow patterns in migraine patients. A single photon emission computerized tomographic study

    DEFF Research Database (Denmark)

    Friberg, L; Olesen, J; Iversen, Helle Klingenberg

    1994-01-01

    In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right-left asymme......In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right...... rCBF images is insufficient to pick up abnormalities; (2) almost 50% of the migraine sufferers had abnormal rCBF/asymmetries. However, these are discrete compared with those typically seen during the aura phase of a migraine attack. One explanation to the patchy rCBF patterns might...

  7. Computerized tomography of adrenal glands in the investigation of Cushing's syn

    International Nuclear Information System (INIS)

    Abucham Filho, J.; Albertotti, C.; Kater, C.E.; Vieira, J.G.H.; Chacra, A.R.

    1983-01-01

    Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author) [pt

  8. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  9. Investigating the correlation between computerized tomography changes and quantitative consciousness disturbances in stroke patients

    International Nuclear Information System (INIS)

    Toneva, Yu.; Manchev, I.; Tsolova, M.

    1997-01-01

    One-hundred and nine patients undergo computerized tomographic (CT) and clinical investigations. The correlation between CT finding and quantitative consciousness disturbances has been studied. The somatic, neurologic and mental states are evaluated, and the changes in consciousness are classified according to a 4-degree rating system adopted in this country, namely: obnubilation, somnolence, sopor and coma. For the purpose a computerized tomograph CE 10000 is used. Cerebral infarctions in the right middle cerebral artery pool predominate. Here the disturbances are of a milder degree - obnubilation and somnolence. In stroke syndrome cases the states of sopor and coma are more frequent which may be explained with the rather severely manifested brain edema. In either form of cerebrovascular disease the quantitative disorders of consciousness are not dependent on the location of the accident in the dominant hemisphere. They are directly related to the CT documented size of pathological focus

  10. Computerized tomographic studies in cerebral palsy

    International Nuclear Information System (INIS)

    Sugie, Yoko

    1981-01-01

    Computed tomographic (CT) findings in 200 children with cerebral palsy (CP) were analysed from the viewpoint of clinical manifestations, disease complications and etiological factors. CT scans of 135 cases (67.5%) were found to be abnormal and there were 14 (7%) borderline cases. The major abnormality found on CT scans was cerebral atrophy. Other important changes included focal or diffuse low density area in the brain tissue, congenital malformation, and cerebellar atrophy. From the clinical point of view, a large number of patients with spastic tetraplegia and spastic diplegia showed highly abnormal CT scans. On the other hand, in patients with spastic monoplegia, spastic paraplegia, and athetotic type, CT findings were normal or revealed only minor cerebral atrophy. Most children showing asymmetric clinical symptoms had corresponding asymmetric CT abnormalities which included ventricular enlargement, low density area in the brain tissue, and hemispherical volume. There was a significant correlation between the severity of physical impairment and the extent of CT abnormalities. Severely affected children had grossly abnormal CT scans such as hydranencephaly, polycystic change, and extensive cerebral atrophy. In the patients complicated with epilepsy, the incidence and severity of abnormal CT were higher than those of non-epileptic patients. Mentally retarded patients had variable enlargement of the subarachnoidal space depending on the severity of their mental retardation. Patients with suspected postnatal etiology also had high incidence of severe CT abnormality. CT scan is a valuable tool for evaluating patients with CP and in some cases, possible etiology of the disease may be discovered. (author)

  11. Coupling two iteratives algorithms for density measurements by computerized tomography

    International Nuclear Information System (INIS)

    Silva, L.E.M.C.; Santos, C.A.C.; Borges, J.C.; Frenkel, A.D.B.; Rocha, G.M.

    1986-01-01

    This work develops a study for coupling two iteratives algotithms for density measurements by computerized tomography. Tomographies have been obtained with an automatized prototype, controled by a microcomputer, projected and assembled in the Nuclear Instrumentation Laboratory, at COPPE/UFRJ. Results show a good performance of the tomographic system, and demonstrate the validity of the method of calculus adopted. (Author) [pt

  12. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    Science.gov (United States)

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  13. Computerized analysis of brain perfusion parameter images

    International Nuclear Information System (INIS)

    Turowski, B.; Haenggi, D.; Wittsack, H.J.; Beck, A.; Aurich, V.

    2007-01-01

    Purpose: The development of a computerized method which allows a direct quantitative comparison of perfusion parameters. The display should allow a clear direct comparison of brain perfusion parameters in different vascular territories and over the course of time. The analysis is intended to be the basis for further evaluation of cerebral vasospasm after subarachnoid hemorrhage (SAH). The method should permit early diagnosis of cerebral vasospasm. Materials and Methods: The Angiotux 2D-ECCET software was developed with a close cooperation between computer scientists and clinicians. Starting from parameter images of brain perfusion, the cortex was marked, segmented and assigned to definite vascular territories. The underlying values were averages for each segment and were displayed in a graph. If a follow-up was available, the mean values of the perfusion parameters were displayed in relation to time. The method was developed under consideration of CT perfusion values but is applicable for other methods of perfusion imaging. Results: Computerized analysis of brain perfusion parameter images allows an immediate comparison of these parameters and follow-up of mean values in a clear and concise manner. Values are related to definite vascular territories. The tabular output facilitates further statistic evaluations. The computerized analysis is precisely reproducible, i. e., repetitions result in exactly the same output. (orig.)

  14. The use of transport and diffusion equations in the three-dimensional reconstruction of computerized tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Sandrerley Ramos, E-mail: sandrerley@eee.ufg.br [Escola de Engenharia Eletrica e de Computacao - EEEC, Universidade Federal de Goias - UFG, Goiania, GO (Brazil); Flores, Edna Lucia; Pires, Dulcineia Goncalves F.; Carrijo, Gilberto Arantes; Veiga, Antonio Claudio Paschoarelli [Faculdade de Engenharia Eletrica - FEELT, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil); Barcelos, Celia Aparecida Z. [Faculdade de Matematica, Universidade Federal de Uberlandia - UFU, Uberlandia, MG (Brazil)

    2012-09-15

    The visualization of a computerized tomographic (TC) exam in 3D increases the quality of the medical diagnosis and, consequently, the success probability in the treatment. To obtain a high quality image it is necessary to obtain slices which are close to one another. Motivated towards the goal of reaching an improved balance between quantity of slices and visualization quality, this research work presents a digital inpainting technique of 3D interpolation for CT slices used in the visualization of human body structures. The inpainting is carried out via non-linear partial differential equations (PDE). The PDE's have been used, in the image-processing context to fill in the damaged regions in a digital 2D image. Inspired by this idea, this article proposes an interpolation method for the filling in of the empty regions between the CT slices. To do it, considering the high similarity between two consecutive real slice, the first step of the proposed method is to create the virtual slices. The virtual slices contain all similarity between the intercalated slices and, when there are not similarities between real slices, the virtual slices will contain indefinite portions. In the second step of the proposed method, the created virtual slices will be used together with the real slices images, in the reconstruction of the structure in three dimensions, mapped onto the exam. The proposed method is capable of reconstructing the curvatures of the patient's internal structures without using slices that are close to one another. The experiments carried out show the proposed method's efficiency. (author)

  15. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    Science.gov (United States)

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant

  16. Computerized tomography in diagnosis of cerebrocranial injury

    International Nuclear Information System (INIS)

    Kornienko, V.N.; Vasin, N.Ya.; Kuz'menko, V.A.

    1987-01-01

    The method of computerized tomographical examination are presented. Th KT-characters of concussion of the brain, its contusion of different severity, compressions in case of traumatic intracranial hematomas, contusion injuries, brain edema and different aftereffects of cerebrocranial injury are given. On the basis of comparison of the data of clinical and KT examination the dynamics of intracranial traumatic injuries in the course of treatment is described. The problems of therapeutic and surgical tactics depending on the degree and form of intracranial structure injuries and the phase of clinical course of posttraumatic process are discussed

  17. Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

    International Nuclear Information System (INIS)

    Frayer, Daniel K.; Johnson, Douglas; Ekdahl, Carl

    2010-01-01

    An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

  18. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  19. Current Human Reliability Analysis Methods Applied to Computerized Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring

    2012-06-01

    Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room (Fink et al., 2009). Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of enhanced ease of use and easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

  20. Cardiac imaging systems and methods employing computerized tomographic scanning

    International Nuclear Information System (INIS)

    Richey, J.B.; Wake, R.H.; Walters, R.G.; Hunt, W.F.; Cool, S.L.

    1980-01-01

    The invention relates to cardiac imaging systems and methods employing computerised tomographic scanning. Apparatus is described which allows an image of the radiation attenuation of the heart at a desired phase of the cardiac cycle. The patients ECG signal can be used in a transverse-and-rotate type CT scanner as a time base, so that the beam reaches the heart at a desired phase of the cardiac cycle, or, in a purely rotational-type CT scanner continuously generated scan data is only stored for corresponding phases of successive cardiac cycles. Alternatively, gating of the beams themselves by shuttering or switching the power supply can be controlled by the ECG signal. A pacemaker is used to stabilize the cardiac period. Also used is a system for recognising unacceptable variations in the cardiac period and discarding corresponding scan data. In a transverse-and-rotate type fan-beam CT scanner, the effective beam width is narrowed to reduce the duration of the traverse of the heart. (U.K.)

  1. Positron transaxial emission tomograph with computerized image reconstruction

    International Nuclear Information System (INIS)

    Jatteau, Michel.

    1981-01-01

    This invention concerns a positron transaxial emission tomography apparatus with computerized image reconstruction, like those used in nuclear medicine for studying the metabolism of organs, in physiological examinations and as a diagnosis aid. The operation is based on the principle of the detection of photons emitted when the positrons are annihilated by impact with an electron. The appliance is mainly composed of: (a) - a set of gamma ray detectors distributed on a polygonal arrangement around the body area to be examined, (b) - circuits for amplifying the signals delivered by the gamma ray detectors, (c) - computers essentially comprising energy integration and discrimination circuits and provided at the output of the detectors for calculating and delivering, as from the amplified signals, information on the position and energy relative to each occurrence constituted by the detections of photons, (d) - time coincidence circuits for selecting by emission of detector validation signals, only those occurrences, among the ensemble of those detected, which effectively result from the annihilation of positrons inside the area examined, (e) - a data processing system [fr

  2. TomoPy: a framework for the analysis of synchrotron tomographic data

    International Nuclear Information System (INIS)

    Gürsoy, Doǧa; De Carlo, Francesco; Xiao, Xianghui; Jacobsen, Chris

    2014-01-01

    A collaborative framework for the analysis of synchrotron tomographic data which has the potential to unify the effort of different facilities and beamlines performing similar tasks is described. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports functional programming that many researchers prefer. Analysis of tomographic datasets at synchrotron light sources (including X-ray transmission tomography, X-ray fluorescence microscopy and X-ray diffraction tomography) is becoming progressively more challenging due to the increasing data acquisition rates that new technologies in X-ray sources and detectors enable. The next generation of synchrotron facilities that are currently under design or construction throughout the world will provide diffraction-limited X-ray sources and are expected to boost the current data rates by several orders of magnitude, stressing the need for the development and integration of efficient analysis tools. Here an attempt to provide a collaborative framework for the analysis of synchrotron tomographic data that has the potential to unify the effort of different facilities and beamlines performing similar tasks is described in detail. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports procedural programming that many researchers prefer. This collaborative platform could affect all major synchrotron facilities where new effort is now dedicated to developing new tools that can be deployed at the facility for real-time processing, as well as distributed to users for off-site data processing

  3. TomoPy: a framework for the analysis of synchrotron tomographic data

    Energy Technology Data Exchange (ETDEWEB)

    Gürsoy, Doǧa, E-mail: dgursoy@aps.anl.gov; De Carlo, Francesco; Xiao, Xianghui; Jacobsen, Chris [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439-4837 (United States)

    2014-08-01

    A collaborative framework for the analysis of synchrotron tomographic data which has the potential to unify the effort of different facilities and beamlines performing similar tasks is described. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports functional programming that many researchers prefer. Analysis of tomographic datasets at synchrotron light sources (including X-ray transmission tomography, X-ray fluorescence microscopy and X-ray diffraction tomography) is becoming progressively more challenging due to the increasing data acquisition rates that new technologies in X-ray sources and detectors enable. The next generation of synchrotron facilities that are currently under design or construction throughout the world will provide diffraction-limited X-ray sources and are expected to boost the current data rates by several orders of magnitude, stressing the need for the development and integration of efficient analysis tools. Here an attempt to provide a collaborative framework for the analysis of synchrotron tomographic data that has the potential to unify the effort of different facilities and beamlines performing similar tasks is described in detail. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports procedural programming that many researchers prefer. This collaborative platform could affect all major synchrotron facilities where new effort is now dedicated to developing new tools that can be deployed at the facility for real-time processing, as well as distributed to users for off-site data processing.

  4. Regional aspects of cerebral cysticercosis. Incidence and evaluation by computerized tomography in 1000 consecutive studies

    Energy Technology Data Exchange (ETDEWEB)

    Jozzolino, D.A. (Instituto de Tomografia Axial Computadorizada de Londrina (Brazil))

    One thousand consecutive studies of the entire brain were performed and 122 patients with tomographic diagnosis of cysticercosis were found. The high incidence of this disease is discussed and its endemic characteristics as well. Various forms and types are described, the most frequent being the presence of calcifications; other tests performed at the time of computerized tomography are mentioned.

  5. Computerized tomographic evaluation of primary brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Ok; Lee, Jong Soon; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Presbyterian Mediacal center, Cheonju (Korea, Republic of); Kim, Jong Deok [Inje Medical College, Paik Hospital, Pusan (Korea, Republic of)

    1985-10-15

    In a study of primary brain tumors 104 cases having satisfactory clinical, operative and histological proofs were analyzed by computerized tomography at Presbyterian Medical Center from May, 1982 to April 1985. The results were as follows: 1. The male to female ratio of primary brain tumor was 54 : 46. 2. The 2nd decade group (26%) was the most prevalent age group, followed by the 5th decade (16.3%), 1st decade (14.4%) , 3rd decade (12.5%), 4th decade (11.5%), 6th decade (10.6%), 7th decade (8.7%) in that order. 3. The incidence of primary brain tumors was found to be: glioma 64 cases (61.6%) among the GM, the most frequent 17 cases (16.3%), followed by meningioma 12 cases (11.5%), pituitary adenoma 10 cases (9.6%), craniopharyngioma 6 cases (5.8%), pinealoma and germinoma 3 cases (2.9%) respectively, and dermoid cyst 2 cases (1.9%) in that order. 4. The location of the primary brain tumors were as follows: cb. hemisphere (49%) of these 24.5% in parietal region, 11.9% in temporal region, 9.7% in frontal region, 3.0% in occipital region: juxtasella area (16.3%), cerebellar hemisphere (8.7%), parapineal and intraventricle (7.7%) respectively, cerebello-pontine angle area (5.8%), vermis and 4th ventricular region (4.8%). 5. There were no remarkable differences in the findings of pre- and post-contrast CT scanning of primary brain tumors computed with others.

  6. Morphological analysis of the vestibular aqueduct by computerized tomography images

    International Nuclear Information System (INIS)

    Marques, Sergio Ricardo; Smith, Ricardo Luiz; Isotani, Sadao; Alonso, Luis Garcia; Anadao, Carlos Augusto; Prates, Jose Carlos; Lederman, Henrique Manoel

    2007-01-01

    Objective: In the last two decades, advances in the computerized tomography (CT) field revise the internal and medium ear evaluation. Therefore, the aim of this study is to analyze the morphology and morphometric aspects of the vestibular aqueduct on the basis of computerized tomography images (CTI). Material and method: Computerized tomography images of vestibular aqueducts were acquired from patients (n = 110) with an age range of 1-92 years. Thereafter, from the vestibular aqueducts images a morphometric analysis was performed. Through a computerized image processing system, the vestibular aqueduct measurements comprised of its area, external opening, length and the distance from the vestibular aqueduct to the internal acoustic meatus. Results: The morphology of the vestibular aqueduct may be funnel-shaped, filiform or tubular and the respective proportions were found to be at 44%, 33% and 22% in children and 21.7%, 53.3% and 25% in adults. The morphometric data showed to be of 4.86 mm 2 of area, 2.24 mm of the external opening, 4.73 mm of length and 11.88 mm of the distance from the vestibular aqueduct to the internal acoustic meatus, in children, and in adults it was of 4.93 mm 2 , 2.09 mm, 4.44 mm, and 11.35 mm, respectively. Conclusions: Computerized tomography showed that the vestibular aqueduct presents high morphological variability. The morphometric analysis showed that the differences found between groups of children and adults or between groups of both genders were not statistically significant

  7. Computerized tomography of the mandibular joints and masticatory muscles

    International Nuclear Information System (INIS)

    Huels, A.B.

    1981-01-01

    A methodology for computerized tomography of the mandibular joints was developed and applied in 80 test persons. Imaging of the mandibular joints is possible with a tomographic technique with 5 mm-overlap, full utilisation of the enlargement capacity of the imaging device, and combined use of transversal and coronary tomography. The method yields full latero-medial, cranio-caudal and anterior-posterior views of the condyle and fossa contours, free of interferences and of distortions caused by the projection. Positional diagnoses are thus possible as well as diagnoses of pathological structural changes. (orig./MG) [de

  8. CONSIDERATIONS FOR THE TREATMENT OF COMPUTERIZED PROCEDURES IN HUMAN RELIABILITY ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; David I. Gertman

    2012-07-01

    Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

  9. Sensitivity study of poisson corruption in tomographic measurements for air-water flows

    International Nuclear Information System (INIS)

    Munshi, P.; Vaidya, M.S.

    1993-01-01

    An application of computerized tomography (CT) for measuring void fraction profiles in two-phase air-water flows was reported earlier. Those attempts involved some special radial methods for tomographic reconstruction and the popular convolution backprojection (CBP) method. The CBP method is capable of reconstructing void profiles for nonsymmetric flows also. In this paper, we investigate the effect of corrupted CT data for gamma-ray sources and aCBP algorithm. The corruption in such a case is due to the statistical (Poisson) nature of the source

  10. Tomographic phase analysis to detect the site of accessory conduction pathway in Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Nakajima, K.; Bunko, H.; Tada, A.; Tonami, N.; Taki, J.; Nanbu, I.; Hisada, K.; Misaki, T.; Iwa, T.

    1984-01-01

    Phase analysis has been applied to Wolff-Parkinson-White syndrome (WPW) to detect the site of accessory conduction pathway (ACP); however, there was a limitation to estimate the precise location of ACP by planar phase analysis. In this study, the authors applied phase analysis to gated blood pool tomography. Twelve patients with WPW who underwent epicardial mapping and surgical division of ACP were studied by both of gated emission computed tomography (GECT) and routine gated blood pool study (GBPS). The GBPS was performed with Tc-99m red blood cells in multiple projections; modified left anterior oblique, right anterior oblique and/or left lateral views. In GECT, short axial, horizontal and vertical long axial blood pool images were reconstructed. Phase analysis was performed using fundamental frequency of the Fourier transform in both GECT and GBPS images, and abnormal initial contractions on both the planar and tomographic phase analysis were compared with the location of surgically confirmed ACPs. In planar phase analysis, abnormal initial phase was identified in 7 out of 12 (58%) patients, while in tomographic phase analysis, the localization of ACP was predicted in 11 out of 12 (92%) patients. Tomographic phase analysis is superior to planar phase images in 8 out of 12 patients to estimate the location of ACP. Phase analysis by GECT can avoid overlap of blood pool in cardiac chambers and has advantage to identify the propagation of phase three-dimensionally. Tomographic phase analysis is a good adjunctive method for patients with WPW to estimate the site of ACP

  11. Tomographic phase analysis to detect the site of accessory conduction pathway in Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, K.; Bunko, H.; Tada, A.; Tonami, N.; Taki, J.; Nanbu, I.; Hisada, K.; Misaki, T.; Iwa, T.

    1984-01-01

    Phase analysis has been applied to Wolff-Parkinson-White syndrome (WPW) to detect the site of accessory conduction pathway (ACP); however, there was a limitation to estimate the precise location of ACP by planar phase analysis. In this study, the authors applied phase analysis to gated blood pool tomography. Twelve patients with WPW who underwent epicardial mapping and surgical division of ACP were studied by both of gated emission computed tomography (GECT) and routine gated blood pool study (GBPS). The GBPS was performed with Tc-99m red blood cells in multiple projections; modified left anterior oblique, right anterior oblique and/or left lateral views. In GECT, short axial, horizontal and vertical long axial blood pool images were reconstructed. Phase analysis was performed using fundamental frequency of the Fourier transform in both GECT and GBPS images, and abnormal initial contractions on both the planar and tomographic phase analysis were compared with the location of surgically confirmed ACPs. In planar phase analysis, abnormal initial phase was identified in 7 out of 12 (58%) patients, while in tomographic phase analysis, the localization of ACP was predicted in 11 out of 12 (92%) patients. Tomographic phase analysis is superior to planar phase images in 8 out of 12 patients to estimate the location of ACP. Phase analysis by GECT can avoid overlap of blood pool in cardiac chambers and has advantage to identify the propagation of phase three-dimensionally. Tomographic phase analysis is a good adjunctive method for patients with WPW to estimate the site of ACP.

  12. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  13. HUMAN RELIABILITY ANALYSIS FOR COMPUTERIZED PROCEDURES, PART TWO: APPLICABILITY OF CURRENT METHODS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; David I. Gertman

    2012-10-01

    Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no U.S. nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

  14. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2005-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  15. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2004-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  16. The influence of the periodontal biotype on peri-implant tissues around immediate implants with and without xenografts. Clinical and micro-computerized tomographic study in small Beagle dogs.

    Science.gov (United States)

    Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; de Souza, Sérgio L S; Palioto, Daniela B; Novaes, Arthur B

    2015-01-01

    Soft tissues and buccal bone plate remodeling after immediate implantation in sockets with thin buccal bone, using the flapless approach with or without bone graft into the buccal gap, was compared between sites with thin and normal gingiva. Eight dogs had the gingiva of one side of the mandible thinned, the mandibular premolars were extracted without flaps, and 4 implants were installed in each side, positioned 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar thickness (AT), gingival recession (GR), and probing depth (PD) were clinically evaluated. Within 12 weeks the dogs were sacrificed and the samples were analyzed by micro-computerized tomography. A thin BBT was observed in all the dogs. The presurgical procedures reduced TKT in the test group, with minimal changes of the AT. There were no statistically significant differences among the groups for the clinical parameters and the tomographic analysis showed similar linear and tri-dimensional bone reduction in all the groups. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The decrease in gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Tay-Sachs disease with conspicuous cranial computerized tomographic appearances

    International Nuclear Information System (INIS)

    Watanabe, Kishichiro; Mukawa, Akio; Muto, Kazuhiko; Nishikawa, Jiro; Takahashi, Shigeko.

    1985-01-01

    An autopsy case of a 3-year-old female infant with Tay-Sachs disease was presented. A cherry red spot in the fundus and a deficiency of N-acetyl-β-hexosaminidase A in the white blood cells were revealed soon after admission at the age of one year. Her parents and sister were found to be healthy carriers. The patient showed a typical clinical course with marked cranial swelling. In addition to the marked ballooning of neurons on light microscope, membranous cytoplasmic body (MCB) on electron microscope and abnormal accumulation of GM 2 ganglioside in the cerebral cortex by thin layer chromatography were confirmed in the autopsy specimens. In the late stage of her clinical course, the cranial computerized tomography (CT) demonstrated symmetric and deep-wavy hyperdense cerebral cortical zones, diffuse hypodensity and diminished volume of cerebral white matter, mild to moderate ventricular dilatation, and a small cerebellum and brainstem. These conspicuous appearances of the cranial CT seem to be characteristic of Tay-Sachs disease in the late stage, and they are derived from abnormal accumulation of GM 2 ganglioside in the cerebral cortex, and diffuse intense demyelination (dysmyelinating demyelination) of the cerebral white matter. (author)

  18. Thoracic computerized tomographic (CT findings in 2009 influenza A (H1N1 virus infection in Isfahan, Iran

    Directory of Open Access Journals (Sweden)

    Mojtaba Rostami

    2011-01-01

    Full Text Available Background: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1 in an appropriate clinical setting. Methods: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23 rd 2009 to February 20 th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1 virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. Results: Patchy infiltration (34.6%, lobar consolidation (30.8%, and interstitial infiltration (26.9% with airbronchogram (38.5% were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8% showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS. Conclusions: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1 in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific.

  19. Regional cerebral blood flow during rest and skilled hand movements by xenon-133 inhalation and emission computerized tomography

    DEFF Research Database (Denmark)

    Lauritzen, M; Henriksen, L; Lassen, N A

    1981-01-01

    Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating ("dynamic"), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1...... motor area on both sides by 34 +/- 15% (p less than 0.025)....

  20. Evaluation of quality of tomographs of Rio de Janeiro state, Brazil; Avaliacao da qualidade dos tomografos do estado do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Travassos, P.C.B.; Belem, V.R.; Magalhaes, L.A.; Almeida, C.E.A. de, E-mail: luisalexandregm@hotmail.com [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas

    2014-07-01

    Computerized tomographs used in 56 institutions in the state of Rio de Janeiro were evaluated. Criteria of image quality and dosimetry were submitted. The results showed that some not performed optimize their protocols examinations or perform wrongly, which results in an increase in the dose received by patients, and an image in compromised quality. (author)

  1. 2D histomorphometric quantification from 3D computerized tomography

    International Nuclear Information System (INIS)

    Lima, Inaya; Oliveira, Luis Fernando de; Lopes, Ricardo T.; Jesus, Edgar Francisco O. de; Alves, Jose Marcos

    2002-01-01

    In the present article, preliminary results are presented showing the application of the tridimensional computerized microtomographic technique (3D-μCT) to bone tissue characterization, through histomorphometric quantification which are based on stereologic concepts. Two samples of human bone were correctly prepared to be submitted to the tomographic system. The system used to realize that process were a radiographic system with a microfocus X-ray tube. Through these three processes, acquisition, reconstruction and quantification, it was possible to get the good results and coherent to the literature data. From this point, it is intended to compare these results with the information due the conventional method, that is, conventional histomorphometry. (author)

  2. Methodological study of radionuclide tomographic phase analysis in localization of accessory conduction pathway in patients with wolff-parkinson-white syndrome

    International Nuclear Information System (INIS)

    Wo Jinshan; Zhu Junren; Li Zhishan

    1994-01-01

    In this study, the methodology of tomographic phase analysis to detect the site of accessory conduction pathway (ACP) in patients with Wolff-Parkinson-White syndrome was presented. We analyzed the major factors that affect image reconstruction, selection of tomographic planes and phase analysis, also discussed the key step for reconstruction short-axial section that parallel and closest to the level of atrio-ventricular rings. Of five patients undergoing this procedure prior to surgery, tomographic phase analysis correctly identified the site of ACP confirmed by epicardial mapping in all of the five patients. Our results suggest this approach to be an objective, clear and correct one for localizing ACP

  3. Cognitive task analysis and the design of computerized operator aids

    International Nuclear Information System (INIS)

    Andersson, H.

    1985-01-01

    The new technological possibilities have led to the initiation of many projects for the design and evaluation of computerized operator support systems to be implemented in nuclear power plant control rooms. A typical finding so far has been that operators often have a positive attitude towards such systems but still don't use them very much, mostly because they find almost the same information on the conventional control boards which they are accustomed to use. Still, however, there is a widely shared belief that conventional control rooms have short-comings that make the use of computerized aids necessary. One reason for the limited success so far is that the new systems often are poorly integrated with the existing conventional instrumentation and with the working procedures. The reluctance to use new computer based aids, despite their nice features, is therefore probably caused by an inadequate task analysis made prior to the design of these computerized operator support systems

  4. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon [Dept. of Oral and Maxillofacial Radiology and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University, Chonju (Korea, Republic of); Park, Mi Ju [Dept. of Prosthodontics, School of Denstistry, Chonbuk National Universty, Chonju (Korea, Republic of)

    1999-08-15

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  5. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    International Nuclear Information System (INIS)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon; Park, Mi Ju

    1999-01-01

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  6. Laboratory Computerization: The Case for a Prospective Analysis

    OpenAIRE

    Hurdle, John F.; Schwamm, Harry A.

    1982-01-01

    The argument is made that computerization of a laboratory should be preceeded by a thorough prospective analysis of laboratory operations. Points to be pondered include complementation of retrospective data, system cost justification, system performance justification, post-installation personnel adjustments, improved system utilization, improved manual performance, and insight into “how much” system to buy. A brief, general outline is offered describing how to approach such a study.

  7. Diagnostic Value of Manual and Computerized Methods of Dental Casts Analysis

    Directory of Open Access Journals (Sweden)

    H. Rahimi

    2009-06-01

    Full Text Available Objective: The aim of this study was to evaluate the validity of computerized and manual methods of dental cast analysis.Materials and Methods: Twenty set-ups of upper and lower casts using artificial teeth corresponding to various malocclusions were created for a diagnostic in vitro study. Values of tooth size were calculated from the isolated artificial teeth out of the set-ups, results were considered as a gold standard for the tooth size. Arch width was calculated from the existing set-ups on the dentins.Impressions were taken of the casts with alginate and duplicated with dental stone. Models were measured with digital caliper manually. Then images were taken from the occlusal views of the casts by a digital camera. Measurements were done on digital images with the AutoCAD software.The results of the computerized and manual methods were compared with the gold standard.Intra class correlation coefficient of reliability was used to measure the accuracy ofthe methods and the Friedman technique used to evaluate the significance of differences.Results: Results indicated that all measurements were highly correlated, e.g. gold standard and manual (0.9613-0.9991, gold standard and computerized (0.7118-0.9883, manual and computerized (0.6734-0.9914. Statistically significant differences were present between these methods (P<0.05, but they proved not to be clinically significant.Conclusion: Manual measurement is still the most accurate method when compared to the computerized measurements and the results of measurement by computer should be interpreted with caution.

  8. Manual versus Automated Narrative Analysis of Agrammatic Production Patterns: The Northwestern Narrative Language Analysis and Computerized Language Analysis

    Science.gov (United States)

    Hsu, Chien-Ju; Thompson, Cynthia K.

    2018-01-01

    Purpose: The purpose of this study is to compare the outcomes of the manually coded Northwestern Narrative Language Analysis (NNLA) system, which was developed for characterizing agrammatic production patterns, and the automated Computerized Language Analysis (CLAN) system, which has recently been adopted to analyze speech samples of individuals…

  9. Study of the human encephalon morphology by computerized axial tomography in neurological diseases

    International Nuclear Information System (INIS)

    Loynaz Fernandez, Clara Silvia; Milan Companioni, Daile; Gomez Padron, Ivo; Alvarez Leon, Oladys; Espinosa Quiros, Desiderio

    2001-01-01

    Since the middle of the last century, the study of the human encephalon morphology has been of great interest for the researchers. With the introduction of the computerized axial tomography in 1974, it was possible to expand the knowledge about this area and at the same time provide information on the structural lesions that are pathologies of great psychosocial repercussion like epilepsy and Parkinsonism. This paper used 90 tomographic studies on people aged 20-80 years. A series of linear measurements were made and statistically processed. The results showed variations in linear measurements among control, epileptic and Parkinsonian subjects

  10. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  11. Technologies in computerized lexicography | Kruyt | Lexikos

    African Journals Online (AJOL)

    Although the topic of this paper is technology, focus is on functional rather than technical aspects of computerized lexicography. Keywords: computerized lexicography, electronic dictionary, electronic text corpus, lexicographer's workbench, integrated language database, automatic linguistic analysis, information retrieval, ...

  12. Estimating multi-phase pore-scale characteristics from X-ray tomographic data using cluster analysis-based segmentation

    DEFF Research Database (Denmark)

    Wildenschild, D.; Culligan, K.A.; Christensen, Britt Stenhøj Baun

    2006-01-01

    present in grey-scale X-ray tomographic images. The approach is based on a cluster analysis technique, used in combination with various other filtering and skeletonization schemes. We apply this segmentation algorithm to analyze multiphase pore-scale flow subjects such as hysteresis and interfacial...... characterization. The results clearly illustrate the advantage of using X-ray tomography together with cluster analysis-based image processing techniques. We were able to obtain detailed information on pore scale distribution of air and water phases, as well as quantitative measures of air bubble size and air...... of individual pores and interfaces. However, separation of the various phases (fluids and solids) in the grey-scale tomographic images has posed a major problem to quantitative analysis of the data. We present an image processing technique that facilitates identification and separation of the various phases...

  13. Computerized radionuclidic analysis in production facilities

    International Nuclear Information System (INIS)

    Gibbs, A.

    1978-03-01

    The Savannah River Plant Laboratories Department has been using a dual computer system to control all radionuclidic pulse height analyses since 1971. This computerized system analyzes 7000 to 8000 samples per month and has allowed the counting room staff to be reduced from three persons to one person. More reliable process information is being returned to the production facilities and for environmental evaluations and being returned faster, even though the sample load has more than tripled. This information is now more easily retrievable for other evaluations. The computer is also used for mass spectrometer data reduction and for quality control data analysis. The basic system is being expanded by interfacing microcomputers which provide data input from all of the laboratory modules for quality assurance programs

  14. Computerized tomography system

    International Nuclear Information System (INIS)

    Hellstrom, M.; Kutlik, E.; Perlin, A.

    1980-01-01

    A method for non-mechanically linking the motions of an x-ray source with an x-ray receptor during a tomographic procedure to produce a tomograph of a section of an object under examination comprising the steps of: effecting motion of said source and receptor to respective reference positions; thereafter during a tomographic procedural mode generating from at least one fixed frequency signal source first and second pulse trains, adapted to drive respective stepper motors, for effecting motion of said source and receptor, said pulse trains having a predetermined mathematical relationship dependent upon the desired fulcrum height of the tomographic section to be produced; and applying said first and second pulse trains to the respective stepper motors for a predetermined number of pulse counts to effect motion with respect to said respective reference positions and effecting a tomographic sweep thereby

  15. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  16. Health physics aspects of the EMI computerized tomography brain scanner

    International Nuclear Information System (INIS)

    Villafana, T.; Scouras, J.; Kirkland, L.; McElroy, N.; Paras, P.

    1978-01-01

    The EMI computerized tomographic cranial scanner is one of the first radiological systems incorporating an on-line computer. The result is an increase in the ability to visualize such tissues as grey matter and white matter as well as blood pools and tumor volumes. This advance has already begun to revolutionize radiological practice. Because of the totally different configuration of this unit, concern has been expressed over the dosages received by the patient, consequently the health physics aspects of this unit have been studied. Specifically, doses received by the surface of head and interior brain points as well as by the lens of the eye and gonads are reported here. X-ray output, beam half-value layers and barrier shielding requirements are also reported and discussed. (author)

  17. The Deference Due the Oracle: Computerized Text Analysis in a Basic Writing Class.

    Science.gov (United States)

    Otte, George

    1989-01-01

    Describes how a computerized text analysis program can help students discover error patterns in their writing, and notes how students' responses to analyses can reduce errors and improve their writing. (MM)

  18. A Procedure for the Computerized Analysis of Cleft Palate Speech Transcription

    Science.gov (United States)

    Fitzsimons, David A.; Jones, David L.; Barton, Belinda; North, Kathryn N.

    2012-01-01

    The phonetic symbols used by speech-language pathologists to transcribe speech contain underlying hexadecimal values used by computers to correctly display and process transcription data. This study aimed to develop a procedure to utilise these values as the basis for subsequent computerized analysis of cleft palate speech. A computer keyboard…

  19. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  20. Mobile 3D tomograph

    International Nuclear Information System (INIS)

    Illerhaus, Bernhard; Goebbels, Juergen; Onel, Yener; Sauerwein, Christoph

    2008-01-01

    Mobile tomographs often have the problem that high spatial resolution is impossible owing to the position or setup of the tomograph. While the tree tomograph developed by Messrs. Isotopenforschung Dr. Sauerwein GmbH worked well in practice, it is no longer used as the spatial resolution and measuring time are insufficient for many modern applications. The paper shows that the mechanical base of the method is sufficient for 3D CT measurements with modern detectors and X-ray tubes. CT measurements with very good statistics take less than 10 min. This means that mobile systems can be used, e.g. in examinations of non-transportable cultural objects or monuments. Enhancement of the spatial resolution of mobile tomographs capable of measuring in any position is made difficult by the fact that the tomograph has moving parts and will therefore have weight shifts. With the aid of tomographies whose spatial resolution is far higher than the mechanical accuracy, a correction method is presented for direct integration of the Feldkamp algorithm [de

  1. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhkio

    1985-03-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images.

  2. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhiko.

    1985-01-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images. (author)

  3. Cranial computerized tomography aspects of neuro-cysticercosis in infancy

    International Nuclear Information System (INIS)

    Guerreiro, M.M.; Facure, N.O.; Guerreiro, C.A.M.

    1989-01-01

    The analysis of 27 computed tomography scans (CT) is presented. Eighteen children were divided in three groups according to clinical and tomographic criteria. Group 1 was characterized mainly by epilepsy and calcifications. Group 2 was characterized by intracranial hypertension and several tomographic aspects: edema, cysts and nodules were seen in three patients; hydrocephaly and calcifications were seen in two patients and CT was normal is one patient. Group 3 had patients with epilepsy or headache and variable tomographic patterns. The results are discussed based on the available literature. (author)

  4. Estimation of spatial uncertainties of tomographic velocity models

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, M.; Du, Z.; Querendez, E. [SINTEF Petroleum Research, Trondheim (Norway)

    2012-12-15

    This research project aims to evaluate the possibility of assessing the spatial uncertainties in tomographic velocity model building in a quantitative way. The project is intended to serve as a test of whether accurate and specific uncertainty estimates (e.g., in meters) can be obtained. The project is based on Monte Carlo-type perturbations of the velocity model as obtained from the tomographic inversion guided by diagonal and off-diagonal elements of the resolution and the covariance matrices. The implementation and testing of this method was based on the SINTEF in-house stereotomography code, using small synthetic 2D data sets. To test the method the calculation and output of the covariance and resolution matrices was implemented, and software to perform the error estimation was created. The work included the creation of 2D synthetic data sets, the implementation and testing of the software to conduct the tests (output of the covariance and resolution matrices which are not implicitly provided by stereotomography), application to synthetic data sets, analysis of the test results, and creating the final report. The results show that this method can be used to estimate the spatial errors in tomographic images quantitatively. The results agree with' the known errors for our synthetic models. However, the method can only be applied to structures in the model, where the change of seismic velocity is larger than the predicted error of the velocity parameter amplitudes. In addition, the analysis is dependent on the tomographic method, e.g., regularization and parameterization. The conducted tests were very successful and we believe that this method could be developed further to be applied to third party tomographic images.

  5. Value of the computerized axial tomography for early diagnosis of cranio cerebral trauma

    International Nuclear Information System (INIS)

    Rodriguez Cheong, Maricel; Dosouto Infante, Vivian; Rosales Fargie, Yamile

    2010-01-01

    A descriptive and cross-sectional study was conducted in 62 patients with cranio cerebral trauma admitted to 'Saturnino Lora' Provincial Teaching Hospital of Santiago de Cuba, from January 2005 to May 2006, in whom computerized axial tomography indicated at the emergency room was performed with the purpose of evaluating the effectiveness of this radiographic technique for early diagnosis of the injury. In the case material there was neither association between the source and imaging results, nor between the age and sex. The main clinical manifestations were vomiting, headache and motor deficit as well as frontal location, intraparenchymatous hematoma (the latter as the most common image finding) and the hyperdense area as tomographic pattern. The survival was of 91,9%

  6. Castem 2000: a modern approach of computerized structural analysis

    International Nuclear Information System (INIS)

    Verpeaux, P.; Millard, A.; Hoffmann, A.; Ebersolt, L.

    1988-01-01

    Since the early beginning of the computerized structural analysis, many general purpose programs have been developed. Their complexity has increased rapidly and they became difficult to use and to maintain. The needs for an improved user's friendliness and the treatment of complex coupled problems have led to a modern tool: CASTEM 2000. It has profited by the general progress in computers technology and by a twenty years experience in large finite element codes. Its basic principles as well as examples of applications will be presented in this paper

  7. Advances in tomographic PIV

    NARCIS (Netherlands)

    Novara, M.

    2013-01-01

    This research deals with advanced developments in 3D particle image velocimetry based on the tomographic PIV technique (Tomo-PIV). The latter is a relatively recent measurement technique introduced by Elsinga et al. in 2005, which is based on the tomographic reconstruction of particle tracers in

  8. Computerized Italian criticality guide, description and validation

    International Nuclear Information System (INIS)

    Carotenuto, M.; Landeyro, P.A.

    1988-10-01

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  9. Computerized Italian criticality guide, description and validation

    Energy Technology Data Exchange (ETDEWEB)

    Carotenuto, M; Landeyro, P A [ENEA - Dipartimento Ciclo del Combustibile, Centro Ricerche Energia, Casaccia (Italy)

    1988-10-15

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  10. Computerized analysis of mammographic parenchymal patterns for assessing breast cancer risk: Effect of ROI size and location

    International Nuclear Information System (INIS)

    Li Hui; Giger, Maryellen L.; Huo Zhimin; Olopade, Olufunmilayo I.; Lan Li; Weber, Barbara L.; Bonta, Ioana

    2004-01-01

    The long-term goal of our research is to develop computerized radiographic markers for assessing breast density and parenchymal patterns that may be used together with clinical measures for determining the risk of breast cancer and assessing the response to preventive treatment. In our earlier studies, we found that women at high risk tended to have dense breasts with mammographic patterns that were coarse and low in contrast. With our method, computerized texture analysis is performed on a region of interest (ROI) within the mammographic image. In our current study, we investigate the effect of ROI size and ROI location on the computerized texture features obtained from 90 subjects (30 BRCA1/BRCA2 gene-mutation carriers and 60 age-matched women deemed to be at low risk for breast cancer). Mammograms were digitized at 0.1 mm pixel size and various ROI sizes were extracted from different breast regions in the craniocaudal (CC) view. Seventeen features, which characterize the density and texture of the parenchymal patterns, were extracted from the ROIs on these digitized mammograms. Stepwise feature selection and linear discriminant analysis were applied to identify features that differentiate between the low-risk women and the BRCA1/BRCA2 gene-mutation carriers. ROC analysis was used to assess the performance of the features in the task of distinguishing between these two groups. Our results show that there was a statistically significant decrease in the performance of the computerized texture features, as the ROI location was varied from the central region behind the nipple. However, we failed to show a statistically significant decrease in the performance of the computerized texture features with decreasing ROI size for the range studied

  11. Application of tomographic techniques to two-dimensional surface analysis using the Harwell nuclear microprobe

    International Nuclear Information System (INIS)

    Huddleston, J.; Hutchinson, I.G.; Pierce, T.B.

    1983-01-01

    Nuclear methods of surface analysis are discussed briefly, and the circumstances are described in which a two-dimensional analysis of the sample surface is desirable to enable the surface composition to be mapped accurately. Tomographic techniques of data manipulation are outlined. Data acquisition in the present case is performed by moving the sample in a defined sequence of positions, at each of which analytical data are gathered by the proton microprobe. The method and equipment are outlined. Data processing leading to the reconstruction of the image is summarised. (U.K.)

  12. Comparative study of the macroscopic finding, conventional tomographic imaging, and computed tomographic imaging in locating the mandibular canal

    International Nuclear Information System (INIS)

    Choi, Hang Moon; You, Dong Soo

    1995-01-01

    The purpose of this study was comparison of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and fitted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2 mm slice thickness and the sections were then radiographed (contact radiography). Each radiograpic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. The following results were obtained; 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6 mm difference between real values and radiographs 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within ±1 mm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibility was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  13. Computerized videodefecography versus defecography: do we need radiographs?

    Directory of Open Access Journals (Sweden)

    Carlos Walter Sobrado

    Full Text Available CONTEXT AND OBJECTIVE: Defecography has been recognized as a valuable method for evaluating patients with evacuation disorders. It consists of the use of static radiography and fluoroscopy to record different situations within anorectal dynamics. Conventionally, rectal parameters are measured using radiograms. It is rare for fluoroscopy alone to be used. Computer software has been developed with the specific aim of calculating these measurements from digitized videotaped images obtained during fluoroscopy, without the need for radiographic film, thereby developing a computerized videodefecography method. The objective was thus to compare measurements obtained via computerized videodefecography with conventional measurements and to discuss the advantages of the new method. DESIGN AND SETTING: Prospective study at the radiology service of Hospital das Clínicas, Universidade de São Paulo. METHOD: Ten consecutive normal subjects underwent videodefecography. The anorectal angle, anorectal junction, puborectalis muscle length, anal canal length and degree of anal relaxation were obtained via the conventional method (using radiography film and via computerized videodefecography using the ANGDIST software. Measurement and analysis of these parameters was performed by two independent physicians. RESULTS: Statistical analysis confirmed that the measurements obtained through direct radiography film assessment and using digital image analysis (computerized videodefecography were equivalent. CONCLUSIONS: Computerized videodefecography is equivalent to the traditional defecography examination. It has the advantage of offering reduced radiation exposure through saving on the use of radiography.

  14. Tomographic PIV: principles and practice

    International Nuclear Information System (INIS)

    Scarano, F

    2013-01-01

    A survey is given of the major developments in three-dimensional velocity field measurements using the tomographic particle image velocimetry (PIV) technique. The appearance of tomo-PIV dates back seven years from the present review (Elsinga et al 2005a 6th Int. Symp. PIV (Pasadena, CA)) and this approach has rapidly spread as a versatile, robust and accurate technique to investigate three-dimensional flows (Arroyo and Hinsch 2008 Topics in Applied Physics vol 112 ed A Schröder and C E Willert (Berlin: Springer) pp 127–54) and turbulence physics in particular. A considerable number of applications have been achieved over a wide range of flow problems, which requires the current status and capabilities of tomographic PIV to be reviewed. The fundamental aspects of the technique are discussed beginning from hardware considerations for volume illumination, imaging systems, their configurations and system calibration. The data processing aspects are of uppermost importance: image pre-processing, 3D object reconstruction and particle motion analysis are presented with their fundamental aspects along with the most advanced approaches. Reconstruction and cross-correlation algorithms, attaining higher measurement precision, spatial resolution or higher computational efficiency, are also discussed. The exploitation of 3D and time-resolved (4D) tomographic PIV data includes the evaluation of flow field pressure on the basis of the flow governing equation. The discussion also covers a-posteriori error analysis techniques. The most relevant applications of tomo-PIV in fluid mechanics are surveyed, covering experiments in air and water flows. In measurements in flow regimes from low-speed to supersonic, most emphasis is given to the complex 3D organization of turbulent coherent structures. (topical review)

  15. Software for tomographic analysis: application in ceramic filters

    International Nuclear Information System (INIS)

    Figuerola, W.B.; Assis, J.T.; Oliveira, L.F.; Lopes, R.T.

    2001-01-01

    New methods for acquiring data have been developed with the technological advances. With this, it has been possible to obtain more precise data and, consequently produce results with greater reliability. Among the variety of acquisition methods available, those that have volume description, as CT (Computerized Tomography) and NMR (Nuclear Magnetic Resonance) stand out. The models of volumetric data (group of data that describe a solid object from a three dimensional space) are being greatly used in diversity of areas as a way of inspection, modeling and simulation of objects in a three - dimensional space. Applications of this model are already found in Mechanic Engineering, Geosciences, Medicine and other areas. In the area of engineering it is sometimes necessary to use industrial CT as the only non-invasive form of inspection the interior of pieces without destroying them. The 3D micro focus X-ray tomography is one technique of non destructive testing used in the most different areas of science and technology, given its capacity to generate clean images (practically free of the unhappiness effect) and high resolution reconstructions. The unsharpness effect minimization and space resolution improvement are consequences of the focal spot size reduction in the X-ray micro focus tube to dimensions smaller than 50 mm. The ceramic filters are used in a wide area in the metallurgic industry, particularly in the cast aluminum where they are used to clean the waste coming through the liquid aluminum. The ceramic filters used in this work are manufactured by FUSICO (German company) and they are constructed from foams. They are manufactured at three models: 10, 20 and 30 ppi (porous per inch). In this paper we present the development of software to analyze and characterize ceramic filters, which can be divided in four stages. This software was developed in C++ language, using objects oriented programming. It is also capable of being executed in multiple platforms (Windows

  16. Clamshell tomograph

    International Nuclear Information System (INIS)

    Derenzo, S. E.; Budinger, Th. F.

    1984-01-01

    In brief, the invention is a tomograph modified to be in a clamshell configuration so that the ring or rings may be moved to multiple sampling positions. The tomograph includes an array of detectors arranged in successive adjacent relative locations along a closed curve in a first position in a selected plane, and means for securing the detectors in the relative locations in a first sampling position. The securing means is movable in the plane in two sections and pivotable at one point and only one point to enable movement of at least one of the sections to a second sampling position out of the closed curve so that the ends of the section which are opposite the point are moved apart a predetermined space

  17. A basic framework for the analysis of the human error potential due to the computerization in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Y. H.

    1999-01-01

    Computerization and its vivid benefits expected in the nuclear power plant design cannot be realized without verifying the inherent safety problems. Human error aspect is also included in the verification issues. The verification spans from the perception of the changes in operation functions such as automation to the unfamiliar experience of operators due to the interface change. Therefore, a new framework for human error analysis might capture both the positive and the negative effect of the computerization. This paper suggest a basic framework for error identification through the review of the existing human error studies and the experience of computerizations in nuclear power plants

  18. Age influence on attitudes of office workers faced with new computerized technologies: a questionnaire analysis.

    Science.gov (United States)

    Marquié, J C; Thon, B; Baracat, B

    1994-06-01

    The study of Bue and Gollac (1988) provided evidence that a significantly lower proportion of workers aged 45 years and over make use of computer technology compared with younger ones. The aim of the present survey was to explain this fact by a more intensive analysis of the older workers' attitude with respect to the computerization of work situations in relation to other individual and organizational factors. Six hundred and twenty office workers from 18 to 70 years old, either users or non-users of computerized devices, were asked to complete a questionnaire. The questions allowed the assessment of various aspects of the workers' current situation, such as the computer training they had received, the degree of consultation they were subjected to during the computerization process, their representation of the effects of these new technologies on working conditions and employment, the rate of use of new technologies outside the work context, and the perceived usefulness of computers for their own work. The analysis of the questionnaire revealed that as long as the step towards using computer tools, even minimally, has not been taken, then attitudes with respect to computerization are on the whole not very positive and are a source of anxiety for many workers. Age, and even more, seniority in the department, increase such negative representations. The effects of age and seniority were also found among users, as well as the effects of other factors such as qualification, education level, type and rate of computer use, and size of the firm. For the older workers, the expectation of less positive consequences for their career, or even the fear that computerization might be accompanied by threats to their own employment and the less clear knowledge of how computers operate, appeared to account for a significant part of the observed age and seniority differences in attitudes. Although the difference in the amount of computer training between age groups was smaller than

  19. Tomographic flow cytometry assisted by intelligent wavefronts analysis

    Science.gov (United States)

    Merola, F.; Memmolo, P.; Miccio, L.; Mugnano, M.; Ferraro, P.

    2017-06-01

    High-throughput single-cell analysis is a challenging target for implementing advanced biomedical applications. An excellent candidate for this aim is label-free tomographic phase microscopy. However, in-line tomography is very difficult to be implemented in practice, as it requires complex setup for rotating the sample and/or illuminate the cell along numerous directions [1]. We exploit random rolling of cells while they are flowing along a microfluidic channel demonstrating that it is possible to obtain in-line phase-contrast tomography by adopting strategies for intelligent wavefronts analysis thus obtaining complete retrieval of both 3D-position and orientation of rotating cells [2]. Thus, by numerical wavefront analysis a-priori knowledge of such information is no longer needed. This approach makes continuos-flow cyto-tomography suitable for practical operation in real-world, single-cell analysis and with substantial simplification of the optical system avoiding any mechanical/optical scanning of light source. Demonstration is given for different classes of biosamples, red-blood-cells (RBCs), diatom algae and fibroblast cells [3]. Accurate characterization of each type of cells is reported despite their very different nature and materials content, thus showing the proposed method can be extended, by adopting two alternate strategies of wavefront-analysis, to many classes of cells. In particular, for RBCs we furnish important parameters as 3D morphology, Corpuscular Hemoglobin (CH), Volume (V), and refractive index (RI) for each single cell in the total population [3]. This could open a new route in blood disease diagnosis, for example for the isolation and characterization of "foreign" cells in the blood stream, the so called Circulating Tumor Cells (CTC), early manifestation of metastasis.

  20. Computed tomographic appearances of sternocostoclavicular hyperostosis

    Energy Technology Data Exchange (ETDEWEB)

    Chigira, Masaki; Shimizu, Toru (Gunma Univ. (Japan). Dept. of Orthopaedic Surgery)

    1989-08-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG).

  1. Computed tomographic appearances of sternocostoclavicular hyperostosis

    International Nuclear Information System (INIS)

    Chigira, Masaki; Shimizu, Toru

    1989-01-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG)

  2. Three-dimensional analysis and display of medical images

    International Nuclear Information System (INIS)

    Bajcsy, R.

    1985-01-01

    Until recently, the most common medical images were X-rays on film analyzed by an expert, ususally a radiologist, who used, in addition to his/her visual perceptual abilities, knowledge obtained through medical studies, and experience. Today, however, with the advent of various imaging techniques, X-ray computerized axial tomographs (CAT), positron emission tomographs (PET), ultrasound tomographs, nuclear magnetic resonance tomographs (NMR), just to mention a few, the images are generated by computers and displayed on computer-controlled devices; so it is appropriate to think about more quantitative and perhaps automated ways of data analysis. Furthermore, since the data are generated by computer, it is only natural to take advantage of the computer for analysis purposes. In addition, using the computer, one can analyze more data and relate different modalities from the same subject, such as, for example, comparing the CAT images with PET images from the same subject. In the next section (The PET Scanner) the authors shall only briefly mention with appropriate references the modeling of the positron emission tomographic scanner, since this imaging technique is not as widely described in the literature as the CAT scanner. The modeling of the interpreter is not going to be mentioned, since it is a topic that by itself deserves a full paper; see, for example, Pizer [1981]. The thrust of this chapter is on modeling the organs that are being imaged and the matching techniques between the model and the data. The image data is from CAT and PET scans. Although the authors believe that their techniques are applicable to any organ of the human body, the examples are only from the brain

  3. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.

    Science.gov (United States)

    Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M

    2018-05-02

    Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm 2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (panalysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.

  4. Computed Tomographic Analysis of Ventral Atlantoaxial Optimal Safe Implantation Corridors in 27 Dogs.

    Science.gov (United States)

    Leblond, Guillaume; Gaitero, Luis; Moens, Noel M M; Zur Linden, Alex; James, Fiona M K; Monteith, Gabrielle J; Runciman, John

    2017-11-01

    Objectives  Ventral atlantoaxial stabilization techniques are challenging surgical procedures in dogs. Available surgical guidelines are based upon subjective anatomical landmarks, and limited radiographic and computed tomographic data. The aims of this study were (1) to provide detailed anatomical descriptions of atlantoaxial optimal safe implantation corridors to generate objective recommendations for optimal implant placements and (2) to compare anatomical data obtained in non-affected Toy breed dogs, affected Toy breed dogs suffering from atlantoaxial instability and non-affected Beagle dogs. Methods  Anatomical data were collected from a prospectively recruited population of 27 dogs using a previously validated method of optimal safe implantation corridor analysis using computed tomographic images. Results  Optimal implant positions and three-dimensional numerical data were generated successfully in all cases. Anatomical landmarks could be used to generate objective definitions of optimal insertion points which were applicable across all three groups. Overall the geometrical distribution of all implant sites was similar in all three groups with a few exceptions. Clinical Significance  This study provides extensive anatomical data available to facilitate surgical planning of implant placement for atlantoaxial stabilization. Our data suggest that non-affected Toy breed dogs and non-affected Beagle dogs constitute reasonable research models to study atlantoaxial stabilization constructs. Schattauer GmbH Stuttgart.

  5. Computerized adaptive testing item selection in computerized adaptive learning systems

    NARCIS (Netherlands)

    Eggen, Theodorus Johannes Hendrikus Maria; Eggen, T.J.H.M.; Veldkamp, B.P.

    2012-01-01

    Item selection methods traditionally developed for computerized adaptive testing (CAT) are explored for their usefulness in item-based computerized adaptive learning (CAL) systems. While in CAT Fisher information-based selection is optimal, for recovering learning populations in CAL systems item

  6. Quantitative analysis of normal thallium-201 tomographic studies

    International Nuclear Information System (INIS)

    Eisner, R.L.; Gober, A.; Cerqueira, M.

    1985-01-01

    To determine the normal (nl) distribution of Tl-201 uptake post exercise (EX) and at redistribution (RD) and nl washout, Tl-201 rotational tomographic (tomo) studies were performed in 40 subjects: 16 angiographic (angio) nls and 24 nl volunteers (12 from Emory and 12 from Yale). Oblique angle short axis slices were subjected to maximal count circumferential profile analysis. Data were displayed as a ''bullseye'' functional map with the apex at the center and base at the periphery. The bullseye was not uniform in all regions because of the variable effects of attenuation and resolution at different view angles. In all studies, the septum: lateral wall ratio was 1.0 in males and approximately equal to 1.0 in females. This occurred predominantly because of anterior defects due to breast soft tissue attenuation. EX and RD bullseyes were similar. Using a bi-exponential model for Tl kinetics, 4 hour normalized washout ranged 49-54% in each group and showed minimal variation between walls throughout the bullseye. Thus, there are well defined variations in Tl-201 uptake in the nl myocardium which must be taken into consideration when analyzing pt data. Because of these defects and the lack of adequate methods for attenuation correction, quantitative analysis of Tl-201 studies must include direct comparison with gender-matched nl data sets

  7. Radio tomographic imaging of sporadic-E layers during SEEK-2

    Directory of Open Access Journals (Sweden)

    P. A. Bernhardt

    2005-10-01

    Full Text Available During the SEEK-2 Rocket Campaign in August 2002, a Dual Band Beacon (DBB transmitting to Ground Receivers provided unique data on E-Region electron densities. Information from two rocket beacons and four ground receivers yielded multiple samples of E-region horizontal and vertical variations. The radio beacon measurements were made at four sites (Uchinoura, Tarumizu, Tanegashima, Takazaki in Japan for two rockets (S310-31 and S310-32 launched by the Institute of Space and Aeronautical Science (ISAS. Analysis was completed for four sets of beacon data to provide electron density images of sporadic-E layers. Signals from the two-frequency beacons on the SEEK-2 rockets were processed to yield total electron content (TEC data that was converted into electron density measurements. Wide variations in layer structures were detected. These included horizontal sporadic-E variations, vertical profiles of double, single, and weak layers. The radio beacon measurements were shown to be in agreement with the in-situ SEEK-2 sensors. The first tomographic image of a sporadic-E layer was produced from the data. The rocket beacon technique was shown to be an excellent tool to study sporadic-E layers because absolute TEC accuracy of 0.01 TEC Units can be easily obtained and, with proper receiver placement, electron density images can be produced using computerized ionospheric tomography with better than 1km horizontal and vertical resolution. Keywords. Ionospheric irregularities – Instruments and techniques – Mid-latitude ionosphere

  8. Human factor engineering analysis for computerized human machine interface design issues

    International Nuclear Information System (INIS)

    Wang Zhifang; Gu Pengfei; Zhang Jianbo

    2010-01-01

    The application of digital I and C technology in nuclear power plants is a significant improvement in terms of functional performances and flexibility, and it also poses a challenge to operation safety. Most of the new NPPs under construction are adopting advanced control room design which utilizes the computerized human machine interface (HMI) as the main operating means. Thus, it greatly changes the way the operators interact with the plant. This paper introduces the main challenges brought out by computerized technology on the human factor engineering aspect and addresses the main issues to be dealt with in the computerized HMI design process. Based on a operator task-resources-cognitive model, it states that the root cause of human errors is the mismatch between resources demand and their supply. And a task-oriented HMI design principle is discussed. (authors)

  9. Analysis and databasing software for integrated tomographic gamma scanner (TGS) and passive-active neutron (PAN) assay systems

    International Nuclear Information System (INIS)

    Estep, R.J.; Melton, S.G.; Buenafe, C.

    2000-01-01

    The CTEN-FIT program, written for Windows 9x/NT in C++,performs databasing and analysis of combined thermal/epithermal neutron (CTEN) passive and active neutron assay data and integrates that with isotopics results and gamma-ray data from methods such as tomographic gamma scanning (TGS). The binary database is reflected in a companion Excel database that allows extensive customization via Visual Basic for Applications macros. Automated analysis options make the analysis of the data transparent to the assay system operator. Various record browsers and information displays simplify record keeping tasks

  10. Tomographic imaging of matter using primary and secondary X-and gamma-radiation

    International Nuclear Information System (INIS)

    Holloway, I.E.

    1991-04-01

    Gamma rays may interact with matter by a variety of processes, many of which give rise to secondary radiations. This thesis examines the possibility of performing tomographic imaging by means of these secondary photons using low-cost apparatus. The techniques are compared with each other and with transmission tomography, which plays such an important role in modern diagnostic imaging. The progress of industrial tomography is reviewed as are techniques of investigation using gamma ray scattering in both industry and medicine. Some new applications of a simple gamma ray computerized tomography (CT) scanner have been performed. A method of determining the spatial distribution of pure beta emitters in matter by performing tomographic imaging using the bremsstrahlung radiation produced by the beta particles has been demonstrated. This technique has been shown to permit imaging at depths in material greatly exceeding the range of beta particles in matter. All the imaging techniques using secondary radiation have displayed two principal limitations: long scanning times and poor quantitative accuracy. The low scanning rate results from the small number of secondary photons that are detected. The major contributing factors to poor accuracy are attenuation and the noise produced by unwanted in-scattering. The possible applications for secondary photon imaging have been briefly outlined and some suggestions for future work are included. Although techniques based upon imaging using secondary radiation will not be able to compete with transmission CT in the vast majority of applications, they may prove valuable in a range of specialised fields. (author)

  11. A Novel Quantitative Computed Tomographic Analysis Suggests How Sirolimus Stabilizes Progressive Air Trapping in Lymphangioleiomyomatosis.

    Science.gov (United States)

    Argula, Rahul G; Kokosi, Maria; Lo, Pechin; Kim, Hyun J; Ravenel, James G; Meyer, Cristopher; Goldin, Jonathan; Lee, Hye-Seung; Strange, Charlie; McCormack, Francis X

    2016-03-01

    The Multicenter International Lymphangioleiomyomatosis Efficacy and Safety of Sirolimus (MILES) trial demonstrated that sirolimus stabilized lung function and improved measures of functional performance and quality of life in patients with lymphangioleiomyomatosis. The physiologic mechanisms of these beneficial actions of sirolimus are incompletely understood. To prospectively determine the longitudinal computed tomographic lung imaging correlates of lung function change in MILES patients treated with placebo or sirolimus. We determined the baseline to 12-month change in computed tomographic image-derived lung volumes and the volume of the lung occupied by cysts in the 31 MILES participants (17 in sirolimus group, 14 in placebo group) with baseline and 12-month scans. There was a trend toward an increase in median expiratory cyst volume percentage in the placebo group and a reduction in the sirolimus group (+2.68% vs. +0.97%, respectively; P = 0.10). The computed tomographic image-derived residual volume and the ratio of residual volume to total lung capacity increased more in the placebo group than in the sirolimus group (+214.4 ml vs. +2.9 ml [P = 0.054] and +0.05 ml vs. -0.01 ml [P = 0.0498], respectively). A Markov transition chain analysis of respiratory cycle cyst volume changes revealed greater dynamic variation in the sirolimus group than in the placebo group at the 12-month time point. Collectively, these data suggest that sirolimus attenuates progressive gas trapping in lymphangioleiomyomatosis, consistent with a beneficial effect of the drug on airflow obstruction. We speculate that a reduction in lymphangioleiomyomatosis cell burden around small airways and cyst walls alleviates progressive airflow limitation and facilitates cyst emptying.

  12. Design and development of computerized local and overall country's environmental data analysis network system

    International Nuclear Information System (INIS)

    Kim, Chang Gyu; Kang, Jong Gyu; Han, H.; Han, J. S.; Lee, Y. D.; Lee, S. R.; Kang, D. J.; Cho, Y. G.; Yun, S. H.

    2001-03-01

    In this development, we designed a integrated database for efficient data processing of radiation-environment data and developed the CLEAN (Computerized Local and overall country's Environmental data Analysis Network) system. The CLEAN system consists of local radiation-environment network, data analysis system, data open system. We developed the CLEAN system focused on building an integrated database, a data mart, and a CLEAN web site. It is expected that the developed system, which organizes the information related to environmental radiation data systematically, can be utilize for the accurate interpretation, analysis and evaluation

  13. Random signal tomographical analysis of two-phase flow

    International Nuclear Information System (INIS)

    Han, P.; Wesser, U.

    1990-01-01

    This paper reports on radiation tomography which is a useful tool for studying the internal structures of two-phase flow. However, general tomography analysis gives only time-averaged results, hence much information is lost. As a result, it is sometimes difficult to identify the flow regime; for example, the time-averaged picture does not significantly change as an annual flow develops from a slug flow. A two-phase flow diagnostic technique based on random signal tomographical analysis is developed. It extracts more information by studying the statistical variation of the measured signal with time. Local statistical parameters, including mean value, variance, skewness and flatness etc., are reconstructed from the information obtained by a general tomography technique. More important information are provided by the results. Not only the void fraction can be easily calculated, but also the flow pattern can be identified more objectively and more accurately. The experimental setup is introduced. It consisted of a two-phase flow loop, an X-ray system, a fan-like five-beam detector system and a signal acquisition and processing system. In the experiment, for both horizontal and vertical test sections (aluminum and steel tube with Di/Do = 40/45 mm), different flow situations are realized by independently adjusting air and water mass flow. Through a glass tube connected with the test section, some typical flow patterns are visualized and used for comparing with the reconstruction results

  14. Computerized spiral analysis using the iPad.

    Science.gov (United States)

    Sisti, Jonathan A; Christophe, Brandon; Seville, Audrey Rakovich; Garton, Andrew L A; Gupta, Vivek P; Bandin, Alexander J; Yu, Qiping; Pullman, Seth L

    2017-01-01

    Digital analysis of writing and drawing has become a valuable research and clinical tool for the study of upper limb motor dysfunction in patients with essential tremor, Parkinson's disease, dystonia, and related disorders. We developed a validated method of computerized spiral analysis of hand-drawn Archimedean spirals that provides insight into movement dynamics beyond subjective visual assessment using a Wacom graphics tablet. While the Wacom tablet method provides robust data, more widely available mobile technology platforms exist. We introduce a novel adaptation of the Wacom-based method for the collection of hand-drawn kinematic data using an Apple iPad. This iPad-based system is stand-alone, easy-to-use, can capture drawing data with either a finger or capacitive stylus, is precise, and potentially ubiquitous. The iPad-based system acquires position and time data that is fully compatible with our original spiral analysis program. All of the important indices including degree of severity, speed, presence of tremor, tremor amplitude, tremor frequency, variability of pressure, and tightness are calculated from the digital spiral data, which the application is able to transmit. While the iPad method is limited by current touch screen technology, it does collect data with acceptable congruence compared to the current Wacom-based method while providing the advantages of accessibility and ease of use. The iPad is capable of capturing precise digital spiral data for analysis of motor dysfunction while also providing a convenient, easy-to-use modality in clinics and potentially at home. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Tomographical properties of uniformly redundant arrays

    International Nuclear Information System (INIS)

    Cannon, T.M.; Fenimore, E.E.

    1978-01-01

    Recent work in coded aperture imaging has shown that the uniformly redundant array (URA) can image distant planar radioactive sources with no artifacts. The performance of two URA apertures when used in a close-up tomographic imaging system is investigated. It is shown that a URA based on m sequences is superior to one based on quadratic residues. The m sequence array not only produces less obnoxious artifacts in tomographic imaging, but is also more resilient to some described detrimental effects of close-up imaging. It is shown that in spite of these close-up effects, tomographic depth resolution increases as the source is moved closer to the detector

  16. Computerized analysis of fetal heart rate variability signal during the stages of labor.

    Science.gov (United States)

    Annunziata, Maria Laura; Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Giuliano, Natascia; Mereghini, Flavia; Di Lieto, Andrea; Campanile, Marta

    2016-03-01

    To analyze computerized cardiotocographic (cCTG) parameters (baseline fetal heart rate, baseline FHR; short term variability, STV; approximate entropy, ApEn; low frequency, LF; movement frequency, MF; high frequency, HF) in physiological pregnancy in order to correlate them with the stages of labor. This could provide more information for understanding the mechanisms of nervous system control of FHR during labor progression. A total of 534 pregnant women were monitored on cCTG from the 37th week before the onset of spontaneous labor and during the first and the second stage of labor. Statistical analysis was performed using Kruskal-Wallis test and Wilcoxon rank-sum test with the Bonferroni adjusted α (labor, and the first and second stages of labor. Differences between some of the stages were found for ApEn, LF and for LF/(HF + MF), where the first and the third were reduced and the second was increased. cCTG modifications during labor may reflect the physiologic increased activation of the autonomous nervous system. Using computerized fetal heart rate analysis during labor it may be possible to obtain more information from the fetal cardiac signal, in comparison with the traditional tracing. © 2016 Japan Society of Obstetrics and Gynecology.

  17. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  18. Computerized tomographic simulation compared with clinical mark-up in palliative radiotherapy: A prospective study

    International Nuclear Information System (INIS)

    Haddad, Peiman; Cheung, Fred; Pond, Gregory; Easton, Debbie; Cops, Frederick; Bezjak, Andrea; McLean, Michael; Levin, Wilfred; Billingsley, Susan; Williams, Diane; Wong, Rebecca

    2006-01-01

    Purpose To evaluate the impact of computed tomographic (CT) planning in comparison to clinical mark-up (CM) for palliative radiation of chest wall metastases. Methods and Materials In patients treated with CM for chest wall bone metastases (without conventional simulation/fluoroscopy), two consecutive planning CT scans were acquired with and without an external marker to delineate the CM treatment field. The two sets of scans were fused for evaluation of clinical tumor volume (CTV) coverage by the CM technique. Under-coverage was defined as the proportion of CTV not covered by the CM 80% isodose. Results Twenty-one treatments (ribs 17, sternum 2, and scapula 2) formed the basis of our study. Due to technical reasons, comparable data between CM and CT plans were available for 19 treatments only. CM resulted in a mean CTV under-coverage of 36%. Eleven sites (58%) had an under-coverage of >20%. Mean volume of normal tissues receiving ≥80% of the dose was 5.4% in CM and 9.3% in CT plans (p = 0.017). Based on dose-volume histogram comparisons, CT planning resulted in a change of treatment technique from direct apposition to a tangential pair in 7 of 19 cases. Conclusions CT planning demonstrated a 36% under-coverage of CTV with CM of ribs and chest wall metastases

  19. Emerging tomographic methods within the petroleum industry

    International Nuclear Information System (INIS)

    Johansen, Geir Anton

    2013-01-01

    Since industrial process tomography was introduced as a concept almost two decades ago, the considerable progress within a large variety of sensing modalities has to a large extent been technology driven. Industrial tomography applications may be divided into three categories: 1) Laboratory systems, 2) Field equipment for diagnostics and mapping purposes, and 3) Permanently installed systems. Examples on emerging methods on all categories will be presented, either from R and D at the University of Bergen and/or our industrial partners. Most developments are within the first category, where tomographs are used to provide better understanding of various processes such as pipe flow, separators, mixers and reactors. Here tomographic data is most often used to provide better process knowledge, for reference measurements and validation and development of process models, and finally for development for instruments and process equipment. The requirement here may be either high spatial resolution or high temporal resolution, or combinations of these. Tomographic field measurements are applied to either to inspect processes or equipment on a regular base or at faulty or irregular operation, or to map multicomponent systems such petroleum reservoirs, their structure and the distribution gas, oil and water within them. The latter will only be briefly touched upon here. Tomographic methods are increasingly being used for process and equipment diagnostics. The requirements vary and solutions based on repetition of single measurements, such as in column scanning, to full tomographic systems where there is sufficiently space or access. The third category is tomographic instruments that are permanently installed in situ in a process. These need not provide full tomographic images and instruments with fewer views are often preferred to reduce complexity and increase the instrument reliability. (author)

  20. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  1. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  2. Computer tomographic diagnosis of echinococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Haertel, M.; Fretz, C.; Fuchs, W.A.

    1980-08-01

    The computer tomographic appearances and differential diagnosis in 22 patients with echinococcosis are described; of these, twelve were of the cystic and ten of the alveolar type. The computer tomographic appearances are characterised by the presence of daughter cysts (66%) within the sharply demarkated parasitic cyst of water density. In the absence of daughter cysts, a definite aetiological diagnosis cannot be made, although there is a tendency to clasification of the occassionally multiple echinococcus cysts. The computer tomographic appearances of advanced alveolar echinococcosis are characterised by partial collequative necrosis, with clacification around the necrotic areas (90%). The absence of CT evidence of partial necrosis and calsification of the pseudotumour makes it difficult to establish a specific diagnosis. The conclusive and non-invasive character of the procedure and its reproducibility makes computer tomography the method of choice for the diagnosis and follow-up of echinococcosis.

  3. Computerized reactor monitor and control for nuclear reactors

    International Nuclear Information System (INIS)

    Buerger, L.

    1982-01-01

    The analysis of a computerized process control system developed by Transelektro-KFKI-Videoton (Hangary) for a twenty-year-old research reactor in Budapest and or a new one in Tajura (Libya) is given. The paper describes the computer hardware (R-10) and the implemented software (PROCESS-24K) as well as their applications at nuclear reactors. The computer program provides for man-machine communication, data acquisition and processing, trend and alarm analysis, the control of the reactor power, reactor physical calculations and additional operational functions. The reliability and the possible further development of the computerized systems which are suitable for application at reactors of different design are also discussed. (Sz.J.)

  4. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  5. The industrial computerized tomography applied to the rock analysis

    International Nuclear Information System (INIS)

    Tetzner, Guaraciaba de Campos

    2008-01-01

    This work is a study of the possibilities of the technical applications of Computerized Tomography (CT) by using a device developed in the Radiation Technology Center (CTR), Institute for Energy and Nuclear Research (IPEN-CNEN/SP). The equipment consists of a gamma radiation source ( 60 Co), a scintillation detector of sodium iodide doped with thallium (NaI (Tl)), a mechanical system to move the object (rotation and translation) and a computer system. This operating system has been designed and developed by the CTR-IPEN-CNEN/SP team using national resources and technology. The first validation test of the equipment was carried out using a cylindrical sample of polypropylene (phantom) with two cylindrical cavities (holes) of 5 x 25 cm (diameter and length). In these tests, the holes were filled with materials of different density (air, oil and metal), whose attenuation coefficients are well known. The goal of this first test was to assess the response quality of the equipment. The present report is a study comparing computerized tomography equipment CTR-IPEN-CNEN/SP which uses a source of gamma radiation ( 60 Co) and other equipment provided by the Department of Geosciences in the University of Texas (CTUT), which uses an X-ray source (450 kV and 3.2 mA). As a result, the images obtained and the comprehensive study of the usefulness of the equipment developed here strengthened the proposition that the development of industrial computerized tomography is an important step toward consolidating the national technology. (author)

  6. Computed tomographic analysis of temporal maxillary stability and pterygomaxillary generate formation following pediatric Le Fort III distraction advancement.

    Science.gov (United States)

    Hopper, Richard A; Sandercoe, Gavin; Woo, Albert; Watts, Robyn; Kelley, Patrick; Ettinger, Russell E; Saltzman, Babette

    2010-11-01

    Le Fort III distraction requires generation of bone in the pterygomaxillary region. The authors performed retrospective digital analysis on temporal fine-cut computed tomographic images to quantify both radiographic evidence of pterygomaxillary region bone formation and relative maxillary stability. Fifteen patients with syndromic midface hypoplasia were included in the study. The average age of the patients was 8.7 years; 11 had either Crouzon or Apert syndrome. The average displacement of the maxilla during distraction was 16.2 mm (range, 7 to 31 mm). Digital analysis was performed on fine-cut computed tomographic scans before surgery, at device removal, and at annual follow-up. Seven patients also had mid-consolidation computed tomographic scans. Relative maxillary stability and density of radiographic bone in the pterygomaxillary region were calculated between each scan. There was no evidence of clinically significant maxillary relapse, rotation, or growth between the end of consolidation and 1-year follow-up, other than a relatively small 2-mm subnasal maxillary vertical growth. There was an average radiographic ossification of 0.5 mm/mm advancement at the time of device removal, with a 25th percentile value of 0.3 mm/mm. The time during consolidation that each patient reached the 25th percentile of pterygomaxillary region bone density observed in this series of clinically stable advancements ranged from 1.3 to 9.8 weeks (average, 3.7 weeks). There was high variability in the amount of bone formed in the pterygomaxillary region associated with clinical stability of the advanced Le Fort III segment. These data suggest that a subsection of patients generate the minimal amount of pterygomaxillary region bone formation associated with advancement stability as early as 4 weeks into consolidation.

  7. Determining women's sexual self-schemas through advanced computerized text analysis.

    Science.gov (United States)

    Stanton, Amelia M; Boyd, Ryan L; Pulverman, Carey S; Meston, Cindy M

    2015-08-01

    The meaning extraction method (MEM), an advanced computerized text analysis technique, was used to analyze women's sexual self-schemas. Participants (n=239) completed open-ended essays about their personal feelings associated with sex and sexuality. These essays were analyzed using the MEM, a procedure designed to extract common themes from natural language. Using the MEM procedure, we extracted seven unique themes germane to sexual self-schemas: family and development, virginity, abuse, relationship, sexual activity, attraction, and existentialism. Each of these themes is comprised of frequently used words across the participants' descriptions of their sexual selves. Significant differences in sexual self-schemas were observed to covary with age, relationship status, and sexual abuse history. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  9. Tomographic visualization of stress corrosion cracks in tubing

    International Nuclear Information System (INIS)

    Morris, R.A.; Kruger, R.P.; Wecksung, G.W.

    1979-06-01

    A feasibility study was conducted to determine the possibility of detecting and sizing cracks in reactor cooling water tubes using tomographic techniques. Due to time and financial constraints, only one tomographic reconstruction using the best technique available was made. The results indicate that tomographic reconstructions can, in fact, detect cracks in the tubing and might possibly be capable of measuring the depth of the cracks. Limits of detectability and sensitivity have not been determined but should be investigated in any future work

  10. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems.

    Science.gov (United States)

    Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Dixit, Kratika; Naik, Saraswathi V

    2016-01-01

    Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. This is an experimental, in vitro study comparing the two groups. A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49.

  11. Tomographic method and apparatus

    International Nuclear Information System (INIS)

    Moore, R.M.

    1981-01-01

    A tomographic x-ray machine has a camera and film-plane section which move about a primary axis for imaging a selected cross-section of an anatomical member onto the film. A ''scout image'' of the member is taken at right angles to the plane of the desired cross-section to indicate the cross-section's angle with respect to the primary axis. The film plane is then located at the same angle with respect to a film cassette axis as the selected cross-section makes with the primary axis. The film plane and the cross-section are then maintained in parallel planes throughout motion of the camera and film plane during tomographic radiography. (author)

  12. Feasibility analysis of CNP 1000 computerized I and C system design objectives

    International Nuclear Information System (INIS)

    Zhang Mingguang; Xu Jijun; Zhang Qinshen

    2000-01-01

    The author states the design objectives of the computerized I and C (CIC) system and advanced main control room (AMCR), which could and should be achieved in CNP 1000, based on the national 1E computer production technology including software and hardware, and current instrumentation and control design technique of nuclear power plant. The feasibility analysis on the design objectives and the reasons or necessity to do the design research projects have been described. The objectives of design research on CIC and AMCR as well as the self-design proficiency after the design research have been given

  13. Tomographic extreme-ultraviolet spectrographs: TESS.

    Science.gov (United States)

    Cotton, D M; Stephan, A; Cook, T; Vickers, J; Taylor, V; Chakrabarti, S

    2000-08-01

    We describe the system of Tomographic Extreme Ultraviolet (EUV) SpectrographS (TESS) that are the primary instruments for the Tomographic Experiment using Radiative Recombinative Ionospheric EUV and Radio Sources (TERRIERS) satellite. The spectrographs were designed to make high-sensitivity {80 counts/s)/Rayleigh [one Rayleigh is equivalent to 10(6) photons/(4pi str cm(2)s)}, line-of-sight measurements of the oi 135.6- and 91.1-nm emissions suitable for tomographic inversion. The system consists of five spectrographs, four identical nightglow instruments (for redundancy and added sensitivity), and one instrument with a smaller aperture to reduce sensitivity and increase spectral resolution for daytime operation. Each instrument has a bandpass of 80-140 nm with approximately 2- and 1-nm resolution for the night and day instruments, respectively. They utilize microchannel-plate-based two-dimensional imaging detectors with wedge-and-strip anode readouts. The instruments were designed, fabricated, and calibrated at Boston University, and the TERRIERS satellite was launched on 18 May 1999 from Vandenberg Air Force Base, California.

  14. Precision of quantum tomographic detection of radiation

    Energy Technology Data Exchange (ETDEWEB)

    D' Ariano, G.M. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy) Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, Via A. Bassi 6, I-27100, Pavia (Italy)); Macchiavello, Chiara (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy)); Paris, M.G.A. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy))

    1994-11-21

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  15. Precision of quantum tomographic detection of radiation

    International Nuclear Information System (INIS)

    D'Ariano, G.M.; Macchiavello, Chiara; Paris, M.G.A.

    1994-01-01

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  16. Determining Women’s Sexual Self-Schemas Through Advanced Computerized Text Analysis

    Science.gov (United States)

    Stanton, Amelia M.; Boyd, Ryan L.; Pulverman, Carey S.; Meston, Cindy M.

    2015-01-01

    The meaning extraction method (MEM), an advanced computerized text analysis technique, was used to analyze women’s sexual self-schemas. Participants (n = 239) completed open-ended essays about their personal feelings associated with sex and sexuality. These essays were analyzed using the MEM, a procedure designed to extract common themes from natural language. Using the MEM procedure, we extracted seven unique themes germane to sexual self-schemas: family and development, virginity, abuse, relationship, sexual activity, attraction, and existentialism. Each of these themes is comprised of frequently used words across the participants’ descriptions of their sexual selves. Significant differences in sexual self-schemas were observed to covary with age, relationship status, and sexual abuse history. PMID:26146161

  17. Clinical study on primary epilepsy by computerized analysis of CT

    International Nuclear Information System (INIS)

    Tominaga, Hidefumi; Ueyama, Kenichi; Mizutani, Hiroshi; Imamura, Keisuke; Yoshidome, Kazushi; Matsumoto, Kei

    1985-01-01

    CT scans were examined by conventional linear measurement method and computerized analysis in 17 patients with primary epilepsy (Group A). Results were compared with those in healthy volunteers (Group B). Relationship between CT and EEG findings was also examined. The maximum width of the third cerebral ventricle (TCV) was narrowed in Group A than in Group B, with statistically significant difference. Low density rates (LDR) in Group A tended to be lower than those in Group B. There was significant difference in narrowed maximum width of TCV between Group A presenting with sudden dysrhythmia and Group B. For this type of Group A, LDR was significantly lower than that for Group B. These results suggest some changes in the brain in young epilepsy patients, especially those presenting with sudden dysrhythemia. (Namekawa, K.)

  18. Implementation of 3D tomographic visualisation through planar ICT data from experimental gamma-ray tomographic system

    International Nuclear Information System (INIS)

    Umesh Kumar; Singh, Gursharan; Ravindran, V.R.

    2001-01-01

    Industrial Computed Tomography (ICT) is one of the latest methods of non-destructive testing and examination. Different prototypes of Computed Industrial Tomographic Imaging System (CITIS) have been developed and experimental data have been generated in Isotope Applications Division. The experimental gamma-rays based tomographic imaging system comprises of beam generator containing approx. 220 GBq (6 Curies) of 137 Cs, a single NaI(Tl) -PMT integral assembly in a thick shielding and associated electronics, stepper motor controlled mechanical manipulator, collimators and required software. CITIS data is normally acquired in one orientation of the sample. It may be sometimes required to view a tomographic plane in a different orientation. Also, 3D visualization may be required with the available 2D data set. All these can be achieved by processing the available data. We have customized some of the routines for this purpose provided IDL (Integrated Data Language) package to suit our requirements. The present paper discusses methodology adopted for this purpose with an illustrative example. (author)

  19. Design and development of computerized local and overall country's environmental data analysis network system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Gyu; Kang, Jong Gyu; Han, H.; Han, J. S.; Lee, Y. D.; Lee, S. R.; Kang, D. J.; Cho, Y. G.; Yun, S. H. [Daedeok College, Taejon (Korea, Republic of)

    2001-03-15

    In this development, we designed a integrated database for efficient data processing of radiation-environment data and developed the CLEAN (Computerized Local and overall country's Environmental data Analysis Network) system. The CLEAN system consists of local radiation-environment network, data analysis system, data open system. We developed the CLEAN system focused on building an integrated database, a data mart, and a CLEAN web site. It is expected that the developed system, which organizes the information related to environmental radiation data systematically, can be utilize for the accurate interpretation, analysis and evaluation.

  20. An original emission tomograph for in vivo brain imaging of small animals

    International Nuclear Information System (INIS)

    Ochoa, A.V.; Ploux, L.; Mastrippolito, R.

    1996-01-01

    The principle of a new tomograph TOHR dedicated for small volume analysis with very high resolution is presented in this paper. We use uncorrelated multi-photons (X or gamma rays) radioisotopes and a large solid angle focusing collimator to make tomographic imaging without reconstruction algorithm. With this original device, detection efficiency and resolution are independent and submillimetric resolution can be achieved. A feasibility study shows that, made achieve the predicted performances of TOHR. We discuss its potential in rat brain tomography by simulating a realistic neuropharmacological experiment using a 1.4 mm resolution prototype of TOHR under development

  1. Computer tomographs

    International Nuclear Information System (INIS)

    Niedzwiedzki, M.

    1982-01-01

    Physical foundations and the developments in the transmission and emission computer tomography are presented. On the basis of the available literature and private communications a comparison is made of the various transmission tomographs. A new technique of computer emission tomography ECT, unknown in Poland, is described. The evaluation of two methods of ECT, namely those of positron and single photon emission tomography is made. (author)

  2. The use of tomographic techniques in the mineral processing Industry. A review

    International Nuclear Information System (INIS)

    Witika, L.K.; Jere, E.H.

    2002-01-01

    Process tomographic techniques may be used to analyse the internal state of most of the multiphase process engineering systems such as material segregation in a reactor multiphase flow in pipes and the spatial resolution of mineral grains in multiphase particles. These techniques include radiation computed tomography (X-ray or ray), electrical methods(capacitance, impedance and inductive tomography) positron emission tomography,optical tomography, microwave tomography, acoustic tomographical methods and many more. Many potential applications exist for process tomographic instrumentation for quantitative analysis and fault-detection purposes. Amongst these, electrical methods are widely used for those mineral processes deserving particular attention such as dense-medium separation, hydro cyclones, flotation cells and columns, gas-liquid absorbers, solvent extraction and other liquid-liquid processes, filtration and other solid-liquid processes, grinding mills (both dry and wet, conveyors and hoppers). Development in on-line measurement instrumentation now allow direct observation of the behaviour of fluids inside mineral separation equipment. This offers the possibility to acquire process data to enable models to be devised, to verify theoretical computational fluid dynamics predictions and control of various unit processes. In this review, the most important tomographic sensing methods are reviewed. Examples of the implementation of some electrical methods are illustrated. (authors)

  3. Computerizing primary schools in rural kenya

    DEFF Research Database (Denmark)

    Ogembo, J.G.; Ngugi, B.; Pelowski, Matthew John

    2012-01-01

    questions surrounding this endeavour. Specifically: 1.) what problems do rural schools actually want to solve with computerization; 2.) is computerization the most important priority for rural schools; 3.) are schools ready, in terms of infrastructure, for a computer in the classroom; or 4.) might...... and protective roofing -posing severe challenges to the outstanding conception of computerization. We consider these results and make recommendations for better adapting programs for computer introduction, and also suggest the use of new innovative devices, such as cell phones, which might already have overcome......This paper investigates the outstanding challenges facing primary schools' computerization in rural Kenya. Computerization of schools is often envisaged as a 'magic', or at least a particularly efficient, solution to many of the problems that developing countries face in improving primary school...

  4. Neurosurgical operating computerized tomographic scanner system. The CT scanner in the operating theater

    Energy Technology Data Exchange (ETDEWEB)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi

    1988-12-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place.

  5. Carotid ultrasonographic and brain computerized tomographic findings in patients with vascular ocular syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, Toshihiko; Matsushima, Chikage; Shimizu, Souichirou; Takasaki, Masaru; Iwasaki, Takuya; Usui, Masahiko [Tokyo Medical Coll. (Japan)

    2002-02-01

    To clarify the characteristics of cerebrovascular lesions in subtypes of vascular ocular syndrome, including amaurosis fugax (AF), retinal artery occlusion (RAO), and retinal vein occlusion (RVO), 93 patients with vascular ocular syndrome were studied by means of carotid ultrasonography (US) and brain computerized tomography (CT). The subjects comprised 21 patients with AF, 37 with RAO, and 35 with RVO who were sequentially given these diagnoses by the department of ophthalmology. On the basis of US findings, carotid lesions were defined as the presence of plaque or stenotic changes. CT findings were assessed for the presence and distribution of low-density areas (LDAs). Mean age was similar in each group, ranging from 64.5 to 67.4 years. The RAO group had high rates of men, hypertension, and smokers. US showed that the prevalence of carotid lesions ipsilateral to the affected eye was high in the RAO group and that severe stenosis and ulcerated plaque were present in 28.6% of the AF group and 45.9% of the RAO group. On CT examination, cerebral infarctions appeared as LDAs in about 10% of the patients in each group, and the incidence and distribution of LDAs were similar. Of 13 patients with cerebral infarction, only 2 were presumably due to carotid lesions; the others had a variety of causes. The discrepancy between US and CT findings was attributed to the small number of patients with cerebral infarction, since most patients had visual defects as an initial symptom. Our results suggest that extracranial carotid lesions, considered to be a major risk factor for stroke, should be carefully assessed in patients with AF or RAO to prevent further stroke. (author)

  6. Investigating Gravity Waves in Polar Mesospheric Clouds Using Tomographic Reconstructions of AIM Satellite Imagery

    Science.gov (United States)

    Hart, V. P.; Taylor, M. J.; Doyle, T. E.; Zhao, Y.; Pautet, P.-D.; Carruth, B. L.; Rusch, D. W.; Russell, J. M.

    2018-01-01

    This research presents the first application of tomographic techniques for investigating gravity wave structures in polar mesospheric clouds (PMCs) imaged by the Cloud Imaging and Particle Size instrument on the NASA AIM satellite. Albedo data comprising consecutive PMC scenes were used to tomographically reconstruct a 3-D layer using the Partially Constrained Algebraic Reconstruction Technique algorithm and a previously developed "fanning" technique. For this pilot study, a large region (760 × 148 km) of the PMC layer (altitude 83 km) was sampled with a 2 km horizontal resolution, and an intensity weighted centroid technique was developed to create novel 2-D surface maps, characterizing the individual gravity waves as well as their altitude variability. Spectral analysis of seven selected wave events observed during the Northern Hemisphere 2007 PMC season exhibited dominant horizontal wavelengths of 60-90 km, consistent with previous studies. These tomographic analyses have enabled a broad range of new investigations. For example, a clear spatial anticorrelation was observed between the PMC albedo and wave-induced altitude changes, with higher-albedo structures aligning well with wave troughs, while low-intensity regions aligned with wave crests. This result appears to be consistent with current theories of PMC development in the mesopause region. This new tomographic imaging technique also provides valuable wave amplitude information enabling further mesospheric gravity wave investigations, including quantitative analysis of their hemispheric and interannual characteristics and variations.

  7. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  8. Computerized photogrammetry used to calculate the brow position index.

    Science.gov (United States)

    Naif-de-Andrade, Naif Thadeu; Hochman, Bernardo; Naif-de-Andrade, Camila Zirlis; Ferreira, Lydia Masako

    2012-10-01

    The orbital region is of vital importance to facial expression. Brow ptosis, besides having an impact on facial harmony, is a sign of aging. Various surgical techniques have been developed to increase the efficacy of brow-lift surgery. However, no consensus method exists for an objective measurement of the eyebrow position due to the curvature of the face. Therefore, this study aimed to establish a method for measuring the eyebrow position using computerized photogrammetry. For this study, 20 orbital regions of 10 volunteers were measured by direct anthropometry using a digital caliper and by indirect anthropometry (computerized photogrammetry) using standardized digital photographs. Lines, points, and distances were defined based on the position of the anthropometric landmarks endocanthion and exocanthion and then used to calculate the brow position index (BPI). Statistical analysis was performed using Student's t test with a significance level of 5 %. The BPI values obtained by computerized photogrammetric measurements did not differ significantly from those obtained by direct anthropometric measurements (p > 0.05). The mean BPI was 84.89 ± 10.30 for the computerized photogrammetric measurements and 85.27 ± 10.67 for the direct anthropometric measurements. The BPI defined in this study and obtained by computerized photogrammetry is a reproducible and efficient method for measuring the eyebrow position. This journal requires that authors assign a level of evidence to each article.

  9. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    A tomographic array with the following characteristics is described. An X-ray screen serving as detector is placed before a photomultiplier tube which itself is placed in front of a television camera connected to a set of image processors. The detector is concave towards the source and is replacable. Different images of the object are obtained simultaneously. Optical fibers and lenses are used for transmission within the system

  10. A positron emission tomograph designed for 3/4 mm resolution

    International Nuclear Information System (INIS)

    McInytre, J.A.; Allen, R.D.; Aguiar, J.; Paulson, J.T.

    1995-01-01

    Two factors of the design for a positron tomograph affect the magnitude of the tomograph spatial resolution: the gamma ray detector width and the analogue measurement of the scintillator location. In the tomograph design reported here the analogue measurement is eliminated and the detector transaxial width factor is reduced to 3/4 mm. The analogue measurement is eliminated by transmitting the scintillation light from each individual scintillator through optical fibers to four photo-multipliers (PMT's); the identities of the PMT's then provide a digital address for the scintillation location. Plastic scintillators are used to provide enough scintillation light for transmission through the optical fibers. Bonuses from the use of plastic scintillators are first, the reduction of the scintillator dead time to about 10 nsec, second, a large reduction of cross-talk between neighboring scintillators, third, the reduction of resolution loss from off-axis gamma rays and, fourth, the ability to sample the axial image at one-eighth the axial resolution distance of 2.5 mm. The designed tomograph incorporates 20 rings. Two of the 32 tomograph 20-ring modules have been constructed to measure the resolution and other characteristics of the tomographs

  11. Tomographic anthropomorphic models. Pt. 2. Organ doses from computed tomographic examinations in paediatric radiology

    International Nuclear Information System (INIS)

    Zankl, M.; Panzer, W.; Drexler, G.

    1993-11-01

    This report provides a catalogue of organ dose conversion factors resulting from computed tomographic (CT) examinations of children. Two radiation qualities and two exposure geometries were simulated as well as the use of asymmetrical beams. The use of further beam shaping devices was not considered. The organ dose conversion factors are applicable to babies at the age of ca. 2 months and to children between 5 and 7 years but can be used for other ages as well with the appropriate adjustments. For the calculations, the patients were represented by the GSF tomographic anthropomorphic models BABY and CHILD. The radiation transport in the body was simulated using a Monte Carlo method. The doses are presented as conversion factors of mean organ doses per air kerma free in air on the axis of rotation. Mean organ dose conversion factors are given per organ and per scanned body section of 1 cm height. The mean dose to an organ resulting from a particular CT examination can be estimated by summing up the contributions to the organ dose from all relevant sections. To facilitate the selection of the appropriate sections, a table is given which relates the tomographic models' coordinates to certain anatomical landmarks in the human body. (orig.)

  12. Introduction to curved rotary tomographic apparatus 'TOMOREX'

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Shinojima, Masayasu; Kohirasawa, Hideo; Tokui, Mitsuru

    1980-01-01

    In recent years, panorama X-ray photographic method is widely used for the X-ray diagnosis of teeth, jawbones and faces. One type based on the principle of tomography is curved surface rotary tomographic method utilizing fine-gap X-ray beam. With the synchronous rotation of an X-ray tube and a photographic film around a face, describing a U-shaped tomographic plane along a dental arch, an upper or lower jawbone is photographed. In the ''TOMOREX'' belonging to this type, is different tomographic planes are available, so that by selecting any position in advance, the part can be photographed. Furthermore, patients can be subjected to examination as laid on a stretcher. The mechanism and equipment, and the photographic method for eye sockets, cheekbones, upper jaw cavities and stereoscopic images are described. (J.P.N.)

  13. Tomographic thallium-201 myocardial perfusion scintigrams after maximal coronary artery vasodilation with intravenous dipyridamole: comparison of qualitative and quantitative approaches

    International Nuclear Information System (INIS)

    Francisco, D.A.; Collins, S.M.; Go, R.T.; Ehrhardt, J.C.; Van Kirk, O.C.; Marcus, M.L.

    1982-01-01

    Eighty-six patients had thallium-201 ( 201 Tl) myocardial perfusion scintigrams after intense coronary artery dilation with i.v. dipyridamole. Tomographic and planar 201 Tl scintigrams were obtained in each patient. Tomographic scintigrams were interpreted using quantitative or visual criteria; planar scintigrams were assessed using visual criteria only. When visual criteria were used, interobserver variability was 40% for tomographic scintigrams and 44% for planar scintigrams. In the 24 patients with normal or nonsignificant CAD, quantitative analysis of the tomograms (range approach) indicated that one of 24 (4%) had a positive image (specificity 96%%); in contrast, when visual criteria were used to interpret the tomographic or planar 201 Tl scintigrams, eight of 24 (33%) had positive scintigrams (specificity 67%). In the 51 abnormal patients, the sensitivity of detecting CAD was 46 of 51 (90%) for tomographic scintigrams interpreted quantitatively, 39 of 51 (76%) for tomographic scintigrams interpreted visually and 41 of 51 (80%) for planar scintigrams assessed visually. The tomographic imaging procedure (quantitative interpretation) also demonstrated a high sensitivity (89%) and specificity (100%) in 28 patients (10 normal and 18 CAD), with a clinical diagnosis of unstable angina pectoris. Overall, the predictive accuracy of an abnormal scintigram with quantitative tomographic imaging (98%) was significantly better (p<0.05) than either qualitative planar or pinhole imaging

  14. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration of a tomographic array in which the object can rotate about its axis is described. The X-ray detector is a cylindrical screen perpendicular to the axis of rotation. The X-ray source has a line-shaped focus coinciding with the axis of rotation. The beam is fan-shaped with one side of this fan lying along the axis of rotation. The detector screen is placed inside an X-ray image multiplier tube

  15. Computerized adaptive testing in computer assisted learning?

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; Eggen, Theodorus Johannes Hendrikus Maria; De Wannemacker, Stefan; Clarebout, Geraldine; De Causmaecker, Patrick

    2011-01-01

    A major goal in computerized learning systems is to optimize learning, while in computerized adaptive tests (CAT) efficient measurement of the proficiency of students is the main focus. There seems to be a common interest to integrate computerized adaptive item selection in learning systems and

  16. Terahertz wave tomographic imaging with a Fresnel lens

    Institute of Scientific and Technical Information of China (English)

    S. Wang; X.-C. Zhang

    2003-01-01

    We demonstrate three-dimensional tomographic imaging using a Fresnel lens with broadband terahertz pulses. Objects at various locations along the beam propagation path are uniquely imaged on the same imaging plane using a Fresnel lens with different frequencies of the imaging beam. This procedure allows the reconstruction of an object's tomographic contrast image by assembling the frequency-dependent images.

  17. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  18. Industrial dynamic tomographic reconstruction

    International Nuclear Information System (INIS)

    Oliveira, Eric Ferreira de

    2016-01-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  19. Relation of the measuring values in cephalometric radiographs and TMJ tomographs

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jin Woo [Kangnung National Univ. College of Dentistry, Kangnung (Korea, Republic of)

    2007-03-15

    To examine whether the maxillofacial skeletal morphology correlates with the condylar position and the anatomic characteristics of articular eminence using measurements of lateral cephalometric radiographs and individualized sagittal temporomandibular joint (TMJ) tomographs. I compared measurements of 202 TMJs of 101 orthodontic patients of Kangnung National University Dental Hospital. I used Pearson's correlation for comparison of the measuring values in lateral cephalometric radiographs and individualized sagittal TMJ tomographs. Large occlusal plane angle tendency showed decreased width of posterior eminence slope, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large mandibular plane angle tendency showed decreased superior joint space, decreased superior joint space, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large genial angle tendency showed decreased depth of articular fossa, decreased posterior slope angle of eminence and anterior position of comdylar head. Large anterior facial height and large posterior facial height tendency showed increased width of posterior position of condylar head. Maxillofacial skeletal morphology has correlation with the anatomic characteristics of TMJ. Individualized sagittal TMJ tomographs can provide useful information for anatomical analysis of TMJ.

  20. Visual and semiquantitative analysis of 18F-fluorodeoxyglucose positron emission tomography using a partial-ring tomograph without attenuation correction to differentiate benign and malignant pulmonary nodules

    International Nuclear Information System (INIS)

    Skehan, S.J.; Coates, G.; Otero, C.; O'Donovan, N.; Pelling, M.; Nahmias, C.

    2001-01-01

    Many studies have reported the use of attenuation-corrected positron emission tomography with 18 F-fluorodeoxyglucose (FDG PET) with full-ring tomographs to differentiate between benign and malignant pulmonary nodules. We sought to evaluate FDG PET using a partial-ring tomograph without attenuation correction. A retrospective review of PET images from 77 patients (range 38-84 years of age) with proven benign or malignant pulmonary nodules was undertaken. All images were obtained using a Siemens/CTI ECAT ART tomograph, without attenuation correction, after 185 MBq 18 F-FDG was injected. Images were visually graded on a 5-point scale from 'definitely malignant' to 'definitely benign,' and lesion-to-background (LB) ratios were calculated using region of interest analysis. Visual and semiquantitative analyses were compared using receiver operating characteristic analysis. Twenty lesions were benign and 57 were malignant. The mean LB ratio for benign lesions was 1.5 (range 1.0-5.7) and for malignant lesions 5.7 (range 1.2-14.1) (p < 0.001). The area under the ROC curve for LB ratio analysis was 0.95, and for visual analysis 0.91 (p = 0.39). The optimal cut-off ratio with LB ratio analysis was 1.8, giving a sensitivity of 95% and a specificity of 85%. For lesions thought to be 'definitely malignant' on visual analysis, the sensitivity was 93% and the specificity 85%. Three proven infective lesions were rated as malignant by both techniques (LB ratio 2.6-5.7). FDG PET without attenuation correction is accurate for differentiating between benign and malignant lung nodules. Results using simple LB ratios without attenuation correction compare favourably with the published sensitivity and specificity for standard uptake ratios. Visual analysis is equally accurate. (author)

  1. A 3D tomographic EBSD analysis of a CVD diamond thin film

    International Nuclear Information System (INIS)

    Liu Tao; Raabe, Dierk; Zaefferer, Stefan

    2008-01-01

    We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

  2. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    Science.gov (United States)

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  3. Arbitrary layer tomographic method and apparatus

    International Nuclear Information System (INIS)

    Kato, H.; Ishida, M.

    1984-01-01

    Many two-dimensional X-ray projection distribution images obtained by exposing an object to X-rays in various directions are once stored in positions different from one another in a stimulable phosphor sheet or respectively in many stimulable phosphor sheets. The stimulable phosphor sheet or sheets are then scanned with stimulating rays, and the light emitted thereby from the stimulable phosphor sheet or sheets is photoelectrically read out to obtain electric signals representing the X-ray projection distribution images. The electric signals are processed to obtain a tomographic image of an arbitrary tomographic layer of the object

  4. Nuclear Computerized Library for Assessing Reactor Risk (NUCLARR)

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Blackman, H.S.; Ryan, T.G.

    1986-01-01

    The Nuclear Computerized Library for Assessing Reactor Risk (NUCLARR) program is a multiyear effort sponsored by the NRC and is being conducted at the Idaho National Engineering Laboratory (INEL). The goal of this program is to establish and operate computerized data base management tools for the human reliability data bank specification developed by Comer and Donovan. The NRC and the risk analysis community recognized that implementing a fully functional library would not be feasible, or practical, without the aid of computerized tools for management and manipulation of its data sources. The end users of the NUCLARR can be classified into three categories according to specific needs. The first category is those users interested in reviewing individual data sources for a given situation. The second category of users selects multiple data sources for a specific case, summarizing the information, and performing comparative studies. The last category of users interfaces the NUCLARR with other programming applications, such as other data banks, and simulation models of risk assessment. Project status is provided in the paper

  5. Gamma Ray Tomographic Scan Method for Large Scale Industrial Plants

    International Nuclear Information System (INIS)

    Moon, Jin Ho; Jung, Sung Hee; Kim, Jong Bum; Park, Jang Geun

    2011-01-01

    The gamma ray tomography systems have been used to investigate a chemical process for last decade. There have been many cases of gamma ray tomography for laboratory scale work but not many cases for industrial scale work. Non-tomographic equipment with gamma-ray sources is often used in process diagnosis. Gamma radiography, gamma column scanning and the radioisotope tracer technique are examples of gamma ray application in industries. In spite of many outdoor non-gamma ray tomographic equipment, the most of gamma ray tomographic systems still remained as indoor equipment. But, as the gamma tomography has developed, the demand on gamma tomography for real scale plants also increased. To develop the industrial scale system, we introduced the gamma-ray tomographic system with fixed detectors and rotating source. The general system configuration is similar to 4 th generation geometry. But the main effort has been made to actualize the instant installation of the system for real scale industrial plant. This work would be a first attempt to apply the 4th generation industrial gamma tomographic scanning by experimental method. The individual 0.5-inch NaI detector was used for gamma ray detection by configuring circular shape around industrial plant. This tomographic scan method can reduce mechanical complexity and require a much smaller space than a conventional CT. Those properties make it easy to get measurement data for a real scale plant

  6. Tomographic Approach in Three-Orthogonal-Basis Quantum Key Distribution

    International Nuclear Information System (INIS)

    Liang Wen-Ye; Yin Zhen-Qiang; Chen Hua; Li Hong-Wei; Chen Wei; Han Zheng-Fu; Wen Hao

    2015-01-01

    At present, there is an increasing awareness of some three-orthogonal-basis quantum key distribution protocols, such as, the reference-frame-independent (RFI) protocol and the six-state protocol. For secure key rate estimations of these protocols, there are two methods: one is the conventional approach, and another is the tomographic approach. However, a comparison between these two methods has not been given yet. In this work, with the general model of rotation channel, we estimate the key rate using conventional and tomographic methods respectively. Results show that conventional estimation approach in RFI protocol is equivalent to tomographic approach only in the case of that one of three orthogonal bases is always aligned. In other cases, tomographic approach performs much better than the respective conventional approaches of the RFI protocol and the six-state protocol. Furthermore, based on the experimental data, we illustrate the deep connections between tomography and conventional RFI approach representations. (paper)

  7. Design of aerosol face masks for children using computerized 3D face analysis.

    Science.gov (United States)

    Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Raviv, Dan; Kimmel, Ron; Waisman, Dan; Newhouse, Michael T

    2014-08-01

    Aerosol masks were originally developed for adults and downsized for children. Overall fit to minimize dead space and a tight seal are problematic, because children's faces undergo rapid and marked topographic and internal anthropometric changes in their first few months/years of life. Facial three-dimensional (3D) anthropometric data were used to design an optimized pediatric mask. Children's faces (n=271, aged 1 month to 4 years) were scanned with 3D technology. Data for the distance from the bridge of the nose to the tip of the chin (H) and the width of the mouth opening (W) were used to categorize the scans into "small," "medium," and "large" "clusters." "Average" masks were developed from each cluster to provide an optimal seal with minimal dead space. The resulting computerized contour, W and H, were used to develop the SootherMask® that enables children, "suckling" on their own pacifier, to keep the mask on their face, mainly by means of subatmospheric pressure. The relatively wide and flexible rim of the mask accommodates variations in facial size within and between clusters. Unique pediatric face masks were developed based on anthropometric data obtained through computerized 3D face analysis. These masks follow facial contours and gently seal to the child's face, and thus may minimize aerosol leakage and dead space.

  8. Diversity in computerized reactor protection systems

    International Nuclear Information System (INIS)

    Fischer, H.D.; Piel, L.

    1999-01-01

    Based on engineering judgement, the most important measures to increase the independency of redundant trains of a computerized safety instrumentation and control system (I and C) in a nuclear power plant are evaluated with respect to practical applications. This paper will contribute to an objective discussion on the necessary and justifiable arrangement of diversity in a computerized safety I and C system. Important conclusions are: - (i) diverse equipment may be used to control dependent failures only if measures necessary for designing, licensing, and operating a computerized safety I and C system homogeneous in equipment are neither technically nor economically feasible; - (ii) the considerable large operating experience in France with a non-diverse equipment digital reactor protection system does not call for equipment diversity. Although there are no generally accepted methods, the licensing authority is still required to take into account dependent failures in a probabilistic safety analysis; - (ii) the frequency of postulated initiating events implies which I and C functionality should be implemented on diverse equipment. Using non-safety I and C equipment in addition to safety I and C equipment is attractive because its necessary unavailability to control an initiating event in teamwork with the safety I and C equipment is estimated to range from 0.01 to 0.1. This can be achieved by operational experience

  9. Clinical and computerized tomographic studies of chronic subdural hematomas

    International Nuclear Information System (INIS)

    Naito, Takahiro; Maegawa, Mototsugu; Morimoto, Tetsuya; Sakaki, Toshisuke; Tanikake, Tatsuo

    1981-01-01

    The authors' experience is based on 84 patients with chronic subdural hematomas verified by surgery. Analysis of CT findings of the chronic subdural hematoma led to a classification of four different types: low, iso-, mixed and high density. The mixed density type was classified into two subdivisions: Type I characterized by the sharp border between two compartments and Type II characterized by high density around the hematoma capsule. There was tendency in the high density type group for the clinical course from onset to be the most rapid, the mass effect for the brain the strongest and the period from onset to surgical intervention the shortest. They were slower, weaker and longer in order of the mixed, iso- and low density types. As a result of analysis of hematoma content, there was no correlation among Ca ion concentration, total protein volume and types of hematoma, but there were some significant correlations among hemoglobin, hematocrit and types of hematoma. Hemoglobin and hematocrit were highest in hematoma content of the high density type and were lower in the order of the high density part of the mixed density type, isodensity type and low density type. However, the hematoma content in the low density type showed the highest value of LDH. (author)

  10. A 3D tomographic EBSD analysis of a CVD diamond thin film

    Directory of Open Access Journals (Sweden)

    Tao Liu, Dierk Raabe and Stefan Zaefferer

    2008-01-01

    Full Text Available We have studied the nucleation and growth processes in a chemical vapor deposition (CVD diamond film using a tomographic electron backscattering diffraction method (3D EBSD. The approach is based on the combination of a focused ion beam (FIB unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

  11. Computed tomographic findings of intracranial pyogenic abscess

    International Nuclear Information System (INIS)

    Kim, S. J.; Suh, J. H.; Park, C. Y.; Lee, K. C.; Chung, S. S.

    1982-01-01

    The early diagnosis and effective treatment of brain abscess pose a difficult clinical problem. With the advent of computed tomography, however, it appears that mortality due to intracranial abscess has significantly diminished. 54 cases of intracranial pyogenic abscess are presented. Etiologic factors and computed tomographic findings are analyzed and following result are obtained. 1. The common etiologic factors are otitis media, post operation, and head trauma, in order of frequency. 2. The most common initial computed tomographic findings of brain abscess is ring contrast enhancement with surrounding brain edema. 3. The most characteristic computed tomographic finding of ring contrast enhancement is smooth thin walled ring contrast enhancement. 4. Most of thick irregular ring contrast enhancement are abscess associated with cyanotic heart disease or poor operation. 5. The most common findings of epidural and subdural empyema is crescentic radiolucent area with thin wall contrast enhancement without surrounding brain edema in convexity of brain

  12. Analysis of errors during medical and computerized diagnostics of spherical lung neoplasms

    International Nuclear Information System (INIS)

    Pozmogov, A.I.; Petruk, D.A.

    1985-01-01

    Reasons for errors in medical and computerized diagnostics of spherical lung neoplasms are studied based on material of 212 case records and clinicoroentgenological data; it should promote improvement of their diagnostics

  13. Formal Verification of Computerized Procedure with Colored Petri Nets

    International Nuclear Information System (INIS)

    Kim, Yun Goo; Shin, Yeong Cheol

    2008-01-01

    Computerized Procedure System (CPS) supports nuclear power plant operators in performing operating procedures which are instructions to guide in monitoring, decision making and controlling nuclear power plants. Computerized Procedure (CP) should be loaded to CPS. Due to its execution characteristic, computerized procedure acts like a software in CPS. For example, procedure flows are determined by operator evaluation and computerized procedure logic which are pre-defined. So the verification of Computerized Procedure logic and execution flow is needed before computerized procedures are installed in the system. Formal verification methods are proposed and the modeling of operating procedures with Coloured Petri Nets(CP-nets) is presented

  14. [Computerized medical record: deontology and legislation].

    Science.gov (United States)

    Allaert, F A; Dusserre, L

    1996-02-01

    Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.

  15. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  16. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka

    1980-01-01

    The authors constructed a Multiple Pinhole Coded Aperture (MPCA) and developed related decoding software. When simple coordinate transformation was performed, omission of points and shifting of counts occurred. By selecting various tomographic planes and collecting count for each tomographic depth from the shadowgram, a solution to these problems was found. The counts from the central portion of the tomographic image from the MPCA were incorrectly high, this was rectified by a correction function to improve the uniformity correction program of the γ-camera. Depth resolution of the tomographic image improved in proportion to the area encompassed by the pinhole configuration. An MPCA with a uniform arrangement of pinholes (e, g, pinholes in an arrangement parallel to the X-axis or the Y-axis) yielded decoded tomographic images of inferior quality. Optimum results were obtained with a ring-shaped arrangement yielding clinically applicable tomographic images even for large objects. (author)

  17. Generalized Row-Action Methods for Tomographic Imaging

    DEFF Research Database (Denmark)

    Andersen, Martin Skovgaard; Hansen, Per Christian

    2014-01-01

    Row-action methods play an important role in tomographic image reconstruction. Many such methods can be viewed as incremental gradient methods for minimizing a sum of a large number of convex functions, and despite their relatively poor global rate of convergence, these methods often exhibit fast...... initial convergence which is desirable in applications where a low-accuracy solution is acceptable. In this paper, we propose relaxed variants of a class of incremental proximal gradient methods, and these variants generalize many existing row-action methods for tomographic imaging. Moreover, they allow...

  18. Tomographs based on non-conventional radiation sources and methods

    International Nuclear Information System (INIS)

    Barbuzza, R.; Fresno, M. del; Venere, Marcelo J.; Clausse, Alejandro; Moreno, C.

    2000-01-01

    Computer techniques for tomographic reconstruction of objects X-rayed with a compact plasma focus (PF) are presented. The implemented reconstruction algorithms are based on stochastic searching of solutions of Radon equation, using Genetic Algorithms and Monte Carlo methods. Numerical experiments using actual projections were performed concluding the feasibility of the application of both methods in tomographic reconstruction problem. (author)

  19. Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: A multicenter trial

    International Nuclear Information System (INIS)

    Van Train, K.F.; Maddahi, J.; Berman, D.S.; Kiat, H.; Areeda, J.; Prigent, F.; Friedman, J.

    1990-01-01

    The accuracy of the previously developed and validated Cedars-Sinai Medical Center (CSMC) computer program for quantitative analysis of thallium-201 ( 201 TI) stress myocardial tomograms was assessed in a multicenter trial consisting of 242 patients with coronary angiography and 76 with a low likelihood (LL) of coronary artery disease (CAD) involving various cameras, computers, and operators. The program utilized gender-matched normal limits developed from 35 LL patients at CSMC. The multicenter results as compared to those of 168 patients from CSMC were not significantly different with respect to the overall sensitivities (94% versus 95%) and specificities (44% versus 56%) for identification of CAD and normalcy rates which were determined in LL patients (82% for both) and with respect to identification of individual diseased arteries. The results indicate that our method for quantifying tomographic 201 TI stress scintigrams utilizing standard normal limits can be applied at other institutions by different operators, using a variety of cameras and computers, with similar accuracy to that currently obtained at our institution

  20. Construction of tomographic head model using sectioned photographic images of cadaver

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Lee, Jai Ki; Park, Jin Seo; Chung, Min Suk

    2004-01-01

    Tomographic models are currently the most complete, developed and realistic models of the human anatomy. They have been used to estimate organ doses for diagnostic radiation examination and radiotherapy treatment planning, and radiation protection. The quality of original anatomic images is a key factor to build a quality tomographic model. Computed tomography (CT) and magnetic resonance imaging (MRI) scan, from which most of current tomographic models are constructed, have their inherent shortcomings. In this study, a tomographic model of Korean adult male head was constructed by using serially sectioned photographs of cadaver. The cadaver was embedded, frozen, serially sectioned and photographed by high resolution digital camera at 0.2 mm interval. The contours of organs and tissues in photographs were segmented by several trained anatomists. The 120 segmented images of head at 2mm interval were converted into binary files and ported into Monte Carlo code to perform an example calculation of organ dose. Whole body tomographic model will be constructed by using the procedure developed in this study

  1. The Use of Statistical Process Control-Charts for Person-Fit Analysis on Computerized Adaptive Testing. LSAC Research Report Series.

    Science.gov (United States)

    Meijer, Rob R.; van Krimpen-Stoop, Edith M. L. A.

    In this study a cumulative-sum (CUSUM) procedure from the theory of Statistical Process Control was modified and applied in the context of person-fit analysis in a computerized adaptive testing (CAT) environment. Six person-fit statistics were proposed using the CUSUM procedure, and three of them could be used to investigate the CAT in online test…

  2. Microcomputer Network for Computerized Adaptive Testing (CAT)

    Science.gov (United States)

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  3. Reproducibility of temporomandibular joint tomography. Influence of shifted X-ray beam and tomographic focal plane on reproducibility

    International Nuclear Information System (INIS)

    Saito, Masashi

    1999-01-01

    Proper tomographic focal plane and x-ray beam direction are the most important factors to obtain accurate images of the temporomandibular joint (TMJ). In this study, to clarify the magnitude of effect of these two factors on the image quality. We evaluated the reproducibility of tomograms by measuring the distortion when the x-ray beam was shifted from the correct center of the object. The effects of the deviation of the tomographic focal plane on image quality were evaluated by the MTF (Modulation Transfer Function). Two types of tomograms, one the plane type, the other the rotational type were used in this study. A TMJ model was made from Teflon for the purpose of evaluation by shifting the x-ray beam. The x-ray images were obtained by tilting the model from 0 to 10 degrees 2-degree increments. These x-ray images were processed for computer image analysis, and then the distance between condyle and the joint space was measured. To evaluate the influence of the shifted tomographic focal plane on image sharpness, the x-ray images from each setting were analyzed by MTF. To obtain the MTF, ''knife-edge'' made from Pb was used. The images were scanned with a microdensitometer at the central focal plane, and 0, 0.5, 1 mm away respectively. The density curves were analyzed by Fourier analysis and the MTF was calculated. The reproducibility of images became worse by shifting the x-ray beam. This tendency was similar for both tomograms. Object characteristics such as anterior and posterior portion of the joint space affected the deterioration of reproducibility of the tomography. The deviation of the tomographic focal plane also decreased the reproducibility of the x-ray images. The rotational type showed a better MTF, but it became seriously unfavorable with slight changes of the tomographic focal plane. Contrarily, the plane type showed a lower MTF, but the image was stable with shifting of the tomographic focal plane. (author)

  4. AUTOMATIC ESTIMATION OF SIZE PARAMETERS USING VERIFIED COMPUTERIZED STEREOANALYSIS

    Directory of Open Access Journals (Sweden)

    Peter R Mouton

    2011-05-01

    Full Text Available State-of-the-art computerized stereology systems combine high-resolution video microscopy and hardwaresoftware integration with stereological methods to assist users in quantifying multidimensional parameters of importance to biomedical research, including volume, surface area, length, number, their variation and spatial distribution. The requirement for constant interactions between a trained, non-expert user and the targeted features of interest currently limits the throughput efficiency of these systems. To address this issue we developed a novel approach for automatic stereological analysis of 2-D images, Verified Computerized Stereoanalysis (VCS. The VCS approach minimizes the need for user interactions with high contrast [high signal-to-noise ratio (S:N] biological objects of interest. Performance testing of the VCS approach confirmed dramatic increases in the efficiency of total object volume (size estimation, without a loss of accuracy or precision compared to conventional computerized stereology. The broad application of high efficiency VCS to high-contrast biological objects on tissue sections could reduce labor costs, enhance hypothesis testing, and accelerate the progress of biomedical research focused on improvements in health and the management of disease.

  5. Computerized analysis of the 12-lead electrocardiogram to identify epicardial ventricular tachycardia exit sites.

    Science.gov (United States)

    Yokokawa, Miki; Jung, Dae Yon; Joseph, Kim K; Hero, Alfred O; Morady, Fred; Bogun, Frank

    2014-11-01

    Twelve-lead electrocardiogram (ECG) criteria for epicardial ventricular tachycardia (VT) origins have been described. In patients with structural heart disease, the ability to predict an epicardial origin based on QRS morphology is limited and has been investigated only for limited regions in the heart. The purpose of this study was to determine whether a computerized algorithm is able to accurately differentiate epicardial vs endocardial origins of ventricular arrhythmias. Endocardial and epicardial pace-mapping were performed in 43 patients at 3277 sites. The 12-lead ECGs were digitized and analyzed using a mixture of gaussian model (MoG) to assess whether the algorithm was able to identify an epicardial vs endocardial origin of the paced rhythm. The MoG computerized algorithm was compared to algorithms published in prior reports. The computerized algorithm correctly differentiated epicardial vs endocardial pacing sites for 80% of the sites compared to an accuracy of 42% to 66% of other described criteria. The accuracy was higher in patients without structural heart disease than in those with structural heart disease (94% vs 80%, P = .0004) and for right bundle branch block (82%) compared to left bundle branch block morphologies (79%, P = .001). Validation studies showed the accuracy for VT exit sites to be 84%. A computerized algorithm was able to accurately differentiate the majority of epicardial vs endocardial pace-mapping sites. The algorithm is not region specific and performed best in patients without structural heart disease and with VTs having a right bundle branch block morphology. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Computerized system for measuring cerebral metabolism

    International Nuclear Information System (INIS)

    McGlone, J.S.; Hibbard, L.S.; Hawkins, R.A.; Kasturi, R.

    1987-01-01

    A computerized stereotactic measurement system for evaluating rat brain metabolism was developed to utilize the large amount of data generated by quantitative autoradiography. Conventional methods of measurement only analyze a small percent of these data because these methods are limited by instrument design and the subjectiveness of the investigator. However, a computerized system allows digital images to be analyzed by placing data at their appropriate three-dimensional stereotactic coordinates. The system automatically registers experimental data to a standard three-dimensional image using alignment, scaling, and matching operations. Metabolic activity in different neuronal structures is then measured by generating digital masks and superimposing them on to experimental data. Several experimental data sets were evaluated and it was noticed that the structures measured by the computerized system, had in general, lower metabolic activity than manual measurements had indicated. This was expected because the computerized system measured the structure over its volume while the manual readings were taken from the most active metabolic area of a particular structure

  7. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    International Nuclear Information System (INIS)

    Lu, W; Wang, J; Zhang, H

    2015-01-01

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that

  8. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lu, W; Wang, J; Zhang, H [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that

  9. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Rogers, J.G.; Atkins, M.S.

    1989-01-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. the data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition system. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events which are 64 bits wide

  10. Linear analysis of rotationally invariant, radially variant tomographic imaging systems

    International Nuclear Information System (INIS)

    Huesmann, R.H.

    1990-01-01

    This paper describes a method to analyze the linear imaging characteristics of rotationally invariant, radially variant tomographic imaging systems using singular value decomposition (SVD). When the projection measurements from such a system are assumed to be samples from independent and identically distributed multi-normal random variables, the best estimate of the emission intensity is given by the unweighted least squares estimator. The noise amplification of this estimator is inversely proportional to the singular values of the normal matrix used to model projection and backprojection. After choosing an acceptable noise amplification, the new method can determine the number of parameters and hence the number of pixels that should be estimated from data acquired from an existing system with a fixed number of angles and projection bins. Conversely, for the design of a new system, the number of angles and projection bins necessary for a given number of pixels and noise amplification can be determined. In general, computing the SVD of the projection normal matrix has cubic computational complexity. However, the projection normal matrix for this class of rotationally invariant, radially variant systems has a block circulant form. A fast parallel algorithm to compute the SVD of this block circulant matrix makes the singular value analysis practical by asymptotically reducing the computation complexity of the method by a multiplicative factor equal to the number of angles squared

  11. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  12. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  13. Computerized reactor monitor and control for research reactors

    International Nuclear Information System (INIS)

    Buerger, L.; Vegh, E.

    1981-09-01

    The computerized process control system developed in the Central Research Institute for Physics, Budapest, Hungary, is described together with its special applications at research reactors. The nuclear power of the Hungarian research reactor is controlled by this computerized system, too, while in Lybia many interesting reactor-hpysical calculations are built into the computerized monitor system. (author)

  14. Construction of a positron emission tomograph with 2.4 mm detectors

    International Nuclear Information System (INIS)

    McIntyre, J.A.; Sprosst, R.L.; Wang, K.

    1986-01-01

    One-quarter of one ring of a positron tomograph has been constructed. The positron annihilation gamma rays are detected by polished plastic scintillators which direct scintillation light by internal reflection to optical fibers for transmission to the photo-multiplier tubes. By viewing each scintillator with four sets of optical fibers, the number of photomultipliers required for an eight ring tomograph with 1024 detectors per ring (2.4 mm wide detectors) can be reduced from 8192 to 288, and the cost of the tomograph reduced accordingly

  15. Expediting model-based optoacoustic reconstructions with tomographic symmetries

    International Nuclear Information System (INIS)

    Lutzweiler, Christian; Deán-Ben, Xosé Luís; Razansky, Daniel

    2014-01-01

    Purpose: Image quantification in optoacoustic tomography implies the use of accurate forward models of excitation, propagation, and detection of optoacoustic signals while inversions with high spatial resolution usually involve very large matrices, leading to unreasonably long computation times. The development of fast and memory efficient model-based approaches represents then an important challenge to advance on the quantitative and dynamic imaging capabilities of tomographic optoacoustic imaging. Methods: Herein, a method for simplification and acceleration of model-based inversions, relying on inherent symmetries present in common tomographic acquisition geometries, has been introduced. The method is showcased for the case of cylindrical symmetries by using polar image discretization of the time-domain optoacoustic forward model combined with efficient storage and inversion strategies. Results: The suggested methodology is shown to render fast and accurate model-based inversions in both numerical simulations andpost mortem small animal experiments. In case of a full-view detection scheme, the memory requirements are reduced by one order of magnitude while high-resolution reconstructions are achieved at video rate. Conclusions: By considering the rotational symmetry present in many tomographic optoacoustic imaging systems, the proposed methodology allows exploiting the advantages of model-based algorithms with feasible computational requirements and fast reconstruction times, so that its convenience and general applicability in optoacoustic imaging systems with tomographic symmetries is anticipated

  16. Quality of computerized blast load simulation for non-linear dynamic ...

    African Journals Online (AJOL)

    Quality of computerized blast load simulation for non-linear dynamic response ... commercial software system and a special-purpose, blast-specific software product to ... depend both on the analysis model of choice and the stand-off distances.

  17. Trends in computerized structural analysis and synthesis; Proceedings of the Symposium, Washington, D.C., October 30-November 1, 1978

    Science.gov (United States)

    Noor, A. K. (Editor); Mccomb, H. G., Jr.

    1978-01-01

    The subjects considered are related to future directions of structural applications and potential of new computing systems, advances and trends in data management and engineering software development, advances in applied mathematics and symbolic computing, computer-aided instruction and interactive computer graphics, nonlinear analysis, dynamic analysis and transient response, structural synthesis, structural analysis and design systems, advanced structural applications, supercomputers, numerical analysis, and trends in software systems. Attention is given to the reliability and optimality of the finite element method, computerized symbolic manipulation in structural mechanics, a standard computer graphics subroutine package, and a drag method as a finite element mesh generation scheme.

  18. Experience of computed tomographic myelography and discography in cervical problem

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, Shigeru; Yamamoto, Masayuki; Uratsuji, Masaaki; Suzuki, Kunio; Matsui, Eigo [Hyogo Prefectural Awaji Hospital, Sumoto, Hyogo (Japan); Kurihara, Akira

    1983-06-01

    CTM (computed tomographic myelography) was performed on 15 cases of cervical lesions, and on 5 of them, CTD (computed tomographic discography) was also made. CTM revealed the intervertebral state, and in combination with CTD, providing more accurate information. The combined method of CTM and CTD was useful for soft disc herniation.

  19. Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.

    Science.gov (United States)

    de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib

    2014-11-25

    Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion

  20. Construction of Korean male tomographic model segmented from PET-CT data

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Park, Sang Kyun; Lee, Jai Ki

    2004-01-01

    Tomographic human models provide currently the most realistic representation of human anatomy for radiation dosimetry calculation. Most of the models have been constructed by using computed tomographic (CT) or magnetic resonance (MR) images obtained from a single individual. Each scan has its inherent advantages and disadvantages. CT scan gives a considerable radiation dose to a subject, and MR scan takes too long time to get clear images of an immobile subject. An emerging source of medical images for the construction of tomographic models is PET-CT, which is performed when looking for cancer. In this study, a tomographic model of Korean adult male was developed by processing whole-body CT images of a PET-CT-scanned healthy volunteer. The 343 slices of the CT images were semi-automatically segmented layer by layer using a graphic software and screen digitizer. The 3rd Korean tomographic model, named KRMAN-2, consisting of 300x150x344 voxels of a size of 2x2x5mm 3 , was constructed. Examples of application to Monte Carlo radiation dosimetry calculation in idealized whole-body irradiations were given and discussed

  1. Study of computerized tomography using neutron beam

    International Nuclear Information System (INIS)

    Pereira, W.W.

    1991-05-01

    This paper aims to demonstrate the advantages, shortcomings and complementaries of a tomography development using neutrons over the one employing gamma rays in the context of their applications to non destructive essays. A simulated experimental study was performed in order to compare the two aforementioned tomographic procedures as applied to some materials. These materials were chosen for their clear advantages and complementaries as, for instance, aluminium, iron, plastic and aluminium hydroxide. In this work two tomographic systems, are employed both with parallel beams. The first with a gamma radiation source (Caesium-137), with an energy of 662 KeV and an activity of 3,9 x 10 9 Bq (100 mCi) and the second one employing a neutron source, the Argonaut Reactor of the Instituto de Engenharia Nuclear, IEN/CNEN, from where the thermal neutron beam of about 10 5 n/(cm.s) was obtained. It is possible to conclude from the simulated and experimental results, by means of image analysis and distortion measurements, that for a given material the adequate radiation and its energy may be chosen so as to better characterize it. (author)

  2. Computerized tomography of the pancreas

    International Nuclear Information System (INIS)

    Dondelinger, R.; Campos, R.O.; Lamarque, J.L.

    1979-01-01

    Pancreatic anatomy is briefly reviewed. Tomographic images from normal pancreas and from pathological states (different kinds of pancreatitis; pancreatic tumors) of this organ are discussed. (M.A.) [pt

  3. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer

    2004-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  4. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer S

    2005-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  5. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  6. Algorithms for Computerized Fetal Heart Rate Diagnosis with Direct Reporting

    Directory of Open Access Journals (Sweden)

    Kazuo Maeda

    2015-06-01

    Full Text Available Aims: Since pattern classification of fetal heart rate (FHR was subjective and enlarged interobserver difference, objective FHR analysis was achieved with computerized FHR diagnosis. Methods: The computer algorithm was composed of an experts’ knowledge system, including FHR analysis and FHR score calculation, and also of an objective artificial neural network system with software. In addition, a FHR frequency spectrum was studied to detect ominous sinusoidal FHR and the loss of baseline variability related to fetal brain damage. The algorithms were installed in a central-computerized automatic FHR monitoring system, which gave the diagnosis rapidly and directly to the attending doctor. Results: Clinically perinatal mortality decreased significantly and no cerebral palsy developed after introduction of the centralized system. Conclusion: The automatic multichannel FHR monitoring system improved the monitoring, increased the objectivity of FHR diagnosis and promoted clinical results.

  7. Algorithms for the Analysis of 3D Magnetic Resonance Angiography Images

    International Nuclear Information System (INIS)

    Tizon, Xavier

    2004-01-01

    Atherosclerosis is a disease of the arterial wall, progressively impairing blood flow as it spreads throughout the body. The heart attacks and strokes that result of this condition cause more deaths than cancer in industrial countries. Angiography refers to the group of imaging techniques used through the diagnosis, treatment planning and follow-up of atherosclerosis. In recent years, Magnetic Resonance Angiography (MRA) has shown promising abilities to supplant conventional, invasive, X-ray-based angiography. In order to fully benefit from this modality, there is a need for more objective and reproducible methods. This thesis shows, in two applications, how computerized image analysis can help define and implement these methods. First, by using segmentation to improve visualization of blood-pool contrast enhanced (CE)-MRA, with an additional application in coronary Computerized Tomographic Angiography. We show that, using a limited amount of user interaction and an algorithmic framework borrowed from graph theory and fuzzy logic theory, we can simplify the display of complex 3D structures like vessels. Second, by proposing a methodology to analyze the geometry of arteries in whole-body CE-MRA. The vessel centreline is extracted, and geometrical properties of this 3D curve are measured, to improve interpretation of the angiograms. It represents a more global approach than the conventional evaluation of atherosclerosis, as a first step towards screening for vascular diseases. We have developed the methods presented in this thesis with clinical practice in mind. However, they have the potential to be useful to other applications of computerized image analysis

  8. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  9. Preparation and tomographic reconstruction of an arbitrary single-photon path qubit

    International Nuclear Information System (INIS)

    Baek, So-Young; Kim, Yoon-Ho

    2011-01-01

    We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. The arbitrary single-photon path qubit is prepared losslessly by passing the heralded single-photon state from spontaneous parametric down-conversion through variable beam splitter. Quantum state tomography of the single-photon path qubit is implemented by introducing path-projection measurements based on the first-order single-photon quantum interference. Using the state preparation and path-projection measurements methods for the single-photon path qubit, we demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity. -- Highlights: → We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. → We implement path-projection measurements based on the first-order single-photon quantum interference. → We demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity.

  10. New techniques for resolution enhancement of 3D x-ray tomographic imaging from incomplete data

    International Nuclear Information System (INIS)

    Vengrinovich, V.; Zolotarev, S.; Denkevich, Y.; Tillack, G.-R.

    2004-01-01

    Accurate evaluation of dimensions directly from tomographic images, restored from only few x-ray projections, made in a limited observation sector, is considered exploiting pipes wall thickness assessment like a typical example. Both experiments and simulations are used to extract main errors sources. It is taken from as known, that neglecting of the scattered radiation and beam hardening effects results in image blurring, strong artifacts and finally inaccurate sizing. The computerized technique is developed to simulate the contribution of scattered radiation and beam hardening for the purpose of their further extraction from projected data. After those accompanying effects extraction the iterative Bayesian techniques are applied to reconstruct images from the projections, using volumetric and/or shell representation of the objects like pipes. The achieved error of virtual pipe wall thickness assessment from 3D images can be as small as 300μk comparing to 1mm provided by modern techniques. Finally the conclusion was drawn that standard projection techniques using X- or Gamma rays in combination with X-ray film or imaging plates can be applied for the data acquisition to reconstruct finally wall thickness profiles in an in-field environment. (author)

  11. Computed tomographic findings of intracranial gliosis

    International Nuclear Information System (INIS)

    Weisberg, L.

    1981-01-01

    The clinical and computed tomographic (CT) findings in eight patients with pathological evidence of cerebral gliosis are analyzed. CT findings do not permit differentiation of gliosis from other neoplastic and non-neoplastic conditions. (orig.)

  12. Preexisting Dentinal Microcracks in Nonendodontically Treated Teeth: An Ex Vivo Micro-computed Tomographic Analysis.

    Science.gov (United States)

    PradeepKumar, Angambakkam Rajasekaran; Shemesh, Hagay; Chang, Jeffrey Wen-Wei; Bhowmik, Ahendita; Sibi, Swamy; Gopikrishna, Velayutham; Lakshmi-Narayanan, Lakshmikanthanbharathi; Kishen, Anil

    2017-06-01

    This study evaluated the prevalence, location, and pattern of preexisting dentinal microcracks in roots of extracted teeth without endodontic treatment in patients from 2 age groups using micro-computed tomographic imaging. Six hundred thirty-three nonendodontically treated teeth extracted using an atraumatic procedure because of reasons unrelated to this study were collected and divided based on the patient age. Teeth were scanned with micro-computed tomographic imaging (resolution of 26.7 μm) to examine the presence of preexisting dentinal microcracks in roots. The characteristic features of preexisting dentinal microcracks determined were location, extent, length, and coronoapical distribution. Chi-square bivariate analysis was performed to assess the association between various parameters. Forty-five of 633 nonendodontically treated teeth exhibited preexisting microcracks in roots with a prevalence of 7.1%. The prevalence of preexisting microcracks was found to be 8.3% in older patients (40-70 years) compared with 3.7% in younger patients (20-39 years) (P < .050). A significant association was found between the preexisting microcracks in mandibular teeth (10.3%) when compared with maxillary teeth (2.9%) (P < .001). All preexisting microcracks were located mesiodistally; 66% occurred in the cervical and middle thirds of root. Only 33% of the preexisting microcracks were complete in nature, showing canal involvement. Complete dentinal microcracks exhibited a mean length of 6.9 mm, whereas incomplete cracks had a mean length of 3.75 mm (P < .001). Preexisting dentinal microcracks in roots of nonendodontically treated teeth occurred more often in older patients (40-70 years) in the mesiodistal direction. They were predominantly found in the cervical and middle thirds of root and were more likely to be incomplete in nature. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Original circuitry for TOHR tomograph

    International Nuclear Information System (INIS)

    Cuzon, J.C.; Pinot, L.

    1999-01-01

    Having industrialization in mind, a specific electronics for a high resolution tomograph is designed out of the usual standards of nuclear physics. All the information are converted in the time domain and a fast processor, in front of the data acquisition, carries out the time and energy coincidences. (authors)

  14. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Atkins, M.S.; Wilkinson, N.A.; Rogers, J.G.

    1988-11-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. The data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition systems. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events per second for raw events which are 64 bits wide. Real-time data acquisition and pre-processing requirements can be met by about forty 20 MHz Motorola 68020/68881 processors

  15. Correction of ring artifacts in X-ray tomographic images

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Johnson, G.; Tafforeau, P.

    2011-01-01

    Ring artifacts are systematic intensity distortions located on concentric circles in reconstructed tomographic X-ray images. When using X-ray tomography to study for instance low-contrast grain boundaries in metals it is crucial to correct for the ring artifacts in the images as they may have...... the same intensity level as the grain boundaries and thus make it impossible to perform grain segmentation. This paper describes an implementation of a method for correcting the ring artifacts in tomographic X-ray images of simple objects such as metal samples where the object and the background...... are separable. The method is implemented in Matlab, it works with very little user interaction and may run in parallel on a cluster if applied to a whole stack of images. The strength and robustness of the method implemented will be demonstrated on three tomographic X-ray data sets: a mono-phase β...

  16. Non-Conventional Applications of Computerized Tomography: Analysis of Solid Dosage Forms Produced by Pharmaceutical Industry

    International Nuclear Information System (INIS)

    Martins de Oliveira, Jose Jr.; Germano Martins, Antonio Cesar

    2010-01-01

    X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques.

  17. Using computerized text analysis to assess communication within an Italian type 1 diabetes Facebook group

    Directory of Open Access Journals (Sweden)

    Alda Troncone

    2015-11-01

    Full Text Available The purpose of this study was to assess messages posted by mothers of children with type 1 diabetes in the Italian Facebook group “Mamme e diabete” using computerized text analysis. The data suggest that these mothers use online discussion boards as a place to seek and provide information to better manage the disease’s daily demands—especially those tasks linked to insulin correction and administration, control of food intake, and bureaucratic duties, as well as to seek and give encouragement and to share experiences regarding diabetes and related impact on their life. The implications of these findings for the management of diabetes are discussed.

  18. Computerized Classification Testing with the Rasch Model

    Science.gov (United States)

    Eggen, Theo J. H. M.

    2011-01-01

    If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…

  19. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    International Nuclear Information System (INIS)

    Xu Song; Song Fei; Li Zhizhong; Zhao Qianyi; Luo Wei; He Xuhong; Salvendy, Gavriel

    2008-01-01

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs

  20. An ergonomics study of computerized emergency operating procedures: Presentation style, task complexity, and training level

    Energy Technology Data Exchange (ETDEWEB)

    Xu Song; Song Fei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li Zhizhong [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)], E-mail: zzli@tsinghua.edu.cn; Zhao Qianyi; Luo Wei [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); He Xuhong [Scanpower Risk Management China Inc., Towercrest International Plaza, No. 3 Maizidian West Road, Chaoyang District, Beijing 100016 (China); Salvendy, Gavriel [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)

    2008-10-15

    Emergency operating procedures (EOPs) are widely used in nuclear power plants (NPPs). With the development of information technology, computerized EOPs are taking the place of paper-based ones. Unlike paper-based EOPs, the industrial practice of computerized EOPs is still quite limited. Ergonomics issues of computerized EOPs have not been studied adequately. This study focuses on the effects of EOP presentation style, task complexity, and training level on the performance of the operators in the execution of computerized EOPs. One simulated computerized EOP system was developed to present two EOPs, each with different task complexity levels, by two presentation styles (Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination). Forty subjects participated in the experiment of EOP execution using the simulated system. Statistical analysis of the experimental results indicates that: (1) complexity, presentation style, and training level all can significantly influence the error rate. High-complexity tasks and lack of sufficient training may lead to a higher error rate. Style B caused a significantly higher error rate than style A did in the skilled phase. So the designers of computerized procedures should take the presentation styles of EOPs into account. (2) Task complexity and training level can significantly influence operation time. No significant difference was found in operation time between the two presentation styles. (3) Training level can also significantly influence the subjective workload of EOPs operations. This implies that adequate training is very important for the performance of computerized EOPs even if emergency responses with computerized EOPs are much more simple and easy than that with paper-based EOPs.

  1. INTEGRATION PECULIARITIES OF COMPUTERIZED MEANS OF EDUCATION INTO THE PROCESS OF TEACHER TRAINING AT PEDAGOGICAL COLLEGES

    Directory of Open Access Journals (Sweden)

    Olga M. Naumenko

    2010-08-01

    Full Text Available Important problems of using the computerized means of education in the process of teacher training at pedagogical college are considered. On the basis of the analysis of the organisation of educational process in different pedagogical colleges, the general principles of construction of the educational module “Methodology of computerized means of education in educational process” are considered.

  2. Computerized nipple identification for multiple image analysis in computer-aided diagnosis

    International Nuclear Information System (INIS)

    Zhou Chuan; Chan Heangping; Paramagul, Chintana; Roubidoux, Marilyn A.; Sahiner, Berkman; Hadjiiski, Labomir M.; Petrick, Nicholas

    2004-01-01

    Correlation of information from multiple-view mammograms (e.g., MLO and CC views, bilateral views, or current and prior mammograms) can improve the performance of breast cancer diagnosis by radiologists or by computer. The nipple is a reliable and stable landmark on mammograms for the registration of multiple mammograms. However, accurate identification of nipple location on mammograms is challenging because of the variations in image quality and in the nipple projections, resulting in some nipples being nearly invisible on the mammograms. In this study, we developed a computerized method to automatically identify the nipple location on digitized mammograms. First, the breast boundary was obtained using a gradient-based boundary tracking algorithm, and then the gray level profiles along the inside and outside of the boundary were identified. A geometric convergence analysis was used to limit the nipple search to a region of the breast boundary. A two-stage nipple detection method was developed to identify the nipple location using the gray level information around the nipple, the geometric characteristics of nipple shapes, and the texture features of glandular tissue or ducts which converge toward the nipple. At the first stage, a rule-based method was designed to identify the nipple location by detecting significant changes of intensity along the gray level profiles inside and outside the breast boundary and the changes in the boundary direction. At the second stage, a texture orientation-field analysis was developed to estimate the nipple location based on the convergence of the texture pattern of glandular tissue or ducts towards the nipple. The nipple location was finally determined from the detected nipple candidates by a rule-based confidence analysis. In this study, 377 and 367 randomly selected digitized mammograms were used for training and testing the nipple detection algorithm, respectively. Two experienced radiologists identified the nipple locations

  3. Tomographic findings of lobar consolidation in primary pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Pereira, Bruno Alberto Falcao; Macedo, Solange Goncalves David de; Penna, Claudia Renata Rezende

    2009-01-01

    Objective: To describe tomographic findings of lobar consolidation as early manifestation of primary pulmonary tuberculosis. Materials and methods: The present study was developed at Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2002 and 2006, retrospectively evaluating tomographic findings in four children aged from 3 to 14 months with lobar consolidation as an early manifestation of primary pulmonary tuberculosis. Results: The most frequently found radiological pattern was lobar consolidation with calcifications, cavitation and intermingle necrotic areas, associated with bulging fissure. Signs of bronchogenic dissemination and lymph node enlargement were observed in all of the four children. Consolidation with a pseudotumor aspect and masslike effect was observed in one case. Conclusion: The cases included in the present study have demonstrated that primary pulmonary tuberculosis manifested as lobar consolidation presents typical tomographic images such as cavitation, hypodense areas and calcifications intermingled with consolidation. The association with lymph node enlargement with central necrosis and signs of bronchogenic dissemination reinforce the diagnosis of tuberculosis. (author)

  4. A computerized glow curve analysis (GCA) method for WinREMS thermoluminescent dosimeter data using MATLAB

    International Nuclear Information System (INIS)

    Harvey, John A.; Rodrigues, Miesher L.; Kearfott, Kimberlee J.

    2011-01-01

    A computerized glow curve analysis (GCA) program for handling of thermoluminescence data originating from WinREMS is presented. The MATLAB program fits the glow peaks using the first-order kinetics model. Tested materials are LiF:Mg,Ti, CaF 2 :Dy, CaF 2 :Tm, CaF 2 :Mn, LiF:Mg,Cu,P, and CaSO 4 :Dy, with most having an average figure of merit (FOM) of 1.3% or less, with CaSO 4 :Dy 2.2% or less. Output is a list of fit parameters, peak areas, and graphs for each fit, evaluating each glow curve in 1.5 s or less. - Highlights: → Robust algorithm for performing thermoluminescent dosimeter glow curve analysis. → Written in MATLAB so readily implemented on variety of computers. → Usage of figure of merit demonstrated for six different materials.

  5. Radiographic and tomographic study of the elbow joint in dogs; Avaliacao morfologica e morfometrica da articulacao umerorradioulnar em caes atraves de exames radiograficos e por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C., E-mail: anacarol@usp.br [Universidade de Sao Paulo (FMVZ/USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia

    2017-02-15

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  6. Analysis of factors influencing the integrated bolus peak timing in contrast-enhanced brain computed tomographic angiography

    International Nuclear Information System (INIS)

    Son, Soon Yong; Choi, Kwan Woo; Jeong, Hoi Woun; Jang, Seo Goo; Jung, Jae Young; Yun, Jung Soo; Kim, Ki Won; Lee, Young Ah; Son, Jin Hyun; Min, Jung Whan

    2016-01-01

    The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast- enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was 716.53 mGy·cm and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination

  7. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    Science.gov (United States)

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.

  8. Tomographic images of cerebral blood flow using a slant hole collimator

    International Nuclear Information System (INIS)

    Wraight, E.P.; Barber, R.W.; Crossland, P.; Maltby, P.

    1983-01-01

    The feasibility of using a rotating slant hole (RSH) collimator on simple tomographic equipment such as a standard gamma camera interfaced to a general purpose Nuclear Medicine computer is reported for producing images of cerebral blood flow following the administration of 123 I-iodoamphetamine to patients. Initial studies produced satisfactory images, thus opening the possibility of tomographic cerebral blood flow imaging to centres not possessing sophisticated tomographic equipment. Planar resolution is superior to that reported for a 25 0 RSH collimator. Axial resolution is not as good at small source distances but is comparable at distances beyond 10 cm. Sensitivity is comparable to other RSH collimators and is similar to Technicare's parallel hole general all purpose collimator. (UK)

  9. Present state and development of positron tomographs

    International Nuclear Information System (INIS)

    Allemand, R.; Gariod, R.; Laval, M.; Tournier, F.

    1979-01-01

    This document presents the main characteristics of positron tomographs and analyses the relative importance of the parameters to be taken into consideration in the design of a tomograph: on the one hand, the physical parameters linked to the measurement of the annihilation photons by time coincidence and, on the other, the geometrical and technological parameters of prime importance in minimizing the many spurious effects. The last part endeavours to show this sort of instrumentation has evolved. Using the results obtained in our laboratory by mathematical simulation, the expected advantages are presented on the picture quality of the time of flight measurement of annihilation photons. Where the physical aspects of this method are concerned, the advantage of using cesium fluoride as scintillator is demonstrated [fr

  10. The bar coil for NMR tomograph

    International Nuclear Information System (INIS)

    Bogorodzki, P.; Piatkowski, A.; Wasielewski, J.

    1995-01-01

    The bar coil (bi-planar) for the NMR tomograph, designed for medical diagnostics, has been described. The tests of coil shown that it generates good homogenous magnetic field in a big volume what results in improving of the signal-to-noise ratio

  11. Computerized tomography in orthopaedics and traumatology

    International Nuclear Information System (INIS)

    Boettger, E.; Heckl, R.; Rehabilitations-Krankenhaus Langensteinbach, Karlsbad

    1981-01-01

    Computerized tomography in traumatology is the selected method for the indications mentioned, so that angiographic investigations are only necessary in exceptional cases. Computerized tomography is also better than other methods when diagnozing soft part tumours, however, angiography is still indicated preoperatively for individual cases. CT is only good as additional help to conventional diagnostics with bone tumours. The differential diagnosis cysts-tumour is possible using contrast medium injections. The frequently large soft part share of tumours is recognizable with osteolytic tumours so that a better irradiation and operation planning can be effected. Diseases in the spinal canal can only be assessed with reservation using modern equipment. Lumbar dislocations of the disk can mostly not be sufficiently determined. Perivertebral abscesses can be certainly detected using computerized tomography. This is particularly so for abscesses prior to calcification. (orig.) [de

  12. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, I., E-mail: isabelle.abraham@cea.fr [CEA Ile de France (France); Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr [Université d’Orléans, UFR Sciences, MAPMO, UMR 7349 (France); Carlier, G., E-mail: carlier@ceremade.dauphine.fr [CEREMADE, UMR CNRS 7534, Université Paris IX Dauphine, Pl. de Lattre de Tassigny (France)

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  13. Reconstruction of tomographic image from x-ray projections of a few views

    International Nuclear Information System (INIS)

    Kobayashi, Fujio; Yamaguchi, Shoichiro

    1982-01-01

    Computer tomographs have progressed rapidly, and in the latest high performance types, the photographing time has been shortened to less than 5 sec, but the clear images of hearts have not yet been obtained. The X-ray tomographs used so far irradiate X-ray from many directions and measure the projected data, but by limiting projection direction to a small number, it was planned to shorter the X-ray photographing time and to reduce X-ray exposure as the objective of this study. In this paper, a method is proposed, by which tomographic images are reconstructed from projected data in a small number of direction by generalized inverse matrix penalty method. This method is the calculation method newly devised by the authors for this purpose. It is a kind of the nonlinear planning method added with the restrictive condition using a generalized inverse matrix, and it is characterized by the simple calculation procedure and rapid convergence. Moreover, the effect on reconstructed images when errors are included in projected data was examined. Also, the simple computer simulation to reconstruct tomographic images using the projected data in four directions was performed, and the usefulness of this method was confirmed. It contributes to the development of superhigh speed tomographs in future. (Kako, I.)

  14. Influence of step complexity and presentation style on step performance of computerized emergency operating procedures

    Energy Technology Data Exchange (ETDEWEB)

    Xu Song [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China); Li Zhizhong [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)], E-mail: zzli@tsinghua.edu.cn; Song Fei; Luo Wei; Zhao Qianyi; Salvendy, Gavriel [Department of Industrial Engineering, Tsinghua University, Beijing 100084 (China)

    2009-02-15

    With the development of information technology, computerized emergency operating procedures (EOPs) are taking the place of paper-based ones. However, ergonomics issues of computerized EOPs have not been studied adequately since the industrial practice is quite limited yet. This study examined the influence of step complexity and presentation style of EOPs on step performance. A simulated computerized EOP system was developed in two presentation styles: Style A: one- and two-dimensional flowcharts combination; Style B: two-dimensional flowchart and success logic tree combination. Step complexity was quantified by a complexity measure model based on an entropy concept. Forty subjects participated in the experiment of EOP execution using the simulated system. The results of data analysis on the experiment data indicate that step complexity and presentation style could significantly influence step performance (both step error rate and operation time). Regression models were also developed. The regression analysis results imply that operation time of a step could be well predicted by step complexity while step error rate could only partly predicted by it. The result of a questionnaire investigation implies that step error rate was influenced not only by the operation task itself but also by other human factors. These findings may be useful for the design and assessment of computerized EOPs.

  15. Experimental and theoretical analysis for improved microscope design of optical projection tomographic microscopy.

    Science.gov (United States)

    Coe, Ryan L; Seibel, Eric J

    2013-09-01

    We present theoretical and experimental results of axial displacement of objects relative to a fixed condenser focal plane (FP) in optical projection tomographic microscopy (OPTM). OPTM produces three-dimensional, reconstructed images of single cells from two-dimensional projections. The cell rotates in a microcapillary to acquire projections from different perspectives where the objective FP is scanned through the cell while the condenser FP remains fixed at the center of the microcapillary. This work uses a combination of experimental and theoretical methods to improve the OPTM instrument design.

  16. Effect of gender on computerized electrocardiogram measurements in college athletes.

    Science.gov (United States)

    Mandic, Sandra; Fonda, Holly; Dewey, Frederick; Le, Vy-van; Stein, Ricardo; Wheeler, Matt; Ashley, Euan A; Myers, Jonathan; Froelicher, Victor F

    2010-06-01

    Broad criteria for classifying an electrocardiogram (ECG) as abnormal and requiring additional testing prior to participating in competitive athletics have been recommended for the preparticipation examination (PPE) of athletes. Because these criteria have not considered gender differences, we examined the effect of gender on the computerized ECG measurements obtained on Stanford student athletes. Currently available computer programs require a basis for "normal" in athletes of both genders to provide reliable interpretation. During the 2007 PPE, computerized ECGs were recorded and analyzed on 658 athletes (54% male; mean age, 19 +/- 1 years) representing 22 sports. Electrocardiogram measurements included intervals and durations in all 12 leads to calculate 12-lead voltage sums, QRS amplitude and QRS area, spatial vector length (SVL), and the sum of the R wave in V5 and S wave in V2 (RSsum). By computer analysis, male athletes had significantly greater QRS duration, PR interval, Q-wave duration, J-point amplitude, and T-wave amplitude, and shorter QTc interval compared with female athletes (all P < 0.05). All ECG indicators of left ventricular electrical activity were significantly greater in males. Although gender was consistently associated with indices of atrial and ventricular electrical activity in multivariable analysis, ECG measurements correlated poorly with body dimensions. Significant gender differences exist in ECG measurements of college athletes that are not explained by differences in body size. Our tables of "normal" computerized gender-specific measurements can facilitate the development of automated ECG interpretation for screening young athletes.

  17. Tomographic ventricular reconstruction using multiple view first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lacy, J.L.; Ball, M.E.; Verani, M.S.; Wiles, H.; Roberts, R.

    1985-01-01

    In first-pass radionuclide angiography (FPRA) images of both left and right ventricles are uncontaminated by adjacent structures. Thus, the problem of tomographic reconstruction is vastly simplified compared to equilibrium blood pool imaging in which all structures are imaged simultaneously. Tomographic reconstruction from a limited number of views may thus be possible. A simple filtered interpolative back-projection reconstruction technique was employed. In this technique interpolation was used between sectional distributions at successive angles. Interpolations yielding 9 and 13 back projection angles of 22.5 0 and 15 0 were evaluated. Ventricular borders were obtained in each back-projected tomographic slice by location of the intensity level which provided correct total ventricular volume. Cast cross sections were quantitatively well represented by these borders. This ventricular border definition algorithm forms the basis for applications of the technique in animals and humans

  18. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  19. Image interface in Java for tomographic reconstruction in nuclear medicine

    International Nuclear Information System (INIS)

    Andrade, M.A.; Silva, A.M. Marques da

    2004-01-01

    The aim of this study is to implement a software for tomographic reconstruction of SPECT data from Nuclear Medicine with a flexible interface design, cross-platform, written in Java. Validation tests were performed based on SPECT simulated data. The results showed that the implemented algorithms and filters agree with the theoretical context. We intend to extend the system by implementing additional tomographic reconstruction techniques and Java threads, in order to provide simultaneously image processing. (author)

  20. Pressure spectra from single-snapshot tomographic PIV

    Science.gov (United States)

    Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio

    2018-03-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV

  1. Computerized training program usage at the Fort Calhoun Nuclear Power Station

    International Nuclear Information System (INIS)

    Ruzic, D.H.; Reed, W.H.; Lawton, R.K.; Fluehr, J.J.

    1987-01-01

    The increased US Nuclear Regulatory Commission and Institute of Nuclear Power Operations (INPO) interest in the nuclear power industry training programs resulted in the Omaha Public Power District staff at the Fort Calhoun Nuclear Power Station investigating the potential for computerizing their recently accredited training records, student training requirements, and the process of determining student certification status. Additional areas that were desirable were a computerized question data bank with random test generation, maintaining history of question usage, and tracking of the job task analysis process and course objectives. SCI Software's online personnel training information management system (OPTIM) was selected, subsequent to a bid evaluation, to provide these features while operating on the existing corporate IBM mainframe

  2. Influence of laser power on atom probe tomographic analysis of boron distribution in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Tu, Y., E-mail: ytu@imr.tohoku.ac.jp [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Takamizawa, H.; Han, B.; Shimizu, Y.; Inoue, K.; Toyama, T. [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Yano, F. [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Tokyo City University, Setagaya, Tokyo 158-8557 (Japan); Nishida, A. [Renesas Electronics Corporation, Hitachinaka, Ibaraki 312-8504 (Japan); Nagai, Y. [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan)

    2017-02-15

    The relationship between the laser power and the three-dimensional distribution of boron (B) in silicon (Si) measured by laser-assisted atom probe tomography (APT) is investigated. The ultraviolet laser employed in this study has a fixed wavelength of 355 nm. The measured distributions are almost uniform and homogeneous when using low laser power, while clear B accumulation at the low-index pole of single-crystalline Si and segregation along the grain boundaries in polycrystalline Si are observed when using high laser power (100 pJ). These effects are thought to be caused by the surface migration of atoms, which is promoted by high laser power. Therefore, for ensuring a high-fidelity APT measurement of the B distribution in Si, high laser power is not recommended. - Highlights: • Influence of laser power on atom probe tomographic analysis of B distribution in Si is investigated. • When using high laser power, inhomogeneous distributions of B in single-crystalline and polycrystalline Si are observed. • Laser promoted migration of B atoms over the specimen is proposed to explain these effects.

  3. Decomposition of time-resolved tomographic PIV

    NARCIS (Netherlands)

    Schmid, P.J.; Violato, D.; Scarano, F.

    2012-01-01

    An experimental study has been conducted on a transitional water jet at a Reynolds number of Re = 5,000. Flow fields have been obtained by means of time-resolved tomographic particle image velocimetry capturing all relevant spatial and temporal scales. The measured threedimensional flow fields have

  4. Connections model for tomographic images reconstruction

    International Nuclear Information System (INIS)

    Rodrigues, R.G.S.; Pela, C.A.; Roque, S.F. A.C.

    1998-01-01

    This paper shows an artificial neural network with an adequately topology for tomographic image reconstruction. The associated error function is derived and the learning algorithm is make. The simulated results are presented and demonstrate the existence of a generalized solution for nets with linear activation function. (Author)

  5. HFSB-seeding for large-scale tomographic PIV in wind tunnels

    Science.gov (United States)

    Caridi, Giuseppe Carlo Alp; Ragni, Daniele; Sciacchitano, Andrea; Scarano, Fulvio

    2016-12-01

    A new system for large-scale tomographic particle image velocimetry in low-speed wind tunnels is presented. The system relies upon the use of sub-millimetre helium-filled soap bubbles as flow tracers, which scatter light with intensity several orders of magnitude higher than micron-sized droplets. With respect to a single bubble generator, the system increases the rate of bubbles emission by means of transient accumulation and rapid release. The governing parameters of the system are identified and discussed, namely the bubbles production rate, the accumulation and release times, the size of the bubble injector and its location with respect to the wind tunnel contraction. The relations between the above parameters, the resulting spatial concentration of tracers and measurement of dynamic spatial range are obtained and discussed. Large-scale experiments are carried out in a large low-speed wind tunnel with 2.85 × 2.85 m2 test section, where a vertical axis wind turbine of 1 m diameter is operated. Time-resolved tomographic PIV measurements are taken over a measurement volume of 40 × 20 × 15 cm3, allowing the quantitative analysis of the tip-vortex structure and dynamical evolution.

  6. Tomographic methods in nuclear medicine

    International Nuclear Information System (INIS)

    Ahluwalia, B.D.

    1989-01-01

    This book is a review of the various approaches to tomographic imaging that have been pursued in nuclear medicine. The evolution of single photon emission computed tomography (SPECT) is discussed in detail, and the major classes of instrumentation are represented. A section on positron emission tomography is also included, but is rather brief and may serve only as a general introduction

  7. Mesooptical microscope as a tomographical device

    International Nuclear Information System (INIS)

    Soroko, L.M.

    1989-01-01

    It is shown that there are at least four regions which are common for the mesooptical microscopes, on the one hand, and for the reconstructed tomography, on the other hand. The following characteristics of the mesooptical microscope show the tomographical properties: the structure of the output data concerning the orientation and the position in space of the straight-line objects going at small angles with the perpendicular to the given tomographic plane, the behaviour of the two-dimensional fourier-transform of the straight-line object in the course of the rotation of this object with respect to the specified axis in space, the scanning algorithm of the nuclear emulsion volume by the fence-like illuminated region in the mesooptical microscope for searching for particle tracks going parallel to the optical axis of the microscope, and, finally, the fact that the mesooptical images of the straight-line particle tracks with a common vertex in the nuclear emulsion lie on the sinogram. 12 refs.; 16 figs

  8. Computerized structural mechanics for 1990's: Advanced aircraft needs

    Science.gov (United States)

    Viswanathan, A. V.; Backman, B. F.

    1989-01-01

    The needs for computerized structural mechanics (CSM) as seen from the standpoint of the aircraft industry are discussed. These needs are projected into the 1990's with special focus on the new advanced materials. Preliminary design/analysis, research, and detail design/analysis are identified as major areas. The role of local/global analyses in these different areas is discussed. The lessons learned in the past are used as a basis for the design of a CSM framework that could modify and consolidate existing technology and include future developments in a rational and useful way. A philosophy is stated, and a set of analyses needs driven by the emerging advanced composites is enumerated. The roles of NASA, the universities, and the industry are identified. Finally, a set of rational research targets is recommended based on both the new types of computers and the increased complexity the industry faces. Computerized structural mechanics should be more than new methods in structural mechanics and numerical analyses. It should be a set of engineering applications software products that combines innovations in structural mechanics, numerical analysis, data processing, search and display features, and recent hardware advances and is organized in a framework that directly supports the design process.

  9. Computerized tomographic visualization of niveau by turning the head in a case of pituitary apoplexy

    International Nuclear Information System (INIS)

    Sasajima, Toshio; Mineura, Katsuyoshi; Kowada, Masayoshi; Sasaki, Junko; Sasajima, Hiroyasu; Sakamoto, Tetsuya

    1987-01-01

    A case of pituitary apoplexy is presented in which a free niveau formation, a pathognomonic sign of this entity, was proved by means of computerized tomography (CT) by turning the head. A 48-year-old female had developed a sudden, excruciating, retroorbital headache, vomiting, and visual disturbance twice prior to admission. The visual acuity was 0.1 in the right eye and 0.6 in the left eye. The optic fundi were normal. There was a right temporal field loss and a left upper temporal quadrantanopsia. A plain skull film disclosed ballooning and a double floor of the turcic sella. A CT scan of the head, performed by means of a GE CT/T 8800 Scanner, showed an intrasellar low-density mass with a slightly enhanced rim. We were not convinced of the presence of a high-density area, though there seemed to be one adjacent to the posterior clinoid process and the turcic floor, because of the partial volume effect and the artifact related to the neighboring bones. Another high-resolution CT scan on the ensuing day, as the head was turned and then kept still at about 45 degrees to the right, while the patient was supine, for ten minutes, made it possible to visualize a free fluid level, comparable to a fluid-blood-density level. A transsphenoidal pituitary exploration identified blood fluid collection in the encapsulated tumor, a finding which was histologically consistent with the sinusoidal type of chromophobe adenoma. There was some microscopic evidence of necrosis and hemosiderin laden cells. The postoperative course was uneventful; visual acuity improved without delay, and the temporal field defect became significantly smaller. Two weeks later, visual acuity had recovered to 1.2 uncorrected in each eye. CT and the pertinent position of the head might be quite helpful for the visualization and confirmation of a subtle free fluid level in cases of pituitary apoplexy. (author)

  10. Research on accounting transition from computerization to informationization

    Directory of Open Access Journals (Sweden)

    Shu Chen

    2017-11-01

    Full Text Available The application for computer technology, digitalization technology and network technology in the accounting field has promoted the development of accounting informationization. Accounting informationization is a product integrated with traditional accounting theory and modern information technology, which is an inevitable trend of continuous development of modern accounting. This paper discusses the basic concepts and characteristics of accounting computerization and informationization based on the normative research method and literature data method, analyzes the feasibility of accounting transition from computerization to informationization, and finally puts forward the specific approaches and ultimate goals of accounting transition from computerization to informationization.

  11. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel .E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da; Melo, Pedro Lopes de

    2007-01-01

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  12. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences].E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto University Hospital. Dept. of Radiology and Diagnostic Imaging; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2007-11-15

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  13. Cranial computerized tomography in children suffering from acute leukemia

    International Nuclear Information System (INIS)

    Metz, O.

    1981-01-01

    Cranial computerized (axial) tomography permits a more complete neurologic supervision of children with acute leukemia and a better knowledge of the frequency and varieties of cerebral complications in leukemia. Endocranial complications in acute leukemia are essentially infiltrative, hemorrhagic, infectious or iatrogenic. Cranial computerized tomography can demonstrate cerebral changes in meningeal leukemia, hemorrhages, calcifications, brain atrophy or leukencephalopathy. The preliminary results of cranial computerized tomography in childhood leukemia suggest that the iatrogenic main lesion of the brain due to combined radiation-chemotherapy is atrophy whereas that of the intrathecal cytostatic therapy is demyelination. Accurate diagnostics and control of possible cerebral complications in therapy of leukemia is essentially for appropriate therapeutic management. For that cranial computerized tomography is the best method to a effective supervision of the brain. (author)

  14. COST ANALYSIS OF ALTERNATIVE COMPUTERIZED SYSTEMS FOR THE MARKETING AND DISTRIBUTION OF MULTIPLE FOOD COMMODITIES

    OpenAIRE

    Epperson, James E.; Helmreich, D.P.; Moon, Leonard C.; Carley, Dale H.; Huang, Chung L.; Fletcher, Stanley M.

    1981-01-01

    The authors make cost comparisons among alternative computerized marketing systems. The systems described could encompass any number of commodities and stages of distribution involving cash and/or futures transactions.

  15. Computed-tomographic determination of mineral content of bones

    International Nuclear Information System (INIS)

    Delov, I.; Tabakov, S.

    1988-01-01

    The problem of precise computed-tomographic densitometry of the mineral content of bones is pointed out. A method is proposed including the use of standard density and observance of definite radiation, scanning and image estimation parameters. A good correlation of the results obtained for the mineral content of the lumbar vertebrae with literature data are reported. A method is also described for determining the mineral content of tubular bones based on densiprofile check-up of the computed-tomographic density. The procedure takes 10-15 minutes and includes 1 or 2 scans. It might therefore gain wide acceptance for the diagnosis and tracing of osteoporosis and other osteopathies associated with distrorted calcium metabolism

  16. Regional cerebral blood flow during rest and skilled hand movements by xenon-133 inhalation and emission computerized tomography

    International Nuclear Information System (INIS)

    Lauritzen, M.; Henriksen, L.; Lassen, N.A.

    1981-01-01

    Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating (''dynamic''), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1-min period at a concentration of 10 mCi/L. The arrival and washout of the radioisotope was recorded during four 1-min periods. Two slices, 2 cm thick, 7 and 12 cm above the orbitomeatal line were obtained in every study. CBF averaged 60 ml/100 g/min (SD +/- 11) in the lower slice and 51 ml/100 g/min (SD +/- 13) in the upper slice. A symmetric pattern comparing right to left sides was found in both slices. Finger tapping and writing with the right hand increased CBF in specific areas of the upper slice: in the contralateral hand area by 35 +/- 15% (p less than 0.025), and in the supplementary motor area on both sides by 34 +/- 15%

  17. Chronic subdural hematoma fluid and its computerized tomographic density

    International Nuclear Information System (INIS)

    Masuzawa, Hideaki; Sato, Jinichi; Kamitani, Hiroshi; Yamashita, Midori

    1983-01-01

    Laboratory and in vivo CT analysis were performed on 19 chronic subdural hematomas and five subdural hygromas. In these 25 hematoma samples, red blood cells (RBC), hematocrit, and hemoglobin (Hgb) varied greatly, though, these values correlated well with the CT densities. Plasma protein content was fairly constant with an average of 7.1+-0.8g/dl. There were four hematoma samples with RBC of less than 20x10 4 μl or Hgb of less than 2.0g/dl. Their CT values ranged between 18 and 23 H.U., which were considered close to the in vivo serum level CT density. Five hygroma fluid showed no RBC and very little protein content of less than 0.4g/dl. CT density ranged between -2 and 13 H.U. The edge effect of the skull was experimentally studied using a phantom skull filled with water. This revealed a remarkable overshoot of the CT values within ten pixels from the inner wall of the skull. Visual observation of the original CT pictures revealed four low density hematomas and seven mixed density ones. When compared to the density of the ventricular cavity, all of the low density hematomas and the supernatant part of the mixed density ones were clearly higher in density. All five hygromas appeared CSF dense or lower. In conclusion, because of the edge effect by the skull, thin subdural fluids could not be diagnosed by CT alone. Thick subdural fluids could be differentiated as either hematoma or hygroma by their CT densities. Subdural hematomas had in vivo CT densities of at least serum level or approximately 20 H.U., while subdural hygromas had densities close to CSF. These characteristics were best appreciated by visual observation of the CT scan films. (J.P.N.)

  18. Computerized summary scoring: crowdsourcing-based latent semantic analysis.

    Science.gov (United States)

    Li, Haiying; Cai, Zhiqiang; Graesser, Arthur C

    2017-11-03

    In this study we developed and evaluated a crowdsourcing-based latent semantic analysis (LSA) approach to computerized summary scoring (CSS). LSA is a frequently used mathematical component in CSS, where LSA similarity represents the extent to which the to-be-graded target summary is similar to a model summary or a set of exemplar summaries. Researchers have proposed different formulations of the model summary in previous studies, such as pregraded summaries, expert-generated summaries, or source texts. The former two methods, however, require substantial human time, effort, and costs in order to either grade or generate summaries. Using source texts does not require human effort, but it also does not predict human summary scores well. With human summary scores as the gold standard, in this study we evaluated the crowdsourcing LSA method by comparing it with seven other LSA methods that used sets of summaries from different sources (either experts or crowdsourced) of differing quality, along with source texts. Results showed that crowdsourcing LSA predicted human summary scores as well as expert-good and crowdsourcing-good summaries, and better than the other methods. A series of analyses with different numbers of crowdsourcing summaries demonstrated that the number (from 10 to 100) did not significantly affect performance. These findings imply that crowdsourcing LSA is a promising approach to CSS, because it saves human effort in generating the model summary while still yielding comparable performance. This approach to small-scale CSS provides a practical solution for instructors in courses, and also advances research on automated assessments in which student responses are expected to semantically converge on subject matter content.

  19. Computerized adaptive testing--ready for ambulatory monitoring?

    DEFF Research Database (Denmark)

    Rose, Matthias; Bjørner, Jakob; Fischer, Felix

    2012-01-01

    Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted.......Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted....

  20. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    Science.gov (United States)

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  1. Computerized content analysis of some adolescent writings of Napoleon Bonaparte: a test of the validity of the method.

    Science.gov (United States)

    Gottschalk, Louis A; DeFrancisco, Don; Bechtel, Robert J

    2002-08-01

    The aim of this study was to test the validity of a computer software program previously demonstrated to be capable of making DSM-IV neuropsychiatric diagnoses from the content analysis of speech or verbal texts. In this report, the computer program was applied to three personal writings of Napoleon Bonaparte when he was 12 to 16 years of age. The accuracy of the neuropsychiatric evaluations derived from the computerized content analysis of these writings of Napoleon was independently corroborated by two biographers who have described pertinent details concerning his life situations, moods, and other emotional reactions during this adolescent period of his life. The relevance of this type of computer technology to psychohistorical research and clinical psychiatry is suggested.

  2. Computerized data base of the fundamental constants of nature

    International Nuclear Information System (INIS)

    Henry, E.A.; Hampel, V.E.

    1975-01-01

    Fifty-seven fundamental constants of nature were computerized from the up-to-date evaluations of E. R. Cohen and B. N. Taylor. The constants are annotated with regard to symbol, value, uncertainty, and scaling factor. This computerization is part of the scientific data base project of the Information Research Group at Lawrence Livermore Laboratory. The MASTER CONTROL data base management system is used. The computerized fundamental constants can be requested from the ERDA Computer Program Exchange and Information Center of the Argonne National Laboratory or from the National Technical Information Service of the U. S. Department of Commerce. This is the first of a series of releases on preparation of computerized scientific and technological data banks. The next release is a data bank of conversion factors for different units of measurements. 3 figures

  3. Registration of synthetic tomographic projection data sets using cross-correlation

    International Nuclear Information System (INIS)

    Fitchard, E.E.; Aldridge, J.S.; Reckwerdt, P.J.; Mackie, T.R.

    1998-01-01

    Tomographic registration, a method that makes possible accurate patient registration directly from projection data, consists of three processing steps: (i) manual coarse positioning, (ii) tomographic projection set acquisition, and (iii) computer mediated refined positioning. In the coarse positioning stage, the degree of patient alignment is comparable with that achieved with the standard radiotherapy set-up. However, the accuracy requirements are somewhat more relaxed in that meticulous alignment of the patient using external laser indicators is not necessary. Instead, tomographic projection sets are compared with planning CTs in order to achieve improved patient set-up. The projection sets are cross-correlated to obtain the best-fit translation and rotation offsets. The algorithm has been tested on synthetic data with the incorporation of varying amounts of Gaussian pseudo-random noise. These tests demonstrate the algorithm's stability and also confirm that alignment can be achieved with an accuracy of less than one projection pixel. (author)

  4. Remote diagnosis via a telecommunication satellite--ultrasonic tomographic image transmission experiments.

    Science.gov (United States)

    Nakajima, I; Inokuchi, S; Tajima, T; Takahashi, T

    1985-04-01

    An experiment to transmit ultrasonic tomographic section images required for remote medical diagnosis and care was conducted using the mobile telecommunication satellite OSCAR-10. The images received showed the intestinal condition of a patient incapable of verbal communication, however the image screen had a fairly coarse particle structure. On the basis of these experiments, were considered as the transmission of ultrasonic tomographic images extremely effective in remote diagnosis.

  5. Computerized Modeling and Loaded Tooth Contact Analysis of Hypoid Gears Manufactured by Face Hobbing Process

    Science.gov (United States)

    Nishino, Takayuki

    The face hobbing process has been widely applied in automotive industry. But so far few analytical tools have been developed. This makes it difficult for us to optimize gear design. To settle this situation, this study aims at developing a computerized tool to predict the running performances such as loaded tooth contact pattern, static transmission error and so on. First, based upon kinematical analysis of a cutting machine, a mathematical description of tooth surface generation is given. Second, based upon the theory of gearing and differential geometry, conjugate tooth surfaces are studied. Then contact lines are generated. Third, load distribution along contact lines is formulated. Last, the numerical model is validated by measuring loaded transmission error and loaded tooth contact pattern.

  6. A Multisite, Randomized Controlled Clinical Trial of Computerized Cognitive Remediation Therapy for Schizophrenia.

    Science.gov (United States)

    Gomar, Jesús J; Valls, Elia; Radua, Joaquim; Mareca, Celia; Tristany, Josep; del Olmo, Francisco; Rebolleda-Gil, Carlos; Jañez-Álvarez, María; de Álvaro, Francisco J; Ovejero, María R; Llorente, Ana; Teixidó, Cristina; Donaire, Ana M; García-Laredo, Eduardo; Lazcanoiturburu, Andrea; Granell, Luis; Mozo, Cristina de Pablo; Pérez-Hernández, Mónica; Moreno-Alcázar, Ana; Pomarol-Clotet, Edith; McKenna, Peter J

    2015-11-01

    The effectiveness of cognitive remediation therapy (CRT) for the neuropsychological deficits seen in schizophrenia is supported by meta-analysis. However, a recent methodologically rigorous trial had negative findings. In this study, 130 chronic schizophrenic patients were randomly assigned to computerized CRT, an active computerized control condition (CC) or treatment as usual (TAU). Primary outcome measures were 2 ecologically valid batteries of executive function and memory, rated under blind conditions; other executive and memory tests and a measure of overall cognitive function were also employed. Carer ratings of executive and memory failures in daily life were obtained before and after treatment. Computerized CRT was found to produce improvement on the training tasks, but this did not transfer to gains on the primary outcome measures and most other neuropsychological tests in comparison to either CC or TAU conditions. Nor did the intervention result in benefits on carer ratings of daily life cognitive failures. According to this study, computerized CRT is not effective in schizophrenia. The use of both active and passive CCs suggests that nature of the control group is not an important factor influencing results. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.

  7. Lung cancer, analysis of the most frequent tomographic findings and histopathological correlation, in patients with primary pulmonary neoplasia diagnosed during the years 2011 and 2012, at the Hospital San Juan de Dios

    International Nuclear Information System (INIS)

    Cruz Romero, Cinthia

    2013-01-01

    Tomographic images, specifically the contrasted chest tomographies, were examined in patients diagnosed in patients diagnosed with lung cancer at the Hospital San Juan de Dios during the years 2011 and 2012. The primitive tomographic behavior of lung cancer was evaluated in order to determine and characterize its presentation pattern. Each histological type of lung cancer was determined. The stage of lung cancer was classified according to the International System of Staging Tumor, Node and Metastasis. An analysis of the incidence and stage of lung cancer at the time of diagnosis was made, evidencing the fundamental role of chest tomography in the screening, diagnosis, management and control of patients with primary pulmonary neoplasia [es

  8. Dense velocity reconstruction from tomographic PTV with material derivatives

    Science.gov (United States)

    Schneiders, Jan F. G.; Scarano, Fulvio

    2016-09-01

    A method is proposed to reconstruct the instantaneous velocity field from time-resolved volumetric particle tracking velocimetry (PTV, e.g., 3D-PTV, tomographic PTV and Shake-the-Box), employing both the instantaneous velocity and the velocity material derivative of the sparse tracer particles. The constraint to the measured temporal derivative of the PTV particle tracks improves the consistency of the reconstructed velocity field. The method is christened as pouring time into space, as it leverages temporal information to increase the spatial resolution of volumetric PTV measurements. This approach becomes relevant in cases where the spatial resolution is limited by the seeding concentration. The method solves an optimization problem to find the vorticity and velocity fields that minimize a cost function, which includes next to instantaneous velocity, also the velocity material derivative. The velocity and its material derivative are related through the vorticity transport equation, and the cost function is minimized using the limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. The procedure is assessed numerically with a simulated PTV experiment in a turbulent boundary layer from a direct numerical simulation (DNS). The experimental validation considers a tomographic particle image velocimetry (PIV) experiment in a similar turbulent boundary layer and the additional case of a jet flow. The proposed technique (`vortex-in-cell plus', VIC+) is compared to tomographic PIV analysis (3D iterative cross-correlation), PTV interpolation methods (linear and adaptive Gaussian windowing) and to vortex-in-cell (VIC) interpolation without the material derivative. A visible increase in resolved details in the turbulent structures is obtained with the VIC+ approach, both in numerical simulations and experiments. This results in a more accurate determination of the turbulent stresses distribution in turbulent boundary layer investigations. Data from a jet

  9. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  10. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  11. 3D velocity measurements in a premixed flame by tomographic PIV

    International Nuclear Information System (INIS)

    Tokarev, M P; Sharaborin, D K; Lobasov, A S; Chikishev, L M; Dulin, V M; Markovich, D M

    2015-01-01

    Tomographic particle image velocimetry (PIV) has become a standard tool for 3D velocity measurements in non-reacting flows. However, the majority of the measurements in flows with combustion are limited to small resolved depth compared to the size of the field of view (typically 1 : 10). The limitations are associated with inhomogeneity of the volume illumination and the non-uniform flow seeding, the optical distortions and errors in the 3D calibration, and the unwanted flame luminosity. In the present work, the above constraints were overcome for the tomographic PIV experiment in a laminar axisymmetric premixed flame. The measurements were conducted for a 1 : 1 depth-to-size ratio using a system of eight CCD cameras and a 200 mJ pulsed laser. The results show that camera calibration based on the triangulation of the tracer particles in the non-reacting conditions provided reliable accuracy for the 3D image reconstruction in the flame. The modification of the tomographic reconstruction allowed a posteriori removal of unwanted bright objects, which were located outside of the region of interest but affected the reconstruction quality. This study reports on a novel experience for the instantaneous 3D velocimetry in laboratory-scale flames by using tomographic PIV. (paper)

  12. Computerized tomography in evaluation of the pulmonary hilum

    International Nuclear Information System (INIS)

    Secaf, M.; Ferreira, J.L.N.; Secaf, E.

    1987-01-01

    The use of computerized tomography as a method for evaluating the pulmonary hilum and its application in the diagnosis of endobronchial lesions, hilar masss, contiguous involvement of the mediastinum by hilar mass, and vascular hilar lesions are discussed. A comparative evaluation between conventional tomograms and computerized tomography is presented. (M.A.C.) [pt

  13. A Computerized QC Analysis of TLD Glow Curves for Personal Dosimetry Measurements Using Tag QC Program

    International Nuclear Information System (INIS)

    Primo, S.; Datz, H.; Dar, A.

    2014-01-01

    The External Dosimetry Lab (EDL) at the Radiation Safety Division at Soreq Nuclear Research Center (SNRC) is ISO 17025 certified and provides its services to approximately 13,000 users throughout the country from various sectors such as medical, industrial and academic. About 95% of the users are monitored monthly for X-rays, radiation using Thermoluminescence Dosimeter (TLD) cards that contain three LiF:Mg,Ti elements and the other users, who work also with thermal neutrons, use TLD cards that contain four LiF:Mg,Ti elements. All TLD cards are measured with the Thermo 8800pc reader. Suspicious TLD glow curve (GC) can cause wrong dose estimation so the EDL makes great efforts to ensure that each GC undergoes a careful QC procedure. The current QC procedure is performed manually and through a few steps using different softwares and databases in a long and complicated procedure: EDL staff needs to export all the results/GCs to be checked to an Excel file, followed by finding the suspicious GCs, which is done in a different program (WinREMS), According to the GC shapes (Figure 1 illustrates suitable and suspicious GC shapes) and the ratio between the elements result values, the inspecting technician corrects the data. The motivation for developing the new program is the complicated and time consuming process of our the manual procedure to the large amount of TLDs each month (13,000), similarly to other Dosimetry services that use computerized QC GC analysis. it is important to note that only ~25% of the results are above the EDL recorded level (0.10 mSv) and need to be inspected. Thus, the purpose of this paper is to describe a new program, TagQC, which allows a computerized QC GC analysis that identifies automatically, swiftly, and accurately suspicious TLD GC

  14. Motion tracking-enhanced MART for tomographic PIV

    International Nuclear Information System (INIS)

    Novara, Matteo; Scarano, Fulvio; Batenburg, Kees Joost

    2010-01-01

    A novel technique to increase the accuracy of multiplicative algebraic reconstruction technique (MART) reconstruction from tomographic particle image velocimetry (PIV) recordings at higher seeding density than currently possible is presented. The motion tracking enhancement (MTE) method is based on the combined utilization of images from two or more exposures to enhance the reconstruction of individual intensity fields. The working principle is first introduced qualitatively, and the mathematical background is given that explains how the MART reconstruction can be improved on the basis of an improved first guess object obtained from the combination of non-simultaneous views reduced to the same time instant deforming the 3D objects by an estimate of the particle motion field. The performances of MTE are quantitatively evaluated by numerical simulation of the imaging, reconstruction and image correlation processes. The cases of two or more exposures obtained from time-resolved experiments are considered. The iterative application of MTE appears to significantly improve the reconstruction quality, first by decreasing the intensity of the ghost images and second, by increasing the intensity and the reconstruction precision for the actual particles. Based on computer simulations, the maximum imaged seeding density that can be dealt with is tripled with respect to the MART analysis applied to a single exposure. The analysis also illustrates that the maximum effect of the MTE method is comparable to that of doubling the number of cameras in the tomographic system. Experiments performed on a transitional jet at Re = 5000 apply the MTE method to double-frame recordings. The velocity measurement precision is increased for a system with fewer views (two or three cameras compared with four cameras). The ghost particles' intensity is also visibly reduced although to a lesser extent with respect to the computer simulations. The velocity and vorticity field obtained from a three

  15. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  16. Survey of methods for improving operator acceptance of computerized aids

    International Nuclear Information System (INIS)

    Frey, P.R.; Kisner, R.A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room

  17. Survey of methods for improving operator acceptance of computerized aids

    Energy Technology Data Exchange (ETDEWEB)

    Frey, P. R.; Kisner, R. A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room.

  18. Computerized accounting methods. Final report

    International Nuclear Information System (INIS)

    1994-01-01

    This report summarizes the results of the research performed under the Task Order on computerized accounting methods in a period from 03 August to 31 December 1994. Computerized nuclear material accounting methods are analyzed and evaluated. Selected methods are implemented in a hardware-software complex developed as a prototype of the local network-based CONMIT system. This complex has been put into trial operation for test and evaluation of the selected methods at two selected ''Kurchatov Institute'' Russian Research Center (''KI'' RRC) nuclear facilities. Trial operation is carried out since the beginning of Initial Physical Inventory Taking in these facilities that was performed in November 1994. Operation of CONMIT prototype system was demonstrated in the middle of December 1994. Results of evaluation of CONMIT prototype system features and functioning under real operating conditions are considered. Conclusions are formulated on the ways of further development of computerized nuclear material accounting methods. The most important conclusion is a need to strengthen computer and information security features supported by the operating environment. Security provisions as well as other LANL Client/Server System approaches being developed by Los Alamos National Laboratory are recommended for selection of software and hardware components to be integrated into production version of CONMIT system for KI RRC

  19. Pressure spectra from single-snapshot tomographic PIV

    NARCIS (Netherlands)

    Schneiders, J.F.G.; Avallone, F.; Pröbsting, S.; Ragni, D.; Scarano, F.

    2018-01-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor’s hypothesis (TH) of frozen turbulence and

  20. A novel computerized surgeon-machine interface for robot-assisted laser phonomicrosurgery.

    Science.gov (United States)

    Mattos, Leonardo S; Deshpande, Nikhil; Barresi, Giacinto; Guastini, Luca; Peretti, Giorgio

    2014-08-01

    To introduce a novel computerized surgical system for improved usability, intuitiveness, accuracy, and controllability in robot-assisted laser phonomicrosurgery. Pilot technology assessment. The novel system was developed involving a newly designed motorized laser micromanipulator, a touch-screen display, and a graphics stylus. The system allows the control of a CO2 laser through interaction between the stylus and the live video of the surgical area. This empowers the stylus with the ability to have actual effect on the surgical site. Surgical enhancements afforded by this system were established through a pilot technology assessment using randomized trials comparing its performance with a state-of-the-art laser microsurgery system. Resident surgeons and medical students were chosen as subjects in performing sets of trajectory-following exercises. Image processing-based techniques were used for an objective performance assessment. A System Usability Scale-based questionnaire was used for the qualitative assessment. The computerized interface demonstrated superiority in usability, accuracy, and controllability over the state-of-the-art system. Significant ease of use and learning experienced by the subjects were demonstrated by the usability score assigned to the two compared interfaces: computerized interface = 83.96% versus state-of-the-art = 68.02%. The objective analysis showed a significant enhancement in accuracy and controllability: computerized interface = 90.02% versus state-of-the-art = 75.59%. The novel system significantly enhances the accuracy, usability, and controllability in laser phonomicrosurgery. The design provides an opportunity to improve the ergonomics and safety of current surgical setups. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  1. Tomographic Particle Image Velocimetry Using Colored Shadow Imaging

    KAUST Repository

    Alarfaj, Meshal K.

    2016-02-01

    Tomographic Particle Image Velocimetry Using Colored Shadow Imaging by Meshal K Alarfaj, Master of Science King Abdullah University of Science & Technology, 2015 Tomographic Particle image velocimetry (PIV) is a recent PIV method capable of reconstructing the full 3D velocity field of complex flows, within a 3-D volume. For nearly the last decade, it has become the most powerful tool for study of turbulent velocity fields and promises great advancements in the study of fluid mechanics. Among the early published studies, a good number of researches have suggested enhancements and optimizations of different aspects of this technique to improve the effectiveness. One major aspect, which is the core of the present work, is related to reducing the cost of the Tomographic PIV setup. In this thesis, we attempt to reduce this cost by using an experimental setup exploiting 4 commercial digital still cameras in combination with low-cost Light emitting diodes (LEDs). We use two different colors to distinguish the two light pulses. By using colored shadows with red and green LEDs, we can identify the particle locations within the measurement volume, at the two different times, thereby allowing calculation of the velocities. The present work tests this technique on the flows patterns of a jet ejected from a tube in a water tank. Results from the images processing are presented and challenges discussed.

  2. Computed tomographic findings of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu

    1985-01-01

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor

  3. Computed tomographic findings of traumatic intracranial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1985-10-15

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor.

  4. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka; Akagi, Kiyoshi; Uehata, Hiroshi

    1981-01-01

    In order to obtain a radioisotope (RI) tomographic image, there are various, methods, including the RCT method, Time Modulate method, and Multiple Pinhole Coded Aperture (MPCA) method and others. The MPCA method has several advantages. Using the MPCA method, there is no need to move either the detector or the patient, Furthermore, the generally used γ-camera may be used without any alterations. Due to certain problems in reconstructing the tomographic image, the use of the MPCA method in clinical practice is limited to representation of small organs (e.g. heart) using the 7-Pinhole collimator. This research presents an experimental approach to overcome the problems in reconstruction of tomographic images of large organs (organs other than the heart, such as the brain, liver, lung etc.) by introducing a reconstruction algorithm and correction software into the MPCA method. There are 2 main problems in MPCA image reconstruction: (1) Due to the rounding-off procedure, there is both point omission and shifting of point coordinates. (2) The central portion is characterized by high-counts. Both of these problems were solved by incorporating a reconstruction algorithm and a correction function. The resultant corrected tomographic image was processed using a filter derived from subjecting a PSF to a Fourier transform. Thus, it has become possible to obtain a high-quality tomographic image of large organs for clinical use. (author)

  5. Segmentation-DrivenTomographic Reconstruction

    DEFF Research Database (Denmark)

    Kongskov, Rasmus Dalgas

    such that the segmentation subsequently can be carried out by use of a simple segmentation method, for instance just a thresholding method. We tested the advantages of going from a two-stage reconstruction method to a one stage segmentation-driven reconstruction method for the phase contrast tomography reconstruction......The tomographic reconstruction problem is concerned with creating a model of the interior of an object from some measured data, typically projections of the object. After reconstructing an object it is often desired to segment it, either automatically or manually. For computed tomography (CT...

  6. Quantum probability measures and tomographic probability densities

    NARCIS (Netherlands)

    Amosov, GG; Man'ko, [No Value

    2004-01-01

    Using a simple relation of the Dirac delta-function to generalized the theta-function, the relationship between the tomographic probability approach and the quantum probability measure approach with the description of quantum states is discussed. The quantum state tomogram expressed in terms of the

  7. Phase-contrast tomographic imaging using an X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Momose, A. [Hitachi Ltd, Advanced Research Lab., Saitama (Japan); Takeda, T.; Itai, Y. [Univ. of Tsukuba, Inst. of Clinical Medicine, Ibaraki (Japan); Yoneyama, A. [Hitachi Ltd, Central Resarch Lab., Tokyo (Japan); Hirano, K. [High Energy Accelerator Research Organization, Inst. of Materials Structure Science, Ibaraki (Japan)

    1998-05-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays. 35 refs.

  8. Phase-contrast tomographic imaging using an X-ray interferometer

    International Nuclear Information System (INIS)

    Momose, A.; Takeda, T.; Itai, Y.; Yoneyama, A.; Hirano, K.

    1998-01-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays

  9. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Remacle, J.; Quoidbach, G.

    1993-01-01

    The concept of 'computerized management' of plant intervention tasks was developed by TRACTEBEL in 1983 for the Belgian power plants of ELECTRABEL. The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant in planning, organizing, and carrying out any (preventive or corrective) maintenance task. It consists of a group of interconnected functional modules acting on a unique and homogeneous data base. A short description of 3 modules is given, i.e., the 'User' Module, the 'Equipment' Module and the 'Periodic Procedure' Module. (Z.S.)

  10. Computed tomographic appearances of cherubism

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S D; Boccardi, A; Mela, F; Romagnoli, R

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression.

  11. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined

  12. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined instrument

  13. Emission computed tomograph

    International Nuclear Information System (INIS)

    Hirose, Y.; Kanno, I.; Koga, K.; Miura, S.; Uemura, K.

    1981-01-01

    Emission computed tomograph wherein a pluralty of detectors surround an object to be examined so as to detect x- or gamma radiation emitted by said object. In front of each of said detectors there is provided a collimator which comprises a pair of main plates and a subsidiary plate interposed therebetween. The plates are made of a material capable of blocking penetration of the radiation therethrough and so supported as to be swingable over an angle sufficient to cover the whole of said object. The plates of all the collimators are simultaneously swung to the same side and at the same angular speed thereby to change the direction of incidence of said radiation on each of said detectors

  14. Evaluation of supra- and infratentorial brain atrophy by computerized tomography in spinocerebellar degeneration

    International Nuclear Information System (INIS)

    Yamamoto, Hiroko; Asano, Yasuhiko; Watanabe, Takatoshi; Hirao, Yoshitaka; Mizuno, Yasushi; Sobue, Itsuro

    1986-01-01

    Measurement of various parameters of supra- and infratentorial brain atrophy in computerized tomographs of 142 cases of spinocerebellar degeneration (SCD) and 100 age and sex matched controls was carried out in order to investigate whether these parameters would correspond to the subtypes of this disease and differing grades of various clinical manifestations. One supra- and all infratentorial parameters of SCD showed statistically significant atrophy with a risk of P < 0.005. Among the subtypes, OPCA had a more severely atrophied pons than LCCA (P < 0.005), Menzel (P < 0.05) and SSP (P < 0.01). There was a correlation between the distribution of symptoms like gait, speech, ataxia of extremities and ocular movement disorders, and distribution and degree of infratentorial atrophy with statistical significance (P < 0.05 ∼ P < 0.005). The degree of atrophy of the pons and the width of the IV ventricle were directly proportional to the duration of the illness in cases of less than 10 years, but not to those of over 10 years. Follow-up CT scan was done for 24 patients, 12 within 3 years, 12 after the lapse of 3 years. The latter group showed statistically significant atrophy between the 1st and 2nd scans in several parameters, but there was no significance between those of the former group. (author)

  15. Evaluation of supra- and infratentorial brain atrophy by computerized tomography in spinocerebellar degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiroko; Asano, Yasuhiko; Watanabe, Takatoshi; Hirao, Yoshitaka; Mizuno, Yasushi; Sobue, Itsuro

    1986-08-01

    Measurement of various parameters of supra- and infratentorial brain atrophy in computerized tomographs of 142 cases of spinocerebellar degeneration (SCD) and 100 age and sex matched controls was carried out in order to investigate whether these parameters would correspond to the subtypes of this disease and differing grades of various clinical manifestations. One supra- and all infratentorial parameters of SCD showed statistically significant atrophy with a risk of P < 0.005. Among the subtypes, OPCA had a more severely atrophied pons than LCCA (P < 0.005), Menzel (P < 0.05) and SSP (P < 0.01). There was a correlation between the distribution of symptoms like gait, speech, ataxia of extremities and ocular movement disorders, and distribution and degree of infratentorial atrophy with statistical significance (P < 0.05 -- P < 0.005). The degree of atrophy of the pons and the width of the IV ventricle were directly proportional to the duration of the illness in cases of less than 10 years, but not to those of over 10 years. Follow-up CT scan was done for 24 patients, 12 within 3 years, 12 after the lapse of 3 years. The latter group showed statistically significant atrophy between the 1st and 2nd scans in several parameters, but there was no significance between those of the former group.

  16. Case Report: Unusual computed tomographic features of ...

    African Journals Online (AJOL)

    A case report of a 57-year old woman who presented with signs and symptoms of intracranial mass. Computed tomographic (CT) and clinical features were unusual and suggestive of a parasaggital Meningioma. However an accurate diagnosis of a tuberculoma was made at surgery and histopathological examination.

  17. Dental computed tomographic imaging as age estimation: morphological analysis of the third molar of a group of Turkish population.

    Science.gov (United States)

    Cantekin, Kenan; Sekerci, Ahmet Ercan; Buyuk, Suleyman Kutalmis

    2013-12-01

    Computed tomography (CT) is capable of providing accurate and measurable 3-dimensional images of the third molar. The aims of this study were to analyze the development of the mandibular third molar and its relation to chronological age and to create new reference data for a group of Turkish participants aged 9 to 25 years on the basis of cone-beam CT images. All data were obtained from the patients' records including medical, social, and dental anamnesis and cone-beam CT images of 752 patients. Linear regression analysis was performed to obtain regression formulas for dental age calculation with chronological age and to determine the coefficient of determination (r) for each sex. Statistical analysis showed a strong correlation between age and third-molar development for the males (r2 = 0.80) and the females (r2 = 0.78). Computed tomographic images are clinically useful for accurate and reliable estimation of dental ages of children and youth.

  18. Time-resolved tomographic images of a relativistic electron beam

    International Nuclear Information System (INIS)

    Koehler, H.A.; Jacoby, B.A.; Nelson, M.

    1984-07-01

    We obtained a sequential series of time-resolved tomographic two-dimensional images of a 4.5-MeV, 6-kA, 30-ns electron beam. Three linear fiber-optic arrays of 30 or 60 fibers each were positioned around the beam axis at 0 0 , 61 0 , and 117 0 . The beam interacting with nitrogen at 20 Torr emitted light that was focused onto the fiber arrays and transmitted to a streak camera where the data were recorded on film. The film was digitized, and two-dimensional images were reconstructed using the maximum-entropy tomographic technique. These images were then combined to produce an ultra-high-speed movie of the electron-beam pulse

  19. 45 CFR 307.25 - Review and certification of computerized support enforcement systems.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.25 Review and certification of computerized support enforcement systems. The Office will review, assess and inspect the... 45 Public Welfare 2 2010-10-01 2010-10-01 false Review and certification of computerized support...

  20. Three dimensional reconstruction of tomographic images of the retina

    International Nuclear Information System (INIS)

    Glittenberg, C.; Zeiler, F.; Falkner, C.; Binder, S.; Povazay, B.; Hermann, B.; Drexler, W.

    2007-01-01

    The development of a new display system for the three-dimensional visualization of tomographic images in ophthalmology. Specifically, a system that can use stacks of B-mode scans from an ultrahigh resolution optical tomography examination to vividly display retinal specimens as three-dimensional objects. Several subroutines were programmed in the rendering and raytracing program Cinema 4D XL 9.102 Studio Bundle (Maxon Computer Inc., Friedrichsburg, Germany), which could process stacks of tomographic scans into three-dimensional objects. Ultrahigh resolution optical coherence tomography examinations were performed on patients with various retinal pathologies and post processed with the subroutines that had been designed. All ultrahigh resolution optical coherence tomographies were performed with a titanium: sapphire based ultra broad bandwidth (160 nm) femtosecond laser system (INTEGRAL, Femtolasers Productions GmbH. Vienna Austria) with an axial resolution of 3 μm. A new three dimensional display system for tomographic images in ophthalmology was developed, which allows a highly vivid display of physiological and pathological structures of the retina. The system also distinguishes itself through its high interactivity and adaptability. This new display system allows the visualization of physiological and pathological structures of the retina in a new way, which will give us new insight into their morphology and development. (author) [de

  1. An introduction to the tomographic picture of quantum mechanics

    International Nuclear Information System (INIS)

    Ibort, A; Man'ko, V I; Marmo, G; Simoni, A; Ventriglia, F

    2009-01-01

    Starting from the famous Pauli problem on the possibility of associating quantum states with probabilities, the formulation of quantum mechanics in which quantum states are described by fair probability distributions (tomograms, i.e. tomographic probabilities) is reviewed in a pedagogical style. The relation between the quantum state description and the classical state description is elucidated. The difference between those sets of tomograms is described by inequalities equivalent to a complete set of uncertainty relations for the quantum domain and to non-negativity of probability density on phase space in the classical domain. The intersection of such sets is studied. The mathematical mechanism that allows us to construct different kinds of tomographic probabilities like symplectic tomograms, spin tomograms, photon number tomograms, etc is clarified and a connection with abstract Hilbert space properties is established. The superposition rule and uncertainty relations in terms of probabilities as well as quantum basic equations like quantum evolution and energy spectra equations are given in an explicit form. A method to check experimentally the uncertainty relations is suggested using optical tomograms. Entanglement phenomena and the connection with semigroups acting on simplexes are studied in detail for spin states in the case of two-qubits. The star-product formalism is associated with the tomographic probability formulation of quantum mechanics.

  2. Field experience with a mobile tomographic nondestructive assay system

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Betts, S.E.; Taggart, D.P.; Estep, R.J.; Nicholas, N.J.; Lucas, M.C.; Harlan, R.A.

    1995-01-01

    A mobile tomographic gamma-ray scanner (TGS) developed by Los Alamos National Laboratory was recently demonstrated at the Rocky Flats Environmental Technology Site and is currently in use at Los Alamos waste storage areas. The scanner was developed to assay radionuclides in low-level, transuranic, and mixed waste in containers ranging in size from 2 ft 3 boxes to 83-gallon overpacks. The tomographic imaging capability provides a complete correction for source distribution and matrix attenuation effects, enabling accurate assays of Pu-239 and other gamma-ray emitting isotopes. In addition, the system can reliably detect self-absorbing material such as plutonium metal shot, and can correct for bias caused by self-absorption. The system can be quickly configured to execute far-field scans, segmented gamma-ray scans, and a host of intermediate scanning protocols, enabling higher throughput (up to 20 drums per 8-hour shift). In this paper, we will report on the results of field trials of the mobile system at Rocky Flats and Los Alamos. Assay accuracy is confirmed for cases in which TGS assays can be compared with assays (e.g. with calorimetry) of individual packages within the drums. The mobile tomographic technology is expected to considerably reduce characterization costs at DOE production and environmental technology sites

  3. A hard tissue cephalometric comparative study between hand tracing and computerized tracing

    Directory of Open Access Journals (Sweden)

    Ramachandra Prabhakar

    2014-01-01

    Full Text Available Aims: To analyze and compare the angular and linear hard tissue cephalometric measurements using hand-tracing and computerized tracings with Nemoceph and Dolphin software systems. Subjects and Methods: A total of 30 cephalograms were randomly chosen for study with the following criteria, cephalograms of patients with good contrast, no distortion, and minimal radiographic artifacts were considered using the digital method (Kodak 8000 C with 12 angular and nine linear parameters selected for the study. Comparisons were determined by post-hoc test using Tukey HSD method. The N-Par tests were performed using Kruskal-Walli′s method. Statistical Analysis Used: ANOVA and post-hoc. Results: The results of this study show that there is no significant difference in the angular and linear measurements recorded. The P values were significant at 0.05 levels for two parameters, Co-A and Co-Gn with the hand-tracing method. This was significant in ANOVA and post-hoc test by Tukey HSD method. Conclusions: This study of comparison provides support for transition from digital hand to computerized tracing methodology. In fact, digital computerized tracings were easier and less time consuming, with the same reliability irrespective of each method of tracing.

  4. Tomographic analysis of CBF in cerebral infarction

    International Nuclear Information System (INIS)

    Segawa, Hiromu; Kimura, Kazumoto; Ueda, Yuichi; Nagai, Masakatsu; Yoshimasu, Norio.

    1983-01-01

    Cerebral perfusion was examined in various types of occlusive disease by computed tomographic CBF method. The method utilized has several advantages over conventional studies using isotope, providing high resolution images in a direct relation to CT anatomy. Ten representative cases were presented from 25 consective cases of occlusive disease studied by this method. The method included inhalation of 40 to 60% xenon with serial CT scanning for 25 min. K (build-up rate), lambda (partition coefficient) and CBF values were calculated from ΔHU for each pixel and ΔXe in expired air, based on Fick's principle, and displayed on CRT as K-, lambda- and CBF-map separately. CBF for gray matter of normal control was 82 +- 11 ml/100 gm/min and that for white matter was 24 +- 5 ml/100 gm/min. The ischemic threshold for gray matter appeared to be approximately 20 ml/100 gm/min, as blood flow in focus of complete infarction was below this level. Blood flow between 20 - 30 ml/ 100 gm/min caused some change on CT, such as localized atrophy, cortical thinning, loss of distinction between gray and white matter and decreased or increased density, which were considered to be compatible with pathological changes of laminar necrosis or gliosis with neuronal loss. In a case with occlusion of middle cerebral artery with subsequent recanalization, causing hemorrhagic infarct, hyperemia was observed in the infarcted cortex that was enhanced by iodine. Periventricular lucency observed in two cases, where blood flow was decreased below threshold, could be classified as ''watershed infarction'' mainly involving white matter. In moyamoya disease, blood flow in the anterior circulation was decreased near ischemic level, whereas that in basal ganglia and territory of posterior cerebral artery was fairly preserved, which was compatible with general angiographic finding of this disease. (author)

  5. Computerized Games and Simulations in Computer-Assisted Language Learning: A Meta-Analysis of Research

    Science.gov (United States)

    Peterson, Mark

    2010-01-01

    This article explores research on the use of computerized games and simulations in language education. The author examined the psycholinguistic and sociocultural constructs proposed as a basis for the use of games and simulations in computer-assisted language learning. Research in this area is expanding rapidly. However, to date, few studies have…

  6. Visual servoing in medical robotics: a survey. Part II: tomographic imaging modalities--techniques and applications.

    Science.gov (United States)

    Azizian, Mahdi; Najmaei, Nima; Khoshnam, Mahta; Patel, Rajni

    2015-03-01

    Intraoperative application of tomographic imaging techniques provides a means of visual servoing for objects beneath the surface of organs. The focus of this survey is on therapeutic and diagnostic medical applications where tomographic imaging is used in visual servoing. To this end, a comprehensive search of the electronic databases was completed for the period 2000-2013. Existing techniques and products are categorized and studied, based on the imaging modality and their medical applications. This part complements Part I of the survey, which covers visual servoing techniques using endoscopic imaging and direct vision. The main challenges in using visual servoing based on tomographic images have been identified. 'Supervised automation of medical robotics' is found to be a major trend in this field and ultrasound is the most commonly used tomographic modality for visual servoing. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Computed tomographic study of 50 patients with hypodense hepatic injuries in childhood

    International Nuclear Information System (INIS)

    Pereira, Ines Minniti Rodrigues; Alvares, Beatriz Regina; Baracat, Jamal; Martins, Daniel Lahan; Pereira, Ricardo Minniti Rodrigues

    2006-01-01

    Objective: To describe the different tomographic findings in hypodense hepatic lesions in children and its differential diagnosis. Materials and methods: computed tomographic studies were obtained from 50 patients (age range: 0-16 years) with low-density liver lesions previously diagnosed by ultrasound. Images were made before and after administration of intravenous contrast medium. Image findings were analyzed and afterwards correlated with anatomopathological diagnosis. Results: forty-seven of 50 cases were confirmed, 30 by anatomopathological diagnosis. Most of then were benign lesions, hemangioma in 20%. Such lesions presented a homogeneous contrast absorption, mainly at the delayed phase, differing from malignant lesions. Metastasis was the most frequently found malignant lesion (18%). Conclusion: computed tomographic study is of great value in complementing the diagnosis of hypodense hepatic lesions in children, and must follow ultrasound diagnosis as a routine procedure. (author)

  8. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    International Nuclear Information System (INIS)

    Staton, R J; Pazik, F D; Nipper, J C; Williams, J L; Bolch, W E

    2003-01-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult

  9. X-ray Tomographic Microscopy at TOMCAT

    Energy Technology Data Exchange (ETDEWEB)

    Marone, F; Hintermueller, C; McDonald, S; Abela, R; Mikuljan, G; Isenegger, A; Stampanoni, M, E-mail: federica.marone@psi.c [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland)

    2009-09-01

    Synchrotron-based X-ray Tomographic Microscopy is a powerful technique for fast non-destructive, high resolution quantitative volumetric investigations on diverse samples. At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline at the Swiss Light Source, synchrotron light is delivered by a 2.9 T superbend. The main optical component, a Double Crystal Multilayer Monochromator, covers an energy range between 8 and 45 keV. The standard TOMCAT detector offers field of views ranging from 0.75x0.75 mm{sup 2} up to 12.1x12.1 mm{sup 2} with a pixel size of 0.37 {mu}m and 5.92 {mu}m, respectively. In addition to routine measurements, which exploit the absorption contrast, the high coherence of the source also enables phase contrast tomography, implemented with two complementary techniques (Modified Transport of Intensity approach and Grating Interferometry). Typical acquisition times for a tomogram are in the order of few minutes, ensuring high throughput and allowing for semi-dynamical investigations. Raw data are automatically post-processed online and full reconstructed volumes are available shortly after a scan with minimal user intervention.

  10. MCPT: A Monte Carlo code for simulation of photon transport in tomographic scanners

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Gardner, R.P.; Verghese, K.

    1990-01-01

    MCPT is a special-purpose Monte Carlo code designed to simulate photon transport in tomographic scanners. Variance reduction schemes and sampling games present in MCPT were selected to characterize features common to most tomographic scanners. Combined splitting and biasing (CSB) games are used to systematically sample important detection pathways. An efficient splitting game is used to tally particle energy deposition in detection zones. The pulse height distribution of each detector can be found by convolving the calculated energy deposition distribution with the detector's resolution function. A general geometric modelling package, HERMETOR, is used to describe the geometry of the tomographic scanners and provide MCPT information needed for particle tracking. MCPT's modelling capabilites are described and preliminary experimental validation is presented. (orig.)

  11. Results of CT brain examinations in cerebrovascular emergency. [computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pinta, Z; Dolansky, J; Sorfova, J; Jerie, T

    1987-07-01

    Experience is briefly reported with CT (computerized tomography) diagnosis of cerebrovascular emergencies. It is pointed out that the introduction of computerized tomography greatly improved and made more accurate the diagnosis of focal ischemias and revealed significant differences in the foci of ischemia in hypertension patients and atherosclerosis patients without hypertension, and showed a higher incidence of intracerebral and subarachnoidal hemorrhages than previously thought. It is believed that knowledge gained thanks to CT (computerized tomography) will be of benefit to the primary and secondary prevention of cerebrovascular ischemias. (L.O.). 1 fig., 5 refs.

  12. Tomographic examination table

    International Nuclear Information System (INIS)

    Redington, R.W.; Henkes, J.L.

    1979-01-01

    Equipment is described for positioning and supporting patients during tomographic mammography using X-rays. The equipment consists of a table and fabric slings which permit the examination of a downward, pendant breast of a prone patient by allowing the breast to pass through a aperture in the table into a fluid filled container. The fluid has an X-ray absorption coefficient similar to that of soft human tissue allowing high density resolution radiography and permitting accurate detection of breast tumours. The shape of the equipment and the positioning of the patient allow the detector and X-ray source to rotate 360 0 about a vertical axis through the breast. This permits the use of relatively simple image reconstruction algorithms and a divergent X-ray geometry. (UK)

  13. Photon emission tomographic apparatus and method

    International Nuclear Information System (INIS)

    Blum, A.S.

    1983-01-01

    Tomographic imaging system employs large area, collimated scintillation detector rotated around radiation emitting subject. Detector support rotates with an inner ring inside a stationary outer ring. Counterbalanced detector support arm is forced by spring action to cause collimator face to follow body contour as detector rotates around the body, thereby reducing collimator to subject distance to improve system resolution. Includes adjustable subject support system

  14. Computerized tomography with X-rays: an instrument in the analysis physico-chemical between formations and drilling fluids interactions

    International Nuclear Information System (INIS)

    Coelho, Marcus Vinicius Cavalcante

    1998-01-01

    In this study it is demonstrated the applicability of the Computerized Tomography technique with x-rays to evaluate the reactivity degree between various drilling fluids and argillaceous sediments (Shales and Sandstones). The research has been conducted in the Rock-Fluid Interaction Pressure Simulator (RFIPS), where the possible physico-chemical alterations can be observed through successive tomography images, which are obtained during the flow of the fluid through the samples. In addition, it was noticed the formation of mud cake in Berea Sandstones samples in the RFIPS, though the Computerized Tomography with X-rays, when utilizing drilling fluids weighted with the baryte. (author)

  15. Study on computerized presentation of emergency procedures of a nuclear plant (step 2). The guidelines of the prototype of the computerized procedure presentation system

    International Nuclear Information System (INIS)

    Niwa, Yuji; Hollnagel, E.; Iwaki, Toshio.

    1995-01-01

    New methods of information presentation and interface design are changing the working conditions in the modern Nuclear Power Plant (NPP) control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOPs), which plays an essential role in NPPs. Conventionally procedures are presented in a hard copy form. However developments in information technology have offered new opportunities for the computerization of such procedures. Consideration for the first stage of computerization should be focused upon the presentation of procedures. The specification of the computerized presentation of procedures is discussed with respect to the issues which were central to the project: navigation through procedures; formatting and presentation of procedures; and process monitoring. Issues that would be included in more advanced systems, such as help and explanation facilities features, and process linking, are also discussed. This paper deals with the specific design guidelines that were implemented for the computerization of procedure presentation. Issues of principal concern that were identified from this experience are highlighted, such as the relationship between procedure presentation and format; the registration of progress through a procedure; compensation for the limitations of computer displays versus printed documents; and the way in which the added capabilities of computerized presentation can be generally utilized in the operators' working environment. (author)

  16. Computerized tomography in the diagnosis of hyperparathyroidism

    International Nuclear Information System (INIS)

    Sobota, J.; Girl, J.; Sotornik, I.; Kocandrle, V.

    1990-01-01

    Long-term experience in the application of computerized tomography to the diagnosis of hyperparathyroidism is summarized. Based on a large number of examinations (164) of parathyroid glands associated with the possibility of verification and comparison with the results of ultrasonography and other imaging methods, the potential of computerized tomography in the diagnosis of hyperparathyroidism and its advantages and limitations are summarized. It is concluded that owing to its high diagnostic precision, this technique can be regarded reliable in detecting enlarged parathyroid glands. (author). 11 figs., 1 tab., 19 refs

  17. Industrial dynamic tomographic reconstruction; Reconstrucao tomografica dinamica industrial

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Eric Ferreira de

    2016-07-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  18. Twelve years nuclear medicine - results and outlook - illustrated by 7414 cerebral scintigrams

    International Nuclear Information System (INIS)

    Klaeger, R.

    1981-01-01

    It is a fact that until the invention of computerized tomography, scintiscanning was an excellent method for diagnosing tumours, metastases, vascular processes, inflammations and traumatic lesions. Now even the differential diagnosis is possible, and also follow-up examinations are often carried out. On the basis of the 7414 considered and studied scintigrams we came to the positive result that in most cases with deliberate questions directed to specific facts, this examination procedure was applied. Scintigraphy can be considered as the predecessor of computerized tomography. With respect to differential diagnostics the following can be said: Cerebral scintigraphy measures in cases of cerebral lesions only masses, whereas the computerized tomograph permits within certain limits even the differentiation between lesion and perifocal oedema. The tomographs of the last generation even differentiate between white and grey cerebral substance. Nevertheless, the residual domaine of scintigraphy remains untouched: the patients with non-focal symptoms, including headaches, general behaviour disorders and psychiatric processes. (orig./MG) [de

  19. Quality criteria in computerized tomography of the chest

    International Nuclear Information System (INIS)

    Doehring, W.

    1985-01-01

    The quality of thoracical computerized tomography (CT) - like any other CT examination - depends from the quality of the equipment used, from the skill of the examinor and the properties of the patient. Concerning computerized chest tomograms, rapid scan equipment should be used only and slow translation - rotation systems should not be used any more. Whereas the quality of computerized tomograms may be influenced by the patient in the scanning process only, the examining physician will decisively influence the possible informative value of the examination also in the reconstruction of the CT value matrix, in single demonstration of CT values and, possibly, in additional measurement value processing as well as in the interpretation of findings. Use of equipment should always consider the technical potential provided by the equipment to be oriented to the clinical issue, and the conditions preset by the patient. (orig.) [de

  20. Development of computerized risk management tool

    International Nuclear Information System (INIS)

    Kil Yoo Kim; Mee Jung Hwang; Seung Cheol Jang; Sang Hoon Han; Tae Woon Kim

    1997-01-01

    The author describes the kinds of efforts for the development of computerized risk management tool; (1) development of a risk monitor, Risk Monster, (2) improvement of McFarm (Missing Cutsets Finding Algorithm for Risk Monitor) and finally (3) development of reliability database management system, KwDBMan. Risk Monster supports for plant operators and maintenance schedulers to monitor plant risk and to avoid high peak risk by rearranging maintenance work schedule. Improved McFarm significantly improved calculation speed of Risk Monster for the cases of supporting system OOS (Out Of Service). KwDBMan manages event data, generic data and CCF (Common Cause Failure) data to support Risk Monster as well as PSA tool, KIRAP (KAERI Integrated Reliability Analysis Package)

  1. Computerized heat balance models to predict performance of operating nuclear power plants

    International Nuclear Information System (INIS)

    Breeding, C.L.; Carter, J.C.; Schaefer, R.C.

    1983-01-01

    The use of computerized heat balance models has greatly enhanced the decision making ability of TVA's Division of Nuclear Power. These models are utilized to predict the effects of various operating modes and to analyze changes in plant performance resulting from turbine cycle equipment modifications with greater speed and accuracy than was possible before. Computer models have been successfully used to optimize plant output by predicting the effects of abnormal condenser circulating water conditions. They were utilized to predict the degradation in performance resulting from installation of a baffle plate assembly to replace damaged low-pressure blading, thereby providing timely information allowing an optimal economic judgement as to when to replace the blading. Future use will be for routine performance test analysis. This paper presents the benefits of utility use of computerized heat balance models

  2. Computerized systems of NPP operators support. (Psychological problems)

    International Nuclear Information System (INIS)

    Mashin, V.A.

    1995-01-01

    Operator psychological problems arising in the work with NPP operators support computerized systems (OSCS) are considered. The conclusion is made that the OSCS intellectual application will bring the operator into dangerous dependence on his computerized assistant. To avoid this danger it is necessary by creation of the OSCS to divide specially the tasks areas of the operator and OSCS in order to assure the active role of the operator in the NPP control

  3. Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics

    Science.gov (United States)

    Yu, Tao; Cai, Weiwei; Liu, Yingzheng

    2018-04-01

    Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.

  4. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Quoidbach, G.

    2004-01-01

    The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant or of any other complex industrial facility (chemical industries, refineries, and so on) in planning, organizing, and carrying out any (preventive or corrective) maintenance task. This 'Computerized Management of Plant Intervention Tasks' is organized around a data base of all plant components in the facility that might be subjected to maintenance or tagout. It allows to manage, by means of intelligent and configurable 'mail service', the course of the intervention requests as well as various treatments of those requests, in a safe and efficient way, adapted to each particular organization. The concept of 'Computerized Management' of plant intervention tasks was developed by BELGATOM in 1983 for the Belgian nuclear power plants of ELECTRABEL. A first implementation of this concept was made at that time for the Doel NPP under the name POPIT (Programming Of Plant Intervention Tasks). In 1988, it was decided to proceed to a functional upgrade of the application, using advanced software and hardware techniques and products, and to realize a second implementation in the Tihange NPP under the name ACM (Application Consignation Maintenance). (author)

  5. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Visser, M de; Verbeeten, Jr, B J

    1988-06-04

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs.

  6. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    International Nuclear Information System (INIS)

    Visser, M. de; Verbeeten, B.J. Jr.

    1988-01-01

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs

  7. High-throughput full-automatic synchrotron-based tomographic microscopy

    International Nuclear Information System (INIS)

    Mader, Kevin; Marone, Federica; Hintermueller, Christoph; Mikuljan, Gordan; Isenegger, Andreas; Stampanoni, Marco

    2011-01-01

    At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 (micro)m to 7.4 (micro)m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 (micro)m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

  8. MDCT for computerized volumetry of pneumothoraces in pediatric patients.

    Science.gov (United States)

    Cai, Wenli; Lee, Edward Y; Vij, Abhinav; Mahmood, Soran A; Yoshida, Hiroyuki

    2011-03-01

    Our purpose in this study was to develop an automated computer-aided volumetry (CAV) scheme for quantifying pneumothorax in multidetector computed tomography (MDCT) images for pediatric patients and to investigate the imaging parameters that may affect its accuracy. Fifty-eight consecutive pediatric patients (mean age 12 ± 6 years) with pneumothorax who underwent MDCT for evaluation were collected retrospectively for this study. All cases were imaged by a 16- or 64-MDCT scanner with weight-based kilovoltage, low-dose tube current, 1.0-1.5 pitch, 0.6-5.0 mm slice thickness, and a B70f (sharp) or B31f (soft) reconstruction kernel. Sixty-three pneumothoraces ≥1 mL were visually identified in the left (n = 30) and right (n = 33) lungs. Each identified pneumothorax was contoured manually on an Amira workstation V4.1.1 (Mercury Computer Systems, Chelmsford, MA) by two radiologists in consensus. The computerized volumes of the pneumothoraces were determined by application of our CAV scheme. The accuracy of our automated CAV scheme was evaluated by comparison between computerized volumetry and manual volumetry, for the total volume of pneumothoraces in the left and right lungs. The mean difference between the computerized volumetry and the manual volumetry for all 63 pneumothoraces ≥1 mL was 8.2%. For pneumothoraces ≥10 mL, ≥50 mL, and ≥200 mL, the mean differences were 7.7% (n = 57), 7.3% (n = 33), and 6.4% (n = 13), respectively. The correlation coefficient was 0.99 between the computerized volume and the manual volume of pneumothoraces. Bland-Altman analysis showed that computerized volumetry has a mean difference of -5.1% compared to manual volumetry. For all pneumothoraces ≥10 mL, the mean differences for slice thickness ≤1.25 mm, = 1.5 mm, and = 5.0 mm were 6.1% (n = 28), 3.5% (n = 10), and 12.2% (n = 19), respectively. For the two reconstruction kernels, B70f and B31f, the mean differences were 6.3% (n = 42, B70f) and 11.7% (n = 15, B31f

  9. The computerized OMAHA system in microsoft office excel.

    Science.gov (United States)

    Lai, Xiaobin; Wong, Frances K Y; Zhang, Peiqiang; Leung, Carenx W Y; Lee, Lai H; Wong, Jessica S Y; Lo, Yim F; Ching, Shirley S Y

    2014-01-01

    The OMAHA System was adopted as the documentation system in an interventional study. To systematically record client care and facilitate data analysis, two Office Excel files were developed. The first Excel file (File A) was designed to record problems, care procedure, and outcomes for individual clients according to the OMAHA System. It was used by the intervention nurses in the study. The second Excel file (File B) was the summary of all clients that had been automatically extracted from File A. Data in File B can be analyzed directly in Excel or imported in PASW for further analysis. Both files have four parts to record basic information and the three parts of the OMAHA System. The computerized OMAHA System simplified the documentation procedure and facilitated the management and analysis of data.

  10. Analysis of risk in computerized tomography and other diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Mossman, K.L.

    1982-01-01

    Medical practice entails continuous risks to the patient taken in good faith by the physician for the benefit of the patient. Risk of radiation induced cancer death approximates 10(-4) per cGy (rad). Assuming an average whole body dose of 0.1 cGy for many diagnostic X-ray procedures, the probability of radiation-induced cancer death is about 10(-5). The purpose of this paper is to compare the risks of common diagnostic X-ray procedures including computerized tomography (CT) with risks of smoking or automobile travel. Such comparisons should be constructive in putting radiation in perspective and facilitating explanation of risk/benefit to patients

  11. Permeability Surface of Deep Middle Cerebral Artery Territory on Computed Tomographic Perfusion Predicts Hemorrhagic Transformation After Stroke.

    Science.gov (United States)

    Li, Qiao; Gao, Xinyi; Yao, Zhenwei; Feng, Xiaoyuan; He, Huijin; Xue, Jing; Gao, Peiyi; Yang, Lumeng; Cheng, Xin; Chen, Weijian; Yang, Yunjun

    2017-09-01

    Permeability surface (PS) on computed tomographic perfusion reflects blood-brain barrier permeability and is related to hemorrhagic transformation (HT). HT of deep middle cerebral artery (MCA) territory can occur after recanalization of proximal large-vessel occlusion. We aimed to determine the relationship between HT and PS of deep MCA territory. We retrospectively reviewed 70 consecutive acute ischemic stroke patients presenting with occlusion of the distal internal carotid artery or M1 segment of the MCA. All patients underwent computed tomographic perfusion within 6 hours after symptom onset. Computed tomographic perfusion data were postprocessed to generate maps of different perfusion parameters. Risk factors were identified for increased deep MCA territory PS. Receiver operating characteristic curve analysis was performed to calculate the optimal PS threshold to predict HT of deep MCA territory. Increased PS was associated with HT of deep MCA territory. After adjustments for age, sex, onset time to computed tomographic perfusion, and baseline National Institutes of Health Stroke Scale, poor collateral status (odds ratio, 7.8; 95% confidence interval, 1.67-37.14; P =0.009) and proximal MCA-M1 occlusion (odds ratio, 4.12; 95% confidence interval, 1.03-16.52; P =0.045) were independently associated with increased deep MCA territory PS. Relative PS most accurately predicted HT of deep MCA territory (area under curve, 0.94; optimal threshold, 2.89). Increased PS can predict HT of deep MCA territory after recanalization therapy for cerebral proximal large-vessel occlusion. Proximal MCA-M1 complete occlusion and distal internal carotid artery occlusion in conjunction with poor collaterals elevate deep MCA territory PS. © 2017 American Heart Association, Inc.

  12. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  13. Research

    African Journals Online (AJOL)

    abp

    2014-05-10

    May 10, 2014 ... Key words: Computerized Tomographic Scan, chronic rhinosinusitis, nasal discharge, nasal .... evaluated using bone window (window width 2,000 Hounsfield units ..... paranasal sinuses and chronic sinusitis in children.

  14. Constraining fault interpretation through tomographic velocity gradients: application to northern Cascadia

    Directory of Open Access Journals (Sweden)

    K. Ramachandran

    2012-02-01

    Full Text Available Spatial gradients of tomographic velocities are seldom used in interpretation of subsurface fault structures. This study shows that spatial velocity gradients can be used effectively in identifying subsurface discontinuities in the horizontal and vertical directions. Three-dimensional velocity models constructed through tomographic inversion of active source and/or earthquake traveltime data are generally built from an initial 1-D velocity model that varies only with depth. Regularized tomographic inversion algorithms impose constraints on the roughness of the model that help to stabilize the inversion process. Final velocity models obtained from regularized tomographic inversions have smooth three-dimensional structures that are required by the data. Final velocity models are usually analyzed and interpreted either as a perturbation velocity model or as an absolute velocity model. Compared to perturbation velocity model, absolute velocity models have an advantage of providing constraints on lithology. Both velocity models lack the ability to provide sharp constraints on subsurface faults. An interpretational approach utilizing spatial velocity gradients applied to northern Cascadia shows that subsurface faults that are not clearly interpretable from velocity model plots can be identified by sharp contrasts in velocity gradient plots. This interpretation resulted in inferring the locations of the Tacoma, Seattle, Southern Whidbey Island, and Darrington Devil's Mountain faults much more clearly. The Coast Range Boundary fault, previously hypothesized on the basis of sedimentological and tectonic observations, is inferred clearly from the gradient plots. Many of the fault locations imaged from gradient data correlate with earthquake hypocenters, indicating their seismogenic nature.

  15. X-ray tomographic apparatus

    International Nuclear Information System (INIS)

    Walters, R.G.

    1982-01-01

    An x-ray tomographic system consists of a radiation source such as gamma or x radiation which produces a fan-shaped beam. The fan is wide enough to encompass the patient circle. The system further includes means for rotating the radiation source about the patient for less than a full rotation, and detectors for detecting the radiation at positions that surround the patient by 180 0 plus the angle of the fan beam plus the angle between adjacent fan detectors. Attenuation data from the detectors is sorted into detector fans of attenuation data, then processed. The convolved data is back-projected into an image memory and displayed on a video monitor

  16. X-ray Tomographic Analysis of Porosity Distributions in Gas Diffusion Layers of Proton Exchange Membrane Fuel Cells

    International Nuclear Information System (INIS)

    Odaya, S.; Phillips, R.K.; Sharma, Y.; Bellerive, J.; Phillion, A.B.; Hoorfar, M.

    2015-01-01

    This paper describes a method to characterize the structure of polytetrafluoroethylene (PTFE) treated gas diffusion layers (GDLs) with and without microporous layers (MPLs) using 3D X-ray micro computed tomographic (μCT) microscopy. In this work, the structure of single and dual layer GDLs is evaluated via μCT for various GDL samples (such as Toray TGP-H-060 and AvCarb EP40) loaded with different MPLs. A new method is presented for separating, or segmenting, the various phases of the GDL, i.e., void space, carbon fiber (including binder and PTFE), and MPL. Through analysis, it was found that the variation in bulk porosity and the average pore diameter of the GDLs depends highly on the GDL series manufacturing and treatment processes. Using advanced image analysis techniques, routines were developed to accurately segment the GDL fibers (including binder/PTFE) and the MPL. The percentage of the intruding MPL material into the carbon fiber paper as a function of the GDL thickness was successfully found for dual layer GDLs, with varying PTFE content and areal weight loading in the MPL. This analysis provides invaluable insight into the physical microstructure of paper-based GDLs, emphasizing the heterogeneous porosity distribution of single layer GDLs and the interaction of the MPL with the carbon fiber paper of dual layer GDLs

  17. Antipsychotic treatment in schizophrenia: the role of computerized neuropsychological assessment.

    Science.gov (United States)

    Kertzman, Semion; Reznik, Ilya; Grinspan, Haim; Weizman, Abraham; Kotler, Moshe

    2008-01-01

    The present study analyzes the role of neurocognitive assessment instruments in the detection of the contribution of antipsychotic treatment to cognitive functioning. Recently, a panel of experts suggested six main domains (working memory; attention/vigilance; verbal/visual learning and memory; reasoning and problem solving; speed of processing) implicated in schizophrenia-related cognitive deficits, which serve as a theoretical base for creation of real-time computerized neurocognitive batteries. The high sensitivity of computerized neuropsychological testing is based on their ability to adopt the reaction time (RT) paradigm for the assessment of brain function in a real-time regime. This testing is highly relevant for the monitoring of the cognitive effects of antipsychotics. Computerized assessment assists in the identification of state- and trait-related cognitive impairments. The optimal real-time computerized neurocognitive battery should composite balance between broad and narrow coverage of cognitive domains relevant to the beneficial effects of antipsychotics and will enable better planning of treatment and rehabilitation programs.

  18. Directional fine structure in absorption of white x rays: A tomographic interpretation

    International Nuclear Information System (INIS)

    Korecki, P.; Szymonski, M.; Tolkiehn, M.; Novikov, D. V.; Materlik, G.

    2006-01-01

    We discuss directional fine structure in absorption of white x rays for tomographic imaging of crystal structure at the atomic level. The interference between a direct x-ray beam and the secondary waves coherently scattered inside a specimen modifies the total wave field at the position of the absorbing atoms. For a white x-ray beam, the wave field variations cancel out by energy integration for all directions, except for the near forward scattering components, coinciding with the incident beam. Therefore, two-dimensional patterns of the angular-dependent fine structure in absorption of white x rays can be interpreted as real-space projections of atomic structure. In this work, we present a theory describing the directional fine structure in white x-ray absorption and a tomographic approach for crystal structure retrieval developed on its basis. The tomographic algorithm is applied to the experimental x-ray absorption data recorded for GaP crystals

  19. Characterization of tomographically faithful states in terms of their Wigner function

    International Nuclear Information System (INIS)

    D'Ariano, G M; Sacchi, M F

    2005-01-01

    A bipartite quantum state is tomographically faithful when it can be used as an input of a quantum operation acting on one of the two quantum systems, such that the joint output state carries complete information about the operation itself. Tomographically faithful states are a necessary ingredient for the tomography of quantum operations and for complete quantum calibration of measuring apparatuses. In this paper we provide a complete classification of such states for continuous variables in terms of the Wigner function of the state. For two-mode Gaussian states faithfulness simply resorts to correlation between the modes

  20. Effect of Donepezil on Wernicke Aphasia After Bilateral Middle Cerebral Artery Infarction: Subtraction Analysis of Brain F-18 Fluorodeoxyglucose Positron Emission Tomographic Images.

    Science.gov (United States)

    Yoon, Seo Yeon; Kim, Je-Kyung; An, Young-Sil; Kim, Yong Wook

    2015-01-01

    Aphasia is one of the most common neurologic deficits occurring after stroke. Although the speech-language therapy is a mainstream option for poststroke aphasia, pharmacotherapy is recently being tried to modulate different neurotransmitter systems. However, the efficacy of those treatments is still controversial. We present a case of a 53-year-old female patient with Wernicke aphasia, after the old infarction in the territory of left middle cerebral artery for 8 years and the recent infarction in the right middle cerebral artery for 4 months. On the initial evaluation, the Aphasia Quotient in Korean version of the Western Aphasia Battery was 25.6 of 100. Baseline brain F-18 fluorodeoxyglucose positron emission tomographic images demonstrated a decreased cerebral metabolism in the left temporoparietal area and right temporal lobe. Donepezil hydrochloride, a reversible acetylcholinesterase inhibitor, was orally administered 5 mg/d for 6 weeks after the initial evaluation and was increased to 10 mg/d for the following 6 weeks. After the donepezil treatment, the patient showed improvement in language function, scoring 51.0 of 100 on Aphasia Quotient. A subtraction analysis of the brain F-18 fluorodeoxyglucose positron emission tomographic images after donepezil medication demonstrated increased uptake in both middle temporal gyri, extended to the occipital area and the left cerebellum. Thus, we suggest that donepezil can be an effective therapeutic choice for the treatment of Wernicke aphasia.

  1. Bone densitometry with the computer tomograph

    International Nuclear Information System (INIS)

    Weiss, T.

    1978-01-01

    This work tests the usefulness of the EMI head scanner MARK I for a quantitative detection of ossary mineral content. Twenty-three concentration levels of a aqueous K 2 HPO 4 -solution were positioned by means of a special clamping device at the EMI-scanner and examined at tubevoltages of 100, 120 and 140 kV. This produces an almost linear dependence between CT-unit and sample concentration, whereby it shows that the measured special element densities of samples with the same densities vary in dependence with the voltage. The examination of an anotomical fore-arm preperate served as a statement for the reproductability of computer tomographic densitometry at non-moving biological objects. The test of reproductability of bone densitometry measurements under clinical conditions was made on the occation of the six time examinations of the right hand fore-arm bone of a young dummy. Furthermore densitometric examination were made at the fore-arm shelton of 40 long-time dialysis patients in the age levels between 17 and 67 years. The reproductability of the technique presented here is at least not better with the EMI-head-scanner MARK I used here. A change is possible by using the new whole body tomographs. (orig./MG) [de

  2. Computerized operation of the DIII-D neutral beams

    International Nuclear Information System (INIS)

    Glad, A.S.; Tooker, J.F.

    1986-01-01

    Operation of the DIII-D neutral beams utilizes computerized control to provide routine tokamak beam heating shots and an effective method for automatic ion source operation. Computerized control reduces operational complexity, thus providing consistent reliability and availability of beams and a significant reduction in the the costs of routine operation. The objectives in implementing computerized control for operation were: (1) to improve operator efficiency for controlling multiple beam lines and increasing beam availability through standard procedures, (2) to provide a simplified scheme that operators and coordinators can construct and maintain, and (3) to provide a single integrated mechanism for both tokamak operation and automatic source conditioning. The years of experience in operating neutral beams at Doublet III provided the data necessary to meet the objectives. The method for computerized control consisted of three integrated functions: (1) a structured command language was implemented to provide the mechanism for automatically sequencing beams, (2) a historical file was constructed from the operational parameters to characterize the ion source, and consists of data from approximately 100,000 beam shots, and (3) procedures were developed integrating the language to the historical file for normal operation and source conditioning. This paper describes the method for sequencing beams automatically, the structure of the historical data file, and the procedures which integrate the historical data with tokamak operation and automatic source conditioning

  3. Development and Evaluation of a Confidence-Weighting Computerized Adaptive Testing

    Science.gov (United States)

    Yen, Yung-Chin; Ho, Rong-Guey; Chen, Li-Ju; Chou, Kun-Yi; Chen, Yan-Lin

    2010-01-01

    The purpose of this study was to examine whether the efficiency, precision, and validity of computerized adaptive testing (CAT) could be improved by assessing confidence differences in knowledge that examinees possessed. We proposed a novel polytomous CAT model called the confidence-weighting computerized adaptive testing (CWCAT), which combined a…

  4. Pain Perception: Computerized versus Traditional Local Anesthesia in Pediatric Patients.

    Science.gov (United States)

    Mittal, M; Kumar, A; Srivastava, D; Sharma, P; Sharma, S

    2015-01-01

    Local anesthetic injection is one of the most anxiety- provoking procedure for both children and adult patients in dentistry. A computerized system for slow delivery of local anesthetic has been developed as a possible solution to reduce the pain related to the local anesthetic injection. The present study was conducted to evaluate and compare pain perception rates in pediatric patients with computerized system and traditional methods, both objectively and subjectively. It was a randomized controlled study in one hundred children aged 8-12 years in healthy physical and mental state, assessed as being cooperative, requiring extraction of maxillary primary molars. Children were divided into two groups by random sampling - Group A received buccal and palatal infiltration injection using Wand, while Group B received buccal and palatal infiltration using traditional syringe. Visual Analog scale (VAS) was used for subjective evaluation of pain perception by patient. Sound, Eye, Motor (SEM) scale was used as an objective method where sound, eye and motor reactions of patient were observed and heart rate measurement using pulse oximeter was used as the physiological parameter for objective evaluation. Patients experienced significantly less pain of injection with the computerized method during palatal infiltration, while less pain was not statistically significant during buccal infiltration. Heart rate increased during both buccal and palatal infiltration in traditional and computerized local anesthesia, but difference between traditional and computerized method was not statistically significant. It was concluded that pain perception was significantly more during traditional palatal infiltration injection as compared to computerized palatal infiltration, while there was no difference in pain perception during buccal infiltration in both the groups.

  5. Computerized medical convocations

    International Nuclear Information System (INIS)

    Roche, Annie; Gilbert, Jean-Francois; Chiadot, Pierre; Vanzetto, Rene; Darnault, Jean

    1969-06-01

    Thanks to a close collaboration between the Medical and Social department and the Numerical Calculation Laboratory, a computerized convocation system has been implemented to reduce the administrative workload and to introduce more rigor in medical management, patient historical background and statistics. This work comprises: - a preliminary study of the data generating medical convocations and the related practical requirements; - the programming work according to these data; - the realisation of the mechano-graphical file covering the overall personnel [fr

  6. Computerized tomography in atypical Pott's disease

    International Nuclear Information System (INIS)

    Cabrera, M.N.B.; Wang, E.H.M.

    1993-01-01

    Classical Pott's disease is described as a two-vertebrae disease with the destruction of the intervening invertebral disc. Computerized tomography has been used in the differential diagnosis of spine infections and neoplasms. We reviewed CT scans of patients seen at the Philippine General Hospital over a two-year period with atypical presentations of atypical tuberculous spondylitis. We used the computerized tomography findings described as characteristic of classical Pott's disease as criteria in evaluating the CT scans of patients diagnosed to have Atypical Pott's Disease. Although the number of patients prevented sensitivity and specificity studies to be done, our results strongly suggest that the same CT criteria used to diagnose Classical Pott's Disease may also be used to diagnose Pott's disease in its atypical form. (Author.). 13 refs

  7. Tomographic evaluation of a dual-head positron emission tomography system

    International Nuclear Information System (INIS)

    Efthimiou, N; Maistros, S; Tripolitis, X; Panayiotakis, G; Samartzis, A; Loudos, G

    2011-01-01

    In this paper we present the performance evaluation results, in the planar and tomographic modes, of a low-cost positron emission tomography camera dedicated to small-animal imaging. The system consists of two pixelated Lu 2 SiO 5 crystals, two Hamamatsu H8500 position sensitive photomultiplier tubes, fast amplification electronics and an FPGA-USB-based read-out system. The parameters that have been studied are (i) saturation as a function of the head distance and photon acceptance angle, (ii) effect of the number of projections and half or complete head's rotation, (iii) spatial resolution as a function of the head distance, (iv) spatial resolution as a function of acceptance angle, (v) system's sensitivity as a function of these parameters and (vi) performance in small mice imaging. Image reconstruction has been carried out using open source software developed by our group (QSPECT), which is designed mainly for SPECT imaging. The results indicate that the system has a linear response for activities up to at least 2 MBq, which are typical in small-animal imaging. Best tomographic spatial resolution was measured to be ∼2 mm. The system has been found suitable for imaging of small mice both in the planar and tomographic modes

  8. Experimental device, corresponding forward model and processing of the experimental data using wavelet analysis for tomographic image reconstruction applied to eddy current nondestructive evaluation

    International Nuclear Information System (INIS)

    Joubert, P.Y.; Madaoui, N.

    1999-01-01

    In the context of eddy current non destructive evaluation using a tomographic image reconstruction process, the success of the reconstruction depends not only on the choice of the forward model and of the inversion algorithms, but also on the ability to extract the pertinent data from the raw signal provided by the sensor. We present in this paper, an experimental device designed for imaging purposes, the corresponding forward model, and a pre-processing of the experimental data using wavelet analysis. These three steps implemented with an inversion algorithm, will allow in the future to perform image reconstruction of 3-D flaws. (authors)

  9. The computed tomographic appearances of cherubism

    International Nuclear Information System (INIS)

    Bianchi, S.D.; Boccardi, A.; Mela, F.; Romagnoli, R.

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression. (orig.)

  10. Computerized neurocognitive testing in the management of sport-related concussion: an update.

    Science.gov (United States)

    Resch, Jacob E; McCrea, Michael A; Cullum, C Munro

    2013-12-01

    Since the late nineties, computerized neurocognitive testing has become a central component of sport-related concussion (SRC) management at all levels of sport. In 2005, a review of the available evidence on the psychometric properties of four computerized neuropsychological test batteries concluded that the tests did not possess the necessary criteria to warrant clinical application. Since the publication of that review, several more computerized neurocognitive tests have entered the market place. The purpose of this review is to summarize the body of published studies on psychometric properties and clinical utility of computerized neurocognitive tests available for use in the assessment of SRC. A review of the literature from 2005 to 2013 was conducted to gather evidence of test-retest reliability and clinical validity of these instruments. Reviewed articles included both prospective and retrospective studies of primarily sport-based adult and pediatric samples. Summaries are provided regarding the available evidence of reliability and validity for the most commonly used computerized neurocognitive tests in sports settings.

  11. Computerized Interpretation of Dynamic Breast MRI

    National Research Council Canada - National Science Library

    Chen, Weijie; Giger, Maryellen Lissak

    2005-01-01

    ... and prognosis of breast cancer. The research involves investigation of automatic methods for image artifacts correction, tumor segmentation, and extraction of computerized features that help distinguish between benign and malignant lesions...

  12. Analysis of internal and external validity criteria for a computerized visual search task: A pilot study.

    Science.gov (United States)

    Richard's, María M; Introzzi, Isabel; Zamora, Eliana; Vernucci, Santiago

    2017-01-01

    Inhibition is one of the main executive functions, because of its fundamental role in cognitive and social development. Given the importance of reliable and computerized measurements to assessment inhibitory performance, this research intends to analyze the internal and external criteria of validity of a computerized conjunction search task, to evaluate the role of perceptual inhibition. A sample of 41 children (21 females and 20 males), aged between 6 and 11 years old (M = 8.49, SD = 1.47), intentionally selected from a private management school of Mar del Plata (Argentina), middle socio-economic level were assessed. The Conjunction Search Task from the TAC Battery, Coding and Symbol Search tasks from Wechsler Intelligence Scale for Children were used. Overall, results allow us to confirm that the perceptual inhibition task form TAC presents solid rates of internal and external validity that make a valid measurement instrument of this process.

  13. Computerized access to materials data. A progress report

    International Nuclear Information System (INIS)

    Rumble, J. Jr.

    1985-01-01

    As the effort to build a comprehensive computerized materials data system grows, it becomes more obvious that the benefits will be far-reaching. During this workshop, the enthusiasm of the participants grew steadily until the questions became not''What,'' but ''When?''. The engineering community within the United States has banded together many times to advance progress in engineering capability. The computerized materials data system requires such an effort, and the rewards will be substantial. Chapter 3 identifies changes in the use of materials data in the Nuclear Power Industry. Chapter 4 describes the EPRI experience in building computerized materials databases. In Chapter 5, the National Materials Property Data Network is discussed. The next four chapters present summaries of the workshop discussions and its conclusions. Chapter 6 discusses the content of the proposed system, Chapter 7 its size and the data sources, and Chapter 8 the user interfaces and system capabilities. In Chapter 9, ways of making further progress are outlined

  14. Experience feedback of computerized controlled nuclear power plants

    International Nuclear Information System (INIS)

    Poizat, F.

    2004-01-01

    The N4 step of French PWR-type nuclear power plants is characterized by an instrumentation and control system entirely computerized (operation procedures including normal and accidental operation). Four power plants of this type (Chooz and Civaux sites) of 1450 MWe each were connected to the power grid between August 1996 and December 1999. The achievement of this program make it possible and necessary to carry out an experience feedback about the development, successes and difficulties encountered in order to draw out some lessons for future realizations. This is the aim of this article: 1 - usefulness and difficulties of such an experience feedback: evolution of instrumentation and control systems, necessary cautions; 2 - a successful computerized control: checking of systems operation, advantages, expectations; 3 - efficiency of computerized systems: demonstration of operation safety, profitability; 4 - conclusions and interrogations: system approach instead of 'micro-software' approach, commercial or 'made to measure' products, contract agreement with a supplier, when and how upgrading. (J.S.)

  15. Analysis of computed tomographic manifestations of primary lung cancer by histologic types

    International Nuclear Information System (INIS)

    Kim, Kyo Yeoun; Choe, Kyu Ok

    1988-01-01

    It is well known that primary lung cancer is one of the most common malignancies in Korea. With respect to the histologic type, primary lung carcinoma manifests itself in a number of different ways. The authors analyzed the computed tomographic (C-T) findings of 183 cases of pathologically confirmed primary lung cancer from 1983 to Aug. 1987 without prior information of histologic types. The results are as follows. 1. The distribution of histologic types of primary lung cancer was as follows: epidermoid carcinoma, 96 cases (52.5%); adenocarcinoma, 43 cases (23.5%); undifferentiated large cell carcinoma, 17 cases (9.2%) and undifferentiated small cell carcinoma, 27 cases (14.8%). 2. The male to female ratio was 3.9:1, the highest ratio occurring in undifferentiated small cell carcinoma 12.5:1 and the lowest ratio in adenocarcinoma 1.1:1 where there was no significant difference in the male to female ratio. 3. Chest computed tomographic findings by histologic type were as follows: (a) Epidermoid carcinoma (96 cases): The central type was the most prevalent (52 cases) with an incidence of 54%. Major air way obstruction was most frequently encountered in this type and was complete in 60% of the cases and partial in 25%. The incidence of cavitating malignancy was 10%, more common than other histologica types. (b) Adenocarcinoma (43 cases): The peripheral type was the most prevalent (28 cases) with an incidence of 63%. Lung to lung metastasis was 23%, more common than other histologic types. (c) Undifferentiated large cell carcinoma (17 cases): The highest incidence occurred in the peripheral type, 9 cases (53%). Chest wall involvement was 12%, more common than other histologic types. (d) Undifferentiated small cell carcinoma (27 cases): The central type (19 cases) presented the highest incidence (70%). Major air way obstruction was noted less severe than epidermoid carcinoma: complete 33%, partial 63%. The incidence of pericardial effusion and/or thickening was 18

  16. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  17. Self-masking noise subtraction (SMNS) in digital X-ray tomosynthesis for the improvement of tomographic image quality

    International Nuclear Information System (INIS)

    Oh, J.E.; Cho, H.S.; Choi, S.I.; Park, Y.O.; Lee, M.S.; Cho, H.M.; Yang, Y.J.; Je, U.K.; Woo, T.H.; Lee, H.K.

    2011-01-01

    In this paper, we proposed a simple and effective reconstruction algorithm, the so-called self-masking noise subtraction (SMNS), in digital X-ray tomosynthesis to reduce the tomographic blur that is inherent in the conventional tomosynthesis based upon the shift-and-add (SAA) method. Using the SAA and the SMNS algorithms, we investigated the influence of tomographic parameters such as tomographic angle (θ) and angle step (Δθ) on the image quality, measuring the signal-difference-to-noise ratio (SDNR). Our simulation results show that the proposed algorithm seems to be efficient in reducing the tomographic blur and, thus, improving image sharpness. We expect the simulation results to be useful for the optimal design of a digital X-ray tomosynthesis system for our ongoing application of nondestructive testing (NDT).

  18. Suitability of PCR fingerprinting, infrequent-restriction-site PCR, and pulsed-field gel electrophoresis, combined with computerized gel analysis, in library typing of Salmonella enterica serovar enteritidis

    DEFF Research Database (Denmark)

    Garaizar, J.; Lopez-Molina, N.; Laconcha, I.

    2000-01-01

    Strains of Salmonella enterica (n = 212) of different serovars and phage types were used to establish a library typing computerized system for serovar Enteritidis on the basis of PCR fingerprinting, infrequent-restriction-site PCR (IRS-PCR), or pulsed-field gel electrophoresis (PFGE). The rate...... showed an intercenter reproducibility value of 93.3%. The high reproducibility of PFGE combined with the previously determined high discrimination directed its use for library typing. The use of PFGE with enzymes XbaI, BlnI, and SpeI for library typing of serovar Enteritidis was assessed with GelCompar 4.......0 software, Three computer libraries of PFGE DNA profiles were constructed, and their ability to recognize new DNA profiles was analyzed. The results obtained pointed out that the combination of PFGE with computerized analysis could be suitable in long-term epidemiological comparison and surveillance...

  19. A gender-based analysis of high school athletes using computerized electrocardiogram measurements.

    Directory of Open Access Journals (Sweden)

    Nikhil Kumar

    Full Text Available BACKGROUND: The addition of the ECG to the preparticipation examination (PPE of high school athletes has been a topic for debate. Defining the difference between the high school male and female ECG is crucial to help initiate its implementation in the High School PPE. Establishing the different parameters set for the male and female ECG would help to reduce false positives. We examined the effect of gender on the high school athlete ECG by obtaining and analyzing ECG measurements of high school athletes from Henry M. Gunn High School. METHODS: In 2011 and 2012, computerized Electrocardiograms were recorded and analyzed on 181 athletes (52.5% male; mean age 16.1 ± 1.1 years who participated in 17 different sports. ECG statistics included intervals and durations in all 3 axes (X, Y, Z to calculate 12 lead voltage sums, QRS Amplitude, QT interval, QRS Duration, and the sum of the R wave in V5 and the S Wave in V2 (RS Sum. RESULTS: By computer analysis, we demonstrated that male athletes had significantly greater QRS duration, Q-wave duration, and T wave amplitude. (P<0.05. By contrast, female athletes had a significantly greater QTc interval. (P<0.05. CONCLUSION: The differences in ECG measurements in high school athletes are strongly associated with gender. However, body size does not correlate with the aforementioned ECG measurements. Our tables of the gender-specific parameters can help facilitate the development of a more large scale and in-depth ECG analysis for screening high school athletes in the future.

  20. DG TOMO: A new method for tomographic reconstruction

    International Nuclear Information System (INIS)

    Freitas, D. de; Feschet, F.; Cachin, F.; Geissler, B.; Bapt, A.; Karidioula, I.; Martin, C.; Kelly, A.; Mestas, D.; Gerard, Y.; Reveilles, J.P.; Maublant, J.

    2006-01-01

    Aim: FBP and OSEM are the most popular tomographic reconstruction methods in scintigraphy. FBP is a simple method but artifacts of reconstruction are generated which corrections induce degradation of the spatial resolution. OSEM takes account of statistical fluctuations but noise strongly increases after a certain number of iterations. We compare a new method of tomographic reconstruction based on discrete geometry (DG TOMO) to FBP and OSEM. Materials and methods: Acquisitions were performed on a three-head gamma-camera (Philips) with a NEMA Phantom containing six spheres of sizes from 10 to 37 mm inner diameter, filled with around 325 MBq/l of technetium-99 m. The spheres were positioned in water containing 3 MBq/l of technetium-99 m. Acquisitions were realized during a 180 o -rotation around the phantom by 25-s steps. DG TOMO has been developed in our laboratory in order to minimize the number of projections at acquisition. Two tomographic reconstructions utilizing 32 and 16 projections with FBP, OSEM and DG TOMO were performed and transverse slices were compared. Results: FBP with 32 projections detects only the activity in the three largest spheres (diameter ≥22 mm). With 16 projections, the star effect is predominant and the contrast of the third sphere is very low. OSEM with 32 projections provides a better image but the three smallest spheres (diameter ≤17 mm) are difficult to distinguish. With 16 projections, the three smaller spheres are not detectable. The results of DG TOMO are similar to OSEM. Conclusion: Since the parameters of DG TOMO can be further optimized, this method appears as a promising alternative for tomoscintigraphy reconstruction

  1. Computerized test versus personal interview as admission methods for graduate nursing studies: A retrospective cohort study.

    Science.gov (United States)

    Hazut, Koren; Romem, Pnina; Malkin, Smadar; Livshiz-Riven, Ilana

    2016-12-01

    The purpose of this study was to compare the predictive validity, economic efficiency, and faculty staff satisfaction of a computerized test versus a personal interview as admission methods for graduate nursing studies. A mixed method study was designed, including cross-sectional and retrospective cohorts, interviews, and cost analysis. One hundred and thirty-four students in the Master of Nursing program participated. The success of students in required core courses was similar in both admission method groups. The personal interview method was found to be a significant predictor of success, with cognitive variables the only significant contributors to the model. Higher satisfaction levels were reported with the computerized test compared with the personal interview method. The cost of the personal interview method, in annual hourly work, was 2.28 times higher than the computerized test. These findings may promote discussion regarding the cost benefit of the personal interview as an admission method for advanced academic studies in healthcare professions. © 2016 John Wiley & Sons Australia, Ltd.

  2. Computerized nursing process in the Intensive Care Unit: ergonomics and usability

    Directory of Open Access Journals (Sweden)

    Sônia Regina Wagner de Almeida

    Full Text Available Abstract OBJECTIVE Analyzing the ergonomics and usability criteria of the Computerized Nursing Process based on the International Classification for Nursing Practice in the Intensive Care Unit according to International Organization for Standardization(ISO. METHOD A quantitative, quasi-experimental, before-and-after study with a sample of 16 participants performed in an Intensive Care Unit. Data collection was performed through the application of five simulated clinical cases and an evaluation instrument. Data analysis was performed by descriptive and inferential statistics. RESULTS The organization, content and technical criteria were considered "excellent", and the interface criteria were considered "very good", obtaining means of 4.54, 4.60, 4.64 and 4.39, respectively. The analyzed standards obtained means above 4.0, being considered "very good" by the participants. CONCLUSION The Computerized Nursing Processmet ergonomic and usability standards according to the standards set by ISO. This technology supports nurses' clinical decision-making by providing complete and up-to-date content for Nursing practice in the Intensive Care Unit.

  3. Staging of bronchogenic carcinoma by computerized tomography

    International Nuclear Information System (INIS)

    Sommer, B.; Bauer, W.M.; Rath, M.; Fenzl, G.; Stelter, W.J.; Lissner, J.

    1981-01-01

    It was possible to check the information obtained by CT scanning in 36 patients out of 49 who had been subjected to computerized tomography, in respect of the extension of the primary tumour (T stage), and in 25 patients in respect of the degree of mediastinal lymphatic node involvement (N stage). In all 49 patients, the presence of bronchogenic carcinoma had been safely established. In 97% of the cases, assessment of the extension of the primary tumour was found to be correct. Assessment of the N stage, however, is more problematic, since detection of mediastinal lymphatic nodes by computerized tomography does not necessarily tell us something about their metastatic involvement. If all recognizable lymphatic nodes are interpreted as potential metastases, we have no false negative but 61% false positive results because of the frequency of postinflammatory or anthracotic lymphatic nodes. In case of exclusive assessment of lymphatic node enlargement above 1 cm diameter, the rate of metastatic nodes increases considerably (83%). Computerized tomography is definitely superior to all roentgenological methods in assessing the stage of a bronchogenic carcinoma; hence, it could occupy a key position in determining the diagnostic and therapeutic approach in patients with this disease. (orig.) [de

  4. 15 CFR 950.9 - Computerized Environmental Data and Information Retrieval Service.

    Science.gov (United States)

    2010-01-01

    ... Information Retrieval Service. 950.9 Section 950.9 Commerce and Foreign Trade Regulations Relating to Commerce... Computerized Environmental Data and Information Retrieval Service. The Environmental Data Index (ENDEX... computerized, information retrieval service provides a parallel subject-author-abstract referral service. A...

  5. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which is consisted of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for filed geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  6. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zhou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which consists of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for field geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  7. TomoBank: a tomographic data repository for computational x-ray science

    Science.gov (United States)

    De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.; Joost Batenburg, K.; Ludwig, Wolfgang; Mancini, Lucia; Marone, Federica; Mokso, Rajmund; Pelt, Daniël M.; Sijbers, Jan; Rivers, Mark

    2018-03-01

    There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology have made sub-second and multi-energy tomographic data collection possible (Gibbs et al 2015 Sci. Rep. 5 11824), but have also increased the demand to develop new reconstruction methods able to handle in situ (Pelt and Batenburg 2013 IEEE Trans. Image Process. 22 5238-51) and dynamic systems (Mohan et al 2015 IEEE Trans. Comput. Imaging 1 96-111) that can be quickly incorporated in beamline production software (Gürsoy et al 2014 J. Synchrotron Radiat. 21 1188-93). The x-ray tomography data bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging datasets and their descriptors.

  8. Tomographic Particle Image Velocimetry using Smartphones and Colored Shadows

    KAUST Repository

    Aguirre-Pablo, Andres A.; Alarfaj, Meshal K.; Li, Erqiang; Hernandez Sanchez, Jose Federico; Thoroddsen, Sigurdur T

    2017-01-01

    We demonstrate the viability of using four low-cost smartphone cameras to perform Tomographic PIV. We use colored shadows to imprint two or three different time-steps on the same image. The back-lighting is accomplished with three sets

  9. Formation of tomographic images with neutrons

    International Nuclear Information System (INIS)

    Duarte, A.; Tenreiro, C; Valencia, J; Steinman, G.; Henriquez, C

    2000-01-01

    The possibility of having a non-destructive method of analysis for archaeological and paleontological samples is of interest. A special group of fossil samples has come to our attention, which because of their value should be preserved and, therefore, the availability of an indirect, non-destructive, non contaminating analytical technique is important. The strong absorption of usual kinds of radiation by a fossilized sample restricts the application of conventional methods of analysis. A type of radiation that is not completely attenuated by thick samples, in sizes that are typical in paleontology, is necessary. Neutrons may be considered as an ideal non-invasive probe with the possibility of developing a technique for the formation and analysis of images. A technique has been developed for the spatial reconstruction of the contents of a fossilized sample (tomography) with neutrons, without touching or altering the sample in any way. The neutron beam was extracted from the RECH-1 reactor belonging to the CCHEN, La Reina. The tomographic images of the contents of a fossilized egg are presented for the first time and represent views or cuts of the content as well as a set that permits the three dimensional reconstruction of the inside of the object and its subsequent animation in graphic format. This project developed a technique for taking neutron radiographs of this kind of sample including the numerical algorithms and the treatment and formation of the images (CW)

  10. Accurately Diagnosing Uric Acid Stones from Conventional Computerized Tomography Imaging: Development and Preliminary Assessment of a Pixel Mapping Software.

    Science.gov (United States)

    Ganesan, Vishnu; De, Shubha; Shkumat, Nicholas; Marchini, Giovanni; Monga, Manoj

    2018-02-01

    Preoperative determination of uric acid stones from computerized tomography imaging would be of tremendous clinical use. We sought to design a software algorithm that could apply data from noncontrast computerized tomography to predict the presence of uric acid stones. Patients with pure uric acid and calcium oxalate stones were identified from our stone registry. Only stones greater than 4 mm which were clearly traceable from initial computerized tomography to final composition were included in analysis. A semiautomated computer algorithm was used to process image data. Average and maximum HU, eccentricity (deviation from a circle) and kurtosis (peakedness vs flatness) were automatically generated. These parameters were examined in several mathematical models to predict the presence of uric acid stones. A total of 100 patients, of whom 52 had calcium oxalate and 48 had uric acid stones, were included in the final analysis. Uric acid stones were significantly larger (12.2 vs 9.0 mm, p = 0.03) but calcium oxalate stones had higher mean attenuation (457 vs 315 HU, p = 0.001) and maximum attenuation (918 vs 553 HU, p uric acid stones. A combination of stone size, attenuation intensity and attenuation pattern from conventional computerized tomography can distinguish uric acid stones from calcium oxalate stones with high sensitivity and specificity. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Analysis of retinal nerve fibre layer changes in anisometropic amblyopia by Heidelberg retina tomograph

    International Nuclear Information System (INIS)

    Tayyab, A.; Afzal, F.

    2013-01-01

    Objective: To identify if anisometropic amblyopia is associated with changes in optic disk morphology. Methods: The study comprised a total of 80 eyes recruited from Shifa Foundation Community Health Centre and the Pakistan Institute of Medical Sciences, Islamabad between May and October 2012. Anisometropic amblyopia was the only cause of disability (visual acuity >6/12) in amblyopic eyes whereas normal eyes had a best corrected visual acuity of 6/6 and no morbidities. Patients with other causes of amblyopia, co-morbid ocular diseases, and in whom a good-quality image could not be obtained were excluded. Mean retinal nerve fiber layer thickness was analysed using Heidelberg retina tomograph. Analysis of frequency distribution, probability and regression were run on the data collected during the study using SPSS version 15.0. Results: The mean age of the patients was 23.85+-5.85 years. The retinal nerve fibre layer thickness ranged between 0.09mm and 0.35 mm (mean: 0.23mm+-0.07) in amblyopic eyes, and between 0.18mm and 0.36mm (mean: 0.25mm+-0.05) in normal eyes. The difference was not statistically significant (p=0.087). No association was found between the retinal nerve fiber layer thickness or the age and refractive error of patients. Conclusion: The optic disk does not appear to be the site of morphological changes in amblyopia. (author)

  12. Computerized tools in psychology: cross cultural and genetically informative studies of memory

    Directory of Open Access Journals (Sweden)

    Ismatullina V.

    2016-01-01

    Full Text Available In this article we presented the computerized tools for psychological studies of memory. The importance of implementing computerized automated tools for psychological studies is discussed. It has been shown that this tools can be used both for cross-cultural and genetically informative studies. The validity of these tools for cross-cultural and genetically informative studies of memory can be seen as the first step to use automated computerized tools for big data collection in psychology.

  13. Performance of confocal scanning laser tomograph Topographic Change Analysis (TCA) for assessing glaucomatous progression.

    Science.gov (United States)

    Bowd, Christopher; Balasubramanian, Madhusudhanan; Weinreb, Robert N; Vizzeri, Gianmarco; Alencar, Luciana M; O'Leary, Neil; Sample, Pamela A; Zangwill, Linda M

    2009-02-01

    To determine the sensitivity and specificity of confocal scanning laser ophthalmoscope's Topographic Change Analysis (TCA; Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany) parameters for discriminating between progressing glaucomatous and stable healthy eyes. The 0.90, 0.95, and 0.99 specificity cutoffs for various (n=70) TCA parameters were developed by using 1000 permuted topographic series derived from HRT images of 18 healthy eyes from Moorfields Eye Hospital, imaged at least four times. The cutoffs were then applied to topographic series from 36 eyes with known glaucomatous progression (by optic disc stereophotograph assessment and/or standard automated perimetry guided progression analysis, [GPA]) and 21 healthy eyes from the University of California, San Diego (UCSD) Diagnostic Innovations in Glaucoma Study (DIGS), all imaged at least four times, to determine TCA sensitivity and specificity. Cutoffs also were applied to 210 DIGS patients' eyes imaged at least four times with no evidence of progression (nonprogressed) by stereophotography or GPA. The TCA parameter providing the best sensitivity/specificity tradeoff using the 0.90, 0.95, and 0.99 cutoffs was the largest clustered superpixel area within the optic disc margin (CAREA(disc) mm(2)). Sensitivities/specificities for classifying progressing (by stereophotography and/or GPA) and healthy eyes were 0.778/0.809, 0.639/0.857, and 0.611/1.00, respectively. In nonprogressing eyes, specificities were 0.464, 0.570, and 0.647 (i.e., lower than in the healthy eyes). In addition, TCA parameter measurements of nonprogressing eyes were similar to those of progressing eyes. TCA parameters can discriminate between progressing and longitudinally observed healthy eyes. Low specificity in apparently nonprogressing patients' eyes suggests early progression detection using TCA.

  14. A detailed comparison of single-camera light-field PIV and tomographic PIV

    Science.gov (United States)

    Shi, Shengxian; Ding, Junfei; Atkinson, Callum; Soria, Julio; New, T. H.

    2018-03-01

    This paper conducts a comprehensive study between the single-camera light-field particle image velocimetry (LF-PIV) and the multi-camera tomographic particle image velocimetry (Tomo-PIV). Simulation studies were first performed using synthetic light-field and tomographic particle images, which extensively examine the difference between these two techniques by varying key parameters such as pixel to microlens ratio (PMR), light-field camera Tomo-camera pixel ratio (LTPR), particle seeding density and tomographic camera number. Simulation results indicate that the single LF-PIV can achieve accuracy consistent with that of multi-camera Tomo-PIV, but requires the use of overall greater number of pixels. Experimental studies were then conducted by simultaneously measuring low-speed jet flow with single-camera LF-PIV and four-camera Tomo-PIV systems. Experiments confirm that given a sufficiently high pixel resolution, a single-camera LF-PIV system can indeed deliver volumetric velocity field measurements for an equivalent field of view with a spatial resolution commensurate with those of multi-camera Tomo-PIV system, enabling accurate 3D measurements in applications where optical access is limited.

  15. IceBridge Radar L3 Tomographic Ice Thickness V001

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains Level-3 tomographic ice thickness measurements derived from data captured by the Center for Remote Sensing of Ice Sheets (CReSIS) Multichannel...

  16. Computerized tomography used in non-destructive testing of welded pipes

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, M; Rizescu, C; Georgescu, G; Marinescu, A; Chitescu, P; Sava, T; Neagu, M; Avram, D [Institute of Research and Design for Electrical Engineering, ICPE - Electrostatica Splaiul Unirii 313, Sect. 3, R-74204 Bucharest (Romania)

    1997-12-31

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using {gamma}-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or {gamma}-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: (1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., (2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs.

  17. Computerized tomography used in non-destructive testing of welded pipes

    International Nuclear Information System (INIS)

    Iovea, M.; Rizescu, C.; Georgescu, G.; Marinescu, A.; Chitescu, P.; Sava, T.; Neagu, M.; Avram, D.

    1996-01-01

    High quality standards in operation of National Power System is ensured by the use of high performance techniques and systems for Non-Destructive Testing (NDT). In recent years a number of new developments of the non-conventional technologies in the field of NDT have been achieved. In our laboratory there have been developed two computerized technologies using γ-ray computed tomography and ultrasonic imaging methods. The standard techniques for imaging from projection data is computerized tomography. The industrial computerized tomography methods consist in the measurement of thin X - or γ-ray beam attenuation when passing through some selected surface of the tested object, along several directions, so that by means of an adequate mathematical algorithm, a map of linear attenuation coefficients for the scanned surface is obtained. In fact, this map gives the density of materials occurring in the surface plane. Computerized tomography equipment, in various constructive versions, are intended for the following applications: 1) NDT in those fields requiring strict control of product quality, as for instance the nuclear energy, military industry, aeronautics, transportation fields, etc., 2) research in field of materials technology, machine engineering, metallurgy, welding, etc. This paper presents the applications of Computerized Tomography in NDT, by showing the results obtained on welded pipes, as well as the facilities offered by this method. In the final part, the paper presents the concept of a mobile tomography system for industrial pipes testing. (author). 2 figs., 7 refs

  18. Comparison of computerized tomography to sonography, applied in diseases of the pancreas

    International Nuclear Information System (INIS)

    Kluge, K.

    1982-01-01

    The examination results of 418 patients whose epigastria had been examined both by computerized tomography and sonography over 1 week in the time from beginning January 1978 until and of July 1979 were compared with regard to the imaging of the pancreas, reliability, and the specificity and sensitivity in establishing the diagnosis. For the sonographic examination, a compound and a real-time unit were used; the computerized tomography was carried out by means of an equipment of the 3rd generation with a scan time of 4 sec. The screening of the pancreas was significantly better using computerized tomography (99.3% US. 84% with US). As for accuracy, computerized tomography had 92.5% exact diagnoses versus 79.9% obtained by sonography. If, however, we look at the cases in which the pancreas could be screened with both methods the accuracy was almost the same (93.7 CT and 93.3% US). Specificity was almost of the same quality, however, the method of computerized tomography with 0.963 was slightly better than ultrasound with 0.943. As for sensitivity, sonography with 0.838 was better than CT with 0.721. The reason for that is the fact that a big part of the chronic pancreatites (30.3%) were not recognized by means of computerized tomography. (orig.) [de

  19. Computerizing marine biota: a rational approach

    Digital Repository Service at National Institute of Oceanography (India)

    Chavan, V.S.; Chandramohan, D.; Parulekar, A.H.

    Data on marine biota while being extensive are also patchy and scattered; thus making retrieval and dissemination of information time consuming. This emphasise the need for computerizing information on marine biota with the objective to collate...

  20. Computerized analysis of isometric tension studies provides important additional information about vasomotor activity

    Directory of Open Access Journals (Sweden)

    Vincent M.B.

    1997-01-01

    Full Text Available Concentration-response curves of isometric tension studies on isolated blood vessels are obtained traditionally. Although parameters such as Imax, EC50 and pA2 may be readily calculated, this method does not provide information on the temporal profile of the responses or the actual nature of the reaction curves. Computerized data acquisition systems can be used to obtain average data that represent a new source of otherwise inaccessible information, since early and late responses may be observed separately in detail

  1. Computerized Proof Techniques for Undergraduates

    Science.gov (United States)

    Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu

    2012-01-01

    The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete…

  2. A new algorithm for γ-ray tomographic imaging using a scintillation camera

    International Nuclear Information System (INIS)

    Terajima, Hirokatsu; Nakajima, Masato; Itoh, Takashi.

    1979-01-01

    The gamma ray tomographic imaging giving 3-dimensional distribution of RI in human bodies is being actively investigated for the reason that the conventional images are of 2-dimensional projection, but it is not yet employed practically, because there are some problems in the tomographic image quality obtained. One of the methods is a technique to determine the radioisotope distribution on each tomographic plane by placing a planar detector in parallel with the assumed tomographic planes and by processing the 2-dimensional radioisotope projection images thus obtained. It does not require the repetition of reconstructive algorithm. The authors have proposed the algorithm for this method, and have carried out the experiments to verify the propriety of the algorithm. Radioisotope phantom is composed of the overlapping acrylic cubic vessels of 30 mm sides containing radioisotopes arranged 2-dimensionally in each layer, and the multi-pinhole shutter array is used as the collimator. The projection image of radioisotope distribution on the scintillator face is converted into the digital imaging data sampled in 2-dimensional space of 64 x 64 with the mini-computer. Among the probable causes to affect the reconstructed image quality, statistical fluctuation, absorption of gamma ray and the shape of aperture for the collimator are discussed. These indicate that this method is more effective than the conventional methods, and can be the effective technique for medical diagnosis and therapy, because this is a technique to determine 3-dimensional distribution of RI by utilizing existing equipments. (Wakatsuki, Y.)

  3. Computerized tomographic evaluations of 37 cases of craniopharyngiomas

    International Nuclear Information System (INIS)

    Nagasawa, Shiro; Yamashita, Junkoh; Handa, Hajime; Takeuchi, Juji.

    1983-01-01

    Although craniopharyngiomas are well known to exhibit three basic CT characteristics: Calcification, cysts, and contrast enhancement (CE), several cases with atypical CT manifestations have been reported lately. These atypical manifestations can be classified into three groups: Unusual extensions of the tumors, high-density cysts, and marked homogeneous CE. The CT scans obtained in our recent series of 37 craniopharyngiomas were evaluated in an attempt to analyze the tumoral extensions, the cyst densities, and the CE, and were compared with those of other, rarer parasellar lesions. Cystic tumors were much more frequent than solid tumors (Table 1); 14 cases (38%) were exclusively cystic; 17 cases (46%), equally cystic and solid, and 6 cases (16%), solid. Calcifications were present in 86% of the children and 43% of the adults. Unusual extensions were noted in 7 cases (Fig. 1, 2): Anteriorly to the frontal fossa (5 cases, 14%), laterally to the temporal fossa (1 case, 3%), or posteriorly to the posterior fossa (1 case, 3%). All these tumors were either purely cystic or equally cystic and solid. Cystic portions were detected in the tumors of 31 cases (Table 2). Although the majority of the cystic portions (25 cases, 81%) were low in density, isodense cysts were observed in 6 cases (19%). Out of 23 cases exhibiting solid portions in the tumors, high-density areas (calcified masses) were detected in 3 cases and mixed-density areas in 20 cases. While these 20 cases all showed CE, marked homogeneous CE were noted in 5 cases (25%). (J.P.N.)

  4. An intragastric trichobezoar: computerised tomographic appearance.

    Directory of Open Access Journals (Sweden)

    Morris B

    2000-04-01

    Full Text Available A 26-year-old lady presented with a history of abdominal pain and distension since two months. The ultrasound examination showed an epigastric mass, which was delineated as a filling defect in the stomach on barium studies. The computerised tomographic scan showed a gastric mass with pockets of air in it, without post-contrast enhancement. This case highlights the characteristic appearance on computerised tomography of a bezoar within the stomach, a feature that is not commonly described in medical literature.

  5. Unusual uterine metastasis of invasive ductal carcinoma: A case report

    Directory of Open Access Journals (Sweden)

    Tayfur Çift

    2016-09-01

    Full Text Available Metastatic carcinoma of the uterus usually originates from other genital sites. Extragenital metastases such as breast are rare. A woman aged 34 years with a history of breast cancer was referred to the gynecology outpatient clinic for routine follow-up. Diagnostic tests and gynecologic examination revealed a uterine mass, which was removed with laparotomy. The pathologic investigation revealed metastasis of invasive lobular breast cancer. Chemotherapy was given and the patient has been under follow-up for 3 years with normal imaging on comput-erized tomographic examination and positron-emission tomography-computerized tomographic. It should be kept in mind that patients with breast cancer who have received tamoxifen may develop primary endometrial cancers, and may also demonstrate uterine metastases. With successful treatment these patients can obtain dis-ease-free survival.

  6. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    Directory of Open Access Journals (Sweden)

    Dengjiang Wang

    2016-11-01

    Full Text Available This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately.

  7. Computed tomographic evaluation of the altered pancreas in dog and cat

    International Nuclear Information System (INIS)

    Posch, B.

    2002-11-01

    Eighteen dogs and 12 cats of varying breed, age and sex underwent a computed tomographic study of the pancreas. Length, diameter and density of each lobe of the pancreas were measured. Further, the gained results were compared to the information established by the clinical examination, sonography, haematology and histology. Contrast CT improved evaluation of the pancreas in all cases of normal life controls. CT criteria such as changes in size, density, delimitation of the pancreas and the peripancreatic structures were analyzed. Increased pancreatic size was seen in inflammatory as well as in neoplastic diseases. There were no reliable computed tomographic criteria to differentiate pancreatic neoplasia from inflammation without peripancreatic findings. Ultrasonography proved to be a good screening method in this study: sonographic and computed tomographic results correlated in all cases with the exception of 5 cases. In contrast to ultrasonography CT could differentiate normal pancreas from pancreas atrophy. Computed tomography was superior to sonography in determining the full extent of pancreatic and peripancreatic signs due to the good overview and overall image of the abdominal structures. Serum chemistry of a- amylase and lipase were obtained in 28 animals. Assays of serum lipase and a- amylase activities were only able to detect acute pancreatitis in half of the canine cases. Despite morphological alterations detected with the help of sonography or CT, there were no significant increases in a- amylase and lipase in cats. Following computed tomography the pancreas of 10 animals was examined pathohistologically. With the exception of 2 cases the computed tomographic results correlated with the pathohistological findings. In conclusion, computed tomography (CT) proved to be a valuable method to evaluate the localization, the full extent and the seriousness of pancreatic lesions. (author)

  8. Imaging MOSS tomographic system for H-1NF

    International Nuclear Information System (INIS)

    Glass, F.; Howard, J.

    1999-01-01

    A tomographic diagnostic utilising the Modulated Optical Solid-State spectrometer (MOSS) is planned for the H-1NF stellarator at the ANU. It is designed to create two-dimensional temperature or velocity maps of a poloidal cross-section of the high temperature plasma of H-1NF. The introduction of the MOSS spectrometers has enabled the development of several diagnostics to be used on the H-1NF stellerator. The MOSS spectrometer allows calculations of the plasma temperature and bulk velocity based on a line-integrated measurement of light emitted from electronic transitions within the plasma. A tomographic system utilising a rotatable multi-view ring apparatus and spatial multiplexing through a MOSS spectrometer is currently being developed. The ring apparatus is placed inside the H-1NF vessel and encircles the plasma. Multiple line-of-sight views collect light through a poloidal cross-section of the plasma and the emitted light is coupled into large core optical fibres. The transmitted light, via the optical fibre bundle, is then imaged through a large aperture MOSS spectrometer and onto another optical fibre array. Each fibre is then fed into a photomultiplier tube for signal detection. Characterisation of the properties of the lithium niobate (LiNbO 3 ) crystal used for modulation in the MOSS spectrometer is being undertaken to account for ray divergence in the imaging system. Tomographic techniques enable the construction of a temperature or velocity map of the poloidal cross-section. Rotating the ring apparatus to a new viewing position for the next pulse of plasma should allow an accurate picture to be built up based on the reproducibility of the plasma pulses. It is expected that initial testing of the system will begin in May when H-1NF begins operations at 0.5 Telsa field strength

  9. Computerized materials protection, control, and accountability

    International Nuclear Information System (INIS)

    Whiteson, R.; Seitz, S.; Landry, R.P.; Hadden, M.L.; Painter, J.A.

    1997-01-01

    The proliferation of nuclear weapons, along with the technical knowledge and materials needed to make these weapons, is an enduring problem of international urgency. Current international nuclear nonproliferation efforts are aimed at deterring, detecting, and responding to proliferation of weapons of mass destruction. These safeguards efforts are being implemented by applying preeminent science and technology to the management and control of nuclear materials. By strengthening systems of nuclear material protection, control, and accountability (MPC and A), one can reduce the threat of nuclear weapons proliferation. Two major programs of international cooperation are now underway to achieve this goal. The first is between the US Department of Energy (DOE) and the Institutes of the Russian Federation (Laboratory-to-Laboratory Program), and the second is between the US Government and Governments of the former Soviet Republics (Government-to-Government Program). As part of these programs, the DOE is working with facilities to assist them in implementing computerized MPC and A systems. This work is a collaboration between computer scientists and safeguards experts in both the US and the new Republics. The US is making available technology and expertise to enable Russian experts to build on computerized MPC and A software developed in the US. This paper describes the joint efforts of these international teams to develop sophisticated computerized MPC and A systems using modern computer hardware and software technology. These systems are being customized to meet the site-specific needs of each facility

  10. Computerized plant maintenance management

    International Nuclear Information System (INIS)

    Kozusko, A.M.

    1986-01-01

    The evolution of the computer has and continues to have a great impact on industry. We are in an adjustment cycle with the current computer evolution, and will need to adapt to make the changes for the coming decade. Hardware and software are continually being enhanced. Computers are becoming more powerful and will eventually provide an effective man-machine interface. This paper shares experiences encountered during implementations of computerized maintenance systems

  11. On the feasibility of tomographic-PIV with low pulse energy illumination in a lifted turbulent jet flame

    Science.gov (United States)

    Boxx, I.; Carter, C. D.; Meier, W.

    2014-08-01

    Tomographic particle image velocimetry (tomographic-PIV) is a recently developed measurement technique used to acquire volumetric velocity field data in liquid and gaseous flows. The technique relies on line-of-sight reconstruction of the rays between a 3D particle distribution and a multi-camera imaging system. In a turbulent flame, however, index-of-refraction variations resulting from local heat-release may inhibit reconstruction and thereby render the technique infeasible. The objective of this study was to test the efficacy of tomographic-PIV in a turbulent flame. An additional goal was to determine the feasibility of acquiring usable tomographic-PIV measurements in a turbulent flame at multi-kHz acquisition rates with current-generation laser and camera technology. To this end, a setup consisting of four complementary metal oxide semiconductor cameras and a dual-cavity Nd:YAG laser was implemented to test the technique in a lifted turbulent jet flame. While the cameras were capable of kHz-rate image acquisition, the laser operated at a pulse repetition rate of only 10 Hz. However, use of this laser allowed exploration of the required pulse energy and thus power for a kHz-rate system. The imaged region was 29 × 28 × 2.7 mm in size. The tomographic reconstruction of the 3D particle distributions was accomplished using the multiplicative algebraic reconstruction technique. The results indicate that volumetric velocimetry via tomographic-PIV is feasible with pulse energies of 25 mJ, which is within the capability of current-generation kHz-rate diode-pumped solid-state lasers.

  12. NJP VOLUME 42 NO 2

    African Journals Online (AJOL)

    PROF. EZECHUKWU

    2015-01-07

    Jan 7, 2015 ... sciousness and subsequent right- ... 80/50mmHg (<50thcentile for gender, age and height), jugular venous pressure was ... Computerized Tomograph (CT) of the brain showed a large left hemispheric infarct. Subsequently,.

  13. Evaluation of computerized health management information system for primary health care in rural India

    Directory of Open Access Journals (Sweden)

    Singh Satyavir

    2010-11-01

    Full Text Available Abstract Background The Comprehensive Rural Health Services Project Ballabgarh, run by All India Institute of Medical Sciences (AIIMS, New Delhi has a computerized Health Management Information System (HMIS since 1988. The HMIS at Ballabgarh has undergone evolution and is currently in its third version which uses generic and open source software. This study was conducted to evaluate the effectiveness of a computerized Health Management Information System in rural health system in India. Methods The data for evaluation were collected by in-depth interviews of the stakeholders i.e. program managers (authors and health workers. Health Workers from AIIMS and Non-AIIMS Primary Health Centers were interviewed to compare the manual with computerized HMIS. A cost comparison between the two methods was carried out based on market costs. The resource utilization for both manual and computerized HMIS was identified based on workers' interviews. Results There have been no major hardware problems in use of computerized HMIS. More than 95% of data was found to be accurate. Health workers acknowledge the usefulness of HMIS in service delivery, data storage, generation of workplans and reports. For program managers, it provides a better tool for monitoring and supervision and data management. The initial cost incurred in computerization of two Primary Health Centers was estimated to be Indian National Rupee (INR 1674,217 (USD 35,622. Equivalent annual incremental cost of capital items was estimated as INR 198,017 (USD 4213. The annual savings is around INR 894,283 (USD 11,924. Conclusion The major advantage of computerization has been in saving of time of health workers in record keeping and report generation. The initial capital costs of computerization can be recovered within two years of implementation if the system is fully operational. Computerization has enabled implementation of a good system for service delivery, monitoring and supervision.

  14. Human factors analysis and design methods for nuclear waste retrieval systems. Volume III. User's guide for the computerized event-tree analysis technique

    International Nuclear Information System (INIS)

    Casey, S.M.; Deretsky, Z.

    1980-08-01

    This document provides detailed instructions for using the Computerized Event-Tree Analysis Technique (CETAT), a program designed to assist a human factors analyst in predicting event probabilities in complex man-machine configurations found in waste retrieval systems. The instructions contained herein describe how to (a) identify the scope of a CETAT analysis, (b) develop operator performance data, (c) enter an event-tree structure, (d) modify a data base, and (e) analyze event paths and man-machine system configurations. Designed to serve as a tool for developing, organizing, and analyzing operator-initiated event probabilities, CETAT simplifies the tasks of the experienced systems analyst by organizing large amounts of data and performing cumbersome and time consuming arithmetic calculations. The principal uses of CETAT in the waste retrieval development project will be to develop models of system reliability and evaluate alternative equipment designs and operator tasks. As with any automated technique, however, the value of the output will be a function of the knowledge and skill of the analyst using the program

  15. Mixed results in the safety performance of computerized physician order entry.

    Science.gov (United States)

    Metzger, Jane; Welebob, Emily; Bates, David W; Lipsitz, Stuart; Classen, David C

    2010-04-01

    Computerized physician order entry is a required feature for hospitals seeking to demonstrate meaningful use of electronic medical record systems and qualify for federal financial incentives. A national sample of sixty-two hospitals voluntarily used a simulation tool designed to assess how well safety decision support worked when applied to medication orders in computerized order entry. The simulation detected only 53 percent of the medication orders that would have resulted in fatalities and 10-82 percent of the test orders that would have caused serious adverse drug events. It is important to ascertain whether actual implementations of computerized physician order entry are achieving goals such as improved patient safety.

  16. Tomographic reconstruction by using FPSIRT (Fast Particle System Iterative Reconstruction Technique)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Icaro Valgueiro M.; Melo, Silvio de Barros; Dantas, Carlos; Lima, Emerson Alexandre; Silva, Ricardo Martins; Cardoso, Halisson Alberdan C., E-mail: ivmm@cin.ufpe.br, E-mail: sbm@cin.ufpe.br, E-mail: rmas@cin.ufpe.br, E-mail: hacc@cin.ufpe.br, E-mail: ccd@ufpe.br, E-mail: eal@cin.ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2015-07-01

    The PSIRT (Particle System Iterative Reconstruction Technique) is a method of tomographic image reconstruction primarily designed to work with configurations suitable for industrial applications. A particle system is an optimization technique inspired in real physical systems that associates to the reconstructing material a set of particles with certain physical features, subject to a force eld, which can produce movement. The system constantly updates the set of particles by repositioning them in such a way as to approach the equilibrium. The elastic potential along a trajectory is a function of the difference between the attenuation coefficient in the current configuration and the corresponding input data. PSIRT has been successfully used to reconstruct simulated and real objects subject to sets of parallel and fanbeam lines in different angles, representing typical gamma-ray tomographic arrangements. One of PSIRT's limitation was its performance, too slow for real time scenarios. In this work, it is presented a reformulation in PSIRT's computational model, which is able to grant the new algorithm, the FPSIRT - Fast System Iterative Reconstruction Technique, a performance up to 200-time faster than PSIRT's. In this work a comparison of their application to real and simulated data from the HSGT, High Speed Gamma Tomograph, is presented. (author)

  17. Tomographic reconstruction by using FPSIRT (Fast Particle System Iterative Reconstruction Technique)

    International Nuclear Information System (INIS)

    Moreira, Icaro Valgueiro M.; Melo, Silvio de Barros; Dantas, Carlos; Lima, Emerson Alexandre; Silva, Ricardo Martins; Cardoso, Halisson Alberdan C.

    2015-01-01

    The PSIRT (Particle System Iterative Reconstruction Technique) is a method of tomographic image reconstruction primarily designed to work with configurations suitable for industrial applications. A particle system is an optimization technique inspired in real physical systems that associates to the reconstructing material a set of particles with certain physical features, subject to a force eld, which can produce movement. The system constantly updates the set of particles by repositioning them in such a way as to approach the equilibrium. The elastic potential along a trajectory is a function of the difference between the attenuation coefficient in the current configuration and the corresponding input data. PSIRT has been successfully used to reconstruct simulated and real objects subject to sets of parallel and fanbeam lines in different angles, representing typical gamma-ray tomographic arrangements. One of PSIRT's limitation was its performance, too slow for real time scenarios. In this work, it is presented a reformulation in PSIRT's computational model, which is able to grant the new algorithm, the FPSIRT - Fast System Iterative Reconstruction Technique, a performance up to 200-time faster than PSIRT's. In this work a comparison of their application to real and simulated data from the HSGT, High Speed Gamma Tomograph, is presented. (author)

  18. The Impact of Computerization on Archival Finding Aids: A RAMP Study.

    Science.gov (United States)

    Kitching, Christopher

    This report is based on a questionnaire sent to 32 selected National Archives and on interviews with archivists from eight countries. Geared to the needs of developing countries, the report covers: (1) the impact of computerization on finding aids; (2) advantages and problems of computerization, including enhanced archival control, integration of…

  19. Computerized index for teaching files

    International Nuclear Information System (INIS)

    Bramble, J.M.

    1989-01-01

    A computerized index can be used to retrieve cases from a teaching file that have radiographic findings similar to an unknown case. The probability that a user will review cases with a correct diagnosis was estimated with use of radiographic findings of arthritis in hand radiographs of 110 cases from a teaching file. The nearest-neighbor classification algorithm was used as a computer index to 110 cases of arthritis. Each case was treated as an unknown and inputted to the computer index. The accuracy of the computer index in retrieving cases with the same diagnosis (including rheumatoid arthritis, gout, psoriatic arthritis, inflammatory osteoarthritis, and pyrophosphate arthropathy) was measured. A Bayes classifier algorithm was also tested on the same database. Results are presented. The nearest-neighbor algorithm was 83%. By comparison, the estimated accuracy of the Bayes classifier algorithm was 78%. Conclusions: A computerized index to a teaching file based on the nearest-neighbor algorithm should allow the user to review cases with the correct diagnosis of an unknown case, by entering the findings of the unknown case

  20. DOE transporation programs - computerized techniques

    Energy Technology Data Exchange (ETDEWEB)

    Joy, D.S.; Johnson, P.E.; Fore, C.S.; Peterson, B.E.

    1983-01-01

    One of the major thrusts of the transportation programs at the Oak Ridge National Laboratory has been the development of a number of computerized transportation programs and data bases. The U.S. Department of Energy (DOE) is supporting these efforts through the Transportation Technology Center at Sandia National Laboratories and the Tranportation Operations and Traffic Management (TOTM) organization at DOE Headquarters. Initially this project was centered upon research activities. However, since these tools provide traffic managers and key personnel involved in preshipment planning with a unique resource for ensuring that the movement of radioactive materials can be properly accomplished, additional interest and support is coming from the operational side of DOE. The major accomplishments include the development of two routing models (one for rail shipments and the other for highway shipments), an emergency response assistance program, and two data bases containing pertinent legislative and regulatory information. This paper discusses the mose recent advances in, and additions to, these computerized techniques and provides examples of how they are used.

  1. Effective Heart Disease Detection Based on Quantitative Computerized Traditional Chinese Medicine Using Representation Based Classifiers

    Directory of Open Access Journals (Sweden)

    Ting Shu

    2017-01-01

    Full Text Available At present, heart disease is the number one cause of death worldwide. Traditionally, heart disease is commonly detected using blood tests, electrocardiogram, cardiac computerized tomography scan, cardiac magnetic resonance imaging, and so on. However, these traditional diagnostic methods are time consuming and/or invasive. In this paper, we propose an effective noninvasive computerized method based on facial images to quantitatively detect heart disease. Specifically, facial key block color features are extracted from facial images and analyzed using the Probabilistic Collaborative Representation Based Classifier. The idea of facial key block color analysis is founded in Traditional Chinese Medicine. A new dataset consisting of 581 heart disease and 581 healthy samples was experimented by the proposed method. In order to optimize the Probabilistic Collaborative Representation Based Classifier, an analysis of its parameters was performed. According to the experimental results, the proposed method obtains the highest accuracy compared with other classifiers and is proven to be effective at heart disease detection.

  2. Computed tomographic determination of tracheal dimensions in children and adolescents

    International Nuclear Information System (INIS)

    Griscom, N.T.

    1982-01-01

    A computed tomographic system for determining the internal diameters, cross-sectional area, and length of the trachea in children and adolescents was developed. Intraluminal volumes were calculated from these measurements.The results of 18 analyses are reported

  3. Role of computerized tomography in diagnosis of atypical gall bladder and common bile duct stones

    International Nuclear Information System (INIS)

    El-Husseni, Tareq K.; Al-Shebrein, Ibrahim A.

    2001-01-01

    Objective was to assess the value of computerized tomography as an adjuvant to ultrasound in the diagnosis of atypical gallbladder and common duct stone disease. Real time ultrasound scanning for the gallbladder and common duct was performed in the routine manner. High resolution computerized tomography images were subsequently obtained for the region of interest. Computerized tomography resolved undetermined results as follows: 1. Non shadowing gallbladder debris (6 points), 2. Focal gallbladder wall thickening (2 points), 3. Stone obscured by calcified gallbladder wall (3 points), 4. Non visualized gallbladder double arc shadow (4 points), 5 and 6. Impacted gallbladder neck and common duct stones (18 points), computerized tomography gave false positive diagnosis in (2 points). Computerized tomography provided an effective and reliable means for the diagnosis of atypical gallbladder calculi when ultrasound was imprecise or the findings contradicted the clinical presentation. Finally if gallbladder neck or common duct stones are suspected, in addition to computerized tomography other imaging techniques such as magnetic resonance cholangio pancreatography or endoscopic retrograde cholangiopancreatography in addition to computerized tomography may be needed to avoid false positive diagnosis prior to surgery. (author)

  4. Tomographic anthropomorphic models. Pt. 1

    International Nuclear Information System (INIS)

    Veit, R.; Zankl, M.; Petoussi, N.; Mannweiler, E.; Drexler, G.; Williams, G.

    1989-01-01

    The first generation of heterogenoeous anthropomorphic mathematical models to be used in dose calculations was the MIRD-5 adult phantom, followed by the pediatric MIRD-type phantoms and by the GSF sex-specific phantoms ADAM and EVA. A new generation of realistic anthropomorphic models is now introduced. The organs and tissues of these models consist of a well defined number of volume elements (voxels), derived from computer tomographic (CT) data; consequently, these models were named voxel or tomographic models. So far two voxel models of real patients are available: one of an 8 week old baby and of a 7 year old child. For simplicity, the model of the baby will be referred to as BABY and that of the child as CHILD. In chapter 1 a brief literature review is given on the existing mathematical models and their applications. The reasons that lead to the construction of the new CT models is discussed. In chapter 2 the technique is described which allows to convert any physical object into computer files to be used for dose calculations. The technique which produces three dimensional reconstructions of high resolution is discussed. In chapter 3 the main characteristics of the models of the baby and child are given. Tables of organ masses and volumes are presented together with three dimensional images of some organs and tissues. A special mention is given to the assessment of bone marrow distribution. Chapter 4 gives a short description of the Monte Carlo code used in conjunction with the models to calculate organ and tissue doses resulting from photon exposures. Some technical details concerning the computer files which describe the models are also given. (orig./HP)

  5. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  6. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  7. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  8. Computerized tomography of kidneys in long-term dialysis patients

    International Nuclear Information System (INIS)

    Srp, A.; Merta, M.; Sulkova, S.

    1990-01-01

    A cohort is presented of 21 patients with irreversible kidney failure who were examined by computerized tomography in 1986-1987. The mean period of dialysis programme was 5.7 years, chronic glomerulonephritis and interstitial nephritis were the basic conditions. According to the results of computerized tomography, the patients were divided into four groups: 1. the presence of cysts or tumors was not established, 2. multiplecysts were found in bilateral location, 3. less than 3 cysts were found, 4. kidney tumor was diagnosed. The factor causing the development of the cysts was not identified. It is presumed that the disease is caused by a biologically active substance which is not efficiently dialyzed. The examination of the kidneys is recommended in patients in the stage of chronic kidney insufficiency and particularly in patients on dialysis for a long period of time. The recommended examination uses computerized tomography, and attention should be given to the possible occurence of acquired cystic disease or kidney tumors. (author). 6 figs., 8 refs

  9. Experimental studies of computerized procedures and team size in nuclear power plant operations

    International Nuclear Information System (INIS)

    Huang, F.-H.; Hwang, S.-L.

    2009-01-01

    The operation of a nuclear power plant is so complex that it requires teamwork. To support team performance, a system need to provide all team members integrated information displays as well as decision aids (e.g., computerized procedures). Two experiments were conducted to investigate the effects of computerized procedures and team size on operating performance. Forty-five participants were involved in the experiments. Each participant executed decision and action tasks to deal with alarm signals, while detecting occasional system errors in the interface. Results showed that effects of computerized procedures were significant on various performance indicators, such as operation time, operation errors, and learning effect, and that two operators would be a satisfactory size in the teamwork system providing computerized procedures

  10. Ovarian metastases: Computed tomographic appearances

    International Nuclear Information System (INIS)

    Megibow, A.J.; Hulnick, D.H.; Bosniak, M.A.; Balthazar, E.J.

    1985-01-01

    Computed tomographic scans of 34 patients with ovarian metastases were reviewed to assess the radiographic appearances and to correlate these with the primary neoplasms. Primary neoplasms were located in the colon (20 patients), breast (six), stomach (five), small bowel (one), bladder (one), and Wilms tumor of the kidney (one). The radiographic appearance of the metastatic lesions could be described as predominantly cystic (14 lesions), mixed (12 lesions), or solid (seven lesions). The cystic and mixed lesions tended to be larger in overall diameter than the solid. The metastases from gastric carcinoma appeared solid in four of five cases. The metastases from the other neoplasms had variable appearances simulating primary ovarian carcinoma

  11. A computerized legal information management system | Ohiagu ...

    African Journals Online (AJOL)

    A computerized legal information management system. ... process through the filling system using the survey research methodology. ... A framework for the design and implementation of a legal information management system was presented.

  12. KiDS-450: tomographic cross-correlation of galaxy shear with Planck lensing

    Science.gov (United States)

    Harnois-Déraps, Joachim; Tröster, Tilman; Chisari, Nora Elisa; Heymans, Catherine; van Waerbeke, Ludovic; Asgari, Marika; Bilicki, Maciej; Choi, Ami; Erben, Thomas; Hildebrandt, Hendrik; Hoekstra, Henk; Joudaki, Shahab; Kuijken, Konrad; Merten, Julian; Miller, Lance; Robertson, Naomi; Schneider, Peter; Viola, Massimo

    2017-10-01

    We present the tomographic cross-correlation between galaxy lensing measured in the Kilo Degree Survey (KiDS-450) with overlapping lensing measurements of the cosmic microwave background (CMB), as detected by Planck 2015. We compare our joint probe measurement to the theoretical expectation for a flat Λ cold dark matter cosmology, assuming the best-fitting cosmological parameters from the KiDS-450 cosmic shear and Planck CMB analyses. We find that our results are consistent within 1σ with the KiDS-450 cosmology, with an amplitude re-scaling parameter AKiDS = 0.86 ± 0.19. Adopting a Planck cosmology, we find our results are consistent within 2σ, with APlanck = 0.68 ± 0.15. We show that the agreement is improved in both cases when the contamination to the signal by intrinsic galaxy alignments is accounted for, increasing A by ∼0.1. This is the first tomographic analysis of the galaxy lensing - CMB lensing cross-correlation signal, and is based on five photometric redshift bins. We use this measurement as an independent validation of the multiplicative shear calibration and of the calibrated source redshift distribution at high redshifts. We find that constraints on these two quantities are strongly correlated when obtained from this technique, which should therefore not be considered as a stand-alone competitive calibration tool.

  13. Design and construction of the gamma ray transmission tomographer g-TAC-02

    International Nuclear Information System (INIS)

    Pavon Hernandez, Noriel; Ravelo Sanchez, Alberto; Idel, Pedro; Macias Perez, Rafael; Garcia Trapaga, Cesar; Campos Montenegro, Augusto

    2000-01-01

    An equipment for gamma ray transmission tomographer was designed and constructed in the Higher Institute of Nuclear Sciences and Technology. It was the g-TAC-01, based on a nuclear instrumentation, a mechanic instrumentation, and the control of the system from a personal computer. This first version permitted to obtain the know how of the technology of construction of equipment for tomography. The present work describes the second version of the gamma ray transmission tomographer: the g-TAC-02, with very important upgrading in the control session. Now the control system is a microcontroller based, electronic control system, designed to work in multiples forms: manual, automatic and with the computer

  14. Tomographic scanning apparatus with ionization detector means

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus using a fan beam and digital output signal. Particular reference is made to the gas-pressurized ionization detector chamber, consisting of an array of side-by-side elongate ionization detection cells, the principal axis of each of the said cells being oriented along a radius extending towards the radiation source, and connection means for applying potentials across the cells for taking their output signals. (U.K.)

  15. A review of US anthropometric reference data (1971-2000) with comparisons to both stylized and tomographic anatomic models

    International Nuclear Information System (INIS)

    Huh, C; Bolch, W E

    2003-01-01

    Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within ∼5%), present-day 40-year-old males have an average total body mass that is ∼16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males

  16. Tomographic multiphase flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Saetre, C., E-mail: camilla@ift.uib.no [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Johansen, G.A. [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Tjugum, S.A. [Michelsen Centre for Industrial Measurement Science and Technology (Norway); Roxar Flow Measurement, Bergen (Norway)

    2012-07-15

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: Black-Right-Pointing-Pointer Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. Black-Right-Pointing-Pointer High-speed gamma ray tomograph as reference for the flow

  17. Tomographic multiphase flow measurement

    International Nuclear Information System (INIS)

    Sætre, C.; Johansen, G.A.; Tjugum, S.A.

    2012-01-01

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: ► Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. ► High-speed gamma ray tomograph as reference for the flow pattern and gas fraction. ► Dual modality

  18. The Development of CPSES Plug-in(CPMP) for APR1400 Computerized Procedure Effective Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Seong, No Kyu; Park, Jin Kyun; Jung, Yeon Sub [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The Computerized Procedure System (CPS) is one of the Man Machine Interface (MMI) resources of the Shin-Kori 3 and 4 nuclear power plants. The CPS is a computerized operator support system that enables operating crew to execute procedures in an accurate and fast manner. The Computerized Procedure (CP) is the XML data file in executable format that can be installed in the Procedure eXecution System (PXS) for execution. The CP contains specific information related to a particular procedure (i.e. LOCA). These computerized procedures such as Alarm Response Procedures (ARP) are separated into individual alarm procedure to maximize function interface between CPS and DCS. E.g. 'Procedure open by alarm list'. The procedure writer's burden to manage many procedures has been increased because of separated procedures. This paper introduces Computerized Procedure System Engineering System (CPSES) plug-in that is computerized procedure management program (CPMP) to reduce procedure writer's burden. This paper introduces the main features of CPMP. CPMP reduces procedure writer's or CPX maintainer's burden. This program is implemented and tested by program design requirement.

  19. Review of trends in computerized systems for operator support

    International Nuclear Information System (INIS)

    Cain, D.G.

    1985-01-01

    The major trends shaping the development of computerized operator support systems in nuclear power plants are reviewed. These trends are the result of prior research in disturbance analysis systems that provided the technology base, and the SPDS requirement, which has been the impetus for change. The process is expected to result in hybrid control rooms with computer-driven supervisory workstations that complement conventional control board lay-outs. In the next three to five year period substantial upgrading of computer hardware will allow new and more sophisticated applications routines to be developed for operator support. Greater attention is being given to on-line validation of input signals for computer applications. A general movement towards operating strategies that are not based upon pre-analyzed event sequences is expected to influence the development of operator aids. The integration of displays with operating procedures will enable the computer system to a better coupling between problem detection and its resolution. Improved design methodology will assure that computer applications are accepted and used by operations personnel. Greater on-line analysis capability is stimulating the trend towards more on-site analysis and decision-making at nuclear power plants. Software standardization reflects the high cost of software development and the desire by utilities to gain greater independence from suppliers. There is growing realization that control rooms are beset by many of the demands and limitations of other office settings and that some of these may be addressed by the burgeoning office automation technology. Trends beyond the next five years are difficult to predict; however, there will be a trend towards more intelligent software. Artificial intelligence technology may play a pivotal role in future applications. Taking these trends into perspective, the author concludes that a promising future exists for computerized operator support in nuclear

  20. Process and installation for producing tomographic images of the distribution of a radiotracer

    International Nuclear Information System (INIS)

    Fonroget, Jacques; Brunol, Jean.

    1977-01-01

    The invention particularly concerns a process for obtaining tomographic images of an object formed by a radiotracer distributed spacially over three dimensions. This process, using a detection device with an appreciably plane detection surface and at least one collimation orifice provided in a partition between the detection surface and the object, enables tomographic sections to be obtained with an excellent three-dimensional resolution of the images achieved. It is employed to advantage in an installation that includes a detection device or gamma camera on an appreciably plane surface, a device having a series of collimation apertures which may be used in succession, these holes being appreciably distributed over a common plane parallel to the detection surface, and a holder for the object. This holder can be moved in appreciably parallel translation to the common plane. The aim of this invention is, inter alia, to meet two requirements: localization in space and obtaining good contrasts. This aim is achieved by the fact that at least one tomographic image is obtained from a series of intermediate images of the object [fr

  1. Computerizing Maintenance Management Improves School Processes.

    Science.gov (United States)

    Conroy, Pat

    2002-01-01

    Describes how a Computerized Maintenance Management System (CMMS), a centralized maintenance operations database that facilitates work order procedures and staff directives, can help individual school campuses and school districts to manage maintenance. Presents the benefits of CMMS and things to consider in CMMS selection. (EV)

  2. Computerized comprehensive data analysis of Lung Imaging Database Consortium (LIDC)

    International Nuclear Information System (INIS)

    Tan Jun; Pu Jiantao; Zheng Bin; Wang Xingwei; Leader, Joseph K.

    2010-01-01

    Purpose: Lung Image Database Consortium (LIDC) is the largest public CT image database of lung nodules. In this study, the authors present a comprehensive and the most updated analysis of this dynamically growing database under the help of a computerized tool, aiming to assist researchers to optimally use this database for lung cancer related investigations. Methods: The authors developed a computer scheme to automatically match the nodule outlines marked manually by radiologists on CT images. A large variety of characteristics regarding the annotated nodules in the database including volume, spiculation level, elongation, interobserver variability, as well as the intersection of delineated nodule voxels and overlapping ratio between the same nodules marked by different radiologists are automatically calculated and summarized. The scheme was applied to analyze all 157 examinations with complete annotation data currently available in LIDC dataset. Results: The scheme summarizes the statistical distributions of the abovementioned geometric and diagnosis features. Among the 391 nodules, (1) 365 (93.35%) have principal axis length ≤20 mm; (2) 120, 75, 76, and 120 were marked by one, two, three, and four radiologists, respectively; and (3) 122 (32.48%) have the maximum volume overlapping ratios ≥80% for the delineations of two radiologists, while 198 (50.64%) have the maximum volume overlapping ratios <60%. The results also showed that 72.89% of the nodules were assessed with malignancy score between 2 and 4, and only 7.93% of these nodules were considered as severely malignant (malignancy ≥4). Conclusions: This study demonstrates that LIDC contains examinations covering a diverse distribution of nodule characteristics and it can be a useful resource to assess the performance of the nodule detection and/or segmentation schemes.

  3. Case of neurosarcoidosis monitored by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T; Kimura, M; Komai, T; Yamamoto, S; Yamamura, I [Kanazawa Univ. (Japan). School of Medicine

    1979-12-01

    A 21-year-old man complaining of impaired visual acuity was admitted to the hospital. Physical examinations showed asymptomatic bilateral hilar lymphadenopathy and cardiomyopathy. Neurological findings disclosed left blindness and right temporal hemianopsia. Computerized tomography, pneumoencephalography and carotid angiography revealed a suprasellar mass. After the admission, the following symptoms deteriorated rapidly: diabetes insipidus, anterior pituitary dysfunction, visual loss of the right eye and hepatomegaly, subsequently consciousness disorder developed during a month though he was given steroids. The more deteriorated the clinical course, the larger the suprasellar mass with expanding hydrocephalus in repeated computerized tomographies. After the ventriculo-peritoneal shunt operation, consciousness improved. Diabetes insipidus also improved after Diabenese administration. On the operation, adhesive arachnoiditis over all the frontotemporal cortex and swollen purplishly red optic chiasm were exposed. Microscopically the specimen from the optic chiasm evidenced a sarcoid granuloma which composed of epitheroid cells, lymphocytes and multi-nucleated giant cells with numerous hemosiderin droplets. The specimen from the surface of the left frontal lobe showed thick fibrosis in the subarachnoid space. By steroids therapy, diabetes insipidus and hepatomegaly disappeared five months after the admission, whereas blindness never recovered. He died of developed status epilepticus eleven months after the admission. The authors reviewed neuroradiological findings of neurocarcoidosis based on pathological findings in the literature, and emphasized that computerized tomography was the most useful for diagnosis and treatment of neurosarcoidosis.

  4. Reading Comprehension: A Computerized Intervention with Primary-age Poor Readers.

    Science.gov (United States)

    Horne, Joanna Kathryn

    2017-05-01

    The current study investigates the effectiveness of a computerized reading comprehension programme on the reading accuracy, reading comprehension and reading rate of primary-age poor readers. There is little published literature relating to computerized reading interventions in UK primary schools, and no previous studies have investigated the Comprehension Booster programme. Thirty-eight children (26 boys and 12 girls; aged 6:7 to 11:0) from two schools in East Yorkshire, UK, took part. Half of the participants (the intervention group) undertook the Comprehension Booster programme for a 6-week period, whilst the other half (the control group) continued with their usual teaching. Significant effects of the intervention were found, with increases in reading accuracy and reading comprehension for the intervention group. It is concluded that computerized reading programmes can be effective in improving reading skills, and these are particularly useful for pupils with reading difficulties in disadvantaged areas, where resources are limited and family support in reading is lower. However, such programmes are not a replacement for good teaching, and regular monitoring of children with reading difficulties is required. Further research is necessary to compare the programme used here to other conventional and computerized intervention programmes, using a larger sample. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Thrombin effectuates therapeutic arteriogenesis in the rabbit hindlimb ischemia model: A quantitative analysis by computerized in vivo imaging

    International Nuclear Information System (INIS)

    Kagadis, George C.; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Diamantopoulos, Athanassios; Samaras, Nikolaos; Maroulis, John; Siablis, Dimitrios; Nikiforidis, George C.

    2006-01-01

    We report on an experimental mammalian controlled study that documents arteriogenic capacity of thrombin and utilizes computerized algorithms to quantify the newly formed vessels. Hindlimb ischemia was surgically invoked in 10 New Zealand white rabbits. After quiescence of endogenous angiogenesis heterologous bovine thrombin was intramuscularly injected (1500 units) in one hindlimb per rabbit (Group T). Contralateral limbs were infused with normal saline (Group C). Digital subtraction angiography (DSA) of both limbs was performed after thrombin infusion by selective cannulation of the abdominal aorta and digital images were post-processed with computerized algorithms in order to enhance newly formed vessels. Total vessel area and total vessel length were quantified. In vivo functional evaluation included measurements of blood flow volume at the level of the external iliac artery by Doppler ultrasonography both at baseline and at 20 days after thrombin infusion. Total vessel area and length (in pixels) were 14,713+/-1023 and 5466+/-1327 in group T versus 12,015+/-2557 and 4598+/-1269 in group C (p=0.0062 and 0.1526, respectively). Blood flow volumes (ml/min) at baseline and at 20 days after thrombin infusion were 25.87+/-11.09 and 38.06+/-11.72 in group T versus 26.57+/-11.19 and 20.35+/-7.20 in group C (p=0.8898 and 0.0007, respectively). Intramuscular thrombin effectuates an arteriogenic response in the rabbit hindlimb ischemia model. Computerized algorithms may enable accurate quantification of the neovascularization outcome

  6. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single-shot, volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...acquisition; (110.6955) Tomographic imaging ; (110.6960) Tomography; (280.2490) Flow diagnostics; (300.2530) Fluorescence , laser-induced...84 (1983). 2. I. van Cruyningen, A. Lozano, and R. K. Hanson, “Quantitative imaging of concentration by planar laser-induced fluorescence ,” Exp

  7. Ratios between effective doses for tomographic and mathematician models due to internal exposure of photons

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Khoury, H.J.; Santos, A.M.; Loureiro, E.C.M.

    2005-01-01

    The development of new and sophisticated Monte Carlo codes and tomographic human phantoms or voxels motivated the International Commission on Radiological Protection (ICRP) to revise the traditional models of exposure, which have been used to calculate effective dose coefficients for organs and tissues based on mathematician phantoms known as MIRD5. This paper shows the results of calculations using tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed by the authors as well as with the phantoms ADAM and EVA, of specific genres, type MIRD5, coupled to the EGS4 Monte Carlo and MCNP4C codes, for internal exposure with photons of energies between 10 keV and 4 MeV to several organs sources. Effective Doses for both models, tomographic and mathematician, will be compared separately as a function of the Monte Carlo code replacement, of compositions of human tissues and the anatomy reproduced through tomographs. The results indicate that for photon internal exposure, the use of models of exposure based in voxel, increases the values of effective doses up to 70% for some organs sources considered in this study, when compared with the corresponding results obtained with phantoms of MIRD-5 type

  8. Quantum-tomographic cryptography with a semiconductor single-photon source

    International Nuclear Information System (INIS)

    Kaszlikowski, D.; Yang, L.J.; Yong, L.S.; Willeboordse, F.H.; Kwek, L.C.

    2005-01-01

    We analyze the security of so-called quantum-tomographic cryptography with the source producing entangled photons via an experimental scheme proposed by Fattal et al. [Phys. Rev. Lett. 92, 37903 (2004)]. We determine the range of the experimental parameters for which the protocol is secure against the most general incoherent attacks

  9. Computerized data treatment technology

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Maddox, J.H.; Wren, H.F.

    1977-01-01

    The Savannah River Laboratory (SRL) has accepted responsibility for a hydrogeochemical and stream-sediment reconnaissance in 25 eastern states as part of the National Uranium Resource Evaluation (NURE). SRL has developed a computerized program for recording, processing, updating, retrieving, and analyzing hydrogeochemical data from this reconnaissance. This program will handle an expected 150 million bytes of hydrogeochemical data from 150,000 to 200,000 sample sites over the next four years. The SRL--NURE hydrogeochemical data management system is written in FORTRAN IV for an IBM System 360/195 computer and is designed to easily accommodate changes in types of collected data and input format. As the data become available, they are accepted and combined with relevant data already in the system. SRL also developed a sample inventory and control system and a graphics and analysis system. The sample inventory and control system accounts for the movements of all samples and forms from initial receipt through final storage. Approximately six million sample movements are expected. The graphics and analysis system provides easily usable programs for reporting and interpreting data. Because of the large volume of data to be interpreted, the graphics and analysis system plays a central role in the hydrogeochemical program. Programs developed to provide two- and three-dimensional plots of sampled geographic areas show concentrations and locations of individual variables which are displayed and reproduced photographically. Pattern recognition techniques are also available, and they allow multivariate data to be categorized into ''clusters,'' which may indicate sites favorable for uranium exploration

  10. Recurrent lymph node metastases after craniocervical tumours: Computerized tomography

    International Nuclear Information System (INIS)

    Helmberger, H.; Lenz, M.; Kersting-Sommerhoff, B.; Bautz, W.; Kretz, S.

    1992-01-01

    A total of 544 CT examinations of the craniocervical region carried out in 231 patients were analyzed on a retrospective basis in order to assess the clinical value of contrast-enhanced computerized tomography, being carried out either for comparison with or in combination with clinical control examinations, in the post-therapeutic surveillance of patients treated for craniocervical tumours. The diagnostic accuracy attained with computerized tomography in the detection of recurrent lymph node metastases was 95% and thus superior to that determined for clinical control examinations (80%). (orig./GDG) [de

  11. Density evaluation by computerized tomography in plain soils over different manipulation systems

    International Nuclear Information System (INIS)

    Pedrotti, Alceu

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic

  12. The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

    Science.gov (United States)

    Strauss, G H; Stanford, W L; Berkowitz, S J

    1989-03-01

    We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

  13. Morphometric analysis of erythrocytes from patients with thalassemia using tomographic diffractive microscopy

    Science.gov (United States)

    Lin, Yang-Hsien; Huang, Shin-Shyang; Wu, Shang-Ju; Sung, Kung-Bin

    2017-11-01

    Complete blood count is the most common test to detect anemia, but it is unable to obtain the abnormal shape of erythrocytes, which highly correlates with the hematologic function. Tomographic diffractive microscopy (TDM) is an emerging technique capable of quantifying three-dimensional (3-D) refractive index (RI) distributions of erythrocytes without labeling. TDM was used to characterize optical and morphological properties of 172 erythrocytes from healthy volunteers and 419 erythrocytes from thalassemic patients. To efficiently extract and analyze the properties of erythrocytes, we developed an adaptive region-growing method for automatically delineating erythrocytes from 3-D RI maps. The thalassemic erythrocytes not only contained lower hemoglobin content but also showed doughnut shape and significantly lower volume, surface area, effective radius, and average thickness. A multi-indices prediction model achieved perfect accuracy of diagnosing thalassemia using four features, including the optical volume, surface-area-to-volume ratio, sphericity index, and surface area. The results demonstrate the ability of TDM to provide quantitative, hematologic measurements and to assess morphological features of erythrocytes to distinguish healthy and thalassemic erythrocytes.

  14. Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

    Science.gov (United States)

    Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A

    2011-08-01

    To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.

  15. Some procedures for computerized ability testing

    NARCIS (Netherlands)

    van der Linden, Willem J.; Zwarts, Michel A.

    1989-01-01

    For computerized test systems to be operational, the use of item response theory is a prerequisite. As opposed to classical test theory, in item response models the abilities of the examinees and the properties of the items are parameterized separately. Hence, when measuring the abilities of

  16. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source.

    Science.gov (United States)

    Atwood, Robert C; Bodey, Andrew J; Price, Stephen W T; Basham, Mark; Drakopoulos, Michael

    2015-06-13

    Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an 'orthogonal' fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and 'facility-independent': it can run on standard cluster infrastructure at any institution.

  17. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  18. Unfolding and smoothing applied to the quality enhancement of neutron tomographic images

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Silvani, Maria I.; Lopes, Ricardo T.

    2008-01-01

    Resolution and contrast are the major parameters defining the quality of a computer-aided tomographic image. These parameters depend upon several features of the image acquisition system, such as detector resolution, geometrical arrangement of the source-object-detector, beam divergence, source strength, detector efficiency and counting time. Roughly, the detector finite resolution is the main source of systematic errors affecting the separation power of the image acquisition system, while the electronic noise and statistical fluctuation are responsible for the data dispersion, which spoils the contrast. An algorithm has been developed in this work aiming at the improvement of the image quality through the minimization of both types of errors. The systematic ones are reduced by a mathematical unfolding of the position spectra - used as projections to reconstruct the 2D-images - using the Line Spread Function - LSF of the neutron tomographic system. The principle behind this technique is that every single channel contains information about all channels of the spectrum, but it is concealed due to the automatic integration carried out by the detector. Therefore, knowing the shape of this curve, it is possible to retrieve the original spectra. These spectra are unfortunately corrupted by the unavoidable statistical fluctuation, and by oscillations arising from the unfolding process, which strongly affects the quality of the final unfolded image. In order to reduce this impact, the spectra have been filtered by a Fourier transform technique or smoothed with a least square fitting procedure. The algorithm has been applied to spectra of some test-bodies generated by an earlier developed tomographic simulator, which reproduces the spectra furnished by a thermal neutron tomographic system employing a position sensitive detector. The obtained results have shown that the unfolded spectra produce final images capable to resolve features otherwise not achievable with the

  19. Computed tomographic findings in manifesting carriers of Duchenne muscular dystrophy

    NARCIS (Netherlands)

    de Visser, M.; Verbeeten, B.

    1985-01-01

    Clinical and computed tomographic (CT) findings in 3 manifesting carriers of Duchenne muscular dystrophy are reported. CT proved to be an important adjunct to the clinical examination: in all our 3 cases a decrease in density was found in various non-paretic muscles

  20. Design and applications of Computed Industrial Tomographic Imaging System (CITIS)

    International Nuclear Information System (INIS)

    Ramakrishna, G.S.; Umesh Kumar; Datta, S.S.; Rao, S.M.

    1996-01-01

    Computed tomographic imaging is an advanced technique for nondestructive testing (NDT) and examination. For the first time in India a computed aided tomography system has been indigenously developed in BARC for testing industrial components and was successfully demonstrated. The system in addition to Computed Tomography (CT) can also perform Digital Radiography (DR) to serve as a powerful tool for NDT applications. It has wider applications in the fields of nuclear, space and allied fields. The authors have developed a computed industrial tomographic imaging system with Cesium 137 gamma radiation source for nondestructive examination of engineering and industrial specimens. This presentation highlights the design and development of a prototype system and its software for image reconstruction, simulation and display. The paper also describes results obtained with several tests specimens, current development and possibility of using neutrons as well as high energy x-rays in computed tomography. (author)

  1. The CDD system in computed tomographic diagnosis of diverticular disease

    International Nuclear Information System (INIS)

    Pustelnik, Daniel; Elsholtz, Fabian Henry Juergen; Hamm, Bernd; Niehues, Stefan Markus; Bojarski, Christian

    2017-01-01

    Purpose cation in computed tomographic diagnosis and briefly recapitulates its targeted advantages over preliminary systems. Primarily, application of the CDD in computed tomography diagnostics is described. Differences with respect to the categories of the older systems are pointed out on the level of each CDD type using imaging examples. The presented images are derived from our institute according to the S2k criteria. Literature was researched on PubMed. Results The CDD constitutes an improvement compared to older systems for categorizing the stages of diverticular disease. It provides more discriminatory power on the descriptive-morphological level and defines as well as differentiates more courses of the disease. Furthermore, the categories translate more directly into state-of-the-art decision-making concerning hospitalization and therapy. The CDD should be applied routinely in the computed tomographic diagnosis of diverticular disease. Typical imaging patterns are presented.

  2. Terahertz Imaging for Biomedical Applications Pattern Recognition and Tomographic Reconstruction

    CERN Document Server

    Yin, Xiaoxia; Abbott, Derek

    2012-01-01

    Terahertz Imaging for Biomedical Applications: Pattern Recognition and Tomographic Reconstruction presents the necessary algorithms needed to assist screening, diagnosis, and treatment, and these algorithms will play a critical role in the accurate detection of abnormalities present in biomedical imaging. Terahertz biomedical imaging has become an area of interest due to its ability to simultaneously acquire both image and spectral information. Terahertz imaging systems are being commercialized with an increasing number of trials performed in a biomedical setting. Terahertz tomographic imaging and detection technology contributes to the ability to identify opaque objects with clear boundaries,and would be useful to both in vivo and ex vivo environments. This book also: Introduces terahertz radiation techniques and provides a number of topical examples of signal and image processing, as well as machine learning Presents the most recent developments in an emerging field, terahertz radiation Utilizes new methods...

  3. Micro-computed Tomographic Analysis of Mandibular Second Molars with C-shaped Root Canals.

    Science.gov (United States)

    Amoroso-Silva, Pablo Andrés; Ordinola-Zapata, Ronald; Duarte, Marco Antonio Hungaro; Gutmann, James L; del Carpio-Perochena, Aldo; Bramante, Clovis Monteiro; de Moraes, Ivaldo Gomes

    2015-06-01

    The goal of the present study was to evaluate the morphometric aspects of the internal anatomy of the root canal system of mandibular second molars with C-shaped canals. Fifty-two extracted second mandibular molars with C-shaped canals, fused roots, and radicular grooves were selected from a Brazilian population. The samples were scanned with a micro-computed tomographic scanner at a voxel size of 19.6 μm. The root canal cross sections were recorded as C1, C2, C3, and C4 root canal configurations according to the modified Melton classification. Morphometric parameters, including the major and minor diameters of the root canals, the aspect ratio, the roundness, and the tridimensional configuration (merging, symmetric, and asymmetric), were evaluated. The 3-dimensional reconstruction images of the teeth indicated an even distribution within the sample. The analysis of the prevalence of the different cross-sectional configurations of the C-shaped molars revealed that these were predominantly of the C4 and C3 configurations (1 mm from the apex) and the C1 and C2 configurations in the cervical third. According to the morphometric parameters, the C1 and the distal aspect of the C2 configurations exhibited the lowest roundness values and higher values for the area, major diameter, and aspect ratio in the apical third. Mandibular molars with C-shaped root canals exhibited similar distributions of symmetric, asymmetric, and merging type canals. The C1 configuration and the distal aspect of the C2 configuration exhibited the highest area values, low roundness values, and large apical diameters. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Heidelberg Retina Tomograph for the Detection of Glaucoma

    Directory of Open Access Journals (Sweden)

    Barbara Cvenkel

    2012-06-01

    Full Text Available Heidelberg Retina Tomograph (HRT is a confocal scanning laser ophthalmoscope which acquires and analyzes 3-dimensional images of the optic nerve head. The latest instrument HRT3 includes software with larger ethinic-specific normative database. This review summarizes relevant published literature on HRT in diagnosing glaucoma, detecting glaucoma progression, the diagnostic accuracy of HRT among other imaging devices and its role in clinical practice.

  5. Ethics and the Computerization of Pharmacy.

    Science.gov (United States)

    McCarthy, Robert L.; Perrolle, Judith A.

    1991-01-01

    The current and potential impact of computerization on pharmacy practice is discussed, focusing on ethical dilemmas in the pharmacist-patient relationship, confidentiality of records, and the role of artificial intelligence in decision making about drug therapy. Case studies for use by teachers of pharmaceutical ethics are provided. (Author/MSE)

  6. How will computerization revolutionize managed care?

    Science.gov (United States)

    Trabin, T

    1994-01-01

    Computerization of behavioral health care information systems is revolutionizing how payors, managed care companies, and providers exchange information. In this article, an imaginary scenario is depicted of how patient data will be accessed and communicated to facilitate care management of behavioral health care services in the near future.

  7. New applications to computerized tomography: analysis of solid dosage forms produced by pharmaceutical industry

    International Nuclear Information System (INIS)

    Oliveira Junior, Jose Martins de; Martins, Antonio Cesar Germano

    2009-01-01

    Full text: In recent years, computerized tomography (CT) has been used as a new probe to study solid dosage forms (tablets) produced by pharmaceutical industry. This new approach to study tablet and powder, or granulation, properties used in pharmaceutical industry is very suitable. First because CT can generate information that traditional technologies used in this kind of analysis can not, such as, density distribution of internal structures and tablet dimensions, pore size distribution, particle shape information, and also investigation of official and unofficial (counterfeit) copies of solid dosage forms. Second because CT is a nondestructive technique, allowing the use of tablets or granules in others analysis. In this work we discus how CT can be used to acquire and reconstruct internal microstructure of tablets and granules. CT is a technique that is based on attenuation of X-rays passing through matter. Attenuation depends on the density and atomic number of the material that is scanned. In this work, a micro-CT X-ray scanner (manufactured by the group of Applied Nuclear Physics at University of Sorocaba) was used to obtain three-dimensional images of the tablets and granules for nondestructive analysis. These images showed a non uniform density distribution of material inside some tablets, the morphology of some granules analyzed, the integrity of the liquid-filled soft-gelatin capsule and so on. It could also be observed that the distribution of different constituents presents an osmotic controlled-release dosage form. The present work shows that it is possible to use X-ray microtomography to obtain useful qualitative and quantitative information on the structure of pharmaceutical dosage forms. (author)

  8. The Use of Chest Computed Tomographic Angiography in Blunt Trauma Pediatric Population.

    Science.gov (United States)

    Hasadia, Rabea; DuBose, Joseph; Peleg, Kobi; Stephenson, Jacob; Givon, Adi; Kessel, Boris

    2018-02-05

    Blunt chest trauma in children is common. Although rare, associated major thoracic vascular injuries (TVIs) are lethal potential sequelae of these mechanisms. The preferred study for definitive diagnosis of TVI in stable patients is computed tomographic angiography imaging of the chest. This imaging modality is, however, associated with high doses of ionizing radiation that represent significant carcinogenic risk for pediatric patients. The aim of the present investigation was to define the incidence of TVI among blunt pediatric trauma patients in an effort to better elucidate the usefulness of computed tomographic angiography use in this population. A retrospective cohort study was conducted including all blunt pediatric (age blunt trauma victims, 119,821patients were younger than 14 years. Twelve (0.0001%, 12/119821) of these children were diagnosed with TVI. The most common mechanism in this group was pedestrian hit by a car. Mortality was 41.7% (5/12). Thoracic vascular injury is exceptionally rare among pediatric blunt trauma victims but does contribute to the high morbidity and mortality seen with blunt chest trauma. Computed tomographic angiography, with its associated radiation exposure risk, should not be used as a standard tool after trauma in injured children. Clinical protocols are needed in this population to minimize radiation risk while allowing prompt identification of life-threatening injuries.

  9. Radiation diagnosis of different forms of acute pancreatitis

    International Nuclear Information System (INIS)

    Stashuk, G.A.; Dubrova, S.Eh.; Emel'yanova, L.N.; Tripatkhi, S.

    1999-01-01

    Using the data on 123 patient with different forms of pancreatitis the ultrasonic and computerized tomographic semiotics of these states is described. It is shown that ultrasonography and computerized tomography are highly informative in diagnosis of different forms of the disease and its complications. Both methods not only assess the pancreatic parenchyma state, the spreading of process into adjacent anatomic structures, but also the dynamic control and perform diagnostic and treatment measures under visual control [ru

  10. Transformations and algorithms in a computerized brain atlas

    International Nuclear Information System (INIS)

    Thurfjell, L.; Bohm, C.; Eriksson, L.; Karolinska Institute/Hospital, Stockholm

    1993-01-01

    The computerized brain atlas constructed at the Karolinska Hospital, Stockholm, Sweden, has been further developed. This atlas was designed to be employed in different fields of neuro imaging such as positron emission tomography (PET), single photon emission tomography (SPECT), computerized tomography (CT) and magnetic resonance imaging (MR). The main objectives with the atlas is to aid the interpretation of functional images by introducing anatomical information, to serve as a tool in the merging of data from different imaging modalities and to facilitate the comparisons of data from different individuals by allowing for anatomical standardization of individual data. The purpose of this paper is to describe the algorithms and transformations used in the implementation of the atlas software

  11. Morphologic analysis of Japanese adult sacroiliac joint using computed tomographic images

    International Nuclear Information System (INIS)

    Pan, Xuanchao; Takayama, Akinori; Shibata, Yasuaki; Ito, Hiromoto

    2003-01-01

    The purpose of this study was to study the relationship of angles in adult sacroiliac joints (SJ) with laterality, age, gender, degeneration, childbearing in different locations. The study was performed in 92 healthy Japanese adult volunteers (46 males and 46 females, aged 21∼86 years) who had no low back complaints. Axial computed tomographic (CT) images were obtained using an X-VIGOR apparatus (Toshiba Medical Inc. Japan). The angle measurements were taken directly using soft National Institutes of Health (NIH) Image 1.61 (Scion Inc. USA). We examined possible factors. Statistical evaluation was calculated using t-test by soft SPSS (SPSS Inc. Japan). Our findings indicated that SJ angles had no relationships with laterality, gender. But from upper part to lower part, the average of SJ angle was 7.61 deg±8.7 deg, 5.16 deg±7.3 deg, -0.85 deg±7.3 deg respectively in the left and 6.56 deg±9.4 deg, 4.10 deg±7.2 deg, -2.30 deg±7.0 deg in the right. The difference is significant between lower part and upper-middle part (P<0.05). Our results provided new anatomic and morphological data for better understandings of SJ in the clinic work. (author)

  12. Gastrointestinal stromal tumors: retrospective analysis of the computer-tomographic aspects.

    Science.gov (United States)

    Lupescu, Ioana G; Grasu, Mugur; Boros, Mirela; Gheorghe, Cristian; Ionescu, Mihnea; Popescu, Irinel; Herlea, Vlad; Georgescu, Serban A

    2007-06-01

    To describe the computer-tomographic (CT) aspects of gastrointestinal stromal tumors (GISTs) in correlation to their histology. The medical records of all patients at our hospital with a histologic diagnosis of GIST between January 2002 and June 2006, and investigated before surgery by CT, were reviewed. Two radiologists with knowledge of the diagnosis reviewed the CT findings. Amongst 15 cases of GISTs, 9 cases involved the stomach and 4 cases the small intestine. Location of the primary tumor could not be determined for 2 of 15 tumors, because of the presence of extensive peritoneal metastases. Most primary tumors were predominantly extraluminal (13 cases) while two were clearly endoluminal. The mean diameter of the primary tumor was 8 cm. The tumor margin was well defined in 12 patients and irregular in 3 cases. Central fluid attenuation was present in 11 tumors, while central gas was seen in two cases. Metastases were seen in 2 cases at presentation and in another 2 patients during follow-up. Spread was exclusive to the liver or peritoneum. Visceral obstruction was absent even in extensive peritoneal metastatic disease. Ascites was an unusual finding. CT plays an important role not only in the detection and the localization but also in the evaluation of the extension and follow-up of theses tumors. Using only CT aspects, we can only suspect the diagnosis to GISTs. Often other soft-tissue tumors with gastrointestinal involvement can mimic GISTs. In all cases histological diagnosis is essential.

  13. Dynamics of the aorta and its sidebranches : implications for endovascular treatment of aortic disease

    NARCIS (Netherlands)

    Muhs, B.E.

    2007-01-01

    The main objective of this thesis is to critically evaluate the clinical results of emerging aortic endovascular therapies and then to utilize dynamic imaging modalities [EKG gated dynamic computerized tomographic angiography (CTA) and magnetic resonance angiography (MRA)] to understand the

  14. Individual Differences in Computerized Adaptive Testing.

    Science.gov (United States)

    Kim, JinGyu

    Research on the major computerized adaptive testing (CAT) strategies is reviewed, and some findings are reported that examine effects of examinee demographic and psychological characteristics on CAT strategies. In fixed branching strategies, all examinees respond to a common routing test, the score of which is used to assign examinees to a…

  15. Cumulative Effects of Concussion History on Baseline Computerized Neurocognitive Test Scores: Systematic Review and Meta-analysis.

    Science.gov (United States)

    Alsalaheen, Bara; Stockdale, Kayla; Pechumer, Dana; Giessing, Alexander; He, Xuming; Broglio, Steven P

    It is unclear whether individuals with a history of single or multiple clinically recovered concussions exhibit worse cognitive performance on baseline testing compared with individuals with no concussion history. To analyze the effects of concussion history on baseline neurocognitive performance using a computerized neurocognitive test. PubMed, CINAHL, and psycINFO were searched in November 2015. The search was supplemented by a hand search of references. Studies were included if participants completed the Immediate Post-concussion Assessment and Cognitive Test (ImPACT) at baseline (ie, preseason) and if performance was stratified by previous history of single or multiple concussions. Systematic review and meta-analysis. Level 2. Sample size, demographic characteristics of participants, as well as performance of participants on verbal memory, visual memory, visual-motor processing speed, and reaction time were extracted from each study. A random-effects pooled meta-analysis revealed that, with the exception of worsened visual memory for those with 1 previous concussion (Hedges g = 0.10), no differences were observed between participants with 1 or multiple concussions compared with participants without previous concussions. With the exception of decreased visual memory based on history of 1 concussion, history of 1 or multiple concussions was not associated with worse baseline cognitive performance.

  16. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  17. Implementation of computerized add-on testing for hospitalized patients in a large academic medical center.

    Science.gov (United States)

    Kim, Ji Yeon; Kamis, Irina K; Singh, Balaji; Batra, Shalini; Dixon, Roberta H; Dighe, Anand S

    2011-05-01

    Physician requests for additional testing on an existing laboratory specimen (add-ons) are resource intensive and generally require a phone call to the laboratory. Verbal orders such as these have been noted to be associated with errors in accuracy. The aim of this study was to compare a novel computerized system for add-on requests to the prior verbal system. We compare the computerized add-on request system to the verbal system with respect to order completeness and workflow. We demonstrate that the computerized add-on system resulted in the complete in-laboratory documentation of the add-on request 100% of the time, compared to 58% with the verbal add-on system. In addition, we show that documentation of a verbal add-on request in the electronic medical record (EMR) occurred for 4% of requests, while in the computerized system EMR documentation occurred 100% of the time. We further demonstrate that the computerized add-on request process was well accepted by providers and did not significantly change the test mix of the add-on requests. In computerized physician order entry (CPOE) implementations, add-on order functionality should be considered so these orders are documented in the EMR.

  18. Journal of EEA, Vol. 30, 2013 COMPUTERIZED FACILITIES ...

    African Journals Online (AJOL)

    dell

    Key words: Computer Aided Layout Design,. Construction ... Commonly used software are ... popular improvement-type methods are. Computerized Relative Allocation of Facilities .... closeness ratings values are given different numerical.

  19. Comparison between visual and computerized cardiotocography in low risk pregnancy

    International Nuclear Information System (INIS)

    Mirghani, Hisham M.; Khair, Howaida

    2005-01-01

    To compare between visual and computerized cardiotocography (cCTG) in low-risk pregnant women in predicting pregnancy outcome. One hundred and fifty-three consecutive computerized fetal heart tracings were recorded from non-laboring pregnant women at >/- 30 weeks gestation. All traces were reviewed by 2 experienced obstetricians. The study was carried out at Al-Ain Medical District, United Arab Emirates, between August 2004 and December 2004. Of the 153 pregnant women, 11 (7.2%) were delivered by cesarean section. The interobserver agreement was 0.60. The observers cCTG agreement were 0.48 and 0.45. The difference in cesarean section rate was not statistically significant. Observers interpretation and cCTG did not correlate well with Apgar score at 5 minutes and admission to special care baby unit. Computerized CTG has little advantage over conventional CTG in the prediction of Apgar score and need for neonatal intensive care unit admission in a low-risk population. (author)

  20. A computerized system to measure interproximal alveolar bone levels in epidemiologic, radiographic investigations. I

    International Nuclear Information System (INIS)

    Wouters, F.R.; Jon-And, C.; Frithiof, L.; Soeder, P.Oe.; Lavstedt, S.

    1988-01-01

    The aims of the study were to adapt a computerized system to epidemiologic conditions, for rapid full-mouth measurements of alveolar bone levels from X5-magnified periapical radiographs and to analyze the variations in measurement due to different system components. Full-mouth measurements of interproximal alveolar bone height in percentage of root and tooth lengths were completed within av average time of 15 min. per set of radiographs. An analysis of variance showed that the examiner variation in measurement of a linear scale distance was 0.02 mm. The measurement accuracy was different for different distances. Each distance (d) measured with this system should therefore be calibrated with the equation Y = -0.007 - 0.014 (log 3d - 1.50) where Y is the estimate of measurement accuracy. The present computerized system enabled rapid recordings and demonstrated good measurement precision and accuracy. These are valuable features in epidemiologic investigations

  1. Computerized management support for swine breeding farms

    NARCIS (Netherlands)

    Huirne, R.B.M.

    1990-01-01

    1. INTRODUCTION

    The investigations described in this thesis have been directed towards computerized management support for swine breeding farms, focused on sow productivity and profitability. The study is composed of three basic parts: (1) basic description and

  2. The Computerized Reference Department: Buying the Future.

    Science.gov (United States)

    Kriz, Harry M.; Kok, Victoria T.

    1985-01-01

    Basis for systematic computerization of academic research library's reference, collection development, and collection management functions emphasizes productivity enhancement for librarians and support staff. Use of microcomputer and university's mainframe computer to develop applications of database management systems, electronic spreadsheets,…

  3. Tomographic Image Reconstruction Using Training Images with Matrix and Tensor Formulations

    DEFF Research Database (Denmark)

    Soltani, Sara

    the image resolution compared to a classical reconstruction method such as Filtered Back Projection (FBP). Some priors for the tomographic reconstruction take the form of cross-section images of similar objects, providing a set of the so-called training images, that hold the key to the structural......Reducing X-ray exposure while maintaining the image quality is a major challenge in computed tomography (CT); since the imperfect data produced from the few view and/or low intensity projections results in low-quality images that are suffering from severe artifacts when using conventional...... information about the solution. The training images must be reliable and application-specific. This PhD project aims at providing a mathematical and computational framework for the use of training sets as non-parametric priors for the solution in tomographic image reconstruction. Through an unsupervised...

  4. Evaluation of paranasal sinus mucosa in coal worker's pneumoconiosis - A computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, H.; Altin, R.; Mahmutyazicioglu, K.; Kart, L.; Uzun, L.; Savranlar, A.; Davcanci, H.; Gundogdu, S. [Zonguldak Karaelmas University, Zonguldak (Turkey). School of Medicine

    2004-09-01

    Objective: To evaluate by computed tomographic scanning the paranasal mucosal changes of coal workers with and without pneumoconiosis. Methods: Examination of images and scores from paranasal computed tomographic scans. The study participants were 26 coal workers with pneumoconiosis, 29 coal workers without pneumoconiosis, and 20 controls. All were men. The extent and patterns of inflamatory paranasal sinus disease were evaluated on computed, tomographic scans by 2 radiologists using the terminology and definitions of Newman and associates. Results: Interobserver agreement for the presence of abnormalities was from good to excellent (K, 0.63-0.89). The mucosal scores of individuals and groups were higher for coal workers than for control subjects. Both scores were significantly higher in the pneumoconiosis group than in the 2 other groups. Conclusions: This study shows that paranasal sinuses were affected more severely in coal workers than in control subjects. In coal workers with pneumoconiosis, the affection was most severe. The relationship between coal dust exposure and paranasal mucosal changes needs further study.

  5. Computed tomographic study in children with microcephaly

    International Nuclear Information System (INIS)

    Ito, Masatoshi; Okuno, Takehiko; Mikawa, Haruki

    1989-01-01

    Computed tomographic (CT) brain scanning was performed on fifty-eight infants and children with microcephaly. CT scans were useful for detecting unsuspected brain lesions and for diagnosing underlying diseases. The head size did not correlate with the CT findings, the degree of mental retardation, or the existence of motor disturbance or epilepsy. On the other hand, the CT findings were correlated with the degree of mental retardation, and the existence of motor disturbance or epilepsy. CT scans were useful for determining the prognosis of the microcephaly. (author)

  6. Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery.

    Science.gov (United States)

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and

  7. The effect of sport on computerized electrocardiogram measurements in college athletes.

    Science.gov (United States)

    Gademan, Maaike G J; Uberoi, Abhimanyu; Le, Vy-Van; Mandic, Sandra; van Oort, Eddy R; Myers, Jonathan; Froelicher, Victor F

    2012-02-01

    Broad criteria for abnormal electrocardiogram (ECG) findings, requiring additional testing, have been recommended for preparticipation exams (PPE) of athletes. As these criteria have not considered the sport in which athletes participate, we examined the effect of sports on the computerized ECG measurements obtained in college athletes. During the Stanford 2007 PPE, computerized 12-lead ECGs (Schiller AG) were obtained in 641 athletes (350 male/291 female, age 19.5 ± 2 years). Athletes were engaged in 22 different sports and were grouped into 16 categories: baseball/softball, basketball, crew, crosscountry, fencing, field events, football linemen, football other positions, golf, gymnastics, racquet sports, sailing, track/field, volleyball, water sports, and wrestling. The analysis focused on ECG leads V2, aVF and V5 which provide a three-dimensional representation of the heart's electrical activity. As marked ECG differences exist between males and females, the data are presented by gender. In males, ANOVA analysis yielded significant ECG differences between sports for heart rate, QRS duration, QTc, J-amplitude in V2 and V5, spatial vector length (SVL) of the P wave, SVL R wave, and SVL T wave, and RS(sum) (p sports were found for heart rate, QRS duration, QRS axis and SVL T wave (p sports, and these differences were more apparent in males than females. Therefore, sport-specific ECG criteria for abnormal ECG findings should be developed to obtain a more useful approach to ECG screening in athletes.

  8. Some aspects of evaluation of image quality in computerized tomography

    International Nuclear Information System (INIS)

    Travassos, Paulo Cesar Baptista; Peixoto, Jose Guilherme; Almeida, Carlos Eduardo Veloso de; Campos, Luciana Tourinho; Magalhaes, Luis Alexandre

    2016-01-01

    The evaluation of CT scanners image quality includes measuring the Hounsfield values, HU, using a table with the limit values. This table does not consider that different devices have different effective energies, which may cause some false results. The evaluation of 90 computerized tomography, by the American College Radiology methodology, showed that some failed devices in the evaluation showed excellent linear fit between the values of the linear attenuation coefficients calculated for the actual energy used, according to the HU values. The analysis of the coefficient of determination suggests that 10 of these devices could have been approved. (author)

  9. A tomographic test of cosmological principle using the JLA compilation of type Ia supernovae

    Science.gov (United States)

    Chang, Zhe; Lin, Hai-Nan; Sang, Yu; Wang, Sai

    2018-05-01

    We test the cosmological principle by fitting a dipolar modulation of distance modulus and searching for an evolution of this modulation with respect to cosmological redshift. Based on a redshift tomographic method, we divide the Joint Light-curve Analysis compilation of supernovae of type Ia into different redshift bins, and employ a Markov-Chain Monte-Carlo method to infer the anisotropic amplitude and direction in each redshift bin. However, we do not find any significant deviations from the cosmological principle, and the anisotropic amplitude is stringently constrained to be less than a few thousandths at 95% confidence level.

  10. Computerized health information and the demand for medical care.

    Science.gov (United States)

    Wagner, Todd H; Jimison, Holly B

    2003-01-01

    Consumer health information, once the domain of books and booklets, has become increasingly digitized and available on the Internet. This study assessed the effect of using computerized health information on consumers' demand for medical care. The dependent variable was self-reported number of visits to the doctor in the past year. The key independent variable was the use of computerized health information, which was treated as endogenous. We tested the effect of using computerized health information on physician visits using ordinary least squares, instrumental variables, fixed effects, and fixed-effects instrumental variables models. The instrumental variables included exposure to the Healthwise Communities Project, a community-wide health information intervention; computer ownership; and Internet access. Random households in three cities were mailed questionnaires before and after the Healthwise Communities Project. In total, 5909 surveys were collected for a response rate of 54%. In both the bivariate and the multivariate analyses, the use of computerized health information was not associated with self-reported entry into care or number of visits. The instrumental variables models also found no differences, with the exception that the probability of entering care was significantly greater with the two-stage conditional logit model (P information is intuitively appealing, we found little evidence of an association between using a computer for health information and self-reported medical visits in the past year. This study used overall self-reported utilizations as the dependent variable, and more research is needed to determine whether health information affects the health production function in other important ways, such as the location of care, the timing of getting care, or the intensity of treatment.

  11. The evolution of the market for commercial computerized physician order entry and computerized decision support systems for prescribing.

    Science.gov (United States)

    Mozaffar, Hajar; Williams, Robin; Cresswell, Kathrin; Morrison, Zoe; Bates, David W; Sheikh, Aziz

    2016-03-01

    To understand the evolving market of commercial off-the-shelf Computerized Physician Order Entry (CPOE) and Computerized Decision Support (CDS) applications and its effects on their uptake and implementation in English hospitals. Although CPOE and CDS vendors have been quick to enter the English market, uptake has been slow and uneven. To investigate this, the authors undertook qualitative ethnography of vendors and adopters of hospital CPOE/CDS systems in England. The authors collected data from semi-structured interviews with 11 individuals from 4 vendors, including the 2 most entrenched suppliers, and 6 adopter hospitals, and 21 h of ethnographic observation of 2 user groups, and 1 vendor event. The research and analysis was informed by insights from studies of the evolution of technology fields and the emergence of generic COTS enterprise solutions. Four key themes emerged: (1) adoption of systems that had been developed outside of England, (2) vendors' configuration and customization strategies, (3) localized adopter practices vs generic systems, and (4) unrealistic adopter demands. Evidence for our over-arching finding concerning the current immaturity of the market was derived from vendors' strategies, adopters' reactions to the technology, and policy makers' incomplete insights. The CPOE/CDS market in England is still in an emergent phase. The rapid entrance of diverse products, triggered by federal policy initiatives, has resulted in premature adoption of systems that do not yet adequately meet the needs of hospitals. Vendors and adopters lacked understanding of how to design and implement generic solutions to meet diverse user needs. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Chief objectives of the development of X-ray equipment engineering in Russia

    International Nuclear Information System (INIS)

    Blinov, N.N.; Varshavskij, Yu.V.; Zelikman, M.I.

    1997-01-01

    Based on the world tendencies in the development of X-ray diagnostic instruments the main problems int he development of domestic X-ray diagnostic equipment engineering are analyzed. Variant of basic equipment for modern X-ray room for digital biomedical radiography is proposed. Tendencies int he instrumentation of X-ray diagnosis are the following ones: X-ray computerized tomograph creation, development of telecontrolled X-ray computerized. complexes for biomedical X-ray complexes for digital biomedical radiography, automation of the film development

  13. A general purpose tomographic program with combined inversions

    International Nuclear Information System (INIS)

    Xu Wenbin; Dong Jiafu; Li Fanzhu

    1996-01-01

    A general tomographic program has been developed by combining the Bessel expansion with the Zernicke expansion. It is useful for studying of the magnetic island structure of the tearing mode and in reconstructing the density profiles of impurities in tokamak plasmas. This combined method have the advantages of both expansions, i.e. there will be no spurious images in the edge and it will be of high inverse precision in the center of plasma

  14. Simulation of Tomographic Reconstruction of Magnetosphere Plasma Distribution By Multi-spacecraft Systems.

    Science.gov (United States)

    Kunitsyn, V.; Nesterov, I.; Andreeva, E.; Zelenyi, L.; Veselov, M.; Galperin, Y.; Buchner, J.

    A satellite radiotomography method for electron density distributions was recently proposed for closely-space multi-spacecraft group of high-altitude satellites to study the physics of reconnection process. The original idea of the ROY project is to use a constellation of spacecrafts (one main and several sub-satellites) in order to carry out closely-spaced multipoint measurements and 2D tomographic reconstruction of elec- tron density in the space between the main satellite and the subsatellites. The distances between the satellites were chosen to vary from dozens to few hundreds of kilometers. The easiest data interpretation is achieved when the subsatellites are placed along the plasma streamline. Then, whenever a plasma density irregularity moves between the main satellite and the subsatellites it will be scanned in different directions and we can get 2D distribution of plasma using these projections. However in general sub- satellites are not placed exactly along the plasma streamline. The method of plasma velocity determination relative to multi-spacecraft systems is considered. Possibilities of 3D tomographic imaging using multi-spacecraft systems are analyzed. The model- ing has shown that efficient scheme for 3D tomographic imaging would be to place spacecrafts in different planes so that the angle between the planes would make not more then ten degrees. Work is supported by INTAS PROJECT 2000-465.

  15. Computerized bone density analysis of the proximal phalanx of the horse

    International Nuclear Information System (INIS)

    Thompson, K.N.; Cheung, T.K.; Putnam, M.

    1996-01-01

    This study utilized computed tomography to determine the density patterns and the subchondral bone thickness of the first phalanx of the horse. An image processing system and commercially available software were used to process the computed tomographic slices obtained from the first phalanges of a 2-year-old Thoroughbred horse. The thickness and density of the medial and lateral cortices in the mid-shaft of the bone were similar; however, the cortex on the dorsal aspect was more dense and extended farther toward the proximal and distal aspects of the bone than the cortex on the palmar aspect. Density of the cortical bone was highest at the region of the bone with the smallest diameter. The cortical bone density at mid-shaft was approximately 3.5 times the cancellous bone density at the proximal aspect and 2.5 times that at the distal aspect of the bone. A moderate correlation (r = 0.53, p < 0.01)was found between the subchondral bone density and thickness. Despite limited numbers of specimens used, this study demonstrated the potential applications of computed tomography for investigating equine joint mechanics and diseases

  16. Computerized Adaptive Test (CAT) Applications and Item Response Theory Models for Polytomous Items

    Science.gov (United States)

    Aybek, Eren Can; Demirtasli, R. Nukhet

    2017-01-01

    This article aims to provide a theoretical framework for computerized adaptive tests (CAT) and item response theory models for polytomous items. Besides that, it aims to introduce the simulation and live CAT software to the related researchers. Computerized adaptive test algorithm, assumptions of item response theory models, nominal response…

  17. A new method to evaluate image quality of nuclear medicine tomographs

    International Nuclear Information System (INIS)

    Giannone, C.A.; Cabrejas, M.L.; Arashiro, J.A.

    2002-01-01

    Objective: To evaluate the usefulness of a new statistics, the Performance Index (PI), in order to make judgements about diagnostic accuracy of nuclear medicine tomographs (NMT). Methods: A phantom was designed for blind evaluation of device performance. It has 8 cold cylindrical inserts of different diameters. Acquisitions were performed in 40 labs following a defined protocol (under an International Atomic Energy Agency survey). Non-reconstructed set of views were processed and evaluated at a central lab using the same protocol for all the studies. Lesion detection was performed over eye-selected reconstructed slices applying a smoothing filter and a look up table (LUT) with fixed thresholds: counts/pixel = mean ± K . Standard deviation, with K=1,2,3 or >3. The number and location of the inserts was reported by blind observers, afterwards the true and false positive fractions was assessed by another observer. Receiver operating characteristic (ROC) analysis cannot be applied in our experiment where each image with multiple simulated lesions needs to be evaluated. A free-response ROC analysis, developed for observers' performance evaluation, has also flaws. Moreover, our goal was to assess device performance minimising the observer component. A new index, PI, that considers simultaneously the number of true and false positives (TP and FP) was evaluated to categorise NMT. PI is the ratio between the positive predictive value and the sensitivity, expressed as its complement adding a constant to avoid a singularity. Results: The smoothing filter and the selected LUT leads to observers-independent simulated lesion detection. Based on statistical analysis (bootstrapping), it is concluded that the number of observed false positives must be lower than the observed true positives (no. FP < no. TP) to accept an instrument for clinical purposes. Moreover, the number of observed TP must be considered in relation to a minimum tomographic resolution needed to achieve enough

  18. The use of PROLOG for computerized Technical Specifications

    International Nuclear Information System (INIS)

    Lidsky, L.M.; Lanning, D.D.; Dobrzeniecki, A.B.; Meyers, K.; Reese, T.G.

    1987-01-01

    The task of deciding whether a particular nuclear plant condition is in compliance with its Technical Specifications is, in principle, algorithmic. However, the implicit algorithm is so complex and the required level of confidence in code validity is so high that traditional methods of computerized analysis have proven unsatisfactory. PROLOG provides a close match to the explicit semantic structure of the written specifications, a good tool for analysis of the implicit subsystem operability trees and, by virtue of its declarative style and imbedded logical structure, greatly simplifies the problem of code validation. LCOM, a PROLOG representation of a subset of BWR Technical Specifications, was developed to explore the applicability of PROLOG in this problem domain and to provide benchmark data for full-scale implementations. The declarative style and built-in unification mechanism of PROLOG does substantially simplify the process of program construction and validation. Extrapolations indicate processing times for a complete Tech Spec implementation of ≤ 1 minute in systems capable of ≥ 20 KLIPS

  19. Computerized database management system for breast cancer patients.

    Science.gov (United States)

    Sim, Kok Swee; Chong, Sze Siang; Tso, Chih Ping; Nia, Mohsen Esmaeili; Chong, Aun Kee; Abbas, Siti Fathimah

    2014-01-01

    Data analysis based on breast cancer risk factors such as age, race, breastfeeding, hormone replacement therapy, family history, and obesity was conducted on breast cancer patients using a new enhanced computerized database management system. My Structural Query Language (MySQL) is selected as the application for database management system to store the patient data collected from hospitals in Malaysia. An automatic calculation tool is embedded in this system to assist the data analysis. The results are plotted automatically and a user-friendly graphical user interface is developed that can control the MySQL database. Case studies show breast cancer incidence rate is highest among Malay women, followed by Chinese and Indian. The peak age for breast cancer incidence is from 50 to 59 years old. Results suggest that the chance of developing breast cancer is increased in older women, and reduced with breastfeeding practice. The weight status might affect the breast cancer risk differently. Additional studies are needed to confirm these findings.

  20. A case of neurosarcoidosis monitored by computerized tomography

    International Nuclear Information System (INIS)

    Kubota, Toshihiko; Kimura, Makoto; Komai, Toshio; Yamamoto, Shinjiro; Yamamura, Itaru

    1979-01-01

    A 21-year-old man complaining of impaired visual acuity was admitted to the hospital. Physical examinations showed asymptomatic bilateral hilar lymphadenopathy and cardiomyopathy. Neurological findings disclosed left blindness and right temporal hemianopsia. Computerized tomography, pneumoencephalography and carotid angiography revealed a suprasellar mass. After the admission, the following symptoms deteriorated rapidly: diabetes insipidus, anterior pituitary dysfunction, visual loss of the right eye and hepatomegaly, subsequently consciousness disorder developed during a month though he was given steroids. The more deteriorated the clinical course, the larger the suprasellar mass with expanding hydrocephalus in repeated computerized tomographies. After the ventriculo-peritoneal shunt operation, consciousness improved. Diabetes insipidus also improved after Diabenese administration. On the operation, adhesive arachnoiditis over all the frontotemporal cortex and swollen purplishly red optic chiasm were exposed. Microscopically the specimen from the optic chiasm evidenced a sarcoid granuloma which composed of epitheroid cells, lymphocytes and multi-nucleated giant cells with numerous hemosiderin droplets. The specimen from the surface of the left frontal lobe showed thick fibrosis in the subarachnoid space. By steroids therapy, diabetes insipidus and hepatomegaly disappeared five months after the admission, whereas blindness never recovered. He died of developed status epilepticus eleven months after the admission. The authors reviewed neuroradiological findings of neurocarcoidosis based on pathological findings in the literature, and emphasized that computerized tomography was the most useful for diagnosis and treatment of neurosarcoidosis. (author)