WorldWideScience

Sample records for computer-aided kinetic feature

  1. Values of kinetic features measured by computer-aided for breast MRI

    International Nuclear Information System (INIS)

    Zhang Lina; Zhao Zuowei; Song Qingwei; Wang Shaowu; Miao Yanwei

    2012-01-01

    Objective: To investigate the value of kinetic features measured by computer-aided diagnosis (CAD) for breast MRI. Methods: One hundred and sixty four lesions diagnosed pathologically by operation or biopsy comprised the analysis set. Automated lesion kinetic information from CADStream programs for breast MRI was identified. Three CAD variables were compared for benign and malignant lesions: initial phase peak enhancement (greatest percentage of signal intensity increase on first contrast enhanced sequence), delayed phase enhancement categorized by a single type of kinetics comprising the largest percentage of enhancement (washout, plateau, or persistent), and delayed phase enhancement categorized by single most suspicious type of kinetics (any washout > any plateau > any persistent). Morphological characteristics of breast lesions were described according to breast imaging and reporting data system (BI-RADS). Initial phase peak enhancement mean values between benign and malignant breast lesions were compared by using Wilcoxon rank-sum test, delayed phase enhancement categorized by a single type of kinetics comprising the largest percentage of enhancement or by single most suspicious type of kinetics between benign and malignant breast lesions were compared by using Chi-square test. Results: There were 72 benign and 92 malignant breast lesions. A total of 123 (75.0%) mass lesions were identified,and the other 41 (25.0%) lesions showed no mass. Thirty lesions were BI-RADS-MRI 2, 68 lesions were BI-RADS-MRI 3, 43 lesions were BI-RADS-MRI 4, 23 lesions were BI-RADS-MRI 5. Initial phase peak enhancement mean values of benign and malignant lesions were 237% (69% to 629%) and 336% (86% to 793%), respectively. There was no significant difference between benign and malignant lesions in initial peak enhancement mean value (Z=-1.626, P=0.104). Delayed phase enhancement categorized by single most suspicious type of kinetics (any washout > any plateau > any persistent) for

  2. Computer-Aided Construction of Chemical Kinetic Models

    Energy Technology Data Exchange (ETDEWEB)

    Green, William H. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2014-12-31

    The combustion chemistry of even simple fuels can be extremely complex, involving hundreds or thousands of kinetically significant species. The most reasonable way to deal with this complexity is to use a computer not only to numerically solve the kinetic model, but also to construct the kinetic model in the first place. Because these large models contain so many numerical parameters (e.g. rate coefficients, thermochemistry) one never has sufficient data to uniquely determine them all experimentally. Instead one must work in “predictive” mode, using theoretical rather than experimental values for many of the numbers in the model, and as appropriate refining the most sensitive numbers through experiments. Predictive chemical kinetics is exactly what is needed for computer-aided design of combustion systems based on proposed alternative fuels, particularly for early assessment of the value and viability of proposed new fuels before those fuels are commercially available. This project was aimed at making accurate predictive chemical kinetics practical; this is a challenging goal which requires a range of science advances. The project spanned a wide range from quantum chemical calculations on individual molecules and elementary-step reactions, through the development of improved rate/thermo calculation procedures, the creation of algorithms and software for constructing and solving kinetic simulations, the invention of methods for model-reduction while maintaining error control, and finally comparisons with experiment. Many of the parameters in the models were derived from quantum chemistry calculations, and the models were compared with experimental data measured in our lab or in collaboration with others.

  3. Decision trees and integrated features for computer aided mammographic screening

    Energy Technology Data Exchange (ETDEWEB)

    Kegelmeyer, W.P. Jr.; Groshong, B.; Allmen, M.; Woods, K.

    1997-02-01

    Breast cancer is a serious problem, which in the United States causes 43,000 deaths a year, eventually striking 1 in 9 women. Early detection is the only effective countermeasure, and mass mammography screening is the only reliable means for early detection. Mass screening has many shortcomings which could be addressed by a computer-aided mammographic screening system. Accordingly, we have applied the pattern recognition methods developed in earlier investigations of speculated lesions in mammograms to the detection of microcalcifications and circumscribed masses, generating new, more rigorous and uniform methods for the detection of both those signs. We have also improved the pattern recognition methods themselves, through the development of a new approach to combinations of multiple classifiers.

  4. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin; Hollingsworth, Alan B.; Qian, Wei

    2015-01-01

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy

  5. Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Aghaei, Faranak; Tan, Maxine; Liu, Hong; Zheng, Bin, E-mail: Bin.Zheng-1@ou.edu [School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States); Hollingsworth, Alan B. [Mercy Women’s Center, Mercy Health Center, Oklahoma City, Oklahoma 73120 (United States); Qian, Wei [Department of Electrical and Computer Engineering, University of Texas, El Paso, Texas 79968 (United States)

    2015-11-15

    Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy.

  6. Computer-Aided Diagnosis of Solid Breast Lesions Using an Ultrasonic Multi-Feature Analysis Procedure

    Science.gov (United States)

    2011-01-01

    ultrasound. 1. BACKGROUND AND INTRODUCTION Breast cancer affects one of every eight women, it kills one of 29 women in the United States, and is the leading...feature analysis procedure for computer-aided diagnosis of solid breast lesions,” Ultrason Imag, 2010 (In Press). 22. C. B. Shakespeare , personal

  7. Computer-aided, single-specimen controlled bending test for fracture-kinetics measurement in ceramics

    International Nuclear Information System (INIS)

    Borovik, V.G.; Chushko, V.M.; Kovalev, S.P.

    1995-01-01

    Fracture testing of ceramics by using controlled crack growth is proposed to allow study of crack-kinetics behavior under a given loading history. A computer-aided, real-time data acquisition system improves the quality of crack-growth parameters obtained in a simple, single-specimen bend test. Several ceramic materials were tested in the present study: aluminum nitride as a linear-elastic material; and alumina and yttria-stabilized zirconia, both representative of ceramics with microstructure-dependent nonlinear fracture properties. Ambiguities in the crack-growth diagrams are discussed to show the importance of accounting for crack-growth history in correctly describing nonequilibrium fracture behavior

  8. Computer-aided global breast MR image feature analysis for prediction of tumor response to chemotherapy: performance assessment

    Science.gov (United States)

    Aghaei, Faranak; Tan, Maxine; Hollingsworth, Alan B.; Zheng, Bin; Cheng, Samuel

    2016-03-01

    Dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI) has been used increasingly in breast cancer diagnosis and assessment of cancer treatment efficacy. In this study, we applied a computer-aided detection (CAD) scheme to automatically segment breast regions depicting on MR images and used the kinetic image features computed from the global breast MR images acquired before neoadjuvant chemotherapy to build a new quantitative model to predict response of the breast cancer patients to the chemotherapy. To assess performance and robustness of this new prediction model, an image dataset involving breast MR images acquired from 151 cancer patients before undergoing neoadjuvant chemotherapy was retrospectively assembled and used. Among them, 63 patients had "complete response" (CR) to chemotherapy in which the enhanced contrast levels inside the tumor volume (pre-treatment) was reduced to the level as the normal enhanced background parenchymal tissues (post-treatment), while 88 patients had "partially response" (PR) in which the high contrast enhancement remain in the tumor regions after treatment. We performed the studies to analyze the correlation among the 22 global kinetic image features and then select a set of 4 optimal features. Applying an artificial neural network trained with the fusion of these 4 kinetic image features, the prediction model yielded an area under ROC curve (AUC) of 0.83+/-0.04. This study demonstrated that by avoiding tumor segmentation, which is often difficult and unreliable, fusion of kinetic image features computed from global breast MR images without tumor segmentation can also generate a useful clinical marker in predicting efficacy of chemotherapy.

  9. Comparison of image features calculated in different dimensions for computer-aided diagnosis of lung nodules

    Science.gov (United States)

    Xu, Ye; Lee, Michael C.; Boroczky, Lilla; Cann, Aaron D.; Borczuk, Alain C.; Kawut, Steven M.; Powell, Charles A.

    2009-02-01

    Features calculated from different dimensions of images capture quantitative information of the lung nodules through one or multiple image slices. Previously published computer-aided diagnosis (CADx) systems have used either twodimensional (2D) or three-dimensional (3D) features, though there has been little systematic analysis of the relevance of the different dimensions and of the impact of combining different dimensions. The aim of this study is to determine the importance of combining features calculated in different dimensions. We have performed CADx experiments on 125 pulmonary nodules imaged using multi-detector row CT (MDCT). The CADx system computed 192 2D, 2.5D, and 3D image features of the lesions. Leave-one-out experiments were performed using five different combinations of features from different dimensions: 2D, 3D, 2.5D, 2D+3D, and 2D+3D+2.5D. The experiments were performed ten times for each group. Accuracy, sensitivity and specificity were used to evaluate the performance. Wilcoxon signed-rank tests were applied to compare the classification results from these five different combinations of features. Our results showed that 3D image features generate the best result compared with other combinations of features. This suggests one approach to potentially reducing the dimensionality of the CADx data space and the computational complexity of the system while maintaining diagnostic accuracy.

  10. A ROC-based feature selection method for computer-aided detection and diagnosis

    Science.gov (United States)

    Wang, Songyuan; Zhang, Guopeng; Liao, Qimei; Zhang, Junying; Jiao, Chun; Lu, Hongbing

    2014-03-01

    Image-based computer-aided detection and diagnosis (CAD) has been a very active research topic aiming to assist physicians to detect lesions and distinguish them from benign to malignant. However, the datasets fed into a classifier usually suffer from small number of samples, as well as significantly less samples available in one class (have a disease) than the other, resulting in the classifier's suboptimal performance. How to identifying the most characterizing features of the observed data for lesion detection is critical to improve the sensitivity and minimize false positives of a CAD system. In this study, we propose a novel feature selection method mR-FAST that combines the minimal-redundancymaximal relevance (mRMR) framework with a selection metric FAST (feature assessment by sliding thresholds) based on the area under a ROC curve (AUC) generated on optimal simple linear discriminants. With three feature datasets extracted from CAD systems for colon polyps and bladder cancer, we show that the space of candidate features selected by mR-FAST is more characterizing for lesion detection with higher AUC, enabling to find a compact subset of superior features at low cost.

  11. Max-AUC feature selection in computer-aided detection of polyps in CT colonography.

    Science.gov (United States)

    Xu, Jian-Wu; Suzuki, Kenji

    2014-03-01

    We propose a feature selection method based on a sequential forward floating selection (SFFS) procedure to improve the performance of a classifier in computerized detection of polyps in CT colonography (CTC). The feature selection method is coupled with a nonlinear support vector machine (SVM) classifier. Unlike the conventional linear method based on Wilks' lambda, the proposed method selected the most relevant features that would maximize the area under the receiver operating characteristic curve (AUC), which directly maximizes classification performance, evaluated based on AUC value, in the computer-aided detection (CADe) scheme. We presented two variants of the proposed method with different stopping criteria used in the SFFS procedure. The first variant searched all feature combinations allowed in the SFFS procedure and selected the subsets that maximize the AUC values. The second variant performed a statistical test at each step during the SFFS procedure, and it was terminated if the increase in the AUC value was not statistically significant. The advantage of the second variant is its lower computational cost. To test the performance of the proposed method, we compared it against the popular stepwise feature selection method based on Wilks' lambda for a colonic-polyp database (25 polyps and 2624 nonpolyps). We extracted 75 morphologic, gray-level-based, and texture features from the segmented lesion candidate regions. The two variants of the proposed feature selection method chose 29 and 7 features, respectively. Two SVM classifiers trained with these selected features yielded a 96% by-polyp sensitivity at false-positive (FP) rates of 4.1 and 6.5 per patient, respectively. Experiments showed a significant improvement in the performance of the classifier with the proposed feature selection method over that with the popular stepwise feature selection based on Wilks' lambda that yielded 18.0 FPs per patient at the same sensitivity level.

  12. Computer-aided diagnosis with textural features for breast lesions in sonograms.

    Science.gov (United States)

    Chen, Dar-Ren; Huang, Yu-Len; Lin, Sheng-Hsiung

    2011-04-01

    Computer-aided diagnosis (CAD) systems provided second beneficial support reference and enhance the diagnostic accuracy. This paper was aimed to develop and evaluate a CAD with texture analysis in the classification of breast tumors for ultrasound images. The ultrasound (US) dataset evaluated in this study composed of 1020 sonograms of region of interest (ROI) subimages from 255 patients. Two-view sonogram (longitudinal and transverse views) and four different rectangular regions were utilized to analyze each tumor. Six practical textural features from the US images were performed to classify breast tumors as benign or malignant. However, the textural features always perform as a high dimensional vector; high dimensional vector is unfavorable to differentiate breast tumors in practice. The principal component analysis (PCA) was used to reduce the dimension of textural feature vector and then the image retrieval technique was performed to differentiate between benign and malignant tumors. In the experiments, all the cases were sampled with k-fold cross-validation (k=10) to evaluate the performance with receiver operating characteristic (ROC) curve. The area (A(Z)) under the ROC curve for the proposed CAD system with the specific textural features was 0.925±0.019. The classification ability for breast tumor with textural information is satisfactory. This system differentiates benign from malignant breast tumors with a good result and is therefore clinically useful to provide a second opinion. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Computer-aided diagnosis with morphological features for breast lesion on sonograms

    International Nuclear Information System (INIS)

    Huang Yu-Len; Jiang Yu-Ru; Shiu Jia-Jia; Chen Dar-Ren; Moon Woo Kyung

    2007-01-01

    Information about shape, provided by a breast tumor contour is important to physicians in making diagnostic decisions. To avoid needless biopsy and enhance the diagnostic accuracy, a computer-aided diagnosis (CAD) system can provide a second beneficial support reference. This paper aimed to evaluate the potential role of the CAD with automatic contouring and morphologic analysis in the differential of breast tumors for ultrasound (US) images. This study evaluated 118 breast lesions. The suspicious tumor contour in the digitized US image was automatically extracted by the proposed contouring algorithm. Then 20 practical morphologic features from the extracted contour were calculated and a support vector machine (SVM) classifier identified the breast tumor as benign or malignant. The area (Az) under the receiver operating characteristic (ROC) curve for the proposed CAD system was 0.91 ± 0.03. This system differentiates benign from malignant breast tumors with relative high accuracy and is therefore clinically useful to reduce patients needed for dispensable breast biopsy. (orig.)

  14. Features of undiagnosed breast cancers at screening breast MR imaging and potential utility of computer-aided evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Mirinae; Cho, Nariya; Bea, Min Sun; Koo, Hye Ryoung; Kim, Won Hwa; Lee, Su Hyun; Chu, A Jung [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-02-15

    To retrospectively evaluate the features of undiagnosed breast cancers on prior screening breast magnetic resonance (MR) images in patients who were subsequently diagnosed with breast cancer, as well as the potential utility of MR-computer-aided evaluation (CAE). Between March 2004 and May 2013, of the 72 consecutive pairs of prior negative MR images and subsequent MR images with diagnosed cancers (median interval, 32.8 months; range, 5.4-104.6 months), 36 (50%) had visible findings (mean size, 1.0 cm; range, 0.3-5.2 cm). The visible findings were divided into either actionable or under threshold groups by the blinded review by 5 radiologists. MR imaging features, reasons for missed cancer, and MR-CAE features according to actionability were evaluated. Of the 36 visible findings on prior MR images, 33.3% (12 of 36) of the lesions were determined to be actionable and 66.7% (24 of 36) were underthreshold; 85.7% (6 of 7) of masses and 31.6% (6 of 19) of non-mass enhancements were classified as actionable lesions. Mimicking physiologic enhancements (27.8%, 10 of 36) and small lesion size (27.8%, 10 of 36) were the most common reasons for missed cancer. Actionable findings tended to show more washout or plateau kinetic patterns on MR-CAE than underthreshold findings, as the 100% of actionable findings and 46.7% of underthreshold findings showed washout or plateau (p = 0.008). MR-CAE has the potential for reducing the number of undiagnosed breast cancers on screening breast MR images, the majority of which are caused by mimicking physiologic enhancements or small lesion size.

  15. Computer aided diagnosis system for Alzheimer disease using brain diffusion tensor imaging features selected by Pearson's correlation.

    Science.gov (United States)

    Graña, M; Termenon, M; Savio, A; Gonzalez-Pinto, A; Echeveste, J; Pérez, J M; Besga, A

    2011-09-20

    The aim of this paper is to obtain discriminant features from two scalar measures of Diffusion Tensor Imaging (DTI) data, Fractional Anisotropy (FA) and Mean Diffusivity (MD), and to train and test classifiers able to discriminate Alzheimer's Disease (AD) patients from controls on the basis of features extracted from the FA or MD volumes. In this study, support vector machine (SVM) classifier was trained and tested on FA and MD data. Feature selection is done computing the Pearson's correlation between FA or MD values at voxel site across subjects and the indicative variable specifying the subject class. Voxel sites with high absolute correlation are selected for feature extraction. Results are obtained over an on-going study in Hospital de Santiago Apostol collecting anatomical T1-weighted MRI volumes and DTI data from healthy control subjects and AD patients. FA features and a linear SVM classifier achieve perfect accuracy, sensitivity and specificity in several cross-validation studies, supporting the usefulness of DTI-derived features as an image-marker for AD and to the feasibility of building Computer Aided Diagnosis systems for AD based on them. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. A novel computer-aided diagnosis system for breast MRI based on feature selection and ensemble learning.

    Science.gov (United States)

    Lu, Wei; Li, Zhe; Chu, Jinghui

    2017-04-01

    Breast cancer is a common cancer among women. With the development of modern medical science and information technology, medical imaging techniques have an increasingly important role in the early detection and diagnosis of breast cancer. In this paper, we propose an automated computer-aided diagnosis (CADx) framework for magnetic resonance imaging (MRI). The scheme consists of an ensemble of several machine learning-based techniques, including ensemble under-sampling (EUS) for imbalanced data processing, the Relief algorithm for feature selection, the subspace method for providing data diversity, and Adaboost for improving the performance of base classifiers. We extracted morphological, various texture, and Gabor features. To clarify the feature subsets' physical meaning, subspaces are built by combining morphological features with each kind of texture or Gabor feature. We tested our proposal using a manually segmented Region of Interest (ROI) data set, which contains 438 images of malignant tumors and 1898 images of normal tissues or benign tumors. Our proposal achieves an area under the ROC curve (AUC) value of 0.9617, which outperforms most other state-of-the-art breast MRI CADx systems. Compared with other methods, our proposal significantly reduces the false-positive classification rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Computer-Aided Diagnosis for Breast Ultrasound Using Computerized BI-RADS Features and Machine Learning Methods.

    Science.gov (United States)

    Shan, Juan; Alam, S Kaisar; Garra, Brian; Zhang, Yingtao; Ahmed, Tahira

    2016-04-01

    This work identifies effective computable features from the Breast Imaging Reporting and Data System (BI-RADS), to develop a computer-aided diagnosis (CAD) system for breast ultrasound. Computerized features corresponding to ultrasound BI-RADs categories were designed and tested using a database of 283 pathology-proven benign and malignant lesions. Features were selected based on classification performance using a "bottom-up" approach for different machine learning methods, including decision tree, artificial neural network, random forest and support vector machine. Using 10-fold cross-validation on the database of 283 cases, the highest area under the receiver operating characteristic (ROC) curve (AUC) was 0.84 from a support vector machine with 77.7% overall accuracy; the highest overall accuracy, 78.5%, was from a random forest with the AUC 0.83. Lesion margin and orientation were optimum features common to all of the different machine learning methods. These features can be used in CAD systems to help distinguish benign from worrisome lesions. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  18. Assessment of Itakura Distance as a valuable feature for computer-aided classification of sleep stages.

    Science.gov (United States)

    Ebrahimi, F; Mikaili, M; Estrada, E; Nazeran, H

    2007-01-01

    Staging and detection of various states of sleep derived from EEG and other biomedical signals have proven to be very helpful in diagnosis, prognosis and remedy of various sleep related disorders. The time consuming and costly process of visual scoring of sleep stages by a specialist has always motivated researchers to develop an automatic sleep scoring system and the first step toward achieving this task is finding discriminating characteristics (or features) for each stage. A vast variety of these features and methods have been investigated in the sleep literature with different degrees of success. In this study, we investigated the performance of a newly introduced measure: the Itakura Distance (ID), as a similarity measure between EEG and EOG signals. This work demonstrated and further confirmed the outcomes of our previous research that the Itakura Distance serves as a valuable similarity measure to differentiate between different sleep stages.

  19. Computer Aided Quantification of Pathological Features for Flexor Tendon Pulleys on Microscopic Images

    Directory of Open Access Journals (Sweden)

    Yung-Chun Liu

    2013-01-01

    Full Text Available Quantifying the pathological features of flexor tendon pulleys is essential for grading the trigger finger since it provides clinicians with objective evidence derived from microscopic images. Although manual grading is time consuming and dependent on the observer experience, there is a lack of image processing methods for automatically extracting pulley pathological features. In this paper, we design and develop a color-based image segmentation system to extract the color and shape features from pulley microscopic images. Two parameters which are the size ratio of abnormal tissue regions and the number ratio of abnormal nuclei are estimated as the pathological progression indices. The automatic quantification results show clear discrimination among different levels of diseased pulley specimens which are prone to misjudgments for human visual inspection. The proposed system provides a reliable and automatic way to obtain pathological parameters instead of manual evaluation which is with intra- and interoperator variability. Experiments with 290 microscopic images from 29 pulley specimens show good correspondence with pathologist expectations. Hence, the proposed system has great potential for assisting clinical experts in routine histopathological examinations.

  20. Computer-aided detection of renal calculi from noncontrast CT images using TV-flow and MSER features

    Science.gov (United States)

    Liu, Jianfei; Wang, Shijun; Turkbey, Evrim B.; Linguraru, Marius George; Yao, Jianhua; Summers, Ronald M.

    2015-01-01

    Purpose: Renal calculi are common extracolonic incidental findings on computed tomographic colonography (CTC). This work aims to develop a fully automated computer-aided diagnosis system to accurately detect renal calculi on CTC images. Methods: The authors developed a total variation (TV) flow method to reduce image noise within the kidneys while maintaining the characteristic appearance of renal calculi. Maximally stable extremal region (MSER) features were then calculated to robustly identify calculi candidates. Finally, the authors computed texture and shape features that were imported to support vector machines for calculus classification. The method was validated on a dataset of 192 patients and compared to a baseline approach that detects calculi by thresholding. The authors also compared their method with the detection approaches using anisotropic diffusion and nonsmoothing. Results: At a false positive rate of 8 per patient, the sensitivities of the new method and the baseline thresholding approach were 69% and 35% (p < 1e − 3) on all calculi from 1 to 433 mm3 in the testing dataset. The sensitivities of the detection methods using anisotropic diffusion and nonsmoothing were 36% and 0%, respectively. The sensitivity of the new method increased to 90% if only larger and more clinically relevant calculi were considered. Conclusions: Experimental results demonstrated that TV-flow and MSER features are efficient means to robustly and accurately detect renal calculi on low-dose, high noise CTC images. Thus, the proposed method can potentially improve diagnosis. PMID:25563255

  1. Computer aided product design

    DEFF Research Database (Denmark)

    Constantinou, Leonidas; Bagherpour, Khosrow; Gani, Rafiqul

    1996-01-01

    A general methodology for Computer Aided Product Design (CAPD) with specified property constraints which is capable of solving a large range of problems is presented. The methodology employs the group contribution approach, generates acyclic, cyclic and aromatic compounds of various degrees......-liquid equilibria (LLE), solid-liquid equilibria (SLE) and gas solubility. Finally, a computer program based on the extended methodology has been developed and the results from five case studies highlighting various features of the methodology are presented....

  2. Computer-aided classification of lesions by means of their kinetic signatures in dynamic contrast-enhanced MR images

    Science.gov (United States)

    Twellmann, Thorsten; ter Haar Romeny, Bart

    2008-03-01

    The kinetic characteristics of tissue in dynamic contrast-enhanced magnetic resonance imaging data are an important source of information for the differentiation of benign and malignant lesions. Kinetic curves measured for each lesion voxel allow to infer information about the state of the local tissue. As a whole, they reflect the heterogeneity of the vascular structure within a lesion, an important criterion for the preoperative classification of lesions. Current clinical practice in analysis of tissue kinetics however is mainly based on the evaluation of the "most-suspect curve", which is only related to a small, manually or semi-automatically selected region-of-interest within a lesion and does not reflect any information about tissue heterogeneity. We propose a new method which exploits the full range of kinetic information for the automatic classification of lesions. Instead of breaking down the large amount of kinetic information to a single curve, each lesion is considered as a probability distribution in a space of kinetic features, efficiently represented by its kinetic signature obtained by adaptive vector quantization of the corresponding kinetic curves. Dissimilarity of two signatures can be objectively measured using the Mallows distance, which is a metric defined on probability distributions. The embedding of this metric in a suitable kernel function enables us to employ modern kernel-based machine learning techniques for the classification of signatures. In a study considering 81 breast lesions, the proposed method yielded an A z value of 0.89+/-0.01 for the discrimination of benign and malignant lesions in a nested leave-one-lesion-out evaluation setting.

  3. Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

    International Nuclear Information System (INIS)

    Masotti, Matteo; Lanconelli, Nico; Campanini, Renato

    2009-01-01

    In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with their gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks

  4. Specific features of organizng the computer-aided design of radio-electronic equipment for electrophysical facilities

    International Nuclear Information System (INIS)

    Mozin, I.V.; Vasil'ev, M.P.

    1985-01-01

    Problems of developing systems for computer-aided design (CAD) of radioelectronic equipment for large electrophysical facilities such as charged particle accelerators of new generation are discussed. The PLATA subsystem representing a part of CAD and used for printed circuit design is described. The subsystem PLATA is utilized to design, on the average, up to 150 types of circuits a year, 100-120 of which belong to circuits of increased complexity. In this case labour productivity of a designer at documentation increases almost two times

  5. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    Science.gov (United States)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-09-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 × 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver ( p fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  6. Statistical-techniques-based computer-aided diagnosis (CAD) using texture feature analysis: application in computed tomography (CT) imaging to fatty liver disease

    International Nuclear Information System (INIS)

    Chung, Woon-Kwan; Park, Hyong-Hu; Im, In-Chul; Lee, Jae-Seung; Goo, Eun-Hoe; Dong, Kyung-Rae

    2012-01-01

    This paper proposes a computer-aided diagnosis (CAD) system based on texture feature analysis and statistical wavelet transformation technology to diagnose fatty liver disease with computed tomography (CT) imaging. In the target image, a wavelet transformation was performed for each lesion area to set the region of analysis (ROA, window size: 50 x 50 pixels) and define the texture feature of a pixel. Based on the extracted texture feature values, six parameters (average gray level, average contrast, relative smoothness, skewness, uniformity, and entropy) were determined to calculate the recognition rate for a fatty liver. In addition, a multivariate analysis of the variance (MANOVA) method was used to perform a discriminant analysis to verify the significance of the extracted texture feature values and the recognition rate for a fatty liver. According to the results, each texture feature value was significant for a comparison of the recognition rate for a fatty liver (p < 0.05). Furthermore, the F-value, which was used as a scale for the difference in recognition rates, was highest in the average gray level, relatively high in the skewness and the entropy, and relatively low in the uniformity, the relative smoothness and the average contrast. The recognition rate for a fatty liver had the same scale as that for the F-value, showing 100% (average gray level) at the maximum and 80% (average contrast) at the minimum. Therefore, the recognition rate is believed to be a useful clinical value for the automatic detection and computer-aided diagnosis (CAD) using the texture feature value. Nevertheless, further study on various diseases and singular diseases will be needed in the future.

  7. Computer-aided assessment of breast density: comparison of supervised deep learning and feature-based statistical learning

    Science.gov (United States)

    Li, Songfeng; Wei, Jun; Chan, Heang-Ping; Helvie, Mark A.; Roubidoux, Marilyn A.; Lu, Yao; Zhou, Chuan; Hadjiiski, Lubomir M.; Samala, Ravi K.

    2018-01-01

    Breast density is one of the most significant factors that is associated with cancer risk. In this study, our purpose was to develop a supervised deep learning approach for automated estimation of percentage density (PD) on digital mammograms (DMs). The input ‘for processing’ DMs was first log-transformed, enhanced by a multi-resolution preprocessing scheme, and subsampled to a pixel size of 800 µm  ×  800 µm from 100 µm  ×  100 µm. A deep convolutional neural network (DCNN) was trained to estimate a probability map of breast density (PMD) by using a domain adaptation resampling method. The PD was estimated as the ratio of the dense area to the breast area based on the PMD. The DCNN approach was compared to a feature-based statistical learning approach. Gray level, texture and morphological features were extracted and a least absolute shrinkage and selection operator was used to combine the features into a feature-based PMD. With approval of the Institutional Review Board, we retrospectively collected a training set of 478 DMs and an independent test set of 183 DMs from patient files in our institution. Two experienced mammography quality standards act radiologists interactively segmented PD as the reference standard. Ten-fold cross-validation was used for model selection and evaluation with the training set. With cross-validation, DCNN obtained a Dice’s coefficient (DC) of 0.79  ±  0.13 and Pearson’s correlation (r) of 0.97, whereas feature-based learning obtained DC  =  0.72  ±  0.18 and r  =  0.85. For the independent test set, DCNN achieved DC  =  0.76  ±  0.09 and r  =  0.94, while feature-based learning achieved DC  =  0.62  ±  0.21 and r  =  0.75. Our DCNN approach was significantly better and more robust than the feature-based learning approach for automated PD estimation on DMs, demonstrating its potential use for automated density reporting as

  8. Computer-aided assessment of breast density: comparison of supervised deep learning and feature-based statistical learning.

    Science.gov (United States)

    Li, Songfeng; Wei, Jun; Chan, Heang-Ping; Helvie, Mark A; Roubidoux, Marilyn A; Lu, Yao; Zhou, Chuan; Hadjiiski, Lubomir M; Samala, Ravi K

    2018-01-09

    Breast density is one of the most significant factors that is associated with cancer risk. In this study, our purpose was to develop a supervised deep learning approach for automated estimation of percentage density (PD) on digital mammograms (DMs). The input 'for processing' DMs was first log-transformed, enhanced by a multi-resolution preprocessing scheme, and subsampled to a pixel size of 800 µm  ×  800 µm from 100 µm  ×  100 µm. A deep convolutional neural network (DCNN) was trained to estimate a probability map of breast density (PMD) by using a domain adaptation resampling method. The PD was estimated as the ratio of the dense area to the breast area based on the PMD. The DCNN approach was compared to a feature-based statistical learning approach. Gray level, texture and morphological features were extracted and a least absolute shrinkage and selection operator was used to combine the features into a feature-based PMD. With approval of the Institutional Review Board, we retrospectively collected a training set of 478 DMs and an independent test set of 183 DMs from patient files in our institution. Two experienced mammography quality standards act radiologists interactively segmented PD as the reference standard. Ten-fold cross-validation was used for model selection and evaluation with the training set. With cross-validation, DCNN obtained a Dice's coefficient (DC) of 0.79  ±  0.13 and Pearson's correlation (r) of 0.97, whereas feature-based learning obtained DC  =  0.72  ±  0.18 and r  =  0.85. For the independent test set, DCNN achieved DC  =  0.76  ±  0.09 and r  =  0.94, while feature-based learning achieved DC  =  0.62  ±  0.21 and r  =  0.75. Our DCNN approach was significantly better and more robust than the feature-based learning approach for automated PD estimation on DMs, demonstrating its potential use for automated density reporting as well as

  9. Computer aided safety analysis

    International Nuclear Information System (INIS)

    1988-05-01

    The document reproduces 20 selected papers from the 38 papers presented at the Technical Committee/Workshop on Computer Aided Safety Analysis organized by the IAEA in co-operation with the Institute of Atomic Energy in Otwock-Swierk, Poland on 25-29 May 1987. A separate abstract was prepared for each of these 20 technical papers. Refs, figs and tabs

  10. Computer aided design

    International Nuclear Information System (INIS)

    Barache, J.M.; Beltranda, G.; Blanc, P.

    1987-01-01

    In order to ensure that the data transmitted to the managment system is of the required quality and consistent with the general control command protocols, computer aided design (CAD) was employed for level N4. One describes the use of CAD for the control system of N4 [fr

  11. Computer aided drug design

    Science.gov (United States)

    Jain, A.

    2017-08-01

    Computer based method can help in discovery of leads and can potentially eliminate chemical synthesis and screening of many irrelevant compounds, and in this way, it save time as well as cost. Molecular modeling systems are powerful tools for building, visualizing, analyzing and storing models of complex molecular structure that can help to interpretate structure activity relationship. The use of various techniques of molecular mechanics and dynamics and software in Computer aided drug design along with statistics analysis is powerful tool for the medicinal chemistry to synthesis therapeutic and effective drugs with minimum side effect.

  12. Computer aided control engineering

    DEFF Research Database (Denmark)

    Szymkat, Maciej; Ravn, Ole

    1997-01-01

    Current developments in the field of Computer Aided Control Engineering (CACE) have a visible impact on the design methodologies and the structure of the software tools supporting them. Today control engineers has at their disposal libraries, packages or programming environments that may...... in CACE enhancing efficient flow of information between the tools supporting the following phases of the design process. In principle, this flow has to be two-way, and more or less automated, in order to enable the engineer to observe the propagation of the particular design decisions taken at various...... levels.The major conclusions of the paper are related with identifying the factors affecting the software tool integration in a way needed to facilitate design "inter-phase" communication. These are: standard application interfaces, dynamic data exchange mechanisms, code generation techniques and general...

  13. Software For Computer-Aided Design Of Control Systems

    Science.gov (United States)

    Wette, Matthew

    1994-01-01

    Computer Aided Engineering System (CAESY) software developed to provide means to evaluate methods for dealing with users' needs in computer-aided design of control systems. Interpreter program for performing engineering calculations. Incorporates features of both Ada and MATLAB. Designed to be flexible and powerful. Includes internally defined functions, procedures and provides for definition of functions and procedures by user. Written in C language.

  14. Computer-aided system design

    Science.gov (United States)

    Walker, Carrie K.

    1991-01-01

    A technique has been developed for combining features of a systems architecture design and assessment tool and a software development tool. This technique reduces simulation development time and expands simulation detail. The Architecture Design and Assessment System (ADAS), developed at the Research Triangle Institute, is a set of computer-assisted engineering tools for the design and analysis of computer systems. The ADAS system is based on directed graph concepts and supports the synthesis and analysis of software algorithms mapped to candidate hardware implementations. Greater simulation detail is provided by the ADAS functional simulator. With the functional simulator, programs written in either Ada or C can be used to provide a detailed description of graph nodes. A Computer-Aided Software Engineering tool developed at the Charles Stark Draper Laboratory (CSDL CASE) automatically generates Ada or C code from engineering block diagram specifications designed with an interactive graphical interface. A technique to use the tools together has been developed, which further automates the design process.

  15. CAESY - COMPUTER AIDED ENGINEERING SYSTEM

    Science.gov (United States)

    Wette, M. R.

    1994-01-01

    Many developers of software and algorithms for control system design have recognized that current tools have limits in both flexibility and efficiency. Many forces drive the development of new tools including the desire to make complex system modeling design and analysis easier and the need for quicker turnaround time in analysis and design. Other considerations include the desire to make use of advanced computer architectures to help in control system design, adopt new methodologies in control, and integrate design processes (e.g., structure, control, optics). CAESY was developed to provide a means to evaluate methods for dealing with user needs in computer-aided control system design. It is an interpreter for performing engineering calculations and incorporates features of both Ada and MATLAB. It is designed to be reasonably flexible and powerful. CAESY includes internally defined functions and procedures, as well as user defined ones. Support for matrix calculations is provided in the same manner as MATLAB. However, the development of CAESY is a research project, and while it provides some features which are not found in commercially sold tools, it does not exhibit the robustness that many commercially developed tools provide. CAESY is written in C-language for use on Sun4 series computers running SunOS 4.1.1 and later. The program is designed to optionally use the LAPACK math library. The LAPACK math routines are available through anonymous ftp from research.att.com. CAESY requires 4Mb of RAM for execution. The standard distribution medium is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. CAESY was developed in 1993 and is a copyrighted work with all copyright vested in NASA.

  16. Computer-Aided Modeling Framework

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    Models are playing important roles in design and analysis of chemicals based products and the processes that manufacture them. Computer-aided methods and tools have the potential to reduce the number of experiments, which can be expensive and time consuming, and there is a benefit of working...... development and application. The proposed work is a part of the project for development of methods and tools that will allow systematic generation, analysis and solution of models for various objectives. It will use the computer-aided modeling framework that is based on a modeling methodology, which combines....... In this contribution, the concept of template-based modeling is presented and application is highlighted for the specific case of catalytic membrane fixed bed models. The modeling template is integrated in a generic computer-aided modeling framework. Furthermore, modeling templates enable the idea of model reuse...

  17. Computer-aided diagnosis for phase-contrast X-ray computed tomography: quantitative characterization of human patellar cartilage with high-dimensional geometric features.

    Science.gov (United States)

    Nagarajan, Mahesh B; Coan, Paola; Huber, Markus B; Diemoz, Paul C; Glaser, Christian; Wismüller, Axel

    2014-02-01

    Phase-contrast computed tomography (PCI-CT) has shown tremendous potential as an imaging modality for visualizing human cartilage with high spatial resolution. Previous studies have demonstrated the ability of PCI-CT to visualize (1) structural details of the human patellar cartilage matrix and (2) changes to chondrocyte organization induced by osteoarthritis. This study investigates the use of high-dimensional geometric features in characterizing such chondrocyte patterns in the presence or absence of osteoarthritic damage. Geometrical features derived from the scaling index method (SIM) and statistical features derived from gray-level co-occurrence matrices were extracted from 842 regions of interest (ROI) annotated on PCI-CT images of ex vivo human patellar cartilage specimens. These features were subsequently used in a machine learning task with support vector regression to classify ROIs as healthy or osteoarthritic; classification performance was evaluated using the area under the receiver-operating characteristic curve (AUC). SIM-derived geometrical features exhibited the best classification performance (AUC, 0.95 ± 0.06) and were most robust to changes in ROI size. These results suggest that such geometrical features can provide a detailed characterization of the chondrocyte organization in the cartilage matrix in an automated and non-subjective manner, while also enabling classification of cartilage as healthy or osteoarthritic with high accuracy. Such features could potentially serve as imaging markers for evaluating osteoarthritis progression and its response to different therapeutic intervention strategies.

  18. Non-invasive Characterization of the Histopathologic Features of Pulmonary Nodules of the Lung Adenocarcinoma Spectrum using Computer Aided Nodule Assessment and Risk Yield (CANARY) – a Pilot Study

    Science.gov (United States)

    Maldonado, Fabien; Boland, Jennifer M.; Raghunath, Sushravya; Aubry, Marie Christine; Bartholmai, Brian J.; deAndrade, Mariza; Hartman, Thomas E.; Karwoski, Ronald A.; Rajagopalan, Srinivasan; Sykes, Anne-Marie; Yang, Ping; Yi, Eunhee S.; Robb, Richard A.; Peikert, Tobias

    2013-01-01

    Introduction Pulmonary nodules of the adenocarcinoma spectrum are characterized by distinctive morphological and radiological features and variable prognosis. Non-invasive high-resolution computed-tomography (HRCT)-based risk stratification tools are needed to individualize their management. Methods Radiological measurements of histopathologic tissue invasion were developed in a training set of 54 pulmonary nodules of the adenocarcinoma spectrum and validated in 86 consecutively resected nodules. Nodules were isolated and characterized by computer-aided analysis and data were analyzed by Spearman correlation, sensitivity, specificity as well as the positive and negative predictive values. Results Computer Aided Nodule Assessment and Risk Yield (CANARY) can non-invasively characterize pulmonary nodules of the adenocarcinoma spectrum. Unsupervised clustering analysis of HRCT data identified 9 unique exemplars representing the basic radiologic building blocks of these lesions. The exemplar distribution within each nodule correlated well with the proportion of histologic tissue invasion, Spearman R=0.87,p < 0.0001 and 0.89,p < 0.0001 for the training and the validation set, respectively. Clustering of the exemplars in three-dimensional space corresponding to tissue invasion and lepidic growth was used to develop a CANARY decision algorithm, which successfully categorized these pulmonary nodules as “aggressive” (invasive adenocarcinoma) or “indolent” (adenocarcinoma in situ and minimally invasive adenocarcinoma). Sensitivity, specificity, positive predictive value and negative predictive value of this approach for the detection of “aggressive” lesions were 95.4%, 96.8%, 95.4% and 96.8%, respectively in the training set and 98.7%, 63.6%, 94.9% and 87.5%, respectively in the validation set. Conclusion CANARY represents a promising tool to non-invasively risk stratify pulmonary nodules of the adenocarcinoma spectrum. PMID:23486265

  19. Applicability of computer-aided comprehensive tool (LINDA: LINeament Detection and Analysis) and shaded digital elevation model for characterizing and interpreting morphotectonic features from lineaments

    Science.gov (United States)

    Masoud, Alaa; Koike, Katsuaki

    2017-09-01

    Detection and analysis of linear features related to surface and subsurface structures have been deemed necessary in natural resource exploration and earth surface instability assessment. Subjectivity in choosing control parameters required in conventional methods of lineament detection may cause unreliable results. To reduce this ambiguity, we developed LINDA (LINeament Detection and Analysis), an integrated tool with graphical user interface in Visual Basic. This tool automates processes of detection and analysis of linear features from grid data of topography (digital elevation model; DEM), gravity and magnetic surfaces, as well as data from remote sensing imagery. A simple interface with five display windows forms a user-friendly interactive environment. The interface facilitates grid data shading, detection and grouping of segments, lineament analyses for calculating strike and dip and estimating fault type, and interactive viewing of lineament geometry. Density maps of the center and intersection points of linear features (segments and lineaments) are also included. A systematic analysis of test DEMs and Landsat 7 ETM+ imagery datasets in the North and South Eastern Deserts of Egypt is implemented to demonstrate the capability of LINDA and correct use of its functions. Linear features from the DEM are superior to those from the imagery in terms of frequency, but both linear features agree with location and direction of V-shaped valleys and dykes and reference fault data. Through the case studies, LINDA applicability is demonstrated to highlight dominant structural trends, which can aid understanding of geodynamic frameworks in any region.

  20. Computer-Aided Parts Estimation

    OpenAIRE

    Cunningham, Adam; Smart, Robert

    1993-01-01

    In 1991, Ford Motor Company began deployment of CAPE (computer-aided parts estimating system), a highly advanced knowledge-based system designed to generate, evaluate, and cost automotive part manufacturing plans. cape is engineered on an innovative, extensible, declarative process-planning and estimating knowledge representation language, which underpins the cape kernel architecture. Many manufacturing processes have been modeled to date, but eventually every significant process in motor veh...

  1. Computer aids for plant operators

    International Nuclear Information System (INIS)

    Joly, J.P.

    1992-01-01

    For some time, particularly since the TMI accident, nuclear power plant operators have been aware of the difficulties involved in diagnosing accidents and returning plants to their stable, safe operating mode. There are various possible solutions to these problems: improve control organization during accident situations, rewrite control procedures, integrate safety engineers in shifts, improve control rooms, and implement additional computer aids. The purpose of this presentation is to describe the efforts undertaken by EDF over the last few years in this field

  2. Computer-Aided Facilities Management Systems (CAFM).

    Science.gov (United States)

    Cyros, Kreon L.

    Computer-aided facilities management (CAFM) refers to a collection of software used with increasing frequency by facilities managers. The six major CAFM components are discussed with respect to their usefulness and popularity in facilities management applications: (1) computer-aided design; (2) computer-aided engineering; (3) decision support…

  3. Computer-aided translation tools

    DEFF Research Database (Denmark)

    Christensen, Tina Paulsen; Schjoldager, Anne

    2016-01-01

    in Denmark is rather high in general, but limited in the case of machine translation (MT) tools: While most TSPs use translation-memory (TM) software, often in combination with a terminology management system (TMS), only very few have implemented MT, which is criticised for its low quality output, especially......The paper reports on a questionnaire survey from 2013 of the uptake and use of computer-aided translation (CAT) tools by Danish translation service providers (TSPs) and discusses how these tools appear to have impacted on the Danish translation industry. According to our results, the uptake...

  4. Computer aided analysis of disturbances

    International Nuclear Information System (INIS)

    Baldeweg, F.; Lindner, A.

    1986-01-01

    Computer aided analysis of disturbances and the prevention of failures (diagnosis and therapy control) in technological plants belong to the most important tasks of process control. Research in this field is very intensive due to increasing requirements to security and economy of process control and due to a remarkable increase of the efficiency of digital electronics. This publication concerns with analysis of disturbances in complex technological plants, especially in so called high risk processes. The presentation emphasizes theoretical concept of diagnosis and therapy control, modelling of the disturbance behaviour of the technological process and the man-machine-communication integrating artificial intelligence methods, e.g., expert system approach. Application is given for nuclear power plants. (author)

  5. Computer-aided instruction system

    International Nuclear Information System (INIS)

    Teneze, Jean Claude

    1968-01-01

    This research thesis addresses the use of teleprocessing and time sharing by the RAX IBM system and the possibility to introduce a dialog with the machine to develop an application in which the computer plays the role of a teacher for different pupils at the same time. Two operating modes are thus exploited: a teacher-mode and a pupil-mode. The developed CAI (computer-aided instruction) system comprises a checker to check the course syntax in teacher-mode, a translator to trans-code the course written in teacher-mode into a form which can be processes by the execution programme, and the execution programme which presents the course in pupil-mode

  6. Computer aided safety analysis 1989

    International Nuclear Information System (INIS)

    1990-04-01

    The meeting was conducted in a workshop style, to encourage involvement of all participants during the discussions. Forty-five (45) experts from 19 countries, plus 22 experts from the GDR participated in the meeting. A list of participants can be found at the end of this volume. Forty-two (42) papers were presented and discussed during the meeting. Additionally an open discussion was held on the possible directions of the IAEA programme on Computer Aided Safety Analysis. A summary of the conclusions of these discussions is presented in the publication. The remainder of this proceedings volume comprises the transcript of selected technical papers (22) presented in the meeting. It is the intention of the IAEA that the publication of these proceedings will extend the benefits of the discussions held during the meeting to a larger audience throughout the world. The Technical Committee/Workshop on Computer Aided Safety Analysis was organized by the IAEA in cooperation with the National Board for Safety and Radiological Protection (SAAS) of the German Democratic Republic in Berlin. The purpose of the meeting was to provide an opportunity for discussions on experiences in the use of computer codes used for safety analysis of nuclear power plants. In particular it was intended to provide a forum for exchange of information among experts using computer codes for safety analysis under the Technical Cooperation Programme on Safety of WWER Type Reactors (RER/9/004) and other experts throughout the world. A separate abstract was prepared for each of the 22 selected papers. Refs, figs tabs and pictures

  7. Integrated computer aided design simulation and manufacture

    OpenAIRE

    Diko, Faek

    1989-01-01

    Computer Aided Design (CAD) and Computer Aided Manufacture (CAM) have been investigated and developed since twenty years as standalone systems. A large number of very powerful but independent packages have been developed for Computer Aided Design,Aanlysis and Manufacture. However, in most cases these packages have poor facility for communicating with other packages. Recently attempts have been made to develop integrated CAD/CAM systems and many software companies a...

  8. Computer Aided Battery Engineering Consortium

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Ahmad

    2016-06-07

    A multi-national lab collaborative team was assembled that includes experts from academia and industry to enhance recently developed Computer-Aided Battery Engineering for Electric Drive Vehicles (CAEBAT)-II battery crush modeling tools and to develop microstructure models for electrode design - both computationally efficient. Task 1. The new Multi-Scale Multi-Domain model framework (GH-MSMD) provides 100x to 1,000x computation speed-up in battery electrochemical/thermal simulation while retaining modularity of particles and electrode-, cell-, and pack-level domains. The increased speed enables direct use of the full model in parameter identification. Task 2. Mechanical-electrochemical-thermal (MECT) models for mechanical abuse simulation were simultaneously coupled, enabling simultaneous modeling of electrochemical reactions during the short circuit, when necessary. The interactions between mechanical failure and battery cell performance were studied, and the flexibility of the model for various batteries structures and loading conditions was improved. Model validation is ongoing to compare with test data from Sandia National Laboratories. The ABDT tool was established in ANSYS. Task 3. Microstructural modeling was conducted to enhance next-generation electrode designs. This 3- year project will validate models for a variety of electrodes, complementing Advanced Battery Research programs. Prototype tools have been developed for electrochemical simulation and geometric reconstruction.

  9. Computer aided fault tree synthesis

    International Nuclear Information System (INIS)

    Poucet, A.

    1983-01-01

    Nuclear as well as non-nuclear organisations are showing during the past few years a growing interest in the field of reliability analysis. This urges for the development of powerful, state of the art methods and computer codes for performing such analysis on complex systems. In this report an interactive, computer aided approach is discussed, based on the well known fault tree technique. The time consuming and difficut task of manually constructing a system model (one or more fault trees) is replaced by an efficient interactive procedure in which the flexibility and the learning process inherent to the manual approach are combined with the accuracy in the modelling and the speed of the fully automatical approach. The method presented is based upon the use of a library containing component models. The possibility of setting up a standard library of models of general use and the link with a data collection system are discussed. The method has been implemented in the CAFTS-SALP software package which is described shortly in the report

  10. Computer-aided reduction of plasma data

    International Nuclear Information System (INIS)

    Shariati, S.

    1984-01-01

    Poor signal-to-noise ratios and the non-linear characteristics of the data obtained by most plasma diagnostic equipment makes computer-aided data handling a desirable feature in plasma laboratories. The Lecroy 3500-SA32 signal analyzer is used as the data handling system in this work. The performance of the Lecroy 3500-SA32 signal analyzer, used for recording and reducing the plasma data under the noisy environment of the laboratory, is reported. The data characteristics and software programs are discussed for three types of plasma diagnostic equipment: 1) Langmuir Probes; 2) Charge Exchange Neutral Energy Analyzers; 3) Retarding Potential Energy Analyzers. In order to protect the computer internal circuitry and to have satisfactory data acquisition and handling, methods for dealing with the noisy environment, including stray magnetic fields, RF radiation, and transient spikes on power lines, are also developed. Three computer programs are included which obtain an iterated best fit of experimental data to the corresponding analytical expressions for each case. The new data handling system enables the user to do a real-time analysis of data by using the interactive features of the Lecroy 3500-SA32 system

  11. CAT -- computer aided testing for resonant inspection

    International Nuclear Information System (INIS)

    Foley, David K.

    1998-01-01

    Application of computer technology relates to inspection and quality control. The computer aided testing (CAT) can be used to analyze various NDT technologies, such as eddy current, ultrasonics, and resonant inspection

  12. Prerequisites for Computer-Aided Cognitive Rehabilitation.

    Science.gov (United States)

    Legrand, Colette

    1989-01-01

    This paper describes computer-aided cognitive rehabilitation for mentally deficient persons. It lists motor, cognitive, emotional, and educational prerequisites to such rehabilitation and states advantages and disadvantages in using the prerequisites. (JDD)

  13. Computer aided design for the nuclear industry

    International Nuclear Information System (INIS)

    Basson, Keith

    1986-01-01

    The paper concerns the new computer aided design (CAD) centre for the United Kingdom nuclear industry, and its applications. A description of the CAD system is given, including the current projects at the CAD centre. Typical applications of the 3D CAD plant based models, stress analysis studies, and the extraction of data from CAD drawings to produce associated documentation, are all described. Future developments using computer aided design systems are also considered. (U.K.)

  14. Remote handling prospects. Computer aided remote handling

    International Nuclear Information System (INIS)

    Vertut, J.

    1984-01-01

    Mechanical manipulators, electrical control manipulators and computer aided manipulators were successively developed. The aim of computer aided manipulators is the realization of complex or tricky job in adverse environment but man is required for non routine work or for situation in evolution. French effort is developed in the frame of the project automation and advanced robotics and new problems have to be solved particularly at the interface man/machine [fr

  15. Intelligent computer-aided training and tutoring

    Science.gov (United States)

    Loftin, R. Bowen; Savely, Robert T.

    1991-01-01

    Specific autonomous training systems based on artificial intelligence technology for use by NASA astronauts, flight controllers, and ground-based support personnel that demonstrate an alternative to current training systems are described. In addition to these specific systems, the evolution of a general architecture for autonomous intelligent training systems that integrates many of the features of traditional training programs with artificial intelligence techniques is presented. These Intelligent Computer-Aided Training (ICAT) systems would provide, for the trainee, much of the same experience that could be gained from the best on-the-job training. By integrating domain expertise with a knowledge of appropriate training methods, an ICAT session should duplicate, as closely as possible, the trainee undergoing on-the-job training in the task environment, benefitting from the full attention of a task expert who is also an expert trainer. Thus, the philosophy of the ICAT system is to emulate the behavior of an experienced individual devoting his full time and attention to the training of a novice - proposing challenging training scenarios, monitoring and evaluating the actions of the trainee, providing meaningful comments in response to trainee errors, responding to trainee requests for information, giving hints (if appropriate), and remembering the strengths and weaknesses displayed by the trainee so that appropriate future exercises can be designed.

  16. Computer aided information system for a PWR

    International Nuclear Information System (INIS)

    Vaidian, T.A.; Karmakar, G.; Rajagopal, R.; Shankar, V.; Patil, R.K.

    1994-01-01

    The computer aided information system (CAIS) is designed with a view to improve the performance of the operator. CAIS assists the plant operator in an advisory and support role, thereby reducing the workload level and potential human errors. The CAIS as explained here has been designed for a PWR type KLT- 40 used in Floating Nuclear Power Stations (FNPS). However the underlying philosophy evolved in designing the CAIS can be suitably adopted for other type of nuclear power plants too (BWR, PHWR). Operator information is divided into three broad categories: a) continuously available information b) automatically available information and c) on demand information. Two in number touch screens are provided on the main control panel. One is earmarked for continuously available information and the other is dedicated for automatically available information. Both the screens can be used at the operator's discretion for on-demand information. Automatically available information screen overrides the on-demand information screens. In addition to the above, CAIS has the features of event sequence recording, disturbance recording and information documentation. CAIS design ensures that the operator is not overburdened with excess and unnecessary information, but at the same time adequate and well formatted information is available. (author). 5 refs., 4 figs

  17. Novel Kinds of Random Access Memory and New Vulnerabilities of Computer Aids based on Them

    Directory of Open Access Journals (Sweden)

    Alexander Mihaylovich Korotin

    2014-09-01

    Full Text Available The article discusses vulnerabilities of computer aids based on existing RAM and mechanisms for restricting exploitation of such vulnerabilities. In addition, the article discusses features and work methods of different RAM.

  18. Computer-aided diagnosis of mammographic microcalcification clusters

    International Nuclear Information System (INIS)

    Kallergi, Maria

    2004-01-01

    Computer-aided diagnosis techniques in medical imaging are developed for the automated differentiation between benign and malignant lesions and go beyond computer-aided detection by providing cancer likelihood for a detected lesion given image and/or patient characteristics. The goal of this study was the development and evaluation of a computer-aided detection and diagnosis algorithm for mammographic calcification clusters. The emphasis was on the diagnostic component, although the algorithm included automated detection, segmentation, and classification steps based on wavelet filters and artificial neural networks. Classification features were selected primarily from descriptors of the morphology of the individual calcifications and the distribution of the cluster. Thirteen such descriptors were selected and, combined with patient's age, were given as inputs to the network. The features were ranked and evaluated for the classification of 100 high-resolution, digitized mammograms containing biopsy-proven, benign and malignant calcification clusters. The classification performance of the algorithm reached a 100% sensitivity for a specificity of 85% (receiver operating characteristic area index A z =0.98±0.01). Tests of the algorithm under various conditions showed that the selected features were robust morphological and distributional descriptors, relatively insensitive to segmentation and detection errors such as false positive signals. The algorithm could exceed the performance of a similar visual analysis system that was used as basis for development and, combined with a simple image standardization process, could be applied to images from different imaging systems and film digitizers with similar sensitivity and specificity rates

  19. Computer Aided Design System for Developing Musical Fountain Programs

    Institute of Scientific and Technical Information of China (English)

    刘丹; 张乃尧; 朱汉城

    2003-01-01

    A computer aided design system for developing musical fountain programs was developed with multiple functions such as intelligent design, 3-D animation, manual modification and synchronized motion to make the development process more efficient. The system first analyzed the music form and sentiment using many basic features of the music to select a basic fountain program. Then, this program is simulated with 3-D animation and modified manually to achieve the desired results. Finally, the program is transformed to a computer control program to control the musical fountain in time with the music. A prototype system for the musical fountain was also developed. It was tested with many styles of music and users were quite satisfied with its performance. By integrating various functions, the proposed computer aided design system for developing musical fountain programs greatly simplified the design of the musical fountain programs.

  20. Computer Aided Solvent Selection and Design Framework

    DEFF Research Database (Denmark)

    Mitrofanov, Igor; Conte, Elisa; Abildskov, Jens

    and computer-aided tools and methods for property prediction and computer-aided molecular design (CAMD) principles. This framework is applicable for solvent selection and design in product design as well as process design. The first module of the framework is dedicated to the solvent selection and design...... in terms of: physical and chemical properties (solvent-pure properties); Environment, Health and Safety (EHS) characteristic (solvent-EHS properties); operational properties (solvent–solute properties). 3. Performing the search. The search step consists of two stages. The first is a generation and property...... identification of solvent candidates using special software ProCAMD and ProPred, which are the implementations of computer-aided molecular techniques. The second consists of assigning the RS-indices following the reaction–solvent and then consulting the known solvent database and identifying the set of solvents...

  1. Computer Aided Drug Design: Success and Limitations.

    Science.gov (United States)

    Baig, Mohammad Hassan; Ahmad, Khurshid; Roy, Sudeep; Ashraf, Jalaluddin Mohammad; Adil, Mohd; Siddiqui, Mohammad Haris; Khan, Saif; Kamal, Mohammad Amjad; Provazník, Ivo; Choi, Inho

    2016-01-01

    Over the last few decades, computer-aided drug design has emerged as a powerful technique playing a crucial role in the development of new drug molecules. Structure-based drug design and ligand-based drug design are two methods commonly used in computer-aided drug design. In this article, we discuss the theory behind both methods, as well as their successful applications and limitations. To accomplish this, we reviewed structure based and ligand based virtual screening processes. Molecular dynamics simulation, which has become one of the most influential tool for prediction of the conformation of small molecules and changes in their conformation within the biological target, has also been taken into account. Finally, we discuss the principles and concepts of molecular docking, pharmacophores and other methods used in computer-aided drug design.

  2. [Computer-aided Prognosis for Breast Cancer Based on Hematoxylin & Eosin Histopathology Image].

    Science.gov (United States)

    Chen, Jiamei; Qu, Aiping; Liu, Wenlou; Wang, Linwei; Yuan, Jingping; Liu, Juan; Li, Yan

    2016-06-01

    Quantitatively analyzing hematoxylin &eosin(H&E)histopathology images is an emerging field attracting increasing attentions in recent years.This paper reviews the application of computer-aided image analysis in breast cancer prognosis.The traditional prognosis based on H&E histopathology image for breast cancer is firstly sketched,followed by a detailed description of the workflow of computer-aided prognosis including image acquisition,image preprocessing,regions of interest detection and object segmentation,feature extraction,and computer-aided prognosis.In the end,major technical challenges and future directions in this field are summarized.

  3. A supervisor system for computer aided laser machining

    International Nuclear Information System (INIS)

    Mukherjee, J.K.

    1990-01-01

    Lasers achieve non divergent beam of short wavelength energy which can propagate through normal atmosphere with little divergence and can be focused on very fine points. The final high energy per unit area on target is highly localised and suitable for various types of machining at high speeds. The most notable factor is that this high energy spot can be located precisely using light-weight optical components. The laser-machining is very amenable to environmental conditions unlike electron beam and other techniques. Precision cutting and welding of nuclear materials in normal or non oxidising atmosphere can be done using this fairly easily. To achieve these objectives, development of a computer controlled laser machining system has been undertaken. The development project aims at building a computer aided machine with indegenous controller and medium power laser suitable for cutting, welding, and marking. This paper describes the integration of the various computer aided functions, spanning over the full range, from job-defining to final finished part-delivary, in computer aided laser machining. Various innovative features of the system that render it suitable for laser tool development as well as for special machining applications with user-friendliness have been covered. (author). 5 refs., 5 figs

  4. Computer Aided Continuous Time Stochastic Process Modelling

    DEFF Research Database (Denmark)

    Kristensen, N.R.; Madsen, Henrik; Jørgensen, Sten Bay

    2001-01-01

    A grey-box approach to process modelling that combines deterministic and stochastic modelling is advocated for identification of models for model-based control of batch and semi-batch processes. A computer-aided tool designed for supporting decision-making within the corresponding modelling cycle...

  5. Computer aided architectural design : futures 2001

    NARCIS (Netherlands)

    Vries, de B.; Leeuwen, van J.P.; Achten, H.H.

    2001-01-01

    CAAD Futures is a bi-annual conference that aims to promote the advancement of computer-aided architectural design in the service of those concerned with the quality of the built environment. The conferences are organized under the auspices of the CAAD Futures Foundation, which has its secretariat

  6. Computer-Aided Modelling Methods and Tools

    DEFF Research Database (Denmark)

    Cameron, Ian; Gani, Rafiqul

    2011-01-01

    The development of models for a range of applications requires methods and tools. In many cases a reference model is required that allows the generation of application specific models that are fit for purpose. There are a range of computer aided modelling tools available that help to define the m...

  7. Computer-Aided Corrosion Program Management

    Science.gov (United States)

    MacDowell, Louis

    2010-01-01

    This viewgraph presentation reviews Computer-Aided Corrosion Program Management at John F. Kennedy Space Center. The contents include: 1) Corrosion at the Kennedy Space Center (KSC); 2) Requirements and Objectives; 3) Program Description, Background and History; 4) Approach and Implementation; 5) Challenges; 6) Lessons Learned; 7) Successes and Benefits; and 8) Summary and Conclusions.

  8. New Paradigms for Computer Aids to Invention.

    Science.gov (United States)

    Langston, M. Diane

    Many people are interested in computer aids to rhetorical invention and want to know how to evaluate an invention aid, what the criteria are for a good one, and how to assess the trade-offs involved in buying one product or another. The frame of reference for this evaluation is an "old paradigm," which treats the computer as if it were…

  9. Computer-Aided Design in Further Education.

    Science.gov (United States)

    Ingham, Peter, Ed.

    This publication updates the 1982 occasional paper that was intended to foster staff awareness and assist colleges in Great Britain considering the use of computer-aided design (CAD) material in engineering courses. The paper begins by defining CAD and its place in the Integrated Business System with a brief discussion of the effect of CAD on the…

  10. Computer-aided dispatching system design specification

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, M.G.

    1997-12-16

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol Operations Center. This document reflects the as-built requirements for the system that was delivered by GTE Northwest, Inc. This system provided a commercial off-the-shelf computer-aided dispatching system and alarm monitoring system currently in operations at the Hanford Patrol Operations Center, Building 2721E. This system also provides alarm back-up capability for the Plutonium Finishing Plant (PFP).

  11. Computer-aided dispatching system design specification

    International Nuclear Information System (INIS)

    Briggs, M.G.

    1997-01-01

    This document defines the performance requirements for a graphic display dispatching system to support Hanford Patrol Operations Center. This document reflects the as-built requirements for the system that was delivered by GTE Northwest, Inc. This system provided a commercial off-the-shelf computer-aided dispatching system and alarm monitoring system currently in operations at the Hanford Patrol Operations Center, Building 2721E. This system also provides alarm back-up capability for the Plutonium Finishing Plant (PFP)

  12. Collaborative research on fluidization employing computer-aided particle tracking

    International Nuclear Information System (INIS)

    Chen, M.M.

    1990-01-01

    The objective of this work is to obtain unique, fundamental information on fluidization dynamics over a wide range of flow regimes using a Transportable Computer-Aided Particle Tracking Apparatus (TCAPTA). The contractor will design and fabricate a transportable version of the Computer-Aided Particle Tracking Facility (CAPTF) he has previously developed. The contractor will install and operate the (TCAPTA) at the METC fluidization research facilities. Quantitative data on particle motion will be obtained and reduced. The data will be used to provide needed information for modeling of bed dynamics, and prediction of bed performance, including erosion. A radioactive tracer particle, identical in size shape and mass to the bed particles under study, is mixed in the bed. The radiation emitted by the tracer particle, monitored continuously by 16 scintillation detectors, allows its position to be determined as a function of time. Stochastic mixing processes intrinsic to fluidization further cause the particle to travel to all active regions of the bed, thus sampling the motion in these regions. After a long test run to insure that a sufficient sampling have been acquired, time-differentiation and other statistical processing will then yield the mean velocity distribution, the fluctuating velocity distribution, many types of auto- and cross correlations, as well as mean fluxes, including the mean momentum fluxes due to random motion, which represent the kinetic contributions to the mean stress tensor

  13. Speech-enabled Computer-aided Translation

    DEFF Research Database (Denmark)

    Mesa-Lao, Bartolomé

    2014-01-01

    The present study has surveyed post-editor trainees’ views and attitudes before and after the introduction of speech technology as a front end to a computer-aided translation workbench. The aim of the survey was (i) to identify attitudes and perceptions among post-editor trainees before performing...... a post-editing task using automatic speech recognition (ASR); and (ii) to assess the degree to which post-editors’ attitudes and expectations to the use of speech technology changed after actually using it. The survey was based on two questionnaires: the first one administered before the participants...

  14. Computer-aided power systems analysis

    CERN Document Server

    Kusic, George

    2008-01-01

    Computer applications yield more insight into system behavior than is possible by using hand calculations on system elements. Computer-Aided Power Systems Analysis: Second Edition is a state-of-the-art presentation of basic principles and software for power systems in steady-state operation. Originally published in 1985, this revised edition explores power systems from the point of view of the central control facility. It covers the elements of transmission networks, bus reference frame, network fault and contingency calculations, power flow on transmission networks, generator base power setti

  15. [Clinical skills and outcomes of chair-side computer aided design and computer aided manufacture system].

    Science.gov (United States)

    Yu, Q

    2018-04-09

    Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.

  16. Integrated computer-aided design using minicomputers

    Science.gov (United States)

    Storaasli, O. O.

    1980-01-01

    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.

  17. Computer aided system engineering for space construction

    Science.gov (United States)

    Racheli, Ugo

    1989-01-01

    This viewgraph presentation covers the following topics. Construction activities envisioned for the assembly of large platforms in space (as well as interplanetary spacecraft and bases on extraterrestrial surfaces) require computational tools that exceed the capability of conventional construction management programs. The Center for Space Construction is investigating the requirements for new computational tools and, at the same time, suggesting the expansion of graduate and undergraduate curricula to include proficiency in Computer Aided Engineering (CAE) though design courses and individual or team projects in advanced space systems design. In the center's research, special emphasis is placed on problems of constructability and of the interruptability of planned activity sequences to be carried out by crews operating under hostile environmental conditions. The departure point for the planned work is the acquisition of the MCAE I-DEAS software, developed by the Structural Dynamics Research Corporation (SDRC), and its expansion to the level of capability denoted by the acronym IDEAS**2 currently used for configuration maintenance on Space Station Freedom. In addition to improving proficiency in the use of I-DEAS and IDEAS**2, it is contemplated that new software modules will be developed to expand the architecture of IDEAS**2. Such modules will deal with those analyses that require the integration of a space platform's configuration with a breakdown of planned construction activities and with a failure modes analysis to support computer aided system engineering (CASE) applied to space construction.

  18. Computer-Aided Drug Design in Epigenetics

    Directory of Open Access Journals (Sweden)

    Wenchao Lu

    2018-03-01

    Full Text Available Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation, and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field.

  19. Computer-Aided Drug Design in Epigenetics

    Science.gov (United States)

    Lu, Wenchao; Zhang, Rukang; Jiang, Hao; Zhang, Huimin; Luo, Cheng

    2018-01-01

    Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation, and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field. PMID:29594101

  20. Computer-Aided Drug Design in Epigenetics

    Science.gov (United States)

    Lu, Wenchao; Zhang, Rukang; Jiang, Hao; Zhang, Huimin; Luo, Cheng

    2018-03-01

    Epigenetic dysfunction has been widely implicated in several diseases especially cancers thus highlights the therapeutic potential for chemical interventions in this field. With rapid development of computational methodologies and high-performance computational resources, computer-aided drug design has emerged as a promising strategy to speed up epigenetic drug discovery. Herein, we make a brief overview of major computational methods reported in the literature including druggability prediction, virtual screening, homology modeling, scaffold hopping, pharmacophore modeling, molecular dynamics simulations, quantum chemistry calculation and 3D quantitative structure activity relationship that have been successfully applied in the design and discovery of epi-drugs and epi-probes. Finally, we discuss about major limitations of current virtual drug design strategies in epigenetics drug discovery and future directions in this field.

  1. Computer-Aided Design of Antimicrobial Peptides

    DEFF Research Database (Denmark)

    Fjell, Christopher D.; Hancock, Robert E.W.; Jenssen, Håvard

    2010-01-01

    in antimicrobial activity. Consequently, the majority of peptides put into clinical trials have failed at some point, underlining the importance of a thorough peptide optimization. An important tool in peptide design and optimization is quantitative structure-activity relationship (QSAR) analysis, correlating...... chemical parameters with biological activities of the peptide, using statistical methods. In this review we will discuss two different in silico strategies of computer-aided antibacterial peptide design, a linear correlation model build as an extension of traditional principal component analysis (PCA......) and a non-linear artificial neural network model. Studies on structurally diverse peptides, have concluded that the PCA derived model are able to guide the antibacterial peptide design in a meaningful way, however requiring rather a high homology between the peptides in the test-set and the in silico...

  2. Computer-aided diagnosis in routine mammography

    International Nuclear Information System (INIS)

    Sittek, H.; Perlet, C.; Helmberger, R.; Linsmeier, E.; Kessler, M.; Reiser, M.

    1998-01-01

    Purpose: Computer-aided diagnosis in mammography is a topic many study groups have been concerned with since the first presentation of a system for computer-aided interpretation in 1967. Currently, there is only one system avilable for clinical use in mammography, the CAD-System Image Checker (R2 Technology). The purpose of our prospective study was to evaluate whether the integration of the CAD-system into the routine of a radiological breast diagnosis unit is feasible. Results: After the installation of the CAD-system, 300 patients with 1110 mammograms were included for evaluation in the present study. In 54 of these cases histological examination was indicated due to suspect criteria on conventional mammography. In 39 of 54 cases (72,2%) malignancy could be proven histologically. The CAD-system marked 82,1% of the histologically verified carcinomas correctly 94,3% of all 1797 marks made by the CAD-system indicated normal or benign structures. Routinely performed CAD analysis prolonged patients waiting time by about 15 min because the marks of the CAD system had to be interpreted in addition to the routine diagnostic investigations. Conclusion: Our experience with the use of the CAD-system in daily routine showed that CAD analysis can easily be integrated into a preexisting mammography unit. However, the diagnostic benefit is not yet clearly established. Since the rate of false negative marks by the CAD-system Image Checker is still high, the results of CAD analysis must be checked and corrected by an observer well experienced in mammography reading. (orig.) [de

  3. Computer-aided diagnosis of liver tumors on computed tomography images.

    Science.gov (United States)

    Chang, Chin-Chen; Chen, Hong-Hao; Chang, Yeun-Chung; Yang, Ming-Yang; Lo, Chung-Ming; Ko, Wei-Chun; Lee, Yee-Fan; Liu, Kao-Lang; Chang, Ruey-Feng

    2017-07-01

    Liver cancer is the tenth most common cancer in the USA, and its incidence has been increasing for several decades. Early detection, diagnosis, and treatment of the disease are very important. Computed tomography (CT) is one of the most common and robust imaging techniques for the detection of liver cancer. CT scanners can provide multiple-phase sequential scans of the whole liver. In this study, we proposed a computer-aided diagnosis (CAD) system to diagnose liver cancer using the features of tumors obtained from multiphase CT images. A total of 71 histologically-proven liver tumors including 49 benign and 22 malignant lesions were evaluated with the proposed CAD system to evaluate its performance. Tumors were identified by the user and then segmented using a region growing algorithm. After tumor segmentation, three kinds of features were obtained for each tumor, including texture, shape, and kinetic curve. The texture was quantified using 3 dimensional (3-D) texture data of the tumor based on the grey level co-occurrence matrix (GLCM). Compactness, margin, and an elliptic model were used to describe the 3-D shape of the tumor. The kinetic curve was established from each phase of tumor and represented as variations in density between each phase. Backward elimination was used to select the best combination of features, and binary logistic regression analysis was used to classify the tumors with leave-one-out cross validation. The accuracy and sensitivity for the texture were 71.82% and 68.18%, respectively, which were better than for the shape and kinetic curve under closed specificity. Combining all of the features achieved the highest accuracy (58/71, 81.69%), sensitivity (18/22, 81.82%), and specificity (40/49, 81.63%). The Az value of combining all features was 0.8713. Combining texture, shape, and kinetic curve features may be able to differentiate benign from malignant tumors in the liver using our proposed CAD system. Copyright © 2017 Elsevier B.V. All

  4. Intelligent Support for a Computer Aided Design Optimisation Cycle

    OpenAIRE

    B. Dolšak; M. Novak; J. Kaljun

    2006-01-01

    It is becoming more and more evident that  adding intelligence  to existing computer aids, such as computer aided design systems, can lead to significant improvements in the effective and reliable performance of various engineering tasks, including design optimisation. This paper presents three different intelligent modules to be applied within a computer aided design optimisation cycle to enable more intelligent and less experience-dependent design performance. 

  5. Computer-Aided Manufacturing of 3D Workpieces

    OpenAIRE

    Cornelia Victoria Anghel Drugarin; Mihaela Dorica Stroia

    2017-01-01

    Computer-Aided Manufacturing (CAM) assumes to use dedicated software for controlling machine tools and similar devices in the process of workpieces manufacturing. CAM is, in fact, an application technology that uses computer software and machinery to simplify and automate manufacturing processes. CAM is the inheritor of computer-aided engineering (CAE) and is often used conjunctively with computer-aided design (CAD). Advanced CAM solutions are forthcoming and have a large ...

  6. Computer Aided Methodology for Simultaneous Synthesis, Design & Analysis of Chemical Products-Processes

    DEFF Research Database (Denmark)

    d'Anterroches, Loïc; Gani, Rafiqul

    2006-01-01

    A new combined methodology for computer aided molecular design and process flowsheet design is presented. The methodology is based on the group contribution approach for prediction of molecular properties and design of molecules. Using the same principles, process groups have been developed...... a wide range of problems. In this paper, only the computer aided flowsheet design related features are presented....... together with their corresponding flowsheet property models. To represent the process flowsheets in the same way as molecules, a unique but simple notation system has been developed. The methodology has been converted into a prototype software, which has been tested with several case studies covering...

  7. Computer aided systems human engineering: A hypermedia tool

    Science.gov (United States)

    Boff, Kenneth R.; Monk, Donald L.; Cody, William J.

    1992-01-01

    The Computer Aided Systems Human Engineering (CASHE) system, Version 1.0, is a multimedia ergonomics database on CD-ROM for the Apple Macintosh II computer, being developed for use by human system designers, educators, and researchers. It will initially be available on CD-ROM and will allow users to access ergonomics data and models stored electronically as text, graphics, and audio. The CASHE CD-ROM, Version 1.0 will contain the Boff and Lincoln (1988) Engineering Data Compendium, MIL-STD-1472D and a unique, interactive simulation capability, the Perception and Performance Prototyper. Its features also include a specialized data retrieval, scaling, and analysis capability and the state of the art in information retrieval, browsing, and navigation.

  8. A computer-aided software-tool for sustainable process synthesis-intensification

    DEFF Research Database (Denmark)

    Kumar Tula, Anjan; Babi, Deenesh K.; Bottlaender, Jack

    2017-01-01

    and determine within the design space, the more sustainable processes. In this paper, an integrated computer-aided software-tool that searches the design space for hybrid/intensified more sustainable process options is presented. Embedded within the software architecture are process synthesis...... operations as well as reported hybrid/intensified unit operations is large and can be difficult to manually navigate in order to determine the best process flowsheet for the production of a desired chemical product. Therefore, it is beneficial to utilize computer-aided methods and tools to enumerate, analyze...... constraints while also matching the design targets, they are therefore more sustainable than the base case. The application of the software-tool to the production of biodiesel is presented, highlighting the main features of the computer-aided, multi-stage, multi-scale methods that are able to determine more...

  9. Automatic computer aided analysis algorithms and system for adrenal tumors on CT images.

    Science.gov (United States)

    Chai, Hanchao; Guo, Yi; Wang, Yuanyuan; Zhou, Guohui

    2017-12-04

    The adrenal tumor will disturb the secreting function of adrenocortical cells, leading to many diseases. Different kinds of adrenal tumors require different therapeutic schedules. In the practical diagnosis, it highly relies on the doctor's experience to judge the tumor type by reading the hundreds of CT images. This paper proposed an automatic computer aided analysis method for adrenal tumors detection and classification. It consisted of the automatic segmentation algorithms, the feature extraction and the classification algorithms. These algorithms were then integrated into a system and conducted on the graphic interface by using MATLAB Graphic user interface (GUI). The accuracy of the automatic computer aided segmentation and classification reached 90% on 436 CT images. The experiments proved the stability and reliability of this automatic computer aided analytic system.

  10. An esthetics rehabilitation with computer-aided design/ computer-aided manufacturing technology.

    Science.gov (United States)

    Mazaro, Josá Vitor Quinelli; de Mello, Caroline Cantieri; Zavanelli, Adriana Cristina; Santiago, Joel Ferreira; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza

    2014-07-01

    This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.

  11. Computer Aided Design of Kaplan Turbine Piston with\tSolidWorks

    Directory of Open Access Journals (Sweden)

    Camelia Jianu

    2010-10-01

    Full Text Available The paper presents the steps for 3D computer aided design (CAD of Kaplan turbine piston made in SolidWorks.The present paper is a tutorial for a Kaplan turbine piston 3D geometry, which is dedicaded to the Parts Sketch and Parts Features design and Drawing Geometry and Drawing Annotation.

  12. Computer Aided Design of Kaplan Turbine Piston with SolidWorks

    OpenAIRE

    Camelia Jianu

    2010-01-01

    The paper presents the steps for 3D computer aided design (CAD) of Kaplan turbine piston made in SolidWorks.The present paper is a tutorial for a Kaplan turbine piston 3D geometry, which is dedicaded to the Parts Sketch and Parts Features design and Drawing Geometry and Drawing Annotation.

  13. Computer-aided sperm analysis: a useful tool to evaluate patient's response to varicocelectomy

    OpenAIRE

    Ariagno, Julia I; Mendeluk, Gabriela R; Furlan, Mar?a J; Sardi, M; Chenlo, P; Curi, Susana M; Pugliese, Mercedes N; Repetto, Herberto E; Cohen, Mariano

    2016-01-01

    Preoperative and postoperative sperm parameter values from infertile men with varicocele were analyzed by computer-aided sperm analysis (CASA) to assess if sperm characteristics improved after varicocelectomy. Semen samples of men with proven fertility (n = 38) and men with varicocele-related infertility (n = 61) were also analyzed. Conventional semen analysis was performed according to WHO (2010) criteria and a CASA system was employed to assess kinetic parameters and sperm concentration. Se...

  14. Computer-Aided Parallelizer and Optimizer

    Science.gov (United States)

    Jin, Haoqiang

    2011-01-01

    The Computer-Aided Parallelizer and Optimizer (CAPO) automates the insertion of compiler directives (see figure) to facilitate parallel processing on Shared Memory Parallel (SMP) machines. While CAPO currently is integrated seamlessly into CAPTools (developed at the University of Greenwich, now marketed as ParaWise), CAPO was independently developed at Ames Research Center as one of the components for the Legacy Code Modernization (LCM) project. The current version takes serial FORTRAN programs, performs interprocedural data dependence analysis, and generates OpenMP directives. Due to the widely supported OpenMP standard, the generated OpenMP codes have the potential to run on a wide range of SMP machines. CAPO relies on accurate interprocedural data dependence information currently provided by CAPTools. Compiler directives are generated through identification of parallel loops in the outermost level, construction of parallel regions around parallel loops and optimization of parallel regions, and insertion of directives with automatic identification of private, reduction, induction, and shared variables. Attempts also have been made to identify potential pipeline parallelism (implemented with point-to-point synchronization). Although directives are generated automatically, user interaction with the tool is still important for producing good parallel codes. A comprehensive graphical user interface is included for users to interact with the parallelization process.

  15. A computer-aided continuous assessment system

    Directory of Open Access Journals (Sweden)

    B. C.H. Turton

    1996-12-01

    Full Text Available Universities within the United Kingdom have had to cope with a massive expansion in undergraduate student numbers over the last five years (Committee of Scottish University Principals, 1993; CVCP Briefing Note, 1994. In addition, there has been a move towards modularization and a closer monitoring of a student's progress throughout the year. Since the price/performance ratio of computer systems has continued to improve, Computer- Assisted Learning (CAL has become an attractive option. (Fry, 1990; Benford et al, 1994; Laurillard et al, 1994. To this end, the Universities Funding Council (UFQ has funded the Teaching and Learning Technology Programme (TLTP. However universities also have a duty to assess as well as to teach. This paper describes a Computer-Aided Assessment (CAA system capable of assisting in grading students and providing feedback. In this particular case, a continuously assessed course (Low-Level Languages of over 100 students is considered. Typically, three man-days are required to mark one assessed piece of coursework from the students in this class. Any feedback on how the questions were dealt with by the student are of necessity brief. Most of the feedback is provided in a tutorial session that covers the pitfalls encountered by the majority of the students.

  16. Computer aided materials design; Keisanki zairyo sekkei

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The questionnaire survey on the computer aided materials design (CAMD), and the survey of current domestic and overseas software concerned were carried out to clarify developmental issues. The current elementary technology of CAMD was also surveyed to study its several problems caused with a progress of material design technology due to drastic diffusion of CAMD. This project aims at establishment of a new demanded software, computer chemistry, focusing attention on functional materials such as catalyst, polymer and non-linear electronic materials. Microscopic simulation technology was mainly surveyed in fiscal 1996. Although some fruitful results have been obtained in the fields of medical and agricultural chemicals, organic compounds, proteins, catalysts and electronic materials, such some problems are pointed out as `CAMD cannot handle an actual size of the target system` and `commercially available software are very expensive.` Reliable tool development as elementary technology, and the verification of its applications are thus required. Meso-dynamics, polymers, surface reaction and integrated technological environment attract users` attention. 27 refs., 16 figs., 2 tabs.

  17. Computer-aided design for metabolic engineering.

    Science.gov (United States)

    Fernández-Castané, Alfred; Fehér, Tamás; Carbonell, Pablo; Pauthenier, Cyrille; Faulon, Jean-Loup

    2014-12-20

    The development and application of biotechnology-based strategies has had a great socio-economical impact and is likely to play a crucial role in the foundation of more sustainable and efficient industrial processes. Within biotechnology, metabolic engineering aims at the directed improvement of cellular properties, often with the goal of synthesizing a target chemical compound. The use of computer-aided design (CAD) tools, along with the continuously emerging advanced genetic engineering techniques have allowed metabolic engineering to broaden and streamline the process of heterologous compound-production. In this work, we review the CAD tools available for metabolic engineering with an emphasis, on retrosynthesis methodologies. Recent advances in genetic engineering strategies for pathway implementation and optimization are also reviewed as well as a range of bionalytical tools to validate in silico predictions. A case study applying retrosynthesis is presented as an experimental verification of the output from Retropath, the first complete automated computational pipeline applicable to metabolic engineering. Applying this CAD pipeline, together with genetic reassembly and optimization of culture conditions led to improved production of the plant flavonoid pinocembrin. Coupling CAD tools with advanced genetic engineering strategies and bioprocess optimization is crucial for enhanced product yields and will be of great value for the development of non-natural products through sustainable biotechnological processes. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Computer aided diagnosis of diabetic peripheral neuropathy

    Science.gov (United States)

    Chekh, Viktor; Soliz, Peter; McGrew, Elizabeth; Barriga, Simon; Burge, Mark; Luan, Shuang

    2014-03-01

    Diabetic peripheral neuropathy (DPN) refers to the nerve damage that can occur in diabetes patients. It most often affects the extremities, such as the feet, and can lead to peripheral vascular disease, deformity, infection, ulceration, and even amputation. The key to managing diabetic foot is prevention and early detection. Unfortunately, current existing diagnostic techniques are mostly based on patient sensations and exhibit significant inter- and intra-observer differences. We have developed a computer aided diagnostic (CAD) system for diabetic peripheral neuropathy. The thermal response of the feet of diabetic patients following cold stimulus is captured using an infrared camera. The plantar foot in the images from a thermal video are segmented and registered for tracking points or specific regions. The temperature recovery of each point on the plantar foot is extracted using our bio-thermal model and analyzed. The regions that exhibit abnormal ability to recover are automatically identified to aid the physicians to recognize problematic areas. The key to our CAD system is the segmentation of infrared video. The main challenges for segmenting infrared video compared to normal digital video are (1) as the foot warms up, it also warms up the surrounding, creating an ever changing contrast; and (2) there may be significant motion during imaging. To overcome this, a hybrid segmentation algorithm was developed based on a number of techniques such as continuous max-flow, model based segmentation, shape preservation, convex hull, and temperature normalization. Verifications of the automatic segmentation and registration using manual segmentation and markers show good agreement.

  19. Computer aided probabilistic assessment of containment integrity

    International Nuclear Information System (INIS)

    Tsai, J.C.; Touchton, R.A.

    1984-01-01

    In the probabilistic risk assessment (PRA) of a nuclear power plant, there are three probability-based techniques which are widely used for event sequence frequency quantification (including nodal probability estimation). These three techniques are the event tree analysis, the fault tree analysis and the Bayesian approach for database development. In the barrier analysis for assessing radionuclide release to the environment in a PRA study, these techniques are employed to a greater extent in estimating conditions which could lead to failure of the fuel cladding and the reactor coolant system (RCS) pressure boundary, but to a lesser degree in the containment pressure boundary failure analysis. The main reason is that containment issues are currently still in a state of flux. In this paper, the authors describe briefly the computer programs currently used by the nuclear industry to do event tree analyses, fault tree analyses and the Bayesian update. The authors discuss how these computer aided probabilistic techniques might be adopted for failure analysis of the containment pressure boundary

  20. Geometric modeling for computer aided design

    Science.gov (United States)

    Schwing, James L.; Olariu, Stephen

    1995-01-01

    The primary goal of this grant has been the design and implementation of software to be used in the conceptual design of aerospace vehicles particularly focused on the elements of geometric design, graphical user interfaces, and the interaction of the multitude of software typically used in this engineering environment. This has resulted in the development of several analysis packages and design studies. These include two major software systems currently used in the conceptual level design of aerospace vehicles. These tools are SMART, the Solid Modeling Aerospace Research Tool, and EASIE, the Environment for Software Integration and Execution. Additional software tools were designed and implemented to address the needs of the engineer working in the conceptual design environment. SMART provides conceptual designers with a rapid prototyping capability and several engineering analysis capabilities. In addition, SMART has a carefully engineered user interface that makes it easy to learn and use. Finally, a number of specialty characteristics have been built into SMART which allow it to be used efficiently as a front end geometry processor for other analysis packages. EASIE provides a set of interactive utilities that simplify the task of building and executing computer aided design systems consisting of diverse, stand-alone, analysis codes. Resulting in a streamlining of the exchange of data between programs reducing errors and improving the efficiency. EASIE provides both a methodology and a collection of software tools to ease the task of coordinating engineering design and analysis codes.

  1. Computer-Aided Video Differential Planimetry

    Science.gov (United States)

    Tobin, Michael; Djoleto, Ben D.

    1984-08-01

    THE VIDEO DIFFERENTIAL PLANIMETER (VDP)1 is a re-mote sensing instrument that can measure minute changes in the area of any object seen by an optical scanning system. The composite video waveforms obtained by scanning the object against a contrasting back-ground are amplified and shaped to yield a sequence of constant amplitude pulses whose polarity distinguishes the studied area from its background and whose varying widths reflect the dynamics of the viewed object. These pulses are passed through a relatively long time-constant capacitor-resistor circuit and are then fed into an integrator. The net integration voltage resulting from the most recent sequence of object-background time pulses is recorded and the integrator is returned to zero at the end of each video frame. If the object's area remains constant throughout the following frame, the integrator's summation will also remain constant. However, if the object's area varies, the positive and negative time pulses entering the integrator will change, and the integrator's summation will vary proportionately. The addition of a computer interface and a video recorder enhances the versatility and the resolving power of the VDP by permitting the repeated study and analysis of selected portions of the recorded data, thereby uncovering the major sources of the object's dynamics. Among the medical and biological procedures for which COMPUTER-AIDED VIDEO DIFFERENTIAL PLANIMETRY is suitable are Ophthalmoscopy, Endoscopy, Microscopy, Plethysmography, etc. A recent research study in Ophthalmoscopy2 will be cited to suggest a useful application of Video Differential Planimetry.

  2. Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns

    NARCIS (Netherlands)

    Lohbauer, Ulrich; Belli, Renan; Cune, Marco S; Schepke, Ulf

    2017-01-01

    Today, a substantial part of the dental crown production uses computer-aided design and computer-aided manufacturing (CAD/CAM) technology. A recent step in restorative dentistry is the replacement of natural tooth structure with pre-polymerized and machined resin-based methacrylic polymers.

  3. COMPUTER-AIDED DETECTION OF ACINAR SHADOWS IN CHEST RADIOGRAPHS

    Directory of Open Access Journals (Sweden)

    Tao Xu

    2013-05-01

    Full Text Available Despite the technological advances in medical diagnosis, accurate detection of infectious tuberculosis (TB still poses challenges due to complex image features and thus infectious TB continues to be a public health problem of global proportions. Currently, the detection of TB is mainly conducted visually by radiologists examining chest radiographs (CXRs. To reduce the backlog of CXR examination and provide more precise quantitative assessment, computer-aided detection (CAD systems for potential lung lesions have been increasingly adopted and commercialized for clinical practice. CADs work as supporting tools to alert radiologists on suspected features that could have easily been neglected. In this paper, an effective CAD system aimed for acinar shadow regions detection in CXRs is proposed. This system exploits textural and photometric features analysis techniques which include local binary pattern (LBP, grey level co-occurrence matrix (GLCM and histogram of oriented gradients (HOG to analyze target regions in CXRs. Classification of acinar shadows using Adaboost is then deployed to verify the performance of a combination of these techniques. Comparative study in different image databases shows that the proposed CAD system delivers consistent high accuracy in detecting acinar shadows.

  4. Computer Aided Diagnosis System for Early Lung Cancer Detection

    Directory of Open Access Journals (Sweden)

    Fatma Taher

    2015-11-01

    Full Text Available Lung cancer continues to rank as the leading cause of cancer deaths worldwide. One of the most promising techniques for early detection of cancerous cells relies on sputum cell analysis. This was the motivation behind the design and the development of a new computer aided diagnosis (CAD system for early detection of lung cancer based on the analysis of sputum color images. The proposed CAD system encompasses four main processing steps. First is the preprocessing step which utilizes a Bayesian classification method using histogram analysis. Then, in the second step, mean shift segmentation is applied to segment the nuclei from the cytoplasm. The third step is the feature analysis. In this step, geometric and chromatic features are extracted from the nucleus region. These features are used in the diagnostic process of the sputum images. Finally, the diagnosis is completed using an artificial neural network and support vector machine (SVM for classifying the cells into benign or malignant. The performance of the system was analyzed based on different criteria such as sensitivity, specificity and accuracy. The evaluation was carried out using Receiver Operating Characteristic (ROC curve. The experimental results demonstrate the efficiency of the SVM classifier over other classifiers, with 97% sensitivity and accuracy as well as a significant reduction in the number of false positive and false negative rates.

  5. An integrated computer aided system for integrated design of chemical processes

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Hytoft, Glen; Jaksland, Cecilia

    1997-01-01

    In this paper, an Integrated Computer Aided System (ICAS), which is particularly suitable for solving problems related to integrated design of chemical processes; is presented. ICAS features include a model generator (generation of problem specific models including model simplification and model ...... form the basis for the toolboxes. The available features of ICAS are highlighted through a case study involving the separation of binary azeotropic mixtures. (C) 1997 Elsevier Science Ltd....

  6. Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.

    Science.gov (United States)

    Pendola, Martin; Saha, Subrata

    2015-01-01

    Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.

  7. Adhesive Bonding to Computer-aided Design/ Computer-aided Manufacturing Esthetic Dental Materials: An Overview.

    Science.gov (United States)

    Awad, Mohamed Moustafa; Alqahtani, H; Al-Mudahi, A; Murayshed, M S; Alrahlah, A; Bhandi, Shilpa H

    2017-07-01

    To review the adhesive bonding to different computer-aided design/computer-aided manufacturing (CAD/CAM) esthetic restorative materials. The use of CAD/CAM esthetic restorative materials has gained popularity in recent years. Several CAD/ CAM esthetic restorative materials are commercially available. Adhesive bonding is a major determinant of success of CAD/ CAM restorations. Review result: An account of the currently available bonding strategies are discussed with their rationale in various CAD/ CAM materials. Different surface treatment methods as well as adhesion promoters can be used to achieve reliable bonding of CAD/CAM restorative materials. Selection of bonding strategy to such material is determined based on its composition. Further evidence is required to evaluate the effect of new surface treatment methods, such as nonthermal atmospheric plasma and self-etching ceramic primer on bonding to different dental ceramics. An understanding of the currently available bonding strategies to CA/CAM materials can help the clinician to select the most indicated system for each category of materials.

  8. Torsional strength of computer-aided design/computer-aided manufacturing-fabricated esthetic orthodontic brackets.

    Science.gov (United States)

    Alrejaye, Najla; Pober, Richard; Giordano Ii, Russell

    2017-01-01

    To fabricate orthodontic brackets from esthetic materials and determine their fracture resistance during archwire torsion. Computer-aided design/computer-aided manufacturing technology (Cerec inLab, Sirona) was used to mill brackets with a 0.018 × 0.025-inch slot. Materials used were Paradigm MZ100 and Lava Ultimate resin composite (3M ESPE), Mark II feldspathic porcelain (Vita Zahnfabrik), and In-Ceram YZ zirconia (Vita Zahnfabrik). Ten brackets of each material were subjected to torque by a 0.018 × 0.025-inch stainless steel archwire (G&H) using a specially designed apparatus. The average moments and degrees of torsion necessary to fracture the brackets were determined and compared with those of commercially available alumina brackets, Mystique MB (Dentsply GAC). The YZ brackets were statistically significantly stronger than any other tested material in their resistance to torsion (P brackets. Resistance of MZ100 and Lava Ultimate composite resin brackets to archwire torsion was comparable to commercially available alumina ceramic brackets.

  9. Multimedia Image Technology and Computer Aided Manufacturing Engineering Analysis

    Science.gov (United States)

    Nan, Song

    2018-03-01

    Since the reform and opening up, with the continuous development of science and technology in China, more and more advanced science and technology have emerged under the trend of diversification. Multimedia imaging technology, for example, has a significant and positive impact on computer aided manufacturing engineering in China. From the perspective of scientific and technological advancement and development, the multimedia image technology has a very positive influence on the application and development of computer-aided manufacturing engineering, whether in function or function play. Therefore, this paper mainly starts from the concept of multimedia image technology to analyze the application of multimedia image technology in computer aided manufacturing engineering.

  10. Computer Aided Design Tools for Extreme Environment Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project aims to provide Computer Aided Design (CAD) tools for radiation-tolerant, wide-temperature-range digital, analog, mixed-signal, and radio-frequency...

  11. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    National Research Council Canada - National Science Library

    Singh, Swatee; Lo, Joseph

    2008-01-01

    The purpose of this study was to investigate feasibility of computer-aided detection of masses and calcification clusters in breast tomosynthesis images and obtain reliable estimates of sensitivity...

  12. The potential impact of computer-aided assessment technology in ...

    African Journals Online (AJOL)

    The potential impact of computer-aided assessment technology in higher education. ... Further more 'Increased number of students in Higher Education and the ... benefits, limitations, impacts on student learning and strategies for developing ...

  13. Computer-Aided Qualitative Data Analysis with Word

    Directory of Open Access Journals (Sweden)

    Bruno Nideröst

    2002-05-01

    Full Text Available Despite some fragmentary references in the literature about qualitative methods, it is fairly unknown that Word can be successfully used for computer-aided Qualitative Data Analyses (QDA. Based on several Word standard operations, elementary QDA functions such as sorting data, code-and-retrieve and frequency counts can be realized. Word is particularly interesting for those users who wish to have first experiences with computer-aided analysis before investing time and money in a specialized QDA Program. The well-known standard software could also be an option for those qualitative researchers who usually work with word processing but have certain reservations towards computer-aided analysis. The following article deals with the most important requirements and options of Word for computer-aided QDA. URN: urn:nbn:de:0114-fqs0202225

  14. DICOM standard in computer-aided medical technologies

    International Nuclear Information System (INIS)

    Plotnikov, A.V.; Prilutskij, D.A.; Selishchev, S.V.

    1997-01-01

    The paper outlines one of the promising standards to transmit images in medicine, in radiology in particular. the essence of the standard DICOM is disclosed and promises of its introduction into computer-aided medical technologies

  15. Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT)

    Science.gov (United States)

    Consortium and Partners | Transportation Research | NREL Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Consortium and Partners Computer-Aided Engineering for Electric -Drive Vehicle Batteries (CAEBAT) Consortium and Partners The Computer-Aided Engineering for Electric

  16. Computer-aided engineering in High Energy Physics

    International Nuclear Information System (INIS)

    Bachy, G.; Hauviller, C.; Messerli, R.; Mottier, M.

    1988-01-01

    Computing, standard tool for a long time in the High Energy Physics community, is being slowly introduced at CERN in the mechanical engineering field. The first major application was structural analysis followed by Computer-Aided Design (CAD). Development work is now progressing towards Computer-Aided Engineering around a powerful data base. This paper gives examples of the power of this approach applied to engineering for accelerators and detectors

  17. Computer-aided system for cryogenic research facilities

    International Nuclear Information System (INIS)

    Gerasimov, V.P.; Zhelamsky, M.V.; Mozin, I.V.; Repin, S.S.

    1994-01-01

    A computer-aided system is developed for the more effective choice and optimization of the design and manufacturing technologies of the superconductor for the magnet system of the International Thermonuclear Experimental Reactor (ITER) with the aim to ensure the superconductor certification. The computer-aided system provides acquisition, processing, storage and display of data describing the proceeding tests, the detection of any parameter deviations and their analysis. Besides, it generates commands for the equipment switch off in emergency situations. ((orig.))

  18. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    Science.gov (United States)

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  19. [Computer-aided Diagnosis and New Electronic Stethoscope].

    Science.gov (United States)

    Huang, Mei; Liu, Hongying; Pi, Xitian; Ao, Yilu; Wang, Zi

    2017-05-30

    Auscultation is an important method in early-diagnosis of cardiovascular disease and respiratory system disease. This paper presents a computer-aided diagnosis of new electronic auscultation system. It has developed an electronic stethoscope based on condenser microphone and the relevant intelligent analysis software. It has implemented many functions that combined with Bluetooth, OLED, SD card storage technologies, such as real-time heart and lung sounds auscultation in three modes, recording and playback, auscultation volume control, wireless transmission. The intelligent analysis software based on PC computer utilizes C# programming language and adopts SQL Server as the background database. It has realized play and waveform display of the auscultation sound. By calculating the heart rate, extracting the characteristic parameters of T1, T2, T12, T11, it can analyze whether the heart sound is normal, and then generate diagnosis report. Finally the auscultation sound and diagnosis report can be sent to mailbox of other doctors, which can carry out remote diagnosis. The whole system has features of fully function, high portability, good user experience, and it is beneficial to promote the use of electronic stethoscope in the hospital, at the same time, the system can also be applied to auscultate teaching and other occasions.

  20. A handheld computer-aided diagnosis system and simulated analysis

    Science.gov (United States)

    Su, Mingjian; Zhang, Xuejun; Liu, Brent; Su, Kening; Louie, Ryan

    2016-03-01

    This paper describes a Computer Aided Diagnosis (CAD) system based on cellphone and distributed cluster. One of the bottlenecks in building a CAD system for clinical practice is the storage and process of mass pathology samples freely among different devices, and normal pattern matching algorithm on large scale image set is very time consuming. Distributed computation on cluster has demonstrated the ability to relieve this bottleneck. We develop a system enabling the user to compare the mass image to a dataset with feature table by sending datasets to Generic Data Handler Module in Hadoop, where the pattern recognition is undertaken for the detection of skin diseases. A single and combination retrieval algorithm to data pipeline base on Map Reduce framework is used in our system in order to make optimal choice between recognition accuracy and system cost. The profile of lesion area is drawn by doctors manually on the screen, and then uploads this pattern to the server. In our evaluation experiment, an accuracy of 75% diagnosis hit rate is obtained by testing 100 patients with skin illness. Our system has the potential help in building a novel medical image dataset by collecting large amounts of gold standard during medical diagnosis. Once the project is online, the participants are free to join and eventually an abundant sample dataset will soon be gathered enough for learning. These results demonstrate our technology is very promising and expected to be used in clinical practice.

  1. Computer-Aided Characterization and Diagnosis of Diffuse Liver Diseases Based on Ultrasound Imaging: A Review.

    Science.gov (United States)

    Bharti, Puja; Mittal, Deepti; Ananthasivan, Rupa

    2016-04-19

    Diffuse liver diseases, such as hepatitis, fatty liver, and cirrhosis, are becoming a leading cause of fatality and disability all over the world. Early detection and diagnosis of these diseases is extremely important to save lives and improve effectiveness of treatment. Ultrasound imaging, a noninvasive diagnostic technique, is the most commonly used modality for examining liver abnormalities. However, the accuracy of ultrasound-based diagnosis depends highly on expertise of radiologists. Computer-aided diagnosis systems based on ultrasound imaging assist in fast diagnosis, provide a reliable "second opinion" for experts, and act as an effective tool to measure response of treatment on patients undergoing clinical trials. In this review, we first describe appearance of liver abnormalities in ultrasound images and state the practical issues encountered in characterization of diffuse liver diseases that can be addressed by software algorithms. We then discuss computer-aided diagnosis in general with features and classifiers relevant to diffuse liver diseases. In later sections of this paper, we review the published studies and describe the key findings of those studies. A concise tabular summary comparing image database, features extraction, feature selection, and classification algorithms presented in the published studies is also exhibited. Finally, we conclude with a summary of key findings and directions for further improvements in the areas of accuracy and objectiveness of computer-aided diagnosis. © The Author(s) 2016.

  2. Improved mammographic interpretation of masses using computer-aided diagnosis

    International Nuclear Information System (INIS)

    Leichter, I.; Fields, S.; Novak, B.; Nirel, R.; Bamberger, P.; Lederman, R.; Buchbinder, S.

    2000-01-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p z ) increased significantly (p z for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that of the unassisted radiologist. Our findings suggest that objective quantitative features extracted from digitized mammographic findings may help in differentiating between benign and malignant masses, and can assist the radiologist in the interpretation of mass lesions. (orig.)

  3. Computer aided plant engineering: An analysis and suggestions for computer use

    International Nuclear Information System (INIS)

    Leinemann, K.

    1979-09-01

    To get indications to and boundary conditions for computer use in plant engineering, an analysis of the engineering process was done. The structure of plant engineering is represented by a network of substaks and subsets of data which are to be manipulated. Main tool for integration of CAD-subsystems in plant engineering should be a central database which is described by characteristical requirements and a possible simple conceptual schema. The main features of an interactive system for computer aided plant engineering are shortly illustrated by two examples. The analysis leads to the conclusion, that an interactive graphic system for manipulation of net-like structured data, usable for various subtasks, should be the base for computer aided plant engineering. (orig.) [de

  4. Computer aided virtual manufacturing using Creo parametric easy to learn step by step guide

    CERN Document Server

    Kanife, Paul Obiora

    2016-01-01

    Providing a step-by-step guide for the implementation of virtual manufacturing using Creo Parametric software (formerly known as Pro-Engineer), this book creates an engaging and interactive learning experience for manufacturing engineering students. Featuring graphic illustrations of simulation processes and operations, and written in accessible English to promote user-friendliness, the book covers key topics in the field including: the engraving machining process, face milling, profile milling, surface milling, volume rough milling, expert machining, electric discharge machining (EDM), and area turning using the lathe machining process. Maximising reader insights into how to simulate material removal processes, and how to generate cutter location data and G-codes data, this valuable resource equips undergraduate, postgraduate, BTech and HND students in the fields of manufacturing engineering, computer aided design (CAD) and computer aided engineering (CAE) with transferable skills and knowledge. This book is...

  5. Textural kinetics: a novel dynamic contrast-enhanced (DCE)-MRI feature for breast lesion classification.

    Science.gov (United States)

    Agner, Shannon C; Soman, Salil; Libfeld, Edward; McDonald, Margie; Thomas, Kathleen; Englander, Sarah; Rosen, Mark A; Chin, Deanna; Nosher, John; Madabhushi, Anant

    2011-06-01

    Dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) of the breast has emerged as an adjunct imaging tool to conventional X-ray mammography due to its high detection sensitivity. Despite the increasing use of breast DCE-MRI, specificity in distinguishing malignant from benign breast lesions is low, and interobserver variability in lesion classification is high. The novel contribution of this paper is in the definition of a new DCE-MRI descriptor that we call textural kinetics, which attempts to capture spatiotemporal changes in breast lesion texture in order to distinguish malignant from benign lesions. We qualitatively and quantitatively demonstrated on 41 breast DCE-MRI studies that textural kinetic features outperform signal intensity kinetics and lesion morphology features in distinguishing benign from malignant lesions. A probabilistic boosting tree (PBT) classifier in conjunction with textural kinetic descriptors yielded an accuracy of 90%, sensitivity of 95%, specificity of 82%, and an area under the curve (AUC) of 0.92. Graph embedding, used for qualitative visualization of a low-dimensional representation of the data, showed the best separation between benign and malignant lesions when using textural kinetic features. The PBT classifier results and trends were also corroborated via a support vector machine classifier which showed that textural kinetic features outperformed the morphological, static texture, and signal intensity kinetics descriptors. When textural kinetic attributes were combined with morphologic descriptors, the resulting PBT classifier yielded 89% accuracy, 99% sensitivity, 76% specificity, and an AUC of 0.91.

  6. Computer-Aided Modeling of Lipid Processing Technology

    DEFF Research Database (Denmark)

    Diaz Tovar, Carlos Axel

    2011-01-01

    increase along with growing interest in biofuels, the oleochemical industry faces in the upcoming years major challenges in terms of design and development of better products and more sustainable processes to make them. Computer-aided methods and tools for process synthesis, modeling and simulation...... are widely used for design, analysis, and optimization of processes in the chemical and petrochemical industries. These computer-aided tools have helped the chemical industry to evolve beyond commodities toward specialty chemicals and ‘consumer oriented chemicals based products’. Unfortunately...... to develop systematic computer-aided methods (property models) and tools (database) related to the prediction of the necessary physical properties suitable for design and analysis of processes employing lipid technologies. The methods and tools include: the development of a lipid-database (CAPEC...

  7. Computer-aided engineering of semiconductor integrated circuits

    Science.gov (United States)

    Meindl, J. D.; Dutton, R. W.; Gibbons, J. F.; Helms, C. R.; Plummer, J. D.; Tiller, W. A.; Ho, C. P.; Saraswat, K. C.; Deal, B. E.; Kamins, T. I.

    1980-07-01

    Economical procurement of small quantities of high performance custom integrated circuits for military systems is impeded by inadequate process, device and circuit models that handicap low cost computer aided design. The principal objective of this program is to formulate physical models of fabrication processes, devices and circuits to allow total computer-aided design of custom large-scale integrated circuits. The basic areas under investigation are (1) thermal oxidation, (2) ion implantation and diffusion, (3) chemical vapor deposition of silicon and refractory metal silicides, (4) device simulation and analytic measurements. This report discusses the fourth year of the program.

  8. Computer-aided diagnosis and artificial intelligence in clinical imaging.

    Science.gov (United States)

    Shiraishi, Junji; Li, Qiang; Appelbaum, Daniel; Doi, Kunio

    2011-11-01

    Computer-aided diagnosis (CAD) is rapidly entering the radiology mainstream. It has already become a part of the routine clinical work for the detection of breast cancer with mammograms. The computer output is used as a "second opinion" in assisting radiologists' image interpretations. The computer algorithm generally consists of several steps that may include image processing, image feature analysis, and data classification via the use of tools such as artificial neural networks (ANN). In this article, we will explore these and other current processes that have come to be referred to as "artificial intelligence." One element of CAD, temporal subtraction, has been applied for enhancing interval changes and for suppressing unchanged structures (eg, normal structures) between 2 successive radiologic images. To reduce misregistration artifacts on the temporal subtraction images, a nonlinear image warping technique for matching the previous image to the current one has been developed. Development of the temporal subtraction method originated with chest radiographs, with the method subsequently being applied to chest computed tomography (CT) and nuclear medicine bone scans. The usefulness of the temporal subtraction method for bone scans was demonstrated by an observer study in which reading times and diagnostic accuracy improved significantly. An additional prospective clinical study verified that the temporal subtraction image could be used as a "second opinion" by radiologists with negligible detrimental effects. ANN was first used in 1990 for computerized differential diagnosis of interstitial lung diseases in CAD. Since then, ANN has been widely used in CAD schemes for the detection and diagnosis of various diseases in different imaging modalities, including the differential diagnosis of lung nodules and interstitial lung diseases in chest radiography, CT, and position emission tomography/CT. It is likely that CAD will be integrated into picture archiving and

  9. Image-processing techniques used in the computer-aided detection of radiographic lesions in anatomic background

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.; Yin, F.F.

    1988-01-01

    The authors developed feature-extraction techniques for use in the computer-aided detection of pulmonary nodules in digital chest images. Use of such a computer-aided detection scheme, which would alert radiologists to the locations of suspected lung nodules, is expected to reduce the number of false-negative diagnoses. False-negative diagnoses (i.e., misses) are a current problem in chest radiology with ''miss-rates'' as high as 30%. This may be due to the camouflaging effect of surrounding anatomic background on the nodule, or to the subjective and varying decision criteria used by radiologists

  10. Cafts: computer aided fault tree analysis

    International Nuclear Information System (INIS)

    Poucet, A.

    1985-01-01

    The fault tree technique has become a standard tool for the analysis of safety and reliability of complex system. In spite of the costs, which may be high for a complete and detailed analysis of a complex plant, the fault tree technique is popular and its benefits are fully recognized. Due to this applications of these codes have mostly been restricted to simple academic examples and rarely concern complex, real world systems. In this paper an interactive approach to fault tree construction is presented. The aim is not to replace the analyst, but to offer him an intelligent tool which can assist him in modeling complex systems. Using the CAFTS-method, the analyst interactively constructs a fault tree in two phases: (1) In a first phase he generates an overall failure logic structure of the system; the macrofault tree. In this phase, CAFTS features an expert system approach to assist the analyst. It makes use of a knowledge base containing generic rules on the behavior of subsystems and components; (2) In a second phase the macrofault tree is further refined and transformed in a fully detailed and quantified fault tree. In this phase a library of plant-specific component failure models is used

  11. Computer-aided Fault Tree Analysis

    International Nuclear Information System (INIS)

    Willie, R.R.

    1978-08-01

    A computer-oriented methodology for deriving minimal cut and path set families associated with arbitrary fault trees is discussed first. Then the use of the Fault Tree Analysis Program (FTAP), an extensive FORTRAN computer package that implements the methodology is described. An input fault tree to FTAP may specify the system state as any logical function of subsystem or component state variables or complements of these variables. When fault tree logical relations involve complements of state variables, the analyst may instruct FTAP to produce a family of prime implicants, a generalization of the minimal cut set concept. FTAP can also identify certain subsystems associated with the tree as system modules and provide a collection of minimal cut set families that essentially expresses the state of the system as a function of these module state variables. Another FTAP feature allows a subfamily to be obtained when the family of minimal cut sets or prime implicants is too large to be found in its entirety; this subfamily consists only of sets that are interesting to the analyst in a special sense

  12. [Key points for esthetic rehabilitation of anterior teeth using chair-side computer aided design and computer aided manufacture technique].

    Science.gov (United States)

    Yang, J; Feng, H L

    2018-04-09

    With the rapid development of the chair-side computer aided design and computer aided manufacture (CAD/CAM) technology, its accuracy and operability of have been greatly improved in recent years. Chair-side CAD/CAM system may produce all kinds of indirect restorations, and has the advantages of rapid, accurate and stable production. It has become the future development direction of Stomatology. This paper describes the clinical application of the chair-side CAD/CAM technology for anterior aesthetic restorations from the aspects of shade and shape.

  13. Improved mammographic interpretation of masses using computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Leichter, I. [Dept. of Electro-Optics, Jerusalem College of Technology (Israel); Fields, S.; Novak, B. [Dept. of Radiology, Hadassah University Hospital, Mt. Scopus Jerusalem (Israel); Nirel, R. [Dept. of Statistics, Hebrew University of Jerusalem, Mt. Scopus, Jerusalem (Israel); Bamberger, P. [Dept. of Electronics, Jerusalem College of Technology, Jerusalem (Israel); Lederman, R. [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Buchbinder, S. [Department of Radiology, Montefiore Medical Center, University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States)

    2000-02-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p < 0.005) was found between features extracted by the CAD system for benign and malignant cases. Specificity of the CAD-assisted diagnosis improved significantly (p < 0.02) from 14 % for the conventional assessment to 50 %, and the positive predictive value increased from 0.47 to 0.62 (p < 0.04). The area under the ROC curve (A{sub z}) increased significantly (p < 0.001) from 0.66 for the conventional assessment to 0.81 for the CAD-assisted analysis. The A{sub z} for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that

  14. New design methods for computer aided architecturald design methodology teaching

    NARCIS (Netherlands)

    Achten, H.H.

    2003-01-01

    Architects and architectural students are exploring new ways of design using Computer Aided Architectural Design software. This exploration is seldom backed up from a design methodological viewpoint. In this paper, a design methodological framework for reflection on innovate design processes by

  15. Critiquing the Computer-Aided Design of Dental Prostheses.

    Science.gov (United States)

    Fitzpatrick, F. J.; And Others

    This paper describes RaPiD, a computer-aided assistant for the design of dental prostheses called removable partial dentures. The user manipulates icons directly to indicate the desired design solution to a given clinical situation. A developing design is represented as a logic database of components in a design; expert rules are applied as…

  16. Computer-aided discovery of antimicrobial agents as potential enoyl ...

    African Journals Online (AJOL)

    Computer-aided discovery of antimicrobial agents as potential enoyl acyl carrier protein reductase inhibitors. ... Conclusion: Overall, the newly discovered hits can act as a good starting point in the future for the development of safe and potent antibacterial agents. Keywords: Enoyl acyl carrier protein reductase, saFabI, ...

  17. Assisted supervision of a computer aided tele-operation system

    Energy Technology Data Exchange (ETDEWEB)

    Le Bars, H; Gravez, P; Fournier, R

    1994-12-31

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs.

  18. Assisted supervision of a computer aided tele-operation system

    International Nuclear Information System (INIS)

    Le Bars, H.; Gravez, P.; Fournier, R.

    1994-01-01

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs

  19. COMPUTER-AIDED DATA ACQUISITION FOR COMBUSTION EXPERIMENTS

    Science.gov (United States)

    The article describes the use of computer-aided data acquisition techniques to aid the research program of the Combustion Research Branch (CRB) of the U.S. EPA's Air and Energy Engineering Research Laboratory (AEERL) in Research Triangle Park, NC, in particular on CRB's bench-sca...

  20. A Complete Interactive Graphical Computer-Aided Instruction System.

    Science.gov (United States)

    Abrams, Steven Selby

    The use of interactive graphics in computer-aided instruction systems is discussed with emphasis placed on two requirements of such a system. The first is the need to provide the teacher with a useful tool with which to design and modify teaching sessions tailored to the individual needs and capabilities of the students. The second is the…

  1. DEVELOPMENT OF COMPUTER AIDED DESIGN OF CHAIN COUPLING

    Directory of Open Access Journals (Sweden)

    Sergey Aleksandrovich Sergeev

    2015-12-01

    Full Text Available The present paper describes the development stages of computer-aided design of chain couplings. The first stage is the automation of traditional design techniques (intermediate automation. The second integrated automation with the development of automated equipment and production technology, including on the basis of flexible manufacturing systems (high level of automation.

  2. National Survey of Computer Aided Manufacturing in Industrial Technology Programs.

    Science.gov (United States)

    Heidari, Farzin

    The current status of computer-aided manufacturing in the 4-year industrial technology programs in the United States was studied. All industrial technology department chairs were mailed a questionnaire divided into program information, equipment information, and general comments sections. The questionnaire was designed to determine the subjects…

  3. Computer-Aided Test Flow in Core-Based Design

    NARCIS (Netherlands)

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the efficient test-pattern generation in a core-based design. A consistent Computer-Aided Test (CAT) flow is proposed based on the required core-test strategy. It generates a test-pattern set for the embedded cores with high fault coverage and low DfT area overhead. The CAT

  4. Computer-Aided Test Flow in Core-Based Design

    NARCIS (Netherlands)

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the test-pattern generation and fault coverage determination in the core based design. The basic core-test strategy that one has to apply in the core-based design is stated in this work. A Computer-Aided Test (CAT) flow is proposed resulting in accurate fault coverage of

  5. Computer-aided engineering for Qinshan CANDU projects

    International Nuclear Information System (INIS)

    Huang Zhizhang; Goland, D.

    1999-01-01

    The author briefly describes AECL's work in applying computer-aided engineering tools to the Qinshan CANDU Project. The main emphases will be to introduce the major CADD software tools and their use in civil design, process design and EI and C design. Other special software tools and non-CADD tools and their applications are also briefly introduced

  6. Computer Aided Education System SuperTest. Present and Prospective

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available This paper analyzes the testing and self-testing process for the Computer Aided Education System (CAES SuperTest, used at the Academy of Economic Studies of Chisinau, Moldova and recently implemented at the University of Bacau, Romania. We discuss here the future of this software, from the Information Society and Knowledge Society point of view.

  7. Computer-Aided Multiscale Modelling for Chemical Process Engineering

    DEFF Research Database (Denmark)

    Morales Rodriguez, Ricardo; Gani, Rafiqul

    2007-01-01

    Chemical processes are generally modeled through monoscale approaches, which, while not adequate, satisfy a useful role in product-process design. In this case, use of a multi-dimensional and multi-scale model-based approach has importance in product-process development. A computer-aided framework...

  8. The University of Michigan's Computer-Aided Engineering Network.

    Science.gov (United States)

    Atkins, D. E.; Olsen, Leslie A.

    1986-01-01

    Presents an overview of the Computer-Aided Engineering Network (CAEN) of the University of Michigan. Describes its arrangement of workstations, communication networks, and servers. Outlines the factors considered in hardware and software decision making. Reviews the program's impact on students. (ML)

  9. Computer-Aided Template for Model Reuse, Development and Maintenance

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    2014-01-01

    A template-based approach for model development is presented in this work. Based on a model decomposition technique, the computer-aided template concept has been developed. This concept is implemented as a software tool , which provides a user-friendly interface for following the workflow steps...

  10. Caesy: A software tool for computer-aided engineering

    Science.gov (United States)

    Wette, Matt

    1993-01-01

    A new software tool, Caesy, is described. This tool provides a strongly typed programming environment for research in the development of algorithms and software for computer-aided control system design. A description of the user language and its implementation as they currently stand are presented along with a description of work in progress and areas of future work.

  11. Software Engineering Techniques for Computer-Aided Learning.

    Science.gov (United States)

    Ibrahim, Bertrand

    1989-01-01

    Describes the process for developing tutorials for computer-aided learning (CAL) using a programing language rather than an authoring system. The workstation used is described, the use of graphics is discussed, the role of a local area network (LAN) is explained, and future plans are discussed. (five references) (LRW)

  12. Computer-aided voice training in higher education: participants ...

    African Journals Online (AJOL)

    The training of performance singing in a multi lingual, multi cultural educational context presents unique problems and requires inventive teaching strategies. Computer-aided training offers objective visual feedback of the voice production that can be implemented as a teaching aid in higher education. This article reports on ...

  13. Students' perceptions of a multimedia computer-aided instruction ...

    African Journals Online (AJOL)

    Objective. To develop an interactive muttimedia-based computer-aided instruction (CAI) programme, to detennine its educational worth and efficacy in a multicuttural academic environment and to evaluate its usage by students with differing levels of computer literacy. Design. A prospective descriptive study evaluating ...

  14. Method of Computer-aided Instruction in Situation Control Systems

    Directory of Open Access Journals (Sweden)

    Anatoliy O. Kargin

    2013-01-01

    Full Text Available The article considers the problem of computer-aided instruction in context-chain motivated situation control system of the complex technical system behavior. The conceptual and formal models of situation control with practical instruction are considered. Acquisition of new behavior knowledge is presented as structural changes in system memory in the form of situational agent set. Model and method of computer-aided instruction represent formalization, based on the nondistinct theories by physiologists and cognitive psychologists.The formal instruction model describes situation and reaction formation and dependence on different parameters, effecting education, such as the reinforcement value, time between the stimulus, action and the reinforcement. The change of the contextual link between situational elements when using is formalized.The examples and results of computer instruction experiments of the robot device “LEGO MINDSTORMS NXT”, equipped with ultrasonic distance, touch, light sensors.

  15. Computer-aided dental prostheses construction using reverse engineering.

    Science.gov (United States)

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  16. Mineral compactness of vertebrae in Russian population in health according to quantitative computer-aided tomography

    International Nuclear Information System (INIS)

    Vlasova, I.S.; Sorokin, A.D.; Gorbatov, M.M.; Vozhagov, V.V.; Ternovoj, S.K.

    1998-01-01

    To create a reference database for residents of Central Russia and estimate the rate of calcium loss by bone tissue the mineral compactness of vertebral trabecular substance was studied by quantitative computer-aided tomography in 1061 subjects (610 females and 451 males aged 12-89 and 7-91 years, respectively) without somatic diseases and taking no drugs affecting osseous metabolism. Comparison of mineral bone density (MCB) regression curves in residents of Central Russia and of the values provided by producer firms shows differences in calcium content of vertebral trabecular substance, which can be due to specific ethnic features of different populations, lifestyle, and nutrition habits [ru

  17. Computer-Aided Diagnosis Systems for Brain Diseases in Magnetic Resonance Images

    Directory of Open Access Journals (Sweden)

    Yasuo Yamashita

    2009-07-01

    Full Text Available This paper reviews the basics and recent researches of computer-aided diagnosis (CAD systems for assisting neuroradiologists in detection of brain diseases, e.g., asymptomatic unruptured aneurysms, Alzheimer's disease, vascular dementia, and multiple sclerosis (MS, in magnetic resonance (MR images. The CAD systems consist of image feature extraction based on image processing techniques and machine learning classifiers such as linear discriminant analysis, artificial neural networks, and support vector machines. We introduce useful examples of the CAD systems in the neuroradiology, and conclude with possibilities in the future of the CAD systems for brain diseases in MR images.

  18. Computer-aided detection of lung nodules in digital chest radiographs

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.M.

    1986-01-01

    The authors are developing an automated method to detect lung nodules by eliminating the ''camouflaging: effect of the lung background. In order to increase the conspicuity of the nodules, we created, from a single chest radiograph, two images: one in which the signal-to-noise ratio (S/N) of the nodule is maximized and another in which that S/N is suppressed. The difference between these two processed images was subjected to feature-extraction technique in order to isolate the nodules. The detection accuracy of the computer-aided detection scheme, as compared with unaided radiologists' performance, was determined using receiver operating characteristic curve analysis

  19. A study on NMI report generation with computer aid diagnosis

    International Nuclear Information System (INIS)

    Yang Xiaona; Li Zhimin; Zhao Xiangjun; Qiu Jinping

    1994-01-01

    An expert system of intelligent diagnosis, computer aid diagnosis and computerized report generation and management for an nuclear medicine imaging (NMI) was performed. The mathematic model with finite set mapping for the diagnosis was evaluated. The clinical application shows, the diagnostic sensitivity and specificity of it was 85.7% ∼ 93.4% and 92% ∼ 95.6% respectively. Therefore, its application may be extended

  20. Computer Aided Multi-Data Fusion Dismount Modeling

    Science.gov (United States)

    2012-03-22

    dependent on a particular environmental condition. They are costly, cumbersome, and involve dedicated software practices and particular knowledge to operate...allow manipulation of 2D matrices, like Microsoft Excel or Libre Office. The second alternative is to modify an already created model (MEM). The model... software . Therefore, with the described computer aided multi-data dismount model the researcher will be able to attach signatures to any desired

  1. Contributions on Computer Aided Manufacturing of Drill-Jig Bushings

    Directory of Open Access Journals (Sweden)

    Vasile Cojocaru

    2009-01-01

    Full Text Available The paper presents the steps for computer aided manufacturing (CAMof the bushings technological class parts: design of the part in CADsoftware; generation of the parametrical link with MSExcel files; extract of the useful information for the technological design (mass, volume, surfaces; setting of the CNC lathe and necessary tools; programming of the CNC code for manufacturing. Given the large variety of the bushingsshapes and dimensions, the application focused on the jig bushings used in drilling processes.

  2. Evaluation of computer-aided detection and diagnosis systems.

    Science.gov (United States)

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in

  3. Modeling electric fields in two dimensions using computer aided design

    International Nuclear Information System (INIS)

    Gilmore, D.W.; Giovanetti, D.

    1992-01-01

    The authors describe a method for analyzing static electric fields in two dimensions using AutoCAD. The algorithm is coded in LISP and is modeled after Coloumb's Law. The software platform allows for facile graphical manipulations of field renderings and supports a wide range of hardcopy-output and data-storage formats. More generally, this application is representative of the ability to analyze data that is the solution to known mathematical functions with computer aided design (CAD)

  4. Computer-Aided Test Flow in Core-Based Design

    OpenAIRE

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the test-pattern generation and fault coverage determination in the core based design. The basic core-test strategy that one has to apply in the core-based design is stated in this work. A Computer-Aided Test (CAT) flow is proposed resulting in accurate fault coverage of embedded cores. The CAT now is applied to a few cores within the Philips Core Test Pilot IC project

  5. Computer-aided design and computer science technology

    Science.gov (United States)

    Fulton, R. E.; Voigt, S. J.

    1976-01-01

    A description is presented of computer-aided design requirements and the resulting computer science advances needed to support aerospace design. The aerospace design environment is examined, taking into account problems of data handling and aspects of computer hardware and software. The interactive terminal is normally the primary interface between the computer system and the engineering designer. Attention is given to user aids, interactive design, interactive computations, the characteristics of design information, data management requirements, hardware advancements, and computer science developments.

  6. Database organization for computer-aided characterization of laser diode

    International Nuclear Information System (INIS)

    Oyedokun, Z.O.

    1988-01-01

    Computer-aided data logging involves a huge amount of data which must be properly managed for optimized storage space, easy access, retrieval and utilization. An organization method is developed to enhance the advantages of computer-based data logging of the testing of the semiconductor injection laser which optimize storage space, permit authorized user easy access and inhibits penetration. This method is based on unique file identification protocol tree structure and command file-oriented access procedures

  7. CADRIGS--computer aided design reliability interactive graphics system

    International Nuclear Information System (INIS)

    Kwik, R.J.; Polizzi, L.M.; Sticco, S.; Gerrard, P.B.; Yeater, M.L.; Hockenbury, R.W.; Phillips, M.A.

    1982-01-01

    An integrated reliability analysis program combining graphic representation of fault trees, automated data base loadings and reference, and automated construction of reliability code input files was developed. The functional specifications for CADRIGS, the computer aided design reliability interactive graphics system, are presented. Previously developed fault tree segments used in auxiliary feedwater system safety analysis were constructed on CADRIGS and, when combined, yielded results identical to those resulting from manual input to the same reliability codes

  8. An Integrated Computer-Aided Approach for Environmental Studies

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Chen, Fei; Jaksland, Cecilia

    1997-01-01

    A general framework for an integrated computer-aided approach to solve process design, control, and environmental problems simultaneously is presented. Physicochemical properties and their relationships to the molecular structure play an important role in the proposed integrated approach. The sco...... and applicability of the integrated approach is highlighted through examples involving estimation of properties and environmental pollution prevention. The importance of mixture effects on some environmentally important properties is also demonstrated....

  9. The computer-aided design of rubber-metal products

    Directory of Open Access Journals (Sweden)

    Pavlo S. Shvets

    2015-12-01

    Full Text Available The important problem in design of rubber-metal products is the optimization of their mass without sacrificing of proportionality factor is in the limits of standard. Aim: The aim of this work is to improve the computer-aided systems by development and implementation of improved optimization method in rubber-metal CAD systems for designers based on the reverse optimization. Materials and Methods: The paper studies the matters of computer-aided structural design of technical composite products composed of anisotropic materials that are essentially different in properties. Results: The structure of CAD systems for designers solving the problems of such design is offered and the work principles of its subsystems are described. It is shown that complicated systems optimization in CAD systems must consider as restrictions the entitative connection between separate elements of these systems within the area of the optimizing arguments. Conclusions: The problem of the “reverse” optimization when objective functions are the connectivity area parameters is considered. In many cases, this allows receiving solutions that are more effective during the computer-aided design process. The developed CAD system for designers was used during the production of rubber-metal shock absorbers at the Odessa Rubber Technical Articles Plant. The positive technical and economic effect was obtained.

  10. Vascular tissue engineering by computer-aided laser micromachining.

    Science.gov (United States)

    Doraiswamy, Anand; Narayan, Roger J

    2010-04-28

    Many conventional technologies for fabricating tissue engineering scaffolds are not suitable for fabricating scaffolds with patient-specific attributes. For example, many conventional technologies for fabricating tissue engineering scaffolds do not provide control over overall scaffold geometry or over cell position within the scaffold. In this study, the use of computer-aided laser micromachining to create scaffolds for vascular tissue networks was investigated. Computer-aided laser micromachining was used to construct patterned surfaces in agarose or in silicon, which were used for differential adherence and growth of cells into vascular tissue networks. Concentric three-ring structures were fabricated on agarose hydrogel substrates, in which the inner ring contained human aortic endothelial cells, the middle ring contained HA587 human elastin and the outer ring contained human aortic vascular smooth muscle cells. Basement membrane matrix containing vascular endothelial growth factor and heparin was to promote proliferation of human aortic endothelial cells within the vascular tissue networks. Computer-aided laser micromachining provides a unique approach to fabricate small-diameter blood vessels for bypass surgery as well as other artificial tissues with complex geometries.

  11. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks.

    Science.gov (United States)

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes

    2013-09-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.

  12. Correction of facial and mandibular asymmetry using a computer aided design/computer aided manufacturing prefabricated titanium implant.

    Science.gov (United States)

    Watson, Jason; Hatamleh, Muhanad; Alwahadni, Ahed; Srinivasan, Dilip

    2014-05-01

    Patients with significant craniofacial asymmetry may have functional problems associated with their occlusion and aesthetic concerns related to the imbalance in soft and hard tissue profiles. This report details a case of facial asymmetry secondary to left mandible angle deficiency due to undergoing previous radiotherapy. We describe the correction of the bony deformity using computer aided design/computer aided manufacturing custom-made titanium onlay using novel direct metal laser sintering. The direct metal laser sintering onlay proved a very accurate operative fit and showed a good aesthetic correction of the bony defect with no reported complications postoperatively. It is a useful low-morbidity technique, and there is no resorption or associated donor-site complications.

  13. To the problem of reliability standardization in computer-aided manufacturing at NPP units

    International Nuclear Information System (INIS)

    Yastrebenetskij, M.A.; Shvyryaev, Yu.V.; Spektor, L.I.; Nikonenko, I.V.

    1989-01-01

    The problems of reliability standardization in computer-aided manufacturing of NPP units considering the following approaches: computer-aided manufacturing of NPP units as a part of automated technological complex; computer-aided manufacturing of NPP units as multi-functional system, are analyzed. Selection of the composition of reliability indeces for computer-aided manufacturing of NPP units for each of the approaches considered is substantiated

  14. Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) |

    Science.gov (United States)

    Transportation Research | NREL Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Computer-Aided Engineering for Electric-Drive Vehicle Batteries (CAEBAT) Graphic of a 24-cell (bottom). Images: Courtesy of EC Power NREL's work on the U.S. Department of Energy Computer-Aided

  15. Reduced Chemical Kinetic Mechanisms for JP-8 Combustion

    National Research Council Canada - National Science Library

    Montgomery, Christopher J; Cannon, S. M; Mawid, M. A; Sekar, B

    2002-01-01

    Using CARM (Computer Aided Reduction Method), a computer program that automates the mechanism reduction process, six different reduced chemical kinetic mechanisms for JP-8 combustion have been generated...

  16. Computer-aided detection of basal cell carcinoma through blood content analysis in dermoscopy images

    Science.gov (United States)

    Kharazmi, Pegah; Kalia, Sunil; Lui, Harvey; Wang, Z. Jane; Lee, Tim K.

    2018-02-01

    Basal cell carcinoma (BCC) is the most common type of skin cancer, which is highly damaging to the skin at its advanced stages and causes huge costs on the healthcare system. However, most types of BCC are easily curable if detected at early stage. Due to limited access to dermatologists and expert physicians, non-invasive computer-aided diagnosis is a viable option for skin cancer screening. A clinical biomarker of cancerous tumors is increased vascularization and excess blood flow. In this paper, we present a computer-aided technique to differentiate cancerous skin tumors from benign lesions based on vascular characteristics of the lesions. Dermoscopy image of the lesion is first decomposed using independent component analysis of the RGB channels to derive melanin and hemoglobin maps. A novel set of clinically inspired features and ratiometric measurements are then extracted from each map to characterize the vascular properties and blood content of the lesion. The feature set is then fed into a random forest classifier. Over a dataset of 664 skin lesions, the proposed method achieved an area under ROC curve of 0.832 in a 10-fold cross validation for differentiating basal cell carcinomas from benign lesions.

  17. Computer-aided diagnosis of early knee osteoarthritis based on MRI T2 mapping.

    Science.gov (United States)

    Wu, Yixiao; Yang, Ran; Jia, Sen; Li, Zhanjun; Zhou, Zhiyang; Lou, Ting

    2014-01-01

    This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.

  18. [Computer-aided prescribing: from utopia to reality].

    Science.gov (United States)

    Suárez-Varela Ubeda, J; Beltrán Calvo, C; Molina López, T; Navarro Marín, P

    2005-05-31

    To determine whether the introduction of computer-aided prescribing helped reduce the administrative burden at primary care centers. Descriptive, cross-sectional design. Torreblanca Health Center in the province of Seville, southern Spain. From 29 October 2003 to the present a pilot project involving nine pharmacies in the basic health zone served by this health center has been running to evaluate computer-aided prescribing (the Receta XXI project) with real patients. All patients on the center's list of patients who came to the center for an administrative consultation to renew prescriptions for medications or supplies for long-term treatment. Total number of administrative visits per patient for patients who came to the center to renew prescriptions for long-term treatment, as recorded by the Diraya system (Historia Clinica Digital del Ciudadano, or Citizen's Digital Medical Record) during the period from February to July 2004. Total number of the same type of administrative visits recorded by the previous system (TASS) during the period from February to July 2003. The mean number of administrative visits per month during the period from February to July 2003 was 160, compared to a mean number of 64 visits during the period from February to July 2004. The reduction in the number of visits for prescription renewal was 60%. Introducing a system for computer-aided prescribing significantly reduced the number of administrative visits for prescription renewal for long-term treatment. This could help reduce the administrative burden considerably in primary care if the system were used in all centers.

  19. Computer aided detection of surgical retained foreign object for prevention

    International Nuclear Information System (INIS)

    Hadjiiski, Lubomir; Marentis, Theodore C.; Rondon, Lucas; Chan, Heang-Ping; Chaudhury, Amrita R.; Chronis, Nikolaos

    2015-01-01

    Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10 9 annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for the surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96

  20. 9th Asian Conference on Computer-Aided Surgery

    CERN Document Server

    2016-01-01

    This book presents the latest research advances in the theory, design, control, and application of robot systems intended for a variety of purposes such as manipulation, manufacturing, automation, surgery, locomotion, and biomechanics. Several chapters deal with fundamental kinematics in nature, including synthesis, calibration, redundancy, force control, dexterity, inverse and forward kinematics, kinematic singularities, and over-constrained systems. This book is a compilation of the extended versions of the very best papers selected from the many that were presented at the Asian Conference on Computer-Aided Surgery held September 16–18, 2013, in Tokyo, Japan (ACCAS 2013).

  1. A fast algorithm for computer aided collimation gamma camera (CACAO)

    Science.gov (United States)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Franck, D.; Pihet, P.; Ballongue, P.

    2000-08-01

    The computer aided collimation gamma camera is aimed at breaking down the resolution sensitivity trade-off of the conventional parallel hole collimator. It uses larger and longer holes, having an added linear movement at the acquisition sequence. A dedicated algorithm including shift and sum, deconvolution, parabolic filtering and rotation is described. Examples of reconstruction are given. This work shows that a simple and fast algorithm, based on a diagonal dominant approximation of the problem can be derived. Its gives a practical solution to the CACAO reconstruction problem.

  2. Computer aided approach for qualitative risk assessment of engineered systems

    International Nuclear Information System (INIS)

    Crowley, W.K.; Arendt, J.S.; Fussell, J.B.; Rooney, J.J.; Wagner, D.P.

    1978-01-01

    This paper outlines a computer aided methodology for determining the relative contributions of various subsystems and components to the total risk associated with an engineered system. Major contributors to overall task risk are identified through comparison of an expected frequency density function with an established risk criterion. Contributions that are inconsistently high are also identified. The results from this analysis are useful for directing efforts for improving system safety and performance. An analysis of uranium hexafluoride handling risk at a gaseous diffusion uranium enrichment plant using a preliminary version of the computer program EXCON is briefly described and illustrated

  3. Technology computer aided design simulation for VLSI MOSFET

    CERN Document Server

    Sarkar, Chandan Kumar

    2013-01-01

    Responding to recent developments and a growing VLSI circuit manufacturing market, Technology Computer Aided Design: Simulation for VLSI MOSFET examines advanced MOSFET processes and devices through TCAD numerical simulations. The book provides a balanced summary of TCAD and MOSFET basic concepts, equations, physics, and new technologies related to TCAD and MOSFET. A firm grasp of these concepts allows for the design of better models, thus streamlining the design process, saving time and money. This book places emphasis on the importance of modeling and simulations of VLSI MOS transistors and

  4. Computer-aided design of bromelain and papain covalent immobilization

    OpenAIRE

    Bessy Cutiño-Avila; Dayrom Gil Pradas; Carlos Aragón Abreu; Yuniel Fernández Marrero; Martha Hernández de la Torre; Emir Salas Sarduy; María de los Ángeles Chávez Planes; José Manuel Guisán Seijas; Joaquín Díaz Brito; Alberto del Monte-Martínez

    2014-01-01

    Título en español: Diseño asistido por computadora de la inmovilización covalente de bromelina y papaína. Título corto: Computer-aided design of bromelain and papain.  Abstract: Enzymes as immobilized derivatives have been widely used in Food, Agrochemical, Pharmaceutical and Biotechnological industries. Protein immobilization is probably the most used technology to improve the operational stability of these molecules. Bromelain (Ananas comosus) and papain (Carica papaya) are cystein pr...

  5. Computer aided system for parametric design of combination die

    Science.gov (United States)

    Naranje, Vishal G.; Hussein, H. M. A.; Kumar, S.

    2017-09-01

    In this paper, a computer aided system for parametric design of combination dies is presented. The system is developed using knowledge based system technique of artificial intelligence. The system is capable to design combination dies for production of sheet metal parts having punching and cupping operations. The system is coded in Visual Basic and interfaced with AutoCAD software. The low cost of the proposed system will help die designers of small and medium scale sheet metal industries for design of combination dies for similar type of products. The proposed system is capable to reduce design time and efforts of die designers for design of combination dies.

  6. The computer aided education and training system for accident management

    International Nuclear Information System (INIS)

    Yoneyama, Mitsuru; Kubota, Ryuji; Fujiwara, Tadashi; Sakuma, Hitoshi

    1999-01-01

    The education and training system for Accident Management was developed by the Japanese BWR group and Hitachi Ltd. The education and training system is composed of two systems. One is computer aided instruction (CAI) education system and the education and training system with computer simulations. Both systems are designed to be executed on personal computers. The outlines of the CAI education system and the education and training system with simulator are reported below. These systems provides plant operators and technical support center staff with the effective education and training for accident management. (author)

  7. Computer-aided design of new metal binders

    International Nuclear Information System (INIS)

    Varnek, A.; Fourches, D.; Klimchuk, O.; Marcou, G.; Kireeva, N.; Tsivadze, A.; Solov'ev, V.

    2008-01-01

    Chemoinformatics approaches open new opportunities for computer-aided design of new efficient metal binders. Here, we demonstrate performances of ISIDA and COMET software tools to predict stability constants (log K) of the metal ion/organic ligand complexes in solution and to design in silico new molecules possessing desirable properties. The predictive models for log K of lanthanides complexation in water have been developed. Some new uranyl binders based on monoamides and on phosphoryl-containing podands were suggested theoretically, then synthesized and tested experimentally. Reasonable agreement between experimental uranyl distribution coefficients and theoretically predicted values has been observed. (orig.)

  8. Efficient Use of Preisach Hysteresis Model in Computer Aided Design

    Directory of Open Access Journals (Sweden)

    IONITA, V.

    2013-05-01

    Full Text Available The paper presents a practical detailed analysis regarding the use of the classical Preisach hysteresis model, covering all the steps, from measuring the necessary data for the model identification to the implementation in a software code for Computer Aided Design (CAD in Electrical Engineering. An efficient numerical method is proposed and the hysteresis modeling accuracy is tested on magnetic recording materials. The procedure includes the correction of the experimental data, which are used for the hysteresis model identification, taking into account the demagnetizing effect for the sample that is measured in an open-circuit device (a vibrating sample magnetometer.

  9. Computer-aided modelling template: Concept and application

    DEFF Research Database (Denmark)

    Fedorova, Marina; Sin, Gürkan; Gani, Rafiqul

    2015-01-01

    decomposition technique which identifies generic steps and workflow involved, the computer-aided template concept has been developed. This concept is implemented as a software tool, which provides a user-friendly interface for following the workflow steps and guidance through the steps providing additional......Modelling is an important enabling technology in modern chemical engineering applications. A template-based approach is presented in this work to facilitate the construction and documentation of the models and enable their maintenance for reuse in a wider application range. Based on a model...

  10. A dimension reduction strategy for improving the efficiency of computer-aided detection for CT colonography

    Science.gov (United States)

    Song, Bowen; Zhang, Guopeng; Wang, Huafeng; Zhu, Wei; Liang, Zhengrong

    2013-02-01

    Various types of features, e.g., geometric features, texture features, projection features etc., have been introduced for polyp detection and differentiation tasks via computer aided detection and diagnosis (CAD) for computed tomography colonography (CTC). Although these features together cover more information of the data, some of them are statistically highly-related to others, which made the feature set redundant and burdened the computation task of CAD. In this paper, we proposed a new dimension reduction method which combines hierarchical clustering and principal component analysis (PCA) for false positives (FPs) reduction task. First, we group all the features based on their similarity using hierarchical clustering, and then PCA is employed within each group. Different numbers of principal components are selected from each group to form the final feature set. Support vector machine is used to perform the classification. The results show that when three principal components were chosen from each group we can achieve an area under the curve of receiver operating characteristics of 0.905, which is as high as the original dataset. Meanwhile, the computation time is reduced by 70% and the feature set size is reduce by 77%. It can be concluded that the proposed method captures the most important information of the feature set and the classification accuracy is not affected after the dimension reduction. The result is promising and further investigation, such as automatically threshold setting, are worthwhile and are under progress.

  11. NALDA (Naval Aviation Logistics Data Analysis) CAI (computer aided instruction)

    Energy Technology Data Exchange (ETDEWEB)

    Handler, B.H. (Oak Ridge K-25 Site, TN (USA)); France, P.A.; Frey, S.C.; Gaubas, N.F.; Hyland, K.J.; Lindsey, A.M.; Manley, D.O. (Oak Ridge Associated Universities, Inc., TN (USA)); Hunnum, W.H. (North Carolina Univ., Chapel Hill, NC (USA)); Smith, D.L. (Memphis State Univ., TN (USA))

    1990-07-01

    Data Systems Engineering Organization (DSEO) personnel developed a prototype computer aided instruction CAI system for the Naval Aviation Logistics Data Analysis (NALDA) system. The objective of this project was to provide a CAI prototype that could be used as an enhancement to existing NALDA training. The CAI prototype project was performed in phases. The task undertaken in Phase I was to analyze the problem and the alternative solutions and to develop a set of recommendations on how best to proceed. The findings from Phase I are documented in Recommended CAI Approach for the NALDA System (Duncan et al., 1987). In Phase II, a structured design and specifications were developed, and a prototype CAI system was created. A report, NALDA CAI Prototype: Phase II Final Report, was written to record the findings and results of Phase II. NALDA CAI: Recommendations for an Advanced Instructional Model, is comprised of related papers encompassing research on computer aided instruction CAI, newly developing training technologies, instructional systems development, and an Advanced Instructional Model. These topics were selected because of their relevancy to the CAI needs of NALDA. These papers provide general background information on various aspects of CAI and give a broad overview of new technologies and their impact on the future design and development of training programs. The paper within have been index separately elsewhere.

  12. Computer-aided auscultation learning system for nursing technique instruction.

    Science.gov (United States)

    Hou, Chun-Ju; Chen, Yen-Ting; Hu, Ling-Chen; Chuang, Chih-Chieh; Chiu, Yu-Hsien; Tsai, Ming-Shih

    2008-01-01

    Pulmonary auscultation is a physical assessment skill learned by nursing students for examining the respiratory system. Generally, a sound simulator equipped mannequin is used to group teach auscultation techniques via classroom demonstration. However, nursing students cannot readily duplicate this learning environment for self-study. The advancement of electronic and digital signal processing technologies facilitates simulating this learning environment. This study aims to develop a computer-aided auscultation learning system for assisting teachers and nursing students in auscultation teaching and learning. This system provides teachers with signal recording and processing of lung sounds and immediate playback of lung sounds for students. A graphical user interface allows teachers to control the measuring device, draw lung sound waveforms, highlight lung sound segments of interest, and include descriptive text. Effects on learning lung sound auscultation were evaluated for verifying the feasibility of the system. Fifteen nursing students voluntarily participated in the repeated experiment. The results of a paired t test showed that auscultative abilities of the students were significantly improved by using the computer-aided auscultation learning system.

  13. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K.H.; Weber, M.; Weiss, M. [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1998-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  14. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K H; Weber, M; Weiss, M [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1999-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  15. Computer-aided classification of forest cover types from small scale aerial photography

    Science.gov (United States)

    Bliss, John C.; Bonnicksen, Thomas M.; Mace, Thomas H.

    1980-11-01

    The US National Park Service must map forest cover types over extensive areas in order to fulfill its goal of maintaining or reconstructing presettlement vegetation within national parks and monuments. Furthermore, such cover type maps must be updated on a regular basis to document vegetation changes. Computer-aided classification of small scale aerial photography is a promising technique for generating forest cover type maps efficiently and inexpensively. In this study, seven cover types were classified with an overall accuracy of 62 percent from a reproduction of a 1∶120,000 color infrared transparency of a conifer-hardwood forest. The results were encouraging, given the degraded quality of the photograph and the fact that features were not centered, as well as the lack of information on lens vignetting characteristics to make corrections. Suggestions are made for resolving these problems in future research and applications. In addition, it is hypothesized that the overall accuracy is artificially low because the computer-aided classification more accurately portrayed the intermixing of cover types than the hand-drawn maps to which it was compared.

  16. Computer-Aided System of Virtual Testing of Gas Turbine Engines

    Directory of Open Access Journals (Sweden)

    Rybakov Viktor N.

    2016-01-01

    Full Text Available The article describes the concept of a virtual lab that includes subsystem of gas turbine engine simulation, subsystem of experiment planning, subsystem of measurement errors simulation, subsystem of simulator identification and others. The basis for virtual lab development is the computer-aided system of thermogasdynamic research and analysis “ASTRA”. The features of gas turbine engine transient modes simulator are described. The principal difference between the simulators of transient and stationary modes of gas turbine engines is that the energy balance of the compressor and turbine becomes not applicable. The computer-aided system of virtual gas turbine engine testing was created using the developed transient modes simulator. This system solves the tasks of operational (throttling, speed, climatic, altitude characteristics calculation, analysis of transient dynamics and selection of optimal control laws. Besides, the system of virtual gas turbine engine testing is a clear demonstration of gas turbine engine working process and the regularities of engine elements collaboration. The interface of the system of virtual gas turbine engine testing is described in the article and some screenshots of the interface elements are provided. The developed system of virtual gas turbine engine testing provides means for reducing the laboriousness of gas turbine engines testing. Besides, the implementation of this system in the learning process allows the diversification of lab works and therefore improve the quality of training.

  17. Standardized evaluation of algorithms for computer-aided diagnosis of dementia based on structural MRI

    DEFF Research Database (Denmark)

    Bron, Esther E.; Smits, Marion; van der Flier, Wiesje M.

    2015-01-01

    algorithms based on a clinically representative multi-center data set. Using clinical practice as the starting point, the goal was to reproduce the clinical diagnosis. Therefore, we evaluated algorithms for multi-class classification of three diagnostic groups: patients with probable Alzheimer's disease...... of aging). The best performing algorithm yielded an accuracy of 63.0% and an area under the receiver-operating-characteristic curve (AUC) of 78.8%. In general, the best performances were achieved using feature extraction based on voxel-based morphometry or a combination of features that included volume......Abstract Algorithms for computer-aided diagnosis of dementia based on structural MRI have demonstrated high performance in the literature, but are difficult to compare as different data sets and methodology were used for evaluation. In addition, it is unclear how the algorithms would perform...

  18. A Robust and Fast System for CTC Computer-Aided Detection of Colorectal Lesions

    Directory of Open Access Journals (Sweden)

    Gareth Beddoe

    2010-01-01

    Full Text Available We present a complete, end-to-end computer-aided detection (CAD system for identifying lesions in the colon, imaged with computed tomography (CT. This system includes facilities for colon segmentation, candidate generation, feature analysis, and classification. The algorithms have been designed to offer robust performance to variation in image data and patient preparation. By utilizing efficient 2D and 3D processing, software optimizations, multi-threading, feature selection, and an optimized cascade classifier, the CAD system quickly determines a set of detection marks. The colon CAD system has been validated on the largest set of data to date, and demonstrates excellent performance, in terms of its high sensitivity, low false positive rate, and computational efficiency.

  19. Computer Aided Diagnosis for Confocal Laser Endomicroscopy in Advanced Colorectal Adenocarcinoma

    DEFF Research Database (Denmark)

    Ştefănescu, Daniela; Streba, Costin; Cârţână, Elena Tatiana

    2016-01-01

    functions, a module for fractal analysis, grey-level co-occurrence matrix (GLCM) computation module, and a feature identification module based on the Marching Squares and linear interpolation methods. A two-layer neural network was trained to automatically interpret the imaging data and diagnose...... the pathological samples based on the fractal dimension and the characteristic features of the biological tissues. RESULTS: Normal colon mucosa is characterized by regular polyhedral crypt structures whereas malignant colon mucosa is characterized by irregular and interrupted crypts, which can be diagnosed by CAD.......14, validation: 17.42, testing: 15.48. The diagnosis accuracy error was 15.5%. CONCLUSIONS: Computed aided diagnosis via fractal analysis of glandular structures can complement the traditional histological and minimally invasive imaging methods. A larger dataset from colorectal and other pathologies should...

  20. Computer Aided Diagnosis for Confocal Laser Endomicroscopy in Advanced Colorectal Adenocarcinoma.

    Directory of Open Access Journals (Sweden)

    Daniela Ştefănescu

    Full Text Available Confocal laser endomicroscopy (CLE is becoming a popular method for optical biopsy of digestive mucosa for both diagnostic and therapeutic procedures. Computer aided diagnosis of CLE images, using image processing and fractal analysis can be used to quantify the histological structures in the CLE generated images. The aim of this study is to develop an automatic diagnosis algorithm of colorectal cancer (CRC, based on fractal analysis and neural network modeling of the CLE-generated colon mucosa images.We retrospectively analyzed a series of 1035 artifact-free endomicroscopy images, obtained during CLE examinations from normal mucosa (356 images and tumor regions (679 images. The images were processed using a computer aided diagnosis (CAD medical imaging system in order to obtain an automatic diagnosis. The CAD application includes image reading and processing functions, a module for fractal analysis, grey-level co-occurrence matrix (GLCM computation module, and a feature identification module based on the Marching Squares and linear interpolation methods. A two-layer neural network was trained to automatically interpret the imaging data and diagnose the pathological samples based on the fractal dimension and the characteristic features of the biological tissues.Normal colon mucosa is characterized by regular polyhedral crypt structures whereas malignant colon mucosa is characterized by irregular and interrupted crypts, which can be diagnosed by CAD. For this purpose, seven geometric parameters were defined for each image: fractal dimension, lacunarity, contrast correlation, energy, homogeneity, and feature number. Of the seven parameters only contrast, homogeneity and feature number were significantly different between normal and cancer samples. Next, a two-layer feed forward neural network was used to train and automatically diagnose the malignant samples, based on the seven parameters tested. The neural network operations were cross

  1. Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing.

    Science.gov (United States)

    Oh, Ji-Hyeon

    2018-12-01

    With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

  2. Costs incurred by applying computer-aided design/computer-aided manufacturing techniques for the reconstruction of maxillofacial defects.

    Science.gov (United States)

    Rustemeyer, Jan; Melenberg, Alex; Sari-Rieger, Aynur

    2014-12-01

    This study aims to evaluate the additional costs incurred by using a computer-aided design/computer-aided manufacturing (CAD/CAM) technique for reconstructing maxillofacial defects by analyzing typical cases. The medical charts of 11 consecutive patients who were subjected to the CAD/CAM technique were considered, and invoices from the companies providing the CAD/CAM devices were reviewed for every case. The number of devices used was significantly correlated with cost (r = 0.880; p costs were found between cases in which prebent reconstruction plates were used (€3346.00 ± €29.00) and cases in which they were not (€2534.22 ± €264.48; p costs of two, three and four devices, even when ignoring the cost of reconstruction plates. Additional fees provided by statutory health insurance covered a mean of 171.5% ± 25.6% of the cost of the CAD/CAM devices. Since the additional fees provide financial compensation, we believe that the CAD/CAM technique is suited for wide application and not restricted to complex cases. Where additional fees/funds are not available, the CAD/CAM technique might be unprofitable, so the decision whether or not to use it remains a case-to-case decision with respect to cost versus benefit. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology.

    Science.gov (United States)

    Arafa, Khalid A O

    2018-01-01

    To assess the level of evidence that supports the quality of fit for removable partial denture (RPD) fabricated by computer-aided designing/computer aided manufacturing (CAD/CAM) and rapid prototyping (RP) technology. Methods: An electronic search was performed in Google Scholar, PubMed, and Cochrane library search engines, using Boolean operators. All articles published in English and published in the period from 1950 until April 2017 were eligible to be included in this review. The total number of articles contained the search terms in any part of the article (including titles, abstracts, or article texts) were screened, which resulted in 214 articles. After exclusion of irrelevant and duplicated articles, 12 papers were included in this systematic review.  Results: All the included studies were case reports, except one study, which was a case series that recruited 10 study participants. The visual and tactile examination in the cast or clinically in the patient's mouth was the most-used method for assessment of the fit of RPDs. From all included studies, only one has assessed the internal fit between RPDs and oral tissues using silicone registration material. The vast majority of included studies found that the fit of RPDs ranged from satisfactory to excellent fit. Conclusion: Despite the lack of clinical trials that provide strong evidence, the available evidence supported the claim of good fit of RPDs fabricated by new technologies using CAD/CAM.

  4. 13th International Conference on Computer Aided Engineering

    CERN Document Server

    Pietrusiak, Damian

    2017-01-01

    These proceedings of the 13th International Conference on Computer Aided Engineering present selected papers from the event, which was held in Polanica Zdrój, Poland, from June 22 to 25, 2016. The contributions are organized according to thematic sections on the design and manufacture of machines and technical systems; durability prediction; repairs and retrofitting of power equipment; strength and thermodynamic analyses for power equipment; design and calculation of various types of load-carrying structures; numerical methods for dimensioning materials handling; and long-distance transport equipment. The conference and its proceedings offer a major interdisciplinary forum for researchers and engineers to present the most innovative studies and advances in this dynamic field.

  5. Application of computer aided tolerance analysis in product design

    International Nuclear Information System (INIS)

    Du Hua

    2009-01-01

    This paper introduces the shortage of the traditional tolerance design method and the strong point of the computer aided tolerancing (CAT) method,compares the shortage and the strong point among the three tolerance analysis methods, which are Worst Case Analysis, Statistical Analysis and Monte-Carlo Simulation Analysis, and offers the basic courses and correlative details for CAT. As the study objects, the reactor pressure vessel, the core barrel, the hold-down barrel and the support plate are used to upbuild the tolerance simulation model, based on their 3D design models. Then the tolerance simulation analysis has been conducted and the scheme of the tolerance distribution is optimized based on the analysis results. (authors)

  6. Computer aided instruction in the nuclear training classroom

    International Nuclear Information System (INIS)

    McFarlane, A.F.

    1983-01-01

    The objectives formulated for introducing computer aided instruction into the nuclear training programme are discussed and the process of comparative evaluation which was followed to arrive at a preferred system is described. Three points must be remembered. First it is unlikely that specialized training will benefit from any cost reduction since the total manpower invested can seldom be applied over enough students to represent an overall cost saving when compared with conventional classroom methods. Second it is unnecessary to present on a video screen material which would be better left in its original printed textbook or manual. Thirdly care must be taken not to assume too much or too little prior knowledge in the student. In nuclear training, concentrated information transfer is required in a short period of time. Carefully planned and executed computer assisted instruction can improve teaching effectiveness and provide a welcome alternative to conventional classroom instruction. (U.K.)

  7. Computer-aided resource planning and scheduling for radiological services

    Science.gov (United States)

    Garcia, Hong-Mei C.; Yun, David Y.; Ge, Yiqun; Khan, Javed I.

    1996-05-01

    There exists tremendous opportunity in hospital-wide resource optimization based on system integration. This paper defines the resource planning and scheduling requirements integral to PACS, RIS and HIS integration. An multi-site case study is conducted to define the requirements. A well-tested planning and scheduling methodology, called Constrained Resource Planning model, has been applied to the chosen problem of radiological service optimization. This investigation focuses on resource optimization issues for minimizing the turnaround time to increase clinical efficiency and customer satisfaction, particularly in cases where the scheduling of multiple exams are required for a patient. How best to combine the information system efficiency and human intelligence in improving radiological services is described. Finally, an architecture for interfacing a computer-aided resource planning and scheduling tool with the existing PACS, HIS and RIS implementation is presented.

  8. Micro computer aided beam transport for the SF cyclotron

    International Nuclear Information System (INIS)

    Honma, Toshihiro; Yamazaki, Tsutomu.

    1984-01-01

    An improvement of the beam transport system for the SF cyclotron is described. The system was designed to handle on-line alignment of the beam extracted from the SF cyclotron onto the optical axis of the transport line. It also enables to measure the beam emittance. The measurement of the emittance parameters is in particular necessary to calculate the beam optics. The calculation has been modified to become easy to handle. With the help of the computer-aided on-line beam profile measurement system, the operation of the beam transport system is very subservient to shorten the beam-tuning time and to improve the beam-transmission efficiency and the quality. (author)

  9. Computer aided design of nickel-base superalloys

    International Nuclear Information System (INIS)

    Lawrence, P.J.

    1988-01-01

    This paper describes a computer aided design process for Ni-base superalloys developed and employed at ASEA Brown Boveri. The technique involves a series of modules each of which predicts a particular property of a hypothetical new composition. In the first stage of the development of this design techniques modules were produced to predict phase stability, using PHACOMP, and high temperature creep strength and hot corrosion resistance, using multiple linear regression equations derived from the data in the literature. Alloys designed using these technique are also discussed and, in particular, shortcomings of the design process are highlighted. This information was then used to produce a revamped design methodology involving extra modules, including prediction of an alloy's gamma-prime content. (orig.)

  10. Computer-aided assessment in statistics: the CAMPUS project

    Directory of Open Access Journals (Sweden)

    Neville Hunt

    1998-12-01

    Full Text Available The relentless drive for 'efficiency' in higher education, and the consequent increase in workloads, has given university teachers a compelling incentive to investigate alternative forms of assessment. Some forms of assessment with a clear educational value can no longer be entertained because of the burden placed on the teacher. An added concern is plagiarism, which anecdotal evidence would suggest is on the increase yet which is difficult to detect in large modules with more than one assessor. While computer-aided assessment (CAA has an enthusiastic following, it is not clear to many teachers that it either reduces workloads or reduces the risk of cheating. In an ideal world, most teachers would prefer to give individual attention and personal feedback to each student when marking their work. In this sense CAA must be seen as second best and will therefore be used only if it is seen to offer significant benefits in terms of reduced workloads or increased validity.

  11. Computer Aided Automatic Control - CAAC artificial intelligence block

    Energy Technology Data Exchange (ETDEWEB)

    Balate, J.; Chramcov, B.; Princ, M. [Brno Univ. of Technology (Czech Republic). Faculty of Technology in Zlin

    2000-07-01

    The aim of the plan to build up the system CAAC - Computer Aided Automatic Control is to create modular setup of partial computing programs including theory of automatic control, algorithms of programs for processing signals and programs of control algorithms. To approach its informative contents to students and professional public the CAAC system utilizes Internet services http in the form of WWW pages. The CAAC system is being processed at the Institute of Automation and Control Technique of the Faculty of Technology in Zlin of the Brno University of Technology and is determined particularly for pedagogic purposes. Recently also the methods of artificial intelligence have been included to the open CAAC system and that is comprised in this article. (orig.)

  12. Use of computer-aided-engineering (CAE) for configuration management

    International Nuclear Information System (INIS)

    Bellon, M.

    1989-01-01

    For nearly 25 years, Electricite de France (EDF) has been designing and building nuclear power plants, and now has more than 50 in operation. During this period, EDF has faced problems common to all designers and operators. The author discusses two major aspects which must be dealt with to design a power plant: installation design and operational description. In both cases, the designer has to ensure that all parameters conform to the design requirements and that all documents are consistent with each other. For the operational description, the most important part of the job is to check and maintain consistency between the various documents: P and ID's, functional diagrams, cable networks, procedures, data management and also installation drawings. The author discusses how EDF has chosen two computer aided design softwares---PDMS and PHENIX---and has built a powerful engineering system around them

  13. Computer- Aided Design in Power Engineering Application of Software Tools

    CERN Document Server

    Stojkovic, Zlatan

    2012-01-01

    This textbooks demonstrates the application of software tools in solving a series of problems from the field of designing power system structures and systems. It contains four chapters: The first chapter leads the reader through all the phases necessary in the procedures of computer aided modeling and simulation. It guides through the complex problems presenting on the basis of eleven original examples. The second chapter presents  application of software tools in power system calculations of power systems equipment design. Several design example calculations are carried out using engineering standards like MATLAB, EMTP/ATP, Excel & Access, AutoCAD and Simulink. The third chapters focuses on the graphical documentation using a collection of software tools (AutoCAD, EPLAN, SIMARIS SIVACON, SIMARIS DESIGN) which enable the complete automation of the development of graphical documentation of a power systems. In the fourth chapter, the application of software tools in the project management in power systems ...

  14. Computer-Aided Sustainable Process Synthesis-Design and Analysis

    DEFF Research Database (Denmark)

    Kumar Tula, Anjan

    -groups is that, the performance of the entire process can be evaluated from the contributions of the individual process-groups towards the selected flowsheet property (for example, energy consumed). The developed flowsheet property models include energy consumption, carbon footprint, product recovery, product......Process synthesis involves the investigation of chemical reactions needed to produce the desired product, selection of the separation techniques needed for downstream processing, as well as taking decisions on sequencing the involved separation operations. For an effective, efficient and flexible...... focuses on the development and application of a computer-aided framework for sustainable synthesis-design and analysis of process flowsheets by generating feasible alternatives covering the entire search space and includes analysis tools for sustainability, LCA and economics. The synthesis method is based...

  15. [Veneer computer aided design based on reverse engineering technology].

    Science.gov (United States)

    Liu, Ming-li; Chen, Xiao-dong; Wang, Yong

    2012-03-01

    To explore the computer aided design (CAD) method of veneer restoration, and to assess if the solution can help prosthesis meet morphology esthetics standard. A volunteer's upper right central incisor needed to be restored with veneer. Super hard stone models of patient's dentition (before and after tooth preparation) were scanned with the three-dimensional laser scanner. The veneer margin was designed as butt-to-butt type. The veneer was constructed using reverse engineering (RE) software. The technique guideline of veneers CAD was explore based on RE software, and the veneers was smooth, continuous and symmetrical, which met esthetics construction needs. It was a feasible method to reconstruct veneer restoration based on RE technology.

  16. Computer-Aided Numerical Inversion of Laplace Transform

    Directory of Open Access Journals (Sweden)

    Umesh Kumar

    2000-01-01

    Full Text Available This paper explores the technique for the computer aided numerical inversion of Laplace transform. The inversion technique is based on the properties of a family of three parameter exponential probability density functions. The only limitation in the technique is the word length of the computer being used. The Laplace transform has been used extensively in the frequency domain solution of linear, lumped time invariant networks but its application to the time domain has been limited, mainly because of the difficulty in finding the necessary poles and residues. The numerical inversion technique mentioned above does away with the poles and residues but uses precomputed numbers to find the time response. This technique is applicable to the solution of partially differentiable equations and certain classes of linear systems with time varying components.

  17. PACS-Based Computer-Aided Detection and Diagnosis

    Science.gov (United States)

    Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge

    The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.

  18. [A computer-aided image diagnosis and study system].

    Science.gov (United States)

    Li, Zhangyong; Xie, Zhengxiang

    2004-08-01

    The revolution in information processing, particularly the digitizing of medicine, has changed the medical study, work and management. This paper reports a method to design a system for computer-aided image diagnosis and study. Combined with some good idea of graph-text system and picture archives communicate system (PACS), the system was realized and used for "prescription through computer", "managing images" and "reading images under computer and helping the diagnosis". Also typical examples were constructed in a database and used to teach the beginners. The system was developed by the visual developing tools based on object oriented programming (OOP) and was carried into operation on the Windows 9X platform. The system possesses friendly man-machine interface.

  19. Computer-Aided Grading of Lymphangioleiomyomatosis (LAM) using HRCT

    Science.gov (United States)

    Yao, Jianhua; Avila, Nilo; Dwyer, Andrew; Taveira-DaSilva, Angelo M.; Hathaway, Olanda M.; Moss, Joel

    2010-01-01

    Lymphangioleiomyomatosis (LAM) is a multisystem disorder associated with proliferation of smooth muscle-like cells, which leads to destruction of lung parenchyma. Subjective grading of LAM on HRCT is imprecise and can be arduous especially in cases with severe involvement. We propose a computer-aided evaluation system that grades LAM involvement based on analysis of lung texture patterns. A committee of support vector machines is employed for classification. The system was tested on 36 patients. The computer grade demonstrates good correlation with subjective radiologist grade (R=0.91, p<0.0001) and pulmonary functional tests (R=0.85, p<0.0001). The grade also provides precise progression assessment of disease over time. PMID:21625320

  20. Computer aided analysis, simulation and optimisation of thermal sterilisation processes.

    Science.gov (United States)

    Narayanan, C M; Banerjee, Arindam

    2013-04-01

    Although thermal sterilisation is a widely employed industrial process, little work is reported in the available literature including patents on the mathematical analysis and simulation of these processes. In the present work, software packages have been developed for computer aided optimum design of thermal sterilisation processes. Systems involving steam sparging, jacketed heating/cooling, helical coils submerged in agitated vessels and systems that employ external heat exchangers (double pipe, shell and tube and plate exchangers) have been considered. Both batch and continuous operations have been analysed and simulated. The dependence of del factor on system / operating parameters such as mass or volume of substrate to be sterilised per batch, speed of agitation, helix diameter, substrate to steam ratio, rate of substrate circulation through heat exchanger and that through holding tube have been analysed separately for each mode of sterilisation. Axial dispersion in the holding tube has also been adequately accounted for through an appropriately defined axial dispersion coefficient. The effect of exchanger characteristics/specifications on the system performance has also been analysed. The multiparameter computer aided design (CAD) software packages prepared are thus highly versatile in nature and they permit to make the most optimum choice of operating variables for the processes selected. The computed results have been compared with extensive data collected from a number of industries (distilleries, food processing and pharmaceutical industries) and pilot plants and satisfactory agreement has been observed between the two, thereby ascertaining the accuracy of the CAD softwares developed. No simplifying assumptions have been made during the analysis and the design of associated heating / cooling equipment has been performed utilising the most updated design correlations and computer softwares.

  1. Computer-aided analysis of cutting processes for brittle materials

    Science.gov (United States)

    Ogorodnikov, A. I.; Tikhonov, I. N.

    2017-12-01

    This paper is focused on 3D computer simulation of cutting processes for brittle materials and silicon wafers. Computer-aided analysis of wafer scribing and dicing is carried out with the use of the ANSYS CAE (computer-aided engineering) software, and a parametric model of the processes is created by means of the internal ANSYS APDL programming language. Different types of tool tip geometry are analyzed to obtain internal stresses, such as a four-sided pyramid with an included angle of 120° and a tool inclination angle to the normal axis of 15°. The quality of the workpieces after cutting is studied by optical microscopy to verify the FE (finite-element) model. The disruption of the material structure during scribing occurs near the scratch and propagates into the wafer or over its surface at a short range. The deformation area along the scratch looks like a ragged band, but the stress width is rather low. The theory of cutting brittle semiconductor and optical materials is developed on the basis of the advanced theory of metal turning. The fall of stress intensity along the normal on the way from the tip point to the scribe line can be predicted using the developed theory and with the verified FE model. The crystal quality and dimensions of defects are determined by the mechanics of scratching, which depends on the shape of the diamond tip, the scratching direction, the velocity of the cutting tool and applied force loads. The disunity is a rate-sensitive process, and it depends on the cutting thickness. The application of numerical techniques, such as FE analysis, to cutting problems enhances understanding and promotes the further development of existing machining technologies.

  2. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    Science.gov (United States)

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  3. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur; Yaroshenko, Andre; Velroyen, Astrid

    2015-01-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering...... properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists...... of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually...

  4. History and evolution of the pharmacophore concept in computer-aided drug design.

    Science.gov (United States)

    Güner, Osman F

    2002-12-01

    With computer-aided drug design established as an integral part of the lead discovery and optimization process, pharmacophores have become a focal point for conceptualizing and understanding receptor-ligand interactions. In the structure-based design process, pharmacophores can be used to align molecules based on the three-dimensional arrangement of chemical features or to develop predictive models (e.g., 3D-QSAR) that correlate with the experimental activities of a given training set. Pharmacophores can be also used as search queries for retrieving potential leads from structural databases, for designing molecules with specific desired attributes, or as fingerprints for assessing similarity and diversity of molecules. This review article presents a historical perspective on the evolution and use of the pharmacophore concept in the pharmaceutical, biotechnology, and fragrances industry with published examples of how the technology has contributed and advanced the field.

  5. A computer-aided diagnostic and troubleshooting system for fuel cell power plants

    International Nuclear Information System (INIS)

    Unkle, C.R.

    1990-10-01

    This Interactive Computer-Aided Troubleshooting System (ICATS) was designed as a troubleshooting aid for the Tokyo Electric Power Company (TEPCO) 11-megawatt dc Module (DCM). ICATS represents an integration of the System Testability and Maintenance Program (STAMP reg-sign) and the Portable Interactive Troubleshooter (POINTER trademark) software packages developed by ARINC Research Corporation. ICATS was designed to aid in the fault isolation of shutdown conditions that may occur in the DCM during on-load operations and start-up, and hold conditions that may occur during start-up. ICATS may also be used to help fault-isolate a return-to-standby condition occurring from on-load operation of the DCM. This report describes the development of ICATS and the ICATS functional design. The unique features of STAMP and POINTER, which allow for diagnostic aids to be designed for systems not yet built and operating, are also described. 10 refs., 21 figs., 6 tabs

  6. Computer Aided Teaching in Photogrammetry, Remote Sensing, and Geomatics - A Status Review

    Science.gov (United States)

    Vyas, A.; Koenig, G.

    2014-04-01

    Education and training play vital role in the utilization of the technology. Shared and coordinated knowledge that geospatial technology and GIS deliver provides a deeper understanding of our present and will also help to better understand our future development. But it is not enough to explain new technological developments during congresses or workshops; it is also necessary to promote these new ideas and to distribute the knowledge by applying new learning strategies. This paper will review the status of computer aided teaching advances during the last decade, with a particular emphasis on photogrammetry, remote sensing, and geomatics. Some best practise examples will be presented featuring prominently recent Massive Open Online Courses (MOOCs) related to our fields. The consideration of mainly free online learning resources will include a commentary on quality and perceived effectiveness.

  7. Molecular structure descriptors in the computer-aided design of biologically active compounds

    International Nuclear Information System (INIS)

    Raevsky, Oleg A

    1999-01-01

    The current state of description of molecular structure in computer-aided molecular design of biologically active compounds by means of descriptors is analysed. The information contents of descriptors increases in the following sequence: element-level descriptors-structural formulae descriptors-electronic structure descriptors-molecular shape descriptors-intermolecular interaction descriptors. Each subsequent class of descriptors normally covers information contained in the previous-level ones. It is emphasised that it is practically impossible to describe all the features of a molecular structure in terms of any single class of descriptors. It is recommended to optimise the number of descriptors used by means of appropriate statistical procedures and characteristics of structure-property models based on these descriptors. The bibliography includes 371 references.

  8. Software Infrastructure for Computer-aided Drug Discovery and Development, a Practical Example with Guidelines.

    Science.gov (United States)

    Moretti, Loris; Sartori, Luca

    2016-09-01

    In the field of Computer-Aided Drug Discovery and Development (CADDD) the proper software infrastructure is essential for everyday investigations. The creation of such an environment should be carefully planned and implemented with certain features in order to be productive and efficient. Here we describe a solution to integrate standard computational services into a functional unit that empowers modelling applications for drug discovery. This system allows users with various level of expertise to run in silico experiments automatically and without the burden of file formatting for different software, managing the actual computation, keeping track of the activities and graphical rendering of the structural outcomes. To showcase the potential of this approach, performances of five different docking programs on an Hiv-1 protease test set are presented. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Computer-Aided Grading of Gliomas Combining Automatic Segmentation and Radiomics

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2018-01-01

    Full Text Available Gliomas are the most common primary brain tumors, and the objective grading is of great importance for treatment. This paper presents an automatic computer-aided diagnosis of gliomas that combines automatic segmentation and radiomics, which can improve the diagnostic ability. The MRI data containing 220 high-grade gliomas and 54 low-grade gliomas are used to evaluate our system. A multiscale 3D convolutional neural network is trained to segment whole tumor regions. A wide range of radiomic features including first-order features, shape features, and texture features is extracted. By using support vector machines with recursive feature elimination for feature selection, a CAD system that has an extreme gradient boosting classifier with a 5-fold cross-validation is constructed for the grading of gliomas. Our CAD system is highly effective for the grading of gliomas with an accuracy of 91.27%, a weighted macroprecision of 91.27%, a weighted macrorecall of 91.27%, and a weighted macro-F1 score of 90.64%. This demonstrates that the proposed CAD system can assist radiologists for high accurate grading of gliomas and has the potential for clinical applications.

  10. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration.

    Science.gov (United States)

    Juntavee, Niwut; Sirisathit, Issarawas

    2018-01-01

    This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel-chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system ( p marginal gap than the conventional cast metal restoration ( p marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration.

  11. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system

    Science.gov (United States)

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T=62.6±65.2 μm; MC=60.4±38.4 μm; PMC=58.1±38.0 μm, and RI=89.8±62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T=71.5%, RI=49.2%, MC=69.6%, and PMC=71.2%. The percentages of horizontal overextension were T=8.5%, RI=0%, MC=0.8%, and PMC=3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  12. Computer-aided classification of breast masses using contrast-enhanced digital mammograms

    Science.gov (United States)

    Danala, Gopichandh; Aghaei, Faranak; Heidari, Morteza; Wu, Teresa; Patel, Bhavika; Zheng, Bin

    2018-02-01

    By taking advantages of both mammography and breast MRI, contrast-enhanced digital mammography (CEDM) has emerged as a new promising imaging modality to improve efficacy of breast cancer screening and diagnosis. The primary objective of study is to develop and evaluate a new computer-aided detection and diagnosis (CAD) scheme of CEDM images to classify between malignant and benign breast masses. A CEDM dataset consisting of 111 patients (33 benign and 78 malignant) was retrospectively assembled. Each case includes two types of images namely, low-energy (LE) and dual-energy subtracted (DES) images. First, CAD scheme applied a hybrid segmentation method to automatically segment masses depicting on LE and DES images separately. Optimal segmentation results from DES images were also mapped to LE images and vice versa. Next, a set of 109 quantitative image features related to mass shape and density heterogeneity was initially computed. Last, four multilayer perceptron-based machine learning classifiers integrated with correlationbased feature subset evaluator and leave-one-case-out cross-validation method was built to classify mass regions depicting on LE and DES images, respectively. Initially, when CAD scheme was applied to original segmentation of DES and LE images, the areas under ROC curves were 0.7585+/-0.0526 and 0.7534+/-0.0470, respectively. After optimal segmentation mapping from DES to LE images, AUC value of CAD scheme significantly increased to 0.8477+/-0.0376 (pbreast tissue on lesions, segmentation accuracy was significantly improved as compared to regular mammograms, the study demonstrated that computer-aided classification of breast masses using CEDM images yielded higher performance.

  13. Computer-aided sperm analysis: a useful tool to evaluate patient's response to varicocelectomy.

    Science.gov (United States)

    Ariagno, Julia I; Mendeluk, Gabriela R; Furlan, María J; Sardi, M; Chenlo, P; Curi, Susana M; Pugliese, Mercedes N; Repetto, Herberto E; Cohen, Mariano

    2017-01-01

    Preoperative and postoperative sperm parameter values from infertile men with varicocele were analyzed by computer-aided sperm analysis (CASA) to assess if sperm characteristics improved after varicocelectomy. Semen samples of men with proven fertility (n = 38) and men with varicocele-related infertility (n = 61) were also analyzed. Conventional semen analysis was performed according to WHO (2010) criteria and a CASA system was employed to assess kinetic parameters and sperm concentration. Seminal parameters values in the fertile group were very far above from those of the patients, either before or after surgery. No significant improvement in the percentage normal sperm morphology (P = 0.10), sperm concentration (P = 0.52), total sperm count (P = 0.76), subjective motility (%) (P = 0.97) nor kinematics (P = 0.30) was observed after varicocelectomy when all groups were compared. Neither was significant improvement found in percentage normal sperm morphology (P = 0.91), sperm concentration (P = 0.10), total sperm count (P = 0.89) or percentage motility (P = 0.77) after varicocelectomy in paired comparisons of preoperative and postoperative data. Analysis of paired samples revealed that the total sperm count (P = 0.01) and most sperm kinetic parameters: curvilinear velocity (P = 0.002), straight-line velocity (P = 0.0004), average path velocity (P = 0.0005), linearity (P = 0.02), and wobble (P = 0.006) improved after surgery. CASA offers the potential for accurate quantitative assessment of each patient's response to varicocelectomy.

  14. Geometric and computer-aided spline hob modeling

    Science.gov (United States)

    Brailov, I. G.; Myasoedova, T. M.; Panchuk, K. L.; Krysova, I. V.; Rogoza, YU A.

    2018-03-01

    The paper considers acquiring the spline hob geometric model. The objective of the research is the development of a mathematical model of spline hob for spline shaft machining. The structure of the spline hob is described taking into consideration the motion in parameters of the machine tool system of cutting edge positioning and orientation. Computer-aided study is performed with the use of CAD and on the basis of 3D modeling methods. Vector representation of cutting edge geometry is accepted as the principal method of spline hob mathematical model development. The paper defines the correlations described by parametric vector functions representing helical cutting edges designed for spline shaft machining with consideration for helical movement in two dimensions. An application for acquiring the 3D model of spline hob is developed on the basis of AutoLISP for AutoCAD environment. The application presents the opportunity for the use of the acquired model for milling process imitation. An example of evaluation, analytical representation and computer modeling of the proposed geometrical model is reviewed. In the mentioned example, a calculation of key spline hob parameters assuring the capability of hobbing a spline shaft of standard design is performed. The polygonal and solid spline hob 3D models are acquired by the use of imitational computer modeling.

  15. Computer-Aided Experiment Planning toward Causal Discovery in Neuroscience.

    Science.gov (United States)

    Matiasz, Nicholas J; Wood, Justin; Wang, Wei; Silva, Alcino J; Hsu, William

    2017-01-01

    Computers help neuroscientists to analyze experimental results by automating the application of statistics; however, computer-aided experiment planning is far less common, due to a lack of similar quantitative formalisms for systematically assessing evidence and uncertainty. While ontologies and other Semantic Web resources help neuroscientists to assimilate required domain knowledge, experiment planning requires not only ontological but also epistemological (e.g., methodological) information regarding how knowledge was obtained. Here, we outline how epistemological principles and graphical representations of causality can be used to formalize experiment planning toward causal discovery. We outline two complementary approaches to experiment planning: one that quantifies evidence per the principles of convergence and consistency, and another that quantifies uncertainty using logical representations of constraints on causal structure. These approaches operationalize experiment planning as the search for an experiment that either maximizes evidence or minimizes uncertainty. Despite work in laboratory automation, humans must still plan experiments and will likely continue to do so for some time. There is thus a great need for experiment-planning frameworks that are not only amenable to machine computation but also useful as aids in human reasoning.

  16. Present state of computer-aided diagnosis (CAD) development

    International Nuclear Information System (INIS)

    Fujita, Hiroshi

    2007-01-01

    Topics of computer-aided detection (CAD) are reviewed. Commercially available, Food and Drug Administration (FDA)-approved CAD systems are for fields of breast cancer (mammography), chest (flat X-ray and CT imaging) and colon (polyp detection). In Japan, only mammography CAD is approved. Efficacy of CAD is controversial, for which reliable database is important, and its construction is under development in various medical fields. Digitalized image is now popularized, which conceivably leads to improve the cost-effectiveness of diagnosis with CAD. For incentive, approval for health insurance would be the case as seen in the increased CAD sale by R2 Technology Co., and MHLW actually assists facilities to introduce the reading-aid system of mammography by sharing a half of its cost. There are 2 big projects for CAD study supported by MECSST, which the author concerns. One is the development of diagnostic aid for the multi-dimensional medical images where the multi-organ, multi-disease CAD system is considered. The other involves the CAD in brain MRI, in breast US and in eyeground picture. It is not in so far future for patients and doctors to fully enjoy the benefit of CAD. (R.T.)

  17. Computer-aided safety systems of industrial high energy objects

    International Nuclear Information System (INIS)

    Topolsky, N.G.; Gordeev, S.G.

    1995-01-01

    Modern objects of fuel and energy, chemical industries are characterized by high power consumption; by presence of large quantities of combustible and explosive substances used in technological processes; by advanced communications of submission systems of initial liquid and gasiform reagents, lubricants and coolants, the products of processing, and wastes of production; by advanced ventilation and pneumatic transport; and by complex control systems of energy, material and information flows. Such objects have advanced infrastructures, including a significant quantity of engineering buildings intended for storage, transportation, and processing of combustible liquids, gasiform fuels and materials, and firm materials. Examples of similar objects are nuclear and thermal power stations, chemical plants, machine-building factories, iron and steel industry enterprises, etc. Many tasks and functions characterizing the problem of fire safety of these objects can be accomplished only upon the development of special Computer-Aided Fire Safety Systems (CAFSS). The CAFSS for these objects are intended to reduce the hazard of disastrous accidents both causing fires and caused by them. The tasks of fire prevention and rescue work of large-scale industrial objects are analyzed within the bounds of the recommended conception. A functional structure of CAFSS with a list of the main subsystems forming a part of its composition has been proposed

  18. Computer-Aided Drug Discovery in Plant Pathology.

    Science.gov (United States)

    Shanmugam, Gnanendra; Jeon, Junhyun

    2017-12-01

    Control of plant diseases is largely dependent on use of agrochemicals. However, there are widening gaps between our knowledge on plant diseases gained from genetic/mechanistic studies and rapid translation of the knowledge into target-oriented development of effective agrochemicals. Here we propose that the time is ripe for computer-aided drug discovery/design (CADD) in molecular plant pathology. CADD has played a pivotal role in development of medically important molecules over the last three decades. Now, explosive increase in information on genome sequences and three dimensional structures of biological molecules, in combination with advances in computational and informational technologies, opens up exciting possibilities for application of CADD in discovery and development of agrochemicals. In this review, we outline two categories of the drug discovery strategies: structure- and ligand-based CADD, and relevant computational approaches that are being employed in modern drug discovery. In order to help readers to dive into CADD, we explain concepts of homology modelling, molecular docking, virtual screening, and de novo ligand design in structure-based CADD, and pharmacophore modelling, ligand-based virtual screening, quantitative structure activity relationship modelling and de novo ligand design for ligand-based CADD. We also provide the important resources available to carry out CADD. Finally, we present a case study showing how CADD approach can be implemented in reality for identification of potent chemical compounds against the important plant pathogens, Pseudomonas syringae and Colletotrichum gloeosporioides .

  19. The computer aided education and training system for accident management

    International Nuclear Information System (INIS)

    Yoneyama, Mitsuru; Masuda, Takahiro; Kubota, Ryuji; Fujiwara, Tadashi; Sakuma, Hitoshi

    2000-01-01

    Under severe accident conditions of a nuclear power plant, plant operators and technical support center (TSC) staffs will be under a amount of stress. Therefore, those individuals responsible for managing the plant should promote their understanding about the accident management and operations. Moreover, it is also important to train in ordinary times, so that they can carry out accident management operations effectively on severe accidents. Therefore, the education and training system which works on personal computers was developed by Japanese BWR group (Tokyo Electric Power Co.,Inc., Tohoku Electric Power Co. ,Inc., Chubu Electric Power Co. ,Inc., Hokuriku Electric Power Co.,Inc., Chugoku Electric Power Co.,Inc., Japan Atomic Power Co.,Inc.), and Hitachi, Ltd. The education and training system is composed of two systems. One is computer aided instruction (CAI) education system and the other is education and training system with a computer simulation. Both systems are designed to execute on MS-Windows(R) platform of personal computers. These systems provide plant operators and technical support center staffs with an effective education and training tool for accident management. TEPCO used the simulation system for the emergency exercise assuming the occurrence of hypothetical severe accident, and have performed an effective exercise in March, 2000. (author)

  20. Efficacy of computer-aided detection system for screening mammography

    International Nuclear Information System (INIS)

    Saito, Mioko; Ohnuki, Koji; Yamada, Takayuki; Saito, Haruo; Ishibashi, Tadashi; Ohuchi, Noriaki; Takahashi, Shoki

    2002-01-01

    A study was conducted to evaluate the efficacy of a computer-aided detection (CAD) system for screening mammography (MMG). Screening mammograms of 2,231 women aged over 50 yr were examined. Medio-lateral oblique (MLO) images were obtained, and two expert observers interpreted the mammograms by consensus. First, each mammogram was interpreted without the assistance of CAD, followed immediately by a re-evaluation of areas marked by the CAD system. Data were recorded to measure the effect of CAD on the recall rate, cancer detection rate and detection rate of masses, microcalcifications and other findings. The CAD system increased the recall rate from 2.3% to 2.6%. Six recalled cases were diagnosed as breast cancer pathologically, and CAD detected all of these lesions. Seven additional cases in which CAD detected abnormal findings had no malignancy. The detection rate of CAD for microcalcifications was high (95.0%). However, the detection rate for mass lesions and other findings was low (29.2% and 25.0% respectively). The false positivity rate was 0.13/film for microcalcifications, and 0.25/film for mass lesions. The efficacy of the CAD system for detecting microcalcifications on screening mammograms was confirmed. However, the low detection rate of mass lesions and relatively high rate of false positivity need to be further improved. (author)

  1. Computer-aided drug design at Boehringer Ingelheim

    Science.gov (United States)

    Muegge, Ingo; Bergner, Andreas; Kriegl, Jan M.

    2017-03-01

    Computer-Aided Drug Design (CADD) is an integral part of the drug discovery endeavor at Boehringer Ingelheim (BI). CADD contributes to the evaluation of new therapeutic concepts, identifies small molecule starting points for drug discovery, and develops strategies for optimizing hit and lead compounds. The CADD scientists at BI benefit from the global use and development of both software platforms and computational services. A number of computational techniques developed in-house have significantly changed the way early drug discovery is carried out at BI. In particular, virtual screening in vast chemical spaces, which can be accessed by combinatorial chemistry, has added a new option for the identification of hits in many projects. Recently, a new framework has been implemented allowing fast, interactive predictions of relevant on and off target endpoints and other optimization parameters. In addition to the introduction of this new framework at BI, CADD has been focusing on the enablement of medicinal chemists to independently perform an increasing amount of molecular modeling and design work. This is made possible through the deployment of MOE as a global modeling platform, allowing computational and medicinal chemists to freely share ideas and modeling results. Furthermore, a central communication layer called the computational chemistry framework provides broad access to predictive models and other computational services.

  2. Orthodontics: computer-aided diagnosis and treatment planning

    Science.gov (United States)

    Yi, Yaxing; Li, Zhongke; Wei, Suyuan; Deng, Fanglin; Yao, Sen

    2000-10-01

    The purpose of this article is to introduce the outline of our newly developed computer-aided 3D dental cast analyzing system with laser scanning, and its preliminary clinical applications. The system is composed of a scanning device and a personal computer as a scanning controller and post processor. The scanning device is composed of a laser beam emitter, two sets of linear CCD cameras and a table which is rotatable by two-degree-of-freedom. The rotating is controlled precisely by a personal computer. The dental cast is projected and scanned with a laser beam. Triangulation is applied to determine the location of each point. Generation of 3D graphics of the dental cast takes approximately 40 minutes. About 170,000 sets of X,Y,Z coordinates are store for one dental cast. Besides the conventional linear and angular measurements of the dental cast, we are also able to demonstrate the size of the top surface area of each molar. The advantage of this system is that it facilitates the otherwise complicated and time- consuming mock surgery necessary for treatment planning in orthognathic surgery.

  3. Development of computer-aided diagnosis systems in radiology

    International Nuclear Information System (INIS)

    Higashida, Yoshiharu; Arimura, Hidetaka; Kumazawa, Seiji; Morishita, Junji; Sakai, Shuji

    2006-01-01

    Computer-aided diagnosis (CAD) is a practice done by medical doctors based on computer image analysis as the second opinion, and CAD studies have been government-adopted projects. CAD is already on popular practice in the cancers of the breast by mammography, lung by flat plate and CT images, and large bowel by CT colonoscopy. This paper describes four examples of authors' actual CAD investigations. First, the temporal subtraction image analysis by CAD is for the detection of abnormality in the chest by radiographs taken at different times. Examples are shown in cases of interstitial pneumonia and lung cancer out of 34 patients with diffuse lung diseases. Second, development of CAD system is recorded for detection of aneurysm by the brain MR angiography (MRA). Third is the CAD detection of fascicles in cerebral white matters by the diffuse tensor MRI, which will help the surgery for brain tumors. Final is an automated patient recognition based on an image-matching technique using previous chest radiographs in the picture archiving and communication systems. This is on the radiograph giving biological fingerprints of the patients. CAD will be applied in a wider field of medicare not only in imaging technology. (T.I)

  4. Computer-aided diagnosis of colonic polyp by CT colonography

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki

    2007-01-01

    The outcome of National CT Colonography Trial, by American College of Radiology Imaging Network, 2006 (www.acrin.org/6664 protocol), possibly leads to the introduction of colorectal cancer screening in the US because CT colonography (CTCG) has been approved in the health insurance system. This paper describes the outline of computer-aided diagnosis (CAD) of colonic polyp by CTCG, its polyp detectability and future aspects. CTCG essentially derives from the virtual, abdominal 3D CT images and gives as many as about 500 images/patient, in the reading of which CAD support the expert. CAD technology in CTCG is said to have been essentially established in the first half of 2000s, which involves the cleansing of fecal tagging effect, extraction of the colonal wall from the image, detection of suspicious polyp, reduction of false-positive findings and displaying of the detected polyp. The detectability is thought to be at comparable level to expert's. The last displaying is done on the user-interface like Colon CAD Workstation. More efficient expert's reading with CAD, imaging without previous gut cleansing, detection of the flat lesion and further reduction of false-positive are the forthcoming tasks in clinical practice. Significance of CTCG is becoming in realization and its usage with CAD is thought to be more popular in Japan. (R.T.)

  5. Heuristic lipophilicity potential for computer-aided rational drug design

    Science.gov (United States)

    Du, Qishi; Arteca, Gustavo A.; Mezey, Paul G.

    1997-09-01

    In this contribution we suggest a heuristic molecular lipophilicitypotential (HMLP), which is a structure-based technique requiring noempirical indices of atomic lipophilicity. The input data used in thisapproach are molecular geometries and molecular surfaces. The HMLP is amodified electrostatic potential, combined with the averaged influences fromthe molecular environment. Quantum mechanics is used to calculate theelectron density function ρ(r) and the electrostatic potential V(r), andfrom this information a lipophilicity potential L(r) is generated. The HMLPis a unified lipophilicity and hydrophilicity potential. The interactions ofdipole and multipole moments, hydrogen bonds, and charged atoms in amolecule are included in the hydrophilic interactions in this model. TheHMLP is used to study hydrogen bonds and water-octanol partitioncoefficients in several examples. The calculated results show that the HMLPgives qualitatively and quantitatively correct, as well as chemicallyreasonable, results in cases where comparisons are available. Thesecomparisons indicate that the HMLP has advantages over the empiricallipophilicity potential in many aspects. The HMLP is a three-dimensional andeasily visualizable representation of molecular lipophilicity, suggested asa potential tool in computer-aided three-dimensional drug design.

  6. Computer-Aided Methodology for Syndromic Strabismus Diagnosis.

    Science.gov (United States)

    Sousa de Almeida, João Dallyson; Silva, Aristófanes Corrêa; Teixeira, Jorge Antonio Meireles; Paiva, Anselmo Cardoso; Gattass, Marcelo

    2015-08-01

    Strabismus is a pathology that affects approximately 4 % of the population, causing aesthetic problems reversible at any age and irreversible sensory alterations that modify the vision mechanism. The Hirschberg test is one type of examination for detecting this pathology. Computer-aided detection/diagnosis is being used with relative success to aid health professionals. Nevertheless, the routine use of high-tech devices for aiding ophthalmological diagnosis and therapy is not a reality within the subspecialty of strabismus. Thus, this work presents a methodology to aid in diagnosis of syndromic strabismus through digital imaging. Two hundred images belonging to 40 patients previously diagnosed by an specialist were tested. The method was demonstrated to be 88 % accurate in esotropias identification (ET), 100 % for exotropias (XT), 80.33 % for hypertropias (HT), and 83.33 % for hypotropias (HoT). The overall average error was 5.6Δ and 3.83Δ for horizontal and vertical deviations, respectively, against the measures presented by the specialist.

  7. Bone tissue engineering scaffolding: computer-aided scaffolding techniques.

    Science.gov (United States)

    Thavornyutikarn, Boonlom; Chantarapanich, Nattapon; Sitthiseripratip, Kriskrai; Thouas, George A; Chen, Qizhi

    Tissue engineering is essentially a technique for imitating nature. Natural tissues consist of three components: cells, signalling systems (e.g. growth factors) and extracellular matrix (ECM). The ECM forms a scaffold for its cells. Hence, the engineered tissue construct is an artificial scaffold populated with living cells and signalling molecules. A huge effort has been invested in bone tissue engineering, in which a highly porous scaffold plays a critical role in guiding bone and vascular tissue growth and regeneration in three dimensions. In the last two decades, numerous scaffolding techniques have been developed to fabricate highly interconnective, porous scaffolds for bone tissue engineering applications. This review provides an update on the progress of foaming technology of biomaterials, with a special attention being focused on computer-aided manufacturing (Andrade et al. 2002) techniques. This article starts with a brief introduction of tissue engineering (Bone tissue engineering and scaffolds) and scaffolding materials (Biomaterials used in bone tissue engineering). After a brief reviews on conventional scaffolding techniques (Conventional scaffolding techniques), a number of CAM techniques are reviewed in great detail. For each technique, the structure and mechanical integrity of fabricated scaffolds are discussed in detail. Finally, the advantaged and disadvantage of these techniques are compared (Comparison of scaffolding techniques) and summarised (Summary).

  8. ICADx: interpretable computer aided diagnosis of breast masses

    Science.gov (United States)

    Kim, Seong Tae; Lee, Hakmin; Kim, Hak Gu; Ro, Yong Man

    2018-02-01

    In this study, a novel computer aided diagnosis (CADx) framework is devised to investigate interpretability for classifying breast masses. Recently, a deep learning technology has been successfully applied to medical image analysis including CADx. Existing deep learning based CADx approaches, however, have a limitation in explaining the diagnostic decision. In real clinical practice, clinical decisions could be made with reasonable explanation. So current deep learning approaches in CADx are limited in real world deployment. In this paper, we investigate interpretability in CADx with the proposed interpretable CADx (ICADx) framework. The proposed framework is devised with a generative adversarial network, which consists of interpretable diagnosis network and synthetic lesion generative network to learn the relationship between malignancy and a standardized description (BI-RADS). The lesion generative network and the interpretable diagnosis network compete in an adversarial learning so that the two networks are improved. The effectiveness of the proposed method was validated on public mammogram database. Experimental results showed that the proposed ICADx framework could provide the interpretability of mass as well as mass classification. It was mainly attributed to the fact that the proposed method was effectively trained to find the relationship between malignancy and interpretations via the adversarial learning. These results imply that the proposed ICADx framework could be a promising approach to develop the CADx system.

  9. Computer-Aided Sensor Development Focused on Security Issues

    Directory of Open Access Journals (Sweden)

    Andrzej Bialas

    2016-05-01

    Full Text Available The paper examines intelligent sensor and sensor system development according to the Common Criteria methodology, which is the basic security assurance methodology for IT products and systems. The paper presents how the development process can be supported by software tools, design patterns and knowledge engineering. The automation of this process brings cost-, quality-, and time-related advantages, because the most difficult and most laborious activities are software-supported and the design reusability is growing. The paper includes a short introduction to the Common Criteria methodology and its sensor-related applications. In the experimental section the computer-supported and patterns-based IT security development process is presented using the example of an intelligent methane detection sensor. This process is supported by an ontology-based tool for security modeling and analyses. The verified and justified models are transferred straight to the security target specification representing security requirements for the IT product. The novelty of the paper is to provide a patterns-based and computer-aided methodology for the sensors development with a view to achieving their IT security assurance. The paper summarizes the validation experiment focused on this methodology adapted for the sensors system development, and presents directions of future research.

  10. Latest developments for a computer aided thermohydraulic network

    International Nuclear Information System (INIS)

    Alemberti, A.; Graziosi, G.; Mini, G.; Susco, M.

    1999-01-01

    Thermohydraulic networks are I-D systems characterized by a small number of basic components (pumps, valves, heat exchangers, etc) connected by pipes and limited spatially by a defined number of boundary conditions (tanks, atmosphere, etc). The network system is simulated by the well known computer program RELAPS/mod3. Information concerning the network geometry component behaviour, initial and boundary conditions are usually supplied to the RELAPS code using an ASCII input file by means of 'input cards'. CATNET (Computer Aided Thermalhydraulic NETwork) is a graphically user interface that, under specific user guidelines which completely define its range of applicability, permits a very high level of standardization and simplification of the RELAPS/mod3 input deck development process as well as of the output processing. The characteristics of the components (pipes, valves, pumps etc), defining the network system can be entered through CATNET. The CATNET interface is provided by special functions to compute form losses in the most typical bending and branching configurations. When the input of all system components is ready, CATNET is able to generate the RELAPS/mod3 input file. Finally, by means of CATNET, the RELAPS/mod3 code can be run and its output results can be transformed to an intuitive display form. The paper presents an example of application of the CATNET interface as well as the latest developments which greatly simplified the work of the users and allowed to reduce the possibility of input errors. (authors)

  11. Computer-Aided Sensor Development Focused on Security Issues.

    Science.gov (United States)

    Bialas, Andrzej

    2016-05-26

    The paper examines intelligent sensor and sensor system development according to the Common Criteria methodology, which is the basic security assurance methodology for IT products and systems. The paper presents how the development process can be supported by software tools, design patterns and knowledge engineering. The automation of this process brings cost-, quality-, and time-related advantages, because the most difficult and most laborious activities are software-supported and the design reusability is growing. The paper includes a short introduction to the Common Criteria methodology and its sensor-related applications. In the experimental section the computer-supported and patterns-based IT security development process is presented using the example of an intelligent methane detection sensor. This process is supported by an ontology-based tool for security modeling and analyses. The verified and justified models are transferred straight to the security target specification representing security requirements for the IT product. The novelty of the paper is to provide a patterns-based and computer-aided methodology for the sensors development with a view to achieving their IT security assurance. The paper summarizes the validation experiment focused on this methodology adapted for the sensors system development, and presents directions of future research.

  12. ARCHITECTURE OF WEB BASED COMPUTER-AIDED MANUFACTURING SYSTEM

    Directory of Open Access Journals (Sweden)

    N. E. Filyukov

    2014-09-01

    Full Text Available The paper deals with design of a web-based system for Computer-Aided Manufacturing (CAM. Remote applications and databases located in the "private cloud" are proposed to be the basis of such system. The suggested approach contains: service - oriented architecture, using web applications and web services as modules, multi-agent technologies for implementation of information exchange functions between the components of the system and the usage of PDM - system for managing technology projects within the CAM. The proposed architecture involves CAM conversion into the corporate information system that will provide coordinated functioning of subsystems based on a common information space, as well as parallelize collective work on technology projects and be able to provide effective control of production planning. A system has been developed within this architecture which gives the possibility for a rather simple technological subsystems connect to the system and implementation of their interaction. The system makes it possible to produce CAM configuration for a particular company on the set of developed subsystems and databases specifying appropriate access rights for employees of the company. The proposed approach simplifies maintenance of software and information support for CAM subsystems due to their central location in the data center. The results can be used as a basis for CAM design and testing within the learning process for development and modernization of the system algorithms, and then can be tested in the extended enterprise.

  13. The Effects of Computer-Aided Design Software on Engineering Students' Spatial Visualisation Skills

    Science.gov (United States)

    Kösa, Temel; Karakus, Fatih

    2018-01-01

    The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations…

  14. Enabling Lean Design Through Computer Aided Synthesis: The Injection Moulding Cooling Case

    NARCIS (Netherlands)

    Jauregui Becker, Juan Manuel; Wits, Wessel Willems

    2015-01-01

    This paper explores the application of Computer Aided Synthesis (CAS) to support the implementation of Set-Based Concurrent Engineering (SBCE) and Just In Time Decision Making (JIT-DM), which are considered as two of the cornerstones of the Lean Design method. Computer Aided Synthesis refers to a

  15. Teaching Computer-Aided Design of Fluid Flow and Heat Transfer Engineering Equipment.

    Science.gov (United States)

    Gosman, A. D.; And Others

    1979-01-01

    Describes a teaching program for fluid mechanics and heat transfer which contains both computer aided learning (CAL) and computer aided design (CAD) components and argues that the understanding of the physical and numerical modeling taught in the CAL course is essential to the proper implementation of CAD. (Author/CMV)

  16. Computer-aided Framework for Design of Pure, Mixed and Blended Products

    DEFF Research Database (Denmark)

    Cignitti, Stefano; Zhang, Lei; Gani, Rafiqul

    2015-01-01

    This paper presents a framework for computer-aided design of pure, mixed and blended chemical based products. The framework is a systematic approach to convert a Computer-aided Molecular, Mixture and Blend Design (CAMbD) formulation, based on needs and target properties, into a mixed integer non...

  17. [The automatic iris map overlap technology in computer-aided iridiagnosis].

    Science.gov (United States)

    He, Jia-feng; Ye, Hu-nian; Ye, Miao-yuan

    2002-11-01

    In the paper, iridology and computer-aided iridiagnosis technologies are briefly introduced and the extraction method of the collarette contour is then investigated. The iris map can be overlapped on the original iris image based on collarette contour extraction. The research on collarette contour extraction and iris map overlap is of great importance to computer-aided iridiagnosis technologies.

  18. Computer-aided bone age assessment for ethnically diverse older children using integrated fuzzy logic system

    Science.gov (United States)

    Ma, Kevin; Moin, Paymann; Zhang, Aifeng; Liu, Brent

    2010-03-01

    Bone Age Assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on the left hand x-ray radiograph. The current BAA standard in the US is using the Greulich & Pyle (G&P) Hand Atlas, which was developed fifty years ago and was only based on Caucasian population from the Midwest US. To bring the BAA procedure up-to-date with today's population, a Digital Hand Atlas (DHA) consisting of 1400 hand images of normal children of different ethnicities, age, and gender. Based on the DHA and to solve inter- and intra-observer reading discrepancies, an automatic computer-aided bone age assessment system has been developed and tested in clinical environments. The algorithm utilizes features extracted from three regions of interests: phalanges, carpal, and radius. The features are aggregated into a fuzzy logic system, which outputs the calculated bone age. The previous BAA system only uses features from phalanges and carpal, thus BAA result for children over age of 15 is less accurate. In this project, the new radius features are incorporated into the overall BAA system. The bone age results, calculated from the new fuzzy logic system, are compared against radiologists' readings based on G&P atlas, and exhibits an improvement in reading accuracy for older children.

  19. Computer-aided diagnosis of mammographic masses using geometric verification-based image retrieval

    Science.gov (United States)

    Li, Qingliang; Shi, Weili; Yang, Huamin; Zhang, Huimao; Li, Guoxin; Chen, Tao; Mori, Kensaku; Jiang, Zhengang

    2017-03-01

    Computer-Aided Diagnosis of masses in mammograms is an important indicator of breast cancer. The use of retrieval systems in breast examination is increasing gradually. In this respect, the method of exploiting the vocabulary tree framework and the inverted file in the mammographic masse retrieval have been proved high accuracy and excellent scalability. However it just considered the features in each image as a visual word and had ignored the spatial configurations of features. It greatly affect the retrieval performance. To overcome this drawback, we introduce the geometric verification method to retrieval in mammographic masses. First of all, we obtain corresponding match features based on the vocabulary tree framework and the inverted file. After that, we grasps the main point of local similarity characteristic of deformations in the local regions by constructing the circle regions of corresponding pairs. Meanwhile we segment the circle to express the geometric relationship of local matches in the area and generate the spatial encoding strictly. Finally we judge whether the matched features are correct or not, based on verifying the all spatial encoding are whether satisfied the geometric consistency. Experiments show the promising results of our approach.

  20. Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments.

    Science.gov (United States)

    Stona, Deborah; Burnett, Luiz Henrique; Mota, Eduardo Gonçalves; Spohr, Ana Maria

    2015-07-01

    Because no information was found in the dental literature regarding the fracture resistance of all-ceramic crowns using CEREC (Sirona) computer-aided design and computer-aided manufacturing (CAD-CAM) system on solid abutments, the authors conducted a study. Sixty synOcta (Straumann) implant replicas and regular neck solid abutments were embedded in acrylic resin and randomly assigned (n = 20 per group). Three types of ceramics were used: feldspathic, CEREC VITABLOCS Mark II (VITA); leucite, IPS Empress CAD (Ivoclar Vivadent); and lithium disilicate, IPS e.max CAD (Ivoclar Vivadent). The crowns were fabricated by the CEREC CAD-CAM system. After receiving glaze, the crowns were cemented with RelyX U200 (3M ESPE) resin cement under load of 1 kilogram. For each ceramic, one-half of the specimens were subjected to the fracture resistance testing in a universal testing machine with a crosshead speed of 1 millimeter per minute, and the other half were subjected to the fractured resistance testing after 1,000,000 cyclic fatigue loading at 100 newtons. According to a 2-way analysis of variance, the interaction between the material and mechanical cycling was significant (P = .0001). According to a Tukey test (α = .05), the fracture resistance findings with or without cyclic fatigue loading were as follows, respectively: CEREC VITABLOCKS Mark II (405 N/454 N) was statistically lower than IPS Empress CAD (1169 N/1240 N) and IPS e.max CAD (1378 N/1025 N) (P Empress CAD and IPS e.max CAD did not differ statistically (P > .05). According to a t test, there was no statistical difference in the fracture resistance with and without cyclic fatigue loading for CEREC VITABLOCS Mark II and IPS Empress CAD (P > .05). For IPS e.max CAD, the fracture resistance without cyclic fatigue loading was statistically superior to that obtained with cyclic fatigue loading (P Empress CAD and IPS e.max CAD showed higher fracture resistance compared with CEREC VITABLOCS Mark II. The cyclic

  1. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration

    Directory of Open Access Journals (Sweden)

    Juntavee N

    2018-02-01

    Full Text Available Niwut Juntavee,1 Issarawas Sirisathit2 1Department of Prosthodontics, 2Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand Objective: This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM systems (Trios-3 and CS3500 in comparison to conventional cast metal restoration. Materials and methods: A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel–chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA and Tukey’s honest significant difference (HSD multiple comparisons were used to determine statistically significant difference at 95% confidence interval. Results: The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system (p<0.05. Tukey’s HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration (p<0.05. Conclusion: Full

  2. Computer aided instrumented Charpy test applied dynamic fracture toughness evaluation system

    International Nuclear Information System (INIS)

    Kobayashi, Toshiro; Niinomi, Mitsuo

    1986-01-01

    Micro computer aided data treatment system and personal computer aided data analysis system were applied to the traditional instrumented Charpy impact test system. The analysis of Charpy absorbed energy (E i , E p , E t ) and load (P y , P m ), and the evaluation of dynamic toughness through whole fracture process, i.e. J Id , J R curve and T mat was examined using newly developed computer aided instrumented Charpy impact test system. E i , E p , E t , P y and P m were effectively analyzed using moving average method and printed out automatically by micro computer aided data treatment system. J Id , J R curve and T mat could be measured by stop block test method. Then, J Id , J R curve and T mat were effectively estimated using compliance changing rate method and key curve method on the load-load point displacement curve of single fatigue cracked specimen by personal computer aided data analysis system. (author)

  3. [Development of computer aided forming techniques in manufacturing scaffolds for bone tissue engineering].

    Science.gov (United States)

    Wei, Xuelei; Dong, Fuhui

    2011-12-01

    To review recent advance in the research and application of computer aided forming techniques for constructing bone tissue engineering scaffolds. The literature concerning computer aided forming techniques for constructing bone tissue engineering scaffolds in recent years was reviewed extensively and summarized. Several studies over last decade have focused on computer aided forming techniques for bone scaffold construction using various scaffold materials, which is based on computer aided design (CAD) and bone scaffold rapid prototyping (RP). CAD include medical CAD, STL, and reverse design. Reverse design can fully simulate normal bone tissue and could be very useful for the CAD. RP techniques include fused deposition modeling, three dimensional printing, selected laser sintering, three dimensional bioplotting, and low-temperature deposition manufacturing. These techniques provide a new way to construct bone tissue engineering scaffolds with complex internal structures. With rapid development of molding and forming techniques, computer aided forming techniques are expected to provide ideal bone tissue engineering scaffolds.

  4. Computer aided diagnosis based on medical image processing and artificial intelligence methods

    Science.gov (United States)

    Stoitsis, John; Valavanis, Ioannis; Mougiakakou, Stavroula G.; Golemati, Spyretta; Nikita, Alexandra; Nikita, Konstantina S.

    2006-12-01

    Advances in imaging technology and computer science have greatly enhanced interpretation of medical images, and contributed to early diagnosis. The typical architecture of a Computer Aided Diagnosis (CAD) system includes image pre-processing, definition of region(s) of interest, features extraction and selection, and classification. In this paper, the principles of CAD systems design and development are demonstrated by means of two examples. The first one focuses on the differentiation between symptomatic and asymptomatic carotid atheromatous plaques. For each plaque, a vector of texture and motion features was estimated, which was then reduced to the most robust ones by means of ANalysis of VAriance (ANOVA). Using fuzzy c-means, the features were then clustered into two classes. Clustering performances of 74%, 79%, and 84% were achieved for texture only, motion only, and combinations of texture and motion features, respectively. The second CAD system presented in this paper supports the diagnosis of focal liver lesions and is able to characterize liver tissue from Computed Tomography (CT) images as normal, hepatic cyst, hemangioma, and hepatocellular carcinoma. Five texture feature sets were extracted for each lesion, while a genetic algorithm based feature selection method was applied to identify the most robust features. The selected feature set was fed into an ensemble of neural network classifiers. The achieved classification performance was 100%, 93.75% and 90.63% in the training, validation and testing set, respectively. It is concluded that computerized analysis of medical images in combination with artificial intelligence can be used in clinical practice and may contribute to more efficient diagnosis.

  5. Computer aided diagnosis based on medical image processing and artificial intelligence methods

    International Nuclear Information System (INIS)

    Stoitsis, John; Valavanis, Ioannis; Mougiakakou, Stavroula G.; Golemati, Spyretta; Nikita, Alexandra; Nikita, Konstantina S.

    2006-01-01

    Advances in imaging technology and computer science have greatly enhanced interpretation of medical images, and contributed to early diagnosis. The typical architecture of a Computer Aided Diagnosis (CAD) system includes image pre-processing, definition of region(s) of interest, features extraction and selection, and classification. In this paper, the principles of CAD systems design and development are demonstrated by means of two examples. The first one focuses on the differentiation between symptomatic and asymptomatic carotid atheromatous plaques. For each plaque, a vector of texture and motion features was estimated, which was then reduced to the most robust ones by means of ANalysis of VAriance (ANOVA). Using fuzzy c-means, the features were then clustered into two classes. Clustering performances of 74%, 79%, and 84% were achieved for texture only, motion only, and combinations of texture and motion features, respectively. The second CAD system presented in this paper supports the diagnosis of focal liver lesions and is able to characterize liver tissue from Computed Tomography (CT) images as normal, hepatic cyst, hemangioma, and hepatocellular carcinoma. Five texture feature sets were extracted for each lesion, while a genetic algorithm based feature selection method was applied to identify the most robust features. The selected feature set was fed into an ensemble of neural network classifiers. The achieved classification performance was 100%, 93.75% and 90.63% in the training, validation and testing set, respectively. It is concluded that computerized analysis of medical images in combination with artificial intelligence can be used in clinical practice and may contribute to more efficient diagnosis

  6. Computer aided diagnosis based on medical image processing and artificial intelligence methods

    Energy Technology Data Exchange (ETDEWEB)

    Stoitsis, John [National Technical University of Athens, School of Electrical and Computer Engineering, Athens 157 71 (Greece)]. E-mail: stoitsis@biosim.ntua.gr; Valavanis, Ioannis [National Technical University of Athens, School of Electrical and Computer Engineering, Athens 157 71 (Greece); Mougiakakou, Stavroula G. [National Technical University of Athens, School of Electrical and Computer Engineering, Athens 157 71 (Greece); Golemati, Spyretta [National Technical University of Athens, School of Electrical and Computer Engineering, Athens 157 71 (Greece); Nikita, Alexandra [University of Athens, Medical School 152 28 Athens (Greece); Nikita, Konstantina S. [National Technical University of Athens, School of Electrical and Computer Engineering, Athens 157 71 (Greece)

    2006-12-20

    Advances in imaging technology and computer science have greatly enhanced interpretation of medical images, and contributed to early diagnosis. The typical architecture of a Computer Aided Diagnosis (CAD) system includes image pre-processing, definition of region(s) of interest, features extraction and selection, and classification. In this paper, the principles of CAD systems design and development are demonstrated by means of two examples. The first one focuses on the differentiation between symptomatic and asymptomatic carotid atheromatous plaques. For each plaque, a vector of texture and motion features was estimated, which was then reduced to the most robust ones by means of ANalysis of VAriance (ANOVA). Using fuzzy c-means, the features were then clustered into two classes. Clustering performances of 74%, 79%, and 84% were achieved for texture only, motion only, and combinations of texture and motion features, respectively. The second CAD system presented in this paper supports the diagnosis of focal liver lesions and is able to characterize liver tissue from Computed Tomography (CT) images as normal, hepatic cyst, hemangioma, and hepatocellular carcinoma. Five texture feature sets were extracted for each lesion, while a genetic algorithm based feature selection method was applied to identify the most robust features. The selected feature set was fed into an ensemble of neural network classifiers. The achieved classification performance was 100%, 93.75% and 90.63% in the training, validation and testing set, respectively. It is concluded that computerized analysis of medical images in combination with artificial intelligence can be used in clinical practice and may contribute to more efficient diagnosis.

  7. CAISSE (Computer Aided Information System on Solar Energy) technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Cantelon, P E; Beinhauer, F W

    1979-01-01

    The Computer Aided Information System on Solar Energy (CAISSE) was developed to provide the general public with information on solar energy and its potential uses and costs for domestic consumption. CAISSE is an interactive computing system which illustrates solar heating concepts through the use of 35 mm slides, text displays on a screen and a printed report. The user communicates with the computer by responding to questions about his home and heating requirements through a touch sensitive screen. The CAISSE system contains a solar heating simulation model which calculates the heating load capable of being supplied by a solar heating system and uses this information to illustrate installation costs, fuel savings and a 20 year life-cycle analysis of cost and benefits. The system contains several sets of radiation and weather data for Canada and USA. The selection of one of four collector models is based upon the requirements input during the computer session. Optimistic and pessimistic fuel cost forecasts are made for oil, natural gas, electricity, or propane; and the forecasted fuel cost is made the basis of the life cycle cost evaluation for the solar heating application chosen. This manual is organized so that each section describes one major aspect of the use of solar energy systems to provide energy for domestic consumption. The sources of data and technical information and the method of incorporating them into the CAISSE display system are described in the same order as the computer processing. Each section concludes with a list of future developments that could be included to make CAISSE outputs more regionally specific and more useful to designers. 19 refs., 1 tab.

  8. Local pulmonary structure classification for computer-aided nodule detection

    Science.gov (United States)

    Bahlmann, Claus; Li, Xianlin; Okada, Kazunori

    2006-03-01

    We propose a new method of classifying the local structure types, such as nodules, vessels, and junctions, in thoracic CT scans. This classification is important in the context of computer aided detection (CAD) of lung nodules. The proposed method can be used as a post-process component of any lung CAD system. In such a scenario, the classification results provide an effective means of removing false positives caused by vessels and junctions thus improving overall performance. As main advantage, the proposed solution transforms the complex problem of classifying various 3D topological structures into much simpler 2D data clustering problem, to which more generic and flexible solutions are available in literature, and which is better suited for visualization. Given a nodule candidate, first, our solution robustly fits an anisotropic Gaussian to the data. The resulting Gaussian center and spread parameters are used to affine-normalize the data domain so as to warp the fitted anisotropic ellipsoid into a fixed-size isotropic sphere. We propose an automatic method to extract a 3D spherical manifold, containing the appropriate bounding surface of the target structure. Scale selection is performed by a data driven entropy minimization approach. The manifold is analyzed for high intensity clusters, corresponding to protruding structures. Techniques involve EMclustering with automatic mode number estimation, directional statistics, and hierarchical clustering with a modified Bhattacharyya distance. The estimated number of high intensity clusters explicitly determines the type of pulmonary structures: nodule (0), attached nodule (1), vessel (2), junction (>3). We show accurate classification results for selected examples in thoracic CT scans. This local procedure is more flexible and efficient than current state of the art and will help to improve the accuracy of general lung CAD systems.

  9. Computer-aided pulmonary image analysis in small animal models

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ziyue; Mansoor, Awais; Mollura, Daniel J. [Center for Infectious Disease Imaging (CIDI), Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Bagci, Ulas, E-mail: ulasbagci@gmail.com [Center for Research in Computer Vision (CRCV), University of Central Florida (UCF), Orlando, Florida 32816 (United States); Kramer-Marek, Gabriela [The Institute of Cancer Research, London SW7 3RP (United Kingdom); Luna, Brian [Microfluidic Laboratory Automation, University of California-Irvine, Irvine, California 92697-2715 (United States); Kubler, Andre [Department of Medicine, Imperial College London, London SW7 2AZ (United Kingdom); Dey, Bappaditya; Jain, Sanjay [Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Foster, Brent [Department of Biomedical Engineering, University of California-Davis, Davis, California 95817 (United States); Papadakis, Georgios Z. [Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Camp, Jeremy V. [Department of Microbiology and Immunology, University of Louisville, Louisville, Kentucky 40202 (United States); Jonsson, Colleen B. [National Institute for Mathematical and Biological Synthesis, University of Tennessee, Knoxville, Tennessee 37996 (United States); Bishai, William R. [Howard Hughes Medical Institute, Chevy Chase, Maryland 20815 and Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Udupa, Jayaram K. [Medical Image Processing Group, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2015-07-15

    Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

  10. Computer Aided Design of a Low-Cost Painting Robot

    Directory of Open Access Journals (Sweden)

    SYEDA MARIA KHATOON ZAIDI

    2017-10-01

    Full Text Available The application of robots or robotic systems for painting parts is becoming increasingly conventional; to improve reliability, productivity, consistency and to decrease waste. However, in Pakistan only highend Industries are able to afford the luxury of a robotic system for various purposes. In this study we propose an economical Painting Robot that a small-scale industry can install in their plant with ease. The importance of this robot is that being cost effective, it can easily be replaced in small manufacturing industries and therefore, eliminate health problems occurring to the individual in charge of painting parts on an everyday basis. To achieve this aim, the robot is made with local parts with only few exceptions, to cut costs; and the programming language is kept at a mediocre level. Image processing is used to establish object recognition and it can be programmed to paint various simple geometries. The robot is placed on a conveyer belt to maximize productivity. A four DoF (Degree of Freedom arm increases the working envelope and accessibility of painting different shaped parts with ease. This robot is capable of painting up, front, back, left and right sides of the part with a single colour. Initially CAD (Computer Aided Design models of the robot were developed which were analyzed, modified and improved to withstand loading condition and perform its task efficiently. After design selection, appropriate motors and materials were selected and the robot was developed. Throughout the development phase, minor problems and errors were fixed accordingly as they arose. Lastly the robot was integrated with the computer and image processing for autonomous control. The final results demonstrated that the robot is economical and reduces paint wastage.

  11. Computer aided design of a low-cost painting robot

    International Nuclear Information System (INIS)

    Zaidi, S.M.; Janejo, F.; Mujtaba, S.B.

    2017-01-01

    The application of robots or robotic systems for painting parts is becoming increasingly conventional; to improve reliability, productivity, consistency and to decrease waste. However, in Pakistan only highend Industries are able to afford the luxury of a robotic system for various purposes. In this study we propose an economical Painting Robot that a small-scale industry can install in their plant with ease. The importance of this robot is that being cost effective, it can easily be replaced in small manufacturing industries and therefore, eliminate health problems occurring to the individual in charge of painting parts on an everyday basis. To achieve this aim, the robot is made with local parts with only few exceptions, to cut costs; and the programming language is kept at a mediocre level. Image processing is used to establish object recognition and it can be programmed to paint various simple geometries. The robot is placed on a conveyer belt to maximize productivity. A four DoF (Degree of Freedom) arm increases the working envelope and accessibility of painting different shaped parts with ease. This robot is capable of painting up, front, back, left and right sides of the part with a single colour. Initially CAD (Computer Aided Design) models of the robot were developed which were analyzed, modified and improved to withstand loading condition and perform its task efficiently. After design selection, appropriate motors and materials were selected and the robot was developed. Throughout the development phase, minor problems and errors were fixed accordingly as they arose. Lastly the robot was integrated with the computer and image processing for autonomous control. The final results demonstrated that the robot is economical and reduces paint wastage. (author)

  12. A Learning Health Care System Using Computer-Aided Diagnosis.

    Science.gov (United States)

    Cahan, Amos; Cimino, James J

    2017-03-08

    Physicians intuitively apply pattern recognition when evaluating a patient. Rational diagnosis making requires that clinical patterns be put in the context of disease prior probability, yet physicians often exhibit flawed probabilistic reasoning. Difficulties in making a diagnosis are reflected in the high rates of deadly and costly diagnostic errors. Introduced 6 decades ago, computerized diagnosis support systems are still not widely used by internists. These systems cannot efficiently recognize patterns and are unable to consider the base rate of potential diagnoses. We review the limitations of current computer-aided diagnosis support systems. We then portray future diagnosis support systems and provide a conceptual framework for their development. We argue for capturing physician knowledge using a novel knowledge representation model of the clinical picture. This model (based on structured patient presentation patterns) holds not only symptoms and signs but also their temporal and semantic interrelations. We call for the collection of crowdsourced, automatically deidentified, structured patient patterns as means to support distributed knowledge accumulation and maintenance. In this approach, each structured patient pattern adds to a self-growing and -maintaining knowledge base, sharing the experience of physicians worldwide. Besides supporting diagnosis by relating the symptoms and signs with the final diagnosis recorded, the collective pattern map can also provide disease base-rate estimates and real-time surveillance for early detection of outbreaks. We explain how health care in resource-limited settings can benefit from using this approach and how it can be applied to provide feedback-rich medical education for both students and practitioners. ©Amos Cahan, James J Cimino. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 08.03.2017.

  13. Computer-aided diagnosis scheme for histological classification of clustered microcalcifications on magnification mammograms

    International Nuclear Information System (INIS)

    Nakayama, Ryohei; Uchiyama, Yoshikazu; Watanabe, Ryoji; Katsuragawa, Shigehiko; Namba, Kiyoshi; Doi, Kunio

    2004-01-01

    The histological classification of clustered microcalcifications on mammograms can be difficult, and thus often require biopsy or follow-up. Our purpose in this study was to develop a computer-aided diagnosis schemefor identifying the histological classification of clustered microcalcifications on magnification mammograms in order to assist the radiologists' interpretation as a 'second opinion'. Our database consisted of 58 magnification mammograms, which included 35 malignant clustered microcalcifications (9 invasive carcinomas, 12 noninvasive carcinomas of the comedo type, and 14 noninvasive carcinomas of the noncomedo type) and 23 benign clustered microcalcifications (17 mastopathies and 6 fibroadenomas). The histological classifications of all clustered microcalcifications were proved by pathologic diagnosis. The clustered microcalcifications were first segmented by use of a novel filter bank and a thresholding technique. Five objective features on clustered microcalcifications were determined by taking into account subjective features that experienced the radiologists commonly use to identify possible histological classifications. The Bayes decision rule with five objective features was employed for distinguishing between five histological classifications. The classification accuracies for distinguishing between three malignant histological classifications were 77.8% (7/9) for invasive carcinoma, 75.0% (9/12) for noninvasive carcinoma of the comedo type, and 92.9% (13/14) for noninvasive carcinoma of the noncomedo type. The classification accuracies for distinguishing between two benign histological classifications were 94.1% (16/17) for mastopathy, and 100.0% (6/6) for fibroadenoma. This computerized method would be useful in assisting radiologists in their assessments of clustered microcalcifications

  14. A new approach to develop computer-aided detection schemes of digital mammograms

    Science.gov (United States)

    Tan, Maxine; Qian, Wei; Pu, Jiantao; Liu, Hong; Zheng, Bin

    2015-06-01

    The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening examinations was used in this study. Among them, 812 cases were positive for cancer and 1084 were negative or benign. After segmenting the breast area, a computerized scheme was applied to compute 92 global mammographic tissue density based features on each of four mammograms of the craniocaudal (CC) and mediolateral oblique (MLO) views. After adding three existing popular risk factors (woman’s age, subjectively rated mammographic density, and family breast cancer history) into the initial feature pool, we applied a sequential forward floating selection feature selection algorithm to select relevant features from the bilateral CC and MLO view images separately. The selected CC and MLO view image features were used to train two artificial neural networks (ANNs). The results were then fused by a third ANN to build a two-stage classifier to predict the likelihood of the FFDM screening examination being positive. CAD performance was tested using a ten-fold cross-validation method. The computed area under the receiver operating characteristic curve was AUC = 0.779   ±   0.025 and the odds ratio monotonically increased from 1 to 31.55 as CAD-generated detection scores increased. The study demonstrated that this new global image feature based CAD scheme had a relatively higher discriminatory power to cue the FFDM examinations with high risk of being positive, which may provide a new CAD-cueing method to assist radiologists in reading and interpreting screening mammograms.

  15. Implementation and display of Computer Aided Design (CAD) models in Monte Carlo radiation transport and shielding applications

    International Nuclear Information System (INIS)

    Burns, T.J.

    1994-01-01

    An Xwindow application capable of importing geometric information directly from two Computer Aided Design (CAD) based formats for use in radiation transport and shielding analyses is being developed at ORNL. The application permits the user to graphically view the geometric models imported from the two formats for verification and debugging. Previous models, specifically formatted for the radiation transport and shielding codes can also be imported. Required extensions to the existing combinatorial geometry analysis routines are discussed. Examples illustrating the various options and features which will be implemented in the application are presented. The use of the application as a visualization tool for the output of the radiation transport codes is also discussed

  16. On the Value of Computer-aided Instruction: Thoughts after Teaching Sales Writing in a Computer Classroom.

    Science.gov (United States)

    Hagge, John

    1986-01-01

    Focuses on problems encountered with computer-aided writing instruction. Discusses conflicts caused by the computer classroom concept, some general paradoxes and ethical implications of computer-aided instruction. (EL)

  17. Development of the computer-aided process planning (CAPP system for polymer injection molds manufacturing

    Directory of Open Access Journals (Sweden)

    J. Tepić

    2011-10-01

    Full Text Available Beginning of production and selling of polymer products largely depends on mold manufacturing. The costs of mold manufacturing have significant share in the final price of a product. The best way to improve and rationalize polymer injection molds production process is by doing mold design automation and manufacturing process planning automation. This paper reviews development of a dedicated process planning system for manufacturing of the mold for injection molding, which integrates computer-aided design (CAD, computer-aided process planning (CAPP and computer-aided manufacturing (CAM technologies.

  18. Influence of tritium aging on kinetics feature of LaNi4.9Al0.1

    International Nuclear Information System (INIS)

    Xiong Yifu; Luo Deli; Li Rong

    2001-01-01

    Kinetics parameters were measured at different aging time on LaNi 4.9 Al 0.1 alloy. The influence of tritium aging on kinetics feature of LaNi 4.9 Al 0.1 alloy was assessed. The results show that tritium aging does not change deuterating-dedeuterating reaction order. Reaction rate decrease with aging time. Activation energy (E) increases with aging time

  19. A computer aided treatment event recognition system in radiation therapy

    International Nuclear Information System (INIS)

    Xia, Junyi; Mart, Christopher; Bayouth, John

    2014-01-01

    Purpose: To develop an automated system to safeguard radiation therapy treatments by analyzing electronic treatment records and reporting treatment events. Methods: CATERS (Computer Aided Treatment Event Recognition System) was developed to detect treatment events by retrieving and analyzing electronic treatment records. CATERS is designed to make the treatment monitoring process more efficient by automating the search of the electronic record for possible deviations from physician's intention, such as logical inconsistencies as well as aberrant treatment parameters (e.g., beam energy, dose, table position, prescription change, treatment overrides, etc). Over a 5 month period (July 2012–November 2012), physicists were assisted by the CATERS software in conducting normal weekly chart checks with the aims of (a) determining the relative frequency of particular events in the authors’ clinic and (b) incorporating these checks into the CATERS. During this study period, 491 patients were treated at the University of Iowa Hospitals and Clinics for a total of 7692 fractions. Results: All treatment records from the 5 month analysis period were evaluated using all the checks incorporated into CATERS after the training period. About 553 events were detected as being exceptions, although none of them had significant dosimetric impact on patient treatments. These events included every known event type that was discovered during the trial period. A frequency analysis of the events showed that the top three types of detected events were couch position override (3.2%), extra cone beam imaging (1.85%), and significant couch position deviation (1.31%). The significant couch deviation is defined as the number of treatments where couch vertical exceeded two times standard deviation of all couch verticals, or couch lateral/longitudinal exceeded three times standard deviation of all couch laterals and longitudinals. On average, the application takes about 1 s per patient when

  20. Reproducibility of computer-aided detection system in digital mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Cho, Nariya; Cha, Joo Hee; Chung, Hye Kyung; Lee, Sin Ho; Cho, Kyung Soo; Kim, Sun Mi; Moon, Woo Kyung

    2005-01-01

    To evaluate the reproducibility of the computer-aided detection (CAD) system for digital mammograms. We applied the CAD system (ImageChecker M1000-DM, version 3.1; R2 Technology) to full field digital mammograms. These mammograms were taken twice at an interval of 10-45 days (mean:25 days) for 34 preoperative patients (breast cancer n=27, benign disease n=7, age range:20-66 years, mean age:47.9 years). On the mammograms, lesions were visible in 19 patients and these were depicted as 15 masses and 12 calcification clusters. We analyzed the sensitivity, the false positive rate (FPR) and the reproducibility of the CAD marks. The broader sensitivities of the CAD system were 80% (12 of 15), 67%(10 of 15) for masses and those for calcification clusters were 100% (12 of 12). The strict sensitivities were 50% (15 of 30) and 50% (15 of 30) for masses and 92% (22 of 24) and 79% (19 of 24) for the clusters. The FPR for the masses was 0.21-0.22/image, the FPR for the clusters was 0.03-0.04/image and the total FPR was 0.24-0.26/image. Among 132 mammography images, the identical images regardless of the existence of CAD marks were 59% (78 of 132), and the identical images with CAD marks were 22% (15 of 69). The reproducibility of the CAD marks for the true positive mass was 67% (12 of 18) and 71% (17 of 24) for the true positive cluster. The reproducibility of CAD marks for the false positive mass was 8% (4 of 53), and the reproducibility of CAD marks for the false positive clusters was 14% (1 of 7). The reproducibility of the total mass marks was 23% (16 of 71), and the reproducibility of the total cluster marks was 58% (18 of 31). CAD system showed higher sensitivity and reproducibility of CAD marks for the calcification clusters which are related to breast cancer. Yet the overall reproducibility of CAD marks was low; therefore, the CAD system must be applied considering this limitation

  1. Machine Learning in Computer-Aided Synthesis Planning.

    Science.gov (United States)

    Coley, Connor W; Green, William H; Jensen, Klavs F

    2018-05-15

    Computer-aided synthesis planning (CASP) is focused on the goal of accelerating the process by which chemists decide how to synthesize small molecule compounds. The ideal CASP program would take a molecular structure as input and output a sorted list of detailed reaction schemes that each connect that target to purchasable starting materials via a series of chemically feasible reaction steps. Early work in this field relied on expert-crafted reaction rules and heuristics to describe possible retrosynthetic disconnections and selectivity rules but suffered from incompleteness, infeasible suggestions, and human bias. With the relatively recent availability of large reaction corpora (such as the United States Patent and Trademark Office (USPTO), Reaxys, and SciFinder databases), consisting of millions of tabulated reaction examples, it is now possible to construct and validate purely data-driven approaches to synthesis planning. As a result, synthesis planning has been opened to machine learning techniques, and the field is advancing rapidly. In this Account, we focus on two critical aspects of CASP and recent machine learning approaches to both challenges. First, we discuss the problem of retrosynthetic planning, which requires a recommender system to propose synthetic disconnections starting from a target molecule. We describe how the search strategy, necessary to overcome the exponential growth of the search space with increasing number of reaction steps, can be assisted through a learned synthetic complexity metric. We also describe how the recursive expansion can be performed by a straightforward nearest neighbor model that makes clever use of reaction data to generate high quality retrosynthetic disconnections. Second, we discuss the problem of anticipating the products of chemical reactions, which can be used to validate proposed reactions in a computer-generated synthesis plan (i.e., reduce false positives) to increase the likelihood of experimental success

  2. A computer aided treatment event recognition system in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Junyi, E-mail: junyi-xia@uiowa.edu; Mart, Christopher [Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Bayouth, John [Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, Iowa 52242 and Department of Human Oncology, University of Wisconsin - Madison, 600 Highland Avenue, K4/B55, Madison, Wisconsin 53792-0600 (United States)

    2014-01-15

    Purpose: To develop an automated system to safeguard radiation therapy treatments by analyzing electronic treatment records and reporting treatment events. Methods: CATERS (Computer Aided Treatment Event Recognition System) was developed to detect treatment events by retrieving and analyzing electronic treatment records. CATERS is designed to make the treatment monitoring process more efficient by automating the search of the electronic record for possible deviations from physician's intention, such as logical inconsistencies as well as aberrant treatment parameters (e.g., beam energy, dose, table position, prescription change, treatment overrides, etc). Over a 5 month period (July 2012–November 2012), physicists were assisted by the CATERS software in conducting normal weekly chart checks with the aims of (a) determining the relative frequency of particular events in the authors’ clinic and (b) incorporating these checks into the CATERS. During this study period, 491 patients were treated at the University of Iowa Hospitals and Clinics for a total of 7692 fractions. Results: All treatment records from the 5 month analysis period were evaluated using all the checks incorporated into CATERS after the training period. About 553 events were detected as being exceptions, although none of them had significant dosimetric impact on patient treatments. These events included every known event type that was discovered during the trial period. A frequency analysis of the events showed that the top three types of detected events were couch position override (3.2%), extra cone beam imaging (1.85%), and significant couch position deviation (1.31%). The significant couch deviation is defined as the number of treatments where couch vertical exceeded two times standard deviation of all couch verticals, or couch lateral/longitudinal exceeded three times standard deviation of all couch laterals and longitudinals. On average, the application takes about 1 s per patient when

  3. Computer-aided assessment of diagnostic images for epidemiological research

    Directory of Open Access Journals (Sweden)

    Gange Stephen J

    2009-11-01

    Full Text Available Abstract Background Diagnostic images are often assessed for clinical outcomes using subjective methods, which are limited by the skill of the reviewer. Computer-aided diagnosis (CAD algorithms that assist reviewers in their decisions concerning outcomes have been developed to increase sensitivity and specificity in the clinical setting. However, these systems have not been well utilized in research settings to improve the measurement of clinical endpoints. Reductions in bias through their use could have important implications for etiologic research. Methods Using the example of cortical cataract detection, we developed an algorithm for assisting a reviewer in evaluating digital images for the presence and severity of lesions. Available image processing and statistical methods that were easily implementable were used as the basis for the CAD algorithm. The performance of the system was compared to the subjective assessment of five reviewers using 60 simulated images. Cortical cataract severity scores from 0 to 16 were assigned to the images by the reviewers and the CAD system, with each image assessed twice to obtain a measure of variability. Image characteristics that affected reviewer bias were also assessed by systematically varying the appearance of the simulated images. Results The algorithm yielded severity scores with smaller bias on images where cataract severity was mild to moderate (approximately ≤ 6/16ths. On high severity images, the bias of the CAD system exceeded that of the reviewers. The variability of the CAD system was zero on repeated images but ranged from 0.48 to 1.22 for the reviewers. The direction and magnitude of the bias exhibited by the reviewers was a function of the number of cataract opacities, the shape and the contrast of the lesions in the simulated images. Conclusion CAD systems are feasible to implement with available software and can be valuable when medical images contain exposure or outcome information for

  4. Computer Aided Design of Polygalacturonase II from Aspergillus niger

    Directory of Open Access Journals (Sweden)

    Ibrahim Ali Noorbatcha

    2011-12-01

    Full Text Available Pectin is a complex polysaccharide found in the cell walls of plants and consisting mainly of esterified D-galacturonic acid resides in α-(1-4 chain. In production of fruit juice, pectin contributes to fruit juice viscosity, thereby reducing the juice production and increasing the filtration time. Polygalacturonase improves the juice production process by rapid degradation of pectin. In this project we have designed a novel polygalacturonase enzyme using computer aided design approaches. The three dimension structure of polygalacturonase is first modeled on the basis of the known crystal structure. The active site in this enzyme is identified by manual and automated docking methods. Lamarckian genetic algorithm is used for automated docking and the active site is validated by comparing with existing experimental data. This is followed by in silico mutations of the enzymes and the automated docking process is repeated using the mutant enzymes. The strength of the binding of the ligands inside the active site is evaluated by computing the binding score using Potential Mean Force (PMF method. The in silico mutations R256Q and K258N are found to decrease the binding strength of the ligand at the active site, indicating lowering of enzyme activity, which is consistent with the experimental results. Hence in silico mutations can be used to design new polygalacturonase enzymes with improved enzyme activity.ABSTRAK: Pektin adalah polisakarida kompleks yang terdapat di dalam dinding sel tumbuhan dan sebahagian besarnya terdiri daripada asid D-galakturonik terester yang ditemui di dalam rantaian α-(1-4. Dalam penghasilan jus buah-buahan, pektin menyumbang dalam kepekatan jus buah-buahan, di mana ia mengurangkan penghasilan jus dan menambahkan masa penapisan. Poligalakturonase meningkatkan proses penghasilan jus dengan pemecahan pektin dengan cepat. Dalam projek ini, kami telah merangka satu enzim poligalakturonase baru dengan menggunakan pendekatan reka

  5. Computer-aided pathophysiological analysis of /sup 131/I rose bengal hepatogram

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, A [Kobe Univ. (Japan). School of Medicine

    1976-06-01

    The author analysed /sup 131/I-rose bengal (R.B.) hepatograms over the liver region using digital simulation technique to determine the hepatobiliary functions separately and to compare the rate constants obtained from the kinetic model and the results obtained from conventional liver function tests. A total of 112 cases were observed including various liver and gallbladder diseases and 8 normal subjects. Fasting patients were given intravenous injections of 300 ..mu..Ci of /sup 131/I-R.B. Hepatic uptake and excretion of radioactivity were measured for 120 minutes using a gamma camera. Two regions, one over the right lobe and the other over the gallbladder, were studied. The author applied a 3 compartment analysis to the /sup 131/I-R.B. hepatogram. Measured /sup 131/I-R.B. hepatogram was printed out on a line printer with curve pattern indices. Assumed rate constants and relative volume indices were placed on punch cards. Computer-aided simulation curves were printed on a line printer with curve pattern indices. The measured hepatogram and the simulated hepatogram were compared. The blood flow index (K/sub 21/), the hepatocellular function index (K/sub 32/) and the intrahepatic biliary excretion index (K/sub 03/) were obtained with the schematic presentation of the curves. Rate constants from the kinetic model correlated well with conventional liver function tests. In normal liver and hepatobiliary diseases, there were high statistical correlations between K/sub 21/ and Ksub(L) /sup 131/I-R.B. Retention (%), between K/sub 32/ and Cholinesterase, and between K/sub 03/ and Alkaliphosphatase. However, there was a low statistical correlation between the results of the simulation study and the results of liver function tests in the cases of obstructive jaundice and intrahepatic cholestasis.

  6. Computer-aided pathophysiological analysis of 131I rose bengal hepatogram

    International Nuclear Information System (INIS)

    Matsumoto, Akira

    1976-01-01

    The author analysed 131 I-rose bengal (R.B.) hepatograms over the liver region using digital simulation technique to determine the hepatobiliary functions separately and to compare the rate constants obtained from the kinetic model and the results obtained from conventional liver function tests. A total of 112 cases were observed including various liver and gallbladder diseases and 8 normal subjects. Fasting patients were given intravenous injections of 300 μCi of 131 I-R.B. Hepatic uptake and excretion of radioactivity were measured for 120 minutes using a gamma camera. Two regions, one over the right lobe and the other over the gallbladder, were studied. The author applied a 3 compartment analysis to the 131 I-R.B. hepatogram. Measured 131 I-R.B. hepatogram was printed out on a line printer with curve pattern indices. Assumed rate constants and relative volume indices were placed on punch cards. Computer-aided simulation curves were printed on a line printer with curve pattern indices. The measured hepatogram and the simulated hepatogram were compared. The blood flow index (K 21 ), the hepatocellular function index (K 32 ) and the intrahepatic biliary excretion index (K 03 ) were obtained with the schematic presentation of the curves. Rate constants from the kinetic model correlated well with conventional liver function tests. In normal liver and hepatobiliary diseases, there were high statistical correlations between K 21 and Ksub(L) 131 I-R.B. Retention (%), between K 32 and Cholinesterase, and between K 03 and Alkaliphosphatase. However, there was a low statistical correlation between the results of the simulation study and the results of liver function tests in the cases of obstructive jaundice and intrahepatic cholestasis. (Evans, J.)

  7. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.

    Science.gov (United States)

    Huang, Qinghua; Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  8. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Qinghua Huang

    2018-01-01

    Full Text Available The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  9. TAO-2/SPARTE, a language-enhanced computer aided teleoperation system

    International Nuclear Information System (INIS)

    Gravez, P.; Fournier, R.

    1991-01-01

    TAO-2 is a computer system designed by CEA/DTA/UR for the remote control of nuclear servicing servomanipulators. It results from several years of research which have led to the current availability of an industrial product featuring highly advanced performances. For undersea applications, a development has also been carried out with CYBERNETIX for controlling the new hydraulic arm built by this company. An integral element of TAO-2 is the SPARTE language which deals with off-line task programming and focuses on combined manual, automatic and mixed control modes. Additionally, it takes into account the on-line part of the human operator relative to adjustment, monitoring and incident recovery. Other promising features are hybrid control specification, mechanisms for the management of external events and 'learning by touching' capabilities. The present paper describes the basic principles of TAO-2. It first recalls the fundamentals of Computer Aided Teleoperation (CAT). The functional and hardware architectures which implement the TAO-2 CAT concepts are then outlined. The next parts emphasize the original characteristics of the SPARTE control and programming language. The paper ends with a brief presentation of our approach for CAT symbolic control

  10. EEG-Based Computer Aided Diagnosis of Autism Spectrum Disorder Using Wavelet, Entropy, and ANN

    Directory of Open Access Journals (Sweden)

    Ridha Djemal

    2017-01-01

    Full Text Available Autism spectrum disorder (ASD is a type of neurodevelopmental disorder with core impairments in the social relationships, communication, imagination, or flexibility of thought and restricted repertoire of activity and interest. In this work, a new computer aided diagnosis (CAD of autism ‎based on electroencephalography (EEG signal analysis is investigated. The proposed method is based on discrete wavelet transform (DWT, entropy (En, and artificial neural network (ANN. DWT is used to decompose EEG signals into approximation and details coefficients to obtain EEG subbands. The feature vector is constructed by computing Shannon entropy values from each EEG subband. ANN classifies the corresponding EEG signal into normal or autistic based on the extracted features. The experimental results show the effectiveness of the proposed method for assisting autism diagnosis. A receiver operating characteristic (ROC curve metric is used to quantify the performance of the proposed method. The proposed method obtained promising results tested using real dataset provided by King Abdulaziz Hospital, Jeddah, Saudi Arabia.

  11. Computer-aided detection of early interstitial lung diseases using low-dose CT images

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Cheol; Kim, Soo Hyung [School of Electronics and Computer Engineering, Chonnam National University, Gwangju 500-757 (Korea, Republic of); Tan, Jun; Wang Xingwei; Lederman, Dror; Leader, Joseph K; Zheng Bin, E-mail: zhengb@upmc.edu [Department of Radiology, University of Pittsburgh, Pittsburgh, PA 15213 (United States)

    2011-02-21

    This study aims to develop a new computer-aided detection (CAD) scheme to detect early interstitial lung disease (ILD) using low-dose computed tomography (CT) examinations. The CAD scheme classifies each pixel depicted on the segmented lung areas into positive or negative groups for ILD using a mesh-grid-based region growth method and a multi-feature-based artificial neural network (ANN). A genetic algorithm was applied to select optimal image features and the ANN structure. In testing each CT examination, only pixels selected by the mesh-grid region growth method were analyzed and classified by the ANN to improve computational efficiency. All unselected pixels were classified as negative for ILD. After classifying all pixels into the positive and negative groups, CAD computed a detection score based on the ratio of the number of positive pixels to all pixels in the segmented lung areas, which indicates the likelihood of the test case being positive for ILD. When applying to an independent testing dataset of 15 positive and 15 negative cases, the CAD scheme yielded the area under receiver operating characteristic curve (AUC = 0.884 {+-} 0.064) and 80.0% sensitivity at 85.7% specificity. The results demonstrated the feasibility of applying the CAD scheme to automatically detect early ILD using low-dose CT examinations.

  12. Detection Efficiency of Microcalcification using Computer Aided Diagnosis in the Breast Ultrasonography Images

    International Nuclear Information System (INIS)

    Lee, Jin Soo; Ko, Seong Jin; Kang, Se Sik; Kim, Jung Hoon; Choi, Seok Yoon; Kim, Chang Soo; Park, Hyung Hu

    2012-01-01

    Digital Mammography makes it possible to reproduce the entire breast image. And it is used to detect microcalcification and mass which are the most important point of view of nonpalpable early breast cancer, so it has been used as the primary screening test of breast disease. It is reported that microcalcification of breast lesion is important in diagnosis of early breast cancer. In this study, six types of texture features algorithms are used to detect microcalcification on breast US images and the study has analyzed recognition rate of lesion between normal US images and other US images which microcalification is seen. As a result of the experiment, Computer aided diagnosis recognition rate that distinguishes mammography and breast US disease was considerably high 70-98%. The average contrast and entropy parameters were low in ROC analysis, but sensitivity and specificity of four types parameters were over 90%. Therefore it is possible to detect microcalcification on US images. If not only six types of texture features algorithms but also the research of additional parameter algorithm is being continually proceeded and basis of practical use on CAD is being prepared, it can be a important meaning as pre-reading. Also, it is considered very useful things for early diagnosis of breast cancer.

  13. Computer-aided-detection marker value and breast density in the detection of invasive lobular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia; Hanson, Sarah [The Elizabeth Wende Breast Clinic, Rochester, NY (United States); Roehrig, Jimmy [R2/Hologic, Inc., Santa Clara, CA (United States)

    2007-08-15

    Invasive Lobular Carcinoma (ILC) is frequently a mammographic and diagnostic dilemma; thus any additional information that CAD (Computer-Aided Detection) systems can give radiologists may be helpful. Our study was to evaluate the role of CAD numeric values as indicators of malignancy and the effect of breast density in the diagnosis of ILC. Eighty consecutive biopsy-proven ILC cases with CAD (ImageChecker {sup registered}, Hologic vertical stroke R2, Santa Clara, CA, versions 2.3, 3.1, 3.2, 5.0, 5.2) diagnosed between June 2002 and December 2004 were retrospectively reviewed. Data included: BIRADS {sup registered} breast density, whether CAD marked the cancer at diagnosis year or years prior, and lesion type. Study mammograms underwent additional CAD scans (Image Checker {sup registered} V5.3, V8.0, V8.1) to obtain a numeric value associated with each marker, low values represent increasingly suspicious features. CAD correctly marked 65% (52/80) of ILC cases, detection was found to decrease with increased breast density. Numeric values of CAD marks at sites of carcinoma showed median score of 171 (range 0 - 1121). The CAD marker may potentially be used as an additional indicator of suspicious lesion features in all breast densities and higher likelihood that an area on the mammogram requires further investigation. (orig.)

  14. Computer-aided-detection marker value and breast density in the detection of invasive lobular carcinoma

    International Nuclear Information System (INIS)

    Destounis, Stamatia; Hanson, Sarah; Roehrig, Jimmy

    2007-01-01

    Invasive Lobular Carcinoma (ILC) is frequently a mammographic and diagnostic dilemma; thus any additional information that CAD (Computer-Aided Detection) systems can give radiologists may be helpful. Our study was to evaluate the role of CAD numeric values as indicators of malignancy and the effect of breast density in the diagnosis of ILC. Eighty consecutive biopsy-proven ILC cases with CAD (ImageChecker registered , Hologic vertical stroke R2, Santa Clara, CA, versions 2.3, 3.1, 3.2, 5.0, 5.2) diagnosed between June 2002 and December 2004 were retrospectively reviewed. Data included: BIRADS registered breast density, whether CAD marked the cancer at diagnosis year or years prior, and lesion type. Study mammograms underwent additional CAD scans (Image Checker registered V5.3, V8.0, V8.1) to obtain a numeric value associated with each marker, low values represent increasingly suspicious features. CAD correctly marked 65% (52/80) of ILC cases, detection was found to decrease with increased breast density. Numeric values of CAD marks at sites of carcinoma showed median score of 171 (range 0 - 1121). The CAD marker may potentially be used as an additional indicator of suspicious lesion features in all breast densities and higher likelihood that an area on the mammogram requires further investigation. (orig.)

  15. Three-class classification in computer-aided diagnosis of breast cancer by support vector machine

    Science.gov (United States)

    Sun, Xuejun; Qian, Wei; Song, Dansheng

    2004-05-01

    Design of classifier in computer-aided diagnosis (CAD) scheme of breast cancer plays important role to its overall performance in sensitivity and specificity. Classification of a detected object as malignant lesion, benign lesion, or normal tissue on mammogram is a typical three-class pattern recognition problem. This paper presents a three-class classification approach by using two-stage classifier combined with support vector machine (SVM) learning algorithm for classification of breast cancer on mammograms. The first classification stage is used to detect abnormal areas and normal breast tissues, and the second stage is for classification of malignant or benign in detected abnormal objects. A series of spatial, morphology and texture features have been extracted on detected objects areas. By using genetic algorithm (GA), different feature groups for different stage classification have been investigated. Computerized free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) analyses have been employed in different classification stages. Results have shown that obvious performance improvement in both sensitivity and specificity was observed through proposed classification approach compared with conventional two-class classification approaches, indicating its effectiveness in classification of breast cancer on mammograms.

  16. Ratsnake: A Versatile Image Annotation Tool with Application to Computer-Aided Diagnosis

    Directory of Open Access Journals (Sweden)

    D. K. Iakovidis

    2014-01-01

    Full Text Available Image segmentation and annotation are key components of image-based medical computer-aided diagnosis (CAD systems. In this paper we present Ratsnake, a publicly available generic image annotation tool providing annotation efficiency, semantic awareness, versatility, and extensibility, features that can be exploited to transform it into an effective CAD system. In order to demonstrate this unique capability, we present its novel application for the evaluation and quantification of salient objects and structures of interest in kidney biopsy images. Accurate annotation identifying and quantifying such structures in microscopy images can provide an estimation of pathogenesis in obstructive nephropathy, which is a rather common disease with severe implication in children and infants. However a tool for detecting and quantifying the disease is not yet available. A machine learning-based approach, which utilizes prior domain knowledge and textural image features, is considered for the generation of an image force field customizing the presented tool for automatic evaluation of kidney biopsy images. The experimental evaluation of the proposed application of Ratsnake demonstrates its efficiency and effectiveness and promises its wide applicability across a variety of medical imaging domains.

  17. Individualized computer-aided education in mammography based on user modeling: concept and preliminary experiments.

    Science.gov (United States)

    Mazurowski, Maciej A; Baker, Jay A; Barnhart, Huiman X; Tourassi, Georgia D

    2010-03-01

    The authors propose the framework for an individualized adaptive computer-aided educational system in mammography that is based on user modeling. The underlying hypothesis is that user models can be developed to capture the individual error making patterns of radiologists-in-training. In this pilot study, the authors test the above hypothesis for the task of breast cancer diagnosis in mammograms. The concept of a user model was formalized as the function that relates image features to the likelihood/extent of the diagnostic error made by a radiologist-in-training and therefore to the level of difficulty that a case will pose to the radiologist-in-training (or "user"). Then, machine learning algorithms were implemented to build such user models. Specifically, the authors explored k-nearest neighbor, artificial neural networks, and multiple regression for the task of building the model using observer data collected from ten Radiology residents at Duke University Medical Center for the problem of breast mass diagnosis in mammograms. For each resident, a user-specific model was constructed that predicts the user's expected level of difficulty for each presented case based on two BI-RADS image features. In the experiments, leave-one-out data handling scheme was applied to assign each case to a low-predicted-difficulty or a high-predicted-difficulty group for each resident based on each of the three user models. To evaluate whether the user model is useful in predicting difficulty, the authors performed statistical tests using the generalized estimating equations approach to determine whether the mean actual error is the same or not between the low-predicted-difficulty group and the high-predicted-difficulty group. When the results for all observers were pulled together, the actual errors made by residents were statistically significantly higher for cases in the high-predicted-difficulty group than for cases in the low-predicted-difficulty group for all modeling

  18. Computer- Aided diagnosis system for the evaluation of chronic obstructive pulmonary disease on CT Images

    Directory of Open Access Journals (Sweden)

    Parsa Hosseini M

    2011-03-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Chronic Obstructive Pulmonary Disease (COPD is one of the most prevalent pulmonary diseases. Use of an automatic system for the detection and diagnosis of the disease will be beneficial to the patients' treatment decision-making process. In this paper, we propose a new approach for the Computer Aided Diagnosis (CAD of the disease and determination of its severity axial CT scan images."n"nMethods: In this study, 24 lung CT scans in full inspiratory and expiratory states were performed. Variations in the normalized pattern of the lungs' external parenchyma were exploited as a feature for COPD diagnosis. Subsequently, a Bayesian classifier was used to classify variations into two normal and abnormal patterns for the discrimination of patients and healthy individuals. Finally, the accuracy of the classification was assessed statistically. "n"nResults: With the proposed method, the lungs parenchymal elasticity and air-trapping were determined quantitatively. The more this feature tended to zero, the more severe air-trapping and obstructive pulmonary disease is. By analyzing CT images in the healthy and patient groups, we calculated the hard threshold for the diagnosis of the disease. Clinical results

  19. Computer-aided analysis of grain growth in metals

    DEFF Research Database (Denmark)

    Klimanek, P.; May, C.; Richter, H.

    1993-01-01

    Isothermal grain growth in aluminium, copper and alpha-iron was investigated experimentally at elevated temperatures and quantitatively interpreted by computer simulation on the base of a statistical model described in [4,5,6]. As it is demonstrated for the grain growth kinetics, the experimental...... data can be fitted satisfactorly....

  20. Computer aided taxonomy (CAT): Approach for understanding systematics of marine biota

    Digital Repository Service at National Institute of Oceanography (India)

    Chavan, V.S.; Kavlekar, D.P.; Chandramohan, D.

    Computer aided taconomy (CAT) is gaining importance day by day. In order to familiarise the taxonomy and its continuing usage an attempt has made to develop a module for knowing the systematics of organisms and to generate automatic numerical code...

  1. Computer-aided modeling framework for efficient model development, analysis and identification

    DEFF Research Database (Denmark)

    Heitzig, Martina; Sin, Gürkan; Sales Cruz, Mauricio

    2011-01-01

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy, and water. This trend is set to continue due to the substantial benefits computer-aided...... methods introduce. The key prerequisite of computer-aided product-process engineering is however the availability of models of different types, forms, and application modes. The development of the models required for the systems under investigation tends to be a challenging and time-consuming task....... The methodology has been implemented into a computer-aided modeling framework, which combines expert skills, tools, and database connections that are required for the different steps of the model development work-flow with the goal to increase the efficiency of the modeling process. The framework has two main...

  2. Application of computer-aided multi-scale modelling framework – Aerosol case study

    DEFF Research Database (Denmark)

    Heitzig, Martina; Sin, Gürkan; Glarborg, Peter

    2011-01-01

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy and water. This trend is set to continue due to the substantial benefits computer-aided...... methods provide. The key prerequisite of computer-aided product-process engineering is however the availability of models of different types, forms and application modes. The development of the models required for the systems under investigation tends to be a challenging and time-consuming task involving...... numerous steps, expert skills and different modelling tools. This motivates the development of a computer-aided modelling framework that supports the user during model development, documentation, analysis, identification, application and re-use with the goal to increase the efficiency of the modelling...

  3. Computer-Aided Diagnosis of Breast Cancer: A Multi-Center Demonstrator

    National Research Council Canada - National Science Library

    Floyd, Carey

    2000-01-01

    .... The focus has been to gather data from multiple sites in order to verify and whether the artificial neural network computer aid to the diagnosis of breast cancer can be translated between locations...

  4. APPLICATION OF COMPUTER AIDED TOMOGRAPHY (CAT) TO THE STUDY OF MARINE BENTIC COMMUNITIES

    Science.gov (United States)

    Sediment cores were imaged using a Computer-Aided Tomography (CT) scanner at Massachusetts General Hospital, Boston, Massachusetts, United States. Procedures were developed, using the attenuation of X-rays, to differentiate between sediment and the water contained in macrobenthic...

  5. Computer-aided dispatch--traffic management center field operational test : state of Utah final report

    Science.gov (United States)

    2006-07-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...

  6. Computer-aided dispatch--traffic management center field operational test : Washington State final report

    Science.gov (United States)

    2006-05-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...

  7. Computer-Aided Engineering Education at the K.U. Leuven.

    Science.gov (United States)

    Snoeys, R.; Gobin, R.

    1987-01-01

    Describes some recent initiatives and developments in the computer-aided design program in the engineering faculty of the Katholieke Universiteit Leuven (Belgium). Provides a survey of the engineering curriculum, the computer facilities, and the main software packages available. (TW)

  8. An overview of interactive computer graphics and its application to computer-aided engineering and design

    International Nuclear Information System (INIS)

    Van Dam, A.

    1983-01-01

    The purpose of this brief birds-eye view of interactive graphics is to list the key ideas, and to show how one of the most important application areas, Computer Aided Engineering/Design takes advantage of it. (orig.)

  9. Computer-Aided Detection with a Portable Electrocardiographic Recorder and Acceleration Sensors for Monitoring Obstructive Sleep Apnea

    Directory of Open Access Journals (Sweden)

    Ji-Won Baek

    2014-03-01

    Full Text Available Obstructive sleep apnea syndrome is a sleep-related breathing disorder that is caused by obstruction of the upper airway. This condition may be related with many clinical sequelae such as cardiovascular disease, high blood pressure, stroke, diabetes, and clinical depression. To diagnosis obstructive sleep apnea, in-laboratory full polysomnography is considered as a standard test to determine the severity of respiratory disturbance. However, polysomnography is expensive and complicated to perform. In this research, we explore a computer-aided diagnosis system with portable ECG equipment and tri-accelerometer (x, y, and z-axes that can automatically analyze biosignals and test for OSA. Traditional approaches to sleep apnea data analysis have been criticized; however, there are not enough suggestions to resolve the existing problems. As an effort to resolve this issue, we developed an approach to record ECG signals and abdominal movements induced by breathing by affixing ECG-enabled electrodes onto a triaxial accelerometer. With the two signals simultaneously measured, the apnea data obtained would be more accurate, relative to cases where a single signal is measured. This would be helpful in diagnosing OSA. Moreover, a useful feature point can be extracted from the two signals after applying a signal processing algorithm, and the extracted feature point can be applied in designing a computer-aided diagnosis algorithm using a machine learning technique.

  10. Progress of the Computer-Aided Engineering of Electric Drive Vehicle Batteries (CAEBAT) (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, A. A.; Han, T.; Hartridge, S.; Shaffer, C.; Kim, G. H.; Pannala, S.

    2013-06-01

    This presentation, Progress of Computer-Aided Engineering of Electric Drive Vehicle Batteries (CAEBAT) is about simulation and computer-aided engineering (CAE) tools that are widely used to speed up the research and development cycle and reduce the number of build-and-break steps, particularly in the automotive industry. Realizing this, DOE?s Vehicle Technologies Program initiated the CAEBAT project in April 2010 to develop a suite of software tools for designing batteries.

  11. Computer-Aided Prototyping Systems (CAPS) within the software acquisition process: a case study

    OpenAIRE

    Ellis, Mary Kay

    1993-01-01

    Approved for public release; distribution is unlimited This thesis provides a case study which examines the benefits derived from the practice of computer-aided prototyping within the software acquisition process. An experimental prototyping systems currently in research is the Computer Aided Prototyping System (CAPS) managed under the Computer Science department of the Naval Postgraduate School, Monterey, California. This thesis determines the qualitative value which may be realized by ...

  12. Computer-Aided Transformation of PDE Models: Languages, Representations, and a Calculus of Operations

    Science.gov (United States)

    2016-01-05

    Computer-aided transformation of PDE models: languages, representations, and a calculus of operations A domain-specific embedded language called...languages, representations, and a calculus of operations Report Title A domain-specific embedded language called ibvp was developed to model initial...Computer-aided transformation of PDE models: languages, representations, and a calculus of operations 1 Vision and background Physical and engineered systems

  13. A Computer-Aided Diagnosis System for Breast Cancer Combining Digital Mammography and Genomics

    Science.gov (United States)

    2006-05-01

    Huang, "Breast cancer diagnosis using self-organizing map for sonography." Ultrasound Med. Biol. 26, 405 (2000). 20 K. Horsch, M.L. Giger, L.A. Venta ...L.A. Venta , "Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography." Acad Radiol 11, 272 (2004). 22 W. Chen...418. 27. Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography

  14. Use of computer-aided x-ray diagnosis in oncology. [60 refs

    Energy Technology Data Exchange (ETDEWEB)

    Rotte, K H [Forschungsinstitut fuer Lungenkrankheiten und Tuberkulose, Berlin-Buch (German Democratic Republic)

    1979-01-01

    The introduction of computer-aided diagnostic reveals new perspectives for diagnostic decisions. The results of the hitherto used mathematical diagnostic models are represented. The Bayes's theorem as the most used model exhibited very different, in part unsatisfactory results. More convenient seem to be multivariate models, like discriminant analysis. Hitherto the computer-aided diagnosis was used in a relative small number of problems concerning differential diagnosis. It is necessary to compare the efficiency of the different mathematical-statistical methods.

  15. Computer-aided diagnosis of contrast-enhanced spectral mammography: A feasibility study.

    Science.gov (United States)

    Patel, Bhavika K; Ranjbar, Sara; Wu, Teresa; Pockaj, Barbara A; Li, Jing; Zhang, Nan; Lobbes, Mark; Zhang, Bin; Mitchell, J Ross

    2018-01-01

    To evaluate whether the use of a computer-aided diagnosis-contrast-enhanced spectral mammography (CAD-CESM) tool can further increase the diagnostic performance of CESM compared with that of experienced radiologists. This IRB-approved retrospective study analyzed 50 lesions described on CESM from August 2014 to December 2015. Histopathologic analyses, used as the criterion standard, revealed 24 benign and 26 malignant lesions. An expert breast radiologist manually outlined lesion boundaries on the different views. A set of morphologic and textural features were then extracted from the low-energy and recombined images. Machine-learning algorithms with feature selection were used along with statistical analysis to reduce, select, and combine features. Selected features were then used to construct a predictive model using a support vector machine (SVM) classification method in a leave-one-out-cross-validation approach. The classification performance was compared against the diagnostic predictions of 2 breast radiologists with access to the same CESM cases. Based on the SVM classification, CAD-CESM correctly identified 45 of 50 lesions in the cohort, resulting in an overall accuracy of 90%. The detection rate for the malignant group was 88% (3 false-negative cases) and 92% for the benign group (2 false-positive cases). Compared with the model, radiologist 1 had an overall accuracy of 78% and a detection rate of 92% (2 false-negative cases) for the malignant group and 62% (10 false-positive cases) for the benign group. Radiologist 2 had an overall accuracy of 86% and a detection rate of 100% for the malignant group and 71% (8 false-positive cases) for the benign group. The results of our feasibility study suggest that a CAD-CESM tool can provide complementary information to radiologists, mainly by reducing the number of false-positive findings. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Estimation of the failure risk of a maxillary premolar with different crack depths with endodontic treatment by computer-aided design/computer-aided manufacturing ceramic restorations.

    Science.gov (United States)

    Lin, Chun-Li; Chang, Yen-Hsiang; Hsieh, Shih-Kai; Chang, Wen-Jen

    2013-03-01

    This study evaluated the risk of failure for an endodontically treated premolar with different crack depths, which was shearing toward the pulp chamber and was restored by using 3 different computer-aided design/computer-aided manufacturing ceramic restoration configurations. Three 3-dimensional finite element models designed with computer-aided design/computer-aided manufacturing ceramic onlay, endocrown, and conventional crown restorations were constructed to perform simulations. The Weibull function was incorporated with finite element analysis to calculate the long-term failure probability relative to different load conditions. The results indicated that the stress values on the enamel, dentin, and luting cement for endocrown restorations exhibited the lowest values relative to the other 2 restoration methods. Weibull analysis revealed that the overall failure probabilities in a shallow cracked premolar were 27%, 2%, and 1% for the onlay, endocrown, and conventional crown restorations, respectively, in the normal occlusal condition. The corresponding values were 70%, 10%, and 2% for the depth cracked premolar. This numeric investigation suggests that the endocrown provides sufficient fracture resistance only in a shallow cracked premolar with endodontic treatment. The conventional crown treatment can immobilize the premolar for different cracked depths with lower failure risk. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    Science.gov (United States)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  18. Machine learning techniques for breast cancer computer aided diagnosis using different image modalities: A systematic review.

    Science.gov (United States)

    Yassin, Nisreen I R; Omran, Shaimaa; El Houby, Enas M F; Allam, Hemat

    2018-03-01

    The high incidence of breast cancer in women has increased significantly in the recent years. Physician experience of diagnosing and detecting breast cancer can be assisted by using some computerized features extraction and classification algorithms. This paper presents the conduction and results of a systematic review (SR) that aims to investigate the state of the art regarding the computer aided diagnosis/detection (CAD) systems for breast cancer. The SR was conducted using a comprehensive selection of scientific databases as reference sources, allowing access to diverse publications in the field. The scientific databases used are Springer Link (SL), Science Direct (SD), IEEE Xplore Digital Library, and PubMed. Inclusion and exclusion criteria were defined and applied to each retrieved work to select those of interest. From 320 studies retrieved, 154 studies were included. However, the scope of this research is limited to scientific and academic works and excludes commercial interests. This survey provides a general analysis of the current status of CAD systems according to the used image modalities and the machine learning based classifiers. Potential research studies have been discussed to create a more objective and efficient CAD systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development of computer-aided design and production system for nuclear power plant

    International Nuclear Information System (INIS)

    Ishii, Masanori

    1983-01-01

    The technically required matters related to the design and production of nuclear power stations tended to increase from the viewpoint of the safety and reliability, and it is indispensable to cope with such technically required matters skillfully for the rationalization of the design and production and for the construction of highly reliable plants. Ishikawajima Harima Heavy Industries Co., Ltd., has developed the computer-aided design data information and engineering system which performs dialogue type design and drawing, and as the result, the design-production consistent system is developed to do stress analysis, production design, production management and the output of data for numerically controlled machine tools consistently. In this paper, mainly the consistent system in the field of plant design centering around piping and also the computer system for the design of vessels and others are outlined. The features of the design works for nuclear power plants, the rationalization of the design and production management of piping and vessels, and the application of the CAD system to other general equipment and improvement works are reported. This system is the powerful means to meet the requirement of heightening quality and reducing cost. (Kako, I.)

  20. Chawton Novels Online, Women’s Writing 1751-1834 and Computer-Aided Textual Analysis

    Directory of Open Access Journals (Sweden)

    Anne Bandry-Scubbi

    2015-10-01

    Full Text Available Using Chawton House Library’s “Novels Online,” several corpora have been set up for a computer-aided textual analysis of the use of vocabulary by women writing “domestic novels” from 1752 to 1834. This corpus stylistics approach makes it possible to map texts according to their word usage and to identify quantitative keywords which provide vocabulary profiles through comparison and contrast with contemporary male and female canonical texts. Items identified include pronouns, markers of dialogue and of intensity; others can be grouped into specific lexical fields such as feelings. One text from the collection then forms the object of a case-study to explore a paradox: although Jane Taylor’s use of vocabulary in her 1817 Rachel appears the most representative of the corpus made up of 42 novels by women, this Chawton text has been called “a highly original tale.” Methodology and findings are both presented to address the challenge of identifying features which constitute typicality.

  1. Progress in computer aided diagnosis for medical images by information technology

    International Nuclear Information System (INIS)

    Mekada, Yoshito

    2007-01-01

    This paper describes the history, present state and future view of computer aided diagnosis (CAD) based on processing, recognition and visualization of chest and abdominal images. A primitive feature of CAD is seen as early as in 1960's for lung cancer detection. Contemporarily, advances in medical imaging by CT, MRI, single photon emission computed tomography (SPECT) and positron emission tomography (PET) in multi-dimensions require doctors to read those vast information, where necessity of CAD is evident. At present, simultaneous CAD for multi-organs and multi-diseases is in progress, the interaction between images and medical doctors is leading to developing a newer system like virtual endoscopy, objective evaluation of CAD systems is necessary for its approval to authorities like fluorescein diacetate (FDA) with use of receiver operating characteristics analysis, and thus cooperation of medical and technological fields is more and more important. In future, CAD should be responsible for individual difference and for change in disease state, usable simultaneously for time and space, more recognized of its importance by doctors, and more useful in participation to therapeutic practice. (R.T.)

  2. Computer-Aided Diagnosis of Different Rotator Cuff Lesions Using Shoulder Musculoskeletal Ultrasound.

    Science.gov (United States)

    Chang, Ruey-Feng; Lee, Chung-Chien; Lo, Chung-Ming

    2016-09-01

    The lifetime prevalence of shoulder pain approaches 70%, which is mostly attributable to rotator cuff lesions such as inflammation, calcific tendinitis and tears. On clinical examination, shoulder ultrasound is recommended for the detection of lesions. However, there exists inter-operator variability in diagnostic accuracy because of differences in the experience and expertise of operators. In this study, a computer-aided diagnosis (CAD) system was developed to assist ultrasound operators in diagnosing rotator cuff lesions and to improve the practicality of ultrasound examination. The collected cases included 43 cases of inflammation, 30 cases of calcific tendinitis and 26 tears. For each case, the lesion area and texture features were extracted from the entire lesions and combined in a multinomial logistic regression classifier for lesion classification. The proposed CAD achieved an accuracy of 87.9%. The individual accuracy of this CAD system was 88.4% for inflammation, 83.3% for calcific tendinitis and 92.3% for tears. Cohen's k was 0.798. On the basis of its diagnostic performance, clinical use of this CAD technique has promise. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Computer aided analysis of prostate histopathology images to support a refined Gleason grading system

    Science.gov (United States)

    Ren, Jian; Sadimin, Evita; Foran, David J.; Qi, Xin

    2017-02-01

    The Gleason grading system used to render prostate cancer diagnosis has recently been updated to allow more accurate grade stratification and higher prognostic discrimination when compared to the traditional grading system. In spite of progress made in trying to standardize the grading process, there still remains approximately a 30% grading discrepancy between the score rendered by general pathologists and those provided by experts while reviewing needle biopsies for Gleason pattern 3 and 4, which accounts for more than 70% of daily prostate tis- sue slides at most institutions. We propose a new computational imaging method for Gleason pattern 3 and 4 classification, which better matches the newly established prostate cancer grading system. The computer- aided analysis method includes two phases. First, the boundary of each glandular region is automatically segmented using a deep convolutional neural network. Second, color, shape and texture features are extracted from superpixels corresponding to the outer and inner glandular regions and are subsequently forwarded to a random forest classifier to give a gradient score between 3 and 4 for each delineated glandular region. The F1 score for glandular segmentation is 0.8460 and the classification accuracy is 0.83+/-0.03.

  4. Computer-aided detection of early cancer in the esophagus using HD endoscopy images

    Science.gov (United States)

    van der Sommen, Fons; Zinger, Svitlana; Schoon, Erik J.; de With, Peter H. N.

    2013-02-01

    Esophageal cancer is the fastest rising type of cancer in the Western world. The recent development of High-Definition (HD) endoscopy has enabled the specialist physician to identify cancer at an early stage. Nevertheless, it still requires considerable effort and training to be able to recognize these irregularities associated with early cancer. As a first step towards a Computer-Aided Detection (CAD) system that supports the physician in finding these early stages of cancer, we propose an algorithm that is able to identify irregularities in the esophagus automatically, based on HD endoscopic images. The concept employs tile-based processing, so our system is not only able to identify that an endoscopic image contains early cancer, but it can also locate it. The identification is based on the following steps: (1) preprocessing, (2) feature extraction with dimensionality reduction, (3) classification. We evaluate the detection performance in RGB, HSI and YCbCr color space using the Color Histogram (CH) and Gabor features and we compare with other well-known features to describe texture. For classification, we employ a Support Vector Machine (SVM) and evaluate its performance using different parameters and kernel functions. In experiments, our system achieves a classification accuracy of 95.9% on 50×50 pixel tiles of tumorous and normal tissue and reaches an Area Under the Curve (AUC) of 0.990. In 22 clinical examples our algorithm was able to identify all (pre-)cancerous regions and annotate those regions reasonably well. The experimental and clinical validation are considered promising for a CAD system that supports the physician in finding early stage cancer.

  5. Computer-aided assessment of regional abdominal fat with food residue removal in CT.

    Science.gov (United States)

    Makrogiannis, Sokratis; Caturegli, Giorgio; Davatzikos, Christos; Ferrucci, Luigi

    2013-11-01

    Separate quantification of abdominal subcutaneous and visceral fat regions is essential to understand the role of regional adiposity as risk factor in epidemiological studies. Fat quantification is often based on computed tomography (CT) because fat density is distinct from other tissue densities in the abdomen. However, the presence of intestinal food residues with densities similar to fat may reduce fat quantification accuracy. We introduce an abdominal fat quantification method in CT with interest in food residue removal. Total fat was identified in the feature space of Hounsfield units and divided into subcutaneous and visceral components using model-based segmentation. Regions of food residues were identified and removed from visceral fat using a machine learning method integrating intensity, texture, and spatial information. Cost-weighting and bagging techniques were investigated to address class imbalance. We validated our automated food residue removal technique against semimanual quantifications. Our feature selection experiments indicated that joint intensity and texture features produce the highest classification accuracy at 95%. We explored generalization capability using k-fold cross-validation and receiver operating characteristic (ROC) analysis with variable k. Losses in accuracy and area under ROC curve between maximum and minimum k were limited to 0.1% and 0.3%. We validated tissue segmentation against reference semimanual delineations. The Dice similarity scores were as high as 93.1 for subcutaneous fat and 85.6 for visceral fat. Computer-aided regional abdominal fat quantification is a reliable computational tool for large-scale epidemiological studies. Our proposed intestinal food residue reduction scheme is an original contribution of this work. Validation experiments indicate very good accuracy and generalization capability. Published by Elsevier Inc.

  6. Computer aided detection of brain micro-bleeds in traumatic brain injury

    Science.gov (United States)

    van den Heuvel, T. L. A.; Ghafoorian, M.; van der Eerden, A. W.; Goraj, B. M.; Andriessen, T. M. J. C.; ter Haar Romeny, B. M.; Platel, B.

    2015-03-01

    Brain micro-bleeds (BMBs) are used as surrogate markers for detecting diffuse axonal injury in traumatic brain injury (TBI) patients. The location and number of BMBs have been shown to influence the long-term outcome of TBI. To further study the importance of BMBs for prognosis, accurate localization and quantification are required. The task of annotating BMBs is laborious, complex and prone to error, resulting in a high inter- and intra-reader variability. In this paper we propose a computer-aided detection (CAD) system to automatically detect BMBs in MRI scans of moderate to severe neuro-trauma patients. Our method consists of four steps. Step one: preprocessing of the data. Both susceptibility (SWI) and T1 weighted MRI scans are used. The images are co-registered, a brain-mask is generated, the bias field is corrected, and the image intensities are normalized. Step two: initial candidates for BMBs are selected as local minima in the processed SWI scans. Step three: feature extraction. BMBs appear as round or ovoid signal hypo-intensities on SWI. Twelve features are computed to capture these properties of a BMB. Step four: Classification. To identify BMBs from the set of local minima using their features, different classifiers are trained on a database of 33 expert annotated scans and 18 healthy subjects with no BMBs. Our system uses a leave-one-out strategy to analyze its performance. With a sensitivity of 90% and 1.3 false positives per BMB, our CAD system shows superior results compared to state-of-the-art BMB detection algorithms (developed for non-trauma patients).

  7. Direct laser sintering of metal powders: Mechanism, kinetics and microstructural features

    International Nuclear Information System (INIS)

    Simchi, A.

    2006-01-01

    In the present work, the densification and microstructural evolution during direct laser sintering of metal powders were studied. Various ferrous powders including Fe, Fe-C, Fe-Cu, Fe-C-Cu-P, 316L stainless steel, and M2 high-speed steel were used. The empirical sintering rate data was related to the energy input of the laser beam according to the first order kinetics equation to establish a simple sintering model. The equation calculates the densification of metal powders during direct laser sintering process as a function of operating parameters including laser power, scan rate, layer thickness and scan line spacing. It was found that when melting/solidification approach is the mechanism of sintering, the densification of metals powders (D) can be expressed as an exponential function of laser specific energy input (ψ) as ln(1 - D) = -Kψ. The coefficient K is designated as 'densification coefficient'; a material dependent parameter that varies with chemical composition, powder particle size, and oxygen content of the powder material. The mechanism of particle bonding and microstructural features of the laser sintered powders are addressed

  8. Multiparametric computer-aided differential diagnosis of Alzheimer's disease and frontotemporal dementia using structural and advanced MRI

    International Nuclear Information System (INIS)

    Bron, Esther E.; Klein, Stefan; Smits, Marion; Steketee, Rebecca M.E.; Meijboom, Rozanna; Papma, Janne M.; Swieten, John C. van; Groot, Marius de; Niessen, Wiro J.

    2017-01-01

    To investigate the added diagnostic value of arterial spin labelling (ASL) and diffusion tensor imaging (DTI) to structural MRI for computer-aided classification of Alzheimer's disease (AD), frontotemporal dementia (FTD), and controls. This retrospective study used MRI data from 24 early-onset AD and 33 early-onset FTD patients and 34 controls (CN). Classification was based on voxel-wise feature maps derived from structural MRI, ASL, and DTI. Support vector machines (SVMs) were trained to classify AD versus CN (AD-CN), FTD-CN, AD-FTD, and AD-FTD-CN (multi-class). Classification performance was assessed by the area under the receiver-operating-characteristic curve (AUC) and accuracy. Using SVM significance maps, we analysed contributions of brain regions. Combining ASL and DTI with structural MRI resulted in higher classification performance for differential diagnosis of AD and FTD (AUC = 84%; p = 0.05) than using structural MRI by itself (AUC = 72%). The performance of ASL and DTI themselves did not improve over structural MRI. The classifications were driven by different brain regions for ASL and DTI than for structural MRI, suggesting complementary information. ASL and DTI are promising additions to structural MRI for classification of early-onset AD, early-onset FTD, and controls, and may improve the computer-aided differential diagnosis on a single-subject level. (orig.)

  9. Multiparametric computer-aided differential diagnosis of Alzheimer's disease and frontotemporal dementia using structural and advanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Bron, Esther E.; Klein, Stefan [Erasmus MC, Biomedical Imaging Group Rotterdam, Departments of Medical Informatics and Radiology and Nuclear Medicine, Office Na2502, P.O. Box 2040, Rotterdam (Netherlands); Smits, Marion; Steketee, Rebecca M.E.; Meijboom, Rozanna [Erasmus MC, Department of Radiology and Nuclear Medicine, Rotterdam (Netherlands); Papma, Janne M.; Swieten, John C. van [Erasmus MC, Department of Neurology, Rotterdam (Netherlands); Groot, Marius de [Erasmus MC, Biomedical Imaging Group Rotterdam, Departments of Medical Informatics and Radiology and Nuclear Medicine, Office Na2502, P.O. Box 2040, Rotterdam (Netherlands); Erasmus MC, Department of Epidemiology, Rotterdam (Netherlands); Niessen, Wiro J. [Erasmus MC, Biomedical Imaging Group Rotterdam, Departments of Medical Informatics and Radiology and Nuclear Medicine, Office Na2502, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Imaging Physics, Applied Sciences, Delft (Netherlands)

    2017-08-15

    To investigate the added diagnostic value of arterial spin labelling (ASL) and diffusion tensor imaging (DTI) to structural MRI for computer-aided classification of Alzheimer's disease (AD), frontotemporal dementia (FTD), and controls. This retrospective study used MRI data from 24 early-onset AD and 33 early-onset FTD patients and 34 controls (CN). Classification was based on voxel-wise feature maps derived from structural MRI, ASL, and DTI. Support vector machines (SVMs) were trained to classify AD versus CN (AD-CN), FTD-CN, AD-FTD, and AD-FTD-CN (multi-class). Classification performance was assessed by the area under the receiver-operating-characteristic curve (AUC) and accuracy. Using SVM significance maps, we analysed contributions of brain regions. Combining ASL and DTI with structural MRI resulted in higher classification performance for differential diagnosis of AD and FTD (AUC = 84%; p = 0.05) than using structural MRI by itself (AUC = 72%). The performance of ASL and DTI themselves did not improve over structural MRI. The classifications were driven by different brain regions for ASL and DTI than for structural MRI, suggesting complementary information. ASL and DTI are promising additions to structural MRI for classification of early-onset AD, early-onset FTD, and controls, and may improve the computer-aided differential diagnosis on a single-subject level. (orig.)

  10. Computer aided detection of masses in mammography using subregion Hotelling observers

    International Nuclear Information System (INIS)

    Baydush, Alan H.; Catarious, David M.; Abbey, Craig K.; Floyd, Carey E.

    2003-01-01

    We propose to investigate the use of the subregion Hotelling observer for the basis of a computer aided detection scheme for masses in mammography. A database of 1320 regions of interest (ROIs) was selected from the DDSM database collected by the University of South Florida using the Lumisys scanner cases. The breakdown of the cases was as follows: 656 normal ROIs, 307 benign ROIs, and 357 cancer ROIs. Each ROI was extracted at a size of 1024x1024 pixels and subsampled to 128x128 pixels. For the detection task, cancer and benign cases were considered positive and normal was considered negative. All positive cases had the lesion centered in the ROI. We chose to investigate the subregion Hotelling observer as a classifier to detect masses. The Hotelling observer incorporates information about the signal, the background, and the noise correlation for prediction of positive and negative and is the optimal detector when these are known. For our study, 225 subregion Hotelling observers were set up in a 15x15 grid across the center of the ROIs. Each separate observer was designed to 'observe', or discriminate, an 8x8 pixel area of the image. A leave one out training and testing methodology was used to generate 225 'features', where each feature is the output of the individual observers. The 225 features derived from separate Hotelling observers were then narrowed down by using forward searching linear discriminants (LDs). The reduced set of features was then analyzed using an additional LD with receiver operating characteristic (ROC) analysis. The 225 Hotelling observer features were searched by the forward searching LD, which selected a subset of 37 features. This subset of 37 features was then analyzed using an additional LD, which gave a ROC area under the curve of 0.9412+/-0.006 and a partial area of 0.6728. Additionally, at 98% sensitivity the overall classifier had a specificity of 55.9% and a positive predictive value of 69.3%. Preliminary results suggest that

  11. Computer-aided classification of lung nodules on computed tomography images via deep learning technique

    Directory of Open Access Journals (Sweden)

    Hua KL

    2015-08-01

    Full Text Available Kai-Lung Hua,1 Che-Hao Hsu,1 Shintami Chusnul Hidayati,1 Wen-Huang Cheng,2 Yu-Jen Chen3 1Department of Computer Science and Information Engineering, National Taiwan University of Science and Technology, 2Research Center for Information Technology Innovation, Academia Sinica, 3Department of Radiation Oncology, MacKay Memorial Hospital, Taipei, Taiwan Abstract: Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain. Keywords: nodule classification, deep learning, deep belief network, convolutional neural network

  12. Computer Aided Theragnosis Using Quantitative Ultrasound Spectroscopy and Maximum Mean Discrepancy in Locally Advanced Breast Cancer.

    Science.gov (United States)

    Gangeh, Mehrdad J; Tadayyon, Hadi; Sannachi, Lakshmanan; Sadeghi-Naini, Ali; Tran, William T; Czarnota, Gregory J

    2016-03-01

    A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic methods in conjunction with advanced machine learning techniques. Specifically, a kernel-based metric named maximum mean discrepancy (MMD), a technique for learning from imbalanced data based on random undersampling, and supervised learning were investigated with response-monitoring data from LABC patients. The CAT system was tested on 56 patients using statistical significance tests and leave-one-subject-out classification techniques. Textural features using state-of-the-art local binary patterns (LBP), and gray-scale intensity features were extracted from the spectral parametric maps in the proposed CAT system. The system indicated significant differences in changes between the responding and non-responding patient populations as well as high accuracy, sensitivity, and specificity in discriminating between the two patient groups early after the start of treatment, i.e., on weeks 1 and 4 of several months of treatment. The proposed CAT system achieved an accuracy of 85%, 87%, and 90% on weeks 1, 4 and 8, respectively. The sensitivity and specificity of developed CAT system for the same times was 85%, 95%, 90% and 85%, 85%, 91%, respectively. The proposed CAT system thus establishes a noninvasive framework for monitoring cancer treatment response in tumors using clinical ultrasound imaging in conjunction with machine learning techniques. Such a framework can potentially facilitate the detection of refractory responses in patients to treatment early on during a course of therapy to enable possibly switching to more efficacious treatments.

  13. The Application of Computer-Aided Discovery to Spacecraft Site Selection

    Science.gov (United States)

    Pankratius, V.; Blair, D. M.; Gowanlock, M.; Herring, T.

    2015-12-01

    The selection of landing and exploration sites for interplanetary robotic or human missions is a complex task. Historically it has been labor-intensive, with large groups of scientists manually interpreting a planetary surface across a variety of datasets to identify potential sites based on science and engineering constraints. This search process can be lengthy, and excellent sites may get overlooked when the aggregate value of site selection criteria is non-obvious or non-intuitive. As planetary data collection leads to Big Data repositories and a growing set of selection criteria, scientists will face a combinatorial search space explosion that requires scalable, automated assistance. We are currently exploring more general computer-aided discovery techniques in the context of planetary surface deformation phenomena that can lend themselves to application in the landing site search problem. In particular, we are developing a general software framework that addresses key difficulties: characterizing a given phenomenon or site based on data gathered from multiple instruments (e.g. radar interferometry, gravity, thermal maps, or GPS time series), and examining a variety of possible workflows whose individual configurations are optimized to isolate different features. The framework allows algorithmic pipelines and hypothesized models to be perturbed or permuted automatically within well-defined bounds established by the scientist. For example, even simple choices for outlier and noise handling or data interpolation can drastically affect the detectability of certain features. These techniques aim to automate repetitive tasks that scientists routinely perform in exploratory analysis, and make them more efficient and scalable by executing them in parallel in the cloud. We also explore ways in which machine learning can be combined with human feedback to prune the search space and converge to desirable results. Acknowledgements: We acknowledge support from NASA AIST

  14. Computer-aided diagnosis of periapical cyst and keratocystic odontogenic tumor on cone beam computed tomography.

    Science.gov (United States)

    Yilmaz, E; Kayikcioglu, T; Kayipmaz, S

    2017-07-01

    the new dataset selected for this study. The studies mentioned in this article, along with the selected 3D dataset, 3D statistics calculated from the dataset, and performance results of the different classifiers, comprise an important contribution to the field of computer-aided diagnosis of dental apical lesions. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. The Impact of Machine Translation and Computer-aided Translation on Translators

    Science.gov (United States)

    Peng, Hao

    2018-03-01

    Under the context of globalization, communications between countries and cultures are becoming increasingly frequent, which make it imperative to use some techniques to help translate. This paper is to explore the influence of computer-aided translation on translators, which is derived from the field of the computer-aided translation (CAT) and machine translation (MT). Followed by an introduction to the development of machine and computer-aided translation, it then depicts the technologies practicable to translators, which are trying to analyze the demand of designing the computer-aided translation so far in translation practice, and optimize the designation of computer-aided translation techniques, and analyze its operability in translation. The findings underline the advantages and disadvantages of MT and CAT tools, and the serviceability and future development of MT and CAT technologies. Finally, this thesis probes into the impact of these new technologies on translators in hope that more translators and translation researchers can learn to use such tools to improve their productivity.

  16. Artificial intelligence programming languages for computer aided manufacturing

    Science.gov (United States)

    Rieger, C.; Samet, H.; Rosenberg, J.

    1979-01-01

    Eight Artificial Intelligence programming languages (SAIL, LISP, MICROPLANNER, CONNIVER, MLISP, POP-2, AL, and QLISP) are presented and surveyed, with examples of their use in an automated shop environment. Control structures are compared, and distinctive features of each language are highlighted. A simple programming task is used to illustrate programs in SAIL, LISP, MICROPLANNER, and CONNIVER. The report assumes reader knowledge of programming concepts, but not necessarily of the languages surveyed.

  17. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    Science.gov (United States)

    2008-06-01

    of unknown pathology , all other ROIs generated from that specific subject’s reconstructed volumes were excluded from the KB. For scheme B, all the FPs...query ROI of unknown pathology , all other ROIs generated from that specific subject’s reconstructed volumes were excluded from the KB. For scheme B...Qian, L. Li, and L.P. Clarke, "Image feature extraction for mass detection in digital mammography: Influence of wavelet analysis." Med. Phys. 26

  18. Computer-Aided Chemical Product Design Framework: Design of High Performance and Environmentally Friendly Refrigerants

    DEFF Research Database (Denmark)

    Cignitti, Stefano; Zhang, Lei; Gani, Rafiqul

    properties and needs should carefully be selected for a given heat pump cycle to ensure that an optimum refrigerant is found? How can cycle performance and environmental criteria be integrated at the product design stage and not in post-design analysis? Computer-aided product design methods enable...... the possibility of designing novel molecules, mixtures and blends, such as refrigerants through a systematic framework (Cignitti et al., 2015; Yunus et al., 2014). In this presentation a computer-aided framework is presented for chemical product design through mathematical optimization. Here, molecules, mixtures...... and blends, are systematically designed through a decomposition based solution method. Given a problem definition, computer-aided molecular design (CAMD) problem is defined, which is formulated into a mixed integer nonlinear program (MINLP). The decomposed solution method then sequentially divides the MINLP...

  19. A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.

    Science.gov (United States)

    Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus

    2016-11-01

    Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.

  20. [Computer aided design for fixed partial denture framework based on reverse engineering technology].

    Science.gov (United States)

    Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2006-03-01

    To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.

  1. The Research of Computer Aided Farm Machinery Designing Method Based on Ergonomics

    Science.gov (United States)

    Gao, Xiyin; Li, Xinling; Song, Qiang; Zheng, Ying

    Along with agricultural economy development, the farm machinery product type Increases gradually, the ergonomics question is also getting more and more prominent. The widespread application of computer aided machinery design makes it possible that farm machinery design is intuitive, flexible and convenient. At present, because the developed computer aided ergonomics software has not suitable human body database, which is needed in view of farm machinery design in China, the farm machinery design have deviation in ergonomics analysis. This article puts forward that using the open database interface procedure in CATIA to establish human body database which aims at the farm machinery design, and reading the human body data to ergonomics module of CATIA can product practical application virtual body, using human posture analysis and human activity analysis module to analysis the ergonomics in farm machinery, thus computer aided farm machinery designing method based on engineering can be realized.

  2. Computer-aided system for interactive psychomotor testing

    Science.gov (United States)

    Selivanova, Karina G.; Ignashchuk, Olena V.; Koval, Leonid G.; Kilivnik, Volodymyr S.; Zlepko, Alexandra S.; Sawicki, Daniel; Kalizhanova, Aliya; Zhanpeisova, Aizhan; Smailova, Saule

    2017-08-01

    Nowadays research of psychomotor actions has taken a special place in education, sports, medicine, psychology etc. Development of computer system for psychomotor testing could help solve many operational problems in psychoneurology and psychophysiology and also determine the individual characteristics of fine motor skills. This is particularly relevant issue when it comes to children, students, athletes for definition of personal and professional features. The article presents the dynamics of a developing psychomotor skills and application in the training process of means. The results of testing indicated their significant impact on psychomotor skills development.

  3. Computer-aided fiber analysis for crime scene forensics

    Science.gov (United States)

    Hildebrandt, Mario; Arndt, Christian; Makrushin, Andrey; Dittmann, Jana

    2012-03-01

    The forensic analysis of fibers is currently completely manual and therefore time consuming. The automation of analysis steps can significantly support forensic experts and reduce the time, required for the investigation. Moreover, a subjective expert belief is extended by objective machine estimation. This work proposes the pattern recognition pipeline containing the digital acquisition of a fiber media, the pre-processing for fiber segmentation, and the extraction of the distinctive characteristics of fibers. Currently, basic geometrical features like width, height, area of optically dominant fibers are investigated. In order to support the automatic classification of fibers, supervised machine learning algorithms are evaluated. The experimental setup includes a car seat and two pieces clothing of a different fabric. As preliminary work, acrylic as synthetic and sheep wool as natural fiber are chosen to be classified. While sitting on the seat, a test person leaves textile fibers. The test aims at automatic distinguishing of clothes through the fiber traces gained from the seat with the help of adhesive tape. The digitalization of fiber samples is provided by a contactless chromatic white light sensor. First test results showed, that two optically very different fibers can be properly assigned to their corresponding fiber type. The best classifier achieves an accuracy of 75 percent correctly classified samples for our suggested features.

  4. Energy-aware memory management for embedded multimedia systems a computer-aided design approach

    CERN Document Server

    Balasa, Florin

    2011-01-01

    Energy-Aware Memory Management for Embedded Multimedia Systems: A Computer-Aided Design Approach presents recent computer-aided design (CAD) ideas that address memory management tasks, particularly the optimization of energy consumption in the memory subsystem. It explains how to efficiently implement CAD solutions, including theoretical methods and novel algorithms. The book covers various energy-aware design techniques, including data-dependence analysis techniques, memory size estimation methods, extensions of mapping approaches, and memory banking approaches. It shows how these techniques

  5. Computer-aided diagnosis of pneumoconiosis abnormalities extracted from chest radiographs scanned with a CCD scanner

    International Nuclear Information System (INIS)

    Abe, Koji; Minami, Masahide; Nakamura, Munehiro

    2011-01-01

    This paper presents a computer-aided diagnosis for pneumoconiosis radiographs obtained with a common charge-coupled devices (CCD) scanner. Since the current computer-aided diagnosis systems of pneumoconiosis are not practical for medical doctors due to high costs of usage for a special scanner, we propose a novel system which measures abnormalities of pneumoconiosis from lung images obtained with a common CCD scanner. Experimental results of discriminations between normal and abnormal cases for 56 right-lung images including 6 standard pneumoconiosis images have shown that the proposed abnormalities are well extracted according to the standards of pneumoconiosis categories. (author)

  6. Computer aided molecular design with combined molecular modeling and group contribution

    DEFF Research Database (Denmark)

    Harper, Peter Mathias; Gani, Rafiqul; Kolar, Petr

    1999-01-01

    Computer-aided molecular design (CAMD) provides a means for determining molecules or mixtures of molecules (CAMMD) having a desirable set of physicochemical properties. The application range of CAMD is restricted due to limitations on the complexity of the generated molecular structures and on th......Computer-aided molecular design (CAMD) provides a means for determining molecules or mixtures of molecules (CAMMD) having a desirable set of physicochemical properties. The application range of CAMD is restricted due to limitations on the complexity of the generated molecular structures...

  7. A Multi-step and Multi-level approach for Computer Aided Molecular Design

    DEFF Research Database (Denmark)

    . The problem formulation step incorporates a knowledge base for the identification and setup of the design criteria. Candidate compounds are identified using a multi-level generate and test CAMD solution algorithm capable of designing molecules having a high level of molecular detail. A post solution step...... using an Integrated Computer Aided System (ICAS) for result analysis and verification is included in the methodology. Keywords: CAMD, separation processes, knowledge base, molecular design, solvent selection, substitution, group contribution, property prediction, ICAS Introduction The use of Computer...... Aided Molecular Design (CAMD) for the identification of compounds having specific physic...

  8. A Computer-Aided Diagnosis System for Breast Cancer Combining Mammography and Proteomics

    Science.gov (United States)

    2007-05-01

    for sonography,” Ultrasound Med. Biol. 26, 405-411 2000. 20K. Horsch, M. L. Giger, L. A. Venta , and C. J. Vyborny, “Computerized diagnosis of breast...lesions on ultrasound,” Med. Phys. 29, 157-164 2002. 21K. Horsch, M. L. Giger, C. J. Vyborny, and L. A. Venta , “Performance of computer-aided...Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography. Acad Radiol

  9. Article Commentary: Computer-Aided Detection of Breast Cancer — Have All Bases Been Covered?

    Directory of Open Access Journals (Sweden)

    Gautam S. Muralidhar

    2008-01-01

    Full Text Available The use of computer-aided detection (CAD systems in mammography has been the subject of intense research for many years. These systems have been developed with the aim of helping radiologists to detect signs of breast cancer. However, the effectiveness of CAD systems in practice has sparked recent debate. In this commentary, we argue that computer-aided detection will become an increasingly important tool for radiologists in the early detection of breast cancer, but there are some important issues that need to be given greater focus in designing CAD systems if they are to reach their full potential.

  10. Features of the kinetics of heterogeneous reactions with phase transformations on catalyst surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Berman, A D; Krylov, O V

    1978-01-01

    This paper presents a review of 41 bibliographic references to experiments on the adsorption of various gases (e.g., carbon monoxide, formic acid, ammonia, and oxygen) on metals (e.g., nickel, molybdenum, and platinum) and oxides covers observations of two-dimensional phases during adsorption; the kinetics of adsorption and catalysis associated with two-dimensional phase transitions; and several approximate models for describing the kinetics of heterogeneous catalysis which account for two-dimensional phase transformations on catalyst surfaces.

  11. The Development of Computer-Aided Design for Electrical Equipment Selection and Arrangement of 10 Kv Switchgear

    Directory of Open Access Journals (Sweden)

    Chernaya Anastassiya

    2015-01-01

    Full Text Available The paper intends to give an overview of a computer-aided design program application. The research includes two main parts: the development of a computer-aided design for an appropriate switchgear selection and its arrangement in an indoor switchgear layout. Matlab program was used to develop a computer-aided design system. The use of this program considerably simplifies the selection and arrangement of 10 kV switchgear.

  12. Computer-aided detection of masses in digital tomosynthesis mammography: Comparison of three approaches

    International Nuclear Information System (INIS)

    Chan Heangping; Wei Jun; Zhang Yiheng; Helvie, Mark A.; Moore, Richard H.; Sahiner, Berkman; Hadjiiski, Lubomir; Kopans, Daniel B.

    2008-01-01

    The authors are developing a computer-aided detection (CAD) system for masses on digital breast tomosynthesis mammograms (DBT). Three approaches were evaluated in this study. In the first approach, mass candidate identification and feature analysis are performed in the reconstructed three-dimensional (3D) DBT volume. A mass likelihood score is estimated for each mass candidate using a linear discriminant analysis (LDA) classifier. Mass detection is determined by a decision threshold applied to the mass likelihood score. A free response receiver operating characteristic (FROC) curve that describes the detection sensitivity as a function of the number of false positives (FPs) per breast is generated by varying the decision threshold over a range. In the second approach, prescreening of mass candidate and feature analysis are first performed on the individual two-dimensional (2D) projection view (PV) images. A mass likelihood score is estimated for each mass candidate using an LDA classifier trained for the 2D features. The mass likelihood images derived from the PVs are backprojected to the breast volume to estimate the 3D spatial distribution of the mass likelihood scores. The FROC curve for mass detection can again be generated by varying the decision threshold on the 3D mass likelihood scores merged by backprojection. In the third approach, the mass likelihood scores estimated by the 3D and 2D approaches, described above, at the corresponding 3D location are combined and evaluated using FROC analysis. A data set of 100 DBT cases acquired with a GE prototype system at the Breast Imaging Laboratory in the Massachusetts General Hospital was used for comparison of the three approaches. The LDA classifiers with stepwise feature selection were designed with leave-one-case-out resampling. In FROC analysis, the CAD system for detection in the DBT volume alone achieved test sensitivities of 80% and 90% at average FP rates of 1.94 and 3.40 per breast, respectively. With the

  13. Computer-aided detection of bladder wall thickening in CT urography (CTU)

    Science.gov (United States)

    Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon Z.; Gordon, Marshall N.; Samala, Ravi K.

    2018-02-01

    We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). Bladder wall thickening is a manifestation of bladder cancer and its detection is more challenging than the detection of bladder masses. We first segmented the inner and outer bladder walls using our method that combined deep-learning convolutional neural network with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensity-projection-based method. The non-contrast region was smoothed and gray level threshold was applied to the contrast and non-contrast regions separately to extract the bladder wall and potential lesions. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify regions of wall thickening candidates. Volume-based features of the wall thickening candidates were analyzed with linear discriminant analysis (LDA) to differentiate bladder wall thickenings from false positives. A data set of 112 patients, 87 with wall thickening and 25 with normal bladders, was collected retrospectively with IRB approval, and split into independent training and test sets. Of the 57 training cases, 44 had bladder wall thickening and 13 were normal. Of the 55 test cases, 43 had wall thickening and 12 were normal. The LDA classifier was trained with the training set and evaluated with the test set. FROC analysis showed that the system achieved sensitivities of 93.2% and 88.4% for the training and test sets, respectively, at 0.5 FPs/case.

  14. Deep learning of contrast-coated serrated polyps for computer-aided detection in CT colonography

    Science.gov (United States)

    Näppi, Janne J.; Pickhardt, Perry; Kim, David H.; Hironaka, Toru; Yoshida, Hiroyuki

    2017-03-01

    Serrated polyps were previously believed to be benign lesions with no cancer potential. However, recent studies have revealed a novel molecular pathway where also serrated polyps can develop into colorectal cancer. CT colonography (CTC) can detect serrated polyps using the radiomic biomarker of contrast coating, but this requires expertise from the reader and current computer-aided detection (CADe) systems have not been designed to detect the contrast coating. The purpose of this study was to develop a novel CADe method that makes use of deep learning to detect serrated polyps based on their contrast-coating biomarker in CTC. In the method, volumetric shape-based features are used to detect polyp sites over soft-tissue and fecal-tagging surfaces of the colon. The detected sites are imaged using multi-angular 2D image patches. A deep convolutional neural network (DCNN) is used to review the image patches for the presence of polyps. The DCNN-based polyp-likelihood estimates are merged into an aggregate likelihood index where highest values indicate the presence of a polyp. For pilot evaluation, the proposed DCNN-CADe method was evaluated with a 10-fold cross-validation scheme using 101 colonoscopy-confirmed cases with 144 biopsy-confirmed serrated polyps from a CTC screening program, where the patients had been prepared for CTC with saline laxative and fecal tagging by barium and iodine-based diatrizoate. The average per-polyp sensitivity for serrated polyps >=6 mm in size was 93+/-7% at 0:8+/-1:8 false positives per patient on average. The detection accuracy was substantially higher that of a conventional CADe system. Our results indicate that serrated polyps can be detected automatically at high accuracy in CTC.

  15. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    International Nuclear Information System (INIS)

    Einarsdóttir, Hildur; Larsen, Rasmus; Ersbøll, Bjarne Kjær; Yaroshenko, Andre; Velroyen, Astrid; Bech, Martin; Pfeiffer, Franz; Hellbach, Katharina; Auweter, Sigrid; Meinel, Felix G; Reiser, Maximilian; Yildirim, Önder; Eickelberg, Oliver

    2015-01-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually annotated to build an experimental dataset. System performance was assessed by: (i) determining the quality of the segmentations; (ii) validating emphysema and fibrosis recognition by a linear support vector machine using leave-one-out cross-validation. In terms of segmentation quality, we obtained an overlap percentage (Ω) 92.63  ±  3.65%, Dice Similarity Coefficient (DSC) 89.74  ±  8.84% and Jaccard Similarity Coefficient 82.39  ±  12.62%. For classification, the accuracy, sensitivity and specificity of diseased lung recognition was 100%. Classification between emphysema and fibrosis resulted in an accuracy of 93%, whilst the sensitivity was 94% and specificity 88%. In addition to the automatic classification of lungs, deviation maps created by the CAD scheme provide a visual aid for medical experts to further assess the severity of pulmonary disease in the lung, and highlights regions affected. (paper)

  16. Identification and red blood cell automated counting from blood smear images using computer-aided system.

    Science.gov (United States)

    Acharya, Vasundhara; Kumar, Preetham

    2018-03-01

    Red blood cell count plays a vital role in identifying the overall health of the patient. Hospitals use the hemocytometer to count the blood cells. Conventional method of placing the smear under microscope and counting the cells manually lead to erroneous results, and medical laboratory technicians are put under stress. A computer-aided system will help to attain precise results in less amount of time. This research work proposes an image-processing technique for counting the number of red blood cells. It aims to examine and process the blood smear image, in order to support the counting of red blood cells and identify the number of normal and abnormal cells in the image automatically. K-medoids algorithm which is robust to external noise is used to extract the WBCs from the image. Granulometric analysis is used to separate the red blood cells from the white blood cells. The red blood cells obtained are counted using the labeling algorithm and circular Hough transform. The radius range for the circle-drawing algorithm is estimated by computing the distance of the pixels from the boundary which automates the entire algorithm. A comparison is done between the counts obtained using the labeling algorithm and circular Hough transform. Results of the work showed that circular Hough transform was more accurate in counting the red blood cells than the labeling algorithm as it was successful in identifying even the overlapping cells. The work also intends to compare the results of cell count done using the proposed methodology and manual approach. The work is designed to address all the drawbacks of the previous research work. The research work can be extended to extract various texture and shape features of abnormal cells identified so that diseases like anemia of inflammation and chronic disease can be detected at the earliest.

  17. Advanced computer-aided design for bone tissue-engineering scaffolds.

    Science.gov (United States)

    Ramin, E; Harris, R A

    2009-04-01

    The design of scaffolds with an intricate and controlled internal structure represents a challenge for tissue engineering. Several scaffold-manufacturing techniques allow the creation of complex architectures but with little or no control over the main features of the channel network such as the size, shape, and interconnectivity of each individual channel, resulting in intricate but random structures. The combined use of computer-aided design (CAD) systems and layer-manufacturing techniques allows a high degree of control over these parameters with few limitations in terms of achievable complexity. However, the design of complex and intricate networks of channels required in CAD is extremely time-consuming since manually modelling hundreds of different geometrical elements, all with different parameters, may require several days to design individual scaffold structures. An automated design methodology is proposed by this research to overcome these limitations. This approach involves the investigation of novel software algorithms, which are able to interact with a conventional CAD program and permit the automated design of several geometrical elements, each with a different size and shape. In this work, the variability of the parameters required to define each geometry has been set as random, but any other distribution could have been adopted. This methodology has been used to design five cubic scaffolds with interconnected pore channels that range from 200 to 800 microm in diameter, each with an increased complexity of the internal geometrical arrangement. A clinical case study, consisting of an integration of one of these geometries with a craniofacial implant, is then presented.

  18. Creation of system of computer-aided design for technological objects

    Science.gov (United States)

    Zubkova, T. M.; Tokareva, M. A.; Sultanov, N. Z.

    2018-05-01

    Due to the competition in the market of process equipment, its production should be flexible, retuning to various product configurations, raw materials and productivity, depending on the current market needs. This process is not possible without CAD (computer-aided design). The formation of CAD begins with planning. Synthesizing, analyzing, evaluating, converting operations, as well as visualization and decision-making operations, can be automated. Based on formal description of the design procedures, the design route in the form of an oriented graph is constructed. The decomposition of the design process, represented by the formalized description of the design procedures, makes it possible to make an informed choice of the CAD component for the solution of the task. The object-oriented approach allows us to consider the CAD as an independent system whose properties are inherited from the components. The first step determines the range of tasks to be performed by the system, and a set of components for their implementation. The second one is the configuration of the selected components. The interaction between the selected components is carried out using the CALS standards. The chosen CAD / CAE-oriented approach allows creating a single model, which is stored in the database of the subject area. Each of the integration stages is implemented as a separate functional block. The transformation of the CAD model into the model of the internal representation is realized by the block of searching for the geometric parameters of the technological machine, in which the XML-model of the construction is obtained on the basis of the feature method from the theory of image recognition. The configuration of integrated components is divided into three consecutive steps: configuring tasks, components, interfaces. The configuration of the components is realized using the theory of "soft computations" using the Mamdani fuzzy inference algorithm.

  19. Studies on computer-aided diagnosis systems for chest radiographs and mammograms (in Japanese)

    International Nuclear Information System (INIS)

    Hara, Takeshi

    2001-01-01

    This thesis describes computer-aided diagnosis (CAD) systems for chest radiographs and mammograms. Preprocessing and imaging processing methods for each CAD system include dynamic range compression and region segmentation technique. A new pattern recognition technique combines genetic algorithms with template matching methods to detect lung nodules. A genetic algorithm was employed to select the optimal shape of simulated nodular shadows to be compared with real lesions on digitized chest images. Detection performance was evaluated using 332 chest radiographs from the database of the Japanese Society of Radiological Technology. Our average true-positive rate was 72.8% with an average of 11 false-positive findings per image. A new detection method using high resolution digital images with 0.05 mm sampling is also proposed for the mammogram CAD system to detect very small microcalcifications. An automated classification method uses feature extraction based on fractal dimension analysis of masses. Using over 200 cases to evaluate the detection of mammographic masses and calcifications, the detection rate of masses and microcalcifications were 87% and 96% with 1.5 and 1.8 false-positive findings, respectively. The classification performance on benign vs malignant lesions, the Az values that were defined by the areas under the ROC curves derived from classification schemes of masses and microcalcifications were 0.84 and 0.89. To demonstrate the practicality of these CAD systems in a computer-network environment, we propose to use the mammogram CAD system via the Internet and WWW. A common gateway interface and server-client approach for the CAD system via the Internet will permit display of the CAD results on ordinary computers

  20. Computer-aided diagnostics of screening mammography using content-based image retrieval

    Science.gov (United States)

    Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo

    2012-03-01

    Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.

  1. Computer aided detection of suspicious regions on digital mammograms : rapid segmentation and feature extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ruggiero, C; Giacomini, M; Sacile, R [DIST - Department of Communication Computer and System Sciences, University of Genova, Via Opera Pia 13, 16145 Genova (Italy); Rosselli Del Turco, M [Centro per lo studio e la prevenzione oncologica, Firenze (Italy)

    1999-12-31

    A method is presented for rapid detection of suspicious regions which consists of two steps. The first step is segmentation based on texture analysis consisting of : histogram equalization, Laws filtering for texture analysis, Gaussian blur and median filtering to enhance differences between tissues in different respects, histogram thresholding to obtain a binary image, logical masking in order to detect regions to be discarded from the analysis, edge detection. This method has been tested on 60 images, obtaining 93% successful detection of suspicious regions. (authors) 4 refs, 9 figs, 1 tabs.

  2. Computer Aided Feature Extraction, Classification and Acceptance Processing of Digital NDE Data

    National Research Council Canada - National Science Library

    Hildreth, Joseph

    1996-01-01

    ... from the inspection of solid rocket motors during fabrication. The computerized system, called the Automated NDE Data Evaluation System or ANDES, was developed under contract to Martin Marietta, now Lockheed Martin...

  3. Computer aided design of piping for a radiochemical plant

    Energy Technology Data Exchange (ETDEWEB)

    Selvaraj, P G; Chandrasekhar, A; Chandrasekar, A V [Reprocessing Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India); Raju, R P; Mahudeeswaran, K V; Kumar, S V [Reprocessing Group, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    In a radiochemical plant such as reprocessing plants, process equipment, storage tanks, liquid transfer systems and the associated pipe lines etc. are housed in series of concrete cells. Availability of limited cell space/volume, provision of various modes of liquid transfers with associated redundancies and instrumentation lines with standby alternatives increase the overall piping density. Designing such high density piping layout without interference is quite complex and needs lot of human efforts. This paper briefly describes development of computer codes for the entire scheme of design, drafting and fabrication of piping for nuclear fuel reprocessing plant. The general organisation of various programs, their functions, the complete sequence of the scheme and the flow of data are presented. High degree of reliability of each routine, considerable error checking facilities, marking legends on the drawings, provision for scaling in drafting and accuracy to the extent of one mm in layout design are some of the important features of this scheme. (author). 1 fig.

  4. Computer-aided process planning in prismatic shape die components based on Standard for the Exchange of Product model data

    Directory of Open Access Journals (Sweden)

    Awais Ahmad Khan

    2015-11-01

    Full Text Available Insufficient technologies made good integration between the die components in design, process planning, and manufacturing impossible in the past few years. Nowadays, the advanced technologies based on Standard for the Exchange of Product model data are making it possible. This article discusses the three main steps for achieving the complete process planning for prismatic parts of the die components. These three steps are data extraction, feature recognition, and process planning. The proposed computer-aided process planning system works as part of an integrated system to cover the process planning of any prismatic part die component. The system is built using Visual Basic with EWDraw system for visualizing the Standard for the Exchange of Product model data file. The system works successfully and can cover any type of sheet metal die components. The case study discussed in this article is taken from a large design of progressive die.

  5. Three-dimensional computer aided design system for plant layout

    International Nuclear Information System (INIS)

    Yoshinaga, Toshiaki; Kiguchi, Takashi; Tokumasu, Shinji; Kumamoto, Kenjiro.

    1986-01-01

    The CAD system for three-dimensional plant layout planning, with which the layout of pipings, cable trays, air conditioning ducts and so on in nuclear power plants can be planned and designed effectively in a short period is reported. This system comprises the automatic routing system by storing the rich experience and know-how of designers in a computer as the knowledge, and deciding the layout automatically following the predetermined sequence by using these, the interactive layout system for reviewing the routing results from higher level and modifying to the optimum layout, the layout evaluation system for synthetically evaluating the layout from the viewpoint of the operability such as checkup and maintenance, and the data base system which enables these effective planning and design. In this report, the total constitution of this system and the technical features and effects of the individual subsystems are outlined. In this CAD system for three-dimensional plant layout planning, knowledge engineering, CAD/CAM, computer graphics and other latest technology were introduced, accordingly by applying this system to plant design, the design can be performed quickly, various case studies can be carried out at planning stage, and systematic and optimum layout planning becomes possible. (Kako, I.)

  6. CADMIO: computer aided design for medical information objects.

    Science.gov (United States)

    Minarelli, D V; Ferri, F; Pisanelli, D M; Ricci, F L; Tittarelli, F

    1995-01-01

    The growth of the computational capability and the tools of graphic software is nowadays available in an integrated manner into the development environments, thus permitting the realization of tool kits capable of handling information that is complex and of different kinds such as the typical medical information. This has given a great impulse to the creation of electronic medical folders joining together with new and stimulating functionality with respect to the usual paper document [1]. In the present work, we propose a tool capable of defining a multimedia electronic medical folder and representing its architecture through a layout that is formed on the basis of the particular data types to be handled. This tool is capable of providing an integrated view of data that, even though they are close in cognitive sense, are often stored and represented apart in the practice. Different approaches to the browsing feature are giving within the system, thus the user can personalize the way of viewing the information stored into the folder or can let the system guide the browsing.

  7. ROCK-CAD - computer aided geological modelling system

    International Nuclear Information System (INIS)

    Saksa, P.

    1995-12-01

    The study discusses surface and solid modelling methods, their use and interfacing with geodata. Application software named ROCK-CAD suitable for geological bedrock modelling has been developed with support from Teollisuuden Voima Oy (TVO). It has been utilized in the Finnish site characterization programme for spent nuclear fuel waste disposal during the 1980s and 1990s. The system is based on the solid modelling technique. It comprises also rich functionality for the particular geological modelling scheme. The ROCK-CAD system provides, among other things, varying graphical vertical and horizontal intersections and perspective illustrations. The specially developed features are the application of the boundary representation modelling method, parametric object generation language and the discipline approach. The ROCK-CAD system has been utilized in modelling spatial distribution of rock types and fracturing structures in TVO's site characterization. The Olkiluoto site at Eurajoki serves as an example case. The study comprises the description of the modelling process, models and illustration examples. The utilization of bedrock models in site characterization, in tentative repository siting as well as in groundwater flow simulation is depicted. The application software has improved the assessment of the sites studied, given a new basis for the documentation of interpretation and modelling work, substituted hand-drawing and enabled digital transfer to numerical analysis. Finally, aspects of presentation graphics in geological modelling are considered. (84 refs., 30 figs., 11 tabs.)

  8. Computer aided detection of clusters of microcalcifications on full field digital mammograms

    International Nuclear Information System (INIS)

    Ge Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, H.-P.; Wei Jun; Helvie, Mark A.; Zhou Chuan

    2006-01-01

    We are developing a computer-aided detection (CAD) system to identify microcalcification clusters (MCCs) automatically on full field digital mammograms (FFDMs). The CAD system includes six stages: preprocessing; image enhancement; segmentation of microcalcification candidates; false positive (FP) reduction for individual microcalcifications; regional clustering; and FP reduction for clustered microcalcifications. At the stage of FP reduction for individual microcalcifications, a truncated sum-of-squares error function was used to improve the efficiency and robustness of the training of an artificial neural network in our CAD system for FFDMs. At the stage of FP reduction for clustered microcalcifications, morphological features and features derived from the artificial neural network outputs were extracted from each cluster. Stepwise linear discriminant analysis (LDA) was used to select the features. An LDA classifier was then used to differentiate clustered microcalcifications from FPs. A data set of 96 cases with 192 images was collected at the University of Michigan. This data set contained 96 MCCs, of which 28 clusters were proven by biopsy to be malignant and 68 were proven to be benign. The data set was separated into two independent data sets for training and testing of the CAD system in a cross-validation scheme. When one data set was used to train and validate the convolution neural network (CNN) in our CAD system, the other data set was used to evaluate the detection performance. With the use of a truncated error metric, the training of CNN could be accelerated and the classification performance was improved. The CNN in combination with an LDA classifier could substantially reduce FPs with a small tradeoff in sensitivity. By using the free-response receiver operating characteristic methodology, it was found that our CAD system can achieve a cluster-based sensitivity of 70, 80, and 90 % at 0.21, 0.61, and 1.49 FPs/image, respectively. For case

  9. Computer aided approach to qualitative and quantitative common cause failure analysis for complex systems

    International Nuclear Information System (INIS)

    Cate, C.L.; Wagner, D.P.; Fussell, J.B.

    1977-01-01

    Common cause failure analysis, also called common mode failure analysis, is an integral part of a complete system reliability analysis. Existing methods of computer aided common cause failure analysis are extended by allowing analysis of the complex systems often encountered in practice. The methods aid in identifying potential common cause failures and also address quantitative common cause failure analysis

  10. A Multidisciplinary Research Team Approach to Computer-Aided Drafting (CAD) System Selection. Final Report.

    Science.gov (United States)

    Franken, Ken; And Others

    A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…

  11. A Computer Aided System for Correlation and Prediction of Phase Equilibrium Data

    DEFF Research Database (Denmark)

    Nielsen, T.L.; Gani, Rafiqul

    2001-01-01

    based on mathematical programming. This paper describes the development of a computer aided system for the systematic derivation of appropriate property models to be used in the service role for a specified problem. As a first step, a library of well-known property models ha's been developed...

  12. An Empathic Avatar in a Computer-Aided Learning Program to Encourage and Persuade Learners

    Science.gov (United States)

    Chen, Gwo-Dong; Lee, Jih-Hsien; Wang, Chin-Yeh; Chao, Po-Yao; Li, Liang-Yi; Lee, Tzung-Yi

    2012-01-01

    Animated pedagogical agents with characteristics such as facial expressions, gestures, and human emotions, under an interactive user interface are attractive to students and have high potential to promote students' learning. This study proposes a convenient method to add an embodied empathic avatar into a computer-aided learning program; learners…

  13. Gathering Empirical Evidence Concerning Links between Computer Aided Design (CAD) and Creativity

    Science.gov (United States)

    Musta'amal, Aede Hatib; Norman, Eddie; Hodgson, Tony

    2009-01-01

    Discussion is often reported concerning potential links between computer-aided designing and creativity, but there is a lack of systematic enquiry to gather empirical evidence concerning such links. This paper reports an indication of findings from other research studies carried out in contexts beyond general education that have sought evidence…

  14. Computer-aided detection in breast MRI : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Dorrius, Monique D.; Jansen-van der Weide, Marijke C.; van Ooijen, Peter M. A.; Pijnappel, Ruud M.; Oudkerk, Matthijs

    To evaluate the additional value of computer-aided detection (CAD) in breast MRI by assessing radiologists' accuracy in discriminating benign from malignant breast lesions. A literature search was performed with inclusion of relevant studies using a commercially available CAD system with automatic

  15. Incorporating Computer-Aided Software in the Undergraduate Chemical Engineering Core Courses

    Science.gov (United States)

    Alnaizy, Raafat; Abdel-Jabbar, Nabil; Ibrahim, Taleb H.; Husseini, Ghaleb A.

    2014-01-01

    Introductions of computer-aided software and simulators are implemented during the sophomore-year of the chemical engineering (ChE) curriculum at the American University of Sharjah (AUS). Our faculty concurs that software integration within the curriculum is beneficial to our students, as evidenced by the positive feedback received from industry…

  16. Computer-Aided Detection of Polyps in CT Colonography Using Logistic Regression

    NARCIS (Netherlands)

    Van Ravesteijn, V.F.; Van Wijk, C.; Vos, F.M.; Truyen, R.; Peters, J.F.; Stoker, J.; Van Vliet, L.J.

    2010-01-01

    We present a computer-aided detection (CAD) system for computed tomography colonography that orders the polyps according to clinical relevance. TheCADsystem consists of two steps: candidate detection and supervised classification. The characteristics of the detection step lead to specific choices

  17. Observer training for computer-aided detection of pulmonary nodules in chest radiography

    NARCIS (Netherlands)

    de Boo, Diederick W.; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J.; Freling, Nicole J.; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M.

    2012-01-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a

  18. Computer-aided Detection of Lung Cancer on Chest Radiographs: Effect on Observer Performance

    NARCIS (Netherlands)

    de Hoop, Bartjan; de Boo, Diederik W.; Gietema, Hester A.; van Hoorn, Frans; Mearadji, Banafsche; Schijf, Laura; van Ginneken, Bram; Prokop, Mathias; Schaefer-Prokop, Cornelia

    2010-01-01

    Purpose: To assess how computer-aided detection (CAD) affects reader performance in detecting early lung cancer on chest radiographs. Materials and Methods: In this ethics committee-approved study, 46 individuals with 49 computed tomographically (CT)-detected and histologically proved lung cancers

  19. Virtual Reality versus Computer-Aided Exposure Treatments for Fear of Flying

    Science.gov (United States)

    Tortella-Feliu, Miquel; Botella, Cristina; Llabres, Jordi; Breton-Lopez, Juana Maria; del Amo, Antonio Riera; Banos, Rosa M.; Gelabert, Joan M.

    2011-01-01

    Evidence is growing that two modalities of computer-based exposure therapies--virtual reality and computer-aided psychotherapy--are effective in treating anxiety disorders, including fear of flying. However, they have not yet been directly compared. The aim of this study was to analyze the efficacy of three computer-based exposure treatments for…

  20. Experiments Using Cell Phones in Physics Classroom Education: The Computer-Aided "g" Determination

    Science.gov (United States)

    Vogt, Patrik; Kuhn, Jochen; Muller, Sebastian

    2011-01-01

    This paper continues the collection of experiments that describe the use of cell phones as experimental tools in physics classroom education. We describe a computer-aided determination of the free-fall acceleration "g" using the acoustical Doppler effect. The Doppler shift is a function of the speed of the source. Since a free-falling objects…

  1. A Computer-Aided Exercise for Checking Novices' Understanding of Market Equilibrium Changes.

    Science.gov (United States)

    Katz, Arnold

    1999-01-01

    Describes a computer-aided supplement to the introductory microeconomics course that enhances students' understanding with simulation-based tools for reviewing what they have learned from lectures and conventional textbooks about comparing market equilibria. Includes a discussion of students' learning progressions and retention after using the…

  2. Effective Computer-Aided Assessment of Mathematics; Principles, Practice and Results

    Science.gov (United States)

    Greenhow, Martin

    2015-01-01

    This article outlines some key issues for writing effective computer-aided assessment (CAA) questions in subjects with substantial mathematical or statistical content, especially the importance of control of random parameters and the encoding of wrong methods of solution (mal-rules) commonly used by students. The pros and cons of using CAA and…

  3. Computer-Aided College Algebra: Learning Components that Students Find Beneficial

    Science.gov (United States)

    Aichele, Douglas B.; Francisco, Cynthia; Utley, Juliana; Wescoatt, Benjamin

    2011-01-01

    A mixed-method study was conducted during the Fall 2008 semester to better understand the experiences of students participating in computer-aided instruction of College Algebra using the software MyMathLab. The learning environment included a computer learning system for the majority of the instruction, a support system via focus groups (weekly…

  4. Possible Computer Vision Systems and Automated or Computer-Aided Edging and Trimming

    Science.gov (United States)

    Philip A. Araman

    1990-01-01

    This paper discusses research which is underway to help our industry reduce costs, increase product volume and value recovery, and market more accurately graded and described products. The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or computer controlled processing. This paper...

  5. CONTRIBUTIONS FOR DEVELOPING OF A COMPUTER AIDED LEARNING ENVIRONMENT OF DESCRIPTIVE GEOMETRY

    Directory of Open Access Journals (Sweden)

    Antonescu Ion

    2009-07-01

    Full Text Available The paper presents the authors’ contributions for developing a computer code for teaching of descriptive geometry using the computer aided learning techniques. The program was implemented using the programming interface and the 3D modeling capabilities of the AutoCAD system.

  6. APPLICATION OF COMPUTER-AIDED TOMOGRAPHY TO VISUALIZE AND QUANTIFY BIOGENIC STRUCTURES IN MARINE SEDIMENTS

    Science.gov (United States)

    We used computer-aided tomography (CT) for 3D visualization and 2D analysis ofmarine sediment cores from 3 stations (at 10, 75 and 118 m depths) with different environmentalimpact. Biogenic structures such as tubes and burrows were quantified and compared among st...

  7. The Power of Computer-aided Tomography to Investigate Marine Benthic Communities

    Science.gov (United States)

    Utilization of Computer-aided-Tomography (CT) technology is a powerful tool to investigate benthic communities in aquatic systems. In this presentation, we will attempt to summarize our 15 years of experience in developing specific CT methods and applications to marine benthic co...

  8. Computer-Aided Detection in Breast Magnetic Resonance Imaging: A Review

    NARCIS (Netherlands)

    Dorrius, M. D.; Van Ooijen, P.M.A.

    2008-01-01

    The aim of this study is to give an overview on the accuracy of the discrimination between benign and malignant breast lesions on MRI with and without the use of a computer-aided detection (CAD) system. One investigator selected relevant articles based on title and abstract. Ten articles were

  9. Diagnosis by computer-aided tomography in patients with carcinomas in the rectum-sigma area

    International Nuclear Information System (INIS)

    Gnann, H.; Huebener, K.H.; Ahlemann, L.M.; Harms, S.

    1984-01-01

    In a retrospective study on the patients at Tuebingen between 1977 and 1980, the diagnostic value of computer-aided tomography was investigated in 232 cases of carcinomas in the rectum-sigma area. 192 examinations were post-operative. Whether computer-aided tomography will catch on as a staging measure in the pre-operative phase must for now remain unanswered until prospective studies on a large number of patients have been carried through. However, it is useful as a decision-taking aid as regards the choice of the operation method and to clarify whether the carcinoma is operable. Far more important in view of the known high rate of recurvency and metastatic spread seems to be the role of computer-aided tomography in the aftercare especially of those patients who had their rectum removed: the diagnosis of the recidivation permits direct therapeutic action (a second operation, radiation therapy) at an early date. The search for clinically not previously known recidivations revealed that computer-aided tomography had in 124 patients with operated rectal carcinoma a high sensitivity of 98 per cent, a specificity of 87 per cent and an accuracy of 91.9 percent. How long after the operation CAT checks should be carried through is quite as uncertain at present as the role of CAT in the staging of those tumors. The authors recommend intervals of 2-3 months within the first two post-operative years. (orig.) [de

  10. New Method and Software for Computer-Aided Flowsheet Design and Analysis

    DEFF Research Database (Denmark)

    K.Tula, Anjan; Gani, Rafiqul; Eden, Mario R.

    2017-01-01

    in the same way as atoms or groups of atoms are synthesized to form molecules in computer aided molecular design (CAMD) techniques. Another important aspect of this method is the integration of economic, sustainability and LCA analyses in the early stages of process synthesis to identify process hotspots...

  11. SMART USE OF COMPUTER-AIDED SPERM ANALYSIS (CASA) TO CHARACTERIZE SPERM MOTION

    Science.gov (United States)

    Computer-aided sperm analysis (CASA) has evolved over the past fifteen years to provide an objective, practical means of measuring and characterizing the velocity and parttern of sperm motion. CASA instruments use video frame-grabber boards to capture multiple images of spermato...

  12. Variation in semen parameters derived from computer-aided semen analysis, within donors and between donors

    NARCIS (Netherlands)

    Wijchman, JG; De Wolf, BTHM; Graaff, R; Arts, EGJM

    2001-01-01

    The development of computer-aided semen analysis (CASA) has made it possible to study sperm motility characteristics objectively and longitudinally. In this 2-year study of 8 sperm donors, we used CASA to measure 7 semen parameters (concentration, percentage of motile spermatozoa, curvilinear

  13. Persons with Alzheimer's Disease Make Phone Calls Independently Using a Computer-Aided Telephone System

    Science.gov (United States)

    Perilli, Viviana; Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Cassano, Germana; Cordiano, Noemi; Pinto, Katia; Minervini, Mauro G.; Oliva, Doretta

    2012-01-01

    This study assessed whether four patients with a diagnosis of Alzheimer's disease could make independent phone calls via a computer-aided telephone system. The study was carried out according to a non-concurrent multiple baseline design across participants. All participants started with baseline during which the telephone system was not available,…

  14. A computer-aided framework for development, identification andmanagement of physiologically-based pharmacokinetic models

    DEFF Research Database (Denmark)

    Heitzig, Martina; Linninger, Andreas; Sin, Gürkan

    2014-01-01

    The objective of this work is the development of a generic computer-aided modelling framework to support the development of physiologically-based pharmacokinetic models thereby increasing the efficiency and quality of the modelling process. In particular, the framework systematizes the modelling...

  15. SOFTWARE FOR COMPUTER-AIDED DESIGN OF CROSS-WEDGE ROLLING

    OpenAIRE

    A. A. Abramov; S. V. Medvedev

    2013-01-01

    The issues of computer technology creation of 3D-design and engineering analysis of metal forming processes using cross wedge rolling methods (CWR) are considered. The developed software for computer-aided design and simulation of cross-wedge rolling is described.

  16. DEVELOPMENT AND USE OF COMPUTER-AIDED PROCESS ENGINEERING TOOLS FOR POLLUTION PREVENTION

    Science.gov (United States)

    The use of Computer-Aided Process Engineering (CAPE) and process simulation tools has become established industry practice to predict simulation software, new opportunities are available for the creation of a wide range of ancillary tools that can be used from within multiple sim...

  17. Framework for Computer-Aided Evolution of Object-Oriented Designs

    NARCIS (Netherlands)

    Ciraci, S.; van den Broek, P.M.; Aksit, Mehmet

    2008-01-01

    In this paper, we describe a framework for the computer aided evolution of the designs of object-oriented software systems. Evolution mechanisms are software structures that prepare software for certain type of evolutions. The framework uses a database which holds the evolution mechanisms, modeled

  18. The computer-aided design of a servo system as a multiple-criteria decision problem

    NARCIS (Netherlands)

    Udink ten Cate, A.J.

    1986-01-01

    This paper treats the selection of controller gains of a servo system as a multiple-criteria decision problem. In contrast to the usual optimization-based approaches to computer-aided design, inequality constraints are included in the problem as unconstrained objectives. This considerably simplifies

  19. USE OF COMPUTER-AIDED PROCESS ENGINEERING TOOL IN POLLUTION PREVENTION

    Science.gov (United States)

    Computer-Aided Process Engineering has become established in industry as a design tool. With the establishment of the CAPE-OPEN software specifications for process simulation environments. CAPE-OPEN provides a set of "middleware" standards that enable software developers to acces...

  20. Data Management Standards in Computer-aided Acquisition and Logistic Support (CALS)

    Science.gov (United States)

    Jefferson, David K.

    1990-01-01

    Viewgraphs and discussion on data management standards in computer-aided acquisition and logistic support (CALS) are presented. CALS is intended to reduce cost, increase quality, and improve timeliness of weapon system acquisition and support by greatly improving the flow of technical information. The phase 2 standards, industrial environment, are discussed. The information resource dictionary system (IRDS) is described.

  1. Teaching Neuroanatomy Using Computer-Aided Learning: What Makes for Successful Outcomes?

    Science.gov (United States)

    Svirko, Elena; Mellanby, Jane

    2017-01-01

    Computer-aided learning (CAL) is an integral part of many medical courses. The neuroscience course at Oxford University for medical students includes CAL course of neuroanatomy. CAL is particularly suited to this since neuroanatomy requires much detailed three-dimensional visualization, which can be presented on screen. The CAL course was…

  2. Technology and Jobs: Computer-Aided Design. Numerical-Control Machine-Tool Operators. Office Automation.

    Science.gov (United States)

    Stanton, Michael; And Others

    1985-01-01

    Three reports on the effects of high technology on the nature of work include (1) Stanton on applications and implications of computer-aided design for engineers, drafters, and architects; (2) Nardone on the outlook and training of numerical-control machine tool operators; and (3) Austin and Drake on the future of clerical occupations in automated…

  3. Impact of Computer-Aided Warfarin Dosing in a Saudi Arabian ...

    African Journals Online (AJOL)

    Purpose: To compare the efficacy of computer-aided dosing using Coagclinic (a web-based software) with physician dosing in patients receiving warfarin for various cardiac indications. Methods: In order to calculate the effectiveness of physician managed anticoagulation dosing, we calculated the “percentage of time ...

  4. Computer aided cooling curve analysis for Al-5Si and Al-11Si alloys ...

    African Journals Online (AJOL)

    The effect of grain refiner, modifier, and combination of grain refiner cum modifier was studied on Al-5Si and Al-11Si alloys using computer aided cooling curve analysis. For combined grain refinement and modification effect, Al-Ti-B-Sr single master alloy was developed that acted as both grain refiner and modifier.

  5. The Effects of Computer-Aided Concept Cartoons and Outdoor Science Activities on Light Pollution

    Science.gov (United States)

    Aydin, Güliz

    2015-01-01

    The purpose of this study is to create an awareness of light pollution on seventh grade students via computer aided concept cartoon applications and outdoor science activities and to help them develop solutions; and to determine student opinions on the practices carried out. The study was carried out at a middle school in Mugla province of Aegean…

  6. On Combining Multiple-Instance Learning and Active Learning for Computer-Aided Detection of Tuberculosis

    NARCIS (Netherlands)

    Melendez Rodriguez, J.C.; Ginneken, B. van; Maduskar, P.; Philipsen, R.H.H.M.; Ayles, H.; Sanchez, C.I.

    2016-01-01

    The major advantage of multiple-instance learning (MIL) applied to a computer-aided detection (CAD) system is that it allows optimizing the latter with case-level labels instead of accurate lesion outlines as traditionally required for a supervised approach. As shown in previous work, a MIL-based

  7. Tolerance to missing data using a likelihood ratio based classifier for computer-aided classification of breast cancer

    International Nuclear Information System (INIS)

    Bilska-Wolak, Anna O; Floyd, Carey E Jr

    2004-01-01

    While mammography is a highly sensitive method for detecting breast tumours, its ability to differentiate between malignant and benign lesions is low, which may result in as many as 70% of unnecessary biopsies. The purpose of this study was to develop a highly specific computer-aided diagnosis algorithm to improve classification of mammographic masses. A classifier based on the likelihood ratio was developed to accommodate cases with missing data. Data for development included 671 biopsy cases (245 malignant), with biopsy-proved outcome. Sixteen features based on the BI-RADS TM lexicon and patient history had been recorded for the cases, with 1.3 ± 1.1 missing feature values per case. Classifier evaluation methods included receiver operating characteristic and leave-one-out bootstrap sampling. The classifier achieved 32% specificity at 100% sensitivity on the 671 cases with 16 features that had missing values. Utilizing just the seven features present for all cases resulted in decreased performance at 100% sensitivity with average 19% specificity. No cases and no feature data were omitted during classifier development, showing that it is more beneficial to utilize cases with missing values than to discard incomplete cases that cannot be handled by many algorithms. Classification of mammographic masses was commendable at high sensitivity levels, indicating that benign cases could be potentially spared from biopsy

  8. A method of computer aided design with self-generative models in NX Siemens environment

    Science.gov (United States)

    Grabowik, C.; Kalinowski, K.; Kempa, W.; Paprocka, I.

    2015-11-01

    Currently in CAD/CAE/CAM systems it is possible to create 3D design virtual models which are able to capture certain amount of knowledge. These models are especially useful in an automation of routine design tasks. These models are known as self-generative or auto generative and they can behave in an intelligent way. The main difference between the auto generative and fully parametric models consists in the auto generative models ability to self-organizing. In this case design model self-organizing means that aside from the possibility of making of automatic changes of model quantitative features these models possess knowledge how these changes should be made. Moreover they are able to change quality features according to specific knowledge. In spite of undoubted good points of self-generative models they are not so often used in design constructional process which is mainly caused by usually great complexity of these models. This complexity makes the process of self-generative time and labour consuming. It also needs a quite great investment outlays. The creation process of self-generative model consists of the three stages it is knowledge and information acquisition, model type selection and model implementation. In this paper methods of the computer aided design with self-generative models in NX Siemens CAD/CAE/CAM software are presented. There are the five methods of self-generative models preparation in NX with: parametric relations model, part families, GRIP language application, knowledge fusion and OPEN API mechanism. In the paper examples of each type of the self-generative model are presented. These methods make the constructional design process much faster. It is suggested to prepare this kind of self-generative models when there is a need of design variants creation. The conducted research on assessing the usefulness of elaborated models showed that they are highly recommended in case of routine tasks automation. But it is still difficult to distinguish

  9. New layer-based imaging and rapid prototyping techniques for computer-aided design and manufacture of custom dental restoration.

    Science.gov (United States)

    Lee, M-Y; Chang, C-C; Ku, Y C

    2008-01-01

    Fixed dental restoration by conventional methods greatly relies on the skill and experience of the dental technician. The quality and accuracy of the final product depends mostly on the technician's subjective judgment. In addition, the traditional manual operation involves many complex procedures, and is a time-consuming and labour-intensive job. Most importantly, no quantitative design and manufacturing information is preserved for future retrieval. In this paper, a new device for scanning the dental profile and reconstructing 3D digital information of a dental model based on a layer-based imaging technique, called abrasive computer tomography (ACT) was designed in-house and proposed for the design of custom dental restoration. The fixed partial dental restoration was then produced by rapid prototyping (RP) and computer numerical control (CNC) machining methods based on the ACT scanned digital information. A force feedback sculptor (FreeForm system, Sensible Technologies, Inc., Cambridge MA, USA), which comprises 3D Touch technology, was applied to modify the morphology and design of the fixed dental restoration. In addition, a comparison of conventional manual operation and digital manufacture using both RP and CNC machining technologies for fixed dental restoration production is presented. Finally, a digital custom fixed restoration manufacturing protocol integrating proposed layer-based dental profile scanning, computer-aided design, 3D force feedback feature modification and advanced fixed restoration manufacturing techniques is illustrated. The proposed method provides solid evidence that computer-aided design and manufacturing technologies may become a new avenue for custom-made fixed restoration design, analysis, and production in the 21st century.

  10. Common features of electrochemical kinetics of the lithium electrode in different electrolyte systems

    International Nuclear Information System (INIS)

    Churikov, A.V.; L'vov, A.L.; Gamayunova, I.M.; Shirokov, A.V.

    1999-01-01

    Electrochemical behaviour of Li-electrode in LiAlCl 4 solutions in thienyl chloride and LiBF 4 solutions in γ-butyrolactone is studied as well as Li-electrode with Li 2 CO 3 protected film in LiClO 4 solution in mixed solvent (propylene carbonate and dimethoxyethane). Common regularities of Li-electrode electrochemical kinetic are discussed. Methods of electrode impedance spectroscopy and pulse voltametry are used for investigations

  11. Thermoluminescence kinetic features of Lithium Iodide (LiI) single crystal grown by vertical Bridgman technique

    Science.gov (United States)

    Daniel, D. Joseph; Kim, H. J.; Kim, Sunghwan; Khan, Sajid

    2017-08-01

    Single crystal of pure Lithium Iodide (LiI) has been grown from melt by using the vertical Bridgman technique. Thermoluminescence (TL) Measurements were carried out at 1 K/s following X-ray irradiation. The TL glow curve consists of a dominant peak at (peak-maximum Tm) 393 K and one low temperature peak of weaker intensity at 343 K. The order of kinetics (b), activation energy (E), and the frequency factor (S) for a prominent TL glow peak observed around 393 K for LiI crystals are reported for the first time. The peak shape analysis of the glow peak indicates the kinetics to be of the first order. The value of E is calculated using various standard methods such as initial rise (IR), whole glow peak (WGP), peak shape (PS), computerized glow curve deconvolution (CGCD) and Variable Heating rate (VHR) methods. An average value of 1.06 eV is obtained in this case. In order to validate the obtained parameters, numerically integrated TL glow curve has been generated using experimentally determined kinetic parameters. The effective atomic number (Zeff) for this material was determined and found to be 52. X-ray induced emission spectra of pure LiI single crystal are studied at room temperature and it is found that the sample exhibit sharp emission at 457 nm and broad emission at 650 nm.

  12. Computer-aided design and computer-aided modeling (CAD/CAM) generated surgical splints, cutting guides and custom-made implants: Which indications in orthognathic surgery?

    Science.gov (United States)

    Scolozzi, P

    2015-12-01

    The purpose of the present report was to describe our indications, results and complications of computer-aided design and computer-aided modeling CAD/CAM surgical splints, cutting guides and custom-made implants in orthognathic surgery. We analyzed the clinical and radiological data of ten consecutive patients with dentofacial deformities treated using a CAD/CAM technique. Four patients had surgical splints and cutting guides for correction of maxillomandibular asymmetries, three had surgical cutting guides and customized internal distractors for correction of severe maxillary deficiencies and three had custom-made implants for additional chin contouring and/or mandibular defects following bimaxillary osteotomies and sliding genioplasty. We recorded age, gender, dentofacial deformity, surgical procedure and intra- and postoperative complications. All of the patients had stable cosmetic results with a high rate of patient satisfaction at the 1-year follow-up examination. No intra- and/or postoperative complications were encountered during any of the different steps of the procedure. This study demonstrated that the application of CAD/CAM patient-specific surgical splints, cutting guides and custom-made implants in orthognathic surgery allows for a successful outcome in the ten patients presented in this series. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Custom-Made Computer-Aided-Design/Computer-Aided-Manufacturing Biphasic Calcium-Phosphate Scaffold for Augmentation of an Atrophic Mandibular Anterior Ridge

    Directory of Open Access Journals (Sweden)

    Francesco Guido Mangano

    2015-01-01

    Full Text Available This report documents the clinical, radiographic, and histologic outcome of a custom-made computer-aided-design/computer-aided-manufactured (CAD/CAM scaffold used for the alveolar ridge augmentation of a severely atrophic anterior mandible. Computed tomographic (CT images of an atrophic anterior mandible were acquired and modified into a 3-dimensional (3D reconstruction model; this was transferred to a CAD program, where a custom-made scaffold was designed. CAM software generated a set of tool-paths for the manufacture of the scaffold on a computer-numerical-control milling machine into the exact shape of the 3D design. A custom-made scaffold was milled from a synthetic micromacroporous biphasic calcium phosphate (BCP block. The scaffold closely matched the shape of the defect: this helped to reduce the time for the surgery and contributed to good healing. One year later, newly formed and well-integrated bone was clinically available, and two implants (AnyRidge, MegaGen, Gyeongbuk, South Korea were placed. The histologic samples retrieved from the implant sites revealed compact mature bone undergoing remodelling, marrow spaces, and newly formed trabecular bone surrounded by residual BCP particles. This study demonstrates that custom-made scaffolds can be fabricated by combining CT scans and CAD/CAM techniques. Further studies on a larger sample of patients are needed to confirm these results.

  14. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing.

    Science.gov (United States)

    Gunsoy, S; Ulusoy, M

    2016-01-01

    The purpose of this study was to evaluate the internal and marginal fit of chrome cobalt (Co-Cr) crowns were fabricated with laser sintering, computer-aided design (CAD) and computer-aided manufacturing, and conventional methods. Polyamide master and working models were designed and fabricated. The models were initially designed with a software application for three-dimensional (3D) CAD (Maya, Autodesk Inc.). All models were fabricated models were produced by a 3D printer (EOSINT P380 SLS, EOS). 128 1-unit Co-Cr fixed dental prostheses were fabricated with four different techniques: Conventional lost wax method, milled wax with lost-wax method (MWLW), direct laser metal sintering (DLMS), and milled Co-Cr (MCo-Cr). The cement film thickness of the marginal and internal gaps was measured by an observer using a stereomicroscope after taking digital photos in ×24. Best fit rates according to mean and standard deviations of all measurements was in DLMS both in premolar (65.84) and molar (58.38) models in μm. A significant difference was found DLMS and the rest of fabrication techniques (P 0.05). DMLS was best fitting fabrication techniques for single crown based on the results.The best fit was found in marginal; the larger gap was found in occlusal.All groups were within the clinically acceptable misfit range.

  15. Ideal observer estimation and generalized ROC analysis for computer-aided diagnosis

    International Nuclear Information System (INIS)

    Edwards, Darrin C.

    2004-01-01

    The research presented in this dissertation represents an innovative application of computer-aided diagnosis and signal detection theory to the specific task of early detection of breast cancer in the context of screening mammography. A number of automated schemes have been developed in our laboratory to detect masses and clustered microcalcifications in digitized mammograms, on the one hand, and to classify known lesions as malignant or benign, on the other. The development of fully automated classification schemes is difficult, because the output of a detection scheme will contain false-positive detections in addition to detected malignant and benign lesions, resulting in a three-class classification task. Researchers have so far been unable to extend successful tools for analyzing two-class classification tasks, such as receiver operating characteristic (ROC) analysis, to three-class classification tasks. The goals of our research were to use Bayesian artificial neural networks to estimate ideal observer decision variables to both detect and classify clustered microcalcifications and mass lesions in mammograms, and to derive substantial theoretical results indicating potential avenues of approach toward the three-class classification task. Specifically, we have shown that an ideal observer in an N-class classification task achieves an optimal ROC hypersurface, just as the two-class ideal observer achieves an optimal ROC curve; and that an obvious generalization of a well-known two-class performance metric, the area under the ROC curve, is not useful as a performance metric in classification tasks with more than two classes. This work is significant for three reasons. First, it involves the explicit estimation of feature-based (as opposed to image-based) ideal observer decision variables in the tasks of detecting and classifying mammographic lesions. Second, it directly addresses the three-class classification task of distinguishing malignant lesions, benign

  16. Specific features of kinetics of He3-He4 solid solution transformations at superlow temperatures

    International Nuclear Information System (INIS)

    Mikheev, V.A.; Majdanov, V.A.; Mikhin, N.P.

    1986-01-01

    The NMR data on the phase transition kinetics of 3 He- 4 He solid solutions at T=100 mK are considered. Studied are solid helium samples of a molecular volume of 20.55 cm 2 /mol with a 3 He content of 0.54 %. An unusually long phase transition time is found which is dependent on the prehistory of sample. The spin diffusion of 3 He in the transformated solution concentrated phase is found to be of a quasi-one-dimensional nature with the diffusion coefficient value typical of liquid

  17. Kinetics features changes before and after intra-articular hyaluronic acid injections in patients with knee osteoarthritis.

    Science.gov (United States)

    Tang, Alice Chu-Wen; Tang, Simon Fuk-Tan; Hong, Wei-Hsien; Chen, Hsieh-Ching

    2015-02-01

    To examine the kinetic features in patients with knee osteoarthritis (OA) after intra-articular hyaluronic acid (IAHA) injections in different time periods. A single group repeated measures study. Gait laboratory in a tertiary hospital. Twenty-five subjects with bilateral symptomatic knee OA and 15 healthy control subjects. Gait analyses were performed in both control and OA groups before (baseline), and after the completion of IAHA injections (1 week, 3 months, and 6 months). Knee pain and functional indices were assessed using a visual analogue scale (VAS) and the Lequesne function Index (LI). Joint kinetic changes were analyzed in the frontal and sagittal planes with 6-camera motion analysis system and two AMTI force plates. VAS and LI scores were both improved in OA group after IAHA injections (pinjections (pinjections can provide significant pain relief and improvement in activity of daily living function for patients with knee OA. However, the reduction in pain and the increase in knee adduction moment may last up to 6 months. This may cause excessive loading on the knee joints, which may further accelerate the rate of knee degeneration. As a result, longer study time is needed to determine whether the observed kinetic findings in this study are associated with detrimental outcomes on the knee joints. © 2015 Elsevier B.V. All rights reserved.

  18. Research on computer aided testing of pilot response to critical in-flight events

    Science.gov (United States)

    Giffin, W. C.; Rockwell, T. H.; Smith, P. J.

    1984-01-01

    Experiments on pilot decision making are described. The development of models of pilot decision making in critical in flight events (CIFE) are emphasized. The following tests are reported on the development of: (1) a frame system representation describing how pilots use their knowledge in a fault diagnosis task; (2) assessment of script norms, distance measures, and Markov models developed from computer aided testing (CAT) data; and (3) performance ranking of subject data. It is demonstrated that interactive computer aided testing either by touch CRT's or personal computers is a useful research and training device for measuring pilot information management in diagnosing system failures in simulated flight situations. Performance is dictated by knowledge of aircraft sybsystems, initial pilot structuring of the failure symptoms and efficient testing of plausible causal hypotheses.

  19. On the convergence of nanotechnology and Big Data analysis for computer-aided diagnosis.

    Science.gov (United States)

    Rodrigues, Jose F; Paulovich, Fernando V; de Oliveira, Maria Cf; de Oliveira, Osvaldo N

    2016-04-01

    An overview is provided of the challenges involved in building computer-aided diagnosis systems capable of precise medical diagnostics based on integration and interpretation of data from different sources and formats. The availability of massive amounts of data and computational methods associated with the Big Data paradigm has brought hope that such systems may soon be available in routine clinical practices, which is not the case today. We focus on visual and machine learning analysis of medical data acquired with varied nanotech-based techniques and on methods for Big Data infrastructure. Because diagnosis is essentially a classification task, we address the machine learning techniques with supervised and unsupervised classification, making a critical assessment of the progress already made in the medical field and the prospects for the near future. We also advocate that successful computer-aided diagnosis requires a merge of methods and concepts from nanotechnology and Big Data analysis.

  20. Freedom and necessity in computer aided composition: A thinking framework and its application

    Science.gov (United States)

    Kretz, Johannes

    This paper presents some of the author's experiences with computer aided composition (CAC): the modeling of physical movements is used to obtain plausible musical gestures in interaction with constraint programming (rule based expert systems) in order to achieve precisely structured, consistent musical material with strong inner logic and syntax in pitch material. The "Constraints Engine" by Michael Laurson implemented in OpenMusic (IRCAM) or PWGL (Sibelius Academy) can be used to set up an interactive framework for composition, which offers a balance of freedom (allowing chance operations and arbitrary decisions of the composer) and necessity (through strict rules as well as through criteria for optimization). Computer Aided Composition is moving far beyond being "algorithmic" or "mechanical". This paper proposes an approach based on evolutionary epistemology (by the Austrian biologist and philosopher Rupert Riedl). The aim is a holistic synthesis of artistic freedom and coherent structures similar to the grown order of nature.

  1. Computer-Aided Model Based Analysis for Design and Operation of a Copolymerization Process

    DEFF Research Database (Denmark)

    Lopez-Arenas, Maria Teresa; Sales-Cruz, Alfonso Mauricio; Gani, Rafiqul

    2006-01-01

    . This will allow analysis of the process behaviour, contribute to a better understanding of the polymerization process, help to avoid unsafe conditions of operation, and to develop operational and optimizing control strategies. In this work, through a computer-aided modeling system ICAS-MoT, two first......The advances in computer science and computational algorithms for process modelling, process simulation, numerical methods and design/synthesis algorithms, makes it advantageous and helpful to employ computer-aided modelling systems and tools for integrated process analysis. This is illustrated......-principles models have been investigated with respect to design and operational issues for solution copolymerization reactors in general, and for the methyl methacrylate/vinyl acetate system in particular. The Model 1 is taken from literature and is commonly used for low conversion region, while the Model 2 has...

  2. Chapter 6 – Computer-Aided Molecular Design and Property Prediction

    DEFF Research Database (Denmark)

    Gani, Rafiqul; Zhang, L.; Kalakul, Sawitree

    2017-01-01

    for the initial stages of the design/development process. Therefore, computer-aided molecular design and property prediction techniques are two topics that play important roles in chemical product design, analysis, and application. In this chapter, an overview of the concepts, methods, and tools related......Today's society needs many chemical-based products for its survival, nutrition, health, transportation, agriculture, and the functioning of processes. Chemical-based products have to be designed/developed in order to meet these needs, while at the same time, they must be innovative and sustainable...... to these two topics are given. In addition, a generic computer-aided framework for the design of molecules, mixtures, and blends is presented. The application of the framework is highlighted for molecular products through two case studies involving the design of refrigerants and surfactants....

  3. A Computer-Aided FPS-Oriented Approach for Construction Briefing

    Institute of Scientific and Technical Information of China (English)

    Xiaochun Luo; Qiping Shen

    2008-01-01

    Function performance specification (FPS) is one of the value management (VM) techniques de- veloped for the explicit statement of optimum product definition. This technique is widely used in software engineering and manufacturing industry, and proved to be successful to perform product defining tasks. This paper describes an FPS-odented approach for construction briefing, which is critical to the successful deliv- ery of construction projects. Three techniques, i.e., function analysis system technique, shared space, and computer-aided toolkit, are incorporated into the proposed approach. A computer-aided toolkit is developed to facilitate the implementation of FPS in the briefing processes. This approach can facilitate systematic, ef- ficient identification, clarification, and representation of client requirements in trail running. The limitations of the approach and future research work are also discussed at the end of the paper.

  4. Tailor-made Design of Chemical Blends using Decomposition-based Computer-aided Approach

    DEFF Research Database (Denmark)

    Yunus, Nor Alafiza; Manan, Zainuddin Abd.; Gernaey, Krist

    (properties). In this way, first the systematic computer-aided technique establishes the search space, and then narrows it down in subsequent steps until a small number of feasible and promising candidates remain and then experimental work may be conducted to verify if any or all the candidates satisfy......Computer aided technique is an efficient approach to solve chemical product design problems such as design of blended liquid products (chemical blending). In chemical blending, one tries to find the best candidate, which satisfies the product targets defined in terms of desired product attributes...... is decomposed into two stages. The first stage investigates the mixture stability where all unstable mixtures are eliminated and the stable blend candidates are retained for further testing. In the second stage, the blend candidates have to satisfy a set of target properties that are ranked according...

  5. A computer-aided molecular design framework for crystallization solvent design

    DEFF Research Database (Denmark)

    Karunanithi, Arunprakash T.; Achenie, Luke E.K.; Gani, Rafiqul

    2006-01-01

    One of the key decisions in designing solution crystallization processes is the selection of solvents. In this paper, we present a computer-aided molecular design (CAMD) framework for the design and selection of solvents and/or anti-solvents for solution crystallization. The CAMD problem is formu......One of the key decisions in designing solution crystallization processes is the selection of solvents. In this paper, we present a computer-aided molecular design (CAMD) framework for the design and selection of solvents and/or anti-solvents for solution crystallization. The CAMD problem...... solvent molecules. Solvent design and selection for two types of solution crystallization processes namely cooling crystallization and drowning out crystallization are presented. In the first case study, the design of single compound solvent for crystallization of ibuprofen, which is an important...

  6. Computer Aided Measurement Laser (CAML): technique to quantify post-mastectomy lymphoedema

    International Nuclear Information System (INIS)

    Trombetta, Chiara; Abundo, Paolo; Felici, Antonella; Ljoka, Concetta; Foti, Calogero; Cori, Sandro Di; Rosato, Nicola

    2012-01-01

    Lymphoedema can be a side effect of cancer treatment. Eventhough several methods for assessing lymphoedema are used in clinical practice, an objective quantification of lymphoedema has been problematic. The aim of the study was to determine the objectivity, reliability and repeatability of the computer aided measurement laser (CAML) technique. CAML technique is based on computer aided design (CAD) methods and requires an infrared laser scanner. Measurements are scanned and the information describing size and shape of the limb allows to design the model by using the CAD software. The objectivity and repeatability was established in the beginning using a phantom. Consequently a group of subjects presenting post-breast cancer lymphoedema was evaluated using as a control the contralateral limb. Results confirmed that in clinical settings CAML technique is easy to perform, rapid and provides meaningful data for assessing lymphoedema. Future research will include a comparison of upper limb CAML technique between healthy subjects and patients with known lymphoedema.

  7. Computer-Aided Design Method of Warp-Knitted Jacquard Spacer Fabrics

    Directory of Open Access Journals (Sweden)

    Li Xinxin

    2016-06-01

    Full Text Available Based on a further study on knitting and jacquard principles, this paper presents a mathematical design model to make computer-aided design of warp-knitted jacquard spacer fabrics more efficient. The mathematical model with matrix method employs three essential elements of chain notation, threading and Jacquard designing. With this model, the processing to design warp-knitted jacquard spacer fabrics with CAD software is also introduced. In this study, the sports shoes which have separated functional areas according to the feet structure and characteristics of movement are analysed. The results show the different patterns on Jacquard spacer fabrics that are seamlessly stitched with jacquard technics. The computer-aided design method of warp-knitted jacquard spacer fabrics is efficient and simple.

  8. Computer-aided Nonlinear Control System Design Using Describing Function Models

    CERN Document Server

    Nassirharand, Amir

    2012-01-01

    A systematic computer-aided approach provides a versatile setting for the control engineer to overcome the complications of controller design for highly nonlinear systems. Computer-aided Nonlinear Control System Design provides such an approach based on the use of describing functions. The text deals with a large class of nonlinear systems without restrictions on the system order, the number of inputs and/or outputs or the number, type or arrangement of nonlinear terms. The strongly software-oriented methods detailed facilitate fulfillment of tight performance requirements and help the designer to think in purely nonlinear terms, avoiding the expedient of linearization which can impose substantial and unrealistic model limitations and drive up the cost of the final product. Design procedures are presented in a step-by-step algorithmic format each step being a functional unit with outputs that drive the other steps. This procedure may be easily implemented on a digital computer with example problems from mecha...

  9. Analysis of three-phase power-supply systems using computer-aided design programs

    International Nuclear Information System (INIS)

    Oberst, E.F.

    1977-01-01

    A major concern of every designer of large, three-phase power-supply systems is the protection of system components from overvoltage transients. At present, three computer-aided circuit design programs are available in the Magnetic Fusion Energy (MFE) National Computer Center that can be used to analyze three-phase power systems: MINI SCEPTRE, SPICE I, and SPICE II. These programs have been used at Lawrence Livermore Laboratory (LLL) to analyze the operation of a 200-kV dc, 20-A acceleration power supply for the High Voltage Test Stand. Various overvoltage conditions are simulated and the effectiveness of system protective devices is observed. The simulated overvoltage conditions include such things as circuit breaker openings, pulsed loading, and commutation voltage surges in the rectifiers. These examples are used to illustrate the use of the computer-aided, circuit-design programs discussed in this paper

  10. Computer Aided Design and Analysis of Separation Processes with Electrolyte Systems

    DEFF Research Database (Denmark)

    A methodology for computer aided design and analysis of separation processes involving electrolyte systems is presented. The methodology consists of three main parts. The thermodynamic part "creates" the problem specific property model package, which is a collection of pure component and mixture...... property models. The design and analysis part generates process (flowsheet) alternatives, evaluates/analyses feasibility of separation and provides a visual operation path for the desired separation. The simulation part consists of a simulation/calculation engine that allows the screening and validation...... of process alternatives. For the simulation part, a general multi-purpose, multi-phase separation model has been developed and integrated to an existing computer aided system. Application of the design and analysis methodology is highlighted through two illustrative case studies....

  11. Computer Aided Design and Analysis of Separation Processes with Electrolyte Systems

    DEFF Research Database (Denmark)

    Takano, Kiyoteru; Gani, Rafiqul; Kolar, P.

    2000-01-01

    A methodology for computer aided design and analysis of separation processes involving electrolyte systems is presented. The methodology consists of three main parts. The thermodynamic part 'creates' the problem specific property model package, which is a collection of pure component and mixture...... property models. The design and analysis part generates process (flowsheet) alternatives, evaluates/analyses feasibility of separation and provides a visual operation path for the desired separation. The simulation part consists of a simulation/calculation engine that allows the screening and validation...... of process alternatives. For the simulation part, a general multi-purpose, multi-phase separation model has been developed and integrated to an existing computer aided system. Application of the design and analysis methodology is highlighted through two illustrative case studies, (C) 2000 Elsevier Science...

  12. Computer-aided diagnosis and volumetry of pulmonary nodules: current concepts and future perspectives

    International Nuclear Information System (INIS)

    Marten, K.; Rummeny, E.J.; Engelke, C.

    2005-01-01

    For computer-aided detection (CAD) and volumetry of small pulmonary nodules, a number of algorithms have been developed for multislice CT data sets in recent years, with the goal of improving the diagnostic work-up and the follow-up of findings. Recent data show that the detection of small lesions may improve with CAD, suggesting that especially experienced readers may benefit from using CAD systems. This has lead to the recommendation of CAD as a replacement of the second reader in clinical practice. Furthermore, computer-aided volumetry of pulmonary nodules allows a precise determination of nodular growth rates as a prerequisite for a better classification of nodules as benign or malignant. In this article, we review recent developments of CAD and volumetry tools for pulmonary nodules, and address open questions regarding the use of these software tools in clinical routine. (orig.)

  13. [Research and application of computer-aided technology in restoration of maxillary defect].

    Science.gov (United States)

    Cheng, Xiaosheng; Liao, Wenhe; Hu, Qingang; Wang, Qian; Dai, Ning

    2008-08-01

    This paper presents a new method of designing restoration model of maxillectomy defect through Computer aided technology. Firstly, 3D maxillectomy triangle mesh model is constructed from Helical CT data. Secondly, the triangle mesh model is transformed into initial computer-aided design (CAD) model of maxillectomy through reverse engineering software. Thirdly, the 3D virtual restoration model of maxillary defect is obtained after designing and adjusting the initial CAD model through CAD software according to the patient's practical condition. Therefore, the 3D virtual restoration can be fitted very well with the broken part of maxilla. The exported design data can be manufactured using rapid prototyping technology and foundry technology. Finally, the result proved that this method is effective and feasible.

  14. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams

    Science.gov (United States)

    Bennamoun, Mohammed

    2014-01-01

    In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses. PMID:24817888

  15. Computer-aided modeling for efficient and innovative product-process engineering

    DEFF Research Database (Denmark)

    Heitzig, Martina

    Model-based computer aided product-process engineering has attained increased importance in a number of industries, including pharmaceuticals, petrochemicals, fine chemicals, polymers, biotechnology, food, energy and water. This trend is set to continue due to the substantial benefits computer...... in chemical and biochemical engineering have been solved to illustrate the application of the generic modelling methodology, the computeraided modelling framework and the developed software tool.......-aided methods provide. The key prerequisite of computer-aided productprocess engineering is however the availability of models of different types, forms and application modes. The development of the models required for the systems under investigation tends to be a challenging, time-consuming and therefore cost...

  16. Study on computer-aided simulation procedure for multicomponent separating cascade

    International Nuclear Information System (INIS)

    Kinoshita, Masahiro

    1982-11-01

    The present report reviews the author's study on the computer-aided simulation procedure for a multicomponent separating cascade. As a conclusion, two very powerful simulation procedures have been developed for cascades composed of separating elements whose separation factors are very large. They are applicable in cases where interstage flow rates are input variables for the calculation and stage separation factors are given either as constants or as functions of compositions of the up and down streams. As an application of the new procedure, a computer-aided simulation study has been performed for hydrogen isotope separating cascades by porous membrane method. A cascade system configuration is developed and pertinent design specifications are determined in an example case of the feed conditions and separation requirements. (author)

  17. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams

    Directory of Open Access Journals (Sweden)

    Jaafar Abduo

    2014-01-01

    Full Text Available In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses.

  18. Dosimetric features and kinetic analysis of thermoluminescence from ultra-high molecular weight polyethylene

    Science.gov (United States)

    Chithambo, M. L.

    2012-08-01

    Thermoluminescence (TL) from beta irradiated ultra-high molecular weight polyethylene has been studied for measurements between 30 and 200 °C. An aliquot studied in this work produced TL glow curves consisting of two peaks, the main peak at 88 °C and a weaker intensity peak at 148 °C for heating at 1 °C s-1 following an excitation dose of 215 Gy. The position of the main peak is poorly reproducible for heating rates of 0.2 and 0.6 °C s-1 investigated with the peak position decreasing when the sample is freshly irradiated and the TL re-measured. The said change in peak position is however less of an effect for measurements made at 1 °C s-1 with the peak position being fairly reproducible in this case. Further measurements of the dosimetric properties of ultra-high molecular weight polyethylene showed that its dose response is linear from 26 Gy to about 161 Gy but exhibits slower growth in intensity with dose from about 860 Gy after regions of sub- and supra-linearity in between. If the TL is not measured immediately after irradiation, the signal fades with the delay approximately exponentially. In addition, a number of tests including phosphorescence analysis showed the possibility that the order of kinetics might not be unique but sensitive to several factors including measurement temperature. Thus for instance, the dependence of the peak position on the stop temperature in the partial heating procedure Tm - Tstop implied first-order kinetics but analysis of the geometrical factor μg for the same set of data gave μg = 0.46 ± 0.03 a value corresponding to characteristics somewhat intermediate between first and second order. In comparison, the results of analysis of the phosphorescence recorded at several temperatures on the rising edge of the main peak were only in agreement for measurements at 40 °C with general-order analysis suggesting second-order kinetics apply as did TL-like transformation of the monotonic phosphorescence decay. Both results were

  19. Evolution of facility layout requirements and CAD [computer-aided design] system development

    International Nuclear Information System (INIS)

    Jones, M.

    1990-06-01

    The overall configuration of the Superconducting Super Collider (SSC) including the infrastructure and land boundary requirements were developed using a computer-aided design (CAD) system. The evolution of the facility layout requirements and the use of the CAD system are discussed. The emphasis has been on minimizing the amount of input required and maximizing the speed by which the output may be obtained. The computer system used to store the data is also described

  20. Ten years of CLIVE (Computer-Aided Learning in Veterinary Education) in the United Kingdom.

    Science.gov (United States)

    Dale, Vicki H M; McConnell, Gill; Short, Andrew; Sullivan, Martin

    2005-01-01

    This paper outlines the work of the CLIVE (Computer-Aided Learning in Veterinary Education) project over a 10-year period, set against the backdrop of changes in education policy and learning technology developments. The consortium of six UK veterinary schools and 14 international Associate Member Schools has been very successful. Sustaining these partnerships requires that the project redefine itself and adapt to cater to the diverse learning needs of today's students and to changing professional and societal needs on an international scale.

  1. Computer-aided System of Semantic Text Analysis of a Technical Specification

    OpenAIRE

    Zaboleeva-Zotova, Alla; Orlova, Yulia

    2008-01-01

    The given work is devoted to development of the computer-aided system of semantic text analysis of a technical specification. The purpose of this work is to increase efficiency of software engineering based on automation of semantic text analysis of a technical specification. In work it is offered and investigated the model of the analysis of the text of the technical project is submitted, the attribute grammar of a technical specification, intended for formalization of limited Ru...

  2. APPLICATION OF INFORMATION AND COMMUNICATION TECHNOLOGIES IN COMPUTER AIDED LANGUAGE LEARNING

    Directory of Open Access Journals (Sweden)

    I. B. Tampel

    2013-01-01

    Full Text Available The article deals with the various ways of application for automatic speech recognition, Text-to-Speech technology, pronunciation and communication skills training, vocabulary check of the taught person, audition skills training in computer aided language learning (CALL-system. In spite of some constraints such technologies application is effective both for education problems simplification and for comfort growth of the system application.

  3. Analysis of Computer-Aided and Artificial Intelligence Technologies and Solutions in Service Industries in Russia

    OpenAIRE

    Rezanov, Vladislav

    2013-01-01

    The primary objective of this research study was to investigate the relationship between Computer-Aided and Artificial Intelligence Technologies and customer satisfaction in the context of businesses in Russia. The research focuses on methods of Artificial Intelligence technology application in business and its effect on customer satisfaction. The researcher introduces Artificial Intelligence and studies the forecasting approaches in relation to business operations. The rese...

  4. Creating an Electronic Reference and Information Database for Computer-aided ECM Design

    Science.gov (United States)

    Nekhoroshev, M. V.; Pronichev, N. D.; Smirnov, G. V.

    2018-01-01

    The paper presents a review on electrochemical shaping. An algorithm has been developed to implement a computer shaping model applicable to pulse electrochemical machining. For that purpose, the characteristics of pulse current occurring in electrochemical machining of aviation materials have been studied. Based on integrating the experimental results and comprehensive electrochemical machining process data modeling, a subsystem for computer-aided design of electrochemical machining for gas turbine engine blades has been developed; the subsystem was implemented in the Teamcenter PLM system.

  5. Computer-aided-engineering system for modeling and analysis of ECLSS integration testing

    Science.gov (United States)

    Sepahban, Sonbol

    1987-01-01

    The accurate modeling and analysis of two-phase fluid networks found in environmental control and life support systems is presently undertaken by computer-aided engineering (CAE) techniques whose generalized fluid dynamics package can solve arbitrary flow networks. The CAE system for integrated test bed modeling and analysis will also furnish interfaces and subsystem/test-article mathematical models. Three-dimensional diagrams of the test bed are generated by the system after performing the requisite simulation and analysis.

  6. SINCRO/CAR: An interactive numerical system for computer-aided control engineering and maintenance

    International Nuclear Information System (INIS)

    Zwingelstein, G.; Despujols, A.

    1986-01-01

    This presentation describes a dialogue-oriented software implemented on a portable computer for computer-aided engineering and training in control instrumentation and also for on-line verification of the performances of the analog controllers installed on power plants. The SINCRO/CAR software includes algorithms for controller design, simulation, identification, optimization, frequency response and real time data acquisition. Various results obtained on fossil-fired and nuclear plants are given to illustrate the efficiency of the SINCRO/CAR software

  7. The classification and evaluation of Computer-Aided Software Engineering tools

    OpenAIRE

    Manley, Gary W.

    1990-01-01

    Approved for public release; distribution unlimited. The use of Computer-Aided Software Engineering (CASE) tools has been viewed as a remedy for the software development crisis by achieving improved productivity and system quality via the automation of all or part of the software engineering process. The proliferation and tremendous variety of tools available have stretched the understanding of experienced practitioners and has had a profound impact on the software engineering process itse...

  8. Modelling physics detectors in a computer aided design system for simulation purposes

    International Nuclear Information System (INIS)

    Ahvenainen, J.; Oksakivi, T.; Vuoskoski, J.

    1995-01-01

    The possibility of transferring physics detector models from computer aided design systems into physics simulation packages like GEANT is receiving increasing attention. The problem of exporting detector models constructed in CAD systems into GEANT is well known. We discuss the problem and describe an application, called DDT, which allows one to design detector models in a CAD system and then transfer the models into GEANT for simulation purposes. (orig.)

  9. Basic Principles of Industrial Electric Power Network Computer Aided Design and Engineering

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2012-01-01

    Full Text Available A conceptual model for a computer aided design and engineering system has been developed in the paper. The paper presents basic automation process principles including a graphical representation   network and calculation results, convenient user interface, automatic mode calculation, selection of transformer rated power and cross-section area of wires. The developed algorithm and program make it possible to save time and improve quality of project implementation.

  10. Decomposition recovery extension to the Computer Aided Prototyping System (CAPS) change-merge tool.

    OpenAIRE

    Keesling, William Ronald

    1997-01-01

    Approved for public release; distribution is unlimited A promising use of Computer Aided Prototyping System (CAPS) is to support concurrent design. Key to success in this context is the ability to automatically and reliably combine and integrate the prototypes produced in concurrent efforts. Thus, to be of practical use in this as well as most prototyping contexts, a CAPS tool must have a fast, automated, reliable prototype integration capability. The current CAPS Change Merge Tool is fast...

  11. Integrating aerodynamic surface modeling for computational fluid dynamics with computer aided structural analysis, design, and manufacturing

    Science.gov (United States)

    Thorp, Scott A.

    1992-01-01

    This presentation will discuss the development of a NASA Geometry Exchange Specification for transferring aerodynamic surface geometry between LeRC systems and grid generation software used for computational fluid dynamics research. The proposed specification is based on a subset of the Initial Graphics Exchange Specification (IGES). The presentation will include discussion of how the NASA-IGES standard will accommodate improved computer aided design inspection methods and reverse engineering techniques currently being developed. The presentation is in viewgraph format.

  12. The effects of computer-aided design software on engineering students' spatial visualisation skills

    Science.gov (United States)

    Kösa, Temel; Karakuş, Fatih

    2018-03-01

    The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations (PSVT:R) for both the pre- and the post-test. The participants were 116 freshman students in the first year of their undergraduate programme in the Department of Mechanical Engineering at a university in Turkey. A total of 72 students comprised the experimental group; they were instructed with CAD-based activities in an engineering drawing course. The control group consisted of 44 students who did not attend this course. The results of the study showed that a CAD-based engineering drawing course had a positive effect on developing engineering students' spatial visualisation skills. Additionally, the results of the study showed that spatial visualisation skills can be a predictor for success in a computer-aided engineering drawing course.

  13. Unit cell-based computer-aided manufacturing system for tissue engineering

    International Nuclear Information System (INIS)

    Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo

    2012-01-01

    Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering. (paper)

  14. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  15. A novel technique for presurgical nasoalveolar molding using computer-aided reverse engineering and rapid prototyping.

    Science.gov (United States)

    Yu, Quan; Gong, Xin; Wang, Guo-Min; Yu, Zhe-Yuan; Qian, Yu-Fen; Shen, Gang

    2011-01-01

    To establish a new method of presurgical nasoalveolar molding (NAM) using computer-aided reverse engineering and rapid prototyping technique in infants with unilateral cleft lip and palate (UCLP). Five infants (2 males and 3 females with mean age of 1.2 w) with complete UCLP were recruited. All patients were subjected to NAM before the cleft lip repair. The upper denture casts were recorded using a three-dimensional laser scanner within 2 weeks after birth in UCLP infants. A digital model was constructed and analyzed to simulate the NAM procedure with reverse engineering software. The digital geometrical data were exported to print the solid model with rapid prototyping system. The whole set of appliances was fabricated based on these solid models. Laser scanning and digital model construction simplified the NAM procedure and estimated the treatment objective. The appliances were fabricated based on the rapid prototyping technique, and for each patient, the complete set of appliances could be obtained at one time. By the end of presurgical NAM treatment, the cleft was narrowed, and the malformation of nasoalveolar segments was aligned normally. We have developed a novel technique of presurgical NAM based on a computer-aided design. The accurate digital denture model of UCLP infants could be obtained with laser scanning. The treatment design and appliance fabrication could be simplified with a computer-aided reverse engineering and rapid prototyping technique.

  16. [Three-dimensional computer aided design for individualized post-and-core restoration].

    Science.gov (United States)

    Gu, Xiao-yu; Wang, Ya-ping; Wang, Yong; Lü, Pei-jun

    2009-10-01

    To develop a method of three-dimensional computer aided design (CAD) of post-and-core restoration. Two plaster casts with extracted natural teeth were used in this study. The extracted teeth were prepared and scanned using tomography method to obtain three-dimensional digitalized models. According to the basic rules of post-and-core design, posts, cores and cavity surfaces of the teeth were designed using the tools for processing point clouds, curves and surfaces on the forward engineering software of Tanglong prosthodontic system. Then three-dimensional figures of the final restorations were corrected according to the configurations of anterior teeth, premolars and molars respectively. Computer aided design of 14 post-and-core restorations were finished, and good fitness between the restoration and the three-dimensional digital models were obtained. Appropriate retention forms and enough spaces for the full crown restorations can be obtained through this method. The CAD of three-dimensional figures of the post-and-core restorations can fulfill clinical requirements. Therefore they can be used in computer-aided manufacture (CAM) of post-and-core restorations.

  17. Unit cell-based computer-aided manufacturing system for tissue engineering.

    Science.gov (United States)

    Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo

    2012-03-01

    Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering.

  18. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  19. Computer-aided navigation in dental implantology: 7 years of clinical experience.

    Science.gov (United States)

    Ewers, Rolf; Schicho, Kurt; Truppe, Michael; Seemann, Rudolf; Reichwein, Astrid; Figl, Michael; Wagner, Arne

    2004-03-01

    This long-term study gives a review over 7 years of research, development, and routine clinical application of computer-aided navigation technology in dental implantology. Benefits and disadvantages of up-to-date technologies are discussed. In the course of the current advancement, various hardware and software configurations are used. In the initial phase, universally applicable navigation software is adapted for implantology. Since 2001, a special software module for dental implantology is available. Preoperative planning is performed on the basis of prosthetic aspects and requirements. In clinical routine use, patient and drill positions are intraoperatively registered by means of optoelectronic tracking systems; during preclinical tests, electromagnetic trackers are also used. In 7 years (1995 to 2002), 55 patients with 327 dental implants were successfully positioned with computer-aided navigation technology. The mean number of implants per patient was 6 (minimum, 1; maximum, 11). No complications were observed; the preoperative planning could be exactly realized. The average expenditure of time for the preparation of a surgical intervention with navigation decreased from 2 to 3 days in the initial phase to one-half day in clinical routine use with software that is optimized for dental implantology. The use of computer-aided navigation technology can contribute to considerable quality improvement. Preoperative planning is exactly realized and intraoperative safety is increased, because damage to nerves or neighboring teeth can be avoided.

  20. Structural features and kinetic characterization of alanine racemase from Bacillus pseudofirmus OF4.

    Science.gov (United States)

    Dong, Hui; Hu, Tingting; He, Guangzheng; Lu, Deren; Qi, Jianxun; Dou, Yanshu; Long, Wei; He, Xin; Ju, Jiansong; Su, Dan

    2018-02-26

    Alanine racemase (Alr) is a pyridoxal-5'-phosphate-dependent (PLP) enzyme that catalyzes a reversible racemization between the enantiomers of alanine. d-Alanine is an indispensable constituent in the biosynthesis of bacterial cell-wall peptidoglycan, and its inhibition is lethal to prokaryotes, which makes it an attractive target for designing antibacterial drugs. In this study, the molecular structure of alanine racemase from Bacillus pseudofirmus OF4 (DadX OF4 ) was determined by X-ray crystallography to a resolution of 1.8 Å. The comparison of DadX OF4 with alanine racemases from other bacteria demonstrated a conserved overall fold. Enzyme kinetics analysis showed that the conserved residues at the substrate entryway and the salt bridge at the dimer interface are critical for enzyme activity. These structural and biochemical findings provide a template for future structure-based drug-development efforts targeting alanine racemases. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Computer-aided diagnostic system for detection of Hashimoto thyroiditis on ultrasound images from a Polish population.

    Science.gov (United States)

    Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S

    2014-02-01

    Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.

  2. Kinetic features of metal complexes with polysaccharide colloids: Impact of ionic strength

    NARCIS (Netherlands)

    Roturea, E.; Leeuwen, van H.P.

    2009-01-01

    The dynamic features of metal binding by a gel-like polysaccharide, carboxymethyldextran (CMD), are investigated by stripping chronopotentiometry (SCP). This technique measures the diffusive flux properties of the metallic species in the ligand dispersion as defined by their concentration, mobility,

  3. Influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin.

    Science.gov (United States)

    Poggio, Claudio; Pigozzo, Marco; Ceci, Matteo; Scribante, Andrea; Beltrami, Riccardo; Chiesa, Marco

    2016-01-01

    The purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (CAD/CAM) resin nanoceramic (RNC) material to dentin. In this in vitro study, 30 disks were milled from RNC blocks (Lava Ultimate/3M ESPE) with CAD/CAM technology. The disks were subsequently cemented to the exposed dentin of 30 recently extracted bovine permanent mandibular incisors. The specimens were randomly assigned into 3 groups of 10 teeth each. In Group 1, disks were cemented using a total-etch protocol (Scotchbond™ Universal Etchant phosphoric acid + Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 2, disks were cemented using a self-etch protocol (Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 3, disks were cemented using a self-adhesive protocol (RelyX™ Unicem 2 Automix self-adhesive resin cement). All cemented specimens were placed in a universal testing machine (Instron Universal Testing Machine 3343) and submitted to a shear bond strength test to check the strength of adhesion between the two substrates, dentin, and RNC disks. Specimens were stressed at a crosshead speed of 1 mm/min. Data were analyzed with analysis of variance and post-hoc Tukey's test at a level of significance of 0.05. Post-hoc Tukey testing showed that the highest shear strength values (P adhesives) showed better shear strength values compared to self-adhesive resin cements. Furthermore, conventional resin cements used together with a self-etch adhesive reported the highest values of adhesion.

  4. Effect of resin coating and occlusal loading on microleakage of Class II computer-aided design/computer-aided manufacturing fabricated ceramic restorations: a confocal microscopic study.

    Science.gov (United States)

    Kitayama, Shuzo; Nasser, Nasser A; Pilecki, Peter; Wilson, Ron F; Nikaido, Toru; Tagami, Junji; Watson, Timothy F; Foxton, Richard M

    2011-05-01

    To evaluate the effect of resin coating and occlusal loading on microleakage of class II computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic restorations. Molars were prepared for an mesio-occlusal-distal (MOD) inlay and were divided into two groups: non-coated (controls); and resin-coated, in which the cavity was coated with a combination of a dentin bonding system (Clearfil Protect Bond) and a flowable resin composite (Clearfil Majesty Flow). Ceramic inlays were fabricated using the CAD/CAM technique (CEREC 3) and cemented with resin cement (Clearfil Esthetic Cement). After 24 h of water storage, the restored teeth in each group were divided into two subgroups: unloaded or loaded with an axial force of 80 N at a rate of 2.5 cycles/s for 250,000 cycles while stored in water. After immersion in 0.25% Rhodamine B solution, the teeth were sectioned bucco-lingually at the mesial and distal boxes. Tandem scanning confocal microscopy (TSM) was used for evaluation of microleakage. The locations of the measurements were assigned to the cavity walls and floor. Loading did not have a significant effect on microleakage in either the resin-coated or non-coated group. Resin coating significantly reduced microleakage regardless of loading. The cavity floor exhibited greater microleakage compared to the cavity wall. TSM observation also revealed that microleakage at the enamel surface was minimal regardless of resin coating. In contrast, non-coated dentin showed extensive leakage, whereas resin-coated dentin showed decreased leakage. Resin coating with a combination of a dentin-bonding system and a flowable resin composite may be indicated prior to impression-taking when restoring teeth with CAD/CAM ceramic inlays in order to reduce microleakage at the tooth-resin interface.

  5. Evaluation of the fracture resistance of computer-aided design/computer-aided manufacturing monolithic crowns prepared in different cement thicknesses.

    Science.gov (United States)

    Sagsoz, N Polat; Yanıkoglu, N

    2018-04-01

    The purpose of this study was to evaluate the fracture resistance of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) crowns that are prepared with different cement thickness. For this investigation, a human maxillary premolar tooth was selected. Master model preparation was performed with a demand bur under water spray. Master die was taken to fabricate 105 epoxy resin replicas. The crowns were milled using a CEREC 4 CAD/CAM system (Software Version, 4.2.0.57192). CAD/CAM crowns were made using resin nanoceramic, feldspathic glass ceramic, lithium disilicate, and leucite-reinforced ceramics. Each group was subdivided into three groups in accordance with three different cement thicknesses (30, 90, and 150 μm). Crowns milled out. Then RelyX ™ U200 was used as a luting agent to bond the crowns to the prepared samples. After one hour cementations, the specimens were stored in water bath at 37°C for 1 week before testing. Seven unprepared and unrestored teeth were kept and tested as a control group. A universal test machine was used to assume the fracture resistance of all specimens. The compressive load (N) that caused fracture was recorded for each specimen. Fracture resistance data were statistically analyzed by one-way ANOVA and two-factor interaction modeling test (α = 0.001). There are statistically significant differences between fracture resistances of CAD/CAM monolithic crown materials (P cement thickness is not statistically significant for fracture resistance of CAD/CAM monolithic crowns (P > 0.001). CAD/CAM monolithic crown materials affected fracture resistance. Cement thickness (30, 90, and 150 μm) was not effective on fracture resistance of CAD/CAM monolithic crowns.

  6. Shear bond strength of computer-aided design and computer-aided manufacturing feldspathic and nano resin ceramics blocks cemented with three different generations of resin cement.

    Science.gov (United States)

    Ab-Ghani, Zuryati; Jaafar, Wahyuni; Foo, Siew Fon; Ariffin, Zaihan; Mohamad, Dasmawati

    2015-01-01

    To evaluate the shear bond strength between the dentin substrate and computer-aided design and computer-aided manufacturing feldspathic ceramic and nano resin ceramics blocks cemented with resin cement. Sixty cuboidal blocks (5 mm × 5 mm × 5 mm) were fabricated in equal numbers from feldspathic ceramic CEREC(®) Blocs PC and nano resin ceramic Lava™ Ultimate, and randomly divided into six groups (n = 10). Each block was cemented to the dentin of 60 extracted human premolar using Variolink(®) II/Syntac Classic (multi-steps etch-and-rinse adhesive bonding), NX3 Nexus(®) (two-steps etch-and-rinse adhesive bonding) and RelyX™ U200 self-adhesive cement. All specimens were thermocycled, and shear bond strength testing was done using the universal testing machine at a crosshead speed of 1.0 mm/min. Data were analyzed using one-way ANOVA. Combination of CEREC(®) Blocs PC and Variolink(®) II showed the highest mean shear bond strength (8.71 Mpa), while the lowest of 2.06 Mpa were observed in Lava™ Ultimate and RelyX™ U200. There was no significant difference in the mean shear bond strength between different blocks. Variolink(®) II cement using multi-steps etch-and-rinse adhesive bonding provided a higher shear bond strength than the self-adhesive cement RelyX U200. The shear bond strength was not affected by the type of blocks used.

  7. Secondary Maxillary and Orbital Floor Reconstruction With a Free Scapular Flap Using Cutting and Fixation Guides Created by Computer-Aided Design/Computer-Aided Manufacturing.

    Science.gov (United States)

    Morita, Daiki; Numajiri, Toshiaki; Tsujiko, Shoko; Nakamura, Hiroko; Yamochi, Ryo; Sowa, Yoshihiro; Yasuda, Makoto; Hirano, Shigeru

    2017-11-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2 mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.

  8. [Evaluation of production and clinical working time of computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays for complete denture].

    Science.gov (United States)

    Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X

    2017-02-18

    To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (Pmanufacture custom trays by three-dimensional printing method, there is no need to pour preliminary cast after taking the primary impression, therefore, it can save the impression material and model material. As to completing denture restoration, manufacturing custom trays using FSD system is worth being

  9. Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeoung Hyun [Dept. of Radiology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Cha, Joo Hee; Kim, Nam Kug; Chang, Young Jun; Kim, Hak Hee [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ko, Myung Su [Health Screening and Promotion Center, Asan Medical Center, Seoul (Korea, Republic of); Choi, Young Wook [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2014-04-15

    The aim of this study was to evaluate the performance of a proposed computer-aided detection (CAD) system in automated breast ultrasonography (ABUS). Eighty-nine two-dimensional images (20 cysts, 42 benign lesions, and 27 malignant lesions) were obtained from 47 patients who underwent ABUS (ACUSON S2000). After boundary detection and removal, we detected mass candidates by using the proposed adjusted Otsu's threshold; the threshold was adaptive to the variations of pixel intensities in an image. Then, the detected candidates were segmented. Features of the segmented objects were extracted and used for training/testing in the classification. In our study, a support vector machine classifier was adopted. Eighteen features were used to determine whether the candidates were true lesions or not. A five-fold cross validation was repeated 20 times for the performance evaluation. The sensitivity and the false positive rate per image were calculated, and the classification accuracy was evaluated for each feature. In the classification step, the sensitivity of the proposed CAD system was 82.67% (SD, 0.02%). The false positive rate was 0.26 per image. In the detection/segmentation step, the sensitivities for benign and malignant mass detection were 90.47% (38/42) and 92.59% (25/27), respectively. In the five-fold cross-validation, the standard deviation of pixel intensities for the mass candidates was the most frequently selected feature, followed by the vertical position of the centroids. In the univariate analysis, each feature had 50% or higher accuracy. The proposed CAD system can be used for lesion detection in ABUS and may be useful in improving the screening efficiency.

  10. A new approach to develop computer-aided diagnosis scheme of breast mass classification using deep learning technology.

    Science.gov (United States)

    Qiu, Yuchen; Yan, Shiju; Gundreddy, Rohith Reddy; Wang, Yunzhi; Cheng, Samuel; Liu, Hong; Zheng, Bin

    2017-01-01

    To develop and test a deep learning based computer-aided diagnosis (CAD) scheme of mammograms for classifying between malignant and benign masses. An image dataset involving 560 regions of interest (ROIs) extracted from digital mammograms was used. After down-sampling each ROI from 512×512 to 64×64 pixel size, we applied an 8 layer deep learning network that involves 3 pairs of convolution-max-pooling layers for automatic feature extraction and a multiple layer perceptron (MLP) classifier for feature categorization to process ROIs. The 3 pairs of convolution layers contain 20, 10, and 5 feature maps, respectively. Each convolution layer is connected with a max-pooling layer to improve the feature robustness. The output of the sixth layer is fully connected with a MLP classifier, which is composed of one hidden layer and one logistic regression layer. The network then generates a classification score to predict the likelihood of ROI depicting a malignant mass. A four-fold cross validation method was applied to train and test this deep learning network. The results revealed that this CAD scheme yields an area under the receiver operation characteristic curve (AUC) of 0.696±0.044, 0.802±0.037, 0.836±0.036, and 0.822±0.035 for fold 1 to 4 testing datasets, respectively. The overall AUC of the entire dataset is 0.790±0.019. This study demonstrates the feasibility of applying a deep learning based CAD scheme to classify between malignant and benign breast masses without a lesion segmentation, image feature computation and selection process.

  11. A New Approach to Develop Computer-aided Diagnosis Scheme of Breast Mass Classification Using Deep Learning Technology

    Science.gov (United States)

    Qiu, Yuchen; Yan, Shiju; Gundreddy, Rohith Reddy; Wang, Yunzhi; Cheng, Samuel; Liu, Hong; Zheng, Bin

    2017-01-01

    PURPOSE To develop and test a deep learning based computer-aided diagnosis (CAD) scheme of mammograms for classifying between malignant and benign masses. METHODS An image dataset involving 560 regions of interest (ROIs) extracted from digital mammograms was used. After down-sampling each ROI from 512×512 to 64×64 pixel size, we applied an 8 layer deep learning network that involves 3 pairs of convolution-max-pooling layers for automatic feature extraction and a multiple layer perceptron (MLP) classifier for feature categorization to process ROIs. The 3 pairs of convolution layers contain 20, 10, and 5 feature maps, respectively. Each convolution layer is connected with a max-pooling layer to improve the feature robustness. The output of the sixth layer is fully connected with a MLP classifier, which is composed of one hidden layer and one logistic regression layer. The network then generates a classification score to predict the likelihood of ROI depicting a malignant mass. A four-fold cross validation method was applied to train and test this deep learning network. RESULTS The results revealed that this CAD scheme yields an area under the receiver operation characteristic curve (AUC) of 0.696±0.044, 0.802±0.037, 0.836±0.036, and 0.822±0.035 for fold 1 to 4 testing datasets, respectively. The overall AUC of the entire dataset is 0.790±0.019. CONCLUSIONS This study demonstrates the feasibility of applying a deep learning based CAD scheme to classify between malignant and benign breast masses without a lesion segmentation, image feature computation and selection process. PMID:28436410

  12. Prosthetic rehabilitation with an implant-supported fixed prosthesis using computer-aided design and computer-aided manufacturing dental technology for a patient with a mandibulectomy: A clinical report.

    Science.gov (United States)

    Yoon, Hyung-In; Han, Jung-Suk

    2016-02-01

    The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Kinetic features and non-stationary electron trapping in paraxial magnetic nozzles

    Science.gov (United States)

    Sánchez-Arriaga, G.; Zhou, J.; Ahedo, E.; Martínez-Sánchez, M.; Ramos, J. J.

    2018-03-01

    The paraxial expansion of a collisionless plasma jet into vacuum, guided by a magnetic nozzle, is studied with an Eulerian and non-stationary Vlasov-Poisson solver. Parametric analyzes varying the magnetic field expansion rate, the size of the simulation box, and the electrostatic potential fall are presented. After choosing the potential fall leading to a zero net current beam, the steady states of the simulations exhibit a quasi-neutral region followed by a downstream sheath. The latter, an unavoidable consequence of the finite size of the computational domain, does not affect the quasi-neutral region if the box size is chosen appropriately. The steady state presents a strong decay of the perpendicular temperature of the electrons, whose profile versus the inverse of the magnetic field does not depend on the expansion rate within the quasi-neutral region. As a consequence, the electron distribution function is highly anisotropic downstream. The simulations revealed that the ions reach a higher velocity during the transient than in the steady state and their distribution functions are not far from mono-energetic. The density percentage of the population of electrons trapped during the transient, which is computed self-consistently by the code, is up to 25% of the total electron density in the quasi-neutral region. It is demonstrated that the exact amount depends on the history of the system and the steady state is not unique. Nevertheless, the amount of trapped electrons is smaller than the one assumed heuristically by kinetic stationary theories.

  14. Computer-aided dispatch--traffic management center field operational test final detailed test plan : WSDOT deployment

    Science.gov (United States)

    2003-10-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...

  15. Computer-aided dispatch--traffic management center field operational test final test plans : state of Utah

    Science.gov (United States)

    2004-01-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...

  16. A PC Mathcad-based computational aid for severe accident analysis and its application to a BWR small LOCA sequence

    International Nuclear Information System (INIS)

    Wu, Laung-Kuang T.; Lee, S.J.

    2004-01-01

    A PC-based Mathcad program is used to develop a computational aid for analyzing severe accident phenomena. This computational aid uses simple engineering expressions and empirical correlations to estimate key quantities and timings at various stages of accident progressions. In this paper, the computational aid is applied to analyze an early phase of a BWR small LOCA sequence. The accident phenomena analyzed include: break flow rates, boiled-up water level in the core, core uncovery time, depressurization of the reactor pressure vessel, core heat-up, onset of clad oxidation, hydrogen generation, and onset of fuel relocation. The results are compared with those obtained running the MAAP 3.0B code. This PC-based computational aid can be used to train plant personnel in understanding severe accident phenomena and to assist them in managing severe accidents. (author)

  17. Kinetic and Thermodynamic Features Reveal That E. coli BCP Is an Unusually Versatile Peroxiredoxin†

    Science.gov (United States)

    Reeves, Stacy A.; Parsonage, Derek; Nelson, Kimberly J.; Poole, Leslie B.

    2011-01-01

    In Escherichia coli, bacterioferritin-comigratory protein (BCP) is a peroxiredoxin (Prx) which catalyzes the reduction of H2O2 and organic hydroperoxides. This protein, along with plant PrxQ, is a founding member of one of the least studied subfamilies of Prxs. Recent structural data have suggested that proteins in the BCP/PrxQ group can exist as monomers or dimers; we report here that, by analytical ultracentrifugation, both oxidized and reduced E. coli BCP behave as monomers in solution at concentrations as high as 200 µM. Unexpectedly, thioredoxin (Trx1)-dependent peroxidase assays conducted by stopped flow spectroscopy demonstrated that Vmax,app increases with increasing Trx1 concentrations, indicating a nonsaturable interaction (Km > 100 µM). At a physiologically reasonable Trx1 concentration of 10 µM, the apparent Km value for H2O2 is ~80 µM, and overall Vmax/Km for H2O2, which remains constant over the various Trx1 concentrations (consistent with a ping-pong mechanism), is about 1.3 × 104 M−1 s−1. Our kinetic analyses demonstrated that BCP can utilize a variety of reducing substrates, including Trx1, Trx2, Grx1 and Grx3. BCP exhibited a high redox potential of −145.9 ± 3.2 mV, the highest to date observed for a Prx. Moreover, BCP exhibited a broad peroxide specificity, with comparable rates for H2O2 and cumene hydroperoxide. We determined a pKa of ~5.8 for the peroxidatic cysteine (Cys45) using both spectroscopic and activity titration data. These findings support an important role for BCP in interacting with multiple substrates and remaining active under highly oxidizing cellular conditions, potentially serving as a defense enzyme of last resort. PMID:21910476

  18. Computer-aided design of the RF-cavity for a high-power S-band klystron

    Science.gov (United States)

    Kant, D.; Bandyopadhyay, A. K.; Pal, D.; Meena, R.; Nangru, S. C.; Joshi, L. M.

    2012-08-01

    This article describes the computer-aided design of the RF-cavity for a S-band klystron operating at 2856 MHz. State-of-the-art electromagnetic simulation tools SUPERFISH, CST Microwave studio, HFSS and MAGIC have been used for cavity design. After finalising the geometrical details of the cavity through simulation, it has been fabricated and characterised through cold testing. Detailed results of the computer-aided simulation and cold measurements are presented in this article.

  19. A new computer aided diagnosis system for evaluation of chronic liver disease with ultrasound shear wave elastography imaging.

    Science.gov (United States)

    Gatos, Ilias; Tsantis, Stavros; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Theotokas, Ioannis; Zoumpoulis, Pavlos; Loupas, Thanasis; Hazle, John D; Kagadis, George C

    2016-03-01

    Classify chronic liver disease (CLD) from ultrasound shear-wave elastography (SWE) imaging by means of a computer aided diagnosis (CAD) system. The proposed algorithm employs an inverse mapping technique (red-green-blue to stiffness) to quantify 85 SWE images (54 healthy and 31 with CLD). Texture analysis is then applied involving the automatic calculation of 330 first and second order textural features from every transformed stiffness value map to determine functional features that characterize liver elasticity and describe liver condition for all available stages. Consequently, a stepwise regression analysis feature selection procedure is utilized toward a reduced feature subset that is fed into the support vector machines (SVMs) classification algorithm in the design of the CAD system. With regard to the mapping procedure accuracy, the stiffness map values had an average difference of 0.01 ± 0.001 kPa compared to the quantification results derived from the color-box provided by the built-in software of the ultrasound system. Highest classification accuracy from the SVM model was 87.0% with sensitivity and specificity values of 83.3% and 89.1%, respectively. Receiver operating characteristic curves analysis gave an area under the curve value of 0.85 with [0.77-0.89] confidence interval. The proposed CAD system employing color to stiffness mapping and classification algorithms offered superior results, comparing the already published clinical studies. It could prove to be of value to physicians improving the diagnostic accuracy of CLD and can be employed as a second opinion tool for avoiding unnecessary invasive procedures.

  20. Computer-aided interpretation of dynamic magnetic resonance imaging reflects histopathology of invasive breast cancer

    International Nuclear Information System (INIS)

    Baltzer, Pascal A.T.; Vag, Tibor; Dietzel, Matthias; Beger, Sebastian; Freiberg, Christian; Kaiser, Werner A.; Gajda, Mieczyslaw; Camara, Oumar

    2010-01-01

    To perform a semiautomated software-based comparison of invasive breast carcinoma dynamic enhancement patterns in MR mammography with histological prognostic factors considering whole lesion volumes. A total of 128 patients with 145 invasive breast carcinomas underwent dynamic MR mammography. Kinetic features from the invasive breast lesions were obtained using commercially available software to automatically assess volume enhancement characteristics of a manually chosen lesion. Findings were compared with histological factors determining tumour aggressiveness (lymph node status, LN; oestrogen/progesterone receptor (ER/PR) status; HER-2/neu status; tumour grade) by using nonparametric rank tests and binary logistic regression analysis (BLRA). Volume enhancement characteristics were significantly influenced by LN, ER/PR and HER-2/neu status (P<0.05). BLRA implied that total lesion and plateau voxel volume were independent predictors of ER/PR and HER-2/neu status. Strongest initial enhancement predicted negative ER/PR, and time to peak of the most suspect curve was inversely correlated with positive LN status. On the other hand, no statistical significance could be observed between histological tumour grading and kinetic features. Histopathological criteria associated with poor prognosis lead to significantly more aggressive dynamic enhancement patterns in MR mammography. In this study, higher lesion volumes as well as higher and earlier initial enhancement were independent covariates predicting higher tumour aggressiveness. (orig.)

  1. Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems.

    Science.gov (United States)

    Park, Jong-Kyoung; Lee, Wan-Sun; Kim, Hae-Young; Kim, Woong-Chul; Kim, Ji-Hwan

    2015-04-01

    To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

  2. Computer-aided diagnosis of leukoencephalopathy in children treated for acute lymphoblastic leukemia

    Science.gov (United States)

    Glass, John O.; Li, Chin-Shang; Helton, Kathleen J.; Reddick, Wilburn E.

    2005-04-01

    The purpose of this study was to use objective quantitative MR imaging methods to develop a computer-aided diagnosis tool to differentiate white matter (WM) hyperintensities as either leukoencephalopathy (LE) or normal maturational processes in children treated for acute lymphoblastic leukemia with intravenous high dose methotrexate. A combined imaging set consisting of T1, T2, PD, and FLAIR MR images and WM, gray matter, and cerebrospinal fluid a priori maps from a spatially normalized atlas were analyzed with a neural network segmentation based on a Kohonen Self-Organizing Map. Segmented regions were manually classified to identify the most hyperintense WM region and the normal appearing genu region. Signal intensity differences normalized to the genu within each examination were generated for two time points in 203 children. An unsupervised hierarchical clustering algorithm with the agglomeration method of McQuitty was used to divide data from the first examination into normal appearing or LE groups. A C-support vector machine (C-SVM) was then trained on the first examination data and used to classify the data from the second examination. The overall accuracy of the computer-aided detection tool was 83.5% (299/358) with sensitivity to normal WM of 86.9% (199/229) and specificity to LE of 77.5% (100/129) when compared to the readings of two expert observers. These results suggest that subtle therapy-induced leukoencephalopathy can be objectively and reproducibly detected in children treated for cancer using this computer-aided detection approach based on relative differences in quantitative signal intensity measures normalized within each examination.

  3. Computer-aided system for diabetes care in Berlin, G.D.R.

    Science.gov (United States)

    Thoelke, H; Meusel, K; Ratzmann, K P

    1990-01-01

    In the Centre of Diabetes and Metabolic Disorders of Berlin, G.D.R., a computer-aided care system has been used since 1974, aiming at relieving physicians and medical staff from routine tasks and rendering possible epidemiological research on an unselected diabetes population of a defined area. The basis of the system is the data bank on diabetics (DB), where at present data from approximately 55,000 patients are stored. DB is used as a diabetes register of Berlin. On the basis of standardised criteria of diagnosis and therapy of diabetes mellitus in our dispensary care system, DB facilitates representative epidemiological analyses of the diabetic population, e.g. prevalence, incidence, duration of diabetes, and modes of treatment. The availability of general data on the population or the selection of specified groups of patients serves the management of the care system. Also, it supports the computer-aided recall of type II diabetics, treated either with diet alone or with diet and oral drugs. In this way, the standardised evaluation of treatment strategies in large populations of diabetics is possible on the basis of uniform metabolic criteria (blood glucose plus urinary glucose). The system consists of a main computer in the data processing unit and of personal computers in the diabetes centre which can be used either individually or as terminals to the main computer. During 14 years of experience, the computer-aided out-patient care of type II diabetics has proved efficient in a big-city area with a large population.

  4. Comparison of 3D computer-aided with manual cerebral aneurysm measurements in different imaging modalities

    International Nuclear Information System (INIS)

    Groth, M.; Buhk, J.H.; Schoenfeld, M.; Goebell, E.; Fiehler, J.; Forkert, N.D.

    2013-01-01

    To compare intra- and inter-observer reliability of aneurysm measurements obtained by a 3D computer-aided technique with standard manual aneurysm measurements in different imaging modalities. A total of 21 patients with 29 cerebral aneurysms were studied. All patients underwent digital subtraction angiography (DSA), contrast-enhanced (CE-MRA) and time-of-flight magnetic resonance angiography (TOF-MRA). Aneurysm neck and depth diameters were manually measured by two observers in each modality. Additionally, semi-automatic computer-aided diameter measurements were performed using 3D vessel surface models derived from CE- (CE-com) and TOF-MRA (TOF-com) datasets. Bland-Altman analysis (BA) and intra-class correlation coefficient (ICC) were used to evaluate intra- and inter-observer agreement. BA revealed the narrowest relative limits of intra- and inter-observer agreement for aneurysm neck and depth diameters obtained by TOF-com (ranging between ±5.3 % and ±28.3 %) and CE-com (ranging between ±23.3 % and ±38.1 %). Direct measurements in DSA, TOF-MRA and CE-MRA showed considerably wider limits of agreement. The highest ICCs were observed for TOF-com and CE-com (ICC values, 0.92 or higher for intra- as well as inter-observer reliability). Computer-aided aneurysm measurement in 3D offers improved intra- and inter-observer reliability and a reproducible parameter extraction, which may be used in clinical routine and as objective surrogate end-points in clinical trials. (orig.)

  5. Remineralization potential of nano-hydroxyapatite on enamel and cementum surrounding margin of computer-aided design and computer-aided manufacturing ceramic restoration

    Science.gov (United States)

    Juntavee, Niwut; Juntavee, Apa; Plongniras, Preeyarat

    2018-01-01

    Objective This study investigates the effects of nano-hydroxyapatite (NHA) gel and Clinpro (CP) on remineralization potential of enamel and cementum at the cavosurface area of computer-aided design and computer-aided manufacturing ceramic restoration. Materials and methods Thirty extracted human mandibular third molars were sectioned at 1 mm above and below the cemento–enamel junction to remove the cemento–enamel junction portions and replaced them with zirconia ceramic disks by bonding them to the crown and root portions with resin cement. The enamel and cementum with an area of 4×4 mm2 surrounding the ceramic disk was demineralized with carbopol. The demineralized surfaces were treated with either NHA or CP, while 1 group was left with no treatment. Vickers microhardness of enamel and cementum were determined before demineralization, after demineralization, and after remineralization. Analysis of variance and Tukey multiple comparisons were used to determine statistically significant differences at 95% level of confidence. Scanning electron microscopy and X-ray diffraction were used to evaluate for surface alterations. Results The mean ± SD of Vickers microhardness for before demineralization, after demineralization, and after remineralization for enamel and cementum were 377.37±22.99, 161.95±10.54, 161.70±5.92 and 60.37±3.81, 17.65±0.91, 17.04±1.00 for the no treatment group; 378.20±18.76, 160.72±8.38, 200.08±8.29 and 62.58±3.37, 18.38±1.33, 27.99±2.68 for the NHA groups; and 380.53±25.14, 161.94±5.66, 193.16±7.54 and 62.78±4.75, 19.07±1.30, 24.46±2.02 for the CP groups. Analysis of variance indicated significant increase in microhardness of demineralized enamel and cementum upon the application of either NHA or CP (pmanufacturing ceramic. PMID:29780246

  6. Influences of Light-emitting Diode Illumination Bleaching Technique on Nanohardness of Computer-aided Design and Computer-aided Manufacturing Ceramic Restorative Materials.

    Science.gov (United States)

    Juntavee, Niwut; Juntavee, Apa; Saensutthawijit, Phuwiwat

    2018-02-01

    This study evaluated the effect of light-emitting diode (LED) illumination bleaching technique on the surface nanohardness of various computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic materials. Twenty disk-shaped samples (width, length, and thickness = 10, 15, and 2 mm) were prepared from each of the ceramic materials for CAD/CAM, including Lava™ Ultimate (L V ), Vita Enamic® (E n ) IPS e.max® CAD (M e ), inCoris® TZI (I C ), and Prettau® zirconia (P r ). The samples from each type of ceramic were randomly divided into two groups based on the different bleaching techniques to be used on them, using 35% hydrogen peroxide with and without LED illumination. The ceramic disk samples were bleached according to the manufacturer's instruction. Surface hardness test was performed before and after bleaching using nanohardness tester with a Berkovich diamond indenter. The respective Vickers hardness number upon no bleaching and bleaching without or with LED illumination [mean ± standard deviation (SD)] for each type of ceramic were as follows: 102.52 ± 2.09, 101.04 ± 1.18, and 98.17 ± 1.15 for L V groups; 274.96 ± 5.41, 271.29 ± 5.94, and 268.20 ± 7.02 for E n groups; 640.74 ± 31.02, 631.70 ± 22.38, and 582.32 ± 33.88 for M e groups; 1,442.09 ± 35.07, 1,431.32 ± 28.80, and 1,336.51 ± 34.03 for I C groups; and 1,383.82 ± 33.87, 1,343.51 ± 38.75, and 1,295.96 ± 31.29 for P r groups. The results indicated surface hardness reduction following the bleaching procedure of varying degrees for different ceramic materials. Analysis of variance (ANOVA) revealed a significant reduction in surface hardness due to the effect of bleaching technique, ceramic material, and the interaction between bleaching technique and ceramic material (p LED illumination exhibited more reduction in surface hardness of dental ceramic than what was observed without LED illumination. Clinicians should consider protection of the existing restoration while bleaching.

  7. [Initial evolution research for design and process accuracy of one type of domestic computer aided design soft and computer aided manufacture].

    Science.gov (United States)

    Song, Yang; Zhao, Yi-jiao; Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2013-09-01

    To evaluate the design and manufacture accuracy of a domestic computer aided design (CAD) and computer aided manufacture (CAM) system, and to compare it with similar foreign products. Thirty models of posterior-teeth-single-crown preparations were collected, and STL data of these preparations was collected by Denmark 3Shape scanner. Three copings were made for each preparation, the one designed and manufactured using commercial CAD/CAM system (3Shape CAD software and Wieland T1 CAM equipment) was assigned into control group T0, the one designed and manufactured using domestic CAD software (developed by Peking University School and Hospital of Stomatology and Nanjing University of Aeronautics and Astronautics) and Wieland T1 CAM equipment was assigned into experimental group TCAD for design accuracy evaluation, and the one designed and manufactured using 3Shape CAD software and domestic CAM equipment (developed by Peking University School and Hospital of Stomatology, Tsinghua University and ShanDong XinHua Incorporated Company of medical apparatus and instruments) was assigned into experimental group TCAM for manufacture accuracy evaluation. Finally, the marginal fitness were compared and evaluated by using 3D & Profile measurement microscope laser. The marginal fitness of TCAD was 27.98 (19.10, 46.57) µm in buccal, 32.67 (20.65, 50.82) µm in lingual, 27.38 (22.53, 52.61) µm in mesial, 29.50 (22.68, 53.65) µm in distal; of TCAM was 21.69 (15.87, 30.21) µm in buccal, 18.51 (13.50, 22.51) µm in lingual, 19.15 (15.42, 26.89) µm in mesial, 22.77 (18.58, 32.15) µm in distal; and there were no statistical differences compared with T0 [20.16 (17.16, 48.00) µm in buccal, 21.51 (17.05, 28.31) µm in lingual, 23.54 (17.89, 30.04) µm in mesial and 23.94 (17.93, 28.19) µm in distal] except lingual data of TCAD. The design and machining precision of this domestic CAD/CAM system is at the same level of those comparable foreign products.

  8. On the integration of computer aided design and analysis using the finite element absolute nodal coordinate formulation

    International Nuclear Information System (INIS)

    Sanborn, Graham G.; Shabana, Ahmed A.

    2009-01-01

    For almost a decade, the finite element absolute nodal coordinate formulation (ANCF) has been used for both geometry and finite element representations. Because of the ANCF isoparametric property in the cases of beams, plates and shells, ANCF finite elements lend themselves easily to the geometric description of curves and surfaces, as demonstrated in the literature. The ANCF finite elements, therefore, are ideal for what is called isogeometric analysis that aims at the integration ofcomputer aided designandanalysis (ICADA), which involves the integration of what is now split into the separate fields of computer aided design (CAD) and computer aided analysis (CAA). The purpose of this investigation is to establish the relationship between the B-spline and NURBS, which are widely used in the geometric modeling, and the ANCF finite elements. It is shown in this study that by using the ANCF finite elements, one can in a straightforward manner obtain the control point representation required for the Bezier, B-spline and NURBS geometry. To this end, a coordinate transformation is used to write the ANCF gradient vectors in terms of control points. Unifying the CAD and CAA will require the use of such coordinate transformations and their inverses in order to transform control points to position vector gradients which are required for the formulation of the element transformations in the case of discontinuities as well as the formulation of the strain measures and the stress forces based on general continuum mechanics theory. In particular, fully parameterized ANCF finite elements can be very powerful in describing curve, surface, and volume geometry, and they can be effectively used to describe discontinuities while maintaining the many ANCF desirable features that include a constant mass matrix, zero Coriolis and centrifugal forces, no restriction on the amount of rotation or deformation within the finite element, ability for straightforward implementation of general

  9. Assess/Mitigate Risk through the Use of Computer-Aided Software Engineering (CASE) Tools

    Science.gov (United States)

    Aguilar, Michael L.

    2013-01-01

    The NASA Engineering and Safety Center (NESC) was requested to perform an independent assessment of the mitigation of the Constellation Program (CxP) Risk 4421 through the use of computer-aided software engineering (CASE) tools. With the cancellation of the CxP, the assessment goals were modified to capture lessons learned and best practices in the use of CASE tools. The assessment goal was to prepare the next program for the use of these CASE tools. The outcome of the assessment is contained in this document.

  10. Computer-aided tomographic diagnosis of lymphadenopathies in malignant nonhodgkin's lymphomas

    International Nuclear Information System (INIS)

    Cheremisin, V.M.; Mazurov, V.K.; Anosov, N.A.; Savello, V.E.; Belov, A.F.; Novikov, A.A.; Mel'nichenko, V.Ya.; Nikolaevich, M.S.

    1996-01-01

    The potentialities of computer-aided tomography (CAT) in the diagnosis of lymphomas were studied. A total of 223 patients with disseminated lymphadenopathy were examined (78 with malignant non-Hodgkin's lymphomas, 48 with Hodgkin'sn disease, 54 with metastatic involvement of the lymph nodes, 18 with HIV infection, and 25 with reactive and inflammatory lymphadenopathy). CAT helped precisely assess the dissemination of the pathological process and disease stage in patients with malignant lymphomas, permitted follow up the time course of the disease, and facilitated differentiation of the condition from other diseases manifesting by disseminated lymphadenopathies

  11. Generic Mathematical Programming Formulation and Solution for Computer-Aided Molecular Design

    DEFF Research Database (Denmark)

    Zhang, Lei; Cignitti, Stefano; Gani, Rafiqul

    2015-01-01

    This short communication presents a generic mathematical programming formulation for Computer-Aided Molecular Design (CAMD). A given CAMD problem, based on target properties, is formulated as a Mixed Integer Linear/Non-Linear Program (MILP/MINLP). The mathematical programming model presented here......, which is formulated as an MILP/MINLP problem, considers first-order and second-order molecular groups for molecular structure representation and property estimation. It is shown that various CAMD problems can be formulated and solved through this model....

  12. Computer aided process control equipment at the Karlsruhe reprocessing pilot plant, WAK

    International Nuclear Information System (INIS)

    Winter, R.; Finsterwalder, L.; Gutzeit, G.; Reif, J.; Stollenwerk, A.H.; Weinbrecht, E.; Weishaupt, M.

    1991-01-01

    A computer aided process control system has been installed at the Karlsruhe Spent Fuel Reprocessing Plant, WAK. All necessary process control data of the first extraction cycle is collected via a data collection system and is displayed in suitable ways on a screen for the operator in charge of the unit. To aid verification of displayed data, various measurements are associated to each other using balance type process modeling. Thus, deviation of flowsheet conditions and malfunctioning of measuring equipment are easily detected. (orig.) [de

  13. Hardware synthesis from DDL. [Digital Design Language for computer aided design and test of LSI

    Science.gov (United States)

    Shah, A. M.; Shiva, S. G.

    1981-01-01

    The details of the digital systems can be conveniently input into the design automation system by means of Hardware Description Languages (HDL). The Computer Aided Design and Test (CADAT) system at NASA MSFC is used for the LSI design. The Digital Design Language (DDL) has been selected as HDL for the CADAT System. DDL translator output can be used for the hardware implementation of the digital design. This paper addresses problems of selecting the standard cells from the CADAT standard cell library to realize the logic implied by the DDL description of the system.

  14. Automation of reliability evaluation procedures through CARE - The computer-aided reliability estimation program.

    Science.gov (United States)

    Mathur, F. P.

    1972-01-01

    Description of an on-line interactive computer program called CARE (Computer-Aided Reliability Estimation) which can model self-repair and fault-tolerant organizations and perform certain other functions. Essentially CARE consists of a repository of mathematical equations defining the various basic redundancy schemes. These equations, under program control, are then interrelated to generate the desired mathematical model to fit the architecture of the system under evaluation. The mathematical model is then supplied with ground instances of its variables and is then evaluated to generate values for the reliability-theoretic functions applied to the model.

  15. Study of the computer-aided implantation and layout of printed circuits

    International Nuclear Information System (INIS)

    Baudry, Marc

    1973-01-01

    This research thesis reports the design and implementation of a software aimed at a computer-aided implantation and layout of printed circuits. This work comprises the use of heuristic algorithms and the search for a minimum cost by reduction of computing time and of memory size. The software comprises four independent parts which respectively address data analysis and control, circuit implantation, connection layout, and the exploitation of the obtained results. These four parts and their subroutines are presented. Two examples are reported in appendix

  16. Computer-aided approach for design of tailor-made blended products

    DEFF Research Database (Denmark)

    Yunus, Nor Alafiza; Gernaey, Krist; Woodley, John

    2012-01-01

    A computer-aided methodology has been developed for the design of blended (mixture) products. Through this methodology, it is possible to identify the most suitable chemicals for blending, and “tailor” the blend according to specified product needs (usually product attributes, e.g. performance...... as well as regulatory). The product design methodology has four tasks. First, the design problem is defined: the product needs are identified, translated into target properties and the constraints for each target property are defined. Secondly, target property models are retrieved from a property model...

  17. Computer-aided design studies of the homopolar linear synchronous motor

    Science.gov (United States)

    Dawson, G. E.; Eastham, A. R.; Ong, R.

    1984-09-01

    The linear induction motor (LIM), as an urban transit drive, can provide good grade-climbing capabilities and propulsion/braking performance that is independent of steel wheel-rail adhesion. In view of its 10-12 mm airgap, the LIM is characterized by a low power factor-efficiency product of order 0.4. A synchronous machine offers high efficiency and controllable power factor. An assessment of the linear homopolar configuration of this machine is presented as an alternative to the LIM. Computer-aided design studies using the finite element technique have been conducted to identify a suitable machine design for urban transit propulsion.

  18. Computer-aided preparation of specifications for radial fans at VEB Lufttechnische Anlagen Berlin

    Energy Technology Data Exchange (ETDEWEB)

    Kubis, R.; Kull, W.

    1987-01-01

    The specification details the scope of delivery for radial fans on a standard page and also serves the preparation for production. In the place of previous manual preparation, a computer-aided technique for the office computer is presented that provides the technical parameters from data files out of few input data to identify the fan type. The data files and evaluative programs are based on the software tool REDABAS and the SCP operating system. Using this technique it has been possible to cut considerably the preparation time for the incoming orders.

  19. Computer-aided system for fire fighting in an underground mine

    Energy Technology Data Exchange (ETDEWEB)

    Rosiek, F; Sikora, M; Urbanski, J [Politechnika Wroclawska (Poland). Instytut Gornictwa

    1989-01-01

    Discusses structure of an algorithm for computer-aided planning of fire fighting and rescue in an underground coal mine. The algorithm developed by the Mining Institute of the Wroclaw Technical University consists of ten options: regulations on fire fighting, fire alarm for miners working underground (rescue ways, fire zones etc.), information system for mine management, movements of fire fighting teams, distribution of fire fighting equipment, assessment of explosion hazards of fire gases, fire gas temperature control of blower operation, detection of endogenous fires, ventilation control. 2 refs.

  20. Application of integrated computer-aided engineering for design, construction and operation of nuclear power plant

    International Nuclear Information System (INIS)

    Kyung-shick Min; Byung-hun Lee

    1987-01-01

    Computer-aided-engineering (CAE) is an essential tool for modern nuclear power plant engineering. It greatly varies in definition, application, and technology from project to project and company to company. Despite the fast growing technologies and applications of CAE, its complexty and variety have thrown aonther puzzle to management of a nuclear project. Without due consideration of an integrated CAE system in early planning stage, the overall efficiency of a nuclear project would slow down due to the inefficiency in data flow. In this paper, practices and perspectives of CAE appliation are discussed under the Korea Power Engineering Company (KOPEC) philosophy in CAE approach. (author)