  1. Proton computed tomography images with algebraic reconstruction

    Science.gov (United States)

    Bruzzi, M.; Civinini, C.; Scaringella, M.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Presti, D. Lo; Maccioni, G.; Pallotta, S.; Randazzo, N.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.

    2017-02-01

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to 1% and spatial resolutions CT in hadron-therapy.

  2. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... and limitations of sparse reconstruction methods in CT, in particular in a quantitative sense. For example, relations between image properties such as contrast, structure and sparsity, tolerable noise levels, suficient sampling levels, the choice of sparse reconstruction formulation and the achievable image...

  3. Reconstructing cetacean brain evolution using computed tomography.

    Science.gov (United States)

    Marino, Lori; Uhen, Mark D; Pyenson, Nicholas D; Frohlich, Bruno

    2003-05-01

    Until recently, there have been relatively few studies of brain mass and morphology in fossil cetaceans (dolphins, whales, and porpoises) because of difficulty accessing the matrix that fills the endocranial cavity of fossil cetacean skulls. As a result, our knowledge about cetacean brain evolution has been quite limited. By applying the noninvasive technique of computed tomography (CT) to visualize, measure, and reconstruct the endocranial morphology of fossil cetacean skulls, we can gain vastly more information at an unprecedented rate about cetacean brain evolution. Here, we discuss our method and demonstrate it with several examples from our fossil cetacean database. This approach will provide new insights into the little-known evolutionary history of cetacean brain evolution.

  4. Iterative Reconstruction for Cardiopulmonary Computed Tomography

    NARCIS (Netherlands)

    Willemink, M.J.

    2015-01-01

    Introduction The number of computed tomography (CT) examinations has increased rapidly since CT became commercially available. This resulted in growing concerns regarding the risk of malignancies induced by application of medical ionizing radiation. Therefore, radiation dose reduction strategies ar

  5. Evaluating iterative reconstruction performance in computed tomography.

    Science.gov (United States)

    Chen, Baiyu; Ramirez Giraldo, Juan Carlos; Solomon, Justin; Samei, Ehsan

    2014-12-01

    Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d'). d' was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1-4 mm), contrast levels (10-100 HU), and edge profiles (sharp and soft). Unique d' values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDIvol: 3.4-64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d' values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction potentials (11-54 mGy, 77%-84%), followed by

  6. Material reconstruction for spectral computed tomography with detector response function

    Science.gov (United States)

    Liu, Jiulong; Gao, Hao

    2016-11-01

    Different from conventional computed tomography (CT), spectral CT using energy-resolved photon-counting detectors is able to provide the unprecedented material compositions. However accurate spectral CT needs to account for the detector response function (DRF), which is often distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. The simulation results suggest that the proposed methods reconstructed more accurate material compositions than the conventional method without DRF. Moreover, the proposed linearized method with linear data fidelity from spectral resampling had improved reconstruction quality from the nonlinear method directly based on nonlinear data fidelity.

  7. Denoising Message Passing for X-ray Computed Tomography Reconstruction

    CERN Document Server

    Perelli, Alessandro; Can, Ali; Davies, Mike E

    2016-01-01

    X-ray Computed Tomography (CT) reconstruction from sparse number of views is becoming a powerful way to reduce either the radiation dose or the acquisition time in CT systems but still requires a huge computational time. This paper introduces an approximate Bayesian inference framework for CT reconstruction based on a family of denoising approximate message passing (DCT-AMP) algorithms able to improve both the convergence speed and the reconstruction quality. Approximate Message Passing for Compressed Sensing has been extensively analysed for random linear measurements but there are still not clear solutions on how AMP should be modified and how it performs with real world problems. In particular to overcome the convergence issues of DCT-AMP with structured measurement matrices, we propose a disjoint preconditioned version of the algorithm tailored for both the geometric system model and the noise model. In addition the Bayesian DCT-AMP formulation allows to measure how the current estimate is close to the pr...

  8. Visualization of simulated small vessels on computed tomography using a model-based iterative reconstruction technique

    Directory of Open Access Journals (Sweden)

    Toru Higaki

    2017-08-01

    Full Text Available This article describes a quantitative evaluation of visualizing small vessels using several image reconstruction methods in computed tomography. Simulated vessels with diameters of 1–6 mm made by 3D printer was scanned using 320-row detector computed tomography (CT. Hybrid iterative reconstruction (hybrid IR and model-based iterative reconstruction (MBIR were performed for the image reconstruction.

  9. Proton Computed Tomography: iterative image reconstruction and dose evaluation

    Science.gov (United States)

    Civinini, C.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Lo Presti, D.; Maccioni, G.; Pallotta, S.; Randazzo, N.; Scaringella, M.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.; Bruzzi, M.

    2017-01-01

    Proton Computed Tomography (pCT) is a medical imaging method with a potential for increasing accuracy of treatment planning and patient positioning in hadron therapy. A pCT system based on a Silicon microstrip tracker and a YAG:Ce crystal calorimeter has been developed within the INFN Prima-RDH collaboration. The prototype has been tested with a 175 MeV proton beam at The Svedberg Laboratory (Uppsala, Sweden) with the aim to reconstruct and characterize a tomographic image. Algebraic iterative reconstruction methods (ART), together with the most likely path formalism, have been used to obtain tomographies of an inhomogeneous phantom to eventually extract density and spatial resolutions. These results will be presented and discussed together with an estimation of the average dose delivered to the phantom and the dependence of the image quality on the dose. Due to the heavy computation load required by the algebraic algorithms the reconstruction programs have been implemented to fully exploit the high calculation parallelism of Graphics Processing Units. An extended field of view pCT system is in an advanced construction stage. This apparatus will be able to reconstruct objects of the size of a human head making possible to characterize this pCT approach in a pre-clinical environment.

  10. Iterative image reconstruction and its role in cardiothoracic computed tomography.

    Science.gov (United States)

    Singh, Sarabjeet; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Padole, Atul; Lira, Diego; Kalra, Mannudeep K

    2013-11-01

    Revolutionary developments in multidetector-row computed tomography (CT) scanner technology offer several advantages for imaging of cardiothoracic disorders. As a result, expanding applications of CT now account for >85 million CT examinations annually in the United States alone. Given the large number of CT examinations performed, concerns over increase in population-based risk for radiation-induced carcinogenesis have made CT radiation dose a top safety concern in health care. In response to this concern, several technologies have been developed to reduce the dose with more efficient use of scan parameters and the use of "newer" image reconstruction techniques. Although iterative image reconstruction algorithms were first introduced in the 1970s, filtered back projection was chosen as the conventional image reconstruction technique because of its simplicity and faster reconstruction times. With subsequent advances in computational speed and power, iterative reconstruction techniques have reemerged and have shown the potential of radiation dose optimization without adversely influencing diagnostic image quality. In this article, we review the basic principles of different iterative reconstruction algorithms and their implementation for various clinical applications in cardiothoracic CT examinations for reducing radiation dose.

  11. Compensation for air voids in photoacoustic computed tomography image reconstruction

    Science.gov (United States)

    Matthews, Thomas P.; Li, Lei; Wang, Lihong V.; Anastasio, Mark A.

    2016-03-01

    Most image reconstruction methods in photoacoustic computed tomography (PACT) assume that the acoustic properties of the object and the surrounding medium are homogeneous. This can lead to strong artifacts in the reconstructed images when there are significant variations in sound speed or density. Air voids represent a particular challenge due to the severity of the differences between the acoustic properties of air and water. In whole-body small animal imaging, the presence of air voids in the lungs, stomach, and gastrointestinal system can limit image quality over large regions of the object. Iterative reconstruction methods based on the photoacoustic wave equation can account for these acoustic variations, leading to improved resolution, improved contrast, and a reduction in the number of imaging artifacts. However, the strong acoustic heterogeneities can lead to instability or errors in the numerical wave solver. Here, the impact of air voids on PACT image reconstruction is investigated, and procedures for their compensation are proposed. The contributions of sound speed and density variations to the numerical stability of the wave solver are considered, and a novel approach for mitigating the impact of air voids while reducing the computational burden of image reconstruction is identified. These results are verified by application to an experimental phantom.

  12. Direct reconstruction of enhanced signal in computed tomography perfusion

    Science.gov (United States)

    Li, Bin; Lyu, Qingwen; Ma, Jianhua; Wang, Jing

    2016-04-01

    High imaging dose has been a concern in computed tomography perfusion (CTP) as repeated scans are performed at the same location of a patient. On the other hand, signal changes only occur at limited regions in CT acquired at different time points. In this work, we propose a new reconstruction strategy by effectively utilizing the initial phase high-quality CT to reconstruct the later phase CT acquired with a low-dose protocol. In the proposed strategy, initial high-quality CT is considered as a base image and enhanced signal (ES) is reconstructed directly by minimizing the penalized weighted least-square (PWLS) criterion. The proposed PWLS-ES strategy converts the conventional CT reconstruction into a sparse signal reconstruction problem. Digital and anthropomorphic phantom studies were performed to evaluate the performance of the proposed PWLS-ES strategy. Both phantom studies show that the proposed PWLS-ES method outperforms the standard iterative CT reconstruction algorithm based on the same PWLS criterion according to various quantitative metrics including root mean squared error (RMSE) and the universal quality index (UQI).

  13. Improved proton computed tomography by dual modality image reconstruction

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Bassler, Niels; Petersen, Jørgen B.B.;

    2014-01-01

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full...... nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully...

  14. Computed tomography image reconstruction from only two projections

    CERN Document Server

    Mohammad-Djafari, Ali

    2007-01-01

    English: This paper concerns the image reconstruction from a few projections in Computed Tomography (CT). The main objective of this paper is to show that the problem is so ill posed that no classical method, such as analytical methods based on inverse Radon transform, nor the algebraic methods such as Least squares (LS) or regularization theory can give satisfactory result. As an example, we consider in detail the case of image reconstruction from two horizontal and vertical projections. We then show how a particular composite Markov modeling and the Bayesian estimation framework can possibly propose satisfactory solutions to the problem. For demonstration and educational purpose a set of Matlab programs are given for a live presentation of the results. ----- French: Ce travail, \\`a but p\\'edagogique, pr\\'esente le probl\\`eme inverse de la reconstruction d'image en tomographie X lorsque le nombre des projections est tr\\`es limit\\'e. voir le texte en Anglais et en Fran\\c{c}ais.

  15. Continuous analog of multiplicative algebraic reconstruction technique for computed tomography

    Science.gov (United States)

    Tateishi, Kiyoko; Yamaguchi, Yusaku; Abou Al-Ola, Omar M.; Kojima, Takeshi; Yoshinaga, Tetsuya

    2016-03-01

    We propose a hybrid dynamical system as a continuous analog to the block-iterative multiplicative algebraic reconstruction technique (BI-MART), which is a well-known iterative image reconstruction algorithm for computed tomography. The hybrid system is described by a switched nonlinear system with a piecewise smooth vector field or differential equation and, for consistent inverse problems, the convergence of non-negatively constrained solutions to a globally stable equilibrium is guaranteed by the Lyapunov theorem. Namely, we can prove theoretically that a weighted Kullback-Leibler divergence measure can be a common Lyapunov function for the switched system. We show that discretizing the differential equation by using the first-order approximation (Euler's method) based on the geometric multiplicative calculus leads to the same iterative formula of the BI-MART with the scaling parameter as a time-step of numerical discretization. The present paper is the first to reveal that a kind of iterative image reconstruction algorithm is constructed by the discretization of a continuous-time dynamical system for solving tomographic inverse problems. Iterative algorithms with not only the Euler method but also the Runge-Kutta methods of lower-orders applied for discretizing the continuous-time system can be used for image reconstruction. A numerical example showing the characteristics of the discretized iterative methods is presented.

  16. Oblique reconstruction of the cruciate ligaments on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Hidetoshi; Nishino, Koshi; Koga, Masayuki; Kitakata, Akira; Deya, Keizo; Nakagawa, Hiroto

    1984-12-01

    Optimal positioning where the entire longitudinal axis of the cruciate ligaments could be demonstrated on computed tomography was discovered by using an amputated knee and was applied clinically. To demonstrate the anterior cruciate ligament, the patient was positioned on the table with the hip flexed, abducted, externally rotated and knee flexed at a 110-140 degrees angle. For the posterior cruciate ligament, the patient was placed in a prone position on the table with the knee flexed at a 50 degrees angle. These positions, especially the one for the anterior cruciate ligament, were difficult for some patients with gonalgia or limited range of motion. Reconstruction in the oblique planes was studied for those patients by using an amputated knee and quasi-ligament made of gum. Clinically, an axial image was obtained by the simple position of the patient lying prone on the table with knee extended. Oblique reconstruction was made from the axial images and this reconstructed image also demonstrated the entire longitudinal axis of the ligament. The rupture of the cruciate ligaments could be assessed by the reconstructed image in the oblique plane. (author).

  17. Model-based image reconstruction in X-ray computed tomography

    NARCIS (Netherlands)

    Zbijewski, Wojciech Bartosz

    2006-01-01

    The thesis investigates the applications of iterative, statistical reconstruction (SR) algorithms in X-ray Computed Tomography. Emphasis is put on various aspects of system modeling in statistical reconstruction. Fundamental issues such as effects of object discretization and algorithm initializatio

  18. Improved proton computed tomography by dual modality image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, David C., E-mail: dch@ki.au.dk; Bassler, Niels [Experimental Clinical Oncology, Aarhus University, 8000 Aarhus C (Denmark); Petersen, Jørgen Breede Baltzer [Medical Physics, Aarhus University Hospital, 8000 Aarhus C (Denmark); Sørensen, Thomas Sangild [Computer Science, Aarhus University, 8000 Aarhus C, Denmark and Clinical Medicine, Aarhus University, 8200 Aarhus N (Denmark)

    2014-03-15

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360

  19. Prior image constrained image reconstruction in emerging computed tomography applications

    Science.gov (United States)

    Brunner, Stephen T.

    Advances have been made in computed tomography (CT), especially in the past five years, by incorporating prior images into the image reconstruction process. In this dissertation, we investigate prior image constrained image reconstruction in three emerging CT applications: dual-energy CT, multi-energy photon-counting CT, and cone-beam CT in image-guided radiation therapy. First, we investigate the application of Prior Image Constrained Compressed Sensing (PICCS) in dual-energy CT, which has been called "one of the hottest research areas in CT." Phantom and animal studies are conducted using a state-of-the-art 64-slice GE Discovery 750 HD CT scanner to investigate the extent to which PICCS can enable radiation dose reduction in material density and virtual monochromatic imaging. Second, we extend the application of PICCS from dual-energy CT to multi-energy photon-counting CT, which has been called "one of the 12 topics in CT to be critical in the next decade." Numerical simulations are conducted to generate multiple energy bin images for a photon-counting CT acquisition and to investigate the extent to which PICCS can enable radiation dose efficiency improvement. Third, we investigate the performance of a newly proposed prior image constrained scatter correction technique to correct scatter-induced shading artifacts in cone-beam CT, which, when used in image-guided radiation therapy procedures, can assist in patient localization, and potentially, dose verification and adaptive radiation therapy. Phantom studies are conducted using a Varian 2100 EX system with an on-board imager to investigate the extent to which the prior image constrained scatter correction technique can mitigate scatter-induced shading artifacts in cone-beam CT. Results show that these prior image constrained image reconstruction techniques can reduce radiation dose in dual-energy CT by 50% in phantom and animal studies in material density and virtual monochromatic imaging, can lead to radiation

  20. Just Scan It!-Weapon Reconstruction in Computed Tomography on Historical and Current Swiss Military Guns.

    Science.gov (United States)

    Franckenberg, Sabine; Binder, Thomas; Bolliger, Stephan; Thali, Michael J; Ross, Steffen G

    2016-09-01

    Cross-sectional imaging, such as computed tomography, has been increasingly implemented in both historic and recent postmortem forensic investigations. It aids in determining cause and manner of death as well as in correlating injuries to possible weapons. This study illuminates the feasibility of reconstructing guns in computed tomography and gives a distinct overview of historic and recent Swiss Army guns.

  1. Reconstruction Algorithms for Positron Emission Tomography and Single Photon Emission Computed Tomography and their Numerical Implementation

    CERN Document Server

    Fokas, A S; Marinakis, V

    2004-01-01

    The modern imaging techniques of Positron Emission Tomography and of Single Photon Emission Computed Tomography are not only two of the most important tools for studying the functional characteristics of the brain, but they now also play a vital role in several areas of clinical medicine, including neurology, oncology and cardiology. The basic mathematical problems associated with these techniques are the construction of the inverse of the Radon transform and of the inverse of the so called attenuated Radon transform respectively. We first show that, by employing mathematical techniques developed in the theory of nonlinear integrable equations, it is possible to obtain analytic formulas for these two inverse transforms. We then present algorithms for the numerical implementation of these analytic formulas, based on approximating the given data in terms of cubic splines. Several numerical tests are presented which suggest that our algorithms are capable of producing accurate reconstruction for realistic phanto...

  2. 2.5D dictionary learning based computed tomography reconstruction

    Science.gov (United States)

    Luo, Jiajia; Eri, Haneda; Can, Ali; Ramani, Sathish; Fu, Lin; De Man, Bruno

    2016-05-01

    A computationally efficient 2.5D dictionary learning (DL) algorithm is proposed and implemented in the model- based iterative reconstruction (MBIR) framework for low-dose CT reconstruction. MBIR is based on the minimization of a cost function containing data-fitting and regularization terms to control the trade-off between data-fidelity and image noise. Due to the strong denoising performance of DL, it has previously been considered as a regularizer in MBIR, and both 2D and 3D DL implementations are possible. Compared to the 2D case, 3D DL keeps more spatial information and generates images with better quality although it requires more computation. We propose a novel 2.5D DL scheme, which leverages the computational advantage of 2D-DL, while attempting to maintain reconstruction quality similar to 3D-DL. We demonstrate the effectiveness of this new 2.5D DL scheme for MBIR in low-dose CT. By applying the 2D DL method in three different orthogonal planes and calculating the sparse coefficients accordingly, much of the 3D spatial information can be preserved without incurring the computational penalty of the 3D DL method. For performance evaluation, we use baggage phantoms with different number of projection views. In order to quantitatively compare the performance of different algorithms, we use PSNR, SSIM and region based standard deviation to measure the noise level, and use the edge response to calculate the resolution. Experimental results with full view datasets show that the different DL based algorithms have similar performance and 2.5D DL has the best resolution. Results with sparse view datasets show that 2.5D DL outperforms both 2D and 3D DL in terms of noise reduction. We also compare the computational costs, and 2.5D DL shows strong advantage over 3D DL in both full-view and sparse-view cases.

  3. High-performance computing and networking as tools for accurate emission computed tomography reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Passeri, A. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); Formiconi, A.R. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); De Cristofaro, M.T.E.R. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); Pupi, A. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); Meldolesi, U. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy)

    1997-04-01

    It is well known that the quantitative potential of emission computed tomography (ECT) relies on the ability to compensate for resolution, attenuation and scatter effects. Reconstruction algorithms which are able to take these effects into account are highly demanding in terms of computing resources. The reported work aimed to investigate the use of a parallel high-performance computing platform for ECT reconstruction taking into account an accurate model of the acquisition of single-photon emission tomographic (SPET) data. An iterative algorithm with an accurate model of the variable system response was ported on the MIMD (Multiple Instruction Multiple Data) parallel architecture of a 64-node Cray T3D massively parallel computer. The system was organized to make it easily accessible even from low-cost PC-based workstations through standard TCP/IP networking. A complete brain study of 30 (64 x 64) slices could be reconstructed from a set of 90 (64 x 64) projections with ten iterations of the conjugate gradients algorithm in 9 s, corresponding to an actual speed-up factor of 135. This work demonstrated the possibility of exploiting remote high-performance computing and networking resources from hospital sites by means of low-cost workstations using standard communication protocols without particular problems for routine use. The achievable speed-up factors allow the assessment of the clinical benefit of advanced reconstruction techniques which require a heavy computational burden for the compensation effects such as variable spatial resolution, scatter and attenuation. The possibility of using the same software on the same hardware platform with data acquired in different laboratories with various kinds of SPET instrumentation is appealing for software quality control and for the evaluation of the clinical impact of the reconstruction methods. (orig.). With 4 figs., 1 tab.

  4. BPF-type Region-of-interest Reconstruction for Parallel Translational Computed Tomography

    CERN Document Server

    Wu, Weiwen; Wang, Shaoyu; Liu, Fenglin

    2016-01-01

    Recently, an ultra-low-cost linear scan based tomography architecture was proposed by our team. Similar to linear tomosynthesis, the source and detector are translated in opposite directions and the data acquisition system targets on a region-of-interest (ROI) to acquire data for image reconstruction. This kind of tomography architecture was named parallel translational computed tomography (PTCT). In our previous studies, filtered backprojection (FBP)-type algorithms were developed to reconstruct images from PTCT. However, the reconstructed ROI images from truncated projections have severe truncation artifacts. In this paper, we propose two backprojection filtering (BPF)-type algorithms named MP-BPF and MZ-BPF to reconstruct ROI images from truncated PTCT data. A weight function is constructed to deal with data redundancy for multi-linear translations modes. Extensive numerical simulations are performed to evaluate the proposed MP-BPF and MZ-BPF algorithms for PTCT in fan-beam geometry. Qualitative and quanti...

  5. Computed Tomography Radiation Dose Reduction: Effect of Different Iterative Reconstruction Algorithms on Image Quality

    NARCIS (Netherlands)

    Willemink, M.J.; Takx, R.A.P.; Jong, P.A. de; Budde, R.P.; Bleys, R.L.; Das, M.; Wildberger, J.E.; Prokop, M.; Buls, N.; Mey, J. de; Leiner, T.; Schilham, A.M.

    2014-01-01

    We evaluated the effects of hybrid and model-based iterative reconstruction (IR) algorithms from different vendors at multiple radiation dose levels on image quality of chest phantom scans.A chest phantom was scanned on state-of-the-art computed tomography scanners from 4 vendors at 4 dose levels

  6. The Impact of Iterative Reconstruction on Computed Tomography Radiation Dosimetry: Evaluation in a Routine Clinical Setting.

    Directory of Open Access Journals (Sweden)

    Rachael E Moorin

    Full Text Available To evaluate the effect of introduction of iterative reconstruction as a mandated software upgrade on radiation dosimetry in routine clinical practice over a range of computed tomography examinations.Random samples of scanning data were extracted from a centralised Picture Archiving Communication System pertaining to 10 commonly performed computed tomography examination types undertaken at two hospitals in Western Australia, before and after the introduction of iterative reconstruction. Changes in the mean dose length product and effective dose were evaluated along with estimations of associated changes to annual cancer incidence.We observed statistically significant reductions in the effective radiation dose for head computed tomography (22-27% consistent with those reported in the literature. In contrast the reductions observed for non-contrast chest (37-47%; chest pulmonary embolism study (28%, chest/abdominal/pelvic study (16% and thoracic spine (39% computed tomography. Statistically significant reductions in radiation dose were not identified in angiographic computed tomography. Dose reductions translated to substantial lowering of the lifetime attributable risk, especially for younger females, and estimated numbers of incident cancers.Reduction of CT dose is a priority Iterative reconstruction algorithms have the potential to significantly assist with dose reduction across a range of protocols. However, this reduction in dose is achieved via reductions in image noise. Fully realising the potential dose reduction of iterative reconstruction requires the adjustment of image factors and forgoing the noise reduction potential of the iterative algorithm. Our study has demonstrated a reduction in radiation dose for some scanning protocols, but not to the extent experimental studies had previously shown or in all protocols expected, raising questions about the extent to which iterative reconstruction achieves dose reduction in real world clinical

  7. Iterative Reconstruction of Computed Axial Tomography images based on GPUs; Reconstruccion Iterativa de Imagenes TAC basada en GPUs

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, V.; Florez, L. A.; Mayo, P.; Rodenas, F.; Verdu, G.

    2013-07-01

    Although widely used in nuclear medicine (gamma-cameras, SPECT-single photon emission computed tomography, positron emission tomography, PET), the iterative image reconstruction is not widespread in Computed tomography (CT). The biggest reason for this is that the data set required in TAC is much higher than in nuclear medicine and iterative reconstruction is computationally very intensive. The graphics processing units (GPUs) provide the possibility to reduce the high computational cost of rebuilding in an effective way. The objective of this work is to develop image reconstruction algorithm based on GPUs.

  8. A constrained variable projection reconstruction method for photoacoustic computed tomography without accurate knowledge of transducer responses

    CERN Document Server

    Sheng, Qiwei; Matthews, Thomas P; Xia, Jun; Zhu, Liren; Wang, Lihong V; Anastasio, Mark A

    2015-01-01

    Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging system employs conventional piezoelectric ultrasonic transducers, the ideal photoacoustic (PA) signals are degraded by the transducers' acousto-electric impulse responses (EIRs) during the measurement process. If unaccounted for, this can degrade the accuracy of the reconstructed image. In principle, the effect of the EIRs on the measured PA signals can be ameliorated via deconvolution; images can be reconstructed subsequently by application of a reconstruction method that assumes an idealized EIR. Alternatively, the effect of the EIR can be incorporated into an imaging model and implicitly compensated for during reconstruction. In either case, the efficacy of the correction can be limited by errors in the assumed EIRs. In this work, a joint optimization approach to PACT image r...

  9. Influence of Adaptive Statistical Iterative Reconstruction on coronary plaque analysis in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H; Broersen, Alexander

    2016-01-01

    PURPOSE: The purpose of this study was to study the effect of iterative reconstruction (IR) software on quantitative plaque measurements in coronary computed tomography angiography (CCTA). METHODS: Thirty patients with a three clinical risk factors for coronary artery disease (CAD) had one CCTA...... performed. Images were reconstructed using FBP, 30% and 60% adaptive statistical IR (ASIR). Coronary plaque analysis was performed as per patient and per vessel (LM, LAD, CX and RCA) measurements. Lumen and vessel volumes and plaque burden measurements were based on automatic detected contours in each...

  10. Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle–Pock algorithm

    DEFF Research Database (Denmark)

    Sidky, Emil Y.; Jørgensen, Jakob Heide; Pan, Xiaochuan

    2012-01-01

    for the purpose of designing iterative image reconstruction algorithms for CT. The primal–dual algorithm is briefly summarized in this paper, and its potential for prototyping is demonstrated by explicitly deriving CP algorithm instances for many optimization problems relevant to CT. An example application......The primal–dual optimization algorithm developed in Chambolle and Pock (CP) (2011 J. Math. Imag. Vis. 40 1–26) is applied to various convex optimization problems of interest in computed tomography (CT) image reconstruction. This algorithm allows for rapid prototyping of optimization problems...

  11. Evaluation of algebraic iterative image reconstruction methods for tetrahedron beam computed tomography systems.

    Science.gov (United States)

    Kim, Joshua; Guan, Huaiqun; Gersten, David; Zhang, Tiezhi

    2013-01-01

    Tetrahedron beam computed tomography (TBCT) performs volumetric imaging using a stack of fan beams generated by a multiple pixel X-ray source. While the TBCT system was designed to overcome the scatter and detector issues faced by cone beam computed tomography (CBCT), it still suffers the same large cone angle artifacts as CBCT due to the use of approximate reconstruction algorithms. It has been shown that iterative reconstruction algorithms are better able to model irregular system geometries and that algebraic iterative algorithms in particular have been able to reduce cone artifacts appearing at large cone angles. In this paper, the SART algorithm is modified for the use with the different TBCT geometries and is tested using both simulated projection data and data acquired using the TBCT benchtop system. The modified SART reconstruction algorithms were able to mitigate the effects of using data generated at large cone angles and were also able to reconstruct CT images without the introduction of artifacts due to either the longitudinal or transverse truncation in the data sets. Algebraic iterative reconstruction can be especially useful for dual-source dual-detector TBCT, wherein the cone angle is the largest in the center of the field of view.

  12. Evaluation of Algebraic Iterative Image Reconstruction Methods for Tetrahedron Beam Computed Tomography Systems

    Directory of Open Access Journals (Sweden)

    Joshua Kim

    2013-01-01

    Full Text Available Tetrahedron beam computed tomography (TBCT performs volumetric imaging using a stack of fan beams generated by a multiple pixel X-ray source. While the TBCT system was designed to overcome the scatter and detector issues faced by cone beam computed tomography (CBCT, it still suffers the same large cone angle artifacts as CBCT due to the use of approximate reconstruction algorithms. It has been shown that iterative reconstruction algorithms are better able to model irregular system geometries and that algebraic iterative algorithms in particular have been able to reduce cone artifacts appearing at large cone angles. In this paper, the SART algorithm is modified for the use with the different TBCT geometries and is tested using both simulated projection data and data acquired using the TBCT benchtop system. The modified SART reconstruction algorithms were able to mitigate the effects of using data generated at large cone angles and were also able to reconstruct CT images without the introduction of artifacts due to either the longitudinal or transverse truncation in the data sets. Algebraic iterative reconstruction can be especially useful for dual-source dual-detector TBCT, wherein the cone angle is the largest in the center of the field of view.

  13. Alternating Direction Total Variation Image Reconstruction and Practical Decomposition for Dual-energy Computed Tomography

    CERN Document Server

    Li, Lei; Wang, Linyuan; Yan, Bin; Zhang, Hanming; Zheng, Zhizhong; Zhang, Wenkun; Lu, Wanli; Hu, Guoen

    2016-01-01

    Dual-energy computed tomography (DECT) has shown great potential and promising applications in advanced imaging fields for its capabilities of material decomposition. However, image reconstructions and decompositions under sparse views dataset suffers severely from multi factors, such as insufficiencies of data, appearances of noise, and inconsistencies of observations. Under sparse views, conventional filtered back-projection type reconstruction methods fails to provide CT images with satisfying quality. Moreover, direct image decomposition is unstable and meet with noise boost even with full views dataset. This paper proposes an iterative image reconstruction algorithm and a practical image domain decomposition method for DECT. On one hand, the reconstruction algorithm is formulated as an optimization problem, which containing total variation regularization term and data fidelity term. The alternating direction method is utilized to design the corresponding algorithm which shows faster convergence speed com...

  14. PROCEEDINGS ON SYNCHROTRON RADIATION: An ART iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging

    Science.gov (United States)

    Wang, Zhen-Tian; Zhang, Li; Huang, Zhi-Feng; Kang, Ke-Jun; Chen, Zhi-Qiang; Fang, Qiao-Guang; Zhu, Pei-Ping

    2009-11-01

    X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low-Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging (DEI-CT). An Ordered Subsets (OS) technique is used to accelerate the ART reconstruction. Few-view reconstruction is also studied, and a partial differential equation (PDE) type filter which has the ability of edge-preserving and denoising is used to improve the image quality and eliminate the artifacts. The proposed algorithm is validated with both the numerical simulations and the experiment at the Beijing synchrotron radiation facility (BSRF).

  15. Waveform Inversion with Source Encoding for Breast Sound Speed Reconstruction in Ultrasound Computed Tomography

    CERN Document Server

    Wang, Kun; Anis, Fatima; Li, Cuiping; Duric, Neb; Anastasio, Mark A

    2015-01-01

    Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the sound speed distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Both computer-simulation and experimental phantom studies are conduc...

  16. Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Gonca; Courtier, Jesse L.; Phelps, Andrew; Marcovici, Peter A.; MacKenzie, John D. [UCSF Benioff Children' s Hospital, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2014-07-15

    Computed tomography (CT) is extremely important in characterizing blood vessel anatomy and vascular lesions in children. Recent advances in CT reconstruction technology hold promise for improved image quality and also reductions in radiation dose. This report evaluates potential improvements in image quality for the depiction of small pediatric vessels with model-based iterative reconstruction (Veo trademark), a technique developed to improve image quality and reduce noise. To evaluate Veo trademark as an improved method when compared to adaptive statistical iterative reconstruction (ASIR trademark) for the depiction of small vessels on pediatric CT. Seventeen patients (mean age: 3.4 years, range: 2 days to 10.0 years; 6 girls, 11 boys) underwent contrast-enhanced CT examinations of the chest and abdomen in this HIPAA compliant and institutional review board approved study. Raw data were reconstructed into separate image datasets using Veo trademark and ASIR trademark algorithms (GE Medical Systems, Milwaukee, WI). Four blinded radiologists subjectively evaluated image quality. The pulmonary, hepatic, splenic and renal arteries were evaluated for the length and number of branches depicted. Datasets were compared with parametric and non-parametric statistical tests. Readers stated a preference for Veo trademark over ASIR trademark images when subjectively evaluating image quality criteria for vessel definition, image noise and resolution of small anatomical structures. The mean image noise in the aorta and fat was significantly less for Veo trademark vs. ASIR trademark reconstructed images. Quantitative measurements of mean vessel lengths and number of branches vessels delineated were significantly different for Veo trademark and ASIR trademark images. Veo trademark consistently showed more of the vessel anatomy: longer vessel length and more branching vessels. When compared to the more established adaptive statistical iterative reconstruction algorithm, model

  17. Distortion of three-dimensional computed tomography. Effect of the reconstruction function

    Energy Technology Data Exchange (ETDEWEB)

    Tachibana, Masayuki; Senjyu, Tatsunori; Baba, Hitoshi [Kyushu Univ., Fukuoka (Japan). Hospital

    2001-09-01

    Three-dimensional computed tomography is distorted in the Z-direction because of the partial volume effect. This distortion depends on slice width, helical scanning pitch, interpolation, reconstruction function, and reconstruction interval. We studied the effect of the reconstruction function on distortion by scanning high- and low-contrast phantoms in which an acrylic ball was set on expandable polystyrene in Japanese isinglass. We found that, if the acrylic ball was larger than the slice width, a three-dimensional image could be reconstructed without distortion by setting the threshold between the acrylic ball's CT numbers and the CT numbers of the acrylic ball's surroundings (air or Japanese isinglass). The image was not dependent on the reconstruction function. However, the three-dimensional size of the acrylic ball was smaller than the ball's actual size. Further, with the reconstruction function in which the edge was emphasized, distortion and the change caused by the threshold were larger than with the normal reconstruction function. This was because the style of the profile curve on the axial-transverse direction (X-Y direction) was affected by emphasizing the edge. (author)

  18. Cone beam x-ray luminescence computed tomography reconstruction with a priori anatomical information

    Science.gov (United States)

    Lo, Pei-An; Lin, Meng-Lung; Jin, Shih-Chun; Chen, Jyh-Cheng; Lin, Syue-Liang; Chang, C. Allen; Chiang, Huihua Kenny

    2014-09-01

    X-ray luminescence computed tomography (XLCT) is a novel molecular imaging modality that reconstructs the optical distribution of x-ray-excited phosphor particles with prior informational of anatomical CT image. The prior information improves the accuracy of image reconstruction. The system can also present anatomical CT image. The optical system based on a high sensitive charge coupled device (CCD) is perpendicular with a CT system. In the XLCT system, the xray was adopted to excite the phosphor of the sample and CCD camera was utilized to acquire luminescence emitted from the sample in 360 degrees projection free-space. In this study, the fluorescence diffuse optical tomography (FDOT)-like algorithm was used for image reconstruction, the structural prior information was incorporated in the reconstruction by adding a penalty term to the minimization function. The phosphor used in this study is Gd2O2S:Tb. For the simulation and experiments, the data was collected from 16 projections. The cylinder phantom was 40 mm in diameter and contains 8 mm diameter inclusion; the phosphor in the in vivo study was 5 mm in diameter at a depth of 3 mm. Both the errors were no more than 5%. Based on the results from these simulation and experimental studies, the novel XLCT method has demonstrated the feasibility for in vivo animal model studies.

  19. Fast image filters as an alternative to reconstruction kernels in computed tomography

    Science.gov (United States)

    Flohr, Thomas; Schaller, Stefan; Stadler, Alexander; Brandhuber, Wolfgang; Niethammer, Matthias U.; Klingenbeck-Regn, Klaus W.; Steffen, Peter

    2001-07-01

    In Computed Tomography, axial resolution is determined by the slice collimation and the spiral algorithm, while in-plane resolution is determined by the reconstruction kernel. Both choices select a tradeoff between image resolution (sharpness) and pixel noise. We investigated an alternative approach using default settings for image reconstruction which provide narrow reconstructed slice-width and high in-plane resolution. If smoother images are desired, we filter the original (sharp) images, instead of performing a new reconstruction with a smoother kernel. A suitable filter function in the frequency domain is the ratio of smooth and original (sharp) kernel. Efficient implementation was achieved by a Fourier transform of this ratio to the spatial domain. Separating the 2D spatial filtering into two subsequent 1D filtering stages in x- and y-direction further reduces computational complexity. Using this approach, arbitrarily oriented multi-planar reformats (MPRs) can be treated in exactly the same way as axial images. Due to efficient implementation, interactive modification of the filter settings becomes possible, which completely replace the variety of different reconstruction kernels. We implemented a further promising application of the method to thorax imaging, where different regions of the thorax (lungs and mediastinum) are jointly presented in the same images using different filter settings and different windowing.

  20. Monte Carlo simulation in proton computed tomography: a study of image reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Inocente, Guilherme Franco; Stenico, Gabriela V.; Hormaza, Joel Mesa [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Inst. de Biociencias. Dept. de Fisica e Biofisica

    2012-07-01

    Full text: The radiation method is one of the most used for cancer treatment. In this context arises therapy with proton beams in front of conventional radiotherapy. It is known that with proton therapy there are more advantages to the patient treated when compared with more conventional methods. The dose distributed along the path, especially in healthy tissues - neighbor the tumor, is smaller and the accuracy of treatment is much better. To carry out the treatment, the patient undergoes a plan through images for visualization and location of the target volume. The main method for obtaining these images is computed tomography X-ray (XCT). For treatment with proton beam this imaging technique can to generate some uncertainties. The purpose of this project is to study the feasibility of reconstructing images generated from the irradiation with proton beams, thereby reducing some inaccuracies, as it will be the same type of radiation as treatment planning, and also to drastically reduce some errors location, since the planning can be done at the same place and just before where the patient is treated. This study aims to obtain a relationship between the intrinsic property of the interaction of photons and protons with matter. For this we use computational simulation based on Monte Carlo method with the code SRIM 2008 and MCNPX v.2.5.0, to reconstruct images using the technique used in conventional computed tomography. (author)

  1. Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

    Science.gov (United States)

    Bittencourt, Márcio Sommer; Schmidt, Bernhard; Seltmann, Martin; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner Günther; Achenbach, Stephan

    2011-10-01

    Improvements in image quality in cardiac computed tomography may be achieved through iterative image reconstruction techniques. We evaluated the ability of "Iterative Reconstruction in Image Space" (IRIS) reconstruction to reduce image noise and improve subjective image quality. 55 consecutive patients undergoing coronary CT angiography to rule out coronary artery stenosis were included. A dual source CT system and standard protocols were used. Images were reconstructed using standard filtered back projection and IRIS. Image noise, attenuation within the coronary arteries, contrast, signal to noise and contrast to noise parameters as well as subjective classification of image quality (using a scale with four categories) were evaluated and compared between the two image reconstruction protocols. Subjective image quality (2.8 ± 0.4 in filtered back projection and 2.8 ± 0.4 in iterative reconstruction) and the number of "evaluable" segments per patient 14.0 ± 1.2 in filtered back projection and 14.1 ± 1.1 in iterative reconstruction) were not significant different between the two methods. However iterative reconstruction had a lower image noise (22.6 ± 4.5 HU vs. 28.6 ± 5.1 HU) and higher signal to noise and image to noise ratios in the proximal coronary arteries. IRIS reduces image noise and contrast-to-noise ratio in coronary CT angiography, thus providing potential for reducing radiation exposure.

  2. Multigrid iterative method with adaptive spatial support for computed tomography reconstruction from few-view data

    Science.gov (United States)

    Lee, Ping-Chang

    2014-03-01

    Computed tomography (CT) plays a key role in modern medical system, whether it be for diagnosis or therapy. As an increased risk of cancer development is associated with exposure to radiation, reducing radiation exposure in CT becomes an essential issue. Based on the compressive sensing (CS) theory, iterative based method with total variation (TV) minimization is proven to be a powerful framework for few-view tomographic image reconstruction. Multigrid method is an iterative method for solving both linear and nonlinear systems, especially when the system contains a huge number of components. In medical imaging, image background is often defined by zero intensity, thus attaining spatial support of the image, which is helpful for iterative reconstruction. In the proposed method, the image support is not considered as a priori knowledge. Rather, it evolves during the reconstruction process. Based on the CS framework, we proposed a multigrid method with adaptive spatial support constraint. The simultaneous algebraic reconstruction (SART) with TV minimization is implemented for comparison purpose. The numerical result shows: 1. Multigrid method has better performance while less than 60 views of projection data were used, 2. Spatial support highly improves the CS reconstruction, and 3. When few views of projection data were measured, our method performs better than the SART+TV method with spatial support constraint.

  3. Normalizing computed tomography data reconstructed with different filter kernels: effect on emphysema quantification

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo-Estrella, Leticia; Prokop, Mathias [Radboud University Nijmegen Medical Center, Geert Grooteplein 10 (route 767), P.O. Box 9101, Nijmegen (766) (Netherlands); Lynch, David A.; Stinson, Douglas; Zach, Jordan [National Jewish Health, Denver, CO (United States); Judy, Philip F. [Brigham and Women' s Hospital, Boston, MA (United States); Ginneken, Bram van; Rikxoort, Eva M. van [Radboud University Nijmegen Medical Center, Geert Grooteplein 10 (route 767), P.O. Box 9101, Nijmegen (766) (Netherlands); Fraunhofer MEVIS, Bremen (Germany)

    2016-02-15

    To propose and evaluate a method to reduce variability in emphysema quantification among different computed tomography (CT) reconstructions by normalizing CT data reconstructed with varying kernels. We included 369 subjects from the COPDGene study. For each subject, spirometry and a chest CT reconstructed with two kernels were obtained using two different scanners. Normalization was performed by frequency band decomposition with hierarchical unsharp masking to standardize the energy in each band to a reference value. Emphysema scores (ES), the percentage of lung voxels below -950 HU, were computed before and after normalization. Bland-Altman analysis and correlation between ES and spirometry before and after normalization were compared. Two mixed cohorts, containing data from all scanners and kernels, were created to simulate heterogeneous acquisition parameters. The average difference in ES between kernels decreased for the scans obtained with both scanners after normalization (7.7 ± 2.7 to 0.3 ± 0.7; 7.2 ± 3.8 to -0.1 ± 0.5). Correlation coefficients between ES and FEV{sub 1}, and FEV{sub 1}/FVC increased significantly for the mixed cohorts. Normalization of chest CT data reduces variation in emphysema quantification due to reconstruction filters and improves correlation between ES and spirometry. (orig.)

  4. Learned Shrinkage Approach for Low-Dose Reconstruction in Computed Tomography

    Directory of Open Access Journals (Sweden)

    Joseph Shtok

    2013-01-01

    Full Text Available We propose a direct nonlinear reconstruction algorithm for Computed Tomography (CT, designed to handle low-dose measurements. It involves the filtered back-projection and adaptive nonlinear filtering in both the projection and the image domains. The filter is an extension of the learned shrinkage method by Hel-Or and Shaked to the case of indirect observations. The shrinkage functions are learned using a training set of reference CT images. The optimization is performed with respect to an error functional in the image domain that combines the mean square error with a gradient-based penalty, promoting image sharpness. Our numerical simulations indicate that the proposed algorithm can manage well with noisy measurements, allowing a dose reduction by a factor of 4, while reducing noise and streak artifacts in the FBP reconstruction, comparable to the performance of a statistically based iterative algorithm.

  5. Monte Carlo evaluation of the Filtered Back Projection method for image reconstruction in proton computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G.A.P., E-mail: cirrone@lns.infn.it [Laboratori Nazionali del Sud - National Instiute for Nuclear Physics INFN (INFN-LNS), Via S.Sofia 64, 95100 Catania (Italy); Bucciolini, M. [Department of ' Fisiopatologia Clinica' , University of Florence, V.le Morgagni 85, I-50134 Florence (Italy); Bruzzi, M. [Energetic Department, University of Florence, Via S. Marta 3, I-50139 Florence (Italy); Candiano, G. [Laboratorio di Tecnologie Oncologiche HSR, Giglio Contrada, Pietrapollastra-Pisciotto, 90015 Cefalu, Palermo (Italy); Civinini, C. [National Institute for Nuclear Physics INFN, Section of Florence, Via G. Sansone 1, Sesto Fiorentino, I-50019 Florence (Italy); Cuttone, G. [Laboratori Nazionali del Sud - National Instiute for Nuclear Physics INFN (INFN-LNS), Via S.Sofia 64, 95100 Catania (Italy); Guarino, P. [Nuclear Engineering Department, University of Palermo, Via... Palermo (Italy); Laboratori Nazionali del Sud - National Instiute for Nuclear Physics INFN (INFN-LNS), Via S.Sofia 64, 95100 Catania (Italy); Lo Presti, D. [Physics Department, University of Catania, Via S. Sofia 64, I-95123, Catania (Italy); Mazzaglia, S.E. [Laboratori Nazionali del Sud - National Instiute for Nuclear Physics INFN (INFN-LNS), Via S.Sofia 64, 95100 Catania (Italy); Pallotta, S. [Department of ' Fisiopatologia Clinica' , University of Florence, V.le Morgagni 85, I-50134 Florence (Italy); Randazzo, N. [National Institute for Nuclear Physics INFN, Section of Catania, Via S.Sofia 64, 95123 Catania (Italy); Sipala, V. [National Institute for Nuclear Physics INFN, Section of Catania, Via S.Sofia 64, 95123 Catania (Italy); Physics Department, University of Catania, Via S. Sofia 64, I-95123, Catania (Italy); Stancampiano, C. [National Institute for Nuclear Physics INFN, Section of Catania, Via S.Sofia 64, 95123 Catania (Italy); and others

    2011-12-01

    In this paper the use of the Filtered Back Projection (FBP) Algorithm, in order to reconstruct tomographic images using the high energy (200-250 MeV) proton beams, is investigated. The algorithm has been studied in detail with a Monte Carlo approach and image quality has been analysed and compared with the total absorbed dose. A proton Computed Tomography (pCT) apparatus, developed by our group, has been fully simulated to exploit the power of the Geant4 Monte Carlo toolkit. From the simulation of the apparatus, a set of tomographic images of a test phantom has been reconstructed using the FBP at different absorbed dose values. The images have been evaluated in terms of homogeneity, noise, contrast, spatial and density resolution.

  6. Waveform Inversion with Source Encoding for Breast Sound Speed Reconstruction in Ultrasound Computed Tomography

    Science.gov (United States)

    Wang, Kun; Matthews, Thomas; Anis, Fatima; Li, Cuiping; Duric, Neb; Anastasio, Mark A.

    2016-01-01

    Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the sound speed distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Both computer-simulation and experimental phantom studies are conducted to demonstrate the use of the WISE method. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden. PMID:25768816

  7. Waveform inversion with source encoding for breast sound speed reconstruction in ultrasound computed tomography.

    Science.gov (United States)

    Wang, Kun; Matthews, Thomas; Anis, Fatima; Li, Cuiping; Duric, Neb; Anastasio, Mark A

    2015-03-01

    Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the sound speed distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Both computer simulation and experimental phantom studies are conducted to demonstrate the use of the WISE method. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden.

  8. High performance graphics processor based computed tomography reconstruction algorithms for nuclear and other large scale applications.

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, Edward Steven,

    2013-09-01

    The goal of this work is to develop a fast computed tomography (CT) reconstruction algorithm based on graphics processing units (GPU) that achieves significant improvement over traditional central processing unit (CPU) based implementations. The main challenge in developing a CT algorithm that is capable of handling very large datasets is parallelizing the algorithm in such a way that data transfer does not hinder performance of the reconstruction algorithm. General Purpose Graphics Processing (GPGPU) is a new technology that the Science and Technology (S&T) community is starting to adopt in many fields where CPU-based computing is the norm. GPGPU programming requires a new approach to algorithm development that utilizes massively multi-threaded environments. Multi-threaded algorithms in general are difficult to optimize since performance bottlenecks occur that are non-existent in single-threaded algorithms such as memory latencies. If an efficient GPU-based CT reconstruction algorithm can be developed; computational times could be improved by a factor of 20. Additionally, cost benefits will be realized as commodity graphics hardware could potentially replace expensive supercomputers and high-end workstations. This project will take advantage of the CUDA programming environment and attempt to parallelize the task in such a way that multiple slices of the reconstruction volume are computed simultaneously. This work will also take advantage of the GPU memory by utilizing asynchronous memory transfers, GPU texture memory, and (when possible) pinned host memory so that the memory transfer bottleneck inherent to GPGPU is amortized. Additionally, this work will take advantage of GPU-specific hardware (i.e. fast texture memory, pixel-pipelines, hardware interpolators, and varying memory hierarchy) that will allow for additional performance improvements.

  9. Evaluation of the Bresenham algorithm for image reconstruction with ultrasound computer tomography

    Science.gov (United States)

    Spieß, Norbert; Zapf, Michael; Ruiter, Nicole V.

    2011-03-01

    At Karlsruhe Institute of Technology a 3D Ultrasound Computer Tomography (USCT) system is under development for early breast cancer detection. With 3.5 million of acquired raw data and up to one billion voxels for one image, the reconstruction of breast volumes may last for weeks in highest possible resolution. The currently applied backprojection algorithm, based on the synthetic aperture focusing technique (SAFT), offers only limited potential for further decrease of the reconstruction time. An alternative reconstruction method could apply signal detected data and rasterizes the backprojected ellipsoids directly. A well-known rasterization algorithm is the Bresenham algorithm, which was originally designed to rasterize lines. In this work an existing Bresenham concept to rasterize circles is extended to comply with the requirements of image reconstruction in USCT: the circle rasterization was adapted to rasterize spheres and extended to floating point parameterization. The evaluation of the algorithm showed that the quality of the rasterization is comparable to the original algorithm. The achieved performance of the circle and sphere rasterization algorithm was 12MVoxel/s and 3.5MVoxel/s. When taking the performance increase due to the reduced A-Scan data into account, an acceleration of factor 28 in comparison to the currently applied algorithm could be reached. For future work the presented rasterization algorithm offers additional potential for further speed up.

  10. Noise reduction in computed tomography using a multiplicative continuous-time image reconstruction method

    Science.gov (United States)

    Yamaguchi, Yusaku; Kojima, Takeshi; Yoshinaga, Tetsuya

    2016-03-01

    In clinical X-ray computed tomography (CT), filtered back-projection as a transform method and iterative reconstruction such as the maximum-likelihood expectation-maximization (ML-EM) method are known methods to reconstruct tomographic images. As the other reconstruction method, we have presented a continuous-time image reconstruction (CIR) system described by a nonlinear dynamical system, based on the idea of continuous methods for solving tomographic inverse problems. Recently, we have also proposed a multiplicative CIR system described by differential equations based on the minimization of a weighted Kullback-Leibler divergence. We prove theoretically that the divergence measure decreases along the solution to the CIR system, for consistent inverse problems. In consideration of the noisy nature of projections in clinical CT, the inverse problem belongs to the category of ill-posed problems. The performance of a noise-reduction scheme for a new (previously developed) CIR system was investigated by means of numerical experiments using a circular phantom image. Compared to the conventional CIR and the ML-EM methods, the proposed CIR method has an advantage on noisy projection with lower signal-to-noise ratios in terms of the divergence measure on the actual image under the same common measure observed via the projection data. The results lead to the conclusion that the multiplicative CIR method is more effective and robust for noise reduction in CT compared to the ML-EM as well as conventional CIR methods.

  11. Metal artifact reduction in cone beam computed tomography using forward projected reconstruction information

    Energy Technology Data Exchange (ETDEWEB)

    Meilinger, Manuel [Regensburg Univ. (Germany). CIML Group; Siemens Healthcare, Erlangen (Germany); Schmidgunst, Christian; Schuetz, Oliver [Siemens Healthcare, Erlangen (Germany); Lang, Elmar W. [Regensburg Univ. (Germany). CIML Group

    2011-07-01

    In this work we present a new method to reduce artifacts, produced by high-density objects, especially metal implants, in X-ray cone beam computed tomography (CBCT). These artifacts influence clinical diagnostics and treatments using CT data, if metal objects are located in the field of view (FOV). Our novel method reduces metal artifacts by virtually replacing the metal objects with tissue objects of the same shape. First, the considered objects must be segmented in the original 2D projection data as well as in a reconstructed 3D volume. The attenuation coefficients of the segmented voxels are replaced with adequate attenuation coefficients of tissue (or water), then the required parts of the volume are projected onto the segmented 2D pixels, to replace the original information. This corrected 2D data can then be reconstructed with reduced artifacts, i.e. all metal objects virtually vanished. After the reconstruction, the segmented 3D metal objects were re-inserted into the corrected 3D volume. Our method was developed for mobile C-arm CBCTs; as it is necessary that they are of low weight, the C-arm results in unpredictable distortion. This misalignment between the original 2D data and the forward projection of the reconstructed 3D volume must be adjusted before the correction of the segmented 2D pixels. We applied this technique to clinical data and will now present the results. (orig.)

  12. Temporal sparsity exploiting nonlocal regularization for 4D computed tomography reconstruction.

    Science.gov (United States)

    Kazantsev, Daniil; Guo, Enyu; Kaestner, Anders; Lionheart, William R B; Bent, Julian; Withers, Philip J; Lee, Peter D

    2016-01-01

    X-ray imaging applications in medical and material sciences are frequently limited by the number of tomographic projections collected. The inversion of the limited projection data is an ill-posed problem and needs regularization. Traditional spatial regularization is not well adapted to the dynamic nature of time-lapse tomography since it discards the redundancy of the temporal information. In this paper, we propose a novel iterative reconstruction algorithm with a nonlocal regularization term to account for time-evolving datasets. The aim of the proposed nonlocal penalty is to collect the maximum relevant information in the spatial and temporal domains. With the proposed sparsity seeking approach in the temporal space, the computational complexity of the classical nonlocal regularizer is substantially reduced (at least by one order of magnitude). The presented reconstruction method can be directly applied to various big data 4D (x, y, z+time) tomographic experiments in many fields. We apply the proposed technique to modelled data and to real dynamic X-ray microtomography (XMT) data of high resolution. Compared to the classical spatio-temporal nonlocal regularization approach, the proposed method delivers reconstructed images of improved resolution and higher contrast while remaining significantly less computationally demanding.

  13. A promising limited angular computed tomography reconstruction via segmentation based regional enhancement and total variation minimization

    Science.gov (United States)

    Zhang, Wenkun; Zhang, Hanming; Li, Lei; Wang, Linyuan; Cai, Ailong; Li, Zhongguo; Yan, Bin

    2016-08-01

    X-ray computed tomography (CT) is a powerful and common inspection technique used for the industrial non-destructive testing. However, large-sized and heavily absorbing objects cause the formation of artifacts because of either the lack of specimen penetration in specific directions or the acquisition of data from only a limited angular range of views. Although the sparse optimization-based methods, such as the total variation (TV) minimization method, can suppress artifacts to some extent, reconstructing the images such that they converge to accurate values remains difficult because of the deficiency in continuous angular data and inconsistency in the projections. To address this problem, we use the idea of regional enhancement of the true values and suppression of the illusory artifacts outside the region to develop an efficient iterative algorithm. This algorithm is based on the combination of regional enhancement of the true values and TV minimization for the limited angular reconstruction. In this algorithm, the segmentation approach is introduced to distinguish the regions of different image knowledge and generate the support mask of the image. A new regularization term, which contains the support knowledge to enhance the true values of the image, is incorporated into the objective function. Then, the proposed optimization model is solved by variable splitting and the alternating direction method efficiently. A compensation approach is also designed to extract useful information from the initial projections and thus reduce false segmentation result and correct the segmentation support and the segmented image. The results obtained from comparing both simulation studies and real CT data set reconstructions indicate that the proposed algorithm generates a more accurate image than do the other reconstruction methods. The experimental results show that this algorithm can produce high-quality reconstructed images for the limited angular reconstruction and suppress

  14. Effects of reconstruction parameters on image noise and spatial resolution in cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Wan; Lee, Chang-Lae; Cho, Hyo-Min; Park, Hye-Suk; Kim, Dae-Hong; Choi, Yu-Na; Kim, Hee-Joung [Yonsei University, Wonju (Korea, Republic of)

    2011-10-15

    CBCT (cone-beam computed tomography) is a promising modality in many medical applications due to the properties of fast volume coverage, lower radiation dose, easy hardware implementation, and higher spatial resolution. Recently, attention is being paid to the noise and resolution relationship for CBCT. In a CBCT system, image noise and spatial resolution play very important roles in image quality. However, there have not been many works to evaluate the relationship between the image noise and the spatial resolution in CBCT. In this study, we evaluated the effects of reconstruction parameters, such as the characteristics of the filter, the number of projections, and the voxel size, on the image noise and the spatial resolution in a CBCT system. The simulated projection data of a Catphan 600 phantom were reconstructed using the FDK (Feldkamp) algorithm. To evaluate the image noise and the spatial resolution, we calculated the COV (coefficient of variation) of the attenuation coefficient and the MTF (modulation transfer function) in axial images. Five reconstruction filters, Ram-Lak, Shepp-Logan, Cosine, Hamming, and Hann, were used to reconstruct the images. Different numbers of projections for a circular scan of 360 degrees and different voxel sizes were used to reconstruct the images to evaluate their effect on image noise and spatial resolution. The image noise given by the Hann filter was the lowest and the spatial resolution given by the Ram-Lak filter was the highest. The image noise was decreased as functions of the number of projections and the voxel size. The spatial resolution was increased as a function of the number of projections and decreased as a function of the voxel size. The results of this study show the relationship between the image noise and the spatial resolution in a CBCT system and the characteristics of the reconstruction factors for trade-off between the image noise and the spatial resolution. It can also provide information of the image

  15. Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction

    Institute of Scientific and Technical Information of China (English)

    Diomidis Botsikas; Isabelle Barnaure; Sylvain Terraz; Christoph D Becker; Anastasia Kalovidouri; Xavier Montet

    2016-01-01

    AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction(SAFIRE?) in comparison with a standard MDCT protocol. Fiftythree consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/m L(Accupaque 350~?) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively(SAFIRE?-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio(CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups.RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol(P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different(P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group(P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups(P = 0.9926).CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality.

  16. Feasibility of slice width reduction for spiral cranial computed tomography using iterative image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Haubenreisser, Holger; Fink, Christian; Nance, John W. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Sedlmair, Martin; Schmidt, Bernhard [Siemens Healthcare, Division CT, Forchheim (Germany); Schoenberg, Stefan O. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Henzler, Thomas, E-mail: thomas.henzler@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2014-06-15

    Purpose: To prospectively compare image quality of cranial computed tomography (CCT) examinations with varying slice widths using traditional filtered back projection (FBP) versus sinogram-affirmed iterative image reconstruction (SAFIRE). Materials and methods: 29 consecutive patients (14 men, mean age: 72 ± 17 years) referred for a total of 40 CCT studies were prospectively included. Each CCT raw data set was reconstructed with FBP and SAFIRE at 5 slice widths (1–5 mm; 1 mm increments). Objective image quality was assessed in three predefined regions of the brain (white matter, thalamus, cerebellum) using identical regions of interest (ROIs). Subjective image quality was assessed by 2 experienced radiologists. Objective and subjective image quality parameters were statistically compared between FBP and SAFIRE reconstructions. Results: SAFIRE reconstructions resulted in mean noise reductions of 43.8% in the white matter, 45.6% in the thalamus and 42.0% in the cerebellum (p < 0.01) compared to FBP on non contrast-enhanced 1 mm slice width images. Corresponding mean noise reductions on 1 mm contrast-enhanced studies were 45.7%, 47.3%, and 45.0% in the white matter, thalamus, and cerebellum, respectively (p < 0.01). There was no significant difference in mean attenuation of any region or slice width between the two reconstruction methods (all p > 0.05). Subjective image quality of IR images was mostly rated higher than that of the FBP images. Conclusion: Compared to FBP, SAFIRE provides significant reductions in image noise while increasing subjective image in CCT, particularly when thinner slices are used. Therefore, SAFIRE may allow utilization of thinner slices in CCT, potentially reducing partial volume effects and improving diagnostic accuracy.

  17. Radiation dose reduction in computed tomography-guided lung interventions using an iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Chang, D.H.; Hiss, S.; Borggrefe, J.; Bunck, A.C.; Maintz, D.; Hackenbroch, M. [Cologne University Hospital (Germany). Dept. of Radiology; Mueller, D. [Clinical Science Philips Healthcare GmbH, Munich (Germany). Clinical Science; Hellmich, M. [Cologne University Hospital (Germany). Inst. of Medical Statistics, Informatics and Epidemiology

    2015-10-15

    To compare the radiation doses and image qualities of computed tomography (CT)-guided interventions using a standard-dose CT (SDCT) protocol with filtered back projection and a low-dose CT (LDCT) protocol with both filtered back projection and iterative reconstruction. Image quality and radiation doses (dose-length product and CT dose index) were retrospectively reviewed for 130 patients who underwent CT-guided lung interventions. SDCT at 120 kVp and automatic mA modulation and LDCT at 100 kVp and a fixed exposure were each performed for 65 patients. Image quality was objectively evaluated as the contrast-to-noise ratio and subjectively by two radiologists for noise impression, sharpness, artifacts and diagnostic acceptability on a four-point scale. The groups did not significantly differ in terms of diagnostic acceptability and complication rate. LDCT yielded a median 68.6 % reduction in the radiation dose relative to SDCT. In the LDCT group, iterative reconstruction was superior to filtered back projection in terms of noise reduction and subjective image quality. The groups did not differ in terms of beam hardening artifacts. LDCT was feasible for all procedures and yielded a more than two-thirds reduction in radiation exposure while maintaining overall diagnostic acceptability, safety and precision. The iterative reconstruction algorithm is preferable according to the objective and subjective image quality analyses.

  18. Using additive manufacturing in accuracy evaluation of reconstructions from computed tomography.

    Science.gov (United States)

    Smith, Erin J; Anstey, Joseph A; Venne, Gabriel; Ellis, Randy E

    2013-05-01

    Bone models derived from patient imaging and fabricated using additive manufacturing technology have many potential uses including surgical planning, training, and research. This study evaluated the accuracy of bone surface reconstruction of two diarthrodial joints, the hip and shoulder, from computed tomography. Image segmentation of the tomographic series was used to develop a three-dimensional virtual model, which was fabricated using fused deposition modelling. Laser scanning was used to compare cadaver bones, printed models, and intermediate segmentations. The overall bone reconstruction process had a reproducibility of 0.3 ± 0.4 mm. Production of the model had an accuracy of 0.1 ± 0.1 mm, while the segmentation had an accuracy of 0.3 ± 0.4 mm, indicating that segmentation accuracy was the key factor in reconstruction. Generally, the shape of the articular surfaces was reproduced accurately, with poorer accuracy near the periphery of the articular surfaces, particularly in regions with periosteum covering and where osteophytes were apparent.

  19. Improved misfit function for attenuation and speed reconstruction in ultrasound computed tomography

    Science.gov (United States)

    Pérez-Liva, M.; Udías, J. M.; Herraiz, J. L.

    2017-03-01

    The reconstruction of acoustic attenuation maps for transmission Ultrasound Computed Tomography (USCT) based on the standard least-squares full wave inversion method requires the accurate knowledge of the sound speed map in the region under study. Any deviation in the reconstructed speed maps creates a very significant bias in the attenuation map, as the standard least-squares misfit function is more sensitive to time misalignments than to amplitude differences of the signals. In this work, we propose a generalized misfit function which includes an additional term that accounts for the amplitude differences between the measured and the estimated signals. The functional gradients used to minimize the proposed misfit function were obtained using an adjoint field formulation and the fractional Laplacian wave equation. The forward and backward wave propagation was obtained with the parallelized GPU version of the software k-Wave and the optimization was performed with a line search method. A numerical phantom simulating breast tissue and synthetic noisy data were used to test the performance of the proposed misfit function. The attenuation was reconstructed based on a converged speed map. An edge-preserving regularization method based on total variation was also implemented. To quantify the quality of the results, the mean values and their standard deviations in several regions of interest were analyzed and compared to the reference values. The proposed generalized misfit function decreases considerably the bias in the attenuation map caused by the deviations in the speed map in all the regions of interest analyzed.

  20. 3-D reconstruction of an ancient Egyptian mummy using X-ray computer tomography.

    Science.gov (United States)

    Baldock, C; Hughes, S W; Whittaker, D K; Taylor, J; Davis, R; Spencer, A J; Tonge, K; Sofat, A

    1994-12-01

    Computer tomography has been used to image and reconstruct in 3-D an Egyptian mummy from the collection of the British Museum. This study of Tjentmutengebtiu, a priestess from the 22nd dynasty (945-715 BC) revealed invaluable information of a scientific, Egyptological and palaeopathological nature without mutilation and destruction of the painted cartonnage case or linen wrappings. Precise details on the removal of the brain through the nasal cavity and the viscera from the abdominal cavity were obtained. The nature and composition of the false eyes were investigated. The detailed analysis of the teeth provided a much closer approximation of age at death. The identification of materials used for the various amulets including that of the figures placed in the viscera was graphically demonstrated using this technique.

  1. A Fast local Reconstruction algorithm by selective backprojection for Low-Dose in Dental Computed Tomography

    CERN Document Server

    Bin, Yan; Yu, Han; Feng, Zhang; Chao, Wang Xian; Lei, Li

    2013-01-01

    High radiation dose in computed tomography (CT) scans increases the lifetime risk of cancer, which become a major clinical concern. The backprojection-filtration (BPF) algorithm could reduce radiation dose by reconstructing images from truncated data in a short scan. In dental CT, it could reduce radiation dose for the teeth by using the projection acquired in a short scan, and could avoid irradiation to other part by using truncated projection. However, the limit of integration for backprojection varies per PI-line, resulting in low calculation efficiency and poor parallel performance. Recently, a tent BPF (T-BPF) has been proposed to improve calculation efficiency by rearranging projection. However, the memory-consuming data rebinning process is included. Accordingly, the chose-BPF (C-BPF) algorithm is proposed in this paper. In this algorithm, the derivative of projection is backprojected to the points whose x coordinate is less than that of the source focal spot to obtain the differentiated backprojection...

  2. ROLE OF COMPUTED TOMOGRAPHY AND 3D RECONSTRUCTIONS IN PELVIC RIM AND ACETABULAR FRACTURES

    Directory of Open Access Journals (Sweden)

    Somasekhar

    2015-03-01

    Full Text Available To determine the role of computed tomography and 3D Reconstructions in classification of pelvic rim and acetabular fractures and assessing possible changes in fracture classification . We collected retrospective information in a period of 18 months in our institution , of patients with pelvic injuries considering --- demographic data , radiological examination performed and the moment when it was performed , fracture classification and management . In 12 cases ( 54% there were isolated pelvic rim fr actures and 7 cases of isolated acetabular fractures ( 32% and 3 cases ( 14% involving both . After the CT scan was obtained , the initial classification was changed in five cases ( 22 . 7% . Tridimensional CT based modeling is very helpful in the classificati on of pelvic fractures and is a complement of the plain X - ray .

  3. Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model

    DEFF Research Database (Denmark)

    Wolf, Paul A.; Jørgensen, Jakob Sauer; Schmidt, Taly G.

    2013-01-01

    A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true...

  4. Monoenergetic computed tomography reconstructions reduce beam hardening artifacts from dental restorations.

    Science.gov (United States)

    Stolzmann, Paul; Winklhofer, Sebastian; Schwendener, Nicole; Alkadhi, Hatem; Thali, Michael J; Ruder, Thomas D

    2013-09-01

    The aim of this study was to assess the potential of monoenergetic computed tomography (CT) images to reduce beam hardening artifacts in comparison to standard CT images of dental restoration on dental post-mortem CT (PMCT). Thirty human decedents (15 male, 58 ± 22 years) with dental restorations were examined using standard single-energy CT (SECT) and dual-energy CT (DECT). DECT data were used to generate monoenergetic CT images, reflecting the X-ray attenuation at energy levels of 64, 69, 88 keV, and at an individually adjusted optimal energy level called OPTkeV. Artifact reduction and image quality of SECT and monoenergetic CT were assessed objectively and subjectively by two blinded readers. Subjectively, beam artifacts decreased visibly in 28/30 cases after monoenergetic CT reconstruction. Inter- and intra-reader agreement was good (k = 0.72, and k = 0.73 respectively). Beam hardening artifacts decreased significantly with increasing monoenergies (repeated-measures ANOVA p < 0.001). Artifact reduction was greatest on monoenergetic CT images at OPTkeV. Mean OPTkeV was 108 ± 17 keV. OPTkeV yielded the lowest difference between CT numbers of streak artifacts and reference tissues (-163 HU). Monoenergetic CT reconstructions significantly reduce beam hardening artifacts from dental restorations and improve image quality of post-mortem dental CT.

  5. [Weighted-averaging multi-planar reconstruction method for multi-detector row computed tomography].

    Science.gov (United States)

    Aizawa, Mitsuhiro; Nishikawa, Keiichi; Sasaki, Keita; Kobayashi, Norio; Yama, Mitsuru; Sano, Tsukasa; Murakami, Shin-ichi

    2012-01-01

    Development of multi-detector row computed tomography (MDCT) has enabled three-dimensions (3D) scanning with minute voxels. Minute voxels improve spatial resolution of CT images. At the same time, however, they increase image noise. Multi-planar reconstruction (MPR) is one of effective 3D-image processing techniques. The conventional MPR technique can adjust slice thickness of MPR images. When a thick slice is used, the image noise is decreased. In this case, however, spatial resolution is deteriorated. In order to deal with this trade-off problem, we have developed the weighted-averaging multi-planar reconstruction (W-MPR) technique to control the balance between the spatial resolution and noise. The weighted-average is determined by the Gaussian-type weighting function. In this study, we compared the performance of W-MPR with that of conventional simple-addition-averaging MPR. As a result, we could confirm that W-MPR can decrease the image noise without significant deterioration of spatial resolution. W-MPR can adjust freely the weight for each slice by changing the shape of the weighting function. Therefore, W-MPR can allow us to select a proper balance of spatial resolution and noise and at the same time produce suitable MPR images for observation of targeted anatomical structures.

  6. Acoustic property reconstruction of a pygmy sperm whale (Kogia breviceps) forehead based on computed tomography imaging.

    Science.gov (United States)

    Song, Zhongchang; Xu, Xiao; Dong, Jianchen; Xing, Luru; Zhang, Meng; Liu, Xuecheng; Zhang, Yu; Li, Songhai; Berggren, Per

    2015-11-01

    Computed tomography (CT) imaging and sound experimental measurements were used to reconstruct the acoustic properties (density, velocity, and impedance) of the forehead tissues of a deceased pygmy sperm whale (Kogia breviceps). The forehead was segmented along the body axis and sectioned into cross section slices, which were further cut into sample pieces for measurements. Hounsfield units (HUs) of the corresponding measured pieces were obtained from CT scans, and regression analyses were conducted to investigate the linear relationships between the tissues' HUs and velocity, and HUs and density. The distributions of the acoustic properties of the head at axial, coronal, and sagittal cross sections were reconstructed, revealing that the nasal passage system was asymmetric and the cornucopia-shaped spermaceti organ was in the right nasal passage, surrounded by tissues and airsacs. A distinct dense theca was discovered in the posterior-dorsal area of the melon, which was characterized by low velocity in the inner core and high velocity in the outer region. Statistical analyses revealed significant differences in density, velocity, and acoustic impedance between all four structures, melon, spermaceti organ, muscle, and connective tissue (p acoustic properties of the forehead tissues provide important information for understanding the species' bioacoustic characteristics.

  7. Analysis of bite marks in foodstuffs by computer tomography (cone beam CT)--3D reconstruction.

    Science.gov (United States)

    Marques, Jeidson; Musse, Jamilly; Caetano, Catarina; Corte-Real, Francisco; Corte-Real, Ana Teresa

    2013-12-01

    The use of three-dimensional (3D) analysis of forensic evidence is highlighted in comparison with traditional methods. This three-dimensional analysis is based on the registration of the surface from a bitten object. The authors propose to use Cone Beam Computed Tomography (CBCT), which is used in dental practice, in order to study the surface and interior of bitten objects and dental casts of suspects. In this study, CBCT is applied to the analysis of bite marks in foodstuffs, which may be found in a forensic case scenario. 6 different types of foodstuffs were used: chocolate, cheese, apple, chewing gum, pizza and tart (flaky pastry and custard). The food was bitten into and dental casts of the possible suspects were made. The dental casts and bitten objects were registered using an x-ray source and the CBCT equipment iCAT® (Pennsylvania, EUA). The software InVivo5® (Anatomage Inc, EUA) was used to visualize and analyze the tomographic slices and 3D reconstructions of the objects. For each material an estimate of its density was assessed by two methods: HU values and specific gravity. All the used materials were successfully reconstructed as good quality 3D images. The relative densities of the materials in study were compared. Amongst the foodstuffs, the chocolate had the highest density (median value 100.5 HU and 1,36 g/cm(3)), while the pizza showed to have the lowest (median value -775 HU and 0,39 g/cm(3)), on both scales. Through tomographic slices and three-dimensional reconstructions it was possible to perform the metric analysis of the bite marks in all the foodstuffs, except for the pizza. These measurements could also be obtained from the dental casts. The depth of the bite mark was also successfully determined in all the foodstuffs except for the pizza. Cone Beam Computed Tomography has the potential to become an important tool for forensic sciences, namely for the registration and analysis of bite marks in foodstuffs that may be found in a crime

  8. Iterative reconstruction for quantitative computed tomography analysis of emphysema: consistent results using different tube currents

    Directory of Open Access Journals (Sweden)

    Yamashiro T

    2015-02-01

    Full Text Available Tsuneo Yamashiro,1 Tetsuhiro Miyara,1 Osamu Honda,2 Noriyuki Tomiyama,2 Yoshiharu Ohno,3 Satoshi Noma,4 Sadayuki Murayama1 On behalf of the ACTIve Study Group 1Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan; 2Department of Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan; 3Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan; 4Department of Radiology, Tenri Hospital, Tenri, Nara, Japan Purpose: To assess the advantages of iterative reconstruction for quantitative computed tomography (CT analysis of pulmonary emphysema. Materials and methods: Twenty-two patients with pulmonary emphysema underwent chest CT imaging using identical scanners with three different tube currents: 240, 120, and 60 mA. Scan data were converted to CT images using Adaptive Iterative Dose Reduction using Three Dimensional Processing (AIDR3D and a conventional filtered-back projection mode. Thus, six scans with and without AIDR3D were generated per patient. All other scanning and reconstruction settings were fixed. The percent low attenuation area (LAA%; < -950 Hounsfield units and the lung density 15th percentile were automatically measured using a commercial workstation. Comparisons of LAA% and 15th percentile results between scans with and without using AIDR3D were made by Wilcoxon signed-rank tests. Associations between body weight and measurement errors among these scans were evaluated by Spearman rank correlation analysis. Results: Overall, scan series without AIDR3D had higher LAA% and lower 15th percentile values than those with AIDR3D at each tube current (P<0.0001. For scan series without AIDR3D, lower tube currents resulted in higher LAA% values and lower 15th percentiles. The extent of emphysema was significantly different between each pair among scans when not using AIDR3D (LAA%, P<0.0001; 15th percentile, P<0.01, but was not

  9. The effects of computed tomography with iterative reconstruction on solid pulmonary nodule volume quantification.

    Directory of Open Access Journals (Sweden)

    Martin J Willemink

    Full Text Available BACKGROUND: The objectives of this study were to evaluate the influence of iterative reconstruction (IR on pulmonary nodule volumetry with chest computed tomography (CT. METHODS: Twenty patients (12 women and 8 men, mean age 61.9, range 32-87 underwent evaluation of pulmonary nodules with a 64-slice CT-scanner. Data were reconstructed using filtered back projection (FBP and IR (Philips Healthcare, iDose(4-levels 2, 4 and 6 at similar radiation dose. Volumetric nodule measurements were performed with semi-automatic software on thin slice reconstructions. Only solid pulmonary nodules were measured, no additional selection criteria were used for the nature of nodules. For intra-observer and inter-observer variability, measurements were performed once by one observer and twice by another observer. Algorithms were compared using the concordance correlation-coefficient (pc and Friedman-test, and post-hoc analysis with the Wilcoxon-signed ranks-test with Bonferroni-correction (significance-level p<0.017. RESULTS: Seventy-eight nodules were present including 56 small nodules (volume<200 mm(3, diameter<8 mm and 22 large nodules (volume≥200 mm(3, diameter≥8 mm. No significant differences in measured pulmonary nodule volumes between FBP, iDose(4-levels 2, 4 and 6 were found in both small nodules and large nodules. FBP and iDose(4-levels 2, 4 and 6 were correlated with pc-values of 0.98 or higher for both small and large nodules. Pc-values of intra-observer and inter-observer variability were 0.98 or higher. CONCLUSIONS: Measurements of solid pulmonary nodule volume measured with standard-FBP were comparable with IR, regardless of the IR-level and no significant differences between measured volumes of both small and large solid nodules were found.

  10. A simple Fourier transform-based reconstruction formula for photoacoustic computed tomography with a circular or spherical measurement geometry

    CERN Document Server

    Wang, Kun

    2012-01-01

    Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging modality that has great potential for a wide range of biomedical imaging applications. In this Note, we derive a hybrid reconstruction formula that is mathematically exact and operates on a data function that is expressed in the temporal frequency and spatial domains. This formula explicitly reveals new insights into how the spatial frequency components of the sought-after object function are determined by the temporal frequency components of the data function measured with a circular or spherical measurement geometry in two- and three-dimensional implementations of PACT, respectively. The structure of the reconstruction formula is surprisingly simple compared with existing Fourier-domain reconstruction formulae. It also yields a straightforward numerical implementation that is robust and two orders of magnitude more computationally efficient than filtered backprojection algorithms.

  11. Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions.

    Science.gov (United States)

    Goodenberger, Martin H; Wagner-Bartak, Nicolaus A; Gupta, Shiva; Liu, Xinming; Yap, Ramon Q; Sun, Jia; Tamm, Eric P; Jensen, Corey T

    2017-08-12

    The purpose of this study was to compare abdominopelvic computed tomography images reconstructed with adaptive statistical iterative reconstruction-V (ASIR-V) with model-based iterative reconstruction (Veo 3.0), ASIR, and filtered back projection (FBP). Abdominopelvic computed tomography scans for 36 patients (26 males and 10 females) were reconstructed using FBP, ASIR (80%), Veo 3.0, and ASIR-V (30%, 60%, 90%). Mean ± SD patient age was 32 ± 10 years with mean ± SD body mass index of 26.9 ± 4.4 kg/m. Images were reviewed by 2 independent readers in a blinded, randomized fashion. Hounsfield unit, noise, and contrast-to-noise ratio (CNR) values were calculated for each reconstruction algorithm for further comparison. Phantom evaluation of low-contrast detectability (LCD) and high-contrast resolution was performed. Adaptive statistical iterative reconstruction-V 30%, ASIR-V 60%, and ASIR 80% were generally superior qualitatively compared with ASIR-V 90%, Veo 3.0, and FBP (P V 90% showed superior LCD and had the highest CNR in the liver, aorta, and, pancreas, measuring 7.32 ± 3.22, 11.60 ± 4.25, and 4.60 ± 2.31, respectively, compared with the next best series of ASIR-V 60% with respective CNR values of 5.54 ± 2.39, 8.78 ± 3.15, and 3.49 ± 1.77 (P V 30% and ASIR-V 60% provided the best combination of qualitative and quantitative performance. Adaptive statistical iterative reconstruction 80% was equivalent qualitatively, but demonstrated inferior spatial resolution and LCD.

  12. The effects of iterative reconstruction and kernel selection on quantitative computed tomography measures of lung density.

    Science.gov (United States)

    Rodriguez, Alfonso; Ranallo, Frank N; Judy, Philip F; Fain, Sean B

    2017-06-01

    To determine the effects of iterative reconstruction (IR) and high-frequency kernels on quantitative computed tomography (qCT) density measures at reduced X-ray dose. The COPDGene 2 Phantom (CTP 698, The Phantom Laboratory, Salem, NY) with four embedded lung mimicking foam densities (12lb, 20lb, and 4lb), as well as water, air, and acrylic reference inserts, was imaged using a GE 64 slice CT750 HD scanner in helical mode with four current-time products ranging from 12 to 100 mAs. The raw acquired data were reconstructed using standard (STD - low frequency) and Bone (high frequency) kernels with filtered back projection (FBP), 100% ASiR, and Veo reconstruction algorithms. The reference density inserts were manually segmented using Slicer3D (www.slicer.org), and the mean, standard deviation, and histograms of the segmented regions were generated using Fiji (http://fiji.sc/Fiji) for each reconstruction. Measurements of threshold values placed on the cumulative frequency distribution of voxels determined by these measured histograms at 5%, PD5phant , and 15%, PD15phant , (analogous to the relative area below -950 HU (RA-950) and percent density 15 (PD15) in human lung emphysema quantification, respectively), were also performed. The use of high-resolution kernels in conjunction with ASiR and Veo did not significantly affect the mean Hounsfield units (HU) of each of the density standards (density regions. The density histogram became more sharply peaked, and standard deviation was reduced for IR, directly effecting density thresholds, PD5phant and PD15phant, placed on the cumulative frequency distribution of each region in the phantom, which serve as analogs to RA-950 and PD15 typically used in lung density quantitation. The combination of high-frequency kernels (Bone) with ASiR mitigates this effect and preserves density measures derived from the image histogram. Moreover, previous studies have shown improved accuracy of qCT airway measures of wall thickness (WT) and

  13. [Novel method of noise power spectrum measurement for computed tomography images with adaptive iterative reconstruction method].

    Science.gov (United States)

    Nishimaru, Eiji; Ichikawa, Katsuhiro; Hara, Takanori; Terakawa, Shoichi; Yokomachi, Kazushi; Fujioka, Chikako; Kiguchi, Masao; Ishifuro, Minoru

    2012-01-01

    Adaptive iterative reconstruction techniques (IRs) can decrease image noise in computed tomography (CT) and are expected to contribute to reduction of the radiation dose. To evaluate the performance of IRs, the conventional two-dimensional (2D) noise power spectrum (NPS) is widely used. However, when an IR provides an NPS value drop at all spatial frequency (which is similar to NPS changes by dose increase), the conventional method cannot evaluate the correct noise property because the conventional method does not correspond to the volume data natures of CT images. The purpose of our study was to develop a new method for NPS measurements that can be adapted to IRs. Our method utilized thick multi-planar reconstruction (MPR) images. The thick images are generally made by averaging CT volume data in a direction perpendicular to a MPR plane (e.g. z-direction for axial MPR plane). By using this averaging technique as a cutter for 3D-NPS, we can obtain adequate 2D-extracted NPS (eNPS) from 3D NPS. We applied this method to IR images generated with adaptive iterative dose reduction 3D (AIDR-3D, Toshiba) to investigate the validity of our method. A water phantom with 24 cm-diameters was scanned at 120 kV and 200 mAs with a 320-row CT (Acquilion One, Toshiba). From the results of study, the adequate thickness of MPR images for eNPS was more than 25.0 mm. Our new NPS measurement method utilizing thick MPR images was accurate and effective for evaluating noise reduction effects of IRs.

  14. Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

    Energy Technology Data Exchange (ETDEWEB)

    Nikneshan, Nikneshan; Aval, Shadi Hamidi [Dept. of Dental and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bakhshalian, Neema [Dept. of Advanced Periodontology, School of Dentistry, University of Southern California, Los Angeles (United States); Shahab, Shahriyar [Dept. of Dental and Maxillofacial Radiology, School of Dentistry, Shahed University of Medical Sciences, Tehran (Korea, Republic of); Mohammadpour, Mahdis [Dept. of Dental and Maxillofacial Radiology, School of Dentistry, Qazvin University of Medical Sciences, Qazvin (Iran, Islamic Republic of); SarikhanI, Soodeh [Dept. of Dental and Maxillofacial Radiology, School of Dentistry, Golestan University of Medical Sciences, Golestan (Iran, Islamic Republic of)

    2014-12-15

    This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., 0 degrees), +10 degrees, +12 degrees, -12 degrees, and -10 degrees with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of -12 degrees, -0.66 to -0.11 at -10 degrees, -0.51 to +0.19 at 0 degrees, -0.64 to +0.08 at +10 degrees, and -0.64 to +0.1 at +12 degrees. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Changing the slice orientation in the range of -12 degrees to +12 degrees reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

  15. Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bastos, Luana Costa; Campos, Paulo Sergio Flores, E-mail: bastosluana@ymail.com [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Fac. de Odontologia. Dept. de Radiologia Oral e Maxilofacial; Ramos-Perez, Flavia Maria de Moraes [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Fac. de Odontologia. Dept. de Clinica e Odontologia Preventiva; Pontual, Andrea dos Anjos [Universidade Federal de Pernambuco (UFPE), Camaragibe, PE (Brazil). Fac. de Odontologia. Dept. de Radiologia Oral; Almeida, Solange Maria [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Fac. de Odontologia. Dept. de Radiologia Oral

    2013-11-15

    This study was conducted to investigate how well cone-beam computed tomography (CBCT) can detect simulated cavitary defects in condyles, and to test the influence of the reconstruction protocols. Defects were created with spherical diamond burs (numbers 1013, 1016, 3017) in superior and / or posterior surfaces of twenty condyles. The condyles were scanned, and cross-sectional reconstructions were performed with nine different protocols, based on slice thickness (0.2, 0.6, 1.0 mm) and on the filters (original image, Sharpen Mild, S9) used. Two observers evaluated the defects, determining their presence and location. Statistical analysis was carried out using simple Kappa coefficient and McNemar’s test to check inter- and intra-rater reliability. The chi-square test was used to compare the rater accuracy. Analysis of variance (Tukey's test) assessed the effect of the protocols used. Kappa values for inter- and intra-rater reliability demonstrate almost perfect agreement. The proportion of correct answers was significantly higher than that of errors for cavitary defects on both condyle surfaces (p < 0.01). Only in identifying the defects located on the posterior surface was it possible to observe the influence of the 1.0 mm protocol thickness and no filter, which showed a significantly lower value. Based on the results of the current study, the technique used was valid for identifying the existence of cavities in the condyle surface. However, the protocol of a 1.0 mm-thick slice and no filter proved to be the worst method for identifying the defects on the posterior surface. (author)

  16. A pseudo-discrete algebraic reconstruction technique (PDART) prior image-based suppression of high density artifacts in computed tomography

    Science.gov (United States)

    Pua, Rizza; Park, Miran; Wi, Sunhee; Cho, Seungryong

    2016-12-01

    We propose a hybrid metal artifact reduction (MAR) approach for computed tomography (CT) that is computationally more efficient than a fully iterative reconstruction method, but at the same time achieves superior image quality to the interpolation-based in-painting techniques. Our proposed MAR method, an image-based artifact subtraction approach, utilizes an intermediate prior image reconstructed via PDART to recover the background information underlying the high density objects. For comparison, prior images generated by total-variation minimization (TVM) algorithm, as a realization of fully iterative approach, were also utilized as intermediate images. From the simulation and real experimental results, it has been shown that PDART drastically accelerates the reconstruction to an acceptable quality of prior images. Incorporating PDART-reconstructed prior images in the proposed MAR scheme achieved higher quality images than those by a conventional in-painting method. Furthermore, the results were comparable to the fully iterative MAR that uses high-quality TVM prior images.

  17. Performance of Hull-Detection Algorithms For Proton Computed Tomography Reconstruction

    CERN Document Server

    Schultze, Blake; Censor, Yair; Schulte, Reinhard; Schubert, Keith Evan

    2014-01-01

    Proton computed tomography (pCT) is a novel imaging modality developed for patients receiving proton radiation therapy. The purpose of this work was to investigate hull-detection algorithms used for preconditioning of the large and sparse linear system of equations that needs to be solved for pCT image reconstruction. The hull-detection algorithms investigated here included silhouette/space carving (SC), modified silhouette/space carving (MSC), and space modeling (SM). Each was compared to the cone-beam version of filtered backprojection (FBP) used for hull-detection. Data for testing these algorithms included simulated data sets of a digital head phantom and an experimental data set of a pediatric head phantom obtained with a pCT scanner prototype at Loma Linda University Medical Center. SC was the fastest algorithm, exceeding the speed of FBP by more than 100 times. FBP was most sensitive to the presence of noise. Ongoing work will focus on optimizing threshold parameters in order to define a fast and effic...

  18. A reconstruction method for cone-beam differential x-ray phase-contrast computed tomography.

    Science.gov (United States)

    Fu, Jian; Velroyen, Astrid; Tan, Renbo; Zhang, Junwei; Chen, Liyuan; Tapfer, Arne; Bech, Martin; Pfeiffer, Franz

    2012-09-10

    Most existing differential phase-contrast computed tomography (DPC-CT) approaches are based on three kinds of scanning geometries, described by parallel-beam, fan-beam and cone-beam. Due to the potential of compact imaging systems with magnified spatial resolution, cone-beam DPC-CT has attracted significant interest. In this paper, we report a reconstruction method based on a back-projection filtration (BPF) algorithm for cone-beam DPC-CT. Due to the differential nature of phase contrast projections, the algorithm restrains from differentiation of the projection data prior to back-projection, unlike BPF algorithms commonly used for absorption-based CT data. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a micro-focus x-ray tube source. Moreover, the numerical simulation and experimental results demonstrate that the proposed method can deal with several classes of truncated cone-beam datasets. We believe that this feature is of particular interest for future medical cone-beam phase-contrast CT imaging applications.

  19. Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Willemink, Martin J.; Leiner, Tim; Jong, Pim A. de; Nievelstein, Rutger A.J.; Schilham, Arnold M.R. [Utrecht University Medical Center, Department of Radiology, P.O. Box 85500, Utrecht (Netherlands); Heer, Linda M. de [Cardiothoracic Surgery, Utrecht (Netherlands); Budde, Ricardo P.J. [Utrecht University Medical Center, Department of Radiology, P.O. Box 85500, Utrecht (Netherlands); Gelre Hospital, Department of Radiology, Apeldoorn (Netherlands)

    2013-06-15

    To present the results of a systematic literature search aimed at determining to what extent the radiation dose can be reduced with iterative reconstruction (IR) for cardiopulmonary and body imaging with computed tomography (CT) in the clinical setting and what the effects on image quality are with IR versus filtered back-projection (FBP) and to provide recommendations for future research on IR. We searched Medline and Embase from January 2006 to January 2012 and included original research papers concerning IR for CT. The systematic search yielded 380 articles. Forty-nine relevant studies were included. These studies concerned: the chest(n = 26), abdomen(n = 16), both chest and abdomen(n = 1), head(n = 4), spine(n = 1), and no specific area (n = 1). IR reduced noise and artefacts, and it improved subjective and objective image quality compared to FBP at the same dose. Conversely, low-dose IR and normal-dose FBP showed similar noise, artefacts, and subjective and objective image quality. Reported dose reductions ranged from 23 to 76 % compared to locally used default FBP settings. However, IR has not yet been investigated for ultra-low-dose acquisitions with clinical diagnosis and accuracy as endpoints. Benefits of IR include improved subjective and objective image quality as well as radiation dose reduction while preserving image quality. Future studies need to address the value of IR in ultra-low-dose CT with clinically relevant endpoints. (orig.)

  20. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography.

    Science.gov (United States)

    May, Matthias S; Wüst, Wolfgang; Brand, Michael; Stahl, Christian; Allmendinger, Thomas; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2011-07-01

    We sought to evaluate the image quality of iterative reconstruction in image space (IRIS) in half-dose (HD) datasets compared with full-dose (FD) and HD filtered back projection (FBP) reconstruction in abdominal computed tomography (CT). To acquire data with FD and HD simultaneously, contrast-enhanced abdominal CT was performed with a dual-source CT system, both tubes operating at 120 kV, 100 ref.mAs, and pitch 0.8. Three different image datasets were reconstructed from the raw data: Standard FD images applying FBP which served as reference, HD images applying FBP and HD images applying IRIS. For the HD data sets, only data from 1 tube detector-system was used. Quantitative image quality analysis was performed by measuring image noise in tissue and air. Qualitative image quality was evaluated according to the European Guidelines on Quality criteria for CT. Additional assessment of artifacts, lesion conspicuity, and edge sharpness was performed. : Image noise in soft tissue was substantially decreased in HD-IRIS (-3.4 HU, -22%) and increased in HD-FBP (+6.2 HU, +39%) images when compared with the reference (mean noise, 15.9 HU). No significant differences between the FD-FBP and HD-IRIS images were found for the visually sharp anatomic reproduction, overall diagnostic acceptability (P = 0.923), lesion conspicuity (P = 0.592), and edge sharpness (P = 0.589), while HD-FBP was rated inferior. Streak artifacts and beam hardening was significantly more prominent in HD-FBP while HD-IRIS images exhibited a slightly different noise pattern. Direct intrapatient comparison of standard FD body protocols and HD-IRIS reconstruction suggest that the latest iterative reconstruction algorithms allow for approximately 50% dose reduction without deterioration of the high image quality necessary for confident diagnosis.

  1. A compressed sensing based reconstruction algorithm for synchrotron source propagation-based X-ray phase contrast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Melli, Seyed Ali, E-mail: sem649@mail.usask.ca [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Wahid, Khan A. [Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, SK (Canada); Babyn, Paul [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada); Montgomery, James [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Snead, Elisabeth [Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK (Canada); El-Gayed, Ali [College of Medicine, University of Saskatchewan, Saskatoon, SK (Canada); Pettitt, Murray; Wolkowski, Bailey [College of Agriculture and Bioresources, University of Saskatchewan, Saskatoon, SK (Canada); Wesolowski, Michal [Department of Medical Imaging, University of Saskatchewan, Saskatoon, SK (Canada)

    2016-01-11

    Synchrotron source propagation-based X-ray phase contrast computed tomography is increasingly used in pre-clinical imaging. However, it typically requires a large number of projections, and subsequently a large radiation dose, to produce high quality images. To improve the applicability of this imaging technique, reconstruction algorithms that can reduce the radiation dose and acquisition time without degrading image quality are needed. The proposed research focused on using a novel combination of Douglas–Rachford splitting and randomized Kaczmarz algorithms to solve large-scale total variation based optimization in a compressed sensing framework to reconstruct 2D images from a reduced number of projections. Visual assessment and quantitative performance evaluations of a synthetic abdomen phantom and real reconstructed image of an ex-vivo slice of canine prostate tissue demonstrate that the proposed algorithm is competitive in reconstruction process compared with other well-known algorithms. An additional potential benefit of reducing the number of projections would be reduction of time for motion artifact to occur if the sample moves during image acquisition. Use of this reconstruction algorithm to reduce the required number of projections in synchrotron source propagation-based X-ray phase contrast computed tomography is an effective form of dose reduction that may pave the way for imaging of in-vivo samples.

  2. Joint Reconstruction of Absorbed Optical Energy Density and Sound Speed Distribution in Photoacoustic Computed Tomography: A numerical Investigation

    CERN Document Server

    Huang, Chao; Schoonover, Robert W; Wang, Lihong V; Anastasio, Mark A

    2015-01-01

    Photoacoustic computed tomography (PACT) is a rapidly emerging bioimaging modality that seeks to reconstruct an estimate of the absorbed optical energy density within an object. Conventional PACT image reconstruction methods assume a constant speed-of-sound (SOS), which can result in image artifacts when acoustic aberrations are significant. It has been demonstrated that incorporating knowledge of an object's SOS distribution into a PACT image reconstruction method can improve image quality. However, in many cases, the SOS distribution cannot be accurately and/or conveniently estimated prior to the PACT experiment. Because variations in the SOS distribution induce aberrations in the measured photoacoustic wavefields, certain information regarding an object's SOS distribution is encoded in the PACT measurement data. Based on this observation, a joint reconstruction (JR) problem has been proposed in which the SOS distribution is concurrently estimated along with the sought-after absorbed optical energy density ...

  3. High-performance image reconstruction in fluorescence tomography on desktop computers and graphics hardware.

    Science.gov (United States)

    Freiberger, Manuel; Egger, Herbert; Liebmann, Manfred; Scharfetter, Hermann

    2011-11-01

    Image reconstruction in fluorescence optical tomography is a three-dimensional nonlinear ill-posed problem governed by a system of partial differential equations. In this paper we demonstrate that a combination of state of the art numerical algorithms and a careful hardware optimized implementation allows to solve this large-scale inverse problem in a few seconds on standard desktop PCs with modern graphics hardware. In particular, we present methods to solve not only the forward but also the non-linear inverse problem by massively parallel programming on graphics processors. A comparison of optimized CPU and GPU implementations shows that the reconstruction can be accelerated by factors of about 15 through the use of the graphics hardware without compromising the accuracy in the reconstructed images.

  4. Overall anatomical features and clinical value of the sacral nerve in high resolution computed tomography reconstruction

    Institute of Scientific and Technical Information of China (English)

    LIN Jing-fu; WANG Yan-hua; JIANG Bao-guo; ZHANG Pei-xun; LI Yan-ying; ZHANG Dian-ying

    2010-01-01

    Background Sacral nerve injury is a common complication of pelvic or sacral fractures. As the sacral nerve courser within the sacrum and has a complex relationship with the surrounding tissues, different parts of the sacral plexus injury have similar clinical symptoms and signs. Since lack of specific imaging technique in the diagnosis of sacral nerve injury,especially on multi-segment, multi-site, how to determine the preoperative location and extent of the sacral nerve injury accurately becomes a concem of the general orthopaedic and images practitioners. This study was conducted to gain an insight into the overall anatomical features of the sacral nerve (SN) on the same slice in high resolution computed tomography (HRCT) reconstruction and to determine the value of this information for the clinical diagnosis of related diseases.Methods Fifty healthy volunteers and 30 patients (40 sides) with SN lesions confirmed by surgery were scanned using a 16-slice helical CT scanner (Light Speed, GE, USA). Among the patients, 6 with intervertebral disk hernia (6 sides), 8with spinal stenosis (12 sides), 11 with pelvic trauma (14 sides), 4 with pelvic malignancies (6 sides), and 1 with sacral vertebral tuberculosis (2 sides). The SN multiplanar reconstruction was performed using a UNIX-based SCD4.1workstation where the image was set on the same slice. All images were stored in the Digital Imaging and Communications in Medicine format. The display of nerves in different sections was analyzed using a five-graded scale with coordinate curves of each individual score. The overall anatomic features visible on the slice were analyzed and the abnormalities of the lesions were studied.Results The image of the same slice clearly revealed the shape, running direction, thickness, tension and adjacent anatomy of the S1-S4 nerves. The rank of display rates in different sections was: outward-rotated oblique sagittal >outward-rotated oblique coronal > oblique coronal plane > coronal

  5. Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans

    NARCIS (Netherlands)

    Al-Rawi, B.; Hassan, B.; Vandenberge, B.; Jacobs, R.

    2010-01-01

    The use of three-dimensional (3D) models of the dentition obtained from cone beam computed tomography (CBCT) is becoming increasingly more popular in dentistry. A recent trend is to replace the traditional dental casts with digital CBCT models for diagnosis, treatment planning and simulation. The ac

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special ... the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT ...

  7. Reduction of metal artifact in single photon-counting computed tomography by spectral-driven iterative reconstruction technique.

    Directory of Open Access Journals (Sweden)

    Radin A Nasirudin

    Full Text Available The exciting prospect of Spectral CT (SCT using photon-counting detectors (PCD will lead to new techniques in computed tomography (CT that take advantage of the additional spectral information provided. We introduce a method to reduce metal artifact in X-ray tomography by incorporating knowledge obtained from SCT into a statistical iterative reconstruction scheme. We call our method Spectral-driven Iterative Reconstruction (SPIR.The proposed algorithm consists of two main components: material decomposition and penalized maximum likelihood iterative reconstruction. In this study, the spectral data acquisitions with an energy-resolving PCD were simulated using a Monte-Carlo simulator based on EGSnrc C++ class library. A jaw phantom with a dental implant made of gold was used as an object in this study. A total of three dental implant shapes were simulated separately to test the influence of prior knowledge on the overall performance of the algorithm. The generated projection data was first decomposed into three basis functions: photoelectric absorption, Compton scattering and attenuation of gold. A pseudo-monochromatic sinogram was calculated and used as input in the reconstruction, while the spatial information of the gold implant was used as a prior. The results from the algorithm were assessed and benchmarked with state-of-the-art reconstruction methods.Decomposition results illustrate that gold implant of any shape can be distinguished from other components of the phantom. Additionally, the result from the penalized maximum likelihood iterative reconstruction shows that artifacts are significantly reduced in SPIR reconstructed slices in comparison to other known techniques, while at the same time details around the implant are preserved. Quantitatively, the SPIR algorithm best reflects the true attenuation value in comparison to other algorithms.It is demonstrated that the combination of the additional information from Spectral CT and

  8. Level-set reconstruction algorithm for ultrafast limited-angle X-ray computed tomography of two-phase flows.

    Science.gov (United States)

    Bieberle, M; Hampel, U

    2015-06-13

    Tomographic image reconstruction is based on recovering an object distribution from its projections, which have been acquired from all angular views around the object. If the angular range is limited to less than 180° of parallel projections, typical reconstruction artefacts arise when using standard algorithms. To compensate for this, specialized algorithms using a priori information about the object need to be applied. The application behind this work is ultrafast limited-angle X-ray computed tomography of two-phase flows. Here, only a binary distribution of the two phases needs to be reconstructed, which reduces the complexity of the inverse problem. To solve it, a new reconstruction algorithm (LSR) based on the level-set method is proposed. It includes one force function term accounting for matching the projection data and one incorporating a curvature-dependent smoothing of the phase boundary. The algorithm has been validated using simulated as well as measured projections of known structures, and its performance has been compared to the algebraic reconstruction technique and a binary derivative of it. The validation as well as the application of the level-set reconstruction on a dynamic two-phase flow demonstrated its applicability and its advantages over other reconstruction algorithms. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  9. Studies of Sensitivity in the Dictionary Learning Approach to Computed Tomography: Simplifying the Reconstruction Problem, Rotation, and Scale

    DEFF Research Database (Denmark)

    Soltani, Sara

    In this report, we address the problem of low-dose tomographic image reconstruction using dictionary priors learned from training images. In our recent work [22] dictionary learning is used to incorporate priors from training images and construct a dictionary, and then the reconstruction problem...... is formulated in a convex optimization framework by looking for a solution with a sparse representation in the subspace spanned by the dictionary. The work in [22] has shown that using learned dictionaries in computed tomography can lead to superior image reconstructions comparing to classical methods. Our...... formulation in [22] enforces that the solution is an exact representation by the dictionary; in this report, we investigate this requirement. Furthermore, the underlying assumption that the scale and orientation of the training images are consistent with the unknown image of interest may not be realistic. We...

  10. Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model

    CERN Document Server

    Wolf, Paul A; Schmidt, Taly G; Sidky, Emil Y

    2012-01-01

    A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true object in the noiseless case, projection data were generated from an object assuming this model and using the system matrix. Monte Carlo simulations were performed to provide more realistic data of a phantom with varying smoothness across the field of view. Reconstructions were performed across a sweep of two primary design parameters. The results demonstrate that the algorithm recovers the object in a noiseless simulation case. While the algorithm assumes a specific blurring model, the results suggest that the algorithm may provide high reconstruction accuracy even when the object does not match the assumed blurring model. Generally, increased values of the blurring parameter and TV weighting parameters reduced noi...

  11. Morphometric study of maxillary sinus by computed tomography. Assessment of sinus floor bone reconstruction

    OpenAIRE

    2012-01-01

    Rehabilitation with dental implants in posterior maxilla is difficult because of the presence of maxillary sinus with anatomical variations. The aim of this research was to evaluate the sinus volume to install one or more implants without invading the sinus membrane. Forty (40) maxillary sinuses were evaluated in 22 skulls by computed tomography measuring in the axial, coronal and sagittal slice. The sinus were classified according to the remaining alveolar bone and a dental implant in the pl...

  12. Bayesian 3D X-ray computed tomography image reconstruction with a scaled Gaussian mixture prior model

    Science.gov (United States)

    Wang, Li; Gac, Nicolas; Mohammad-Djafari, Ali

    2015-01-01

    In order to improve quality of 3D X-ray tomography reconstruction for Non Destructive Testing (NDT), we investigate in this paper hierarchical Bayesian methods. In NDT, useful prior information on the volume like the limited number of materials or the presence of homogeneous area can be included in the iterative reconstruction algorithms. In hierarchical Bayesian methods, not only the volume is estimated thanks to the prior model of the volume but also the hyper parameters of this prior. This additional complexity in the reconstruction methods when applied to large volumes (from 5123 to 81923 voxels) results in an increasing computational cost. To reduce it, the hierarchical Bayesian methods investigated in this paper lead to an algorithm acceleration by Variational Bayesian Approximation (VBA) [1] and hardware acceleration thanks to projection and back-projection operators paralleled on many core processors like GPU [2]. In this paper, we will consider a Student-t prior on the gradient of the image implemented in a hierarchical way [3, 4, 1]. Operators H (forward or projection) and Ht (adjoint or back-projection) implanted in multi-GPU [2] have been used in this study. Different methods will be evalued on synthetic volume "Shepp and Logan" in terms of quality and time of reconstruction. We used several simple regularizations of order 1 and order 2. Other prior models also exists [5]. Sometimes for a discrete image, we can do the segmentation and reconstruction at the same time, then the reconstruction can be done with less projections.

  13. 3D algebraic iterative reconstruction for cone-beam x-ray differential phase-contrast computed tomography.

    Science.gov (United States)

    Fu, Jian; Hu, Xinhua; Velroyen, Astrid; Bech, Martin; Jiang, Ming; Pfeiffer, Franz

    2015-01-01

    Due to the potential of compact imaging systems with magnified spatial resolution and contrast, cone-beam x-ray differential phase-contrast computed tomography (DPC-CT) has attracted significant interest. The current proposed FDK reconstruction algorithm with the Hilbert imaginary filter will induce severe cone-beam artifacts when the cone-beam angle becomes large. In this paper, we propose an algebraic iterative reconstruction (AIR) method for cone-beam DPC-CT and report its experiment results. This approach considers the reconstruction process as the optimization of a discrete representation of the object function to satisfy a system of equations that describes the cone-beam DPC-CT imaging modality. Unlike the conventional iterative algorithms for absorption-based CT, it involves the derivative operation to the forward projections of the reconstructed intermediate image to take into account the differential nature of the DPC projections. This method is based on the algebraic reconstruction technique, reconstructs the image ray by ray, and is expected to provide better derivative estimates in iterations. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a mini-focus x-ray tube source. It is shown that the proposed method can reduce the cone-beam artifacts and performs better than FDK under large cone-beam angles. This algorithm is of interest for future cone-beam DPC-CT applications.

  14. Image reconstruction based on total-variation minimization and alternating direction method in linear scan computed tomography

    Institute of Scientific and Technical Information of China (English)

    Zhang Han-Ming; Wang Lin-Yuan; Yah Bin; Li Lei; Xi Xiao-Qi; Lu Li-Zhong

    2013-01-01

    Linear scan computed tomography (LCT) is of great benefit to online industrial scanning and security inspection due to its characteristics of straight-line source trajectory and high scanning speed.However,in practical applications of LCT,there are challenges to image reconstruction due to limited-angle and insufficient data.In this paper,a new reconstruction algorithm based on total-variation (TV) minimization is developed to reconstruct images from limited-angle and insufficient data in LCT.The main idea of our approach is to reformulate a TV problem as a linear equality constrained problem where the objective function is separable,and then minimize its augmented Lagrangian function by using alternating direction method (ADM) to solve subproblems.The proposed method is robust and efficient in the task of reconstruction by showing the convergence of ADM.The numerical simulations and real data reconstructions show that the proposed reconstruction method brings reasonable performance and outperforms some previous ones when applied to an LCT imaging problem.

  15. Quantitative computed tomography and cranial burr holes: a model to evaluate the quality of cranial reconstruction in humans.

    Science.gov (United States)

    Worm, Paulo Valdeci; Ferreira, Nelson Pires; Ferreira, Marcelo Paglioli; Kraemer, Jorge Luiz; Lenhardt, Rene; Alves, Ronnie Peterson Marcondes; Wunderlich, Ricardo Castilho; Collares, Marcus Vinicius Martins

    2012-05-01

    Current methods to evaluate the biologic development of bone grafts in human beings do not quantify results accurately. Cranial burr holes are standardized critical bone defects, and the differences between bone powder and bone grafts have been determined in numerous experimental studies. This study evaluated quantitative computed tomography (QCT) as a method to objectively measure cranial bone density after cranial reconstruction with autografts. In each of 8 patients, 2 of 4 surgical burr holes were reconstructed with autogenous wet bone powder collected during skull trephination, and the other 2 holes, with a circular cortical bone fragment removed from the inner table of the cranial bone flap. After 12 months, the reconstructed areas and a sample of normal bone were studied using three-dimensional QCT; bone density was measured in Hounsfield units (HU). Mean (SD) bone density was 1535.89 (141) HU for normal bone (P < 0.0001), 964 (176) HU for bone fragments, and 453 (241) HU for bone powder (P < 0.001). As expected, the density of the bone fragment graft was consistently greater than that of bone powder. Results confirm the accuracy and reproducibility of QCT, already demonstrated for bone in other locations, and suggest that it is an adequate tool to evaluate cranial reconstructions. The combination of QCT and cranial burr holes is an excellent model to accurately measure the quality of new bone in cranial reconstructions and also seems to be an appropriate choice of experimental model to clinically test any cranial bone or bone substitute reconstruction.

  16. Usefulness of the evaluation of preoperative sternal shape for reconstruction of pectus excavatum using three-dimensional computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Masahiko; Kondoh, Shohji; Kondoh, Yoshiaki; Akabane, Genichiroh [Nagano Children`s Hospital (Japan); Matsuo, Kiyoshi

    1997-04-01

    In the reconstruction of the pectus excavatum deformity, when sternal growth must be considered, it is desirable that osteotomy of the sternum be performed if necessary. From this standpoint, we evaluate the preoperative sternal shape using three-dimensional computed tomography. The sternum is outlined on the mid-sagittal plane, and the curved portions are examined. Preoperatively, the sternums are classified into 3 groups based on the number of curved portions. On the basis of these observations, we determine the position and degree of the sternal osteotomy and, if necessary, combined sternal osteotomy and augmentation using resected cartilage. We think that this method is useful not only for reconstruction of pectus excavatum but also in evaluating the postoperative shape of the thorax. (author)

  17. Statistical models and regularization strategies in statistical image reconstruction of low-dose X-ray computed tomography: a survey

    CERN Document Server

    Zhang, Hao; Ma, Jianhua; Lu, Hongbing; Liang, Zhengrong

    2014-01-01

    Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose X-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method for various clinical tasks. According to the maximum a posterior (MAP) estimation, the SIR methods can be typically formulated by an objective function consisting of two terms: (1) data-fidelity (or equivalently, data-fitting or data-mismatch) term modeling the statistics of projection measurements, and (2) regularization (or equivalently, prior or penalty) term reflecting prior knowledge or expectation on the characteristics of the image to be reconstructed. Existing SIR methods for low-dose CT can be divided into two groups: (1) those that use calibrated transmitted photon counts (before log-transform) with penalized maximum likelihood (pML) criterion, and (2) those that use calibrated line-integrals (after log-transform) with penalized weighted least-squares (PWLS) criterion. Accurate s...

  18. Stabilizing dual-energy X-ray computed tomography reconstructions using patch-based regularization

    CERN Document Server

    Tracey, Brian H

    2014-01-01

    Recent years have seen growing interest in exploiting dual- and multi-energy measurements in computed tomography (CT) in order to characterize material properties as well as object shape. Material characterization is performed by decomposing the scene into constitutive basis functions, such as Compton scatter and photoelectric absorption functions. While well motivated physically, the joint recovery of the spatial distribution of photoelectric and Compton properties is severely complicated by the fact that the data are several orders of magnitude more sensitive to Compton scatter coefficients than to photoelectric absorption, so small errors in Compton estimates can create large artifacts in the photoelectric estimate. To address these issues, we propose a model-based iterative approach which uses patch-based regularization terms to stabilize inversion of photoelectric coefficients, and solve the resulting problem though use of computationally attractive Alternating Direction Method of Multipliers (ADMM) solu...

  19. Registration of planar bioluminescence to magnetic resonance and x-ray computed tomography images as a platform for the development of bioluminescence tomography reconstruction algorithms.

    Science.gov (United States)

    Beattie, Bradley J; Klose, Alexander D; Le, Carl H; Longo, Valerie A; Dobrenkov, Konstantine; Vider, Jelena; Koutcher, Jason A; Blasberg, Ronald G

    2009-01-01

    The procedures we propose make possible the mapping of two-dimensional (2-D) bioluminescence image (BLI) data onto a skin surface derived from a three-dimensional (3-D) anatomical modality [magnetic resonance (MR) or computed tomography (CT)] dataset. This mapping allows anatomical information to be incorporated into bioluminescence tomography (BLT) reconstruction procedures and, when applied using sources visible to both optical and anatomical modalities, can be used to evaluate the accuracy of those reconstructions. Our procedures, based on immobilization of the animal and a priori determined fixed projective transforms, should be more robust and accurate than previously described efforts, which rely on a poorly constrained retrospectively determined warping of the 3-D anatomical information. Experiments conducted to measure the accuracy of the proposed registration procedure found it to have a mean error of 0.36+/-0.23 mm. Additional experiments highlight some of the confounds that are often overlooked in the BLT reconstruction process, and for two of these confounds, simple corrections are proposed.

  20. Three-dimensional reconstruction of subject-specific knee joint using computed tomography and magnetic resonance imaging image data fusions.

    Science.gov (United States)

    Dong, Yuefu; Mou, Zhifang; Huang, Zhenyu; Hu, Guanghong; Dong, Yinghai; Xu, Qingrong

    2013-10-01

    Three-dimensional reconstruction of human body from a living subject can be considered as the first step toward promoting virtual human project as a tool in clinical applications. This study proposes a detailed protocol for building subject-specific three-dimensional model of knee joint from a living subject. The computed tomography and magnetic resonance imaging image data of knee joint were used to reconstruct knee structures, including bones, skin, muscles, cartilages, menisci, and ligaments. They were fused to assemble the complete three-dimensional knee joint. The procedure was repeated three times with respect to three different methods of reference landmarks. The accuracy of image fusion in accordance with different landmarks was evaluated and compared with each other. The complete three-dimensional knee joint, which included 21 knee structures, was accurately developed. The choice of external or anatomical landmarks was not crucial to improve image fusion accuracy for three-dimensional reconstruction. Further work needs to be done to explore the value of the reconstructed three-dimensional knee joint for its biomechanics and kinematics.

  1. Bayesian 3D X-ray computed tomography image reconstruction with a scaled Gaussian mixture prior model

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Li; Gac, Nicolas; Mohammad-Djafari, Ali [Laboratoire des Signaux et Systèmes 3, Rue Joliot-Curie 91192 Gif sur Yvette (France)

    2015-01-13

    In order to improve quality of 3D X-ray tomography reconstruction for Non Destructive Testing (NDT), we investigate in this paper hierarchical Bayesian methods. In NDT, useful prior information on the volume like the limited number of materials or the presence of homogeneous area can be included in the iterative reconstruction algorithms. In hierarchical Bayesian methods, not only the volume is estimated thanks to the prior model of the volume but also the hyper parameters of this prior. This additional complexity in the reconstruction methods when applied to large volumes (from 512{sup 3} to 8192{sup 3} voxels) results in an increasing computational cost. To reduce it, the hierarchical Bayesian methods investigated in this paper lead to an algorithm acceleration by Variational Bayesian Approximation (VBA) [1] and hardware acceleration thanks to projection and back-projection operators paralleled on many core processors like GPU [2]. In this paper, we will consider a Student-t prior on the gradient of the image implemented in a hierarchical way [3, 4, 1]. Operators H (forward or projection) and H{sup t} (adjoint or back-projection) implanted in multi-GPU [2] have been used in this study. Different methods will be evalued on synthetic volume 'Shepp and Logan' in terms of quality and time of reconstruction. We used several simple regularizations of order 1 and order 2. Other prior models also exists [5]. Sometimes for a discrete image, we can do the segmentation and reconstruction at the same time, then the reconstruction can be done with less projections.

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  5. Optimization of pinhole single photon emission computed tomography (pinhole SPECT) reconstruction; Optimisation de la reconstruction en tomographie d'emission monophotonique avec colimateur stenope

    Energy Technology Data Exchange (ETDEWEB)

    Israel-Jost, V

    2006-11-15

    In SPECT small animal imaging, it is highly recommended to accurately model the response of the detector in order to improve the low spatial resolution. The volume to reconstruct is thus obtained both by back-projecting and de-convolving the projections. We chose iterative methods, which permit one to solve the inverse problem independently from the model's complexity. We describe in this work a Gaussian model of point spread function (PSF) whose position, width and maximum are computed according to physical and geometrical parameters. Then we use the rotation symmetry to replace the computation of P projection operators, each one corresponding to one position of the detector around the object, by the computation of only one of them. This is achieved by choosing an appropriate polar discretization, for which we control the angular density of voxels to avoid over-sampling the center of the field of view. Finally, we propose a new family of algorithms, the so-called frequency adapted algorithms, which enable to optimize the reconstruction of a given band in the frequency domain on both the speed of convergence and the quality of the image. (author)

  6. Sparse-view computed tomography image reconstruction via a combination of L(1) and SL(0) regularization.

    Science.gov (United States)

    Qi, Hongliang; Chen, Zijia; Guo, Jingyu; Zhou, Linghong

    2015-01-01

    Low-dose computed tomography reconstruction is an important issue in the medical imaging domain. Sparse-view has been widely studied as a potential strategy. Compressed sensing (CS) method has shown great potential to reconstruct high-quality CT images from sparse-view projection data. Nonetheless, low-contrast structures tend to be blurred by the total variation (TV, L1-norm of the gradient image) regularization. Moreover, TV will produce blocky effects on smooth and edge regions. To overcome this limitation, this study has proposed an iterative image reconstruction algorithm by combining L1 regularization and smoothed L0 (SL0) regularization. SL0 is a smooth approximation of L0 norm and can solve the problem of L0 norm being sensitive to noise. To evaluate the proposed method, both qualitative and quantitative studies were conducted on a digital Shepp-Logan phantom and a real head phantom. Experimental comparative results have indicated that the proposed L1/SL0-POCS algorithm can effectively suppress noise and artifacts, as well as preserve more structural information compared to other existing methods.

  7. Analysis and accurate reconstruction of incomplete data in X-ray differential phase-contrast computed tomography.

    Science.gov (United States)

    Fu, Jian; Tan, Renbo; Chen, Liyuan

    2014-01-01

    X-ray differential phase-contrast computed tomography (DPC-CT) is a powerful physical and biochemical analysis tool. In practical applications, there are often challenges for DPC-CT due to insufficient data caused by few-view, bad or missing detector channels, or limited scanning angular range. They occur quite frequently because of experimental constraints from imaging hardware, scanning geometry, and the exposure dose delivered to living specimens. In this work, we analyze the influence of incomplete data on DPC-CT image reconstruction. Then, a reconstruction method is developed and investigated for incomplete data DPC-CT. It is based on an algebraic iteration reconstruction technique, which minimizes the image total variation and permits accurate tomographic imaging with less data. This work comprises a numerical study of the method and its experimental verification using a dataset measured at the W2 beamline of the storage ring DORIS III equipped with a Talbot-Lau interferometer. The numerical and experimental results demonstrate that the presented method can handle incomplete data. It will be of interest for a wide range of DPC-CT applications in medicine, biology, and nondestructive testing.

  8. The impact of iterative reconstruction in low-dose computed tomography on the evaluation of diffuse interstitial lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Ju; Chung, Myung Jin; Shin, Kyung Eun; Hwang, Hye Sun; Lee, Kyung Soo [Dept. of Radiology nd Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    To evaluate the impact of iterative reconstruction (IR) on the assessment of diffuse interstitial lung disease (DILD) using CT. An American College of Radiology (ACR) phantom (module 4 to assess spatial resolution) was scanned with 10-100 effective mAs at 120 kVp. The images were reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), with blending ratios of 0%, 30%, 70% and 100%, and model-based iterative reconstruction (MBIR), and their spatial resolution was objectively assessed by the line pair structure method. The patient study was based on retrospective interpretation of prospectively acquired data, and it was approved by the institutional review board. Chest CT scans of 23 patients (mean age 64 years) were performed at 120 kVp using 1) standard dose protocol applying 142-275 mA with dose modulation (high-resolution computed tomography [HRCT]) and 2) low-dose protocol applying 20 mA (low dose CT, LDCT). HRCT images were reconstructed with FBP, and LDCT images were reconstructed using FBP, ASIR, and MBIR. Matching images were randomized and independently reviewed by chest radiologists. Subjective assessment of disease presence and radiological diagnosis was made on a 10-point scale. In addition, semi-quantitative results were compared for the extent of abnormalities estimated to the nearest 5% of parenchymal involvement. In the phantom study, ASIR was comparable to FBP in terms of spatial resolution. However, for MBIR, the spatial resolution was greatly decreased under 10 mA. In the patient study, the detection of the presence of disease was not significantly different. The values for area under the curve for detection of DILD by HRCT, FBP, ASIR, and MBIR were as follows: 0.978, 0.979, 0.972, and 0.963. LDCT images reconstructed with FBP, ASIR, and MBIR tended to underestimate reticular or honeycombing opacities (-2.8%, -4.1%, and -5.3%, respectively) and overestimate ground glass opacities (+4.6%, +8.9%, and

  9. Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography

    Science.gov (United States)

    Sang, Yan-Hui; Hu, Hong-Cheng; Lu, Song-He; Wu, Yu-Wei; Li, Wei-Ran; Tang, Zhi-Hui

    2016-01-01

    Background: The accuracy of three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) has been particularly important in dentistry, which will affect the effectiveness of diagnosis, treatment plan, and outcome in clinical practice. The aims of this study were to assess the linear, volumetric, and geometric accuracy of 3D reconstructions from CBCT and to investigate the influence of voxel size and CBCT system on the reconstructions results. Methods: Fifty teeth from 18 orthodontic patients were assigned to three groups as NewTom VG 0.15 mm group (NewTom VG; voxel size: 0.15 mm; n = 17), NewTom VG 0.30 mm group (NewTom VG; voxel size: 0.30 mm; n = 16), and VATECH DCTPRO 0.30 mm group (VATECH DCTPRO; voxel size: 0.30 mm; n = 17). The 3D reconstruction models of the teeth were segmented from CBCT data manually using Mimics 18.0 (Materialise Dental, Leuven, Belgium), and the extracted teeth were scanned by 3Shape optical scanner (3Shape A/S, Denmark). Linear and volumetric deviations were separately assessed by comparing the length and volume of the 3D reconstruction model with physical measurement by paired t-test. Geometric deviations were assessed by the root mean square value of the imposed 3D reconstruction and optical models by one-sample t-test. To assess the influence of voxel size and CBCT system on 3D reconstruction, analysis of variance (ANOVA) was used (α = 0.05). Results: The linear, volumetric, and geometric deviations were −0.03 ± 0.48 mm, −5.4 ± 2.8%, and 0.117 ± 0.018 mm for NewTom VG 0.15 mm group; −0.45 ± 0.42 mm, −4.5 ± 3.4%, and 0.116 ± 0.014 mm for NewTom VG 0.30 mm group; and −0.93 ± 0.40 mm, −4.8 ± 5.1%, and 0.194 ± 0.117 mm for VATECH DCTPRO 0.30 mm group, respectively. There were statistically significant differences between groups in terms of linear measurement (P CBCT data can achieve a high linear, volumetric, and geometric accuracy. Increasing voxel resolution from 0.30 to 0.15 mm does not result

  10. Priori mask guided image reconstruction (p-MGIR) for ultra-low dose cone-beam computed tomography

    Science.gov (United States)

    Park, Justin C.; Zhang, Hao; Chen, Yunmei; Fan, Qiyong; Kahler, Darren L.; Liu, Chihray; Lu, Bo

    2015-11-01

    Recently, the compressed sensing (CS) based iterative reconstruction method has received attention because of its ability to reconstruct cone beam computed tomography (CBCT) images with good quality using sparsely sampled or noisy projections, thus enabling dose reduction. However, some challenges remain. In particular, there is always a tradeoff between image resolution and noise/streak artifact reduction based on the amount of regularization weighting that is applied uniformly across the CBCT volume. The purpose of this study is to develop a novel low-dose CBCT reconstruction algorithm framework called priori mask guided image reconstruction (p-MGIR) that allows reconstruction of high-quality low-dose CBCT images while preserving the image resolution. In p-MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions: (1) where anatomical structures are complex, and (2) where intensities are relatively uniform. The priori mask, which is the key concept of the p-MGIR algorithm, was defined as the matrix that distinguishes between the two separate CBCT regions where the resolution needs to be preserved and where streak or noise needs to be suppressed. We then alternately updated each part of image by solving two sub-minimization problems iteratively, where one minimization was focused on preserving the edge information of the first part while the other concentrated on the removal of noise/artifacts from the latter part. To evaluate the performance of the p-MGIR algorithm, a numerical head-and-neck phantom, a Catphan 600 physical phantom, and a clinical head-and-neck cancer case were used for analysis. The results were compared with the standard Feldkamp-Davis-Kress as well as conventional CS-based algorithms. Examination of the p-MGIR algorithm showed that high-quality low-dose CBCT images can be reconstructed without compromising the image resolution. For both phantom and the patient cases, the p-MGIR is able to achieve a clinically

  11. Effects of particle size, slice thickness, and reconstruction algorithm on coronary calcium quantitation using ultrafast computed tomography

    Science.gov (United States)

    Tang, Weiyi; Detrano, Robert; Kang, Xingping; Garner, D.; Nickerson, Sharon; Desimone, P.; Mahaisavariya, Paiboon; Brundage, B.

    1994-05-01

    The recent emphasis on early diagnosis of coronary artery disease has stimulated research for a reliable and non-invasive screening method. Radiographically detectable coronary calcium has been shown to predict both pathologic and angiographic findings. Ultrafast computed tomography (UFCT), in quantifying coronary calcium, may become an accurate non-invasive method to evaluate the severity of coronary disease. The currently applied index of UFCT coronary calcium amount is the coronary calcium score of Agatston et al. This score has not been thoroughly evaluated as to its accuracy and dependence on scanning parameters. A potential drawback of the score is its dependence on predetermined CT number thresholds. In this investigation we used a chest phantom to determine the effects of particle size, slice thickness, and reconstruction algorithm on the coronary calcium score, and on the calcium mass estimated with a new method which is not dependent on thresholds.

  12. Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography.

    Science.gov (United States)

    Kuo, Yu; Lin, Yi-Yang; Lee, Rheun-Chuan; Lin, Chung-Jung; Chiou, Yi-You; Guo, Wan-Yuo

    2016-08-01

    The purpose of this study was to compare the image noise-reducing abilities of iterative model reconstruction (IMR) with those of traditional filtered back projection (FBP) and statistical iterative reconstruction (IR) in abdominal computed tomography (CT) imagesThis institutional review board-approved retrospective study enrolled 103 patients; informed consent was waived. Urinary bladder (n = 83) and renal cysts (n = 44) were used as targets for evaluating imaging quality. Raw data were retrospectively reconstructed using FBP, statistical IR, and IMR. Objective image noise and signal-to-noise ratio (SNR) were calculated and analyzed using one-way analysis of variance. Subjective image quality was evaluated and analyzed using Wilcoxon signed-rank test with Bonferroni correction.Objective analysis revealed a reduction in image noise for statistical IR compared with that for FBP, with no significant differences in SNR. In the urinary bladder group, IMR achieved up to 53.7% noise reduction, demonstrating a superior performance to that of statistical IR. IMR also yielded a significantly superior SNR to that of statistical IR. Similar results were obtained in the cyst group. Subjective analysis revealed reduced image noise for IMR, without inferior margin delineation or diagnostic confidence.IMR reduced noise and increased SNR to greater degrees than did FBP and statistical IR. Applying the IMR technique to abdominal CT imaging has potential for reducing the radiation dose without sacrificing imaging quality.

  13. Path-based Iterative Reconstruction (PBIR) for X-ray Computed Tomography

    CERN Document Server

    Wu, Meng; Yang, Qiao; Fahrig, Rebecca

    2015-01-01

    Model-based iterative reconstruction (MBIR) techniques have demonstrated many advantages in X-ray CT image reconstruction. The MBIR approach is often modeled as a convex optimization problem including a data fitting function and a penalty function. The tuning parameter value that regulates the strength of the penalty function is critical for achieving good reconstruction results but difficult to choose. In this work, we describe two path seeking algorithms that are capable of efficiently generating a series of MBIR images with different strengths of the penalty function. The root-mean-squared-differences of the proposed path seeking algorithms are below 4 HU throughout the entire reconstruction path. With the efficient path seeking algorithm, we suggest a path-based iterative reconstruction (PBIR) to obtain complete information from the scanned data and reconstruction model.

  14. Reconstructions in ultrasound modulated optical tomography

    KAUST Repository

    Allmaras, Moritz

    2011-01-01

    We introduce a mathematical model for ultrasound modulated optical tomography and present a simple reconstruction scheme for recovering the spatially varying optical absorption coefficient from scanning measurements with narrowly focused ultrasound signals. Computational results for this model show that the reconstruction of sharp features of the absorption coefficient is possible. A formal linearization of the model leads to an equation with a Fredholm operator, which explains the stability observed in our numerical experiments. © de Gruyter 2011.

  15. Computed Tomography Image Origin Identification based on Original Sensor Pattern Noise and 3D Image Reconstruction Algorithm Footprints.

    Science.gov (United States)

    Duan, Yuping; Bouslimi, Dalel; Yang, Guanyu; Shu, Huazhong; Coatrieux, Gouenou

    2016-06-08

    In this paper, we focus on the "blind" identification of the Computed Tomography (CT) scanner that has produced a CT image. To do so, we propose a set of noise features derived from the image chain acquisition and which can be used as CT-Scanner footprint. Basically, we propose two approaches. The first one aims at identifying a CT-Scanner based on an Original Sensor Pattern Noise (OSPN) that is intrinsic to the X-ray detectors. The second one identifies an acquisition system based on the way this noise is modified by its 3D image reconstruction algorithm. As these reconstruction algorithms are manufacturer dependent and kept secret, our features are used as input to train an SVM based classifier so as to discriminate acquisition systems. Experiments conducted on images issued from 15 different CT-Scanner models of 4 distinct manufacturers demonstrate that our system identifies the origin of one CT image with a detection rate of at least 94% and that it achieves better performance than Sensor Pattern Noise (SPN) based strategy proposed for general public camera devices.

  16. Singular value decomposition-based 2D image reconstruction for computed tomography.

    Science.gov (United States)

    Liu, Rui; He, Lu; Luo, Yan; Yu, Hengyong

    2017-01-01

    Singular value decomposition (SVD)-based 2D image reconstruction methods are developed and evaluated for a broad class of inverse problems for which there are no analytical solutions. The proposed methods are fast and accurate for reconstructing images in a non-iterative fashion. The multi-resolution strategy is adopted to reduce the size of the system matrix to reconstruct large images using limited memory capacity. A modified high-contrast Shepp-Logan phantom, a low-contrast FORBILD head phantom, and a physical phantom are employed to evaluate the proposed methods with different system configurations. The results show that the SVD methods can accurately reconstruct images from standard scan and interior scan projections and that they outperform other benchmark methods. The general SVD method outperforms the other SVD methods. The truncated SVD and Tikhonov regularized SVD methods accurately reconstruct a region-of-interest (ROI) from an internal scan with a known sub-region inside the ROI. Furthermore, the SVD methods are much faster and more flexible than the benchmark algorithms, especially in the ROI reconstructions in our experiments.

  17. Assessment of an advanced monoenergetic reconstruction technique in dual-energy computed tomography of head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, Moritz H.; Scholtz, Jan-Erik; Kraft, Johannes; Bauer, Ralf W.; Kaup, Moritz; Dewes, Patricia; Bucher, Andreas M.; Burck, Iris; Lehnert, Thomas; Kerl, J.M.; Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Wagenblast, Jens [University Hospital Frankfurt, Department of Otolaryngology, Head and Neck Surgery, Frankfurt am Main (Germany); Wichmann, Julian L. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2015-08-15

    To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC). DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise. The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M0.3 (3.81; κ = 0.280, P = 0.056). Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers. (orig.)

  18. Skeletal imaging following reconstruction of the posterior cruciate ligament: in vivo comparison of fluoroscopy, radiography, and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Osti, Michael; Benedetto, Karl Peter [Academic Hospital Feldkirch, Department for Trauma Surgery and Sports Traumatology, Feldkirch (Austria); Krawinkel, Alessa [Academic Hospital Feldkirch, Department for Radiology, Feldkirch (Austria)

    2014-12-15

    Intra- and postoperative validation of anatomic footprint replication in posterior cruciate ligament (PCL) reconstruction can be conducted using fluoroscopy, radiography, or computed tomography (CT) scans. However, effectiveness and exposure to radiation of these imaging modalities are unknown. The objective of this study was to evaluate the comparative effectiveness of fluoroscopy, radiography, and CT in detecting femoral and tibial tunnel positions following an all-inside reconstruction of the PCL ligament in vivo. The study design was a retrospective case series. Intraoperative fluoroscopic images, postoperative radiographs, and CT scans were obtained in 50 consecutive patients following single-bundle PCL reconstruction. The centers of the tibial and femoral tunnel apertures were identified and correlated to measurement grid systems. The results of fluoroscopic, radiographic, and CT measurements were compared to each other and accumulated radiation dosages were calculated. Comparing the imaging groups, no statistically significant difference could be detected for the reference of the femoral tunnel to the intercondylar depth and height, for the reference of the tibial tunnel to the mediolateral diameter of the tibial plateau and for the superoinferior distance of the tibial tunnel entry to the tibial plateau and to the former physis line. Effective doses resulting from fluoroscopic, radiographic, and CT exposure averaged 2.9 mSv, standard deviation (±SD) 4.1 mSv, to 1.3 ± 0.8 mSv and to 3.6 ± 1.0 mSv, respectively. Fluoroscopy, radiography, and CT yield approximately equal effectiveness in detecting parameters used for quality validation intra- and postoperatively. An accumulating exposure to radiation must be considered. (orig.)

  19. Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography.

    Science.gov (United States)

    Tu, Sheng; Hu, Fudong; Cai, Wei; Xiao, Liyan; Zhang, Linlin; Zheng, Hong; Jiang, Qiong; Chen, Lianglong

    2017-05-01

    There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). This study aimed to explore the feasibility of detecting polymeric BRS with 3-dimensional reconstruction of BRS images by contrast-enhanced mCT and to determine the optimal imaging settings. BRSs, made of poly-L-lactic acid (PLLA), were implanted in coronary bifurcation models. Five treatments were conducted to examine an optimal condition for imaging BRSs: Baseline treatment, samples were filled with normal saline and scanned with mCT immediately; Treatment-1, -2, -3 and -4, samples were filled with contrast medium and scanned with mCT immediately and 1, 2 and 3 h thereafter, corresponding to soaking time of contrast medium of 0, 1, 2 and 3 h. Compared to Baseline, mCT scanning completely discriminate the scaffold struts from the vascular lumen immediately after filling the samples with contrast agent but not from the vascular wall until the contrast agent soaking time was more than 2 h (Treatment-3 and -4). By setting 10-15 HU as a cut-point of CT values, the scaffold strut detectable rate at Baseline and Teatment-1, -2, -3 and -4 were 1.23 ± 0.31%, 1.65 ± 0.26%, 58.14 ± 12.84%, 97.97 ± 1.43% and 98.90 ± 0.38%, respectively (Treatment-3 vs. Treatment-2, p scaffold struts from the surrounding structures in the phantom samples.

  20. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  1. Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hosch, Waldemar, E-mail: waldemar.hosch@med.uni-heidelberg.de [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Stiller, Wolfram [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Mueller, Dirk [Philips GmbH Healthcare Division, Hamburg (Germany); Gitsioudis, Gitsios [University of Heidelberg, Department of Cardiology, Heidelberg (Germany); Welzel, Johanna; Dadrich, Monika [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Buss, Sebastian J.; Giannitsis, Evangelos [University of Heidelberg, Department of Cardiology, Heidelberg (Germany); Kauczor, Hans U. [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Katus, Hugo A. [University of Heidelberg, Department of Cardiology, Heidelberg (Germany); Korosoglou, Grigorios, E-mail: gkorosoglou@hotmail.com [University of Heidelberg, Department of Cardiology, Heidelberg (Germany)

    2012-11-15

    Purpose: To assess the impact of body mass index (BMI)-adapted protocols and iterative reconstruction algorithms (iDose) on patient radiation exposure and image quality in patients undergoing prospective ECG-triggered 256-slice coronary computed tomography angiography (CCTA). Methods: Image quality and radiation exposure were systematically analyzed in 100 patients. 60 Patients underwent prospective ECG-triggered CCTA using a non-tailored protocol and served as a 'control' group (Group 1: 120 kV, 200 mA s). 40 Consecutive patients with suspected coronary artery disease (CAD) underwent prospective CCTA, using BMI-adapted tube voltage and standard (Group 2: 100/120 kV, 100-200 mA s) versus reduced tube current (Group 3: 100/120 kV, 75-150 mA s). Iterative reconstructions were provided with different iDose levels and were compared to filtered back projection (FBP) reconstructions. Image quality was assessed in consensus of 2 experienced observers and using a 5-grade scale (1 = best to 5 = worse), and signal- and contrast-to-noise ratios (SNR and CNR) were quantified. Results: CCTA was performed without adverse events in all patients (n = 100, heart rate of 47-87 bpm and BMI of 19-38 kg/m{sup 2}). Patients examined using the non-tailored protocol in Group 1 had the highest radiation exposure (3.2 {+-} 0.4 mSv), followed by Group 2 (1.7 {+-} 0.7 mSv) and Group 3 (1.2 {+-} 0.6 mSv) (radiation savings of 47% and 63%, respectively, p < 0.001). Iterative reconstructions provided increased SNR and CNR, particularly when higher iDose level 5 was applied with Multi-Frequency reconstruction (iDose5 MFR) (14.1 {+-} 4.6 versus 21.2 {+-} 7.3 for SNR and 12.0 {+-} 4.2 versus 18.1 {+-} 6.6 for CNR, for FBP versus iDose5 MFR, respectively, p < 0.001). The combination of BMI adaptation with iterative reconstruction reduced radiation exposure and simultaneously improved image quality (subjective image quality of 1.4 {+-} 0.4 versus 1.9 {+-} 0.5 for Group 2 reconstructed using

  2. Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography

    Institute of Scientific and Technical Information of China (English)

    Yan-Hui Sang; Hong-Cheng Hu; Song-He Lu; Yu-Wei Wu; Wei-Ran Li; Zhi-Hui Tang

    2016-01-01

    Background:The accuracy of three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) has been particularly important in dentistry,which will affect the effectiveness of diagnosis,treatment plan,and outcome in clinical practice.The aims of this study were to assess the linear,volumetric,and geometric accuracy of 3D reconstructions from CBCT and to investigate the influence of voxel size and CBCT system on the reconstructions results.Methods:Fifty teeth from 18 orthodontic patients were assigned to three groups as NewTom VG 0.15 mm group (NewTom VG;voxel size:0.15 mm;n =17),NewTom VG 0.30 mm group (NewTom VG;voxel size:0.30 mm;n =16),and VATECH DCTPRO 0.30 mm group (VATECH DCTPRO;voxel size:0.30 mm;n =17).The 3D reconstruction models of the teeth were segmented from CBCT data manually using Mimics 18.0 (Materialise Dental,Leuven,Belgium),and the extracted teeth were scanned by 3Shape optical scanner (3Shape A/S,Denmark).Linear and volumetric deviations were separately assessed by comparing the length and volume of the 3D reconstruction model with physical measurement by paired t-test.Geometric deviations were assessed by the root mean square value of the imposed 3D reconstruction and optical models by one-sample t-test.To assess the influence of voxel size and CBCT system on 3D reconstruction,analysis of variance (ANOVA) was used (α =0.05).Results:The linear,volumetric,and geometric deviations were-0.03 ± 0.48 mm,-5.4 ± 2.8%,and 0.117 ± 0.018 mm for NewTom VG 0.15 mm group;-0.45 ± 0.42 mm,-4.5 ± 3.4%,and 0.116 ± 0.014 mm for NewTom VG 0.30 mm group;and-0.93 ± 0.40 mm,-4.8 ± 5.1%,and 0.194 ± 0.117 mm for VATECH DCTPRO 0.30 mm group,respectively.There were statistically significant differences between groups in terms of linear measurement (P < 0.001),but no significant difference in terms of volumetric measurement (P =0.774).No statistically significant difference were found on geometric measurement between NewTom VG 0.15 mm and

  3. Registration-based Reconstruction of Four-dimensional Cone Beam Computed Tomography

    DEFF Research Database (Denmark)

    Christoffersen, Christian; Hansen, David Christoffer; Poulsen, Per Rugaard

    2013-01-01

    and a clinical dataset. The obtained reconstructions are compared to the state-of-the-art alternatives of total variation regularization and prior image constrained compressed sensing. Our studies show that the proposed method is the better overall “compromise” in the depiction of both moving and stationary...

  4. 4D image reconstruction for emission tomography

    Science.gov (United States)

    Reader, Andrew J.; Verhaeghe, Jeroen

    2014-11-01

    An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear parameter estimation for a set of spatiotemporal functions chosen to approximately represent the radiotracer distribution, the areas of so-called ‘fully 4D’ image reconstruction and ‘direct kinetic parameter estimation’ are unified within a common framework. Many choices of linear and non-linear parameterization of these functions are considered (including the important case where the parameters have direct biological meaning), along with a review of the algorithms which are able to estimate these often non-linear parameters from emission tomography data. The other crucial components to image reconstruction (the objective function, the system model and the raw data format) are also covered, but in less detail due to the relatively straightforward extension from their corresponding components in conventional 3D image reconstruction. The key unifying concept is that maximum likelihood or maximum a posteriori (MAP) estimation of either linear or non-linear model parameters can be achieved in image space after carrying out a conventional expectation maximization (EM) update of the dynamic image series, using a Kullback-Leibler distance metric (comparing the modeled image values with the EM image values), to optimize the desired parameters. For MAP, an image-space penalty for regularization purposes is required. The benefits of 4D and direct reconstruction reported in the literature are reviewed, and furthermore demonstrated with simple simulation examples. It is clear that the future of reconstructing dynamic or functional emission tomography images, which often exhibit high levels of spatially correlated noise, should ideally exploit these 4D

  5. Three-Dimensional Reconstruction of the Bony Nasolacrimal Canal by Automated Segmentation of Computed Tomography Images.

    Directory of Open Access Journals (Sweden)

    Lucia Jañez-Garcia

    Full Text Available To apply a fully automated method to quantify the 3D structure of the bony nasolacrimal canal (NLC from CT scans whereby the size and main morphometric characteristics of the canal can be determined.Cross-sectional study.36 eyes of 18 healthy individuals.Using software designed to detect the boundaries of the NLC on CT images, 36 NLC reconstructions were prepared. These reconstructions were then used to calculate NLC volume. The NLC axis in each case was determined according to a polygonal model and to 2nd, 3rd and 4th degree polynomials. From these models, NLC sectional areas and length were determined. For each variable, descriptive statistics and normality tests (Kolmogorov-Smirnov and Shapiro-Wilk were established.Time for segmentation, NLC volume, axis, sectional areas and length.Mean processing time was around 30 seconds for segmenting each canal. All the variables generated were normally distributed. Measurements obtained using the four models polygonal, 2nd, 3rd and 4th degree polynomial, respectively, were: mean canal length 14.74, 14.3, 14.80, and 15.03 mm; mean sectional area 15.15, 11.77, 11.43, and 11.56 mm2; minimum sectional area 8.69, 7.62, 7.40, and 7.19 mm2; and mean depth of minimum sectional area (craniocaudal 7.85, 7.71, 8.19, and 8.08 mm.The method proposed automatically reconstructs the NLC on CT scans. Using these reconstructions, morphometric measurements can be calculated from NLC axis estimates based on polygonal and 2nd, 3rd and 4th polynomial models.

  6. Radiology series: Cone beam computed tomography: The fundamentals of image reconstruction and anatomy

    Directory of Open Access Journals (Sweden)

    Muralidhar Mupparapu

    2013-01-01

    Full Text Available This review is the first of series of CBCT. Multiplanar reconstructions for continuing education in three dimensional head and neck anatomy. This review gives the reader the needed anatomical references and clinical relevance for accurate interpretation of CBCT anatomy. The information is useful to all dental clinicians. All images are labeled and complete with legends. Only bone window settings are used for display of the CBCT images. The selected slices are displayed at a resolution of 300 micrometers.

  7. Penalized weighted least-squares approach for multienergy computed tomography image reconstruction via structure tensor total variation regularization.

    Science.gov (United States)

    Zeng, Dong; Gao, Yuanyuan; Huang, Jing; Bian, Zhaoying; Zhang, Hua; Lu, Lijun; Ma, Jianhua

    2016-10-01

    Multienergy computed tomography (MECT) allows identifying and differentiating different materials through simultaneous capture of multiple sets of energy-selective data belonging to specific energy windows. However, because sufficient photon counts are not available in each energy window compared with that in the whole energy window, the MECT images reconstructed by the analytical approach often suffer from poor signal-to-noise and strong streak artifacts. To address the particular challenge, this work presents a penalized weighted least-squares (PWLS) scheme by incorporating the new concept of structure tensor total variation (STV) regularization, which is henceforth referred to as 'PWLS-STV' for simplicity. Specifically, the STV regularization is derived by penalizing higher-order derivatives of the desired MECT images. Thus it could provide more robust measures of image variation, which can eliminate the patchy artifacts often observed in total variation (TV) regularization. Subsequently, an alternating optimization algorithm was adopted to minimize the objective function. Extensive experiments with a digital XCAT phantom and meat specimen clearly demonstrate that the present PWLS-STV algorithm can achieve more gains than the existing TV-based algorithms and the conventional filtered backpeojection (FBP) algorithm in terms of both quantitative and visual quality evaluations.

  8. Comparing five different iterative reconstruction algorithms for computed tomography in an ROC study.

    Science.gov (United States)

    Jensen, Kristin; Martinsen, Anne Catrine T; Tingberg, Anders; Aaløkken, Trond Mogens; Fosse, Erik

    2014-12-01

    The purpose of this study was to evaluate lesion conspicuity achieved with five different iterative reconstruction techniques from four CT vendors at three different dose levels. Comparisons were made of iterative algorithm and filtered back projection (FBP) among and within systems. An anthropomorphic liver phantom was examined with four CT systems, each from a different vendor. CTDIvol levels of 5 mGy, 10 mGy and 15 mGy were chosen. Images were reconstructed with FBP and the iterative algorithm on the system. Images were interpreted independently by four observers, and the areas under the ROC curve (AUCs) were calculated. Noise and contrast-to-noise ratios (CNR) were measured. One iterative algorithm increased AUC (0.79, 0.95, and 0.97) compared to FBP (0.70, 0.86, and 0.93) at all dose levels (p algorithm increased AUC from 0.78 with FBP to 0.84 (p = 0.007) at 5 mGy. Differences at 10 and 15 mGy were not significant (p-values: 0.084-0.883). Three algorithms showed no difference in AUC compared to FBP (p-values: 0.008-1.000). All of the algorithms decreased noise (10-71%) and improved CNR. Only two algorithms improved lesion detection, even though noise reduction was shown with all algorithms. Iterative reconstruction algorithms affected lesion detection differently at different dose levels. One iterative algorithm improved lesion detectability compared to filtered back projection. Three algorithms did not significantly improve lesion detectability. One algorithm improved lesion detectability at the lowest dose level.

  9. Bayesian image reconstruction: Application to emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, J.; Llacer, J.

    1989-02-01

    In this paper we propose a Maximum a Posteriori (MAP) method of image reconstruction in the Bayesian framework for the Poisson noise case. We use entropy to define the prior probability and likelihood to define the conditional probability. The method uses sharpness parameters which can be theoretically computed or adjusted, allowing us to obtain MAP reconstructions without the problem of the grey'' reconstructions associated with the pre Bayesian reconstructions. We have developed several ways to solve the reconstruction problem and propose a new iterative algorithm which is stable, maintains positivity and converges to feasible images faster than the Maximum Likelihood Estimate method. We have successfully applied the new method to the case of Emission Tomography, both with simulated and real data. 41 refs., 4 figs., 1 tab.

  10. Comparing five different iterative reconstruction algorithms for computed tomography in an ROC study

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Kristin; Martinsen, Anne Catrine T. [Rikshospitalet, The Intervention Centre, Postboks 4950, Oslo (Norway); University of Oslo, lnstitute of Physics, Oslo (Norway); Tingberg, Anders [Lund University, Skaane University Hospital, Department of Medical Radiation Physics, Malmoe (Sweden); Aaloekken, Trond Mogens [Rikshospitalet, Department of Radiology and Nuclear Medicine, Postboks 4950, Oslo (Norway); Fosse, Erik [Rikshospitalet, The Intervention Centre, Postboks 4950, Oslo (Norway); University of Oslo, lnstitute of Clinical Medicine, Oslo (Norway)

    2014-12-15

    The purpose of this study was to evaluate lesion conspicuity achieved with five different iterative reconstruction techniques from four CT vendors at three different dose levels. Comparisons were made of iterative algorithm and filtered back projection (FBP) among and within systems. An anthropomorphic liver phantom was examined with four CT systems, each from a different vendor. CTDI{sub vol} levels of 5 mGy, 10 mGy and 15 mGy were chosen. Images were reconstructed with FBP and the iterative algorithm on the system. Images were interpreted independently by four observers, and the areas under the ROC curve (AUCs) were calculated. Noise and contrast-to-noise ratios (CNR) were measured. One iterative algorithm increased AUC (0.79, 0.95, and 0.97) compared to FBP (0.70, 0.86, and 0.93) at all dose levels (p < 0.001 and p = 0.047). Another algorithm increased AUC from 0.78 with FBP to 0.84 (p = 0.007) at 5 mGy. Differences at 10 and 15 mGy were not significant (p-values: 0.084-0.883). Three algorithms showed no difference in AUC compared to FBP (p-values: 0.008-1.000). All of the algorithms decreased noise (10-71 %) and improved CNR. Only two algorithms improved lesion detection, even though noise reduction was shown with all algorithms. (orig.)

  11. Common-mask guided image reconstruction (c-MGIR) for enhanced 4D cone-beam computed tomography

    Science.gov (United States)

    Park, Justin C.; Zhang, Hao; Chen, Yunmei; Fan, Qiyong; Li, Jonathan G.; Liu, Chihray; Lu, Bo

    2015-12-01

    Compared to 3D cone beam computed tomography (3D CBCT), the image quality of commercially available four-dimensional (4D) CBCT is severely impaired due to the insufficient amount of projection data available for each phase. Since the traditional Feldkamp-Davis-Kress (FDK)-based algorithm is infeasible for reconstructing high quality 4D CBCT images with limited projections, investigators had developed several compress-sensing (CS) based algorithms to improve image quality. The aim of this study is to develop a novel algorithm which can provide better image quality than the FDK and other CS based algorithms with limited projections. We named this algorithm ‘the common mask guided image reconstruction’ (c-MGIR). In c-MGIR, the unknown CBCT volume is mathematically modeled as a combination of phase-specific motion vectors and phase-independent static vectors. The common-mask matrix, which is the key concept behind the c-MGIR algorithm, separates the common static part across all phase images from the possible moving part in each phase image. The moving part and the static part of the volumes were then alternatively updated by solving two sub-minimization problems iteratively. As the novel mathematical transformation allows the static volume and moving volumes to be updated (during each iteration) with global projections and ‘well’ solved static volume respectively, the algorithm was able to reduce the noise and under-sampling artifact (an issue faced by other algorithms) to the maximum extent. To evaluate the performance of our proposed c-MGIR, we utilized imaging data from both numerical phantoms and a lung cancer patient. The qualities of the images reconstructed with c-MGIR were compared with (1) standard FDK algorithm, (2) conventional total variation (CTV) based algorithm, (3) prior image constrained compressed sensing (PICCS) algorithm, and (4) motion-map constrained image reconstruction (MCIR) algorithm, respectively. To improve the efficiency of the

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  13. The dental cavities of equine cheek teeth: three-dimensional reconstructions based on high resolution micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Kopke Susan

    2012-09-01

    Full Text Available Abstract Background Recent studies reported on the very complex morphology of the pulp system in equine cheek teeth. The continuous production of secondary dentine leads to distinct age-related changes of the endodontic cavity. Detailed anatomical knowledge of the dental cavities in all ages is required to explain the aetiopathology of typical equine endodontic diseases. Furthermore, data on mandibular and maxillary pulp systems is in high demand to provide a basis for the development of endodontic therapies. However, until now examination of the pulp cavity has been based on either sectioned teeth or clinical computed tomography. More precise results were expected by using micro-computed tomography with a resolution of about 0.1 mm and three-dimensional reconstructions based on previous greyscale analyses and histological verification. The aim of the present study was to describe the physiological configurations of the pulp system within a wide spectrum of tooth ages. Results Maxillary teeth: All morphological constituents of the endodontic cavity were present in teeth between 4 and 16 years: Triadan 06s displayed six pulp horns and five root canals, Triadan 07-10s five pulp horns and four root canals and Triadan 11s seven pulp horns and four to six root canals. A common pulp chamber was most frequent in teeth ≤5 years, but was found even in a tooth of 9 years. A large variety of pulp configurations was observed within 2.5 and 16 years post eruption, but most commonly a separation into mesial and distal pulp compartments was seen. Maxillary cheek teeth showed up to four separate pulp compartments but the frequency of two, three and four pulp compartments was not related to tooth age (P > 0.05. In Triadan 06s, pulp horn 6 was always connected to pulp horns 1 and 3 and root canal I. In Triadan 11s, pulp horns 7 and 8 were present in variable constitutions. Mandibular teeth: A common pulp chamber was present in teeth up to 15 years, but most

  14. The dental cavities of equine cheek teeth: three-dimensional reconstructions based on high resolution micro-computed tomography

    Science.gov (United States)

    2012-01-01

    Background Recent studies reported on the very complex morphology of the pulp system in equine cheek teeth. The continuous production of secondary dentine leads to distinct age-related changes of the endodontic cavity. Detailed anatomical knowledge of the dental cavities in all ages is required to explain the aetiopathology of typical equine endodontic diseases. Furthermore, data on mandibular and maxillary pulp systems is in high demand to provide a basis for the development of endodontic therapies. However, until now examination of the pulp cavity has been based on either sectioned teeth or clinical computed tomography. More precise results were expected by using micro-computed tomography with a resolution of about 0.1 mm and three-dimensional reconstructions based on previous greyscale analyses and histological verification. The aim of the present study was to describe the physiological configurations of the pulp system within a wide spectrum of tooth ages. Results Maxillary teeth: All morphological constituents of the endodontic cavity were present in teeth between 4 and 16 years: Triadan 06s displayed six pulp horns and five root canals, Triadan 07-10s five pulp horns and four root canals and Triadan 11s seven pulp horns and four to six root canals. A common pulp chamber was most frequent in teeth ≤5 years, but was found even in a tooth of 9 years. A large variety of pulp configurations was observed within 2.5 and 16 years post eruption, but most commonly a separation into mesial and distal pulp compartments was seen. Maxillary cheek teeth showed up to four separate pulp compartments but the frequency of two, three and four pulp compartments was not related to tooth age (P > 0.05). In Triadan 06s, pulp horn 6 was always connected to pulp horns 1 and 3 and root canal I. In Triadan 11s, pulp horns 7 and 8 were present in variable constitutions. Mandibular teeth: A common pulp chamber was present in teeth up to 15 years, but most commonly seen in teeth ≤5

  15. Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization

    Energy Technology Data Exchange (ETDEWEB)

    Mory, Cyril, E-mail: cyril.mory@philips.com [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, F-69621 Villeurbanne Cedex (France); Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes (France); Auvray, Vincent; Zhang, Bo [Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes (France); Grass, Michael; Schäfer, Dirk [Philips Research, Röntgenstrasse 24–26, D-22335 Hamburg (Germany); Chen, S. James; Carroll, John D. [Department of Medicine, Division of Cardiology, University of Colorado Denver, 12605 East 16th Avenue, Aurora, Colorado 80045 (United States); Rit, Simon [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1 (France); Centre Léon Bérard, 28 rue Laënnec, F-69373 Lyon (France); Peyrin, Françoise [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, F-69621 Villeurbanne Cedex (France); X-ray Imaging Group, European Synchrotron, Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Douek, Philippe; Boussel, Loïc [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1 (France); Hospices Civils de Lyon, 28 Avenue du Doyen Jean Lépine, 69500 Bron (France)

    2014-02-15

    Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method, which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection.

  16. Computed tomography-guided implant surgery for dental rehabilitation in mandible reconstructed with a fibular free flap: description of the technique.

    Science.gov (United States)

    De Riu, Giacomo; Meloni, Silvio Mario; Pisano, Milena; Massarelli, Olindo; Tullio, Antonio

    2012-01-01

    The fibular free flap, with or without a cutaneous component, is the gold standard for reconstructing mandibular defects. Dental prosthetic rehabilitation is possible this way, even if the prosthesis-based implant is still a challenge because of the many anatomical and prosthetic problems. We think that complications can be overcome or reduced by adopting the new methods of computed tomography (CT)-assisted implant surgery (NobelGuide, Nobel Biocare AB, Goteborg, Sweden). Here we describe the possibility of using CT-guided implant surgery with a flapless approach and immediate loading in mandibles reconstructed with fibular free flaps.

  17. Numerical reconstruction of pulsatile blood flow from 4D computer tomography angiography data

    CERN Document Server

    Lovas, Attila; Csobo, Elek; Szilágyi, Brigitta; Sótonyi, Péter

    2015-01-01

    We present a novel numerical algorithm developed to reconstuct pulsatile blood flow from ECG-gated CT angiography data. A block-based optimization method was constructed to solve the inverse problem corresponding to the Riccati-type ordinary differential equation that can be deduced from conservation principles and Hooke's law. Local flow rate for 5 patients was computed in 10cm long aorta segments that are located 1cm below the heart. The wave form of the local flow rate curves seems to be realistic. Our approach is suitable for estimating characteristics of pulsatile blood flow in aorta based on ECG gated CT scan thereby contributing to more accurate description of several cardiovascular lesions.

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  5. Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction

    Directory of Open Access Journals (Sweden)

    Naghibi

    2015-12-01

    Full Text Available Background Chronic otitis media (COM can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT scan plays an important role in optimizing surgical planning. Objectives This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. Patients and Methods Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000. Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. Results Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001, decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001, and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001. No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125, and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172. In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. Conclusion Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients.

  6. Computed laminography and reconstruction algorithm

    Institute of Scientific and Technical Information of China (English)

    QUE Jie-Min; YU Zhong-Qiang; YAN Yong-Lian; CAO Da-Quan; ZHAO Wei; TANG Xiao; SUN Cui-Li; WANG Yan-Fang; WEI Cun-Feng; SHI Rong-Jian; WEI Long

    2012-01-01

    Computed laminography (CL) is an alternative to computed tomography if large objects are to be inspected with high resolution.This is especially true for planar objects.In this paper,we set up a new scanning geometry for CL,and study the algebraic reconstruction technique (ART) for CL imaging.We compare the results of ART with variant weighted functions by computer simulation with a digital phantom.It proves that ART algorithm is a good choice for the CL system.

  7. Implementation on GPU-based acceleration of the m-line reconstruction algorithm for circle-plus-line trajectory computed tomography

    Science.gov (United States)

    Li, Zengguang; Xi, Xiaoqi; Han, Yu; Yan, Bin; Li, Lei

    2016-10-01

    The circle-plus-line trajectory satisfies the exact reconstruction data sufficiency condition, which can be applied in C-arm X-ray Computed Tomography (CT) system to increase reconstruction image quality in a large cone angle. The m-line reconstruction algorithm is adopted for this trajectory. The selection of the direction of m-lines is quite flexible and the m-line algorithm needs less data for accurate reconstruction compared with FDK-type algorithms. However, the computation complexity of the algorithm is very large to obtain efficient serial processing calculations. The reconstruction speed has become an important issue which limits its practical applications. Therefore, the acceleration of the algorithm has great meanings. Compared with other hardware accelerations, the graphics processing unit (GPU) has become the mainstream in the CT image reconstruction. GPU acceleration has achieved a better acceleration effect in FDK-type algorithms. But the implementation of the m-line algorithm's acceleration for the circle-plus-line trajectory is different from the FDK algorithm. The parallelism of the circular-plus-line algorithm needs to be analyzed to design the appropriate acceleration strategy. The implementation can be divided into the following steps. First, selecting m-lines to cover the entire object to be rebuilt; second, calculating differentiated back projection of the point on the m-lines; third, performing Hilbert filtering along the m-line direction; finally, the m-line reconstruction results need to be three-dimensional-resembled and then obtain the Cartesian coordinate reconstruction results. In this paper, we design the reasonable GPU acceleration strategies for each step to improve the reconstruction speed as much as possible. The main contribution is to design an appropriate acceleration strategy for the circle-plus-line trajectory m-line reconstruction algorithm. Sheep-Logan phantom is used to simulate the experiment on a single K20 GPU. The

  8. Computed Tomography of Transverse Phase Space

    Energy Technology Data Exchange (ETDEWEB)

    Watts, A. [Fermilab; Johnstone, C. [Fermilab; Johnstone, J. [Fermilab

    2016-09-19

    Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ... stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and skull or ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ... the best imaging modality for sinusitis. Tell your doctor if there’s a possibility you are pregnant and ...

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... for a recovery period and will be given instructions on any limitations in activity for the day. ... Images related to Children's (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) CT (Computed Tomography) Sponsored ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography ( ... more commonly known as a CT or CAT scan, is a diagnostic medical test that, like traditional ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless ... table. Other imaging methods such as ultrasound or magnetic resonance (MR) imaging can provide pictures of certain areas ...

  18. Brain perfusion imaging using a Reconstruction-of-Difference (RoD) approach for cone-beam computed tomography

    Science.gov (United States)

    Mow, M.; Zbijewski, W.; Sisniega, A.; Xu, J.; Dang, H.; Stayman, J. W.; Wang, X.; Foos, D. H.; Koliatsos, V.; Aygun, N.; Siewerdsen, J. H.

    2017-03-01

    Purpose: To improve the timely detection and treatment of intracranial hemorrhage or ischemic stroke, recent efforts include the development of cone-beam CT (CBCT) systems for perfusion imaging and new approaches to estimate perfusion parameters despite slow rotation speeds compared to multi-detector CT (MDCT) systems. This work describes development of a brain perfusion CBCT method using a reconstruction of difference (RoD) approach to enable perfusion imaging on a newly developed CBCT head scanner prototype. Methods: A new reconstruction approach using RoD with a penalized-likelihood framework was developed to image the temporal dynamics of vascular enhancement. A digital perfusion simulation was developed to give a realistic representation of brain anatomy, artifacts, noise, scanner characteristics, and hemo-dynamic properties. This simulation includes a digital brain phantom, time-attenuation curves and noise parameters, a novel forward projection method for improved computational efficiency, and perfusion parameter calculation. Results: Our results show the feasibility of estimating perfusion parameters from a set of images reconstructed from slow scans, sparse data sets, and arc length scans as short as 60 degrees. The RoD framework significantly reduces noise and time-varying artifacts from inconsistent projections. Proper regularization and the use of overlapping reconstructed arcs can potentially further decrease bias and increase temporal resolution, respectively. Conclusions: A digital brain perfusion simulation with RoD imaging approach has been developed and supports the feasibility of using a CBCT head scanner for perfusion imaging. Future work will include testing with data acquired using a 3D-printed perfusion phantom currently and translation to preclinical and clinical studies.

  19. Proton computed tomography

    Science.gov (United States)

    Bucciantonio, Martina; Sauli, Fabio

    2015-05-01

    Proton computed tomography (pCT) is a diagnostic method capable of in situ imaging the three-dimensional density distribution in a patient before irradiation with charged particle beams. Proposed long time ago, this technology has been developed by several groups, and may become an essential tool for advanced quality assessment in hadrontherapy. We describe the basic principles of the method, its performance and limitations as well as provide a summary of experimental systems and of results achieved.

  20. The use of 3D computed tomography reconstruction in medico-legal testimony regarding injuries in living victims - Risks and benefits.

    Science.gov (United States)

    Borowska-Solonynko, Aleksandra; Solonynko, Bohdan

    2015-02-01

    Forensic pathologists are often called upon to determine the mechanism and severity of injuries in living individuals. Such expert testimony is often based solely on hand-written clinical notes. The victims' injuries may also be visualized via three-dimensional (3D) reconstruction of computed tomography (CT) images. This method has certain benefits but is not free from limitations. This paper presents two case reports. The first case is that of a female who was brought to the hospital with a knife thrust into her body. The prosecutor's questions focused on the wound channel. The information obtained from the patient's medical records was very general with many contradictory statements. A re-evaluation of the available CT scan data and a subsequent 3D reconstruction helped determine the exact course of the wound channel. The other case was that of a young male, hospitalized based on CT evidence of bilateral rib fractions, who claimed to have been assaulted by police officers. Court expert witnesses were already in possession of a 3D reconstruction showing symmetrical fractures of the patient's lower ribs with bone fragment displacement. An expert witness in radiology definitively excluded the presence of any actual fractures, and explained their apparent visibility in the three-dimensionally reconstructed image as a motion artifact. These two cases suggest that a professionally conducted 3D CT reconstruction is a very useful tool in providing expert testimony on injuries in living victims. However, the deceptive simplicity of conducting such a reconstruction may encourage inexperienced individuals to undertake it, and thus lead to erroneous conclusions. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  1. Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

    Science.gov (United States)

    Czabaj, M. W.; Riccio, M. L.; Whitacre, W. W.

    2014-01-01

    A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

  2. Parallel Computing for the Computed-Tomography Imaging Spectrometer

    Science.gov (United States)

    Lee, Seungwon

    2008-01-01

    This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

  3. Computed tomography of cryogenic cells

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-08-30

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions.

  4. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  5. Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique. Comparison with angiographic results

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yuichi; Matsumoto, Naoya; Kato, Masahiko [Nihon Univ., Tokyo (Japan). Surugadai Hospital] [and others

    2003-04-01

    The present study was designed to investigate the accuracy of multislice spiral computed tomography (MSCT) in detecting coronary artery disease, compared with coronary angiography (CAG), using a new retrospectively ECG-gated reconstruction method that reduced cardiac motion artifact. The study group comprised 54 consecutive patients undergoing MSCT and CAG. MSCT was performed using a SOMATOM Volume Zoom (4-detector-row, Siemens, Germany) with slice thickness 1.0 mm, pitch 1.5 (table feed: 1.5 mm per rotation) and gantry rotation time 500 ms. Metoprolol (20-60 mg) was administered orally prior to MSCT imaging. ECG-gated image reconstruction was performed with the reconstruction window (250 ms) positioned immediately before atrial contraction in order to reduce the cardiac motion artifact caused by the abrupt diastolic ventricular movement occurring during the rapid filling and atrial contraction periods. Following inspection of the volume rendering images, multiplanar reconstruction images and axial images of the left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCx) and right coronary artery (RCA) were obtained and evaluated for luminal narrowing. The results were compared with those obtained by CAG. Of 216 coronary arteries, 206 (95.4%) were assessable; 10 arteries were excluded from the analysis because of severe calcification (n=4), stents (n=3) or insufficient contrast enhancement (n=3). The sensitivity to detect coronary stenoses {>=}50% was 93.5% and the specificity to define luminal narrowing <50% was 97.2%. The positive predictive value and the negative predictive value were 93.5% and 97.2%, respectively. The sensitivity was still satisfactory (80.6%) even when non-assessable arteries were included in the analysis. The new retrospectively ECG-gated reconstruction method for MSCT has excellent diagnostic accuracy in detecting significant coronary artery stenoses. (author)

  6. Computer processing of tomography data

    OpenAIRE

    Konečný, Jan

    2011-01-01

    Computer processing of tomography data Tomographs are one of the most important diagnostic devices, which are used in every hospital nowadays; they have already been so for a considerable period of time. The different types of tomographs and the processing of tomographic data and imaging of these data are the subject of this thesis. I have described the four most common types of tomography: X-ray Computed Tomography, Magnetic Resonance Imaging, Positron Emission Tomography and Single Photon E...

  7. Quantitative and qualitative comparison of standard-dose and low-dose pediatric head computed tomography: a retrospective study assessing the effect of adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Kilic, Koray; Erbas, Gonca; Guryildirim, Melike; Konus, Oznur Leman; Arac, Mehmet; Ilgit, Erhan; Isik, Sedat

    2013-01-01

    Our aim was to assess the effect of adaptive statistical iterative reconstruction (ASIR) on pediatric head computed tomography (CT) examinations. We retrospectively reviewed 305 pediatric head CT examinations. The study population consisted of standard dose (STD, n = 152) examinations reconstructed with filtered back projection and low dose (LD, n = 153) examinations reconstructed with 30% (LD30) and 0% (LD0) ASIR. We compared groups by means of radiation dose, noise measures, and visual grading. Student t test, 1-way analysis of variance test, and Mann-Whitney U test were used for statistical analysis. The dose in the LD30 group was significantly lower (29%) than that in the STD group (P < 0.001). The noise in the white matter (P < 0.001), SNR (P < 0.001), and subjective image noise (P = 0.044) was significantly better in the STD group than those in the LD30 group. There was no significant difference between LD30 and STD groups in the sharpness (P = 0.141), diagnostic acceptability (P = 0.079), and artifacts (P = 0.750) and contrast-to-noise ratio (P = 0.718). In conclusion, we found that a blend of 30% ASIR in a 16-slice multidetector CT produces diagnostically acceptable pediatric head CT examinations with a 29% less dose.

  8. Abdominal perfusion computed tomography.

    Science.gov (United States)

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-02-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

  9. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    Clinical trials for the treatment of cystic fibrosis (CF) lung disease are important to test and optimize new therapeutic interventions. To evaluate the effect of these interventions, sensitive and accurate outcome measures are needed. The most commonly used endpoints are spirometric variables...... are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  10. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  11. Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs.

    Science.gov (United States)

    Brzobohatá, Hana; Prokop, Josef; Horák, Martin; Jancárek, Alexandr; Velemínská, Jana

    2012-09-01

    The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used.

  12. Future of cardiac computed tomography

    Institute of Scientific and Technical Information of China (English)

    Carlo N De Cecco; U Joseph Schoepf

    2015-01-01

    Coronary computed tomography angiography(CCTA)has become an integral tool in the noninvasive diagnostic workup of patients with suspected coronary artery disease in both elective and emergency settings. Today, it represents a mature technique providing accurate, non-invasive morphological assessment of the coronary arteries and atherosclerotic plaque burden. Iterative reconstruction algorithms, low kV imaging, and single-heart beat acquisitions hold promise to further reduce dose requirements and improve the safety and robustness of the technique in several circumstances including imaging of heavily calcified vessels, patients with morbid obesity or irregular heart rates, and assessment in the emergency setting. However, it has become clear over recent years that cardiac radiologists need to take further steps towards the development and integration of functional imaging with morphological CCTA assessment to truly provide a comprehensive evaluation of the heart. Computed tomography myocardial perfusion imaging, including both dynamic and static dual-energy approaches, has demonstrated the ability to directly assess and quantify myocardial ischemia with simultaneous CCTA acquisition with a reasonable contrast medium volume and radiation dose delivered to the patient. In order to promote CCTA in the clinical and research environments, radiologists should prepare to embrace the change from morphological to functional imaging, furnishing all the necessary resources and information to referring clinicians.

  13. Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?

    Energy Technology Data Exchange (ETDEWEB)

    Juergens, Kai Uwe; Maintz, David; Heimes, Britta; Fallenberg, Eva Maria; Heindel, Walter; Fischbach, Roman [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Grude, Matthias [University of Muenster, Department of Cardiology and Angiology, Muenster (Germany); Boese, Jan M. [Siemens Medical Solutions, Forchheim (Germany)

    2005-01-01

    A multi-segment cardiac image reconstruction algorithm in multi-detector row computed tomography (MDCT) was evaluated regarding temporal resolution and determination of left ventricular (LV) volumes and global LV function. MDCT and cine magnetic resonance (CMR) imaging were performed in 12 patients with known or suspected coronary artery disease. Patients gave informed written consent for the MDCT and the CMR exam. MDCT data were reconstructed using the standard adaptive cardiac volume (ACV) algorithm as well as a multi-segment algorithm utilizing data from three, five and seven rotations. LV end-diastolic (LV-EDV) and end-systolic volumes and ejection fraction (LV-EF) were determined from short-axis image reformations and compared to CMR data. Mean temporal resolution achieved was 192{+-}24 ms using the ACV algorithm and improved significantly utilizing the three, five and seven data segments to 139{+-}12, 113{+-}13 and 96{+-}11 ms (P<0.001 for each). Mean LV-EDV was without significant differences using the ACV algorithm, the multi-segment approach and CMR imaging. Despite improved temporal resolution with multi-segment image reconstruction, end-systolic volumes were less accurately measured (mean differences 3.9{+-}11.8 ml to 8.1{+-}13.9 ml), resulting in a consistent underestimation of LV-EF by 2.3-5.4% in comparison to CMR imaging (Bland-Altman analysis). Multi-segment image reconstruction improves temporal resolution compared to the standard ACV algorithm, but this does not result in a benefit for determination of LV volume and function. (orig.)

  14. Computed tomography angiographic study of internal mammary perforators and their use as recipient vessels for free tissue transfer in breast reconstruction

    Directory of Open Access Journals (Sweden)

    Aditya V Kanoi

    2017-01-01

    Full Text Available Context: The internal mammary artery perforator vessels (IMPV as a recipient in free flap breast reconstruction offer advantages over the more commonly used thoracodorsal vessels and the internal mammary vessels (IMV. Aims: This study was designed to assess the anatomical consistency of the IMPV and the suitability of these vessels for use as recipients in free flap breast reconstruction. Patients and Methods: Data from ten randomly selected female patients who did not have any chest wall or breast pathology but had undergone a computed tomography angiography (CTA for unrelated diagnostic reasons from April 2013 to October 2013 were analysed. Retrospective data of seven patients who had undergone mastectomy for breast cancer and had been primarily reconstructed with a deep inferior epigastric artery perforator free flap transfer using the IMPV as recipient vessels were studied. Results: The CTA findings showed that the internal mammary perforator was consistently present in all cases bilaterally. In all cases, the dominant perforator arose from the upper four intercostal spaces (ICS with the majority (55% arising from the 2nd ICS. The mean distance of the perforators from the sternal border at the level of pectoralis muscle surface on the right side was 1.86 cm (range: 0.9–2.5 cm with a mode value of 1.9 cm. On the left side, a mean of 1.77 cm (range: 1.5–2.1 cm and a mode value of 1.7 cm were observed. Mean perforator artery diameters on the right and left sides were 2.2 mm and 2.4 mm, respectively. Conclusions: Though the internal mammary perforators are anatomically consistent, their use as recipients in free tissue transfer for breast reconstruction eventually rests on multiple variables.

  15. A Freeware Path to Neutron Computed Tomography

    Science.gov (United States)

    Schillinger, Burkhard; Craft, Aaron E.

    Neutron computed tomography has become a routine method at many neutron sources due to the availability of digital detection systems, powerful computers and advanced software. The commercial packages Octopus by Inside Matters and VGStudio by Volume Graphics have been established as a quasi-standard for high-end computed tomography. However, these packages require a stiff investment and are available to the users only on-site at the imaging facility to do their data processing. There is a demand from users to have image processing software at home to do further data processing; in addition, neutron computed tomography is now being introduced even at smaller and older reactors. Operators need to show a first working tomography setup before they can obtain a budget to build an advanced tomography system. Several packages are available on the web for free; however, these have been developed for X-rays or synchrotron radiation and are not immediately useable for neutron computed tomography. Three reconstruction packages and three 3D-viewers have been identified and used even for Gigabyte datasets. This paper is not a scientific publication in the classic sense, but is intended as a review to provide searchable help to make the described packages usable for the tomography community. It presents the necessary additional preprocessing in ImageJ, some workarounds for bugs in the software, and undocumented or badly documented parameters that need to be adapted for neutron computed tomography. The result is a slightly complicated, but surprisingly high-quality path to neutron computed tomography images in 3D, but not a replacement for the even more powerful commercial software mentioned above.

  16. Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis

    Institute of Scientific and Technical Information of China (English)

    Liang Zhu

    2014-01-01

    Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography (DSCT) with sinogram affirmed iterative reconstruction (SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans (protocol 1) [tube voltage of 120 kVp/pitch of 0.9/filtered back-projection (FBP) reconstruction] followed by high-pitch non-enhanced CT scans (protocol 2) (100 kVp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio (SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1 (1.4±0.1 seconds vs. 7.6±0.6 seconds, P Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.

  17. Optimization-based image reconstruction in x-ray computed tomography by sparsity exploitation of local continuity and nonlocal spatial self-similarity

    Science.gov (United States)

    Han-Ming, Zhang; Lin-Yuan, Wang; Lei, Li; Bin, Yan; Ai-Long, Cai; Guo-En, Hu

    2016-07-01

    The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography (CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts. To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated. The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation. Project supported by the National Natural Science Foundation of China (Grant No. 61372172).

  18. Optimum CT reconstruction parameters for vascular and hepatocellular carcinoma models in a liver phantom with multi-level dynamic computed tomography with 64 detector rows: a basic study.

    Science.gov (United States)

    Murotani, Kazuhiro; Kazuhiro, Murotani; Kawai, Nobuyuki; Sato, Morio; Minamiguchi, Hiroki; Nakai, Motoki; Sonomura, Tetsuo; Hosokawa, Seiki; Nishioku, Tadayoshi

    2013-07-01

    We quantified to clarify the optimum factors for CT image reconstruction of an enhanced hepatocellular carcinoma (HCC) model in a liver phantom obtained by multi-level dynamic computed tomography (M-LDCT) with 64 detector rows. After M-LDCT scanning of a water phantom and an enhanced HCC model, we compared the standard deviation (SD, 1 ± SD), noise power spectrum (NPS) values, contrast-noise ratios (CNR), and the M-LDCT image among the reconstruction parameters, including the convolution kernel (FC11, FC13, and FC15), post-processing quantum filters (2D-Q00, 2D-Q01, and 2D-Q02) and slice thicknesses/slice intervals. The SD and NPS values were lowest with FC11 and 2D-Q02. The CNR values were highest with 2D-Q02. The M-LDCT image quality was highest with FC11 and 2D-Q02, and with slice thicknesses/slice intervals of 0.5 mm/0.5 mm and 0.5 mm/0.25 mm. The optimum factors were the FC11 convolution kernel, 2D-Q02 quantum filter, and 0.5 mm slice thickness/0.5 mm slice interval or less.

  19. Quantification and Reconstruction in Photoacoustic Tomography

    Science.gov (United States)

    Guo, Zijian

    Optical absorption is closely associated with many physiological important parameters, such as the concentration and oxygen saturation of hemoglobin. Conventionally, accurate quantification in PAT requires knowledge of the optical fluence attenuation, acoustic pressure attenuation, and detection bandwidth. We circumvent this requirement by quantifying the optical absorption coefficients from the acoustic spectra of PA signals acquired at multiple optical wavelengths. We demonstrate the method using the optical-resolution photoacoustic microscopy (OR-PAM) and the acoustical-resolution photoacoustic microscopy (AR-PAM) in the optical ballistic regime and in the optical diffusive regime, respectively. The data acquisition speed in photoacoustic computed tomography (PACT) is limited by the laser repetition rate and the number of parallel ultrasound detecting channels. Reconstructing an image with fewer measurements can effectively accelerate the data acquisition and reduce the system cost. We adapted Compressed Sensing (CS) for the reconstruction in PACT. CS-based PACT was implemented as a non-linear conjugate gradient descent algorithm and tested with both phantom and in vivo experiments. Speckles have been considered ubiquitous in all scattering-based coherent imaging technologies. As a coherent imaging modality based on optical absorption, photoacoustic (PA) tomography (PAT) is generally devoid of speckles. PAT suppresses speckles by building up prominent boundary signals, via a mechanism similar to that of specular reflection. When imaging smooth boundary absorbing targets, the speckle visibility in PAT, which is defined as the ratio of the square root of the average power of speckles to that of boundaries, is inversely proportional to the square root of the absorber density. If the surfaces of the absorbing targets have uncorrelated height fluctuations, however, the boundary features may become fully developed speckles. The findings were validated by simulations

  20. Metrizamide computed tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, T.; Tamakawa, Y.; Arii, H. (Akita Univ. (Japan). Faculty of Medicine); Takahashi, M.; Hirota, K.

    1981-11-01

    Serial computed tomography of the cervical cord was performed following metrizamide myelography in five cases of clinically suspected syringomyelia. The syrinx filled with refluxed metrizamide was demonstrated in all of the cases. The reflux of metrizamide into the syrinx was most marked several hours following intrathecal injection of metrizamide. Computed tomography combined with metrizamide myelography is essential in the diagnosis of communicating syringomyelia.

  1. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    Energy Technology Data Exchange (ETDEWEB)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong (Second Hospital Affiliated to the Medical College of Xi' an Jiaotong Univ., Xi' an Shaanxi (China))

    2009-08-15

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8+-2.1 mm and 7.1+-3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  2. Image reconstruction for robot assisted ultrasound tomography

    Science.gov (United States)

    Aalamifar, Fereshteh; Zhang, Haichong K.; Rahmim, Arman; Boctor, Emad M.

    2016-04-01

    An investigation of several image reconstruction methods for robot-assisted ultrasound (US) tomography setup is presented. In the robot-assisted setup, an expert moves the US probe to the location of interest, and a robotic arm automatically aligns another US probe with it. The two aligned probes can then transmit and receive US signals which are subsequently used for tomographic reconstruction. This study focuses on reconstruction of the speed of sound. In various simulation evaluations as well as in an experiment with a millimeter-range inaccuracy, we demonstrate that the limited data provided by two probes can be used to reconstruct pixel-wise images differentiating between media with different speeds of sound. Combining the results of this investigation with the developed robot-assisted US tomography setup, we envision feasibility of this setup for tomographic imaging in applications beyond breast imaging, with potentially significant efficacy in cancer diagnosis.

  3. Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Young Jin; Choi, Young Hun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Ha, Seongmin [New York-Presbyterian Hospital and the Weill Cornell Medical College, Dalio Institute of Cardiovascular Imaging, New York, NY (United States)

    2016-03-15

    CT of pediatric phantoms can provide useful guidance to the optimization of knowledge-based iterative reconstruction CT. To compare radiation dose and image quality of CT images obtained at different radiation doses reconstructed with knowledge-based iterative reconstruction, hybrid iterative reconstruction and filtered back-projection. We scanned a 5-year anthropomorphic phantom at seven levels of radiation. We then reconstructed CT data with knowledge-based iterative reconstruction (iterative model reconstruction [IMR] levels 1, 2 and 3; Philips Healthcare, Andover, MA), hybrid iterative reconstruction (iDose{sup 4}, levels 3 and 7; Philips Healthcare, Andover, MA) and filtered back-projection. The noise, signal-to-noise ratio and contrast-to-noise ratio were calculated. We evaluated low-contrast resolutions and detectability by low-contrast targets and subjective and objective spatial resolutions by the line pairs and wire. With radiation at 100 peak kVp and 100 mAs (3.64 mSv), the relative doses ranged from 5% (0.19 mSv) to 150% (5.46 mSv). Lower noise and higher signal-to-noise, contrast-to-noise and objective spatial resolution were generally achieved in ascending order of filtered back-projection, iDose{sup 4} levels 3 and 7, and IMR levels 1, 2 and 3, at all radiation dose levels. Compared with filtered back-projection at 100% dose, similar noise levels were obtained on IMR level 2 images at 24% dose and iDose{sup 4} level 3 images at 50% dose, respectively. Regarding low-contrast resolution, low-contrast detectability and objective spatial resolution, IMR level 2 images at 24% dose showed comparable image quality with filtered back-projection at 100% dose. Subjective spatial resolution was not greatly affected by reconstruction algorithm. Reduced-dose IMR obtained at 0.92 mSv (24%) showed similar image quality to routine-dose filtered back-projection obtained at 3.64 mSv (100%), and half-dose iDose{sup 4} obtained at 1.81 mSv. (orig.)

  4. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Xiaoming, E-mail: mmayzy2008@126.com; Li, Tao, E-mail: litaofeivip@163.com; Li, Xin, E-mail: lx0803@sina.com.cn; Zhou, Weihua, E-mail: wangxue0606@gmail.com

    2015-05-15

    Highlights: • High-resolution scan mode is appropriate for imaging coronary stent. • HD-detail reconstruction algorithm is stent-dedicated kernel. • The intrastent lumen visibility also depends on stent diameter and material. - Abstract: Objective: The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Materials and methods: Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. Results: The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0 ± 8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Conclusions: Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement.

  5. Task-driven tube current modulation and regularization design in computed tomography with penalized-likelihood reconstruction

    Science.gov (United States)

    Gang, G. J.; Siewerdsen, J. H.; Stayman, J. W.

    2016-03-01

    Purpose: This work applies task-driven optimization to design CT tube current modulation and directional regularization in penalized-likelihood (PL) reconstruction. The relative performance of modulation schemes commonly adopted for filtered-backprojection (FBP) reconstruction were also evaluated for PL in comparison. Methods: We adopt a task-driven imaging framework that utilizes a patient-specific anatomical model and information of the imaging task to optimize imaging performance in terms of detectability index (d'). This framework leverages a theoretical model based on implicit function theorem and Fourier approximations to predict local spatial resolution and noise characteristics of PL reconstruction as a function of the imaging parameters to be optimized. Tube current modulation was parameterized as a linear combination of Gaussian basis functions, and regularization was based on the design of (directional) pairwise penalty weights for the 8 in-plane neighboring voxels. Detectability was optimized using a covariance matrix adaptation evolutionary strategy algorithm. Task-driven designs were compared to conventional tube current modulation strategies for a Gaussian detection task in an abdomen phantom. Results: The task-driven design yielded the best performance, improving d' by ~20% over an unmodulated acquisition. Contrary to FBP, PL reconstruction using automatic exposure control and modulation based on minimum variance (in FBP) performed worse than the unmodulated case, decreasing d' by 16% and 9%, respectively. Conclusions: This work shows that conventional tube current modulation schemes suitable for FBP can be suboptimal for PL reconstruction. Thus, the proposed task-driven optimization provides additional opportunities for improved imaging performance and dose reduction beyond that achievable with conventional acquisition and reconstruction.

  6. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Precht, Helle; Leth, Peter Mygind; Thygesen, Jesper

    2014-01-01

    Introduction: Coronary atherosclerosis is a leading cause of mortality. New technological developments in computed tomography (CT), including dual energy, iterative reconstructions and high definition scanning, could significantly improve the non-invasive identification of atherosclerosis plaques...

  7. Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients

    Energy Technology Data Exchange (ETDEWEB)

    Pontana, Francois; Pagniez, Julien; Faivre, Jean-Baptiste; Remy, Jacques [Univ. Lille Nord de France, Department of Thoracic Imaging Hospital Calmette (EA 2694), Lille (France); Flohr, Thomas [Siemens HealthCare, Computed Tomography Division, Forchheim (Germany); Duhamel, Alain [Univ. Lille Nord de France, Department of Medical Statistics, Lille (France); Remy-Jardin, Martine [Univ. Lille Nord de France, Department of Thoracic Imaging Hospital Calmette (EA 2694), Lille (France); Hospital Calmette, Department of Thoracic Imaging, Lille cedex (France)

    2011-03-15

    To assess noise reduction achievable with an iterative reconstruction algorithm. 32 consecutive chest CT angiograms were reconstructed with regular filtered back projection (FBP) (Group 1) and an iterative reconstruction technique (IRIS) with 3 (Group 2a) and 5 (Group 2b) iterations. Objective image noise was significantly reduced in Group 2a and Group 2b compared with FBP (p < 0.0001). There was a significant reduction in the level of subjective image noise in Group 2a compared with Group 1 images (p < 0.003), further reinforced on Group 2b images (Group 2b vs Group 1; p < 0.0001) (Group 2b vs Group 2a; p = 0.0006). The overall image quality scores significantly improved on Group 2a images compared with Group 1 images (p = 0.0081) and on Group 2b images compared with Group 2a images (p < 0.0001). Comparative analysis of individual CT features of mild lung infiltration showed improved conspicuity of ground glass attenuation (p < 0.0001), ill-defined micronodules (p = 0.0351) and emphysematous lesions (p < 0.0001) on Group 2a images, further improved on Group 2b images for ground glass attenuation (p < 0.0001), and emphysematous lesions (p = 0.0087). Compared with regular FBP, iterative reconstructions enable significant reduction of image noise without loss of diagnostic information, thus having the potential to decrease radiation dose during chest CT examinations. (orig.)

  8. Quantitative study of undersampled recoverability for sparse images in computed tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Heide; Sidky, Emil Y.; Hansen, Per Christian

    2012-01-01

    Image reconstruction methods based on exploiting image sparsity, motivated by compressed sensing (CS), allow reconstruction from a significantly reduced number of projections in X-ray computed tomography (CT). However, CS provides neither theoretical guarantees of accurate CT reconstruction, nor...

  9. Preliminary clinical application of an adaptive iterative statistical reconstruction algorithm inhead and neck computed tomography angiography with low tube voltage and a low concentration of contrast medium

    Institute of Scientific and Technical Information of China (English)

    Shan Hu; Wenzhen Zhu; Daoyu Hu; XiaoYan Meng; Jinhua Zhang; Weijia Wan; Li Zhou

    2015-01-01

    Objective To evaluate the feasibility of using a low concentration of contrast medium (Visipaque 270 mgI/mL), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography angiography (CTA). Methods Forty patients (22 men and 18 women; average age 48.7 ± 14.25 years; average body mass index 23.9 ± 3.7 kg/m2) undergoing CTA for suspected vascular diseases were randomly assigned into two groups. Group A (n = 20) was administered 370 mgI/mL contrast medium, and group B (n = 20) was administered 270 mgI/mL contrast medium. Both groups were administered at a rate of 4.8 mL/s and an injection volume of 0.8 mL/kg. Images of group A were obtained with 120 kVp and filtered back projection (FBP) reconstruction, whereas images of group B were obtained with 80 kVp and 80% adaptive iterative statistical reconstruction algorithm (ASiR). The CT values and standard deviations of intracranial arteries and image noise on the corona radiata were measured to calculate the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). The beam-hardening artifacts (BHAs) around the skul base were calculated. Two readers evaluated the image quality with volume rendered images using scores from 1 to 5. The values between the two groups were statistical y compared. Results The mean CT value of the intracranial arteries in group B was significantly higher than that in group A (P < 0.001). The CNR and SNR values in group B were also statistical y higher than those in group A (P < 0.001). Image noise and BHAs were not significantly dif erent between the two groups. The image quality score of VR images of in group B was significantly higher than that in group A (P = 0.001). However, the quality scores of axial enhancement images in group B became significantly smal er than those in group A (P< 0.001). The CT dose index volume and dose-length product were decreased by 63.8% and 64%, respectively, in group B (P < 0.001 for both). Conclusion Visipaque

  10. [Computed tomography and cranial paleoanthropology].

    Science.gov (United States)

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils.

  11. Correlation between Abdominal Perforator Vessels Identified with Preoperative Computed Tomography Angiography and Intraoperative Fluorescent Angiography in the Microsurgical Breast Reconstruction Patient.

    Science.gov (United States)

    Pestana, Ivo A; Crantford, J Clayton; Zenn, Michael R

    2014-05-06

    Background Computed tomography angiography (CTA) has become a reliable method of perforator vessel identification. Indocyanine green laser-assisted fluorescent angiography (ICGLA) produces a real-time image of large and small caliber blood vessels. The aim of this prospective study was to compare ICGLA with CTA to evaluate its reliability of vessel identification and correlation to perforator vessel size and number determined preoperatively by CTA. The effect of both imaging techniques on flap design or intraoperative plan was also evaluated. Methods Over a 1-year period, patients presenting for free-tissue transfer breast reconstruction underwent preoperative CTA mapping of abdominal perforators followed by intraoperative ICGLA. Using visualization software, scaling factors were calculated so that CTA and ICGLA data could be compared. Results A total of 18 patients (24 breast reconstructions) were included. Larger CTA perforator size was associated with larger actual size (p = 0.04). The largest CTA perforator or largest actual perforator was used 78% of the time. Increasing body mass index was not associated with larger CTA perforator size (p = 0.67) or more intense ICGLA blushes (p = 0.13). No significant correlation was found between CTA perforator location and ICGLA skin blush location, size, or intensity. CTA- or ICGLA-guided intraoperative procedure adjustments were done in 72% of the patients. ICGLA identified poor soft tissue perfusion and guided flap resection in 46% of the patients. Conclusions ICGLA skin blush location, size, and intensity does not correlate with CTA-identified perforating vessel location or actual perforating vessel size. Despite this, the ICGLA information was useful for evaluation of soft tissue perfusion and flap design. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Cone-beam computed tomography evaluation of the maxillofacial features of patients with unilateral temporomandibular joint ankylosis undergoing condylar reconstruction with an autogenous coronoid process graft.

    Science.gov (United States)

    Liu, Li; Li, Jiayang; Ji, Huanzhong; Zhang, Nian; Wang, Yiyao; Zheng, Guangning; Wang, Hu; Luo, En

    2017-01-01

    To evaluate the changes in the jaws and the upper airways of unilateral temporomandibular joint ankylosis patients who underwent condylar reconstruction via autogenous coronoid process grafts using cone-beam computed tomography (CBCT). The 27 included patients underwent CBCT examinations at three stages: T0 (within two weeks before surgery), T1 (two weeks after surgery), and T2 (an average of 13 months after surgery). Forty items related to the maxillofacial hard tissues and the upper airway collected at the three times and the coronoid process graft volumes after surgery were compared. Some integral items related to the mandibular hard tissues exhibited statistical difference shortly after surgery. Some integral items related to maxillofacial hard tissues changing obviously long period after surgery may result from graft remodeling. Asymmetry-related item regarding local neo-condyle and some airway items were significantly different between T0 and T1. Due to variations in graft remodeling, some related local asymmetry items and airway items differed significantly between T0 and T2. Anteriorly and inferiorly located neo-condyles and a trend toward the pronation of the mandible were observed and the narrowness of the upper airway was improved shortly after surgery. The grafts remodeled differently and some integral and asymmetry items related to neo-condyle changed. The improvements in the upper airway were slightly reduced.

  13. A novel region-growing based semi-automatic segmentation protocol for three-dimensional condylar reconstruction using cone beam computed tomography (CBCT.

    Directory of Open Access Journals (Sweden)

    Tong Xi

    Full Text Available OBJECTIVE: To present and validate a semi-automatic segmentation protocol to enable an accurate 3D reconstruction of the mandibular condyles using cone beam computed tomography (CBCT. MATERIALS AND METHODS: Approval from the regional medical ethics review board was obtained for this study. Bilateral mandibular condyles in ten CBCT datasets of patients were segmented using the currently proposed semi-automatic segmentation protocol. This segmentation protocol combined 3D region-growing and local thresholding algorithms. The segmentation of a total of twenty condyles was performed by two observers. The Dice-coefficient and distance map calculations were used to evaluate the accuracy and reproducibility of the segmented and 3D rendered condyles. RESULTS: The mean inter-observer Dice-coefficient was 0.98 (range [0.95-0.99]. An average 90th percentile distance of 0.32 mm was found, indicating an excellent inter-observer similarity of the segmented and 3D rendered condyles. No systematic errors were observed in the currently proposed segmentation protocol. CONCLUSION: The novel semi-automated segmentation protocol is an accurate and reproducible tool to segment and render condyles in 3D. The implementation of this protocol in the clinical practice allows the CBCT to be used as an imaging modality for the quantitative analysis of condylar morphology.

  14. Do reduction and healing of the bony fragment really matter in arthroscopic bony Bankart reconstruction?: a prospective study with clinical and computed tomography evaluations.

    Science.gov (United States)

    Jiang, Chun-Yan; Zhu, Yi-Ming; Liu, Xin; Li, Feng-Long; Lu, Yi; Wu, Guan

    2013-11-01

    Bony Bankart lesions can be treated with arthroscopic repair. However, few studies have evaluated the importance of bony fragment reduction and healing to stability of the glenohumeral joint after arthroscopic bony Bankart repair. To evaluate functional results after surgery and determine the correlation between reduction and healing of the fracture and postoperative stability of the glenohumeral joint. Case series; Level of evidence, 4. A total of 50 patients (47 men, 3 women; average age, 27.6 years; range, 16.5-50.1 years) with bony Bankart lesions and recurrent anterior shoulder dislocations were treated with arthroscopic reduction and internal fixation with suture anchors. The average follow-up period was 32.5 months (range, 24.3-61.2 months). Preoperative and postoperative range of motion and American Shoulder and Elbow Surgeons (ASES), Constant-Murley, and Rowe scores were compared to evaluate the results of the surgeries. Sequential 3-dimensional computed tomography (CT) scans were available for 37 patients and were analyzed to investigate the effect of the bony defect of the glenoid and the correlation between the success of the surgery and reduction and healing of the bony fragment. After surgery, active forward elevation was significantly improved (P 80% in all of the successful cases. Arthroscopic reduction and fixation of a bony Bankart lesion can achieve good results in selected cases. The size of the reconstructed glenoid is crucial to the success of the surgery.

  15. Intraosseous focal venous malformation of the mandibular body: Cone beam computed tomography planning followed by piezoelectric knife resection and free bone graft reconstruction

    Directory of Open Access Journals (Sweden)

    Nikolić Živorad S.

    2017-01-01

    Full Text Available Introduction. Intraosseous vascular malformation could be life-threatening due to uncontrolled hemorrhage after tooth extraction. According to biological behavior of this lesion, adequate diagnostic and treatment strategies are necessary in order to avoid possible complications. We reported cone beam computed tomography (CBCT planning of an urgent en bloc resection of an intraosseous venous malformation by piezoelectric knife. Case report. A 55-year-old man was submitted to CBCT planning followed by piezoelectric knife resection of an intraosseous focal venous malformation of the mandibular body. Immediate reconstruction of the defect using iliac bone free graft was performed. The surgical treatment was uneventful and a 2-year follow-up revealed no signs of recurrence. Conclusion. Piezoelectric knife could provide precise, safe and bloodless procedure which is especially important in this pathology. Advantages of this technique are: lower risk of damaging soft tissue structures, precise osteotomy and bloodless surgery. Moreover, using piezosurgery bone knife, blood transfusion and blood transmitted diseases could be avoided. This case highlights the importance of CBCT as planning tool for resection of the mandible, using piezoelectric knife as safe method to achieve bloodless surgery. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 175075

  16. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... What are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  2. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  3. Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Lin; Liang, Changhong [Southern Medical University, Guangzhou (China); Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China); Zhuang, Jian [Guangdong Academy of Medical Sciences, Dept. of Cardiac Surgery, Guangdong Cardiovascular Inst., Guangdong Provincial Key Lab. of South China Structural Heart Disease, Guangdong General Hospital, Guangzhou (China); Huang, Meiping [Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China); Guangdong Academy of Medical Sciences, Dept. of Catheterization Lab, Guangdong Cardiovascular Inst., Guangdong Provincial Key Lab. of South China Structural Heart Disease, Guangdong General Hospital, Guangzhou (China); Liu, Hui [Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China)

    2017-01-15

    Hybrid iterative reconstruction can reduce image noise and produce better image quality compared with filtered back-projection (FBP), but few reports describe optimization of the iteration level. We optimized the iteration level of iDose{sup 4} and evaluated image quality for pediatric cardiac CT angiography. Children (n = 160) with congenital heart disease were enrolled and divided into full-dose (n = 84) and half-dose (n = 76) groups. Four series were reconstructed using FBP, and iDose{sup 4} levels 2, 4 and 6; we evaluated subjective quality of the series using a 5-grade scale and compared the series using a Kruskal-Wallis H test. For FBP and iDose{sup 4}-optimal images, we compared contrast-to-noise ratios (CNR) and size-specific dose estimates (SSDE) using a Student's t-test. We also compared diagnostic-accuracy of each group using a Kruskal-Wallis H test. Mean scores for iDose{sup 4} level 4 were the best in both dose groups (all P < 0.05). CNR was improved in both groups with iDose{sup 4} level 4 as compared with FBP. Mean decrease in SSDE was 53% in the half-dose group. Diagnostic accuracy for the four datasets were in the range 92.6-96.2% (no statistical difference). iDose{sup 4} level 4 was optimal for both the full- and half-dose groups. Protocols with iDose{sup 4} level 4 allowed 53% reduction in SSDE without significantly affecting image quality and diagnostic accuracy. (orig.)

  4. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  5. Time-resolved computed tomography of the liver: retrospective, multi-phase image reconstruction derived from volumetric perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Michael A.; Kartalis, Nikolaos; Aspelin, Peter; Albiin, Nils; Brismar, Torkel B. [Karolinska University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm (Sweden); Leidner, Bertil; Svensson, Anders [Karolinska University Hospital, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm (Sweden); Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden)

    2014-01-15

    To assess feasibility and image quality (IQ) of a new post-processing algorithm for retrospective extraction of an optimised multi-phase CT (time-resolved CT) of the liver from volumetric perfusion imaging. Sixteen patients underwent clinically indicated perfusion CT using 4D spiral mode of dual-source 128-slice CT. Three image sets were reconstructed: motion-corrected and noise-reduced (MCNR) images derived from 4D raw data; maximum and average intensity projections (time MIP/AVG) of the arterial/portal/portal-venous phases and all phases (total MIP/ AVG) derived from retrospective fusion of dedicated MCNR split series. Two readers assessed the IQ, detection rate and evaluation time; one reader assessed image noise and lesion-to-liver contrast. Time-resolved CT was feasible in all patients. Each post-processing step yielded a significant reduction of image noise and evaluation time, maintaining lesion-to-liver contrast. Time MIPs/AVGs showed the highest overall IQ without relevant motion artefacts and best depiction of arterial and portal/portal-venous phases respectively. Time MIPs demonstrated a significantly higher detection rate for arterialised liver lesions than total MIPs/AVGs and the raw data series. Time-resolved CT allows data from volumetric perfusion imaging to be condensed into an optimised multi-phase liver CT, yielding a superior IQ and higher detection rate for arterialised liver lesions than the raw data series. (orig.)

  6. Increased accuracy of single photon emission computed tomography (SPECT myocardial perfusion scintigraphy using iterative reconstruction of images

    Directory of Open Access Journals (Sweden)

    Stević Miloš

    2016-01-01

    Full Text Available Background/Aim. Filtered back projection (FBP is a common way of processing myocardial perfusion imaging (MPI studies. There are artifacts in FBP which can cause falsepositive results. Iterative reconstruction (IR is developed to reduce false positive findings in MPI studies. The aim of this study was to evaluate the difference in the number of false positive findings in MPI studies, between FBP and IR processing. Methods. We examined 107 patients with angina pectoris with MPI and coronary angiography (CAG, 77 man and 30 woman, aged 32−82. MPI studies were processed with FBP and with IR. Positive finding at MPI was visualization of the perfusion defect. Positive finding at CAG was stenosis of coronary artery. Perfusion defect at MPI without coronary artery stenosis at CAG was considered like false positive. The results were statistically analyzed with bivariate correlation, and with one sample t-test. Results. There were 20.6% normal, and 79.4% pathologic findings at FBP, 30.8% normal and 69.2% pathologic with IR and 37.4% normal and 62.6% pathologic at CAG. FBP produced 19 false-positive findings, at IR 11 false positive findings. The correlation between FBP and CAG was 0.658 (p < 0.01 and between IR and CAG 0.784 (p < 0.01. The number of false positive findings at MPI with IR was significantly lower than at FBP (p < 0.01. Conclusion. Our study shows that IR processing MPI scintigraphy has less number of false positive findings, therefore it is our choice for processing MPI studies.

  7. Geometric reconstruction methods for electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Alpers, Andreas, E-mail: alpers@ma.tum.de [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany); Gardner, Richard J., E-mail: Richard.Gardner@wwu.edu [Department of Mathematics, Western Washington University, Bellingham, WA 98225-9063 (United States); König, Stefan, E-mail: koenig@ma.tum.de [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany); Pennington, Robert S., E-mail: robert.pennington@uni-ulm.de [Center for Electron Nanoscopy, Technical University of Denmark, DK-2800 Kongens Lyngby (Denmark); Boothroyd, Chris B., E-mail: ChrisBoothroyd@cantab.net [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Houben, Lothar, E-mail: l.houben@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Dunin-Borkowski, Rafal E., E-mail: rdb@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Joost Batenburg, Kees, E-mail: Joost.Batenburg@cwi.nl [Centrum Wiskunde and Informatica, NL-1098XG, Amsterdam, The Netherlands and Vision Lab, Department of Physics, University of Antwerp, B-2610 Wilrijk (Belgium)

    2013-05-15

    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts and non-linear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full 180° tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce and discuss several algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed for the reconstruction of an InAs nanowire. - Highlights: ► Four algorithms for electron tomography are introduced that utilize prior knowledge. ► Objects are assumed to be homogeneous; convexity and regularity is also discussed. ► We are able to reconstruct slices of a nanowire from as few as four projections. ► Algorithms should be selected based on the specific reconstruction task at hand.

  8. Image Reconstruction Algorithm for Electrical Charge Tomography System

    Directory of Open Access Journals (Sweden)

    M. F. Rahmat

    2010-01-01

    Full Text Available Problem statement: Many problems in scientific computing can be formulated as inverse problem. A vast majority of these problems are ill-posed problems. In Electrical Charge Tomography (EChT, normally the sensitivity matrix generated from forward modeling is very ill-condition. This condition posts difficulties to the inverse problem solution especially in the accuracy and stability of the image being reconstructed. The objective of this study is to reconstruct the image cross-section of the material in pipeline gravity dropped mode conveyor as well to solve the ill-condition of matrix sensitivity. Approach: Least Square with Regularization (LSR method had been introduced to reconstruct the image and the electrodynamics sensor was used to capture the data that installed around the pipe. Results: The images were validated using digital imaging technique and Singular Value Decomposition (SVD method. The results showed that image reconstructed by this method produces a good promise in terms of accuracy and stability. Conclusion: This implied that LSR method provides good and promising result in terms of accuracy and stability of the image being reconstructed. As a result, an efficient method for electrical charge tomography image reconstruction has been introduced.

  9. Validation of the Gate simulation platform in single photon emission computed tomography and application to the development of a complete 3-dimensional reconstruction algorithm; Validation de la plate-forme de simulation GATE en tomographie a emission monophotonique et application au developpement d'un algorithme de reconstruction 3D complete

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, D

    2003-10-01

    Monte Carlo simulations are currently considered in nuclear medical imaging as a powerful tool to design and optimize detection systems, and also to assess reconstruction algorithms and correction methods for degrading physical effects. Among the many simulators available, none of them is considered as a standard in nuclear medical imaging: this fact has motivated the development of a new generic Monte Carlo simulation platform (GATE), based on GEANT4 and dedicated to SPECT/PET (single photo emission computed tomography / positron emission tomography) applications. We participated during this thesis to the development of the GATE platform within an international collaboration. GATE was validated in SPECT by modeling two gamma cameras characterized by a different geometry, one dedicated to small animal imaging and the other used in a clinical context (Philips AXIS), and by comparing the results obtained with GATE simulations with experimental data. The simulation results reproduce accurately the measured performances of both gamma cameras. The GATE platform was then used to develop a new 3-dimensional reconstruction method: F3DMC (fully 3-dimension Monte-Carlo) which consists in computing with Monte Carlo simulation the transition matrix used in an iterative reconstruction algorithm (in this case, ML-EM), including within the transition matrix the main physical effects degrading the image formation process. The results obtained with the F3DMC method were compared to the results obtained with three other more conventional methods (FBP, MLEM, MLEMC) for different phantoms. The results of this study show that F3DMC allows to improve the reconstruction efficiency, the spatial resolution and the signal to noise ratio with a satisfactory quantification of the images. These results should be confirmed by performing clinical experiments and open the door to a unified reconstruction method, which could be applied in SPECT but also in PET. (author)

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  14. An Effective CUDA Parallelization of Projection in Iterative Tomography Reconstruction.

    Science.gov (United States)

    Xie, Lizhe; Hu, Yining; Yan, Bin; Wang, Lin; Yang, Benqiang; Liu, Wenyuan; Zhang, Libo; Luo, Limin; Shu, Huazhong; Chen, Yang

    2015-01-01

    Projection and back-projection are the most computationally intensive parts in Computed Tomography (CT) reconstruction, and are essential to acceleration of CT reconstruction algorithms. Compared to back-projection, parallelization efficiency in projection is highly limited by racing condition and thread unsynchronization. In this paper, a strategy of Fixed Sampling Number Projection (FSNP) is proposed to ensure the operation synchronization in the ray-driven projection with Graphical Processing Unit (GPU). Texture fetching is also used utilized to further accelerate the interpolations in both projection and back-projection. We validate the performance of this FSNP approach using both simulated and real cone-beam CT data. Experimental results show that compare to the conventional approach, the proposed FSNP method together with texture fetching is 10~16 times faster than the conventional approach based on global memory, and thus leads to more efficient iterative algorithm in CT reconstruction.

  15. An Effective CUDA Parallelization of Projection in Iterative Tomography Reconstruction.

    Directory of Open Access Journals (Sweden)

    Lizhe Xie

    Full Text Available Projection and back-projection are the most computationally intensive parts in Computed Tomography (CT reconstruction, and are essential to acceleration of CT reconstruction algorithms. Compared to back-projection, parallelization efficiency in projection is highly limited by racing condition and thread unsynchronization. In this paper, a strategy of Fixed Sampling Number Projection (FSNP is proposed to ensure the operation synchronization in the ray-driven projection with Graphical Processing Unit (GPU. Texture fetching is also used utilized to further accelerate the interpolations in both projection and back-projection. We validate the performance of this FSNP approach using both simulated and real cone-beam CT data. Experimental results show that compare to the conventional approach, the proposed FSNP method together with texture fetching is 10~16 times faster than the conventional approach based on global memory, and thus leads to more efficient iterative algorithm in CT reconstruction.

  16. The posterior communicating artery: morphometric study in 3D angio-computed tomography reconstruction. The proof of the mathematical definition of the hypoplasia.

    Science.gov (United States)

    Dzierżanowski, J; Szarmach, A; Słoniewski, P; Czapiewski, P; Piskunowicz, M; Bandurski, T; Szmuda, T

    2014-08-01

    The aim of this study was to investigate the morphometry of the posterior communicating artery (PCoA), on the basis of angio-computed tomography (CT), and to give proof of the mathematical definition of the term "hypopal sia of the PCoA". One hundred 3-dimensional (3D) angio-CT images, performed in adult patients with bilateral reconstruction of the PCoA (200 results) were used tocalculate the morphometry of the vessel. The average length of the vessel on the right side was 14.48 ± 3.47 mm, andon the left side 14.98 ± 4.77 mm (in women 14.75 mm, in men 14.70 mm). The mean of the diameter at the "proximal" point (the junction with P1) on the right side was 1.49 ± 0.51 mm, and on the left 1.46 ± 0.47 mm (in women 1.44 mm and in men 1.51 mm). The mean of the diameter in the "distal" part (the connection with ICA) on the right side was 1.4 ± 0.49 mm, and on the left 1.37 ± 0.41 mm (in women 1.38 mm, and in men 1.39 mm). No statistical correlation between the length and the diameter of the PCoA in relation to the sex and side was shown. On the basis of our measurements, we defined the hypoplasia of the artery as the estimated value less than the average diameter minus the standard deviation. The percentage distribution was as follows: the left artery 15.5%, the right artery 24%, women 11.5%, and the men 9%. Similarly to the above parameters, we have not found any statistical differences. The presence of the foetal origin was noted in 25% of the radiological examinations. The infundibular widening was visualised in 11.5% of cases of 3D reconstructions. The agenesis of PCoA was found in 9% (never bilaterally), and in 1 case the unilateral duplication of the artery was observed. No statistical differences between those parameters in relation to sex and the examined side were revealed. Morphological calculation of the PCoA on the basis of angio-CT from adult patients did not show any statistical differences depending on sex or the investigated side. The presented

  17. Functional and computed tomography correlation of femoral and tibial tunnels in single-bundle anterior cruciate ligament reconstruction: Use of accessory anteromedial portal

    Science.gov (United States)

    Mathai, Naveen Joseph; Amaravathi, Rajkumar S; Pavan, KV; Sekaran, Padmanabhan; Sharma, Gaurav; Codanda, Belliappa

    2016-01-01

    Background: An accessory anteromedial portal (AAMP) has been shown to be effective in placing an anatomically ideal femoral tunnel. It is well known that this is due to the independent femoral drilling which is possible with the AAMP. However very little is known regarding the significance of this reconstruction technique in influencing the functional outcomes of anatomic anterior cruciate ligament reconstruction (ACLR). This study documents the influence of tibial and femoral tunnel positions on functional outcomes of anatomic ACLR using the AAMP. Materials and Methods: 41 patients who underwent anatomic ACLR between 2011 and 2013 were included in this prospective cohort study. The primary outcome involved the documentation of femoral and tibial tunnel positions with volume rendering imaging using a three-dimensional computed tomography (3D-CT) done at the end of 1 year. The tunnel position evaluations from the CT images were performed by an independent observer specializing in radiodiagnosis. Functional outcome measures included preoperative and postoperative Lysholm and International Knee Documentation Committee (IKDC) scores (subjective) documented by an independent investigator who was not involved with the surgical procedure, at the end of 1 year. Results: The minimum followup was 1 year. All patients achieved good clinical and functional outcomes postoperatively with no reported complications. Tunnel position evaluations with 3D-CT revealed the average tibial tunnel distance to be 15.5 mm (standard deviation [SD] =2.52) from the anterior border of the tibial plateau and the average femoral tunnel distance to be 14.33 mm (SD = 2.6) from the inferior margin of the medial surface of lateral femoral condyle and 13.72 mm (SD = 2.8) from the posterior margin of the medial surface of lateral femoral condyle. The average tunnel diameters were found to be 7.9 mm (SD = 0.72) for the tibial tunnels and 8.6 mm (SD = 1.07) for the femoral tunnels. Statistically

  18. Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography

    NARCIS (Netherlands)

    Hassan, B.; Souza, P.C.; Jacobs, R.; Berti, S.D.; van der Stelt, P.

    2010-01-01

    The study aim is to investigate the influence of scan field, mouth opening, voxel size, and segmentation threshold selections on the quality of the three-dimensional (3D) surface models of the dental arches from cone beam computed tomography (CBCT). 3D models of 25 patients scanned with one image in

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  7. Case series of 64 slice computed tomography-computed tomographic angiography with 3D reconstruction to diagnose symptomatic cerebral aneurysms: new standard of care?

    Directory of Open Access Journals (Sweden)

    Dietrich Jehle

    2012-02-01

    Full Text Available CT angiography (CTA has improved significantly over the past few years such that the reconstructed images of the cerebral arteries may now be equivalent to conventional digital angiography. The new technology of 64 slice multi-detector CTA can reconstruct detailed images that can reliably identify small cerebral aneurysms, even those <3mm. In addition, it is estimated that CT followed by lumbar puncture (LP misses up to 4% of symptomatic aneurysms. We present a series of cases that illustrates how CT followed by CTA may be replacing CT-LP as the standard of care in working up patients for symptomatic cerebral aneurysms and the importance of performing three dimensional (3D reconstructions. A series of seven cases of symptomatic cerebral aneurysms were identified that illustrate the sensitivity of CT-CTA versus CT-LP and the importance of 3D reconstruction in identifying these aneurysms. Surgical treatment was recommended for 6 of the 7 patients with aneurysms and strict hypertension control was recommended for the seventh patient. Some of these patients demonstrated subarachnoid hemorrhage on presentation while others had negative LPs. A number of these patients with negative LPs were clearly symptomatic from their aneurysms. At least one of these cerebral aneurysms was not apparent on CTA without 3D reconstruction. 3D reconstruction of CTA is crucial to adequately identify cerebral aneurysms. This case series helps reinforce the importance of 3D reconstruction. There is some data to suggest that 64 slice CT-CTA may be equivalent or superior to CT-LP in the detection of symptomatic cerebral aneurysms.

  8. Geometric reconstruction methods for electron tomography

    CERN Document Server

    Alpers, Andreas; König, Stefan; Pennington, Robert S; Boothroyd, Chris B; Houben, Lothar; Dunin-Borkowski, Rafal E; Batenburg, Kees Joost

    2012-01-01

    Electron tomography is becoming an increasingly important tool in materials science for studying three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts and nonlinear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full $180^\\circ$ tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce four algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed for the reconstruction of an InAs nanowire.

  9. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  10. Comparison of volumetric bone mineral density in the operated and contralateral knee after anterior cruciate ligament and reconstruction: A 1-year follow-up study using peripheral quantitative computed tomography.

    Science.gov (United States)

    Mündermann, Annegret; Payer, Nina; Felmet, Gernot; Riehle, Hartmut

    2015-12-01

    The purpose of this study was to quantify changes in volumetric bone mineral density (vBMD) in the tibial plateau of the operated and contralateral leg measured using peripheral quantitative computed tomography (pQCT) before and 3, 6, and 12 months after anterior cruciate ligament (ACL) reconstruction. The ACL was reconstructed with a hamstring tendon autograft using press-fit fixation. pQCT measurements of the proximal tibia were obtained in 61 patients after ACL reconstruction, and total, cortical, and trabecular vBMD were calculated. vBMD in the operated leg decreased from baseline to 3 months (-12% [total], -11% [cortical], and -12.6% [trabecular]; preconstruction contributed to loss in bone mineral density within the first year after surgery. The role of factors such as time of weight-bearing, joint mechanics, post-traumatic inflammatory reactions, or genetic predisposition in modulating the development of posttraumatic knee osteoarthritis after ACL injury should be further elucidated.

  11. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  12. Cranial computed tomography in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Boltshauser, E. (Zuerich Univ. (Switzerland). Kinderklinik)

    1984-01-01

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect to probable therapeutic consequences and expected diagnostic yield. In the view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy.

  13. Reconstruction of an InAs nanowire using geometric tomography

    DEFF Research Database (Denmark)

    Pennington, Robert S.; König, Stefan; Alpers, Andreas;

    Geometric tomography and conventional algebraic tomography algorithms are used to reconstruct cross-sections of an InAs nanowire from a tilt series of experimental annular dark-field images. Both algorithms are also applied to a test object to assess what factors affect the reconstruction quality...

  14. Dose fractionation theorem in 3-D reconstruction (tomography)

    Energy Technology Data Exchange (ETDEWEB)

    Glaeser, R.M. [Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    It is commonly assumed that the large number of projections for single-axis tomography precludes its application to most beam-labile specimens. However, Hegerl and Hoppe have pointed out that the total dose required to achieve statistical significance for each voxel of a computed 3-D reconstruction is the same as that required to obtain a single 2-D image of that isolated voxel, at the same level of statistical significance. Thus a statistically significant 3-D image can be computed from statistically insignificant projections, as along as the total dosage that is distributed among these projections is high enough that it would have resulted in a statistically significant projection, if applied to only one image. We have tested this critical theorem by simulating the tomographic reconstruction of a realistic 3-D model created from an electron micrograph. The simulations verify the basic conclusions of high absorption, signal-dependent noise, varying specimen contrast and missing angular range. Furthermore, the simulations demonstrate that individual projections in the series of fractionated-dose images can be aligned by cross-correlation because they contain significant information derived from the summation of features from different depths in the structure. This latter information is generally not useful for structural interpretation prior to 3-D reconstruction, owing to the complexity of most specimens investigated by single-axis tomography. These results, in combination with dose estimates for imaging single voxels and measurements of radiation damage in the electron microscope, demonstrate that it is feasible to use single-axis tomography with soft X-ray microscopy of frozen-hydrated specimens.

  15. Sparsity reconstruction in electrical impedance tomography: An experimental evaluation

    KAUST Repository

    Gehre, Matthias

    2012-02-01

    We investigate the potential of sparsity constraints in the electrical impedance tomography (EIT) inverse problem of inferring the distributed conductivity based on boundary potential measurements. In sparsity reconstruction, inhomogeneities of the conductivity are a priori assumed to be sparse with respect to a certain basis. This prior information is incorporated into a Tikhonov-type functional by including a sparsity-promoting ℓ1-penalty term. The functional is minimized with an iterative soft shrinkage-type algorithm. In this paper, the feasibility of the sparsity reconstruction approach is evaluated by experimental data from water tank measurements. The reconstructions are computed both with sparsity constraints and with a more conventional smoothness regularization approach. The results verify that the adoption of ℓ1-type constraints can enhance the quality of EIT reconstructions: in most of the test cases the reconstructions with sparsity constraints are both qualitatively and quantitatively more feasible than that with the smoothness constraint. © 2011 Elsevier B.V. All rights reserved.

  16. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Precht, Helle; Leth, Peter Mygind; Thygesen, Jesper

    2014-01-01

    Introduction: Coronary atherosclerosis is a leading cause of mortality. New technological developments in computed tomography (CT), including dual energy, iterative reconstructions and high definition scanning, could significantly improve the non-invasive identification of atherosclerosis plaques....... Here, a new method for optimising cardiac coronary CT with optical coherence tomography (OCT) and histopathology is presented. Materials and methods: Twenty human hearts obtained from autopsies were used. A contrast agent that solidifies after cooling was injected into the coronary arteries. CT...

  17. Computed tomography of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Haughton, V.M.; Williams, A.L.

    1982-01-01

    The book describes the computed tomographic (CT) techniques for imaging the different elements comprising the spinal column and canal. The use of intravenous and intrathecal contrast enhancement and of xenon enhancement is briefly mentioned. Reconstruction techniques and special problems regarding CT of the spine are presented. CT of the spinal cord, meninges and subarachnoid space, epidural space, intervertebral discs, facet joints, and vertebrae present normal anatomy, and several common pathologic conditions. (KRM)

  18. Advanced reconstruction algorithms for electron tomography: From comparison to combination

    Energy Technology Data Exchange (ETDEWEB)

    Goris, B. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Roelandts, T. [Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Batenburg, K.J. [Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Centrum Wiskunde and Informatica, Science Park 123, NL-1098XG Amsterdam (Netherlands); Heidari Mezerji, H. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Bals, S., E-mail: sara.bals@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2013-04-15

    In this work, the simultaneous iterative reconstruction technique (SIRT), the total variation minimization (TVM) reconstruction technique and the discrete algebraic reconstruction technique (DART) for electron tomography are compared and the advantages and disadvantages are discussed. Furthermore, we describe how the result of a three dimensional (3D) reconstruction based on TVM can provide objective information that is needed as the input for a DART reconstruction. This approach results in a tomographic reconstruction of which the segmentation is carried out in an objective manner. - Highlights: ► A comparative study between different reconstruction algorithms for tomography is performed. ► Reconstruction algorithms that uses prior knowledge about the specimen have a superior result. ► One reconstruction algorithm can provide the prior knowledge for a second algorithm.

  19. Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80 kV and iterative reconstruction algorithm using different concentration contrast media.

    Science.gov (United States)

    Annoni, Andrea Daniele; Mancini, Maria E; Andreini, Daniele; Formenti, Alberto; Mushtaq, Saima; Nobili, Enrica; Guglielmo, Marco; Baggiano, Andrea; Conte, Edoardo; Pepi, Mauro

    2017-03-27

    Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV. Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols. © 2017 The Royal Australian and New Zealand College of Radiologists.

  20. Novel regularized sparse model for fluorescence molecular tomography reconstruction

    Science.gov (United States)

    Liu, Yuhao; Liu, Jie; An, Yu; Jiang, Shixin

    2017-01-01

    Fluorescence molecular tomography (FMT) is an imaging modality that exploits the specificity of fluorescent biomarkers to enable 3D visualization of molecular targets and pathways in small animals. FMT has been used in surgical navigation for tumor resection and has many potential applications at the physiological, metabolic, and molecular levels in tissues. The hybrid system combined FMT and X-ray computed tomography (XCT) was pursued for accurate detection. However, the result is usually over-smoothed and over-shrunk. In this paper, we propose a region reconstruction method for FMT in which the elastic net (E-net) regularization is used to combine L1-norm and L2-norm. The E-net penalty corresponds to adding the L1-norm penalty and a L2-norm penalty. Elastic net combines the advantages of L1-norm regularization and L2-norm regularization. It could achieve the balance between the sparsity and smooth by simultaneously employing the L1-norm and the L2-norm. To solve the problem effectively, the proximal gradient algorithms was used to accelerate the computation. To evaluate the performance of the proposed E-net method, numerical phantom experiments are conducted. The simulation study shows that the proposed method achieves accurate and is able to reconstruct image effectively.

  1. Practical implementation of tetrahedral mesh reconstruction in emission tomography

    Science.gov (United States)

    Boutchko, R.; Sitek, A.; Gullberg, G. T.

    2013-05-01

    This paper presents a practical implementation of image reconstruction on tetrahedral meshes optimized for emission computed tomography with parallel beam geometry. Tetrahedral mesh built on a point cloud is a convenient image representation method, intrinsically three-dimensional and with a multi-level resolution property. Image intensities are defined at the mesh nodes and linearly interpolated inside each tetrahedron. For the given mesh geometry, the intensities can be computed directly from tomographic projections using iterative reconstruction algorithms with a system matrix calculated using an exact analytical formula. The mesh geometry is optimized for a specific patient using a two stage process. First, a noisy image is reconstructed on a finely-spaced uniform cloud. Then, the geometry of the representation is adaptively transformed through boundary-preserving node motion and elimination. Nodes are removed in constant intensity regions, merged along the boundaries, and moved in the direction of the mean local intensity gradient in order to provide higher node density in the boundary regions. Attenuation correction and detector geometric response are included in the system matrix. Once the mesh geometry is optimized, it is used to generate the final system matrix for ML-EM reconstruction of node intensities and for visualization of the reconstructed images. In dynamic PET or SPECT imaging, the system matrix generation procedure is performed using a quasi-static sinogram, generated by summing projection data from multiple time frames. This system matrix is then used to reconstruct the individual time frame projections. Performance of the new method is evaluated by reconstructing simulated projections of the NCAT phantom and the method is then applied to dynamic SPECT phantom and patient studies and to a dynamic microPET rat study. Tetrahedral mesh-based images are compared to the standard voxel-based reconstruction for both high and low signal-to-noise ratio

  2. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...... contains a survey of application examples from the manufacturing industry as well as from other industries, e.g., electrical and electronic devices, inhomogeneous materials, and from the food industry. Challenges as well as major national and international coordinated activities in the field of industrial...

  3. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    Modern diagnostic imagining techniques are gaining popularity in forensic medicine. Denmark has been involved in the development of this use of imaging techniques from the beginning. The Institute of Forensic Medicine at the University of Southern Denmark acquired a helical computed tomography (CT...... AND METHODS: This thesis investigated 900 forensic cases that were CT-scanned and autopsied at the Institute of Forensic Medicine, University of Southern Denmark, from 2006-2011. The scanner was a Siemens Somatom Spirit dual-slice CT-scanner with a Siemens Syngo MultiModality workstation. Contrast enhancement...

  4. Limited-data computed tomography algorithms for the physical sciences.

    Science.gov (United States)

    Verhoeven, D

    1993-07-10

    Five limited-data computed tomography algorithms are compared. The algorithms used are adapted versions of the algebraic reconstruction technique, the multiplicative algebraic reconstruction technique, the Gerchberg-Papoulis algorithm, a spectral extrapolation algorithm descended from that of Harris [J. Opt. Soc. Am. 54, 931-936 (1964)], and an algorithm based on the singular value decomposition technique. These algorithms were used to reconstruct phantom data with realistic levels of noise from a number of different imaging geometries. The phantoms, the imaging geometries, and the noise were chosen to simulate the conditions encountered in typical computed tomography applications in the physical sciences, and the implementations of the algorithms were optimized for these applications. The multiplicative algebraic reconstruction technique algorithm gave the best results overall; the algebraic reconstruction technique gave the best results for very smooth objects or very noisy (20-dB signal-to-noise ratio) data. My implementations of both of these algorithms incorporate apriori knowledge of the sign of the object, its extent, and its smoothness. The smoothness of the reconstruction is enforced through the use of an appropriate object model (by use of cubic B-spline basis functions and a number of object coefficients appropriate to the object being reconstructed). The average reconstruction error was 1.7% of the maximum phantom value with the multiplicative algebraic reconstruction technique of a phantom with moderate-to-steep gradients by use of data from five viewing angles with a 30-dB signal-to-noise ratio.

  5. The Role of Synthetic Reconstruction Tests in Seismic Tomography

    Science.gov (United States)

    Rawlinson, N.; Spakman, W.

    2015-12-01

    Synthetic reconstruction tests are widely used in seismic tomography as a means for assessing the robustness of solutions produced by linear or iterative non-linear inversion schemes. The most common test is the so-called checkerboard resolution test, which uses an alternating pattern of high and low wavespeeds (or some other seismic property such as attenuation). However, checkerboard tests have a number of limitations, including that they (1) only provide indirect evidence of quantitative measures of reliability such as resolution and uncertainty; (2) give a potentially misleading impression of the range of scale-lengths that can be resolved; (3) don't give a true picture of the structural distortion or smearing caused by the data coverage; and (4) result in an inverse problem that is biased towards an accurate reconstruction. The widespread use of synthetic reconstruction tests in seismic tomography is likely to continue for some time yet, so it is important to implement best practice where possible. The goal here is to provide a general set of guidelines, derived from the underlying theory and illustrated by a series of numerical experiments, on their implementation in seismic tomography. In particular, we recommend (1) using a sparse distribution of spikes, rather than the more conventional tightly-spaced checkerboard; (2) using the identical data coverage (e.g. geometric rays) for the synthetic model that was computed for the observation-based model; (3) carrying out multiple tests using anomalies of different scale length; (4) exercising caution when analysing synthetic recovery tests that use anomaly patterns that closely mimic the observation-based model; (5) investigating the trade-off between data noise levels and the minimum wavelength of recovered structure; (6) where possible, test the extent to which preconditioning (e.g. identical parameterization for input and output models) influences the recovery of anomalies.

  6. Iterative reconstruction of a region of interest for transmission tomography.

    Science.gov (United States)

    Ziegler, Andy; Nielsen, Tim; Grass, Michael

    2008-04-01

    It was shown that images reconstructed for transmission tomography with iterative maximum likelihood (ML) algorithms exhibit a higher signal-to-noise ratio than images reconstructed with filtered back-projection type algorithms. However, a drawback of ML reconstruction in particular and iterative reconstruction in general is the requirement that the reconstructed field of view (FOV) has to cover the whole volume that contributes to the absorption. In the case of a high resolution reconstruction, this demands a huge number of voxels. This article shows how an iterative ML reconstruction can be limited to a region of interest (ROI) without losing the advantages of a ML reconstruction. Compared with a full FOV ML reconstruction, the reconstruction speed is mainly increased by reducing the number of voxels which are necessary for a ROI reconstruction. In addition, the speed of convergence is increased.

  7. A Wavelet-Based Multiresolution Reconstruction Method for Fluorescent Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Wei Zou

    2009-01-01

    Full Text Available Image reconstruction of fluorescent molecular tomography (FMT often involves repeatedly solving large-dimensional matrix equations, which are computationally expensive, especially for the case where there are large deviations in the optical properties between the target and the reference medium. In this paper, a wavelet-based multiresolution reconstruction approach is proposed for the FMT reconstruction in combination with a parallel forward computing strategy, in which both the forward and the inverse problems of FMT are solved in the wavelet domain. Simulation results demonstrate that the proposed approach can significantly speed up the reconstruction process and improve the image quality of FMT.

  8. Electron tomography based on a total variation minimization reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Goris, B., E-mail: bart.goris@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Van den Broek, W. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Batenburg, K.J. [Centrum Wiskunde and Informatica, Science Park 123, NL-1098XG Amsterdam (Netherlands); Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Heidari Mezerji, H.; Bals, S. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2012-02-15

    The 3D reconstruction of a tilt series for electron tomography is mostly carried out using the weighted backprojection (WBP) algorithm or using one of the iterative algorithms such as the simultaneous iterative reconstruction technique (SIRT). However, it is known that these reconstruction algorithms cannot compensate for the missing wedge. Here, we apply a new reconstruction algorithm for electron tomography, which is based on compressive sensing. This is a field in image processing specialized in finding a sparse solution or a solution with a sparse gradient to a set of ill-posed linear equations. Therefore, it can be applied to electron tomography where the reconstructed objects often have a sparse gradient at the nanoscale. Using a combination of different simulated and experimental datasets, it is shown that missing wedge artefacts are reduced in the final reconstruction. Moreover, it seems that the reconstructed datasets have a higher fidelity and are easier to segment in comparison to reconstructions obtained by more conventional iterative algorithms. -- Highlights: Black-Right-Pointing-Pointer A reconstruction algorithm for electron tomography is investigated based on total variation minimization. Black-Right-Pointing-Pointer Missing wedge artefacts are reduced by this algorithm. Black-Right-Pointing-Pointer The reconstruction is easier to segment. Black-Right-Pointing-Pointer More reliable quantitative information can be obtained.

  9. A practical local tomography reconstruction algorithm based on known subregion

    CERN Document Server

    Paleo, Pierre; Mirone, Alessandro

    2016-01-01

    We propose a new method to reconstruct data acquired in a local tomography setup. This method uses an initial reconstruction and refines it by correcting the low frequency artifacts known as the cupping effect. A basis of Gaussian functions is used to correct the initial reconstruction. The coefficients of this basis are iteratively optimized under the constraint of a known subregion. Using a coarse basis reduces the degrees of freedom of the problem while actually correcting the cupping effect. Simulations show that the known region constraint yields an unbiased reconstruction, in accordance to uniqueness theorems stated in local tomography.

  10. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can "instantaneously"...

  11. Advanced reconstruction algorithms for electron tomography: from comparison to combination.

    Science.gov (United States)

    Goris, B; Roelandts, T; Batenburg, K J; Heidari Mezerji, H; Bals, S

    2013-04-01

    In this work, the simultaneous iterative reconstruction technique (SIRT), the total variation minimization (TVM) reconstruction technique and the discrete algebraic reconstruction technique (DART) for electron tomography are compared and the advantages and disadvantages are discussed. Furthermore, we describe how the result of a three dimensional (3D) reconstruction based on TVM can provide objective information that is needed as the input for a DART reconstruction. This approach results in a tomographic reconstruction of which the segmentation is carried out in an objective manner. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...... concerns measurements of each single carcass, to improve the raw material utilisation by individually adapted processing. Measurements performed online in the abattoir demand fast, robust and cost-effective imaging. We propose a tomographic reconstruction algorithm, enabling a substantial reduction...... of the subject-specific X-ray data needed to produce high quality images for accurate measurements. This is very beneficial for the abattoirs, as a reduction in acquired data translates directly into higher speed and a lower cost. The thesis demonstrates the great potential of CT as a technology for improving...

  13. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...... table position. Advances in reconstruction algorithms make it possible to reduce the radiation dose for each examination to acceptable levels. Regarding abdominal imaging, CT perfusion is still considered a research tool, but several studies have proven it as a reliable non-invasive technique...... for assessment of vascularity. CT perfusion has also been used for tumor characterization, staging of disease, response evaluation of newer drugs targeted towards angiogenesis and as a method for early detection of recurrence after radiation and embolization. There are several software solutions available...

  14. Ultra-high resolution computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2002-01-01

    A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

  15. Massively parallel computers for 3D single-photon-emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Butler, C.S.; Miller, M.I. (Washington Univ., St. Louis, MO (United States). Electronic Systems and Signals Research Lab.); Miller, T.R.; Wallis, J.W. (Washington Univ., St. Louis, MO (United States). Edward Mallinckrodt Inst. of Radiology)

    1994-03-01

    Since the introduction of the expectation-maximization (EM) algorithm for generating maximum-likelihood (ML) and maximum a posteriori (MAP) estimates in emission tomography, there have been many investigators applying the ML method. However, almost all of the previous work has been restricted to two-dimensional (2D) reconstructions. The major focus and contribution of this paper is to demonstrate a fully three-dimensional (3D) implementation of the MAP method for single-photon-emission computed tomography (SPECT). The 3D reconstruction exhibits an improvement in resolution when compared to the generation of the series of separate 2D slice reconstructions. (Author).

  16. Comparison of Computed Tomography Scout Based Reference Point Localization to Conventional Film and Axial Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C.H., E-mail: jchu@rush.edu

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  17. Computed tomography of the gallbladder.

    Science.gov (United States)

    Havrilla, T R; Reich, N E; Haaga, J R; Seidelmann, F E; Cooperman, A M; Alfidi, R J

    1978-06-01

    Computed tomography (CT) was used to study 79 patients with suspected gallbladder disease. First and second generation scanners were used to determine the efficacy of CT in detecting cholecystitis or cholelithiasis. Manifestations of gallbladder disease such as hydrops, opaque and nonopaque gallstones, chronic cholecystitis with thickened inflammatory walls, and secondary liver abscesses can be easily detected. It is a useful technique for individuals in whom the gallbladder has failed to opacity on oral cholecystography. The scanning method is described, and estimates of reliability are given including its accuracy, limitations, and place in the management of gallbladder disease, especially cholelithiasis. When conventional radiographic examinations or ultrasound fail to give definitive diagnostic information, CT can be a useful alternative with an overall diagnostic accuracy greater than 80%.

  18. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  19. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  20. Investigation of limited-view image reconstruction in optoacoustic tomography employing a priori structural information

    Science.gov (United States)

    Huang, Chao; Oraevsky, Alexander A.; Anastasio, Mark A.

    2010-08-01

    Optoacoustic tomography (OAT) is an emerging ultrasound-mediated biophotonic imaging modality that has exciting potential for many biomedical imaging applications. There is great interest in conducting B-mode ultrasound and OAT imaging studies for breast cancer detection using a common transducer. In this situation, the range of tomographic view angles is limited, which can result in distortions in the reconstructed OAT image if conventional reconstruction algorithms are applied to limited-view measurement data. In this work, we investigate an image reconstruction method that utilizes information regarding target boundaries to improve the quality of the reconstructed OAT images. This is accomplished by developing boundary-constrained image reconstruction algorithm for OAT based on Bayesian image reconstruction theory. The computer-simulation studies demonstrate that the Bayesian approach can effectively reduce the artifact and noise levels and preserve the edges in reconstructed limited-view OAT images as compared to those produced by a conventional OAT reconstruction algorithm.

  1. Three-dimensional reconstruction in free-space whole-body fluorescence tomography of mice using optically reconstructed surface and atlas anatomy

    Science.gov (United States)

    Zhang, Xiaofeng; Badea, Cristian T.; Johnson, G. Allan

    2009-11-01

    We present a 3-D image reconstruction method for free-space fluorescence tomography of mice using hybrid anatomical prior information. Specifically, we use an optically reconstructed surface of the experimental animal and a digital mouse atlas to approximate the anatomy of the animal as structural priors to assist image reconstruction. Experiments are carried out on a cadaver of a nude mouse with a fluorescent inclusion (2.4-mm-diam cylinder) implanted in the chest cavity. Tomographic fluorescence images are reconstructed using an iterative algorithm based on a finite element method. Coregistration of the fluorescence reconstruction and micro-CT (computed tomography) data acquired afterward show good localization accuracy (localization error 1.2+/-0.6 mm). Using the optically reconstructed surface, but without the atlas anatomy, image reconstruction fails to show the fluorescent inclusion correctly. The method demonstrates the utility of anatomical priors in support of free-space fluorescence tomography.

  2. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19, ... The ECG is also needed to help the computer that is connected to the CT scanner create ...

  3. RADIATION DOSE IN PAEDIATRIC COMPUTED TOMOGRAPHY ...

    African Journals Online (AJOL)

    Computed tomography (CT) is a powerful tool for the accurate ... increasing, and estimates suggest that quantitative lifetime ... Keywords: Computed Tomography, Radiation Risk, Radiation Dose, Patient Dose ... techniques, such as MRI and ultrasound, which do not ..... in the course of management are not monitored to.

  4. The reconstructed residual error: a novel segmentation evaluation measure for reconstructed images in tomography

    NARCIS (Netherlands)

    Roelandts, T.; Batenburg, K.J.; Dekker, A.J. den; Sijbers, J.

    2014-01-01

    In this paper, we present the reconstructed residual error, which evaluates the quality of a given segmentation of a reconstructed image in tomography. This novel evaluation method, which is independent of the methods that were used to reconstruct and segment the image, is applicable to segmentation

  5. Accelerating image reconstruction in three-dimensional optoacoustic tomography on graphics processing units.

    Science.gov (United States)

    Wang, Kun; Huang, Chao; Kao, Yu-Jiun; Chou, Cheng-Ying; Oraevsky, Alexander A; Anastasio, Mark A

    2013-02-01

    Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional imaging models. One important reason is because 3D image reconstruction is computationally burdensome. The aim of this work is to accelerate existing image reconstruction algorithms for 3D OAT by use of parallel programming techniques. Parallelization strategies are proposed to accelerate a filtered backprojection (FBP) algorithm and two different pairs of projection/backprojection operations that correspond to two different numerical imaging models. The algorithms are designed to fully exploit the parallel computing power of graphics processing units (GPUs). In order to evaluate the parallelization strategies for the projection/backprojection pairs, an iterative image reconstruction algorithm is implemented. Computer simulation and experimental studies are conducted to investigate the computational efficiency and numerical accuracy of the developed algorithms. The GPU implementations improve the computational efficiency by factors of 1000, 125, and 250 for the FBP algorithm and the two pairs of projection/backprojection operators, respectively. Accurate images are reconstructed by use of the FBP and iterative image reconstruction algorithms from both computer-simulated and experimental data. Parallelization strategies for 3D OAT image reconstruction are proposed for the first time. These GPU-based implementations significantly reduce the computational time for 3D image reconstruction, complementing our earlier work on 3D OAT iterative image reconstruction.

  6. Iterative Reconstruction Methods for Hybrid Inverse Problems in Impedance Tomography

    DEFF Research Database (Denmark)

    Hoffmann, Kristoffer; Knudsen, Kim

    2014-01-01

    For a general formulation of hybrid inverse problems in impedance tomography the Picard and Newton iterative schemes are adapted and four iterative reconstruction algorithms are developed. The general problem formulation includes several existing hybrid imaging modalities such as current density...... impedance imaging, magnetic resonance electrical impedance tomography, and ultrasound modulated electrical impedance tomography, and the unified approach to the reconstruction problem encompasses several algorithms suggested in the literature. The four proposed algorithms are implemented numerically in two...... be based on a theoretical analysis of the underlying inverse problem....

  7. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Energy Technology Data Exchange (ETDEWEB)

    Razali, Azhani Mohd, E-mail: azhani@nuclearmalaysia.gov.my; Abdullah, Jaafar, E-mail: jaafar@nuclearmalaysia.gov.my [Plant Assessment Technology (PAT) Group, Industrial Technology Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang (Malaysia)

    2015-04-29

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  8. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Science.gov (United States)

    Razali, Azhani Mohd; Abdullah, Jaafar

    2015-04-01

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  9. [Role of cone-beam computed tomography in diagnostic otorhinolaryngological imaging].

    Science.gov (United States)

    Perényi, Ádám; Bella, Zsolt; Baráth, Zoltán; Magyar, Péter; Nagy, Katalin; Rovó, László

    2016-01-10

    Accurate diagnosis and preoperative planning in modern otorhinolaryngology is strongly supported by imaging with enhanced visualization. Computed tomography is often used to examine structures within bone frameworks. Given the hazards of ionizing radiation, repetitive imaging studies exponentially increase the risk of damages to radiosensitive tissues. The authors compare multislice and cone-beam computed tomography and determine the role, advantages and disadvantages of cone-beam computed tomography in otorhinolaryngological imaging. They summarize the knowledge from the international literature and their individual imaging studies. They conclude that cone-beam computed tomography enables high-resolution imaging and reconstruction in any optional plane and in space with considerably lower effective radiation dose. Cone-beam computed tomography with appropriate indications proved to be an excellent diagnostic tool in otorhinolaryngological imaging. It makes an alternative to multislice computed tomography and it is an effective tool in perioperative and postoperative follow-up, especially in those cases which necessitate repetitive imaging with computed tomography.

  10. Structure from Motion Photogrammetry and Micro X-Ray Computed Tomography 3-D Reconstruction Data Fusion for Non-Destructive Conservation Documentation of Lunar Samples

    Science.gov (United States)

    Beaulieu, K. R.; Blumenfeld, E. H.; Liddle, D. A.; Oshel, E. R.; Evans, C. A.; Zeigler, R. A.; Righter, K.; Hanna, R. D.; Ketcham, R. A.

    2017-01-01

    Our team is developing a modern, cross-disciplinary approach to documentation and preservation of astromaterials, specifically lunar and meteorite samples stored at the Johnson Space Center (JSC) Lunar Sample Laboratory Facility. Apollo Lunar Sample 60639, collected as part of rake sample 60610 during the 3rd Extra-Vehicular Activity of the Apollo 16 mission in 1972, served as the first NASA-preserved lunar sample to be examined by our team in the development of a novel approach to internal and external sample visualization. Apollo Sample 60639 is classified as a breccia with a glass-coated side and pristine mare basalt and anorthosite clasts. The aim was to accurately register a 3-dimensional Micro X-Ray Computed Tomography (XCT)-derived internal composition data set and a Structure-From-Motion (SFM) Photogrammetry-derived high-fidelity, textured external polygonal model of Apollo Sample 60639. The developed process provided the means for accurate, comprehensive, non-destructive visualization of NASA's heritage lunar samples. The data products, to be ultimately served via an end-user web interface, will allow researchers and the public to interact with the unique heritage samples, providing a platform to "slice through" a photo-realistic rendering of a sample to analyze both its external visual and internal composition simultaneously.

  11. Superfast maximum-likelihood reconstruction for quantum tomography

    Science.gov (United States)

    Shang, Jiangwei; Zhang, Zhengyun; Ng, Hui Khoon

    2017-06-01

    Conventional methods for computing maximum-likelihood estimators (MLE) often converge slowly in practical situations, leading to a search for simplifying methods that rely on additional assumptions for their validity. In this work, we provide a fast and reliable algorithm for maximum-likelihood reconstruction that avoids this slow convergence. Our method utilizes the state-of-the-art convex optimization scheme, an accelerated projected-gradient method, that allows one to accommodate the quantum nature of the problem in a different way than in the standard methods. We demonstrate the power of our approach by comparing its performance with other algorithms for n -qubit state tomography. In particular, an eight-qubit situation that purportedly took weeks of computation time in 2005 can now be completed in under a minute for a single set of data, with far higher accuracy than previously possible. This refutes the common claim that MLE reconstruction is slow and reduces the need for alternative methods that often come with difficult-to-verify assumptions. In fact, recent methods assuming Gaussian statistics or relying on compressed sensing ideas are demonstrably inapplicable for the situation under consideration here. Our algorithm can be applied to general optimization problems over the quantum state space; the philosophy of projected gradients can further be utilized for optimization contexts with general constraints.

  12. Computer-aided forensics: facial reconstruction.

    Science.gov (United States)

    Turner, Wesley; Tu, Peter; Kelliher, Timothy; Brown, Rebecca

    2006-01-01

    The 3D reconstruction of facial features from skeletal remains is a key component to the identification of missing persons and victims of violent crime. A comprehensive Computed Tomography (CT) head-scan database is currently being collected which will enable a new approach to forensic facial reconstruction. Using this unique resource, we show how a face space can be tailored to a specific unknown, or questioned skull. A set of database derived estimates of the questioned face is constructed by first computing non-rigid transformations between the known head-scan skulls and the questioned skull followed by application of these transformations to the known head-scan faces. This effectively factors out influences due to skeletal variation. A tailored face space is formed by applying Principal Component Analysis (PCA) to this ensemble of estimates of the questioned face. Thus, the face space is a direct approximation of correlated soft tissue variance indicative of the population. Ours is the first mathematical representation of the face continuum associated with a given skull. Embedded in this space resides the elements needed for recognition.

  13. Iterative reconstruction methods in atmospheric tomography: FEWHA, Kaczmarz and Gradient-based algorithm

    Science.gov (United States)

    Ramlau, R.; Saxenhuber, D.; Yudytskiy, M.

    2014-07-01

    The problem of atmospheric tomography arises in ground-based telescope imaging with adaptive optics (AO), where one aims to compensate in real-time for the rapidly changing optical distortions in the atmosphere. Many of these systems depend on a sufficient reconstruction of the turbulence profiles in order to obtain a good correction. Due to steadily growing telescope sizes, there is a strong increase in the computational load for atmospheric reconstruction with current methods, first and foremost the MVM. In this paper we present and compare three novel iterative reconstruction methods. The first iterative approach is the Finite Element- Wavelet Hybrid Algorithm (FEWHA), which combines wavelet-based techniques and conjugate gradient schemes to efficiently and accurately tackle the problem of atmospheric reconstruction. The method is extremely fast, highly flexible and yields superior quality. Another novel iterative reconstruction algorithm is the three step approach which decouples the problem in the reconstruction of the incoming wavefronts, the reconstruction of the turbulent layers (atmospheric tomography) and the computation of the best mirror correction (fitting step). For the atmospheric tomography problem within the three step approach, the Kaczmarz algorithm and the Gradient-based method have been developed. We present a detailed comparison of our reconstructors both in terms of quality and speed performance in the context of a Multi-Object Adaptive Optics (MOAO) system for the E-ELT setting on OCTOPUS, the ESO end-to-end simulation tool.

  14. Computed tomography of arachnoid cyst

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Min Gi; Bae, Weon Tae; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyun De [College of Medicine, Chonnam National University, Kwangju (Korea, Republic of)

    1988-02-15

    The preoperative diagnosis of intracranial arachnoid cysts has been simplified, and made more rapid and accurate with computed tomography (CT). Using CT cisternography, detailed anatomic and physiologic information of arachnoid cysts could be obtained. CT features of pathologically proven 21 arachnoid cysts that were examined at Chonnam National University Hospital from June 1983 to May 1987 were analyzed. The results were as follows: 1.Prevalent age group was the 1st decade (8 cases) and male to female ratio was 17:4. 2.Clinical features were related to the location of arachnoid cyst, common symptoms were headache (53.3%), convulsion, mental change and walking disturbance. 3.Location of the arachnoid cyst were in supratentorial region (15 cases) most in middle cranial fossa (12 cases), and infratentorial region (6 cases), common at the retrocerebellar cisternal space (3 cases). 4.Shapes of arachnoid cyst were biconvex with straight inner margin (8 cases), spherical (7 cases), simple biconvex (3 cases) and others (3 cases). 5.Size of the arachnoid cyst, in the greatest dimension, was ranged from 2cm to 9cm and commonly distributed between 3cm to 5cm (14 cases). 6.Of all 14 cases, who did CT cisternography using metrizamide (11 cases) and iopamidol (3 cases), 2 cases had communication with the subarachnoid space.

  15. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  16. 64层螺旋CT三维重建活体肝静脉的研究及临床意义%3D-reconstruction of hepatic vein by 64-Slice Spiral Computed Tomography and its significance

    Institute of Scientific and Technical Information of China (English)

    杨新文; 王剑华; 周庭永; 吕发金; 洪永华

    2009-01-01

    目的:探讨64层螺旋CT应用于正常人活体体肝静脉研究的可行性,观察三维重建肝静脉的一般形态及走行规律.方法:153例正常受试者经肘正中静脉注射造影剂后,使用64层螺旋CT进行上腹部扫描,图像采集后经容积再现(volume rendering,VR)技术重建肝静脉.结果:重建图像清晰,可显示出6~8级血管及与周围组织间的关系.其中153例肝静脉的分型结果如下:①3分支型,占35.3%(54例);②中左共干型,占41.8%(64例);③中左合干型,占20.9%(32例);④中右共干型,占2.0%(3例).结论:64层螺旋CT可以作为研究活体肝静脉形态的有效手段,三维重建能更准确、全方位地显示肝静脉的正常解剖类型和发现变异,而且图像清晰,对于活体肝静脉的研究有较好的临床应用价值.%Objective: To explore the feasibility of 64-Slice spiral computed tomography (CT) on reconstructing hepatic vein according to its morphology and distribution. Methods: After injecting contrast materials through median cubital vein, 153 voluneers underwent contrast-enhanced CT angiography of epigastric zone utilizing 64-Slice spiral computed tomography. Images were collected and dealt with the technique of volume rendering (VR),and then hepatic vein were reconstructed into 3D-images. Results: On reconstructed images, the vessels of the 6th and the 8th level, and their surrounding structures can be identified.According to the reconstruction images of 153 eases, hepatic.vein can be divided as follow types: ①Trifurcate type with the pencentage of 35.3% (54eases): left, middle and right hepatic veins drained into the inferior vena eava separately; ②Common trunk type of middle and left veins, 41.8% (64 cases): right hepatic vein drained into the inferior vena cava, however, left and middle hepatic veins confluened before their draining into the inferior vena cava; ③Common trunk type of left and right hepatic vein, 20.9% (32eases): left and middle

  17. Accelerating Image Reconstruction in Three-Dimensional Optoacoustic Tomography on Graphics Processing Units

    CERN Document Server

    Wang, Kun; Kao, Yu-Jiun; Chou, Cheng-Ying; Oraevsky, Alexander A; Anastasio, Mark A; 10.1118/1.4774361

    2013-01-01

    Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image reconstruction is computationally burdensome. The aim of this work is to accelerate existing image reconstruction algorithms for 3D OAT by use of parallel programming techniques. Methods: Parallelization strategies are proposed to accelerate a filtered backprojection (FBP) algorithm and two different pairs of projection/backprojection operations that correspond to two different numerical imaging models. The algorithms are designed to fully exploit the parallel computing power of graphic processing units (GPUs). In order to evaluate the parallelization strategies for the projection/backprojection pairs, an iterative image reconstruction algorithm is implemented. Computer-simulation and experimental studies are conducted to investigate the computational efficiency and numerical a...

  18. Assessment of asthmatic inflammation using hybrid fluorescence molecular tomography-x-ray computed tomography

    Science.gov (United States)

    Ma, Xiaopeng; Prakash, Jaya; Ruscitti, Francesca; Glasl, Sarah; Stellari, Fabio Franco; Villetti, Gino; Ntziachristos, Vasilis

    2016-01-01

    Nuclear imaging plays a critical role in asthma research but is limited in its readings of biology due to the short-lived signals of radio-isotopes. We employed hybrid fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) for the assessment of asthmatic inflammation based on resolving cathepsin activity and matrix metalloproteinase activity in dust mite, ragweed, and Aspergillus species-challenged mice. The reconstructed multimodal fluorescence distribution showed good correspondence with ex vivo cryosection images and histological images, confirming FMT-XCT as an interesting alternative for asthma research.

  19. Simultaneous maximum-likelihood reconstruction for x-ray grating based phase-contrast tomography avoiding intermediate phase retrieval

    CERN Document Server

    Ritter, André; Durst, Jürgen; Gödel, Karl; Haas, Wilhelm; Michel, Thilo; Rieger, Jens; Weber, Thomas; Wucherer, Lukas; Anton, Gisela

    2013-01-01

    Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction. For conventional x-ray computed tomography, the use of statistical iterative reconstruction algorithms has successfully reduced artifacts and statistical issues. In this work, an iterative reconstruction method for grating based phase-contrast tomography is presented. The method avoids the intermediate retrieval of absorption, differential phase and dark field projections. It directly reconstructs tomographic cross sections from phase stepping projections by the use of a forward projecting imaging model and an appropriate likelihood function. The likelihood function is then maximized with an iterative algorithm. The presented method is tested with tomographic data obtained through a wave field simulation of grating based phase-contrast tomography. The reconstruction result...

  20. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  1. Orbital computed tomography for exophthalmos

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan (Korea, Republic of)

    1987-06-15

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos.

  2. Efficacy of multislice computed tomography for gastroenteric and hepatic surgeries

    Institute of Scientific and Technical Information of China (English)

    Hiroshi Ohtani; Mitsuo Tsubakimoto; Hidemi Kawajiri; Yuichi Arimoto; Koichi Ohno; Yasuhisa Fujimoto; Hiroko Oba; Kenji Adachi; Masaya Hirano; Shoichi Terakawa

    2005-01-01

    AIM: To determine the efficacy of multislice CT for gastroenteric and hepatic surgery.METHODS: Dual-phase helical computed tomography was performed in 50 of 51 patients who underwent gastroenteric and hepatic surgeries. Twenty-eight, eighteen and four patients suffering from colorectal cancer, gastric cancer,and liver cancer respectively underwent colorectal surgery (laparoscopic surgery: 6 cases), gastrectomy, and hepatectomy. Three-dimensional computed tomography imaging of the inferior mesenteric artery, celiac artery and hepatic artery was performed. And in the follow-up examination of postoperative patients, multiplanar reconstruction image was made in case of need.RESULTS: Scans in 50 patients were technically satisfactory and included in the analysis. Depiction of major visceral arteries, which were important for surgery and other treatments, could be done in all patients.Preoperative visualization of the left colic artery and sigmoidal arteries, the celiac artery and its branches, and hepatic artery was very useful to lymph node dissection,the planning of a reservoir and hepatectomy. And multiplanar reconstruction image was helpful to diagnosis for the postoperative follow-up of patients.CONCLUSION: Three-dimensional volume rendering or multiplanar reconstruction imaging performed by multislice computed tomography was very useful for gastroenteric and hepatic surgeries.

  3. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  4. Flame four-dimensional deflection tomography with compressed-sensing-revision reconstruction

    Science.gov (United States)

    Zhang, Bin; Zhao, Minmin; Liu, Zhigang; Wu, Zhaohang

    2016-08-01

    Deflection tomography with limited angle projections was investigated to visualize a premixed flame. A projection sampling system for deflection tomography was used to obtain chronological deflectogram arrays at six view angles with only a pair of gratings. A new iterative reconstruction algorithm with deflection angle compressed-sensing revision was developed to improve reconstruction-distribution quality from incomplete projection data. Numerical simulation and error analysis provided a good indication of algorithm precision and convergence. In the experiment, 150 fringes were processed, and temperature distributions in 20 cross-sections were reconstructed from projection data in four instants. Four-dimensional flame structures and temperature distributions in the flame interior were visualized using the visualization toolkit. The experimental reconstruction was then compared with the result obtained from computational fluid dynamic analysis.

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... materials and a metallic taste in his/her mouth that lasts for a few minutes. Occasionally, a ...

  6. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    Mcevoy, Fintan J; Buelund, Lene; Strathe, Anders B

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  7. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  8. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  9. Single photon emission computed tomography/computed tomography of the skull in malignant otitis externa.

    Science.gov (United States)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Kamaleshwaran, Koramadai Karuppusamy; Agrawal, Kanhaiyalal; Gupta, Ashok Kumar; Mittal, Bhagwant Rai

    2012-01-01

    Malignant otitis externa is a severe, rare infective condition of the external auditory canal and skull base. The diagnosis is generally made from a range of clinical, laboratory, and imaging findings. Technetium 99m methylene diphosphonate bone scintigraphy is known to detect osteomyelitis earlier than computed tomography. The authors present a patient with bilateral malignant otitis externa where the extent of skull base involvement was determined on 3-phase bone scintigraphy with single photon emission computed tomography/computed tomography.

  10. WE-G-207-03: Mask Guided Image Reconstruction (MGIR): A Novel Method for Ultra-Low-Dose 3D and Enhanced 4D Cone-Beam Computer-Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, C; Zhang, H; Chen, Y; Fan, Q; Kahler, D; Li, J; Liu, C; Lu, B [Univ Florida, Gainesville, FL (United States)

    2015-06-15

    Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of images alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on

  11. Mitigating artifacts via half-time reconstruction in thermoacoustic tomography

    Science.gov (United States)

    Anastasio, Mark A.; Zhang, Jin; Pan, Xiaochuan; Ku, Geng; Wang, Lihong V.

    2005-04-01

    Thermoacoustic tomography (TAT) is an ultrasound-mediated biophotonic imaging modality with great potential for a wide range of biomedical imaging applications. In this work, we demonstrate that half-time reconstruction approaches for TAT can mitigate image artifacts due to heterogeneous acoustic properties of an object. We also discuss how half-time reconstruction approaches permit explicit control of statistically complementary information in the measurement data, which can facilitate the reduction of image variances.

  12. Computed tomography using broadband Bessel THz beams and phase contrast.

    Science.gov (United States)

    Bitman, Assaf; Goldring, Sharone; Moshe, Inon; Zalevsky, Zeev

    2014-04-01

    We present new results demonstrating the capability of performing computed tomography (CT) using broadband Bessel terahertz (THz) beams. Nondiffractive beams such as these exhibit propagation-invariant lines of focus with an extended depth-of-field compared to conventional Gaussian beams. Using this property, we demonstrate a considerable improvement in the 3D reconstruction image of a synthetic sample through the backprojection algorithm. Only when THz Bessel beams are used, a full reconstruction of the object structure is made. Moreover, we use phase-contrast mechanism which improves the spatial resolution and reconstructed images. Our results highlight the potential in using nondiffractive Bessel beams to significantly improve 3D-image reconstruction of THz CT.

  13. Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients

    Energy Technology Data Exchange (ETDEWEB)

    Pontana, Francois; Pagniez, Julien; Faivre, Jean-Baptiste; Hachulla, Anne-Lise; Remy, Jacques [University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain [University Lille Nord de France, Department of Medical Statistics, Lille (France); Flohr, Thomas [Computed Tomography Division, Siemens Healthcare, Forchheim (Germany); Remy-Jardin, Martine [University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Hospital Calmette, Department of Thoracic Imaging, Lille cedex (France)

    2011-03-15

    To evaluate the image quality of an iterative reconstruction algorithm (IRIS) in low-dose chest CT in comparison with standard-dose filtered back projection (FBP) CT. Eighty consecutive patients referred for a follow-up chest CT examination of the chest, underwent a low-dose CT examination (Group 2) in similar technical conditions to those of the initial examination, (Group 1) except for the milliamperage selection and the replacement of regular FBP reconstruction by iterative reconstructions using three (Group 2a) and five iterations (Group 2b). Despite a mean decrease of 35.5% in the dose-length-product, there was no statistically significant difference between Group 2a and Group 1 in the objective noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and distribution of the overall image quality scores. Compared to Group 1, objective image noise in Group 2b was significantly reduced with increased SNR and CNR and a trend towards improved image quality. Iterative reconstructions using three iterations provide similar image quality compared with the conventionally used FBP reconstruction at 35% less dose, thus enabling dose reduction without loss of diagnostic information. According to our preliminary results, even higher dose reductions than 35% may be feasible by using more than three iterations. (orig.)

  14. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  15. Optimization of Anteromedial Portal Femoral Tunnel Drilling With Flexible and Straight Reamers in Anterior Cruciate Ligament Reconstruction: A Cadaveric 3-Dimensional Computed Tomography Analysis.

    Science.gov (United States)

    Forsythe, Brian; Collins, Michael J; Arns, Thomas A; Zuke, William A; Khair, Michael; Verma, Nikhil N; Cole, Brian J; Bach, Bernard R; Inoue, Nozomu

    2017-05-01

    To use 3-dimensional custom CAD technology to evaluate how knee flexion angle affects femoral tunnel length and distance to the posterior wall when using curved and straight guides for drilling through the anteromedial portal (AMP). Six cadaveric knees were placed in an external fixator at various degrees of flexion (90°, 110°, 125°, and maximum 135° to 140°). Computed tomography scans were obtained at all flexion points for 3-dimensional point-cloud models. Using custom CAD software, surgical guides through the AMP were replicated along with virtual tunnels at each flexion angle. Distance from the posterior cortex and tunnel dimensions were collected after 8-mm and 10-mm tunnel creation. At 90° of flexion, the average tunnel length down the posterior aspect of 8-mm tunnel was 25.0 mm (95% confidence interval [CI] 16.2-33.8) and 12.0 mm (95% CI 7.3-16.7) for curved and straight guides, respectively; 31.0 mm (95% CI 26.8-35.2) and 28.6 mm (95% CI 24.8-32.4) at 110°; 33.8 mm (95% CI 30.1-37.5) and 31.1 mm (95% CI 26.8-35.4) at 125°; and 35.0 mm (95% CI 34.1-35.9) and 35.5 mm (95% CI 34.2-36.8) with maximal flexion. Values between curved and straight guides are significantly different (P < .001), with straight guides breaching the posterior wall at 90° and 110° of flexion in some specimens. The average distance to the posterior wall cortex was 0.9 mm (95% CI -1.5 to 3.3) and -0.6 mm (95% CI -2.3 to 1.1) for curved and straight guides, respectively, at 90° of flexion (P = .014); 2.3 mm (95% CI -0.2 to 4.8) and -0.1 mm (95% CI -2.4 to 2.2) at 110° (P = .001); 4.4 mm (95% CI 2.8-6.0) and 3.9 mm (95% CI 1.9-5.9) at 125° (P = .299); and 6.7 mm (95% CI 6.2-7.2) and 8.3 mm (95% CI 6.1-10.5) at maximal flexion (P = .184). Posterior wall blowout was noted when using 10-mm straight guides at both 90° (2 specimens) and 110° (3 specimens). Using 10-mm curved guides posterior blowout was noted in 1 specimen at 90°. Maximum footprint

  16. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  17. Application of computed tomography in paleoanthropological research

    Institute of Scientific and Technical Information of China (English)

    Xiujie Wu; Lynne A.Schepartz

    2009-01-01

    Hominin fossils are the most important materials for exploring questions about human origins and evolution. Because human fossils are very rare, it is impossible to use highly destructive techniques in order to study their morphology. Traditional analyses can only rely on the information gained from the study of the external morphology of specimens, and these approaches limited the study of human evolution. The application of computed tomography (CT) has facilitated major developments in paleoanthropology. To date, few studies on Chinese hominin fossils have used CT scanning methodology, but this is rapidly changing. In order to better understand the appli-cation of CT methodology in paleoanthropology, we review the applications of CT scanning on hominin fossils throughout the world.Studies examined include virtual fossil reconstruction, the use of endocasts to elucidate brain morphology, biomechanical analyses of bone distribution, imaging of mummies and research on early human health, and skeletal and dental microanatomical research.2009 National Natural Science Foundation of China and Chinese Academy of Sciences. Published by Elsevier Limited and Science in China Press. All rights reserved.

  18. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  19. REVIEW: X-ray computed tomography

    Science.gov (United States)

    Kalender, Willi A.

    2006-07-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.

  20. A Detector for Proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blazey, G.; et al.

    2013-12-06

    Radiation therapy is a widely recognized treatment for cancer. Energetic protons have distinct features that set them apart from photons and make them desirable for cancer therapy as well as medical imaging. The clinical interest in heavy ion therapy is due to the fact that ions deposit almost all of their energy in a sharp peak – the Bragg peak- at the very end of their path. Proton beams can be used to precisely localize a tumor and deliver an exact dose to the tumor with small doses to the surrounding tissue. Proton computed tomography (pCT) provides direct information on the location on the target tumor, and avoids position uncertainty caused by treatment planning based on imaging with X-ray CT. The pCT project goal is to measure and reconstruct the proton relative stopping power distribution directly in situ. To ensure the full advantage of cancer treatment with 200 MeV proton beams, pCT must be realized.

  1. Three-dimensional localization of implanted biomaterials in anatomical and histological specimens using combined X-ray computed tomography and three-dimensional surface reconstruction: a technical note.

    NARCIS (Netherlands)

    Cuijpers, V.M.J.I.; Walboomers, X.F.; Jansen, J.A.

    2010-01-01

    For adequate histological processing of implanted biomaterials or tissue-engineered constructs, it is sometimes essential to obtain insight into the localization of structures inside the tissue samples. Observation of three-dimensional (3D) surface reconstruction, including basic photorealistic text

  2. Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Motoo; Ozawa, Yoshiyuki; Sakurai, Keita; Shimohira, Masashi; Shibamoto, Yuta [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, Nagoya (Japan); Ohashi, Kazuya [Nagoya City University Hospital, Division of Central Radiology, Nagoya (Japan); Asano, Miki [Nagoya City University Graduate School of Medical Sciences, Department of Cardiovascular Surgery, Nagoya (Japan); Yamaguchi, Sachiko [Nagoya City University Graduate School of Medical Sciences, Department of Pediatrics and Neonatology, Nagoya (Japan)

    2015-09-15

    Lower tube voltage has advantages for CT angiography, such as improved contrast To evaluate the image quality of low-voltage (70 kV) CT for congenital heart disease and the ability of sinogram-affirmed iterative reconstruction to improve image quality. Forty-six children with congenital heart disease (median age: 109 days) were examined using dual-source CT. Scans were performed at 80 kV and 70 kV in 21 and 25 children, respectively. A nonionic iodinated contrast medium (300 mg I/ml) was used for the 80-kV protocol. The contrast medium was diluted to 75% (225 mgI/mL) with saline for the 70-kV protocol. Image noise was measured in the two protocols for each group by extracting the standard deviations of a region of interest placed on the descending aorta. We then determined whether sinogram-affirmed iterative reconstruction reduced the image noise at 70 kV. There was more noise at 70 kV than at 80 kV (29 ± 12 vs 20 ± 4.8; P < 0.01). Sinogram-affirmed iterative reconstruction with grade 4 strength settings improved the noise (20 ± 5.9; P < 0.01) for the 70-kV group. Sinogram-affirmed iterative reconstruction improved the image quality of CT in congenital heart disease. (orig.)

  3. Three Dimensional Iterative Reconstruction Techniques in Positron Tomography.

    Science.gov (United States)

    Sloka, Scott

    The acquisition of positron tomographic data in three dimensions is an improvement over the two dimensional acquisition of data because the greater the number of measurements taken of a stochastic process, the more accurately determined the desired parameter may be. This research pursues the goal of three dimensional image reconstruction in Positron Tomography using an iterative approach. This thesis has followed a systematic approach to the exploration of a system for three dimensional iterative reconstruction. System design parameters were discussed such as the advantages and disadvantages of iterative vs analytic methods, the implementation of two, three dimensional iterative algorithms, the selection of a ray passing method, and the choice of an analytic method for comparison to the iterative methods. Several qualitative and quantitative tests were used/developed and performed to analyse and compare the results. Three dimensional reconstruction in Positron Tomography using two iterative techniques (ART and ML-EM) was demonstrated. The ML-EM algorithm was adapted to satisfy the objective of equalizing the estimates with the measurements via division of the sampling density. A new multi-objective function methodology was developed for two dimensions and its extension to three dimensions discussed. A smoothly-varying Gaussian phantom was created for comparing artifacts from different ray passing methods. The analysis of voxel trends over many iterations was used. The use of the output from a two dimensional filtered backprojection algorithm as the seed for three dimensional algorithms to accelerate the reconstruction the was explored. The importance of the selection of a good ray ordering in ART and its effects on the total squared error were explored. For the phantoms studied in this thesis, the ML -EM algorithm tended to perform better under most conditions. This algorithm is slower than ART to achieve both a low total squared error and good contrast, but the

  4. Reduction of metal artifacts due to dental hardware in computed tomography angiography: assessment of the utility of model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kuya, Keita; Shinohara, Yuki; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Kato, Ayumi [Tottori Municipal Hospital, Department of Radiology, Yonago (Japan); Sakamoto, Makoto; Kurosaki, Masamichi [Tottori University, Division of Neurosurgery, Department of Neurological Sciences, Faculty of Medicine, Yonago (Japan)

    2017-03-15

    The aim of this study is to assess the value of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) for reduction of metal artifacts due to dental hardware in carotid CT angiography (CTA). Thirty-seven patients with dental hardware who underwent carotid CTA were included. CTA was performed with a GE Discovery CT750 HD scanner and reconstructed with filtered back projection (FBP), ASIR, and MBIR. We measured the standard deviation at the cervical segment of the internal carotid artery that was affected most by dental metal artifacts (SD{sub 1}) and the standard deviation at the common carotid artery that was not affected by the artifact (SD{sub 2}). We calculated the artifact index (AI) as follows: AI = [(SD{sub 1})2 - (SD{sub 2})2]1/2 and compared each AI for FBP, ASIR, and MBIR. Visual assessment of the internal carotid artery was also performed by two neuroradiologists using a five-point scale for each axial and reconstructed sagittal image. The inter-observer agreement was analyzed using weighted kappa analysis. MBIR significantly improved AI compared with FBP and ASIR (p < 0.001, each). We found no significant difference in AI between FBP and ASIR (p = 0.502). The visual score of MBIR was significantly better than those of FBP and ASIR (p < 0.001, each), whereas the scores of ASIR were the same as those of FBP. Kappa values indicated good inter-observer agreements in all reconstructed images (0.747-0.778). MBIR resulted in a significant reduction in artifact from dental hardware in carotid CTA. (orig.)

  5. Regularized Image Reconstruction for Ultrasound Attenuation Transmission Tomography

    Directory of Open Access Journals (Sweden)

    I. Peterlik

    2008-06-01

    Full Text Available The paper is focused on ultrasonic transmission tomography as a potential medical imaging modality, namely for breast cancer diagnosis. Ultrasound attenuation coefficient is one of the tissue parameters which are related to the pathological tissue state. A technique to reconstruct images of attenuation distribution is presented. Furthermore, an alternative to the commonly used filtered backprojection or algebraic reconstruction techniques is proposed. It is based on regularization of the image reconstruction problem which imposes smoothness in the resulting images while preserving edges. The approach is analyzed on synthetic data sets. The results show that it stabilizes the image restoration by compensating for main sources of estimation errors in this imaging modality.

  6. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  7. A Rotative Electrical Impedance Tomography Reconstruction System

    Energy Technology Data Exchange (ETDEWEB)

    Yu, F-M [St. John' s and St. Mary' s Institute of Technology, Department of computer science and information Engineering, 499, Sec. 4, Tam King Road Tamsui, Taipei, Taiwan (China); Huang, C-N [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China); Chang, F-W [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China); Chung, H-Y [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China)

    2006-10-15

    Electrical impedance tomography (EIT) is a powerful tool for mapping the conductivity distribution of estimated objects. The EIT system is entirely implemented by electrical technique, so it is a relatively cheap system and data can be collected very rapidly. But it has few commercially medical EIT systems available. This is because impedance image unable to achieve the essential spatial resolution and this technique has an intrinsically poor signal to noise ratio. In this paper, we have developed a high performance rotative EIT system (REIT) for expanding the independent measurements. By rotate the electrodes successive, REIT could change the position of electrodes and acquire more measurement data. This rotative measurement method not only can increase the resolution of impedance images, but also reduce the complexity of measurement system. We hope the improvement of REIT will bring some help in electrical impedance tomography.

  8. Volumetric analysis of lung nodules in computed tomography (CT): comparison of two different segmentation algorithm softwares and two different reconstruction filters on automated volume calculation.

    Science.gov (United States)

    Christe, Andreas; Brönnimann, Alain; Vock, Peter

    2014-02-01

    A precise detection of volume change allows for better estimating the biological behavior of the lung nodules. Postprocessing tools with automated detection, segmentation, and volumetric analysis of lung nodules may expedite radiological processes and give additional confidence to the radiologists. To compare two different postprocessing software algorithms (LMS Lung, Median Technologies; LungCARE®, Siemens) in CT volumetric measurement and to analyze the effect of soft (B30) and hard reconstruction filter (B70) on automated volume measurement. Between January 2010 and April 2010, 45 patients with a total of 113 pulmonary nodules were included. The CT exam was performed on a 64-row multidetector CT scanner (Somatom Sensation, Siemens, Erlangen, Germany) with the following parameters: collimation, 24x1.2 mm; pitch, 1.15; voltage, 120 kVp; reference tube current-time, 100 mAs. Automated volumetric measurement of each lung nodule was performed with the two different postprocessing algorithms based on two reconstruction filters (B30 and B70). The average relative volume measurement difference (VME%) and the limits of agreement between two methods were used for comparison. At soft reconstruction filters the LMS system produced mean nodule volumes that were 34.1% (P filters (B30) was significantly larger than with hard filters (B70); 11.2% for LMS and 1.6% for LungCARE®, respectively (both with P filters, 13.6% for soft and 3.8% for hard filters, respectively (P  0.05). There is a substantial inter-software (LMS/LungCARE®) as well as intra-software variability (B30/B70) in lung nodule volume measurement; therefore, it is mandatory to use the same equipment with the same reconstruction filter for the follow-up of lung nodule volume.

  9. Measurement of bone mineral density in the tunnel regions for anterior cruciate ligament reconstruction by dual-energy X-ray absorptiometry, computed tomography scan, and the immersion technique based on Archimedes' principle.

    Science.gov (United States)

    Tie, Kai; Wang, Hua; Wang, Xin; Chen, Liaobin

    2012-10-01

    To determine, for anterior cruciate ligament (ACL) reconstruction, whether the bone mineral density (BMD) of the femoral tunnel was higher than that of the tibial tunnel, to provide objective evidence for choosing the appropriate diameter of interference screws. Two groups were enrolled. One group comprised 30 normal volunteers, and the other comprised 9 patients with ACL rupture. Dual-energy X-ray absorptiometry was used to measure the BMD of the femoral and tibial tunnel regions of the volunteers' right knees by choosing a circular area covering the screw fixation region. The knees were also scanned by spiral computed tomography (CT), and the 3-dimensional reconstruction technique was used to determine the circular sections passing through the longitudinal axis of the femoral and tibial tunnels. Grayscale CT values of the cross-sectional area were measured. Cylindrical cancellous bone blocks were removed from the femoral and tibial tunnels during the ACL reconstruction for the patients. The volumetric BMD of the bone blocks was measured using a standardized immersion technique according to Archimedes' principle. As measured by dual-energy X-ray absorptiometry, the BMD of the femoral and tibial tunnel regions was 1.162 ± 0.034 g/cm(2) and 0.814 ± 0.038 g/cm(2), respectively (P < .01). The CT value of the femoral tunnel region was 211.7 ± 11.5 Hounsfield units, and the value of the tibial tunnel region was 104.9 ± 7.4 Hounsfield units (P < .01). The volumetric BMD of the bone block from the femoral tunnel (2.80 ± 0.88 g/cm(3)) was higher than the value from the tibial tunnel (1.88 ± 0.59 g/cm(3)) (P < .01). Comparing the data between male and female patients, we found no significant difference in both femoral and tibial tunnel regions. For ACL reconstruction, the BMD of the femoral tunnel is higher than that of the tibial tunnel. This implies that a proportionally larger-diameter interference screw should be used for fixation in the proximal tibia than that

  10. 太赫兹计算机辅助层析图像重构算法仿真研究%Simulation on THz computed tomography image reconstruction methods

    Institute of Scientific and Technical Information of China (English)

    李运达; 李琦; 刘正君; 王骐

    2013-01-01

      由于太赫兹波具有独特的性质,使得太赫兹成像技术成为目前的研究热点。太赫兹层析成像可以获得物体横截面的分布信息并可获得物体的三维重构图像,因此也受到了广泛关注。文中对连续太赫兹层析成像进行了仿真研究。分别使用滤波反投影算法(FBP)和改进的联合代数重建算法(MSART)进行图像重构,并且分析比较了高斯低通滤波(GLPF)以及数学形态学等数字图像处理方法对改善重构图像质量的效果。仿真结果表明:在文中的仿真条件下,使用MSART算法及相应的图像处理方法所需的最少投影方向数可以达到9,与真实成像实验结果相吻合。%  Terahertz (THz) radiation has many particular characteristics, which make THz image technology become the hot research area. As the distribution information of the cross section and the 3D reconstruction image of a sample can be obtained, THz computed tomography (CT) also attracts wide extensive attention worldwide. The simulation research was done based on continuous THz CT. The filtered back-projection (FBP) method and the modified simultaneous algebraic reconstruction technique (MSART) method have been utilized to reconstruct cross-section images, and the efficiency of the image processing operations such as the Gaussian low-pass filter (GLPF) and the morphological functions in mathematical morphology like open operation and close operation in improving reconstruction image quality has been compared and analyzed. It can be inferred from the simulation results that the required number of the projection directions using the MSART method and the corresponding image processing operations can only be 9, which is inosculate to the real imaging experiment results.

  11. Simulation of Computed Tomography Reconstruction Algorithm Based on Consecutive X -ray Spectrum%基于连续X射线谱的CT重建算法仿真

    Institute of Scientific and Technical Information of China (English)

    蔡彪; 潘晋孝; 陈平

    2011-01-01

    Traditional reconstruction algorithms assume that the X - ray is monochromatic, while in fact, X - ray is polychromatic in actual CT. When the polychromatic projection data are used to reconstruct the images directly,metal artifacts and beam - hardening artifacts appear in the reconstructed images, which reduces image quality and affects medical or industrial diagnosis. This paper considers the consecution of X - ray spectrum, and simulats the statistical reconstruction algorithm based on consecutive X - ray spectrum. Firstly, consecutive spectrum was discretized as monochromatic spectrum. Secondly, according to the workpiece material information and mass attenuation coefficient corresponding to X - ray energy, the workpiece material model was formulated based on consecutive spectrum. Finally, using the polychromatic - energy statistics iterate algorithm, the reconstruction was caried out based on polychromatic projection data. Through the simulation experiment, the algorithm reduces the artifacts to a certain extent, and improves the image quality.%关于提高CT图像精度的问题,传统的CT重建算法都是基于X射线源是单色源的假设,忽略了X射线的多色性.直接用多色投影数据进行图像重建易产生金属、硬化等伪影,降低图像质量,影响CT值标定,从而影响医学或工业诊断.考虑到X射线能谱的连续性,采用仿真手段实现连续X射线谱的统计重建.首先将连续X射线谱离散成若干单能谱,再根据待检工件的材质信息以及射线能量所对应的质量衰减系数,构建基于连续X射线谱的工件材质模型;最后利用多能统计重建算法对多能投影数据进行迭代重建.仿真结果表明,算法充分地利用了X射线的多能性,在一定程度上可以有效地降低图像伪影,提高CT重建图像质量.

  12. Geometric reconstruction methods for electron tomography

    DEFF Research Database (Denmark)

    Alpers, Andreas; Gardner, Richard J.; König, Stefan

    2013-01-01

    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts...... and non-linear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full 180° tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce...

  13. Impact of a 4th generation iterative reconstruction technique on image quality in low-dose computed tomography of the chest in immunocompromised patients

    Energy Technology Data Exchange (ETDEWEB)

    Laqmani, A.; Hennes, F.O.; Klink, T.; Schultzendorff, H.C. von; Hammerle, D.; Adam, G.; Regier, M. [Univ. Medical Center, Hamburg-Eppendorf (Germany). Dept. of Diagnostic and Interventional Radiology; Buhk, J.H. [Univ. Medical Center, Hamburg-Eppendorf (Germany). Dept. of Diagnostic and Interventional Neuroradiology; Sehner, S. [Univ. Medical Center, Hamburg-Eppendorf (Germany). Dept. of Medical Biometry and Epidemiology; Nagel, H.D. [Dr. HD Nagel, Science and Technology for Radiology, Buchholz (Germany)

    2013-08-15

    Purpose: To determine the image quality of an iterative reconstruction (IR) technique in low-dose MDCT (LDCT) of the chest of immunocompromised patients in an intraindividual comparison to filtered back projection (FBP) and to evaluate the dose reduction capability. Materials and Methods: 30 chest LDCT scans were performed in immunocompromised patients (Brilliance iCT; 20 - 40 mAs; mean CTDIvol: 1.7 mGy). The raw data were reconstructed using FBP and the IR technique (iDose4 trademark, Philips, Best, The Netherlands) set to seven iteration levels. 30 routine-dose MDCT (RDCT) reconstructed with FBP served as controls (mean exposure: 116 mAs; mean CDTIvol: 7.6 mGy). Three blinded radiologists scored subjective image quality and lesion conspicuity. Quantitative parameters including CT attenuation and objective image noise (OIN) were determined. Results: In LDCT high iDose4 trademark levels lead to a significant decrease in OIN (FBP vs. iDose7: subscapular muscle 139.4 vs. 40.6 HU). The high iDose4 trademark levels provided significant improvements in image quality and artifact and noise reduction compared to LDCT FBP images. The conspicuity of subtle lesions was limited in LDCT FBP images. It significantly improved with high iDose4 trademark levels (> iDose4). LDCT with iDose4 trademark level 6 was determined to be of equivalent image quality as RDCT with FBP. Conclusion: iDose4 trademark substantially improves image quality and lesion conspicuity and reduces noise in low-dose chest CT. Compared to RDCT, high iDose4 trademark levels provide equivalent image quality in LDCT, hence suggesting a potential dose reduction of almost 80%. (orig.)

  14. Attenuation correction for X-ray emission computed tomography of laser-produced plasma

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yen-Wei; Nakao, Zensho [Ryukyus Univ., Nishihara, Okinawa (Japan). Faculty of Engineering; Tamura, Shinichi

    1996-08-01

    An attenuation correction method was proposed for laser-produced plasma emission computed tomography (ECT), which is based on a relation of the attenuation coefficient and the emission coefficient in plasma. Simulation results show that the reconstructed images are dramatically improved in comparison to the reconstructions without attenuation correction. (J.P.N.)

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  17. A nonlinear fuzzy assisted image reconstruction algorithm for electrical capacitance tomography.

    Science.gov (United States)

    Deabes, W A; Abdelrahman, M A

    2010-01-01

    A nonlinear method based on a Fuzzy Inference System (FIS) to improve the images obtained from Electrical Capacitance Tomography (ECT) is proposed. Estimation of the molten metal characteristic in the Lost Foam Casting (LFC) process is a novel application in the area of the tomography process. The convergence rate of iterative image reconstruction techniques is dependent on the accuracy of the first image. The possibility of the existence of metal in the first image is computed by the proposed fuzzy system. This first image is passed to an iterative image reconstruction technique to get more precise images and to speed up the convergence rate. The proposed technique is able to detect the position of the metal on the periphery of the imaging area by using just eight capacitive sensors. The final results demonstrate the advantage of using the FIS compared to the performance of the iterative back projection image reconstruction technique.

  18. Reconstruction and visualization of nanoparticle composites by transmission electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.Y. [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Canada T6G 2G7 (Canada); Lockwood, R. [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada); Malac, M., E-mail: marek.malac@nrc-cnrc.gc.ca [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Canada T6G 2G7 (Canada); Furukawa, H. [SYSTEM IN FRONTIER INC., 2-8-3, Shinsuzuharu bldg. 4F, Akebono-cho, Tachikawa-shi, Tokyo 190-0012 (Japan); Li, P.; Meldrum, A. [National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton, Canada T6H 2M9 (Canada)

    2012-02-15

    This paper examines the limits of transmission electron tomography reconstruction methods for a nanocomposite object composed of many closely packed nanoparticles. Two commonly used reconstruction methods in TEM tomography were examined and compared, and the sources of various artefacts were explored. Common visualization methods were investigated, and the resulting 'interpretation artefacts' ( i.e., deviations from 'actual' particle sizes and shapes arising from the visualization) were determined. Setting a known or estimated nanoparticle volume fraction as a criterion for thresholding does not in fact give a good visualization. Unexpected effects associated with common built-in image filtering methods were also found. Ultimately, this work set out to establish the common problems and pitfalls associated with electron beam tomographic reconstruction and visualization of samples consisting of closely spaced nanoparticles. -- Highlights: Black-Right-Pointing-Pointer Electron tomography limits were explored by both experiment and simulation. Black-Right-Pointing-Pointer Reliable quantitative volumetry using electron tomography is not presently feasible. Black-Right-Pointing-Pointer Volume rendering appears to be better choice for visualization of composite samples.

  19. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen, E-mail: zhengmw2007@163.com; Liu, Ying, E-mail: yingyinglyly@126.com; Wei, Mengqi, E-mail: weimengqi2008@163.com; Wu, Yongjie, E-mail: wu18291988526@163.com; Zhao, Hongliang, E-mail: zhaohl1980@163.com; Li, Jian, E-mail: xjyylj@yeah.net

    2014-02-15

    Objectives: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality and radiation dose of coronary CT angiography (cCTA) by using a combination of iterative reconstruction (IR) and low-tube-voltage technique. Materials and methods: One hundred patients were prospectively randomized to two types of contrast medium and underwent prospective electrocardiogram-triggering cCTA (Definition Flash, Siemens Healthcare; collimation: 128 mm × 0.6 mm; tube current: 300 mA s). Fifty patients received Iopromide 370 were scanned using the conventional tube setting (100 kVp or 120 kVp if BMI ≥ 25 kg/m{sup 2}) and reconstructed with filtered back projection (FBP). Fifty patients received Iodixanol 270 were scanned using the low-tube-voltage (80 kVp or 100 kVp if BMI ≥ 25 kg/m{sup 2}) technique and reconstructed with IR. CT attenuation was measured in coronary artery and other anatomical regions. Noise, image quality and radiation dose were compared. Results: Compared with two Iopromide 370 subgroups, Iomeprol 270 subgroups showed no significant difference in CT attenuation (576.63 ± 95.50 vs. 569.51 ± 118.93 for BMI < 25 kg/m{sup 2}, p = 0.647 and 394.19 ± 68.09 vs. 383.72 ± 63.11 for BMI ≥ 25 kg/m{sup 2}, p = 0.212), noise (in various anatomical regions of interest) and image quality (3.5 vs. 4.0, p = 0.13), but significantly (0.41 ± 0.17 vs. 0.94 ± 0.45 for BMI < 25 kg/m{sup 2}, p < 0.001 and 1.14 ± 0.24 vs. 2.37 ± 0.69 for BMI ≥ 25 kg/m{sup 2}, p < 0.001) lower radiation dose, which reflects dose saving of 56.4% and 51.9%, respectively. Conclusions: Combined IR with low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/ml can still maintain the contrast enhancement without impairing image quality, as well as significantly lower the radiation dose.

  20. 3D Reconstruction and Virtual Cutting Research on Coarse Aggregate Morphology and the MicroFabric with Computed Tomography and the Visualization Toolkit

    Directory of Open Access Journals (Sweden)

    Zhiyuan Zeng

    2012-08-01

    Full Text Available Three-dimensional visualization is a new research field in information processing and VTK is a visualization toolkit with strong functions. Due to the fact that most two-dimensional microfabric models of coarse-aggregate materials are not accurate, three-dimensional model is needed. This study laid its focus on the theoretical model of three-dimensional visualization and the visualization technology based on VTK to study the coarse-aggregate morphology and the microfabric. The experimental reconstruction results show that the particle morphology and inter-particle pore space are clear and can describe the morphological features of coarse-aggregate particle accurately with the assistance of suitable virtual cutting method.

  1. A combined reconstruction algorithm for computerized ionospheric tomography

    Science.gov (United States)

    Wen, D. B.; Ou, J. K.; Yuan, Y. B.

    Ionospheric electron density profiles inverted by tomographic reconstruction of GPS derived total electron content TEC measurements has the potential to become a tool to quantify ionospheric variability and investigate ionospheric dynamics The problem of reconstructing ionospheric electron density from GPS receiver to satellite TEC measurements are formulated as an ill-posed discrete linear inverse problem A combined reconstruction algorithm of computerized ionospheric tomography CIT is proposed in this paper In this algorithm Tikhonov regularization theory TRT is exploited to solve the ill-posed problem and its estimate from GPS observation data is input as the initial guess of simultaneous iterative reconstruction algorithm SIRT The combined algorithm offer a more reasonable method to choose initial guess of SIRT and the use of SIRT algorithm is to improve the quality of the final reconstructed imaging Numerical experiments from the actual GPS observation data are used to validate the reliability of the method the reconstructed results show that the new algorithm works reasonably and effectively with CIT the overall reconstruction error reduces significantly compared to the reconstruction error of SIRT only or TRT only

  2. Weighted simultaneous iterative reconstruction technique for single-axis tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, D., E-mail: Daniel.Wolf@Triebenberg.de; Lubk, A.; Lichte, H.

    2014-01-15

    Tomographic techniques play a crucial role in imaging methods such as transmission electron microscopy (TEM) due to their unique capabilities to reconstruct three-dimensional object information. However, the accuracy of the two standard tomographic reconstruction techniques, the weighted back-projection (W-BP) and the simultaneous iterative reconstruction technique (SIRT) is reduced under common experimental restrictions, such as limited tilt range or noise. We demonstrate that the combination of W-BP and SIRT leads to an improved tomographic reconstruction technique: the weighted SIRT. Convergence, resolution and reconstruction error of the W-SIRT are analyzed by a detailed analytical, numerical, and experimental comparison with established methods. Our reconstruction technique is not restricted to TEM tomography but can be applied to all problems sharing single axis imaging geometry. - Highlights: • A new tomographic reconstruction technique W-SIRT was developed. • W-SIRT provides better convergence, higher resolution and smaller reconstruction error compared to established tomographic techniques. • This is demonstrated by a detailed analytical, numerical, and experimental comparison.

  3. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E; Haase, Robert; Laule, Michael

    2017-01-01

    OBJECTIVES: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninva...... angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low...

  4. Comparison of iterative reconstruction approaches for photoacoustic tomography

    Science.gov (United States)

    Zhang, Jin; Anastasio, Mark A.; La Rivière, Patrick J.

    2007-02-01

    In many iterative algorithms for photoacoustic tomography (PAT), images are reconstructed from an integrated data function g(r\\vec t) rather than from the measured acoustic pressure data function p(r\\vec; t). The integrated data function is related to the object by a spherical Radon transform, which can be inverted by use of standard reconstruction algorithms. In this work, we investigate a different reconstruction approach that utilizes the measured pressure data function p(r\\vec, t) to directly invert the PAT imaging model. We reveal that these two reconstruction approaches, which are preconditioned versions of each other, have distinct statistical and numerical properties. Each is demonstrated to have characteristics that are advantageous to certain types of data inconsistencies. Numerical results are presented to corroborate our analysis.

  5. Image Reconstruction Using a Genetic Algorithm for Electrical Capacitance Tomography

    Institute of Scientific and Technical Information of China (English)

    MOU Changhua; PENG Lihui; YAO Danya; XIAO Deyun

    2005-01-01

    Electrical capacitance tomography (ECT) has been used for more than a decade for imaging dielectric processes. However, because of its ill-posedness and non-linearity, ECT image reconstruction has always been a challenge. A new genetic algorithm (GA) developed for ECT image reconstruction uses initial results from a linear back-projection, which is widely used for ECT image reconstruction to optimize the threshold and the maximum and minimum gray values for the image. The procedure avoids optimizing the gray values pixel by pixel and significantly reduces the search space dimension. Both simulations and static experimental results show that the method is efficient and capable of reconstructing high quality images. Evaluation criteria show that the GA-based method has smaller image error and greater correlation coefficients. In addition, the GA-based method converges quickly with a small number of iterations.

  6. Electromagnetic tomography (EMT): image reconstruction based on the inverse problem

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Starting from Maxwell's equations for inhomogeneous media, nonlinear integral equations of the inverse problem of the electromagnetic tomography (EMT) are derived, whose kernel is the dyadic Green's function for the EMT sensor with a homogeneous medium in the object space. Then in terms of ill-posedness of the inverse problem, a Tikhonov-type regularization model is established based on a linearization-approximation of the nonlinear inverse problem. Finally, an iterative algorithm of image reconstruction based on the inverse problem and reconstruction images of some object flows for simplified sensor are given. Initial results of the image reconstruction show that the algorithm based on the inverse problem is superior to those based on the linear back-projection in the quality of image reconstruction.

  7. Full-Wave Iterative Image Reconstruction in Photoacoustic Tomography with Acoustically Inhomogeneous Media

    CERN Document Server

    Huang, Chao; Nie, Liming; Wang, Lihong V; Anastasio, Mark A

    2013-01-01

    Existing approaches to image reconstruction in photoacoustic computed tomography (PACT) with acoustically heterogeneous media are limited to weakly varying media, are computationally burdensome, and/or cannot effectively mitigate the effects of measurement data incompleteness and noise. In this work, we develop and investigate a discrete imaging model for PACT that is based on the exact photoacoustic (PA) wave equation and facilitates the circumvention of these limitations. A key contribution of the work is the establishment of a procedure to implement a matched forward and backprojection operator pair associated with the discrete imaging model, which permits application of a wide-range of modern image reconstruction algorithms that can mitigate the effects of data incompleteness and noise. The forward and backprojection operators are based on the k-space pseudospectral method for computing numerical solutions to the PA wave equation in the time domain. The developed reconstruction methodology is investigated...

  8. Reconstruction methods for phase-contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raven, C.

    1997-02-01

    Phase contrast imaging with coherent x-rays can be distinguished in outline imaging and holography, depending on the wavelength {lambda}, the object size d and the object-to-detector distance r. When r << d{sup 2}{lambda}, phase contrast occurs only in regions where the refractive index fastly changes, i.e. at interfaces and edges in the sample. With increasing object-to-detector distance we come in the area of holographic imaging. The image contrast outside the shadow region of the object is due to interference of the direct, undiffracted beam and a beam diffracted by the object, or, in terms of holography, the interference of a reference wave with the object wave. Both, outline imaging and holography, offer the possibility to obtain three dimensional information of the sample in conjunction with a tomographic technique. But the data treatment and the kind of information one can obtain from the reconstruction is different.

  9. Image-reconstruction methods in positron tomography

    CERN Document Server

    Townsend, David W; CERN. Geneva

    1993-01-01

    Physics and mathematics for medical imaging In the two decades since the introduction of the X-ray scanner into radiology, medical imaging techniques have become widely established as essential tools in the diagnosis of disease. As a consequence of recent technological and mathematical advances, the non-invasive, three-dimensional imaging of internal organs such as the brain and the heart is now possible, not only for anatomical investigations using X-rays but also for studies which explore the functional status of the body using positron-emitting radioisotopes and nuclear magnetic resonance. Mathematical methods which enable three-dimentional distributions to be reconstructed from projection data acquired by radiation detectors suitably positioned around the patient will be described in detail. The lectures will trace the development of medical imaging from simpleradiographs to the present-day non-invasive measurement of in vivo boichemistry. Powerful techniques to correlate anatomy and function that are cur...

  10. Computed tomography of the patellofemoral alignment after arthroscopic reconstruction following patella dislocation; Postoperative Bestimmung des patellofemoralen Alignements nach Patellaluxation - eine computertomographische Analyse

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, R.J.; Hidajat, N.; Maeurer, J.; Felix, R. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-Univ. Berlin (Germany); Weiler, A.; Hoeher, J. [Sektion Sporttraumatologie und Arthroskopie, Klinik fuer Unfall- und Wiederherstellungschirurgie, Charite, Campus Virchow-Klinikum, Humboldt-Univ. Berlin (Germany)

    2003-04-01

    Purpose: To evaluate the diagnostic impact of different CT-based measurements to analyze the patellofemoral alignment after arthroscopic reconstruction in patients with patella dislocation. Materials and Methods: In 18 patients with dislocation of the patella, CT of the patellofemoral joint was performed after arthroscopic reconstruction. Various methods recommended in the literature were used to analyze the structure and the alignment of the patellofemoral joint with a relaxed quadriceps muscle. Axial CT scans were taken in four different knee flexion angles (15 , 30 , 45 , 60 ). Results: After arthroscopic stabilization in patients with patella dislocation, only the lateral patellofemoral angle (15 and 30 knee flexion) and the congruence angle (15 knee flexion) showed significant differences between the CT-measurements in the normal and the operated group. The differences of the remaining mean values were not significant due to a high standard deviation. With increasing flexion of the knee, the differences between the normal and the dislocation group almost disappeared. Only the lateral patellofemoral angle, the patella tilt and the lateral patella shift revealed differences between the normal and the group with recurrent dislocation in every degree of knee flexion. With increasing knee flexion above 30 and especially at 60 , the majority of the measured values returned to the normal range. Conclusions: For CT-measurements of the patellofemoral joint after arthroscopic stabilization, the patellofemoral angle and the congruence angle seemed to be most useful. The measurements of the patellofemoral joint should be taken in various degrees of knee flexion. (orig.) [German] Ziel: Evaluation der Aussagekraft verschiedener CT-Vermessungsmethoden des Patellofemoralgelenkes nach arthroskopischer Stabilisierung bei Patellaluxation. Material und Methode: Axiale CT-Vermessung des Patellofemoralgelenkes bei 18 Patienten nach arthroskopischer medialer patellofemoraler Naht

  11. X-ray computed tomography of PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Pfrang, Andreas; Veyret, Damien; Tsotridis, Georgios [Commission of the European Communities, Petten (Netherlands). Joint Reseach Centre, Inst. for Energy; Janssen, Gaby [Energy Research Centre of the Netherlands ECN, Petten (Netherlands). Dept. of Hydrogen and Clean Fossil Fuels

    2010-07-01

    Proton exchange membrane (PEM) fuel cells were investigated by 3D x-ray computed tomography at a voxel size of 0.7 {mu}m. It is shown that this lab-based technique is not only suitable for the investigation of gas diffusion layers (GDL) as well as the investigation of membrane electrode assemblies (MEA), but also allows the calculation of macroscopic physical properties. The resolution of computed tomography is clearly sufficient to image the carbon fiber structure of gas diffusion layers in the as received GDLs as well as GDLs integrated into membrane electrode assemblies. It is also possible to visualize the catalyst layer within the MEA, which allows the investigation of layer thickness and structural defects on a larger scale than with conventional techniques. The macroscopic effective thermal conductivities of the gas diffusion layers were computed based on the 3D GDL structure reconstructed from tomography data to produce more reliable input data for fuel cell modeling. The computation was carried out by solving the energy equation considering a pure thermal conduction problem. The computations show - in agreement with the expectation and experimental data - that the through-plane thermal conductivities are lower than the in-plane thermal conductivities. (orig.)

  12. FIRST: Fast Iterative Reconstruction Software for (PET) tomography

    CERN Document Server

    Herraiz, J L; Vaquero, J J; Desco, M; Udias, J M

    2006-01-01

    Small animal PET scanners require high spatial resolution and good sensitivity. To reconstruct high-resolution images in 3D-PET, iterative methods, such as OSEM, are superior to analytical reconstruction algorithms, although their high computational cost is still a serious drawback. The higher performance of modern computers could make iterative image reconstruction fast enough to be viable, provided we are able to deal with the large number of probability coefficients for the system response matrix in high-resolution PET scanners, which is a difficult task that prevents the algorithms from reaching peak computing performance. Considering all possible axial and in-plane symmetries, as well as certain quasi-symmetries, we have been able to reduce the memory requirements to store the system response matrix (SRM) well below 1 GB, which allows us to keep the whole response matrix of the system inside RAM of ordinary industry-standard computers, so that the reconstruction algorithm can achieve near peak performanc...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... of the machine, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  17. Ultrasound Tomography in Circular Measurement Configuration using Nonlinear Reconstruction Method

    Directory of Open Access Journals (Sweden)

    Tran Quang-Huy

    2015-12-01

    Full Text Available Ultrasound tomography offers the potential for detecting of very small tumors whose sizes are smaller than the wavelength of the incident pressure wave without ionizing radiation. Based on inverse scattering technique, this imaging modality uses some material properties such as sound contrast and attenuation in order to detect small objects. One of the most commonly used methods in ultrasound tomography is the Distorted Born Iterative Method (DBIM. The compressed sensing technique was applied in the DBIM as a promising approach for the image reconstruction quality improvement. Nevertheless, the random measurement configuration of transducers in this method is very difficult to set up in practice. Therefore, in this paper, we take advantages of simpler sparse uniform measurement configuration set-up of transducers and high-quality image reconstruction of 1 non-linear regularization in sparse scattering domain. The simulation results demonstrate the high performance of the proposed approach in terms of tremendously reduced total runtime and normalized error.

  18. Analysis of lumbar pedicle morphology in degenerative spines using multiplanar reconstruction computed tomography: what can be the reliable index for optimal pedicle screw diameter?

    Science.gov (United States)

    Makino, Takahiro; Kaito, Takashi; Fujiwara, Hiroyasu; Yonenobu, Kazuo

    2012-08-01

    The measurement of transverse pedicle width is still recommended for selecting a screw diameter despite being weakly correlated with the minimum pedicle diameter, except in the upper lumbar spine. The purpose of this study was to reveal the difference between the minimum pedicle diameter and conventional transverse or sagittal pedicle width in degenerative lumbar spines. A total of 50 patients with degenerative lumbar disorders without spondylolysis or lumbar scoliosis of >10° who preoperatively underwent helical CT scans were included. The DICOM data of the scans were reconstructed by imaging software, and the transverse pedicle width (TPW), sagittal pedicle width (SPW), minimum pedicle diameter (MPD), and the cephalocaudal inclination of the pedicles were measured. The mean TPW/SPW/MPD values were 5.46/11.89/5.09 mm at L1, 5.76/10.44/5.39 mm at L2, 7.25/10.23/6.52 mm at L3, 9.01/9.36/6.83 mm at L4, and 12.86/8.95/7.36 mm at L5. There were significant differences between the TPW and MPD at L3, L4, and L5 (p < 0.01) and between the SPW and MPD at all levels (p < 0.01). The MPD was significantly smaller than the TPW and SPW at L3, L4, and L5. The actual measurements of the TPW were not appropriate for use as a direct index for the optimal pedicle screw diameter at these levels. Surgeons should be careful in determining pedicle screw diameter based on plain CT scans especially in the lower lumbar spine.

  19. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, CHU Grenoble (France)

    2000-02-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  20. Physical-space refraction-corrected transmission ultrasound computed tomography made computationally practical.

    Science.gov (United States)

    Li, Shengying; Mueller, Klaus; Jackowski, Marcel; Dione, Donald; Staib, Lawrence

    2008-01-01

    Transmission Ultrasound Computed Tomography (CT) is strongly affected by the acoustic refraction properties of the imaged tissue, and proper modeling and correction of these effects is crucial to achieving high-quality image reconstructions. A method that can account for these refractive effects solves the governing Eikonal equation within an iterative reconstruction framework, using a wave-front tracking approach. Excellent results can be obtained, but at considerable computational expense. Here, we report on the acceleration of three Eikonal solvers (Fast Marching Method (FMM), Fast Sweeping Method (FSM), Fast Iterative Method (FIM)) on three computational platforms (commodity graphics hardware (GPUs), multi-core and cluster CPUs), within this refractive Transmission Ultrasound CT framework. Our efforts provide insight into the capabilities of the various architectures for acoustic wave-front tracking, and they also yield a framework that meets the interactive demands of clinical practice, without a loss in reconstruction quality.

  1. Cervical diplomyelia revealed by computed tomography (CT)

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, G.B.; Davidovits, P.; Cerisoli, M.; Giulioni, M.

    1982-05-01

    An unusual case of cervical diplomyelia diagnosed by Computed Tomography (CT) is reported. The usefulness of CT examination in the evaluation of spinal dysraphic defects is emphasized, though performed without CSF enhancement. Visualisation of spinal cord splitting in the absence of bony spicula allows the authors to differentiate between diplomyelia and diastematomyelia which have been often described by using both terms interchangeably.

  2. Computed tomography demonstration of cholecystogastric fistula

    Directory of Open Access Journals (Sweden)

    Chung Kuao Chou, MD, MPH

    2016-06-01

    Full Text Available Cholecystogastric fistula is a rare complication of chronic cholecystitis or long-standing cholelithiasis. It results from the gradual erosion of the approximated, chronically inflamed wall of the gall bladder and stomach with fistulous tract formation. The present case describes the direct visualization of a cholecystogastric fistula by computed tomography in a patient without prior biliary system complaints.

  3. Computed tomography in untreated congenital adrenal hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Harinarayana, C.V.; Renu, G.; Ammini, A.C.; Khurana, M.L.; Ved, P.; Karmarkar, M.G.; Ahuja, M.M.S.; Berry, M. (AIIMS, New Delhi (India))

    1991-02-01

    Six children with untreated congenital adrenal hyperplasia (CAH) were examined by computed tomography (CT). Three cases demonstrated diffuse enlargement of both adrenal glands with preservation of normal configuration and two showed tumorous transformation in one of the enlarged glands. One had equivocal in this group (age 2 years) also showed bilateral hyperplasia. (orig.).

  4. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  5. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  6. Neutron computed tomography of rat lungs

    Energy Technology Data Exchange (ETDEWEB)

    Metzke, R W; Wall, W A [Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany); Runck, H; Stahl, C A; Schneider, M; Guttmann, J [Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany); Schillinger, B; Calzada, E; Muehlbauer, M; Schulz, M [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany); Priebe, H-J, E-mail: metzke@lnm.mw.tum.d [Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

    2011-01-07

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 {mu}m, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  7. Simultaneous reconstruction of outer boundary shape and conductivity distribution in electrical impedance tomography

    KAUST Repository

    Hyvönen, Nuutti

    2016-01-05

    The simultaneous retrieval of the exterior boundary shape and the interior admittivity distribution of an examined body in electrical impedance tomography is considered. The reconstruction method is built for the complete electrode model and it is based on the Frechet derivative of the corresponding current-to-voltage map with respect to the body shape. The reconstruction problem is cast into the Bayesian framework, and maximum a posteriori estimates for the admittivity and the boundary geometry are computed. The feasibility of the approach is evaluated by experimental data from water tank measurements.

  8. Breast ultrasound computed tomography using waveform inversion with source encoding

    Science.gov (United States)

    Wang, Kun; Matthews, Thomas; Anis, Fatima; Li, Cuiping; Duric, Neb; Anastasio, Mark A.

    2015-03-01

    Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the speed-of-sound distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Computer-simulation studies are conducted to demonstrate the use of the WISE method. Using a single graphics processing unit card, each iteration can be completed within 25 seconds for a 128 × 128 mm2 reconstruction region. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden.

  9. Visibility of Sutures of the Orbit and Periorbital Region Using Multidetector Computed Tomography

    OpenAIRE

    2014-01-01

    Objective Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Materials and Methods Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube...

  10. Computed tomography of tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto (Kobe Univ. (Japan). School of Medicine)

    1982-12-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis.

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, so that the x-ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the body, to ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  13. Single photon emission computed tomography/computed tomography for malignant otitis externa: lesion not shown on planar image.

    Science.gov (United States)

    Chen, Yu-Hung; Hsieh, Hung-Jen

    2013-01-01

    Malignant otitis externa is a severe and rare infection of the external acoustic meatus. Triphasic bone and (67)Ga scintigraphies are used to initial detect and follow-up the response of therapy. With single photon emission computed tomography/computed tomography images, the diagnostic sensitivity is higher. We presented a case with malignant otitis externa with initial negative planar scintigraphic finding. The lesion was detected by photon emission computed tomography/computed tomography images. We concluded that the photon emission computed tomography/computed tomography should be performed routinely for patients with suspected malignant otitis externa, even without evidence of lesion on planar images.

  14. Image reconstruction technique using projection data from neutron tomography system

    Directory of Open Access Journals (Sweden)

    Waleed Abd el Bar

    2015-12-01

    Full Text Available Neutron tomography is a very powerful technique for nondestructive evaluation of heavy industrial components as well as for soft hydrogenous materials enclosed in heavy metals which are usually difficult to image using X-rays. Due to the properties of the image acquisition system, the projection images are distorted by several artifacts, and these reduce the quality of the reconstruction. In order to eliminate these harmful effects the projection images should be corrected before reconstruction. This paper gives a description of a filter back projection (FBP technique, which is used for reconstruction of projected data obtained from transmission measurements by neutron tomography system We demonstrated the use of spatial Discrete Fourier Transform (DFT and the 2D Inverse DFT in the formulation of the method, and outlined the theory of reconstruction of a 2D neutron image from a sequence of 1D projections taken at different angles between 0 and π in MATLAB environment. Projections are generated by applying the Radon transform to the original image at different angles.

  15. Positron Emission Tomography with Three-Dimensional Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of `mobile pixels`, which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs.

  16. Urologic applications of multiplanar and three-dimensional computed tomography.

    Science.gov (United States)

    Olson, M C; Posniak, H V

    1995-01-01

    The introduction of helical computed tomography (CT) has resulted in improved quality of multiplanar reformations and three-dimensional reconstructions in the chest and abdomen and has made CT angiography a clinical reality. These imaging techniques are useful for evaluating the urinary tract, adding a new dimension to its display, resulting in improved diagnosis of renal and perirenal disease. This article reviews the indications and techniques utilized for multiplanar and three-dimensional CT for urology. The advantages and limitations are discussed, and normal and pathologic findings in the urinary tract illustrated.

  17. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  18. Computed tomography in mitochondrial cytopathy

    Energy Technology Data Exchange (ETDEWEB)

    Egger, J.; Kendall, B.E.

    1981-10-01

    The clinical and computed tomographic (CT) findings in 11 proven cases of mitochondrial cytopathy (mitochondrial myopathy, Kearns Sayre syndrome, ophthalmoplegia plus) were studied. The CT changes included focal low density lesions in the basal ganglia and white matter and atrophy which could be slight or diffuse and severe. Calcification has been described in the basal ganglia, but did not occur in our series. Serial CT showed progression of the abnormalities. The differential diagnosis is discussed.

  19. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  20. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  1. Trip report: Marshall Space Center computed tomography

    Science.gov (United States)

    Harbour, J. R.; Andrews, M. K.

    BIR Inc. is a small company out of the Chicago area which sells equipment for producing images by tomography. They have built a relatively large instrument, called ACTIS, for NASA at the Marshall Space Center in Huntsville, Alabama and still gave access to this instrument. BIR has a grant from the Department of Energy (DOE) to determine the utility of computed tomography (CT) for characterization of nuclear and hazardous waste within the DOE complex. As part of this effort, the potential of this technique for obtaining images of canistered waste forms has been investigated. Funding for data acquisition was provided through this grant.

  2. Parallel programming of gradient-based iterative image reconstruction schemes for optical tomography.

    Science.gov (United States)

    Hielscher, Andreas H; Bartel, Sebastian

    2004-02-01

    Optical tomography (OT) is a fast developing novel imaging modality that uses near-infrared (NIR) light to obtain cross-sectional views of optical properties inside the human body. A major challenge remains the time-consuming, computational-intensive image reconstruction problem that converts NIR transmission measurements into cross-sectional images. To increase the speed of iterative image reconstruction schemes that are commonly applied for OT, we have developed and implemented several parallel algorithms on a cluster of workstations. Static process distribution as well as dynamic load balancing schemes suitable for heterogeneous clusters and varying machine performances are introduced and tested. The resulting algorithms are shown to accelerate the reconstruction process to various degrees, substantially reducing the computation times for clinically relevant problems.

  3. Accelerated reconstruction of electrical impedance tomography images via patch based sparse representation

    Science.gov (United States)

    Wang, Qi; Lian, Zhijie; Wang, Jianming; Chen, Qingliang; Sun, Yukuan; Li, Xiuyan; Duan, Xiaojie; Cui, Ziqiang; Wang, Huaxiang

    2016-11-01

    Electrical impedance tomography (EIT) reconstruction is a nonlinear and ill-posed problem. Exact reconstruction of an EIT image inverts a high dimensional mathematical model to calculate the conductivity field, which causes significant problems regarding that the computational complexity will reduce the achievable frame rate, which is considered as a major advantage of EIT imaging. The single-step method, state estimation method, and projection method were always used to accelerate reconstruction process. The basic principle of these methods is to reduce computational complexity. However, maintaining high resolution in space together with not much cost is still challenging, especially for complex conductivity distribution. This study proposes an idea to accelerate image reconstruction of EIT based on compressive sensing (CS) theory, namely, CSEIT method. The novel CSEIT method reduces the sampling rate through minimizing redundancy in measurements, so that detailed information of reconstruction is not lost. In order to obtain sparse solution, which is the prior condition of signal recovery required by CS theory, a novel image reconstruction algorithm based on patch-based sparse representation is proposed. By applying the new framework of CSEIT, the data acquisition time, or the sampling rate, is reduced by more than two times, while the accuracy of reconstruction is significantly improved.

  4. Monte Carlo simulation of gamma ray tomography for image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, Karlos A.N.; Moura, Alex; Dantas, Carlos; Melo, Silvio; Lima, Emerson, E-mail: karlosguedes@hotmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Meric, Ilker [University of Bergen (Norway)

    2015-07-01

    The Monte Carlo simulations of known density and shape object was validate with Gamma Ray Tomography in static experiments. An aluminum half-moon piece placed inside a steel pipe was the MC simulation test object that was also measured by means of gamma ray transmission. Wall effect of the steel pipe due to irradiation geometry in a single pair source-detector tomography was evaluated by comparison with theoretical data. MCNPX code requires a defined geometry to each photon trajectory which practically prevents this usage for tomography reconstruction simulation. The solution was found by writing a program in Delphi language to create input files automation code. Simulations of tomography data by automated MNCPX code were carried out and validated by experimental data. Working in this sequence the produced data needed a databank to be stored. Experimental setup used a Cesium-137 isotopic radioactive source (7.4 × 109 Bq), and NaI(Tl) scintillation detector of (51 × 51) × 10−3 m crystal size coupled to a multichannel analyzer. A stainless steel tubes of 0,154 m internal diameter, 0.014 m thickness wall. The results show that the MCNPX simulation code adapted to automated input file is useful for generating a matrix data M(θ,t), of a computerized gamma ray tomography for any known density and regular shape object. Experimental validation used RMSE from gamma ray paths and from attenuation coefficient data. (author)

  5. Feasible Dose Reduction in Routine Chest Computed Tomography Maintaining Constant Image Quality Using the Last Three Scanner Generations: From Filtered Back Projection to Sinogram-affirmed Iterative Reconstruction and Impact of the Novel Fully Integrated Detector Design Minimizing Electronic Noise

    Directory of Open Access Journals (Sweden)

    Lukas Ebner

    2014-01-01

    Full Text Available Objective:The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP and an iterative reconstruction (IR algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany was investigated. Materials and Methods: 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP, SOMATOM Definition Flash (IR, and SOMATOM Definition Edge (ICD and IR. Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. Results: Dose-length product (DLP with FBP for the average chest CT was 308 mGycm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGycm ± 68.8 (P = 0.0001. Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGycm ± 54.5 (P = 0.033. The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048. Overall contrast-to-noise ratio (CNR improved with declining DLP. Conclusion: The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

  6. Image reconstruction based on L1 regularization and projection methods for electrical impedance tomography.

    Science.gov (United States)

    Wang, Qi; Wang, Huaxiang; Zhang, Ronghua; Wang, Jinhai; Zheng, Yu; Cui, Ziqiang; Yang, Chengyi

    2012-10-01

    Electrical impedance tomography (EIT) is a technique for reconstructing the conductivity distribution by injecting currents at the boundary of a subject and measuring the resulting changes in voltage. Image reconstruction in EIT is a nonlinear and ill-posed inverse problem. The Tikhonov method with L(2) regularization is always used to solve the EIT problem. However, the L(2) method always smoothes the sharp changes or discontinue areas of the reconstruction. Image reconstruction using the L(1) regularization allows addressing this difficulty. In this paper, a sum of absolute values is substituted for the sum of squares used in the L(2) regularization to form the L(1) regularization, the solution is obtained by the barrier method. However, the L(1) method often involves repeatedly solving large-dimensional matrix equations, which are computationally expensive. In this paper, the projection method is combined with the L(1) regularization method to reduce the computational cost. The L(1) problem is mainly solved in the coarse subspace. This paper also discusses the strategies of choosing parameters. Both simulation and experimental results of the L(1) regularization method were compared with the L(2) regularization method, indicating that the L(1) regularization method can improve the quality of image reconstruction and tolerate a relatively high level of noise in the measured voltages. Furthermore, the projected L(1) method can also effectively reduce the computational time without affecting the quality of reconstructed images.

  7. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  8. Comparison with reconstruction algorithms in magnetic induction tomography.

    Science.gov (United States)

    Han, Min; Cheng, Xiaolin; Xue, Yuyan

    2016-05-01

    Magnetic induction tomography (MIT) is a kind of imaging technology, which uses the principle of electromagnetic detection to measure the conductivity distribution. In this research, we make an effort to improve the quality of image reconstruction mainly via the image reconstruction of MIT analysis, including solving the forward problem and image reconstruction. With respect to the forward problem, the variational finite element method is adopted. We transform the solution of a nonlinear partial differential equation into linear equations by using field subdividing and the appropriate interpolation function so that the voltage data of the sensing coils can be calculated. With respect to the image reconstruction, a method of modifying the iterative Newton-Raphson (NR) algorithm is presented in order to improve the quality of the image. In the iterative NR, weighting matrix and L1-norm regularization are introduced to overcome the drawbacks of large estimation errors and poor stability of the reconstruction image. On the other hand, within the incomplete-data framework of the expectation maximization (EM) algorithm, the image reconstruction can be converted to the problem of EM through the likelihood function for improving the under-determined problem. In the EM, the missing-data is introduced and the measurement data and the sensitivity matrix are compensated to overcome the drawback that the number of the measurement voltage is far less than the number of the unknown. In addition to the two aspects above, image segmentation is also used to make the lesion more flexible and adaptive to the patients' real conditions, which provides a theoretical reference for the development of the application of the MIT technique in clinical applications. The results show that solving the forward problem with the variational finite element method can provide the measurement voltage data for image reconstruction, the improved iterative NR method and EM algorithm can enhance the image

  9. Computed tomography of bones and joints.

    Science.gov (United States)

    Bruna, J; Sehr, A

    1989-01-01

    The monograph sums up the problem of CT diagnosis of bones and joints making use of predominantly the authors' own experience based on CT tests of more than 45,000 patients examined at the Department of Radiology, Charles University Medical Faculty of Hygiene teaching hospital in Prague in the years 1980-1988. Specific scans of the skeleton were made in 4,500 patients, mostly for suspicion or closer assessment of neoplasms (43.5%), the radicular lumbosacral syndrome (34.5%), and injuries (12%). The opening chapters sum up basic facts about the principle of computed tomography, the apparatus in use, the evaluation of CT images, CT radiation doses, and the patients' preparation for CT scanning. The use of contrast media is discussed with regard to the possible hazards involved and to the need to hear allergological opinion first. For spinal canal visualization non-ionogenic contrast media are used exclusively. The management of side reactions to contrast medium application is also reviewed. Indications for bone and joint computed tomography now comprise a whole series of traumatological, orthopaedic, oncological, rheumatological, neurological and rehabilitation conditions, each of which is discussed in detail in a separate chapter. CT anatomical studies offer the advantage of being applicable even in patients examined for other than bone or articular diseases. The option of simultaneous soft tissue assessment represents another advantage. The authors describe different anatomical structures in terms of CT images, some of them complete with dimensional and density values. The chapter on anomalies and developmental variants stresses the relevance of computed tomography for precise characteristics of clefts of the spinal column and facial bones and for the diagnosis of anomalies and dysplasias of the spinal column and the chest. A rare case of cephalothoracopagus is demonstrated. As for traumatology, computed tomography is found useful in diagnosing fractures of the

  10. Image quality of mixed convolution kernel in thoracic computed tomography.

    Science.gov (United States)

    Neubauer, Jakob; Spira, Eva Maria; Strube, Juliane; Langer, Mathias; Voss, Christian; Kotter, Elmar

    2016-11-01

    The mixed convolution kernel alters his properties geographically according to the depicted organ structure, especially for the lung. Therefore, we compared the image quality of the mixed convolution kernel to standard soft and hard kernel reconstructions for different organ structures in thoracic computed tomography (CT) images.Our Ethics Committee approved this prospective study. In total, 31 patients who underwent contrast-enhanced thoracic CT studies were included after informed consent. Axial reconstructions were performed with hard, soft, and mixed convolution kernel. Three independent and blinded observers rated the image quality according to the European Guidelines for Quality Criteria of Thoracic CT for 13 organ structures. The observers rated the depiction of the structures in all reconstructions on a 5-point Likert scale. Statistical analysis was performed with the Friedman Test and post hoc analysis with the Wilcoxon rank-sum test.Compared to the soft convolution kernel, the mixed convolution kernel was rated with a higher image quality for lung parenchyma, segmental bronchi, and the border between the pleura and the thoracic wall (P kernel, the mixed convolution kernel was rated with a higher image quality for aorta, anterior mediastinal structures, paratracheal soft tissue, hilar lymph nodes, esophagus, pleuromediastinal border, large and medium sized pulmonary vessels and abdomen (P kernel cannot fully substitute the standard CT reconstructions. Hard and soft convolution kernel reconstructions still seem to be mandatory for thoracic CT.

  11. Concluding Report: Quantitative Tomography Simulations and Reconstruction Algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Aufderheide, M B; Martz, H E; Slone, D M; Jackson, J A; Schach von Wittenau, A E; Goodman, D M; Logan, C M; Hall, J M

    2002-02-01

    In this report we describe the original goals and final achievements of this Laboratory Directed Research and Development project. The Quantitative was Tomography Simulations and Reconstruction Algorithms project (99-ERD-015) funded as a multi-directorate, three-year effort to advance the state of the art in radiographic simulation and tomographic reconstruction by improving simulation and including this simulation in the tomographic reconstruction process. Goals were to improve the accuracy of radiographic simulation, and to couple advanced radiographic simulation tools with a robust, many-variable optimization algorithm. In this project, we were able to demonstrate accuracy in X-Ray simulation at the 2% level, which is an improvement of roughly a factor of 5 in accuracy, and we have successfully coupled our simulation tools with the CCG (Constrained Conjugate Gradient) optimization algorithm, allowing reconstructions that include spectral effects and blurring in the reconstructions. Another result of the project was the assembly of a low-scatter X-Ray imaging facility for use in nondestructive evaluation applications. We conclude with a discussion of future work.

  12. Cone Beam Computed Tomography Evaluation of Inverted Mesiodentes.

    Science.gov (United States)

    Al-Sehaibany, Fares S; Marzouk, Hazem M; Salama, Fouad S

    2016-01-01

    A mesiodens is the most common type of supernumerary teeth. The purpose of this report is to present a rare occurrence of non-syndromic impacted inverted mesiodentes in an 8.5-year-old boy who presented with a chief complaint of delayed eruption of his permanent maxillary left central incisor. Occlusal and panoramic radiographs, as well as cone beam computed tomography (CBCT) with a three-dimensional (3-D) reconstruction image, confirmed that one supernumerary tooth had perforated the nasal fossa floor and the other was in close approximation to the to the same site. Surgical removal of both mesiodentes was indicated. Radiographic evidence of complete healing was observed 12 months following surgical removal. The use of CBCT with a 3-D reconstruction image as a tool in diagnosis and evaluation of healing after surgical removal is recommended.

  13. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  14. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    -CCTR, showed that coronary CT angiographies accounted for only 23% of all nonregistered cardiac CTs, indicating >90% completeness of coronary CT angiographies in the WDHR-CCTR. The completeness of individual variables varied substantially (range: 0%-100%), but was >85% for more than 70% of all variables. Using......BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... expected numbers; and 4) positive predictive values as well as negative predictive values of 19 main patient and procedure variables. RESULTS: By December 31, 2012, almost 22,000 cardiac CTs with up to 40 variables for each procedure have been registered. Of these, 87% were coronary CT angiography...

  15. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  16. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon, E-mail: conordurack1@hotmail.com [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  17. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  18. Cone beam computed tomography in endodontics.

    Science.gov (United States)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillo-facial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontics. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice.

  19. Computed tomography of ancient Egyptian mummies.

    Science.gov (United States)

    Harwood-Nash, D C

    1979-12-01

    This first report of the application of computed tomography (CT) to the study of ancient mummies, the desiccated brain of a boy and the body of a young woman within her cartonnage, shows that CT is uniquely suitable for the study of such antiquities, a study that does not necessitate destruction of the mummy or its cartonnage. Exquisite images result that are of great paleoanatomical, paleopathological, and archeological significance.

  20. Computed tomography and obstructive biliary disease.

    Science.gov (United States)

    Havrilla, T R; Haaga, J R; Alfidi, R J; Reich, N E

    1977-05-01

    Forty-four patients with confirmed biliary diseases were studied to determine the value of computed tomography (CT) in the diagnosis of biliary pathology. The results indicate that CT is useful and highly accurate in differentiating between obstructive (surgical) and nonobstructive (medical) disease entities. Of the cases with proved obstruction, 88% were correctly identified. All of the nonobstructive cases had positive CT correlation. In addition, the underlying cause of the occlusion was determined in the majority of cases.

  1. Cone Beam Computed Tomography - Know its Secrets

    OpenAIRE

    Kumar, Mohan; Shanavas, Muhammad; Sidappa, Ashwin; Kiran, Madhu

    2015-01-01

    Cone-beam computed tomography (CBCT) is an advanced imaging modality that has high clinical applications in the field of dentistry. CBCT proved to be a successful investigative modality that has been used for dental and maxillofacial imaging. Radiation exposure dose from CBCT is 10 times less than from conventional CT scans during maxillofacial exposure. Furthermore, CBCT is highly accurate and can provide a three-dimensional volumetric data in axial, sagittal and coronal planes. This article...

  2. Cone beam computed tomography use in orthodontics.

    Science.gov (United States)

    Nervina, J M

    2012-03-01

    Cone beam computed tomography (CBCT) is widely used by orthodontists to obtain three-dimensional (3-D) images of their patients. This is of value as malocclusion results from discrepancies in three planes of space. This review tracks the use of CBCT in orthodontics, from its validation as an accurate and reliable tool, to its use in diagnosing and treatment planning, and in assessing treatment outcomes in orthodontics.

  3. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  4. In vivo bioluminescence tomography based on multi-view projection and 3D surface reconstruction

    Science.gov (United States)

    Zhang, Shuang; Wang, Kun; Leng, Chengcai; Deng, Kexin; Hu, Yifang; Tian, Jie

    2015-03-01

    Bioluminescence tomography (BLT) is a powerful optical molecular imaging modality, which enables non-invasive realtime in vivo imaging as well as 3D quantitative analysis in preclinical studies. In order to solve the inverse problem and reconstruct inner light sources accurately, the prior structural information is commonly necessary and obtained from computed tomography or magnetic resonance imaging. This strategy requires expensive hybrid imaging system, complicated operation protocol and possible involvement of ionizing radiation. The overall robustness highly depends on the fusion accuracy between the optical and structural information. In this study we present a pure optical bioluminescence tomographic system (POBTS) and a novel BLT method based on multi-view projection acquisition and 3D surface reconstruction. The POBTS acquired a sparse set of white light surface images and bioluminescent images of a mouse. Then the white light images were applied to an approximate surface model to generate a high quality textured 3D surface reconstruction of the mouse. After that we integrated multi-view luminescent images based on the previous reconstruction, and applied an algorithm to calibrate and quantify the surface luminescent flux in 3D.Finally, the internal bioluminescence source reconstruction was achieved with this prior information. A BALB/C mouse with breast tumor of 4T1-fLuc cells mouse model were used to evaluate the performance of the new system and technique. Compared with the conventional hybrid optical-CT approach using the same inverse reconstruction method, the reconstruction accuracy of this technique was improved. The distance error between the actual and reconstructed internal source was decreased by 0.184 mm.

  5. Pneumatization of the temporal portion of the zygomatic arch: The contribution of computed tomography to the reconstruction in volumetric two-dimensional and three-dimensional, with the aid of image rendering protocols

    Directory of Open Access Journals (Sweden)

    C M Romano-Sousa

    2015-01-01

    Full Text Available Pneumatization refers to the asymptomatic development of cavities containing air within them. There is great variability in the extent of temporal bone pneumatization. Nevertheless, in a few cases it extends to the zygomatic process. Images are presented in which the panoramic radiograph and hypocycloidal tomography reveal this variation from the norm, to which professionals must be alert, since the images may simulate the presence of pathology. In this case report we describe the presence of pneumatization of the petrous and zygomatic portions of the temporal bone, demonstrating the contribution of CT to reconstruction in volumetric 2D and 3D, with the aid of image rendering protocols.

  6. CT三维重建技术对骶髂关节理想螺钉选择的意义%Significance of Three-dimensional Computed Tomography Reconstruction on Choice of Ideal Screw of the Sacroiliac Joint

    Institute of Scientific and Technical Information of China (English)

    刘新园; 黄继锋; 付强; 刘忠; 赵卫东

    2012-01-01

    目的 应用CT三维重建技术测量骶髂关节理想螺钉的形态,并验证其准确性与探讨其临床意义.方法 应用CT三维重建技术,对11例冰冻正常成人骨盆标本左右侧骶髂关节进行模拟骶髂螺钉内固定术,并测量骶髂关节理想螺钉的形态;根据CT测量结果,在11例骨盆标本(22个骶髂关节)上进行个体化置钉验证.结果 理想螺钉的长度与最大直径分别为(87.62±1.68) mm与(20.26±1.20) mm,理想螺钉与冠状面、水平面的夹角分别是(25.85±1.06)°与(19.79±1.60)°,进针点与髂后上、下棘的距离分别为(37.02±1.67) mm与(38.30±1.14) mm;左右侧骶髂关节所置螺钉均安全、准确到达预定位置.结论 应用CT三维重建技术模拟骶髂螺钉内固定术,可准确测量骶髂关节理想螺钉的形态并进行评估,对术中置入螺钉的进针点、角度和形态的选择有指导意义;同一个体左右侧骶髂关节理想螺钉的形态无明显差别.%Objective To study the application of three-dimensional computed tomography (CT) reconstruction in measuring the morphometry of ideal screw of the sacroiliac joint, validate the accuracy and explore the clinical significance. Methods The left and right sacroiliac joints of 11 frozen pelvic specimens of normal adults underwent internal fixation using sacroiliac screw by three-dimensional CT reconstruction, and the ideal shapes of the sacroiliac screw were measured. According to the measurement results, 11 pelvic specimens (22 sacroiliac joints) were individually validated by the iliosacral screws. Results The diameter of the deal screw was (20. 26 ± 1. 20) mm, and the length was (87.62 ± 1. 68) mm. The direction of the ideal screw was (25. 85 ± 1. 06)° to the coronal plane, and (19. 79 ± 1. 60)° to the horizontal plane. The distance from the entry point to the posterior superior iliac spine was (37. 02 ± 1. 67) mm, and to the posterior inferior iliac spine (38.30 ± 1. 14) mm. All the

  7. FIRST: Fast Iterative Reconstruction Software for (PET) tomography

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J L [Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S [Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Vaquero, J J [Unidad de Medicina y CirugIa Experimental, Hospital GU Gregorio Maranon, Madrid (Spain); Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital GU Gregorio Maranon, Madrid (Spain); UdIas, J M [Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2006-09-21

    Small animal PET scanners require high spatial resolution and good sensitivity. To reconstruct high-resolution images in 3D-PET, iterative methods, such as OSEM, are superior to analytical reconstruction algorithms, although their high computational cost is still a serious drawback. The higher performance of modern computers could make iterative image reconstruction fast enough to be viable, provided we are able to deal with the large number of probability coefficients for the system response matrix in high-resolution PET scanners, which is a difficult task that prevents the algorithms from reaching peak computing performance. Considering all possible axial and in-plane symmetries, as well as certain quasi-symmetries, we have been able to reduce the memory requirements to store the system response matrix (SRM) well below 1 GB, which allows us to keep the whole response matrix of the system inside RAM of ordinary industry-standard computers, so that the reconstruction algorithm can achieve near peak performance. The elements of the SRM are stored as cubic spline profiles and matched to voxel size during reconstruction. In this way, the advantages of 'on-the-fly' calculation and of fully stored SRM are combined. The on-the-fly part of the calculation (matching the profile functions to voxel size) of the SRM accounts for 10-30% of the reconstruction time, depending on the number of voxels chosen. We tested our approach with real data from a commercial small animal PET scanner. The results (image quality and reconstruction time) show that the proposed technique is a feasible solution.

  8. Optical tomography reconstruction algorithm with the finite element method: An optimal approach with regularization tools

    Energy Technology Data Exchange (ETDEWEB)

    Balima, O., E-mail: ofbalima@gmail.com [Département des Sciences Appliquées, Université du Québec à Chicoutimi, 555 bd de l’Université, Chicoutimi, QC, Canada G7H 2B1 (Canada); Favennec, Y. [LTN UMR CNRS 6607 – Polytech’ Nantes – La Chantrerie, Rue Christian Pauc, BP 50609 44 306 Nantes Cedex 3 (France); Rousse, D. [Chaire de recherche industrielle en technologies de l’énergie et en efficacité énergétique (t3e), École de technologie supérieure, 201 Boul. Mgr, Bourget Lévis, QC, Canada G6V 6Z3 (Canada)

    2013-10-15

    Highlights: •New strategies to improve the accuracy of the reconstruction through mesh and finite element parameterization. •Use of gradient filtering through an alternative inner product within the adjoint method. •An integral form of the cost function is used to make the reconstruction compatible with all finite element formulations, continuous and discontinuous. •Gradient-based algorithm with the adjoint method is used for the reconstruction. -- Abstract: Optical tomography is mathematically treated as a non-linear inverse problem where the optical properties of the probed medium are recovered through the minimization of the errors between the experimental measurements and their predictions with a numerical model at the locations of the detectors. According to the ill-posed behavior of the inverse problem, some regularization tools must be performed and the Tikhonov penalization type is the most commonly used in optical tomography applications. This paper introduces an optimized approach for optical tomography reconstruction with the finite element method. An integral form of the cost function is used to take into account the surfaces of the detectors and make the reconstruction compatible with all finite element formulations, continuous and discontinuous. Through a gradient-based algorithm where the adjoint method is used to compute the gradient of the cost function, an alternative inner product is employed for preconditioning the reconstruction algorithm. Moreover, appropriate re-parameterization of the optical properties is performed. These regularization strategies are compared with the classical Tikhonov penalization one. It is shown that both the re-parameterization and the use of the Sobolev cost function gradient are efficient for solving such an ill-posed inverse problem.

  9. Estimation of feline renal volume using computed tomography and ultrasound.

    Science.gov (United States)

    Tyson, Reid; Logsdon, Stacy A; Werre, Stephen R; Daniel, Gregory B

    2013-01-01

    Renal volume estimation is an important parameter for clinical evaluation of kidneys and research applications. A time efficient, repeatable, and accurate method for volume estimation is required. The purpose of this study was to describe the accuracy of ultrasound and computed tomography (CT) for estimating feline renal volume. Standardized ultrasound and CT scans were acquired for kidneys of 12 cadaver cats, in situ. Ultrasound and CT multiplanar reconstructions were used to record renal length measurements that were then used to calculate volume using the prolate ellipsoid formula for volume estimation. In addition, CT studies were reconstructed at 1 mm, 5 mm, and 1 cm, and transferred to a workstation where the renal volume was calculated using the voxel count method (hand drawn regions of interest). The reference standard kidney volume was then determined ex vivo using water displacement with the Archimedes' principle. Ultrasound measurement of renal length accounted for approximately 87% of the variability in renal volume for the study population. The prolate ellipsoid formula exhibited proportional bias and underestimated renal volume by a median of 18.9%. Computed tomography volume estimates using the voxel count method with hand-traced regions of interest provided the most accurate results, with increasing accuracy for smaller voxel sizes in grossly normal kidneys (-10.1 to 0.6%). Findings from this study supported the use of CT and the voxel count method for estimating feline renal volume in future clinical and research studies.

  10. Monte-Carlo simulations and image reconstruction for novel imaging scenarios in emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gillam, John E. [The University of Sydney, Faculty of Health Sciences and The Brain and Mind Centre, Camperdown (Australia); Rafecas, Magdalena, E-mail: rafecas@imt.uni-luebeck.de [University of Lubeck, Institute of Medical Engineering, Ratzeburger Allee 160, 23538 Lübeck (Germany)

    2016-02-11

    Emission imaging incorporates both the development of dedicated devices for data acquisition as well as algorithms for recovering images from that data. Emission tomography is an indirect approach to imaging. The effect of device modification on the final image can be understood through both the way in which data are gathered, using simulation, and the way in which the image is formed from that data, or image reconstruction. When developing novel devices, systems and imaging tasks, accurate simulation and image reconstruction allow performance to be estimated, and in some cases optimized, using computational methods before or during the process of physical construction. However, there are a vast range of approaches, algorithms and pre-existing computational tools that can be exploited and the choices made will affect the accuracy of the in silico results and quality of the reconstructed images. On the one hand, should important physical effects be neglected in either the simulation or reconstruction steps, specific enhancements provided by novel devices may not be represented in the results. On the other hand, over-modeling of device characteristics in either step leads to large computational overheads that can confound timely results. Here, a range of simulation methodologies and toolkits are discussed, as well as reconstruction algorithms that may be employed in emission imaging. The relative advantages and disadvantages of a range of options are highlighted using specific examples from current research scenarios.

  11. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice.

  12. Evaluation of the Possibility of Applying Spatial 3D Imaging Using X-Ray Computed Tomography Reconstruction Methods for Quantitative Analysis of Multiphase Materials / Rentgenowska Analiza Ilościowa Materiałów Wielofazowych Z Wykorzystaniem Przestrzennego Obrazowania (3D Przy Użyciu Metod Rekonstrukcji Tomografii Komputerowej

    Directory of Open Access Journals (Sweden)

    Matysik P.

    2015-12-01

    Full Text Available In this paper the possibility of using X-ray computed tomography (CT in quantitative metallographic studies of homogeneous and composite materials is presented. Samples of spheroidal cast iron, Fe-Ti powder mixture compact and epoxy composite reinforced with glass fibers, were subjected to comparative structural tests. Volume fractions of each of the phase structure components were determined by conventional methods with the use of a scanning electron microscopy (SEM and X-ray diffraction (XRD quantitative analysis methods. These results were compared with those obtained by the method of spatial analysis of the reconstructed CT image. Based on the comparative analysis, taking into account the selectivity of data verification methods and the accuracy of the obtained results, the authors conclude that the method of computed tomography is suitable for quantitative analysis of several types of structural materials.

  13. Fast direct reconstruction strategy of dynamic fluorescence molecular tomography using graphics processing units

    Science.gov (United States)

    Chen, Maomao; Zhang, Jiulou; Cai, Chuangjian; Gao, Yang; Luo, Jianwen

    2016-06-01

    Dynamic fluorescence molecular tomography (DFMT) is a valuable method to evaluate the metabolic process of contrast agents in different organs in vivo, and direct reconstruction methods can improve the temporal resolution of DFMT. However, challenges still remain due to the large time consumption of the direct reconstruction methods. An acceleration strategy using graphics processing units (GPU) is presented. The procedure of conjugate gradient optimization in the direct reconstruction method is programmed using the compute unified device architecture and then accelerated on GPU. Numerical simulations and in vivo experiments are performed to validate the feasibility of the strategy. The results demonstrate that, compared with the traditional method, the proposed strategy can reduce the time consumption by ˜90% without a degradation of quality.

  14. A novel dual-axis reconstruction algorithm for electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Jenna; Midgley, Paul [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge, CB2 3QZ (United Kingdom)

    2006-02-22

    A new algorithm for computing electron microscopy tomograms which combines iterative methods with dual-axis geometry is presented. Initial modelling using test data shows several improvements over both the weighted back-projection (WBP) and Simultaneous Iterative Reconstruction Technique (SIRT) method, and, with increased stability and tomogram fidelity under high-noise conditions.

  15. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  16. A constrained conjugate gradient algorithm for computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, S.G.; Goodman, D.M. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Image reconstruction from projections of x-ray, gamma-ray, protons and other penetrating radiation is a well-known problem in a variety of fields, and is commonly referred to as computed tomography (CT). Various analytical and series expansion methods of reconstruction and been used in the past to provide three-dimensional (3D) views of some interior quantity. The difficulties of these approaches lie in the cases where (a) the number of views attainable is limited, (b) the Poisson (or other) uncertainties are significant, (c) quantifiable knowledge of the object is available, but not implementable, or (d) other limitations of the data exist. We have adapted a novel nonlinear optimization procedure developed at LLNL to address limited-data image reconstruction problems. The technique, known as nonlinear least squares with general constraints or constrained conjugate gradients (CCG), has been successfully applied to a number of signal and image processing problems, and is now of great interest to the image reconstruction community. Previous applications of this algorithm to deconvolution problems and x-ray diffraction images for crystallography have shown the great promise.

  17. Optimisation and validation of a 3D reconstruction algorithm for single photon emission computed tomography by means of GATE simulation platform; Optimisation et validation d'un algorithme de reconstruction 3D en Tomographie d'Emission Monophotonique a l'aide de la plate forme de simulation GATE

    Energy Technology Data Exchange (ETDEWEB)

    El Bitar, Ziad [Ecole Doctorale des Sciences Fondamentales, Universite Blaise Pascal, U.F.R de Recherches Scientifiques et Techniques, 34, avenue Carnot - BP 185, 63006 Clermont-Ferrand Cedex (France); Laboratoire de Physique Corpusculaire, CNRS/IN2P3, 63177 Aubiere (France)

    2006-12-15

    Although time consuming, Monte-Carlo simulations remain an efficient tool enabling to assess correction methods for degrading physical effects in medical imaging. We have optimized and validated a reconstruction method baptized F3DMC (Fully 3D Monte Carlo) in which the physical effects degrading the image formation process were modelled using Monte-Carlo methods and integrated within the system matrix. We used the Monte-Carlo simulation toolbox GATE. We validated GATE in SPECT by modelling the gamma-camera (Philips AXIS) used in clinical routine. Techniques of threshold, filtering by a principal component analysis and targeted reconstruction (functional regions, hybrid regions) were used in order to improve the precision of the system matrix and to reduce the number of simulated photons as well as the time consumption required. The EGEE Grid infrastructures were used to deploy the GATE simulations in order to reduce their computation time. Results obtained with F3DMC were compared with the reconstruction methods (FBP, ML-EM, MLEMC) for a simulated phantom and with the OSEM-C method for the real phantom. Results have shown that the F3DMC method and its variants improve the restoration of activity ratios and the signal to noise ratio. By the use of the grid EGEE, a significant speed-up factor of about 300 was obtained. These results should be confirmed by performing studies on complex phantoms and patients and open the door to a unified reconstruction method, which could be used in SPECT and also in PET. (author)

  18. 3D ultrasound computer tomography: update from a clinical study

    Science.gov (United States)

    Hopp, T.; Zapf, M.; Kretzek, E.; Henrich, J.; Tukalo, A.; Gemmeke, H.; Kaiser, C.; Knaudt, J.; Ruiter, N. V.

    2016-04-01

    Ultrasound Computer Tomography (USCT) is a promising new imaging method for breast cancer diagnosis. We developed a 3D USCT system and tested it in a pilot study with encouraging results: 3D USCT was able to depict two carcinomas, which were present in contrast enhanced MRI volumes serving as ground truth. To overcome severe differences in the breast shape, an image registration was applied. We analyzed the correlation between average sound speed in the breast and the breast density estimated from segmented MRIs and found a positive correlation with R=0.70. Based on the results of the pilot study we now carry out a successive clinical study with 200 patients. For this we integrated our reconstruction methods and image post-processing into a comprehensive workflow. It includes a dedicated DICOM viewer for interactive assessment of fused USCT images. A new preview mode now allows intuitive and faster patient positioning. We updated the USCT system to decrease the data acquisition time by approximately factor two and to increase the penetration depth of the breast into the USCT aperture by 1 cm. Furthermore the compute-intensive reflectivity reconstruction was considerably accelerated, now allowing a sub-millimeter volume reconstruction in approximately 16 minutes. The updates made it possible to successfully image first patients in our ongoing clinical study.

  19. Enhancement of photoacoustic tomography in the tissue with speed-of-sound variance using ultrasound computed tomography

    Institute of Scientific and Technical Information of China (English)

    程任翔; 陶超; 刘晓峻

    2015-01-01

    The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo-geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed to-mography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography.

  20. Computational Techniques in Radio Neutrino Event Reconstruction

    Science.gov (United States)

    Beydler, M.; ARA Collaboration

    2016-03-01

    The Askaryan Radio Array (ARA) is a high-energy cosmic neutrino detector constructed with stations of radio antennas buried in the ice at the South Pole. Event reconstruction relies on the analysis of the arrival times of the transient radio signals generated by neutrinos interacting within a few kilometers of the detector. Because of its depth dependence, the index of refraction in the ice complicates the interferometric directional reconstruction of possible neutrino events. Currently, there is an ongoing endeavor to enhance the programs used for the time-consuming computations of the curved paths of the transient wave signals in the ice as well as the interferometric beamforming. We have implemented a fast, multi-dimensional spline table lookup of the wave arrival times in order to enable raytrace-based directional reconstructions. Additionally, we have applied parallel computing across multiple Graphics Processing Units (GPUs) in order to perform the beamforming calculations quickly.

  1. Facial reconstruction using 3-D computer graphics.

    Science.gov (United States)

    Vanezi, P; Vanezis, M; McCombe, G; Niblett, T

    2000-02-14

    Facial reconstruction using 3-D computer graphics is being used in our institute as a routine procedure in forensic cases as well as for skulls of historical and archaeological interest. Skull and facial data from living subjects is acquired using an optical laser scanning system. For the production of the reconstructed image, we employ facial reconstruction software which is constructed using the TCL/Tk scripting language, the latter making use of the C3D system. The computer image may then be exported to enable the production of a solid model, employing, for example, stereolithography. The image can also be modified within an identikit system which allows the addition of facial features as appropriate.

  2. Computational methods for three-dimensional microscopy reconstruction

    CERN Document Server

    Frank, Joachim

    2014-01-01

    Approaches to the recovery of three-dimensional information on a biological object, which are often formulated or implemented initially in an intuitive way, are concisely described here based on physical models of the object and the image-formation process. Both three-dimensional electron microscopy and X-ray tomography can be captured in the same mathematical framework, leading to closely-related computational approaches, but the methodologies differ in detail and hence pose different challenges. The editors of this volume, Gabor T. Herman and Joachim Frank, are experts in the respective methodologies and present research at the forefront of biological imaging and structural biology.   Computational Methods for Three-Dimensional Microscopy Reconstruction will serve as a useful resource for scholars interested in the development of computational methods for structural biology and cell biology, particularly in the area of 3D imaging and modeling.

  3. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  4. CORONARY ANGIOGRAPHY WITH DUAL SOURCE COMPUTED TOMOGRAPHY: INITIAL EXPERIENCE

    Institute of Scientific and Technical Information of China (English)

    Zhu-hua Zhang; Wen-min Zhao; Wen-bin Mou; Li-ren Zhang; Wen-ling Zhu; Qi Miao; Qi Fang; Zheng-yu Jin; Shu-yang Zhang; Song-bai Lin; Dong-jing Li; Ling-yan Kong; Yi-ning Wang; Lan Song; Yun Wang

    2007-01-01

    To explore the scan technique and image quality of coronary angiography with dual source computed tomography (CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients. Calcium scoring with plain scan images as well as multi-planar reconstruction( MPR ), maximum intensity projection (MIP), and volume rendering technique (VRT) reconstruction with enhanced scan images were performed in all cases. The scan technique and post-reconstruction experience was summarized. The image quality was classified as 1 to 4 points, and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6 ± 298.7 (0-3 216. 5). The average heart rate of the enhanced scan was 82.1 ± 16.2 (47-139) bpm. The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method, two or more phases supplemented method, and electrocardiogram editing method. Altogether 8 457 coronary segments were evaluated, among which 97.2% were evaluated as point 1, 1.7% point 2, 0.5% point 3, and0.6% point 4. The coronary segments in 261 cases were completely normal, while 360 segments were diagnosed with < 50% stenosis and 625 segments with ≥50%stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation. Heart rate is not a major source of the artifact, coronary segments can be well shown with single or multiple-phase reconstruction method.

  5. Image reconstruction of fluorescent molecular tomography based on the tree structured Schur complement decomposition

    Directory of Open Access Journals (Sweden)

    Wang Jiajun

    2010-05-01

    Full Text Available Abstract Background The inverse problem of fluorescent molecular tomography (FMT often involves complex large-scale matrix operations, which may lead to unacceptable computational errors and complexity. In this research, a tree structured Schur complement decomposition strategy is proposed to accelerate the reconstruction process and reduce the computational complexity. Additionally, an adaptive regularization scheme is developed to improve the ill-posedness of the inverse problem. Methods The global system is decomposed level by level with the Schur complement system along two paths in the tree structure. The resultant subsystems are solved in combination with the biconjugate gradient method. The mesh for the inverse problem is generated incorporating the prior information. During the reconstruction, the regularization parameters are adaptive not only to the spatial variations but also to the variations of the objective function to tackle the ill-posed nature of the inverse problem. Results Simulation results demonstrate that the strategy of the tree structured Schur complement decomposition obviously outperforms the previous methods, such as the conventional Conjugate-Gradient (CG and the Schur CG methods, in both reconstruction accuracy and speed. As compared with the Tikhonov regularization method, the adaptive regularization scheme can significantly improve ill-posedness of the inverse problem. Conclusions The methods proposed in this paper can significantly improve the reconstructed image quality of FMT and accelerate the reconstruction process.

  6. PDE regularization for Bayesian reconstruction of emission tomography

    Science.gov (United States)

    Wang, Zhentian; Zhang, Li; Xing, Yuxiang; Zhao, Ziran

    2008-03-01

    The aim of the present study is to investigate a type of Bayesian reconstruction which utilizes partial differential equations (PDE) image models as regularization. PDE image models are widely used in image restoration and segmentation. In a PDE model, the image can be viewed as the solution of an evolutionary differential equation. The variation of the image can be regard as a descent of an energy function, which entitles us to use PDE models in Bayesian reconstruction. In this paper, two PDE models called anisotropic diffusion are studied. Both of them have the characteristics of edge-preserving and denoising like the popular median root prior (MRP). We use PDE regularization with an Ordered Subsets accelerated Bayesian one step late (OSL) reconstruction algorithm for emission tomography. The OS accelerated OSL algorithm is more practical than a non-accelerated one. The proposed algorithm is called OSEM-PDE. We validated the OSEM-PDE using a Zubal phantom in numerical experiments with attenuation correction and quantum noise considered, and the results are compared with OSEM and an OS version of MRP (OSEM-MRP) reconstruction. OSEM-PDE shows better results both in bias and variance. The reconstruction images are smoother and have sharper edges, thus are more applicable for post processing such as segmentation. We validate this using a k-means segmentation algorithm. The classic OSEM is not convergent especially in noisy condition. However, in our experiment, OSEM-PDE can benefit from OS acceleration and keep stable and convergent while OSEM-MRP failed to converge.

  7. Quantifying the debonding of inclusions through tomography and computational homology.

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Yang; Johnson, George C. (University of California, Berkeley, Berkeley, CA); Mota, Alejandro; Foulk, James W., III; Jin, Huiqing

    2010-09-01

    This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

  8. A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Knesaurek, K. [Div. of Nuclear Medicine and Neuroscience PET Lab., Mount Sinai Medical Center, New York, NY (United States); Machac, J. [Div. of Nuclear Medicine and Neuroscience PET Lab., Mount Sinai Medical Center, New York, NY (United States); Vallabhajosula, S. [Div. of Nuclear Medicine and Neuroscience PET Lab., Mount Sinai Medical Center, New York, NY (United States); Buchsbaum, M.S. [Div. of Nuclear Medicine and Neuroscience PET Lab., Mount Sinai Medical Center, New York, NY (United States)

    1996-06-01

    A new interative reconstruction technique (NIRT) for positron emission computed tomography (PET), which uses transmission data for nonuniform attenuation correction, is described. Utilizing the general inverse problem theory, a cost functional which includes a noise term was derived. The cost functional was minimized using a weighted-least-square maximum a posteriori conjugate gradient (CG) method. The procedure involves a change in the Hessian of the cost function by adding an additional term. Two phantoms were used in a real data acquisition. The first was a cylinder phantom filled with uniformly distributed activity of 74 MBq of fluorine-18. Two different inserts were placed in the phantom. The second was a Hoffman brain phantom filled with uniformly distributed activity of 7.4 MBq of {sup 18}F. Resulting reconstructed images were used to test and compare a new interative reconstruction technique with a standard filtered backprojection (FBP) method. The results confirmed that NIRT, based on the conjugate gradient method, converges rapidly and provides good reconstructed images. In comaprison with standard results obtained by the FBP method, the images reconstructed by NIRT showed better noise properties. The noise was measured as rms% noise and was less, by a factor of 1.75, in images reconstructed by NIRT than in the same images reconstructed by FBP. The distance between the Hoffman brain slice created from the MRI image was 0.526, while the same distance for the Hoffman brain slice reconstructed by NIRT was 0.328. The NIRT method suppressed the propagation of the noise without visible loss of resolution in the reconstructed PET images. (orig.)

  9. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  10. Computed tomography in neuronal ceroid lipofuscinosis

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neuronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter.

  11. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...... measurement uncertainties in the range 1.5–5.5 μm, showing a good stability over the 6 months of the circulation. The comparison has shown that CT measurements on the industrial parts used lie in the range 6–53 μm, with maximum values up to 158 μm....

  12. Tomography and spectroscopy as quantum computations

    CERN Document Server

    Miquel, C; Saraceno, M; Knill, E H; Laflamme, R; Negrevergne, C; Miquel, Cesar; Paz, Juan Pablo; Saraceno, Marcos; Knill, Emmanuel; Laflamme, Raymond; Negrevergne, Camille

    2001-01-01

    Determining the state of a system and measuring properties of its evolution are two of the most important tasks a physicist faces. For the first purpose one can use tomography, a method that after subjecting the system to a number of experiments determines all independent elements of the density matrix. For the second task, one can resort to spectroscopy, a set of techniques used to determine the spectrum of eigenvalues of the evolution operator. In this letter, we show that tomography and spectroscopy can be naturally interpreted as dual forms of quantum computation. We show how to adapt the simplest case of the well-known phase estimation quantum algorithm to perform both tasks, giving it a natural interpretation as a simulated scattering experiment. We show how this algorithm can be used to implement an interesting form of tomography by performing a direct measurement of the Wigner function of a quantum system. We present results of such measurements performed on a system of three qubits using liquid state...

  13. The first demonstration of laser computed tomography achieved by Coherent Detection Imaging method for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Toida, Masahiro; Ichimura, Tsutomu (Research Development Corp. of Japan (JRDC), Sendai (Japan). Inaba Biophoton Project); Inaba, Humio

    1991-06-01

    The first successful imaging by laser absorption computed tomography of in vitro specimens has been achieved by means of the Coherent Detection Imaging (CDI) method realized with the optical heterodyne detection technique and image reconstruction from back projection of the data obtained via optical absorption measurements in a parallel beam geometry. (author).

  14. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Science.gov (United States)

    Liu, Yubin; Wang, Yating

    2016-01-01

    We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT) system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases. PMID:27774453

  15. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Directory of Open Access Journals (Sweden)

    Yubin Liu

    2016-01-01

    Full Text Available We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases.

  16. Reconstruction of an InAs nanowire using geometric and algebraic tomography

    DEFF Research Database (Denmark)

    Pennington, Robert S.; König, S.; Alpers, A.;

    2011-01-01

    Geometric tomography and conventional algebraic tomography algorithms are used to reconstruct cross-sections of an InAs nanowire from a tilt series of experimental annular dark-field images. Both algorithms are also applied to a test object to assess what factors affect the reconstruction quality...

  17. 3D reconstruction for partial data electrical impedance tomography using a sparsity prior

    DEFF Research Database (Denmark)

    Garde, Henrik; Knudsen, Kim

    2015-01-01

    In electrical impedance tomography the electrical conductivity inside a physical body is computed from electro-static boundary measurements. The focus of this paper is to extend recent results for the 2D problem to 3D: prior information about the sparsity and spatial distribution...... of the conductivity is used to improve reconstructions for the partial data problem with Cauchy data measured only on a subset of the boundary. A sparsity prior is enforced using the ℓ1 norm in the penalty term of a Tikhonov functional, and spatial prior information is incorporated by applying a spatially distributed...

  18. Individual thorax geometry reduces position and size differences in reconstructed images of electrical impedance tomography.

    Science.gov (United States)

    Zhao, Zhanqi; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich; Möller, Knut

    2014-01-01

    Due to the ill-posed problem, the electrical impedance within the thorax cannot be exactly reconstructed. The aim of our study was to prove that reconstruction with individual thorax geometry improved the quality of EIT (electrical impedance tomography) images. Seven mechanically ventilated patients with acute respiratory distress syndrome were examined by EIT. The thorax contours were determined from routine computed tomography (CT) images based on automatic threshold filtering. EIT raw data was reconstructed offline with (1) back-projection with circular forward model; (2) GREIT reconstruction method with circular forward model and (3) GREIT with individual thorax geometry. The resulting EIT images were compared to rescaled CT images. The distance between the lung contour and the thorax contour was calculated for each method and the differences to that in CT were denoted as position differences. Shape differences was defined as the ratio of thorax (or lungs) size in EIT and that in rescaled CT. Method (3) has the smallest position differences (6.6 ± 2.8, 5.3 ± 3.3, 2.3 ± 1.4 in pixel, for each reconstruction method respectively; mean ± SD). The thorax and lungs sizes in the transformed CT images were 514 ± 73 and 177 ± 39. Shape differences of thorax were 1.81 ± 0.26, 1.81 ± 0.26, 1.10 ± 0.12 and that of lungs were 1.69 ± 0.45, 1.52 ± 0.45, 1.34 ± 0.35 for each method respectively. The reconstructed images using the GREIT method with individual thorax geometry were more realistic. Improvement of EIT image quality may foster the acceptance of EIT in routine clinical use.

  19. COMPUTED TOMOGRAPHY OF TOOTH RESORPTION IN CATS.

    Science.gov (United States)

    Lang, Linda G; Wilkinson, Thomas E; White, Tammy L; Farnsworth, Raelynn K; Potter, Kathleen A

    2016-09-01

    Tooth resorption is the most common dental disease in cats and can be a source of oral pain. The current clinical gold standard for diagnosis includes a combination of oral exam and dental radiography, however early lesions are not always detected. Computed tomography (CT) of the skull, including the dental arches, is a commonly performed diagnostic procedure, however the appearance of tooth resorption on CT and the diagnostic ability of CT to detect tooth resorption have not been evaluated. The purpose of this prospective, descriptive, diagnostic accuracy study was to characterize the CT appearance of tooth resorption in a sample of affected cats and to evaluate the sensitivity and specificity of CT for tooth resorption compared to the clinical gold standard of oral exam and intraoral dental radiography. Twenty-eight cat cadaver specimens were recruited for inclusion. Each specimen was evaluated using oral exam, intraoral dental radiography, and computed tomography (four different slice thicknesses). Each tooth was evaluated for the presence or absence of tooth resorption. Teeth with lesions and a subset of normal teeth were evaluated with histopathology. On CT, tooth resorption appeared as irregularly marginated hypoattenuating defects in the mineral attenuating tooth components, most commonly involving the root or cementoenamel junction. Sensitivity for CT detection of tooth resorption was fair to poor (42.2-57.7%) and specificity was good to excellent (92.8-96.3%). Findings from this study indicated that CT has high specificity but low sensitivity for detection of tooth resorption in cats.

  20. Computed tomography in pelvic and acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Born, H.; Schmidt, C.

    1988-06-01

    In a retrospective study we analyzed the results of 127 patients, who were examined not only by means of conventional radiography but also by means of computed tomography after a trauma of the pelvic. Our investigations were based upon such patients, to whom a definite diagnostic procedure of plain radiography had been performed. Therefore all polytraumatized patients were inapplicable. They were only examined by computed tomography because of other more important accompanying injuries of other body regions. We compared the results of 127 patients with pelvic trauma. The results of the CT were in accordance with the results of the plain radiography for 103 patients. The results of the CT concerning the availability and the localization of the fractures were basically coincident with the plain radiography for 22 patients, but the CT showed a higher degree of trauma and additional intraarticular fragments. Two isolated lesions of the sacroiliac joint could not be recognized by both methods. They could only be diagnosed by bone scintigraphy on the third day after trauma.

  1. SU-E-I-12: Flexible Geometry Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, R [East Lansing, MI (United States)

    2015-06-15

    Purpose: The concept separates the mechanical connection between the radiation source and detector. This design allows the trajectory and orientation of the radiation source/detector to be customized to the object that is being imaged. This is in contrast to the formulaic rotation-translation image acquisition of conventional computed tomography(CT).Background/significance:CT devices that image a full range of: anatomy, patient populations, and imaging procedures are large. The root cause of the expanding size of comprehensive CT is due to the commitment to helical geometry that is hardwired into the image reconstruction. FGCT extends the application of alternative reconstruction techniques, i.e. tomosynthesis, by separating the two main components— radiation source and detector— and allow for 6 degrees of freedom motion for radiation source, detector, or both. The image acquisition geometry is then tailored to how the patient/object is positioned. This provides greater flexibility on the position and location that the patient/object is being imaged. Additionally, removing the need of a rotating gantry reduces the footprint so that CT is more mobile and more available to move to where the patient/object is at, instead of the other way around. Methods: As proof-of-principle, a reconstruction algorithm is designed to produce FGCT images. Using simulated detector data, voxels intersecting a line drawn between the radiation source and an individual detector are traced and modified using the detector signal. The detector signal is modified to compensate for changes in the source to detector distance. Adjacent voxels are modified in proportion to the detector signal, providing a simple image filter. Results: Image-quality from the proposed FGCT reconstruction technique is proving to be a challenge, producing hardily recognizable images from limited projections angles. Conclusion: Preliminary assessment of the reconstruction technique demonstrates the inevitable

  2. SADMFR guidelines for the use of cone-beam computed tomography/ Digital Volume Tomography

    OpenAIRE

    Dula, Karl; Bornstein, Michael M.; Buser, Daniel; Dagassan-Berndt, Dorothea; Ettlin, Dominik A; Filippi, Andreas; Gabioud, François; Katsaros, Christos; Krastl, Gabriel; Lambrecht, J. Thomas; Lauber, Roland; Luebbers, Heinz-Theo; Pazera, Pawel; Türp, Jens C.

    2014-01-01

    Cone-Beam Computed Tomography (CBCT) has been introduced in 1998. This radiological imaging procedure has been provided for dentistry and is comparable to computed tomography (CT) in medicine. It is expected that CBCT will have the same success in dental diagnostic imaging as computed tomography had in medicine. Just as CT is responsible for a significant rise in radiation dose to the population from medical X-ray diagnostics, CBCT studies will be accompanied by a significant increase of the ...

  3. Some Nonlinear Reconstruction Algorithms for Electrical Impedance Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Berryman, J G

    2001-03-09

    An impedance camera [Henderson and Webster, 1978; Dines and Lytle, 1981]--or what is now more commonly called electrical impedance tomography--attempts to image the electrical impedance (or just the conductivity) distribution inside a body using electrical measurements on its boundary. The method has been used successfully in both biomedical [Brown, 1983; Barber and Brown, 1986; J. C. Newell, D. G. Gisser, and D. Isaacson, 1988; Webster, 1990] and geophysical applications [Wexler, Fry, and Neurnan, 1985; Daily, Lin, and Buscheck, 1987], but the analysis of optimal reconstruction algorithms is still progressing [Murai and Kagawa, 1985; Wexler, Fry, and Neurnan, 1985; Kohn and Vogelius, 1987; Yorkey and Webster, 1987; Yorkey, Webster, and Tompkins, 1987; Berryman and Kohn, 1990; Kohn and McKenney, 1990; Santosa and Vogelius, 1990; Yorkey, 1990]. The most common application is monitoring the influx or efflux of a highly conducting fluid (such as brine in a porous rock or blood in the human body) through the volume being imaged. For biomedical applications, this met hod does not have the resolution of radiological methods, but it is comparatively safe and inexpensive and therefore provides a valuable alternative when continuous monitoring of a patient or process is desired. The following discussion is intended first t o summarize the physics of electrical impedance tomography, then to provide a few details of the data analysis and forward modeling requirements, and finally to outline some of the reconstruction algorithms that have proven to be most useful in practice. Pointers to the literature are provided throughout this brief narrative and the reader is encouraged to explore the references for more complete discussions of the various issues raised here.

  4. Use of cone beam computed tomography in periodontology.

    Science.gov (United States)

    Acar, Buket; Kamburoğlu, Kıvanç

    2014-05-28

    Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography (CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  5. Computed Tomography Technology: Development and Applications for Defence

    Science.gov (United States)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-09-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT&E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  6. Computational Imaging for VLBI Image Reconstruction

    CERN Document Server

    Bouman, Katherine L; Zoran, Daniel; Fish, Vincent L; Doeleman, Sheperd S; Freeman, William T

    2015-01-01

    Very long baseline interferometry (VLBI) is a technique for imaging celestial radio emissions by simultaneously observing a source from telescopes distributed across Earth. The challenges in reconstructing images from fine angular resolution VLBI data are immense. The data is extremely sparse and noisy, thus requiring statistical image models such as those designed in the computer vision community. In this paper we present a novel Bayesian approach for VLBI image reconstruction. While other methods require careful tuning and parameter selection for different types of images, our method is robust and produces good results under different settings such as low SNR or extended emissions. The success of our method is demonstrated on realistic synthetic experiments as well as publicly available real data. We present this problem in a way that is accessible to members of the computer vision community, and provide a dataset website (vlbiimaging.csail.mit.edu) to allow for controlled comparisons across algorithms. Thi...

  7. Filter assessment applied to analytical reconstruction for industrial third-generation tomography

    Energy Technology Data Exchange (ETDEWEB)

    Velo, Alexandre F.; Martins, Joao F.T.; Oliveira, Adriano S.; Carvalho, Diego V.S.; Faria, Fernando S.; Hamada, Margarida M.; Mesquita, Carlos H., E-mail: afvelo@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Multiphase systems are structures that contain a mixture of solids, liquids and gases inside a chemical reactor or pipes in a dynamic process. These systems are found in chemical, food, pharmaceutical and petrochemical industries. The gamma ray computed tomography (CT) system has been applied to visualize the distribution of multiphase systems without interrupting production. CT systems have been used to improve design, operation and troubleshooting of industrial processes. Computer tomography for multiphase processes is being developed at several laboratories. It is well known that scanning systems demand high processing time, limited set of data projections and views to obtain an image. Because of it, the image quality is dependent on the number of projection, number of detectors, acquisition time and reconstruction time. A phantom containing air, iron and aluminum was used on the third generation industrial tomography with 662 keV ({sup 137}Cs) radioactive source. It was applied the Filtered Back Projection algorithm to reconstruct the images. An efficient tomography is dependent of the image quality, thus the objective of this research was to apply different types of filters on the analytical algorithm and compare each other using the figure of merit denominated root mean squared error (RMSE), the filter that presents lower value of RMSE has better quality. On this research, five types of filters were used: Ram-Lak, Shepp-Logan, Cosine, Hamming and Hann filters. As results, all filters presented lower values of RMSE, that means the filters used have low stand deviation compared to the mass absorption coefficient, however, the Hann filter presented better RMSE and CNR compared to the others. (author)

  8. Graphics processing unit (GPU)-accelerated particle filter framework for positron emission tomography image reconstruction.

    Science.gov (United States)

    Yu, Fengchao; Liu, Huafeng; Hu, Zhenghui; Shi, Pengcheng

    2012-04-01

    As a consequence of the random nature of photon emissions and detections, the data collected by a positron emission tomography (PET) imaging system can be shown to be Poisson distributed. Meanwhile, there have been considerable efforts within the tracer kinetic modeling communities aimed at establishing the relationship between the PET data and physiological parameters that affect the uptake and metabolism of the tracer. Both statistical and physiological models are important to PET reconstruction. The majority of previous efforts are based on simplified, nonphysical mathematical expression, such as Poisson modeling of the measured data, which is, on the whole, completed without consideration of the underlying physiology. In this paper, we proposed a graphics processing unit (GPU)-accelerated reconstruction strategy that can take both statistical model and physiological model into consideration with the aid of state-space evolution equations. The proposed strategy formulates the organ activity distribution through tracer kinetics models and the photon-counting measurements through observation equations, thus making it possible to unify these two constraints into a general framework. In order to accelerate reconstruction, GPU-based parallel computing is introduced. Experiments of Zubal-thorax-phantom data, Monte Carlo simulated phantom data, and real phantom data show the power of the method. Furthermore, thanks to the computing power of the GPU, the reconstruction time is practical for clinical application.

  9. Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography.

    Science.gov (United States)

    Saha, Krishnendu; Straus, Kenneth J; Chen, Yu; Glick, Stephen J

    2014-08-28

    To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

  10. Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Krishnendu [Ohio Medical Physics Consulting, Dublin, Ohio 43017 (United States); Straus, Kenneth J.; Glick, Stephen J. [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States); Chen, Yu. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States)

    2014-08-28

    To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

  11. Micro-computed tomography for small animal imaging: Technological details

    Institute of Scientific and Technical Information of China (English)

    Hao Li; Hui Zhang; Zhiwei Tang; Guangshu Hu

    2008-01-01

    The high-resolution micro-computed tomography(micro-CT)system has now become an important tool for biological research.The micro-CT system enables a non-invasive inspection to screen anatomical changes in small animals.The promising advantages include high-spatial resolution,high sensitivity to bone and lung,short scan time and cost-effectiveness.The dose received by the small animal might be a critical concern in the research.In this article,the choice of the components,fundamental physical problems,the image reconstruction algorithm and the representative applications of micro-CT are summarized.Some results from our research group are also presented to show high-resolution images obtained by the micro-CT system.

  12. Glasses for 3D ultrasound computer tomography: phase compensation

    Science.gov (United States)

    Zapf, M.; Hopp, T.; Ruiter, N. V.

    2016-03-01

    Ultrasound Computer Tomography (USCT), developed at KIT, is a promising new imaging system for breast cancer diagnosis, and was successfully tested in a pilot study. The 3D USCT II prototype consists of several hundreds of ultrasound (US) transducers on a semi-ellipsoidal aperture. Spherical waves are sequentially emitted by individual transducers and received in parallel by many transducers. Reflectivity volumes are reconstructed by synthetic aperture focusing (SAFT). However, straight forward SAFT imaging leads to blurred images due to system imperfections. We present an extension of a previously proposed approach to enhance the images. This approach includes additional a priori information and system characteristics. Now spatial phase compensation was included. The approach was evaluated with a simulation and clinical data sets. An increase in the image quality was observed and quantitatively measured by SNR and other metrics.

  13. Inspection of a Medieval Wood Sculpture Using Computer Tomography

    Science.gov (United States)

    Kapitany, K.; Somogyi, A.; Barsi, A.

    2016-06-01

    Computer tomography (CT) is an excellent technique for obtaining accurate 3D information about the human body. It allows to visualize the organs, bones and blood vessels, furthermore it enables to diagnose anomalies and diseases. Its spatial reconstruction capability supports other interesting applications, such as inspecting different, even valuable objects like ancient sculptures. Current paper presents a methodology of evaluating CT and video imagery through the example of investigating a wood Madonna with infant Jesus sculpture from the 14th century. The developed techniques extract the outer boundary of the statue, which has been triangulated to derive the surface model. The interior of the sculpture has also been revealed: the iron bolts and rivets as well as the woodworm holes can be mapped. By merging the interior and outer data (geometry and texture) interesting visualizations (perspective views, sections etc.) have been created.

  14. Application of cone beam computed tomography in facial imaging science

    Institute of Scientific and Technical Information of China (English)

    Zacharias Fourie; Janalt Damstra; Yijin Ren

    2012-01-01

    The use of three-dimensional (3D) methods for facial imaging has increased significantly over the past years.Traditional 2D imaging has gradually being replaced by 3D images in different disciplines,particularly in the fields of orthodontics,maxillofacial surgery,plastic and reconstructive surgery,neurosurgery and forensic sciences.In most cases,3D facial imaging overcomes the limitations of traditional 2D methods and provides the clinician with more accurate information regarding the soft-tissues and the underlying skeleton.The aim of this study was to review the types of imaging methods used for facial imaging.It is important to realize the difference between the types of 3D imaging methods as application and indications thereof may differ.Since 3D cone beam computed tomography (CBCT) imaging will play an increasingly importanl role in orthodontics and orthognathic surgery,special emphasis should be placed on discussing CBCT applications in facial evaluations.

  15. Incorporating MRI structural information into bioluminescence tomography: system, heterogeneous reconstruction and in vivo quantification.

    Science.gov (United States)

    Zhang, Jun; Chen, Duofang; Liang, Jimin; Xue, Huadan; Lei, Jing; Wang, Qin; Chen, Dongmei; Meng, Ming; Jin, Zhengyu; Tian, Jie

    2014-06-01

    Combining two or more imaging modalities to provide complementary information has become commonplace in clinical practice and in preclinical and basic biomedical research. By incorporating the structural information provided by computed tomography (CT) or magnetic resonance imaging (MRI), the ill poseness nature of bioluminescence tomography (BLT) can be reduced significantly, thus improve the accuracies of reconstruction and in vivo quantification. In this paper, we present a small animal imaging system combining multi-view and multi-spectral BLT with MRI. The independent MRI-compatible optical device is placed at the end of the clinical MRI scanner. The small animal is transferred between the light tight chamber of the optical device and the animal coil of MRI via a guide rail during the experiment. After the optical imaging and MRI scanning procedures are finished, the optical images are mapped onto the MRI surface by interactive registration between boundary of optical images and silhouette of MRI. Then, incorporating the MRI structural information, a heterogeneous reconstruction algorithm based on finite element method (FEM) with L 1 normalization is used to reconstruct the position, power and region of the light source. In order to validate the feasibility of the system, we conducted experiments of nude mice model implanted with artificial light source and quantitative analysis of tumor inoculation model with MDA-231-GFP-luc. Preliminary results suggest the feasibility and effectiveness of the prototype system.

  16. Use of high-resolution computed tomography and positron emission tomography/computed tomography in the management of stage IA adenocarcinoma.

    Science.gov (United States)

    Miyata, Yoshihiro; Tsutani, Yasuhiro; Okada, Morihito

    2012-01-01

    Preoperative determination of malignant behavior is critical in choosing suitable therapeutic strategies such as sublobar resection for patients with small lung cancers. The aim of present review was to evaluate high-resolution computed tomography and fluorodeoxyglucose-positron emission tomography/computed tomography as tools for management of clinical stage IA adenocarcinoma.

  17. Tensor-based dynamic reconstruction method for electrical capacitance tomography

    Science.gov (United States)

    Lei, J.; Mu, H. P.; Liu, Q. B.; Li, Z. H.; Liu, S.; Wang, X. Y.

    2017-03-01

    Electrical capacitance tomography (ECT) is an attractive visualization measurement method, in which the acquisition of high-quality images is beneficial for the understanding of the underlying physical or chemical mechanisms of the dynamic behaviors of the measurement objects. In real-world measurement environments, imaging objects are often in a dynamic process, and the exploitation of the spatial-temporal correlations related to the dynamic nature will contribute to improving the imaging quality. Different from existing imaging methods that are often used in ECT measurements, in this paper a dynamic image sequence is stacked into a third-order tensor that consists of a low rank tensor and a sparse tensor within the framework of the multiple measurement vectors model and the multi-way data analysis method. The low rank tensor models the similar spatial distribution information among frames, which is slowly changing over time, and the sparse tensor captures the perturbations or differences introduced in each frame, which is rapidly changing over time. With the assistance of the Tikhonov regularization theory and the tensor-based multi-way data analysis method, a new cost function, with the considerations of the multi-frames measurement data, the dynamic evolution information of a time-varying imaging object and the characteristics of the low rank tensor and the sparse tensor, is proposed to convert the imaging task in the ECT measurement into a reconstruction problem of a third-order image tensor. An effective algorithm is developed to search for the optimal solution of the proposed cost function, and the images are reconstructed via a batching pattern. The feasibility and effectiveness of the developed reconstruction method are numerically validated.

  18. Spatiotemporal computed tomography of dynamic processes

    Science.gov (United States)

    Kaestner, Anders; Münch, Beat; Trtik, Pavel; Butler, Les

    2011-12-01

    Modern computed tomography (CT) equipment allowing fast 3-D imaging also makes it possible to monitor dynamic processes by 4-D imaging. Because the acquisition time of various 3-D-CT systems is still in the range of at least milliseconds or even hours, depending on the detector system and the source, the balance of the desired temporal and spatial resolution must be adjusted. Furthermore, motion artifacts will occur, especially at high spatial resolution and longer measuring times. We propose two approaches based on nonsequential projection angle sequences allowing a convenient postacquisition balance of temporal and spatial resolution. Both strategies are compatible with existing instruments, needing only a simple reprograming of the angle list used for projection acquisition and care with the projection order list. Both approaches will reduce the impact of artifacts due to motion. The strategies are applied and validated with cold neutron imaging of water desorption from originally saturated particles during natural air-drying experiments and with x-ray tomography of a polymer blend heated during imaging.

  19. Model Based Iterative Reconstruction for Bright Field Electron Tomography (Postprint)

    Science.gov (United States)

    2013-02-01

    Reconstruction Technique ( SIRT ) are applied to the data. Model based iterative reconstruction (MBIR) provides a powerful framework for tomographic...the reconstruction when the typical algorithms such as Filtered Back Projection (FBP) and Simultaneous Iterative Reconstruction Technique ( SIRT ) are

  20. A novel image reconstruction methodology based on inverse Monte Carlo analysis for positron emission tomography

    Science.gov (United States)

    Kudrolli, Haris A.

    2001-04-01

    A three dimensional (3D) reconstruction procedure for Positron Emission Tomography (PET) based on inverse Monte Carlo analysis is presented. PET is a medical imaging modality which employs a positron emitting radio-tracer to give functional images of an organ's metabolic activity. This makes PET an invaluable tool in the detection of cancer and for in-vivo biochemical measurements. There are a number of analytical and iterative algorithms for image reconstruction of PET data. Analytical algorithms are computationally fast, but the assumptions intrinsic in the line integral model limit their accuracy. Iterative algorithms can apply accurate models for reconstruction and give improvements in image quality, but at an increased computational cost. These algorithms require the explicit calculation of the system response matrix, which may not be easy to calculate. This matrix gives the probability that a photon emitted from a certain source element will be detected in a particular detector line of response. The ``Three Dimensional Stochastic Sampling'' (SS3D) procedure implements iterative algorithms in a manner that does not require the explicit calculation of the system response matrix. It uses Monte Carlo techniques to simulate the process of photon emission from a source distribution and interaction with the detector. This technique has the advantage of being able to model complex detector systems and also take into account the physics of gamma ray interaction within the source and detector systems, which leads to an accurate image estimate. A series of simulation studies was conducted to validate the method using the Maximum Likelihood - Expectation Maximization (ML-EM) algorithm. The accuracy of the reconstructed images was improved by using an algorithm that required a priori knowledge of the source distribution. Means to reduce the computational time for reconstruction were explored by using parallel processors and algorithms that had faster convergence rates

  1. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  2. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  3. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...... have become the standard with which to assess emphysema extent but airway abnormalities have so far been more challenging to quantify. Automated methods for analysis are indispensable as the visible airway tree in a CT scan can include several hundreds of individual branches. However, automation...... of scan on airway dimensions in subjects with and without COPD. The results show measured airway dimensions to be affected by differences in the level of inspiration and this dependency is again influenced by COPD. Inspiration level should therefore be accounted for when measuring airways, and airway...

  4. Findings of computed tomography in intracranial tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Jo, H. G.; Bae, K. S.; Lee, H. K.; Kwon, K. H.; Kim, K. J. [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    In intracranial tuberculosis, the Computed Tomography (CT) is a new radiological technique which is helpful in diagnosis and determining the location, extents of the lesion. It can also make it possible to assess the presence and degree of the complications and to evaluate the effectiveness of treatment. 25 cases of clinically proven intracranial tuberculosis were studied by CT, in Soonchunhyang hospital from Jun. 1980 to Jun. 1983. The result were as follows; 1. 4 cases were normal in CT finding, despite of the clinically proven tuberculous meningitis. 2. Total or partial obliteration of cisterns were observed in 13 cases. 3. Intense abnormal contrast enhancement of the cisterns were observed in 8 cases. 4. 19 cases show moderate to marked ventricular dilatation. 5. 2 cases of cerebral infarction were observed. 6. One case of tuberculoma was observed.

  5. Computed tomography in metastatic renal cell carcinoma.

    Science.gov (United States)

    Griffin, Nyree; Grant, Lee Alexander; Bharwani, Nishat; Sohaib, S Aslam

    2009-08-01

    Recent developments in chemotherapy have resulted in several new drug treatments for metastatic renal cell carcinoma (RCC). These therapies have shown improved progression-free survival and are applicable to many more patients than the conventional cytokine-based treatments for metastatic RCC. Consequently imaging is playing a greater part in the management of such patients. Computed tomography (CT) remains the primary imaging modality with other imaging modalities playing a supplementary role. CT is used in the diagnosis and staging of metastatic RCC. It is used in the follow-up of patients after nephrectomy, in assessing the extent of metastatic disease, and in evaluating response to treatment. This review looks at the role of CT in patients with metastatic RCC and describes the appearances of metastatic RCC before and following systemic therapy.

  6. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  7. Computed tomography findings of malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka (Kure Kyosai Hospital, Hiroshima (Japan))

    1994-04-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author).

  8. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...... - CIA-CT”. In the comparison, 27 laboratories from 8 countries were involved, and CT scanned two items selected among common industrial parts: a polymer part and a metal part. Altogether, 27 sets of items were circulated in parallel to the participants. Different measurands are considered, encompassing...... influence from the surrounding wall thickness on the measurement of roundness was documented for the metal item. The comparison shows that CT scanning on small industrial parts, generally speaking, is connected with uncertainties in the range 8-53 μm, as compared to an uncertainty range of 1.5-5.5 μm using...

  9. Wavefront reconstruction using computer-generated holograms

    Science.gov (United States)

    Schulze, Christian; Flamm, Daniel; Schmidt, Oliver A.; Duparré, Michael

    2012-02-01

    We propose a new method to determine the wavefront of a laser beam, based on modal decomposition using computer-generated holograms (CGHs). Thereby the beam under test illuminates the CGH with a specific, inscribed transmission function that enables the measurement of modal amplitudes and phases by evaluating the first diffraction order of the hologram. Since we use an angular multiplexing technique, our method is innately capable of real-time measurements of amplitude and phase, yielding the complete information about the optical field. A measurement of the Stokes parameters, respectively of the polarization state, provides the possibility to calculate the Poynting vector. Two wavefront reconstruction possibilities are outlined: reconstruction from the phase for scalar beams and reconstruction from the Poynting vector for inhomogeneously polarized beams. To quantify single aberrations, the reconstructed wavefront is decomposed into Zernike polynomials. Our technique is applied to beams emerging from different kinds of multimode optical fibers, such as step-index, photonic crystal and multicore fibers, whereas in this work results are exemplarily shown for a step-index fiber and compared to a Shack-Hartmann measurement that serves as a reference.

  10. Computed tomography from photon statistics to modern cone-beam CT

    CERN Document Server

    Buzug, T M

    2008-01-01

    Tis book provides an overview of X-ray technology, the historic developmental milestones of modern CT systems, and gives a comprehensive insight into the main reconstruction methods used in computed tomography. Te basis of reconstr- tion is, undoubtedly, mathematics. However, the beauty of computed tomography cannot be understood without a detailed knowledge of X-ray generation, photon- matter interaction, X-ray detection, photon statistics, as well as fundamental signal processing concepts and dedicated measurement systems. Terefore, the reader will ?nd a number of references to these basic d

  11. Fibrous twists and turns: early ceramic technology revealed through computed tomography

    Science.gov (United States)

    Sanger, Matthew; Thostenson, James; Hill, Morgan; Cain, Hannah

    2013-06-01

    While the emergence of pottery manufacturing is a wide-spread historical occurrence, and one that has garnered the attention of archaeologists for decades, we know very little about how these ancient vessels were created. Through the application of radiographic scanning and computed tomography this paper provides insights into the manufacturing techniques used by the earliest potters in North America. While x-rays have been used to investigate ceramic manufacturing techniques for decades, this paper provides a reassessment of radiography in light of advances in both computed tomography and reconstructive software.

  12. Fast X-ray luminescence computed tomography imaging.

    Science.gov (United States)

    Liu, Xin; Liao, Qimei; Wang, Hongkai

    2014-06-01

    X-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging with X-ray. However, challenges remain in dynamic XLCT imaging, where short scan time, good spatial resolution, and whole-body field of view should be considered simultaneously. In this paper, by the use of a single-view XLCT reconstruction method based on a compressive sensing (CS) technique, incorporating a cone beam XLCT imaging system, we implement fast 3-D XLCT imaging. To evaluate the performance of the method, two types of phantom experiments were performed based on a cone beam XLCT imaging system. In Case 1, one tube filled with the X-ray-excitable nanophosphor (Gd 2O 3 :Eu (3+)) was immerged in different positions in the phantom to evaluate the effect of the source position on single-view XLCT reconstruction accuracy. In Case 2, two tubes filled with Gd 2O 3 :Eu (3+) were immerged in different heights in the phantom to evaluate the whole-body imaging performance of single-view XLCT reconstruction. The experimental results indicated that the tubes used in previous phantom experiments can be resolved from single-view XCLT reconstruction images. The location error is less than 1.2 mm. In addition, since only one view data are needed to implement 3-D XLCT imaging, the acquisition time can be greatly reduced (∼1 frame/s) compared with previous XLCT systems. Hence, the technique is suited for imaging the fast distribution of the X-ray-excitable nanophosphors within a biological object.

  13. Intravenous coronary angiography using electron beam computed tomography

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A H; van Geuns, R J; van Ooijen, P M; Oudkerk, M; de Feyter, P J

    1999-01-01

    Intravenous coronary angiography with electron beam computed tomography (EBCT) allows for the noninvasive visualisation of coronary arteries. With dedicated computer hardware and software, three-dimensional renderings of the coronary arteries, veins, and other cardiac structures can be constructed f

  14. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  15. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J.N.; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  16. Computed tomography in traumatic defects of the diaphragm.

    Science.gov (United States)

    Demos, T C; Solomon, C; Posniak, H V; Flisak, M J

    1989-03-01

    Two patients with traumatic diaphragmatic defects visible on computed tomography are presented. The diagnosis was delayed for several years in both patients. The diagnosis of these acquired diaphragmatic defects is often difficult. Computed tomography can lead to earlier diagnosis by demonstrating the defect in some patients when radiographic studies are not diagnostic.

  17. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  18. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on t

  19. Sound field reconstruction using acousto-optic tomography

    DEFF Research Database (Denmark)

    Torras Rosell, Antoni; Barrera Figueroa, Salvador; Jacobsen, Finn

    2012-01-01

    When sound propagates through a medium, it results in pressure fluctuations that change the instantaneous density of the medium. Under such circumstances, the refractive index that characterizes the propagation of light is not constant, but influenced by the acoustic field. This kind of interaction...... the acousto-optic effect in air, and demonstrates that it can be measured with a laser Doppler vibrometer in the audible frequency range. The tomographic reconstruction is tested by means of computer simulations and measurements. The main features observed in the simulations are also recognized...

  20. Molecular Imaging : Computer Reconstruction and Practice - Proceedings of the NATO Advanced Study Institute on Molecular Imaging from Physical Principles to Computer Reconstruction and Practice

    CERN Document Server

    Lemoigne, Yves

    2008-01-01

    This volume collects the lectures presented at the ninth ESI School held at Archamps (FR) in November 2006 and is dedicated to nuclear physics applications in molecular imaging. The lectures focus on the multiple facets of image reconstruction processing and management and illustrate the role of digital imaging in clinical practice. Medical computing and image reconstruction are introduced by analysing the underlying physics principles and their implementation, relevant quality aspects, clinical performance and recent advancements in the field. Several stages of the imaging process are specifically addressed, e.g. optimisation of data acquisition and storage, distributed computing, physiology and detector modelling, computer algorithms for image reconstruction and measurement in tomography applications, for both clinical and biomedical research applications. All topics are presented with didactical language and style, making this book an appropriate reference for students and professionals seeking a comprehen...

  1. Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution

    Directory of Open Access Journals (Sweden)

    Frank P. DiFilippo

    2012-05-01

    Full Text Available Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT, an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling were investigated. National Electrical Manufacturers Association (NEMA NU 4 phantom and mouse data were acquired with a clinical PET/CT scanner, as both conventional static and stepped scans. Static scans were reconstructed with and without point spread function (PSF modeling. Stepped images were postprocessed with iterative deconvolution to produce super-resolution images. Image quality was markedly improved using the super-resolution technique, avoiding certain artifacts produced by PSF modeling. The 2 mm rod of the NU 4 phantom was visualized with high contrast, and the major structures of the mouse were well resolved. Although not a perfect substitute for a state-of-the-art small-animal PET/CT scanner, a clinical PET/CT scanner with super-resolution produces acceptable small-animal image quality for many preclinical research studies.

  2. On the computational implementation of forward and back-projection operations for cone-beam computed tomography.

    Science.gov (United States)

    Karimi, Davood; Ward, Rabab

    2016-08-01

    Forward- and back-projection operations are the main computational burden in iterative image reconstruction in computed tomography. In addition, their implementation has to be accurate to ensure stable convergence to a high-quality image. This paper reviews and compares some of the variations in the implementation of these operations in cone-beam computed tomography. We compare four algorithms for computing the system matrix, including a distance-driven algorithm, an algorithm based on cubic basis functions, another based on spherically symmetric basis functions, and a voxel-driven algorithm. The focus of our study is on understanding how the choice of the implementation of the system matrix will influence the performance of iterative image reconstruction algorithms, including such factors as the noise strength and spatial resolution in the reconstructed image. Our experiments with simulated and real cone-beam data reveal the significance of the speed-accuracy trade-off in the implementation of the system matrix. Our results suggest that fast convergence of iterative image reconstruction methods requires accurate implementation of forward- and back-projection operations, involving a direct estimation of the convolution of the footprint of the voxel basis function with the surface of the detectors. The required accuracy decreases by increasing the resolution of the projection measurements beyond the resolution of the reconstructed image. Moreover, reconstruction of low-contrast objects needs more accurate implementation of these operations. Our results also show that, compared with regularized reconstruction methods, the behavior of iterative reconstruction algorithms that do not use a proper regularization is influenced more significantly by the implementation of the forward- and back-projection operations.

  3. Dose reduction in computed tomography of the chest. Image quality of iterative reconstructions at a 50% radiation dose compared to filtered back projection at a 100% radiation dose; Dosisreduktion in der Thorax-CT. Vergleich der Bildqualitaet bei 50% Dosis und iterativer Bildrekonstruktion mit 100% Dosis und gefilterter Rueckprojektion

    Energy Technology Data Exchange (ETDEWEB)

    May, M.S.; Eller, A.; Stahl, C. [University Hospital Erlangen (Germany). Dept. of Radiology; and others

    2014-06-15

    Purpose: The aim of this study was to evaluate the potential of iterative reconstruction (IR) in chest computed tomography (CT) to reduce radiation exposure. The qualitative and quantitative image quality of standard reconstructions with filtered back projection (FBP) and half dose (HD) chest CT data reconstructed with FBP and IR was assessed. Materials and Methods: 52 consecutive patients underwent contrast-enhanced chest CT on a dual-source CT system at 120 kV and automatic exposure control. The tube current was equally split on both tube detector systems. For the HD datasets, only data from one tube detector system was utilized. Thus, FD and HD data was available for each patient with a single scan. Three datasets were reconstructed from the raw data: standard full dose (FD) images applying FBP which served as a reference, HD images applying FBP and IR. Objective image quality analysis was performed by measuring the image noise in tissue and air. The subjective image quality was evaluated by 2 radiologists according to European guidelines. Additional assessment of artifacts, lesion conspicuity and edge sharpness was performed. Results: Image noise did not differ significantly between HD-IR and FD-FBP (p = 0.254) but increased substantially in HD-FBP (p < 0.001). No statistically significant differences were found for the reproduction of anatomical and pathological structures between HD-IR and FD-FBP, subsegmental bronchi and bronchioli. The image quality of HD-FBP was rated inferior because of increased noise. Conclusion: A 50% dose reduction in contrast-enhanced chest CT is feasible without a loss of diagnostic confidence if IR is used for image data reconstruction. Iterative reconstruction is another powerful tool to reduce radiation exposure and can be combined with other dose-saving techniques. (orig.)

  4. Proton computed tomography using a 1D silicon diode array.

    Science.gov (United States)

    Wang, Peng; Cammin, Jochen; Bisello, Francesca; Solberg, Timothy D; McDonough, James E; Zhu, Timothy C; Menichelli, David; Teo, Boon-Keng Kevin

    2016-10-01

    Proton radiography (PR) and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. A one-dimensional silicon diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. Two-dimensional proton radiographs were obtained by translation and rotation of a phantom relative to CAX while the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data. The resolution and maximum error in WET measurement are 2.0 and 1.5 mm, respectively. Structures down to 2.0 mm in size could be resolved completely. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition and high spatial and energy resolution for PR and PCT.

  5. Computed tomography: acquisition process, technology and current state

    Directory of Open Access Journals (Sweden)

    Óscar Javier Espitia Mendoza

    2016-02-01

    Full Text Available Computed tomography is a noninvasive scan technique widely applied in areas such as medicine, industry, and geology. This technique allows the three-dimensional reconstruction of the internal structure of an object which is lighted with an X-rays source. The reconstruction is formed with two-dimensional cross-sectional images of the object. Each cross-sectional is obtained from measurements of physical phenomena, such as attenuation, dispersion, and diffraction of X-rays, as result of their interaction with the object. In general, measurements acquisition is performed with methods based on any of these phenomena and according to various architectures classified in generations. Furthermore, in response to the need to simulate acquisition systems for CT, software dedicated to this task has been developed. The objective of this research is to determine the current state of CT techniques, for this, a review of methods, different architectures used for the acquisition and some of its applications is presented. Additionally, results of simulations are presented. The main contributions of this work are the detailed description of acquisition methods and the presentation of the possible trends of the technique.

  6. Impact of nonstationary optical illumination on image reconstruction in optoacoustic tomography.

    Science.gov (United States)

    Lou, Yang; Wang, Kun; Oraevsky, Alexander A; Anastasio, Mark A

    2016-12-01

    Optoacoustic tomography (OAT), also known as photoacoustic tomography, is a rapidly emerging hybrid imaging technique that possesses great potential for a wide range of biomedical imaging applications. In OAT, a laser is employed to illuminate the tissue of interest and acoustic signals are produced via the photoacoustic effect. From these data, an estimate of the distribution of the absorbed optical energy density within the tissue is reconstructed, referred to as the object function. This quantity is defined, in part, by the distribution of light fluence within the tissue that is established by the laser source. When performing three-dimensional imaging of large objects, such as a female human breast, it can be difficult to achieve a relatively uniform coverage of light fluence within the volume of interest when the position of the laser source is fixed. To circumvent this, researchers have proposed illumination schemes in which the relative position of the laser source and ultrasound probe is fixed, and both are rotated together to acquire a tomographic dataset. A problem with this rotating-illumination scheme is that the tomographic data are inconsistent; namely, the acoustic data recorded at each tomographic view angle (i.e., probe position) are produced by a distinct object function. In this work, the impact of this data inconsistency on image reconstruction accuracy is investigated systematically. This is accomplished by use of computer-simulation studies and application of mathematical results from the theory of microlocal analysis. These studies specify the set of image discontinuities that can be stably reconstructed with a nonstationary optical illumination setup. The study also includes a comparison of the ability of iterative and analytic image reconstruction methods to mitigate artifacts attributable to the data inconsistency.

  7. Two and three-dimensional computed tomography for the classification and management of distal humeral fractures - Evaluation of reliability and diagnostic accuracy

    NARCIS (Netherlands)

    J. Doornberg; A. Lindenhovius; P. Kloen; C.N. van Dijk; D. Zurakowski; D. Ring

    2006-01-01

    Background: Complex fractures of the distal part of the humerus can be difficult to characterize on plain radiographs and two-dimensional computed tomography scans. We tested the hypothesis that three-dimensional reconstructions of computed tomography scans improve the reliability and accuracy of fr

  8. X-Ray Computed Tomography for Advanced Materials and Processes.

    Science.gov (United States)

    1992-06-30

    percent. In this example, we have assumed $I M, $5(X)K and $200K CT systems operating at 10 percent of the capital investment per year for maintenance...Computed Tomo &:aphy of Composites," WRDC-TR-90-4014, July 1990. 5. P. Burstein and R. H. Bossi, "A Guide to Computed Tomography System Specifications," WRDC...Lannutti, "Applications of High- Resolution Computed Tomography," Proceedings of the 1991 Industrial Computed Tomography II Topical Conference, May 20-24

  9. Early-photon guided reconstruction method for time-domain fluorescence lifetime tomography

    Institute of Scientific and Technical Information of China (English)

    Lin Zhang; Chuangjian Cai; Yanlu Lv; Jianwen Luo

    2016-01-01

    A reconstruction method guided by early-photon fluorescence yield tomography is proposed for time-domain fluorescence lifetime tomography (FLT) in this study.The method employs the early-arriving photons to reconstruct a fluorescence yield map,which is utilized as a priori information to reconstruct the FLT via all the photons along the temporal-point spread functions.Phantom experiments demonstrate that,compared with the method using all the photons for reconstruction of fluorescence yield and lifetime maps,the proposed method can achieve higher spatial resolution and reduced crosstalk between different targets without sacrificing the quantification accuracy of lifetime and contrast between heterogeneous targets.

  10. Low dose four-dimensional computerized tomography with volume rendering reconstruction for primary hyperparathyroidism: How I do it?

    Institute of Scientific and Technical Information of China (English)

    Timothy; A; Platz; Moshim; Kukar; Rania; Elmarzouky; William; Cance; Ahmed; Abdelhalim

    2014-01-01

    Abstract Modification of 4-dimensional computed tomography(4D-CT)technique with volume rendering reconstruc-tions and significant dose reduction is a safe and ac-curate method of pre-operative localization for primary hyperparathyroidism.Modified low dose 4D-CT with volume rendering reconstructions provides precise preoperative localization and is associated with a sig-nificant reduction in radiation exposure compared to classic preoperative localizing techniques.It should be considered the preoperative localization study of choice for primary hyperparathyroidism.

  11. Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease.

    Science.gov (United States)

    Tada, Akihiro; Sato, Shuhei; Kanie, Yuichiro; Tanaka, Takashi; Inai, Ryota; Akagi, Noriaki; Morimitsu, Yusuke; Kanazawa, Susumu

    2016-03-01

    The objective of this study was to assess factors affecting image quality of 320-row computed tomography angiography (CTA) of coronary arteries in children with congenital heart disease (CHD). We retrospectively reviewed 28 children up to 3 years of age with CHD who underwent prospective electrocardiography (ECG)-gated 320-row CTA with iterative reconstruction. We assessed image quality of proximal coronary artery segments using a five-point scale. Age, body weight, average heart rate, and heart rate variability were recorded and compared between two groups: patients with good diagnostic image quality in all four coronary artery segments and patients with at least one coronary artery segment with nondiagnostic image quality. Altogether, 96 of 112 segments (85.7 %) had diagnostic-quality images. Patients with nondiagnostic segments were significantly younger (10.0 ± 11.6 months) and had lower body weight (5.9 ± 2.9 kg) (each p heart rate and heart rate variability between the two imaging groups were not significant. Receiver operating characteristic analyses for predicting patients with nondiagnostic image quality revealed an optimal body weight cutoff of ≤5.6 kg and an optimal age cutoff of ≤12.5 months. Prospective ECG-gated 320-row CTA with iterative reconstruction provided feasible image quality of coronary arteries in children with CHD. Younger age and lower body weight were factors that led to poorer image quality of coronary arteries.

  12. Micro computed tomography for vascular exploration

    Directory of Open Access Journals (Sweden)

    Zhuang Zhen W

    2010-03-01

    Full Text Available Abstract Vascular exploration of small animals requires imaging hardware with a very high spatial resolution, capable of differentiating large as well as small vessels, in both in vivo and ex vivo studies. Micro Computed Tomography (micro-CT has emerged in recent years as the preferred modality for this purpose, providing high resolution 3D volumetric data suitable for analysis, quantification, validation, and visualization of results. The usefulness of micro-CT, however, can be adversely affected by a range of factors including physical animal preparation, numerical quantification, visualization of results, and quantification software with limited possibilities. Exacerbating these inherent difficulties is the lack of a unified standard for micro-CT imaging. Most micro-CT today is aimed at particular applications and the software tools needed for quantification, developed mainly by imaging hardware manufacturers, lack the level of detail needed to address more specific aims. This review highlights the capabilities of micro-CT for vascular exploration, describes the current state of imaging protocols, and offers guidelines and suggestions aimed at making micro-CT more accurate, replicable, and robust.

  13. Radiation doses from computed tomography in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, J.E.M.; Tingey, D.R.C

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors) 28 refs., 11 tabs., 10 figs.

  14. Dedicated breast computed tomography: Basic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Sarno, Antonio; Mettivier, Giovanni, E-mail: mettivier@na.infn.it; Russo, Paolo [Dipartimento di Fisica, Università di Napoli Federico II, Via Cintia, Napoli I-80126, Italy and INFN Sezione di Napoli, Napoli I-80126 (Italy)

    2015-06-15

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

  15. Computed tomography characterisation of additive manufacturing materials.

    Science.gov (United States)

    Bibb, Richard; Thompson, Darren; Winder, John

    2011-06-01

    Additive manufacturing, covering processes frequently referred to as rapid prototyping and rapid manufacturing, provides new opportunities in the manufacture of highly complex and custom-fitting medical devices and products. Whilst many medical applications of AM have been explored and physical properties of the resulting parts have been studied, the characterisation of AM materials in computed tomography has not been explored. The aim of this study was to determine the CT number of commonly used AM materials. There are many potential applications of the information resulting from this study in the design and manufacture of wearable medical devices, implants, prostheses and medical imaging test phantoms. A selection of 19 AM material samples were CT scanned and the resultant images analysed to ascertain the materials' CT number and appearance in the images. It was found that some AM materials have CT numbers very similar to human tissues, FDM, SLA and SLS produce samples that appear uniform on CT images and that 3D printed materials show a variation in internal structure.

  16. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  17. Virtual computed tomography cystoscopy in bladder pathologies

    Directory of Open Access Journals (Sweden)

    Halil Arslan

    2006-04-01

    Full Text Available OBJECTIVE: Assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT in patients with different urinary bladder pathologies compared to the conventional cystoscopy. MATERIALS AND METHODS: Eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. RESULTS: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88% of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. CONCLUSION: Virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion.

  18. Virtual computed tomography cystoscopy in bladder pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban [Yuzuncu Yil University School of Medicine, Van (Turkey). Dept. of Radiology and Urology]. E-mail: drhalilarslan@hotmail.com

    2006-03-15

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  19. Application of computed tomography to spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Sha, N.; Kurihara, A.; Kataoka, O. (Kobe Univ. (Japan). School of Medicine)

    1980-08-01

    The axial tomographic examination of the spine and its soft tissues is now readily available for orthopaedic surgery. If the appropriate conditions are maintained, computed tomography (CT) can provide useful information concerning the diagnosis and the treatment of spinal diseases. There are, however, some pitfalls in interpreting CT scans: 1) the existence of the lesion may be masked, and 2) its extent and configuration may be over- or under-evaluated depending on such technical factors as the slicing level, the slicing angle, the window width, and the window level. Experimental studies were carried out on a plaster of Paris model of the spine and a cadaver spine to determine the appropriate technical factors by which the CT (EMI whole body CT scanner 5005) can be applied accurately to a diseased spine. The factors obtained were then applied in examining ninety-nine patients with various spinal disorders. Window levels ranging between 100 and 150 were found to be most appropriate. The slicing angle should be 90/sup 0/, or perpendicular to the long axis of the object under study. However, deviations of +10 or -10 degrees are acceptable. The CT view of the spine may be divided into two patterns at the cervical and thoracic levels and into three patterns at the lumbar level. In addition, the usefulness and the diagnostic value of CT for various spinal problems are discussed based on our clinical material.

  20. Computed tomography in acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, Karl-Olof [HUG-Geneva University Hospital, Geneva University Medical School, Department of Neuroradiology, Department of Imaging and Medical Informatics, Geneva (Switzerland); Baird, Alison E. [SUNY Downstate Medical Center, Cerebrovascular Disease and Stroke, 450 Clarkson Avenue, Box 1213, Brooklyn, NY (United States)

    2010-03-15

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  1. Computed tomography of the orbital lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Eon; Suh, Soo Jhi; Kim, Ho Kyun; Kim, Soon Yong [Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    1980-06-15

    The use of computed tomography in investigation of orbital lesions was of value for the localization of the lesions as well as making the specific diagnosis. We advocated the combined use of transverse axial section and contrast enhancement in CT as a routine procedure often including coronal section in the diagnosis of orbital lesions because of its usefulness and more precise three dimensional imaging. The authors examined 68 patients with various ophthalmic problems by EMI-CT scanner 5005 from October 1977 to November 1979. Fifty one orbital lesions out of 68 CT scans were analyzed by CT, angiography and operative findings and results were as follows; 1. Among 43 males and 25 females, their age range was from 4 months to 66 years with the most frequent age group of first decade (17 cases; 25%) 2. The distribution of the lesions was mucocele, pseudotumor, optic nerve atrophy, metastasis, lacrimal gland tumor, persistent hypertrophic primary vitreous, granulosa cell myoblastoma, hemangioma in order with 13 malignancies (25%). 3. It was difficult to differentiate pathological diagnosis of the lesions, but the character of the lesions was determined by its characteristic location, and its relationship to eyeball, optic nerve, extraocular muscles and bony orbit. 4. It was thought that more accurate diagnosis of orbital lesions could be made by development of CT scanner having fine matrix, short time exposure and thin slice in the future.

  2. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir

    2016-09-06

    Wavefield tomography can handle complex subsurface geology better than ray-based techniques and, ultimately, provide a higher resolution. Here, we implement forward and adjoint wavefield extrapolation for VTI (transversely isotropic with a vertical symmetry axis) media using a pseudospectral operator that employes a separable approximation of the P-wave dispersion relation. This operator is employed to derive the gradients of the differential semblance optimization (DSO) and modified stack-power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space-time finite-difference (FD) scheme for a system of coupled wave equations. Whereas the kernels computed with the two wave-equation operators are similar, the pseudospectral method is not hampered by the imprint of the shear-wave artifact. Numerical examples also show that the modified stack-power objective function produces cleaner gradients than the more conventional DSO operator.

  3. Perfusion computed tomography in renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Chandan; J; Das; Usha; Thingujam; Ananya; Panda; Sanjay; Sharma; Arun; Kumar; Gupta

    2015-01-01

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma(RCC). While contrast enhanced computed tomography(CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT(p CT), goes down to the molecular level and provides new perspectives in imaging of RCC. p CT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using p CT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of p CT in staging and response assessment in patients with RCCs.

  4. Computer tomography-aided ventriculography and cisternography

    Energy Technology Data Exchange (ETDEWEB)

    Cernoch, Z.; Sercl, M.; Heger, L.; Parizek, J. (Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta)

    1983-01-28

    Computer tomography was used in 42 patients for the exploration of ventricular and subarachnoidal spaces following intraventricular, lumbar or suboccipital injections of 3 to 5 ml Amipaque using the kind of manoeuvre to permit optimum filling of the region concerned. This type of CT ventriculo- or cisternography is a significant supplement to plain CT examination particularly because it supplies data on the causes of CSF passage blocks. Thus, in two female patients it proved possible to localize cysts in the 3rd ventricle, the density of which was no different from that of CSF. As regards benign stenoses of the aqueduct, it is likely to yield less information than conventional specific ventriculography. On the other hand, the technique gives perfect visualization of all possible communications between pathological intracranial cavities and the ventricular system. CT cisternography proved useful for the identification of small-size isodense growths in the region of the sella turcica, and brought convincing evidence of the causes of profuse liquorrhea by demonstrating the presence of nasal meningocele. It was also found helpful in the analysis of the craniocervical region, otherwise difficult to survey.

  5. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  6. Stable reconstruction of piecewise continuous plane stratified biological tissues via electrical impedance tomography.

    Science.gov (United States)

    Dolgin, Madlena; Einziger, Pinchas D

    2010-05-01

    Image reconstruction in electrical impedance tomography is, generally, an ill-posed nonlinear inverse problem. Regularization methods are widely used to ensure a stable solution. Herein, we present a case study, which uses a novel electrical impedance tomography method for reconstruction of layered biological tissues with piecewise continuous plane-stratified profiles. The algorithm implements the recently proposed reconstruction scheme for piecewise constant conductivity profiles, utilizing Legendre expansion in conjunction with improved Prony method. It is shown that the proposed algorithm is capable of successfully reconstructing piecewise continuous conductivity profiles with moderate slop. This reconstruction procedure, which calculates both the locations and the conductivities, repetitively provides inhomogeneous depth discretization, i.e., the depths grid is not equispaced. Incorporation of this specific inhomogeneous grid in the widely used mean least square reconstruction procedure results in a stable and accurate reconstruction, whereas, the commonly selected equispaced depth grid leads to unstable reconstruction. This observation establishes the main result of our investigation, highlighting the impact of physical phenomenon (the image series expansion) on electrical impedance tomography, leading to a physically motivated stabilization of the inverse problem, i.e., an inhomogeneous depth discretization renders an inherent regularization of the mean least square algorithm. The effectiveness and the significance of inhomogeneous discretization in electrical impedance tomography reconstruction procedure is further demonstrated and verified via numerical simulations.

  7. Multiscale and multimodality computed tomography for cortical bone analysis

    Science.gov (United States)

    Ostertag, A.; Peyrin, F.; Gouttenoire, P. J.; Laredo, J. D.; DeVernejoul, M. C.; Cohen Solal, M.; Chappard, C.

    2016-12-01

    In clinical studies, high resolution peripheral quantitative computed tomography (HR-pQCT) is used to separately evaluate cortical bone and trabecular bone with an isotropic voxel of 82 µm3, and typical cortical parameters are cortical density (D.comp), thickness (Ct.Th), and porosity (Ct.Po). In vitro, micro-computed tomography (micro-CT) is used to explore the internal cortical bone micro-structure with isotropic voxels and high resolution synchrotron radiation (SR); micro-CT is considered the ‘gold standard’. In 16 tibias and 8 femurs, HR-pQCT measurements were compared to conventional micro-CT measurements. To test modality effects, conventional micro-CT measurements were compared to SR micro-CT measurements at 7.5 µm3 SR micro-CT measurements were also tested at different voxel sizes for the femurs, specifically, 7.5 µm3 versus 2.8 µm3. D.comp (r  =  -0.88, p  images provided consistent results compared to those obtained using conventional micro-CT at the distal tibia. D.comp was highly correlated to Po.V/TV because it considers both the micro-porosity (Haversian systems) and macro-porosity (resorption lacunae) of cortical bone. The complexity of canal organization, (including shape, connectivity, and surface) are not fully considered in conventional micro-CT in relation to beam hardening and cone beam reconstruction artifacts. With the exception of Po.V/TV measurements, morphological and topological measurements depend on the characteristics of the x-ray beam, and to a lesser extent, on image resolution.

  8. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  9. Diffuse abnormalities of the trachea: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@gmail.com; Pozes, Aline Serfaty [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Escola de Medicina. Dept. de Radiologia; Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Radiologia; Irion, Klaus Loureiro [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Barillo, Jorge Luiz; Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil). Dept. de Cirurgia Clinica; Souza, Carolina Althoff [University of Ottawa, Ottawa, ON (Canada)

    2008-01-15

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  10. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings*

    Science.gov (United States)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tânia Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanês, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mário Flores

    2015-01-01

    Objective To evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and Methods Retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results Abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion Computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. PMID:25987748

  11. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  12. Image recovery techniques for x-ray computed tomography in limited data environments

    Energy Technology Data Exchange (ETDEWEB)

    Aufderheide, M B; Goodman, D M; Jackson, J A; Johansson, E M

    1999-03-01

    There is an increasing requirement throughout LLNL for nondestructive evaluation using X-ray computed tomography (CT). In many cases, restrictions on data acquisition time, imaging geometry, and budgets make it unfeasible to acquire projection data over enough views to achieve desired spatial resolution using conventional CT methods. In particular, conventional CT methods are non-iterative algorithms that have the advantage of low computational effort, but they are not sufficiently adaptable to incorporate prior information or non-Gaussian statistics. Most currently existing iterative tomography algorithms are based on methods that are time consuming because they converge very flowingly, if at all. The goal of the work was to develop a set of limited data CT reconstruction tools and then demonstrate their usefulness by applying them to a variety of problems of interest to LLNL. In this project they continued their development of reconstruction tools and they have demonstrated their effectiveness on several important problems.

  13. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  14. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  15. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    2005-01-01

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic mo

  16. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  17. Positron emission tomography/computed tomography for optimized colon cancer staging and follow up

    DEFF Research Database (Denmark)

    Engelmann, Bodil Elisabeth; Loft, Annika; Kjær, Andreas;

    2014-01-01

    OBJECTIVES: Optimal management of colon cancer (CC) requires detailed assessment of extent of disease. This study prospectively investigates the diagnostic accuracy of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) for staging and detection of recurrence...