WorldWideScience

Sample records for computed tomography initial

  1. Initial water quantification results using neutron computed tomography

    Science.gov (United States)

    Heller, A. K.; Shi, L.; Brenizer, J. S.; Mench, M. M.

    2009-06-01

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at the Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  2. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  3. The initial appearance of lung adenocarcinoma on computed tomography

    International Nuclear Information System (INIS)

    Saito, Haruhiro; Yamada, Kozo; Suzuki, Rie; Oshita, Fumihiro; Nakayama, Haruhiko; Mitsuda, Aki; Kameda, Youichi; Noda, Kazumasa

    2002-01-01

    The purpose of this study was to determine the initial appearance of lung adenocarcinoma on computed tomography and the appropriate follow-up duration. Retrospective review of 17 cases in which computed tomography (CT) of the chest was performed about 2 years prior to the diagnosis of lung cancer. The diagnosis was confirmed by surgical resection in all cases. The lung cancers were divided into four types based on their appearance on the initial CT: ground-glass opacity (GGO)-like images in which the lesion appeared as a faint opacity, BLA (bubble-like appearance) image, in which the lesion resembled a focal collection of air, a small solitary nodule, and a scar-like image. Vascular involvement, air-bronchogram, and pleural indentation were all more prominent during a serial scan obtained just prior to surgery than on the initial scan. An increase in vascular involvement occurred prior to the other changes. High attenuation areas appeared in the GGO-like lesions prior to an increase in the size of the lesion. The growth pattern was classified as slow growing, rapidly growing, and initially slow growing with accelerated growth. The doubling time was similar in lesions with the same appearance. This information can be used to guide follow-up of images suspected of lung cancer. The appropriate follow-up duration is estimated from 6 to 12 months for GGO and BLA-like images, and from 2 to 3 months for small solitary nodules. The biological behavior of lung cancer is reflected in their initial appearance on CT. (author)

  4. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  5. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  6. Non-Traumatic Ureteral Rupture Despite Initial Normal Appearance Assessed by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chien-Kan Chen

    2009-03-01

    Full Text Available Rupture of the urinary collecting system with urinary extravasations is a condition that leads to presentation of abdominal pain. The most common cause is usually associated with urolithiasis related obstructive nephropathy. A man aged 69 years suddenly suffered from intense pain over the left hemi-abdomen and flank area. The initial imaging studies of plain film, abdominal sonography, and enhanced and non-enhanced computed tomography scan were unremarkable. Post-contrast plain film showed left-sided urinary extravasations. Surgical intervention ensued and the patient recovered without later urinary complaints. We found that a delayed plain film after intravenous contrast media for computed tomography is helpful to evaluate the urinary tract in its entirety. It is also practical and useful for the detection of leakage from the urinary tract.

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  8. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  9. [Positron emission tomography combined with computed tomography in the initial evaluation and response assessment in primary central nervous system lymphoma].

    Science.gov (United States)

    Mercadal, Santiago; Cortés-Romera, Montserrat; Vélez, Patricia; Climent, Fina; Gámez, Cristina; González-Barca, Eva

    2015-06-08

    To evaluate the role of positron emission tomography combined with computed tomography (PET-CT) in the initial evaluation and response assessment in primary central nervous system lymphoma (PCNSL). Fourteen patients (8 males) with a median age 59.5 years diagnosed of PCNSL. A brain PET-CT and magnetic resonance imaging (MRI) were performed in the initial evaluation. In 7 patients a PET-CT after treatment was performed. PET-CT showed at diagnosis 31 hypermetabolic focuses and MRI showed 47 lesions, with a good grade of concordance between both (k = 0.61; P = .005). In the response assessment, correlation between both techniques was good, and PET-CT was helpful in the appreciation of residual MRI lesions. Overall survival at 2 years of negative vs. positive PET-CT at the end of treatment was 100 vs. 37.5%, respectively (P = .045). PET-CT can be useful in the initial evaluation of PCNSL, and especially in the assessment of response. Despite the fact that PET-CT detects less small lesions than MRI, a good correlation between MRI and PET-CT was observed. It is effective in the evaluation of residual lesions. Prospective studies are needed to confirm their possible prognostic value. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  10. Initial screening test for blunt cerebrovascular injury: Validity assessment of whole-body computed tomography.

    Science.gov (United States)

    Laser, Adriana; Kufera, Joseph A; Bruns, Brandon R; Sliker, Clint W; Tesoriero, Ronald B; Scalea, Thomas M; Stein, Deborah M

    2015-09-01

    Our whole-body computed tomography protocol (WBCT), used to image patients with polytrauma, consists of a noncontrast head computed tomography (CT) followed by a multidetector computed tomography (40- or 64- slice) that includes an intravenous, contrast-enhanced scan from the face through the pelvis. WBCT is used to screen for blunt cerebrovascular injury (BCVI) during initial CT imaging of the patient with polytrauma and allows for early initiation of therapy with the goal of avoiding stroke. WBCT has not been directly compared with CT angiography (CTA) of the neck as a screening tool for BCVI. We hypothesize that WBCT is a valid modality to diagnose BCVI compared with neck CTA, thus screening patients with polytrauma for BCVI and limiting the need for subsequent CTA. A retrospective review of the trauma registry was conducted for all patients diagnosed with BCVI from June 2009 to June 2013 at our institution. All injuries, identified and graded on initial WBCT, were compared with neck CTA imaging performed within the first 72 hours. Sensitivity was calculated for WBCT by the use of CTA as the reference standard. Proportions of agreement also were calculated between the grades of injury for both imaging modalities. A total of 319 injured vessels were identified in 227 patients. On initial WBCT 80 (25%) of the injuries were grade I, 75 (24%) grade II, 45 (14%) grade III, 41 (13%) grade IV, and 58 (18%) were classified as indeterminate: 27 vertebral and 31 carotid lesions. Twenty (6%) of the 319 injuries were not detected on WBCT but identified on subsequent CTA (9 grade I, 7 grade II, 4 grade III); 6 vertebral and 14 carotid. For each vessel type and for all vessels combined, WBCT demonstrated sensitivity rates of over 90% to detect BCVI among the population of patients with at least one vessel injured. There was concordant grading of injuries between WBCT and initial diagnostic CTA in 154 (48% of all injuries). Lower grade injures were more discordant than higher

  11. Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaou, Konstantin; Becker, Christoph R.; Reiser, Maximilian F. [Ludwig-Maximilians-University, Department of Clinical Radiology, Munich (Germany); Flohr, Thomas; Stierstorfer, Karl [CT Division, Siemens Medical Solutions, Forchheim (Germany)

    2005-02-01

    The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024 x 768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25 x 0.25 x 0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed. (orig.)

  12. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Universidade Federal do Espirito Santo (HUCAM/UFES), Vitoria, ES (Brazil). Hospital Universitario Cassiano Antonio de Morais. Radiologia e Diagnostico por Imagem

    2017-03-15

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  13. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens; Universidade Federal do Espirito Santo

    2017-01-01

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  14. Accuracy of 16-detector Multislice Spiral Computed Tomography in the initial evaluation of dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Cornily, Jean-Christophe; Gilard, Martine; Le Gal, Gregoire; Pennec, Pierre-Yves; Vinsonneau, Ulric; Blanc, Jean-Jacques; Mansourati, Jacques; Boschat, Jacques

    2007-01-01

    Background: Multislice Computed Tomography (MSCT) recently proved its accuracy in the detection of coronary artery disease (CAD). It can also give information about left ventricular function and venous network anatomy. We here sought to validate a MSCT-based strategy in the initial evaluation of patients with dilated cardiomyopathy (DCM). Methods: 36 patients with DCM underwent cardiac MSCT before conventional coronary angiography with ventriculography. We analysed arterial calcium score (Agatston score equivalent: ASE), coronary stenosis, left ventricular parameters and venous network. Results: The sensitivity of a MSCT-based strategy in detecting significant CAD was 100% and the specificity 80%. The positive and negative predictive values were respectively 67% and 100%. For ASE 1.000, conventional coronary angiography is mandatory due to MSCT's poor interest in such cases; when ASE <1.000, a contrast-enhanced MSCT may, when normal, replace coronary angiography

  15. Costs and role of ultrasound follow-up of polytrauma patients after initial computed tomography

    International Nuclear Information System (INIS)

    Maurer, M.H.; Winkler, A.; Powerski, M.J.; Elgeti, F.; Huppertz, A.; Roettgen, R.; Marnitz, T.; Wichlas, F.

    2012-01-01

    Purpose: To assess the costs and diagnostic gain of abdominal ultrasound follow-up of polytrauma patients initially examined by whole-body computed tomography (CT). Materials and Methods: A total of 176 patients with suspected multiple trauma (126 men, 50 women; age 43.5 ± 17.4 years) were retrospectively analyzed with regard to supplementary and new findings obtained by ultrasound follow-up compared with the results of exploratory FAST (focused assessment with sonography for trauma) at admission and the findings of whole-body CT. A process model was used to document the staff, materials, and total costs of the ultrasound follow-up examinations. Results: FAST yielded 26 abdominal findings (organ injury and/or free intra-abdominal fluid) in 19 patients, while the abdominal scan of whole-body CT revealed 32 findings in 25 patients. FAST had 81 % sensitivity and 100 % specificity. Follow-up ultrasound examinations revealed new findings in 2 of the 25 patients with abdominal injuries detected with initial CT. In the 151 patients without abdominal injuries in the initial CT scan, ultrasound follow-up did not yield any supplementary or new findings. The total costs of an ultrasound follow-up examination were EUR 28.93. The total costs of all follow-up ultrasound examinations performed in the study population were EUR 5658.23. Conclusion: Follow-up abdominal ultrasound yields only a low overall diagnostic gain in polytrauma patients in whom initial CT fails to detect any abdominal injuries but incurs high personnel expenses for radiological departments. (orig.)

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  17. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

    Science.gov (United States)

    Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir

    2017-08-01

    To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.

  18. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  20. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing

    International Nuclear Information System (INIS)

    Ramamurthy, Senthil; D’Orsi, Carl J; Sechopoulos, Ioannis

    2016-01-01

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360° with a perforated tungsten plate in the path of the x-ray beam. To make patient testing feasible, a wirelessly controlled electronic positioner for the tungsten plate was designed and added to a breast CT system. Other improvements to the algorithm were implemented, including automated exclusion of non-valid primary estimate points and the use of a different approximation method to estimate the full scatter signal. To evaluate the effectiveness of the algorithm, evaluation of the resulting image quality was performed with a breast phantom and with nine patient images. The improvements in the algorithm resulted in the avoidance of introduction of artifacts, especially at the object borders, which was an issue in the previous implementation in some cases. Both contrast, in terms of signal difference and signal difference-to-noise ratio were improved with the proposed method, as opposed to with the correction algorithm incorporated in the system, which does not recover contrast. Patient image evaluation also showed enhanced contrast, better cupping correction, and more consistent voxel values for the different tissues. The algorithm also reduces artifacts present in reconstructions of non-regularly shaped breasts. With the implemented hardware and software improvements, the proposed method can be reliably used during patient breast CT imaging, resulting in improvement of image quality, no introduction of artifacts, and in some cases reduction of artifacts already present. The impact of the algorithm on actual clinical performance for detection, diagnosis and other clinical tasks in breast imaging remains to be evaluated. (paper)

  1. Computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.

    1989-01-01

    This paper reports on computed tomographic (CT) scanning which has improved computer-assisted imaging modalities for radiologic diagnosis. The advantage of this modality is its ability to image thin cross-sectional planes of the body, thus uncovering density information in three dimensions without tissue superposition problems. Because this enables vastly superior imaging of soft tissues in the brain and body, CT scanning was immediately successful and continues to grow in importance as improvements are made in speed, resolution, and cost efficiency. CT scanners are used for general purposes, and the more advanced machines are generally preferred in large hospitals, where volume and variety of usage justifies the cost. For imaging in the abdomen, a scanner with a rapid speed is preferred because peristalsis, involuntary motion of the diaphram, and even cardiac motion are present and can significantly degrade image quality. When contrast media is used in imaging to demonstrate scanner, immediate review of images, and multiformat hardcopy production. A second console is reserved for the radiologist to read images and perform the several types of image analysis that are available. Since CT images contain quantitative information in terms of density values and contours of organs, quantitation of volumes, areas, and masses is possible. This is accomplished with region-of- interest methods, which involve the electronic outlining of the selected region of the television display monitor with a trackball-controlled cursor. In addition, various image- processing options, such as edge enhancement (for viewing fine details of edges) or smoothing filters (for enhancing the detectability of low-contrast lesions) are useful tools

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  3. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  6. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management

  7. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  8. Evaluation of diffuse large B-cell lymphoma patients with 64-slice multidetector computed tomography versus 18FDG positron emission tomography/computed tomography in initial staging and restaging after treatment.

    Science.gov (United States)

    Gómez León, Nieves; Vega, Gema; Rodríguez-Vigil Junco, Beatriz; Suevos Ballesteros, Carlos

    2018-04-25

    To prospectively compare the accuracy in initial staging and end-of-treatment restaging of diffuse large B-cell lymphoma (DLBCL) between 64-slice multidetector computed tomography (64MDCT) and 18FDG positron emission tomography/computed tomography (18FGD PET/CT) with intravenous contrast injection. Randomised and blind controlled clinical multicentric trial that included biopsy-proven DLBCL patients. Seventy-two patients from five different hospitals in the region of Madrid, Spain, were enrolled in the study between January 2012 and June 2015. Thirty-six were randomly allocated to 18FDG PET/TC and the other 36 to 64MDCT for initial staging and end-of-treatment restaging. A nuclear medicine physician and a radiologist independently analysed 18FDG PET/TC images and reached an agreement post-hoc. 64MDCT images were separately evaluated by a different radiologist. Every set of images was compared to the reference standard that included clinical data, complementary tests and follow-up. The study was approved by participating centres' ethics committees and written informed consent was obtained from all the participants. A good agreement was observed between both diagnostic techniques and the reference standard in initial staging [18FDG PET/CT (k=0.5) and 64MDCT (k=0.6)], although only the 18FDG PET/TC showed a good agreement with the reference standard for the end-of-treatment restaging (k=0.7). In DLBCL, both 18FDG PET/TC and 64MDCT have shown good agreement with the reference standard in initial staging. Nevertheless, 18FDG PET/CT has shown to be superior to 64MDCT in end-of-treatment response assessment. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  10. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  11. Initial results from a prototype whole-body photon-counting computed tomography system.

    Science.gov (United States)

    Yu, Z; Leng, S; Jorgensen, S M; Li, Z; Gutjahr, R; Chen, B; Duan, X; Halaweish, A F; Yu, L; Ritman, E L; McCollough, C H

    X-ray computed tomography (CT) with energy-discriminating capabilities presents exciting opportunities for increased dose efficiency and improved material decomposition analyses. However, due to constraints imposed by the inability of photon-counting detectors (PCD) to respond accurately at high photon flux, to date there has been no clinical application of PCD-CT. Recently, our lab installed a research prototype system consisting of two x-ray sources and two corresponding detectors, one using an energy-integrating detector (EID) and the other using a PCD. In this work, we report the first third-party evaluation of this prototype CT system using both phantoms and a cadaver head. The phantom studies demonstrated several promising characteristics of the PCD sub-system, including improved longitudinal spatial resolution and reduced beam hardening artifacts, relative to the EID sub-system. More importantly, we found that the PCD sub-system offers excellent pulse pileup control in cases of x-ray flux up to 550 mA at 140 kV, which corresponds to approximately 2.5×10 11 photons per cm 2 per second. In an anthropomorphic phantom and a cadaver head, the PCD sub-system provided image quality comparable to the EID sub-system for the same dose level. Our results demonstrate the potential of the prototype system to produce clinically-acceptable images in vivo .

  12. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    Science.gov (United States)

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  13. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

    International Nuclear Information System (INIS)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao; Failla, Bruna Bonaventura

    2013-01-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  16. Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography.

    Science.gov (United States)

    Benz, Robyn Melanie; Garcia, Meritxell Alzamora; Amsler, Felix; Voigt, Johannes; Fieselmann, Andreas; Falkowski, Anna Lucja; Stieltjes, Bram; Hirschmann, Anna

    2018-01-01

    Phantom-based initial performance assessment of a prototype three-dimensional (3-D) x-ray system and comparison of 3-D tomography with computed tomography (CT) were proposed. A 3-D image quality phantom was scanned with a prototype version of 3-D cone-beam CT imaging implemented on a twin robotic x-ray system using three trajectories (163 deg = table, 188 deg = upright, and 200 deg = side), six tube voltages (60, 70, 81, 90, 100, and 121 kV), and four detector doses (0.348, 0.696, 1.740, and [Formula: see text]). CT was obtained with a clinical protocol. Spatial resolution (line pairs/cm) and soft-tissue-contrast resolution were assessed by two independent readers. Radiation dose was assessed. Descriptive and analysis of variance (ANOVA) ([Formula: see text]) were performed. With 3-D tomography, a maximum of 16 lp/cm was visible and best soft-tissue-contrast resolution was 2 mm at 30 Hounsfield units (HU) for 160 projections. With CT, 10 lp/cm was visible and soft-tissue-contrast resolution was 4 mm at 20 HU. The upright trajectory yielded significantly better spatial resolution and soft tissue contrast, and the side trajectory yielded significantly higher soft tissue contrast than the table trajectory ([Formula: see text]). Radiation dose was higher in 3-D tomography (45 to 704 mGycm) than CT (44 mGycm). Three-dimensional tomography renders overall equal or higher spatial resolution and comparable soft tissue contrast to CT for medium- and high-dose protocols in the side and upright trajectories, but with higher radiation doses.

  17. Is it time to scrap Scadding and adopt computed tomography for initial evaluation of sarcoidosis? [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Andrew Levy

    2018-05-01

    Full Text Available In this review, we argue for the use of high-resolution computed tomography (HRCT over chest X-ray in the initial evaluation of patients with sarcoidosis. Chest X-ray, which has long been used to classify disease severity and offer prognostication in sarcoidosis, has clear limitations compared with HRCT, including wider interobserver variability, a looser association with lung function, and poorer sensitivity to detect important lung manifestations of sarcoidosis. In addition, HRCT offers a diagnostic advantage, as it better depicts targets for biopsy, such as mediastinal/hilar lymphadenopathy and focal parenchymal disease. Newer data suggest that specific HRCT findings may be associated with important prognostic outcomes, such as increased mortality. As we elaborate in this update, we strongly recommend the use of HRCT in the initial evaluation of the patient with sarcoidosis.

  18. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  8. Resource utilization and costs during the initial years of lung cancer screening with computed tomography in Canada.

    Science.gov (United States)

    Cressman, Sonya; Lam, Stephen; Tammemagi, Martin C; Evans, William K; Leighl, Natasha B; Regier, Dean A; Bolbocean, Corneliu; Shepherd, Frances A; Tsao, Ming-Sound; Manos, Daria; Liu, Geoffrey; Atkar-Khattra, Sukhinder; Cromwell, Ian; Johnston, Michael R; Mayo, John R; McWilliams, Annette; Couture, Christian; English, John C; Goffin, John; Hwang, David M; Puksa, Serge; Roberts, Heidi; Tremblay, Alain; MacEachern, Paul; Burrowes, Paul; Bhatia, Rick; Finley, Richard J; Goss, Glenwood D; Nicholas, Garth; Seely, Jean M; Sekhon, Harmanjatinder S; Yee, John; Amjadi, Kayvan; Cutz, Jean-Claude; Ionescu, Diana N; Yasufuku, Kazuhiro; Martel, Simon; Soghrati, Kamyar; Sin, Don D; Tan, Wan C; Urbanski, Stefan; Xu, Zhaolin; Peacock, Stuart J

    2014-10-01

    It is estimated that millions of North Americans would qualify for lung cancer screening and that billions of dollars of national health expenditures would be required to support population-based computed tomography lung cancer screening programs. The decision to implement such programs should be informed by data on resource utilization and costs. Resource utilization data were collected prospectively from 2059 participants in the Pan-Canadian Early Detection of Lung Cancer Study using low-dose computed tomography (LDCT). Participants who had 2% or greater lung cancer risk over 3 years using a risk prediction tool were recruited from seven major cities across Canada. A cost analysis was conducted from the Canadian public payer's perspective for resources that were used for the screening and treatment of lung cancer in the initial years of the study. The average per-person cost for screening individuals with LDCT was $453 (95% confidence interval [CI], $400-$505) for the initial 18-months of screening following a baseline scan. The screening costs were highly dependent on the detected lung nodule size, presence of cancer, screening intervention, and the screening center. The mean per-person cost of treating lung cancer with curative surgery was $33,344 (95% CI, $31,553-$34,935) over 2 years. This was lower than the cost of treating advanced-stage lung cancer with chemotherapy, radiotherapy, or supportive care alone, ($47,792; 95% CI, $43,254-$52,200; p = 0.061). In the Pan-Canadian study, the average cost to screen individuals with a high risk for developing lung cancer using LDCT and the average initial cost of curative intent treatment were lower than the average per-person cost of treating advanced stage lung cancer which infrequently results in a cure.

  9. Primary pulmonary lymphoma-role of fluoro-deoxy-glucose positron emission tomography-computed tomography in the initial staging and evaluating response to treatment - case reports and review of literature

    International Nuclear Information System (INIS)

    Agarwal, Krishan Kant; Dhanapathi, Halanaik; Nazar, Aftab Hasan; Kumar, Rakesh

    2016-01-01

    Primary pulmonary lymphoma (PPL) is an uncommon entity of non-Hodgkin lymphoma, which accounts for <1% of all cases of lymphoma. We present two rare cases of PPL of diffuse large B-cell lymphoma, which underwent 18 fluorine fluoro-deoxy-glucose positron emission tomography-computed tomography for initial staging and response evaluation after chemotherapy

  10. Contrast-enhanced [18F] fluorodeoxyglucose-positron emission tomography-computed tomography as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin

    International Nuclear Information System (INIS)

    Jain, Avani; Srivastava, Madhur Kumar; Pawaskar, Alok Suresh; Shelley, Simon; Elangovan, Indirani; Jain, Hasmukh; Pandey, Somnath; Kalal, Shilpa; Amalachandran, Jaykanth

    2005-01-01

    To evaluate the advantages of contrast enhanced F-18-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-contrast enhanced CT [CECT]) when used as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin (MUO). A total of 243 patients with fine needle aspiration cytology/biopsy proven MUO were included in this prospective study. Patients who were thoroughly evaluated for primary or primary tumor was detected by any other investigation were excluded from the analysis. Totally, 163 patients with pathological diagnosis of malignancy but no apparent sites of the primary tumor were finally selected for analysis. The site of probable primary malignancy suggested by PET-CECT was confirmed by biopsy/follow-up. PET-CECT suggested probable site of primary in 128/163 (78.52%) patients. In 30/35 remaining patients, primary tumor was not detected even after extensive work-up. In 5 patients, where PET-CECT was negative, primary was found on further extensive investigations or follow-up. The sensitivity, specificity, positive predictive value and negative predictive value of the study were 95.76%, 66.67%, 88.28% and 85.71% respectively. F-18 FDG PET-CECT aptly serves the purpose of initial imaging modality owing to high sensitivity, negative and positive predictive value. PET-CECT not only surveys the whole body for the primary malignancy but also stages the disease accurately. Use of contrast improves the diagnostic utility of modality as well as help in staging of the primary tumor. Although benefits of using PET-CECT as initial diagnostic modality are obvious from this study, there is a need for a larger study comparing conventional methods for diagnosing primary in patients with MUO versus PET-CECT

  11. Contrast-enhanced [18F] fluorodeoxyglucose-positron emission tomography-computed tomography as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin.

    Science.gov (United States)

    Jain, Avani; Srivastava, Madhur Kumar; Pawaskar, Alok Suresh; Shelley, Simon; Elangovan, Indirani; Jain, Hasmukh; Pandey, Somnath; Kalal, Shilpa; Amalachandran, Jaykanth

    2015-01-01

    To evaluate the advantages of contrast enhanced F-18-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-contrast enhanced CT [CECT]) when used as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin (MUO). A total of 243 patients with fine needle aspiration cytology/biopsy proven MUO were included in this prospective study. Patients who were thoroughly evaluated for primary or primary tumor was detected by any other investigation were excluded from the analysis. Totally, 163 patients with pathological diagnosis of malignancy but no apparent sites of the primary tumor were finally selected for analysis. The site of probable primary malignancy suggested by PET-CECT was confirmed by biopsy/follow-up. PET-CECT suggested probable site of primary in 128/163 (78.52%) patients. In 30/35 remaining patients, primary tumor was not detected even after extensive work-up. In 5 patients, where PET-CECT was negative, primary was found on further extensive investigations or follow-up. The sensitivity, specificity, positive predictive value and negative predictive value of the study were 95.76%, 66.67%, 88.28% and 85.71% respectively. F-18 FDG PET-CECT aptly serves the purpose of initial imaging modality owing to high sensitivity, negative and positive predictive value. PET-CECT not only surveys the whole body for the primary malignancy but also stages the disease accurately. Use of contrast improves the diagnostic utility of modality as well as help in staging of the primary tumor. Although benefits of using PET-CECT as initial diagnostic modality are obvious from this study, there is a need for a larger study comparing conventional methods for diagnosing primary in patients with MUO versus PET-CECT.

  12. Traumatic midline subarachnoid hemorrhage on initial computed tomography as a marker of severe diffuse axonal injury.

    Science.gov (United States)

    Mata-Mbemba, Daddy; Mugikura, Shunji; Nakagawa, Atsuhiro; Murata, Takaki; Ishii, Kiyoshi; Kushimoto, Shigeki; Tominaga, Teiji; Takahashi, Shoki; Takase, Kei

    2018-01-05

    OBJECTIVE The objective of this study was to test the hypothesis that midline (interhemispheric or perimesencephalic) traumatic subarachnoid hemorrhage (tSAH) on initial CT may implicate the same shearing mechanism that underlies severe diffuse axonal injury (DAI). METHODS The authors enrolled 270 consecutive patients (mean age [± SD] 43 ± 23.3 years) with a history of head trauma who had undergone initial CT within 24 hours and brain MRI within 30 days. Six initial CT findings, including intraventricular hemorrhage (IVH) and tSAH, were used as candidate predictors of DAI. The presence of tSAH was determined at the cerebral convexities, sylvian fissures, sylvian vallecula, cerebellar folia, interhemispheric fissure, and perimesencephalic cisterns. Following MRI, patients were divided into negative and positive DAI groups, and were assigned to a DAI stage: 1) stage 0, negative DAI; 2) stage 1, DAI in lobar white matter or cerebellum; 3) stage 2, DAI involving the corpus callosum; and 4) stage 3, DAI involving the brainstem. Glasgow Outcome Scale-Extended (GOSE) scores were obtained in 232 patients. RESULTS Of 270 patients, 77 (28.5%) had DAI; tSAH and IVH were independently associated with DAI (p GOSE score at both hospital discharge and after 6 months. CONCLUSIONS Midline tSAH could implicate the same shearing mechanism that underlies severe DAI, for which midline tSAH on initial CT is a probable surrogate.

  13. Computed tomography, lymphography, and staging laparotomy: correlations in initial staging of Hodgkin disease

    Energy Technology Data Exchange (ETDEWEB)

    Castellino, R.A.; Hoppe, R.T.; Blank, N.; Young, S.W.; Neumann, C.; Rosenberg, S.A.; Kaplan, H.S.

    1984-07-01

    One hundred twenty-one patients with newly diagnosed, previously untreated Hodgkin disease underwent abdominal and pelvic computed tomographic (CT) scanning and bipedal lymphography. These studies were followed by staging laparotomy, which included biopsy of the liver, retroperitoneal and mesenteric lymph nodes, and splenectomy. Correlation of the results of the imaging studies with the histopathologic diagnoses revealed a small - but significant - increased accuracy of lymphography compared with CT in assessing the retroperitoneal lymph nodes. The theoretical advantages of CT scanning in detecting lymphomatous deposits in lymph nodes about the celiac axis and the mesentery, or in the liver and spleen, were not confirmed.

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  18. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  19. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  20. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  3. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  4. Computed tomography during cardiopulmonary resuscitation using automated chest compression devices - an initial study

    International Nuclear Information System (INIS)

    Wirth, Stefan; Koerner, Markus; Treitl, Marcus; Linsenmaier, Ulrich; Reiser, Maximilian F.; Leidel, Bernd A.; Jaschkowitz, Thomas; Kanz, Karl G.

    2009-01-01

    The purpose of the study was to evaluate both CT image quality in a phantom study and feasibility in an initial case series using automated chest compression (A-CC) devices for cardiopulmonary resuscitation (CPR). Multidetector CT (MDCT) of a chest/heart phantom (Thorax-CCI, QRM, Germany) was performed with identical protocols of the phantom alone (S), the phantom together with two different A-CC devices (A: AutoPulse, Zoll, Germany; L: LUCAS, Jolife, Sweden), and the phantom with a LUCAS baseplate, but without the compression unit (L-bp). Nine radiologists evaluated image noise quantitatively (n=244 regions, Student's t-test) and also rated image quality subjectively (1-excellent to 6-inadequate, Mann-Whitney U-test). Additionally, three patients during prolonged CPR underwent CT with A-CC devices. Mean image noise of S was increased by 1.21 using L-bp, by 3.62 using A, and by 5.94 using L (p<0.01 each). Image quality was identical using S and L-bp (1.64 each), slightly worse with A (1.83), and significantly worse with L (2.97, p<0.001). In all patient cases the main lesions were identified, which led to clinical key decisions. Image quality was excellent with L-bp and good with A. Under CPR conditions initial cases indicate that MDCT diagnostics supports either focused treatment or the decision to terminate efforts. (orig.)

  5. Suppression of intensity transition artifacts in statistical x-ray computer tomography reconstruction through Radon inversion initialization

    International Nuclear Information System (INIS)

    Zbijewski, Wojciech; Beekman, Freek J.

    2004-01-01

    Statistical reconstruction (SR) methods provide a general and flexible framework for obtaining tomographic images from projections. For several applications SR has been shown to outperform analytical algorithms in terms of resolution-noise trade-off achieved in the reconstructions. A disadvantage of SR is the long computational time required to obtain the reconstructions, in particular when large data sets characteristic for x-ray computer tomography (CT) are involved. As was shown recently, by combining statistical methods with block iterative acceleration schemes [e.g., like in the ordered subsets convex (OSC) algorithm], the reconstruction time for x-ray CT applications can be reduced by about two orders of magnitude. There are, however, some factors lengthening the reconstruction process that hamper both accelerated and standard statistical algorithms to similar degree. In this simulation study based on monoenergetic and scatter-free projection data, we demonstrate that one of these factors is the extremely high number of iterations needed to remove artifacts that can appear around high-contrast structures. We also show (using the OSC method) that these artifacts can be adequately suppressed if statistical reconstruction is initialized with images generated by means of Radon inversion algorithms like filtered back projection (FBP). This allows the reconstruction time to be shortened by even as much as one order of magnitude. Although the initialization of the statistical algorithm with FBP image introduces some additional noise into the first iteration of OSC reconstruction, the resolution-noise trade-off and the contrast-to-noise ratio of final images are not markedly compromised

  6. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  8. Comparison of initial high resolution computed tomography features in viral pneumonia between metapneumovirus infection and severe acute respiratory syndrome

    International Nuclear Information System (INIS)

    Wong, Cheuk Kei Kathy; Lai, Vincent; Wong, Yiu Chung

    2012-01-01

    Objective: To review and compare initial high resolution computed tomography (HRCT) findings in patients with metapneumovirus pneumonia and severe acute respiratory syndrome (SARS-Coronovirus). Materials and methods: 4 cases of metapneumovirus pneumonia (mean age of 52.3 years) in an institutional outbreak (Castle Peak Hospital) in 2008 and 38 cases of SARS-coronovirus (mean age of 39.6 years) admitted to Tuen Mun hospital during an epidemic outbreak in 2003 were included. HRCT findings of the lungs for all patients were retrospectively reviewed by two independent radiologists. Results: In the metapneumovirus group, common HRCT features were ground glass opacities (100%), consolidation (100%), parenchymal band (100%), bronchiectasis (75%). Crazy paving pattern was absent. They were predominantly subpleural and basal in location and bilateral involvement was observed in 50% of patients. In the SARS group, common HRCT features were ground glass opacities (92.1%), interlobular septal thickening (86.8%), crazy paving pattern (73.7%) and consolidation (68%). Bronchiectasis was not seen. Majority of patient demonstrated segmental or lobar in distribution and bilateral involvement was observed in 44.7% of patients. Pleural effusion and lymphadenopathy were of consistent rare features in both groups. Conclusion: Ground glass opacities, interlobular septal thickening and consolidations were consistent HRCT manifestations in both metapneumovirus infection and SARS. The presence of bronchiectasis (0% in SARS) may point towards metapneumovirus while crazy paving pattern is more suggestive of SARS.

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  10. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  11. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  12. Volumetric Single-Beat Coronary Computed Tomography Angiography: Relationship of Image Quality, Heart Rate, and Body Mass Index. Initial Patient Experience With a New Computed Tomography Scanner.

    Science.gov (United States)

    Latif, Muhammad Aamir; Sanchez, Frank W; Sayegh, Karl; Veledar, Emir; Aziz, Muhammad; Malik, Rehan; Haider, Imran; Agatston, Arthur S; Batlle, Juan C; Janowitz, Warren; Peña, Constantino; Ziffer, Jack A; Nasir, Khurram; Cury, Ricardo C

    2016-01-01

    Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and

  13. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  14. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  15. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  16. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  17. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  18. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  19. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  20. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  1. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  2. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  3. Usefulness of multidetector computed tomography (MDCT) for the initial evaluation of multiple blunt trauma of the trunk

    International Nuclear Information System (INIS)

    Hagiwara, Shuichi; Ogino, Takashi; Isaka, Akira; Takahashi, Yuga; Nameki, Tarou; Kagoshima, Kaie; Yamada, Takurou; Ishihara, Kouichi; Iino, Yuichi

    2008-01-01

    Focused assessment with sonography for trauma (FAST) is useful for detecting hemoperitoneum (HE) in trauma patients in the emergency room (ER), but, patients' condition cannot be evaluated adequately by FAST alone. CT is useful for the diagnosis of multiple trauma, but has certain drawbacks. We evaluated the utility of multidetector computed tomography (MDCT) as the initial tool for proper diagnosis and treatment planning of multiple trauma patients. We retrospectively analyzed 128 cases treated in ER of Gunma University Hospital between April 1, 2005 and December 31, 2006, and they were hospital patients were hospitalized with blunt multiple trauma. We analyzed the sensitivity, specificity, and accuracy of FAST, compiled MDCT finding, lifesaving treatment, and outcome. Eight patients were FAST positive, and 7 of the 8 were scanned by MDCT. There were 120 patients were FAST negative patients, 23 of the 120 were MDCT-negative, despite visceral injury, however 9 of the 120 had visceral injury by MDCT findings. Damage control surgery without MDCT was performed in one case, but the patient died after surgery. Six of the patients in the HE-positive group had really HE. One of the 6 died while a waiting surgery, transcatheter arterial embolization (TAE) was performed in three patients, and one person out of the 3 died. The course of the remaining 2 patients was monitored, and they are alive. A patient in the HE-negative group with bladder rupture required surgery. There were 120 patients in the FAST-negative group. One of the 6 patients in the HE-positive subgroup died while a waiting surgery. One patient required chest and pericardial drainage. TAE was performed in 2 patients, and the remaining 6 were monitored and are alive. There were 23 FAST-negative patients patients who had visceral injury. Five of them required chest drainage, one received TAE, 17 were monitored, and all of the 23 are alive. There were 14 cases of pelvic fracture alone, and all of them were FAST

  4. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  5. Clinical role of 18F-fluorodeoxyglucose positron emission tomography/computed tomography in post-operative follow up of gastric cancer: Initial results

    Institute of Scientific and Technical Information of China (English)

    Long Sun; Xin-Hui Su; Yong-Song Guan; Wei-Ming Pan; Zuo-Ming Luo; Ji-Hong Wei; Hua Wu

    2008-01-01

    AIM: To evaluate the clinical role of 18F-fluorodeo-xyglucose positron emission and computed tomography(18F-FDG PET/CT) in detection of gastric cancer recur rence after initial surgical resection.METHODS: In the period from January 2007 to May 2008, 23 patients who had previous surgical resection of histopathologically diagnosed gastric cancer underwent a total of 25 18F-FDG PET/CT scans as follow-up visits in our center. The standard of reference for tumor recurrence consisted of histopathologic confirmation or clinical follow-up information for at least 5 mo after PET/CT examinations.RESULTS: PET/Cr was positive in 14 patients (61%)and negative in 9 (39%). When correlated with final diagnosis, which was confirmed by histopathologic evidence of tumor recurrence in 8 of the 23 patients(35%) and by clinical follow-up in 15 (65%), PET/CT was true positive in 12 patients, false positive in 2,true negative in 8 and false negative in 2. Overall,the accuracy of PET/CT was 82.6%, the negative predictive value (NPV) was 77.7%, and the positive predictive value (PPV) was 85.7%. The 2 false positive PET/CT findings were actually chronic inflammatory tissue lesions. For the two patients with false negative PET/CT, the final diagnosis was recurrence of mucinous adenocarcinoma in the anastomosis in one patient and abdominal wall metastasis in the other. Importantly,PET/CT revealed true-positive findings in 11 (47.8%)patients who had negative or no definite findings by CT. PET/CT revealed extra-abdominal metastases in 7 patients and additional esophageal carcinoma in onepatient. Clinical treatment decisions were changed in 7 (30.4%) patients after introducing PET/CT into theirconventional post-operative follow-up program.CONCLUSION: Whole body 18F-FDG PET/CT was highly effective in discriminating true recurrence in post-operative patients with gastric cancer and had important impacts on clinical decisions in a considerable portion of patients.

  6. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  7. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  8. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  9. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  10. Incidental detection of prostate-specific antigen-negative metastatic prostate cancer initially presented with solitary pulmonary nodule on fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Erdogan, Ezgi Basak; Buyukpinarbasili, Nur; Ziyade, Sedat; Akman, Tolga; Turk, Haci Mehmet; Aydin, Mehmet

    2005-01-01

    A 71-year-old male patient with solitary pulmonary nodule underwent fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) showing slightly increased FDG uptake in this nodule. In addition, PET/CT detected hypermetabolic sclerotic bone lesions in the right second rib and 7 th thoracic vertebrae, which were interpreted as possible metastases, and mildly increased FDG uptake in the prostate gland highly suspicious of malignancy. The patient's prostate-specific antigen (PSA) level was within normal range (3.8 ng/dL). The histopathological examination of the lung nodule and right second rib lesion proved metastases from prostate cancer, then the prostate biopsy-confirmed prostate adenocarcinoma. The unique feature of this case is to emphasize the importance of performing PET/CT for solitary pulmonary nodule in detecting PSA-negative metastatic prostate cancer. This case indicated that it should be kept in mind that, even if the PSA is negative, a lung metastasis of prostate cancer may be an underlying cause in patients evaluated for solitary pulmonary nodule by FDG PET/CT

  11. Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results

    International Nuclear Information System (INIS)

    Szczykutowicz, Timothy P.; Mistretta, Charles A.

    2013-01-01

    reduction of ≈4 times relative to flat field CT. The dynamic range for the DBA prototype was 3.7 compared to 84.2 for the flat field scan. Conclusions: Based on the results presented in this paper and the companion paper [T. Szczykutowicz and C. Mistretta, “Design of a digital beam attenuation system for computed tomography. Part I. System design and simulation framework,” Med. Phys. 40, 021905 (2013)], FFMCT implemented via the DBA device seems feasible and should result in both a dose reduction and an improvement in image quality as judged by noise uniformity and scatter reduction. In addition, the dynamic range reduction achievable using the DBA may allow photon counting imaging to become a clinical reality. This study may allow for yet another step to be taken in the field of patient specific dose modulation.

  12. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Fairbairn, I.A.

    1984-01-01

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  13. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  14. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  15. Volume-based quantification using dual-energy computed tomography in the differentiation of thymic epithelial tumours: an initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Suyon; Hur, Jin; Im, Dong Jin; Suh, Young Joo; Hong, Yoo Jin; Lee, Hye-Jeong; Kim, Young Jin; Choi, Byoung Wook [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Seoul (Korea, Republic of); Han, Kyunghwa [Yonsei University College of Medicine, Yonsei Biomedical Research Institute, Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Seoul (Korea, Republic of); Kim, Dae Joon; Lee, Chang Young [Yonsei University College of Medicine, Department of Thoracic and Cardiovascular Surgery, Seoul (Korea, Republic of); Shin, Ha Young [Yonsei University College of Medicine, Department of Neurology, Seoul (Korea, Republic of)

    2017-05-15

    To investigate the diagnostic value of dual-energy computed tomography (DECT) in differentiating between low- and high-risk thymomas and thymic carcinomas. Our institutional review board approved this study, and patients provided informed consent. We prospectively enrolled 37 patients (20 males, mean age: 55.6 years) with thymic epithelial tumour. All patients underwent DECT. For quantitative analysis, two reviewers measured the following tumour parameters: CT attenuation value in contrast Hounsfield units (CHU), iodine-related HU and iodine concentration (mg/ml). Pathological results confirmed the final diagnosis. Of the 37 thymic tumours, 23 (62.2 %) were low-risk thymomas, five (13.5 %) were high-risk thymomas and nine (24.3 %) were thymic carcinomas. According to quantitative analysis, iodine-related HU and iodine concentration were significantly different among low-risk thymomas, high-risk thymomas and thymic carcinomas (median: 29.78 HU vs. 14.55 HU vs. 19.95 HU, p = 0.001 and 1.92 mg/ml vs. 0.99 mg/ml vs. 1.18 mg/ml, p < 0.001, respectively). DECT using a quantitative analytical method based on iodine concentration measurement can be used to differentiate among thymic epithelial tumours using single-phase scanning. (orig.)

  16. Adult congenital heart disease imaging with second-generation dual-source computed tomography: initial experiences and findings.

    Science.gov (United States)

    Ghoshhajra, Brian B; Sidhu, Manavjot S; El-Sherief, Ahmed; Rojas, Carlos; Yeh, Doreen Defaria; Engel, Leif-Christopher; Liberthson, Richard; Abbara, Suhny; Bhatt, Ami

    2012-01-01

    Adult congenital heart disease patients present a unique challenge to the cardiac imager. Patients may present with both acute and chronic manifestations of their complex congenital heart disease and also require surveillance for sequelae of their medical and surgical interventions. Multimodality imaging is often required to clarify their anatomy and physiology. Radiation dose is of particular concern in these patients with lifelong imaging needs for their chronic disease. The second-generation dual-source scanner is a recently available advanced clinical cardiac computed tomography (CT) scanner. It offers a combination of the high-spatial resolution of modern CT, the high-temporal resolution of dual-source technology, and the wide z-axis coverage of modern cone-beam geometry CT scanners. These advances in technology allow novel protocols that markedly reduce scan time, significantly reduce radiation exposure, and expand the physiologic imaging capabilities of cardiac CT. We present a case series of complicated adult congenital heart disease patients imaged by the second-generation dual-source CT scanner with extremely low-radiation doses and excellent image quality. © 2012 Wiley Periodicals, Inc.

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  18. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  4. Emergency radiological examination of the externally stabilized pelvis--there is a catch to it: lessons learned from two cases with symphyseal disruption despite initial inconspicuous computed tomography.

    Science.gov (United States)

    Bayer, Jörg; Hammer, Thorsten; Maier, Dirk; Südkamp, Norbert Paul; Hauschild, Oliver

    2016-03-12

    Preclinical and early clinical external pelvic stabilization using commercially available devices has become common in trauma patient care. Thus, in the emergency department an increasing number of patients will undergo radiographic evaluation of the externally stabilized pelvis to exclude injuries. While reports exist where injuries to the pelvis were elusive to radiological examination due to the pelvic immobilization we elaborate on an algorithm to remove an external pelvic stabilizing device, prevent delayed diagnosis of pelvic disruption and thus increase patient safety. We report on two patients with external pelvic stabilization presenting with an inconspicuous pubic symphysis on initial pelvic computed tomography scans. The first patient was an otherwise healthy 51-year old male being run over by his own car. He received external pelvic stabilization in the emergency department. The second patient was a 36-year old male falling from a ladder. In this patient external pelvic stabilization was performed at the scene. In the first patient no pelvic injury was obvious on computed tomography. In the second patient pelvic fractures were diagnosed, yet the presentation of the pubic symphysis appeared normal. Nevertheless, complete symphyseal disruption was diagnosed in both of them upon removal of the external pelvic stabilization and consequently required internal fixation. Based on our experience we propose an algorithm to "clear the initially immobilized pelvis" in an effort to minimize the risk of missing a serious pelvic injury and increase patient safety. This is of significant importance to orthopedic trauma surgeons and emergency physicians taking care of injured patients.

  5. High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

    International Nuclear Information System (INIS)

    Rist, Carsten; Nikolaou, Konstantin; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.; Flohr, Thomas

    2006-01-01

    The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen. (orig.)

  6. The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Winnie; Cho, Young-Bin [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Ansell, Steve [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Laperriere, Normand; Ménard, Cynthia; Millar, Barbara-Ann [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Zadeh, Gelareh [Division of Neurosurgery, University of Toronto University Health Network, Toronto Western Hospital, Toronto, Ontario (Canada); Macfeeters-Hamilton Centre for Neuro-oncology, Ontario Cancer Institute, Toronto, Ontario (Canada); Kongkham, Paul; Bernstein, Mark [Division of Neurosurgery, University of Toronto University Health Network, Toronto Western Hospital, Toronto, Ontario (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada); Chung, Caroline, E-mail: caroline.chung.md@gmail.com [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada)

    2016-09-01

    Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction

  7. The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

    International Nuclear Information System (INIS)

    Li, Winnie; Cho, Young-Bin; Ansell, Steve; Laperriere, Normand; Ménard, Cynthia; Millar, Barbara-Ann; Zadeh, Gelareh; Kongkham, Paul; Bernstein, Mark; Jaffray, David A.; Chung, Caroline

    2016-01-01

    Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction

  8. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... ring, called a gantry. The computer workstation that processes the imaging information is located in a separate ... follows a spiral path. A special computer program processes this large volume of data to create two- ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ... ray beam follows a spiral path. A special computer program processes this large volume of data to ...

  14. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  15. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  16. Emission computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99 /sup m/Tc, 201 Tl, 123 I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... diagnose sinusitis . evaluate sinuses that are filled with fluid or thickened sinus membranes . detect the presence of ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... of the Sinuses? CT is usually the first test ordered when a sinus tumor is suspected. If ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to reduce the risk of an allergic reaction. These medications must be taken 12 hours prior to ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... to you, revolve around you during the imaging process. You will be alone in the exam room ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... cause blurring of the images and degrade the quality of the examination the same way that it ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... artifacts on the images. This loss of image quality can resemble the blurring seen on a photograph ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  20. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  1. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  3. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  4. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  5. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  6. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  7. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  8. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  9. Errors in abdominal computed tomography

    International Nuclear Information System (INIS)

    Stephens, S.; Marting, I.; Dixon, A.K.

    1989-01-01

    Sixty-nine patients are presented in whom a substantial error was made on the initial abdominal computed tomography report. Certain features of these errors have been analysed. In 30 (43.5%) a lesion was simply not recognised (error of observation); in 39 (56.5%) the wrong conclusions were drawn about the nature of normal or abnormal structures (error of interpretation). The 39 errors of interpretation were more complex; in 7 patients an abnormal structure was noted but interpreted as normal, whereas in four a normal structure was thought to represent a lesion. Other interpretive errors included those where the wrong cause for a lesion had been ascribed (24 patients), and those where the abnormality was substantially under-reported (4 patients). Various features of these errors are presented and discussed. Errors were made just as often in relation to small and large lesions. Consultants made as many errors as senior registrar radiologists. It is like that dual reporting is the best method of avoiding such errors and, indeed, this is widely practised in our unit. (Author). 9 refs.; 5 figs.; 1 tab

  10. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  11. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  12. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  13. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  14. Costs and role of ultrasound follow-up of polytrauma patients after initial computed tomography; Kosten und Stellenwert von Ultraschallverlaufskontrollen bei polytraumatisierten Patienten nach initialer Computertomografie

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Winkler, A.; Powerski, M.J.; Elgeti, F.; Huppertz, A.; Roettgen, R.; Marnitz, T. [Charite - Universitaetsmedizin Berlin (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Wichlas, F. [Charite - Universitaetsmedizin Berlin (Germany). Centrum fuer Muskuloskeletale Chirurgie

    2012-01-15

    Purpose: To assess the costs and diagnostic gain of abdominal ultrasound follow-up of polytrauma patients initially examined by whole-body computed tomography (CT). Materials and Methods: A total of 176 patients with suspected multiple trauma (126 men, 50 women; age 43.5 {+-} 17.4 years) were retrospectively analyzed with regard to supplementary and new findings obtained by ultrasound follow-up compared with the results of exploratory FAST (focused assessment with sonography for trauma) at admission and the findings of whole-body CT. A process model was used to document the staff, materials, and total costs of the ultrasound follow-up examinations. Results: FAST yielded 26 abdominal findings (organ injury and/or free intra-abdominal fluid) in 19 patients, while the abdominal scan of whole-body CT revealed 32 findings in 25 patients. FAST had 81 % sensitivity and 100 % specificity. Follow-up ultrasound examinations revealed new findings in 2 of the 25 patients with abdominal injuries detected with initial CT. In the 151 patients without abdominal injuries in the initial CT scan, ultrasound follow-up did not yield any supplementary or new findings. The total costs of an ultrasound follow-up examination were EUR 28.93. The total costs of all follow-up ultrasound examinations performed in the study population were EUR 5658.23. Conclusion: Follow-up abdominal ultrasound yields only a low overall diagnostic gain in polytrauma patients in whom initial CT fails to detect any abdominal injuries but incurs high personnel expenses for radiological departments. (orig.)

  15. How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kahn, Johannes; Grupp, Ulrich; Maurer, Martin

    2014-01-01

    Purpose: To evaluate the influence of different arm positions on abdominal image quality during initial whole-body CT (WBCT) in polytraumatized patients and to assess the risk of missing potentially life-threatening injuries due to arm artifacts. Materials and methods: Between July 2011 and February 2013, WBCT scans of 203 patients with arms in the abdominal area during initial WBCT were analyzed. Six different arms-down positions were defined: patients with both (group A)/one arm(s) (group B) down alongside the torso, patients with both (group C)/one arm(s) (group D) crossed in front of the upper abdomen, patients with both (group E)/one arm(s) (group F) crossed in front of the pelvic area. A group of 203 patients with elevated arms beside the head served as a control group. Two observers jointly evaluated image quality of different organ regions using a 4-point scale system. Follow-up examinations (CT scans and/or ultrasound) were analyzed to identify findings missed during initial WBCT due to reduced image quality. Results: Image quality for most of the organ regions analyzed was found to be significantly different among all groups (p < 0.05). Image quality was most severely degraded in group A, followed by groups E and C. Positioning with one arm up resulted in significantly better image quality than both arms down (p < 0.05). Overall, arms-up positioning showed significantly better image quality than arms-down positions (p < 0.05). In one case, liver hemorrhage missed in the initial WBCT because of arm artifacts, was revealed by follow-up CT. Conclusion: In WBCT arms-down positioning significantly degrades abdominal image quality and artifacts might even conceal potentially life-threatening injuries. If the patient's status does not allow elevation of both arms, image quality can benefit from raising at least one arm. Otherwise, arms should be placed in front of the upper abdomen instead of alongside the torso

  16. Industrial applications of computer tomography

    International Nuclear Information System (INIS)

    Sheng Kanglong; Qiang Yujun; Yang Fujia

    1992-01-01

    Industrial computer tomography (CT) and its application is a rapidly developing field of high technology. CT systems have been playing important roles in nondestructive testing (NDT) of products and equipment for a number of industries. Recently, the technique has advanced into the area of industrial process control, bringing even greater benefit to mankind. The basic principles and typical structure of an industrial CT system Descriptions are given of some successful CT systems for either NDT application or process control purposes

  17. Computed tomography of projectile injuries

    International Nuclear Information System (INIS)

    Jeffery, A.J.; Rutty, G.N.; Robinson, C.; Morgan, B.

    2008-01-01

    Computed tomography (CT) is a gold standard in clinical imaging but forensic professions have been slow to embrace radiological advances. Forensic applications of CT are now exponentially expanding, replacing other imaging methods. As post-mortem cross-sectional imaging increases, radiologists will fall under increasing pressure to interpret complex forensic cases involving both living and deceased patients. This review presents a wide variety of weapon and projectile types aiding interpretation of projectile injuries both in forensic and clinical practice

  18. Computed tomography in osteoid osteoma

    International Nuclear Information System (INIS)

    Vicens, J.L.; Aubspin, D.; Buchon, R.; Schoenenberger, P.; Flageat, J.

    1989-01-01

    Four cases of suspected osteoid osteoma were evaluated by computed tomography (CT). The role of CT was related, as a key diagnostic tool: radionuclide imaging is helpful in directing subsequent CT scans, which allows the study of complex anatomical sites (spine) or the analysis of atypical lesions (invisible nidus, sclerosis or lytic lesions, double nidus...). CT provides the surgeon with the exact location and extent of the lesion, and thus, CT may allow a more limited surgical resection of the involved bone [fr

  19. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  20. Computed tomography of the ossicles

    International Nuclear Information System (INIS)

    Chakeres, D.W.; Weider, D.J.

    1985-01-01

    Otologists and otolaryngologists have described in detail the disorders which are unique to the ossicles. However the anatomy and spectrum of pathology and anatomy of the ossicles are not familiar to most radiologists. Recent advances in computed tomography (CT) and a systematic approach to evaluation now allow accurate identification of even subtle abnormalities of the ossicles. We present the normal anatomy, ossicular abnormalities, and indications for computed tomographic study. Because of the greater diagnostic capability of CT, the radiologist's role has increased in evaluation and treatment planning of patients with suspected ossicular abnormalities. (orig.)

  1. Cost-Effectiveness Analysis (CEA) of Intravenous Urography (IVU) and Unenhanced Multidetector Computed Tomography (MDCT) for Initial Investigation of Suspected Acute Ureterolithiasis

    International Nuclear Information System (INIS)

    Eikefjord, E.; Askildsen, J.E.; Roervik, J.

    2008-01-01

    Background: It is important to compare the cost and effectiveness of multidetector computed tomography (MDCT) and intravenous urography (IVU) to determine the most cost-effective alternative for the initial investigation of acute ureterolithiasis. Purpose: To analyze the task-specific variable costs combined with the diagnostic effect of MDCT and IVU for patients with acute flank pain, and to determine which is most cost effective. Material and Methods: 119 patients with acute flank pain suggestive of stone disease (ureterolithiasis) were examined by both MDCT and IVU. Variable costs related to medical equipment, consumption material, equipment control, and personnel were calculated. The diagnostic effect was assessed. Results: The variable costs of MDCT versus IVU were EUR 32 and EUR 117, respectively. This significant difference was mainly due to savings in examination time, higher annual examination frequency, lower material costs, and no use of contrast media. As for diagnostic effect, MDCT proved considerably more accurate in the diagnosis of stone disease than IVU and markedly more accurate concerning differential diagnoses. Conclusion: MDCT had lower differential costs and a higher capacity to determine correctly stone disease and differential diagnoses, as compared to IVU, in patients with acute flank pain. Consequently, MDCT is a dominant alternative to IVU when evaluated exclusively from a cost-effective perspective

  2. Computed tomography of craniomandibular osteopathy in a dog

    International Nuclear Information System (INIS)

    Hudson, J.A.; Montgomery, R.D.; Hathcock, J.T.; Jarboe, J.M.

    1994-01-01

    This report describes the use of computed tomography (CT) to evaluate the tympanic bullae and angular processes of the mandible in a West Highland White Terrier with craniomandibular osteopathy. The patient presented initially for swelling of the right forelimb. The report illustrates the use of computed tomography for evaluation of craniomandibular osteopathy, initial presentation with long-bone pathology, and remarkable resolution of osseous changes

  3. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  4. The history of computed tomography

    International Nuclear Information System (INIS)

    Bull, J.

    1980-01-01

    New scientific discoveries are often made by the synthetising of other discoveries. Computed tomography is such an example. The three necessary elements were: 1/ the fact that certain simple crystals scintillate when exposed to X-rays, 2/ the advent of electronics and 3/ that of computers. The fact that X-rays cause crystals to scintillate was learnt very shortly after Roentgen's discovery, electronics and computers coming very much later. To put all these together and apply them to diagnostic radiology, and at the same time dismiss the concept so firmly ingrained in everyone's mind that an X-ray picture must be produced on photographic film, required a genius. (orig./VJ) [de

  5. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  6. Duodenal diverticulitis. computed tomography findings

    International Nuclear Information System (INIS)

    Sanchez, E.; Martin, S.; Garcia, J.; Dominguez, A.

    2001-01-01

    Duodenal diverticular occur very frequently among the general public. However, duodenal diverticulitis is a very uncommon clinical entity, the diagnosis of which requires radiological studies since the clinical signs cam mimic a great number of disease processes with different treatments. We present a case of duodenal diverticulitis in which the diagnosis according to ultrasound and computed tomography (CT) studies was confirmed intraoperatively. We also review the few cases of this entity reported in the literature. The CT findings are highly suggestive of duodenal diverticulitis given their similarity to those associated with diverticulitis at other sites. (Author) 5 refs,

  7. Mathematical foundations of computed tomography

    International Nuclear Information System (INIS)

    Smith, K.T.; Keinert, F.

    1985-01-01

    Along with a review of some of the mathematical foundations of computed tomography, the article contains new results on derivation of reconstruction formulas in a general setting encompassing all standard formulas; discussion and examples of the role of the point spread function with recipes for producing suitable ones; formulas for, and examples of, the reconstruction of certain functions of the attenuation coefficient, e.g., sharpened versions of it, some of them with the property that reconstruction at a point requires only the attenuation along rays meeting a small neighborhood of the point

  8. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  9. Brain metastases: computed tomography assessment

    International Nuclear Information System (INIS)

    Gordillo, Victoria; Yagual, Glenda; Vinueza, Clayreth

    1998-01-01

    Intracranial metastatic tumor is relatively frequent in patients with cancer from other origin. Its location and type of metastasis varies in relation to its linage from the primary tumor. And the sequence goes from the most frequent: lung and breast cancer, melanoma, GU tract, leukemia, GI tract, head and neck tumor. Computed tomography findings are extremely varied and non specific, so there are no radiologic characteristics even from the primary tumor. We reviewed 29 TC studies in the Radiology department of ION-SOLCA, from patients with diagnosis of brain metastasis, our findings showed the great variability in the radio-diagnosis imaging. (The author)

  10. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic

  11. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  12. Computed tomography in subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Lee, Seung Ro; Chang, Kee Hyun; Choi, Byung Ihn; Han, Man Chung; Sim, Bo Sung

    1981-01-01

    Computed Tomography has become increasingly important diagnostic method as the initial examination in the diagnosis of subarachnoid hemorrhage with direct detection of extravasated blood in basal cistern and cortical sulci. Furthermore, CT provides better and exact visualization of the presence, localization, extent and degree of intracerebral, intraventricular and subdural hemorrhage, infarction, hydrocephalus and rebleeding which may be associated with subarachnoid hemorrhage, and also could detect the causative lesions with contrast enhancement in many cases. The purpose of the paper is to describe the CT findings of subarachnoid hemorrhage due to various causes and to evaluate the diagnostic accuracy of CT in subarachnoid hemorrhage. Authors analysed a total of 153 cases with subarachnoid hemorrhage confirmed by lumbar puncture at Seoul National University Hospital from March 1979 to April 1981, with special emphasis on CT findings. All of the cases took CT scan and 125 cases of them angiography. The results are as follows: 1. Most prevalent age group was 4th to 6th decades (78%). The ratio of male to female was 1.1: 1. 2. Of 125 cases with angiography, aneurysm was a major cause (68%). Others were arterio-venous malformation (9.6%), Moya-moya disease (4%) and unknown (18.4%). 3. Of all 153 cases with CT scan, hemorrhage was demonstrated in 98 cases (64.1%); SAH in 72 cases (47.1%), ICH in 65 cases (42.5%), IVH in 34 cases (22.2%) and SDH in 1 case (0.7%). SAH combined with ICH was a major group (34.7%) in SAH. Detection rate of SAH was 68.3% within the first 7 days and 5.8% after 7 dyas. 4. In aneurysms, SAH was detected in 60 of 85 cases (70.6%); 88.1% within the first 7 dyas and 5.6% after 7 dyas. Anterior communicating artery was the most common site of the aneurysms (40%), in which detection rate of SAH was 100% within the first 7 days. SAH was combined with ICH in 38.3%. 5. On CT, SAH of unilateral Sylvian fissure was pathognomonic for ruptured MCA

  13. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  14. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Isherwood, I.; Antoun, N.M.

    1984-01-01

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  15. Motion artifacts in computed tomography

    International Nuclear Information System (INIS)

    Yang, C.K.

    1979-01-01

    In the year 1972, the first Computed Tomography Scanner (or CT) was introduced and caused a revolution in the field of Diagnostic Radiology. A tomogram is a cross-sectional image of a three-dimensional object obtained through non-invasive measurements. The image that is presented is very similar to what would be seen if a thin cross-sectional slice of the patient was examined. In Computed Tomography, x-rays are passed through the body of a patient in many different directions and their attenuation is detected. By using some mathematical theorems, the attenuation information can be converted into the density of the patient along the x-ray path. Combined with modern sophisticated computer signal processing technology, a cross-sectional image can be generated and displayed on a TV monitor. Usually a good CT image relies on the patient not moving during the x-ray scanning. However, for some unconscious or severely ill patients, this is very difficult to achieve. Thus, the motion during the scan causes the so-called motion artifacts which distort the displayed image and sometimes these motion artifacts make diagnosis impossible. Today, to remove or avoid motion artifacts is one of the major efforts in developing new scanner systems. In this thesis, a better understanding of the motion artifacts problem in CT scaning is gained through computer simulations, real scanner experiments and theoretical analyses. The methods by which the distorted image can be improved are simulated also. In particular, it is assumed that perfect knowledge of the patient motion is known since this represents the theoretical limit on how well the distorted image can be improved

  16. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  17. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  18. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  19. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  20. Evolution of Computed Tomography Findings in Secondary Aortoenteric Fistula

    International Nuclear Information System (INIS)

    Bas, Ahmet; Simsek, Osman; Kandemirli, Sedat Giray; Rafiee, Babak; Gulsen, Fatih; Numan, Furuzan

    2015-01-01

    Aortoenteric fistula is a rare but significant clinical entity associated with high morbidity and mortality if remain untreated. Clinical presentation and imaging findings may be subtle and prompt diagnosis can be difficult. Herein, we present a patient who initially presented with abdominal pain and computed tomography showed an aortic aneurysm compressing duodenum without any air bubbles. One month later, the patient presented with gastrointestinal bleeding and computed tomography revealed air bubbles within aneurysm. With a diagnosis of aortoenteric fistula, endovascular aneurysm repair was carried out. This case uniquely presented the computed tomography findings in progression of an aneurysm to an aortoenteric fistula

  1. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  2. Computed tomography of splenic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-12-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children.

  3. Computed tomography of splenic trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.; Laing, F.C.; Federle, M.P.; Goodman, P.C.

    1981-01-01

    Fifty patients with abdominal trauma and possible splenic injury were evaluated by computed tomography (CT). CT correctly diagnosed 21 of 22 surgically proved traumatic sesions of the spleen (96%). Twenty-seven patients had no evidence of splenic injury. This was confirmed at operation in 1 patient and clinical follow-up in 26. There were one false negative and one false positive. In 5 patients (10%), CT demonstrated other clinically significant lesions, including hepatic or renal lacerations in 3 and large retroperitoneal hematomas in 2. In adolescents and adults, CT is an accurate, noninvasive method of rapidly diagnosing splenic trauma and associated injuries. Further experience is needed to assess its usefulness in evaluating splenic injuries in infants and small children

  4. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  5. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  6. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Moon, K.L. Jr.; Federle, M.P.

    1983-01-01

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  7. Computed tomography of cryogenic cells

    International Nuclear Information System (INIS)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-01-01

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions

  8. {sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kanoun, Salim, E-mail: Salim.kanoun@gmail.com [Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon (France); LE2I UMR6306, Centre national de la recherche scientifique, Arts et Métiers, Université Bourgogne Franche-Comté, Dijon (France); MRI Unit, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); Walker, Paul [LE2I UMR6306, Centre national de la recherche scientifique, Arts et Métiers, Université Bourgogne Franche-Comté, Dijon (France); MRI Unit, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); Vrigneaud, Jean-Marc; Depardon, Edouard [Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon (France); Barbier, Vincent [Department of Urology, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); Humbert, Olivier [Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon (France); Moulin, Morgan [Department of Urology, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon (France); and others

    2017-04-01

    Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence. Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.

  9. Radiological protection in computed tomography and cone beam computed tomography.

    Science.gov (United States)

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Minimizing Leg Length Discrepancy After Intramedullary Nailing of Comminuted Femoral Shaft Fractures: A Quality Improvement Initiative Using the Scout Computed Tomography Scanogram.

    Science.gov (United States)

    Gheraibeh, Petra; Vaidya, Rahul; Hudson, Ian; Meehan, Robert; Tonnos, Frederick; Sethi, Anil

    2018-05-01

    To prevent leg length discrepancy (LLD) after locked femoral nailing in patients with comminuted femoral shaft fractures. Prospective consecutive case series aimed at quality improvement. Level 1 Trauma Center PATIENTS:: Ninety-eight consecutive patients with a comminuted femoral shaft fracture underwent statically locked intramedullary nailing, with a focused attempt at minimizing LLD during surgery. A computed tomography scanogram of both legs was performed on postoperative day 1 to assess for residual LLD. Patients were offered the option to have LLD >1.5 cm corrected before discharge. LLD >1.5 cm. Twenty-one patients (21.4%) were found to have an LLD >1.5 cm. An LLD >1.5 cm occurred in 10/55 (18%) antegrade nail patients and 11/43 (26%) retrograde nail patients (P = 0.27). No difference was noted based on the mechanism of injury, surgeon training and OTA/AO type B versus C injury. Ninety of 98 patients left with 1.5 cm after locked intramedullary nailing for a comminuted femoral shaft fracture without being informed and the option of early correction. We recommend using a full-length computed tomography scanogram after IM nailing of comminuted femur fractures to prevent iatrogenic LLD. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  11. Impact of reduced-radiation dual-energy protocols using 320-detector row computed tomography for analyzing urinary calculus components: initial in vitro evaluation.

    Science.gov (United States)

    Cai, Xiangran; Zhou, Qingchun; Yu, Juan; Xian, Zhaohui; Feng, Youzhen; Yang, Wencai; Mo, Xukai

    2014-10-01

    To evaluate the impact of reduced-radiation dual-energy (DE) protocols using 320-detector row computed tomography on the differentiation of urinary calculus components. A total of 58 urinary calculi were placed into the same phantom and underwent DE scanning with 320-detector row computed tomography. Each calculus was scanned 4 times with the DE protocols using 135 kV and 80 kV tube voltage and different tube current combinations, including 100 mA and 570 mA (group A), 50 mA and 290 mA (group B), 30 mA and 170 mA (group C), and 10 mA and 60 mA (group D). The acquisition data of all 4 groups were then analyzed by stone DE analysis software, and the results were compared with x-ray diffraction analysis. Noise, contrast-to-noise ratio, and radiation dose were compared. Calculi were correctly identified in 56 of 58 stones (96.6%) using group A and B protocols. However, only 35 stones (60.3%) and 16 stones (27.6%) were correctly diagnosed using group C and D protocols, respectively. Mean noise increased significantly and mean contrast-to-noise ratio decreased significantly from groups A to D (P calculus component analysis while reducing patient radiation exposure to 1.81 mSv. Further reduction of tube currents may compromise diagnostic accuracy. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. 99mTc-Hexamethyl Propyleneamine Oxime Brain Perfusion Single Photon Emission Computed Tomography in Characterization of Dementia: An Initial Experience in Indian Clinical Practice

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Sinha, Gaurav Kumar; Neogi, Rajarshi; Thukral, Ramesh Kumar

    2014-01-01

    There is a growing health burden in developing countries due to recent trends of increasing incidence of neurodegenerative diseases. To reduce the healthcare cost and effective management of dementia illness, early diagnosis, accurate differentiation and their progression assessment is becoming crucially important. We are utilizing 99m Tc-d, l-hexamethyl propyleneamine oxime (HMPAO) brain perfusion single photon emission computed tomography (SPECT) to characterize dementia on the basis of perfusion patterns and observed significant improvement in their management. Eleven patients (median age of 60 years range of 53-83 years) with clinical suspicion of dementia underwent 99m Tc-HMPAO brain perfusion SPECT. SPECT-computed tomography acquisition done, data are reconstructed, reviewed in three view and further processed in “neurogam” to get voxel based analysis and the comparison with age based normal database and surface mapping. Final diagnosis was done with clinical correlation. Four patients are diagnosed as Alzheimer's disease, two as frontotemporal dementia, one as dementia of Lewy bodies, two as vascular dementia and two as pseudodementia. All imaging findings are well-correlated with clinical background. Brain perfusion SPECT with HMPAO was very helpful to us in characterizing the patients of dementia by its perfusion pattern

  13. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  14. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  15. Computed tomography of obstructive jaundice

    International Nuclear Information System (INIS)

    Suh, Jung Hek; Lee, Joong Suk; Chun, Beung He; Suh, Soo Jhi

    1982-01-01

    It is well known that the computed tomography (CT) is very useful in the evaluation of obstructive jaundice. We have studied 55 cases of obstructive jaundice with whole body scanner from Jun.1980 to Jun. 1981. The results were as follows: 1. The sex distribution was 36 males and 19 females, and 40 cases of obstructive jaundice were seen in fifth, sixth, and seventh decades. 2. Causes of obstructive jaundice were 25 cases of pancreas cancer, 8 cases of common duct cancer, 4 cases of gallbladder cancer, 4 cases of ampulla vater cancer, 12 cases of common duct stone, and 2 cases of common duct stricture. 3. Levels of obstruction were 8 cases of hepatic portion, 15 cases of suprapancreatic portion, 28 cases of pancreatic portion, and 4 cases of ampullary portion. 4. In tumorous condition, CT demonstrated metastasis of other organs, 9 cases of the liver, 1 case of the lung, 3 cases of the pancreas, 3 cases of the common bile duct, 1 case of the stomach, and 12 cases of adjacent lymph nodes. 5. Associated diseases were 12 cases of intrahepatic stone, 4 cases of clonorchiasis, 2 cases of pancreas pseudocyst, 1 cases of hydronephrosis, and 1 case of renal cyst

  16. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  17. X-ray computed tomography

    International Nuclear Information System (INIS)

    Kalender, Willi A

    2006-01-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  18. Computed tomography of epileptic children

    International Nuclear Information System (INIS)

    Kurihara, Mana; Yamashita, Sumimasa; Miyake, Shota; Yamada, Michiko; Iwamoto, Hiroko

    1986-01-01

    The aim of this study was to analyze the changes seen on cranial computed tomography (CT) of epileptic children, especially in the area of the temporal horn. The subjects were 242 epileptic children excluding those with encephalitis, brain tumor, neurocutaneous syndromes, degenerative disease, hydrocephalus etc. The control subjects were 195 children without any neurological disease and symptoms. CT scan were taken with a TCT-60A whole body scanner, and 14 check points were evaluated excluding the temporal horn. 195 epileptic children (N-group) and all control children were normal at 14 check points. Next, the areas of the temporal horns and adjoining hemispheres of the epileptic children (N-group) and control children were examined with Muto-Tablet-Desitizer. The temporal horn ratio ((area of temporal horn/area of ipsilateral hemisphere) x 100) was greater in younger children of the control group, and it was higher in epileptic than in control children. Enlargement of the temporal horn was seen in 1 % of the controls and in 35 % of the 125 epileptic children with normal measurements at 14 points on CT scans (p < 0.01). The frequency of enlargement of temporal horns was not variable among different epileptic types. In the epileptic children with normal CT scans except for enlargement of temporal horns behavioral disturbances were 6 boys and 5 had enlarged temporal horns (bilateral 1 case, left side 1 case, right side 3 cases). (author)

  19. Computed Tomography of Interacerebral Hemorrhage

    International Nuclear Information System (INIS)

    Kim, Seung Hyeon; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Park, Soo Soung

    1983-01-01

    Computed tomography (CT) is the most accurate and reliable method for the diagnosis of intracerebral and intraventricular hemorrhage. The precise anatomic extent of the nematoma, associated cerebral edema, ventricular deformity and displacement, and hydrocephalus are all readily assessed. Aside from head trauma, the principal cause of intracerebral hematoma is hypertensive vascular disease. Although hematomas from various causes may present similar CT appearances frequently the correct etiology may be suggested by consideration of patient's age, clinical history, and the location of the hematoma. The analytical study was performed in 180 cases of intracerebral hemorrhages by CT from October 1981 to January 1983. The results were as follows; 1. The most prevalent age group was 6th decade (37.2%). Male was prevalent to female at the ration of 1.6 to 1. 2. The most common symptom and sign was mental disturbance (48.7%), motor weakness (23%), headache (10.6%), nausea and vomiting (9.8%). 3. The causes of hemorrhage were hypertension (53.9%), head trauma (30.6%), aneurysm (6.1%) and A-V malformation (7.2%). 4. The frequent locations of hemorrhage were basal ganglia and thalamus (40.4%), lobes (35%), ventricles (21.8%). 5. The distribution of hemorrhage was intracerebral hemorrhage (65.6%), intracerebral and intraventricular hemorrhage (30.3%), intraventricular hemorrhage (4.4%).

  20. Recent Developments in Computed Tomography

    International Nuclear Information System (INIS)

    Braunstein, D.; Dafni, E.; Levene, S.; Malamud, G.; Shapiro, O.; Shechter, G.; Zahavi, O.

    1999-01-01

    Computerized Tomography. has become, during the past few years, one of the mostly used apparatus in X-ray diagnosis. Its clinical applications has penetrated to various fields, like operational guidance, cardiac imaging, computer aided surgery etc. The first second-generation CT scanners consisted of a rotate-rotate system detectors array and an X-ray tube. These scanners were capable of acquiring individual single slices, the duration of each being several seconds. The slow scanning rate, and the then poor computers power, limited the application range of these scanners, to relatively stable organs, short body coverage at given resolutions. Further drawbacks of these machines were weak X-ray sources and low efficiency gas detectors. In the late 80's the first helical scanners were introduced by Siemens. Based on a continuous patient couch movement during gantry rotation, much faster scans could be obtained, increasing significantly the volume coverage at a given time. In 1992 the first dual-slice scanners, equipped with high efficiency solid state detectors were introduced by Elscint. The acquisition of data simultaneously from two detector arrays doubled the efficiency of the scan. Faster computers and stronger X-ray sources further improved the performance, allowing for a new range of clinical applications. Yet, the need for even faster machines and bigger volume coverage led to further R and D efforts by the leading CT manufacturers. In order to accomplish the most demanding clinical needs, innovative 2 dimensional 4-rows solid-state detector arrays were developed, together with faster rotating machines and bigger X-ray tubes, all demanding extremely accurate and robust mechanical constructions. Parallel, multi-processor custom computers were made, in order to allow the on-line reconstruction of the growing amounts of raw data. Four-slice helical scanners, rotating at 0.5 sec per cycle are being tested nowadays in several clinics all over the world. This talk

  1. Computed tomography of tuberculous meningitis

    International Nuclear Information System (INIS)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto

    1982-01-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis. (author)

  2. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  3. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  4. Technical aspects of X-ray micro-computed tomography. Initial experience of 27-μm resolution using feldkamp cone-beam reconstruction

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kohara, Kazushi; Iinuma, Gen; Moriyama, Noriyuki

    2007-01-01

    The objective of this study was to introduce the technical utility of micro-computed tomography (CT) with 27-μm resolution by cone-beam CT algorithm. Whole-body micro-CT scans were performed to honeybee. Two- and three-dimensional image analyses were performed by originally developed and available open-source software for acquired images. The original contribution of this work is to describe the technical characteristics of the X-ray micro-CT system, keeping a small experimental insect in a unique condition. Micro-CT may be used as a rapid prototyping tool to research and understand the high-resolution system with Feldkamp cone-beam reconstruction. (author)

  5. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  6. Orbital computed tomography for exophthalmos

    International Nuclear Information System (INIS)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo

    1987-01-01

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos

  7. Computed tomography of cerebrovascular accidents

    International Nuclear Information System (INIS)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin

    1989-01-01

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography

  8. Computed tomography of cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1989-10-15

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography.

  9. Orbital computed tomography for exophthalmos

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan (Korea, Republic of)

    1987-06-15

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos.

  10. Image quality in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Gerke, Oke; Thygesen, Jesper

    2018-01-01

    Background Computed tomography (CT) technology is rapidly evolving and software solution developed to optimize image quality and/or lower radiation dose. Purpose To investigate the influence of adaptive statistical iterative reconstruction (ASIR) at different radiation doses in coronary CT...

  11. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  12. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  13. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  14. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  15. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  16. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  17. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  18. Computed tomography of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Megibow, A.J.; Balthazar, E.J.

    1986-01-01

    New generation CT scans combined with high-detail barium studies have now allowed radiologists to see and gain a more complete understanding of the wall and surrounding structures of the gastrointestinal tract. The editors state that their intent is to ''present in a comprehensive volume an up-to-date evaluation o the role, significance, indications, and limitations of computed tomography of the gastrointestinal tract.'' There is an initial chapter on CT scanning techniques and the use of oral contrast agents. Chapters follow on Ct of the esophagus, stomach, duodenum, small bowel, and colon. The chapters start with a description of the anatomic structures and then cover in detail common pathologic conditions that affect the organ. Indications for examinations are also included in many chapters. There are final chapters on percutaneous drainage of abscesses and fluid collections and on radiologic-patholoic correlation of some of the more common entities

  19. Computed tomography of intraventricular hemorrhage

    International Nuclear Information System (INIS)

    Cho, Bum Shin; Shin, Kyoung Hee; Hahm, Chang Kok

    1982-01-01

    Computed tomography (CT) is a new non-invasive diagnostic imaging method, which has ability to differentiate C.S.F., hematoma, and even edematous brain from normal brain tissue. Prior to the introduction of the CT, the diagnosis of the intraventricular hemorrhage in living patients was difficult and was confirmed by surgery of autopsy. Intracranial hemorrhages are visible on the CT with density higher than brain tissue in acute phase. CT is an accurate method for detecting of intraventricular hemorrhage including detection of nature, location, amount, and associated changes. CT is also useful as a guidance and in the evaluation of fate of the hematomas by easily performable follow up studies. The causes of the intraventricular hemorrhages are hypertension, rupture of aneurysm, arteriovenous malformation, head trauma, brain tumor, and others. This study included evaluation of CT of 69 patients who show the high density in cerebral ventricular system during the period of 31 months from Feb. 1979 to Aug. 1981 in the Department of Radiology, College of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 69 patient was broad ranging from 1 month to 80 years. 28% of patients were in the 6th decade. The mate to female ratio was 2 : 1. 2. The consciousness of patients at CT study: Those were conscious in 11 cases, stuporous in 41 cases and unconscious in 17 cases. 3. The causes of intraventricular hemorrhages were hypertension in 28 cases, head trauma in 12 cases, aneurysm in 4 cases, tumor in 2 cases and others in 23 cases. 4. 9 cases showed intraventricular hematomas only, other 60 cases showed associated intracranial hematomas: Those were intracerebral hematomas in 53 cases including 30 cases of basal ganglial and thalamic hematomas, subarachnoid hemorrhage in 17 cases, epidural hematomas in 3 cases, and subdural hematomas in 2 cases. 5. All cases of the intraventricular hematomas except one sowed hematoma in the lateral

  20. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  1. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  2. Preoperative Computed Tomography-Guided Percutaneous Hookwire Localization of Metallic Marker Clips in the Breast with a Radial Approach: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, T.; Kasami, M.; Uchida, Y.; Sanuki, J.; Kimura, K.; Tanaka, K.; Takahashi, K. [Dept. of Diagnostic Radiology, Dept. of Pathology, and Dept. of Breast Surgery, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka (Japan)

    2007-07-15

    Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  3. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    Science.gov (United States)

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  4. Initial clinical experiences with dopamine D2 receptor imaging by means of 2'-iodospiperone and single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Saji, Hideo; Iwasaki, Yasushi

    1995-01-01

    Dopamine D 2 receptor imaging was performed with 123 I labeled 2'-iodospiperone (2'-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson's disease, 2 with parkinsonism, 1 with Wilson's disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of 123 I-2'-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson's disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson's disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2'-ISP can be used for SPECT imaging of D 2 dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author)

  5. Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

    International Nuclear Information System (INIS)

    Fujita, Takeshi; Tanabe, Masahiro; Yamatogi, Shigenari; Shimizu, Kensaku; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57–93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 ± 13 (SD) min (range 24–78). The average follow-up time interval was 103 days (range 7–812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

  6. Initial clinical experiences with dopamine D{sub 2} receptor imaging by means of 2`-iodospiperone and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yonekura, Yoshiharu [Fukui Medical Schoool, Matsuoka (Japan). Biomedical Imaging Research Center; Saji, Hideo; Iwasaki, Yasushi [and others

    1995-08-01

    Dopamine D{sub 2} receptor imaging was performed with {sup 123}I labeled 2`-iodospiperone (2`-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson`s disease, 2 with parkinsonism, 1 with Wilson`s disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of {sup 123}I-2`-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson`s disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson`s disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2`-ISP can be used for SPECT imaging of D{sub 2} dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author).

  7. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which rotates around the patient. The computer that processes the imaging information and monitor are located in ... follows a spiral path. A special computer program processes this series of pictures, or slices of the ...

  10. Initial experience of using an iron-containing fiducial marker for radiotherapy of prostate cancer: Advantages in the visualization of markers in Computed Tomography and Magnetic Resonance Imaging

    Science.gov (United States)

    Tanaka, Osamu; Iida, Takayoshi; Komeda, Hisao; Tamaki, Masayoshi; Seike, Kensaku; Kato, Daiki; Yokoyama, Takamasa; Hirose, Shigeki; Kawaguchi, Daisuke

    2016-12-01

    Visualization of markers is critical for imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). However, the size of the marker varies according to the imaging technique. While a large-sized marker is more useful for visualization in MRI, it results in artifacts on CT and causes substantial pain on administration. In contrast, a small-sized marker reduces the artifacts on CT but hampers MRI detection. Herein, we report a new ironcontaining marker and compare its utility with that of non-iron-containing markers. Five patients underwent CT/MRI fusion-based intensity-modulated radiotherapy, and the markers were placed by urologists. A Gold Anchor™ (GA; diameter, 0.28 mm; length, 10 mm) was placed using a 22G needle on the right side of the prostate. A VISICOIL™ (VIS; diameter, 0.35 mm; length, 10 mm) was placed using a 19G needle on the left side. MRI was performed using T2*-weighted imaging. Three observers evaluated and scored the visual qualities of the acquired images. The mean score of visualization was almost identical between the GA and VIS in radiography and cone-beam CT (Novalis Tx). The artifacts in planning CT were slightly larger using the GA than using the VIS. The visualization of the marker on MRI using the GA was superior to that using the VIS. In conclusion, the visualization quality of radiography, conebeam CT, and planning CT was roughly equal between the GA and VIS. However, the GA was more strongly visualized than was the VIS on MRI due to iron containing.

  11. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  12. Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.

    Science.gov (United States)

    Lim, Kyungjae; Kwon, Heejin; Cho, Jinhan; Oh, Jongyoung; Yoon, Seongkuk; Kang, Myungjin; Ha, Dongho; Lee, Jinhwa; Kang, Eunju

    2015-01-01

    The purpose of this study was to assess the image quality of a novel advanced iterative reconstruction (IR) method called as "adaptive statistical IR V" (ASIR-V) by comparing the image noise, contrast-to-noise ratio (CNR), and spatial resolution from those of filtered back projection (FBP) and adaptive statistical IR (ASIR) on computed tomography (CT) phantom image. We performed CT scans at 5 different tube currents (50, 70, 100, 150, and 200 mA) using 3 types of CT phantoms. Scanned images were subsequently reconstructed in 7 different scan settings, such as FBP, and 3 levels of ASIR and ASIR-V (30%, 50%, and 70%). The image noise was measured in the first study using body phantom. The CNR was measured in the second study using contrast phantom and the spatial resolutions were measured in the third study using a high-resolution phantom. We compared the image noise, CNR, and spatial resolution among the 7 reconstructed image scan settings to determine whether noise reduction, high CNR, and high spatial resolution could be achieved at ASIR-V. At quantitative analysis of the first and second studies, it showed that the images reconstructed using ASIR-V had reduced image noise and improved CNR compared with those of FBP and ASIR (P ASIR-V had significantly improved spatial resolution than those of FBP and ASIR (P ASIR-V provides a significant reduction in image noise and a significant improvement in CNR as well as spatial resolution. Therefore, this technique has the potential to reduce the radiation dose further without compromising image quality.

  13. Indication for dental computed tomography. Case reports

    International Nuclear Information System (INIS)

    Schom, C.; Engelke, W.; Kopka, L.; Fischer, U.; Grabbe, E.

    1996-01-01

    Based on case reports, common indications for dental computed tomography are demonstrated and typical findings are analysed. From a group of 110 patients who had a reformatted computed tomography of the maxilla and mandibula, 10 typical cases were chosen as examples and are presented with a detailed description of the findings. The most important indication was the analysis of the morphology of the alveolar ridge needed in presurgical planning for osseointegrated implants as well as in special cases of postsurgical control. Apart from implantology, the method could be used in cases of mandibular cysts and bony destructions. In conclusion, dental computed tomography has become established mainly in implantology. It can provide valuable results in cases where a demonstration of the bone in all dimensions and free of overlappings and distortions is needed. (orig.) [de

  14. Computed tomography in malignant primary bone tumours

    International Nuclear Information System (INIS)

    Kersjes, W.; Harder, T.; Haeffner, P.

    1990-01-01

    The importance of computed tomography is examined in malignant primary bone tumours using a strongly defined examination group of 13 Patients (six Ewing's-sarcomas, five osteosarcomas, one chondrosarcoma and one spindle-shaped cell sarcoma). Computed tomography is judged superior compared to plain radiographs in recognition of bone marrow infiltration and presentation of parosteal tumour parts as well as in analysis of tissue components of tumours, CT is especially suitable for therapy planning and evaluating response to therapy. CT does not provide sufficient diagnostic information to determine dignity and exact diagnosis of bone tumours. (orig.) [de

  15. Computed tomography of sacro-iliac joints

    International Nuclear Information System (INIS)

    Miquel, A.; Laredo, J.D.

    1995-01-01

    Actual technologies to explore sacro-iliac joints are conventional radiography, computed tomography , scintigraphy and nuclear magnetic resonance imaging. Standards films are sufficient, except in beginning sacro-iliac septic inflammations where the computed tomography is superior. Two problems are generally posed for the radiologist, to differentiate a septic arthritis from a rheumatic pathology An other problem in diagnosis is to make the difference between a degenerative arthropathy (which does not need a further investigation) and an infectious rheumatic pathology where more exploration is necessary. 28 refs., 3 tabs., 13 figs

  16. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  17. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  18. Physics of x-ray computed tomography

    International Nuclear Information System (INIS)

    Akutagawa, W.M.; Huth, G.C.

    1976-01-01

    Sections are included on theoretical limits of x-ray computed tomography and the relationship of these limits to human organ imaging and specific disease diagnosis; potential of x-ray computed tomography in detection of small calcified particles in early breast cancer detection; early lung cancer measurement and detection; advanced materials for ionizing radiation detection; positron system with circular ring transaxial tomographic camera; contrast mechanism of transmission scanner and algorithms; and status of design on a 200 keV scanning proton microprobe

  19. Computed tomography in dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki

    1990-01-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.)

  20. Metabolic and clinical assessment of efficacy of cryoablation therapy on skeletal masses by 18F-FDG positron emission tomography/computed tomography (PET/CT) and visual analogue scale (VAS): initial experience

    International Nuclear Information System (INIS)

    Masala, Salvatore; Bartolucci, Alberto D.; Mammucari, Matteo; Simonetti, Giovanni; Schillaci, Orazio; Calabria, Ferdinando

    2011-01-01

    Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. 18 F-FDG positron emission tomography/computed tomography ( 18 F-FDG PET/CT) is a single technique of imaging that provides in a ''single step'' both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV max ) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV max value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation. (orig.)

  1. Metabolic and clinical assessment of efficacy of cryoablation therapy on skeletal masses by {sup 18}F-FDG positron emission tomography/computed tomography (PET/CT) and visual analogue scale (VAS): initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Masala, Salvatore; Bartolucci, Alberto D.; Mammucari, Matteo; Simonetti, Giovanni [University Hospital Tor Vergata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy); Schillaci, Orazio; Calabria, Ferdinando [University Hospital Tor Vergata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy); I.R.C.C.S. Neuromed, Department of Nuclear Medicine and Neuroradiology, Pozzilli (Italy); Policlinico Tor Vegata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy)

    2011-02-15

    Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. {sup 18}F-FDG positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) is a single technique of imaging that provides in a ''single step'' both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV{sub max}) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV{sub max} value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation. (orig.)

  2. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  3. Accuracy of Computed Tomography for Predicting Pathologic Nodal Extracapsular Extension in Patients With Head-and-Neck Cancer Undergoing Initial Surgical Resection

    Energy Technology Data Exchange (ETDEWEB)

    Prabhu, Roshan S., E-mail: roshansprabhu@gmail.com [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Magliocca, Kelly R. [Department of Pathology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Hanasoge, Sheela [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Aiken, Ashley H.; Hudgins, Patricia A. [Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Hall, William A. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Chen, Susie A. [Department of Radiation Oncology, University of Texas Southwestern, Dallas, Texas (United States); Eaton, Bree R.; Higgins, Kristin A. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Saba, Nabil F. [Department of Hematology and Medical Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Beitler, Jonathan J. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States)

    2014-01-01

    Purpose: Nodal extracapsular extension (ECE) in patients with head-and-neck cancer increases the loco-regional failure risk and is an indication for adjuvant chemoradiation therapy (CRT). To reduce the risk of requiring trimodality therapy, patients with head-and-neck cancer who are surgical candidates are often treated with definitive CRT when preoperative computed tomographic imaging suggests radiographic ECE. The purpose of this study was to assess the accuracy of preoperative CT imaging for predicting pathologic nodal ECE (pECE). Methods and Materials: The study population consisted of 432 consecutive patients with oral cavity or locally advanced/nonfunctional laryngeal cancer who underwent preoperative CT imaging before initial surgical resection and neck dissection. Specimens with pECE had the extent of ECE graded on a scale from 1 to 4. Results: Radiographic ECE was documented in 46 patients (10.6%), and pECE was observed in 87 (20.1%). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 43.7%, 97.7%, 82.6%, and 87.3%, respectively. The sensitivity of radiographic ECE increased from 18.8% for grade 1 to 2 ECE, to 52.9% for grade 3, and 72.2% for grade 4. Radiographic ECE criteria of adjacent structure invasion was a better predictor than irregular borders/fat stranding for pECE. Conclusions: Radiographic ECE has poor sensitivity, but excellent specificity for pECE in patients who undergo initial surgical resection. PPV and NPV are reasonable for clinical decision making. The performance of preoperative CT imaging increased as pECE grade increased. Patients with resectable head-and-neck cancer with radiographic ECE based on adjacent structure invasion are at high risk for high-grade pECE requiring adjuvant CRT when treated with initial surgery; definitive CRT as an alternative should be considered where appropriate.

  4. Initial multicentre experience of high-speed myocardial perfusion imaging: comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation

    Energy Technology Data Exchange (ETDEWEB)

    Neill, Johanne [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); The Prince Charles Hospital, Brisbane (Australia); Prvulovich, Elizabeth M.; Bomanji, Jamshed B. [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Fish, Matthews B. [Sacred Heart Medical Center (SHMC), Springfield, OR (United States); Berman, Daniel S.; Slomka, Piotr J. [Cedars-Sinai Medical Center, Los Angeles, CA (United States); Sharir, Tali [Procardia Maccabi Healthcare Services (PMHS), Tel Aviv (Israel); Martin, William H. [Vanderbilt University Medical Center (VUMC), Nashville, TN (United States); DiCarli, Marcelo F. [Brigham and Women' s Hospital (BWH), Boston, MA (United States); Ziffer, Jack A. [Baptist Hospital of Miami (BHM), Miami, FL (United States); Shiti, Dalia [Spectrum-Dynamics, Caesarea (Israel); Ben-Haim, Simona [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Chaim Sheba Medical Center, Department of Nuclear Medicine, Tel-Hashomer (Israel)

    2013-07-15

    High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS {>=}3 or coronary territorial SSS {>=}2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5 % and coronary territorial TPD {>=}3 % were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; {>=}50 % was considered significant. Of the 50 patients, 13 (26 %) had no stenosis, 22 (44 %) had single-vessel disease, 6 (12 %) had double-vessel disease and 9 (18 %) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's {rho} 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92 % (35/38), 83 % (10/12) and 90 % (45/50) vs. 84 % (32/38), 50 % (6/12) and 76 % (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89 % (31/35), 57 % (8/14) and 80 % (39/49) vs. 86 % (31/36), 77 % (10/13) and 84 % (41/49), respectively. HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual

  5. Initial Assessment of β3-Adrenoceptor-Activated Brown Adipose Tissue in Streptozotocin-Induced Type 1 Diabetes Rodent Model Using [18F]Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Aparna Baranwal

    2015-12-01

    Full Text Available Metabolic activity of brown adipose tissue (BAT is activated by β3-adrenoceptor agonists and norepinephrine transporter (NET blockers and is measurable using [18F]fluorodeoxyglucose ([18F]FDG positron emission tomography/computed tomography (PET/CT in rats. Using the streptozotocin (STZ-treated rat model of type 1 diabetes mellitus (T1DM, we investigated BAT activity in this rat model under fasting and nonfasting conditions using [18F]FDG PET/CT. Drugs that enhance BAT activity may have a potential for therapeutic development in lowering blood sugar in insulin-resistant diabetes. Rats were rendered diabetic by administration of STZand confirmed by glucose measures. [18F]FDG was injected in the rats (fasted or nonfasted pretreated with either saline or β3-adrenoceptor agonist CL316,243 or the NET blocker atomoxetine for PET/CT scans. [18F]FDG metabolic activity was computed as standard uptake values (SUVs in interscapular brown adipose tissue (IBAT and compared across the different drug treatment conditions. Blood glucose levels > 500 mg/dL were established for the STZ-treated diabetic rats. Under fasting conditions, average uptake of [18F]FDG in the IBAT of STZ-treated diabetic rats was approximately 70% lower compared to that of normal rats. Both CL316,243 and atomoxetine activated IBAT in normal rats had an SUV > 5, whereas activation in STZ-treated rats was significantly lower. The agonist CL316,243 activated IBAT up to threefold compared to saline in the fasted STZ-treated rat. In the nonfasted rat, the IBAT activation was up by twofold by CL316243. Atomoxetine had a greater effect on lowering blood sugar levels compared to CL316,243 in the nonfasted rats. A significant reduction in metabolic activity was observed in the STZ-treated diabetic rodent model. Increased IBAT activity in the STZ-treated diabetic rat under nonfasted conditions using the β3-adrenoceptor agonist CL316,243 suggests a potential role of BAT in modulating blood sugar

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... so that the x-ray beam follows a spiral path. A special computer program processes this series ... Sometimes ultrasound is substituted for CT as a method of imaging in these procedures in children. A ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... planes, and can even generate three-dimensional images. These images can be viewed on a computer monitor, ... diabetes, kidney disease or thyroid problems. Any of these conditions may influence the decision on whether contrast ...

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  11. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  12. Computed Tomography Study Of Complicated Bacterial Meningitis ...

    African Journals Online (AJOL)

    To monitor the structural intracranial complications of bacterial meningitis using computed tomography (CT) scan. Retrospective study of medical and radiological records of patients who underwent CT scan over a 4 year period. AUniversityTeachingHospital in a developing country. Thirty three patients with clinically and ...

  13. Computed tomography - old ideas and new technology

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik; Boas, F.E. [Stanford University, School of Medicine, Department of Radiology, Stanford, CA (United States)

    2011-03-15

    Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

  14. Computed tomography in the evaluation of trauma

    International Nuclear Information System (INIS)

    Federle, M.P.; Brant-Zawadzki, M.

    1982-01-01

    This book is intended to be the current standard for computed tomography in the evaluation of trauma. It summarizes two years of experience at San Francisco General Hospital. The book is organized into seven chapters, covering head, maxillofacial, laryngeal, spinal, chest, abdominal, acetabular, and pelvic trauma. Extremity trauma is not discussed

  15. Computed tomography (CT) and diastematomyelia's diagnosis

    International Nuclear Information System (INIS)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S.; Barros, A.P. de

    1982-01-01

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized. (Author) [pt

  16. Computed tomography evaluation of petrous bone fractures ...

    African Journals Online (AJOL)

    Background: Petrous bone trauma is the sequel of blunt head injury and can have life threatening complications resulting in immediate mortality. Early detection and good knowledge of the Computed Tomography (CT) findings ensure prompt treatment of both fractures and complications. Objective: To document the ...

  17. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  18. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  19. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  20. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  1. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...

  2. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...

  3. Investigation of measuring strategies in computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2011-01-01

    Computed tomography has entered the industrial world in 1980’s as a technique for non-destructive testing and has nowadays become a revolutionary tool for dimensional metrology, suitable for actual/nominal comparison and verification of geometrical and dimensional tolerances. This paper evaluates...

  4. Computed tomography in severe protein energy malnutrition.

    OpenAIRE

    Househam, K C; de Villiers, J F

    1987-01-01

    Computed tomography of the brain was performed on eight children aged 1 to 4 years with severe protein energy malnutrition. Clinical features typical of kwashiorkor were present in all the children studied. Severe cerebral atrophy or brain shrinkage according to standard radiological criteria was present in every case. The findings of this study suggest considerable cerebral insult associated with severe protein energy malnutrition.

  5. Computed tomography of the iliopsoas muscle

    International Nuclear Information System (INIS)

    Nino-Murcia, M.; Wechsler, R.J.; Brennan, R.E.

    1983-01-01

    Computed tomography (CT) is an ideal method for the imaging of the psoas muscle. The authors present 13 cases of patients with psoas abnormalities diagnosed by CT. The CT features of the different pathologic entities and comparison of CT with other imaging modalities are discussed. (orig.)

  6. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal

  7. Misty mesentery: computed tomography findings

    International Nuclear Information System (INIS)

    Ahualli, Jorge; Mendez Uriburu, Luis; Ravera, Maria L.; Cikman, Pablo

    2008-01-01

    An alteration in the density of the mesenteric adipose tissue is often the principal clue of underlying mesenteric and bowel disease. The term 'Misty Mesentery' describes the computed tomographic appearance of mesenteric fat infiltrated by inflammatory cells, fluid (edema, lymph, and/or blood), tumor, and fibrosis. (author) [es

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, so that the x-ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the body, to ...

  10. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    was not used. Autopsies were performed according to the Danish government's official guidelines. PMCT and autopsy findings were interpreted independent of each other. Diagnoses, including the cause of death and histology findings, were registered in a computer database (SPSS) together with information about...

  11. Computed tomography in Alexander's disease

    Energy Technology Data Exchange (ETDEWEB)

    Holland, I M; Kendall, B E

    1980-10-01

    Two cases of biopsy-proven Alexander's disease are described with computed tomographic changes which, in our experience and on survey of the literature, have not occurred in any other condition. Such changes in a child with a progressive condition consistent with Alexander's disease, strongly support the diagnosis.

  12. Computed tomography of limy bile

    International Nuclear Information System (INIS)

    Yamamoto, Shinichiro; Kimoto, Masatoshi; Gunge, Nobuharu; Sano, Kaizo; Yamashita, Sachiko; Hirano, Yutaka

    1983-01-01

    The computed tomographic appearance of three cases of limy bile was reported. The CT findings consist of uniform high density within gallbladder, niveau formation between limy bile and noncalcified bile. Sagittal reconstruction of CT images was especially useful in the differentiation of limy bile and gallstones. (author)

  13. Prospective study of tailoring whole-body dual-modality [18F]fluorodeoxyglucose positron emission tomography/computed tomography with plasma Epstein-Barr virus DNA for detecting distant metastasis in endemic nasopharyngeal carcinoma at initial staging.

    Science.gov (United States)

    Tang, Lin-Quan; Chen, Qiu-Yan; Fan, Wei; Liu, Huai; Zhang, Lu; Guo, Ling; Luo, Dong-Hua; Huang, Pei-Yu; Zhang, Xu; Lin, Xiao-Ping; Mo, Yun-Xian; Liu, Li-Zhi; Mo, Hao-Yuan; Li, Jian; Zou, Ru-Hai; Cao, Yun; Xiang, Yan-Qun; Qiu, Fang; Sun, Rui; Chen, Ming-Yuan; Hua, Yi-Jun; Lv, Xing; Wang, Lin; Zhao, Chong; Guo, Xiang; Cao, Ka-Jia; Qian, Chao-Nan; Zeng, Mu-Sheng; Mai, Hai-Qiang

    2013-08-10

    To evaluate which patients with nasopharyngeal carcinoma (NPC) obtained the greatest benefits from the detection of distant metastasis with [(18)F]fluorodeoxyglucose positron emission tomography and computed tomography (PET/CT) combined with plasma Epstein-Barr virus (EBV) DNA levels. Consecutive patients with NPC were prospectively enrolled. PET/CT, conventional work-up (CWU), and quantification of plasma EBV DNA were performed before treatment. The accuracy of these strategies for distant metastases was assessed. The costs of the diagnostic strategies were compared. Eighty-six (14.8%) of the 583 eligible patients were found to have distant metastases; 71 patients (82.6%) by PET/CT and 31 patients (36.0%) by CWU. In the multivariable analysis, advanced N stage (odds ratio, 2.689; 95% CI, 1.894 to 3.818) and pretreatment EBV DNA level (odds ratio, 3.344; 95% CI, 1.825 to 6.126) were significant risk factors for distant metastases. PET/CT was not superior to CWU for detecting distant metastases in very low-risk patients (N0-1 with EBV DNA < 4,000 copies/mL; P = .062), but was superior for the low-risk patients (N0-1 with EBV DNA ≥ 4,000 copies/mL and N2-3 with EBV DNA < 4,000 copies/mL; P = .039) and intermediate-risk patients (N2-3 disease with EBV DNA ≥ 4,000 copies/mL; P < .001). The corresponding patient management changes based on PET/CT were 2.9%, 6.3%, and 16.5%, respectively. The costs per true-positive case detected by PET/CT among these groups were ¥324,138 (≈$47,458), ¥96,907 (≈$14,188), and ¥34,182 (≈$5,005), respectively. PET/CT detects more distant metastases than conventional staging in patients with NPC. The largest benefit in terms of cost and patient management was observed in the subgroup with N2-3 disease and EBV DNA ≥ 4,000 copies/mL.

  14. Thermoluminescent dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Lara C, A.; Rivera M, T.; Osorio V, M.; Hernandez O, O.

    2016-10-01

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  15. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  16. Cerebral candidiasis. Computed tomography appearance

    International Nuclear Information System (INIS)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-01-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.)

  17. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  18. Microfocus computed tomography in medicine

    Science.gov (United States)

    Obodovskiy, A. V.

    2018-02-01

    Recent advances in the field of high-frequency power schemes for X-ray devices allow the creation of high-resolution instruments. At the department of electronic devices and Equipment of the St. Petersburg State Electrotechnical University, a model of a microfocus computer tomograph was developed. Used equipment allows to receive projection data with an increase up to 100 times. A distinctive feature of the device is the possibility of implementing various schemes for obtaining projection data.

  19. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  20. Computed tomography of thymic abnormalities

    International Nuclear Information System (INIS)

    Schnyder, P.; Candardjis, G.

    1987-01-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis. (orig.)

  1. Orbital computed tomography: technical aspects

    International Nuclear Information System (INIS)

    Beck, T.J.; Rosenbaum, A.E.; Miller, N.R.

    1982-01-01

    Computed tomographic scanning has revolutionized the diagnosis and management of orbital disease. The best use of this methodology requires knowledge of the principles and appropriate attention to scanning protocols. Computed tomographic scanning of the orbit is a demanding technique requiring thin sections through planes precisely positioned from the topographical anatomy. Ideally, orbital CT should include both transverse axial and coronal sections: The pathological condition and its plane of growth will influence the selection of the optimal plane or section. Coronal sections may be obtained either directly or indirectly by computer reconstruction from contiguous transverse images. Sagittal or oblique sections or both also are useful and may be obtained directly or indirectly. Difficulty in patient positioning may preclude direct sagittal imaging, however. The use of intravenous contrast enhancement is not necessary as a routine technique unless a mass is identified or suspected. Where surgical resection or biopsy of a space-occupying lesion is contemplated, contrast enhancement can be valuable in assessing relative vascularity and aiding diagnostic specificity. It should be continually emphasized that CT is a powerful technology which, in orbital diagnosis, produces the highest yield when clinician and radiologist collaborate in the radiodiagnostic workup. The clinical information supplied by the referring ophthalmologist is used by the radiologist both in the selection of the appropriate techniques for investigation and in striving to achieve the most specific conclusion

  2. Proton computed tomography images with algebraic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzi, M. [Physics and Astronomy Department, University of Florence, Florence (Italy); Civinini, C.; Scaringella, M. [INFN - Florence Division, Florence (Italy); Bonanno, D. [INFN - Catania Division, Catania (Italy); Brianzi, M. [INFN - Florence Division, Florence (Italy); Carpinelli, M. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Cirrone, G.A.P.; Cuttone, G. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Presti, D. Lo [INFN - Catania Division, Catania (Italy); Physics and Astronomy Department, University of Catania, Catania (Italy); Maccioni, G. [INFN – Cagliari Division, Cagliari (Italy); Pallotta, S. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Randazzo, N. [INFN - Catania Division, Catania (Italy); Romano, F. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Sipala, V. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Chemistry and Pharmacy Department, University of Sassari, Sassari (Italy); Talamonti, C. [INFN - Florence Division, Florence (Italy); Department of Biomedical, Experimental and Clinical Sciences, University of Florence, Florence (Italy); SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze (Italy); Vanzi, E. [Fisica Sanitaria, Azienda Ospedaliero-Universitaria Senese, Siena (Italy)

    2017-02-11

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to ~1% and spatial resolutions <1 mm, achieved within processing times of ~15′ for a 512×512 pixels image prove that this technique will be beneficial if used instead of X-CT in hadron-therapy.

  3. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  4. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  5. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  6. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  7. Computed tomography of the menisci

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.; Rupp, N.; Paar, O.; Rodammer, G.

    1988-01-01

    Thirty patients were examined with CT of the menisci. All findings were confirmed by arthroscopy. One false positive diagnosis of a torn meniscus was made, caused by partial volume effect. In seven patients with irregular degenerative changes of the menisci, the abnormality could be clearly demonstrated. One meniscus ganglion was shown. Seven meniscus lesions, which were not shown by arthrography or arthroscopy, were clearly demonstrated by CT. The computer tomographic demonstration of menisci can replace knee arthrography as the examination of choice and should be performed before carrying out arthroscopy. (orig.) [de

  8. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  9. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  10. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... applications. This thesis takes a systematic approach toward establishing quantitative understanding of conditions for sparse reconstruction to work well in CT. A general framework for analyzing sparse reconstruction methods in CT is introduced and two sets of computational tools are proposed: 1...... contributions to a general set of computational characterization tools. Thus, the thesis contributions help advance sparse reconstruction methods toward routine use in...

  11. Computed tomography of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kimoto, Makoto; Hashimoto, Keiji; Hiraki, Yoshio

    1984-12-01

    Plain x-ray and computed tomographic (CT) findings were compared in 7 patients with pelvic fractures (2 males and 5 females) aged between 35 and 50 year. Plain x-rays had a higher sensitivity than CT in detecting fractures of the ischiatic and pubic ramuses, and deviation of bone fragments. CT was superior to plain x-rays near the acetabulum and in detecting deviation of bone fragments. Although there were no differences between the two modalities in detecting fractures of the wing of ilium, CT was more useful than plain x-rays in visualizing deviation of bone fragments. CT clearly visualized not only fractures but also injuries of the soft tissues, such as pelvic viscera and muscles, and the presence of hematoma. CT seems to be a useful method for observing the condition and process of pelvic injuries and for deciding treatment protocols.

  12. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  13. Computed tomography evaluation of autogenous graft in sinus lift surgery

    International Nuclear Information System (INIS)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro; Alves, Maria Teresa de Seixas

    2001-01-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  14. Single photon emission computed tomography and oth selected computer topics

    International Nuclear Information System (INIS)

    Frey, G.D.

    1981-01-01

    This book, the proceedings of a meeting in January 1980, contains 21 papers. Thirteen are devoted to aspects of emission tomography, four to nuclear cardiology, and five to other topics. The initial set of papers consists of reviews of the single photon emission tomography process. These include transverse axial tomography using scintillation cameras and other devices, longitudinal section tomography, and pin-hole and slant-hole systems. These reviews are generally well done, but as might be expected, lack any coherence from paper to paper. The papers on nuclear cardiology include several of Fourier analysis in nuclear cardiology and one on shunt quantification. Other clinical papers are on quantifying Tc-99m glucoheptonate uptake in the brain and on iron-59 retention studies. A general criticism of the book is the poor quality of photographic reproductions

  15. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Galanski, M.; Prokop, M.; Joergensen, M.; Koehler, A.; Leppert, A.; Lehmann, K.J.; Schaefer-Prokop, C.; Smekal, U. v.

    1998-01-01

    The textbook covers all aspects of the modern (spiral) CT methods: The technical principle, evaluation modalities and artefacts, specific diagnostic examinations such as CT angiography, CTAP, CT arthrography, CT-guided biopsy, as well as the principles guiding the analysis of the tomographic images are explained in the initial chapter on fundamentals. Further methodological information is given in the second chapter discussing the various examination strategies, and the value of the material is enhanced by a wealth of diagnostic image reproductions of latest available standard. The chapters devoted to the body organs of interest are arranged by organs and cover information on the normal anatomy, diagnostic examination techniques, contrast agent performance and, as a very important part, the full-detail CT morphology, supplemented by information describing the anatomy, pathophysiology and clinical aspects of relevance to the diagnostic decisions. There are as well many practical hints which readers may find useful in their practical work. Every chapter contains tables summarizing and showing at a glance information on indications, specific examination techniques, including the scan parameters for the spiral CT, and on differential diagnoses. (orig./CB) [de

  16. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  17. Cone beam computed tomography in endodontic

    International Nuclear Information System (INIS)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  18. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  19. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  20. Soil structure changes evaluated with computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz Fernando

    2010-01-01

    The objective of this work was to evaluate in millimetric scale changes in soil bulk density and porosity, using the gamma-ray computed tomography in soil samples with disturbed structure due to wetting and drying (W-D) cycles. Soil samples with 98.1 cm 3 were sieved using a 2 mm mesh and homogeneously packed in PVC cylinders. Soil samples were submitted to 1, 2, and 3 W-D cycles. Control samples were not submitted to W-D cycles. After repetitions of W-D cycles, soil sample porosity decreased and soil layers became denser. Computed tomography allowed a continuous analysis of soil bulk density and also soil porosity along millimetric (0.08 cm) layers, what cannot be provided by traditional methods used in soil physics. (author)

  1. Possibilities of computer tomography in multiple sclerosis

    International Nuclear Information System (INIS)

    Vymazal, J.; Bauer, J.

    1983-01-01

    Computer tomography was performed in 41 patients with multiple sclerosis, the average age of patients being 40.8 years. Native examinations were made of 17 patients, examinations with contrast medium of 19, both methods were used in the examination of 5 patients. In 26 patients, i.e. in almost two-thirds, cerebral atrophy was found, in 11 of a severe type. In 9 patients atrophy affected only the hemispheres, in 16 also the stem and cerebellum. The stem and cerebellum only were affected in 1 patient. Hypodense foci were found in 21 patients, i.e. more than half of those examined. In 9 there were multiple foci. In most of the 19 examined patients the hypodense changes were in the hemispheres and only in 2 in the cerebellum and brain stem. No hyperdense changes were detected. The value and possibilities are discussed of examinations by computer tomography multiple sclerosis. (author)

  2. Basic principle of cone beam computed tomography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan

    2006-01-01

    The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography(CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems

  3. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  4. Xenon as an adjunct in computed tomography

    International Nuclear Information System (INIS)

    Kendall, B.E.; Radue, E.W.; Zilkha, E.; Loh, L.

    1979-01-01

    Nonradioactive xenon was used for enhancement in computed tomography in a series of 18 patients requiring general anesthesia. The method and results are described. The properties of xenon are radically different from those of intravenous iodides, and the enhancement patterns demonstrate different aspects of both normal and abnormal tissues. In our limited experience, it has been of value in those isodense and low attenuation lesions that have not enhanced after intravenous Conray. (orig.) 891 MG/orig. 892 MB [de

  5. Computed tomography of the eye and orbit

    International Nuclear Information System (INIS)

    Hammerschlag, S.B.; Hesselink, J.R.; Weber, A.L.

    1982-01-01

    This book is the product of the evolution of computed tomography (CT) into subspecialization and the need for one source of information for the busy radiologist. The authors have succeeded in providing a readable overview of orbital CT as well as a reference book. The book is divided into seven major catagories of pathology (Neurofibromatosis, Primary Orbital Neoplasms, Secondary and Metastic Tumors of the Orbit, Vascular Disorders, Inflammatory Disease, Occular Lesions, and Trauma) after separate discussions of anatomy and technique

  6. Computed tomography in gastrointestinal stromal tumors

    International Nuclear Information System (INIS)

    Ghanem, Nadir; Altehoefer, Carsten; Winterer, Jan; Schaefer, Oliver; Springer, Oliver; Kotter, Elmar; Langer, Mathias; Furtwaengler, Alex

    2003-01-01

    The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary (n=20) and (n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST ( 5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly

  7. Computed tomography in opportunistic lung infections

    International Nuclear Information System (INIS)

    Hartelius, H.

    1988-01-01

    Chest radiography in two teenage boys, one with Wiscott-Aldrich's syndrome and one with acute lymphatic leucemia in remission showed increased interstitial pattern. In both computed tomography (CT) of the lungs showed heavy interstitial pneumonia, rather different in appearance but in both cases equal to the CT findings in opportunistic lung infections known from immunoincompetent patients with for instance pneumocystis carinii and/or cytomegalo virus infections. In both patients the CT findings led to lung biopsy establishing the etiologic agent. (orig.)

  8. Cranial computed tomography of the neurofibromatosis

    International Nuclear Information System (INIS)

    Fukuda, Teruo; Inoue, Yuichi; Shibakiri, Ippei

    1981-01-01

    The computed tomography (CT) was performed in 10 cases of neurofibromatosis. The CT scan showed the abnormal findings in 8 cases out of 10. Skull lesions were noted in 3 cases and intracranial tumors were found in 5 among which multiple neoplasms were seen in 3. Although reported cases were not large enough in number, the incidence and variety of the tumors were similar to others reported before CT era. (author)

  9. Computed tomography manifestations of peritoneal diseases

    International Nuclear Information System (INIS)

    Gordon, K.; Lee, W.K.; Hennessy, O.

    2005-01-01

    The peritoneal cavity is a potential space that is divided by the peritoneal reflections into various complex subspaces. It can be involved in many disease processes including developmental, inflammatory, neoplastic and traumatic conditions. Computed tomography is highly sensitive and consistent in detecting peritoneal pathology. This pictorial essay aims to emphasize and illustrate the CT features of the spectrum of peritoneal diseases. Copyright (2005) Blackwell Science Pty Ltd

  10. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  11. Computed tomography after radical pancreaticoduodenectomy (Whipple's procedure)

    International Nuclear Information System (INIS)

    Smith, S.L.; Hampson, F.; Duxbury, M.; Rae, D.M.; Sinclair, M.T.

    2008-01-01

    Whipple's procedure (radical pancreaticoduodenectomy) is currently the only curative option for patients with periampullary malignancy. The surgery is highly complex and involves multiple anastomoses. Complications are common and can lead to significant postoperative morbidity. Early detection and treatment of complications is vital, and high-quality multidetector computed tomography (MDCT) is currently the best method of investigation. This review outlines the surgical technique and illustrates the range of normal postoperative appearances together with the common complications

  12. Fatty kidney diagnosed by mortem computed tomography

    DEFF Research Database (Denmark)

    Leth, P. M.

    2016-01-01

    Subnuclear vacuolization of the renal tubular epithelium is indicative of diabetic and alcoholic ketoacidosis and has also been proposed as a postmortem marker for hypothermia. We present for the first time a fatal case of ketoacidosis in combination with exposure where a suspicion of these diagn...... of these diagnoses was raised by a marked radiolucency of the kidneys at post-mortem computed tomography (PMCT). © 2015 Elsevier Ltd....

  13. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  14. Computed tomography in intracranial malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, S; Odake, G; Fujimoto, M; Yamaki, T; Mizukawa, N [Kyoto Prefectural Univ. of Medicine (Japan)

    1978-09-01

    Malignant lymphoma of the central nervous system has been found more and more often in recent years, partly because of the increased use of radiation and such drugs as steroids and antibiotics. However, the definite diagnosis of this disease is difficult until histological verification has been done by operation or autopsy. Since the revolutionary development of computed tomography, however, several reports have been presented, on the computed tomography of malignant lymphoma of the thorax and abdomen. Nevertheless, only a few cases of intracranial malignant lymphoma have been reported. The purpose of this paper, using four patients, is to emphasize the value of computed tomography in the diagnosis of intracranial malignant lymphoma. The characteristic CT findings of intracranial malignant lymphoma may be summarized follows: (1) the tumors are demonstrated to be well-defined, nodular-shaped, and homogenous isodensity - or slightly high-density - lesions in plain scans, and the tumors homogenously increase in density upon contrast enhancement; (2) the disease always has multifocal intracranial lesions, which are shown simultaneously or one after another, and (3) perifocal edema is prominent around the tumors in the cerebral hemisphere.

  15. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  16. Basic principles of cone beam computed tomography.

    Science.gov (United States)

    Abramovitch, Kenneth; Rice, Dwight D

    2014-07-01

    At the end of the millennium, cone-beam computed tomography (CBCT) heralded a new dental technology for the next century. Owing to the dramatic and positive impact of CBCT on implant dentistry and orthognathic/orthodontic patient care, additional applications for this technology soon evolved. New software programs were developed to improve the applicability of, and access to, CBCT for dental patients. Improved, rapid, and cost-effective computer technology, combined with the ability of software engineers to develop multiple dental imaging applications for CBCT with broad diagnostic capability, have played a large part in the rapid incorporation of CBCT technology into dentistry. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  18. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  19. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  20. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  1. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  2. Role of Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Diagnostic Evaluation of Carcinoma Urinary Bladder: Comparison with Computed Tomography

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Kashyap, Raghava; Mete, Utham Kumar; Narang, Vikram; Das, Ashim; Bhattacharya, Anish; Khandelwal, Niranjan; Mandal, Arup K.

    2014-01-01

    Bladder carcinoma is the most frequent tumor of the urinary tract and accounts 7% of all malignancies in men and 2% of all malignancies in women. This retrospective study was carried out to assess the diagnostic utility of F18-fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the imaging evaluation of bladder carcinoma. Seventy-seven consecutive patients diagnosed to have carcinoma urinary bladder referred for F18-FDG PET/CT were included in this study. Thirty-four patients were for initial staging after transurethral biopsy and remaining 43 patients were for restaging. All patients also underwent CT scan of the abdomen and pelvis. PET/CT findings were correlated with diagnostic CT scan and histopathological findings. In 30 of the 34 patients for initial staging, both PET/CT and CT confirmed the primary lesion in the bladder. Histopathology report was available in 23 patients. Lymph nodes FDG uptake reported to be metastatic in 10/23 patients while CT detected lymph node metastasis in 12 patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy have been calculated to be 87.5%, 80%, 70%, 92%, 82% for PET/CT and 66%, 57%, 50%, 72%, 60% for CT respectively. PET/CT detected metastatic disease in 8 patients whereas CT detected in 4 patients. Of the 43 patients for restaging, local recurrence was detected in 24 patients on both PET/CT and CT. Histopathology report was available in 17 patients. Sensitivity, specificity, PPV, NPV and accuracy were 85%, 60%, 60%, 85%, 70% for PET/CT and 80%, 50%, 40%, 85%, 58% for CT respectively. Nineteen patients were detected to have metastatic disease by PET/CT, whereas CT detected metastases in 11 patients. F-18 FDG PET/CT is a very useful modality in pre-operative staging and monitoring after surgery, chemotherapy or radiotherapy of patients with carcinoma urinary bladder

  3. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  4. Cranial computed tomography in maple syrup urine disease

    International Nuclear Information System (INIS)

    Irnberger, T.; Ploechl, E.; Rittinger, O.; Bachmann, C.; Pilz, P.; Walter, G.F.; Wendel, U.; Landeskrankenanstalten Salzburg; Bern Univ.; Landesnervenklinik Salzburg; Graz Univ.; Dudley Observatory, Albany, NY; Duesseldorf Univ.

    1986-01-01

    Cranial computed tomography in the initial stage of the intermediate phenotype of maple syrup urine disease (MSUD) demonstrates diffuse, symmetric hypodensities in white and grey matter, which show a complete return to normal after early introduction of an adequate protein-restrictive diet. If diagnosis of this disease is missed or delayed, progressive global (end-stage) atrophy will take place over several years. A decrease in density values correlates well with the total cerebral lipid and water content (closely related to myelinisation), whereas progression and grade of atrophy show a relationship with the severity of pathological white and grey matter changes that are not demonstrable with computed tomography but can be proven histologically. Analysis of both morphological parameters corresponds well with clinical-neurological outcome and therapeutic success. (orig.) [de

  5. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  6. Positron computed tomography: current state, clinical results and future trends

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  7. Positron computed tomography: current state, clinical results and future trends

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1980-01-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends

  8. Total variation-based neutron computed tomography

    Science.gov (United States)

    Barnard, Richard C.; Bilheux, Hassina; Toops, Todd; Nafziger, Eric; Finney, Charles; Splitter, Derek; Archibald, Rick

    2018-05-01

    We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. In order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. The algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

  9. Cross-sectional anatomy for computed tomography

    International Nuclear Information System (INIS)

    Farkas, M.L.

    1988-01-01

    This self-study guide recognizes that evaluation and interpretation of CT-images demands a firm understanding of both cross-sectional anatomy and the principles of computed tomography. The objectives of this book are: to discuss the basic principles of CT, to stress the importance of cross-sectional anatomy to CT through study of selected cardinal transverse sections of head, neck, and trunk, to explain orientation and interpretation of CT-images with the aid of corresponding cross-sectional preparations

  10. Computed tomography scans of metastatic hepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Fukuda, Haruyuki; Nemoto, Yutaka [Osaka City Univ. (Japan). Faculty of Medicine

    1984-01-01

    Computed tomography scans of 114 metastatic hepatic tumors were reviewed. Central low density was found in 82 cases (71.9%) and seems to be characteristic to metastatic hepatic tumors. Dynamic CT was performed on 34 cases, and 21 (61.8%) of these had ring enhancement at the arterial phase. Most of metastatic hepatic tumors could be differentiated from hepatocellular carcinoma. However, metastatic hepatic tumors from renal cell carcinoma, renal rhabdomyosarcoma, malignant melanoma and leiomyosarcoma could not be differentiated from hepatocellular carcinoma, even with use of dynamic study.

  11. Computed tomography appearances of sclerosing encapsulating peritonitis

    International Nuclear Information System (INIS)

    George, C.; Al-Zwae, K.; Nair, S.; Cast, J.E.I.

    2007-01-01

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP

  12. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  13. Application of protons to computer tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.; Bradbury, J.N.; Cannon, T.M.; Hutson, R.L.; Laubacher, D.B.; Macek, R.; Paciotti, M.A.; Taylor, C.A.

    1977-01-01

    It was demonstrated that the application of protons to computed tomography can result in a significant dose advantage relative to x rays. Thus, at the same dose as is delivered by contemporary commercial x-ray scanners, a proton scanner could produce reconstructions with a factor of 2 or more improvement in density resolution. Whether such an improvement can result in significantly better diagnoses of human disease is an open question which can only be answered by the implementation of a proton scanner in a clinical situation

  14. Contrast media on abdominal computed tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.; Oestensen, H.M.

    1984-01-01

    Abdominal computed tomography was performed in 55 patients before and after intravenous injection of 60 ml of a non-ionic (iohexol) or an ionic (metrizoate) contrast medium. The adverse effects were recorded and a series of measurements of attenuation values before and after the contrast medium injection was performed in the aorta and in hepatic and renal parenchyma. Only minor adverse effects were seen with both contrast media, but iohexol was clearly better tolerated than metrizoate. No difference in the enhancement properties was found between the two contrast media. (orig.)

  15. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  16. Computed tomography of the spine: Diagnostic exercises

    International Nuclear Information System (INIS)

    Kricun, R.; Kricun, M.E.

    1987-01-01

    The authors' aim is to provide diagnostic challenges and information to improve the readers' ability to interpret computed tomography (CT) scans of the spine. The entire vertebral column and adjacent soft-tissue structures are covered. The authors discuss normal findings, and congenital, traumatic, inflammatory, neoplastic, degenerative, idiopathic, and postoperative findings. Sixty-six case examples are presented, followed by description of the findings. Additional examples are given, and drawings and photographs of specimens are used to illustrate and clarify the pathologic conditions. Other modalities, including their advantages and disadvantages, are illustrated and discussed where appropriate. The relative merits of these modalities are presented

  17. Computed tomography features of small bowel volvulus

    International Nuclear Information System (INIS)

    Loh, Y.H.; Dunn, G.D.

    2000-01-01

    Small bowel volvulus is a cause of acute abdomen and commonly occurs in neonates and young infants. Although it is rare in adults in the Western world,' it is a relatively common surgical emergency in the Middle East, India and Central Africa. It is associated with a mortality rate of 10-67% and, hence, it is important to make an early diagnosis to expedite surgical intervention. Computed tomography has become an important imaging modality in diagnosis and a number of signs have been recognized in a handful of documented case reports. We describe a case of small bowel volvulus that illustrates these important CT signs. Copyright (1999) Blackwell Science Pty Ltd

  18. Computed tomography in neuronal ceroid lipofuscinosis

    International Nuclear Information System (INIS)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neutronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter. (orig.) [de

  19. Unusual causes of obstructive jaundice. Computed tomography

    International Nuclear Information System (INIS)

    Rodriguez, E.; Pombo, F.; Cao, I.; Fernandez, R.; Riba da, M.

    1998-01-01

    The purpose of this study is to present selected computed tomography (CT) images showing unusual causes of obstructive jaundice. We reviewed retrospectively the Ct findings of obstructive jaundice in 227 patients. The most common causes of biliary obstruction were adenocarcinoma of the pancreatic head (n=77) and cholangiocarcinoma (n=65). In 13 cases (5.7%), the etiology of obstructive jaundice was unusual or exceptional: tuberculous adenitis (n=3), obstruction of afferent loop (n=2)signet ring cell adenocarcinoma (n=3); in duodenum, gallbladder and papilla of Water), Mirizzi syndrome (n=1), adenocarcinoma of the hepatic flexure (n=1), choledochal cyst (n=1) and pancreatic lymphoma (n=1). (Author) 13 refs

  20. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  1. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  2. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  3. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  4. Speeding up image reconstruction in computed tomography

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    Computed tomography (CT) is a technique for imaging cross-sections of an object using X-ray measurements taken from different angles. In last decades a significant progress has happened there: today advanced algorithms allow fast image reconstruction and obtaining high-quality images even with missing or dirty data, modern detectors provide high resolution without increasing radiation dose, and high-performance multi-core computing devices are there to help us solving such tasks even faster. I will start with CT basics, then briefly present existing classes of reconstruction algorithms and their differences. After that I will proceed to employing distinctive architectural features of modern multi-core devices (CPUs and GPUs) and popular program interfaces (OpenMP, MPI, CUDA, OpenCL) for developing effective parallel realizations of image reconstruction algorithms. Decreasing full reconstruction time from long hours up to minutes or even seconds has a revolutionary impact in diagnostic medicine and industria...

  5. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  6. Computed tomography of juvenile nasopharyngeal angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yoo, Shi Joon; Lee, Yul; Chang, Kee Hyun; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma.

  7. Evaluation of valvular heart diseases with computed tomography

    International Nuclear Information System (INIS)

    Tomoda, Haruo; Hoshiai, Mitsumoto; Matsuyama, Seiya

    1982-01-01

    Forty-two patients with valvular heart diseases were studied with a third-generation computed tomographic system. The cardiac chambers (the atria and ventricles) were evaluated semiquantitatively, and valvular calcification was easily detected with computed tomography. Computed tomography was most valuable in revealing left atrial thrombi which were not identified by other diagnostic procedures in some cases. (author)

  8. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  9. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  11. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  12. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    International Nuclear Information System (INIS)

    Palas, J.; Matos, A.P.; Ramalho, M.; Mascarenhas, V.; Heredia, V.

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  13. Patellofemoral joint motion: Evaluation by ultrafast computed tomography

    International Nuclear Information System (INIS)

    Stanford, W.; Phelan, J.; Kathol, M.H.; Rooholamini, S.A.; El-Khoury, G.Y.; Palutsis, G.R.; Albright, J.P.

    1988-01-01

    Patellofemoral maltracking is a recognized cause of peripatellar pain. Clinicians currently rely on observation, palpation, and static radiographic images to evaluate the symptomatic patient. Ultrafast computed tomography (ultrafast CT) offers objective observations of the dynamic influences of muscle contraction on the patellofemoral joint as the knee is actively moved through a range of motion from 90 0 C flexion of full extension. This study reports our initial observations and establishes a range of normal values so that patients with a clinical suspicion of patellar maltracking may be evaluated. (orig./GDG)

  14. Patellofemoral joint motion: Evaluation by ultrafast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Stanford, W.; Phelan, J.; Kathol, M.H.; Rooholamini, S.A.; El-Khoury, G.Y.; Palutsis, G.R.; Albright, J.P.

    1988-10-01

    Patellofemoral maltracking is a recognized cause of peripatellar pain. Clinicians currently rely on observation, palpation, and static radiographic images to evaluate the symptomatic patient. Ultrafast computed tomography (ultrafast CT) offers objective observations of the dynamic influences of muscle contraction on the patellofemoral joint as the knee is actively moved through a range of motion from 90/sup 0/C flexion of full extension. This study reports our initial observations and establishes a range of normal values so that patients with a clinical suspicion of patellar maltracking may be evaluated. (orig./GDG).

  15. Clinical evaluation of adrenal computed tomography and scintigraphy

    International Nuclear Information System (INIS)

    Hayasaka, Kazumasa; Yoshikawa, Hiroyuki; Asano, Akira; Kikuchi, Yuzo; Amo, Kazuo

    1983-01-01

    In 15 cases with adrenal lesion, we studied the clinical usefulness of computed tomography (CT) and scintigram. CT and RI have been successfully to locate adrenal funtioning cortical tumors (6/6) as small as 10 mm in diameter. In 5 adrenal non-funtioning cortical and medullary disorders, RI finding only shows RI activity is decreasing, but CT may be helpful in differential diagnosis. At present, CT is a reliable technique for locating adrenal disorders, and we should suggest that it should be the initial radiographic investigation. (author)

  16. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  17. In vivo formation and repair of DNA double-strand breaks after computed tomography examinations

    OpenAIRE

    Löbrich, Markus; Rief, Nicole; Kühne, Martin; Heckmann, Martina; Fleckenstein, Jochen; Rübe, Christian; Uder, Michael

    2005-01-01

    Ionizing radiation can lead to a variety of deleterious effects in humans, most importantly to the induction of cancer. DNA double-strand breaks (DSBs) are among the most significant genetic lesions introduced by ionizing radiation that can initiate carcinogenesis. We have enumerated γ-H2AX foci as a measure for DSBs in lymphocytes from individuals undergoing computed tomography examination of the thorax and/or the abdomen. The number of DSBs induced by computed tomography examination was fou...

  18. Computed tomography findings in convergent strabismus fixus

    International Nuclear Information System (INIS)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio

    1995-01-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author)

  19. Technological Evolution on Computed Tomography and Radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho [Servico de Radiologia, Hospital de Curry Cabral, Rua da Beneficencia, 8, 1069-166 Lisboa (Portugal)

    2006-05-15

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  20. Computed tomography of the traumatized abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki [Wallace Memotial Baptist Hospital, Pusan (Korea, Republic of)

    1989-02-15

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries.

  1. Computed tomography of the traumatized abdomen

    International Nuclear Information System (INIS)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki

    1989-01-01

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries

  2. Multidetector Computed Tomography and Neuroendocrine Pancreaticoduodenal Tumors

    International Nuclear Information System (INIS)

    Rappeport, E.D.; Palnaes Hansen, C.; Kjaer, A.; Knigge, U.

    2006-01-01

    Purpose: To investigate the accuracy of dedicated pancreatic multidetector computed tomography (MDCT) in the diagnosis of neuroendocrine pancreaticoduodenal tumors (NPTs). Material and Methods: MDCT and other imaging studies in patients with suspected NPTs were identified. Thirty dedicated MDCT studies were done in 23 patients. Fourteen patients (16 operations) subsequently had surgery. Imaging reports were reviewed and findings compared with surgical findings and findings in other imaging studies. Results: Patients with surgery : 19 NPTs (16 extrapancreatic gastrinomas and 3 pancreatic NPTs) were identified at surgery. MDCT identified 16 and somatostatin receptor scintigraphy (SRS) 11 out of 19 tumors. Endoscopic ultrasound detected 11 out of 14 NPTs. Patients without surgery : In 4 out of 9 patients, no NPTs were identified at MDCT. Conclusion: Dedicated MDCT of the pancreas can identify many NPTs, including small duodenal and periduodenal tumors, and the detection rate is better than reported in the older literature on CT

  3. Quality control in quantitative computed tomography

    International Nuclear Information System (INIS)

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  4. Technological Evolution on Computed Tomography and Radioprotection

    International Nuclear Information System (INIS)

    Leite, Bruno Barros; Ribeiro, Nuno Carrilho

    2006-01-01

    Computed Tomography (CT) has been available since the 70s and has experienced a dramatic technical evolution. Multi-detector technology is our current standard, offering capabilities unthinkable only a decade ago. Yet, we must nor forget the ionizing nature of CT's scanning energy (X-rays). It represents the most important cause of medical-associated radiation exposure to the general public, with a trend to increase. It is compulsory to intervene with the objective of dose reduction, following ALARA policies. Currently there are some technical advances that allow dose reduction, without sacrificing diagnostic image capabilities. However, human intervention is also essential. We must keep investment on education so that CT exams are don when they are really useful in clinical decision. Alternative techniques should also be considered. Image quality must not be searched disregarding the biological effects of radiation. Generally, it is possible to obtain clinically acceptable images with lower dose protocols. (author)

  5. The temporomandibular joint in computed tomography

    International Nuclear Information System (INIS)

    Pomaroli, A.; Lener, M.

    1988-01-01

    The first part describes details of the temporomandibular joint (TMJ) which are of interest for the examination by computed tomography. In the second part three new planes of reference for scanning of the ventral, middle or dorsal part of the joint are presented. CT examinations were made of 14 TMJ of corpses to identify the medial or ventral parts of the articular disc, medial wall of the articular capsule and medial or triangular recessus to achieve this were scanned the corpses with opened and closed mouth, as well as with closed sets of teeth using a sort of hypomochlion in the molar region to distract the TMJ. More over we applicated different contrast mediums like air and niob. (orig.) [de

  6. Neutron stimulated emission computed tomography: Background corrections

    International Nuclear Information System (INIS)

    Floyd, Carey E.; Sharma, Amy C.; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q.; Harrawood, Brian P.; Tourassi, Georgia D.; Lo, Joseph Y.; Kiser, Matthew R.; Crowell, Alexander S.; Pedroni, Ronald S.; Macri, Robert A.; Tajima, Shigeyuki; Howell, Calvin R.

    2007-01-01

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each

  7. Computed tomography study of otitis media

    International Nuclear Information System (INIS)

    Bahia, Paulo Roberto Valle; Marchiori, Edson

    1997-01-01

    The findings of computed tomography (CT) of 89 patients clinically suspected of having otitis media were studied in this work. Such results were compared to clinical diagnosis, otoscopy, surgical findings and previous data. Among the results of our analysis, we studied seven patients with acute otitis media and 83 patients with chronic otitis media. The patients with acute otitis media have undergone CT examinations to evaluate possible spread to central nervous system. The diagnosis of cholesteatoma, its extension and complications were the main indication. for chronic otitis media study. The main findings of the cholesteatomatous otitis were the occupation of the epitympanun, the bony wall destruction and the ossicular chain erosion. The CT demonstrated a great sensibility to diagnose the cholesteatoma. (author)

  8. Diagnosis of cerebral disorders using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, K [Tokyo Women' s Medical Coll. (Japan)

    1980-01-01

    Computed tomography (CT), which makes differential diagnosis of cerebral disorders possible, was applied in the diagnosis of hypertensive intracerebral hemorrhage, cerebral thrombosis, subarachnoid hemorrhage, and cerebrovascular Moyamoya disease. CT findings of hypertensive intracerebral hemorrhage showed the localization, volume, and direction of hematoma, and the classification of hematoma according to CT findings was highly correlated to the clinical symptoms of the patients. CT findings of cerebral thrombosis showed the extension of the lesion to be a low density area, but there were many cases in which they did not show a low density area immediately after an attack. CT findings of subarachnoid hemorrhage were very useful in the diagnosis of intracerebral hematoma, ventricular hematoma, and intracranial hematoma secondary to this disease. However, it was very difficult to diagnose cerebrovascular Moyamoya disease by means of CT.

  9. Diagnosis of cerebral disorders using computed tomography

    International Nuclear Information System (INIS)

    Kitamura, Koichi

    1980-01-01

    Computed tomography (CT), which makes differential diagnosis of cerebral disorders possible, was applied in the diagnosis of hypertensive intracerebral hemorrhage, cerebral thrombosis, subarachnoid hemorrhage, and cerebrovascular Moyamoya disease. CT findings of hypertensive intracerebral hemorrhage showed the localization, volume, and direction of hematoma, and the classification of hematoma according to CT findings was highly correlated to the clinical symptoms of the patients. CT findings of cerebral thrombosis showed the extension of the lesion to be a low density area, but there were many cases in which they did not show a low density area immediately after an attack. CT findings of subarachnoid hemorrhage were very useful in the diagnosis of intracerebral hematoma, ventricular hematoma, and intracranial hematoma secondary to this disease. However, it was very difficult to diagnose cerebrovascular Moyamoya disease by means of CT. (Nishio, M.)

  10. The dynamic micro computed tomography at SSRF

    Science.gov (United States)

    Chen, R.; Xu, L.; Du, G.; Deng, B.; Xie, H.; Xiao, T.

    2018-05-01

    Synchrotron radiation micro-computed tomography (SR-μCT) is a critical technique for quantitative characterizing the 3D internal structure of samples, recently the dynamic SR-μCT has been attracting vast attention since it can evaluate the three-dimensional structure evolution of a sample. A dynamic μCT method, which is based on monochromatic beam, was developed at the X-ray Imaging and Biomedical Application Beamline at Shanghai Synchrotron Radiation Facility, by combining the compressed sensing based CT reconstruction algorithm and hardware upgrade. The monochromatic beam based method can achieve quantitative information, and lower dose than the white beam base method in which the lower energy beam is absorbed by the sample rather than contribute to the final imaging signal. The developed method is successfully used to investigate the compression of the air sac during respiration in a bell cricket, providing new knowledge for further research on the insect respiratory system.

  11. Computed tomography of the pituitary gland

    International Nuclear Information System (INIS)

    Bonneville, J.F.; Cattin, F.; Dietemann, J.L.

    1986-01-01

    This book is written entirely to include the imaging of the pituitary gland by computed tomography (CT). The first three chapters illustrated technical aspects of scanning, anatomic depiction of the gland by CT, and the use of dynamic CT scanning for detecting and displaying abnormalities. The chapters discuss and illustrate various types of pathologic processes in and around the pituitary gland. One short but very helpful chapter demonstrates potential pitfalls due to the combination of anatomic variants and the geometry of CT sections. Some illustrations of disease processed are depicted by magnetic resonance imaging. All major types of pituitary diseases are illustrated. Lists of readily available English-language references are available. A small subject index is provided at the end of the book in which the illustrations are identified by use of a special numeric front

  12. Ward nurses' knowledge of computed tomography scanning.

    Science.gov (United States)

    Majeed, M A; Nayeemuddin, M; Christie, M

    Patients benefit from and are reassured by advance information on procedures that they are to undergo. Ward nurses should have adequate knowledge of radiological investigations to ensure proper patient preparation and good interdepartmental communication to avoid delays and cancellations. This study was conducted to assess the ward nurses' knowledge of the process of computed tomography (CT) scanning. One hundred and twenty qualified nurses were asked to complete a questionnaire regarding CT scanning. The findings revealed a suboptimal level of awareness about the process. This is probably due to lack of formal teaching for nurses on the wards in regards the different radiological procedures and patient preparation. There is a strong case for better educational talks on rapidly changing radiological techniques for ward staff to ensure high-quality patient care.

  13. Computed tomography study of Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Arai, H; Kobayashi, K; Ikeda, Y; Nagao, Y; Ogihara, R; Kosaka, K

    1983-01-01

    Computed tomography (CT) was used to study cerebral atrophy in 18 patients with clinically diagnosed Alzheimer's disease of presenile type and in 14 healthy age-matched subjects as controls. Using the computerized planimetric method, Subarachnoid Space Volume Index and Ventricle Volume Index were calculated as the measure of cortical atrophy and ventricular dilatation respectively. From the results the following conclusions were drawn: 1. The cerebral atrophy in Alzheimer patients could be attributable to the disease processes rather than to physiological aging of the brain. 2. The degree of atrophy increases in parallel with the progress of the clinical stage, and the cortical atrophy is already apparent at an early stage, whereas the ventricular dilatation becomes pronounced at later stages. 3. CT could be one of the most useful clinical tests available for the diagnosis of Alzheimer's disease.

  14. Practical techniques for pediatric computed tomography

    International Nuclear Information System (INIS)

    Fitz, C.R.; Harwood-Nash, D.C.; Kirks, D.R.; Kaufman, R.A.; Berger, P.E.; Kuhn, J.P.; Siegel, M.J.

    1983-01-01

    Dr. Donald Kirks has assembled this section on Practical Techniques for Pediatric Computed Tomography. The material is based on a presentation in the Special Interest session at the 25th Annual Meeting of the Society for Pediatric Radiology in New Orleans, Louisiana, USA in 1982. Meticulous attention to detail and technique is required to ensure an optimal CT examination. CT techniques specifically applicable to infants and children have not been disseminated in the radiology literature and in this respect it may rightly be observed that ''the child is not a small adult''. What follows is a ''cookbook'' prepared by seven participants and it is printed in Pediatric Radiology, in outline form, as a statement of individual preferences for pediatric CT techniques. This outline gives concise explanation of techniques and permits prompt dissemination of information. (orig.)

  15. Teleradiology for emergency cranial computed tomography

    International Nuclear Information System (INIS)

    Stranzinger, E.; Treumann, T.C.; Dreier, D.; Allgayer, B.

    2003-01-01

    Purpose: We report our experience with the teleradiologic service provided by a center hospital (CH) for emergency cranial computed tomography (CCT) in two regional hospitals (RH) during a 12-month period. The clinical and economic impact of teleradiology will be discussed as well as the acceptance by the clinicians of the regional hospitals. Material and Methods: In 2001, 213 CT-scans in 202 patients were performed and reported using teleradiology. Teleradiologic and final medical diagnosis were analysed by the medical reports. The transferral of the patients to a CH and their further treatment were checked. The referring physicians in the RH were questionnaired about the teleradiological support. Results: 18 (9%) patients had to be urgently transferred to a CH based on the CT findings in the teleradiological reports. 24 patients (11%) were transferred to a center hospital during further treatment. 80% of patients were treated in the RH. (orig.) [de

  16. Quality assurance of computed tomography (CT) scanners

    International Nuclear Information System (INIS)

    Sankaran, A.; Sanu, K.K. . Email : a_sankaran@vsnl.com

    2004-01-01

    This article reviews the present status of research work and development of various test objects, phantoms and detector/instrumentation systems for quality assurance (QA) of computed tomography (CT) scanners, carried out in advanced countries, with emphasis on similar work done in this research centre. CT scanner is a complex equipment and routine quality control procedures are essential to the maintenance of image quality with optimum patient dose. Image quality can be ensured only through correlation between prospective monitoring of system components and tests of overall performance with standard phantoms. CT examinations contribute a large share to the population dose in advanced countries. The unique dosimetry problems in CT necessitate special techniques. This article describes a comprehensive kit developed indigenously for the following QA and type approval tests as well as for research studies on image quality/dosimetry on CT scanners

  17. Minimising medically unwarranted computed tomography scans

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    As computed tomography (CT) is such a superb diagnostic tool and individual CT risks are small, whenever a CT scan is clinically warranted, the CT benefit/risk balance is by far in the patient’s favour. However, if a CT scan is not clinically warranted, this balance shifts dramatically. It is likely that at least 25% of CT scans fall into this latter category, in that they could either be replaced with alternative imaging modalities or could be avoided entirely. Use of clinical decision rules for CT usage represents a powerful approach for slowing down the increase in CT usage, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they may not be clinically helpful.

  18. Computed tomography of radioactive objects and materials

    International Nuclear Information System (INIS)

    Sawicka, B.D.; Murphy, R.V.; Tosello, G.; Reynolds, P.W.; Romaniszyn, T.

    1990-01-01

    Computed tomography (CT) has been performed on a number of radioactive objects and materials. Several unique technical problems are associated with CT of radioactive specimens. These include general safety considerations, techniques to reduce background-radiation effects on CT images and selection criteria for the CT source to permit object penetration and to reveal accurate values of material density. In the present paper, three groups of experiments will be described, for objects with low, medium and high levels of radioactivity. CT studies on radioactive specimens will be presented. They include the following: (1) examination of individual ceramic reactor-fuel (uranium dioxide) pellets, (2) examination of fuel samples from the Three Mile Island reactor, (3) examination of a CANDU (CANada Deuterium Uranium: registered trademark) nuclear-fuel bundle which underwent a simulated loss-of-coolant accident resulting in high-temperature damage and (4) examination of a PWR nuclear-reactor fuel assembly. (orig.)

  19. System Matrix Analysis for Computed Tomography Imaging

    Science.gov (United States)

    Flores, Liubov; Vidal, Vicent; Verdú, Gumersindo

    2015-01-01

    In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data. PMID:26575482

  20. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  1. Data processing device for computed tomography system

    International Nuclear Information System (INIS)

    Nakayama, N.; Ito, Y.; Iwata, K.; Nishihara, E.; Shibayama, S.

    1984-01-01

    A data processing device applied to a computed tomography system which examines a living body utilizing radiation of X-rays is disclosed. The X-rays which have penetrated the living body are converted into electric signals in a detecting section. The electric signals are acquired and converted from an analog form into a digital form in a data acquisition section, and then supplied to a matrix data-generating section included in the data processing device. By this matrix data-generating section are generated matrix data which correspond to a plurality of projection data. These matrix data are supplied to a partial sum-producing section. The partial sums respectively corresponding to groups of the matrix data are calculated in this partial sum-producing section and then supplied to an accumulation section. In this accumulation section, the final value corresponding to the total sum of the matrix data is calculated, whereby the calculation for image reconstruction is performed

  2. MicroComputed Tomography: Methodology and Applications

    International Nuclear Information System (INIS)

    Stock, Stuart R.

    2009-01-01

    Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

  3. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  4. Computer tomography of intracranial tumours and hematomas

    International Nuclear Information System (INIS)

    Tans, J.T.J.

    1978-01-01

    The value of computed tomography (CT) for the diagnosis of intracranial tumors and hematomas was investigated in a retrospective study comprising 220 patients. All C.T.scans are reviewed and described in detail. To assess the diagnostic accuracy, the original interpretation of the C.T.scans was compared with that of conventional neuroradiological and neurophysiological examinations. The aspect on C.T. of the various types of tumors and hematomas proved to vary widely and specific features were seldom seen. This holds particularly for the malignant tumors. Benign tumors such as meningeomas, adenomas and neurilemmomas showed a rather easily identifiable and almost identical picture of the C.T.scan, and diagnosis had to be based mainly on differences in localization. The hematomas, with the exception of the older intracerebral ones, showed the most characteristic C.T.abnormalities. (Auth.)

  5. Computed tomography of the abnormal thymus

    International Nuclear Information System (INIS)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion

  6. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  7. Computed tomography of Rathke's cleft cyst

    International Nuclear Information System (INIS)

    Shiokawa, Yoshiaki; Teramoto, Akira; Mayanagi, Yoshiaki; Hanamura, Tetsu; Noguchi, Makoto; Takakura, Kintomo.

    1986-01-01

    The computed tomography (CT) findings in six cases of Rathke's cleft cyst (RCC) were presented. According to the location of the RCC, we divided these cases into two types - the suprasellar type and the intrasellar type. The characteristic CT findings are as follows: SUPRASELLAR type 1. smooth, round mass, 2. various densities, 3. no enhancement, INTRASELLAR type 1. low-density area in the posterior sella turcica, 2. no enhancement, 3. suprasellar high-density mass; enhanced pituitary gland pushed up by the intrasellar RCC. As RCC are more common than was formerly suspected, this disease should always be considered in the differential diagnosis of a patient showing a non-enhancing, non-calcified sellar/suprasellar cyst on CT scans. (author)

  8. Computed tomography of Rathke's cleft cyst

    Energy Technology Data Exchange (ETDEWEB)

    Shiokawa, Yoshiaki; Teramoto, Akira; Mayanagi, Yoshiaki; Hanamura, Tetsu; Noguchi, Makoto; Takakura, Kintomo

    1986-02-01

    The computed tomography (CT) findings in six cases of Rathke's cleft cyst (RCC) were presented. According to the location of the RCC, we divided these cases into two types - the suprasellar type and the intrasellar type. The characteristic CT findings are as follows: SUPRASELLAR type 1. smooth, round mass, 2. various densities, 3. no enhancement, INTRASELLAR type 1. low-density area in the posterior sella turcica, 2. no enhancement, 3. suprasellar high-density mass; enhanced pituitary gland pushed up by the intrasellar RCC. As RCC are more common than was formerly suspected, this disease should always be considered in the differential diagnosis of a patient showing a non-enhancing, non-calcified sellar/suprasellar cyst on CT scans.

  9. A computed tomography study of Alzheimer's disease

    International Nuclear Information System (INIS)

    Arai, H.; Kobayashi, K.; Juntendo Univ. School of Medicine, Tokyo; Ikeda, Y.; Nagao, Y.; Ogihara, R.; Kosaka, K.; Psychiatric Research Inst. of Tokyo

    1983-01-01

    Computed tomography (CT) was used to study cerebral atrophy in 18 patients with clinically diagnosed Alzheimer's disease of presenile type and in 14 healthy age-matched subjects as controls. Using the computerized planimetric method, Subarachnoid Space Volume Index and Ventricle Volume Index were calculated as the measure of cortical atrophy and ventricular dilatation respectively. From the results the following conclusions were drawn: 1. The cerebral atrophy in Alzheimer patients could be attributable to the disease processes rather than to physiological aging of the brain. 2. The degree of atrophy increases in parallel with the progress of the clinical stage, and the cortical atrophy is already apparent at an early stage, whereas the ventricular dilatation becomes pronounced at later stages. 3. CT could be one of the most useful clinical tests available for the diagnosis of Alzheimer's disease. (orig.) [de

  10. Computed Tomography findings in Fournier's gangrene

    International Nuclear Information System (INIS)

    Isusi, M.; Campo, M.; Oleaga, L.; Grande, J.; Grande, D.

    2000-01-01

    To assess the utility of computed tomography (CT) as an imaging technique in the diagnosis and determination of the extension of Fournier's gangrene (FG). We report the cases of six patients who had been clinically diagnosed as having FG, CT, enhanced by oral and intravenous contrast media, was performed in all the patients. All six patients presented soft tissue masses and gas in the scrotal region, which were also detected in the perineal region in five. In two patients, the gas extended toward anterior abdominal wall and in one of them, it also observed in anterior and posterior para renal space. The major predisposing factors were diabetes and alcoholism and the most common triggering factor was urologic disease. CT confirms the existence of FG and aids in assessing its extension and, in some cases, in identifying the underlying cause. (Author) 15 refs

  11. Minamata disease demonstrated by computed tomography

    International Nuclear Information System (INIS)

    Matsumoto, S.C.; Okajima, T.; Inayoshi, S.; Ueno, H.

    1988-01-01

    Computed tomography was studied in the patients with Minamata disease, a methylmercury poisoning caused by the ingestion of contaminated sea foods. The characteristic changes in the acquired cases were atrophy of the visual calcarine cortex and of the cerebellar vermis and or hemisphere. Marked atrophy of the calcarine cortex produced the sac-shaped low density areas between the occipital lobes and diffuse and marked cerebellar atrophy with enlargement of the fourth ventricle and cisterns of the posterior fossa produced a shrunken image on CT. Morphometric analysis confirmed these findings. In the fetal cases, the changes on CT were slight and no definite atrophy was demonstrated in either the calcarine cortex or the cerebellum. Morphometric analysis disclosed an increase of size of the middle portions of the lateral ventricle and the third and fourth ventricles. (orig.)

  12. Computed tomography findings of malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka (Kure Kyosai Hospital, Hiroshima (Japan))

    1994-04-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author).

  13. Computed tomography findings of malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka

    1994-01-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author)

  14. Computed tomography angiogram. Accuracy in renal surgery

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Al-Hathal, Naif; Al-Fuhaid, Turki; Raza, Sayed; Al-Yami, Fahad; Al-Taweel, Waleed; Alomar, Mohamed; Al-Nagshabandi, Nizar

    2009-01-01

    The objective of this study was to determine the sensitivity and specificity of computed tomography angiogram (CTA) in detecting number and location of renal arteries and veins as well as crossing vessels causing uretero-pelvic junction obstruction (UPJO), and to determine if this can be used in decision-making algorithms for treatment of UPJO. A prospective study was carried out in patients undergoing open, laparoscopic and robotic renal surgery from April 2005 until October 2006. All patients were imaged using CTA with 1.25 collimation of arterial and venous phases. Each multi-detector CTA was then read by one radiologist and his results were compared prospectively with the actual intra-operative findings. Overall, 118 patients were included. CTA had 93% sensitivity, 77% specificity and 90% overall accuracy for detecting a single renal artery, and 76% sensitivity, 92% specificity and 90% overall accuracy for detecting two or more renal arteries (Pearson χ 2 =0.001). There was 95% sensitivity, 84% specificity and 85% overall accuracy for detecting the number of renal veins. CTA had 100% overall accuracy in detecting early dividing renal artery (defined as less than 1.5 cm branching from origin), and 83.3% sensitivity, specificity and overall accuracy in detecting crossing vessels at UPJ. The percentage of surgeons stating CTA to be helpful as pre-operative diagnostic tool was 85%. Computed tomography angiogram is simple, quick and can provide an accurate pre-operative renal vascular anatomy in terms of number and location of renal vessels, early dividing renal arteries and crossing vessels at UPJ. (author)

  15. Symbolic initiative and its application to computers

    Energy Technology Data Exchange (ETDEWEB)

    Hellerman, L

    1982-01-01

    The author reviews the role of symbolic initiative in mathematics and then defines a sense in which computers compute mathematical functions. This allows a clarification of the semantics of computer and communication data. Turing's view of machine intelligence is examined in terms of its use of symbolic initiative. 12 references.

  16. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  17. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  18. Diagnosis of lumbar disc hernia with computed tomography

    International Nuclear Information System (INIS)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru

    1982-01-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed. (Ueda, J.)

  19. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  20. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    Tipold, A.; Tipold, E.

    1991-01-01

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  1. Initial Reading through Computer Animation.

    Science.gov (United States)

    Geoffrion, Leo D.; Bergeron, R. Daniel

    The Computer Animated Reading Instruction System (CARIS) was developed to introduce reading to children with varied sensory, cognitive, and physical handicaps. CARIS employs an exploratory learning approach which encourages children to experiment with the reading and writing of words and sentences. Brief computer-animated cartoons provide the…

  2. GPU-based cone beam computed tomography.

    Science.gov (United States)

    Noël, Peter B; Walczak, Alan M; Xu, Jinhui; Corso, Jason J; Hoffmann, Kenneth R; Schafer, Sebastian

    2010-06-01

    The use of cone beam computed tomography (CBCT) is growing in the clinical arena due to its ability to provide 3D information during interventions, its high diagnostic quality (sub-millimeter resolution), and its short scanning times (60 s). In many situations, the short scanning time of CBCT is followed by a time-consuming 3D reconstruction. The standard reconstruction algorithm for CBCT data is the filtered backprojection, which for a volume of size 256(3) takes up to 25 min on a standard system. Recent developments in the area of Graphic Processing Units (GPUs) make it possible to have access to high-performance computing solutions at a low cost, allowing their use in many scientific problems. We have implemented an algorithm for 3D reconstruction of CBCT data using the Compute Unified Device Architecture (CUDA) provided by NVIDIA (NVIDIA Corporation, Santa Clara, California), which was executed on a NVIDIA GeForce GTX 280. Our implementation results in improved reconstruction times from minutes, and perhaps hours, to a matter of seconds, while also giving the clinician the ability to view 3D volumetric data at higher resolutions. We evaluated our implementation on ten clinical data sets and one phantom data set to observe if differences occur between CPU and GPU-based reconstructions. By using our approach, the computation time for 256(3) is reduced from 25 min on the CPU to 3.2 s on the GPU. The GPU reconstruction time for 512(3) volumes is 8.5 s. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  3. Patient Dose From Megavoltage Computed Tomography Imaging

    International Nuclear Information System (INIS)

    Shah, Amish P.; Langen, Katja M.; Ruchala, Kenneth J.; Cox, Andrea; Kupelian, Patrick A.; Meeks, Sanford L.

    2008-01-01

    Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value

  4. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  5. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1984-01-01

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  6. Computed tomography apparatus with detector sensilivity correction

    International Nuclear Information System (INIS)

    Waltham, R. M.

    1984-01-01

    In a rotary fan beam computed tomography apparatus using recurrent relative displacement between the source and detectors (e.g. a deflected spot X-ray tube) for the recalibration of detectors in chain-like sequences across the detector array by successive pairwise common-path sensitivity comparisons starting from a terminal detector each sequence normally involves or more successive comparisons, and consistent but unpredictable errors are found to occur, leading to incorrect Houndsfield values in the computed image matrix. The improvement comprises locating at least one radiation transparent detector of high stability in front of the array at an intermediate point and using the output to further correct the chain-corrected detector sensitivity values. A detector comprising a plastics scintillator optically coupled to a photomultiplier is described, whose output pulses are counted during a rotational scan and compared with the mean corresponding measurement from detectors lying behind the detector, to form a sensitivity ratio. From a corresponding ratio and data derived during calibration, a measured sensitivity value for detectors is determined for each scan and is compared with the corresponding chain-corrected sensitivity value to generate a further sensitivity correction value which is then distributed among the detectors of the comparison sequence

  7. Correction for polychromatic aberration in computed tomography images

    International Nuclear Information System (INIS)

    Naparstek, A.

    1979-01-01

    A method and apparatus for correcting a computed tomography image for polychromatic aberration caused by the non-linear interaction (i.e. the energy dependent attenuation characteristics) of different body constituents, such as bone and soft tissue, with a polychromatic X-ray beam are described in detail. An initial image is conventionally computed from path measurements made as source and detector assembly scan a body section. In the improvement, each image element of the initial computed image representing attenuation is recorded in a store and is compared with two thresholds, one representing bone and the other soft tissue. Depending on the element value relative to the thresholds, a proportion of the respective constituent is allocated to that element location and corresponding bone and soft tissue projections are determined and stored. An error projection generator calculates projections of polychromatic aberration errors in the raw image data from recalled bone and tissue projections using a multidimensional polynomial function which approximates the non-linear interaction involved. After filtering, these are supplied to an image reconstruction computer to compute image element correction values which are subtracted from raw image element values to provide a corrected reconstructed image for display. (author)

  8. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  9. Significance of computed tomography in urology

    International Nuclear Information System (INIS)

    Harada, Takashi

    1981-01-01

    There are more than five years since computed tomography (CT) was first introduced in this country for practical use. However, cumulative diagnostic experiences in urology have not been discussed thoroughly yet. In the Department of Urology of Kansai Medical University over 120 times CT diagnosis were attempted past three years and the instrument employed during this period has been alternative from the first generation type (ACTA 150) to the third one (CT-3W) this year as to technical advance. These cases are 70 of pelvic lesions and retroperitoneal surveys are made in the rests. As a results, detection of space occupying mass in kidney, adrenal and their surroundings was comparatively easy to deliver by this method, but there are several pitfalls to come misunderstanding in diagnosis of pelvic organs. It seems to be difficult to obtain certain result on closely packed viscera with tightly adhered connective tissue in tiny space. However, these difficulties will be solved by bladder insufflation with olive oil, for instance, and scanning in prone position. Contrast enhancement by injection of dye also give more definite results in genitourinary tract assessment. Moreover, there are much benefit in diagnosis of renal parenchymal change including lacerating renal trauma unable to be differentiated conventional method. Bolus injection of contrast material also allows to calculate CT values obtained from ROI on tomography and enables to fit the value to time-activity curve likewise scintillation scanning. In forthcomming day, new device in this field including emission-CT, NMR-CT and others will open new sight for ideal diagnostic facility in urology. (author)

  10. A stereotactic adapter compatible with computed tomography

    International Nuclear Information System (INIS)

    Cacak, R.K.; Law, J.D.

    1982-01-01

    One application of computed-tomographic (CT) scanners is the localization of intracranial targets for stereotactic surgery. Unfortunately, conventional stereotactic devices affixed to the patient cause artifacts which obscure anatomic features in CT images. The authors describe the initial phase of a project to eliminate this problem by using an adapter that is free of metallic objects. Localization of the target point relative to the coordinate system of a Leksell stereotactic frame is achieved from CT image measurements

  11. Computed tomography and radioprotection: Knowing and acting

    International Nuclear Information System (INIS)

    Ducou Le Pointe, H.

    2013-01-01

    Exposure of the population to ionizing radiation for medical purposes is increasing throughout the world. In the United States of America, this exposure (3 mSv) has reached, even exceeded, exposure from natural sources. In France, the report of the French Institute for Radiological Protection and Nuclear Safety (IRSN) on exposure of the French population to ionizing radiation in 2007, based on the 74.6 million medical diagnostic procedures, estimates the mean individual effective dose to be 1.3 mSv. This value is much lower than the value in the United States but has progressed in 5 years by 62.5%. Computed tomography accounts for 10.1% of the procedures and 58% of the collective effective dose. This is why computed tomography is receiving very special attention from all those involved in radioprotection. It must be remembered, nevertheless, that we are well within the low dose range (effective dose less than 100 mSv), and indeed, in the large majority of CT examinations exposure values are lower than 15 mSv. The biological effects of low doses are still a matter of debate. First of all, it has not been possible to demonstrate the risk of cancer due to this level of exposure, neither on the survivors of the atomic bombs in Japan nor on workers in the nuclear industry in the United Kingdom. The year 2012 marked a change; for the first time, epidemiology took over from statistical studies. Despite the low risk demonstrated, reserves concerning methodology, and waiting for further European epidemiological studies underway, we must continue to act to encourage radiological protection. Before considering the action to take and without under-estimating the risks, it is important to remember that a computed tomography investigation is conducted in patients, and not in individuals in good health. Acting to provide patients with protection from radiation means involving all those concerned with justifying it, with substituting it, and with optimising it. For some years

  12. Computed Tomography of pediatric head trauma

    International Nuclear Information System (INIS)

    Shin, Kyoung Hee; Cho, Bum Shin; Hahm, Chang Kok

    1982-01-01

    The development of Computed Tomography (CT) scanning has revolutionized the role of radiology in the management of the pediatric head trauma. The procedure is safe and can be repeated to reasses a changing neurologic picture, thereby correlation the clinical and pathologic changes. This study included evaluation of CT of 178 infants and children with head trauma during the period of 31 months from Feb. 1979 to Aug. 1981 in the Department of Radiology, College of Medicine, Hanyang University. 1. Age distribution of the total 178 pediatric patients was ranging from one month to 16 years. The pediatric patient population was comprised of 128 males and 50 females, and its male to female ratio was about 2.5 : 1. The incidence of age occurring in 3 to 6 years was 38.2% and 7 to 10 years was 29.2%. Therefore the distribution of age between 3 to 6 years and 7 to 10 years was occurred in two-thirds of all pediatric patients. 2. Of all cases of injuries, traffic accidents were 60.1% and falls were 34.8%. 3. Skull fracture were roentgenographically detected in 61 (34.3%). However, the incidence of fractures in pretoddler group (0-2 years) was 61.1% and 7 to 10 years was 37.8%, 3 to 6 years was 36.8%. More common site of skull fracture was occipital bone,next partietal bone. 4. 54.8% of pediatric head trauma due to a full had a skull fracture, as did 25.2 % of those who were injured in traffic accident. 5. Cerebral Computed Tomography (CT) of the total 178 pediatric patients were revealed as following study.: Normal was 74.2%, epidural hematoma was 8.9%, subdural hematoma was 5.1%, cerebral contusion was 4.5%, intracerebral hematoma was 2.2% etc. 6. Of 25 cases of the epidural and subdural hematoma, supratentorial area was 15 cases, infratentorial area was 10 cases. 7. Most of the epidural hematoma was demonstrated a clear mental state. 8. However, intracerebral hematoma and cerebral contusion were occurred almost impairment of mental state

  13. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  14. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  15. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  16. Reproducibility in the assessment of acute pancreatitis with computed tomography

    International Nuclear Information System (INIS)

    Freire Filho, Edison de Oliveira; Vieira, Renata La Rocca; Yamada, Andre Fukunishi; Shigueoka, David Carlos; Bekhor, Daniel; Freire, Maxime Figueiredo de Oliveira; Ajzen, Sergio; D'Ippolito, Giuseppe

    2007-01-01

    Objective: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. Materials and methods: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (κ). Results: Interobserver agreement was κ 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was κ = 0.796 and 0.732 for unenhanced morphological index; κ 0.725 and 0.802 for contrast- enhanced morphological index; κ = 0.674 and 0.849 for presence of pancreatic necrosis; κ = 0.606 and 0.770 for pancreatic necrosis extension; and κ = 0.801 and 0.687 for disease severity index at computed tomography. Conclusion: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast- enhancement does not affect the computed tomography morphological index reproducibility. (author)

  17. Kimura's disease: imaging patterns on computed tomography

    International Nuclear Information System (INIS)

    Gopinathan, Anil; Tan, T.Y.

    2009-01-01

    Aim: To define the role of computed tomography (CT) in identifying and classifying the imaging patterns of diagnostic value in Kimura's disease of the head and neck. Methods: A retrospective study was undertaken comprising 13 patients with histopathological evidence of Kimura's disease. The patients' clinical and pathological records were reviewed against a detailed analysis of their CT images performed from the base of the skull to the arch of the aorta. Results: Both well-defined, nodular masses, as well as ill-defined plaque-like infiltrative masses were seen in the subcutaneous tissue of the head and neck region. All patients had lesions adjacent to the major salivary glands. The parotid gland was affected in 10 of the 13 cases and the submandibular gland was affected in the rest. Contrast enhancement was variable. More than half of the cases had associated lymphadenopathy. Some of them showed atrophy of the skin and subcutaneous fat overlying the subcutaneous masses. Blood eosinophilia was a consistent feature in all the cases. Conclusion: The patterns of distribution, morphology, and enhancement of the lesions in Kimura's disease that can be demonstrated at CT, enables a confident, non-invasive diagnosis of this condition, in an appropriate clinical context.

  18. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  19. Virtual computed tomography cystoscopy in bladder pathologies

    International Nuclear Information System (INIS)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban

    2006-01-01

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  20. Measurements of computed tomography radiation scatter

    International Nuclear Information System (INIS)

    Van Every, B.; Petty, R.J.

    1992-01-01

    This paper describes the measurement of scattered radiation from a computed tomography (CT) scanner in a clinical situation and compares the results with those obtained from a CT performance phantom and with data obtained from CT manufacturers. The results are presented as iso-dose contours. There are significant differences between the data obtained and that supplied by manufacturers, both in the shape of the iso-dose contours and in the nominal values. The observed scatter in a clinical situation (for an abdominal scan) varied between 3% and 430% of the manufacturers' stated values, with a marked reduction in scatter noted a the head and feet of the patient. These differences appear to be due to the fact that manufacturers use CT phantoms to obtain scatter data and these phantoms do not provide the same scatter absorption geometry as patients. CT scatter was observed to increase as scan field size and slice thickness increased, whilst there was little change in scatter with changes in gantry tilt and table slew. Using the iso-dose contours, the orientation of the CT scanner can be optimised with regard to the location and shielding requirements of doors and windows. Additionally, the positioning of staff who must remain in the room during scanning can be optimised to minimise their exposure. It is estimated that the data presented allows for realistic radiation protection assessments to be made. 13 refs., 5 tabs., 6 figs

  1. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Tingey, D.R.C.

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors)

  2. Computed tomography findings in pancreas divisum

    International Nuclear Information System (INIS)

    Lindstroem, E.; Ihse, I.

    1989-01-01

    In 29 patients with abdominal pain the diagnosis of pancreas divisum (PD) was verified by endoscopic retrograde pancreatography (EPR) via both the major and the minor papilla. Computed tomography (CT) was done in all patients to evaluate contour, volume, antero-posterior diameters and attenuation values of the gland in comparison with a normal reference series. Also, the validity of the CT grading of pancreatitis was assessed in comparison with ERP grading. Patients with PD had an increased cranio-caudal diameter of the pancreatic head (p<0.001). Further, the main pancreatic duct was visualized more often in patients with PD (p<0.01), who also had an increasing frequency of pancreatic calcifications (p<0.05). Otherwise there were no differences compared with the normal series. The observed reduction in the volume of the gland in patients with marked pancreatitis at ERP seemingly reflected the severity of inflammation. No cleavage between the dorsal and ventral anlage was identified. CT was found to be too unspecific to be of any use in grading of pancreatitis. In conclusion, CT findings in patients with PD are sparse, unspecific and preferably a reflection of pancreatitis, if present. ERP remains the ''gold standard'' for the diagnosis. (orig.)

  3. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  4. Medullary sponge kidney on axial computed tomography

    International Nuclear Information System (INIS)

    Ginalski, J.-M.; Schnyder, Pierre; Portmann, Luc; Jaeger, Philippe

    1991-01-01

    To evaluate features of medullary sponge kidney (MSK) on computed tomography (CT), 4-mm-thick axial slices without intravenous contrast material were 1st made in 13 patients through 24 kidneys which showed images of MSK on excretory urograms. On CT, papillary calcifications were found in 11 kidneys. In 5 of these, the calcifications were not detectable on plain films. Some hyperdense papillae (attenuation value 55-70 Hounsfield units) without calcification were found in 4 other kidneys. 9 kidneys appeared normal. 10 of the 14 kidneys were reexamined by a 2nd series of 4-mm-thick axial slices, 5 min after intravenous injection of 50 ml of Urografin. Images suggesting possible ectasia of precaliceal tubules were found in only 4 kidneys. These images appear much less obvious and characteristic on CT than on excretory urogram and do nothing more than suggest the possibility of MSK. In conclusion, the sensitivity of CT in the detection of MSK is markedly lower than that of excretory urography. In the most florid cases of the disease, CT can only show images suggesting the possibility of MSK. On the other hand, CT appears much more sensitive than plain films and tomograms of excretory in the detection of papillary calcifications, the most frequent complication of MSK. (author). 13 refs.; 3 figs

  5. High resolution computed tomography of positron emitters

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Cahoon, J.L.; Huesman, R.H.; Jackson, H.G.

    1976-10-01

    High resolution computed transaxial radionuclide tomography has been performed on phantoms containing positron-emitting isotopes. The imaging system consisted of two opposing groups of eight NaI(Tl) crystals 8 mm x 30 mm x 50 mm deep and the phantoms were rotated to measure coincident events along 8960 projection integrals as they would be measured by a 280-crystal ring system now under construction. The spatial resolution in the reconstructed images is 7.5 mm FWHM at the center of the ring and approximately 11 mm FWHM at a radius of 10 cm. We present measurements of imaging and background rates under various operating conditions. Based on these measurements, the full 280-crystal system will image 10,000 events per sec with 400 μCi in a section 1 cm thick and 20 cm in diameter. We show that 1.5 million events are sufficient to reliably image 3.5-mm hot spots with 14-mm center-to-center spacing and isolated 9-mm diameter cold spots in phantoms 15 to 20 cm in diameter

  6. Computed tomography with selectable image resolution

    International Nuclear Information System (INIS)

    Dibianca, F.A.; Dallapiazza, D.G.

    1981-01-01

    A computed tomography system x-ray detector has a central group of half-width detector elements and groups of full-width elements on each side of the central group. To obtain x-ray attenuation data for whole body layers, the half-width elements are switched effectively into paralleled pairs so all elements act like full-width elements and an image of normal resolution is obtained. For narrower head layers, the elements in the central group are used as half-width elements so resolution which is twice as great as normal is obtained. The central group is also used in the half-width mode and the outside groups are used in the full-width mode to obtain a high resolution image of a body zone within a full body layer. In one embodiment data signals from the detector are switched by electronic multiplexing and in another embodiment a processor chooses the signals for the various kinds of images that are to be reconstructed. (author)

  7. Computed tomography shielding methods: a literature review.

    Science.gov (United States)

    Curtis, Jessica Ryann

    2010-01-01

    To investigate available shielding methods in an effort to further awareness and understanding of existing preventive measures related to patient exposure in computed tomography (CT) scanning. Searches were conducted to locate literature discussing the effectiveness of commercially available shields. Literature containing information regarding breast, gonad, eye and thyroid shielding was identified. Because of rapidly advancing technology, the selection of articles was limited to those published within the past 5 years. The selected studies were examined using the following topics as guidelines: the effectiveness of the shield (percentage of dose reduction), the shield's effect on image quality, arguments for or against its use (including practicality) and overall recommendation for its use in clinical practice. Only a limited number of studies have been performed on the use of shields for the eyes, thyroid and gonads, but the evidence shows an overall benefit to their use. Breast shielding has been the most studied shielding method, with consistent agreement throughout the literature on its effectiveness at reducing radiation dose. The effect of shielding on image quality was not remarkable in a majority of studies. Although it is noted that more studies need to be conducted regarding the impact on image quality, the currently published literature stresses the importance of shielding in reducing dose. Commercially available shields for the breast, thyroid, eyes and gonads should be implemented in clinical practice. Further research is needed to ascertain the prevalence of shielding in the clinical setting.

  8. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir

    2016-09-06

    Wavefield tomography can handle complex subsurface geology better than ray-based techniques and, ultimately, provide a higher resolution. Here, we implement forward and adjoint wavefield extrapolation for VTI (transversely isotropic with a vertical symmetry axis) media using a pseudospectral operator that employes a separable approximation of the P-wave dispersion relation. This operator is employed to derive the gradients of the differential semblance optimization (DSO) and modified stack-power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space-time finite-difference (FD) scheme for a system of coupled wave equations. Whereas the kernels computed with the two wave-equation operators are similar, the pseudospectral method is not hampered by the imprint of the shear-wave artifact. Numerical examples also show that the modified stack-power objective function produces cleaner gradients than the more conventional DSO operator.

  9. Cranial computed tomography in infantile spasms

    International Nuclear Information System (INIS)

    Howitz, P.; Neergaard, K.; Pedersen, H.

    1990-01-01

    Out of 109 children with infantile spasms (IS), prospectively tested during the years 1976 to 1979 in Denmark, 52 children were examined by cranial computed tomography (CT). The classification of IS into cryptogenic (CR), symptomatic (SY) and doubtful (DO) was done clinically without considering the CT-finding. Sixty per cent of the scannings were abnormal. Only 6/30 (20%) of the children in ACTH treatment were found to develop cerebral atrophy which means that this finding is not an obligatory side-effect of ACTH treatment of children with IS. Normal CT-findings were found in 50% of the CR and 50% of the SY + DO-groups, and could not be used as a prognostic tool for estimating the mental development. This was also the case for children with cerebral atrophy. Abnormal CT-findings (minus atrophy) were highly correlated to the group with clinical symptoms and indicate an extremely unsatisfying long-term mental prognosis. CT-scanning is a valuable tool for the examination of clearing children with infantile spasms. (authors)

  10. Evaluation of pulmonary congestion by computed tomography

    International Nuclear Information System (INIS)

    Morooka, Nobuhiro; Yamamoto, Hironori; Yoshida, Hideo; Watanabe, Shigeru; Nakamura, Mamoru

    1980-01-01

    Pulmonary congestion and pulmonary water distribution of lung fields were evaluated by computed tomography (CT) in 31 patients with congestive heart failure and 19 normal subjects in the supine position. In normal subjects, no difference was noted in the CT value between levels of intercostal spaces as well as between right and left lung fields. CT values were greater in posterior lung fields than in anterior lung fields. A significant increase of CT values at both anterior and posterior lung fields was shown in patients with congestive heart failure compared to normal subjects. In congestive heart failure, pulmonary CT values were correlated with various clinical parameters in the order of chest X-ray findings, NYHA functional classification, venous pressure, right heart catheter findings and circulation time. CT values were decreased with the improvement of parameters by medical treatment. Thus, the increase of pulmonary CT values in patients with congestive heart failure indicated the increase of pulmonary blood content and pulmonary tissue edema in a unit volume. This method was particularly useful for the evaluation of pulmonary congestion and pulmonary water distribution. (author)

  11. Ruptured ectopic pregnancy diagnosed with computed tomography

    International Nuclear Information System (INIS)

    Michalak, Maciej; Żurada, Anna; Biernacki, Maciej; Zygmunt, Kozielec

    2010-01-01

    The rupture of ectopic pregnancy (EP) still remains the primary and direct cause of death in the first trimester of pregnancy. Ultrasonography is known to be a modality of choice in EP diagnostics. We found a severe discrepancy between the frequency of ectopic pregnancies (EP) and the number of available computed tomography (CT) examinations. A 29-year-old woman was admitted to the emergency department with a history of abdominal pain, nausea, vomiting and collapse. Sonographic findings of a suspected EP were unclear. Moreover, not all features of intrauterine pregnancy were present. Due to the patient’s life-threatening condition, an emergency multi-slice CT with MPR and VRT reconstructions was performed, revealing symptoms of a ruptured EP. In the right adnexal area, a well-vascularized, solid-cystic abnormal mass lesion was found. Intraperitoneal hemorrhage was confirmed intraoperatively, and the right fallopian tube with a tubal EP was resected. In the surgery in situ, as well as in the pathological examination of the tumor mass, a human embryo of approximately 1.5 cm in length (beginning of the 8 th week of gestation) was found. Although ultrasonography still remains the first-line imaging examination in EP diagnostics, sometimes the findings of suspected EPs are unclear and not sufficient. The rupture of EP, with serious bleeding and symptoms of shock, may require an emergent pelvic and abdominal CT inspection. A clear correlation was found between the macroscopic CT images and the intraoperatively sampled material

  12. Dynamic X-ray computed tomography

    International Nuclear Information System (INIS)

    Grangeat, P.

    2003-01-01

    Paper Dynamic computed tomography (CT) imaging aims at reconstructing image sequences where the dynamic nature of the living human body is of primary interest. Main concerned applications are image-guided interventional procedures, functional studies and cardiac imaging. The introduction of ultra-fast rotating gantries along with multi-row detectors and in near future area detectors allows a huge progress toward the imaging of moving organs with low-contrast resolution. This paper gives an overview of the different concepts used in dynamic CT. A new reconstruction algorithm based on a voxel-specific dynamic evolution compensation is also presented. It provides four-dimensional image sequences with accurate spatio-temporal information, where each frame is reconstructed using a long-scan acquisition mode on several half-turns. In the same time, this technique permits to reduce the dose delivered per rotation while keeping the same signal to noise ratio for every frame using an adaptive motion-compensated temporal averaging. Results are illustrated on simulated data. (authors)

  13. Computed tomography of lacrimal fossa tumors

    International Nuclear Information System (INIS)

    Park, Chan Sup; Kim, Young Goo; Chang, Kee Hyun

    1985-01-01

    The lacrimal fossa can be involved by a wide spectrum of orbital pathology. The correct diagnosis is important to avoid unnecessary procedure and to do appropriate management. 14 patients with mass lesions in the lacrimal fossa were evaluated with computed tomography (CT) and clinical findings. The results were as follows: 1. Final diagnosis of 14 cases with lacrimal fossa tumors was pleomorphic adenoma in 3 cases, adenoid cystic carcinoma in 1 case, pseudotumor in 5 cases, lymphoma in 2 cases, neurofibroma in 1 case, chloroma in 1 case and metastatic adenocarcinoma in 1 case. 2. The duration of symptoms of pleomorphic adenoma was more than 1 year and characteristic CT findings were globular masses with pressure erosion of the adjacent bone. Patient with adenoid cystic carcinoma had a short history of symptoms. CT showed a fusiform mass but intracranial extension with frank destruction of sphenoid bone. 3. Patients with pseudotumor and lymphoma had symptoms for less than 1 year. The CT findings were ill-defined infiltrative patterns with scleral thickening and the differential diagnosis of them was difficult. 4. The margins of neurofibroma and chloroma were well defined while that of the metastic adenocarcinoma was ill-defined. 5. The degree and the extent of the contrast enhancement gave no benefit in the differential diagnosis of each disease entities and even of the benign and malignant lesions

  14. Computed tomography in acute ischemic stroke

    International Nuclear Information System (INIS)

    Loevblad, Karl-Olof; Baird, Alison E.

    2010-01-01

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  15. Computed tomography of the breast cancer

    International Nuclear Information System (INIS)

    Chung, Soo Young; Lee, Yul; Bae, Sang Hoon; Yoon, Jong Sup; Lee, Ki Chu

    1985-01-01

    The indication of computed tomography for the breast lesion are 1) Unusually extensive or small breast caused technical difficulties in performing mammograms. 2) Questionable mammographic findings, especially in dense proliferative breast parenchyme. 3) Microcancer. 4) Suspicious regional lymph node enlargement or invasive of the chest wall by breast cancer. The diagnosis of breast CT in breast cancer is based on pathologic anatomic changes and characteristic increase of mean CT No. of lesion following contrast enhancement. Authors analysed CT of the 34 patients who were clinically suspected breast cancer, and compared with mammography. The results are as follows: 1. Pathological diagnosis of 34 cases were 27 cases of breast cancer, 4 cases of fibrocystic disease, 2 cases of fibroadenoma, and 1 case of intraductal papilloma. The diagnostic accuracy of CT in 27 breast cancer was 93% (25 cases) and mammography 71% (19 case). 2. Correct diagnosis of CT in 7 benign breast disease is in 5 cases and mammography in 5 cases. 3. The most important finding of CT in breast cancer is characteristic increase of CT No. of lesion following contrast enhancement (200 ml, 65%): over average 50 HU in 19 cases of 27 breast cancers, 30-50 HU in a 6 cases, 20-30 HU in 2 cases with tumor necrosis. 4. Computed with mammography, other more valuable CT findings of breast cancer are axillary lymph node enlargement and adjacentic pectoral muscle invasion. 5. In conclusion, breast CT is considered as valuable diagnostic tool in evaluation of breast cancer, but not of benign breast disease

  16. Computed tomography of the breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Lee, Yul; Bae, Sang Hoon; Yoon, Jong Sup; Lee, Ki Chu [Hallym University Medical Center, Seoul (Korea, Republic of)

    1985-12-15

    The indication of computed tomography for the breast lesion are 1) Unusually extensive or small breast caused technical difficulties in performing mammograms. 2) Questionable mammographic findings, especially in dense proliferative breast parenchyme. 3) Microcancer. 4) Suspicious regional lymph node enlargement or invasive of the chest wall by breast cancer. The diagnosis of breast CT in breast cancer is based on pathologic anatomic changes and characteristic increase of mean CT No. of lesion following contrast enhancement. Authors analysed CT of the 34 patients who were clinically suspected breast cancer, and compared with mammography. The results are as follows: 1. Pathological diagnosis of 34 cases were 27 cases of breast cancer, 4 cases of fibrocystic disease, 2 cases of fibroadenoma, and 1 case of intraductal papilloma. The diagnostic accuracy of CT in 27 breast cancer was 93% (25 cases) and mammography 71% (19 case). 2. Correct diagnosis of CT in 7 benign breast disease is in 5 cases and mammography in 5 cases. 3. The most important finding of CT in breast cancer is characteristic increase of CT No. of lesion following contrast enhancement (200 ml, 65%): over average 50 HU in 19 cases of 27 breast cancers, 30-50 HU in a 6 cases, 20-30 HU in 2 cases with tumor necrosis. 4. Computed with mammography, other more valuable CT findings of breast cancer are axillary lymph node enlargement and adjacentic pectoral muscle invasion. 5. In conclusion, breast CT is considered as valuable diagnostic tool in evaluation of breast cancer, but not of benign breast disease.

  17. Mobile computing initiatives within pharmacy education.

    Science.gov (United States)

    Cain, Jeff; Bird, Eleanora R; Jones, Mikael

    2008-08-15

    To identify mobile computing initiatives within pharmacy education, including how devices are obtained, supported, and utilized within the curriculum. An 18-item questionnaire was developed and delivered to academic affairs deans (or closest equivalent) of 98 colleges and schools of pharmacy. Fifty-four colleges and schools completed the questionnaire for a 55% completion rate. Thirteen of those schools have implemented mobile computing requirements for students. Twenty schools reported they were likely to formally consider implementing a mobile computing initiative within 5 years. Numerous models of mobile computing initiatives exist in terms of device obtainment, technical support, infrastructure, and utilization within the curriculum. Responders identified flexibility in teaching and learning as the most positive aspect of the initiatives and computer-aided distraction as the most negative, Numerous factors should be taken into consideration when deciding if and how a mobile computing requirement should be implemented.

  18. Computer stress study of bone with computed tomography

    International Nuclear Information System (INIS)

    Linden, M.J.; Marom, S.A.; Linden, C.N.

    1986-01-01

    A computer processing tool has been developed which, together with a finite element program, determines the stress-deformation pattern in a long bone, utilizing Computed Tomography (CT) data files for the geometry and radiographic density information. The geometry, together with mechanical properties and boundary conditions: loads and displacements, comprise the input of the Finite element (FE) computer program. The output of the program is the stresses and deformations in the bone. The processor is capable of developing an accurate three-dimensional finite element model from a scanned human long bone due to the CT high pixel resolution and the local mechanical properties determined from the radiographic densities of the scanned bone. The processor, together with the finite element program, serves first as an analysis tool towards improved understanding of bone function and remodelling. In this first stage, actual long bones may be scanned and analyzed under applied loads and displacements, determined from existing gait analyses. The stress-deformation patterns thus obtained may be used for studying the biomechanical behavior of particular long bones such as bones with implants and with osteoporosis. As a second stage, this processor may serve as a diagnostic tool for analyzing the biomechanical response of a specific patient's long long bone under applied loading by utilizing a CT data file of the specific bone as an input to the processor with the FE program

  19. Computer tomography in complex diagnosis of laryngeal cancer

    International Nuclear Information System (INIS)

    Savin, A.A.

    1999-01-01

    To specify the role of computer tomography in the diagnosis of malignant of the larynx. Forty-two patients with suspected laryngeal tumors were examined: 38 men and 4 women aged 41-68 years. X-ray examinations included traditional immediate tomography of the larynx. Main X-ray and computer tomographic symptoms of laryngeal tumors of different localizations are described. It is shown that the use of computer tomography in complex diagnosis of laryngeal cancer permits an objective assessment of the tumor, its structure and dissemination, and of the regional lymph nodes [ru

  20. Diffuse abnormalities of the trachea: computed tomography findings

    International Nuclear Information System (INIS)

    Marchiori, Edson; Araujo Neto, Cesar de

    2008-01-01

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  1. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  2. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  3. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  4. Computed tomography of the llama head: technique and normal anatomy

    International Nuclear Information System (INIS)

    Hathcock, J.T.; Pugh, D.G.; Cartee, R.E.; Hammond, L.

    1996-01-01

    Computed tomography was performed on the head of 6 normal adult llamas. The animals were under general anesthesia and positioned in dorsal recumbency on the scanning table. The area scanned was from the external occipital protuberance to the rostral portion of the nasal passage, and the images are presented in both a bone window and a soft tissue window to allow evaluation and identification of the anatomy of the head. Computed tomography of the llama head can be accomplished by most computed tomography scanners utilizing a technique similar to that used in small animals with minor modification of the scanning table

  5. Diagnosis of hoof diseases in horses using computed tomography

    International Nuclear Information System (INIS)

    Kovac, M.; Nowak, M.; Kaufels, N.; Tambur, Z.

    2002-01-01

    This study describes findings of computed tomography investigations at the Bergische Equine Clinic (Bergische Tierklinik), Germany, of 39 horses with hoof diseases. The most frequently findings were the navicular syndrome (eight horses), laminitis (seven horses), keratnoma (six horses) and ossification of collateral cartilages in the distal phalanx (four horses). The special value of the computed tomography is in evaluating the size and courses fracture/fissure of the navicular and koffin bones, which were diagnose in five horses. In four of horses no pathologic changes of the hoof were determined by computed tomography

  6. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  7. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  8. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  9. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  10. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  11. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  12. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  13. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  14. Computed tomography in Duchenne type muscular dystrophy

    International Nuclear Information System (INIS)

    Kawai, Mitsuru; Kunimoto, Masanari; Motoyoshi, Yasufumi; Kuwata, Takashi; Nakano, Imaharu

    1985-01-01

    The computed tomography (CT) scan was performed on 91 Duchenne type muscular dystrophy (DMD) patients on the following four levels; (1) at the level of L3 vertebra, (2) 2-3cm above the symphysis pubica, (3) midposition of the thigh, (4) largest-diameter section of the lower leg. The CT of muscles common to most of the DMD patients were as follows: 1. Muscle atrophy: Muscle atrophy was shown as a reduction in the cross-sectional area of the muscles. Very mild muscle atrophy could be detected either by the clearly identified muscle border or by scattered low-density areas of so-called ''moth-eaten'' appearance within muscles. 2. Fat infiltration: The decrease in radio-density of muscles was interpreted as infiltration of fatty tissue. This type of density change was further classified into diffuse, streaked, cobblestone and salt-and-pepper patterns according to the spacial distribution of low-density areas. 3. Selectivity pattern: As the chronological sequence of DMD muscle degeneration is usually different among individual muscles, it may be seen, in some stages, that some of the synergistic muscles are still only slightly involved, while the others are quite severely atrophied with evident fat infiltration. In certain stages of the disease, most of the patients show relative preservation of particular muscles although they assumed a rounded shape. The most resistent muscle was musculus gracilis, followed by the musculus sartorius, musculus semitendinosus (and/or musculus semimembranosus) in that order. According to the severity of the CT changes, 86 of the 91 patients were classed into five stages from A1 to A5. Morphological stages (A1-A5) were well correlated to the functional disability stages by Ueda with a correlation factor of r=0.88. (J.P.N.)

  15. Characterization of HPGe detectors using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hedman, A., E-mail: Angelica.Hedman@foi.se [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Bahar Gogani, J.; Granström, M. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Johansson, L.; Andersson, J.S. [Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Ramebäck, H. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-41296 Göteborg (Sweden)

    2015-06-11

    Computed Tomography (CT) high-resolution imaging have been used to investigate if there is a significant change in the crystal-to-window distance, i.e. the air gap thickness, in a small n-type detector cooled to 77 K, and in a medium sized p-type HPGe detector when cooled to 100 K. The findings were compared to detector dimension data made available by the manufacturer. The air gap thickness increased by (0.38±0.07) mm for the n-type detector and by (0.40±0.15) mm for the p-type detector when the detectors were cooled to 77 resp. 100 K compared to at room temperature. Monte Carlo calculations indicate that these differences have a significant impact on the efficiency in close geometries (<5 cm). In the energy range of 40–700 keV with a source placed directly on endcap, the change in detector efficiency with temperature is 1.9–2.9% for the n-type detector and 0.3–2.1% for the p-type detector. The measured air gap thickness when cooling the detector was 1.1 mm thicker than manufacturer data for the n-type detector and 0.2 mm thicker for the p-type detector. In the energy range of 40–700 keV and with a source on endcap, this result in a change in detector efficiency of 5.2–7.1% for the n-type detector and 0.2–1.0% for the p-type detector, i.e. the detector efficiency is overestimated using data available by the manufacturer.

  16. Evaluation of computed tomography of intraventricular hemorrhage

    International Nuclear Information System (INIS)

    Yoo, Seon Young; Lee, Young Sik; Suh, Jeong Soo; Rhee, Chung Sik; Kim, Hee Seup

    1983-01-01

    Prior to the introduction of computed tomography, the clinical and radiological diagnosis of the intraventricular hemorrhage in living patients was difficult. C.T. scanning is an invaluable investigation providing the rapid and noninvasive diagnosis of intracerebral and intraventricular hemorrhage. It reliably demonstrates the presence and distribution of fresh blood within the ventricular system. C.T. is also useful as a surgical guidance and in the evaluation of fate of the hematoma by easily performable follow-up studies. We reviewed 31 cases of intraventricular hemorrhage in C.T. in the department of radiology of Ewha Womans University Hospital during the period from August, 1982 to August, 1983. The results were as follows: 1. The most patients were encountered in the 5th decade and the male to female ratio was 1.2 : 1. 2. Hypertension was the main cause of the intraventricular hemorrhage; 18 out of 31 patients. Remaining 13 patients were caused by hypoxia, aneurysm, Moya Moya disease, coagulation defect, trauma and undetermined etiology. 3. 18 out of 31 patients showed hemorrhage in the lateral ventricles only and all ventricles in 10 patients. 4. 28 out of 31 patients showed associated with intracranial hematoma; Those were intracerebral hematomas in 16 patients, intracerebral hematoma with subarachnoid hemorrhage in 4 patients and extracerebral hematoma in 2 patients. 5. Outcome was assessed using the Glasgow scale. According to them, the total mortality rates was 54.8%, however, 32.3% of patients returned to normal or minor disability. Patients, who had hypertension and marked degree of hemorrhage in the ventricular systems had a poor outcome. Patients with only ventricular hemorrhage had better outcome than associated intracranial hematoma. 6. 16 out of 31 patients were treated by surgical methods and 15 out of 31 patients by conservative methods. 75% of patients were died in conservative treatment. 7. Conclusively, causes, degree of intraventricular

  17. Measurement of kidney by computed tomography

    International Nuclear Information System (INIS)

    Hamada, Tatsumi; Nakagawa, Kenichi; Tamura, Kenji; Yoshida, Akio; Fujii, Koichi

    1983-01-01

    Several measurements of normal kidney in vivo were obtained from computed tomography and were correlated with age, sex and body dimensions. Forty four males and 21 females without a history of renal disease were studied. 1. Angle between renal coronal section and body frontal (degree): The mean value (+- SD) of the angle was 44.0 +- 11.1 for right kidney and 42.3 +- 11.2 for left, with a low correlation coefficient. The angle had no significant correlation with age nor sex. 2. The largest width of kidney (cm): The mean value of the width was 4.6 +- 0.6 for male right kidney, 5.1 +- 0.6 for male left, 4.6 +- 0.7 for female right and 4.7 +- 1.0 for female left. The values correlated with age under 40 positively and over 40 negatively. 3. Renal volume (cm 3 ): Renal volume was calculated by adding together the area measurements obtained from successive 1 cm thick scans, excluding renal sinus. The mean volume was 107 +- 27 for male right kidney, 114 +- 24 for male left, 101 +- 33 for female right and 111 +- 41 for female left. The correlation coefficient of right versus left renal volume was significantly high. Total renal volume, i. e. left + right renal volume, had significant negative correlation with age over 40. 4. CT numbers of kidney: Average value of right kidney was 31.4 +- 6.0 and that of left was 30.7 +- 5.9. Though the correlation coefficient between right and left was nearly 1, no significant correlation was found with other values. (author)

  18. Ultrasonic and computed tomography in radiotherapy planning - a comparison

    International Nuclear Information System (INIS)

    Schertel, L.

    1980-01-01

    The precondition of any radiotherapy is radiation planning. This must be done individually for every patient and must be applicable for any region of the body. Modern irradiation planning requires pictures of the body parts concerned; these can be made by means of the ultrasonic method and computed tomography. This comparative investigation leads to the result (see fig. 4 and 5) that computed tomographic body part pictures should be preferred to those made sonographically. The opinion of Huenig and Co. [8] that ultrasonic tomography will soon lose some of its importance within irradiation planning once computed tomography is introduced could be confirmed by the latest developments. The authors can confirm this also out of their own experience and agree with Winkel and Hermann [23] that computed tomography cannot be done without any more irradiation planning. (orig.) [de

  19. X-ray Computed Tomography of Ultralightweight Metals

    National Research Council Canada - National Science Library

    Winter, John

    2001-01-01

    .... To date, the imaging capabilities of x-ray computed tomography have not been generally employed to nondestructively examine the internal structure of the products formed by these various processes...

  20. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  1. Staging with computed tomography of patients with colon cancer

    DEFF Research Database (Denmark)

    Malmstrom, M. L.; Brisling, S.; Klausen, T. W.

    2018-01-01

    Purpose Accurate staging of colonic cancer is important for patient stratification. We aimed to correlate the diagnostic accuracy of preoperative computed tomography (CT) with final histopathology as reference standard. Methods Data was collected retrospectively on 615 consecutive patients operated...

  2. Computed tomography of the head in neurological examination of children

    International Nuclear Information System (INIS)

    Baeckman, E.; Egg-Olofsson, O.; Raadberg, C.

    1980-01-01

    A total of 247 children from the departments of pediatrics and neurosurgery were examined with computed tomography of the head during a two year period in 1977-78. Pathological changes were demonstrated in 79 per cent. Supplementary neuro-radiological examination - angiography and encephalography - was necessary in 17 per cent. Computed tomography together with the clinical assessment frequently suffices for final diagnosis. Computed tomography greatly reduces the need for previously used neurological examinations including skull radiography. Complications may ensure because of over-sensitivity to intravenously administered contrast medium in connection with anesthesia, and the radiation dose particularly to the crystalline lens of the eye must be taken into account. Computed tomography should therefore be used only on strict indications after careful scrutiny of the case history and the status. (author)

  3. Evaluation of resectability of renal cell carcinoma by computed tomography

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Matsumoto, Kunihiko; Tatezawa, Takashi; Kikuchi, Yoichi; Akisada, Masahiro; Kitagawa, Ryuichi

    1982-01-01

    Renal cell carcinoma is one of the unique neoplasm which is characterized by disappearing of the metastatic tumors after removal of the primary lesion. Angiography has been performed to evaluate the resectability of the primary tumor by nephrectomy in the past. With the use of computed tomography, detailed evaluation of the retroperitoneal structures is now possible. We have evaluated the resectability of renal cell tumor by computed tomography and compared the results with the angiographic findings and operative findings. Computed tomography is very accurate in determining the extent of the tumor especially in evaluation of tumor and the Gerota's fascia, which is essential to determine the resectability of the tumor. Informations about lymph node metastasis and invasion to the renal veins or inferior vena cava are also obtained.FIn most of the cases, angiography can be spared if computed tomography is properly performed. (author)

  4. X-ray Computed Tomography Image Quality Indicator (IQI) Development

    Data.gov (United States)

    National Aeronautics and Space Administration — Phase one of the program is to identify suitable x-ray Computed Tomography (CT) Image Quality Indicator (IQI) design(s) that can be used to adequately capture CT...

  5. Computed tomography and childhood seizure disorder in Ibadan ...

    African Journals Online (AJOL)

    Computed tomography and childhood seizure disorder in Ibadan. ... neuroimaging, it offers an opportunity to investigate structural lesions as a cause of seizures ... The presence of neurologic deficit increased the yield of abnormal CT features.

  6. Use of computed tomography to diagnose sinusitis in a goat

    International Nuclear Information System (INIS)

    Barrington, G.M.; Tucker, R.L.

    1996-01-01

    Radiographic examination proved incapable of determining the extent and severity of chronic sinusitis in a goat. Computed tomography was subsequently used to clearly define the nature and extent of the lesion

  7. Use of computed tomography in nondestructive testing of polymeric materials

    International Nuclear Information System (INIS)

    Persson, S.; Oestman, E.

    1985-01-01

    Computed tomography has been used to detect imperfections and to measure cross-link density gradients in polymeric products, such as airplane tires, rubber shock absorbers, and filament-wound high-pressure tanks

  8. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  9. Comparison of Tissue Density in Hounsfield Units in Computed Tomography and Cone Beam Computed Tomography.

    Science.gov (United States)

    Varshowsaz, Masoud; Goorang, Sepideh; Ehsani, Sara; Azizi, Zeynab; Rahimian, Sepideh

    2016-03-01

    Bone quality and quantity assessment is one of the most important steps in implant treatment planning. Different methods such as computed tomography (CT) and recently suggested cone beam computed tomography (CBCT) with lower radiation dose and less time and cost are used for bone density assessment. This in vitro study aimed to compare the tissue density values in Hounsfield units (HUs) in CBCT and CT scans of different tissue phantoms with two different thicknesses, two different image acquisition settings and in three locations in the phantoms. Four different tissue phantoms namely hard tissue, soft tissue, air and water were scanned by three different CBCT and a CT system in two thicknesses (full and half) and two image acquisition settings (high and low kVp and mA). The images were analyzed at three sites (middle, periphery and intermediate) using eFilm software. The difference in density values was analyzed by ANOVA and correction coefficient test (P<0.05). There was a significant difference between density values in CBCT and CT scans in most situations, and CBCT values were not similar to CT values in any of the phantoms in different thicknesses and acquisition parameters or the three different sites. The correction coefficients confirmed the results. CBCT is not reliable for tissue density assessment. The results were not affected by changes in thickness, acquisition parameters or locations.

  10. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. Pulmonary artery aneurysm in Bechcet's disease: helical computed tomography study

    International Nuclear Information System (INIS)

    Munoz, J.; Caballero, P.; Olivera, M. J.; Cajal, M. L.; Caniego, J. L.

    2000-01-01

    Behcet's disease is a vasculitis of unknown etiology that affects arteries and veins of different sizes and can be associated with pulmonary artery aneurysms. We report the case of a patient with Behcet's disease and a pulmonary artery aneurysm who was studied by means of plain chest X ray, helical computed tomography and pulmonary arteriography. Helical computed tomography is a reliable technique for the diagnosis and follow-up of these patients. (Author) 9 refs

  12. Pediatrics patient in computed tomography: risk awareness among medical staff

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Kosutic, D.; Lazarevic, Dj.

    2009-01-01

    In this paper the results of investigation about risk awareness in pediatrics computed tomography among medical staff are presented. Questionnaires were distributed along seven hospitals, 84 people were enrolled in this investigation. The results showed awareness of the potential risks associated with ionizing radiation in computed tomography. However, there is still widespread underestimation of relative doses and risks in case of pediatric patients. (author) [sr

  13. Advances in equine computed tomography and use of contrast media.

    Science.gov (United States)

    Puchalski, Sarah M

    2012-12-01

    Advances in equine computed tomography have been made as a result of improvements in software and hardware and an increasing body of knowledge. Contrast media can be administered intravascularly or intrathecally. Contrast media is useful to differentiate between tissues of similar density. Equine computed tomography can be used for many different clinical conditions, including lameness diagnosis, fracture identification and characterization, preoperative planning, and characterization of skull diseases. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Computed tomography in orbital fractures and optic nerve trauma

    International Nuclear Information System (INIS)

    Dietrich, U.; Sievers, K.; Feldges, A.; Nau, H.E.

    1990-01-01

    Ten patients with orbital fractures and optic nerve trauma are reported. Fractures of the optic canal could be demonstrated by computed tomography in six cases and fractures of the orbital apex in another three cases. Surgical decompression of the optic canal was performed in seven cases. Computed tomography enhanced decision for surgery in cases of intraorbital haematoma with exophthalmus and narrowing of the canal by bony fragments, especially in those patients presenting with incomplete or progressive visual disturbance. (orig.) [de

  15. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  16. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Vallejos, J.; Capunay, Carlos M.; Deviggiano, A.; Carrascosa, Jorge M.

    2007-01-01

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine [es

  17. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-01-01

    fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a

  18. Temporal bone trauma and complications: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Ana Maria Doffemond; Gaiotti, Juliana Oggioni; Couto, Caroline Laurita Batista; Gomes, Natalia Delage; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho, E-mail: anadoffemond@yahoo.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unit of Radiology and Imaging Diagnosis

    2013-03-15

    Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others. (author)

  19. Temporal bone trauma and complications: computed tomography findings

    International Nuclear Information System (INIS)

    Costa, Ana Maria Doffemond; Gaiotti, Juliana Oggioni; Couto, Caroline Laurita Batista; Gomes, Natalia Delage; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho

    2013-01-01

    Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others. (author)

  20. Evaluation of computer tomography in cerebro-vascular disease (Strokes)

    International Nuclear Information System (INIS)

    Lee, Young Sik; Baek, Seung Yon; Rhee, Chung Sik; Kim, Hee Seup

    1984-01-01

    Most of cerebrovascular disease are composed of vascular occulusive changes and hemorrhage. Now a day, the computed tomography is the best way for evaluation of cerebrovascular disease including detection of nature, location, and associated changes. This study includes evaluation of computed tomography of 70 patients with cerebrovascular disease during the period of 10 months from April. 1983 to Feb. 1984 in Department of Radiology, Ewha Womans University Hospital. The results were as follows: 1. Age distribution of the total 70 patients was broad ranging from 25 years to 79 years. 78.6% of patients were over the age of 50. The male and female sex ratio was 1.4:1. 2. 4 out of 70 patients were normal and 66 patients revealed abnormal on C.T. findings; those were intracranial hemorrhage (28 patients), cerebral infarction (34 patients) and brain atrophy (4 patients). 3. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (28 cases), and next was basal ganglia (2 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. 4. In cases of intracranial hemorrhage, the basal ganglia was most common site of lesion (15 cases). The next common site was cerebral hemisphere (9 cases). 6 patients of all intracranial hemorrhage were combined with intraventricular hemorrhage. Ratio of right and left was 2:3. 5. In patients with motor weakness or hemiparesis, more common findings on CT scan were cerebral infarction. In case with hemiplegia, more common CT findings were intracerebral hemorrhage. 6. Of the 40 cases thought to be cerebral infarction initially by clinical findings and spinal tap. 8 cases (20.0%) were proved to be cerebral hemorrhage by the CT scan. However, of the 22 cases thought to be cerebral hemorrhage, initially, only two cases (9.0%) were cerebral infarction

  1. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  2. Computed tomography of the orbital tumors

    International Nuclear Information System (INIS)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck; Ahn, Byeong Yeob

    1987-01-01

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  3. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  4. An industrial demonstration of computer assisted tomography

    International Nuclear Information System (INIS)

    Lupton, L.R.

    1985-09-01

    Computerized tomography (CT) is a nondestructive testing technique for generating quantitative density (linear attenuation coefficient) maps of a cross section through an object. By using a series of parallel tomographic images taken at different elevations, a three-dimensional (3-D) map of the object can be obtained. To demonstrate the power of tomography, a 3-D region of a motorcycle carburetor has been imaged using twenty-four parallel two-dimensional images. From these data, new images in planes orthogonal to the original planes have been generated, thereby improving the user's ability to visualize the position of components within the carburetor. The data have also been used to demonstrate the relationship between tomography and radiography

  5. Spectrum of single photon emission computed tomography/computed tomography findings in patients with parathyroid adenomas.

    Science.gov (United States)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Bhadada, Sanjay

    2011-01-01

    Primary hyperparathyroidism results from excessive parathyroid hormone secretion. Approximately 85% of all cases of primary hyperparathyroidism are caused by a single parathyroid adenoma; 10-15% of the cases are caused by parathyroid hyperplasia. Parathyroid carcinoma accounts for approximately 3-4% of cases of primary disease. Technetium-99m-sestamibi (MIBI), the current scintigraphic procedure of choice for preoperative parathyroid localization, can be performed in various ways. The "single-isotope, double-phase technique" is based on the fact that MIBI washes out more rapidly from the thyroid than from abnormal parathyroid tissue. However, not all parathyroid lesions retain MIBI and not all thyroid tissue washes out quickly, and subtraction imaging is helpful. Single photon emission computed tomography (SPECT) provides information for localizing parathyroid lesions, differentiating thyroid from parathyroid lesions, and detecting and localizing ectopic parathyroid lesions. Addition of CT with SPECT improves the sensitivity. This pictorial assay demonstrates various SPECT/CT patterns observed in parathyroid scintigraphy.

  6. Tangential scanning of hardwood logs: developing an industrial computer tomography scanner

    Science.gov (United States)

    Nand K. Gupta; Daniel L. Schmoldt; Bruce Isaacson

    1999-01-01

    It is generally believed that noninvasive scanning of hardwood logs such as computer tomography (CT) scanning prior to initial breakdown will greatly improve the processing of logs into lumber. This belief, however, has not translated into rapid development and widespread installation of industrial CT scanners for log processing. The roadblock has been more operational...

  7. Communication between the right and circumflex coronary arteries discovered incidentally by multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Se Hwan; Kim, Eui Jong; Woo, Jong Shin; Kim, Soo Joong; Youn, Hyo Chul; Oh, Joo Hyeong [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2016-09-15

    Intercoronary communication is a rare congenital coronary anomaly. We present a case of a 48-year-old man with an incidentally discovered communication between the right and circumflex coronary arteries, who was admitted with chest tightness and exertional dyspnea. The initial diagnosis was made using electrocardiogram-gated multidetector computed tomography.

  8. Computed tomography of thymic abnormalities: review of 10 patients

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Brito Pacheco, E.M. de; Cazerta, N.M.G.; Silva, M.J.G. da

    1990-01-01

    Chest radiographs and computed tomographic scans of the mediastinum were correlated with pathologic findings of the thymus following thymectomy in 10 patients with thymic disease. There were five patients with thymoma, four with thymic hiperplasia and one with benign thymic cyst. Computed tomography shoud be the imaging method of choice following plain chest radiographs when a suspect thymic abnormality requires further evaluation. Recognition of variations in the normal location, size, shape and density of the thymus prevents misinterpretation as abnormal mediastinal mass. Furthermore, knowledge of the normal computed tomography appearance has proved helpful in evaluating thymic abnormalities. (author)

  9. Dose estimation for paediatric cranial computed tomography

    International Nuclear Information System (INIS)

    Curci Daros, K.A.; Bitelli Medeiros, R.; Curci Daros, K.A.; Oliveira Echeimberg, J. de

    2006-01-01

    In the last ten years, the number of paediatric computed tomography (CT) scans have increased worldwide, contributing to higher population radiation dose. Technique diversification in paediatrics and different CT equipment technologies have led to various exposure levels complicating precise evaluation of doses and operational conditions necessary for good quality images. The objective of this study was to establish a quantitative relationship between absorbed dose and cranial region in children up to 6 years old undergoing CT exams. Methods: X-ray was measured on the cranial surface of 64 patients undergoing CT using thermoluminescent (T.L.) dosimeters. Forty T.L.D.100 thermoluminescent dosimeters (T.L.D.) were evenly distributed on each patients skin surface along the sagittal axis. Measurements were performed in facial regions exposed to scatter radiation and in the supratentorial and posterior fossa regions, submitted to primary radiation. T.L.D. were calibrated for 120 kV X-ray over the acrylic phantom. T.L. measurements were made with a Harshaw 4000 system. Patient mean T.L. readings were determined for position, pi, of T.L.D. and normalized to the maximum supratentorial reading. From integrating the linear T.L. density function (?) resulting from radiation distribution in each of the three exposed regions, dose fraction was determined in the region of interest, along with total dose under the technical conditions used in that specific exam protocol. For each T.L.D. position along the patient cranium, there were n T.L. measurements with 2% uncertainty due to T.L. reader, and 5% due to thermal treatment of dosimeters. Also, mean T.L. readings and their uncertainties were calculated for each patient at each position, p. Results: Mean linear T.L. density for the region exposed to secondary radiation defined by position, 0.3≤p≤6 cm, was ρ((p)=7.9(4)x10 -2 +7(5)x10 -5 p 4.5(4) cm -1 ; exposed to primary X-ray for the posterior fossa region defined by position

  10. Dose estimation for paediatric cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Curci Daros, K.A.; Bitelli Medeiros, R. [Sao Paulo Univ. Federal (Brazil); Curci Daros, K.A.; Oliveira Echeimberg, J. de [Centro Univ. Sao Camilo, Sao Paulo (Brazil)

    2006-07-01

    In the last ten years, the number of paediatric computed tomography (CT) scans have increased worldwide, contributing to higher population radiation dose. Technique diversification in paediatrics and different CT equipment technologies have led to various exposure levels complicating precise evaluation of doses and operational conditions necessary for good quality images. The objective of this study was to establish a quantitative relationship between absorbed dose and cranial region in children up to 6 years old undergoing CT exams. Methods: X-ray was measured on the cranial surface of 64 patients undergoing CT using thermoluminescent (T.L.) dosimeters. Forty T.L.D.100 thermoluminescent dosimeters (T.L.D.) were evenly distributed on each patients skin surface along the sagittal axis. Measurements were performed in facial regions exposed to scatter radiation and in the supratentorial and posterior fossa regions, submitted to primary radiation. T.L.D. were calibrated for 120 kV X-ray over the acrylic phantom. T.L. measurements were made with a Harshaw 4000 system. Patient mean T.L. readings were determined for position, pi, of T.L.D. and normalized to the maximum supratentorial reading. From integrating the linear T.L. density function (?) resulting from radiation distribution in each of the three exposed regions, dose fraction was determined in the region of interest, along with total dose under the technical conditions used in that specific exam protocol. For each T.L.D. position along the patient cranium, there were n T.L. measurements with 2% uncertainty due to T.L. reader, and 5% due to thermal treatment of dosimeters. Also, mean T.L. readings and their uncertainties were calculated for each patient at each position, p. Results: Mean linear T.L. density for the region exposed to secondary radiation defined by position, 0.3{<=}p{<=}6 cm, was {rho}((p)=7.9(4)x10{sup -2}+7(5)x10{sup -5}p{sup 4.5(4)} cm{sup -1}; exposed to primary X-ray for the posterior fossa

  11. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  12. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    International Nuclear Information System (INIS)

    Macedo, Clarissa Aguiar de; Baena, Marcos Eduardo da Silva; Uezumi, Kiyomi Kato; Castro, Claudio Campi de; Lucarelli, Claudio Luiz; Cerri, Giovanni Guido

    2008-01-01

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  13. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  14. Lung Hot Spot Without Corresponding Computed Tomography Abnormality on Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Artifactual or Real, Iatrogenic or Pathologic?

    Science.gov (United States)

    Liu, Yiyan

    Focal lung uptake without corresponding lesions or abnormalities on computed tomography (CT) scan poses a dilemma in the interpretation of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). A limited number of case reports have previously suggested an artifactual or iatrogenic nature of the uptake. In the present study, 8 relevant cases were included within a retrospective search of the database. Medical records were reviewed for follow-up radiological and pathologic information. In 7 of 8 cases with focal increased FDG uptake but no corresponding lesions or abnormalities on CT scan, the lung hot spots were artifactual or iatrogenic upon follow-up diagnostic chest CT or repeated PET/CT or both the scans. Microemboli were most likely a potential cause of the pulmonary uptake, with or without partial paravenous injection. One case in the series had a real pulmonary lesion demonstrated on follow-up PET/CT scans and on surgical pathology, although the initial integrated CT and follow-up diagnostic chest CT scans revealed negative findings to demonstrate pulmonary abnormalities corresponding to the hot spot on the PET scan. In conclusion, the finding of a lung hot spot in the absence of anatomical abnormality on FDG PET/CT was most likely artifactual or iatrogenic, but it might also represent a real pulmonary lesion. Nonvisualization of anatomical abnormality could be because of its small size and position directly overlying a segmental vessel. Further image follow-up is necessary and important to clarify the nature of the uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  16. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  17. Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma.

    Science.gov (United States)

    Schillaci, Orazio

    2006-10-01

    In nuclear oncology, despite the fast-growing diffusion of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET), single-photon emission computed tomography (SPECT) studies can still play an useful clinical role in several applications. The main limitation of SPECT imaging with tumor-seeking agents is the lack of the structural delineation of the pathologic processes they detect; this drawback sometimes renders SPECT interpretation difficult and can diminish its diagnostic accuracy. Fusion with morphological studies can overcome this limitation by giving an anatomical map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT images proved to be time-consuming and impractical for routine use. The recent development of dual-modality integrated imaging systems that provide functional (SPECT) and anatomical (CT) images in the same scanning session, with the acquired images coregistered by means of the hardware, has opened a new era in this field. The first reports indicate that SPECT/CT is very useful in cancer imaging because it is able to provide further information of clinical value in several cases. In SPECT, studies of lung cancer and malignant lymphomas using different radiopharmaceutical, hybrid images are of value in providing the correct localization of tumor sites, with a precise detection of the involved organs, and the definition of their functional status, and in allowing the exclusion of disease in sites of physiologic tracer uptake. Therefore, in lung cancer and lymphomas, hybrid SPECT/CT can play a role in the diagnosis of the primary tumor, in the staging of the disease, in the follow-up, in the monitoring of therapy, in the detection of recurrence, and in dosimetric estimations for target radionuclide therapy.

  18. Shielding Calculations for Positron Emission Tomography - Computed Tomography Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baasandorj, Khashbayar [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yang, Jeongseon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Integrated PET-CT has been shown to be more accurate for lesion localization and characterization than PET or CT alone, and the results obtained from PET and CT separately and interpreted side by side or following software based fusion of the PET and CT datasets. At the same time, PET-CT scans can result in high patient and staff doses; therefore, careful site planning and shielding of this imaging modality have become challenging issues in the field. In Mongolia, the introduction of PET-CT facilities is currently being considered in many hospitals. Thus, additional regulatory legislation for nuclear and radiation applications is necessary, for example, in regulating licensee processes and ensuring radiation safety during the operations. This paper aims to determine appropriate PET-CT shielding designs using numerical formulas and computer code. Since presently there are no PET-CT facilities in Mongolia, contact was made with radiological staff at the Nuclear Medicine Center of the National Cancer Center of Mongolia (NCCM) to get information about facilities where the introduction of PET-CT is being considered. Well-designed facilities do not require additional shielding, which should help cut down overall costs related to PET-CT installation. According to the results of this study, building barrier thicknesses of the NCCM building is not sufficient to keep radiation dose within the limits.

  19. Computer tomography in the diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Petkov, D.; Zhelyazkov, S.; Nedelkov, G.

    1983-01-01

    The modern achievements in the clinical study and diagnosis of liver diseases has definitely been associated with the application of whole body computer tomography (CT) in the practice. The diagnostic possibilities of the method come from high contrast and spacial disjunctive capabilities. Visualization of local lesions is associated with their size and the differences in their densitometric compactness from that of the normal parenchyma. The advantages of computer tomography in the diagnosis of liver diseases is discussed. They are associated with the possibilities for densitometric analysis of the pathologic changes, which opens a way for a probable qualitative diagnosis. Diffuse processes in the liver are relative indication for performing computer tomography. Examination under conditions of contrast amplification is indicated in cases when the nature of the lesion has to be specified and a ''negative'' result does not concur with the clinical manifestations. (authors)

  20. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)