WorldWideScience

Sample records for computed radiography procedimentos

  1. Radiological protection procedures for industrial applications of computed radiography; Procedimentos de protecao radiologica em aplicacoes industriais da radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Josilto Oliveira de

    2009-03-15

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  2. Computational radiology in skeletal radiography

    Energy Technology Data Exchange (ETDEWEB)

    Peloschek, Ph.; Nemec, S. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Widhalm, P. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Pattern Recognition and Image Processing Group, Department of Computer Aided Automation, Vienna University of Technology, Wiedner Hauptstrasse 8-10/020, A-1040 Vienna (Austria); Donner, R. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Pattern Recognition and Image Processing Group, Department of Computer Aided Automation, Vienna University of Technology, Wiedner Hauptstrasse 8-10/020, A-1040 Vienna (Austria); Institute for Computer Graphics and Vision, Graz University of Technology, Inffeldgasse 16, A-8010 Graz (Austria); Birngruber, E. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Thodberg, H.H. [Visiana Aps, Sollerodvej 57C, DK-2840 Holte (Denmark); Kainberger, F. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Langs, G. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)], E-mail: georg.langs@meduniwien.ac.at

    2009-11-15

    Recent years have brought rapid developments in computational image analysis in musculo-skeletal radiology. Meanwhile the algorithms have reached a maturity that makes initial clinical use feasible. Applications range from joint space measurement to erosion quantification, and from fracture detection to the assessment of alignment angles. Current results of computational image analysis in radiography are very promising, but some fundamental issues remain to be clarified, among which the definition of the optimal trade off between automatization and operator-dependency, the integration of these tools into clinical work flow and last not least the proof of incremental clinical benefit of these methods.

  3. Standard guide for computed radiography

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide provides general tutorial information regarding the fundamental and physical principles of computed radiography (CR), definitions and terminology required to understand the basic CR process. An introduction to some of the limitations that are typically encountered during the establishment of techniques and basic image processing methods are also provided. This guide does not provide specific techniques or acceptance criteria for specific end-user inspection applications. Information presented within this guide may be useful in conjunction with those standards of 1.2. 1.2 CR techniques for general inspection applications may be found in Practice E2033. Technical qualification attributes for CR systems may be found in Practice E2445. Criteria for classification of CR system technical performance levels may be found in Practice E2446. Reference Images Standards E2422, E2660, and E2669 contain digital reference acceptance illustrations. 1.3 The values stated in SI units are to be regarded as the st...

  4. Image characterization of computed radiography

    Energy Technology Data Exchange (ETDEWEB)

    Candeias, Janaina P.; Saddock, Aline; Oliveira, Davi F.; Lopes, Ricardo T. [Federal University of Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Lab. of Nuclear Instrumentation], E-mail: asaddock@lin.ufrj.br, E-mail: davi@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br

    2007-07-01

    The digital radiographic image became a reality as of the 80's decade. Since then, several works have been developed with the aim of reducing the exposure time to ionizing radiation obtaining in this way an excellent image quality with a minimum exposure. In the Computerized Radiography, the conventional film is substituted for Image Plate (IP) which consists of a radiosensitive layer of phosphor crystals on a polyester backing plate. The unique design makes it reusable and easy to handle. When exposed, the IP accumulates and stores the irradiated radioactive energy. In order to qualify a computerized radiography system it is necessary to evaluate the Image Plate. In this work it was performed a series of experimental procedures with the aim of evaluating the responses characteristics for different plates. For this purpose it was used a computerized radiographic system CR Tower Scanner - GE, with three different types of IPs, all of them manufactured by GE, whose nomenclatures are IPC, IPX and IPS. It was used the Rhythm Acquire and Review programs for image acquisition and treatment, respectively. (author)

  5. REVIEW ARTICLE REVI REVI Computed radiography exposure ...

    African Journals Online (AJOL)

    Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. ... The imaging plate response was characterised in terms of entrance exposure to the plate and the digital ... of the key advantages of this technology; it helps to reduce the retake rate significantly, but at the same time this ...

  6. Computed Radiography Exposure Indices in Mammography | Koen ...

    African Journals Online (AJOL)

    Background. Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. It is therefore important to relate the exposure indicators provided by CR manufacturers to the radiation dose delivered so as to assess the radiation dose delivered to patients directly from the exposure indicators.

  7. Dosimetric evaluation in panoramic and tele-radiography procedures; Avaliacao dosimetrica em procedimentos de radiografia panoramica e teleradiografias

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Georgge Gomes

    2004-07-01

    The present work had as an objective to evaluate the skin surface entrance dose in panoramic and tele radiography procedures in three clinics in Recife - Pernambuco - Brazil, and to contribute with data for the determination of reference levels for super cited extra oral procedures, for this purpose, operational conditions in 3 clinics were evaluated in Recife, aiming to evaluate the existence and integrity of the radioprotection equipment, manner and conditions of image processing; and radiographic equipment parameters such as the dimension of the irradiation filed, the total filtration, the exposure time and the potential applied to the X ray tube. For an estimation of the skin entrance dose of the patient, the phantom Randon Alderson and thermoluminescence dosemeters were used. From these values and the conversion factors determined by the Monte Carlo technique, with the phantom MAX it was possible to estimate the dose absorbed in the organ due to the tele radiography procedures. Regarding panoramic radiography the study showed that the more elevated doses occurred in the parotid gland region which is near rotational venters. In the case of tele radiography the highest dose value occurred in the regions corresponding to the temporal lobe of the brain, followed by linfonodes, ears and parotid glands. The doses absorbed in the eyes and the thyroid gland were, 0.037 mGy and 0.002 mGy in Clinic A and 0.062 mGy and 0.003 mGy in Clinic C, respectively. Regarding equipment test, inadequacy was found in the beam collimation in Clinic A and in the reproducibility of the X ray exposure in Clinic C. The total filtration in both clinics was inadequate.(author)

  8. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  9. Computed radiography in neonatal intensive care

    Energy Technology Data Exchange (ETDEWEB)

    Merlo, L.; Bighi, S.; Cervi, P.M.; Lupi, L. (S. Anna Hospital, Ferrara (Italy). Dept. of Radiology)

    1991-02-01

    The Authors report their experience in the employment of a computerized digital radiographic system in Neonatal Intensive Care. The analog screen-film system is replaced by photosensitive imaging plates, scanned after X-ray exposure by a laser that releases the digital image, which can then be manipulated on computer work-stations. In a period of twelve months about 200 chest-abdomen X-ray examinations in Neonatal Intensive Care have been performed using this method with good technical and diagnostic results. The use of digital radiography in the neonatal area is of high interest: this system produces good quality images, there is a reduction in radiation dose and 'retakes', the system allows selective enhancement of different structures and their magnification. (orig.).

  10. Computed radiography imaging plates and associated methods of manufacture

    Science.gov (United States)

    Henry, Nathaniel F.; Moses, Alex K.

    2015-08-18

    Computed radiography imaging plates incorporating an intensifying material that is coupled to or intermixed with the phosphor layer, allowing electrons and/or low energy x-rays to impart their energy on the phosphor layer, while decreasing internal scattering and increasing resolution. The radiation needed to perform radiography can also be reduced as a result.

  11. Dentomaxillofacial imaging with computed-radiography techniques: a preliminary study

    Science.gov (United States)

    Shaw, Chris C.; Kapa, Stanley F.; Furkart, Audrey J.; Gur, David

    1993-09-01

    A preliminary study was conducted to investigate the feasibility of using high resolution computed radiography techniques for dentomaxillofacial imaging. Storage phosphors were cut into various sizes and used with an experimental laser scanning reader for three different imaging procedures: intraoral, cephalometric and panoramic. Both phantom and patient images were obtained for comparing the computed radiography technique with the conventional screen/film or dental film techniques. It has been found that current computed radiography techniques are largely adequate for cephalometric and panoramic imaging but need further improvement on their spatial resolution capability for intraoral imaging. In this paper, the methods of applying the computer radiography techniques to dentomaxillofacial imaging are described and discussed. Images of phantoms, resolution bar patterns and patients are presented and compared. Issues on image quality and cost are discussed.

  12. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  13. Simulation of computed radiography with imaging plate detectors

    Science.gov (United States)

    Tisseur, D.; Costin, M.; Mathy, F.; Schumm, A.

    2014-02-01

    Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI.

  14. Spectrum optimization for computed radiography mammography systems.

    Science.gov (United States)

    Figl, Michael; Homolka, Peter; Semturs, Friedrich; Kaar, Marcus; Hummel, Johann

    2016-08-01

    Technical quality assurance is a key issue in breast screening protocols. While full-field digital mammography systems produce excellent image quality at low dose, it appears difficult with computed radiography (CR) systems to fulfill the requirements for image quality, and to keep the dose below the limits. However, powder plate CR systems are still widely used, e.g., they represent ∼30% of the devices in the Austrian breast cancer screening program. For these systems the selection of an optimal spectrum is a key issue. We investigated different anode/filter (A/F) combinations over the clinical range of tube voltages. The figure-of-merit (FOM) to be optimized was squared signal-difference-to-noise ratio divided by glandular dose. Measurements were performed on a Siemens Mammomat 3000 with a Fuji Profect reader (SiFu) and on a GE Senograph DMR with a Carestream reader (GECa). For 50mm PMMA the maximum FOM was found with a Mo/Rh spectrum between 27kVp and 29kVp, while with 60mm Mo/Rh at 28kVp (GECa) and W/Rh 25kVp (SiFu) were superior. For 70mm PMMA the Rh/Rh spectrum had a peak at about 31kVp (GECa). FOM increases from 10% to >100% are demonstrated. Optimization as proposed in this paper can either lead to dose reduction with comparable image quality or image quality improvement if necessary. For systems with limited A/F combinations the choice of tube voltage is of considerable importance. In this work, optimization of AEC parameters such as anode-filter combination and tube potential was demonstrated for mammographic CR systems. Copyright © 2016. Published by Elsevier Ltd.

  15. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  16. Computed tomography of calcaneal fractures. Comparison with conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ishino, Youichi; Oono, Masato; Uchino, Akira; Satou, Yoshiyuki; Nakata, Hajime.

    1989-03-01

    Computed tomography (CT) and conventional radiography were compared in 52 calcaneal fractures. As for CT, direct coronal imagings were performed in all and direct axial imagings were added in 27 of them. Conventional radiography included lateral, axial, and Anthonsen (oblique) views. Overall CT detected 7 more of the incongruity of the posterior facet, 9 more of the bulging of the lateral wall, and 6 more of the fracture of the sustentaculum tali than conventional radiography. In addition the entrapment of the peroneal tendons between the calcaneal body and the fibular malleolus could be evaluated only with CT. These informations are indispensable for the proper treatment of the fractures and we conclude that CT is useful in evaluating calcaneal fractures. (author).

  17. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement.

    NARCIS (Netherlands)

    Boo, D.W. De; Weber, M.; Deurloo, E.E.; Streekstra, G.J.; Freling, N.J.; Dongelmans, D.A.; Schaefer-Prokop, C.M.

    2011-01-01

    AIM: To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). METHODS AND MATERIALS: Three groups of age-, weight- and disease-matched ICU patients

  18. Computer-aided diagnosis in chest radiography

    NARCIS (Netherlands)

    Ginneken, B. van

    2001-01-01

    Chest radiographs account for more than half of all radiological examinations; the chest is the “mirror of health and disease”. This thesis is about techniques for computer analysis of chest radiographs. It describes methods for texture analysis and segmenting the lung fields and rib cage in a

  19. A method to optimize the processing algorithm of a computed radiography system for chest radiography.

    Science.gov (United States)

    Moore, C S; Liney, G P; Beavis, A W; Saunderson, J R

    2007-09-01

    A test methodology using an anthropomorphic-equivalent chest phantom is described for the optimization of the Agfa computed radiography "MUSICA" processing algorithm for chest radiography. The contrast-to-noise ratio (CNR) in the lung, heart and diaphragm regions of the phantom, and the "system modulation transfer function" (sMTF) in the lung region, were measured using test tools embedded in the phantom. Using these parameters the MUSICA processing algorithm was optimized with respect to low-contrast detectability and spatial resolution. Two optimum "MUSICA parameter sets" were derived respectively for maximizing the CNR and sMTF in each region of the phantom. Further work is required to find the relative importance of low-contrast detectability and spatial resolution in chest images, from which the definitive optimum MUSICA parameter set can then be derived. Prior to this further work, a compromised optimum MUSICA parameter set was applied to a range of clinical images. A group of experienced image evaluators scored these images alongside images produced from the same radiographs using the MUSICA parameter set in clinical use at the time. The compromised optimum MUSICA parameter set was shown to produce measurably better images.

  20. Management of pediatric radiation dose using Agfa computed radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schaetzing, R. [Agfa Corp., Greenville, SC (United States)

    2004-10-01

    Radiation dose to patients and its management have become important considerations in modern radiographic imaging procedures, but they acquire particular significance in the imaging of children. Because of their longer life expectancy, children exposed to radiation are thought to have a significantly increased risk of radiation-related late sequelae compared to adults first exposed to radiation later in life. Therefore, current clinical thinking dictates that dose in pediatric radiography be minimized, while simultaneously ensuring sufficient diagnostic information in the image, and reducing the need for repeat exposures. Dose management obviously starts with characterization and control of the exposure technique. However, it extends farther through the imaging chain to the acquisition system, and even to the image processing techniques used to optimize acquired images for display. Further, other factors, such as quality control procedures and the ability to handle special pediatric procedures, like scoliosis exams, also come into play. The need for dose management in modern radiography systems has spawned a variety of different solutions, some of which are similar across different manufacturers, and some of which are unique. This paper covers the techniques used in Agfa Computed Radiography (CR) systems to manage dose in a pediatric environment. (orig.)

  1. Computers in dental radiography: a scenario for the future

    Energy Technology Data Exchange (ETDEWEB)

    Webber, R.L.

    1985-09-01

    The recent emergence of cost-effective computing power makes it possible to integrate sophisticated data-sampling and image-interpretation techniques into dental radiography for the first time. A prototype system is being developed to permit clinical information expressed in three dimensions--plus time--to be made visible almost instantly. The associated X-ray dose for a complete three-dimensional survey of a selected dental region is predicted to be less than that required for a single conventional periapical radiograph exposed on D-speed film.

  2. Paediatric entrance doses from exposure index in computed radiography

    Science.gov (United States)

    Vano, E.; Martinez, D.; Fernandez, J. M.; Ordiales, J. M.; Prieto, C.; Floriano, A.; Ten, J. I.

    2008-06-01

    Over the last two years we have evaluated paediatric patient doses in projection radiography derived from exposure level (EL) in computed radiography (CR) in a large university hospital. Entrance surface air kerma (ESAK) for 3501 paediatric examinations was calculated from the EL, which is a dose index parameter related to the light emitted by the phosphor-stimulable plate, archived in the Digital Imaging and Communications in Medicine (DICOM) header of the images and automatically transferred to a database using custom-built dedicated software. Typical mean thicknesses for several age bands of paediatric patients was estimated to calculate ESAK from the EL values, using results of experimental measurements with phantoms for the typical x-ray beam qualities used in paediatric examinations. Mean/median ESAK values (in µGy) for the age bands of images used for the (indirect) measurements were 1724 for chest without a bucky, 799 for chest with a bucky, 337 for abdomen and 641 for pelvis. The methodology we describe could be applicable to other centres using CR as an imaging modality for paediatrics. Presently, this method is the only practical approach to automatically extract parameters contained in the DICOM header, for the calculation of patient dose values for the CR modality.

  3. Detection of urinary stones at reduced radiation exposure: a phantom study comparing computed radiography and a low-dose digital radiography linear slit scanning system

    Science.gov (United States)

    Szucs-Farkas, Zsolt; Chakraborty, D. P.; Thoeny, Harriet C.; Loupatatzis, Christos; Vock, Peter; Harald, Bonel

    2010-01-01

    Objective In this experimental study we assessed the diagnostic performance of linear slit scanning radiography (LSSR) compared to conventional computed radiography (CR) in the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58 to 88 kg. Conclusion Compared to computed radiography, LSSR is superior in the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure. PMID:19457787

  4. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...... that osteological ageing and sexing are more accurate when combining CT-images with excavated remains. Digital volume rendering further enables a compromised estimation of original cremation weight. Microexcavation is clearly a primary cause of bone fragmentation. Cremated remains affected by lower cremation...

  5. Method and Apparatus for Computed Imaging Backscatter Radiography

    Science.gov (United States)

    Shedlock, Daniel (Inventor); Meng, Christopher (Inventor); Sabri, Nissia (Inventor); Dugan, Edward T. (Inventor); Jacobs, Alan M. (Inventor)

    2013-01-01

    Systems and methods of x-ray backscatter radiography are provided. A single-sided, non-destructive imaging technique utilizing x-ray radiation to image subsurface features is disclosed, capable of scanning a region using a fan beam aperture and gathering data using rotational motion.

  6. Concrescence: assessment of case by periapical radiography, cone beam computed tomography and micro-computed tomography.

    Science.gov (United States)

    Neves, Frederico Sampaio; Rovaris, Karla; Oliveira, Matheus Lima; Novaes, Pedro Duarte; de Freitas, Deborah Queiroz

    2014-04-01

    The aim of this article was to describe imaging aspects of concrescence analyzed by three imaging modalities. A second molar joined together with a third molar was imaged using digital periapical radiography, cone beam computed tomography (CBCT) and micro-computed tomography (Micro-CT). On periapical radiograph, the mesial root of the third molar is superimposed on the distal root of the second molar. On CBCT images, a large cementum union between bulbous roots was detected, confirming the diagnosis of concrescence. On micro-CT images, the cementum union appeared limited to the apical third of the roots. In conclusion, both computed tomography modalities allowed for the diagnosis of concrescence. However, only micro-CT provided the real extension of the cementum union.

  7. Reducing the radiation dose during excretory urography: flat-panel silicon x-ray detector versus computed radiography.

    Science.gov (United States)

    Zähringer, M; Hesselmann, V; Schulte, O; Kamm, K F; Braun, W; Haupt, G; Krug, B; Lackner, K

    2003-10-01

    The purpose of the study was to examine the possibilities for reducing radiation exposure in uroradiology using digital flat-panel silicon X-ray detector radiography. We compared the subjectively determined image quality of abdominal radiographs and urograms obtained on a digital flat-panel detector radiography system with those obtained on a computed radiography system. SUBJECTS AND METHODS. Fifty patients who had a clinical indication for urography underwent unenhanced abdominal imaging that was alternately performed using flat-panel silicon X-ray detector radiography or computed radiography. For patients who required a second radiograph with contrast medium, the examination modality was changed to avoid exposing the patients to excess radiation. The images obtained on flat-panel X-ray detector radiography were obtained at half the radiation dose of the images obtained on computed radiography (800 speed vs 400 speed). The resulting 50 pairs of images were interpreted by four independent observers who rated the detectability of structures of bone and the efferent urinary tract relevant to diagnosis and compared the image quality. At half the radiation dose, digital flat-panel X-ray detector radiography provided equivalent image quality of the liver and spleen, lumbar vertebrae 2 and 5, pelvis, and psoas margin on abdominal radiographs. The image quality obtained with digital flat-panel X-ray detector radiography of the kidneys, the hollow cavities of the upper efferent urinary tract, and the urinary bladder was judged to be statistically better than those obtained with computed radiography. With half the exposure dose of computed radiography, the flat-panel X-ray detector produced urograms with an image quality equivalent to or better than computed radiography.

  8. Computed radiography (FCR) with a dual side reading system. Comparison with conventional radiography for visualization of nodular lung cancers

    Energy Technology Data Exchange (ETDEWEB)

    Ha-kawa, Shangkil; Yoshida, Tsunetaka; Sougawa, Mitsuharu; Harima, Yohko; Sawada, Satoshi [Kansai Medical Univ., Moriguchi, Osaka (Japan)

    2003-02-01

    To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the hilum of the lung or mediastinum. In large nodular shadows which were the most frequent abnormality score +1 or +2 were observed in 43% of adenocarcinoma and 26% of squamous cell lung cancer. FCR with the dual side reading system is superior to the conventional screen-film system for visualization of nodular lung cancers. (author)

  9. Observer training for computer-aided detection of pulmonary nodules in chest radiography

    NARCIS (Netherlands)

    de Boo, Diederick W.; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J.; Freling, Nicole J.; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M.

    2012-01-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a

  10. First Results and Realization Status of a Proton Computed Radiography Device

    Energy Technology Data Exchange (ETDEWEB)

    Sipala, V. [Dipt. di Fisica, Univ. degli Studi di Catania, via S. Sofia 64, I-95123, Catania (Italy); INFN, sezione di Catania, via S. Sofia 64, I-95123, Catania (Italy); Bruzzi, M. [Dipt. di Energetica, Univ. degli Studi di Firenze, via S. Marta 3, I-50139 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Bucciolini, M. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Dipt. di Fisiopatologia Clinica, Univ. degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); Candiano, G. [Lab. Nazionali del Sud-INFN, via S. Sofia 62, I-95123, Catania (Italy); Capineri, L. [Dipt. di Elettronica e Telecomunicazioni, Univ. degli Studi di Firenze, via S. Marta 3, I-50139 Firenze (Italy); Cirrone, G.A.P. [Lab. Nazionali del Sud-INFN, via S. Sofia 62, I-95123, Catania (Italy); Civinini, C. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Cuttone, G. [Lab. Nazionali del Sud-INFN, via S. Sofia 62, I-95123, Catania (Italy); Lo Presti, D. [Dipt. di Fisica, Univ. degli Studi di Catania, via S. Sofia 64, I-95123, Catania (Italy); INFN, sezione di Catania, via S. Sofia 64, I-95123, Catania (Italy); Marrazzo, L. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Dipt. di Fisiopatologia Clinica, Univ. degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); Menichelli, D. [Dipt. di Energetica, Univ. degli Studi di Firenze, via S. Marta 3, I-50139 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Randazzo, N. [INFN, sezione di Catania, via S. Sofia 64, I-95123, Catania (Italy); Talamonti, C. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Dipt. di Fisiopatologia Clinica, Univ. degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy)

    2009-12-15

    The PRIMA (PRoton IMAging) collaboration, supported by INFN and MIUR, is realizing a proton Computed Radiography device suitable to acquire the single proton with 1MHz rate for application in proton therapy. Its design and the first results obtained are presented.

  11. Diagnostic Imaging of the Lower Respiratory Tract in Neonatal Foals: Radiography and Computed Tomography.

    Science.gov (United States)

    Lascola, Kara M; Joslyn, Stephen

    2015-12-01

    Diagnostic imaging plays an essential role in the diagnosis and monitoring of lower respiratory disease in neonatal foals. Radiography is most widely available to equine practitioners and is the primary modality that has been used for the characterization of respiratory disease in foals. Computed tomography imaging, although still limited in availability to the general practitioner, offers advantages over radiography and has been used diagnostically in neonatal foals with respiratory disease. Recognition of appropriate imaging protocols and patient-associated artifacts is critical for accurate image interpretation regardless of the modality used. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Imaging suspected cervical spine injury: Plain radiography or computed tomography? Systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Cain, Gavin [Diagnostic Radiographer, Colchester Hospital University NHS Foundation Trust, Colchester General Hospital, Turner Road, Colchester, CO4 5JL Essex (United Kingdom)], E-mail: gavincain8@hotmail.com; Shepherdson, Jane; Elliott, Vicki; Svensson, Jon [Faculty of Health and Social Care, Anglia Ruskin University, East Road, Cambridge, CB1 9PT Cambridgeshire (United Kingdom); Brennan, Patrick [UCD School of Medicine and Medical Sciences, Health Science Building, Belfield, Dublin 4 (Ireland)

    2010-02-15

    Aim: (1) to establish which modality offers the greatest accuracy in the detection of cervical spine injury (CSI) Following trauma: plain radiography or computed tomography (CT), and (2) make an evidence-based recommendation for the initial imaging modality of choice. Method: A systematic literature review was performed to identify primary research studies which compare the diagnostic accuracy of plain radiography and CT with the results of a reference standard in the detection of CSI. A search of MEDLINE, EMBASE, CINAHL, Science Direct and Pubmed Central databases was conducted. Results: Ten studies were identified. Critical appraisal identified limitations among all studies. There was heterogeneity in the sensitivity estimates for plain radiography, whereas estimates for CT were consistently high. Examination of the reported sensitivities shows that CT outperforms plain radiography in the detection of CSI. Conclusion: CT is superior to plain radiography in the detection of CSI. However, the optimal imaging strategy depends on the patients' relative risk of injury. If at high-risk cervical CT is indicated. If at low-risk the increased cost and radiation exposure mean that screening CT may not be warranted, good-quality plain radiographs are sufficient.

  13. Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography.

    Science.gov (United States)

    Patel, S; Dawood, A; Mannocci, F; Wilson, R; Pitt Ford, T

    2009-06-01

    To compare the diagnostic accuracy of intraoral digital periapical radiography with that of cone beam computed tomography (CBCT) for the detection of artificial periapical bone defects in dry human jaws. Small and large artificial periapical lesions were prepared in the periapical region of the distal root of six molar teeth in human mandibles. Scans and radiographs were taken with a charged couple device (CCD) digital radiography system and a CBCT scanner before and after each periapical lesion had been created. Sensitivity, specificity, positive predictive values, negative predictive values and Receiver Operator Characteristic (ROC) curves as well as the reproducibility of each technique were determined. The overall sensitivity was 0.248 and 1.0 for intraoral radiography and CBCT respectively, i.e. these techniques correctly identified periapical lesions in 24.8% and 100% of cases, respectively. Both imaging techniques had specificity values of 1.0. The ROC Az values were 0.791 and 1.000 for intraoral radiography and CBCT, respectively. With intraoral radiography, external factors (i.e. anatomical noise and poor irradiation geometry), which are not in the clinician's control, hinder the detection of periapical lesions. CBCT removes these external factors. In addition, it allows the clinician to select the most relevant views of the area of interest resulting in improved detection of the presence and absence of artificial periapical lesions.

  14. Computed radiography in scoliosis. Diagnostic information and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, A. [Dept. of Diagnostic Radiology, Univ. Hospital, Lund (Sweden); Jonsson, K. [Dept. of Diagnostic Radiology, Univ. Hospital, Lund (Sweden); Eklund, K. [Dept. of Diagnostic Radiology, Univ. Hospital, Lund (Sweden); Holje, G. [Dept. of Diagnostic Radiology, Univ. Hospital, Lund (Sweden); Pettersson, H. [Dept. of Diagnostic Radiology, Univ. Hospital, Lund (Sweden)

    1995-07-01

    The diagnostic information and radiation dose in scoliosis examinations performed with air-gap technique using stimulable phosphor imaging plates were determined in a prospective study. Overlapping p.a. images of the thoracic and lumbar spine in 9 patients were obtained with 4 different exposure settings according to patient size. Equal exposure settings were used for the 2 images. Two images of 18 were judged inferior in depicting the landmarks of scoliosis measurement, requiring re-exposure. Sixteen images were judged of adequate or good quality. The mean entrance doses in the central beam for the 4 patient groups were in the interval of 0.05 to 0.12 mGy for both images. The skin doses on the breasts were in the range of 0.00 to 0.03 mGy. The presented technique thus results in a low radiation dose with sufficient diagnostic information in radiography of scoliosis. (orig.).

  15. Comparison of diagnostic accuracy of root perforation, external resorption and fractures using cone-beam computed tomography, panoramic radiography and conventional & digital periapical radiography.

    Science.gov (United States)

    Takeshita, Wilton Mitsunari; Chicarelli, Mariliani; Iwaki, Lilian Cristina Vessoni

    2015-01-01

    Some radicular changes are challenging for clinicians to diagnose, such as of root perforations, external root resorption (ERR), and vertical root fractures (VRFs). This study aims to facilitate it by comparing the diagnostic accuracy of cone-beam computed tomography (CBCT), orthopantomography, and conventional and digital periapical radiography (DPR) in the diagnosis of such problems. Is it worth doing CBCT despite the radiation dose? To evaluate and compare the diagnostic accuracy of CBCT, panoramic radiography, and conventional and DPR in the diagnosis of root perforation (RP), ERR, and VRF. The sample consisted of 40 extracted human teeth and 10 macerated human mandibles. RPs were performed using diamond burs, ERRs using spherical carbide burs, and RFs using a universal machine EMIC-DL 1000. The images were evaluated by 6 dentomaxillofacial radiologists. Receiver operating characteristic (ROC) revealed that CBCT showed the highest area under the ROC curve (Az) values for RP, ERR, and VRF (0.903, 0.950, and 0.849, respectively). The worst Az values for RP, ERR, and VRF (0.718, 0.494, and 0.611, respectively) were for panoramic radiography. CBCT showed the best results in the diagnosis of ERR and VRF. The diagnosis of ERR was the least accurate, panoramic radiography being not appropriate for its diagnosis. CBCT and conventional periapical radiography obtained similar results for the evaluation of RP. So for, RP indicate the conventional periapical radiography because CBCT has a higher radiation dose.

  16. A computer-assisted systematic quality monitoring method for cervical hip fracture radiography

    Science.gov (United States)

    Laurin, Olof; Johnsson, Ragnar; Laurin, Sven

    2016-01-01

    Background A thorough quality analysis of radiologic performance is cumbersome. Instead, the prevalence of missed cervical hip fractures might be used as a quality indicator. Purpose To validate a computer-based quality study of cervical hip fracture radiography. Material and Methods True and false negative and positive hip trauma radiography during 6 years was assessed manually. Patients with two or more radiologic hip examinations before surgery were selected by computer analysis of the databases. The first of two preoperative examinations might constitute a missed fracture. These cases were reviewed. Results Out of 1621 cervical hip fractures, manual perusal found 51 (3.1%) false negative radiographic diagnoses. Among approximately 14,000 radiographic hip examinations, there were 27 (0.2%) false positive diagnoses. Fifty-seven percent of false negative reports were occult fractures, the other diagnostic mistakes. There were no significant differences over the years. Diagnostic sensitivity was 96.9% and specificity 99.8%. Computer-assisted analysis with a time interval of at least 120 days between the first and the second radiographic examination discovered 39 of the 51 false negative reports. Conclusion Cervical hip trauma radiography has high sensitivity and specificity. With computer-assisted analysis, 76% of false negative reports were found. PMID:27994880

  17. The contrast-detail behaviour of a photostimulable phosphor based computed radiography system.

    Science.gov (United States)

    Marshall, N W; Faulkner, K; Busch, H P; Lehmann, K J

    1994-12-01

    Contrast-detail measurements were performed on a computed radiography imaging system as a function of detector entrance air kerma over the dose range from 0.743 microGy (0.085 mR) to 277 microGy (31.8 mR). A theoretical model of contrast-detail behaviour for a photostimulable phosphor computed radiography system has been derived, which is based on a modified version of the Rose theory of threshold detection. Included in the model are both system and x-ray quantum noise terms, as well as the response of the eye. The zero-frequency noise power of the computed film images was measured with a double-beam scanning microdensitometer. For a given detector dose, good agreement was found between the predicted and measured data when this measurement of system noise was included in the model. The contrast-detail results obtained for the computed radiography system were also compared with contrast-detail results for an image intensifier-TV based digital imaging system and a conventional film-screen system.

  18. Cone beam computed tomography and intraoral radiography for diagnosis of dental abnormalities in dogs and cats

    Science.gov (United States)

    Silva, Luiz Antonio F.; Barriviera, Mauricio; Januário, Alessandro L.; Bezerra, Ana Cristina B.; Fioravanti, Maria Clorinda S.

    2011-01-01

    The development of veterinary dentistry has substantially improved the ability to diagnose canine and feline dental abnormalities. Consequently, examinations previously performed only on humans are now available for small animals, thus improving the diagnostic quality. This has increased the need for technical qualification of veterinary professionals and increased technological investments. This study evaluated the use of cone beam computed tomography and intraoral radiography as complementary exams for diagnosing dental abnormalities in dogs and cats. Cone beam computed tomography was provided faster image acquisition with high image quality, was associated with low ionizing radiation levels, enabled image editing, and reduced the exam duration. Our results showed that radiography was an effective method for dental radiographic examination with low cost and fast execution times, and can be performed during surgical procedures. PMID:22122905

  19. Cone beam computed tomography and intraoral radiography for diagnosis of dental abnormalities in dogs and cats.

    Science.gov (United States)

    Roza, Marcello R; Silva, Luiz Antonio F; Barriviera, Mauricio; Januario, Alessandro L; Bezerra, Ana Cristina B; Fioravanti, Maria Clorinda S

    2011-12-01

    The development of veterinary dentistry has substantially improved the ability to diagnose canine and feline dental abnormalities. Consequently, examinations previously performed only on humans are now available for small animals, thus improving the diagnostic quality. This has increased the need for technical qualification of veterinary professionals and increased technological investments. This study evaluated the use of cone beam computed tomography and intraoral radiography as complementary exams for diagnosing dental abnormalities in dogs and cats. Cone beam computed tomography was provided faster image acquisition with high image quality, was associated with low ionizing radiation levels, enabled image editing, and reduced the exam duration. Our results showed that radiography was an effective method for dental radiographic examination with low cost and fast execution times, and can be performed during surgical procedures.

  20. Initial quality performance results using a phantom to simulate chest computed radiography

    OpenAIRE

    Muhogora Wilbroad; Padovani Renato; Msaki Peter

    2011-01-01

    The aim of this study was to develop a homemade phantom for quantitative quality control in chest computed radiography (CR). The phantom was constructed from copper, aluminium, and polymenthylmethacrylate (PMMA) plates as well as Styrofoam materials. Depending on combinations, the literature suggests that these materials can simulate the attenuation and scattering characteristics of lung, heart, and mediastinum. The lung, heart, and mediastinum regions were simulated by 10 mm x 10 mm x 0.5 mm...

  1. Automatic Measurement System For Congenital Hip Dislocation Using A Computed Radiography

    Science.gov (United States)

    Komori, M.; Minato, K.; Nakano, Y.; Hirakawa, A.; Kuwahara, M.

    1988-06-01

    Acetabular angle which is a diagnostic parameter of congenital hip dislocation has been measured manually in conventional X-ray film system. Using digital image directly provided from a computed radiography, an automatic measurement system was developed for this parameter. The process of the measurement was completed within a reasonable time, and accurate enough. The system was combined with an image database, so that it would be a measurement tool of PACS.

  2. Accuracy of cone-beam computed tomography and periapical radiography in detecting small periapical lesions.

    Science.gov (United States)

    Tsai, Patrick; Torabinejad, Mahmoud; Rice, Dwight; Azevedo, Bruno

    2012-07-01

    The aim of this study was to determine the diagnostic accuracy of 2 cone-beam computed tomography (CBCT) machines and periapical (PA) radiography in detecting simulated apical lesions created with the smallest dental burs available. By using mandibles from human cadavers, simulated apical lesions were created and then progressively enlarged in 16 roots by using sizes #1/4, #1/2, #1, #2, #4, and #6 round burs. Imaging was obtained after each enlargement with a Kodak 9000 3D (Kodak) CBCT, a Veraviewpocs 3De (Morita) CBCT, and intraoral digital PA radiography. Specificity and sensitivity at variable decision thresholds were calculated and plotted on receiver operator characteristic curves. The area under the curve (AUC) served as an estimate of diagnostic accuracy. The overall AUCs for Kodak, Morita, and PA radiography were 0.767 (95% confidence interval [CI], 0.743-0.792), 0.753 (95% CI, 0.728-0.779), and 0.584 (95% CI, 0.554-0.615), respectively. The AUCs for Kodak and Morita were both statistically significantly larger than the AUC for all corresponding simulated lesion sizes imaged with PA radiography. Between Kodak and Morita, there were no statistically significant differences in AUCs for any of the corresponding simulated lesion sizes. Both CBCT devices demonstrated poor accuracy in detecting simulated lesions smaller than 0.8 mm in diameter, fair to good accuracy when simulated lesion diameter was between 0.8-1.4 mm, and excellent accuracy when simulated lesions were larger than 1.4 mm in diameter. PA radiography, at best, demonstrated poor diagnostic accuracy for all simulated lesion sizes. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Accuracy of cone beam computed tomography, intraoral radiography, and periodontal probing for periodontal bone defects measurement

    Directory of Open Access Journals (Sweden)

    Eskandarlo A

    2011-02-01

    Full Text Available "nBackground and Aims: Cone beam computed tomography (CBCT produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods."nMaterials and Methods: Two-hundred and eighteen artificial osseous defects (buccal and lingual infrabony, interproximal, horizontal, crater, dehiscence and fenestration defects were created on 13 mandibles of dry skulls. The mandibles were put into a plexiglass box full of water to simulate soft tissue. CBCT images, radiographic images taken with parallel technique and direct measurements using a WHO periodontal probe were recorded and compared to a standard reference (digital caliper. Inter and intra observe consistencies were assessed using Intra class correlation coefficient and pearson correlation."nResults: Inter and intra observer consistencies were high for CBCT and probing methods (ICC- Intra class correlation coefficient>88%, but moderate for intraoral radiography (ICC-Intra class correlation coefficient > 54%. There were not any significant differences between observers for all techniques (P>0/05. According to paired T-test analysis, mean difference for CBCT technique (0.01 mm was lower than that for probing (0.04 mm and radiography (0.62 mm. CBCT was able to measure all kinds of lesions, but radiography could not measure defects in the buccal and lingual sites."nConclusion: All three modalities are useful for identifying periodontal defects. Compared to probing and radiography, the CBCT technique has the most accuracy in measuring periodontal defects.

  4. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference.

    Science.gov (United States)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji

    2013-08-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.

  5. Pelvic lipomatosis - its appearance on radiography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hold, M.; Olbert, F.; Schlegl, A.; Klumair, J.; Fochem, K.

    1981-06-01

    Case report on a case of pelvic lipomatosis, the 21. case published in the world literature. The typical radiographic findings, such as deformity of the urinary bladder and the abnormal course of the sigma, were seen. Computed tomography confirms the diagnosis.

  6. Validation of a computed radiography device to monitor the HIV-1 RNase H activity

    Energy Technology Data Exchange (ETDEWEB)

    Esposito, F. [Department of Biomedical Science and Technologies, University of Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Italy); Fanti, V. [Department of Physics, University of Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Italy); INFN Sezione di Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Italy); Marzeddu, R. [Department of Physics, University of Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Canada) (Italy); INFN Sezione di Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Italy)], E-mail: roberto.marzeddu@ca.infn.it; Randaccio, P. [Department of Physics, University of Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Italy); INFN Sezione di Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Italy); Tramontano, E.; Zinzula, L. [Department of Biomedical Science and Technologies, University of Cagliari, S.P. Monserrato-Sestu km. 0.7, 09042 Monserrato (Italy)

    2009-08-01

    A commercially available computed radiography (CR) system for dental radiography was used to produce images from radiolabeled polyacrilamide gel electrophoresis (PAGE) assays. Typically, similar investigations require specific and expensive autoradiography devices. The CR unit was characterized in terms of sensitivity and fading by means of a {sup 90}Sr source that well simulates the experimental conditions, and then used for quantitative analyses of the human immunodeficiency virus type 1 (HIV-1) reverse transcriptase (RT) polymerase-independent ribonuclease H (RNase H) activity monitored by PAGE analysis. The results showed that the present methodology allows quantifying effectively the RNase H catalyses and that the obtained data are in good agreement with previous reference works. Finally, in order to further validate the present method in terms of relationship between enzyme activity, the rate of products formation and signal intensity, a PAGE analyses of the HIV-1 RNase H inhibition by the known diketo acid derivative RDS1643 was carried out.

  7. Validation of a computed radiography device to monitor the HIV-1 RNase H activity

    Science.gov (United States)

    Esposito, F.; Fanti, V.; Marzeddu, R.; Randaccio, P.; Tramontano, E.; Zinzula, L.

    2009-08-01

    A commercially available computed radiography (CR) system for dental radiography was used to produce images from radiolabeled polyacrilamide gel electrophoresis (PAGE) assays. Typically, similar investigations require specific and expensive autoradiography devices. The CR unit was characterized in terms of sensitivity and fading by means of a 90Sr source that well simulates the experimental conditions, and then used for quantitative analyses of the human immunodeficiency virus type 1 (HIV-1) reverse transcriptase (RT) polymerase-independent ribonuclease H (RNase H) activity monitored by PAGE analysis. The results showed that the present methodology allows quantifying effectively the RNase H catalyses and that the obtained data are in good agreement with previous reference works. Finally, in order to further validate the present method in terms of relationship between enzyme activity, the rate of products formation and signal intensity, a PAGE analyses of the HIV-1 RNase H inhibition by the known diketo acid derivative RDS1643 was carried out.

  8. Bone height measurements of implant sites: Comparison of panoramic radiography and spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae [School of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    2002-06-15

    To compare the bone height of implant sites measured using panoramic radiography and spiral CT. The available bone height was determined for 263 maxillary and mandibular implant sites in 59 patients. Distortion was calculated using the metal bar for the panoramic radiographs. Significant differences in mean bone height between the two imaging modalities were found in maxillary and mandibular anterior regions (p<0.05). The mean difference in bone height recorded by the two techniques was smallest in the maxillary and mandibular molar areas (0.8 mm), and greatest in the mandibular anterior region (1.3 mm). With the exception of the mandibular anterior region, ninety percent of all the sites showed measurement differences within 2 mm. A safety margin of 2 to 3 mm is called for when utilizing panoramic radiography, otherwise additional imaging modality such as computed tomography is necessary to obtain accurate measurements.

  9. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur; Yaroshenko, Andre; Velroyen, Astrid

    2015-01-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering...... properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists...... of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually...

  10. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  11. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Directory of Open Access Journals (Sweden)

    Jakob Neubauer

    Full Text Available To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT and to radiography equivalent dose cone beam computed tomography (RED-CBCT for wrist fractures.As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100 were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care, RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT.Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = < .004. No significant differences were detected concerning the modalities' specificities (with values between P = .98. Raters' confidence was higher in RED-MDCT and RED-CBCT compared to radiography (P < .001.The diagnostic accuracy of RED-MDCT and RED-CBCT for wrist fractures proved to be similar and in some parts even higher compared to radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  12. Filter wheel equalization for chest radiography: a computer simulation.

    Science.gov (United States)

    Boone, J M; Duryea, J; Steiner, R M

    1995-07-01

    A chest radiographic equalization system using lung-shaped templates mounted on filter wheels is under development. Using this technique, 25 lung templates for each lung are available on two computer controlled wheels which are located in close proximity to the x-ray tube. The large magnification factor (> 10X) of the templates assures low-frequency equalization due to the blurring of the focal spot. A low-dose image is acquired without templates using a (generic) digital receptor, the image is analyzed, and the left and right lung fields are automatically identified using software developed for this purpose. The most appropriate left and right lung templates are independently selected and are positioned into the field of view at the proper location under computer control. Once the templates are positioned, acquisition of the equalized radiographic image onto film commences at clinical exposure levels. The templates reduce the exposure to the lung fields by attenuating a fraction of the incident x-ray fluence so that the exposure to the mediastinum and diaphragm areas can be increased without overexposing the lungs. A data base of 824 digitized chest radiographs was used to determine the shape of the specific lung templates, for both left and right lung fields. A second independent data base of 208 images was used to test the performance of the templates using computer simulations. The template shape characteristics derived from the clinical image data base are demonstrated. The detected exposure in the lung fields on conventional chest radiographs was found to be, on average, three times the detected exposure behind the diaphragm and mediastinum.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Comparison of Waters' radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Young Min; Lee, Sam Sun; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1998-02-15

    With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed: 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P<0.05), but there was no significant difference between two groups in the specificity (P>0.05). 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05)

  14. Evaluation of cone beam computed tomography and periapical radiography in the diagnosis of root resorption.

    Science.gov (United States)

    Lima, T F; Gamba, T O; Zaia, A A; Soares, A J

    2016-12-01

    This study aimed to evaluate the accuracy of cone beam computed tomography (CBCT) and periapical radiography in diagnosing root resorption and verify the influence of filling material in detecting these lesions. Digital periapical radiographs and CBCT images of patients with root resorption and a history of dental trauma from a radiology clinic were reviewed retrospectively. The sample comprised 40 teeth with root resorption and 20 normal teeth as controls. Images were analysed by two radiologists and two endodontists. The sensitivity, specificity and accuracy were determined. The kappa coefficient assessed interobserver agreement and the t test determined significant differences between the imaging methods. The accuracy of CBCT in diagnosing external (P = 0.0144) and internal (P = 0.0038) inflammatory resorption was significantly higher than for periapical radiography. For replacement resorption, no statistical difference was noted (P > 0.05). In endodontically treated teeth, CBCT was statistically superior in diagnosing root resorption (P = 0.0138). CBCT was superior to digital periapical radiography in diagnosing external and internal inflammatory root resorption after dental trauma and can be considered in the differential diagnosis of resorptive lesions in teeth with endodontic treatment. © 2016 Australian Dental Association.

  15. Comparison of diagnostic accuracy of root perforation, external resorption and fractures using cone-beam computed tomography, panoramic radiography and conventional & digital periapical radiography

    OpenAIRE

    Wilton Mitsunari Takeshita; Mariliani Chicarelli; Lilian Cristina Vessoni Iwaki

    2015-01-01

    Context: Some radicular changes are challenging for clinicians to diagnose, such as of root perforations, external root resorption (ERR), and vertical root fractures (VRFs). This study aims to facilitate it by comparing the diagnostic accuracy of cone-beam computed tomography (CBCT), orthopantomography, and conventional and digital periapical radiography (DPR) in the diagnosis of such problems. Is it worth doing CBCT despite the radiation dose? Aims: To evaluate and compare the diagnostic...

  16. Diagnostic sensitivity of ultrasound, radiography and computed tomography for gender determination in four species of lizards.

    Science.gov (United States)

    Di Ianni, Francesco; Volta, Antonella; Pelizzone, Igor; Manfredi, Sabrina; Gnudi, Giacomo; Parmigiani, Enrico

    2015-01-01

    Gender determination is frequently requested by reptile breeders, especially for species with poor or absent sexual dimorphism. The aims of the current study were to describe techniques and diagnostic sensitivities of ultrasound, radiography, and computed tomography for gender determination (identification of hemipenes) in four species of lizards. Nineteen lizards of known sex, belonging to four different species (Pogona vitticeps, Uromastyx aegyptia, Tiliqua scincoides, Gerrhosaurus major) were prospectively enrolled. With informed owner consent, ultrasound, noncontrast CT, contrast radiography, and contrast CT (with contrast medium administered into the cloaca) were performed in conscious animals. Imaging studies were reviewed by three different operators, each unaware of the gender of the animals and of the results of the other techniques. The lizard was classified as a male when hemipenes were identified. Nineteen lizards were included in the study, 10 females and nine males. The hemipenes were seen on ultrasound in only two male lizards, and appeared as oval hypoechoic structures. Radiographically, hemipenes filled with contrast medium appeared as spindle-shaped opacities. Noncontrast CT identified hemipenes in only two lizards, and these appeared as spindle-shaped kinked structures with hyperattenuating content consistent with smegma. Hemipenes were correctly identified in all nine males using contrast CT (accuracy of 100%). Accuracy of contrast radiography was excellent (94.7%). Accuracy of ultrasound and of noncontrast CT was poor (64.3% and 63.1%, respectively). Findings from the current study supported the use of contrast CT or contrast radiography for gender determination in lizards. © 2014 American College of Veterinary Radiology.

  17. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan); Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Abe, Takayuki [Keio University School of Medicine, Center for Clinical Research, Tokyo (Japan); Ogawa, Kenji [Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan)

    2013-08-15

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA{sub -950}) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA{sub -950}. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA{sub -950}. (orig.)

  18. Observer differentiation of proximal enamel mechanical defects versus natural proximal dental caries with computed dental radiography.

    Science.gov (United States)

    Kang, B C; Farman, A G; Scarfe, W C; Goldsmith, L J

    1996-10-01

    Various models have been used to study the accuracy of imaging systems for detection of dental caries. This study compares the ability of dentists to detect mechanically created defects versus natural dental caries cavitations on the proximal surfaces of extracted teeth with Computed Dental Radiography (Schick Industries, Long Island City, N.Y.). Detection rates are investigated according to lesion depth to permit comparisons to be made between studies in the literature with other mechanical defects or natural caries models. Discrimination of natural caries versus artificial defects with Computed Dental Radiography is also compared with a previous report that used standard dental film. Fifty-two extracted molar and premolar teeth were mounted into representative sets of maxillary and mandibular posterior arches for bite-wing radiography. There were 16 proximal surfaces with natural caries and 28 proximal surfaces with mechanical defects. An optical bench was used to ensure constant beam geometry. A 1.8 cm acrylic soft tissue equivalent attenuator was placed in front of the receptor. Thirty dentists acted independently as observers to differentiate between sound proximal tooth surfaces, natural dental caries, and mechanical defects. Evaluation of intra- and interobserver variability was made with use of the kappa statistic. The Zelen test of odds ratios was used to test for homogeneity, and the Mantel-Haenszel analysis plus stratified logistic regression were used for inference about the common odds ratio. Significance was set at p detection was 74% for mechanical defects and 67% for natural caries. The odds of detecting a mechanical defect were 1.40 times the odds of finding natural dental caries cavitation of the same depth. Lesion depth did influence the probability of correctly identifying the presence of a lesion; the odds of identifying cavitation increased 1.41 times with every 0.1 mm increase in lesion depth. Correct designation of lesion type was 1.42 times

  19. Radiological examination of postoperative maxillary cyst; Comparison between rotational panoramic radiography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Naitoh, Munetaka; Shiojima, Masaru; Kikuchi, Atsushi; Fukaya, Masahiko; Kawai, Tsuyoshi (Aichi-Gakuin Univ., Nagoya (Japan). School of Dentistry)

    1989-10-01

    We compared findings obtained by rotational panoramic radiography and computed tomography in postoperative maxillary cyst diagnosed histopathologically. The results were as follows: Twenty two patients (13 males and 9 females) were studied, the average age was 45.8 years and the average period after initial surgery of maxillary sinus was 24.6 years. In the rotational panoramic radiographs, the lesion had well-defined margin in 17 cases, slightly diffuse margin in 4 cases and diffuse margin in 1 case. In the 21 cases with well-defined and slightly diffuse margin the lesion occupied the maxillary sinus horizontally in 14 cases and the inferior border extended to the alveolar area in 20 cases. The forms of the lesions were classified into four types: round type, partially round type, simular sinus type and unsettled type. the lesion was unilocular in 14 cases. The location of the lesion obtained by different procedures agreed in 18 cases. 70% of lesions grouped round or partially round types in the rotational panormamic radiography were classified into the absorbed type in the computed tomography. (author).

  20. Development of a computer simulation system of intraoral radiography using perspective volume rendering of CT data

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, Kazutoshi, Tanaka, Takemasa [Kyushu Univ., Fukuoka (Japan). Dental Hospital; Yoshiura, Kazunori; Tokumori, Kenji; Kanda, Shigenobu [Kyushu Univ., Fukuoka (Japan). Faculty of Dental Science

    2002-03-01

    The purpose of this study was to evaluate the usefulness of a computer simulation system for intraoral radiography as an educational aid for radiographic training for dental students. A dried skull was scanned with a multidetector CT, and the series of slice data was transferred to a workstation. A software AVS Express Developer was used to construct the x-ray projected images from the CT slice data. Geometrical reproducibilities were confirmed using numerical phantoms. We simulated images using the perspective projection method with an average value algorithm on this software. Simulated images were compared with conventional film images projected from the same geometrical positions, including eccentric projection. Furthermore, to confirm the changes of the image depending on the projection angles of the x-ray beam, we constructed simulation images in which the root apexes were enhanced with the maximum value algorithm. Using this method, high resolution simulated images with perspective projection, as opposed to parallel, were constructed. Comparing with conventional film images, all major anatomic components could be visualized easily. Any intraoral radiographs at an arbitrary angular projection could be simulated, which was impossible in the conventional training schema for radiographic technique. Therefore, not only standard projected images but also eccentric projections could be displayed. A computer simulation system of intraoral radiography with this method may be useful for training in intraoral radiographic technique for dental students. (author)

  1. Radiography, computed tomography and virtual bronchoscopy in four dogs and two cats with lung lobe torsion.

    Science.gov (United States)

    Schultz, R M; Peters, J; Zwingenberger, A

    2009-07-01

    This report describes the imaging features of radiography, computed tomography and virtual bronchoscopy in dogs and cats with lung lobe torsions. The medical records, thoracic radiographs and computed tomography images of four dogs and two cats with confirmed lung lobe torsions were retrospectively reviewed. Computed tomography with virtual bronchoscopy showed bronchial narrowing, collapse or occlusion in all six animals, while this was only appreciated on one radiographic examination. A tapering terminating angle of the air-filled bronchus proximal or distal to the collapsed region was seen only on computed tomography and virtual bronchoscopy in all six animals. The vesicular emphysema pattern typical of lung lobe torsion was seen on three computed tomographies but only on one radiographic examination. The lung lobe torsion-specific findings of vesicular emphysema and a proximally narrowed or occluded bronchus were more easily recognised on computed tomography and virtual bronchoscopy than with radiographs. Computed tomography slices acquired through the bronchus and lung lobe of interest in a cat or dog with possible lung lobe torsion can be reformatted into virtual bronchoscopic images that can be utilised along with computed tomography to help make a more definitive preoperative diagnosis.

  2. Acute Knee Trauma: Analysis of Multidetector Computed Tomography Findings and Comparison with Conventional Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mustonen, A.O.T. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Koskinen, S.K. [Research Inst. of Military Medicine, Helsinki (Finland); Kiuru, M.J. [ORTON Orthopaedic Hospital, Helsinki (Finland)

    2005-12-01

    Purpose: To evaluate the multidetector computed tomography (MDCT) findings of acute knee trauma and to compare radiography with MDCT in patients referred ta level 1 trauma center. Material and Methods: During a 5-year period, a total of 415 MDCT examinations were performed on 409 patients with acute knee trauma to reveal complex fracture anatomy or rule out a fracture. MDCT and primary radiographs were re-evaluated with respect to fracture location and trauma mechanism. Tibial plateau fractures were further analyzed depending on anatomical location: anterior-medial, anterior-lateral, posterior-lateral, and posterior-medial regions. Maximal depression of the tibial articular surface was measured. Findings on the primary knee radiographs were compared with MDCT findings. Results: Of the 409 patients, 356 (87%) had a knee fracture. A total of 451 fractures were found in all anatomic regions: distal femur ( n = 49), proximal tibia ( n 307), patella ( n = 23), and proximal fibula ( n = 72). Primary radiographs were available in 316 (76%) cases. Of these, 225 (71%) had MDCT in order to reveal the fracture anatomy better, and 91 (29%) had a subsequent MDCT after negative plain radiographs. Overall sensitivity of radiography was 83%, while negative predictive value was 49%. On radiography, tibial plateau articular depression was underestimated in all regions except when the fracture consisted of the whole half of the anterior or posterior plateau. The three main injury mechanisms were traffic accident, a simple fall, and sport. In 49 cases (15%), primary radiographs were suboptimal due to positioning. Conclusion: In severely injured patients, diagnostically sufficient radiographs are difficult to obtain, and therefore a negative radiograph is not reliable in ruling out a fracture. In these patients, MDCT is a fast and accurate examination and is also recommended in patients with tibial plateau fractures or complex knee injuries in order to evaluate the fracture adequately.

  3. Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Abbas Shokri

    2015-02-01

    Full Text Available Objectives This study aimed to compare the accuracy of conventional intraoral (CI radiography, photostimulable phosphor (PSP radiography, cone beam computed tomography (CBCT and multidetector computed tomography (MDCT for detection of strip and root perforations in endodontically treated teeth. Materials and Methods Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation and at the external surface of 48 roots (root perforation; 48 roots were not perforated (control group. After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05. For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

  4. Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography.

    Science.gov (United States)

    Shokri, Abbas; Eskandarloo, Amir; Noruzi-Gangachin, Maruf; Khajeh, Samira

    2015-02-01

    This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

  5. [Stature estimation from length of tibias and fibulas measured in computed radiography of living body].

    Science.gov (United States)

    Fan, Tao; Chen, Xiao-Gang; Zhou, Xiao-Rong; Zhang, Zhao-Hui; Deng, Zhen-Hua; Wang, Hui-Xiang

    2008-04-01

    By measuring lengths of tibias and fibulas in computed radiography (CR) of living body, regression formulae for stature estimation were obtained from these measurements that were adapted to the population of northern adults of Han. The length of tibias and fibulas were measured in radiography, including 422 subjects (207 men and 215 women). The body height of each subject was also recorded. Linear regression analysis between body height and the length of tibias and fibulas , analysis of variance of hypothesis test of linear regression model and t-test of the partial regression coefficient were applied to establish the regression equations for stature estimation. Then the paired t-test between the predictive value and the actual body height, the residual analysis, the tests of equal scedasticity and colinearity had been done to evaluate whether the equations accord with the model. Thirty five regression equations which were statistical significant were obtained. The multiple correlation coefficient was from 0.909 to 0.823 and the standard error of the estimation was between 2.48-3.87 cm. The lengths of tibias and fibulas on the CR films could be helpful to estimate stature. These equations could be used to estimate the body height of the Han population in North China.

  6. Accuracy of digital peripical radiography and cone-beam computed tomography in detecting external root resorption

    Energy Technology Data Exchange (ETDEWEB)

    Creanga, Adriana Gabriela [Division of Dental Diagnostic Science, Rutgers School of Dental Medicine, Newark (United States); Geha, Hassem; Sankar, Vidya; Mcmahan, Clyde Alex; Noujeim, Marcel [University of Texas Health Science Center San Antonio, San Antonio (United States); Teixeira, Fabrico B. [Dept. of Endodontics, University of Iowa, Iowa City (United States)

    2015-09-15

    The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

  7. Comparison of periapical radiography with cone beam computed tomography in the diagnosis of vertical root fractures in teeth with metallic post

    OpenAIRE

    Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli da Silva; Sergio Sabio; Paulo Ricardo Febrairo Albino

    2014-01-01

    Aim: To compare the diagnostic accuracy of conventional periapical radiography and cone beam computed tomography (CBCT) in detecting vertical root fracture (VRF) in tooth with metallic post (MP). Materials and Methods: Twenty endodontically-treated teeth received MPs, artificial fractures were created in 10 teeth, and they were all examined with tomography and radiography. The sample consisted of periapical radiography with post and without post, and tomography with post and without post;...

  8. Standard practice for digital imaging and communication nondestructive evaluation (DICONDE) for computed radiography (CR) test methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice facilitates the interoperability of computed radiography (CR) imaging and data acquisition equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This practice is intended to be used in conjunction with Practice E2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival storage. The goal of Practice E2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE results on any system conforming to the DICONDE standard. Toward that end, Practice E2339 provides a data dictionary and a set of information modules that are applicable to all NDE modalities. This practice supplements Practice E2339 by providing information objec...

  9. Computed radiography systems performance evaluation;Avaliacao de desempenho de sistemas de radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  10. Initial quantitative evaluation of computed radiography in an intensive care unit

    Energy Technology Data Exchange (ETDEWEB)

    Hillis, D.J.; McDonald, I.G.; Kelly, W.J. [Saint Vincent`s Hospital, Fitzroy, VIC (Australia). Dept. of Clinical Services, Centre for the Study of Clinical Practice and Intensive Care Unit; Truran, R.D.; Hailey, D.M. [Australian Inst. of Health and Welfare, Canberra, ACT (Australia)

    1996-08-01

    The first computed radiography (CR) unit in Australia was installed at St Vincent`s Hospital, Melbourne, in February 1994. An initial qualitative evaluation of the attitude of the intensive care unit (ICU) physicians to the CR unit was conducted by use of a survey. The results of the survey of ICU physicians indicated that images were available faster than under the previous system and that the use of the CR system was preferred to evaluate chest tubes and line placements. While it is recognized that a further detailed radiological evaluation of the CR system is required to establish the diagnostic performance of CR compared with conventional film, some comments on the implementation of the system and ICU physician attitudes to the CR system are put forward for consideration by other hospitals examining the possible use of CR systems. 11 refs., 1 tab.

  11. Study of image processing condition of mammography using FCR (Fuji Computed Radiography)

    Energy Technology Data Exchange (ETDEWEB)

    Nakata, Mihoko

    1989-04-01

    Image processing conditions of mammography using FCR (Fuji Computed Radiography) to detect mass shadow, marginal findings and microcalcification of breast cancer were examined. The subjects of the examination for mass shadow and marginal finding were 25 cases out of 55 breast cancers operated from December 1986 to August 1988. Three surgeons and two radiologists evaluated processing conditions. The optimum conditions of spatial frequency enhancement were RN(1 or 3)RT(P)RE(1.0) for mass shadow and RN(7)RT(P)RE(2.0) for marginal finding under routine gradational enhancement condition. ROC curves obtained from the phantom with a granule of aluminum were used to optimize image processing condition for microcalcification. It was shown that GT(M)GA(1.0)GC(0.6)RN(9)RT(F)RE(4.0) gave the best detectability among five image processing conditions. (author).

  12. Comparison of direct digital mammography, computed radiography, and film-screen in the French national breast cancer screening program.

    Science.gov (United States)

    Séradour, Brigitte; Heid, Patrice; Estève, Jacques

    2014-01-01

    The purpose of this article was to compare the performance of digital mammography using hardcopy image reading against film-screen mammography in a French national routine population-based screening program with a decentralized organization. The French context offered the opportunity to examine separately computed radiography and direct digital mammography performances in a large cohort. The study includes 23,423 direct digital mammography, 73,320 computed radiography, and 65,514 film-screen mammography examinations performed by 123 facilities in Bouches du Rhône, France, for women 50-74 years old between 2008 and 2010. We compared abnormal mammography findings rate, cancer detection rate, and tumor characteristics among the technologies. Abnormal finding rates were higher for direct digital mammography (7.78% vs 6.11% for film-screen mammography and 5.34% for computed radiography), particularly in younger women and in denser breasts. Cancer detection rates were also higher for direct digital mammography (0.71% vs 0.66% for film-screen mammography and 0.55% for computed radiography). The contrast between detection rates was stronger for ductal carcinoma in situ. Breast density was the main factor explaining the differences in detection rates. For direct digital mammography only, the detection rate was clearly higher in dense breasts whatever the age (odds ratio, 2.20). Except for grade, no differences were recorded concerning tumor characteristics in which the proportion of high-grade tumors was larger for direct digital mammography for invasive and in situ tumors. Direct digital mammography has a higher detection rate than film-screen mammography in dense breasts and for tumors of high grade. This latter association warrants further study to measure the impact of technology on efficacy of screening. The data indicate that computed radiography detects fewer tumors than film-screen mammography in most instances.

  13. Xeroradiography and computed radiography comparative study on diagnosis for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Ikuya; Yasumura, Tadaki; Oka, Takahiro (Kyoto Prefectural Univ. of Medicine (Japan))

    1990-04-01

    Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good diagnostic information as accurate as that of XR but also permits a patient smaller radiation exposure. (author).

  14. Comparison of diagnostic accuracy of root perforation, external resorption and fractures using cone-beam computed tomography, panoramic radiography and conventional & digital periapical radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2015-01-01

    Conclusions: CBCT showed the best results in the diagnosis of ERR and VRF. The diagnosis of ERR was the least accurate, panoramic radiography being not appropriate for its diagnosis. CBCT and conventional periapical radiography obtained similar results for the evaluation of RP. So for, RP indicate the conventional periapical radiography because CBCT has a higher radiation dose.

  15. Diagnostic value of computed tomography, radiography and ultrasonography in metacarpophalangeal joint disorders in horses

    Directory of Open Access Journals (Sweden)

    V.M.V. Machado

    2016-02-01

    Full Text Available In modern society the work and athletic performance of horses has led to a very important animal production sector in which Brazil possesses the third largest horse stock. Among all equine lesions described, metacarpophalangeal (fetlock joint lesions are considered one of the main causes of lameness. Consequently, there is a need to improve the understanding and diagnosis of these injuries. The most efficient imaging diagnostic methods for the fetlock region are computed tomography, radiography and ultrasound. Imaging studies of the anatomical structures involving this joint are extremely important to obtain a more precise diagnose. The present study was performed in order to evaluate the capacity of different imaging diagnostic modalities to detect a variety of lesions in different fetlock structures. Twenty horses (Equus caballus used for horsemanship activities were referred to the Department of Animal Reproduction and Veterinary Radiology of São Paulo State University, Botucatu campus, with clinical signs of metacarpophalangeal joint injuries. Horses were submitted to radiographic and ultrasonographic exam and computed tomography scan. Image analysis revealed a significant capacity of these methods to characterize lesions in this region. However, computed tomography provided broader and better evaluation of lesions in bones and adjacent structures, because it allows the analysis to be performed on three-dimensional projections, with attenuation coefficients (window selections and tissue density measurement through Hounsfield Units (HU.

  16. Initial quality performance results using a phantom to simulate chest computed radiography.

    Science.gov (United States)

    Muhogora, Wilbroad; Padovani, Renato; Msaki, Peter

    2011-01-01

    The aim of this study was to develop a homemade phantom for quantitative quality control in chest computed radiography (CR). The phantom was constructed from copper, aluminium, and polymenthylmethacrylate (PMMA) plates as well as Styrofoam materials. Depending on combinations, the literature suggests that these materials can simulate the attenuation and scattering characteristics of lung, heart, and mediastinum. The lung, heart, and mediastinum regions were simulated by 10 mm x 10 mm x 0.5 mm, 10 mm x 10 mm x 0.5 mm and 10 mm x 10 mm x 1 mm copper plates, respectively. A test object of 100 mm x 100 mm and 0.2 mm thick copper was positioned to each region for CNR measurements. The phantom was exposed to x-rays generated by different tube potentials that covered settings in clinical use: 110-120 kVp (HVL=4.26-4.66 mm Al) at a source image distance (SID) of 180 cm. An approach similar to the recommended method in digital mammography was applied to determine the CNR values of phantom images produced by a Kodak CR 850A system with post-processing turned off. Subjective contrast-detail studies were also carried out by using images of Leeds TOR CDR test object acquired under similar exposure conditions as during CNR measurements. For clinical kVp conditions relevant to chest radiography, the CNR was highest over 90-100 kVp range. The CNR data correlated with the results of contrast detail observations. The values of clinical tube potentials at which CNR is the highest are regarded to be optimal kVp settings. The simplicity in phantom construction can offer easy implementation of related quality control program.

  17. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    Science.gov (United States)

    Einarsdóttir, Hildur; Yaroshenko, Andre; Velroyen, Astrid; Bech, Martin; Hellbach, Katharina; Auweter, Sigrid; Yildirim, Önder; Meinel, Felix G.; Eickelberg, Oliver; Reiser, Maximilian; Larsen, Rasmus; Kjær Ersbøll, Bjarne; Pfeiffer, Franz

    2015-12-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually annotated to build an experimental dataset. System performance was assessed by: (i) determining the quality of the segmentations; (ii) validating emphysema and fibrosis recognition by a linear support vector machine using leave-one-out cross-validation. In terms of segmentation quality, we obtained an overlap percentage (Ω) 92.63  ±  3.65%, Dice Similarity Coefficient (DSC) 89.74  ±  8.84% and Jaccard Similarity Coefficient 82.39  ±  12.62%. For classification, the accuracy, sensitivity and specificity of diseased lung recognition was 100%. Classification between emphysema and fibrosis resulted in an accuracy of 93%, whilst the sensitivity was 94% and specificity 88%. In addition to the automatic classification of lungs, deviation maps created by the CAD scheme provide a visual aid for medical experts to further assess the severity of pulmonary disease in the lung, and highlights regions affected.

  18. Initial quality performance results using a phantom to simulate chest computed radiography

    Directory of Open Access Journals (Sweden)

    Muhogora Wilbroad

    2011-01-01

    Full Text Available The aim of this study was to develop a homemade phantom for quantitative quality control in chest computed radiography (CR. The phantom was constructed from copper, aluminium, and polymenthylmethacrylate (PMMA plates as well as Styrofoam materials. Depending on combinations, the literature suggests that these materials can simulate the attenuation and scattering characteristics of lung, heart, and mediastinum. The lung, heart, and mediastinum regions were simulated by 10 mm x 10 mm x 0.5 mm, 10 mm x 10 mm x 0.5 mm and 10 mm x 10 mm x 1 mm copper plates, respectively. A test object of 100 mm x 100 mm and 0.2 mm thick copper was positioned to each region for CNR measurements. The phantom was exposed to x-rays generated by different tube potentials that covered settings in clinical use: 110-120 kVp (HVL=4.26-4.66 mm Al at a source image distance (SID of 180 cm. An approach similar to the recommended method in digital mammography was applied to determine the CNR values of phantom images produced by a Kodak CR 850A system with post-processing turned off. Subjective contrast-detail studies were also carried out by using images of Leeds TOR CDR test object acquired under similar exposure conditions as during CNR measurements. For clinical kVp conditions relevant to chest radiography, the CNR was highest over 90-100 kVp range. The CNR data correlated with the results of contrast detail observations. The values of clinical tube potentials at which CNR is the highest are regarded to be optimal kVp settings. The simplicity in phantom construction can offer easy implementation of related quality control program.

  19. Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss.

    Science.gov (United States)

    Takeshita, Wilton Mitsunari; Vessoni Iwaki, Lilian Cristina; Da Silva, Mariliani Chicarelli; Tonin, Renata Hernandes

    2014-07-01

    To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL). ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth - directly on the mandibles (control), using conventional periapical radiography with film holders (Rinn XCP and Han-Shin), digital periapical radiography with complementary metal-oxide semiconductor sensor, conventional panoramic, and cone-beam computed tomography (CBCT). Three programs were used to measure ABL on the images: Image tool 3.0 (University of Texas Health Sciences Center, San Antonio, Texas, USA), Kodak Imaging 6.1 (Kodak Dental Imaging 6.1, Carestream Health(®), Rochester, NY, USA), and i-CAT vision 1.6.20. Statistical analysis used ANOVA and Tukey's test at 5% significance level. The tomographic images showed the highest means, whereas the lowest were found for periapical with Han-Shin. Controls differed from periapical with Han-Shin (P periapical with Rinn XCP (P = 0.0066), periapical with Han-Shin (P periapical (P = 0.0027). Conventional periapicals with film holders differed from each other (P = 0.0007). Digital periapical differed from conventional periapical with Han-Shin (P = 0.0004). Conventional periapical with Han-Shin film holder was the only method that differed from the controls. CBCT had the closest means to the controls.

  20. SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval, D; Mlady, G; Selwyn, R [University of New Mexico School of Medicine, Albuquerque, NM (United States); Valenti, D; Bateman, T; Norris, V [University of New Mexico Hospital, Albuquerque, New Mexico (United States)

    2016-06-15

    Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality

  1. Effects of x-ray spectrum on the NPS of a computed radiography system

    Science.gov (United States)

    Fetterly, Kenneth A.; Hangiandreou, Nicholas J.

    2000-04-01

    The purpose of this work was to determine the effects of various incident x-ray beam spectra on the measured noise power spectrum (NPS) of a computed radiography (CR) image acquisition device. A CR phosphor was uniformly exposed to 1 mR with x-ray beams whose peak tube potentials were 70, 95, and 120 kVp that were filtered by various thicknesses of a 'patient equivalent phantom' (PEP; 2% aluminum, 98% acrylic by thickness), aluminum, and copper. From the uniform exposure images, NPS curves were calculated and their integral values were computed. The integral noise values were found to vary substantially as a function of x-ray beam spectral content. A simple x-ray beam and filter model that accounted for the shape of the filtered x-ray spectra and the mass energy absorption coefficient of the storage phosphor verified the qualitative behavior of the integral NPS values corresponding to changes in the incident x-ray beam used. The x-ray beam and filter combinations of 70 kVp and 10.1 cm of PEP filtration and 120 kVp and 20.2 cm of PEP filtration were chosen as standard techniques for evaluating clinical imaging systems. These two combinations represent a relatively low, clinically relevant CR noise (integral NPS equals 2.6 X 10-6 mm) technique and a relatively high, clinically relevant CR noise (integral NPS equals 3.3 X 10-6 mm) technique.

  2. Detection of various anatomic patterns of root canals in mandibular incisors using digital periapical radiography, 3 cone-beam computed tomographic scanners, and micro-computed tomographic imaging.

    Science.gov (United States)

    Paes da Silva Ramos Fernandes, Luciana Maria; Rice, Dwight; Ordinola-Zapata, Ronald; Alvares Capelozza, Ana Lucia; Bramante, Clovis Monteiro; Jaramillo, David; Christensen, Heidi

    2014-01-01

    The purpose of this study was to compare the accuracy of digital periapical (PA) radiography and 3 cone-beam computed tomographic (CBCT) scanners in the identification of various internal anatomic patterns in mandibular incisors. Forty mandibular incisors were scanned using micro-computed tomographic imaging as the gold standard to establish the internal anatomic pattern. The number of root canals and internal patterns were classified into type I (single canal, n = 12), type Ia (single oval canal, n = 12), and type III (2 canals, n = 16). The teeth were placed in a human mandible, and digital PA radiography and 3 CBCT scans (Kodak 9000 3D [Carestream Health, Rochester, NY], Veraviewepocs 3De [J Morita MFG Corp, Kyoto, Japan], NewTom 5G [QR Srl, Verona, Italy]) were performed. Two blinded examiners classified each tooth's anatomic pattern, which were then compared with the micro-computed tomographic determinations. Considering type I and type Ia, which both presented with 1 root canal, there was a high degree of accuracy for all methods used (P > .05). The same result was found for type III. When identifying the shape of single canals (type I), CBCT imaging was more accurate compared with PA radiography. Concerning oval canals (type Ia), there was a significant difference between PA radiography and NewTom CBCT (PA radiography = 44%, NewTom = 88%). However, there were no significant differences between the 3 CBCT units. Double-exposure digital PA radiography for mandibular incisors is sufficient for the identification of the number of root canals. All CBCT devices showed improved accuracy in the identification of single root canal anatomy when a narrow canal was present. However, the identification of oval canals was improved only with the NewTom CBCT device. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Comparison of radiography, computed tomography and magnetic resonance imaging in the detection of sacroiliitis accompanying ankylosing spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Wei; Feng Feng; Yang Hongzen; Jiang Ming [Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Dion, E.; Genant, H.K. [Department of Radiology, Musculoskeletal Section and Osteoporosis and Arthritis Research Group, University of California San Francisco, CA 94143-0628 (United States)

    1998-06-01

    Objective. To compare magnetic resonance (MR) imaging, computed tomography (CT), and radiography in the detection of sacroiliitis accompanying ankylosing spondylitis (AS). Design and subjects. Nine volunteers and 24 patients were recruited. Radiography, CT, and MR imaging were completed within a 1-week period in 24 patients with AS. In precontrast MR examination, spin-echo T1, fast spin-echo T2, and gradient echo with rephasing T2* images were obtained without fat saturation using a 0.3-T imager for all volunteers and patients. Postcontrast MR examination was performed using the same precontrast SE T1 sequence for patients with AS. Results and conclusions. MR imaging directly showed the normal cartilage in all 16 sacroiliac joints of the 8 volunteers. In the 24 patients with AS, cartilage abnormalities were observed in 42 sacroiliac joints. More diagnoses of sacroiliitis were made using MR and CT imaging than using radiography (P<0.001). Therefore, low-field-strength MR can be useful in detecting early sacroiliitis in patients with AS. MR imaging was able to reveal early cartilage changes and bone marrow edema, which could not be found by either CT or radiography. (orig.) With 5 figs., 4 tabs., 36 refs.

  4. Comparison of Cone-Beam Computed Tomography and Intraoral Radiography in Detection of Recurrent Caries under Composite Restorations.

    Science.gov (United States)

    Kasraei, Shahin; Shokri, Abbas; Poorolajal, Jalal; Khajeh, Samira; Rahmani, Hamid

    2017-01-01

    Secondary caries is the most common cause of dental restoration failures. This study aimed to compare the diagnostic accuracy of conventional and digital intraoral radiography and cone beam computed tomography (CBCT) for detection of recurrent caries around composite restorations. mesio-occluso-distal (MOD) cavities were prepared using bur on 45 extracted sound human molar teeth. The teeth were divided into 3 groups. In the control group, cavities were restored with composite resin after etching and bonding (n=15). In Group 2, 500-μm thick wax was placed over the buccal, lingual and gingival walls and the cavities were restored with composite resin. Group 3 specimens were subjected to pH cycling and artificial caries were created on the buccal, lingual and gingival walls. The cavities were restored with composite. Conventional and digital photo-stimulable phosphor (PSP; Optime) radiographs and two CBCTs images (NewTom 3G and Cranex 3D) were obtained from them. Presence or absence of caries in the cavity walls was assessed on these images. Data were analyzed using Kappa statistic. The diagnostic accuracy of CBCT was significantly higher than that of digital and conventional intraoral radiography (pintraoral radiography, respectively. CBCT has a higher diagnostic accuracy than digital and conventional intraoral radiography for detection of secondary caries around composite restorations.

  5. Comparison of cone - beam computed tomography and intraoral radiography in detection of recurrent caries under composite restorations

    Energy Technology Data Exchange (ETDEWEB)

    Kasraei, Shahin; Shokri, Abbas; Poorolajal, Jalal; Rahmani, Hamid, E-mail: Dr.a.shokri@gmail.com [Hamadan University of Medical Sciences Hamadan (Iran, Islamic Republic of); Khajeh, Samira [Kurdistan University of Medical Sciences, Sanandaj (Iran, Islamic Republic of)

    2017-01-15

    Secondary caries is the most common cause of dental restoration failures. This study aimed to compare the diagnostic accuracy of conventional and digital intraoral radiography and cone beam computed tomography (CBCT) for detection of recurrent caries around composite restorations mesio-occluso-distal (MOD) cavities were prepared using bur on 45 extracted sound human molar teeth. The teeth were divided into 3 groups. In the control group, cavities were restored with composite resin after etching and bonding (n=15). In Group 2, 500-μm thick wax was placed over the buccal, lingual and gingival walls and the cavities were restored with composite resin. Group 3 specimens were subjected to pH cycling and artificial caries were created on the buccal, lingual and gingival walls. The cavities were restored with composite. Conventional and digital photo-stimulable phosphor (PSP; Optime) radiographs and two CBCTs images (NewTom 3G and Cranex 3D) were obtained from them. Presence or absence of caries in the cavity walls was assessed on these images. Data were analyzed using Kappa statistic. The diagnostic accuracy of CBCT was significantly higher than that of digital and conventional intraoral radiography (p<0.05). The accuracy was 0.83, 0.78, 0.55 and 0.49 for CBCT Cranex 3D, CBCT NewTom 3G, conventional and digital intraoral radiography, respectively. CBCT has a higher diagnostic accuracy than digital and conventional intraoral radiography for detection of secondary caries around composite restorations. (author)

  6. Physical evaluation of computed radiography as a mammographic X-ray imaging system.

    Science.gov (United States)

    Workman, A; Cowen, A R; Brettle, D S

    1994-10-01

    The physical imaging properties of a computed radiography (CR) system operating under mammographic exposure conditions have been measured. These measurements include modulation transfer function (MTF), sensitometric response and noise power spectrum (NPS). These figures were used to derive signal-to-noise ratio (SNR) descriptors of the system performance. The same measures were derived for a mammographic film-screen system. The SNR properties of the CR system indicate superior low frequency performance over a wider dynamic range than the film-screen system. The spatial frequency dependent SNR properties of the CR system are, however, limited. The results of a psychophysical test support the results obtained from physical measurements. These results indicate that despite its limited sharpness, details of dimensions relevant to diagnosis in mammography (circular details 0.25 mm diameter to represent microcalcifications and 3 mm diameter to represent small masses) are reproduced using CR with SNRs which are at least comparable with those of a mammographic film-screen system.

  7. Comparative adoption of cone beam computed tomography and panoramic radiography machines across Australia.

    Science.gov (United States)

    Zhang, A; Critchley, S; Monsour, P A

    2016-12-01

    The aim of the present study was to assess the current adoption of cone beam computed tomography (CBCT) and panoramic radiography (PR) machines across Australia. Information regarding registered CBCT and PR machines was obtained from radiation regulators across Australia. The number of X-ray machines was correlated with the population size, the number of dentists, and the gross state product (GSP) per capita, to determine the best fitting regression model(s). In 2014, there were 232 CBCT and 1681 PR machines registered in Australia. Based on absolute counts, Queensland had the largest number of CBCT and PR machines whereas the Northern Territory had the smallest number. However, when based on accessibility in terms of the population size and the number of dentists, the Australian Capital Territory had the most CBCT machines and Western Australia had the most PR machines. The number of X-ray machines correlated strongly with both the population size and the number of dentists, but not with the GSP per capita. In 2014, the ratio of PR to CBCT machines was approximately 7:1. Projected increases in either the population size or the number of dentists could positively impact on the adoption of PR and CBCT machines in Australia. © 2016 Australian Dental Association.

  8. Visualisation of uric acid renal calculi (UARC) using computed radiography (CR)

    Energy Technology Data Exchange (ETDEWEB)

    Dom, Sulaiman M. [Medical Imaging Program, Faculty of Health Sciences, Universiti Teknologi MARA, 46000 Petaling Jaya (Malaysia)], E-mail: smd_dom@hotmail.com; Yusoff, Nadzri M.; Amin, Zulkifli M. [Medical Imaging Program, Faculty of Health Sciences, Universiti Teknologi MARA, 46000 Petaling Jaya (Malaysia)

    2010-05-15

    Aim: To investigate the capability of CR to visualise UARC through inverse image post-processing technique. Methods. A patient-equivalent phantom (PEP) consisting of six 2.5-cm thick Perspex layers and one 1-mm thick aluminium layer was used to represent human tissues and bones respectively. A total of eight exposures were made on PEP to radiograph 1 mm, 2 mm and 3 mm UARC located between three layers of 2-cm thick cattle muscle, positioned inside the PEP. After each exposure, a layer of Perspex was removed, and another exposure was made until only one Perspex layer and one layer of muscle (containing the three UARC) remained. For each exposure, two images (a positive and an inverse image) were produced for comparison using Fuji XG1 computed radiography system with IP0 type C-ST-VI Fuji imaging plate (equivalent to 400 speed radiographic screen-film systems). Results: In positive image, UARC of all three sizes (1 mm, 2 mm and 3 mm) located in the cattle muscle, cannot be visualised when the PEP consists of more than one layer of Perspex. In inverse image, the 3-mm UARC can be seen even when the PEP consists of five layers of Perspex. Conclusion: This study revealed the post-processing capability of CR to increase the visualisation of UARC which has been categorised as radiolucent. A further study of clinical image quality should be performed using blinded observers to test diagnostic accuracy, which was not included in this study.

  9. Patient dose, gray level and exposure index with a computed radiography system

    Science.gov (United States)

    Silva, T. R.; Yoshimura, E. M.

    2014-02-01

    Computed radiography (CR) is gradually replacing conventional screen-film system in Brazil. To assess image quality, manufactures provide the calculation of an exposure index through the acquisition software of the CR system. The objective of this study is to verify if the CR image can be used as an evaluator of patient absorbed dose too, through a relationship between the entrance skin dose and the exposure index or the gray level values obtained in the image. The CR system used for this study (Agfa model 30-X with NX acquisition software) calculates an exposure index called Log of the Median (lgM), related to the absorbed dose to the IP. The lgM value depends on the average gray level (called Scan Average Level (SAL)) of the segmented pixel value histogram of the whole image. A Rando male phantom was used to simulate a human body (chest and head), and was irradiated with an X-ray equipment, using usual radiologic techniques for chest exams. Thermoluminescent dosimeters (LiF, TLD100) were used to evaluate entrance skin dose and exit dose. The results showed a logarithm relation between entrance dose and SAL in the image center, regardless of the beam filtration. The exposure index varies linearly with the entrance dose, but the angular coefficient is beam quality dependent. We conclude that, with an adequate calibration, the CR system can be used to evaluate the patient absorbed dose.

  10. Use of effective detective quantum efficiency to optimise radiographic exposures for chest imaging with computed radiography

    Science.gov (United States)

    Ertan, Ferihan; Mackenzie, Alistair; Urbanczyk, Hannah J.; Ranger, Nicole T.; Samei, Ehsan

    2009-02-01

    The purpose of the work was to test if effective detective quantum efficiency (eDQE) could be useful for optimisation of radiographic factors for computed radiography (CR) for adult chest examinations. The eDQE was therefore measured across a range of kilovoltage, with and without an anti-scatter grid. The modulation transfer function, noise power spectra, transmission factor and scatter fraction were measured with a phantom made of sheets of Aluminum and Acrylic. The entrance air kerma was selected to give an effective dose of 4.9 μSv. The effective noise equivalent quanta (eNEQ) is introduced in this work. eNEQ can be considered equal to the number of X-ray quanta equivalent in the image corrected for the amount of scatter and the blurring processes. The eNEQ was then normalised to account for slight differences in the effective dose (eNEQED). The peak eNEQED was largest at 80 kV and 100 kV with no grid and with grid respectively. At each kilovoltage, the eNEQED and eDQE were between 10% and 70% larger when the grid was not used. The results show that 80 kV without grid is the most suitable exposure conditions for CR in chest. This is consistent with clinical practice in the UK and previous publications recommending a low kV technique for CR for average sized adult chest imaging.

  11. Assessment of maxillary third molars with panoramic radiography and cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yun Hoa; Cho, Bong Hae [Dept.of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yangsan (Korea, Republic of)

    2015-12-15

    This study investigated maxillary third molars and their relation to the maxillary sinus using panoramic radiography and cone-beam computed tomography (CBCT). A total of 395 maxillary third molars in 234 patients were examined using panoramic radiographs and CBCT images. We examined the eruption level of the maxillary third molars, the available retromolar space, the angulation, the relationship to the second molars, the number of roots, and the relationship between the roots and the sinus. Females had a higher frequency of maxillary third molars with occlusal planes apical to the cervical line of the second molar (Level C) than males. All third molars with insufficient retromolar space were Level C. The most common angulation was vertical, followed by buccoangular. Almost all of the Level C molars were in contact with the roots of the second molar. Erupted teeth most commonly had three roots, and completely impacted teeth most commonly had one root. The superimposition of one third of the root and the sinus floor was most commonly associated with the sinus floor being located on the buccal side of the root. Eruption levels were differently distributed according to gender. A statistically significant association was found between the eruption level and the available retromolar space. When panoramic radiographs showed a superimposition of the roots and the sinus floor, expansion of the sinus to the buccal side of the root was generally observed in CBCT images.

  12. Digital mammography with synchrotron radiation: characterization of a novel computed radiography system

    Science.gov (United States)

    Trivellato, S.; Vandenbroucke, D.; Arfelli, F.; Bessem, M.; Fedon, C.; Longo, R.; Tromba, G.; Taibi, A.

    2015-08-01

    Breast X-ray imaging is a continuous research field to define dedicated equipment, with specialized X-ray sources and efficient detectors to improve image quality with an equal or even lower patient dose. The Needle Imaging Plate HM5.0, produced by Agfa, has been characterized using synchrotron radiation to assess the performance of this novel imaging chain in comparison to conventional mammographic equipment. The detection performance has been initially assessed in terms of Detective Quantum Efficiency (DQE) and its computation showed that DQE curves are very close to the typical results for digital radiography systems. Image threshold contrast has been then evaluated using the CDMAM phantom. The analysis has been completed with a scoring of visible details in the radiographs of the TORMAM phantom. The characterization thus confirms that monochromaticity leads to an equal image quality with a lower glandular dose and phase-contrast effects lead to an increase in anatomical structure detectability. Finally, a preliminary evaluation of clinical images showed a clear improvement in image quality thanks to phase-contrast contribution and to detector performance.

  13. Comparison of periapical radiography with cone beam computed tomography in the diagnosis of vertical root fractures in teeth with metallic post.

    Science.gov (United States)

    Takeshita, Wilton Mitsunari; Iwaki, Lilian Cristina Vessoni; da Silva, Mariliani Chicarelli; Sabio, Sergio; Albino, Paulo Ricardo Febrairo

    2014-05-01

    To compare the diagnostic accuracy of conventional periapical radiography and cone beam computed tomography (CBCT) in detecting vertical root fracture (VRF) in tooth with metallic post (MP). Twenty endodontically-treated teeth received MPs, artificial fractures were created in 10 teeth, and they were all examined with tomography and radiography. The sample consisted of periapical radiography with post and without post, and tomography with post and without post; each group with five fractured and five non-fractured teeth. The images were evaluated by three dental/maxillofacial radiologists and statistical validations were carried out using receiver operating characteristic (ROC) analysis. Sensitivity and specificity of the area under the ROC (Az) of tomography with post (Az = 0.953) and without post (Az = 0.956) were significantly higher than those of periapical radiography with post (Az = 0.753) and without post (Az = 0.778). CBCT was more accurate than conventional periapical radiography in detecting VRF.

  14. Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects

    Directory of Open Access Journals (Sweden)

    Roghieh Bardal Bardal

    2016-08-01

    Full Text Available Objectives: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT and intraoral photostimulable phosphor plate (PSP digital and film-based conventional radiography for detection of artificial cancellous bone defects.Materials and Methods: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual, radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC analysis were determined for each observer.Results: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613. The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406. The area under the curve (AUC of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either.Conclusion: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills.

  15. Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects

    Science.gov (United States)

    Bardal, Roghieh; Jahanihashemi, Hassan; Mostafavi, Maryam; Kalhor, Esmaeil; Tofangchiha, Maryam; Dehghani, Mahdieh

    2015-01-01

    Objectives: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects. Materials and Methods: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer. Results: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either. Conclusion: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills. PMID:27507990

  16. Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2014-01-01

    Full Text Available Background: To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL. Materials and Methods: ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth - directly on the mandibles (control, using conventional periapical radiography with film holders (Rinn XCP and Han-Shin, digital periapical radiography with complementary metal-oxide semiconductor sensor, conventional panoramic, and cone-beam computed tomography (CBCT. Three programs were used to measure ABL on the images: Image tool 3.0 (University of Texas Health Sciences Center, San Antonio, Texas, USA, Kodak Imaging 6.1 (Kodak Dental Imaging 6.1, Carestream Health ® , Rochester, NY, USA, and i-CAT vision 1.6.20. Statistical analysis used ANOVA and Tukey′s test at 5% significance level. Results: The tomographic images showed the highest means, whereas the lowest were found for periapical with Han-Shin. Controls differed from periapical with Han-Shin (P < 0.0001. CBCT differed from panoramic (P = 0.0130, periapical with Rinn XCP (P = 0.0066, periapical with Han-Shin (P < 0.0001, and digital periapical (P = 0.0027. Conventional periapicals with film holders differed from each other (P = 0.0007. Digital periapical differed from conventional periapical with Han-Shin (P = 0.0004. Conclusions: Conventional periapical with Han-Shin film holder was the only method that differed from the controls. CBCT had the closest means to the controls.

  17. Comparison of Thoracic Radiography and Computed Tomography in Calves with Naturally Occurring Respiratory Disease

    Directory of Open Access Journals (Sweden)

    Jennifer Fowler

    2017-07-01

    Full Text Available ObjectiveTo evaluate the severity and extent of lung disease using thoracic computed radiography (CR compared to contrast-enhanced multi-detector computed tomography (MDCT of the thorax in calves with naturally occurring respiratory disease and to evaluate the feasibility and safety of performing contrast-enhanced thoracic multi-detector MDCT examinations in sedated calves. Furthermore, to evaluate if combining CR or MDCT with respiratory scoring factors will improve prediction of the chronicity of pulmonary disease in calves.AnimalsThirty Jersey heifer calves ranging in age between 25 and 89 days with naturally occurring respiratory disease.ProceduresAll calves were evaluated via thoracic CR and contrast-enhanced MDCT. All calves were euthanized immediately following thoracic MDCT and submitted for necropsy. Imaging and histopathology results were compared with each other.ResultsThoracic MDCT was superior for evaluation of pneumonia in calves due to the lack of summation in all areas of the lungs. Intravenously administered sedation provided an adequate plane of sedation for acquiring MDCT images of diagnostic quality, without the need for re-scanning. A diagnosis of pneumonia was made with equal rate on both thoracic CR and MDCT. Although mild differences in classification of lung pattern and extent of lung disease were seen when comparing an experienced and a less experienced evaluator, the overall differences were not statistically significant. The best intra- and inter-observer agreement was noted when evaluating the cranioventral aspects of the lungs in either modality. Clinical respiratory scoring is inadequate for diagnosing chronicity of pneumonia in calves with naturally occurring pneumonia.Conclusion and clinical importanceBoth imaging modalities allowed diagnosis of pneumonia in calves. The cranial ventral aspects of the lungs were most commonly affected. Thoracic CR and MDCT provided similar diagnostic effectiveness in diagnosing

  18. Comparison of Thoracic Radiography and Computed Tomography in Calves with Naturally Occurring Respiratory Disease.

    Science.gov (United States)

    Fowler, Jennifer; Stieger-Vanegas, Susanne M; Vanegas, Jorge A; Bobe, Gerd; Poulsen, Keith P

    2017-01-01

    To evaluate the severity and extent of lung disease using thoracic computed radiography (CR) compared to contrast-enhanced multi-detector computed tomography (MDCT) of the thorax in calves with naturally occurring respiratory disease and to evaluate the feasibility and safety of performing contrast-enhanced thoracic multi-detector MDCT examinations in sedated calves. Furthermore, to evaluate if combining CR or MDCT with respiratory scoring factors will improve prediction of the chronicity of pulmonary disease in calves. Thirty Jersey heifer calves ranging in age between 25 and 89 days with naturally occurring respiratory disease. All calves were evaluated via thoracic CR and contrast-enhanced MDCT. All calves were euthanized immediately following thoracic MDCT and submitted for necropsy. Imaging and histopathology results were compared with each other. Thoracic MDCT was superior for evaluation of pneumonia in calves due to the lack of summation in all areas of the lungs. Intravenously administered sedation provided an adequate plane of sedation for acquiring MDCT images of diagnostic quality, without the need for re-scanning. A diagnosis of pneumonia was made with equal rate on both thoracic CR and MDCT. Although mild differences in classification of lung pattern and extent of lung disease were seen when comparing an experienced and a less experienced evaluator, the overall differences were not statistically significant. The best intra- and inter-observer agreement was noted when evaluating the cranioventral aspects of the lungs in either modality. Clinical respiratory scoring is inadequate for diagnosing chronicity of pneumonia in calves with naturally occurring pneumonia. Both imaging modalities allowed diagnosis of pneumonia in calves. The cranial ventral aspects of the lungs were most commonly affected. Thoracic CR and MDCT provided similar diagnostic effectiveness in diagnosing pneumonia. However, MDCT provided better assessment of subtle details, which may

  19. Detection of bone erosions in rheumatoid arthritis wrist joints with magnetic resonance imaging, computed tomography and radiography

    DEFF Research Database (Denmark)

    Døhn, Uffe Møller; Ejbjerg, Bo J; Hasselquist, Maria

    2008-01-01

    BACKGROUND: The objectives of the present study were, with multidetector computed tomography (CT) as the reference method, to determine the performance of magnetic resonance imaging (MRI) and radiography for the detection of bone erosions in rheumatoid arthritis wrist bones, and to test whether m...... sensitivity and good specificity and accuracy for detection of erosions in rheumatoid arthritis and healthy wrist bones, while radiography showed very low sensitivity. The tested volumetric method was highly reproducible and correlated to scores of erosions....... of the Outcome Measures in Rheumatology Rheumatoid Arthritis MRI Scoring System (CT and MRI) and the Sharp/van der Heijde (radiographs) scoring methods. Measurements of erosion volumes of all erosions were performed twice with a 1-week interval. RESULTS: With CT as the reference method, the overall sensitivity.......90 (both P persons' total erosion volume and total score (all P

  20. Quantitative evaluation of anatomical noise in chest digital tomosynthesis, digital radiography, and computed tomography

    Science.gov (United States)

    Lee, D.; Choi, S.; Lee, H.; Kim, D.; Choi, S.; Kim, H.-J.

    2017-04-01

    Lung cancer is currently the worldwide leading cause of death from cancer. Thus, detection of lung cancer at its early stages is critical for improving the survival rate of patients. Chest digital tomosynthesis (CDT) is a recently developed imaging modality, combining many advantages of digital radiography (DR) and computed tomography (CT). This method has the potential to be widely used in the clinical setting. In this study, we introduce a developed CDT R/F system and compare its image quality with those of DR and CT, especially with respect to anatomical noise and lung nodule conspicuity, for LUNGMAN phantoms. The developed CDT R/F system consists of a CsI scintillator flat panel detector, X-ray tube, and tomosynthesis data acquisition geometry. For CDT R/F imaging, 41 projections were acquired at different angles, over the ± 20° angular range, in a linear translation geometry. To evaluate the clinical effectiveness of the CDT R/F system, the acquired images were compared with CT (Philips brilliance CT 64, Philips healthcare, U.S.) and DR (ADR-M, LISTEM, Korea) phantom images in terms of the anatomical noise power spectrum (aNPS). DR images exhibited low conspicuity for a small-size lung nodule, while CDT R/F and CT exhibited relatively high sensitivity for all lung nodule sizes. The aNPS of the CDT R/F system was better than that of DR, by resolving anatomical overlapping problems. In conclusion, the developed CDT R/F system is likely to contribute to early diagnosis of lung cancer, while requiring a relatively low patient dose, compared with CT.

  1. Extremity exams optimization for computed radiography; Otimizacao de exames de extremidade para radiologia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, Ana Luiza M.; Alves, Allan Felipe F.; Velo, Alexandre F.; Miranda, Jose Ricardo A., E-mail: analuiza@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias. Departamento de Fisica e Biofisica; Pina, Diana R. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Doencas Tropicais e Diagnostico por Imagem

    2013-08-15

    The computed radiography (CR) has become the most used device for image acquisition, since its introduction in the 80s. The detection and early diagnosis, obtained through CR examinations, are important for the successful treatment of diseases of the hand. However, the norms used for optimization of these images are based on international protocols. Therefore, it is necessary to determine letters of radiographic techniques for CR system, which provides a safe medical diagnosis, with doses as low as reasonably achievable. The objective of this work is to develop an extremity homogeneous phantom to be used in the calibration process of radiographic techniques. In the construction process of the simulator, it has been developed a tissues' algorithm quantifier using Matlab®. In this process the average thickness was quantified from bone and soft tissues in the region of the hand of an anthropomorphic simulator as well as the simulators' material thickness corresponding (aluminum and Lucite) using technique of mask application and removal Gaussian histogram corresponding to tissues of interest. The homogeneous phantom was used to calibrate the x-ray beam. The techniques were implemented in a calibrated hand anthropomorphic phantom. The images were evaluated by specialists in radiology by the method of VGA. Skin entrance surface doses were estimated (SED) corresponding to each technique obtained with their respective tube charge. The thicknesses of simulators materials that constitute the homogeneous phantom determined in this study were 19.01 mm of acrylic and 0.81 mm of aluminum. A better picture quality with doses as low as reasonably achievable decreased dose and tube charge around 53.35% and 37.78% respectively, compared normally used by radiology diagnostic routine clinical of HCFMB-UNESP. (author)

  2. An in vitro comparison of diagnostic abilities of conventional radiography, storage phosphor, and cone beam computed tomography to determine occlusal and approximal caries

    Energy Technology Data Exchange (ETDEWEB)

    Kayipmaz, Saadettin, E-mail: kayipmaz@ktu.edu.tr [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Diagnosis and Radiology, Farabi, 61080 Trabzon (Turkey); Sezgin, Omer Said, E-mail: omersaidsezgin@gmail.com [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Diagnosis and Radiology, Farabi, 61080 Trabzon (Turkey); Saricaoglu, Senem Tugra, E-mail: senem_tugra@hotmail.com [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Diagnosis and Radiology, Farabi, 61080 Trabzon (Turkey); Can, Gamze, E-mail: gcanktu@yahoo.com [Karadeniz Technical University Faculty of Medicine Department of Public Health (Turkey)

    2011-11-15

    Aim: The aim of this study was to compare conventional radiography, storage phosphor plate, and cone beam computed tomography for in vitro determination of occlusal and approximal caries. Methods: A total of 72 extracted human premolar and molar teeth were selected. Teeth were radiographed with conventional intraoral radiography, a storage phosphor plate system, and cone beam computed tomography and evaluated by two observers. The teeth were then separated and examined with a stereomicroscope and a scanner at approximately 8x magnification. Results: CBCT was statistically superior to conventional radiography and phosphor plate for determining occlusal caries. No significant difference from CBCT, conventional radiography and the phosphor plate system for determining approximal caries was found. Conclusion: The CBCT system may be used as an auxiliary method for the detection of caries.

  3. Improvement of the clinical use of computed radiography for mobile chest imaging: Image quality and patient dose

    Science.gov (United States)

    Rill, Lynn Neitzey

    Chest radiography is technically difficult because of the wide variation of tissue attenuations in the chest and limitations of screen-film systems. Mobile chest radiography, performed bedside on hospital inpatients, presents additional difficulties due to geometrical and equipment limitations inherent to mobile x-ray procedures and the severity of illness in patients. Computed radiography (CR) offers a new approach for mobile chest radiography by utilizing a photostimulable phosphor. Photostimulable phosphors are more efficient in absorbing lower-energy x-rays than standard intensifying screens and overcome some image quality limitations of mobile chest imaging, particularly because of the inherent latitude. This study evaluated changes in imaging parameters for CR to take advantage of differences between CR and screen-film radiography. Two chest phantoms, made of acrylic and aluminum, simulated x-ray attenuation for average-sized and large- sized adult chests. The phantoms contained regions representing the lungs, heart and subdiaphragm. Acrylic and aluminum disks (1.9 cm diameter) were positioned in the chest regions to make signal-to-noise ratio (SNR) measurements for different combinations of imaging parameters. Disk thicknesses (contrast) were determined from disk visibility. Effective dose to the phantom was also measured for technique combinations. The results indicated that using an anti-scatter grid and lowering x- ray tube potential improved the SNR significantly; however, the dose to the phantom also increased. An evaluation was performed to examine the clinical applicability of the observed improvements in SNR. Parameter adjustments that improved phantom SNRs by more than 50% resulted in perceived image quality improvements in the lung region of clinical mobile chest radiographs. Parameters that produced smaller improvements in SNR had no apparent effect on clinical image quality. Based on this study, it is recommended that a 3:1 grid be used for

  4. The detection and management of root resorption lesions using intraoral radiography and cone beam computed tomography - an in vivo investigation.

    Science.gov (United States)

    Patel, S; Dawood, A; Wilson, R; Horner, K; Mannocci, F

    2009-09-01

    To compare the accuracy of intraoral periapical radiography with cone beam computed tomography (CBCT) for the detection and management of resorption lesions. Digital intraoral radiographs and CBCT scans were taken of patients with internal resorption (n = 5), external cervical resorption (n = 5) and no resorption (controls) (n = 5). A 'reference standard' diagnosis and treatment plan was devised for each tooth. Sensitivity, specificity, positive predictive values, negative predictive values and receiver operator characteristic (ROC) curves, as well as the reproducibility of each technique were determined for diagnostic accuracy and treatment option chosen. The intraoral radiography ROC Az values were 0.780 and 0.830 for diagnostic accuracy of internal and external cervical resorption respectively. The CBCT ROC Az values were 1.000 for both internal and external cervical resorption. There was a significantly higher prevalence (P = 0.028) for the correct treatment option being chosen with CBCT (%) compared with intraoral radiographs (%). CBCT was effective and reliable in detecting the presence of resorption lesions. Although digital intraoral radiography resulted in an acceptable level of accuracy, the superior accuracy of CBCT may result in a review of the radiographic techniques used for assessing the type of resorption lesion present. CBCT's superior diagnostic accuracy also resulted in an increased likelihood of correct management of resorption lesions.

  5. Diagnostic Value of Cone-Beam Computed Tomography and Periapical Radiography In Detection of Vertical Root Fracture

    Science.gov (United States)

    Ezzodini Ardakani, Fatemeh; Razavi, Seyed Hossein; Tabrizizadeh, Mehdi

    2015-01-01

    Introduction: Vertical root fracture (VRF) is the longitudinal fracture of the root in endodontically treated teeth. Considering the limitations of two-dimensional radiographic images in detection of VRF and introduction of cone-beam computed tomography (CBCT), this study was designed to find the sensitivity, specificity and accuracy of CBCT and periapical (PA) radiography in detection of VRFs. Methods and Materials: This was a cross-sectional in vitro study on 80 extracted human single canal teeth including 40 maxillary and 40 mandibular teeth. After standardized endodontic treatment of the roots, VRF was induced in half of the teeth in each group, and other half were left without fracture. Teeth were inserted in dry maxillary and mandibular alveoli. PA radiographs and CBCT images were taken from the specimens. Data were analyzed with SPSS software. The McNemar test was used to evaluate the sensitivity, specificity and accuracy of images, and kappa coefficient was used to assess the degree of agreement between the observers. The level of significance was set at 0.05. Results: Sensitivity and specificity values of CBCT were 97.5% and 95%, respectively. However, for PA radiography the sensitivity and specificity were 67.5% and 92.5%, in order of appearance. Accuracy of CBCT (96.25%) and PA radiography (80%) in both jaws were significantly different (P=0.022). Two methods were not significantly different when testing specificity (P=0.298). Conclusion: This study showed that the sensitivity and accuracy of CBCT in detection of vertical root fracture are higher than periapical radiography. CBCT can be recommended to be used in detection of vertical root fractures. PMID:25834597

  6. Chest radiography and thoracic computed tomography findings in children who have family members with active pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Uzum, Kazim; Karahan, Okkes I.; Dogan, Sukru; Coskun, Abdulhakim E-mail: coskuna@erciyes.edu.tr; Topcu, Faik

    2003-12-01

    Objective: The chest radiography and TCT findings in children who had contacted with adult family members with active pulmonary tuberculosis were compared. The contributions of thoracic computed tomography to the diagnosis of tuberculosis were investigated. Methods and material: The children who were 0-16 years old (n=173) and children of families with an adult member which was diagnosed as pulmonary tuberculosis were evaluated. The children were considered in two groups based on the absence (n=125) or presence (n=48) of complaints and/or ambiguous symptoms such as lack of appetite, mild cough, sweating, history of lung infection, low body weight and those with suspicious chest radiography findings (12 cases) were included in this study. Asymptomatic patients (n=125) did not undergo TCT. Patients who had positive PPD skin tests only received isoniazid. If the TCT demonstrated enlarged lymph nodes or parenchymal lesions, minimally active pulmonary tuberculosis was diagnosed and antituberculous treatment was given. Results and discussions: TCT revealed lymph node enlargement or parenchymal lesions in 39 children (81.2%). Of the 12 children whose CXRs revealed suspicious lymph node enlargement and/or infiltration, five had normal findings in TCT whereas the initial findings were confirmed in the remaining seven. These data suggest that there is a correlation between the presence of ambiguous symptoms in exposed children and TCT findings; chest radiography and TCT findings do not yield parallel findings. All the patients who received anti-TB treatment were resolved in the control examinations. Conclusion: In this study there is a correlation between presence of ambiguous symptoms and TCT findings, but the chest radiography and TCT findings do not yield harmony in exposed children with ambiguous symptoms (suspicious tuberculosis cases). These observations should be considered in children with symptoms similar to those of exposed children, but with no definite history of

  7. Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss

    OpenAIRE

    Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Renata Hernandes Tonin

    2014-01-01

    Background: To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL). Materials and Methods: ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth - directly on the mandibles (control), using conventional periapical radiography with film holders (Rinn XCP and Han-Shin), digital periapical radiography with complementary metal-oxide semiconductor sensor, conventional...

  8. Pulmonary Valve Anatomy and Abnormalities: A Pictorial Essay of Radiography, Computed Tomography (CT), and Magnetic Resonance Imaging (MRI).

    Science.gov (United States)

    Jonas, Samuel N; Kligerman, Seth J; Burke, Allen P; Frazier, Aletta Ann; White, Charles S

    2016-01-01

    Given its inconspicuous appearance on radiography, computed tomography (CT), and magnetic resonance imaging (MRI) the pulmonary valve (PV) is often overlooked as an important cause of both cardiac and pulmonary disease. In this pictorial essay, we review the normal appearance of the PV as well as various congenital anomalies including pulmonary atresia, pulmonary stenosis, and valvular fusion anomalies. Infectious entities, degenerative conditions, and malignant lesions are also depicted. We discuss surgical techniques used to repair both congenital and acquired pulmonary valvular diseases and describe postoperative appearances of the PV on imaging.

  9. Finding-specific display presets for computed radiography soft-copy reading.

    Science.gov (United States)

    Andriole, K P; Gould, R G; Webb, W R

    1999-05-01

    Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding

  10. Three-dimensional biplanar radiography as a new means of accessing femoral version: a comparitive study of EOS three-dimensional radiography versus computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pomerantz, M.L. [University of California San Diego School of Medicine, Orthopaedic Surgery Department, San Diego, CA (United States); Glaser, Diana [Aurora Spine, Carlsbad, CA (United States); Doan, Josh [Orthopedic Biomechanics Research Center, San Diego, CA (United States); Kumar, Sita [University of California, San Diego, CA (United States); Edmonds, Eric W. [University of California San Diego School of Medicine, Orthopaedic Surgery Department, San Diego, CA (United States); Rady Children' s Hospital San Diego, Division of Orthopedic Surgery, San Diego, CA (United States)

    2014-10-17

    To validate femoral version measurements made from biplanar radiography (BR), three-dimensional (3D) reconstructions (EOS imaging, France) were made in differing rotational positions against the gold standard of computed tomography (CT). Two cadaveric femurs were scanned with CT and BR in five different femoral versions creating ten total phantoms. The native version was modified by rotating through a mid-diaphyseal hinge twice into increasing anteversion and twice into increased retroversion. For each biplanar scan, the phantom itself was rotated -10, -5, 0, +5 and +10 . Three-dimensional CT reconstructions were designated the true value for femoral version. Two independent observers measured the femoral version on CT axial slices and BR 3D reconstructions twice. The mean error (upper bound of the 95 % confidence interval), inter- and intraobserver reliability, and the error compared to the true version were determined for both imaging techniques. Interobserver intraclass correlation for CT axial images ranged from 0.981 to 0.991, and the intraobserver intraclass correlation ranged from 0.994 to 0.996. For the BR 3D reconstructions these values ranged from 0.983 to 0.998 and 0.982 to 0.998, respectively. For the CT measurements the upper bound of error from the true value was 5.4-7.5 , whereas for BR 3D reconstructions it was 4.0-10.1 . There was no statistical difference in the mean error from the true values for any of the measurements done with axial CT or BR 3D reconstructions. BR 3D reconstructions accurately and reliably provide clinical data on femoral version compared to CT even with rotation of the patient of up to 10 from neutral. (orig.)

  11. Evaluation Of Cone Beam Computed Tomography And Periapical Radiography In The Diagnosis Of Root Resorption.

    OpenAIRE

    Lima, Thiago Farias Rocha; Gamba, Thiago de Oliveira; Zaia, Alexandre Augusto; Soares,Adriana de Jesus

    2016-01-01

    This study aimed to evaluate the accuracy of CBCT and periapical radiography in diagnosing root resorption and verify the influence of filling material in detecting these lesions. Digital periapical radiographs and CBCT images of patients with root resorption and a history of dental trauma from a radiology clinic were reviewed retrospectively. The sample comprised 40 teeth with root resorption and 20 normal teeth as controls. Images were analyzed by two radiologists and two endodontists. The ...

  12. Accuracy of digital radiography and cone beam computed tomography on periapical radiolucency detection in endodontically treated teeth.

    Science.gov (United States)

    Venskutonis, Tadas; Daugela, Povilas; Strazdas, Marijus; Juodzbalys, Gintaras

    2014-04-01

    The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images) from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women) a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible) were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42) and radiographic (n = 24) examinations (P periapical lesions than with the radiographic method (P periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  13. Skeletal imaging following reconstruction of the posterior cruciate ligament: in vivo comparison of fluoroscopy, radiography, and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Osti, Michael; Benedetto, Karl Peter [Academic Hospital Feldkirch, Department for Trauma Surgery and Sports Traumatology, Feldkirch (Austria); Krawinkel, Alessa [Academic Hospital Feldkirch, Department for Radiology, Feldkirch (Austria)

    2014-12-15

    Intra- and postoperative validation of anatomic footprint replication in posterior cruciate ligament (PCL) reconstruction can be conducted using fluoroscopy, radiography, or computed tomography (CT) scans. However, effectiveness and exposure to radiation of these imaging modalities are unknown. The objective of this study was to evaluate the comparative effectiveness of fluoroscopy, radiography, and CT in detecting femoral and tibial tunnel positions following an all-inside reconstruction of the PCL ligament in vivo. The study design was a retrospective case series. Intraoperative fluoroscopic images, postoperative radiographs, and CT scans were obtained in 50 consecutive patients following single-bundle PCL reconstruction. The centers of the tibial and femoral tunnel apertures were identified and correlated to measurement grid systems. The results of fluoroscopic, radiographic, and CT measurements were compared to each other and accumulated radiation dosages were calculated. Comparing the imaging groups, no statistically significant difference could be detected for the reference of the femoral tunnel to the intercondylar depth and height, for the reference of the tibial tunnel to the mediolateral diameter of the tibial plateau and for the superoinferior distance of the tibial tunnel entry to the tibial plateau and to the former physis line. Effective doses resulting from fluoroscopic, radiographic, and CT exposure averaged 2.9 mSv, standard deviation (±SD) 4.1 mSv, to 1.3 ± 0.8 mSv and to 3.6 ± 1.0 mSv, respectively. Fluoroscopy, radiography, and CT yield approximately equal effectiveness in detecting parameters used for quality validation intra- and postoperatively. An accumulating exposure to radiation must be considered. (orig.)

  14. Dorsolateral subluxation of hip joints in dogs measured in a weight-bearing position with radiography and computed tomography.

    Science.gov (United States)

    Farese, J P; Todhunter, R J; Lust, G; Williams, A J; Dykes, N L

    1998-01-01

    develop a radiographic procedure to measure dorsolateral subluxation (DLS) of the femoral head in canine coxofemoral (hip) joints in a weight-bearing position. DLS measured on a radiographic projection was compared with DLS measured on computed tomography (CT) images of hip joints in a weight-bearing position. A total of 24 dogs of varying ages were examined including Labrador retrievers, greyhounds, and Labrador-greyhound crossbreeds. Anesthetized dogs were placed in sternal recumbency in a kneeling position in a foam rubber mold. The stifles were flexed and adducted with the femora perpendicular to, and in contact with, the table. To test for DLS, dogs were imaged in this weight-bearing position (DLS test) with routine radiography and CT. For each hip, the DLS score was determined by measuring the percentage of the femoral head medial to the lateralmost point of the cranial acetabular rim on the dorsoventral radiographic projection and the lateralmost point of the central, dorsal acetabular rim on the CT image. Higher DLS scores indicated better coverage of the femoral head by the acetabulum. DLS scores were compared with the distraction index (DI) by grouping joints according to their probability of developing osteoarthritis (OA) as predicted by the DI. The DLS score in the new position ranged from 29% to 71% for radiography and 15% to 59% for CT. Joints classified as OA unsusceptible had a mean score of 64% +/- 1.5% for radiography and 55% +/- 0.8% for CT (n = 10); hip joints having a high probability of developing OA had a score of 39% +/- 2.6% for radiography and 26% +/- 1.9% for CT (n = 8). When the DLS test was repeated on the same dogs at a different time, the intraclass correlation coefficient for the DLS score on the radiographs was 0.85 (left hip) and 0.89 (right hip). There was a strong correlation (r = .89 for both hips) between the DLS score measured on the weight-bearing radiograph and the CT image. A strong correlation also was observed between the

  15. Comparing intraoral radiography and computed tomography for detecting radiographic signs of periodontitis and endodontic disease in dogs: an agreement study.

    Directory of Open Access Journals (Sweden)

    Robert David Campbell

    2016-08-01

    Full Text Available Objective: To determine whether computed tomography and intraoral radiography are interchangeable for detecting signs of periodontitis and endodontic disease in dogs. Materials and Methods: An agreement study was performed using 40 dogs that previously underwent intraoral radiography and computed tomography during the same anesthetic episode. Images of each tooth were examined by two blinded observers for signs of periodontitis and/or endodontic disease. Agreement between imaging modalities and between observers was assessed using the Kappa statistic.Results: Agreement between modalities for detecting periodontitis in the maxillae ranged from poor to very good (κ 0.07-1.00 with 16/20 (80% of the teeth having a score of moderate or better (κ ≥ 0.41. Agreement between modalities for detecting signs consistent with periodontitis in the mandibles ranged from poor to very good (κ 0.01-1.00 with 10/22 (45% of the teeth having a score of good or better (κ ≥0.61; 50% of the disagreement was present in the incisors. Agreement between modalities for detecting signs consistent with endodontic disease in the whole mouth ranged from fair to very good (κ 0.21-1.00 with 30/42 (71% of the teeth having a score of moderate or better (κ ≥0.41. Agreement between observers evaluating IOR ranged from poor to very good (κ 0.05-1 for detecting signs consistent with periodontitis and from fair to very good (κ 0.36-1 for detecting signs consistent with endodontic disease, in the whole mouth. Agreement between observers evaluating CT ranged from fair to very good (κ 0.35-1 for detecting signs consistent with periodontitis and from fair to very good (κ 0.36-1 for detecting signs consistent with endodontic disease, in the whole mouth Conclusions: Performing both computed tomography and intraoral radiography may be unnecessary to detect signs consistent with periodontitis and endodontic disease in dogs based on the amount of agreement between modalities and

  16. Accuracy of Digital Radiography and Cone Beam Computed Tomography on Periapical Radiolucency Detection in Endodontically Treated Teeth

    Directory of Open Access Journals (Sweden)

    Tadas Venskutonis

    2014-07-01

    Full Text Available Objectives: The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Material and Methods: Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. Results: In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42 and radiographic (n = 24 examinations (P < 0.05. In molar teeth, CBCT identify a significantly higher amount of periapical lesions than with the radiographic method (P < 0.05. There were significant differences between CBCT and PR in the mean number of lesions identified per tooth (1.2 vs 0.66, P = 0.03, number of teeth with lesions (0.71 vs 0.46, P = 0.03 and number of lesions identified per canal (0.57 vs 0.33, P = 0.005. Considering CBCT as “gold standard” in lesion detection with the sensitivity, specificity and accuracy considering as score 1, then the same parameters of PR were 0.57, 1 and 0.76 respectively. Conclusions: Within the limitations of the present study, it can be concluded that cone beam computed tomography scans were more accurate compared to digital periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  17. Position of the impacted third molar in relation to the mandibular canal. Diagnostic accuracy of cone beam computed tomography compared with panoramic radiography.

    NARCIS (Netherlands)

    Ghaeminia, H.; Meijer, G.J.; Soehardi, A.; Borstlap, W.A.; Mulder, J.; Berge, S.J.

    2009-01-01

    This study investigated the diagnostic accuracy of cone beam computed tomography (CBCT) compared to panoramic radiography in determining the anatomical position of the impacted third molar in relation with the mandibular canal. The study sample comprised 53 third molars from 40 patients with an

  18. Control dose in chest radiography after the installation of the computed radiography; Control de dosis impartidas en radiografia de torax tras la instalacion de un sistema de radiografia computerizada

    Energy Technology Data Exchange (ETDEWEB)

    Minano Herrero, J. A.; Solar Cantos, M. M.; Roldan Arjona, J. M.; Martinez Cobos, R.

    2006-07-01

    The aim of this work is to verify patient does after the installation of the computed radiography. Entrance surface doses were obtained from a measurement of the output of the x-ray tube and exposure factor used at posteroanterior (PA) and lateral (LAT) chest in 50 adult patients before and after the installation. The obtained average values were 0.28{+-}0.10mGy in the PA view and 0.8{+-}0.5 mGy in the LAT view with the conventional screen-film system 0.27{+-}0.06 mGy in PA view and 0.69{+-}0.18 mGy in LAT view with the digital radiography system. The results do not exceed the diagnostic reference levels (DRLs) and are constant after the change of system. (Author)

  19. Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93.

    Science.gov (United States)

    Muhogora, Wilbroad; Padovani, Renato; Bonutti, Faustino; Msaki, Peter; Kazema, R

    2011-07-01

    The performances of three clinical computed radiography (CR) systems, (Agfa CR 75 (with CRMD 4.0 image plates), Kodak CR 850 (with Kodak GP plates) and Kodak CR 850A (with Kodak GP plates)) were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers' characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009) and for Kodak CR systems (P=0.006) probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284) suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly.

  20. Diagnostic Value of Panoramic Radiography, Cone Beam Computed Tomography (CBCT and Clinical Measurement in Determining Bone Dimensions

    Directory of Open Access Journals (Sweden)

    Amirreza Babaloo

    2015-07-01

    Full Text Available Introduction: Calculation of the bone dimensions is of great importance for implant treatment. Several radiographic modalities have been used for this purpose. This study compared the accuracy of mesiodistal measurements of bone using panoramic radiography, cone beam computed tomography (CBCT, and the clinical methods. Methods: In this descriptive cross-sectional study, panoramic and CBCT images were obtained from 100 implant patients. Mesiodistal bone dimensions (distance between tooth CEJ in the mesial of edentulous region and CEJ of the tooth in distal of edentulous region were calculated using a scaled ruler on the orthopantomograms and the system software in the CBCT images. During the implant insertions, a mucoperiosteal flap was raised and clinical dimensions of the bone were measured by a periodontal probe and bone gauge. The differences of bone height and thickness measurements between gold standard and CBCT or panoramic modalities were analyzed using Student’s t- test. Results: The mean bone height was 10.64±1.55, 11.44±1.51, and 10.68±1.6 mm in the clinical, panoramic and CBCT modalities, respectively. Statistically significant difference was noted between the clinical and panoramic techniques (P0.05. During the bone height calculations, 79%, 62% and 78% of the images were ranked in the normal range using CBCT, panoramic and gold standard measurements, respectively. The mean areas under the ROC curve were 0.92 and 0.83 in CBCT and panoramic techniques, respectively. Conclusion: Accuracy of the CBCT images was higher than panoramic technique in measuring the bone dimensions and this technique can be confidently used to calculate the bone dimensions for the implant surgeries.   Keywords: Partially edentulous jaw; panoramic radiography; cone-beam computed tomography; bone dimensions

  1. Automatic exposure control calibration and optimisation for abdomen, pelvis and lumbar spine imaging with an Agfa computed radiography system

    Science.gov (United States)

    Moore, C. S.; Wood, T. J.; Avery, G.; Balcam, S.; Needler, L.; Joshi, H.; Saunderson, J. R.; Beavis, A. W.

    2016-11-01

    The use of three physical image quality metrics, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm) have recently been examined by our group for their appropriateness in the calibration of an automatic exposure control (AEC) device for chest radiography with an Agfa computed radiography (CR) imaging system. This study uses the same methodology but investigates AEC calibration for abdomen, pelvis and spine CR imaging. AEC calibration curves were derived using a simple uniform phantom (equivalent to 20 cm water) to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated abdomen, pelvis and spine images (created from real patient CT datasets) with appropriate detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated images contained clinically realistic projected anatomy and were scored by experienced image evaluators. Constant DDI and CNR curves did not provide optimized performance but constant eNEQm and SNR did, with the latter being the preferred calibration metric given that it is easier to measure in practice. This result was consistent with the previous investigation for chest imaging with AEC devices. Medical physicists may therefore use a simple and easily accessible uniform water equivalent phantom to measure the SNR image quality metric described here when calibrating AEC devices for abdomen, pelvis and spine imaging with Agfa CR systems, in the confidence that clinical image quality will be sufficient for the required clinical task. However, to ensure appropriate levels of detector air kerma the advice of expert image evaluators must be sought.

  2. Fast scanning tomosynthesis for the detection of pulmonary nodules: diagnostic performance compared with chest radiography, using multidetector-row computed tomography as the reference.

    Science.gov (United States)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hasegawa, Ichiro; Shiomi, Eisuke; Sugiura, Hiroaki; Abe, Takayuki; Sato, Yuji; Kuribayashi, Sachio; Ogawa, Kenji

    2011-08-01

    : To evaluate the diagnostic performance of fast scanning tomosynthesis in comparison with that of chest radiography for the detection of pulmonary nodules, using multidetector-row computed tomography (MDCT) as the reference, and to assess the association of the true-positive fraction (TPF) with the size, CT attenuation value, and location of the nodules. : The institutional review board approved this study, and written informed consent was obtained from all patients. Fifty-seven patients with and 59 without pulmonary nodules underwent chest MDCT, fast scanning tomosynthesis, and radiography. The images of tomosynthesis and radiography were randomly read by 3 blinded radiologists; MDCT served as the reference standard. Free-response receiver-operating characteristic (FROC) and receiver-operating characteristic (ROC) analyses, Cochran-Armitage trend or Fisher exact test, a conditional logistic regression model, and McNemar test were used. : Both FROC and ROC analyses revealed significantly better performance (P performance of fast scanning tomosynthesis for the detection of pulmonary nodules was significantly superior to that of radiography. The TPF was affected by the size, CT attenuation value, and location of the nodule, in both fast scanning tomosynthesis and radiography.

  3. Comparative of radiation dose and image quality of Conventional Multislice Computed Tomography (MSCT, Cone-Beam CT (CBCT and periapical radiography in dental imaging

    Directory of Open Access Journals (Sweden)

    Nasrollah Jabbari

    2016-03-01

    Full Text Available Background and Aims: With the increasing use of CT (Computed Tomoghraphy scans in dentistry especially in the implantology, there may be significant increases in the radiation exposure and its risk. During the last year’s ConeBeam Computed Tomoghraphy (CBCT has been introduced as an imaging modality for dentistry. The aim of this review article was to present comprehensive information have been published, regarding the  radiation dose and image quality of Conventional Multislice Computed Tomography (MSCT, Cone-Beam CT (CBCT and periapical radiography in dentistry imaging. Materials and Methods: A review of the literature was carried out in PubMed, Google Scholar, Science Direct and Scopus database using key words (CBCT, MSCT, periapical radiography, radiation dose of dentistry and image quality. These searches were limited to the articles published between the years of 1993 to 2015. Conclusion: In comparison to MSCT, CBCT had a short scanning times and lower radiation dose, but in comparison to periapical radiography, CBCT had higher radiation dose. In contrast, CBCT with flat panel detector had higher spatial resolution to MSCT. The periapical radiography also had a good image contrast and relatively high resolution. Generally, CBCT was suitable for hard tissue imaging and MSCT was preferred for soft tissue imaging.

  4. Comparing Intraoral Radiography and Computed Tomography for Detecting Radiographic Signs of Periodontitis and Endodontic Disease in Dogs: An Agreement Study.

    Science.gov (United States)

    Campbell, Robert D; Peralta, Santiago; Fiani, Nadine; Scrivani, Peter V

    2016-01-01

    To determine whether computed tomography (CT) and intraoral radiography are interchangeable for detecting signs of periodontitis and endodontic disease in dogs. An agreement study was performed using 40 dogs that previously underwent intraoral radiography and CT during the same anesthetic episode. Images of each tooth were examined by two blinded observers for signs of periodontitis and/or endodontic disease. Agreement between imaging modalities and between observers was assessed using the Kappa statistic. Agreement between modalities for detecting periodontitis in the maxillae ranged from poor to very good (κ 0.07-1.00) with 16/20 (80%) of the teeth having a score of moderate or better (κ ≥ 0.41). Agreement between modalities for detecting signs consistent with periodontitis in the mandibles ranged from poor to very good (κ 0.01-1.00) with 10/22 (45%) of the teeth having a score of good or better (κ ≥ 0.61); 50% of the disagreement was present in the incisors. Agreement between modalities for detecting signs consistent with endodontic disease in the whole mouth ranged from fair to very good (κ 0.21-1.00) with 30/42 (71%) of the teeth having a score of moderate or better (κ ≥ 0.41). Agreement between observers evaluating intraoral radiology ranged from poor to very good (κ 0.05-1) for detecting signs consistent with periodontitis and from fair to very good (κ 0.36-1) for detecting signs consistent with endodontic disease, in the whole mouth. Agreement between observers evaluating CT ranged from fair to very good (κ 0.35-1) for detecting signs consistent with periodontitis and from fair to very good (κ 0.36-1) for detecting signs consistent with endodontic disease, in the whole mouth. Performing both CT and intraoral radiography may be unnecessary to detect signs consistent with periodontitis and endodontic disease in dogs based on the amount of agreement between modalities and observers when CT images are acquired and reconstructed

  5. Diagnostic Accuracy of Periapical Radiography and Cone-beam Computed Tomography in Identifying Root Canal Configuration of Human Premolars.

    Science.gov (United States)

    Sousa, Thiago Oliveira; Haiter-Neto, Francisco; Nascimento, Eduarda Helena Leandro; Peroni, Leonardo Vieira; Freitas, Deborah Queiroz; Hassan, Bassam

    2017-07-01

    The aim of this study was to assess the diagnostic accuracy of periapical radiography (PR) and cone-beam computed tomographic (CBCT) imaging in the detection of the root canal configuration (RCC) of human premolars. PR and CBCT imaging of 114 extracted human premolars were evaluated by 2 oral radiologists. RCC was recorded according to Vertucci's classification. Micro-computed tomographic imaging served as the gold standard to determine RCC. Accuracy, sensitivity, specificity, and predictive values were calculated. The Friedman test compared both PR and CBCT imaging with the gold standard. CBCT imaging showed higher values for all diagnostic tests compared with PR. Accuracy was 0.55 and 0.89 for PR and CBCT imaging, respectively. There was no difference between CBCT imaging and the gold standard, whereas PR differed from both CBCT and micro-computed tomographic imaging (P < .0001). CBCT imaging was more accurate than PR for evaluating different types of RCC individually. Canal configuration types III, VII, and "other" were poorly identified on CBCT imaging with a detection accuracy of 50%, 0%, and 43%, respectively. With PR, all canal configurations except type I were poorly visible. PR presented low performance in the detection of RCC in premolars, whereas CBCT imaging showed no difference compared with the gold standard. Canals with complex configurations were less identifiable using both imaging methods, especially PR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

    Energy Technology Data Exchange (ETDEWEB)

    Haghanifar, Sina; Moudi, Ehsan; Mesgarani, Abbas; Abbaszadeh, Naghi [Dental Material Research Center, Dental Faculty, Babol University of Medical Sciences, Babol (Iran, Islamic Republic of); Bijani, Ali [Non-Communicable Pediatric Diseases Research Center, Babol University of Medical Sciences, Babol (Iran, Islamic Republic of)

    2014-06-15

    The aim of this in vitro study was to determine the sensitivity and specificity of cone-beam computed tomography (CBCT) and digital periapical radiography in the detection of mesial root perforations of mandibular molars. In this in vitro study, 48 mandibular molars were divided into 4 groups. First, the mesial canals of all the 48 teeth were endodontically prepared. In 2 groups (24 teeth each), the roots were axially perforated in the mesiolingual canal 1-3 mm below the furcation region, penetrating the root surface ({sup r}oot perforation{sup )}. Then, in one of these 2 groups, the mesial canals were filled with gutta-percha and AH26 sealer. Mesial canals in one of the other 2 groups without perforation (control groups) were filled with the same materials. The CBCT and periapical radiographs with 3 different angulations were evaluated by 2 oral and maxillofacial radiologists. The specificity and sensitivity of the two methods were calculated, and P<0.05 was considered significant. The sensitivity and specificity of CBCT scans in the detection of obturated root canal perforations were 79% and 96%, respectively, and in the case of three-angled periapical radiographs, they were 92% and 100%, respectively. In non-obturated root canals, the sensitivity and specificity of CBCT scans in perforation detection were 92% and 100%, respectively, and for three-angled periapical radiographs, they were 50% and 96%, respectively. For perforation detection in filled-root canals, periapical radiography with three different horizontal angulations would be trustworthy, but it is recommended that CBCT be used for perforation detection before obturating root canals.

  7. Computed radiography plus rhythm software platform for FAC inspection in nuclear secondary circuit

    Energy Technology Data Exchange (ETDEWEB)

    Koetz, A.; Delannoy, L. [GE Sensing and Inspection Technologies, Skaneateles (United States); Knook, T. [EDF DTG, Grenoble (France)

    2011-07-01

    This paper will cover determining and ensuring proper follow up of Flow Accelerated Corrosion (FAC) in secondary circuit of Nuclear Power Plant using digital radiography. What are the relevant parameters on the pipes and weld wall thickness reading. How precise and reliable are the data and how best to record and archive. One challenge always faced with inspections is how to share the data and gain expert opinion when the expert is on-site; with digital inspection data and the use of software tools this challenge can be overcome. As you begin to collect all the inspection data the true 'power of the data' can be unfolded. Archiving of digital inspection data provides the foundation of asset management, allowing you to look at trends over time throughout inspection results done in one plant or multiple locations around the world. This document describes the process and results of tests performed through digital radiographic technic for the detection and sizing of thickness losses in weld roots areas. The tests were performed according to a pre-established program including a phase of testing on standard blocks and tubes and a phase of testing on components with real defects. (authors)

  8. Influence of estrogen deficiency and tibolone therapy on trabecular and cortical bone evaluated by computed radiography system in rats

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ana Carolina Bergmann de; Henriques, Helene Nara [Postgraduate Program in Pathology, Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Fernandes, Gustavo Vieira Oliveira [Postgraduate Program in Medical Sciences, Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Lima, Inaya; Oliveira, Davi Ferreira de; Lopes, Ricardo Tadeu [Nuclear Engineering Program, Federal University of Rio de Janeiro (UFRJ), RJ (Brazil); Pantaleao, Jose Augusto Soares [Maternal and Child Department, Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Granjeiro, Jose Mauro [Department of Cellular and Molecular Biology, Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Silva, Maria Angelica Guzman [Department of Pathology, Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2012-03-15

    Purpose: To verify the effects of tibolone administration on trabecular and cortical bone of ovariectomized female rats by computed radiography system (CRS). Methods: The experiment was performed on two groups of rats previously ovariectomized, one received tibolone (OVX+T) while the other did not (OVX), those groups were compared to a control group (C) not ovariectomized. Tibolone administration (1 mg/day) began thirty days after the ovariectomy and the treatment remained for five months. At last, the animals were euthanized and femurs and tibias collected. Computed radiographs of the bones were obtained and the digital images were used to determine the bone optical density and cortical thickness on every group. All results were statistically evaluated with significance set at P<0.05%. Results: Tibolone administration was shown to be beneficial only in the densitometric analysis of the femoral head, performing higher optical density compared to OVX. No difference was found in cortical bone thickness. Conclusion: Ovariectomy caused bone loss in the analyzed regions and tibolone administered in high doses over a long period showed not to be fully beneficial, but preserved bone mass in the femoral head. (author)

  9. Noninferiority and Equivalence Evaluation of Clinical Performance among Computed Radiography, Film, and Digitized Film for Telemammography Services

    Directory of Open Access Journals (Sweden)

    Antonio J. Salazar

    2016-01-01

    Full Text Available Objective. The aim of this study was to evaluate and compare the clinical performance of different alternatives to implement low-cost screening telemammography. We compared computed radiography, film printed images, and digitized films produced with a specialized film digitizer and a digital camera. Material and Methods. The ethics committee of our institution approved this study. We assessed the equivalence of the clinical performance of observers for cancer detection. The factorial design included 70 screening patients, four technological alternatives, and cases interpreted by seven radiologists, for a total of 1,960 observations. The variables evaluated were the positive predictive value (PPV, accuracy, sensitivity, specificity, and the area under the receiver operating characteristic curves (AUC. Result. The mean values for the observed variables were as follows: accuracy ranged from 0.77 to 0.82, the PPV ranged from 0.67 to 0.68, sensitivity ranged from 0.64 to 0.74, specificity ranged from 0.87 to 0.90, and the AUC ranged from 0.87 to 0.90. At a difference of 0.1 to claim equivalence, all alternatives were equivalent for all variables. Conclusion. Our findings suggest that telemammography screening programs may be provided to underserved populations at a low cost, using a film digitizer or a digital camera.

  10. Long-term evaluation of apical root resorption after orthodontic treatment using periapical radiography and cone beam computed tomography.

    Science.gov (United States)

    de Freitas, Jairo Curado; Lyra, Olavo César Porto; de Alencar, Ana Helena Gonçalves; Estrela, Carlos

    2013-01-01

    To evaluate the frequency of Apical Root Resorption (ARR) after orthodontic treatment at 52-288 months using periapical radiography (PR) and cone beam computed tomography (CBCT). Radiographic images obtained from 58 patients, before (T1) and after orthodontic treatment (T2), and following 52-288 months of treatment were analyzed by three members of the Brazilian Board of Orthodontics. Apical structures were evaluated by PR images (T2 and T3), using Levander and Malmgren scores. The presence of ARR on CBCT images was detected only at T3. The Kolmogorov-Smirnov test was used for statistical analyses, and the level of significance was set at 5%. Kappa statistics determined interobserver agreement. The more frequent ARR were with scores 1 in T2 (51.6%) and T3 (53.1%), when evaluated by PR (p > 0.05). When compared the frequencies of ARR in T3 among PR and CBCT images, the differences were significant for maxillary and mandibular premolar groups, and for mandibular molar group (p > 0.05). The teeth with highest frequency of ARR presence using CBCT images were maxillary lateral incisors (94.5%) and mandibular central incisors (87.7%), while the premolars showed the lowest frequency. The CBCT images showed that the teeth involved in orthodontic treatment with extraction present higher ARR frequency (p < 0.05). PR showed more frequency of ARR in posterior teeth groups when compared with CBCT images. ARR did not change in long-term post treatment.

  11. Comparison of intraoral radiography and cone-beam computed tomography for the detection of periodontal defects: an in vitro study.

    Science.gov (United States)

    Bagis, Nilsun; Kolsuz, Mehmet Eray; Kursun, Sebnem; Orhan, Kaan

    2015-05-28

    This study aimed to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) unit with digital intraoral radiography technique for detecting periodontal defects. The study material comprised 12 dry skulls with maxilla and mandible. Artificial defects (dehiscence, tunnel, and fenestration) were created on anterior, premolar and molar teeth separately using burs. In total 14 dehiscences, 13 fenestrations, eight tunnel and 16 without periodontal defect were used in the study. These were randomly created on dry skulls. Each teeth with and without defects were images at various vertical angles using each of the following modalities: a Planmeca Promax Cone Beam CT and a Digora photostimulable phosphor plates. Specificity and sensitivity for assessing periodontal defects by each radiographic technique were calculated. Chi-square statistics were used to evaluate differences between modalities. Kappa statistics assessed the agreement between observers. Results were considered significant at P < 0.05. The kappa values for inter-observer agreement between observers ranged between 0.78 and 0.96 for the CBCT, and 0.43 and 0.72 of intraoral images. The Kappa values for detecting defects on anterior teeth was the least, following premolar and molar teeth both CBCT and intraoral imaging. CBCT has the highest sensitivity and diagnostic accuracy for detecting various periodontal defects among the radiographic modalities examined.

  12. Comparative examinations of serum pepsinogen I, II and gastric area using computed radiography in the atrophic gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Tatsu, Yoshimitsu; Ogura, Yasuharu; Yamazaki, Kouichi [Osaka Medical Coll., Takatsuki (Japan)] [and others

    1995-11-01

    The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II value tended to decrease. In conclusion, as a relationship between the atrophic change and the serum PG levels had a wide variation, we considered it to be difficult to understand the presence and extent of the atrophic gastritis by measuring serum PG levels. (author).

  13. Characterization of a Silicon Strip Detector and a YAG:Ce Calorimeter for a Proton Computed Radiography Apparatus

    Science.gov (United States)

    Menichelli, David; Bruzzi, Mara; Bucciolini, Marta; Candiano, Giuliana; Pablo Cirrone, Giuseppe A.; Capineri, Lorenzo; Civinini, Carlo; Cuttone, Giacomo; Lo Presti, Domenico; Marrazzo, Livia; Pallotta, Stefania; Randazzo, Nunzio; Sipala, Valeria; Talamonti, Cinzia; Valentini, Samuela; Pieri, Stefano; Reggioli, Valentina; Brianzi, Mirko; Tesi, Mauro

    2010-02-01

    Today, there is a steadily growing interest in the use of proton beams for tumor therapy, as they permit to tightly shape the dose delivered to the target reducing the exposure of the surrounding healthy tissues. Nonetheless, accuracy in the determination of the dose distribution in proton-therapy is up to now limited by the uncertainty in stopping powers, which are presently calculated from the photon attenuation coefficients measured by X-ray tomography. Proton computed tomography apparatus (pCT) has been proposed to directly measure the stopping power and reduce this uncertainty. Main problem with proton imaging is the blurring effect introduced by multiple Coulomb scattering: single proton tracking is a promising technique to face this difficulty. As a first step towards a pCT system, we designed a proton radiography (pCR) prototype based on a silicon microstrip tracker (to characterize particle trajectories) and a segmented YAG:Ce calorimeter (to measure their residual energy). Aim of the system is to detect protons with a 1 MHz particle rate of and with kinetic energy in the range 250-270 MeV, high enough to pass through human body. Design and development of the pCR prototype, as well as the characterization of its single components, are described in this paper.

  14. Evaluation of the diagnostic accuracy of four-view radiography and conventional computed tomography analysing sacral and pelvic fractures in dogs.

    Science.gov (United States)

    Stieger-Vanegas, S M; Senthirajah, S K J; Nemanic, S; Baltzer, W; Warnock, J; Bobe, G

    2015-01-01

    The purpose of our study was (1) to determine whether four-view radiography of the pelvis is as reliable and accurate as computed tomography (CT) in diagnosing sacral and pelvic fractures, in addition to coxofemoral and sacroiliac joint subluxation or luxation, and (2) to evaluate the effect of the amount of training in reading diagnostic imaging studies on the accuracy of diagnosing sacral and pelvic fractures in dogs. Sacral and pelvic fractures were created in 11 canine cadavers using a lateral impactor. In all cadavers, frog-legged ventro-dorsal, lateral, right and left ventro-45°-medial to dorsolateral oblique frog leg ("rollover 45-degree view") radiographs and a CT of the pelvis were obtained. Two radiologists, two surgeons and two veterinary students classified fractures using a confidence scale and noted the duration of evaluation for each imaging modality and case. The imaging results were compared to gross dissection. All evaluators required significantly more time to analyse CT images compared to radiographic images. Sacral and pelvic fractures, specifically those of the sacral body, ischiatic table, and the pubic bone, were more accurately diagnosed using CT compared to radiography. Fractures of the acetabulum and iliac body were diagnosed with similar accuracy (at least 86%) using either modality. Computed tomography is a better method for detecting canine sacral and some pelvic fractures compared to radiography. Computed tomography provided an accuracy of close to 100% in persons trained in evaluating CT images.

  15. Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.

    Science.gov (United States)

    Durack, C; Patel, S; Davies, J; Wilson, R; Mannocci, F

    2011-02-01

    To compare in an ex vivo model the ability of digital intraoral radiography and cone beam computed tomography (CBCT) to detect simulated external inflammatory root resorption lesions, and to investigate the effect of altering the degree of rotation of the CBCT scanners X-ray source and imaging detector on the ability to detect the same lesions. Small and large simulated external inflammatory resorption (EIR) lesions were created on the roots of 10 mandibular incisor teeth from three human mandibles. Small volume CBCT scans with 180° and 360° of X-ray source rotation and periapical radiographs, using a digital photostimulable phosphor plate system, were taken prior to and after the creation of the EIR lesions. The teeth were relocated in their original sockets during imaging. Receiver operator characteristic (ROC) analysis and kappa tests of the reproducibility of the imaging techniques were carried out and sensitivity, specificity, positive and negative predictive values (PPV and NPV) were also determined for each technique. The overall area under the ROC curve (Az value) for intraoral radiography was 0.665, compared to Az values of 0.984 and 0.990 for 180° and 360° CBCT, respectively (Pintraoral radiography (Pradiography. The intra- and inter-examiner agreement was significantly better for CBCT than it was for intraoral radiography (Pintraoral periapical radiography. Small volume CBCT operating with 360° of rotation of the X-ray source and detector is no better at detecting small, artificially created EIR cavities than the same device operating with 180° of rotation. © 2010 International Endodontic Journal.

  16. Detection of vertical root fractures in the presence of intracanal metallic post: a comparison between periapical radiography and cone-beam computed tomography.

    Science.gov (United States)

    Junqueira, Rafael Binato; Verner, Francielle Silvestre; Campos, Celso Neiva; Devito, Karina Lopes; do Carmo, Antônio Márcio Resende

    2013-12-01

    This in vitro study compared cone-beam computed tomography (CBCT) exam with different voxel sizes with digital periapical radiography in the detection of vertical root fractures in teeth with and without intracanal metallic posts. Eighteen single-rooted human teeth were endodontically treated, prepared for cast metal posts, and artificially fractured. After positioning the teeth in dry mandibular sockets, the samples were subjected twice (with and without posts) to digital periapical radiography at 3 different angles and to CBCT examinations with 2 voxel sizes, 0.125 and 0.25 mm. The images were evaluated by 3 oral radiologists. Indices of sensitivity, specificity, and positive and negative predictive values, in addition to the areas under the receiver operating characteristic curves (accuracy), were calculated. Comparison of the accuracy of the imaging methods was assessed by using the χ(2) test. Comparison of the accuracy between teeth with and without posts was determined by using the Fisher exact test. The accuracy of the imaging methods showed no significant differences (P = .08). The comparison between teeth with and without posts in each examination revealed significant differences for CBCT with a voxel of 0.125 mm (P = .04) and for periapical radiography (P = .04). No significant differences were observed between CBCT and periapical radiography in the detection of vertical root fractures, except for teeth with metallic posts in images from CBCT with a voxel of 0.125 mm and in digital periapical radiography. Furthermore, voxel size did not significantly influence the diagnosis of vertical root fractures. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Soo; Kim, Gyu Tae [Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Institute of Oral Biology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2008-09-15

    To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-9000TM Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by x2-test. 1. There was no statistical significance according to 3 types (type I, type II, type III) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to

  18. Evaluation of contrast dose reduction for excretory urography using computed radiography

    Energy Technology Data Exchange (ETDEWEB)

    Strautman, P.R.; Fajardo, L.L.; Hillman, B.J.; Yoshino, M.T.; Boyle, R.R. Jr.; Fritz, H.; Mockbee, W.B.

    1989-02-01

    Sixty sequential patients were randomly assigned to undergo computed urography with either our full (282 mg I/kg body weight) or half our usual dose (141 mg I/kg body weight) of intraveneous 60% diatrizoate meglumine. Three blinded observers judged automatically post-processed full dose tomograms and KUBs as qualitatively superior to both automatically post-processed and individually, interactively post-processed half dose images. Thus, post-acquisition image manipulation could not fully compensate for diminished image quality due to contrast dose reduction. (orig./HP).

  19. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Meyer, G.A.; Schwab, J.P.; Flatley, T.J.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.; Knobel, J.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT.

  20. Visibility of Different Intraorbital Foreign Bodies Using Plain Radiography, Computed Tomography, Magnetic Resonance Imaging, and Cone-Beam Computed Tomography: An In Vitro Study.

    Science.gov (United States)

    Javadrashid, Reza; Golamian, Masoud; Shahrzad, Maryam; Hajalioghli, Parisa; Shahmorady, Zahra; Fouladi, Daniel F; Sadrarhami, Shohreh; Akhoundzadeh, Leila

    2017-05-01

    The study sought to compare the usefulness of 4 imaging modalities in visualizing various intraorbital foreign bodies (IOFBs) in different sizes. Six different materials including metal, wood, plastic, stone, glass. and graphite were cut in cylindrical shapes in 4 sizes (dimensions: 0.5, 1, 2, and 3 mm) and placed intraorbitally in the extraocular space of fresh sheep's head. Four skilled radiologists rated the visibility of the objects individually using plain radiography, spiral computed tomography (CT), magnetic resonance imaging (MRI), and cone-beam computed tomography (CBCT) in accordance with a previously described grading system. Excluding wood, all embedded foreign bodies were best visualized in CT and CBCT images with almost equal accuracies. Wood could only be detected using MRI, and then only when fragments were more than 2 mm in size. There were 3 false-positive MRI reports, suggesting air bubbles as wood IOFBs. Because of lower cost and using less radiation in comparison with conventional CT, CBCT can be used as the initial imaging technique in cases with suspected IOFBs. Optimal imaging technique for wood IOFBs is yet to be defined. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Radiographic findings of bisphosphonate-related osteonecrosis of the jaws: Comparison with cone-beam computed tomography and panoramic radiography.

    Science.gov (United States)

    Demir, A; Pekiner, F N

    2017-03-01

    The aim of this study is to assess radiographic findings of bisphosphonate-related osteonecrosis of the jaws (BRONJ) and to evaluate the efficiency of cone-beam computed tomography (CBCT) and panoramic radiography (PR) by comparing with each other. The data of 46 patients treated with bisphosphonates for at least 1 to 10 years were retrospectively examined. 27 patients were selected for study group. The first inclusion criteria was an available CBCT or PR. The patients had at least one clinical symptom of exposed bone, intraoral or extraoral swelling and purulent secretion or fistula formation. In accordance with the position papers of the American Association of Oral and Maxillofacial Surgeons, the patients were classified into stages. CBCT and PR images were evaluated by dividing the jaws in 6 segments. Presence of bone sclerosis, cortex irregularity, persistent sockets, periosteal response, sequestration, and osteolysis were recorded. The radiographic findings of BRONJ were mostly determined at posterior mandible with Stage 2 predominancy. Fifteen patients (55.6%) had previous tooth extraction. 9 of them had exposed bone at the same time. Seven patients had exposed bone without extraction. CBCT findings (P < 0.01) except persistent socket (P = 0.157) were found statistically significant by comparison with PR. Extraction socket finding was detected the same in segments with a percentage of 90.9%. This study showed that CBCT findings except extraction socket were significantly higher than PR. CBCT combined with clinical examination can be used effectively to determine the borders of effected areas especially at advanced cases.

  2. Long-term evaluation of apical root resorption after orthodontic treatment using periapical radiography and cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Jairo Curado de Freitas

    2013-08-01

    Full Text Available OBJECTIVE: To evaluate the frequency of Apical Root Resorption (ARR after orthodontic treatment at 52-288 months using periapical radiography (PR and cone beam computed tomography (CBCT. METHODS: Radiographic images obtained from 58 patients, before (T1 and after orthodontic treatment (T2, and following 52-288 months of treatment were analyzed by three members of the Brazilian Board of Orthodontics. Apical structures were evaluated by PR images (T2 and T3, using Levander and Malmgren scores. The presence of ARR on CBCT images were detected only at T3. The Kolmogorov-Smirnov test was used for statistical analyses, and the level of significance was set at 5%. Kappa statistics determined interobserver agreement. RESULTS: The more frequent ARR were with scores 1 in T2 (51.6% and T3 (53.1%, when evaluated by PR (p > 0.05. When compared the frequencies of ARR in T3 among PR and CBCT images, the differences were significant for maxillary and mandibular pre-molar groups, and for mandibular molar group (p > 0.05. The teeth with highest frequency of ARR presence using CBCT images were maxillary lateral incisors (94.5% and mandibular central incisors (87.7%, while the premolars showed the lowest frequency. The CBCT images showed that the teeth involved in orthodontic treatment with extraction present higher ARR frequency (p < 0.05. CONCLUSION: PR showed more frequency of ARR in posterior teeth groups when compared with CBCT images. ARR did not change in long-term post treatment.

  3. Performance evaluation of a computed radiography imaging device using a typical "front side" and novel "dual side" readout storage phosphors.

    Science.gov (United States)

    Fetterly, Kenneth A; Schueler, Beth A

    2006-02-01

    The Fourier-space modulation transfer function (MTF), normalized noise power spectrum (nNPS), and detective quantum efficiency (DQE) of a computed radiography (CR) x-ray imaging device were measured. Two different storage phosphor screens were used in conjunction with a single CR reader (Fuji, Clearview, CS). One of the storage phosphor plates (ST-BD) had a clear backing material which allowed "dual side read" of the latent image from both the "front" and "back" sides of the phosphor. The other phosphor plate had a light occluding backing material, limiting the readout to front side only (ST-VI). The standard RQA-5 beam quality was used. The MTF was measured using a 1 mm thick tungsten edge device. Compared to the ST-55BD phosphor, the ST-VI phosphor was found to have modestly higher MTF at all spatial frequencies. The nNPS(f) and DQE(f) were measured for nominal incident exposure levels ranging from 0.1 to 10 mR. The dual side read phosphor demonstrated superior DQE, especially at low spatial frequencies. At the frequency 0.5 cycles/mm, the DQE values for the 1 mR exposure were 0.36 and 0.21 for the ST-55BD and ST-VI phosphor plates, respectively. The differences between the spatial-frequency dependent DQE of the two plates can be attributed to the increased signal collection efficiency of the dual side read plates and differences in storage phosphor structure noise.

  4. Radiography, computed tomography and magnetic resonance imaging at 0.5 Tesla of mechanically inducedosteoarthritis in rabbit knees

    Directory of Open Access Journals (Sweden)

    Torelli S.R.

    2004-01-01

    Full Text Available In the present experimental study we assessed induced osteoarthritis data in rabbits, compared three diagnostic methods, i.e., radiography (XR, computed tomography (CT and magnetic resonance imaging (MRI, and correlated the imaging findings with those obtained by macroscopic evaluation. Ten young female rabbits of the Norfolk breed were used. Seven rabbits had the right knee immobilized in extension for a period of 12 weeks (immobilized group, and three others did not have a limb immobilized and were maintained under the same conditions (control group. Alterations observed by XR, CT and MRI after the period of immobilization were osteophytes, osteochondral lesions, increase and decrease of joint space, all of them present both in the immobilized and non-immobilized contralateral limbs. However, a significantly higher score was obtained for the immobilized limbs (XT: P = 0.016, CT: P = 0.031, MRI: P = 0.0156. All imaging methods were able to detect osteoarthritis changes after the 12 weeks of immobilization. Macroscopic evaluation identified increased thickening of joint capsule, proliferative and connective tissue in the femoropatellar joint, and irregularities of articular cartilage, especially in immobilized knees. The differences among XR, CT and MRI were not statistically significant for the immobilized knees. However, MRI using a 0.5 Tesla scanner was statistically different from CT and XR for the non-immobilized contralateral knees. We conclude that the three methods detected osteoarthritis lesions in rabbit knees, but MRI was less sensitive than XR and CT in detecting lesions compatible with initial osteoarthritis. Since none of the techniques revealed all the lesions, it is important to use all methods to establish an accurate diagnosis.

  5. Radiography, computed tomography and magnetic resonance imaging at 0.5 Tesla of mechanically induced osteoarthritis in rabbit knees

    Energy Technology Data Exchange (ETDEWEB)

    Torelli, S.R. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Programa de Pos-graduacao em Medicina Veterinaria; Rahal, R.S. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia e Anestesiologia Veterinaria]. E-mail: sheilacr@fmvz.unesp.br; Volpi, R.S. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina. Dept. de Cirurgia e Ortopedia; Yamashita, S. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina. Dept. de Doencas Tropicais e Diagnostico por Imagens; Mamprim, M.J. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia; Crocci, A.J. [UNESP, Botucatu, SP (Brazil). Inst. de Biociencias. Dept. de Bioestatistica

    2004-04-01

    In the present experimental study we assessed induced osteoarthritis data in rabbits, compared three diagnostic methods, i.e., radiography (XR), computed tomography (CT) and magnetic resonance imaging (MRI), and correlated the imaging findings with those obtained by macroscopic evaluation. Ten young female rabbits of the Norfolk breed were used. Seven rabbits had the right knee immobilized in extension for a period of 12 weeks (immobilized group), and three others did not have a limb immobilized and were maintained under the same conditions (control group). Alterations observed by XR, CT and MRI after the period of immobilization were osteophytes, osteochondral lesions, increase and decrease of joint space, all of them present both in the immobilized and non-immobilized contralateral limbs. However, a significantly higher score was obtained for the immobilized limbs (XT: P = 0.016, CT: P 0.031, MRI: P = 0.0156). All imaging methods were able to detect osteoarthritis changes after the 12 weeks of immobilization. Macroscopic evaluation identified increased thickening of joint capsule, proliferative and connective tissue in the femoropatellar joint, and irregularities of articular cartilage, especially in immobilized knees. The differences among XR, CT and MRI were not statistically significant for the immobilized knees. However, MRI using a 0.5 Tesla scanner was statistically different from CT and XR for the non-immobilized contralateral knees. We conclude that the three methods detected osteoarthritis lesions in rabbit knees, but MRI was less sensitive than XR and CT in detecting lesions compatible with initial osteoarthritis. Since none of the techniques revealed all the lesions, it is important to use all methods to establish an accurate diagnosis. (author)

  6. Application of off-line image processing for optimization in chest computed radiography using a low cost system.

    Science.gov (United States)

    Muhogora, Wilbroad E; Msaki, Peter; Padovani, Renato

    2015-03-08

     The objective of this study was to improve the visibility of anatomical details by applying off-line postimage processing in chest computed radiography (CR). Four spatial domain-based external image processing techniques were developed by using MATLAB software version 7.0.0.19920 (R14) and image processing tools. The developed techniques were implemented to sample images and their visual appearances confirmed by two consultant radiologists to be clinically adequate. The techniques were then applied to 200 chest clinical images and randomized with other 100 images previously processed online. These 300 images were presented to three experienced radiologists for image quality assessment using standard quality criteria. The mean and ranges of the average scores for three radiologists were characterized for each of the developed technique and imaging system. The Mann-Whitney U-test was used to test the difference of details visibility between the images processed using each of the developed techniques and the corresponding images processed using default algorithms. The results show that the visibility of anatomical features improved significantly (0.005 ≤ p ≤ 0.02) with combinations of intensity values adjustment and/or spatial linear filtering techniques for images acquired using 60 ≤ kVp ≤ 70. However, there was no improvement for images acquired using 102 ≤ kVp ≤ 107 (0.127 ≤ p ≤ 0.48). In conclusion, the use of external image processing for optimization can be effective in chest CR, but should be implemented in consultations with the radiologists.

  7. Comparison between cone-beam computed tomography and intraoral digital radiography for assessment of tooth root lesions.

    Science.gov (United States)

    Kumar, Vandana; Gossett, Lauren; Blattner, Ashley; Iwasaki, Laura R; Williams, Karen; Nickel, Jeffrey C

    2011-06-01

    Cone-beam computed tomography (CBCT) might be more accurate in identifying radicular surface lesions compared with digital periapical radiography. In this study, we compared these techniques in detecting simulated root resorption lesions. A porcine mandible was used to support 10 human maxillary central incisors. CBCT and digital periapical radiographic images were generated before and after the introduction of standardized and sequentially larger root defects on either the mesial or the lingual root surfaces. The images were randomly labeled and evaluated by 3 examiners. Each image was classified according to defect size (0, none; 1, mild; 2, moderate; 3, severe). Interrater reliability was acceptable (0.856 ≤ P ≤ 0.981). The location of the root defect (mesial vs lingual) had no significant effect on the evaluation of defect size. Both periapical radiographs and CBCT were slightly better at detecting lingual defects than mesial defects (75% vs 65% and 65% vs 60%, respectively), but these effects were not statistically significant (P = 0.49 and P = 0.74, respectively). The mean percentages of correctly diagnosed defect sizes were 65% for CBCT and 75% for periapical radiographs. Examiners using CBCT images tended to overestimate defect sizes (κ = 0.481) and correctly categorized teeth with no, mild-moderate, and severe defects 80%, 45%, and 90% of the time, respectively. Examiners using periapical radiographs tended to underestimate defect sizes (κ = 0.636) and categorized teeth with no, mild-moderate, and severe defects 100%, 50%, and 100% of the time, respectively. There was no difference in accuracy of identifying defects between periapical radiographs and CBCT images. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. Effect of computer assistance on observer performance of approximal caries diagnosis using intraoral digital radiography.

    Science.gov (United States)

    Araki, Kazuyuki; Matsuda, Yukiko; Seki, Kenji; Okano, Tomohiro

    2010-06-01

    Logicon Caries Detector (LDDC) is the only commercially available computer-assisted diagnostic system for caries diagnosis. The object of this study is to elucidate the efficacy of LDDC when used by inexperienced dentists. Fifty extracted teeth were imaged using an RVG6000. Seven dentists who had just passed the Japanese National Dental Board Examination observed those images without LDDC (woLDDC) and assessed the probability that caries lesions were present, then re-assessed the same teeth using LDDC (wLDDC). The areas under the receiver operating characteristic curves (Az) were compared. No statistically significant difference was found between woLDDC Az values and wLDDC Az values when caries lesions of all depths were considered. When positive cases were restricted to caries lesions in the inner half of the enamel or to dentine caries lesions, however, wLDDC Az values were significantly larger than woLDDC (p = 0.043 and 0.018, respectively).

  9. High-resolution computed tomography in silicosis: correlation with chest radiography and pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto Univ. Hospital. Dept. of Respiratory Function]. E-mail: phel.lop@uol.com.br; Mogami, Roberto; Capone, Domenico; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences; Tessarollo, Bernardo [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Dept. of Radiology and Diagnostic Image; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2008-05-15

    Objective: To correlate tomographic findings with pulmonary function findings, as well as to compare chest X-ray findings with high-resolution computed tomography (HRCT) findings, in patients with silicosis. Methods: A cross-sectional study was conducted in 44 non-smoking patients without a history of tuberculosis. Chest X-ray findings were classified according to the International Labour Organization recommendations. Using a semiquantitative system, the following HRCT findings were measured: the full extent of pulmonary involvement; parenchymal opacities; and emphysema. Spirometry and forced oscillation were performed. Pulmonary volumes were evaluated using the helium dilution method, and diffusing capacity of the lung for carbon monoxide was assessed. Results: Of the 44 patients studied, 41 were male. The mean age was 48.4 years. There were 4 patients who were classified as category 0 based on X-ray findings and as category 1 based on HRCT findings. Using HRCT scans, we identified progressive massive fibrosis in 33 patients, compared with only 23 patients when X-rays were used. Opacity score was found to correlate most closely with airflow, DLCO and compliance. Emphysema score correlated inversely with volume, DLCO and airflow. In this sample of patients presenting a predominance of large opacities (75% of the individuals), the deterioration of pulmonary function was associated with the extent of structural changes. Conclusions: In the early detection of silicosis and the identification of progressive massive fibrosis, HRCT scans are superior to X-rays. (author)

  10. A comparative study on the diagnostic utility of ultrasonography with conventional radiography and computed tomography scan in detection of zygomatic arch and mandibular fractures

    Directory of Open Access Journals (Sweden)

    Koijam Sashikumar Singh

    2014-01-01

    Full Text Available Objectives: The objective of the following study is to evaluate the usefulness of ultrasonography (USG in comparison with conventional radiography and computed tomography (CT scan in the diagnosis of zygomatic arch and mandibular fractures. Materials and Methods: A total of 40 patients with suspected fracture of the zygomatic arch and/or mandibular fractures were included in the study. Two groups (one for zygomatic arch fractures and the other for mandibular fractures of 20 patients each were designed for the study. Ultrasonographic examinations were performed using small linear probe (LA435, Siemens Acuson Antares with 10 MHz frequency. Data from CT and conventional radiography were compared with that of USG. Results: Sensitivity and specificity of USG in assessing zygomatic arch fractures were 100% and 100%, respectively; and that of mandibular fractures were 94.74% and 100%, respectively. Overall sensitivity, specificity, positive predictive value, and negative predictive value of USG against CT in diagnosing zygomatic arch and mandibular fractures were found out to be 97.4%, 100%, 100%, and 66.7%, respectively. Conclusion: USG is a very reliable tool in detection of fractures involving zygomatic arch and mandible. It can be used for screening of suspected fractures of zygomatic arch and mandible to avoid unnecessary radiation exposure from conventional radiography and CT scans.

  11. A comparative study on the diagnostic utility of ultrasonography with conventional radiography and computed tomography scan in detection of zygomatic arch and mandibular fractures.

    Science.gov (United States)

    Singh, Koijam Sashikumar; Jayachandran, S

    2014-04-01

    The objective of the following study is to evaluate the usefulness of ultrasonography (USG) in comparison with conventional radiography and computed tomography (CT) scan in the diagnosis of zygomatic arch and mandibular fractures. A total of 40 patients with suspected fracture of the zygomatic arch and/or mandibular fractures were included in the study. Two groups (one for zygomatic arch fractures and the other for mandibular fractures) of 20 patients each were designed for the study. Ultrasonographic examinations were performed using small linear probe (LA435, Siemens Acuson Antares) with 10 MHz frequency. Data from CT and conventional radiography were compared with that of USG. Sensitivity and specificity of USG in assessing zygomatic arch fractures were 100% and 100%, respectively; and that of mandibular fractures were 94.74% and 100%, respectively. Overall sensitivity, specificity, positive predictive value, and negative predictive value of USG against CT in diagnosing zygomatic arch and mandibular fractures were found out to be 97.4%, 100%, 100%, and 66.7%, respectively. USG is a very reliable tool in detection of fractures involving zygomatic arch and mandible. It can be used for screening of suspected fractures of zygomatic arch and mandible to avoid unnecessary radiation exposure from conventional radiography and CT scans.

  12. Diagnostic Accuracy of Cone-beam Computed Tomography and Conventional Radiography on Apical Periodontitis: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Leonardi Dutra, Kamile; Haas, Letícia; Porporatti, André Luís; Flores-Mir, Carlos; Nascimento Santos, Juliana; Mezzomo, Luis André; Corrêa, Márcio; De Luca Canto, Graziela

    2016-03-01

    Endodontic diagnosis depends on accurate radiographic examination. Assessment of the location and extent of apical periodontitis (AP) can influence treatment planning and subsequent treatment outcomes. Therefore, this systematic review and meta-analysis assessed the diagnostic accuracy of conventional radiography and cone-beam computed tomographic (CBCT) imaging on the discrimination of AP from no lesion. Eight electronic databases with no language or time limitations were searched. Articles in which the primary objective was to evaluate the accuracy (sensitivity and specificity) of any type of radiographic technique to assess AP in humans were selected. The gold standard was the histologic examination for actual AP (in vivo) or in situ visualization of bone defects for induced artificial AP (in vitro). Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v.5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark) and MetaDisc v.1.4. software (Unit of Clinical Biostatistics Team of the Ramón y Cajal Hospital, Madrid, Spain). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. Only 9 studies met the inclusion criteria and were subjected to a qualitative analysis. A meta-analysis was conducted on 6 of these articles. All of these articles studied artificial AP with induced bone defects. The accuracy values (area under the curve) were 0.96 for CBCT imaging, 0.73 for conventional periapical radiography, and 0.72 for digital periapical radiography. No evidence was found for panoramic radiography. Periapical radiographs (digital and conventional) reported good diagnostic accuracy on the discrimination of artificial AP from no lesions, whereas CBCT imaging showed excellent accuracy values. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Imaging in rheumatoid arthritis--status and recent advances for magnetic resonance imaging, ultrasonography, computed tomography and conventional radiography

    DEFF Research Database (Denmark)

    Østergaard, Morten; Pedersen, Susanne Juhl; Dohn, U.M.

    2008-01-01

    Sensitive and reproducible tools for diagnosis, monitoring of disease activity and damage, and prognostication are essential in the management of patients with rheumatoid arthritis (RA). Conventional radiography (X-ray), the traditional gold standard for imaging in RA, is not able to detect early...

  14. Investigation of a multi-biomarker disease activity score in rheumatoid arthritis by comparison with magnetic resonance imaging, computed tomography, ultrasonography, and radiography parameters of inflammation and damage

    DEFF Research Database (Denmark)

    Krabbe, S.; Bolce, R.; Brahe Pedersen, C.

    2017-01-01

    Objectives: To investigate the multi-biomarker disease activity (MBDA) score by comparison with imaging findings in an investigator-initiated rheumatoid arthritis (RA) trial (HURRAH trial, NCT00696059). Method: Fifty-two patients with established RA initiated adalimumab treatment and had magnetic...... resonance imaging (MRI), ultrasonography (US), computed tomography (CT), and radiography performed at weeks 0, 26, and 52. Serum samples were analysed using MBDA score assays and associations between clinical measures, MBDA score, and imaging findings were investigated. Results: The MBDA score correlated...... significantly with MRI synovitis (rho = 0.65, p CRP)

  15. Single source dual-energy computed tomography in the diagnosis of gout: Diagnostic reliability in comparison to digital radiography and conventional computed tomography of the feet

    Energy Technology Data Exchange (ETDEWEB)

    Kiefer, Tobias; Diekhoff, Torsten [Department of Radiology, Charité—Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität, Berlin, Charitéplatz 1, 10117 Berlin (Germany); Hermann, Sandra [Department of Rheumatology and Clinical Immunology, Charité—Universitätsmedizin Berlin Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität Berlin, Charitéplatz 1, 10117 Berlin (Germany); Stroux, Andrea [Department of Medical Informatics, Biometry and Epidemiology, Freie Universität Berlin, Berlin (Germany); Mews, Jürgen; Blobel, Jörg [Toshiba Medical Systems Europe, BV, Zilverstraat 1, 2701 RP Zoetermeer (Netherlands); Hamm, Bernd [Department of Radiology, Charité—Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität, Berlin, Charitéplatz 1, 10117 Berlin (Germany); Hermann, Kay-Geert A., E-mail: kghermann@gmail.com [Department of Radiology, Charité—Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität, Berlin, Charitéplatz 1, 10117 Berlin (Germany)

    2016-10-15

    Objectives: To investigate the diagnostic value of single-source dual-energy computed tomography (SDECT) in gouty arthritis and to compare its capability to detect urate depositions with digital radiography (DR) and conventional computed tomography (CT). Methods: Forty-four patients who underwent SDECT volume scans of the feet for suspected gouty arthritis were retrospectively analyzed. SDECT, CT (both n = 44) and DR (n = 36) were scored by three blinded readers for presence of osteoarthritis, erosions, and tophi. A diagnosis was made for each imaging modality. Results were compared to the clinical diagnosis using the American College of Rheumatology (ACR) classification criteria. Results: The patient population was divided into a gout (n = 21) and control (n = 23) group based on final clinical diagnosis. Osteoarthritis was evident in 15 joints using CT and 30 joints using DR (p = 0.165). There were 134 erosions detected by CT compared to 38 erosions detected by DR (p < 0.001). In total 119 tophi were detected by SDECT, compared to 85 tophi by CT (p = 0.182) and 25 tophi by DR (p < 0.001). SDECT had best diagnostic value for diagnosis of gout compared to DR and conventional CT (sensitivity and specificity for SDECT: 71.4% and 95.7%, CT: 71.4% and 91.3% and DR: 44.4% and 83.3%, respectively). For all three readers, Cohen’s kappa for DR and conventional CT were substantial for all scoring items and ranged from 0.75 to 0.77 and 0.72–0.76, respectively. For SDECT Cohen’s kappa was good to almost perfect with 0.77–0.84. Conclusions: SDECT is capable to detect uric acid depositions with good sensitivity and high specificity in feet, therefore diagnostic confidence is improved. Using SDECT, inter-reader variance can be markedly reduced for the detection of gouty tophi.

  16. Efficacy of plain radiography and computer tomography in localizing the site of pelvic arterial bleeding in trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Dormagen, Johann B. (Dept. of Radiology, Oslo Univ. Hospital, Ullevaal, Oslo (Norway)), e-mail: johannd@medisin.uio.no; Toetterman, Anna (Dept. of Orthopedic Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)); Roeise, Olav (Div. of Neuroscience and Musculoskeletal Medicine, Oslo Univ. Hospital, Ullevaal, Oslo (Norway)); Sandvik, Leiv (Center for Clinical Research, Oslo Univ. Hospital, Ullevaal, Oslo (Norway)); Kloew, Nils-E. (Dept. of Cardiovascular Radiology, Oslo Univ. Hospital - Ullevaal, Oslo (Norway))

    2010-01-15

    Background: Immediate angiography is warranted in pelvic trauma patients with suspected arterial injury (AI) in order to stop ongoing bleeding. Prior to angiography, plain pelvic radiography (PPR) and abdominopelvic computer tomography (CT) are performed to identify fracture and hematoma sites. Purpose: To investigate if PPR and CT can identify the location of AI in trauma patients undergoing angiography. Material and Methods: 95 patients with pelvic fractures on PPR (29 women, 66 men), at a mean age of 44 (9-92) years, underwent pelvic angiography for suspected AI. Fifty-six of them underwent CT additionally. Right and left anterior and posterior fractures on PPR were registered, and fracture displacement was recorded for each quadrant. Arterial blush on CT was registered, and the size of the hematoma in each region was measured in cm2. AIs were registered for anterior and posterior segments of both internal iliac arteries. Presence of fractures, arterial blush, and hematomas were correlated with AI. Results: Presence of fracture in the corresponding skeletal segment on PPR showed sensitivity and specificity of 0.86 and 0.58 posteriorly, and 0.87 and 0.44 anteriorly. The area under the curve (AUC) was 0.77 and 0.69, respectively. Fracture displacement on PPR >0.9 cm posteriorly and >1.9 cm anteriorly revealed specificity of 0.84. Sensitivities of arterial blush and hematoma on CT were 0.38 and 0.82 posteriorly, and 0.24 and 0.82 anteriorly. The specificities were 0.96 and 0.58 posteriorly, and 0.79 and 0.53 anteriorly, respectively. For hematomas, the AUC was 0.79 posteriorly and 0.75 anteriorly. Size of hematoma >22 cm2 posteriorly and >29 cm2 anteriorly revealed specificity of 0.85 and 0.86, respectively. Conclusion: CT findings of arterial blush and hematoma predicted site of arterial bleeding on pelvic angiography. Also, PPR predicted the site of bleeding using location of fracture and size of displacement. In the hemodynamically unstable patient, PPR may

  17. On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Day, R. A.; Sankar, A. P.; Nailon, W. H.; MacLeod, A. S. [Department of Oncology Physics, Edinburgh Cancer Centre, Western General Hospital, Crewe Road South, Edinburgh EH4 2XU (United Kingdom)

    2011-02-15

    Purpose: As traditional film is phased out in most radiotherapy centers, computed radiography (CR) systems are increasingly being purchased as a replacement. CR plates can be used for patient imaging, but may also be used for a variety of quality assurance (QA) purposes and can be calibrated in terms of dose. This study looks at their suitability for verification of intensity modulated radiation therapy (IMRT) dose distributions. Methods: A CR plate was calibrated in terms of the relative dose and the stability of response over 1 year was studied. The effect of exposing the CR plate to ambient light and of using different time delays before scanning was quantified. The CR plate was used to verify the relative dose distributions for ten IMRT patients and the results were compared to those obtained using a two dimensional (2D) diode array. Results: Exposing the CR plate to 10 s of ambient light between irradiation (174 cGy) and scanning erased approximately 80% of the signal. Changes in delay time between irradiation and scanning also affected the measurement results. The signal on the plate was found to decay at a rate of approximately 3.6 cGy/min in the first 10 min after irradiation. The use of a CR plate for IMRT patient-specific QA resulted in a significantly lower distance to agreement (DTA) and gamma pass rate than when using a 2D diode array for the measurement. This was primarily due to the over-response of the CR phosphor to low energy scattered radiation. For the IMRT QA using the CR plate, the average gamma pass rate was 97.3%. For the same IMRT QA using a diode array, the average gamma pass rate was 99.7%. The gamma criteria used were 4% dose difference and 4 mm DTA for head and neck treatments and 3% dose difference and 3 mm DTA for prostate treatments. The gamma index tolerance was 1. The lowest 10% of the dose distribution was excluded from all gamma and DTA analyses. Conclusions: Although the authors showed that CR plates can be used for patient

  18. Analisis gambaran histogramdan densitas kamar pulpa pada gigi suspek pulpitis reversibel dan ireversibel dengan menggunakan radiografi cone beam computed tomography (Histogram and density analysis of irreversible and reversible pulpitissuspected tooth using cone beam computed tomography radiography)

    OpenAIRE

    Lusi Epsilawati; Suhardjo Sitam; Sam Belly; Fahmi Oscandar

    2014-01-01

    Inflammation of the pulp is most common and difficult to diagnose. For it radiographs is necessary. One attempt to do is to assess its histogram and density. Radiography equipment that has the ability to analyze is cone beam computed tomography (CBCT). The purpose of this study is to analyze radiograph of the pulp chamber histogram: peak value, grayscale and trends , as well as the density on the condition reversible and irreversible pulpitis condition. The population of this ...

  19. Indications for computed tomography (CT- diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography

    Directory of Open Access Journals (Sweden)

    Weise Kuno

    2009-04-01

    Full Text Available Abstract Background Precise indications for computed tomography (CT in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X-rays (22 AP + axillary views, 22 AP + scapular Y-views and CT (multi-planar reconstruction (MPR and maximum intensity projection (MIP with 2 D and 3 D imaging. 3 observers assessed the technical image quality, the assessment of the relevant anatomical structures (2-sample-t-test and the percentage of the osseous overlap of the proximal humerus (Welch-test using a scoring system. The quality of the different diagnostic methods was assessed according to the number of fractured parts (Bonferroni-Holm adjustment. Results There was significantly more overlap of the fractured region on the scapular Y-views (mean 71.5%, range 45–90% than on axillary views (mean 56.2%, range 10.5–100%. CT-diagnostics allowed a significantly better assessment of the relevant structures than conventional diagnostics (p Conclusion Conventional X-rays with AP view and a high-quality axillary view are useful for primary diagnostics of the fracture and often but not always show a clear presentation of the relevant bony structures such as both tuberosities, the glenoid and humeral head. CT with thin slices technology and additional 3 D imaging provides always a clear presentation of the fractured region. Clinically, a CT should be performed – independently of the number of fractured parts – when the proximal humerus and the shoulder joint are not presented with sufficient X-ray-quality to establish a treatment plan.

  20. Morphology of the pelvis and hind limb of the red panda (Ailurus fulgens) evidenced by gross osteology, radiography and computed tomography.

    Science.gov (United States)

    Makungu, M; du Plessis, W M; Groenewald, H B; Barrows, M; Koeppel, K N

    2015-12-01

    The red panda (Ailurus fulgens) is a quadrupedal arboreal animal primarily distributed in the Himalayas and southern China. It is a species commonly kept in zoological collections. This study was carried out to describe the morphology of the pelvis and hind limb of the red panda evidenced by gross osteology, radiography and computed tomography as a reference for clinical use and identification of skeletons. Radiography of the pelvis and right hind limb was performed in nine and seven animals, respectively. Radiographic findings were correlated with bone specimens from three adult animals. Computed tomography of the torso and hind limb was performed in one animal. The pelvic bone had a wide ventromedial surface of the ilium. The trochlea of the femur was wide and shallow. The patella was similar to that seen in feline species. The medial fabella was not seen radiographically in any animal. The cochlea grooves of the tibia were shallow with a poorly defined intermediate ridge. The trochlea of the talus was shallow and presented with an almost flattened medial ridge. The tarsal sesamoid bone was always present. The lateral process of the base of the fifth metatarsal (MT) bone was directed laterally. The MT bones were widely spaced. The morphology of the pelvis and hind limb of the red panda indicated flexibility of the pelvis and hind limb joints as an adaptation to an arboreal quadrupedal lifestyle. © 2014 Blackwell Verlag GmbH.

  1. Direitos humanos e OEA. Processos e procedimentos

    Directory of Open Access Journals (Sweden)

    Christian Perrone

    2015-08-01

    Full Text Available Este artigo busca preencher a lacuna no tratamento do Direito Internacional dos Direitos Humanos, focando nos procedimentos internos dos organismos internacionais que acabam por dar corpo (positiva ou negativamente para estes conceitos jurídicos. Os três principais eixos serão os órgãos da Organização dos Estados Americanos que tratam destes direitos, os procedimentos gerais, e os mecanismos individuais de proteção. Como conclusão, tem-se que toda a Organização é responsável pela realização, desenvolvimento e proteção de direitos e que a sociedade coletiva ou individualmente possui espaço de influência através de mecanismos próprios.

  2. Rhinoceros Feet Step Out of a Rule-of-Thumb: A Wildlife Imaging Pioneering Approach of Synchronized Computed Tomography-Digital Radiography

    Science.gov (United States)

    Saragusty, Joseph; Göritz, Frank; Potier, Romain; Mulot, Baptiste; Maillot, Alexis; Etienne, Pascal; Bernardino, Rui; Fernandes, Teresa; Mews, Jurgen; Hildebrandt, Thomas Bernd

    2014-01-01

    Currently, radiography is the only imaging technique used to diagnose bone pathology in wild animals situated under “field conditions”. Nevertheless, while chronic foot disease in captive mega-herbivores is widely reported, foot radiographic imaging is confronted with scarcity of studies. Numerous hindrances lead to such limited numbers and it became very clear that the traditional perspective on bone imaging in domestic animals based on extensive studies and elaborated statistical evaluations cannot be extrapolated to their non-domestic relatives. For these reasons, the authors initiated a multi-modality imaging study and established a pioneering approach of synchronized computed tomography (CT) and digital radiography (DR), based on X-ray projections derived from three-dimensional CT reconstructed images. Whereas this approach can be applied in any clinical field, as a case of outstanding importance and great concern for zoological institutions, we selected foot bone pathologies in captive rhinoceroses to demonstrate the manifold applications of the method. Several advances were achieved, endowing the wildlife clinician with all-important tools: prototype DR exposure protocols and a modus operandi for foot positioning, advancing both traditional projections and, for the first-time, species-related radiographic views; assessment of radiographic diagnostic value for the whole foot and, in premiere, for each autopodial bone; together with additional insights into radiographic appearance of bone anatomy and pathology with a unique, simultaneous CT-DR correlation. Based on its main advantages in availing a wide range of keystone data in wildlife imaging from a limited number of examined subjects and combining advantages of CT as the golden standard method for bone diseases' diagnostic with DR's clinical feasibility under field conditions, synchronized CT-DR presents a new perspective on wildlife's health management. With this we hope to provide veterinary

  3. Computed tomography scout views vs. conventional radiography in body-packers – Delineation of body-packs and radiation dose in a porcine model

    Energy Technology Data Exchange (ETDEWEB)

    Ziegeler, Edvard, E-mail: edvard.ziegeler@campus.lmu.de [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstraße 20, 80336 Munich (Germany); Grimm, Jochen M., E-mail: jochen.grimm@med.lmu.de [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstraße 20, 80336 Munich (Germany); Wirth, Stefan, E-mail: tefan.wirth@med.lmu.de [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstraße 20, 80336 Munich (Germany); Uhl, Michael, E-mail: michael.uhl@polizei.bayern.de [Bavarian State Criminal Police Office, Maillingerstrasse 15, 80636 Munich (Germany); Reiser, Maximilian F., E-mail: Maximilian.Reiser@med.lmu.de [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstraße 20, 80336 Munich (Germany); Scherr, Michael K., E-mail: Michael.Scherr@med.lmu.de [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstraße 20, 80336 Munich (Germany)

    2012-12-15

    Objective: To compare abdominal computed tomography (CT) scout views with conventional radiography regarding radiation dose and delineation of drug packages in a porcine body-packer model. Materials and methods: Nine samples of illicit drugs packed in ovoid plastic containers were consecutively placed in the rectum of a 121.5 kg pig cadaver. Antero-posterior and lateral scout views were obtained at 120 kVp and 80 mA, 150 mA and 200 mA, respectively, using a 64-row MDCT. Scout views were compared with conventional abdominal antero-posterior radiographs (77 kV and 106 ± 13 mAs). Visibility of three body pack characteristics (wrapping, content, shape) was rated independently by two radiologists and summarized to a delineation score ranging from 0 to 9 with a score ≥6 representing sufficient delineation. Mean delineation scores were calculated for each conventional radiography and single plane scout view separately and for a combined rating of antero-posterior and lateral scout views. Results: Even the lowest single plane scout view delineation score (5.3 ± 2.0 for 80 mA lateral; 0.4 mSv; sensitivity = 44%) was significantly higher than for conventional radiographs (3.1 ± 2.5, p < 0.001; 2.4 ± 0.3 mSv; sensitivity = 11%). Combined reading of antero-posterior and lateral scout views 80 mA yielded sufficient delineation (6.2 ± 1.4; 0.8 mSv; sensitivity = 56%). Conclusions: All CT scout views showed significantly better delineation ratings and sensitivity than conventional radiographs. Scout views in two planes at 80 mA provided a sufficient level of delineation and a sensitivity five times higher than conventional radiography at less than one third of the radiation dose. In case of diagnostic insecurity, CT can be performed without additional logistical effort.

  4. Rhinoceros feet step out of a rule-of-thumb: a wildlife imaging pioneering approach of synchronized computed tomography-digital radiography.

    Directory of Open Access Journals (Sweden)

    Gabriela Galateanu

    Full Text Available Currently, radiography is the only imaging technique used to diagnose bone pathology in wild animals situated under "field conditions". Nevertheless, while chronic foot disease in captive mega-herbivores is widely reported, foot radiographic imaging is confronted with scarcity of studies. Numerous hindrances lead to such limited numbers and it became very clear that the traditional perspective on bone imaging in domestic animals based on extensive studies and elaborated statistical evaluations cannot be extrapolated to their non-domestic relatives. For these reasons, the authors initiated a multi-modality imaging study and established a pioneering approach of synchronized computed tomography (CT and digital radiography (DR, based on X-ray projections derived from three-dimensional CT reconstructed images. Whereas this approach can be applied in any clinical field, as a case of outstanding importance and great concern for zoological institutions, we selected foot bone pathologies in captive rhinoceroses to demonstrate the manifold applications of the method. Several advances were achieved, endowing the wildlife clinician with all-important tools: prototype DR exposure protocols and a modus operandi for foot positioning, advancing both traditional projections and, for the first-time, species-related radiographic views; assessment of radiographic diagnostic value for the whole foot and, in premiere, for each autopodial bone; together with additional insights into radiographic appearance of bone anatomy and pathology with a unique, simultaneous CT-DR correlation. Based on its main advantages in availing a wide range of keystone data in wildlife imaging from a limited number of examined subjects and combining advantages of CT as the golden standard method for bone diseases' diagnostic with DR's clinical feasibility under field conditions, synchronized CT-DR presents a new perspective on wildlife's health management. With this we hope to provide

  5. Diagnostic performance of the visual caries classification system ICDAS II versus radiography and micro-computed tomography for proximal caries detection: an in vitro study.

    Science.gov (United States)

    Mitropoulos, P; Rahiotis, C; Stamatakis, H; Kakaboura, A

    2010-11-01

    The purpose of this study was: (a) to compare the visual caries classification system ICDAS II with conventional (CR) and digital radiography (DR) for diagnosis of non-cavitated caries on free proximal surfaces, (b) to examine the potential of micro-computed tomography (MCT) to substitute histological examination for the in vitro caries assessment. Both proximal surfaces of 20 teeth received classification separately by two examiners by means of the diagnostic modalities examined. The teeth were sectioned and assessed for depth of the lesion. The modalities were compared in terms of degree of inter-examiner agreement, sensitivity, specificity, accuracy, positive and negative predictive value and validity. Two diagnostic thresholds were applied: no caries versus all caries scores (D1), and no dentin caries versus dentin caries (D3). The weighted kappa values for inter-examiner reproducibility for all diagnostic modalities were 0.51-0.81. Visual examination (ICDAS II) reached significant higher sensitivity (0.92-0.96) and negative predictive value (0.9-1) than radiography. Likewise, the radiographic modalities presented significantly higher specificity (0.93-1) and positive predictive values (0.92-1) than the ICDAS II criteria. The overall accuracy performance of radiographic modalities was related to the diagnostic threshold. MCT did not agree with histological validation at each disease severity scale. The ICDAS II criteria are a promising tool for caries diagnosis on free proximal surfaces. DR and CR radiography present comparable performance. Furthermore, MCT is not capable of constituting a reliable alternative to histological examination for caries research. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Digital Radiography

    Science.gov (United States)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  7. Prevalence and Clinical Import of Thoracic Injury Identified by Chest Computed Tomography but Not Chest Radiography in Blunt Trauma: Multicenter Prospective Cohort Study.

    Science.gov (United States)

    Langdorf, Mark I; Medak, Anthony J; Hendey, Gregory W; Nishijima, Daniel K; Mower, William R; Raja, Ali S; Baumann, Brigitte M; Anglin, Deirdre R; Anderson, Craig L; Lotfipour, Shahram; Reed, Karin E; Zuabi, Nadia; Khan, Nooreen A; Bithell, Chelsey A; Rowther, Armaan A; Villar, Julian; Rodriguez, Robert M

    2015-12-01

    Chest computed tomography (CT) diagnoses more injuries than chest radiography, so-called occult injuries. Wide availability of chest CT has driven substantial increase in emergency department use, although the incidence and clinical significance of chest CT findings have not been fully described. We determine the frequency, severity, and clinical import of occult injury, as determined by changes in management. These data will better inform clinical decisions, need for chest CT, and odds of intervention. Our sample included prospective data (2009 to 2013) on 5,912 patients at 10 Level I trauma center EDs with both chest radiography and chest CT at physician discretion. These patients were 40.6% of 14,553 enrolled in the parent study who had either chest radiography or chest CT. Occult injuries were pneumothorax, hemothorax, sternal or greater than 2 rib fractures, pulmonary contusion, thoracic spine or scapula fracture, and diaphragm or great vessel injury found on chest CT but not on preceding chest radiography. A priori, we categorized thoracic injuries as major (having invasive procedures), minor (observation or inpatient pain control >24 hours), or of no clinical significance. Primary outcome was prevalence and proportion of occult injury with major interventions of chest tube, mechanical ventilation, or surgery. Secondary outcome was minor interventions of admission rate or observation hours because of occult injury. Two thousand forty-eight patients (34.6%) had chest injury on chest radiography or chest CT, whereas 1,454 of these patients (71.0%, 24.6% of all patients) had occult injury. Of these, in 954 patients (46.6% of injured, 16.1% of total), chest CT found injuries not observed on immediately preceding chest radiography. In 500 more patients (24.4% of injured patients, 8.5% of all patients), chest radiography found some injury, but chest CT found occult injury. Chest radiography found all injuries in only 29.0% of injured patients. Two hundred and two

  8. Cholesteatoma: computed tomography and radiography in a dog; Colesteatoma: tomografia computadorizada e radiografia em cao com otite cronica

    Energy Technology Data Exchange (ETDEWEB)

    Belotta, Alexandra Frey; Babicsak, Viviam Rocco; Mamprim, Maria Jaqueline; Vulcano, Luiz Carlos, E-mail: a_fbelotta@yahoo.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia . Dept. de Reproducao Animal e Radiologia Veterinaria; Arruda, Vanesa Kutz de; Amorim, Rogerio Martins [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Clinica Veterinaria

    2012-07-01

    Cholesteatoma, a rare and/or misdiagnosed disease, results of a serious complication in dogs with chronic otitis. This article describes a case of a dachshund sent to the veterinary hospital presenting signs of cognitive dysfunction associated to peripheral neuropathy of the facial nerve on the right side. At radiography, an enlargement and thickness of the contours associated with loss of anatomical definition of the right tympanic bulla compared to the left was seen. At tomography, this enlargement and thickness were seen with better definition, besides the fulfilling by hyperdense calcified content, bullae osteolysis and temporal bone sclerosis at the same side. (author)

  9. A-Si:H/CsI(Tl) flat-panel versus computed radiography for chest imaging applications: image quality metrics measurement.

    Science.gov (United States)

    Liu, Xinming; Shaw, Chris C

    2004-01-01

    Amorphous silicon (a-Si:H) flat-panel (FP) imaging systems have recently become commercially available for both chest and mammographic imaging applications. It has been shown that this new detector technology offers better image quality and various operational advantages over the computed radiography (CR) which to date has been the most widely implemented and used digital radiography technique. However, most image quality measurements reported on flat-panel systems have been performed on prototype systems in laboratories while those for CR systems were typically independently performed and reported on in separate studies. To directly compare the two technologies, we have measured the image properties for a commercial amorphous silicon/cesium iodide [a-Si:H/CsI(Tl)] flat-panel based digital chest system and a commercial CR system under clinical imaging conditions. In this paper, measurements of image quality metrics, including the modulation transfer functions (MTFs), noise power spectra (NPSs), and detective quantum efficiencies (DQEs), for the FP and CR systems are presented and compared. Methods and issues related to these measurements are discussed. The results show that the flat-panel system has slightly lower MTF but significantly higher DQEs than the CR system. The DQEs of the flat-panel system were found to increase with the exposure while those of the CR system decrease slightly with the exposure.

  10. Comparison of cone beam computed tomography and digital intraoral radiography performance in the detection of artificially induced recurrent caries-like lesions.

    Science.gov (United States)

    Sousa Melo, Saulo Leonardo; Belem, Manuella Dias Furtado; Prieto, Lucia Trazzi; Tabchoury, Cinthia Pereira Machado; Haiter-Neto, Francisco

    2017-09-01

    The aim of this study was to compare the performance of cone beam computed tomography (CBCT) and digital radiography in the detection of artificial recurrent caries-like lesions under amalgam and composite fillings. The study included class II cavities in 30 molars that had been filled with amalgam. Fifteen of those molars had the restoration-enamel interface artificially demineralized. Phantoms were prepared, and CBCT images were acquired with 2 units in 3 voxel sizes (K9000, 0.076 mm; i-CAT, 0.2 mm and 0.4 mm). Intraoral radiographs were obtained with 3 systems (Digora, VistaScan, and RVG-6100). Amalgam fillings were then replaced by composite, and new images were obtained. Three examiners assessed all of the images. Sensitivity, specificity, accuracy, and receiver operating characteristic curve were calculated and verified through analysis of variance and the Tukey test. There were no significant differences in sensitivity and specificity when the same restorative material was present or when the restorative materials were compared with the imaging technique as a constant. As for accuracy and receiver operating characteristic curve, there were statistically significant differences when the 2 materials were compared, and there were differences in the amalgam group when the imaging modalities were compared. CBCT performed similarly to intraoral radiography in detecting demineralization under restorations. However, the voxel size and the type of restorative material influenced its performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Influence of radioactive sources discretization in the Monte Carlo computational simulations of brachytherapy procedures: a case study on the procedures for treatment of prostate cancer; Influencia da discretizacao das fontes radioativas nas simulacoes computacionais Monte Carlo de procedimentos de braquiterapia: um estudo de caso sobre os procedimentos para tratamento do cancer de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Antonio Konrado de Santana; Vieira, Jose Wilson [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Costa, Kleber Souza Silva [Faculdade Integrada de Pernambuco (FACIPE), Recife, PE (Brazil); Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-07-01

    Radiotherapy computational simulation procedures using Monte Carlo (MC) methods have shown to be increasingly important to the improvement of cancer fighting strategies. One of the biases in this practice is the discretization of the radioactive source in brachytherapy simulations, which often do not match with a real situation. This study had the aim to identify and to measure the influence of radioactive sources discretization in brachytherapy MC simulations when compared to those that do not present discretization, using prostate brachytherapy with Iodine-125 radionuclide as model. Simulations were carried out with 108 events with both types of sources to compare them using EGSnrc code associated to MASH phantom in orthostatic and supine positions with some anatomic adaptations. Significant alterations were found, especially regarding bladder, rectum and the prostate itself. It can be concluded that there is a need to discretized sources in brachytherapy simulations to ensure its representativeness. (author)

  12. Filmless Radiography

    Science.gov (United States)

    1997-01-01

    Technology initially prototyped under a Small Business Innovation Research contract between Quantex Corporation and Langley Research Center was licensed to Liberty Technology and incorporated into RADView, a new filmless radiography technology. The NASA-sponsored work involved the investigation of Electron Trapping, which led to a solid-state film that uses a special class of photoluminescent materials to capture radiographic images. RadView is a total imaging solution for the conversion of radiographic film records to digital format and digital acquisitions of radiographs. With the RADView technology, there is a reduction of exposure times and errors; film waste is eliminated; and the efficiency of data management and precise image analysis is boosted. The solid-state film can be exposed, read, erased, and re- exposed indefinitely until mechanical replacement is required. Digital images can be stored to optical media for up to 100 years and beyond without information loss.

  13. Electron radiography

    Science.gov (United States)

    Merrill, Frank E.; Morris, Christopher

    2005-05-17

    A system capable of performing radiography using a beam of electrons. Diffuser means receive a beam of electrons and diffuse the electrons before they enter first matching quadrupoles where the diffused electrons are focused prior to the diffused electrons entering an object. First imaging quadrupoles receive the focused diffused electrons after the focused diffused electrons have been scattered by the object for focusing the scattered electrons. Collimator means receive the scattered electrons and remove scattered electrons that have scattered to large angles. Second imaging quadrupoles receive the collimated scattered electrons and refocus the collimated scattered electrons and map the focused collimated scattered electrons to transverse locations on an image plane representative of the electrons' positions in the object.

  14. [Digital radiography].

    Science.gov (United States)

    Haendle, J

    1983-03-01

    Digital radiography is a generally accepted term comprising all x-ray image systems producing a projected image which resembles the conventional x-ray film image, and which are linked to any type of digital image processing. Fundamental criteria of differentiation are based on the production and detection method of the x-ray image. Various systems are employed, viz. the single-detector, line-detector or fanbeam detector and the area-beam or area-detector image converters, which differ from one another mainly in the manner of conversion of the radiation produced by the x-ray tube. The article also deals with the pros and cons of the various principles, the multitude of systems employed, and the varying frequency of their use in x-ray diagnosis work.

  15. IMAGING DIAGNOSIS - RADIOGRAPHY, ULTRASONOGRAPHY, AND COMPUTED TOMOGRAPHY OF A GIANT FECALOMA CAUSING STERCORAL PERFORATION OF THE COLON IN A DOG WITH A PROSTATIC ABSCESS.

    Science.gov (United States)

    Kim, Jaehwan; Yoon, Hakyoung; Eom, Kidong

    2017-02-04

    A mixed-breed dog presented with tenesmus, hematochezia, and abdominal distension of 2 weeks duration. Radiography showed a large round mass with a "soap-bubble" appearance and shell-like mineralization in the caudal abdomen. Computed tomography revealed a lamellate mineralized mass 8 cm in diameter and containing air in the descending colon and prostatic abscess. Heterogeneously contrast-enhanced, irregularly thickened colonic wall with intramural and peritoneal free gas indicated stercoral colonic perforation. Surgical intervention revealed a tumor-like giant fecaloma in the descending colon adjoining the prostate with extensive wall rupture and fecal peritonitis. Hypothetically, prostatic inflammation may affect colonic motility with resultant fecaloma formation. © 2017 American College of Veterinary Radiology.

  16. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  17. A method to incorporate the effect of beam quality on image noise in a digitally reconstructed radiograph (DRR) based computer simulation for optimisation of digital radiography.

    Science.gov (United States)

    Moore, Craig S; Wood, Tim J; Saunderson, John R; Beavis, Andrew W

    2017-09-01

    The use of computer simulated digital x-radiographs for optimisation purposes has become widespread in recent years. To make these optimisation investigations effective, it is vital simulated radiographs contain accurate anatomical and system noise. Computer algorithms that simulate radiographs based solely on the incident detector x-ray intensity ('dose') have been reported extensively in the literature. However, while it has been established for digital mammography that x-ray beam quality is an important factor when modelling noise in simulated images there are no such studies for diagnostic imaging of the chest, abdomen and pelvis. This study investigates the influence of beam quality on image noise in a digital radiography (DR) imaging system, and incorporates these effects into a digitally reconstructed radiograph (DRR) computer simulator. Image noise was measured on a real DR imaging system as a function of dose (absorbed energy) over a range of clinically relevant beam qualities. Simulated 'absorbed energy' and 'beam quality' DRRs were then created for each patient and tube voltage under investigation. Simulated noise images, corrected for dose and beam quality, were subsequently produced from the absorbed energy and beam quality DRRs, using the measured noise, absorbed energy and beam quality relationships. The noise images were superimposed onto the noiseless absorbed energy DRRs to create the final images. Signal-to-noise measurements in simulated chest, abdomen and spine images were within 10% of the corresponding measurements in real images. This compares favourably to our previous algorithm where images corrected for dose only were all within 20%.

  18. Comparison between survey radiography, B-mode ultrasonography, contrast-enhanced ultrasonography and contrast-enhanced multi-detector computed tomography findings in dogs with acute abdominal signs.

    Science.gov (United States)

    Shanaman, Miriam M; Schwarz, Tobias; Gal, Arnon; O'Brien, Robert T

    2013-01-01

    Contrast-enhanced multi-detector computed tomography (CE-MDCT) is used routinely in evaluating human patients with acute abdominal symptoms. Contrast-enhanced ultrasound (CEUS) continues to be in its infancy as it relates to evaluation of the acute abdomen. The purpose of this study was to compare survey radiography, B-mode ultrasound, CEUS, and CE-MDCT findings in canine patients presenting with acute abdominal signs; with a focus on the ability to differentiate surgical from non-surgical conditions. Nineteen dogs were prospectively enrolled. Inclusion required a clinical diagnosis of acute abdominal signs and confirmed surgical or non-surgical causes for the clinical signs. Agreement for the majority of recorded imaging features was at least moderate. There was poor agreement in the identification of pneumoperitoneum and in the comparison of pancreatic lesion dimensions for B-mode vs. CEUS. The CT feature of fat stranding was detected in cases including, but not limited to, gastric neoplasia with perforation, pancreatitis, and small intestinal foreign body. Ultrasound underestimated the size and number of specific lesions when compared with CE-MDCT. Contrast-enhanced ultrasound was successful in detecting bowel and pancreatic perfusion deficits that CE-MDCT failed to identify. Accuracy for differentiation of surgical vs. non-surgical conditions was high for all modalities; 100%, 94%, and 94% for CE-MDCT, ultrasonography and survey radiography respectively. Findings indicated that CE-MDCT is an accurate screening test for differentiating surgical from non-surgical acute abdominal conditions in dogs. Focused CEUS following CE-MDCT or B-mode ultrasonography may be beneficial for identifying potentially significant hypoperfused lesions. © 2013 Veterinary Radiology & Ultrasound.

  19. Comparison of clinical values between cone beam computed tomography and conventional intraoral radiography in periodontal and infrabony defect assessment.

    Science.gov (United States)

    Suphanantachat, Supreda; Tantikul, Keenna; Tamsailom, Suphot; Kosalagood, Pasupen; Nisapakultorn, Kanokwan; Tavedhikul, Kanoknadda

    2017-08-01

    The use of CBCT for periodontal diagnosis and treatment plan is limited. The aim of this study is to compare the assessment of periodontal conditions and infrabony defects between conventional intraoral radiography (IOR) and CBCT. The study included 25 subjects who had periodontitis and at least two infrabony defects. All subjects received clinical periodontal examination, IOR and CBCT. Three periodontists assigned periodontal diagnosis and prognosis of each tooth. For teeth with infrabony defects, the number of defect walls and treatment was determined. IOR and CBCT assessment was compared. There were 666 teeth and 123 infrabony defects. The overall concordance between IOR and CBCT for periodontal diagnosis, prognosis, infrabony defect type and infrabony defect treatment were 79.3%, 69.5%, 44.7% and 64.2%, respectively. IOR underestimated diagnosis, prognosis and the number of infrabony defect walls at 16.4%, 24% and 37.4%, respectively. IOR and CBCT had poor concordance for periodontal regeneration (43.3%). Tooth extraction was more prevalent when assessed by CBCT (35.0% vs 22.7%). CBCT had excellent interexaminer agreement (Fleiss' kappa 0.87-0.94) and higher percentage of complete agreement among examiners than IOR for all assessments. IOR underestimated the severity and prognosis of periodontal disease. CBCT was superior to IOR for evaluation of infrabony defect morphology and treatment. CBCT provides excellent agreement among examiners on periodontal and infrabony defect assessment.

  20. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  1. Comparison of panoramic radiography and cone beam computed tomography for assessing the relationship between the maxillary sinus floor and maxillary molars

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Yun Hoa; Cho, Bong Hae [Department of Oral and Maxillofacial Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    2009-06-15

    This study compared panoramic radiography and cone beam computed tomography (CBCT) for evaluating the relationship between the maxillary sinus floor and the roots of maxillary molars. Paired panoramic radiographs and CBCT images from 97 subjects were analysed. This analysis classified 388 maxillary molars according to their relationship to the maxillary sinus floor on panoramic radiograph and CBCT. Correlations between these two radiographic techniques were examined. Maxillary molar roots that were separate from the sinus floor showed the same classification in 100% of the cases when using these two imaging techniques. The corresponding percentage for such roots that were in contact with the sinus floor was 75%. When roots overlapped the maxillary sinus floor on panoramic radiographs, only 26.4% of maxillary first molars and 60.0% of second molars showed protrusion of roots into the sinus with CBCT. The results of the study suggest that roots projecting into the sinus on panoramic radiographs require a three-dimensional image in order to analyze the proximity of their apex to the sinus floor.

  2. Improvement of lung abnormality detection in computed radiography using multi-objective frequency processing: Evaluation by receiver operating characteristics (ROC) analysis.

    Science.gov (United States)

    Tagashira, Hiroyuki; Arakawa, Kenji; Yoshimoto, Masahiro; Mochizuki, Teruhito; Murase, Kenya; Yoshida, Hiroyuki

    2008-03-01

    Computed radiography (CR) has been shown to have relatively low sensitivity for detection of pulmonary nodules. This poor sensitivity precludes its use as a screening modality despite the low cost, low dose and wide distribution of devices. The purpose of this study was to apply multi-objective frequency processing (MFP) to CR images and to evaluate its usefulness for diagnosing subtle lung abnormalities. Fifty CR images with simulated subtle lung abnormalities were obtained from 50 volunteers. Each image was processed with MFP. We cut chest images. The chest image was divided into two rights and left. A total of 200 half-chest images (100 MFP-processed images and 100 MFP-unprocessed images) were prepared. Five radiologists participated in this study. ROC analyses demonstrated that the detection rate of simulated subtle lung abnormalities on the CR images was significantly better with MFP (Az=0.8508) than without MFP (Az=0.7925). The CR images processed with MFP could be useful for diagnosing subtle lung abnormalities. In conclusion, MFP appears to be useful for increasing the sensitivity and specificity in the detection of pulmonary nodules, ground-glass opacity (GGO) and reticular shadow.

  3. Comparison of panoramic radiography and cone-beam computed tomography for qualitative and quantitative measurements regarding localization of permanent impacted maxillary canines

    Directory of Open Access Journals (Sweden)

    Çiğdem Sarıkır

    2017-01-01

    Full Text Available Objective: The purpose of this retrospective study was to compare the correlation between digital panoramic radiography (DPR and cone-beam computed tomography (CBCT evaluations for localization of impacted permanent maxillary canines (IPMCs and for other qualitative and quantitative parameters. Materials and Method: DPR and CBCT images of 60 patients (17 men and 43 women were examined independently by two observers. Correlations between DPR and CBCT images were evaluated regarding qualitative (bucco-palatal positioning of IPMCs, morphology and presence of root resorption of adjacent permanent lateral incisors, and contact relationship between IPMCs and adjacent permanent lateral incisors and quantitative (angle measurements variables. All evaluations were repeated 1 month later by each observer. Chi-square and t-tests were used for statistical analysis. Kappa statistics were used to assess intra- and interobserver agreement (Cohen’s κ. Results: No correlation was observed for determination of bucco-palatal positioning of IPMCs between DPR and CBCT images (p>0.05. Correlations were observed for other qualitative variables (p<0.05. Differences between DPR and CBCT images were seen for all examined quantitative variables (p<0.01. Intra- and interobserver agreements were substantial to almost-perfect. Conclusion: No significant correlation was found between DPR and CBCT images for determination of bucco-palatal positioning of IPMCs. All quantitative measurements performed on DPR and CBCT images significantly differed from each other.

  4. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    Directory of Open Access Journals (Sweden)

    Njeh Christopher F

    2012-03-01

    Full Text Available Abstract Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID or computed radiography (CR. We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence.

  5. Comparison of Micro-Computed Tomography and Digital Intraoral Radiography to Determine the Accuracy of Digital Radiographic Measurements of Mandibular Molar Teeth in Dogs.

    Science.gov (United States)

    Marron, Louise; Rawlinson, Jennifer; McGilvray, Kirk; Prytherch, Ben

    2017-12-01

    The purpose of this study was to compare root and root canal width measurements between digital intraoral radiography (IOR) and micro-computed tomography (μCT). The accuracy of IOR measurements of canine mandibular molars was scrutinized to assess feasibility of developing a model to estimate animal age based on dentinal thickness. Thirty-nine canine mandibular first molars were imaged using μCT and IOR. For each tooth, the root and root canal width of the mesial and distal roots were measured by a single observer at 3 marked sites on μCT and IOR. Two different software programs were used to measure the radiographs. The radiograph measurements were compared to each other and to the μCT measurements. The μCT images were considered the anatomic reference standard for structural representation. The data collected demonstrated IOR bias and variability throughout all measurement sites, with some sites being more affected than others. Neither IOR system produced unbiased measurements that closely reflected the μCT measurements consistently. The overall lack of agreement between measurements demonstrated the difficulties in developing a standardized protocol for measuring root and root canal width for the first molar teeth in dogs. Developing a protocol to accurately measure and compare μCT and IOR measurements is challenging. Designing a measurement system that would allow for universal application to age dogs would require continued research utilizing a standardized approach to overcome the limitations identified in this article.

  6. External root resorption of the second molar associated with third molar impaction: comparison of panoramic radiography and cone beam computed tomography.

    Science.gov (United States)

    Oenning, Anne Caroline Costa; Neves, Frederico Sampaio; Alencar, Phillipe Nogueira Barbosa; Prado, Rodrigo Freire; Groppo, Francisco Carlos; Haiter-Neto, Francisco

    2014-08-01

    The aim of the present study was to compare panoramic radiography and cone beam computed tomography (CBCT) for the assessment of external root resorption (ERR) of second molars associated with impacted third molars. In addition, the prevalence of ERR in second molars and the inclinations of the third molars more associated with ERR were investigated in both imaging methods. The sample consisted of 66 individuals with maxillary and mandibular impacted third molars (n = 188) seen on panoramic radiographs and CBCT images. The presence of ERR on the adjacent second molar was investigated, and the position of the third molar was determined using Winter's classification (vertical, horizontal, mesioangular, distoangular, and transverse). Statistical analysis was performed using the χ(2) test, Fisher exact test, and 2-proportion Z test (the significance level was set at 5%). A significantly greater number of cases of ERR (P third molars in mesioangular and horizontal inclinations were more likely to cause resorption of the adjacent teeth. CBCT should be indicated for the diagnosis of ERR in second molars when direct contact between the mandibular second and third molars has been observed on panoramic radiographs, especially in mesioangular or horizontal impactions. Furthermore, considering the propensity of these teeth to cause ERR in second molars, third molar prophylactic extraction could be suggested. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Analysis of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants; Analise da maxila edentula por meio da tomografia computadorizada e radiografia panoramica no planejamento cirurgico de implantes dentarios

    Energy Technology Data Exchange (ETDEWEB)

    Sahuinco, Humberto Lazaro Choquepuma; Souza, Ricardo Pires de [Complexo Hospitalar Heliopolis (HOSPHEL), Sao Paulo, SP (Brazil). Curso de pos-graduacao em Ciencias da Saude]. E-mail: humbertchs@hotmail.com

    2006-04-15

    Objective: to determine agreement of three observers on analysis of linear measurements of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants. Material and Method: the samples of 17 patients were analyzed with computed tomography and panoramic radiography. Linear measurements obtained from both methods were made at the following anatomical points: left tuberosity, left canine pillar, incisive foramen, right canine pillar and right tuberosity. Kendall's W test was applied to assess the level of agreement. Results: measured W-values from the samples of the anatomical points mentioned above, analyzed with panoramic radiography and computed tomography, were: 0.75 and 0.901; 0.916 and 0.956; 0.843 and 0.964; 0.963 and 0.931; 0.95 and 0.89 respectively. Statistical analysis showed that there was no statistically significant difference. Conclusion: agreement occurred in the measurements of variables.That means that if the three observers were to select an implant to be placed in each of the anatomical regions studied, there would be a good chance whey would choose the same type. (author)

  8. Radiography - A new field among health sciences in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Pakarinen, Ritva [Licentiate of Health Sciences, Department of Nursing Science and Health Administration, University of Oulu, Lamsantie 14 A1, 90230 Oulu (Finland)]. E-mail: ritva.pakarinen@oulu.fi; Jussila, Aino-Liisa [Doctor of Health Sciences, Department of Social and Health Care, Oulu Polytechnic, Oulu (Finland)

    2007-08-15

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population.

  9. Digital radiography: an overview.

    Science.gov (United States)

    Parks, Edwin T; Williamson, Gail F

    2002-11-15

    Since the discovery of X-rays in 1895, film has been the primary medium for capturing, displaying, and storing radiographic images. It is a technology that dental practitioners are the most familiar and comfortable with in terms of technique and interpretation. Digital radiography is the latest advancement in dental imaging and is slowly being adopted by the dental profession. Digital imaging incorporates computer technology in the capture, display, enhancement, and storage of direct radiographic images. Digital imaging offers some distinct advantages over film, but like any emerging technology, it presents new and different challenges for the practitioner to overcome. This article presents an overview of digital imaging including basic terminology and comparisons with film-based imaging. The principles of direct and indirect digital imaging modalities, intraoral and extraoral applications, image processing, and diagnostic efficacy will be discussed. In addition, the article will provide a list of questions dentists should consider prior to purchasing digital imaging systems for their practice.

  10. Evidence-based radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hafslund, Bjorg [Institute of Radiography, Faculty of Health and Social Sciences, Bergen University College, P.O. Box 7030, N-5020 Bergen (Norway)], E-mail: bhaf@hib.no; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica [Centre for Evidence Based Practice, Faculty of Health and Social Sciences, Bergen University College, Bergen (Norway)

    2008-11-15

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain.

  11. Technical Note: A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber.

    Science.gov (United States)

    Farace, Paolo; Righetto, Roberto; Deffet, Sylvain; Meijers, Arturs; Vander Stappen, Francois

    2016-12-01

    To introduce a fast ray-tracing algorithm in pencil proton radiography (PR) with a multilayer ionization chamber (MLIC) for in vivo range error mapping. Pencil beam PR was obtained by delivering spots uniformly positioned in a square (45 × 45 mm2 field-of-view) of 9 × 9 spots capable of crossing the phantoms (210 MeV). The exit beam was collected by a MLIC to sample the integral depth dose (IDDMLIC). PRs of an electron-density and of a head phantom were acquired by moving the couch to obtain multiple 45 × 45 mm2 frames. To map the corresponding range errors, the two-dimensional set of IDDMLIC was compared with (i) the integral depth dose computed by the treatment planning system (TPS) by both analytic (IDDTPS) and Monte Carlo (IDDMC) algorithms in a volume of water simulating the MLIC at the CT, and (ii) the integral depth dose directly computed by a simple ray-tracing algorithm (IDDdirect) through the same CT data. The exact spatial position of the spot pattern was numerically adjusted testing different in-plane positions and selecting the one that minimized the range differences between IDDdirect and IDDMLIC. Range error mapping was feasible by both the TPS and the ray-tracing methods, but very sensitive to even small misalignments. In homogeneous regions, the range errors computed by the direct ray-tracing algorithm matched the results obtained by both the analytic and the Monte Carlo algorithms. In both phantoms, lateral heterogeneities were better modeled by the ray-tracing and the Monte Carlo algorithms than by the analytic TPS computation. Accordingly, when the pencil beam crossed lateral heterogeneities, the range errors mapped by the direct algorithm matched better the Monte Carlo maps than those obtained by the analytic algorithm. Finally, the simplicity of the ray-tracing algorithm allowed to implement a prototype procedure for automated spatial alignment. The ray-tracing algorithm can reliably replace the TPS method in MLIC PR for in vivo range

  12. Multiple-image radiography

    Science.gov (United States)

    Wernick, Miles N.; Wirjadi, Oliver; Chapman, Dean; Zhong, Zhong; Galatsanos, Nikolas P.; Yang, Yongyi; Brankov, Jovan G.; Oltulu, Oral; Anastasio, Mark A.; Muehleman, Carol

    2003-12-01

    Conventional radiography produces a single image of an object by measuring the attenuation of an x-ray beam passing through it. When imaging weakly absorbing tissues, x-ray attenuation may be a suboptimal signature of disease-related information. In this paper we describe a new phase-sensitive imaging method, called multiple-image radiography (MIR), which is an improvement on a prior technique called diffraction-enhanced imaging (DEI). This paper elaborates on our initial presentation of the idea in Wernick et al (2002 Proc. Int. Symp. Biomed. Imaging pp 129-32). MIR simultaneously produces several images from a set of measurements made with a single x-ray beam. Specifically, MIR yields three images depicting separately the effects of refraction, ultra-small-angle scatter and attenuation by the object. All three images have good contrast, in part because they are virtually immune from degradation due to scatter at higher angles. MIR also yields a very comprehensive object description, consisting of the angular intensity spectrum of a transmitted x-ray beam at every image pixel, within a narrow angular range. Our experiments are based on data acquired using a synchrotron light source; however, in preparation for more practical implementations using conventional x-ray sources, we develop and evaluate algorithms designed for Poisson noise, which is characteristic of photon-limited imaging. The results suggest that MIR is capable of operating at low photon count levels, therefore the method shows promise for use with conventional x-ray sources. The results also show that, in addition to producing new types of object descriptions, MIR produces substantially more accurate images than its predecessor, DEI. MIR results are shown in the form of planar images of a phantom and a biological specimen. A preliminary demonstration of the use of MIR for computed tomography is also presented.

  13. Diagnostic accuracy of cone beam computed tomography compared with intraoral radiography for the detection of noncavitated occlusal carious lesions.

    Science.gov (United States)

    Krzyżostaniak, Joanna; Surdacka, Anna; Kulczyk, Tomasz; Dyszkiewicz-Konwińska, Marta; Owecka, Magdalena

    2014-01-01

    The aim of this study was to evaluate the accuracy of cone beam computed tomography (CBCT) in the detection of noncavitated occlusal caries lesions and to compare this accuracy with that observed with conventional radiographs. 135 human teeth, 67 premolars and 68 molars with macroscopically intact occlusal surfaces, were examined by two independent observers using the CBCT system: NewTom 3G (Quantitative Radiology) and intraoral conventional film (Kodak Insight). The true lesion diagnosis was established by histological examination. The detection methods were compared by means of sensitivity, specificity, predictive values and accuracy. To assess intra- and interobserver agreement, weighted kappa coefficients were computed. Analyses were performed separately for caries reaching into dentin and for all noncavitated lesions. For the detection of occlusal lesions extending into dentin, sensitivity values were lower for film (0.45) when compared with CBCT (0.51), but the differences were not statistically significant (p > 0.19). For all occlusal lesions sensitivity values were 0.32 and 0.22, respectively, for CBCT and film. The specificity scores were high for both modalities. Interobserver agreement amounted to 0.93 for the CBCT system and to 0.87 for film. It was concluded that the use of the 9-inch field of view NewTom CBCT unit for the diagnosis of noncavitated occlusal caries cannot be recommended. © 2014 S. Karger AG, Basel.

  14. Experimental study of the X-ray spectra optimization for computed radiography mammography systems; Investigacao experimental da otimizacao do espectro de raios X em sistemas de mamografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Tomal, Alessandra, E-mail: atomal@ifi.unicamp.br [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Instituto de Fisica Gleb Wataghin; Cunha, Diego M. [Universidade Federal de Uberlandia (UFU), Uberlandia, MG (Brazil). Instituto de Fisica; Nogueira, Maria S. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Gaspar, Fabio [Vigilancia Sanitaria, Campinas, SP (Brazil); Poletti, Martin E. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Departamento de Fisica

    2013-12-15

    Digital mammography is replacing screen-film mammography due to several advantages of digital receptors. The use of Computed Radiography (CR) mammography systems has been considered an alternative to achieve digital images with a low cost. Besides, the optimization of the X-ray spectrum, characterized by the anode/filter combination and tube potential, is an important step in order to improve the image quality with the lower dose to the breast. In this work, we investigated the optimal X-ray spectra using a figure of merit for two mammography equipment: Senographe DMR (General Electric Medical Systems) and Mammomat 3000 Nova (Siemens), both using an image plate Kodak EHR-M2 (Kodak DirectView). A PMMA phantom, simulating breast with thicknesses of 5 cm, was used. The anode/filter combinations evaluated were: Mo/Mo, Mo/Rh, Rh/Rh and Rh/Al for the Senographe system, and Mo/Mo, Mo/Rh, W/Rh for the Mammomat system, for all the intervals of tube potential range from 24 to 35 kVp. Results demonstrate that the higher values of FOM were achieved with the Rh/Rh at 29 kVp and Rh/Al at 26 kVp for the Senographe system, and for the W/Rh at 28 kVp in the Mammomat one. The reduction in the dose associated with the optimum spectra was 13 and 26% for the Senographe and Mammomat systems, respectively. Finally, our results suggest that anode/filter combinations of more energetic spectra than the standard Mo/Mo combination are recommended for thicker breast, in order to reduce the breast dose levels. (author)

  15. Physical and Clinical Comparison between a Screen-Film System and a Dual-Side Reading Mammography-Dedicated Computed Radiography System

    Energy Technology Data Exchange (ETDEWEB)

    Rivetti, S. (Dept. of Health Physics, AUSL Modena, Modena (Italy)). e-mail: nico.lanconelli@unibo.it; Canossi, B.; Battista, R.; Vetruccio, E.; Torricelli, P. (Dept. of Radiology, Univ. of Modena and Reggio Emilia, Modena (Italy)); Lanconelli, N. (Dept. of Physics, Univ. of Bologna, Bologna (Italy)); Danielli, C. (Dept. of Health Physics, Policlinico di Modena, Modena (Italy)); Borasi, G. (Dept. of Health Physics, Arcispedale Santa Maria Nuova, Reggio Emilia (Italy))

    2009-12-15

    Background: Digital mammography systems, thanks to a physical performance better than conventional screen-film units, have the potential of reducing the dose to patients, without decreasing the diagnostic accuracy. Purpose: To achieve a physical and clinical comparison between two systems: a screen-film plate and a dual-side computed radiography system (CRM; FUJIFILM FCR 5000 MA). Material and Methods: A unique feature of the FCR 5000 MA system is that it has a clear support medium, allowing light emitted during the scanning process to be detected on the 'back' of the storage phosphor plate, considerably improving the system's efficiency. The system's physical performance was tested by means of a quantitative analysis, with calculation of the modulation transfer function, detective quantum efficiency, and contrast-detail analysis; subsequently, the results were compared with those achieved using a screen-film system (SFM; Eastmann Kodak MinR-MinR 2000). A receiver operating characteristic (ROC) analysis was then performed on 120 paired clinical images obtained in a craniocaudal projection with the conventional SFM system under standard exposure conditions and also with the CRM system working with a dose reduced by 35% (average breast thickness: 4.3 cm; mean glandular dose: 1.45 mGy). CRM clinical images were interpreted both in hard copy and in soft copy. Results: The ROC analysis revealed that the performances of the two systems (SFM and CRM with reduced dose) were similar (P>0.05): the diagnostic accuracy of the two systems, when valued in terms of the area underneath the ROC curve, was found to be 0.74 for the SFM, 0.78 for the CRM (hard copy), and 0.79 for the CRM (soft copy). Conclusion: The outcome obtained from our experiments shows that the use of the dual-side CRM system is a very good alternative to the screen-film system

  16. Detection of furcation involvement using periapical radiography and 2 cone-beam computed tomography imaging protocols with and without a metallic post: An animal study

    Energy Technology Data Exchange (ETDEWEB)

    Salineiro, Fernanda Cristina Sales; Gialain, Ivan Onone; Kobayashi-Velasco, Solange; Pannuti, Claudio Mendes; Cavalcanti, Marcelo Gusmao Paraiso [Dept. of Stomatology, School of Dentistry, University of Sao Paulo, Sao Paulo (Brazil)

    2017-03-15

    The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.

  17. Comparison of intraoral radiography and cone-beam computed tomography for the detection of horizontal root fractures: an in vitro study.

    Science.gov (United States)

    Avsever, Hakan; Gunduz, Kaan; Orhan, Kaan; Uzun, Ismail; Ozmen, Bilal; Egrioglu, Erol; Midilli, Muhammed

    2014-01-01

    This study aimed to compare the diagnostic accuracy of two different cone-beam computed tomography (CBCT) units with several intraoral radiography techniques for detecting horizontal root fractures. The study material comprised 82 extracted human maxillary incisors without root fractures that had not undergone any root canal treatment. Root fractures were created in the horizontal plane in 31 teeth by a mechanical force using a hammer with the tooth placed on a soft foundation as described in a previous study. The teeth were divided into two groups: a control group with no fractures and a test group with fractures. These were randomized to the empty maxillary anterior sockets of a dry human maxilla. Each tooth was imaged at various vertical angles using each of the following modalities: a 3D Accuitomo 170 CBCT, a NewTom 3G CBCT, a VistaScan PSP, a CCD sensor, and conventional film. Specificity and sensitivity for assessing horizontal root fracture by each radiographic technique were calculated. Chi-square statistics were used to evaluate differences between modalities. Kappa statistics assessed the agreement between observers. Results were considered significant at P intraoral images. The diagnostic accuracy for detecting fracture lines in 3D Accuitomo 170 (0.93) was significantly higher than NewTom 3G (0.87), VistaScan (0.71), CCD (0.70), and CF (0.68). 3D Accuitomo 170 has the highest sensitivity and diagnostic accuracy for detecting horizontal root fracture among the 5 radiographic modalities examined. CBCT should be considered as the most reliable imaging modality of choice for the diagnosis of horizontal root fracture. CBCT imaging offers the clear advantage over conventional imaging that traumatized teeth can be visualized in all three dimensions--especially the oro-facial dimension.

  18. Differences in Healing of a Horizontal Root Fracture as Seen on Conventional Periapical Radiography and Cone-Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Ronnachat Rothom

    2017-01-01

    Full Text Available Different locations and healing patterns of horizontal root fractures bear different prognoses. Conventional periapical radiographs have been routinely used for the evaluation of the locations and healing of horizontal root fractures, with the limitation of presenting two-dimensional images. The three-dimensional imaging technology, cone-beam computed tomography (CBCT, has recently gained interest in dental traumatology, in particular for locating and diagnosing root fractures. However, the assessment of healing patterns of horizontal root fracture using CBCT compared to conventional radiographs has not been established. This case report describes the different healing patterns evaluated by two-dimensional radiographs and CBCT of a horizontally root-fractured maxillary right central incisor treated with mineral trioxide aggregate (MTA with a two-year follow-up. The findings suggest that the healing patterns of horizontal root fractures seen on conventional radiographs and CBCT may be different.

  19. Comparison of Cone-Beam Computed Tomography and Periapical Radiography in Predicting Treatment Decision for Periapical Lesions: A Clinical Study

    Directory of Open Access Journals (Sweden)

    Ashok Balasundaram

    2012-01-01

    Full Text Available Objectives. To compare the ability of endodontists to determine the size of apical pathological lesions and select the most appropriate choice of treatment based on lesions’ projected image characteristics using 2 D and 3 D images. Study Design. Twenty-four subjects were selected. Radiographic examination of symptomatic study teeth with an intraoral periapical radiograph revealed periapical lesions equal to or greater than 3 mm in the greatest diameter. Cone-beam Computed tomography (CBCT images were made of the involved teeth after the intraoral periapical radiograph confirmed the size of lesion to be equal to greater than 3 mm. Six observers (endodontists viewed both the periapical and CBCT images. Upon viewing each of the images from the two imaging modalities, observers (1 measured lesion size and (2 made decisions on treatment based on each radiograph. Chi-square test was used to look for differences in the choice of treatment among observers. Results. No significant difference was noted in the treatment plan selected by observers using the two modalities (χ2(3=.036, P>0.05. Conclusion. Lesion size and choice of treatment of periapical lesions based on CBCT radiographs do not change significantly from those made on the basis of 2 D radiographs.

  20. An evaluation of the periapical status of teeth with necrotic pulps using periapical radiography and cone-beam computed tomography.

    Science.gov (United States)

    Abella, F; Patel, S; Durán-Sindreu, F; Mercadé, M; Bueno, R; Roig, M

    2014-04-01

    To evaluate the presence or absence of periapical (PA) radiolucencies on individual roots of teeth with necrotic pulps, as assessed with digital PA radiographs and cone-beam computed tomography (CBCT). Digital PA radiographs and CBCT scans were taken from 161 endodontically untreated teeth (from 155 patients) diagnosed with non-vital pulps (pulp necrosis with normal PA tissue, symptomatic apical periodontitis, asymptomatic apical periodontitis, acute apical abscess and chronic apical abscess). Images were assessed by two calibrated endodontists to analyse the radiographic PA status of the teeth. A consensus was reached in the event of any disagreement. The data were analysed using a McNemar's test, and significance was set at P ≤ 0.05. Three hundred and forty paired images of roots were assessed with both digital PA radiographs and CBCT images. Fifteen additional roots were identified with CBCT. PA radiolucencies were present in 132 (38.8%) roots when assessed with PA radiographs, and in 196 (57.6%) roots when assessed with CBCT. This difference was statistically significant (P abscess, CBCT images revealed a statistically larger number of PA radiolucencies than did PA radiographs (P chronic apical abscess (P = 1). Unlike PA radiographs, CBCT revealed a higher prevalence of PA radiolucencies when endodontically untreated teeth with non-vital pulps were examined. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  1. A comparative study of cone beam computed tomography and conventional radiography in diagnosing the extent of root resorptions

    Directory of Open Access Journals (Sweden)

    Elham Alamadi

    2017-11-01

    Full Text Available Abstract Background Root resorptions are assessed and diagnosed using different radiographical techniques. A comparison of the ability to assess resorptions on two-dimensional (2D and three-dimensional (3D radiographs is, hitherto, lacking. The aims of this study were to evaluate the accuracy of 2D (periapical radiographs, PA and panoramic radiograph, PAN and 3D (cone beam computed tomography, CBCT radiographic techniques in measuring slanted root resorptions compared to the true resorptions, a histological gold standard, in addition to a comparison of all the radiographic techniques to each other. Methods Radiographs (CBCT, PA, and PAN, in addition to histological sections, of extracted deciduous canines from thirty-four patients were analyzed. Linear measurements of the most and least resorbed side of the root, i.e., “slanted” resorptions, were measured using an analyzing software (Facad ®. For classification of slanted root resorptions, a modified Malmgren index was used. Results PAN underestimated the root length on both the least and most resorbed side. Small resorptions, i.e., low modified Malmgren scores, were more difficult to record and were only assessed accurately using CBCT. The root resorption scores were underestimated using PA and PAN. In assessment of linear measures, PAN differed significantly from both CBCT and PA. Conclusions CBCT is the most accurate technique when measuring and scoring slanted root resorptions.

  2. The detection of periapical pathosis using periapical radiography and cone beam computed tomography - part 1: pre-operative status.

    Science.gov (United States)

    Patel, S; Wilson, R; Dawood, A; Mannocci, F

    2012-08-01

    Part 1 of this 2 part study aims to compare the prevalence of periapical lesions on individual roots viewed with intraoral (periapical) radiographs and cone-beam computed tomography (CBCT) of teeth treatment planned for endodontic treatment. Diagnostic periapical radiographs and CBCT scans were taken of 151 teeth in 132 patients diagnosed with primary endodontic disease. The presence or absence of periapical lesions was assessed by a consensus panel consisting of two calibrated examiners, a consensus agreement was reached if there was any disagreement. The panel viewed the images under standardised conditions. Part 2 will compare the radiographic outcome 1 year after completion of primary root canal treatment. Two hundred and seventy-three paired roots were assessed with both radiological systems, periapical lesions were present in 55 (20%) and absent in 218 (80%) roots assessed with periapical radiographs. When the same 273 sets of roots were assessed with CBCT, lesions were present in 130 (48%) and absent in 143 (52%) roots. Seventy-five additional roots were detected with CBCT. The limitations of periapical radiographs which may hinder the detection of periapical lesions are overcome with CBCT. This results in firstly, more roots being assessed, and secondly, more periapical lesions being detected with CBCT. © 2011 International Endodontic Journal.

  3. Identification of the Procedural Accidents During Root Canal Preparation Using Digital Intraoral Radiography and Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Csinszka K.-Ivácson A.-

    2016-09-01

    Full Text Available Crown or root perforation, ledge formation, fractured instruments and perforation of the roots are the most important accidents which appear during endodontic therapy. Our objective was to evaluate the value of digital intraoral periapical radiographs compared to cone beam computed tomography images (CBCT used to diagnose some procedural accidents. Material and methods: Eleven extracted molars were used in this study. A total of 18 perforations and 13 ledges were created artifically and 10 instruments were fractured in the root canals. Digital intraoral periapical radiographs from two angles and CBCT scans were made with the teeth fixed in position. The images were evaluated and the number of detected accidents were stated in percentages. Statistical analysis was performed using the chi square-test. Results: On digital periapical radiographs the evaluators identified 12 (66.66% perforations, 10 (100 % separated instruments and 10 (76.9% created ledges. The CBCT scans made possible the recognition of 17 (94.66 % perforations, 9 (90 % separated instruments and 13 (100% ledges. The totally recognized accidental procedures showed significant differences between the two groups. (p<0.05 Conclusion: Digital periapical radiographs are the most common imaging modalities used during endodontic treatments. Though, the CBCT allows a better identification of the procedural accidents.

  4. Evaluation of Cone Beam Computed Tomography (CBCT System: Comparison with Intraoral Periapical Radiography in Proximal Caries Detection

    Directory of Open Access Journals (Sweden)

    Solmaz Valizadeh

    2012-02-01

    Full Text Available Background and aims. With the introduction of Cone Beam Computed Tomography (CBCT in dentistry, a question has been raised whether the technique significantly increases the diagnostic accuracy in comparison with other techniques or not. Therefore, the present study was undertaken to assess the accuracy of CBCT modality in detecting proximal carious lesions as compared to conventional periapical radiographs. Materials and methods. This diagnostic study was carried out on 84 human extracted molars and premolars. The teeth were mounted and divided in 28 blocks of 3 teeth. Periapical and CBCT images of teeth were obtained. Five observers scored the images for the detection of proximal carious lesions using a 2-point scale (caries, present; caries, absent. The gold standard was determined by histopathologic sections. Sensitivity, specificity, PPV, NPV and receiver operating characteristics (ROC curves were traced for observers in both systems. The results were analyzed by paired t-test. Results. The area under the ROC curve, sensitivity, specificity, accuracy, positive and negative predictive values of CBCT images were 0.568, 0.835, 0.637, 0.714, 0.598 and 0.856, respectively. These parameters were 0.432, 0.837, 0.722, 0.77, 0.687 and 0.858 for the periapical conventional technique, respectively. Conclusion. The CBCT images did not enhance detection of proximal caries in comparison with periapical images.

  5. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    Background: Chest radiography is one of the most common examinations in radiology departments. In 2013 approximately 80,000 chest x-rays were performed on women in the fertile age. Even low dose for the examinationCorrect collimation Purpose: Quality improvement of basic radiography focusing...... on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...... of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance of clinical supervisors. Optimal collimation is determined by European...

  6. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik

    2015-01-01

    Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...... of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3...

  7. Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root-fractured permanent teeth.

    Science.gov (United States)

    Bornstein, Michael M; Wölner-Hanssen, Andrea B; Sendi, Pedram; von Arx, Thomas

    2009-12-01

    To compare intraoral occlusal (OC) and periapical (PA) radiographs vs. limited cone beam computed tomography (CBCT) in diagnosing root-fractured permanent teeth. In 38 patients (mean age 24 years, range 8-52 years) with 44 permanent teeth with horizontal root fractures, intraoral radiographs (PA and OC) and limited CBCT were used to evaluate the location (apical, middle, cervical third of the root) and angulation of the fracture line. Furthermore, the conventional radiographs and CBCT images were compared for concordance of fracture location. In the PA and OC radiographs, 28 fractures (63.6%) were located in the middle third of the root, 11 (25.0%) in the apical third and 5 (11.4%) in the cervical third. The PA/OC radiographs and the sagittal CBCT images (facial aspect) yielded the same level of root fracture in 70.5% of cases (31 teeth; 95% CI: 54.1-82.7%). The PA/OC radiographs and sagittal CBCT images (palatal aspect) showed the same level of root fracture in 31.8% of cases. There was a statistically significant association between the angle at which the root fracture line intersected the axis of the tooth and the level of root fracture in the facial aspect of the sagittal CBCT images. The diagnosis of the location and angulation of root fractures based on limited CBCT imaging differs significantly from diagnostic procedures based on intraoral radiographs (PA/OC) alone. The clinical significance for treatment strategies and for the prognosis of root-fractured teeth has to be addressed in future studies.

  8. Comparison of chest radiography and high-resolution computed tomography findings in early and low-grade coal worker's pneumoconiosis.

    Science.gov (United States)

    Savranlar, Ahmet; Altin, Remzi; Mahmutyazicioğlu, Kamran; Ozdemir, Hüseyin; Kart, Levent; Ozer, Tülay; Gündoğdu, Sadi

    2004-08-01

    High-resolution computed tomography (HRCT) is more sensitive than chest X-ray (CXR) in the depiction of parenchymal abnormalities. We aimed to present and compare CXR and HRCT findings in coal workers with and without early and low-grade coal worker's pneumoconiosis (CWP). 71 coal workers were enrolled in this study. All workers were male. The CXR and HRCT of those workers were obtained and graded by two trained readers. HRCT's were graded according to Hosoda and Shida's Japanese classification. After grading, 67 workers with CXR profusion 0/0-2/2 were included in the study. Four patients with major opacity were excluded. Profusion 0/1 to 1/1 cases were accepted as early and profusion 1/2 and 2/2 cases as low-grade pneumoconiosis. Discordance between CXR and HRCT was high. Discordance rate was found higher in the early pneumoconiosis cases with negative CXR than low-grade pneumoconiosis (60, 36 and 8%, respectively). When coal miners with normal CXR were evaluated by HRCT, six out of 10 cases were diagnosed as positive. In low-grade pneumoconiosis group, the number of patients with positive CXR but negative HRCT were low in comparison to patients with CXR negative and early pneumoconiosis findings. Most of the CXR category 0 patients (10/16) were diagnosed as category 1 by HRCT. Eleven cases diagnosed as CXR category 1 were diagnosed as category 0 (7/11) and category 2 (4/11) by HRCT. In CXR category 2 (eight cases), there were four cases diagnosed as category 1 by HRCT. Discordance between CXR and HRCT was high, especially for CXR negative and early pneumoconiosis cases. The role of CXR in screening coal workers to detect early pneumoconiosis findings should be questioned. We suggest using HRCT as a standard screening method instead of CXR to distinguish between normal and early pneumoconiosis.

  9. [Comparison of mesiodistal root angulation between panoramic radiography and reconstructed panoramic images from cone beam computed tomography].

    Science.gov (United States)

    Liu, Siqi; Wen, Fujia; Chen, Hua; Liu, Yi

    2014-01-01

    To evaluate the difference of mesiodistal root angulation between panoramic radiograph and panoramic images reconstructed from cone beam computed tomography (CBCT) by different methods. CBCT and panoramic radiograph of twenty patients were collected. The InvivoDental 5.0 was separately applied for maxillary or mandibular panoramic image reconstruction. The reconstruction method was combined by two head positions, the Frankfort plane horizontal position (P1) and the occlusal plane horizontal position (P2), and three central planes of focal trough (root apical plane, tooth center plane and crown marginal plane referring to the central incisor). Variation of tooth morphology in reconstructed panoramic images and panoramic radiograph was firstly observed. And then measurement for maxillary or mandibular anterior tooth intersection angle (contiguous angles among 321 123 were named as UA1-UA5; and those among 321 123 were named as LA1-LA5 ) was taken. The difference of intersection angles between reconstructed panoramic images and panoramic radiograph (ΔUA and ΔLA) were calculated. Wilcoxon Rank Sum Test was finally applied to compare the intersection angles' differences between P1 and P2 with the same central plane of focal trough. Panoramic images reconstructed from CBCT by tooth center plane with P1 for maxilla and P2 for mandible appeared to fulfill the clinically diagnostic demand through the observation. Among the 15 couples of comparison of intersection angles' differences between P1 and P2 by choosing the same central plane of focal trough for maxilla, 7 couples of ΔUA revealed a statistically smaller value in P1 while 1 couple of ΔUA showed an adverse result.In mandible with the same comparison method, 10 couples of comparison did not show statistical difference between P1 and P2, while 4 couples of ΔLA revealed a statistically smaller value in P2 and 1 couple ΔLA showed an opposite result. By choosing the tooth center plane, the panoramic images

  10. Performance of computed tomography versus chest radiography in patients with pulmonary tuberculosis with and without diabetes at a tertiary hospital in Riyadh, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Alkabab YM

    2018-01-01

    Full Text Available Yosra M Alkabab,1 Mushira A Enani,2 Nouf Y Indarkiri,3 Scott K Heysell1 1Department of Medicine, Division of Infectious Diseases and International Health, University of Virginia, Charlottesville, VA, USA; 2Department of Infectious Diseases, King Fahad Medical City, 3Department of Family Medicine, Prince Sultan Military Medical City, Riyadh, Saudi Arabia Background: Prior research suggests that diabetes mellitus (DM is associated with increasing risk for developing cavitary lung disease in patients with pulmonary tuberculosis (TB. Additionally, chest computed tomography (CT scan may be more sensitive than chest X-ray in detecting cavitary disease in such patients. The aim of this study was to compare the performance of chest CT to chest X-ray in detecting cavitary lung disease and to compare the frequency of cavities between TB patients with DM and without DM.Patients and methods: We conducted a retrospective cohort study at King Fahad Medical City, Riyadh, Saudi Arabia, from January 2004 to December 2015. We included patients aged 18 years and older with a positive sputum culture for Mycobacterium tuberculosis, and their medical charts were reviewed from admission to discharge.Results: Of the 133 patients who met the inclusion criteria, 38 (28.6% patients were known to have DM and were compared with 95 (71.4% patients without DM. DM patients with glycated hemoglobin (HbA1c >6.5% had significantly more cavitary lesions when compared to all patients (with or without DM with HbA1c <6.4% and/or random blood sugar <200 mg/dL. Furthermore, CT was able to detect lung cavities in 58.8% of the patients who had negative chest X-ray findings for cavities.Conclusion: The presence of lung cavities was significantly associated with the presence of DM and levels of HbA1c in patients with pulmonary TB. CT scan in those with normal radiography increased the detection of cavities. Keywords: diabetes, pulmonary tuberculosis, lung cavities, computed tomography

  11. EFFECTS OF X-RAY BEAM ANGLE AND GEOMETRIC DISTORTION ON WIDTH OF EQUINE THORACOLUMBAR INTERSPINOUS SPACES USING RADIOGRAPHY AND COMPUTED TOMOGRAPHY

    DEFF Research Database (Denmark)

    Djernaes, Julie D.; Nielsen, Jon V.; Berg, Lise C.

    2017-01-01

    The widths of spaces between the thoracolumbar processi spinosi (interspinous spaces) are frequently assessed using radiography in sports horses; however effects of varying X-ray beam angles and geometric distortion have not been previously described. The aim of this prospective, observational...

  12. Technical Note : A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber

    NARCIS (Netherlands)

    Farace, Paolo; Righetto, Roberto; Deffet, Sylvain; Meijers, Arturs; Vander Stappen, Francois

    2016-01-01

    Purpose: To introduce a fast ray-tracing algorithm in pencil proton radiography (PR) with a multilayer ionization chamber (MLIC) for in vivo range error mapping. Methods: Pencil beam PR was obtained by delivering spots uniformly positioned in a square (45x45 mm(2) field-of-view) of 9x9 spots capable

  13. Digital radiography image quality: image processing and display.

    Science.gov (United States)

    Krupinski, Elizabeth A; Williams, Mark B; Andriole, Katherine; Strauss, Keith J; Applegate, Kimberly; Wyatt, Margaret; Bjork, Sandra; Seibert, J Anthony

    2007-06-01

    This article on digital radiography image processing and display is the second of two articles written as part of an intersociety effort to establish image quality standards for digital and computed radiography. The topic of the other paper is digital radiography image acquisition. The articles were developed collaboratively by the ACR, the American Association of Physicists in Medicine, and the Society for Imaging Informatics in Medicine. Increasingly, medical imaging and patient information are being managed using digital data during acquisition, transmission, storage, display, interpretation, and consultation. The management of data during each of these operations may have an impact on the quality of patient care. These articles describe what is known to improve image quality for digital and computed radiography and to make recommendations on optimal acquisition, processing, and display. The practice of digital radiography is a rapidly evolving technology that will require timely revision of any guidelines and standards.

  14. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    2015-01-01

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...... of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance of clinical supervisors. Optimal collimation is determined by European...... collimations depending on side of radiograph. Results from dose reduction will be presented on the congress Conclusion: Correct positioning and collimation of digital chest radiographs can reduce the radiation dose significant to the patients and by that improve the quality of basic radiography....

  15. [An investigation of the effect of gamma rays emitted by patients undergoing radionuclide bone scintigraphy in computed radiography during X-ray mammography examination].

    Science.gov (United States)

    Kamigiri, Akira; Nagasawa, Naoki; Yamaji, Masami; Nakamura, Mikako; Ito, Morihiro; Nakanishi, Satoshi; Kitano, Tokio

    2010-03-20

    For convenience of outpatients, mammographies of outpatients are often taken after the injection of a radionuclide. In this study, we investigated the effects of gamma rays emitted by a patient onto imaging plates (IPs). We used a flat container filled with (99m)Tc solution as a planar source to irradiate gamma rays onto IPs. We changed irradiation times on each IP, and took radiographies of an ACR-specified 156 model phantom and AGH-D210F phantom. We evaluated radiography images, using visual evaluation, and profile curves, histograms, and CNR and RMS granularities analyses. The results indicated that the depiction ability of a fibrous part began to fall when the irradiation time exceeded 3 minutes. With an increase in irradiation time, an increase in pixel value and RMS granularity value and a decrease in CNR value were observed. In conclusion, IP exposed by gamma rays influenced the evaluation of phantom images.

  16. Investigation of physical imaging properties in various digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hoi Woun [Dept. of Radiological Science, Baekseok Culture University, Cheonan (Korea, Republic of); Min, Jung Hwan [Dept. of Radiological technology, Shingu University, Seongnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Kyushu (Japan); Kim, Jung Min [Dept. of Health and Environmental Science, College of Health Science, Korea University, Seoul (Korea, Republic of)

    2017-09-15

    We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

  17. Radiography at CERN

    CERN Multimedia

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  18. High-resolution computed tomography versus chest radiography in the diagnosis of interstitial lung disease in systemic sclerosis; Avaliacao da tomografia de alta resolucao versus radiografia de torax na doenca intersticial pulmonar na esclerose sistemica

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, Ana Beatriz Cordeiro de; Calderaro, Debora; Moreira, Caio [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Servico de Reumatologia; Guimaraes, Silvana Mangeon Meirelles [Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Secao de Tomografia Computadorizada; Tavares Junior, Wilson Campos; Leao Filho, Hilton Muniz; Andrade, Diego Correa de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Servico de Radiologia e Diagnostico por Imagem]. E-mail: wilsontavaresjrmd@yahho.fr; Ferreira, Cid Sergio; Vieira, Jose Nelson Mendes [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Medicina. Dept. de Radiologia

    2005-04-01

    Objective: To compare the accuracy of high-resolution computed tomography (HRCT) with chest radiography in the diagnosis of interstitial lung disease in systemic sclerosis (SSc). Materials And Methods: HRCT scans and chest radiographs in postero-anterior and lateral views were performed in 34 patients with systemic sclerosis, according to the American College of Rheumatology preliminary criteria for the diagnosis of SSc. The prevalence of radiological findings suggestive of interstitial lung disease in SSc seen on both imaging methods was compared. Results: Interstitial disease was observed on HRCT images of 31 patients (91%) and in the chest radiographs of 16 patients (47%). The most frequent findings observed on HRCT were septal lines (74%), honeycombing (56%) and parenchymal bands (26%). Chest radiographs showed reticular areas of attenuation in 11 patients (32%) and parenchymal distortion in 12% of the patients. In 18 patients (53%) with normal chest radiographs HRCT showed septal lines in 55%, ground glass in 44%, honeycombing in 38.5% and cysts in 33%. Conclusion: HRCT is more sensitive than chest radiography in the evaluation of incipient interstitial lung involvement in patients with SSc and can provide a justification for immunosuppressive therapy in patients with early disease. (author)

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  1. X-ray detectors for digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yaffe, M.J.; Rowlands, J.A. [Imaging Research Program, Sunnybrook Health Science Centre, University of Toronto, Toronto, ON (Canada)

    1997-01-01

    Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately inked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital radiography must meet the needs of the specific radiological procedure where they will be used. Key parameters are partial resolution, uniformity of response, contrast sensitivity, dynamic range, acquisition speed and frame rate. The underlying physical considerations defining the performance of x-ray detectors for radiography will be reviewed. Some of the more promising existing and experimental detector technologies which may be suitable for digital radiography will be considered. Devices that can be employed in full-area detectors and also those more appropriate for scanning x-ray systems will be discussed. These include various approaches based on phosphor x-ray converters, where light quanta are produced as an intermediate stage, as well as direct -ray-to-charge conversion materials such as zinc cadmium telluride, amorphous selenium and crystalline silicon. (author)

  2. Comprehensive Optimization Process of Paranasal Sinus Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Saarakkala, S. (Dept. of Clinical Radiology, Kuopio Univ. Hospital, Kuopio (Finland)); Nironen, K.; Hermunen, H.; Aarnio, J.; Heikkinen, J.O. (Dept. of Radiology, Etel-Savo Hospital District, Mikkeli Central Hospital, Mikkeli (Finland))

    2009-04-15

    Background: The optimization of radiological examinations is important in order to reduce unnecessary patient radiation exposure. Purpose: To perform a comprehensive optimization process for paranasal sinus radiography at Mikkeli Central Hospital (Finland). Material and Methods: Patients with suspicion of acute sinusitis were imaged with a Kodak computed radiography (CR) system (n=20) and with a Philips digital radiography (DR) system (n=30) using focus-detector distances (FDDs) of 110 cm, 150 cm, or 200 cm. Patients' radiation exposure was determined in terms of entrance surface dose and dose-area product. Furthermore, an anatomical phantom was used for the estimation of point doses inside the head. Clinical image quality was evaluated by an experienced radiologist, and physical image quality was evaluated from the digital radiography phantom. Results: Patient doses were significantly lower and image quality better with the DR system compared to the CR system. The differences in patient dose and physical image quality were small with varying FDD. Clinical image quality of the DR system was lowest with FDD of 200 cm. Further, imaging with FDD of 150 cm was technically easier for the technologist to perform than with FDD of 110 cm. Conclusion: After optimization, it was recommended that the DR system with FDD of 150 cm should always be used at Mikkeli Central Hospital. We recommend this kind of comprehensive approach in all optimization processes of radiological examinations.

  3. Effects of radiographic techniques on the low-contrast detail detectability performance of digital radiography systems.

    Science.gov (United States)

    Alsleem, Haney; U, Paul; Mong, Kam Shan; Davidson, Robert

    2014-01-01

    To evaluate the effects of the radiation exposure factors kilovolt peak and tube current time (milliampere seconds) on the low-contrast detail detectability performance of 3 types of planar digital radiography systems. Detectability performance of an imaging system refers to its ability to detect and present the low-contrast details of organs in the acquired image. The authors also compare detectability performance between computed radiography, indirect digital radiography, and direct digital radiography by evaluating low-contrast details of the obtained images. A low-contrast detail phantom was inserted within 10-cm thicknesses of Perspex plastic sheets. The images were obtained with various kilovolt peak and milliampere second settings for each of the 3 digital radiography systems. Artinis CDRAD Analyser software was used to score the images and calculate the inverse image quality figure (IQFinv). The higher milliampere second levels in each kilovolt peak selection resulted in higher IQFinv in computed radiography and indirect and direct digital radiography. IQFinv values significantly increased in indirect digital radiography with increasing kilovolt peak in only 1 and 2 mAs. There were insignificant differences in IQFinv values when altering kilovolt peak in each milliampere second level in direct digital radiography. The indirect digital radiography system generally demonstrated better detectability performance than computed radiography and direct digital radiography. However, direct digital radiography demonstrated better detectability performance than indirect digital radiography at lower kilovolt peak and milliampere second settings, as did computed radiography at lower kilovolt peak settings. Higher milliampere second settings increase photon count, which results in a higher signal-to-noise ratio and thus increased detectability. Lower milliampere second settings increase noise level on images, which increases the risk of diagnostic detail loss. Changing

  4. Progress in multiple-image radiography

    Science.gov (United States)

    Wernick, Miles N.; Brankov, Jovan G.; Chapman, Dean; Yang, Yongyi; Khelashvili, Gocha; Anastasio, Mark A.; Zhong, Zhong; Parham, Christopher; Li, Jun; Muehleman, Carol

    2006-02-01

    Conventional mammography is one of the most widely used diagnostic imaging techniques, but it has serious and well-known shortcomings, which are driving the development of innovative alternatives. Our group has been developing an x-ray imaging approach called multiple-image radiography (MIR), which shows promise as a potential alternative to conventional x-ray imaging (radiography). Like computed tomography (CT), MIR is a computed imaging technique, in which the images are not directly observed, but rather computed algorithmically. Whereas conventional radiography produces just one image depicting absorption effects, MIR simultaneously produces three images, showing separately the effects of absorption, refraction, and ultra-small-angle x-ray scattering. The latter two effects are caused by refractive-index variations in the object, which yield fine image details not seen in standard radiographs. MIR has the added benefits of dramatically lessening radiation dose, virtually eliminating scatter degradation, and lessening the importance of compressing the breast during imaging. In this paper we review progress to date on the MIR technique, focus on the basic physics and signal-processing issues involved in this new imaging method.

  5. Particle Beam Radiography

    Science.gov (United States)

    Peach, Ken; Ekdahl, Carl

    2014-02-01

    Particle beam radiography, which uses a variety of particle probes (neutrons, protons, electrons, gammas and potentially other particles) to study the structure of materials and objects noninvasively, is reviewed, largely from an accelerator perspective, although the use of cosmic rays (mainly muons but potentially also high-energy neutrinos) is briefly reviewed. Tomography is a form of radiography which uses multiple views to reconstruct a three-dimensional density map of an object. There is a very wide range of applications of radiography and tomography, from medicine to engineering and security, and advances in instrumentation, specifically the development of electronic detectors, allow rapid analysis of the resultant radiographs. Flash radiography is a diagnostic technique for large high-explosive-driven hydrodynamic experiments that is used at many laboratories. The bremsstrahlung radiation pulse from an intense relativistic electron beam incident onto a high-Z target is the source of these radiographs. The challenge is to provide radiation sources intense enough to penetrate hundreds of g/cm2 of material, in pulses short enough to stop the motion of high-speed hydrodynamic shocks, and with source spots small enough to resolve fine details. The challenge has been met with a wide variety of accelerator technologies, including pulsed-power-driven diodes, air-core pulsed betatrons and high-current linear induction accelerators. Accelerator technology has also evolved to accommodate the experimenters' continuing quest for multiple images in time and space. Linear induction accelerators have had a major role in these advances, especially in providing multiple-time radiographs of the largest hydrodynamic experiments.

  6. Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study.

    Science.gov (United States)

    Yılmaz, Funda; Kamburoğlu, Kıvanç; Şenel, Buğra

    2017-01-01

    The aim of this study was to evaluate the accuracy of working length determination by using an electronic apex locator, periapical radiography, and cone-beam computed tomographic (CBCT) imaging obtained at different voxel sizes and field of views (FOVs) in extracted human teeth. Thirty extracted human mandibular premolar teeth were used. The electronic working length measurements were performed by using an electronic apex locator (Root ZX; J Morita Corp, Kyoto, Japan). Five different image sets were obtained as follows: (1) CBCT imaging: 40 × 40 mm FOV, 0.080 mm3 (FOV40); (2) CBCT imaging: 60 × 60 mm FOV, 0.125 mm3 (FOV60); (3) CBCT imaging: 80 × 80 mm FOV, 0.160 mm3 (FOV80); (4) CBCT imaging: 100 × 100 mm FOV, 0.250 mm3 (FOV100); and (5) periapical digital radiography. Direct measurements performed with an electronic digital caliper were considered as the gold standard and compared with the electronic apex locator, CBCT, and periapical image measurements. Data were analyzed using a 2-way analysis of variance test. Significance level was set at P intraoral radiographs (P > .05 and the Gage R&R value was 30%). There were significant differences in the methods in terms of mean differences from the gold standard (P < .05). This study showed that available CBCT scans with different FOVs can be used for working length measurement. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. “Drug mules” as a radiological challenge: Sensitivity and specificity in identifying internal cocaine in body packers, body pushers and body stuffers by computed tomography, plain radiography and Lodox

    Energy Technology Data Exchange (ETDEWEB)

    Flach, Patricia M., E-mail: patricia.flach@irm.uzh.ch [Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, 3012 Bern (Switzerland); Department of Neuroradiology, Inselspital Bern, University of Bern, 3010 Bern (Switzerland); Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Department of Radiology, University Hospital USZ, University of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Ross, Steffen G. [Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, 3012 Bern (Switzerland); Ampanozi, Garyfalia; Ebert, Lars [Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, 3012 Bern (Switzerland); Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Germerott, Tanja; Hatch, Gary M. [Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, 3012 Bern (Switzerland); Thali, Michael J. [Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, 3012 Bern (Switzerland); Centre for Forensic Imaging and Virtopsy, Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057 Zurich (Switzerland); Patak, Michael A. [Department of Radiology, Inselspital Bern, University of Bern, 3010 Bern (Switzerland); Department of Radiology, University Hospital USZ, University of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2012-10-15

    Purpose: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox{sup ®}) in the detection of internal cocaine containers. Methods: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16–45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT = 35, nDR = 70, nLSDR = 30. An overall calculation of all “drug mules” and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. Results: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. Conclusions: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

  8. Description and comparison of excretory urography performed during radiography and computed tomography for evaluation of the urinary system in healthy New Zealand White rabbits (Oryctolagus cuniculus).

    Science.gov (United States)

    Vilalta, Laura; Altuzarra, Raul; Espada, Yvonne; Dominguez, Elisabet; Novellas, Rosa; Martorell, Jaime

    2017-04-01

    OBJECTIVE To evaluate the usefulness of excretory urography performed during radiography (REU) and CT (CTEU) in healthy rabbits, determine timings of urogram phases, and compare sensitivities of REU and CTEU for detection of these phases. ANIMALS 13 New Zealand White rabbits (Oryctolagus cuniculus). PROCEDURES Rabbits were screened for signs of systemic and urinary tract disease. An REU examination of each was performed, followed ≥ 5 days later by a CTEU examination. Contrast images from each modality were evaluated for quality of opacification and intervals between initiation of contrast medium administration and detection of various urogram phases. RESULTS Excretory urograms of excellent diagnostic quality were achieved with both imaging modalities. For all rabbits, the nephrographic phase of the urogram appeared in the first postcontrast REU image (obtained between 34 and 40 seconds after initiation of contrast medium administration) and at a median interval of 20 seconds in CTEU images. The pyelographic phase began at a median interval of 1.63 minutes with both imaging modalities. Contrast medium was visible within the urinary bladder at a median interval of 2.20 minutes. Median interval to the point at which the nephrogram and pyelogram were no longer visible in REU images was 8 hours and 2.67 hours, respectively. The CTEU technique was better than the REU technique for evaluating renal parenchyma. CONCLUSIONS AND CLINICAL RELEVANCE Findings suggested that REU and, particularly, CTEU may be valuable tools for the diagnosis of renal and urinary tract disease in rabbits; however, additional evaluation in diseased rabbits is required.

  9. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  10. Student Incivility in Radiography Education.

    Science.gov (United States)

    Clark, Kevin R

    2017-07-01

    To examine student incivility in radiography classrooms by exploring the prevalence of uncivil behaviors along with the classroom management strategies educators use to manage and prevent classroom disruptions. A survey was designed to collect data on the severity and frequency of uncivil student behaviors, classroom management strategies used to address minor and major behavioral issues, and techniques to prevent student incivility. The participants were educators in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology. Findings indicated that severe uncivil student behaviors in radiography classrooms do not occur as often as behaviors classified as less severe. Radiography educators in this study used a variety of strategies and techniques to manage and prevent student incivility; however, radiography educators who received formal training in classroom management reported fewer incidents of student incivility than those who had not received formal training. The participants in this study took a proactive approach to addressing severe behavioral issues in the classroom. Many radiography educators transition from the clinical environment to the classroom setting with little to no formal training in classroom management. Radiography educators are encouraged to attend formal training sessions to learn how to manage the higher education classroom effectively. Student incivility is present in radiography classrooms. This study provides a foundation for future research on incivility. ©2017 American Society of Radiologic Technologists.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) ... top of page What are some common uses of the procedure? A bone x-ray is used ...

  12. Proton radiography for clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Talamonti, C., E-mail: cinzia.talamonti@unifi.i [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Reggioli, V. [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); Bruzzi, M. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Dipartimento di Energetica, Universita degli Studi di Firenze, via S. Marta 3, I-50139 Firenze (Italy); Bucciolini, M. [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Civinini, C. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Marrazzo, L. [Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Menichelli, D. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Finland) (Italy); Dipartimento di Energetica, Universita degli Studi di Firenze, via S. Marta 3, I-50139 Firenze (Italy); Pallotta, S. [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Randazzo, N. [INFN, sezione di Catania, via S. Sofia 64, I-95123 Catania (Italy); Sipala, V. [INFN, sezione di Catania, via S. Sofia 64, I-95123 Catania (Italy); Dipartimento di Fisica, Universita degli Studi di Catania, via S. Sofia 64, I-95123 Catania (Italy)

    2010-01-11

    Proton imaging is not yet applied as a clinical routine, although its advantages have been demonstrated. In the context of quality assurance in proton therapy, proton images can be used to verify the correct positioning of the patient and to control the range of protons. Proton computed tomography (pCT) is a 3D imaging method appropriate for planning and verification of proton radiation treatments, because it allows evaluating the distributions of proton stopping power within the tissues and can be directly utilized when the patient is in the actual treatment position. The aim of the PRoton IMAging experiment, supported by INFN, and the PRIN 2006 project, supported by MIUR, is to realize a proton computed radiography (pCR) prototype for reconstruction of proton images from a single projection in order to validate the technique with pre-clinical studies and, eventually, to conceive the configuration of a complete pCT system. A preliminary experiment performed at the 250 MeV proton synchrotron of Loma Linda University Medical Center (LLUMC) allowed acquisition of experimental data before the completion of PRIMA project's prototype. In this paper, the results of the LLUMC experiment are reported and the reconstruction of proton images of two phantoms is discussed.

  13. Comparative of radiation dose and image quality of Conventional Multislice Computed Tomography (MSCT), Cone-Beam CT (CBCT) and periapical radiography in dental imaging

    OpenAIRE

    Nasrollah Jabbari; Seyyed Reza Mousavi; Kamal Firoozi

    2016-01-01

    Background and Aims: With the increasing use of CT (Computed Tomoghraphy) scans in dentistry especially in the implantology, there may be significant increases in the radiation exposure and its risk. During the last year’s ConeBeam Computed Tomoghraphy (CBCT) has been introduced as an imaging modality for dentistry. The aim of this review article was to present comprehensive information have been published, regarding the  radiation dose and image quality of Conventional Multis...

  14. Digital radiography versus conventional radiography during excretory urography: our experience

    Energy Technology Data Exchange (ETDEWEB)

    Cervi, P.M.; Bighi, S.; Merlo, L.; Lupi, L.; Vita, G. (S. Anna Hospital, FERRARA (IT))

    1990-01-01

    The authors describe a computed radiographic system employed to generate and archive digital images in intravenous urography. For each exposure the system produces two digital images: the first (left image) simulates a conventional screen-film radiograph, the second (right image); enhances some spatial frequencies and emphasizes the margins of the structures. These images can be modified in their chief parameters and then printed by a laser-printer and archived on optical disks. Four experienced radiologists evaluated digital images with regard to some chief diagnostic parameters and, in 50 patients, they compared digital images with conventional screen-film radiographs and submitted the results to statistical analysis. For some of the chosen parameters, particularly for the evaluation of renal margins before and after contrast medium injection, digital images gave statistically better results than conventional films, while, no statistically significant different was observed for the other parameters. From the results of this preliminary study digital radiography was found to be useful in intravenous urography by reducing the patient's exposition dose, by always obtaining images of good quality, and by enhancing some particular features of the standard image; on the other hand there were many unsolved problems regarding the communicating and archiving system (PACS), because of the slowness of the image transfer procedure, difficulties in data transmission and complexity of referential procedures.

  15. Mammographic scanning equalization radiography.

    Science.gov (United States)

    Sabol, J M; Soutar, I C; Plewes, D B

    1993-01-01

    It is well recognized that variations in breast thickness and parenchymal composition can produce a range of exposure which exceeds the latitude of high contrast mammographic film/screen combinations. Optimal imaging of the dense breast is desired since 30%-60% of women present with dense breasts, and they are believed to be at the highest relative risk of developing breast cancer. The application of scanning equalization radiography to mammography has been investigated through the construction and characterization of a prototype mammographic scanning equalization radiography (MSER) system, designed to image mammographic phantoms. The MSER system exposes a Min-R/MRH cassette by raster scanning a 2.0 x 1.6 cm beam of pulsed x-rays across the cassette. A scanning detector behind the cassette measures the local x-ray transmission of the breast. Feedback of the transmission information is used to modulate the duration of each x-ray pulse, to equalize the film exposure. The effective dynamic range of the MSER system is 25 times greater than that of conventional mammography. Artifact-free images of mammographic phantoms show that MSER effectively overcomes the latitude limitations of film/screen mammography, enabling high contrast imaging over a wide range of object x-ray transmission. Anthropomorphic phantom images show that MSER offers up to a sixfold increase in film contrast in the normally underexposed regions of conventional mammograms. Characterization of the entrance exposure shows that there is not a significant difference in exposure between MSER and conventional mammographic techniques, suggesting that both would pose comparable risk to the patient. Calculations show that the construction of a clinical multiple beam MSER system is feasible with minor changes to existing technology.

  16. [Report based on fiscal 2000 diagnostic x-ray equipment questionnaire survey(conditions of radiography)].

    Science.gov (United States)

    Ishikawa, Mitsuo; Matsuura, Takatoshi; Okuaki, Tomiyuki; Imai, Yoshio; Tsukamoto, Atsuko; Ide, Toshinori; Shinohara, Fuminori; Miyazaki, Shigeru

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film(S EF)in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations.

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  18. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... Media Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to X-ray (Radiography) - ...

  20. Proton Radiography (pRad)

    Data.gov (United States)

    Federal Laboratory Consortium — The proton radiography project has used 800 MeV protons provided by the LANSCE accelerator facility at LANL, to diagnose more than 300 dynamic experiments in support...

  1. Research on Advanced Nondestructive Evaluation (NDE) Methods for Materials, Process and Structures. Delivery Order 006: Computed Radiography Crack Detection Validation Study

    Science.gov (United States)

    2012-01-01

    Technical support provided by Greg Mohr NDT with various aspects of the program is greatly appreciated. The primary program contributors from UDRI...Sensitivity (EPS) standard ( ASTM E-746-07 [3]) was selected for use in the measurement of image noise and the Air Force Computed Radiog- 9 Approved...noise was characterized for the CR systems using EPS standards described in ASTM E-746-07, and shown schematically in Figure 2. However, due to the

  2. Optimization of process parameters in high-energy film radiography

    Science.gov (United States)

    Miller, Arthur C.; Cochran, Joseph L.

    2001-04-01

    Film radiography provides unequaled resolution for component and assembly inspection, certification, and quality evaluations. However, improvements can be made in our ability to identify defects and to obtain much more detail about fine features. A systematic approach to make incremental changes in current high-energy radiography may well provide the additional improvement needed. Consequently, the work described is concerned with optimizing important parameters affecting image quality. Modeling and simulation with advanced parallel computer systems provide a more detailed understanding of latent image formation at high x-ray energies and help explain image degradation mechanisms in enhancement screens.

  3. IMAGING DIAGNOSIS--USE OF RADIOGRAPHY AND COMPUTED TOMOGRAPHY IN THE DIAGNOSIS OF A MINERALIZED YOLK SAC IN A BROWN KIWI (APTERYX MANTELLI).

    Science.gov (United States)

    Wightman, Paul; Cohen, Eli B; Hunter, Stuart; Gartrell, Brett

    2015-01-01

    A 12-day-old Brown Kiwi (Apteryx mantelli) was presented with anorexia, torticollis, head-tilt, and coelomic distension. Radiographs showed an ill-defined, fat-opaque, coelomic mass displacing viscera craniodorsally. Curvilinear mineral opacities were superimposed over the ventral aspect of the mass. Computed tomography demonstrated the presence of mineral within the periphery of a fat attenuating mass consistent with a retained yolk sac. A deutectomy (yolk sac excision) was performed. Histopathology of the excised tissue confirmed the diagnosis of a retained yolk sac with multifocal mineralization. © 2014 American College of Veterinary Radiology.

  4. Unusual root morphology in second mandibular molar with a radix entomolaris, and comparison between cone-beam computed tomography and digital periapical radiography: a case report.

    Science.gov (United States)

    López-Rosales, Elisardo; Castelo-Baz, Pablo; De Moor, Roland; Ruíz-Piñón, Manuel; Martín-Biedma, Benjamín; Varela-Patiño, Purificación

    2015-09-22

    Radix entomolaris presents with an unusual morphology and is a rare occurrence. It is mainly observed in mandibular first molars. The incidence varies in different populations but it is far from common. This is especially true for mandibular second molars which possess the lowest prevalence. Some case reports have shown the presence of this finding in mandibular second molars; however, cases of patients of a white background have not been reported. The diagnosis and treatment of an infected radix entomolaris in a mandibular second molar in a 45-year-old white man is presented. The diagnosis was made with standard endodontic techniques. Conventional radiographic imaging was augmented with cone-beam computed tomography scans and three-dimensional images which were constructed with dedicated software. The endodontic treatment was done using accepted endodontic procedures. Clinical and radiographic evidence of healing was seen after a 14-month follow-up. The implications of complex and unpredictable root anatomy are discussed in this report. The clinician should consider the possibility of encountering a mandibular second molar with a radix entomolaris. Cone-beam computed tomography is a useful tool in the diagnosis and improvement of root canal therapy.

  5. Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques.

    Science.gov (United States)

    Campello, Andrea Fagundes; Gonçalves, Lucio Souza; Guedes, Fábio Ribeiro; Marques, Fábio Vidal

    2017-03-01

    The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chi-square test. The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions (P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

  6. Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

    Energy Technology Data Exchange (ETDEWEB)

    Campello, Abdrea Fagundes; Goncalves, Lucio Souza; Marques, Fabio vidal [Faculty of Dentistry, Estacio de Sa University, Rio de Janeiro (Brazil); Guedes, Fabio Ribeiro [Faculty of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2017-03-15

    The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using no.1/2, no.2, no.4, and no.6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chi-square test. The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions (P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

  7. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  8. An Ex Vivo Comparison of Digital Radiography, Cone Beam and Micro Computed Tomography in the Detection of the Number of Canals in the Mesiobuccal Roots of Maxillary Molars

    Science.gov (United States)

    Domark, Jeffrey D.; Hatton, John F.; Benison, Roxanne P.; Hildebolt, Charles F.

    2014-01-01

    Introduction The purpose of this study was to compare digital periapical and cone beam computed tomography (CBCT) images to determine the number of canals in the mesiobuccal root (MB) of maxillary molars and to compare these counts to micro CT (μCT), which was also used to determine canal configuration. Methods Digital periapical (RVG 6100), CBCT (9000 3D) and μCT images (the reference standard) were obtained of 18 hemi-maxillas. With periapical and CBCT images, 2 endodontists independently counted the number of canals in each molar and repeated counts 2 weeks later. Teeth were extracted, scanned with μCT, and 2 additional endodontists, by consensus, determined the number and configuration of canals. The Friedman test was used to test for differences. Results In mesiobuccal roots, 2 canals were present in 100% (13/13) of maxillary first and 57% (8/14) second molars, and 69% (9/13) and 100% (8/8) of these exited as two or more foramina. There was no difference in canal counts for original and repeat reads by the two observers with periapicals (P = 0.06) and with CBCT (P = 0.88) and no difference when CBCT counts were compared with μCT counts (P = 0.52); however, when periapical counts were compared with μCT counts there was a significant difference (P = 0.04). Conclusions For cadaver maxillary molars, μCT canal counts were significantly different from digital periapical radiograph counts but not different from Carestream 9000 3D CBCT counts. PMID:23791260

  9. Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography.

    Science.gov (United States)

    Han, Suchul; Lee, Boram; Shin, Gwisoon; Choi, Jonghak; Kim, Jungmin; Park, Changseo; Park, Hyok; Lee, Kisung; Kim, Youhyun

    2012-07-01

    In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dose-area product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm(2), respectively, were measured. In panoramic, cephalometric and cone beam computed tomography, the values were 120.3, 146 and 3203 mGy cm(2) (16 × 18 cm), respectively. It has been shown that, in intraoral radiography, the patient dose changes proportionally to the value of mA s, but the change in extraoral radiography in response to mA s could not be confirmed. The authors could confirm, however, the difference in dose according to the manufacturer in all dental radiography examinations, except for panoramic radiography. Depending on the size of hospital, there were some differences in patient dose in intraoral radiography, but no difference in patient dose in extraoral radiography.

  10. Digital Radiography: A Technology Overview

    Science.gov (United States)

    Arnold, Ben A.

    1982-12-01

    Digital radiography, a term hardly recognized two years ago, has grown to become the talk of the radiology community and the excitement of many commercial companies. M2st of this attention has been directed toward digital subtraction intravenous angiography), although during this same time period, a variety of digital radiography apparatus and image processing techniques have been under development. In November of 1980 at the RSNA Conference in Chicago, three commercial digital angiography systems were announced by Philips, Technicare and ADAC Corporations. During this same time period, the University of Arizona was discussing the concept of a photo electronic radiology department2, the University of Pittsburg and Stanford University were investigating line scan radiography3,4 and approximately five laboratories were carrying out clinical IV angiography with digital video systems.5-9 These developments followed basic research programs in digital electronic and computerized imaging at various locations around the world. 10-18 In the spring of 1981 we attempted to review the state of digital radiography, focusing on the various detector systems and image acquisition approaches.19 Since that time, rapid advancements in digital radiography have occurred. A major conference was held on digital radiography at Stanford UniversityzO, a new area detector system for digital radiography was announced by Fuji Film Corporation, clinical testing began on the Picker line scan digital chest unit21, and improvements were made in selenium detectors for digital radiography. Several additional companies announced digital video angiography systems, bringing the total now to approximately 15 companies worldwide. Digital video subtraction angiography is now well established as an important clinical diagnostic procedure and a variety of improvements and extensions of digital angiography systems are now ongoing. Digital acquisition and storage systems are increasing in both speed and

  11. TREAT neutron-radiography facility

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists.

  12. Procedimento educativo na epilepsia infantil Educational procedure in infantile epilepsy

    Directory of Open Access Journals (Sweden)

    Paula Teixeira Fernandes

    2001-06-01

    Full Text Available A epilepsia é uma condição neurológica crônica que afeta o comportamento do paciente e traz dificuldades psico-sócio-culturais. O trabalho em grupos visa melhorar a interação pais-filhos, através de informações adequadas sobre a epilepsia. O objetivo do presente trabalho foi, através dos grupos de apoio (procedimento educativo, esclarecer aspectos relacionados à epilepsia e avaliar a eficácia destes grupos na identificação e na melhora das variáveis psicológicas. Foram aplicados 36 protocolos (pré e pós-testes que avaliaram sentimentos, crenças e comportamentos dos pais e filhos. Foram observados sentimentos de mágoa e medo, tristeza e rejeição, que foram associados a superproteção e falta de limites. Depois do grupo, 91,6% dos pais relataram ter adquirido mais conhecimento sobre a epilepsia, associando muitas das dificuldades com a falta de informação e a presença de crenças irracionais. Conclui-se que orientação sobre a epilepsia, o uso de medicamentos, os aspectos psicológicos, sociais e comportamentais, melhoram a adaptação à doença. Por isso, a importância dos grupos na desmistificação de crenças, identificação de relações parentais e prevenção de dificuldades comportamentais.Epilepsy is a neurologic disorder, which affects the patient's behaviour and carries strong psychological, social and cultural difficulties. Group-work improves the interaction parent-child, through appropriate explanations regarding the epilepsy. The purpose of this study was to give adequate information about epilepsy through support groups (educational procedure and to assess the efficacy of these groups in identifying psychological aspects. Protocols were applied to 36 parents before and after the sessions, with questions concerning feelings and beliefs about epilepsy as well as parent-child interactions. As the main results, the following feelings were observed: fear, frightening and anxiety, sadness and rejection

  13. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... bear denotes child-specific content. Related Articles and Media ... Images related to X-ray (Radiography) - Bone Sponsored by ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ...

  17. REVIEW ARTICLE REVI REVI Computed radiography exposure ...

    African Journals Online (AJOL)

    entrance exposure to the plate and the digital signal indicators gener- ated by the system (SAL – scanning average ... image processing, independently of the applied dose. In fact, this is one of the key advantages of ... histogram of the digital image.4 These exposure indices are useful if the relationship with the air kerma is ...

  18. Repeat rates in digital chest radiography and strategies for improvement.

    Science.gov (United States)

    Fintelmann, Florian; Pulli, Benjamin; Abedi-Tari, Faezeh; Trombley, Maureen; Shore, Mary-Theresa; Shepard, Jo-Anne; Rosenthal, Daniel I

    2012-05-01

    To determine the repeat rate (RR) of chest radiographs acquired with portable computed radiography (CR) and installed direct radiography (DR) and to develop and assess strategies designed to decrease the RR. The RR and reasons for repeated digital chest radiographs were documented over the course of 16 months while a task force of thoracic radiologists, technologist supervisors, technologists, and information technology specialists continued to examine the workflow for underlying causes. Interventions decreasing the RR were designed and implemented. The initial RR of digital chest radiographs was 3.6% (138/3818) for portable CR and 13.3% (476/3575) for installed DR systems. By combining RR measurement with workflow analysis, targets for technical and teaching interventions were identified. The interventions decreased the RR to 1.8% (81/4476) for portable CR and to 8.2% (306/3748) for installed DR. We found the RR of direct digital chest radiography to be significantly higher than that of computed chest radiography. We believe this is due to the ease with which repeat images can be obtained and discarded, and it suggests the need for ongoing surveillance of RR. We were able to demonstrate that strategies to lower the RR, which had been developed in the era of film-based imaging, can be adapted to the digital environment. On the basis of our findings, we encourage radiologists to assess their own departmental RRs for direct digital chest radiography and to consider similar interventions if necessary to achieve acceptable RRs for this modality.

  19. Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation

    OpenAIRE

    Saltybaeva, Natalia; Krauss, Andreas; Alkadhi, Hatem

    2016-01-01

    Purpose To calculate the effect of localizer radiography projections to the total radiation dose, including both the dose from localizer radiography and that from subsequent chest computed tomography (CT) with tube current modulation (TCM). Materials and Methods An anthropomorphic phantom was scanned with 192-section CT without and with differently sized breast attachments. Chest CT with TCM was performed after one localizer radiographic examination with anteroposterior (AP) or posteroanterio...

  20. Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography.

    Science.gov (United States)

    Kamburoglu, K; Kolsuz, E; Murat, S; Yüksel, S; Ozen, T

    2012-09-01

    To compare proximal caries detection using intraoral bitewing, extraoral bitewing and panoramic radiography. 80 extracted human premolar and molar teeth with and without proximal caries were used. Intraoral radiographs were taken with Kodak Insight film (Eastman Kodak Co., Rochester, NY) using the bitewing technique. Extraoral bitewing and panoramic images were obtained using a Planmeca Promax Digital Panoramic X-ray unit (Planmeca Inc., Helsinki, Finland). Images were evaluated by three observers twice. In total, 160 proximal surfaces were assessed. Intra- and interobserver kappa coefficients were calculated. Scores obtained from the three techniques were compared with the histological gold standard using receiver operating characteristic analysis. Az values for each image type, observer and reading were compared using z-tests, with a significance level of α = 0.05. Kappa coefficients ranged from 0.883 to 0.963 for the intraoral bitewing, from 0.715 to 0.893 for the extraoral bitewing, and from 0.659 to 0.884 for the panoramic radiography. Interobserver agreements for the first and second readings for the intraoral bitewing images were between 0.717 and 0.780, the extraoral bitewing readings were between 0.569 and 0.707, and the panoramic images were between 0.477 and 0.740. The Az values for both readings of all three observers were highest for the intraoral bitewing. Az values for the extraoral bitewing images were higher than those of the panoramic images without statistical significance (p > 0.05). Intraoral bitewing radiography was superior to extraoral bitewing and panoramic radiography in diagnosing proximal caries of premolar and molar teeth ex vivo. Similar intra- and interobserver coefficients were calculated for extraoral bitewing and panoramic radiography.

  1. Do we really need kidneys-ureters-bladder radiography to predict stone radiopacity before treatment with shockwave lithotripsy? Development and internal validation of a novel predictive model based on computed tomography parameters.

    Science.gov (United States)

    Sfoungaristos, Stavros; Hidas, Guy; Gofrit, Ofer N; Yutkin, Vladimir; Latke, Arie; Landau, Ezekiel H; Pode, Dov; Duvdevani, Mordechai

    2015-05-01

    To produce and validate a predictive model based on CT parameters for calculating the probability of a stone to be visible on fluoroscopy of shockwave lithotripsy (SWL) and to compare its accuracy to that of kidneys-ureters-bladder (KUB) radiography. We retrospectively analyzed 306 patients (sample group) who underwent an SWL between March 2011 and August 2012. A multivariate analysis of several parameters extracted from the preoperative CT scan was conducted to identify independent predictors for radiopacity on SWL fluoroscopy. The results were used for the creation of a predictive model. Internal validation was made on a group of 75 patients (validation group) treated from September 2012 until December 2012. Predictive accuracy of the model was evaluated by receiver operating characteristic (ROC) curve and calibration plot. The ROC curve was also used for comparing the predictive accuracy of the model to that of KUB radiography. From 306 evaluated stones, 238 (77.8%) were visible on fluoroscopy. Results of the multivariate analysis revealed that stone size (Ppredictive model was produced based on the above parameters. The model demonstrated high calibration and areas under the curve of 0.923 and 0.965 in the sample and validation group, respectively, while its predictive performance was significantly higher (Pmodel can estimate with high accuracy stone radiopacity on SWL fluoroscopy using parameters of CT scan and thus it can be used as an alternative to KUB radiography for treatment planning.

  2. System for uncollimated digital radiography

    Science.gov (United States)

    Wang, Han; Hall, James M.; McCarrick, James F.; Tang, Vincent

    2015-08-11

    The inversion algorithm based on the maximum entropy method (MEM) removes unwanted effects in high energy imaging resulting from an uncollimated source interacting with a finitely thick scintillator. The algorithm takes as input the image from the thick scintillator (TS) and the radiography setup geometry. The algorithm then outputs a restored image which appears as if taken with an infinitesimally thin scintillator (ITS). Inversion is accomplished by numerically generating a probabilistic model relating the ITS image to the TS image and then inverting this model on the TS image through MEM. This reconstruction technique can reduce the exposure time or the required source intensity without undesirable object blurring on the image by allowing the use of both thicker scintillators with higher efficiencies and closer source-to-detector distances to maximize incident radiation flux. The technique is applicable in radiographic applications including fast neutron, high-energy gamma and x-ray radiography using thick scintillators.

  3. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  4. Contribution of computed tomography in patients with lung metastases of differentiated thyroid carcinoma not apparent on plain radiography who were treated with radioiodine; Contribuicao da tomografia computadorizada em pacientes com metastases pulmonares de carcinoma diferenciado de tireoide nao-aparentes na radiografia e tratados com radioiodo

    Energy Technology Data Exchange (ETDEWEB)

    Rosario, Pedro W.S.; Purisch, Saulo [Santa Casa Belo Horizonte, MG (Brazil). Dep. de Tireoide. Servico de Endocrinologia]. E-mail: pedrorosario@globo.com; Tavares, Wilson C. [Instituto Alpha de Gastroenterologia, Belo Horizonte, MG (Brazil); Barroso, Alvarao L.; Rezende, Leonardo L.; Padrao, Eduardo L. [Santa Casa Belo Horizonte, MG (Brazil). Servico de Medicina Nuclear

    2008-02-15

    Computed tomography (CT or CAT Scan) of the chest is more sensitive than radiography in the detection of lung metastases of differentiated thyroid cancer (DTC), but little information is available regarding the aggregated value of this method. The present study evaluated the response of patients with lung metastases of DTC not apparent on radiography to treatment with {sup 131}I and the value of CT in these cases. Twenty-five patients with lung metastases not apparent on radiography, who initially received 100-200 mCi I{sup 151}, were evaluated and those presenting pulmonary uptake on post-therapy WBS were submitted to a new treatment after 6 to 12 months, and so on. The chance of detection of pulmonary uptake on post-therapy WBS did not differ between patients with negative and positive CT (100% versus 91.5%). Mean serum Tg levels were higher in patients with positive CT (108 ng/ml versus 52 ng/ml). Negative post-therapy WBS was achieved in 82% of patients with positive CT and in 92.3% with negative CT and the cumulative I{sup 131} activity necessary to achieve this outcome did not differ between the two groups (mean = 300 mCi). Stimulated Tg was undetectable in 47% of patients with negative CT at the end of treatment, but in none of the patients whose CT continued to be positive. In patients with elevated Tg, the CT result apparently did not change the indication of therapy or the I{sup 131} activity to be administered. In cases with lung metastases, the persistence of micronodules on CT was associated with the persistence of detectable Tg in patients presenting negative post-therapy WBS. (author)

  5. Índice de mortalidade durante procedimentos anestésicos: estudo retrospectivo (1996-2006)

    OpenAIRE

    Corrêa, André Luís; Oleskovicz,Nilson; Moraes,Aury Nunes de

    2009-01-01

    O objetivo deste estudo é reportar a incidência de óbitos anestésico-cirúrgicos durante um período de 11 anos (1996-2006), no qual não eram realizados exames complementares e/ou laboratoriais previamente ao encaminhamento para anestesia. Dessa forma, realizou-se um estudo retrospectivo, avaliando-se as fichas anestésicas utilizadas durante os procedimentos realizados no Hospital de Clínica Veterinária (HCV) da Universidade do Estado de Santa Catarina (UDESC). Analisaram-se 7.012 procedimentos...

  6. Digital radiography: update for oral health care workers.

    Science.gov (United States)

    Noffke, C E E; Nzima, N; Chabikuli, N J

    2004-08-01

    Digital Radiography is an imaging system that does away with the use of films. It constitutes an advance in computer technology and has made a significant impact on the field of Maxillofacial- and Dental Radiology. This paper presents an overview of the basic concepts and applications of dental digital radiography and compares it with conventional film-based imaging. In addition, it provides a thorough understanding of the direct, semi-direct and indirect dental digital imaging systems with their advantages and disadvantages. Universal acceptance of digital radiographic imaging as a diagnostic tool makes it important for oral health care workers to understand the principles thereof and to master the techniques involved in acquiring a diagnosable digital radiographic image.

  7. A PROBLEMÁTICA DA TEMPERATURA CORPORAL ENQUANTO UM PROCEDIMENTO DE ENFERMAGEM: CONCEITOS E MECANISMOS REGULADORES

    Directory of Open Access Journals (Sweden)

    Maria Teresa Cícero Laganá

    Full Text Available O presente estudo mostra a problemática da temperatura corporal enquanto um procedimento de enfermagem. Apresenta conceitos relacionados à temperatura e suas alterações, e descreve duas entidades nosológicas relacionadas com a elevação da temperatura: febre e hipertermia maligna.

  8. Multiple imaging radiography at LNLS

    Energy Technology Data Exchange (ETDEWEB)

    Hoennicke, M.G. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba (Brazil)], E-mail: marcelohonnicke@yahoo.com.br; Cusatis, C. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba(Brazil); Antunes, A. [Departamento de Fisica Aplicada, Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318, 05315-970 Sao Paulo (Brazil); Safatle, A.M.V.; Barros, P.S.M. [Laboratorio de Oftalmologia Experimental e Comparativa, Departamento de Cirurgia, Faculdade de Medicina Veterinaria, Universidade de Sao Paulo, 05508-900 Sao Paulo (Brazil); Morelhao, S.L. [Departamento de Fisica Aplicada, Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318, 05315-970 Sao Paulo (Brazil)

    2008-01-11

    An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

  9. Dual-kVp Radiography

    Science.gov (United States)

    Brody, William R.; Sommer, F. Graham; Lehmann, Leonard A.; Macovski, Albert; Alvarez, Robert E.; Pelc, Norbert J.; Riederer, Stephen J.; Hall, Anne

    1981-07-01

    The use of information contained in the transmitted x-ray spectrum provides the capability for selective removal of substances of a particular mean atomic number in projection radiographs. Using a prototype system for line-scanned digital radiography, x-ray images were produced with two different x-ray spectra by modulating the kVp applied to the x-ray source and filtering the x-ray beam. Using a previously described Compton/photoelectric decomposition algorithm, subtraction images are made with bone or soft-tissue (water) shadows removed. Applications to chest, abdominal and skeletal imaging in-vivo are demonstrated.

  10. Better imaging: the advantages of digital radiography

    NARCIS (Netherlands)

    van der Stelt, P.F.

    2008-01-01

    Background. Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because

  11. INDUSTRIAL RADIOGRAPHY STUDENT GUIDE AND LABORATORY EXERCISES.

    Science.gov (United States)

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS INSTRUCTOR'S GUIDE TO AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY IS COORDINATED WITH LESSONS IN THE STUDENT GUIDE AND LABORATORY EXERCISES AND IS BASED ON MATERIAL IN THE COURSE MANUAL, INDUSTRIAL RADIOGRAPHY. THE COURSE IS INTENDED TO TRAIN HIGH SCHOOL GRADUATES AS BEGINNING RADIOGRAPHERS WHO ARE EXPECTED TO BE ABLE TO EXTEND THEIR…

  12. PROTON RADIOGRAPHY FOR AN ADVANCED HYDROTEST FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    C. MORRIS

    2000-11-01

    Analysis of data from BNL experiment 933 is presented. Results demonstrate that proton radiography can meet many of the requirements for an Advanced Hydrotest Facility (AHF). Results for background, position resolution, metrology, quantitative radiography, material identification, and edge resolution are presented.

  13. Digital chest radiography: collimation and dose reduction

    DEFF Research Database (Denmark)

    Debess, Jeanne; Johnsen, Karen Kirstine; Vejle-Sørensen, Jens Kristian

    Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...... of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3...

  14. Detection failure rate of chest radiography for the identification of nursing and healthcare-associated pneumonia.

    Science.gov (United States)

    Miyashita, Naoyuki; Kawai, Yasuhiro; Tanaka, Takaaki; Akaike, Hiroto; Teranishi, Hideto; Wakabayashi, Tokio; Nakano, Takashi; Ouchi, Kazunobu; Okimoto, Niro

    2015-07-01

    To clarify the detection failure rate of chest radiography for the identification of nursing and healthcare-associated pneumonia (NHCAP), we compared high-resolution computed tomography (HRCT) with chest radiography simultaneously for patients with clinical symptoms and signs leading to a suspicion of NHCAP. We analyzed 208 NHCAP cases and compared them based on four groups defined using NHCAP criteria, patients who were: Group A) resident in an extended care facility or nursing home; Group B) discharged from a hospital within the preceding 90 days; Group C) receiving nursing care and had poor performance status; and Group D) receiving regular endovascular treatment. Chest radiography was inferior to HRCT for the identification of pneumonia (149 vs 208 cases, p detection failure rate of chest radiography differed among NHCAP criteria; 27.8% in Group A, 26.5% in Group B, 36.7% in Group C and 5.8% in Group D. Cerebrovascular disease and poor functional status were significantly more frequent in patients in Groups A and C compared with those in Groups B and D. Physicians may underestimate pneumonia shadow in chest radiographs in patients with NHCAP, and the detection failure rate of chest radiography differed among NHCAP criteria. Poor functional status may correlate with the low accuracy of chest radiography in diagnosing pneumonia. Copyright © 2015. Published by Elsevier Ltd.

  15. Validation of the sensitivity of the National Emergency X-Radiography Utilization Study (NEXUS Head computed tomographic (CT decision instrument for selective imaging of blunt head injury patients: An observational study.

    Directory of Open Access Journals (Sweden)

    William R Mower

    2017-07-01

    Full Text Available Clinicians, afraid of missing intracranial injuries, liberally obtain computed tomographic (CT head imaging in blunt trauma patients. Prior work suggests that clinical criteria (National Emergency X-Radiography Utilization Study [NEXUS] Head CT decision instrument [DI] can reliably identify patients with important injuries, while excluding injury, and the need for imaging in many patients. Validating this DI requires confirmation of the hypothesis that the lower 95% confidence limit for its sensitivity in detecting serious injury exceeds 99.0%. A secondary goal of the study was to complete an independent validation and comparison of the Canadian and NEXUS Head CT rules among the subgroup of patients meeting the inclusion and exclusion criteria.We conducted a prospective observational study of the NEXUS Head CT DI in 4 hospital emergency departments between April 2006 and December 2015. Implementation of the rule requires that patients satisfy 8 criteria to achieve "low-risk" classification. Patients are excluded from "low-risk" classification and assigned "high-risk" status if they fail to meet 1 or more criteria. We examined the instrument's performance in assigning "high-risk" status to patients requiring neurosurgical intervention among a cohort of 11,770 blunt head injury patients. The NEXUS Head CT DI assigned high-risk status to 420 of 420 patients requiring neurosurgical intervention (sensitivity, 100.0% [95% confidence interval [CI]: 99.1%-100.0%]. The instrument assigned low-risk status to 2,823 of 11,350 patients who did not require neurosurgical intervention (specificity, 24.9% [95% CI: 24.1%-25.7%]. None of the 2,823 low-risk patients required neurosurgical intervention (negative predictive value [NPV], 100.0% [95% CI: 99.9%-100.0%]. The DI assigned high-risk status to 759 of 767 patients with significant intracranial injuries (sensitivity, 99.0% [95% CI: 98.0%-99.6%]. The instrument assigned low-risk status to 2,815 of 11

  16. Dedicated phantom materials for spectral radiography and CT.

    Science.gov (United States)

    Shikhaliev, Polad M

    2012-03-21

    As x-ray imaging technology moves from conventional radiography and computed tomography (CT) to spectral radiography and CT, dedicated phantom materials are needed for spectral imaging. The spectral phantom materials should accurately represent the energy-dependent mass-attenuation coefficients of different types of tissues. Although tissue-equivalent phantom materials were previously developed for CT and radiation therapy applications, these materials are suboptimal for spectral radiography and CT; they are not compatible with contrast agents, do not represent many of the tissue types and do not provide accurate values of attenuation characteristics of tissue. This work provides theoretical framework and a practical method for developing tissue-equivalent spectral phantom materials with a required set of parameters. The samples of the tissue-equivalent spectral phantom materials were developed, tested and characterized. The spectral phantom materials were mixed with iodine, gold and calcium contrast agents and evaluated. The materials were characterized by CT imaging and x-ray transmission experiments. The fabricated materials had nearly identical densities, mass attenuation coefficients, effective atomic numbers and electron densities as compared to corresponding tissue materials presented in the ICRU-44 report. The experimental results have shown good volume uniformity and inter-sample uniformity (repeatability of sample fabrication) of the fabricated materials. The spectral phantom materials were fabricated under laboratory conditions from readily available and inexpensive components. It was concluded that the presented theoretical framework and fabrication method of dedicated spectral phantom materials could be useful for researchers and developers working in the new area of spectral radiography and CT. Independently, the results could also be useful for other applications, such as radiation therapy. © 2012 Institute of Physics and Engineering in Medicine

  17. The integral dose in panoramic intraoral x-ray tube radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hayami, A.; Fujishita, M.; Sumida, A.; Kanke, M.; Fujiki, T.; Uemura, S.; Fuchihata, H.

    1983-07-01

    A Monte Carlo computer program was developed to estimate the integral dose to the head and thyroid for panoramic intraoral x-ray tube radiography. The advantage of this computer simulation is that it is able to avoid many of the difficulties associated with low-energy and low-dose x-ray dosimetry. The calculations were made for maxillary and mandibular projections separately, using 10 kv. increments between 40 and 60 kv. The results obtained were presented in terms of the integral dose per milliampere second. Typical integral doses for a routine examination of the head are 2.1 mJ. and 8.5 microJ for the thyroid during mandibular radiography and 1.7 microJ for the thyroid during radiography of the maxilla using 55 kv. and 0.5 mAs.

  18. Review of medical radiography and tomography with proton beams

    Science.gov (United States)

    Johnson, Robert P.

    2018-01-01

    The use of hadron beams, especially proton beams, in cancer radiotherapy has expanded rapidly in the past two decades. To fully realize the advantages of hadron therapy over traditional x-ray and gamma-ray therapy requires accurate positioning of the Bragg peak throughout the tumor being treated. A half century ago, suggestions had already been made to use protons themselves to develop images of tumors and surrounding tissue, to be used for treatment planning. The recent global expansion of hadron therapy, coupled with modern advances in computation and particle detection, has led several collaborations around the world to develop prototype detector systems and associated reconstruction codes for proton computed tomography (pCT), as well as more simple proton radiography, with the ultimate intent to use such systems in clinical treatment planning and verification. Recent imaging results of phantoms in hospital proton beams are encouraging, but many technical and programmatic challenges remain to be overcome before pCT scanners will be introduced into clinics. This review introduces hadron therapy and the perceived advantages of pCT and proton radiography for treatment planning, reviews its historical development, and discusses the physics related to proton imaging, the associated experimental and computation issues, the technologies used to attack the problem, contemporary efforts in detector and computational development, and the current status and outlook.

  19. BASIC PRINCIPLES OF THE PYRAMIDS TEMPORAL BONE RADIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Mirko Krstić

    2007-10-01

    Full Text Available This paper shows the possibilities and advantages of certain methods of temporal bone radiography in diagnosing pathological conditions and diseases of temporal bones, with description of basic techniques of radiological examinations: Mayer’s axial view of the pyramids, the Stenvers view of the pyramids, the Arcelini view of the pyramids, comparative pyramid radiography by Hass, comparative pyramid radiography by Gras-hey, comparative pyramid radiography in submentovertical projection and comparative pyramid radiography in verticosubmental projection.

  20. Proton Radiography at Los Alamos

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-28

    The proton radiography (pRad) facility at Los Alamos National Lab uses high energy protons to acquire multiple frame flash radiographic sequences at megahertz speeds: that is, it can make movies of the inside of explosions as they happen. The facility is primarily used to study the damage to and failure of metals subjected to the shock forces of high explosives as well as to study the detonation of the explosives themselves. Applications include improving our understanding of the underlying physical processes that drive the performance of the nuclear weapons in the United States stockpile and developing novel armor technologies in collaboration with the Army Research Lab. The principle and techniques of pRad will be described, and examples of some recent results will be shown.

  1. Neutron radiography in field use

    Energy Technology Data Exchange (ETDEWEB)

    Warman, E. A.

    1962-10-15

    Some of the basic aspects of neutron radiography are reviewed with particular emphasis on the physics of this nondestructive testing method. The results of an experimental evaluation program are presented which show conclusively that isotopic antimony-beryllium photoneutron sources can be used for neutron radiographic applications. This program provided valuable new information regarding neution moderation and beam collimation requirements. Based on this experimental evidence, a portable device was designed and is described. The device employs a portable radiographic camera, with im antimony- beryllium photoneutron source, in conjunction with a neutron moderator and beam collimator configuration. This development makes available, for the first time, a means of obtaining economical inspection neutron radiographs in field application usage. (auth)

  2. Procedimentos de contagem de pontos em um jogo com conteúdo matemático

    Directory of Open Access Journals (Sweden)

    Cláudia Patrocinio Pedroza Canal

    Full Text Available Os alunos apresentam grandes dificuldades na matemática, particularmente no conteúdo dos números inteiros. Diversos trabalhos demonstram como jogos auxiliam na construção de conhecimentos. Assim, esta pesquisa verificou, por meio de um jogo com números inteiros, procedimentos utilizados para realizar as operações de contagem de pontos. Participaram 34 alunos dos 7° e 9° anos do Ensino Fundamental, que jogaram duas rodadas de três partidas contra oponentes de mesma série que a sua. Classificaram-se os dados em a procedimentos de contagem de pontos e b contagem correta e incorreta. Os resultados mostraram associação entre os procedimentos mais simples e o 7° ano e os mais complexos com o 9° ano. Entretanto, os participantes contaram incorretamente os pontos na maioria das partidas. Assim, apesar da associação entre maior nível de escolarização e estratégias mais complexas, estas não determinaram a contagem correta no jogo, demonstrando dificuldade na realização e na compreensão das operações avaliadas.

  3. Procedimento Blupis e seleção massal em cana-de-açúcar

    Directory of Open Access Journals (Sweden)

    Ricardo Augusto de Oliveira

    2011-01-01

    Full Text Available O objetivo deste trabalho foi comparar a seleção via procedimento BLUP individual simulado (BLUPIS versus seleção massal em famílias de irmãos-completos de cana-de-açúcar. Foram utilizadas 80 famílias originadas de cruzamentos biparentais da série RB03. O experimento foi desenvolvido em área experimental, localizado no Município de São Tomé, Paraná. O delineamento experimental foi em blocos incompletos, com cinco repetições por família. Para seleção considerou-se a variável tonelada de sólidos solúveis por hectare (TSH. Utilizou-se o modelo 35 do programa computacional Selegen REML/BLUP, via procedimento BLUPIS para a indicação do número de clones potenciais a serem selecionados. Estes resultados foram correlacionados com o número de clones selecionados via seleção massal dentro das famílias. A seleção clonal via procedimento BLUPIS indica maior número de clones promissores para caracteres quantitativos dentro de famílias com elevados efeitos genotípicos.

  4. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  5. Upgrading of neutron radiography/tomography facility at research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Abd El Bar, Waleed; Mongy, Tarek [Atomic Energy Authority, Cairo (Egypt). ETRR-2; Kardjilov, Nikolay [Helmholtz Zentrum Berlin (HZB) for Materials and Energy, Berlin (Germany)

    2014-03-15

    A state-of-the-art neutron tomography imaging system was set up at the neutron radiography beam tube at the Egypt Second Research Reactor (ETRR-2) and was successfully commissioned in 2013. This study presents a set of tomographic experiments that demonstrate a high quality tomographic image formation. A computer technique for data processing and 3D image reconstruction was used to see inside a copy module of an ancient clay article provided by the International Atomic Energy Agency (IAEA). The technique was also able to uncover tomographic imaging details of a mummified fish and provided a high resolution tomographic image of a defective fire valve. (orig.)

  6. Dose reduction and adequate image quality in digital radiography: a contradiction?; Dosisreduktion und adaequate Bildqualitaet in der digitalen Radiographie: ein Widerspruch

    Energy Technology Data Exchange (ETDEWEB)

    Poetter-Lang, S.; Duenkelmeyer, M. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Uffmann, M. [Krankenhaus Neunkirchen, Abteilung fuer Radiodiagnostik, Neunkirchen (Austria)

    2012-10-15

    Dose reduction and adequate image quality in digital radiography - a contradiction ?Digital radiography has already replaced traditional screen-film systems. Substantial improvements in both dose efficiency and spatial resolution demonstrate the rapid developments in digital radiography. Needle-detector systems have shown up to a 50% dose reduction compared to traditional screen-film systems. There is also a dose reduction capability of up to 50% comparing direct radiography (DR) systems to computed radiography (CR) systems for chest X-rays. However, despite the most recent achievements of CR technology, the dose efficiency of DR systems (caesium iodide flat-panel detector) is unparalleled. The progress in detector technology has contributed to dose reduction and improved image quality, while saving time and providing a higher examination rate. The use of dose indicators and longitudinal dose control are important to avoid substantial accidental dose increase. The dose applied to patients should fall markedly below the defined diagnostic reference levels within the European Union. Regular quality control, as well as continuous education and training of medical and technical personnel, contribute to ensure that the ALARA (as low as reasonably achievable) principle is consistently followed. (orig.) [German] Dosisreduktion und adaequate Bildqualitaet in der digitalen Radiographie - ein Widerspruch ?Die Verfahren der digitalen Radiographie haben die herkoemmlichen Film-Folien-Systeme nahezu vollstaendig ersetzt. Steigende Dosiseffizienz und verbesserte Ortsaufloesung sind die wichtigsten Kenngroessen der rasanten Weiterentwicklung digitaler Detektorsysteme. Bei Nadelkristalldetektoren wurde eine Dosisreduktion bis zu 50% gegenueber Film-Folien-Systemen gefunden. Weiter besteht ein Dosiseinsparungspotenzial von bis zu 50% im Vergleich von Direktradiographie(DR)- mit Computed-radiography(CR)-Systemen bei Thoraxaufnahmen. Trotz der aktuellen Fortschritte bei CR

  7. Errors in digitized lateral cephalometric radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Seon Doo; Cho, Bong Hae; Nah, Kunng Soo [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    1997-08-15

    The purpose of this study is to evaluate the cephalometric reproducibility in digitized cephalometric radiography by comparing the measurement errors between the remeasured and retaken conventional and digitized lateral cephalometric radiography. The mean of the differences and error percentage of each cephalometric measurement were obtained using 96 lateral cephalometric radiography from 48 patients between the age of 11 and 13. The results were as follows; 1. The repeated measurement group of conventional radiography showed least amount of mean differences while those of the retaken measurement group of digitized image showed largest amount of mean differences in every measurement. 2. The measurements which showed statistically significant difference between the conventional radiography and digitized image were S-Go, Ar-Go, S-Ar-Go and S-sN-sNT in repeated measurement group. 3. The measurements which showed statistically significant difference between the repeated and retaken measurement groups were N-S-Ar, MP-L1 and S-sN-sPog in conventional radiography and S-N, Go-Me and N-A in digitized image. 4. Large amount of error percentage was shown at A-N-B and N-A in retaken measurement group of conventional radiography and N-S-Ba and A-N-B in retaken measurement group of digitized image. 5. The amount of error percentage at Ar-Go and N-S-Ar in retaken measurement group of conventional radiography and S-N, N-A, S-N-B and N-S-Ba in retaken measurement group of digitized image was more than double than those from remeasured groups.

  8. Gadolinium sheet converter for neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lima, C.T.S. [Laboratorio de Neutrongrafia em Tempo Real (LNRTR/PEN/COPPE), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil); Crispim, V.R. [Laboratorio de Neutrongrafia em Tempo Real (LNRTR/PEN/COPPE), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil); PEN/COPPE-DNC/Escola Politecnica CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil)], E-mail: verginia@con.ufrj.br; Santos, W.M.S. [Laboratorio de Colisao Atomica e Molecular (LACAM/IF), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68528, 21941-972 Rio de Janeiro, RJ (Brazil)

    2007-12-15

    This work describes a methodology developed for the confection of gadolinium sheet converter for neutron radiography using the gadolinium chloride (GdCl{sub 3}) as material converter. Though manufactured at a relatively low cost, they are as good as the sheet converter on the market. Here, we present neutron radiography of the penetrameter, the edge spread function, the modulation transfer function and characteristic curves for each set sheet-AA400 Kodak film.

  9. Pulmonary mycobacterial disease: diagnostic performance of low-dose digital tomosynthesis as compared with chest radiography.

    Science.gov (United States)

    Kim, Eun Young; Chung, Myung Jin; Lee, Ho Yun; Koh, Won-Jung; Jung, Hye Na; Lee, Kyung Soo

    2010-10-01

    To compare the diagnostic performance of a low-radiation-dose digital tomosynthesis (DTS) technique with that of conventional radiography in the detection of lung lesions in patients with pulmonary mycobacterial disease. The institutional review board approved this study, and all patients provided informed consent. In this study, 100 patients (65 study patients, 35 control patients) underwent multidetector computed tomography (CT), chest radiography, and low-dose DTS (effective doses: 3.4, 0.02, and 0.05 mSv, respectively). Two radiologists evaluated radiographs and DTS images for the presence of parenchymal lesions and the number of cavities in each patient; CT served as the reference standard. Wilcoxon signed rank and McNemar tests and κ statistics were used. The accuracies of DTS and radiography in depicting mycobacterial disease were 97% and 89%, respectively, for observer 1 (P = .039) and 99% and 93%, respectively, for observer 2 (P = .031). The accuracies of DTS and radiography in depicting each lesion type were, respectively, 95% and 77% for bronchiolitis, 92% and 76% for nodules, 86% and 79% for consolidation, and 93% and 70% for cavities. Interobserver agreement with DTS (κ = 0.62-0.94) was superior to that with radiography (κ = 0.46-0.62). Of a total of 141 cavities found with CT, means of 27 (19%) cavities at chest radiography and 108 (77%) cavities at DTS (P performed with a low-dose technique is superior to radiography for the detection of lung lesions in patients with pulmonary mycobacterial disease.

  10. É eticamente aceitavel o uso de recém cadaveres no ensino de procedimentos médicos?

    Directory of Open Access Journals (Sweden)

    José Marques Filho

    Full Text Available A utilização de recém-cadáveres no ensino de procedimentos médicos ocorre com frequência desconhecida. Na área cirúrgica o treinamento de habilidades tem fundamental importância devido à necessidade de procedimentos invasivos próprios dos cirurgiões. Existem raras publicações sobre esse procedimento na área de Bioética, mas é fundamental que esta discussão e reflexão sejam feitas nos departamentos de cirurgia dos hospitais de ensino. A realização de procedimentos em recém-cadáveres deve ser encarada como exceção e ser precedida, obrigatoriamente, de autorização dos familiares.

  11. Image quality and dose management in digital radiography: a new paradigm for optimisation.

    Science.gov (United States)

    Busch, H P; Faulkner, K

    2005-01-01

    The advent of digital imaging in radiology, combined with the explosive growth of technology, has dramatically improved imaging techniques. This has led to the expansion of diagnostic capabilities, both in terms of the number of procedures and their scope. Throughout the world, film/screen radiography systems are being rapidly replaced with digital systems. Many progressive medical institutions have acquired, or are considering the purchase of computed radiography systems with storage phosphor plates or direct digital radiography systems with flat panel detectors. However, unknown to some users, these devices offer a new paradigm of opportunity and challenges. Images can be obtained at a lower dose owing to the higher detective quantum efficiency (DQE). These fundamental differences in comparison to conventional film/screens necessitate the development of new strategies for dose and quality optimizations. A set of referral criteria based upon three dose levels is proposed.

  12. Thorium-uranium fission radiography

    Science.gov (United States)

    Haines, E. L.; Weiss, J. R.; Burnett, D. S.; Woolum, D. S.

    1976-01-01

    Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.

  13. Mobile real time radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Vigil, J.; Taggart, D.; Betts, S. [Los Alamos National Lab., NM (United States)] [and others

    1997-11-01

    A 450-keV Mobile Real Time Radiography (RTR) System was delivered to Los Alamos National Laboratory (LANL) in January 1996. It was purchased to inspect containers of radioactive waste produced at (LANL). Since its delivery it has been used to radiograph more than 600 drums of radioactive waste at various LANL sites. It has the capability of inspecting waste containers of various sizes from <1-gal. buckets up to standard waste boxes (SWB, dimensions 54.5 in. x 71 in. x 37 in.). It has three independent x-ray acquisition formats. The primary system used is a 12- in. image intensifier, the second is a 36-in. linear diode array (LDA) and the last is an open system. It is fully self contained with on board generator, HVAC, and a fire suppression system. It is on a 53-ft long x 8-ft. wide x 14-ft. high trailer that can be moved over any highway requiring only an easily obtainable overweight permit because it weights {approximately}38 tons. It was built to conform to industry standards for a cabinet system which does not require an exclusion zone. The fact that this unit is mobile has allowed us to operate where the waste is stored, rather than having to move the waste to a fixed facility.

  14. Influência do procedimento de mistura em laboratório nas propriedades de argamassas

    Directory of Open Access Journals (Sweden)

    Marylinda Santos de França

    Full Text Available A mistura dos materiais sólidos com a água é uma das etapas mais importantes no preparo das argamassas. A condução do procedimento que é adotado interferirá nas propriedades no estado fresco, assim como no endurecido. A Norma ABNT NBR 13276:2005 indica que os materiais sólidos sejam introduzidos no líquido já disposto no recipiente. Essa ordem de introdução dos materiais é o inverso do que ocorre na prática e pode resultar na falta de homogeneidade da mistura. Estudos anteriores observaram que adicionar o líquido aos materiais sólidos de forma fracionada melhora as propriedades reológicas dos sistemas. Assim, utilizando uma argamassadeira de laboratório e uma mesma formulação, foram estudados distintos procedimentos de mistura em que a água é adicionada no material sólido em etapas. Esses procedimentos foram confrontados com o indicado pela ABNT NBR 13276:2005, e o comportamento reológico (squeeze-flow e ciclos de cisalhamento e as propriedades no estado endurecido (resistência à tração por compressão diametral e módulo de elasticidade dinâmico foram avaliados. Verificou-se que a adição do líquido ao material sólido em etapas distintas conduz a sistemas mais fluidos e com melhor desempenho no estado endurecido.

  15. Noções do procedimento monitório brasileiro para os italianos

    OpenAIRE

    Oliveira Neto, Olavo de; Magistratura do Paraná

    2005-01-01

    Trata de estudo de direito comparado, representado por aula ministrada na Universidade de Estudos de Milão – Itália, traçando uma análise comparativa entre a ação monitória brasileira e o procedimento de injunção italiano. São abordados os aspectos semelhantes e divergentes de ambos sistemas legais, com breve análise daquilo que a doutrina entende no tocante a aplicação dos preceitos. This is a study about comparative jurisprudence, represented for lesson taught in the University of Studie...

  16. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  17. The Delphi technique in radiography education research.

    Science.gov (United States)

    John-Matthews, J St; Wallace, M J; Robinson, L

    2017-09-01

    To describe and review the Delphi technique as a tool for radiographers engaged in mixed-methods research whereby agreement is required on the proficiencies needed by educational programmes for pre- and post- registration radiographers. This is achieved through a description offering a brief history of the technique. Through a literature search, radiography education research using this technique is identified. A protocol for a research project using the technique is presented. Using this worked example, advantages and disadvantages of the method are explored including sampling of participants, sample size, number of rounds and methods of feedback. There are limited examples of the use of the Delphi technique in radiography literature including considerations on how to select experts and panel size. The Delphi technique is a suitable method for establishing collective agreement in the design of radiography educational interventions. Additional research is needed to deepen this evidence-based knowledge. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. Thyroid dose distribution in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bristow, R.G.; Wood, R.E.; Clark, G.M. (Ontario Cancer Institute, Toronto (Canada))

    1989-10-01

    The anatomic position and proven radiosensitivity of the thyroid gland make it an organ of concern in dental radiography. A calibrated thermoluminescent dosimetry system was used to investigate the absorbed dose (microGy) to the thyroid gland resultant from a minimum irradiated volume, intraoral full-mouth radiography technique with the use of rectangular collimation with a lead-backed image receptor, and conventional panoramic radiography performed with front and rear lead aprons. Use of the minimum irradiated volume technique resulted in a significantly decreased absorbed dose over the entire thyroid region ranging from 100% to 350% (p less than 0.05). Because this intraoral technique results in radiographs with greater image quality and also exposes the thyroid gland to less radiation than the panoramic, this technique may be an alternative to the panoramic procedure.

  19. RADIOGRAPHY IN THE FIELD: ASSESSING A LIGHTWEIGHT, HANDHELD, BATTERY-POWERED DENTISTRY UNIT FOR FIELD DIAGNOSTIC APPLICATIONS.

    Science.gov (United States)

    Seilern-Moy, Katharina; Vielgrader, Hanna; Gerritsmann, Hanno; Walzer, Chris

    2017-03-01

    Radiography units are not used commonly in wildlife medicine field settings, primarily because of their weight and requirement for a power supply. In this study, a portable, battery-powered, and lightweight radiography unit, originally developed for dentistry, was assessed for its potential field applications. Radiographs of various animal species (ranging in weight from 14 g to 1,000 kg) were imaged using varying source image distance (SID) and exposure time. The quality of these images was evaluated for their resolution, image noise, and motion blur. When required, image resolutions were further enhanced using computed radiography postprocessing. Other parameters evaluated were the freehand use of the device, its battery durability, the maximum obtainable image size, and multiple use of a single computed radiography cassette. Using an SID of 60 cm, radiographs delivered adequate image quality. The quality, however, was found deteriorated in images of larger animals (>50 kg) or thicker tissues (>15 cm). The use of a tripod proved unnecessary in most cases, and its exclusion greatly facilitated equipment handling. Under field conditions, the battery was depleted after a total running time of 1.6 hr or 36 radiographs. The maximum size of a radiographic image reached a diameter of 40 cm, and radiation shielding allowed the multiple use of a single computed radiography cassette. Taken together, the radiography unit evaluated in this study presented a balanced compromise between portability and radiograph quality for field use. However, the unit image resolution cannot replace those of the fixed standard radiography units commonly used in veterinary medicine.

  20. Charter of good practices in industrial radiography; Charte de bonnes pratiques en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  1. 10 CFR 34.13 - Specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Specific license for industrial radiography. 34.13 Section 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... industrial radiography. An application for a specific license for the use of licensed material in industrial...

  2. The frequency of various indications for plain chest radiography in ...

    African Journals Online (AJOL)

    2012-05-20

    May 20, 2012 ... Conclusion: The most frequent indications for chest radiography in the study are certain infection and parasitic diseases. Chest Radiography is the most frequent ... Chest radiography will include views of the lungs, heart small portions of .... Endocrine, Nutrition and Metabolic diseases. 22. 1.5. 1.5. 97.2.

  3. Digital panoramic radiography: a clinical survey

    Energy Technology Data Exchange (ETDEWEB)

    Nessi, R. [Inst. of Radiological Sciences, Univ. of Milan, S. Paolo Hospital (Italy); Minorati, D. [Inst. of Radiological Sciences, Univ. of Milan, S. Paolo Hospital (Italy); Dova, S. [Inst. of Radiological Sciences, Univ. of Milan, S. Paolo Hospital (Italy); Blanc, M. [Inst. of Radiological Sciences, Univ. of Milan, S. Paolo Hospital (Italy)

    1995-12-31

    The application of digital panoramic radiography with photostimulable phosphors to dental diagnosis was evaluated in 500 patients. Comparative intraoral films of selected groups of teeth and electronic magnifications of the same portion of the arches were obtained in 63 cases. Digital images improved the quality of dental examinations compared with film radiographs. The possibility of contrast modulation was helpful to compensate for the different radiographic densities of the arches and to improve the visibility of gingival soft tissues. In addition, digital radiography reduced the radiation dose administered to the patient. (orig.)

  4. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young [Dept. of Nuclear Engineering, Kyung Hee University, Yongin (Korea, Republic of)

    2016-11-15

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety.

  5. Screening of illegal intracorporeal containers ("body packing"): is abdominal radiography sufficiently accurate? A comparative study with low-dose CT.

    Science.gov (United States)

    Poletti, Pierre-Alexandre; Canel, Laurent; Becker, Christoph D; Wolff, Hans; Elger, Bernice; Lock, Eric; Sarasin, François; Bonfanti, Monica S; Dupuis-Lozeron, Elise; Perneger, Thomas; Platon, Alexandra

    2012-12-01

    To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography. © RSNA, 2012.

  6. Felipressina aumenta pressão arterial durante procedimento odontológico em pacientes hipertensos

    Directory of Open Access Journals (Sweden)

    Ana Lúcia Aparecida Bronzo

    2012-08-01

    Full Text Available FUNDAMENTO: A felipressina foi adicionada ao anestésico local para aumentar a duração do efeito anestésico e reduzir a toxicidade nos procedimentos dentários. No entanto, o efeito sobre a pressão arterial é incerta, e isso pode ser altamente relevante no tratamento dentário de pacientes hipertensos. OBJETIVO: Investigar o efeito da felipressina sobre a pressão arterial em pacientes hipertensos com pressão arterial controlada. MÉTODOS: Foram estudados 71 indivíduos com essas características e com necessidade de tratamento periodontal. Após 10 minutos de repouso, a anestesia local (prilocaína foi infiltrada com e sem adição de felipressina. Em seguida, uma raspagem subgengival profunda foi realizada. A pressão arterial foi medida por um equipamento oscilométrico automático (DIXTAL DX2010. Dez minutos após a administração do anestésico, o pico de ação anestésica foi gravado. O Inventário de Ansiedade Traço-Estado (IDATE foi utilizado para avaliar o traço de ansiedade nos pacientes. RESULTADOS: A pressão arterial sistólica aumentou após a anestesia, independentemente da associação com felipressina, durante todo o procedimento dentário (p < 0,05, e essa resposta pode ser explicada, pelo menos em parte, pelos níveis de traço de ansiedade dos indivíduos. No entanto, um aumento adicional na pressão arterial diastólica foi observado quando a prilocaína foi associada a felipressina (p < 0,05, mas essa resposta não se alterou com os níveis de traço de ansiedade. CONCLUSÃO: A felipressina aumentou a pressão arterial diastólica de pacientes hipertensos com pressão arterial controlada. Pacientes com traço de ansiedade elevado apresentaram aumento na pressão arterial sistólica em alguns procedimentos, sugerindo que um aumento da pressão arterial também pode estar relacionado ao medo ou à ansiedade.

  7. Stenosis of calcified carotid artery detected on Panoramic Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, So Yang; Oh, Won Mann; Yoon, Suk Ja; Yoon, Woong; Lee, Jae Seo; Kang, Byung Cheol [School of Dentistry, Chonnam National University, Seoul (Korea, Republic of); Palomo, Juan M. [Department of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland (United States)

    2009-09-15

    This study aimed to investigate the luminal stenosis of the internal carotid artery with calcification detected on panoramic radiographs. This study used fifty carotid arteries of 36 dental patients whose panoramic radiograph and computed tomography angiography (CTA) revealed the presence of carotid artery calcification. A neuroradiologist interpreted CTA to determine the degree of stenosis of the internal carotid arteries. The degree of stenosis was stratified in four stages; normal (no stenosis), mild stenosis (1-49%), moderate stenosis (50-69%) and severe stenosis (70-99%). Among the fifty carotid arteries with calcification detected on both panoramic radiography and CTA, 20 carotid arteries (40%) were normal, 29 carotid arteries (18%) had mild stenosis, 1 carotid artery (2%) had moderate stenosis, and there was none with severe stenosis. Sixty percent of the carotid arteries with calcification detected on both panoramic radiography and CTA had internal luminal stenosis, and two percent had moderate stenosis. When carotid atheroma is detected on panoramic radiograph, it is possible that the dental patient has luminal stenosis of the internal carotid artery.

  8. Absorbed dose in the full-mouth periapical radiography, panoramic radiography, and zonography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soon Chul; Choi, Hang Moon [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1999-02-15

    The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ, parotid gland, bone marrow in the mandibular body, and thyroid gland during the full-mouth periapical radiography, panoramic radiography, and zonography were measured. From the zonography, the absorbed doses to the brain, the skin over the TMJ, and the parotid gland were relatively high, but the absorbed doses to the bone marrow in the mandibular body and, especially, the thyroid gland were very low. The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  9. Entrevistar e Escrever: procedimentos para palavras encarnadas de dança

    Directory of Open Access Journals (Sweden)

    Cássia Navas Alves de Castro

    2015-09-01

    Full Text Available A partir de estudos de caso de uma longa trajetória em pesquisa, articulam-se exemplos, descrições, propostas e discussões sobre a investigação em dança, com foco em dois aspectos – a entrevista e a escrita. Aponta-se para procedimentos do inquirir-se – como a pergunta-stick – e formatos de sua escritura – como a entre-escritura –, visando à ampliação do debate sobre métodos, processos e sistemas metodológicos nas artes da cena contemporânea como contribuição para a discussão sobre caminhos metodológicos oriundos desse mesmo campo do conhecimento.

  10. ASSISTÊNCIA DE ENFERMAGEM AO PREMATURO: ALGUNS PROCEDIMENTOS BÁSICOS

    Directory of Open Access Journals (Sweden)

    Miriam Aparecida Barbosa Merighi

    Full Text Available São apresentados os procedimentos básicos de assistência de enfermagem ao prematuro, a saber: observação nas primeiras 24 horas de vida, hidratação, alimentação com mamadeira, alimentação por sonda nasogástrica, cuidados após a alimentação, técnica do banho na incubadora, cuidado com a pele, cuidado com o coto umbilical, cuidado do prematuro com monilíase, diarréia, vômito, problemas respiratórios, cuidado do prematuro em oxigenoterapia, limpeza e conservação da incubadora.

  11. Feline dental radiography and radiology: A primer.

    Science.gov (United States)

    Niemiec, Brook A

    2014-11-01

    Information crucial to the diagnosis and treatment of feline oral diseases can be ascertained using dental radiography and the inclusion of this technology has been shown to be the best way to improve a dental practice. Becoming familar with the techniques required for dental radiology and radiography can, therefore, be greatly beneficial. Novices to dental radiography may need some time to adjust and become comfortable with the techniques. If using dental radiographic film, the generally recommended 'E' or 'F' speeds may be frustrating at first, due to their more specific exposure and image development requirements. Although interpreting dental radiographs is similar to interpreting a standard bony radiograph, there are pathologic states that are unique to the oral cavity and several normal anatomic structures that may mimic pathologic changes. Determining which teeth have been imaged also requires a firm knowledge of oral anatomy as well as the architecture of dental films/digital systems. This article draws on a range of dental radiography and radiology resources, and the benefit of the author's own experience, to review the basics of taking and interpreting intraoral dental radiographs. A simplified method for positioning the tubehead is explained and classic examples of some common oral pathologies are provided. © ISFM and AAFP 2014.

  12. INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTORS' GUIDE. VOLUME 2.

    Science.gov (United States)

    Texas A and M Univ., College Station. Engineering Extension Service.

    INFORMATION RELATIVE TO THE LESSON PLANS IN "INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTOR'S GUIDE, VOLUME I" (VT 003 565) IS PRESENTED ON 52 INFORMATION SHEETS INCLUDING THE SUBJECTS SHIELDING EQUATIONS AND LOGARITHMS, METAL PROPERTIES, FIELD TRIP INSTRUCTIONS FOR STUDENTS, WELDING SYMBOLS AND SIZES, SAMPLE REPORT FORMS, AND TYPICAL SHIPPING…

  13. OPINION PIECE Rethinking responsibility in radiography: Some ...

    African Journals Online (AJOL)

    OPINION PIECE. Introduction. The field of radiography in South Africa is complex and presents a multitude of ethical issues. The discipline is often regarded as a supporting function in the healthcare chain, and a stepping-stone in the diagnostic process. This status of the discipline seems to have left many radiographers in ...

  14. Establishing rigour in qualitative radiography research

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, F.J. [School of Healthcare Professions, University of Salford, Salford M6 6PU (United Kingdom)], E-mail: f.j.murphy@salford.ac.uk; Yielder, J. [Medical Imaging, School of Health Sciences, Unitec, Auckland (New Zealand)

    2010-02-15

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  15. Radiography Following Perinatal Death: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, Oe.E. [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom). Radiology Dept.

    2006-02-15

    Radiography of the perinatally dead infant provides detailed information about the skeleton and is valuable as an adjunct to autopsy. This article reviews the potential benefits and discusses the pitfalls in assessment of growth stage. Reference charts for individual bone lengths and secondary ossification centers are presented.

  16. Radiography Student Participation in Professional Organizations.

    Science.gov (United States)

    Michael, Kimberly; Tran, Xuan; Keller, Shelby; Sayles, Harlan; Custer, Tanya

    2017-09-01

    To gather data on educational program requirements for student membership in a state or national professional society, organization, or association. A 10-question online survey about student involvement in professional societies was emailed to 616 directors of Joint Review Committee on Education in Radiologic Technology (JRCERT)-accredited radiography programs. A total of 219 responses were received, for a 36% response rate. Of these, 89 respondents (41%) answered that their programs require students to join a professional organization. The society respondents most often required (70%) was a state radiography society. Sixty respondents (68%) answered that students join a society at the beginning of the radiography program (from matriculation to 3 months in). Of programs requiring student membership in professional societies, 42 (49%) reported that their students attend the state or national society annual conference; however, participation in activities at the conferences and in the society throughout the year is lower than conference attendance. Some directors stated that although their programs' policies do not allow membership mandates, they encourage students to become members, primarily so that they can access webinars and other educational materials or information related to the profession. Survey data showed that most JRCERT-accredited radiography programs support but do not require student membership in professional organizations. The data reveal that more programs have added those requirements in recent years. Increased student participation could be realized if programs mandated membership and supported it financially. ©2017 American Society of Radiologic Technologists.

  17. Conditions for radiation protection in industrial radiography

    CERN Document Server

    1999-01-01

    The leaflet specifies radiation protection requirements for industrial radiography in Norway. The regulations are directed towards companies using or distributing sealed radioactive sources, x-ray equipment or accelerators in non-destructive material testing (NDT). Technical requirements to the equipment, as well as administrative requirements for use, licensing, qualifications, handling of accidents etc. are given. (Author)

  18. Procedimento intraparto extra-uterino (EXIT num caso de linfangiona cervical

    Directory of Open Access Journals (Sweden)

    Fátima Ribeiro

    2016-02-01

    Full Text Available Introdução: Fetos com diagnóstico pré-natal de malformações anatómicas envolvendo a face e/ou o pescoço estão em risco de obstrução das vias aéreas desde o pós-natal imediato. A programação de medidas periparto que previnam a compressão das vias aéreas, mantendo uma adequada circulação fetal, é fundamental no prognóstico. Caso Clínico: Feto com diagnóstico ecográfico, às 31 semanas de gestação, de volumosa massa cervical e facial, compatível com linfangioma quístico. O caso foi discutido em equipa multidisciplinar, tendo sido decidida a realização de cesariana associada ao procedimento EXIT às 39 semanas de gestação. Após exteriorização do polo cefálico, foi confirmada massa cervical e facial direita, sendo o feto sujeito a intubação oro-traqueal no primeiro minuto. Ao sexto dia de vida foi submetido a cirurgia, com excisão parcial da massa. Conclusão: O procedimento EXIT permite a manutenção de uma adequada oxigenação fetal enquanto se estabelece uma via aérea patente. Uma adequada coordenação da equipa multi-disciplinar é fundamental para o êxito da técnica.

  19. A survey of sub-specialty preferences of radiography students of the University of Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    E T Namah

    2013-01-01

    Full Text Available Background: Technological advances and computing have expanded both the scope and capacity of diagnostic medical imaging (the radiography profession. This has created many diverse imaging modalities which in turn, have culminated in different sub-specialties in the profession. Objective: The aims of the study were to determine the level of awareness of imaging sub-specialties, preferred sub specialties and reasons for preferences of sub-specialties in senior level radiography students of the University of Lagos. Methods: The study was a prospective cross-sectional survey. Consents were obtained before the students were recruited for the study. Data Collection and Analysis: A questionnaire semi-structured in line with objectives of the study was used in data collection. A computer software Epi Info version 3.3 was used to analyze data while results were expressed as percentages of responses and were presented in tables and pie charts. Results : Greater than 90% showed awareness of sub-specialties in the radiography profession whereas 35% preferred ultrasonography to other sub-specialties. The least preferred sub-specialty was conventional radiography (4.3%. Remuneration (73.3% and less physical exertion (73.3% were major attractors to preferred sub-specialties whereas concerns over radiation hazard were major detractors (58.3%. Conclusion : Awareness of sub-specialties in the radiography profession was high amongst students studied. Furthermore, ultrasonography was the most preferred sub-specialty among the respondents. Remuneration was the main attractor to sub-specialties whereas fears over effects of ionizing radiation were the major detractors to some sub-specialties.

  20. Cumulative radiation exposure and associated cancer risk estimates for scoliosis patients: Impact of repetitive full spine radiography.

    Science.gov (United States)

    Law, Martin; Ma, Wang-Kei; Lau, Damian; Chan, Eva; Yip, Lawrance; Lam, Wendy

    2016-03-01

    To quantitatively evaluate the cumulative effective dose and associated cancer risk for scoliotic patients undergoing repetitive full spine radiography during their diagnosis and follow up periods. Organ absorbed doses of full spine exposed scoliotic patients at different age were computer simulated with the use of PCXMC software. Gender specific effective dose was then calculated with the ICRP-103 approach. Values of lifetime attributable cancer risk for patients exposed at different age were calculated for both patient genders and for Asian and Western population. Mathematical fitting for effective dose and for lifetime attributable cancer risk, as function of exposed age, was analytically obtained to quantitatively estimate patient cumulated effective dose and cancer risk. The cumulative effective dose of full spine radiography with posteroanterior and lateral projection for patients exposed annually at age between 5 and 30 years using digital radiography system was calculated as 15mSv. The corresponding cumulative lifetime attributable cancer risk for Asian and Western population was calculated as 0.08-0.17%. Female scoliotic patients would be at a statistically significant higher cumulated cancer risk than male patients under the same full spine radiography protocol. We demonstrate the use of computer simulation and analytic formula to quantitatively obtain the cumulated effective dose and cancer risk at any age of exposure, both of which are valuable information to medical personnel and patients' parents concern about radiation safety in repetitive full spine radiography. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Human body radiography simulations: development of a virtual radiography environment

    Science.gov (United States)

    Inanc, F.; Gray, Joseph N.; Jensen, Terrence; Xu, J.

    1998-07-01

    A simulation program for x-ray methods is discussed. Computational algorithms for definition of x-ray sources, interactions of x-rays with complex objects and formation of images are developed from first principles. Subject geometries can be accessed from CAD definitions or from CT sets. The principles underlying the image formation process are introduced and images in industrial and medical x-ray applications are displayed.

  2. Measuring the Quadriceps Angle by a New Method and Comparison with Goniometer and Radiography

    Directory of Open Access Journals (Sweden)

    Yahya Sokhangouei

    2012-07-01

    Full Text Available Objective: The purpose of this study is to decrease the amount of error when measuring Q–angles using a goniometer by the new method, a private system developed at the I.R's university of social welfare & rehabilitation sciences (USWR by Investigator. Materials & Methods: Fourty subjects with Eighty healthy knees participated in this methodologic study. One investigator participated in data collection who is a licensed physical therapist and has over 6 years of clinical experience in orthopedic physical therapy. He has designed and experienced with new method and computer program. Quadriceps angles measured bilaterally for 40 subjects were recorded. Reliability and validity with new method of the measurements were calculated with Intraclass Correlation Coefficient (ICC & Repeated Measurement for new method and compared it's result with goniometry in contrast with radiography. Results: The ICC for measuring Q-angle with a new method versus the radiography was 0.935, while the ICC for measuring Q-angle with the goniometry versus the radiography was 0.696. The ICC between measures three times obtained with a New Method was 0.974. Conclusion: There is a high association between measures of Q-angle obtained with a new method compared to those obtained with radiography while this association for goniometry is low. Intratester reliability for new method is good and this method can applied as a good measurement method of Q angle.

  3. Quantitative shadowgraphy and proton radiography for large intensity modulations

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ratan, Naren; Sadler, James; Chen, Nicholas; Savert, Alexander; Trines, Raoul; Bingham, Robert; Burrows, Philip N; Kaluza, Malte C; Norreys, Peter

    2016-01-01

    Shadowgraphy is a technique widely used to diagnose objects or systems in various fields in physics and engineering. In shadowgraphy, an optical beam is deflected by the object and then the intensity modulation is captured on a screen placed some distance away. However, retrieving quantitative information from the shadowgrams themselves is a challenging task because of the non-linear nature of the process. Here, a novel method to retrieve quantitative information from shadowgrams, based on computational geometry, is presented for the first time. This process can be applied to proton radiography for electric and magnetic field diagnosis in high-energy-density plasmas and has been benchmarked using a toroidal magnetic field as the object, among others. It is shown that the method can accurately retrieve quantitative parameters with error bars less than 10%, even when caustics are present. The method is also shown to be robust enough to process real experimental results with simple pre- and post-processing techn...

  4. Segurança do cliente e as ações frente ao procedimento cirúrgico

    Directory of Open Access Journals (Sweden)

    Andréia Regina Lopes Grigoleto

    2011-06-01

    Full Text Available O procedimento anestésico-cirúrgico é parte integrante da assistência à saúde, contribuindo na prevenção de agravos à integridade física e perda de vidas. Como estratégia na redução desses eventos a Organização Mundial da Saúde lançou a campanha “cirurgias seguras salvam vidas”. Com o objetivo de discutir as ações voltadas à segurança dos pacientes no período operatório, buscou-se no site da Organização Mundial da Saúde os estudos disponíveis sobre avanços na execução de procedimentos seguros, com a implementação do Checklist, na sistematização dos cuidados preconizados no centro cirúrgico, que garantam alta eficácia e baixo custo. O estudo explicita e discorre sobre a estratégia de utilização do Sistema “Checklist”, apresentando ações específicas que permeiam três momentos do procedimento anestésico-cirúrgico. A implementação do Checklist confere o alcance do procedimento correto, pela equipe correta e paciente correto, tendo em vista estabelecer processos seguros na realização da cirurgia.

  5. SisRadiologia: a new software tool for analysis of radiological accidents and incidents in industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da, E-mail: araujocamila@yahoo.com.br, E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Araujo, Rilton A., E-mail: consultoria@maximindustrial.com.br [Maxim Industrial Assessoria TI, Rio de Janeiro, RJ (Brazil)

    2013-07-01

    According to the International Atomic Energy Agency (IAEA), many efforts have been made by Member states, aiming a better control of radioactive sources. Accidents mostly happened in practices named as high radiological risk and classified by IAEA in categories 1 and 2, being highlighted those related to radiotherapy, large irradiators and industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography area, involving 37 workers, 110 members of the public and 12 fatalities. Records display 5 severe radiological accidents in industrial radiography activities in Brazil, in which 7 workers and 19 members of the public were involved. Such events led to hands and fingers radiodermatitis, but to no death occurrence. The purpose of this study is to present a computational program that allows the data acquisition and recording in the company, in such a way to ease a further detailed analysis of radiological event, besides providing the learning cornerstones aiming the avoidance of future occurrences. After one year of the 'Industrial SisRadiologia' computational program application - and mostly based upon the workshop about Analysis and Dose Calculation of Radiological Accidents in Industrial Radiography (Workshop sobre Analise e Calculo de dose de acidentes Radiologicos em Radiografia Industrial - IRD 2012), in which several Radiation Protection officers took part - it can be concluded that the computational program is a powerful tool to data acquisition, as well as, to accidents and incidents events recording and surveying in Industrial Radiography. The program proved to be efficient in the report elaboration to the Brazilian Regulatory Authority, and very useful in workers training to fix the lessons learned from radiological events.

  6. Artifacts found during quality assurance testing of computed radiography and digital radiography detectors

    National Research Council Canada - National Science Library

    Honey, Ian D; Mackenzie, Alistair

    2009-01-01

    ...) and integrated digital radiographic X-ray imaging detectors are presented. The images presented are all either flat field or test object images and show artifacts previously either undescribed in the existing literature or meriting further comment...

  7. Conversion from Film to Image Plates for Transfer Method Neutron Radiography of Nuclear Fuel

    Science.gov (United States)

    Craft, Aaron E.; Papaioannou, Glen C.; Chichester, David L.; Williams, Walter J.

    This paper summarizes efforts to characterize and qualify a computed radiography (CR) system for neutron radiography of irradiated nuclear fuel at Idaho National Laboratory (INL). INL has multiple programs that are actively developing, testing, and evaluating new nuclear fuels. Irradiated fuel experiments are subjected to a number of sequential post-irradiation examination techniques that provide insight into the overall behavior and performance of the fuel. One of the first and most important of these exams is neutron radiography, which provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Results from neutron radiography are often the driver for subsequent examinations of the PIE program. Features of interest that can be evaluated using neutron radiography include irradiation-induced swelling, isotopic and fuel-fragment redistribution, plate deformations, and fuel fracturing. The NRAD currently uses the foil-film transfer technique with film for imaging fuel. INL is pursuing multiple efforts to advance its neutron imaging capabilities for evaluating irradiated fuel and other applications, including conversion from film to CR image plates. Neutron CR is the current state-of-the-art for neutron imaging of highly-radioactive objects. Initial neutron radiographs of various types of nuclear fuel indicate that radiographs can be obtained of comparable image quality currently obtained using film. This paper provides neutron radiographs of representative irradiated fuel pins along with neutron radiographs of standards that informed the qualification of the neutron CR system for routine use. Additionally, this paper includes evaluations of some of the CR scanner parameters and their effects on image quality.

  8. The evaluation the magnitude radiation exposure dose rate in digital radiography room design

    Science.gov (United States)

    Dwiyanto, Agung; Setia Budi, Wahyu; Hardiman, Gagoek

    2017-12-01

    This study discusses the dose rate in digital radiography room, buit according to meet the provisions of KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation of BAPETEN No. 8 / 2011. The provisions primary concern of radiation safety, not comfort, by considering the space design. There are five aspects to consider in designing the space: functionality, comfort, security, movement activities and aesthetics. However provisions only met three aspects of the design, which are a function, security and movement activity. Therefore, it is necessary to evaluate digital radiography room in terms of its ability to control external radiation exposure to be safe and comfortable The dose rate is measured by the range of primary and secondary radiation in the observation points by using Surveymeter. All data are obtained by the preliminary survey prior to the study. Furthermore, the review of digital radiography room is done based on architectural design theory. The dose rate for recommended improvement room is recalculated using the same method as the actual room with the help of computer modeling. The result of dose rate calculation at the inner and outer part of digital radiography observation room shows that in-room dose for a week at each measuring point exceeds the allowable dose limit both for staff and public. During a week of observation, the outdoor dose at some measuring points exceeds the dose limit set by the KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation BEPETEN No 8/2011. Meanwhile, the result of dose rate calculation in the inner and outer part of the improved digital radiography room can meet the applicable regulations better.

  9. Comparison of the accuracy of digital and conventional radiography in evaluation of curved canals lengths.

    Directory of Open Access Journals (Sweden)

    Ezoddini Ardakani F.

    2005-07-01

    Full Text Available Background and Aim: Proper shaping and cleaning of the root canal system is one of the most important aspects of endodontic treatment. To estimate the canal length before instrumentation in endodontic treatment, traditionally, conventional radiographic techniques and recently Direct Digital Radiography (DDR are applied. The application of computer technology to radiography has allowed less exposure time, image acquisition, manipulation, storage, retrieval, and transmission to remote sites in a digital format, elimination of wet processing and considerable reduction in the time lapse between image acquisition and display. The purpose of this study was to compare the accuracy of DDR versus conventional radiography in estimating endodontic file lengths of curved canals in first mandibular molars. Materials and Methods: In this test evaluation study, fourty extracted human first mandibular molars with root curvature were selected. Samples were divided into two groups: With root curvature less than 25 and more than 25. Samples were mounted in plaster blocks and canal lengths were estimated by using DDR and conventional radiographs. Regression analysis and correlation coefficient were used to calculate statistical differences between the groups with P<0.05 as the limit of significance. Results: Conventional radiography was more precise in canals with less than 25 degrees curvature (P=0.160. While, DDR was more precise for canals with curvature more than 25 degrees (P=0.605. However, these differences were not statistically significant. Conclusion: The image quality of DDR system has improved to the point that it can now be used for estimating canal lengths, even for curved canals, with accuracy comparable to that of conventional radiography.

  10. Conversion from film to image plates for transfer method neutron radiography of nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Craft, Aaron E.; Papaioannou, Glen C.; Chichester, David L.; Williams, Walter J.

    2017-02-01

    This paper summarizes efforts to characterize and qualify a computed radiography (CR) system for neutron radiography of irradiated nuclear fuel at Idaho National Laboratory (INL). INL has multiple programs that are actively developing, testing, and evaluating new nuclear fuels. Irradiated fuel experiments are subjected to a number of sequential post-irradiation examination techniques that provide insight into the overall behavior and performance of the fuel. One of the first and most important of these exams is neutron radiography, which provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Results from neutron radiography are often the driver for subsequent examinations of the PIE program. Features of interest that can be evaluated using neutron radiography include irradiation-induced swelling, isotopic and fuel-fragment redistribution, plate deformations, and fuel fracturing. The NRAD currently uses the foil-film transfer technique with film for imaging fuel. INL is pursuing multiple efforts to advance its neutron imaging capabilities for evaluating irradiated fuel and other applications, including conversion from film to CR image plates. Neutron CR is the current state-of-the-art for neutron imaging of highly-radioactive objects. Initial neutron radiographs of various types of nuclear fuel indicate that radiographs can be obtained of comparable image quality currently obtained using film. This paper provides neutron radiographs of representative irradiated fuel pins along with neutron radiographs of standards that informed the qualification of the neutron CR system for routine use. Additionally, this paper includes evaluations of some of the CR scanner parameters and their effects on image quality.

  11. Registration of pencil beam proton radiography data with X-ray CT.

    Science.gov (United States)

    Deffet, Sylvain; Macq, Benoît; Righetto, Roberto; Vander Stappen, François; Farace, Paolo

    2017-10-01

    Proton radiography seems to be a promising tool for assessing the quality of the stopping power computation in proton therapy. However, range error maps obtained on the basis of proton radiographs are very sensitive to small misalignment between the planning CT and the proton radiography acquisitions. In order to be able to mitigate misalignment in postprocessing, the authors implemented a fast method for registration between pencil proton radiography data obtained with a multilayer ionization chamber (MLIC) and an X-ray CT acquired on a head phantom. The registration was performed by optimizing a cost function which performs a comparison between the acquired data and simulated integral depth-dose curves. Two methodologies were considered, one based on dual orthogonal projections and the other one on a single projection. For each methodology, the robustness of the registration algorithm with respect to three confounding factors (measurement noise, CT calibration errors, and spot spacing) was investigated by testing the accuracy of the method through simulations based on a CT scan of a head phantom. The present registration method showed robust convergence towards the optimal solution. For the level of measurement noise and the uncertainty in the stopping power computation expected in proton radiography using a MLIC, the accuracy appeared to be better than 0.3° for angles and 0.3 mm for translations by use of the appropriate cost function. The spot spacing analysis showed that a spacing larger than the 5 mm used by other authors for the investigation of a MLIC for proton radiography led to results with absolute accuracy better than 0.3° for angles and 1 mm for translations when orthogonal proton radiographs were fed into the algorithm. In the case of a single projection, 6 mm was the largest spot spacing presenting an acceptable registration accuracy. For registration of proton radiography data with X-ray CT, the use of a direct ray-tracing algorithm to compute

  12. [Lateral radiography of the knee with single-leg standing].

    Science.gov (United States)

    Ohmori, Kan; Sugawara, Tsuyoshi; Murakami, Katsuyoshi; Kirinai, Mikio; Fujiwara, Junichi; Oikawa, Takumi; Matsumura, Yutaka; Sugawara, Tsukasa

    2002-07-01

    The purpose of this investigation was to accomplish reproducible radiography of single-leg standing lateral radiography of the knee by adjusting lateral rotation using a ruler to measure foot position. After preliminary assessment of three-dimensional CT of the knees of normal volunteers, the best adjustment of external rotation was estimated. A ruler was made for use in adjusting the angle of knee rotation by measuring foot rotation. Based on the foot rotation measured by this ruler, the positioning of radiography was adjusted to correct rotation. Rotation was estimated by the distance between the posterior edges of the lateral and medial femoral condyles. Fifteen-degree and 17.5-degree rotations were used for correction. Correction of rotation was 17 degrees on average. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate of lateral knee radiography.

  13. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  14. Bloqueio do nervo supraescapular: procedimento importante na prática clínica

    Directory of Open Access Journals (Sweden)

    Marcos Rassi Fernandes

    2012-02-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A dor no ombro é uma queixa frequente que ocasiona grande incapacidade funcional no membro acometido, assim como redução na qualidade de vida dos pacientes. O bloqueio do nervo supraescapular é um método terapêutico eficaz e vem sendo cada vez mais utilizado pelos anestesiologistas tanto para anestesia regional quanto para analgesia pós-operatória de cirurgias realizadas nesta articulação, o que justifica a presente revisão, cujo objetivo principal é descrever a técnica aplicada e as indicações clínicas. CONTEÚDO: Apresenta-se a anatomia do nervo supraescapular, desde a sua origem do plexo braquial até os seus ramos terminais, assim como as características gerais e a técnica empregada na execução do bloqueio deste nervo, as principais drogas utilizadas e o volume e as situações em que se faz jus a sua aplicação. CONCLUSÕES: O bloqueio do nervo supraescapular é um procedimento seguro e extremamente eficaz na terapia da dor no ombro. Também de fácil reprodutibilidade, está sendo muito utilizado por profissionais de várias especialidades médicas. Quando bem indicado, este método deve ser considerado

  15. Estimativa dos valores de MSAD em procedimentos de tomografia computadorizada utilizando filmes radiocrômicos

    Directory of Open Access Journals (Sweden)

    Bruno Beraldo Oliveira

    2013-04-01

    Full Text Available OBJETIVO: Verificar a viabilidade de filmes radiocrômicos como um dosímetro alternativo para estimativa da dose média em cortes múltiplos a partir dos perfis de kerma. MATERIAIS E MÉTODOS: Os filmes foram distribuídos em cilindros posicionados no centro e nas regiões periféricas de um objeto simulador padrão de abdome utilizado para dosimetria em tomografia computadorizada. RESULTADOS: Os valores de dose média em cortes múltiplos calculados foram 13,6 ± 0,7, 13,5 ± 0,7 e 18,7 ± 1,0 mGy para os valores de passo (pitch de 0,75, 1,00 e 1,50, respectivamente. CONCLUSÃO: Apesar de os resultados mostrarem valores menores que o nível de referência de radiodiagnóstico de 25 mGy estabelecido pela legislação brasileira para exames de abdome, eles sugerem que há espaço para otimização dos procedimentos e uma revisão do valor para o nível de referência de radiodiagnóstico brasileiro.

  16. Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research

    Energy Technology Data Exchange (ETDEWEB)

    Lim, I. C.; Seo, C. G.; Jeong, J. H.; Lee, B. H.; Choi, Y. S

    2001-01-01

    For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.

  17. Modeling and measurement of root canal using stereo digital radiography

    Science.gov (United States)

    Analoui, Mostafa; Krisnamurthy, Satthya; Brown, Cecil

    2000-04-01

    Determining root canal length is a crucial step in success of root canal treatment. Root canal length is commonly estimated based on pre-operation intraoral radiography. 2D depiction of a 3D object is the primary source of error in this approach. Techniques based on impedance measurement are more accurate than radiographic approaches, but do not offer a method for depicting the shape of canal. In this study, we investigated a stererotactic approach for modeling and measurement of root canal of human dentition. A weakly perspective model approximated the projectional geometry. A series of computer-simulated objects was used to test accuracy of this model as the first step. The, to assess the clinical viability of such an approach, endodontic files inserted in the root canal phantoms were fixed on an adjustable platform between a radiographic cone and an image receptor. Parameters of projection matrix were computed based on the relative positions of image receptors, focal spot, and test objects. Rotating the specimen platform from 0 to 980 degrees at 5-degree intervals set relative angulations for stereo images. Root canal is defined as the intersection of two surfaces defined by each projection. Computation of error for length measurement indicates that for angulations greater than 40 degrees the error is within clinically acceptable ranges.

  18. EOS imaging versus current radiography: A health technology assessment study.

    Science.gov (United States)

    Mahboub-Ahari, Alireza; Hajebrahimi, Sakineh; Yusefi, Mahmoud; Velayati, Ashraf

    2016-01-01

    EOS is a 2D/3D muscle skeletal diagnostic imaging system. The device has been developed to produce a high quality 2D, full body radiographs in standing, sitting and squatting positions. Three dimensional images can be reconstructed via sterEOS software. This Health Technology Assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged EOS imaging system in comparison with conventional x-ray radiographic techniques. All cost and outcome data were assessed from Iran's Ministry of Health Perspective. Data for clinical effectiveness was extracted using a rigorous systematic review. As clinical outcomes the rate of x-ray emission and related quality of life were compared with Computed Radiography (CR) and Digital Radiography (DR). Standard costing method was conducted to find related direct medical costs. In order to examine robustness of the calculated Incremental Cost Effectiveness Ratios (ICERs) we used two-way sensitivity analysis. GDP Per capita of Islamic Republic of Iran (2012) adopted as cost-effectiveness threshold. Review of related literature highlighted the lack of rigorous evidence for clinical outcomes. Ultra low dose EOS imaging device is known as a safe intervention because of FDA, CE and CSA certificates. The rate of emitted X-ray was 2 to 18 fold lower for EOS compared to the conventional techniques (p<0.001). The Incremental Cost Effectiveness Ratio for EOS relative to CR calculated $50706 in baseline analysis (the first scenario) and $50714, $9446 respectively for the second and third scenarios. Considering the value of neither $42146 as upper limit, nor the first neither the second scenario could pass the cost-effectiveness threshold for Iran. EOS imaging technique might not be considered as a cost-effective intervention in routine practice of health system, especially within in-patient wards. Scenario analysis shows that, only in an optimum condition such as lower assembling costs and higher utilization rates

  19. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview In autumn the main focus was to process and handle CRAFT data and to perform the Summer08 MC production. The operational aspects were well covered by regular Computing Shifts, experts on duty and Computing Run Coordination. At the Computing Resource Board (CRB) in October a model to account for service work at Tier 2s was approved. The computing resources for 2009 were reviewed for presentation at the C-RRB. The quarterly resource monitoring is continuing. Facilities/Infrastructure operations Operations during CRAFT data taking ran fine. This proved to be a very valuable experience for T0 workflows and operations. The transfers of custodial data to most T1s went smoothly. A first round of reprocessing started at the Tier-1 centers end of November; it will take about two weeks. The Computing Shifts procedure was tested full scale during this period and proved to be very efficient: 30 Computing Shifts Persons (CSP) and 10 Computing Resources Coordinators (CRC). The shift program for the shut down w...

  20. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview During the past three months activities were focused on data operations, testing and re-enforcing shift and operational procedures for data production and transfer, MC production and on user support. Planning of the computing resources in view of the new LHC calendar in ongoing. Two new task forces were created for supporting the integration work: Site Commissioning, which develops tools helping distributed sites to monitor job and data workflows, and Analysis Support, collecting the user experience and feedback during analysis activities and developing tools to increase efficiency. The development plan for DMWM for 2009/2011 was developed at the beginning of the year, based on the requirements from the Physics, Computing and Offline groups (see Offline section). The Computing management meeting at FermiLab on February 19th and 20th was an excellent opportunity discussing the impact and for addressing issues and solutions to the main challenges facing CMS computing. The lack of manpower is particul...

  1. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction CMS distributed computing system performed well during the 2011 start-up. The events in 2011 have more pile-up and are more complex than last year; this results in longer reconstruction times and harder events to simulate. Significant increases in computing capacity were delivered in April for all computing tiers, and the utilisation and load is close to the planning predictions. All computing centre tiers performed their expected functionalities. Heavy-Ion Programme The CMS Heavy-Ion Programme had a very strong showing at the Quark Matter conference. A large number of analyses were shown. The dedicated heavy-ion reconstruction facility at the Vanderbilt Tier-2 is still involved in some commissioning activities, but is available for processing and analysis. Facilities and Infrastructure Operations Facility and Infrastructure operations have been active with operations and several important deployment tasks. Facilities participated in the testing and deployment of WMAgent and WorkQueue+Request...

  2. COMPUTING

    CERN Multimedia

    P. McBride

    The Computing Project is preparing for a busy year where the primary emphasis of the project moves towards steady operations. Following the very successful completion of Computing Software and Analysis challenge, CSA06, last fall, we have reorganized and established four groups in computing area: Commissioning, User Support, Facility/Infrastructure Operations and Data Operations. These groups work closely together with groups from the Offline Project in planning for data processing and operations. Monte Carlo production has continued since CSA06, with about 30M events produced each month to be used for HLT studies and physics validation. Monte Carlo production will continue throughout the year in the preparation of large samples for physics and detector studies ramping to 50 M events/month for CSA07. Commissioning of the full CMS computing system is a major goal for 2007. Site monitoring is an important commissioning component and work is ongoing to devise CMS specific tests to be included in Service Availa...

  3. Portable digital electronic radiography system with a solid-state area-imaging detector

    CERN Document Server

    Sawicka, B D; Sonnenburg, K

    1999-01-01

    A digital system for radiographic inspection was constructed in a portable version suitable for field use. The system uses typical film radiography sources, including sup 6 sup 0 Co, sup 1 sup 9 sup 2 1r and X-ray generators. Radiographic images are formed using an area-imaging scintillating detector coupled to a charge-coupled device camera and a portable industrial computer. Compared to film radiography, this technology offers imaging without wet-film processing, shorter exposure times, larger dynamic range, and digital imaging that permits compact archiving, easy data access and mathematical image processing to improve sensitivity. System performance is illustrated for typical applications, i.e., for radiographing valves and pipes. Using ' sup 1 sup 9 sup 2 Ir, the system works well on smaller water-filled valves and pipes; larger valves have to be drained. Work is under way to address this problem.

  4. A history of computers and computerized imaging.

    Science.gov (United States)

    Mixdorf, M A; Goldsworthy, R E

    1996-01-01

    The computers has revolutionized diagnostic imaging, making possible techniques such as computed tomography, magnetic resonance imaging, sonography and computed radiography. This article traces the historical development of computers and demonstrates how their brief association with the radiologic sciences has transformed diagnostic medicine.

  5. Digital reconstructed radiography quality control with software methods

    Science.gov (United States)

    Denis, Eloise; Beaumont, Stephane; Guedon, JeanPierre

    2005-04-01

    Nowadays, most of treatments for external radiotherapy are prepared with Treatment Planning Systems (TPS) which uses a virtual patient generated by a set of transverse slices acquired with a CT scanner of the patient in treatment position 1 2 3. In the first step of virtual simulation, the TPS is used to define a ballistic allowing a good target covering and the lowest irradiation for normal tissues. This parameters optimisation of the treatment with the TPS is realised with particular graphic tools allowing to: ×Contour the target, ×Expand the limit of the target in order to take into account contouring uncertainties, patient set up errors, movements of the target during the treatment (internal movement of the target and external movement of the patient), and beam's penumbra, ×Determine beams orientation and define dimensions and forms of the beams, ×Visualize beams on the patient's skin and calculate some characteristic points which will be tattooed on the patient to assist the patient set up before treating, ×Calculate for each beam a Digital Reconstructed Radiography (DRR) consisting in projecting the 3D CT virtual patient and beam limits with a cone beam geometry onto a plane. These DRR allow one for insuring the patient positioning during the treatment, essentially bone structures alignment by comparison with real radiography realized with the treatment X-ray source in the same geometric conditions (portal imaging). Then DRR are preponderant to insure the geometric accuracy of the treatment. For this reason quality control of its computation is mandatory4 . Until now, this control is realised with real test objects including some special inclusions4 5 . This paper proposes to use some numerical test objects to control the quality DRR calculation in terms of computation time, beam angle, divergence and magnification precision, spatial and contrast resolutions. The main advantage of this proposed method is to avoid a real test object CT acquisition

  6. Compreensão leitora de palavras e frases: elaboração de procedimento avaliativo

    Directory of Open Access Journals (Sweden)

    Adriana Marques de Oliveira

    2013-06-01

    Full Text Available Este estudo teve por objetivos elaborar o procedimento de avaliação da compreensão de leitura de palavras e frases e caracterizar o desempenho de escolares de 2º ano do Ensino Fundamental neste procedimento. O estudo foi dividido em duas partes: 1 elaboração das provas de avaliação da compreensão de leitura, composta por três provas: compreensão da palavra escrita (CPE, frase (CFE e frases a partir de figura (CFF e 2 aplicação das provas elaboradas em 120 escolares distribuídos em: GI, 60 escolares do ensino público municipal e GII, 60 escolares do ensino particular. A prova CPE obteve maior média de acertos, seguida da CFF e CFE para ambos os grupos, pois a figura auxilia no processo de extração do significado tanto da palavra como da frase. O procedimento elaborado, ao identificar as dificuldades inerentes do início do processo de alfabetização, mostrou-se eficaz para avaliar as habilidades iniciais da compreensão da leitura.

  7. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing activity had ramped down after the completion of the reprocessing of the 2012 data and parked data, but is increasing with new simulation samples for analysis and upgrade studies. Much of the Computing effort is currently involved in activities to improve the computing system in preparation for 2015. Operations Office Since the beginning of 2013, the Computing Operations team successfully re-processed the 2012 data in record time, not only by using opportunistic resources like the San Diego Supercomputer Center which was accessible, to re-process the primary datasets HTMHT and MultiJet in Run2012D much earlier than planned. The Heavy-Ion data-taking period was successfully concluded in February collecting almost 500 T. Figure 3: Number of events per month (data) In LS1, our emphasis is to increase efficiency and flexibility of the infrastructure and operation. Computing Operations is working on separating disk and tape at the Tier-1 sites and the full implementation of the xrootd federation ...

  8. Digital Radiography Qualification of Tube Welding

    Science.gov (United States)

    Carl, Chad

    2012-01-01

    The Orion Project will be directing Lockheed Martin to perform orbital arc welding on commodities metallic tubing as part of the Multi Purpose Crew Vehicle assembly and integration process in the Operations and Checkout High bay at Kennedy Space Center. The current method of nondestructive evaluation is utilizing traditional film based x-rays. Due to the high number of welds that are necessary to join the commodities tubing (approx 470), a more efficient and expeditious method of nondestructive evaluation is desired. Digital radiography will be qualified as part of a broader NNWG project scope.

  9. Radiography With the Patient in the centre

    DEFF Research Database (Denmark)

    Møller, Louise

    2016-01-01

    The health care system is becoming more technological, and at the same time, it is verbalized that the patient should be in the center. The purpose of this study was to illucidate how radiography with the patient in the center is performed and what patients and radiographers understand about cent...... focus and attention to the patient. Problems arise when more elements in the MR scan have a technical focus demanding attention and action; the humanistic element can be included and centered but not be in the center....

  10. Learning Styles of Radiography Students during Clinical Practice

    Science.gov (United States)

    Ward, L. Patrice

    2009-01-01

    The purpose of this study was to identify and describe the common learning styles of radiography students during clinical practice. Quantitative, descriptive research methodology identified the learning styles of radiography students. A single self-report questionnaire, developed to assess learning styles in clinical practice, was administered…

  11. (DRLs) for radiography examinations in north eastern Nigeria

    African Journals Online (AJOL)

    Diagnostic reference levels (DRLs) is an essential optimization tool in radiography and radiological sciences. The objective of the study is to establish DRL for radiography examinations in north eastern Nigeria. A Prospective cross- sectional study conducted in two university teaching hospitals in north eastern Nigeria.

  12. The profile of indications for radiography in the Neonatal Intensive ...

    African Journals Online (AJOL)

    Introduction. Radiography is a key diagnostic tool in paediatric care. A pro-active approach (including the use of radiography) is required to ensure e.ective management of these patients. Taking into account the widely documented harmful e.ects of ionising radiation and the small organ masses of neonates, the number of ...

  13. The frequency of various indications for plain chest radiography in ...

    African Journals Online (AJOL)

    2012-05-20

    May 20, 2012 ... Nigerian Journal of Clinical Practice • Oct-Dec 2013 • Vol 16 • Issue 4. Okpala, et al: The frequency of various indications of plain chest radiography in NAUTH, Nnewi. Methodology. All consecutive patients with request for plain chest radiography in our department from February 2009 were used for this ...

  14. Development of neutron detectors and neutron radiography at ...

    Indian Academy of Sciences (India)

    Apsara reactor has been used for a variety of applications in nuclear, aerospace, defense and metallurgical industries. The work done in the development of neutron detectors and neutron radiography is reported in this article. Keywords. Gas-filled neutron proportional counters; neutron radiography; hydride blis- ter.

  15. The value of panoramic radiography in assessing maxillary sinus inflammation

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae; Jung, Yun Hoa; Nah, Kyung Soo [Department of Oral and Maxillofacial Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    2008-12-15

    To evaluate the value of panoramic radiography in diagnosing maxillary sinus inflammation. A total of 214 maxillary sinuses from 114 panoramic radiographs were assessed in this study. Two independent experienced oral radiologists evaluated the images in random order for sinus inflammation. Using Cone beam CT images as the gold standard, the sensitivity and specificity of panoramic radiography were calculated, and inter- and intraobserver agreement for panoramic interpretation were obtained. The mean sensitivity and specificity of panoramic radiography were 81.0% and 85.6%, respectively. The weighted kappas for inter- and intraobserver agreement of panoramic radiography were 0.56 and 0.60, respectively. Panoramic radiography is a reasonably accurate method for diagnosing maxillary sinus inflammation and can be used for screening. However, additional examinations should be considered in patients with potentially significant pathology.

  16. Diagnostic radiography exposure increases the risk for thyroid microcarcinoma: a population-based case-control study.

    Science.gov (United States)

    Zhang, Yawei; Chen, Yingtai; Huang, Huang; Sandler, Jason; Dai, Min; Ma, Shuangge; Udelsman, Robert

    2015-09-01

    Thyroid cancer incidence and diagnostic radiography exposures, particularly computed tomography (CT) scanning and nuclear medicine examinations, have increased substantially in the USA. However, very few epidemiologic studies have directly investigated their associations. A population-based case-control study was conducted in Connecticut in 2010-2011, including 462 histologically confirmed incident thyroid cancer cases and 498 population-based controls. Multivariate unconditional logistic regression models were used to estimate the associations between diagnostic radiography and the risk of thyroid cancer, controlling for potential confounding factors. Exposure to any form of diagnostic radiography was associated with an increased risk of well-differentiated thyroid microcarcinoma [tumor size≤10 mm, odds ratio (OR)=2.76, 95% confidence interval (CI): 1.31-5.81]. The highest risk increase occurred with nuclear medicine examinations (excluding cardiology tests and thyroid uptake studies; OR=5.47, 95% CI: 2.10-14.23), followed by chest CT scanning (OR=4.30, 95% CI: 1.66-11.14), head and neck CT scanning (OR=3.88, 95% CI: 1.75-8.63), upper gastrointestinal series (OR=3.56, 95% CI: 1.54-8.21), lower gastrointestinal series (OR=3.29, 95% CI: 1.41-7.66), kidney radiography involving dye injection into a vein or artery (OR=3.21, 95% CI: 1.20-8.54), mammography (OR=2.95, 95% CI: 1.14-7.61), chest radiography (OR=2.93, 95% CI: 1.37-6.29), and abdomen CT scanning (OR=2.54, 95% CI: 1.02-6.30). No significant associations were found between these imaging modalities and thyroid tumors larger than 10 mm. This study provides the first direct evidence that CT scanning and nuclear medicine examinations are associated with an increased risk of thyroid cancer. The novel finding that an array of diagnostic radiography procedures are associated with thyroid microcarcinomas warrants further investigation.

  17. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  18. COMPUTING

    CERN Multimedia

    M. Kasemann P. McBride Edited by M-C. Sawley with contributions from: P. Kreuzer D. Bonacorsi S. Belforte F. Wuerthwein L. Bauerdick K. Lassila-Perini M-C. Sawley

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the comput...

  19. Computer-aided diagnosis in chest radiography: beyond nodules.

    NARCIS (Netherlands)

    Ginneken, B. van; Hogeweg, L.E.; Prokop, M.

    2009-01-01

    Chest radiographs are the most common exam in radiology. They are essential for the management of various diseases associated with high mortality and morbidity and display a wide range of findings, many of them subtle. In this survey we identify a number of areas beyond pulmonary nodules that could

  20. Miniature, mobile X-ray computed radiography system

    Science.gov (United States)

    Watson, Scott A; Rose, Evan A

    2017-03-07

    A miniature, portable x-ray system may be configured to scan images stored on a phosphor. A flash circuit may be configured to project red light onto a phosphor and receive blue light from the phosphor. A digital monochrome camera may be configured to receive the blue light to capture an article near the phosphor.

  1. Extraoral periapical radiography: A technique unveiled

    Directory of Open Access Journals (Sweden)

    Sujatha S Reddy

    2011-01-01

    Full Text Available Introduction: Extraoral periapical radiography (EOPAR is a technique where the film is placed extraorally overlying the tooth of interest and the X-ray beam is directed from the opposite side of the face. This technique was first proposed by Newman and Friedman (2003 and later modified by Chia-Hui Chen et al (2007 to assist certain patient populations who are unable to tolerate intraoral films/sensors. Materials and methods: An experimental case study was designed using dry skulls. The modified beam aiming device was assembled and positioned accordingly to the tooth of interest at vertical angulations of - 20 to - 30 for maxillary teeth and + 20 to + 30 for mandibular teeth. The X-ray beam was directed from the opposite side toward the film/sensor placed extraorally on the contralateral side. Once, the exposure parameters were established on dry skulls, the technique was validated on human volunteers. Results: A series of clinically useful radiographic images of the maxillary and mandibular premolars and molars were obtained using EOPA radiographic technique. Conclusion: EOPAR technique can be used to produce diagnostically useful radiographs of the maxillary and mandibular teeth. It is an effective approach for obtaining periapical radiographs in certain patient populations who are unable to tolerate intraoral films and/or sensors. Although this technique is not intended to be a substitute for conventional intraoral radiography, it is a useful supplement to our clinical practice.

  2. Clinical Applications of Reverse Panoramic Radiography

    Directory of Open Access Journals (Sweden)

    Sujatha S Reddy

    2011-09-01

    Full Text Available The essence of oral and maxil-lofacial radiology is not only to be an important tool in the diagnostic assessment of dental patients but also to equip the clinician with the ability to interpret images of certain maxillocraniofacial structures of importance to dental, medical and surgical practices. Although combinations of several conven-tional x-ray projections can be adequate in a number of clinical situations, radiographic assessment of certain craniofacial structures some-times needs to be facilitated by other imaging modalities. A not-so-recent development called reverse panoramic radiography may be a useful adjuvant to such a situation, at least in the near future. It is essentially a technique where the patient is placed backwards in the panoramic machine in a reverse position in such a way that x-ray beam is directed through the patient’s face and the exit beam then passes through the patient’s head on the opposite side where it is captured on the receptor. The following manuscript is an attempt to throw light on this technique and the impact it may have on dental, medical and surgical practices. The advantages and disadvantages of reverse panoramic radiography and it’s comparison to conventional panoramic radiographs and other skull views are also dis-cussed.

  3. Nuclear track radiography of 'hot' aerosol particles

    CERN Document Server

    Boulyga, S F; Kievets, M K; Lomonosova, E M; Zhuk, I V; Yaroshevich, O I; Perelygin, V P; Petrova, R I; Brandt, R; Vater, P

    1999-01-01

    Nuclear track radiography was applied to identify aerosol 'hot' particles which contain elements of nuclear fuel and fallout after Chernobyl NPP accident. For the determination of the content of transuranium elements in radioactive aerosols the measurement of the alpha-activity of 'hot' particles by SSNTD was used in this work, as well as radiography of fission fragments formed as a result of the reactions (n,f) and (gamma,f) in the irradiation of aerosol filters by thermal neutrons and high energy gamma quanta. The technique allowed the sizes and alpha-activity of 'hot' particles to be determined without extracting them from the filter, as well as the determination of the uranium content and its enrichment by sup 2 sup 3 sup 5 U, sup 2 sup 3 sup 9 Pu and sup 2 sup 4 sup 1 Pu isotopes. Sensitivity of determination of alpha activity by fission method is 5x10 sup - sup 6 Bq per particle. The software for the system of image analysis was created. It ensured the identification of track clusters on an optical imag...

  4. Quantitative proton radiography of an animal patient

    Science.gov (United States)

    Schneider, Uwe; Dellert, Matthias; Pedroni, Eros; Pemler, Peter; Besserer, Juergen; Moosburger, Martin; Theiler, Prisca; Kaser-Hotz, Barbara

    2003-06-01

    Images (with a spatial resolution of 1 mm x 1mm) were produced both, with range and range dilution information of the protons passing through a dog. The radiographies were taken prior to a proton radiotherapy treatment of a nasal tumor, while the dog patient was under anesthetics. The first image was created by calculating the mean range of the protons detected in each pixel. This image was compared to calculations of the treatment planning system based on a CT-scan of the dog. Errors in the calculated range could be detected. The second image was produced by calculating the width of the range spectrum in each pixel. This value is a measure of the dilution of the range due to tissue inhomogeneities. The dilution image can be used to indicate critical situations during proton therapy, to determine the safety margin around the tumor volume, or to optimise treatment. In a preliminary analysis of the radiography data we found range uncertainty and range dilution effects in the order of up to 10 mm.

  5. COMPUTING

    CERN Multimedia

    P. McBride

    It has been a very active year for the computing project with strong contributions from members of the global community. The project has focused on site preparation and Monte Carlo production. The operations group has begun processing data from P5 as part of the global data commissioning. Improvements in transfer rates and site availability have been seen as computing sites across the globe prepare for large scale production and analysis as part of CSA07. Preparations for the upcoming Computing Software and Analysis Challenge CSA07 are progressing. Ian Fisk and Neil Geddes have been appointed as coordinators for the challenge. CSA07 will include production tests of the Tier-0 production system, reprocessing at the Tier-1 sites and Monte Carlo production at the Tier-2 sites. At the same time there will be a large analysis exercise at the Tier-2 centres. Pre-production simulation of the Monte Carlo events for the challenge is beginning. Scale tests of the Tier-0 will begin in mid-July and the challenge it...

  6. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

    Introduction Computing continued with a high level of activity over the winter in preparation for conferences and the start of the 2012 run. 2012 brings new challenges with a new energy, more complex events, and the need to make the best use of the available time before the Long Shutdown. We expect to be resource constrained on all tiers of the computing system in 2012 and are working to ensure the high-priority goals of CMS are not impacted. Heavy ions After a successful 2011 heavy-ion run, the programme is moving to analysis. During the run, the CAF resources were well used for prompt analysis. Since then in 2012 on average 200 job slots have been used continuously at Vanderbilt for analysis workflows. Operations Office As of 2012, the Computing Project emphasis has moved from commissioning to operation of the various systems. This is reflected in the new organisation structure where the Facilities and Data Operations tasks have been merged into a common Operations Office, which now covers everything ...

  7. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion The Tier 0 infrastructure was able to repack and promptly reconstruct heavy-ion collision data. Two copies were made of the data at CERN using a large CASTOR disk pool, and the core physics sample was replicated ...

  8. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the co...

  9. COMPUTING

    CERN Multimedia

    M. Kasemann

    CCRC’08 challenges and CSA08 During the February campaign of the Common Computing readiness challenges (CCRC’08), the CMS computing team had achieved very good results. The link between the detector site and the Tier0 was tested by gradually increasing the number of parallel transfer streams well beyond the target. Tests covered the global robustness at the Tier0, processing a massive number of very large files and with a high writing speed to tapes.  Other tests covered the links between the different Tiers of the distributed infrastructure and the pre-staging and reprocessing capacity of the Tier1’s: response time, data transfer rate and success rate for Tape to Buffer staging of files kept exclusively on Tape were measured. In all cases, coordination with the sites was efficient and no serious problem was found. These successful preparations prepared the ground for the second phase of the CCRC’08 campaign, in May. The Computing Software and Analysis challen...

  10. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction The first data taking period of November produced a first scientific paper, and this is a very satisfactory step for Computing. It also gave the invaluable opportunity to learn and debrief from this first, intense period, and make the necessary adaptations. The alarm procedures between different groups (DAQ, Physics, T0 processing, Alignment/calibration, T1 and T2 communications) have been reinforced. A major effort has also been invested into remodeling and optimizing operator tasks in all activities in Computing, in parallel with the recruitment of new Cat A operators. The teams are being completed and by mid year the new tasks will have been assigned. CRB (Computing Resource Board) The Board met twice since last CMS week. In December it reviewed the experience of the November data-taking period and could measure the positive improvements made for the site readiness. It also reviewed the policy under which Tier-2 are associated with Physics Groups. Such associations are decided twice per ye...

  11. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction During the past six months, Computing participated in the STEP09 exercise, had a major involvement in the October exercise and has been working with CMS sites on improving open issues relevant for data taking. At the same time operations for MC production, real data reconstruction and re-reconstructions and data transfers at large scales were performed. STEP09 was successfully conducted in June as a joint exercise with ATLAS and the other experiments. It gave good indication about the readiness of the WLCG infrastructure with the two major LHC experiments stressing the reading, writing and processing of physics data. The October Exercise, in contrast, was conducted as an all-CMS exercise, where Physics, Computing and Offline worked on a common plan to exercise all steps to efficiently access and analyze data. As one of the major results, the CMS Tier-2s demonstrated to be fully capable for performing data analysis. In recent weeks, efforts were devoted to CMS Computing readiness. All th...

  12. Comparative assessment of panoramic radiography and CBCT imaging for radiodiagnostics in the posterior maxilla.

    Science.gov (United States)

    Shahbazian, Maryam; Vandewoude, Charlotte; Wyatt, Jan; Jacobs, Reinhilde

    2014-01-01

    The purpose of this study was to assess whether and how the information obtained by means of cone beam computed tomography (CBCT) on maxillary posterior teeth differs from that obtained by panoramic radiography. From 157 subjects (mean age 48 years, range 19-84 years; 89 females) referred to the oral imaging center, a pair of panoramic and CBCT images was selected for further analysis. Both imaging modalities were analyzed to determine the topographic relationship of maxillary teeth to the sinus floor. Pathologic conditions, apical periodontitis, and presence of soft tissue thickening were also examined with both techniques. CBCT showed an intimate relationship of the first and second molar with the maxillary sinus in 54 and 38%, respectively. Thirty-nine apical periodontitis lesions causing reactive changes in the maxillary sinus were detected by CBCT, while just six of them were diagnosed with panoramic imaging. A total of 26 teeth with apical extension to the maxillary sinus were detected with CBCT, from which two could be identified with panoramic radiography. This study emphasizes that anatomical and pathological involvement of the maxillary sinus in relation to posterior teeth is considerably high. It is of clinical importance that the 3D nature of CBCT imaging allowed a better assessment of the relationship between the maxillary sinus and posterior root apices compared to the low detection on panoramic radiographs. CBCT imaging can be a valuable adjunct in radioanatomical and radiodiagnostic observations in the posterior maxilla. It may better visualize maxillary sinus involvement for posterior upper teeth than panoramic radiography.

  13. Digital Radiography for Determination of Primary Tooth Length: In Vivo and Ex Vivo Studies

    Directory of Open Access Journals (Sweden)

    Maria D. Basso

    2015-01-01

    Full Text Available Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm. The apparent tooth length (APTL was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0, whereas the actual tooth length (ACTL was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed (P≤0.48 between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

  14. Radiographers' Ability to Detect Low-Contrast Detail in Digital Radiography Systems.

    Science.gov (United States)

    Alsleem, Haney; Davidson, Robert

    2015-01-01

    To evaluate radiographers' ability to detect low-contrast detail using various digital planar radiographic systems. A low-contrast detail phantom was placed between two 5-cm thick Perspex sheets (Lucite International). Images were obtained using different kilovoltage peak and milliamperage second (mAs) settings with computed radiography (CR), indirect conversion digital radiography (IDR), and direct conversion digital radiography (DR) systems. Six groups of 6 radiographers were asked to score 39 images; each group scored 2 images from each system for a total of 6 images. The seventh group scored only one image from each system for a total of 3 images. The radiographers' results were compared with the results of analyzer software. The inverse image quality factor was used to measure low-contrast detail detectability performance. Radiographers performed significantly worse than the computerized software in determining low-contrast detail in planar radiographic images (P detail detectability performance. On average, radiographers were able to detect increased image quality resulting from increased mAs. Radiographers reached results similar to the software regarding whether IDR and DR have better detectability performances than CR. Differences found among individual radiographers were not as significant with DR. When radiographers' performance in detecting low-contrast detail was evaluated and compared with that of the software, radiographers exhibited poorer performances. Because radiographers are responsible for image quality optimization, additional training might improve their ability to detect low-contrast detail in DR systems.

  15. Use of VAP3D software for production and manipulation of synthetic radiographies of anthropomorphic models

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Lindeval Fernandes de, E-mail: lindeval@dmat.ufrr.b [Universidade Federal de Roraima (DMAT/UFRR), Boa Vista, RR (Brazil). Dept. de Matematica; Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Vieira, Jose W. [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Universidade de Pernambuco (EPP/UPE), Recife, PE (Brazil). Escola Politecnica de Pernambuco; Lima, Fernando R.A., E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Leal Neto, Viriato [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2011-07-01

    The Grupo de Dosimetria Numerica has developed exposure computational models (ECM) involving a Monte Carlo code and voxel phantoms to simulate various situations of internal and external exposure to ionizing radiation. Most analyses of the produced results are presented in tables and graphics formats. An alternative to this traditional way of analyzing results is to save voxels of Regions of Interest (ROI) of the phantom irradiated with information like the location of the voxel and the energy deposited in it during the simulation. Such information can be saved to a text file and later turned into 3D objects. In this paper the VAP3D software has been used to read text files produced in simulations using the ECM of DEN (Nuclear Energy Dept. - UFPE), converting them into binary files of the type RAW, and visualize them. In order to reflect the radiosensitivity of the organs and tissues suggested by ICRP-60, for conversion of text file to binary, of the energy deposited values are multiplied by the weighting factor of the tissue to which the voxel belongs. The result of the multiplication is normalized to the interval [0, 255]. The files transformed are referred herein as synthetic radiographies. In VAP3D software, it is possible to generate stacks from theses radiographies in transverse, sagittal and coronal directions. In order to illustrate the production of synthetic radiographies, some images are presented in this paper, and dosimetric results are obtained from a variety of ROIs of the phantoms of DEN for radiological exams. (author)

  16. Proton radiography for inline treatment planning and positioning verification of small animals.

    Science.gov (United States)

    Müller, Johannes; Neubert, Christian; von Neubeck, Cläre; Baumann, Michael; Krause, Mechthild; Enghardt, Wolfgang; Bütof, Rebecca; Dietrich, Antje; Lühr, Armin

    2017-11-01

    As proton therapy becomes increasingly well established, there is a need for high-quality clinically relevant in vivo data to gain better insight into the radiobiological effects of proton irradiation on both healthy and tumor tissue. This requires the development of easily applicable setups that allow for efficient, fractionated, image-guided proton irradiation of small animals, the most widely used pre-clinical model. Here, a method is proposed to perform dual-energy proton radiography for inline positioning verification and treatment planning. Dual-energy proton radiography exploits the differential enhancement of object features in two successively measured two-dimensional (2D) dose distributions at two different proton energies. The two raw images show structures that are dominated by energy absorption (absorption mode) or scattering (scattering mode) of protons in the object, respectively. Data post-processing allowed for the separation of both signal contributions in the respective images. The images were evaluated regarding recognizable object details and feasibility of rigid registration to acquired planar X-ray scans. Robust, automated rigid registration of proton radiography and planar X-ray images in scattering mode could be reliably achieved with the animal bedding unit used as registration landmark. Distinguishable external and internal features of the imaged mouse included the outer body contour, the skull with substructures, the lung, abdominal structures and the hind legs. Image analysis based on the combined information of both imaging modes allowed image enhancement and calculation of 2D water-equivalent path length (WEPL) maps of the object along the beam direction. Fractionated irradiation of exposed target volumes (e.g., subcutaneous tumor model or brain) can be realized with the suggested method being used for daily positioning and range determination. Robust registration of X-ray and proton radiography images allows for the irradiation of

  17. Effect of vertical angulation to dose of thyroid glands in periapical radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hosoi, Keitaro; Satoh, Keiji; Furumoto, Keiichi (Nippon Dental Univ., Tokyo (Japan). School of Dentistry)

    1992-10-01

    Much attention has been given to reducing the dose of radiation in dental radiography in terms of the highest risk for the head and neck. Organ doses in intraoral radiography vary greatly with subtle differences in vertical angulation. Quantitative determination of doses delivered to the thyroid gland is thus necessary in determining adequate doses and risk for dental radiography. A personal computer program, prepared for estimating organ doses under various radiographic conditions, was used to evaluate the effect of vertical angulation on the dose delivered to the thyroid gland in radiography of the maxillary and mandibular incisors. Review of the literature revealed that the calculated dose delivered to the thyroid gland is approximately in accordance with the data of the actual determination under the same radiographic conditions. The dose-dependence of radiation delivered to the thyroid gland on vertical angulation of the maxilla was much more than that of the mandible. In the mandible, the dose delivered to the thyroid gland increased about three fold at a field size of 6 cm[phi] and about 1.5 fold at 8 cm[phi] when the vertical angulation changed from -40deg to 0deg. In the maxilla, the delivered dose increased about 480 times at a field size of 6 cm[phi] when vertical angulation changed from 0deg to 50deg and rapidly increased about 280 times at 8 cm[phi] when the angulation changed from 0deg to 40deg. The dose of radiation delivered to the thyroid gland was evaluated as a function of product of the irradiated volume within the primary beam directed at the thyroid gland and the inverse square of the distance between a subject's surface and the thyroid gland. (N.K.).

  18. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing operation has been lower as the Run 1 samples are completing and smaller samples for upgrades and preparations are ramping up. Much of the computing activity is focusing on preparations for Run 2 and improvements in data access and flexibility of using resources. Operations Office Data processing was slow in the second half of 2013 with only the legacy re-reconstruction pass of 2011 data being processed at the sites.   Figure 1: MC production and processing was more in demand with a peak of over 750 Million GEN-SIM events in a single month.   Figure 2: The transfer system worked reliably and efficiently and transferred on average close to 520 TB per week with peaks at close to 1.2 PB.   Figure 3: The volume of data moved between CMS sites in the last six months   The tape utilisation was a focus for the operation teams with frequent deletion campaigns from deprecated 7 TeV MC GEN-SIM samples to INVALID datasets, which could be cleaned up...

  19. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

      Introduction Computing activity has been running at a sustained, high rate as we collect data at high luminosity, process simulation, and begin to process the parked data. The system is functional, though a number of improvements are planned during LS1. Many of the changes will impact users, we hope only in positive ways. We are trying to improve the distributed analysis tools as well as the ability to access more data samples more transparently.  Operations Office Figure 2: Number of events per month, for 2012 Since the June CMS Week, Computing Operations teams successfully completed data re-reconstruction passes and finished the CMSSW_53X MC campaign with over three billion events available in AOD format. Recorded data was successfully processed in parallel, exceeding 1.2 billion raw physics events per month for the first time in October 2012 due to the increase in data-parking rate. In parallel, large efforts were dedicated to WMAgent development and integrati...

  20. COMPUTING

    CERN Multimedia

    2010-01-01

    Introduction Just two months after the “LHC First Physics” event of 30th March, the analysis of the O(200) million 7 TeV collision events in CMS accumulated during the first 60 days is well under way. The consistency of the CMS computing model has been confirmed during these first weeks of data taking. This model is based on a hierarchy of use-cases deployed between the different tiers and, in particular, the distribution of RECO data to T1s, who then serve data on request to T2s, along a topology known as “fat tree”. Indeed, during this period this model was further extended by almost full “mesh” commissioning, meaning that RECO data were shipped to T2s whenever possible, enabling additional physics analyses compared with the “fat tree” model. Computing activities at the CMS Analysis Facility (CAF) have been marked by a good time response for a load almost evenly shared between ALCA (Alignment and Calibration tasks - highest p...

  1. COMPUTING

    CERN Multimedia

    Matthias Kasemann

    Overview The main focus during the summer was to handle data coming from the detector and to perform Monte Carlo production. The lessons learned during the CCRC and CSA08 challenges in May were addressed by dedicated PADA campaigns lead by the Integration team. Big improvements were achieved in the stability and reliability of the CMS Tier1 and Tier2 centres by regular and systematic follow-up of faults and errors with the help of the Savannah bug tracking system. In preparation for data taking the roles of a Computing Run Coordinator and regular computing shifts monitoring the services and infrastructure as well as interfacing to the data operations tasks are being defined. The shift plan until the end of 2008 is being put together. User support worked on documentation and organized several training sessions. The ECoM task force delivered the report on “Use Cases for Start-up of pp Data-Taking” with recommendations and a set of tests to be performed for trigger rates much higher than the ...

  2. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction A large fraction of the effort was focused during the last period into the preparation and monitoring of the February tests of Common VO Computing Readiness Challenge 08. CCRC08 is being run by the WLCG collaboration in two phases, between the centres and all experiments. The February test is dedicated to functionality tests, while the May challenge will consist of running at all centres and with full workflows. For this first period, a number of functionality checks of the computing power, data repositories and archives as well as network links are planned. This will help assess the reliability of the systems under a variety of loads, and identifying possible bottlenecks. Many tests are scheduled together with other VOs, allowing the full scale stress test. The data rates (writing, accessing and transfer¬ring) are being checked under a variety of loads and operating conditions, as well as the reliability and transfer rates of the links between Tier-0 and Tier-1s. In addition, the capa...

  3. COMPUTING

    CERN Multimedia

    Contributions from I. Fisk

    2012-01-01

    Introduction The start of the 2012 run has been busy for Computing. We have reconstructed, archived, and served a larger sample of new data than in 2011, and we are in the process of producing an even larger new sample of simulations at 8 TeV. The running conditions and system performance are largely what was anticipated in the plan, thanks to the hard work and preparation of many people. Heavy ions Heavy Ions has been actively analysing data and preparing for conferences.  Operations Office Figure 6: Transfers from all sites in the last 90 days For ICHEP and the Upgrade efforts, we needed to produce and process record amounts of MC samples while supporting the very successful data-taking. This was a large burden, especially on the team members. Nevertheless the last three months were very successful and the total output was phenomenal, thanks to our dedicated site admins who keep the sites operational and the computing project members who spend countless hours nursing the...

  4. COMPUTING

    CERN Multimedia

    P. MacBride

    The Computing Software and Analysis Challenge CSA07 has been the main focus of the Computing Project for the past few months. Activities began over the summer with the preparation of the Monte Carlo data sets for the challenge and tests of the new production system at the Tier-0 at CERN. The pre-challenge Monte Carlo production was done in several steps: physics generation, detector simulation, digitization, conversion to RAW format and the samples were run through the High Level Trigger (HLT). The data was then merged into three "Soups": Chowder (ALPGEN), Stew (Filtered Pythia) and Gumbo (Pythia). The challenge officially started when the first Chowder events were reconstructed on the Tier-0 on October 3rd. The data operations teams were very busy during the the challenge period. The MC production teams continued with signal production and processing while the Tier-0 and Tier-1 teams worked on splitting the Soups into Primary Data Sets (PDS), reconstruction and skimming. The storage sys...

  5. A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization

    Energy Technology Data Exchange (ETDEWEB)

    Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco; Acchiappati, Domenico [Alma Mater Studiorum, Physics Department, University of Bologna, 40127 Bologna, Italy and S.C. di Fisica Sanitaria ' ' Azienda USL di Modena' ' 41100 Modena (Italy); Alma Mater Studiorum, Physics Department, University of Bologna, 40127 Bologna (Italy); Arcispedale Santa Maria Nuova, 42123 Reggio Emilia (Italy); S.C. di Fisica Sanitaria ' ' Azienda USL di Modena' ' 41100 Modena (Italy)

    2011-08-15

    Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

  6. Image Enhancement for High frame-rate Neutron Radiography

    OpenAIRE

    Saito, Y; Ito, D.

    2015-01-01

    High frame rate neutron radiography has been utilized to investigate two-phase flow in a metallic duct. However, images obtained by high frame-rate neutron radiography suffered from severe statistical noise due to its short exposure time. In this study, a spatio-temporal filter was applied to reduce the noise in the sequence images obtained by high frame-rate neutron radiography. Experiments were performed at the B4-port of the Research Reactor Institute, Kyoto University, which has a thermal...

  7. Padronização da anestesia em suínos para procedimentos cirúrgicos cardiovasculares experimentais

    Directory of Open Access Journals (Sweden)

    Glaucylara Reis Geovanini

    2008-08-01

    Full Text Available JUSTIFICATIVA E OBJETIVO: Embora sejam os cães os animais mais utilizados em Cirurgia Experimental, nota-se crescente utilização de ovinos, bovinos e suínos como modelos para experimentação científica. Assim, faz-se necessário maior aprendizado de seu tratamento e padronizações básicas para os procedimentos cirúrgicos mais complexos em suínos. O objetivo foi avaliar a sedação e analgesia, obtidas pela injeção intramuscular de midazolam e cetamina e anestesia local com lidocaína a 2% sem vasoconstritor, na realização de traqueostomia, dissecção de artéria e veia femorais. MÉTODO: A freqüência cardíaca e o reflexo córneo-palpebral foram avaliados logo no início da sedação, durante os procedimentos cirúrgicos descritos e após seu término. Foram utilizados oito suínos fornecidos por fazendas locais sem tratamento prévio da raça Large White, com peso de 35 a 42 quilos que receberam injeção intramuscular de 22 mg.kg-1 de cetamina e 0,3 mg.kg-1 de midazolam. RESULTADOS: A abordagem anestésica nesses animais, de difíceis intubação e acesso aos vasos profundos, provou ser segura para sedação e analgesia através do método utilizado: acesso intramuscular. CONCLUSÃO: Obteve-se adequado plano de anestesia para o procedimento proposto.

  8. Assessment of panoramic radiography as a national oral examination tool: review of the literature

    OpenAIRE

    Choi, Jin-Woo

    2011-01-01

    Purpose The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. Materials and Methods This report was carried out by review of the literatures. Results Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Conclusion Panoramic radiography will improve the effi...

  9. Digital Subtraction Radiography - A Technique Revisited

    Directory of Open Access Journals (Sweden)

    Anshul Mehra

    2007-01-01

    Full Text Available Digital imaging has changed the scenario of medical and dental imaging as it has been able to address many limitations associated with traditional film based radiograph. However, subtle changes on the image are still difficult to appreciate by the human eye because the changes are buried in a background of normal anatomic structures, and are not clearly evident. Digital subtraction radiography is one of the image enhancing technique which addresses this problem and has found its use in various fields of dentistry in the recent past. However, there is lack of review in the literature regarding this widely used technique. The purpose of this article is to present an overview of this technique and its uses in various fields of dentistry.

  10. Vertex occlusal radiography in localizing unerupted mesiodentes

    Directory of Open Access Journals (Sweden)

    P Chalakkal

    2011-01-01

    Full Text Available The aim was to compare the vertex occlusal projection with the anterior maxillary occlusal projection in localizing the position of mesiodentes. Mesiodentes were observed in an 8-year-old boy with an anterior maxillary occlusal radiograph. A vertex occlusal radiograph was taken to compare it with the former in terms of mesiodentes localization with respect to the maxillary central incisors. The vertex occlusal radiograph provided greater details of the position and proximity of mesiodentes with respect to the long axis of maxillary central incisors in comparison to the anterior maxillary occlusal radiograph. Vertex occlusal radiography is an important diagnostic tool in diagnosing the presence, position, and proximity of mesiodentes with respect to the long axis of normally aligned maxillary central incisors. However, it is not recommended for routine use in a patient as its radiation dose is higher than conventional intraoral radiographic methods.

  11. Intraoral digital radiography: elements of effective imaging.

    Science.gov (United States)

    Cederberg, Robert

    2012-10-01

    Intraoral digital imaging has evolved from an experimental and sometimes disparaged technique in the mid 1980s to a reliable and ubiquitously used technology today. There are many advantages for use of digital radiographic techniques in dentistry, one of the chief ones being patient dose reduction. However, as important as dose reduction is for safe and effective radiography, practicing dentists would also like to understand the fundamental differences between digital system configurations so they may be able to make an informed choice as to which system best fits their needs. In addition, there has been considerable debate on the following topics: sensor technology; factors associated with image display; optimum techniques for image manipulation; and image storage, retrieval, and archiving. This article provides insight into these and other elements of effective imaging in intraoral digital imaging.

  12. Oral history in radiography: Listening to pioneers

    Energy Technology Data Exchange (ETDEWEB)

    Ferris, Christine [International Development Facilitator, Robert Winston Building, Faculty of Health and Wellbeing, Sheffield Hallam University, Sheffield S10 2BP (United Kingdom)], E-mail: c.m.ferris@shu.ac.uk; Winslow, Michelle [University of Sheffield, Oral History Society, Academic Unit of Supportive Care, Sykes House, Little Common Lane, Sheffield S11 9NE (United Kingdom)], E-mail: m.winslow@sheffield.ac.uk

    2009-12-15

    We explore the professional value of the collection and analysis of oral histories in the history of radiography. Drawing on oral histories collected from radiographers, we analyse accounts of experiences to identify common themes, some of which are of current significance, whilst others have faded from existence. 15 oral histories were collected from radiographers whose combined practice spans the years 1930-1973. The sample consists of 6 male and 9 female radiographers. Themes identified in the oral histories include radiographers as invisible pioneers who worked in professionally unclaimed territory and their dangerous working environment. The oral histories reveal the working world of the radiographer as having encompassed a practice ethos where challenges became an accepted part of work. We gain insight into less observable aspects of the radiographer's role, the difficulties they faced, how they invented techniques and equipment, and how they managed their practice including protecting the public from ionising radiation sources.

  13. Image rejects in general direct digital radiography

    Science.gov (United States)

    Rosanowsky, Tine Blomberg; Jensen, Camilla; Wah, Kenneth Hong Ching

    2015-01-01

    Background The number of rejected images is an indicator of image quality and unnecessary imaging at a radiology department. Image reject analysis was frequent in the film era, but comparably few and small studies have been published after converting to digital radiography. One reason may be a belief that rejects have been eliminated with digitalization. Purpose To measure the extension of deleted images in direct digital radiography (DR), in order to assess the rates of rejects and unnecessary imaging and to analyze reasons for deletions, in order to improve the radiological services. Material and Methods All exposed images at two direct digital laboratories at a hospital in Norway were reviewed in January 2014. Type of examination, number of exposed images, and number of deleted images were registered. Each deleted image was analyzed separately and the reason for deleting the image was recorded. Results Out of 5417 exposed images, 596 were deleted, giving a deletion rate of 11%. A total of 51.3% were deleted due to positioning errors and 31.0% due to error in centering. The examinations with the highest percentage of deleted images were the knee, hip, and ankle, 20.6%, 18.5%, and 13.8% respectively. Conclusion The reject rate is at least as high as the deletion rate and is comparable with previous film-based imaging systems. The reasons for rejection are quite different in digital systems. This falsifies the hypothesis that digitalization would eliminates rejects. A deleted image does not contribute to diagnostics, and therefore is an unnecessary image. Hence, the high rates of deleted images have implications for management, training, education, as well as for quality. PMID:26500784

  14. Radiography and tomography with polarized neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Treimer, Wolfgang, E-mail: treimer@helmholtz-berlin.de [University of Applied Sciences, Beuth Hochschule für Technik Berlin, Department Mathematics Physics and Chemistry, Luxemburgerstr. 10, D-13353 Berlin (Germany); Helmholtz Zentrum für Materialien und Energie, Department G – GTOMO, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany)

    2014-01-15

    Neutron imaging became important when, besides providing impressive radiographic and tomographic images of various objects, physical, quantification of chemical, morphological or other parameters could be derived from 2D or 3D images. The spatial resolution of approximately 50 µm (and less) yields real space images of the bulk of specimens with more than some cm{sup 3} in volume. Thus the physics or chemistry of structures in a sample can be compared with scattering functions obtained e.g. from neutron scattering. The advantages of using neutrons become more pronounced when the neutron spin comes into play. The interaction of neutrons with magnetism is unique due to their low attenuation by matter and because their spin is sensitive to magnetic fields. Magnetic fields, domains and quantum effects such as the Meissner effect and flux trapping can only be visualized and quantified in the bulk of matter by imaging with polarized neutrons. This additional experimental tool is gaining more and more importance. There is a large number of new fields that can be investigated by neutron imaging, not only in physics, but also in geology, archeology, cultural heritage, soil culture, applied material research, magnetism, etc. One of the top applications of polarized neutron imaging is the large field of superconductivity where the Meissner effect and flux pinning can be visualized and quantified. Here we will give a short summary of the results achieved by radiography and tomography with polarized neutrons. - Highlights: • Radiography and tomography with polarized neutrons yield new results concerning the suppressed Meissner effect and magnetic flux trapping. • Suppressed Meissner effect was observed in pure lead samples and niobium. • Trapped magnetic fields in cylindrical Pb samples are squeezed around the rod axis. • The shape and the amount of trapped fields could be determined and quantified.

  15. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction The Computing Team successfully completed the storage, initial processing, and distribution for analysis of proton-proton data in 2011. There are still a variety of activities ongoing to support winter conference activities and preparations for 2012. Heavy ions The heavy-ion run for 2011 started in early November and has already demonstrated good machine performance and success of some of the more advanced workflows planned for 2011. Data collection will continue until early December. Facilities and Infrastructure Operations Operational and deployment support for WMAgent and WorkQueue+Request Manager components, routinely used in production by Data Operations, are provided. The GlideInWMS and components installation are now deployed at CERN, which is added to the GlideInWMS factory placed in the US. There has been new operational collaboration between the CERN team and the UCSD GlideIn factory operators, covering each others time zones by monitoring/debugging pilot jobs sent from the facto...

  16. SU-E-I-15: Comparison of Radiation Dose for Radiography and EOS in Adolescent Scoliosis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B; Walz-Flannigan, A [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: To estimate patient radiation dose for whole spine imaging using EOS, a new biplanar slot-scanning radiographic system and compare with standard scoliosis radiography. Methods: The EOS imaging system (EOS Imaging, Paris, France) consists of two orthogonal x-ray fan beams which simultaneously acquire frontal and lateral projection images of a standing patient. The patient entrance skin air kerma was measured for each projection image using manufacturer-recommended exposure parameters for spine imaging. Organ and effective doses were estimated using a commercially-available Monte Carlo simulation program (PCXMC, STUK, Radiation and Nuclear Safety Authority, Helsinki, Finland) for a 15 year old mathematical phantom model. These results were compared to organ and effective dose estimated for scoliosis radiography using computed radiography (CR) with standard exposure parameters obtained from a survey of pediatric radiographic projections. Results: The entrance skin air kerma for EOS was found to be 0.18 mGy and 0.33 mGy for posterior-anterior (PA) and lateral projections, respectively. This compares to 0.76 mGy and 1.4 mGy for CR, PA and lateral projections. Effective dose for EOS (PA and lateral projections combined) is 0.19 mSv compared to 0.51 mSv for CR. Conclusion: The EOS slot-scanning radiographic system allows for reduced patient radiation dose in scoliosis patients as compared to standard CR radiography.

  17. A physical model of multiple-image radiography

    Science.gov (United States)

    Khelashvili, Gocha; Brankov, Jovan G.; Chapman, Dean; Anastasio, Mark A.; Yang, Yongyi; Zhong, Zhong; Wernick, Miles N.

    2006-01-01

    We recently proposed a phase-sensitive x-ray imaging method called multiple-image radiography (MIR), which is an improvement on the diffraction-enhanced imaging technique. MIR simultaneously produces three images, depicting separately the effects of absorption, refraction and ultra-small-angle scattering of x-rays, and all three MIR images are virtually immune to degradation caused by scattering at higher angles. Although good results have been obtained using MIR, no quantitative model of the imaging process has yet been developed. In this paper, we present a theoretical prediction of the MIR image values in terms of fundamental physical properties of the object being imaged. We use radiative transport theory to model the beam propagation, and we model the object as a stratified medium containing discrete scattering particles. An important finding of our analysis is that the image values in all three MIR images are line integrals of various object parameters, which is an essential property for computed tomography to be achieved with conventional reconstruction methods. Our analysis also shows that MIR truly separates the effects of absorption, refraction and ultra-small-angle scattering for the case considered. We validate our analytical model using real and simulated imaging data.

  18. Evaluation of a new type of direct digital radiography machine ...

    African Journals Online (AJOL)

    ray scanning system for medical use. Method. Radiation dose, image quality, diagnostic capability and clinical utility of the unit were compared with those of conventional radiography. Results. Radiation doses ranged from 3% to 5% of ...

  19. COMPUTING

    CERN Multimedia

    M. Kasemann

    CMS relies on a well functioning, distributed computing infrastructure. The Site Availability Monitoring (SAM) and the Job Robot submission have been very instrumental for site commissioning in order to increase availability of more sites such that they are available to participate in CSA07 and are ready to be used for analysis. The commissioning process has been further developed, including "lessons learned" documentation via the CMS twiki. Recently the visualization, presentation and summarizing of SAM tests for sites has been redesigned, it is now developed by the central ARDA project of WLCG. Work to test the new gLite Workload Management System was performed; a 4 times increase in throughput with respect to LCG Resource Broker is observed. CMS has designed and launched a new-generation traffic load generator called "LoadTest" to commission and to keep exercised all data transfer routes in the CMS PhE-DEx topology. Since mid-February, a transfer volume of about 12 P...

  20. Radiation dose estimation of patients undergoing lumbar spine radiography

    OpenAIRE

    Prince Kwabena Gyekye; Adu Simon; Emi-Reynolds Geoffrey; Yeboah Johnson; Inkoom Stephen; Cynthia Kaikor Engmann; Wotorchi-Gordon Samuel

    2013-01-01

    Radiation dose to organs of 100 adult patients undergoing lumbar spine (LS) radiography at a University Hospital have been assessed. Free in air kerma measurement using an ionization chamber was used for the patient dosimetry. Organ and effective dose to the patients were estimated using PCXMC (version 1.5) software. The organs that recorded significant dose due to LS radiography were lungs, stomach, liver, adrenals, kidney, pancreas, spleen, galbladder, and the heart. It was observed that th...

  1. Advances in digital industrial radiology - New application areas beyond film radiography

    Science.gov (United States)

    Ewert, Uwe

    2013-01-01

    Similar to the success story of digital photography a major upheaval has been observed in digital industrial radiology. Digital Detector Arrays enable the increase of contrast sensitivity up to a factor of 10 in comparison to film radiography. Computed radiography with phosphor imaging plates substitutes film applications. The increased sensitivity of digital detectors enables the efficient usage for dimensional measurements and functionality tests substituting manual maintenance. The measurement of wall thickness and corrosion status is state of the art in petrochemical industry. X-ray back scatter techniques have been applied in safety and security relevant applications with single sided access of source and detector. Computed tomography (CT) applications cover the range from m to nm scale. The scope of CT applications changes from flaw detection to dimensional measurement in industry. Mobile computed tomography is applied for in-service radiographic crack detection and sizing in welded pipes in nuclear power industry and aerospace applications. CT has been applied for evaluation of hot cracking susceptibility of modern weld alloys. In combination with modified varestraint transvarestraint tests (MVT) the cumulative crack length as function of stress and depth was determined. This enables the quantitative characterization of the weldability properties of different materials.

  2. Substantial CT radiation dose reduction does not affect the preference for CT over direct digital radiography to diagnose isolated zygomatic fractures: a study in human cadavers

    NARCIS (Netherlands)

    S. van der Duim; Dr. Martijn de Groot; W.P. Krijnen; B. van Minnen; A. Meijer; R. Hartman; R. Rozema

    2016-01-01

    Introduction: Zygomatic fractures can be diagnosed with either computed tomography (CT) or direct digital radiography (DR). The aim of the present study was to assess the effect of CT dose reduction on the preference for facial CT versus DR for accurate diagnosis of isolated zygomatic

  3. Modeling experimental plasma diagnostics in the FLASH code: proton radiography

    Science.gov (United States)

    Flocke, Norbert; Weide, Klaus; Feister, Scott; Tzeferacos, Petros; Lamb, Donald

    2017-10-01

    Proton radiography is an important diagnostic tool for laser plasma experiments and for studying magnetized plasmas. We describe a new synthetic proton radiography diagnostic recently implemented into the FLASH code. FLASH is an open source, finite-volume Eulerian, spatially adaptive radiation hydrodynamics and magneto-hydrodynamics code that incorporates capabilities for a broad range of physical processes. Proton radiography is modeled through the use of the (relativistic) Lorentz force equation governing the motion of protons through 3D domains. Both instantaneous (one time step) and time-resolved (over many time steps) proton radiography can be simulated. The code module is also equipped with several different setup options (beam structure and detector screen placements) to reproduce a large variety of experimental proton radiography designs. FLASH's proton radiography diagnostic unit can be used either during runtime or in post-processing of simulation results. FLASH is publicly available at flash.uchicago.edu. U.S. DOE NNSA, U.S. DOE NNSA ASC, U.S. DOE Office of Science and NSF.

  4. Lateral radiography of the knee with single-leg standing

    Energy Technology Data Exchange (ETDEWEB)

    Ohmori, Kan; Sugawara, Tsuyoshi; Murakami, Katsuyoshi; Kirinai, Mikio; Fujiwara, Junichi; Oikawa, Takumi; Matsumura, Yutaka; Sugawara, Tsukasa [Iwate Medical Univ., Morioka (Japan). Hospital

    2002-07-01

    The purpose of this investigation was to accomplish reproducible radiography of single-leg standing lateral radiography of the knee by adjusting lateral rotation using a ruler to measure foot position. After preliminary assessment of three-dimensional CT of the knees of normal volunteers, the best adjustment of external rotation was estimated. A ruler was made for use in adjusting the angle of knee rotation by measuring foot rotation. Based on the foot rotation measured by this ruler, the positioning of radiography was adjusted to correct rotation. Rotation was estimated by the distance between the posterior edges of the lateral and medial femoral condyles. Fifteen-degree and 17.5-degree rotations were used for correction. Correction of rotation was 17 degrees on average. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate of lateral knee radiography. (author)

  5. Intercomparison of gamma scattering, gammatography, and radiography techniques for mild steel nonuniform corrosion detection

    Science.gov (United States)

    Priyada, P.; Margret, M.; Ramar, R.; Shivaramu, Menaka, M.; Thilagam, L.; Venkataraman, B.; Raj, Baldev

    2011-03-01

    This paper focuses on the mild steel (MS) corrosion detection and intercomparison of results obtained by gamma scattering, gammatography, and radiography techniques. The gamma scattering non-destructive evaluation (NDE) method utilizes scattered gamma radiation for the detection of corrosion, and the scattering experimental setup is an indigenously designed automated personal computer (PC) controlled scanning system consisting of computerized numerical control (CNC) controlled six-axis source detector system and four-axis job positioning system. The system has been successfully used to quantify the magnitude of corrosion and the thickness profile of a MS plate with nonuniform corrosion, and the results are correlated with those obtained from the conventional gammatography and radiography imaging measurements. A simple and straightforward reconstruction algorithm to reconstruct the densities of the objects under investigation and an unambiguous interpretation of the signal as a function of material density at any point of the thick object being inspected is described. In this simple and straightforward method the density of the target need not be known and only the knowledge of the target material's mass attenuation coefficients (composition) for the incident and scattered energies is enough to reconstruct the density of the each voxel of the specimen being studied. The Monte Carlo (MC) numerical simulation of the phenomena is done using the Monte Carlo N-Particle Transport Code (MCNP) and the quantitative estimates of the values of signal-to-noise ratio for different percentages of MS corrosion derived from these simulations are presented and the spectra are compared with the experimental data. The gammatography experiments are carried out using the same PC controlled scanning system in a narrow beam, good geometry setup, and the thickness loss is estimated from the measured transmitted intensity. Radiography of the MS plates is carried out using 160 kV x

  6. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients

    Directory of Open Access Journals (Sweden)

    Ali Vafaei

    2016-01-01

    Full Text Available Introduction: Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. Methods: In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. Results: 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67, were enrolled (77.6% male. Chest CT scan showed pulmonary contusion in 48 (31.6% patients, hemothorax in 29 (19.1%, and pneumothorax in 55 (36.2% cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96, 0.86 (95% CI: 0.78‒0.94, and 0.80 (95% CI: 0.736‒0.88, respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87 for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86 for hemothorax, and 0.58 (95% CI: 0.5‒0.67 for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02 and pulmonary contusion (p < 0.001. However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08. Conclusion: The results of the present study showed that ultrasonography is preferable to radiography in the initial

  7. Effective dose efficiency: an application-specific metric of quality and dose for digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Samei, Ehsan; Ranger, Nicole T; Dobbins, James T III; Ravin, Carl E, E-mail: samei@duke.edu [Carl E Ravin Advanced Imaging Laboratories, Department of Radiology (United States)

    2011-08-21

    The detective quantum efficiency (DQE) and the effective DQE (eDQE) are relevant metrics of image quality for digital radiography detectors and systems, respectively. The current study further extends the eDQE methodology to technique optimization using a new metric of the effective dose efficiency (eDE), reflecting both the image quality as well as the effective dose (ED) attributes of the imaging system. Using phantoms representing pediatric, adult and large adult body habitus, image quality measurements were made at 80, 100, 120 and 140 kVp using the standard eDQE protocol and exposures. ED was computed using Monte Carlo methods. The eDE was then computed as a ratio of image quality to ED for each of the phantom/spectral conditions. The eDQE and eDE results showed the same trends across tube potential with 80 kVp yielding the highest values and 120 kVp yielding the lowest. The eDE results for the pediatric phantom were markedly lower than the results for the adult phantom at spatial frequencies lower than 1.2-1.7 mm{sup -1}, primarily due to a correspondingly higher value of ED per entrance exposure. The relative performance for the adult and large adult phantoms was generally comparable but affected by kVps. The eDE results for the large adult configuration were lower than the eDE results for the adult phantom, across all spatial frequencies (120 and 140 kVp) and at spatial frequencies greater than 1.0 mm{sup -1} (80 and 100 kVp). Demonstrated for chest radiography, the eDE shows promise as an application-specific metric of imaging performance, reflective of body habitus and radiographic technique, with utility for radiography protocol assessment and optimization.

  8. Alternative procedure for the cold test for soybean seeds Procedimento alternativo para o teste de frio em semente de soja

    Directory of Open Access Journals (Sweden)

    Bruno Guilherme Torres Licursi Vieira

    2010-10-01

    . Uma maneira de conseguir isso é pela melhoria dos testes de vigor. O teste de frio tem sido empregado em sementes de milho, no entanto, tem sido usado também para sementes de algodão (Gossypium spp., soja (Glycine Max, feijão ((Phaseolus vulgaris e ervilha (Pisum sativum. Este estudo foi conduzido com objetivo de ajustar o procedimento do teste para determinar o vigor de semente de soja. Foram utilizados seis lotes comerciais de semente de soja, cultivar BRS 133. O potencial fisiológico dos lotes foi avaliado usando-se os testes de germinação em rolo de papel toalha, tipo germitest, e em caixa com areia, de emergência de plântulas em campo, de tetrazólio, de envelhecimento acelerado e de condutividade elétrica. Determinou-se também o teor de água das sementes. Para composição dos procedimentos do teste de frio foi utilizada temperatura de 10ºC, tempo de permanência no frio por cinco dias, e quatro procedimentos: caixa com terra, rolo de papel com terra, rolo de papel sem terra e metodologia alternativa, rolo de papel sem terra sob água refrigerada. O delineamento experimental utilizado foi inteiramente casualizado com oito repetições e as médias foram comparadas pelo teste de Tukey (p = 0,05. Para verificar a dependência entre o método alternativo e os demais usou-se o coeficiente de correlação linear simples. Os procedimentos para condução do teste de frio apresentaram coeficientes de variação muito próximos (CV com destaque para a metodologia do rolo de papel com terra e procedimento alternativo, em média, com 94% e 93% de plântulas normais e CV de 3,2% e 3,6% respectivamente. O procedimento alternativo teve resultado satisfatório para estimar vigor da semente de soja, produzindo resultados consistentes em comparação ao procedimento tradicional.

  9. Applications of Cosmic Ray Muon Radiography

    Science.gov (United States)

    Guardincerri, E.; Durham, J. M.; Morris, C. L.; Rowe, C. A.; Poulson, D. C.; Bacon, J. D.; Plaud-Ramos, K.; Morley, D. J.

    2015-12-01

    The Dome of Santa Maria del Fiore, Florence Cathedral, was built between 1420 and 1436 by architect Filippo Brunelleschi and it is now cracking under its own weight. Engineering efforts are underway to model the dome's structure and reinforce it against further deterioration. According to some scholars, Brunelleschi might have built reinforcement structures into the dome itself; however, the only confirmed known subsurface reinforcement is a chain of iron and stone around the dome's base. Tomography with cosmic ray muons is a non-destructive imaging method that can be used to image the interior of the wall and therefore ascertain the layout and status of any iron substructure in the dome. We will show the results from a muon tomography measurement of iron hidden in a mockup of the dome's wall performed at Los Alamos National Lab in 2015. The sensitivity of this technique, and the status of this project will be also discussed. At last, we will show results on muon attenuation radiography of larger shallow targets.

  10. Optical compensation device for chest film radiography

    Science.gov (United States)

    Gould, Robert G.; Hasegawa, Bruce H.; DeForest, Sherman E.; Schmidt, Gregory W.; Hier, Richard G.

    1990-07-01

    Although chest radiography is the most commonly performed radiographic examination and one of the most valuable and cost-effective studies in medicine it suffers from relatively high error rates in both missing pathology and false positive interpretations. Detectability of lung nodules and other structures in underpenetrated regions of the chest film can be improved by both exposure and optical compensation but current compensation systems require major capital cost or a significant change in normal clinical practice. A new optical compensation system called the " Intelligent X-Ray Illuminator" (IXI) automatically and virtually instantaneously generates a patient-specific optical unsharp mask that is projected directly on a radiograph. When a radiograph is placed on the IXI which looks much like a conventional viewbox it acquires a low-resolution electronic image of this film from which the film transmission is derived. The transmission information is inverted and blurred in an image processor to form an unsharp mask which is fed into a spatial light modulator (SLM) placed between a light source and the radiograph. The SLM tailors the viewbox luminance by decreasing illumination to underexposed (i. e. transmissive) areas of the radiograph presenting the observer with an optically unsharp-masked image. The IXI uses the original radiograph and will allow it to be viewed on demand with conventional (uniform illumination. Potentially the IXI could introduce the known beneficial aspects of optical unsharp masking into radiology at low capital

  11. Evaluation of Deblur Methods for Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Wood, William M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-03-31

    Radiography is used as a primary diagnostic for dynamic experiments, providing timeresolved radiographic measurements of areal mass density along a line of sight through the experiment. It is well known that the finite spot extent of the radiographic source, as well as scattering, are sources of blurring of the radiographic images. This blurring interferes with quantitative measurement of the areal mass density. In order to improve the quantitative utility of this diagnostic, it is necessary to deblur or “restore” the radiographs to recover the “true” areal mass density from a radiographic transmission measurement. Towards this end, I am evaluating three separate methods currently in use for deblurring radiographs. I begin by briefly describing the problems associated with image restoration, and outlining the three methods. Next, I illustrate how blurring affects the quantitative measurements using radiographs. I then present the results of the various deblur methods, evaluating each according to several criteria. After I have summarized the results of the evaluation, I give a detailed account of how the restoration process is actually implemented.

  12. Beam Characterization at the Neutron Radiography Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sarah Morgan; Jeffrey King

    2013-01-01

    The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

  13. Comparison of state dental radiography safety regulations.

    Science.gov (United States)

    McDaniel, Thomas F; Parashar, Vijay

    2015-01-01

    The aim of this study was to compare and provide an overview of state policies on occupational exposure, dosimetry, collimation, patient protection, and the use of portable handheld X-ray machines in dentistry. State government webpages containing radiation protection rules and regulations were scanned. The contents were compared against current federal regulations established by the Nuclear Regulatory Commission (NRC) and the US Food and Drug Administration (FDA). They were further evaluated in light of current recommendations from the National Council on Radiation Protection & Measurements (NCRP) and the American Dental Association (ADA). Most states' regulations mirror the exposure limits set forth by the NRC and FDA. Nonregulatory recommendations regarding use of dental radiography are periodically put forth by the NCRP and the ADA. State and federal agencies often follow recommendations from these scientific organizations when creating regulations. Clinicians must be aware of their state's radiation protection rules, as variations among states exist. In addition, recommendations published by organizations such as the NCRP and the ADA, while not legally binding, contribute significantly to the reduction of radiation risks for operators and patients alike.

  14. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2013-01-01

    Full Text Available Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS, four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360 were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC curve (Az were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively. The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631. Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.

  15. Psico-Oncologia e manejo de procedimentos invasivos em oncologia pediátrica: uma revisão de literatura

    Directory of Open Access Journals (Sweden)

    Costa Jr. Áderson L.

    1999-01-01

    Full Text Available Este texto descreve alguns tópicos de pesquisa em Psico-Oncologia Pediátrica, discutindo-se a necessidade da implementação de estudos de intervenção que investiguem, entre outros temas, o manejo de procedimentos médicos invasivos em Oncologia e o(s efeito(s das intervenções efetuadas, pelos profissionais de saúde, sobre o repertório de comportamentos da criança. Descreve-se e analisa-se, criticamente, as principais medidas tomadas em estudos que avaliam o comportamento de crianças submetidas a procedimentos médicos invasivos, apontando-se a pesquisa comportamental como útil à geração de informações acerca da relação funcional entre o contexto de procedimentos invasivos e os comportamentos da criança.

  16. Padronização da anestesia em suínos para procedimentos cirúrgicos cardiovasculares experimentais

    OpenAIRE

    Geovanini, Glaucylara Reis; Pinna, Fábio R.; Prado, Flávio A. P.; Tamaki, Wagner Tetsuji; Marques, Euclides

    2008-01-01

    JUSTIFICATIVA E OBJETIVO: Embora sejam os cães os animais mais utilizados em Cirurgia Experimental, nota-se crescente utilização de ovinos, bovinos e suínos como modelos para experimentação científica. Assim, faz-se necessário maior aprendizado de seu tratamento e padronizações básicas para os procedimentos cirúrgicos mais complexos em suínos. O objetivo foi avaliar a sedação e analgesia, obtidas pela injeção intramuscular de midazolam e cetamina e anestesia local com lidocaína a 2% sem vasoc...

  17. Water Migration and Swelling in Bentonite Quantified using Neutron Radiography

    Science.gov (United States)

    Vial, A.; DiStefano, V. H.; Perfect, E.; Hale, R. E.; Anovitz, L. M.; McFarlane, J.

    2016-12-01

    Permanent disposal of radioactive waste remains a critical challenge for the nation's energy future. All disposal system concepts include interfaces between engineered systems and natural materials requiring extensive characterization. Bentonite is often used to buffer subsurface disposal systems from geologic media containing ground water. Bentonite characterization experiments were carried out using the CG-1D neutron imaging beam line at Oak Ridge National Laboratory. Dry bentonite was packed into vertically-oriented aluminum cylinders. Water was ponded on the top surface of each packed cylinder. Images were acquired at 2 min intervals using dynamic neutron radiography. The detector consisted of stacked neutron sensitive microchannel plates above a quad Timepix readout with a 28 x 28 mm2 field of view. The spatial resolution of the detector was 55 μm. Raw neutron radiographs were imported into ImageJ and normalized with respect to the initial completely dry state. The wetting process was 1-dimensional, and vertical intensity profiles were computed by averaging pixel rows. The vertical distance between the clay-water interface and the wetting front could then be determined as a function of time. Depth of water infiltration increased linearly with the square root of time, yielding a sorptivity value of 0.75 (± 0.070) mm/min0.5. Swelling occurred in the form of upward movement of clay particles into the ponded water over time. The resulting low density assemblage was discernable by normalizing the raw profiles with respect to the intensity profile immediately after ponding. The packed clay-water interface was clearly visible in the normalized profiles, and swelling was quantified as the height of the low density assemblage above the original interface. Swelling occurred as a linear function of time, at a rate of 0.054 (± 0.020) mm/min. Further experiments of this type are planned under variable temperature and pressure regimes applicable to subsurface

  18. Detecting osteoporosis in elderly women with panoramic radiography technique

    Directory of Open Access Journals (Sweden)

    Barunawaty Yunus

    2016-12-01

    Full Text Available Osteoporosis is a systemic disease which characterized by a reduction in bone mass with deterioration microarchitecture of bone and degradation of bone tissue which can raise loss of bone. Osteoporosis is a problem related to the aging process. Osteoporosis process actually begin at the age 40-50 years. At this age, men and women will experience shrinkage process of bone mass. in women, this process faster after menopause and is more common in women than men. The technique can be used to detect osteoporosis by performing panoramic radiographic examination techniques. Panoramic radiography is a technique for generating photo of facial structures, including the maxillary bone, mandibular and other support structures. To detect the presence of osteoporosis in elderly women using Panoramic Radiography Techniques. The subjects of this study is image results of a panoramic radiography with vulnerable women aged 50-70> obtained from the Hospital Radiology section of Unhas, Mental Index measurement is then performed on image results of the panoramic radiographs. Overall regardless of age , the prevalence of osteoporosis reached 10 % per 100 population . ( P > 0.05. In detecting osteoporosis in elderly women, panoramic radiography can be applied. The index used is Mental Index, an index of panoramic radiography has been developed to detect osteoporosis.

  19. Application of digital radiography in the analysis of cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Oiveira, Davi F.; Calza, Cristiane; Rocha, Henrique S.; Nascimento, Joseilson R.; Lopes, Ricardo T., E-mail: davi@lin.ufrj.br, E-mail: ccalza@lin.ufrj.br, E-mail: henrique@lin.ufrj.br, E-mail: joseilson@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear

    2013-07-01

    The scientific examination of artworks has gained increasing interest in the last years, allowing the characterization of materials and techniques employed by the artists. This analysis can be extremely valuable to conservation and restoration treatments. However, the fact that every artworks is a unique piece emphasizes the necessity of working with non-destructive techniques. Although radiography has been used in the technical examination of museum objects for many decades, digital radiography is rapidly becoming a preferred modality for this essential tool in the advanced examination of works of art. The ability to electronically combine images from the large painting into a single composite image file was extremely valuable and results in higher quality images than those achieved with conventional radiography. These images can be also processed and improved using adequate software. Additional advantages of digital radiography include the possibility of an almost immediate analysis of the results, use of an only recording film and absence of chemical processing. Radiographic imaging can be applied to the analysis of virtually all media including paintings, sculptures, woodworks, engravings, etc. This paper reports some case studies of the use of digital radiography in the study of paintings and sculptures, showing the feasibility and advantages of this technique for this kind of purpose. The radiographic images revealed the conservation state of the analyzed objects and various details of its execution in order to assist recently restoration processes. (author)

  20. A benchmark for comparison of dental radiography analysis algorithms.

    Science.gov (United States)

    Wang, Ching-Wei; Huang, Cheng-Ta; Lee, Jia-Hong; Li, Chung-Hsing; Chang, Sheng-Wei; Siao, Ming-Jhih; Lai, Tat-Ming; Ibragimov, Bulat; Vrtovec, Tomaž; Ronneberger, Olaf; Fischer, Philipp; Cootes, Tim F; Lindner, Claudia

    2016-07-01

    Dental radiography plays an important role in clinical diagnosis, treatment and surgery. In recent years, efforts have been made on developing computerized dental X-ray image analysis systems for clinical usages. A novel framework for objective evaluation of automatic dental radiography analysis algorithms has been established under the auspices of the IEEE International Symposium on Biomedical Imaging 2015 Bitewing Radiography Caries Detection Challenge and Cephalometric X-ray Image Analysis Challenge. In this article, we present the datasets, methods and results of the challenge and lay down the principles for future uses of this benchmark. The main contributions of the challenge include the creation of the dental anatomy data repository of bitewing radiographs, the creation of the anatomical abnormality classification data repository of cephalometric radiographs, and the definition of objective quantitative evaluation for comparison and ranking of the algorithms. With this benchmark, seven automatic methods for analysing cephalometric X-ray image and two automatic methods for detecting bitewing radiography caries have been compared, and detailed quantitative evaluation results are presented in this paper. Based on the quantitative evaluation results, we believe automatic dental radiography analysis is still a challenging and unsolved problem. The datasets and the evaluation software will be made available to the research community, further encouraging future developments in this field. (http://www-o.ntust.edu.tw/~cweiwang/ISBI2015/). Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  2. Pediatric digital radiography summit overview: state of confusion

    Energy Technology Data Exchange (ETDEWEB)

    Don, Steven [Washington University School of Medicine, St. Louis Children' s Hospital, Mallinckrodt Institute of Radiology, St. Louis, MO (United States)

    2011-05-15

    On Feb. 4, 2010, the Alliance for Radiation Safety in Pediatric Radiology held a Pediatric Digital Radiography Summit. The goal was for radiologists, radiologic technologists, medical physicists, and vendor representatives, including engineers, medical physicists and education specialists, to discuss the challenges to achieving the ALARA (as low as reasonably achievable) principle in pediatric digital radiography and to lay the groundwork for overcoming these obstacles. This article focuses on the state of confusion that exists for radiologists and radiologic technologists who use digital radiography equipment. Radiologists might have a difficult time accepting lower dose (noisy images), and radiologic technologists might respond by increasing patient exposures, which results in excessive patient doses. For reporting exposures, vendors have a history of using proprietary terms that confuse users. In addition, technical parameters cannot be easily exported for quality assurance, and there is no national standard for digital radiography. Presentations in this minisymposium focus on suggestions for the cooperative development of new technical standards, education and training to improve the quality of digital radiography in pediatric patients and promote radiation protection for children. (orig.)

  3. Radiography of the mandible prior to endosseous implant treatment. Localization of the mandibular canal and assessment of trabecular bone

    Energy Technology Data Exchange (ETDEWEB)

    Lindh, C.

    1996-03-01

    Mandibular autopsy specimens were examined with different radiographic techniques in order to evaluate the visibility of the mandibular canal and the measurement accuracy of distances related to the mandibular canal. Hypocycloidal, spiral and computed tomography (CT) were superior to periapical and panoramic radiography in visualizing the mandibular canal. The tomographic techniques were more accurate when measurements of distances related to the mandibular canal were performed. No difference in measurement accuracy was found between the tomographic techniques. Concerning visibility of the mandibular canal, interobserver agreement was lowest for periapical radiography and highest for CT. Intraobserver agreement was moderate or good for all techniques. A high interobserver variation was found for measurability of distances related to the mandibular canal. The trabecular bone tissue in mandibular autopsy specimens was studied concerning different characteristics. A classification system to be used prior to implant treatment, based on the trabecular pattern in periapical radiographs, was proposed. 74 refs.

  4. Pencil beam proton radiography using a multilayer ionization chamber

    Science.gov (United States)

    Farace, Paolo; Righetto, Roberto; Meijers, Arturs

    2016-06-01

    A pencil beam proton radiography (PR) method, using a commercial multilayer ionization chamber (MLIC) integrated with a treatment planning system (TPS) was developed. A Giraffe (IBA Dosimetry) MLIC (±0.5 mm accuracy) was used to obtain pencil beam PR by delivering spots uniformly positioned at a 5.0 mm distance in a 9  ×  9 square of spots. PRs of an electron-density (with tissue-equivalent inserts) phantom and a head phantom were acquired. The integral depth dose (IDD) curves of the delivered spots were computed by the TPS in a volume of water simulating the MLIC, and virtually added to the CT at the exit side of the phantoms. For each spot, measured and calculated IDD were overlapped in order to compute a map of range errors. On the head-phantom, the maximum dose from PR acquisition was estimated. Additionally, on the head phantom the impact on the range errors map was estimated in case of a 1 mm position misalignment. In the electron-density phantom, range errors were within 1 mm in the soft-tissue rods, but greater in the dense-rod. In the head-phantom the range errors were  -0.9  ±  2.7 mm on the whole map and within 1 mm in the brain area. On both phantoms greater errors were observed at inhomogeneity interfaces, due to sensitivity to small misalignment, and inaccurate TPS dose computation. The effect of the 1 mm misalignment was clearly visible on the range error map and produced an increased spread of range errors (-1.0  ±  3.8 mm on the whole map). The dose to the patient for such PR acquisitions would be acceptable as the maximum dose to the head phantom was  <2cGyE. By the described 2D method, allowing to discriminate misalignments, range verification can be performed in selected areas to implement an in vivo quality assurance program.

  5. 75 FR 57080 - In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order...

    Science.gov (United States)

    2010-09-17

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order... which authorizes the possession, use, and operation of the Aerotest Radiography and Research Reactor...

  6. An atlas-based organ dose estimator for tomosynthesis and radiography

    Science.gov (United States)

    Hoye, Jocelyn; Zhang, Yakun; Agasthya, Greeshma; Sturgeon, Greg; Kapadia, Anuj; Segars, W. Paul; Samei, Ehsan

    2017-03-01

    The purpose of this study was to provide patient-specific organ dose estimation based on an atlas of human models for twenty tomosynthesis and radiography protocols. The study utilized a library of 54 adult computational phantoms (age: 18-78 years, weight 52-117 kg) and a validated Monte-Carlo simulation (PENELOPE) of a tomosynthesis and radiography system to estimate organ dose. Positioning of patient anatomy was based on radiographic positioning handbooks. The field of view for each exam was calculated to include relevant organs per protocol. Through simulations, the energy deposited in each organ was binned to estimate normalized organ doses into a reference database. The database can be used as the basis to devise a dose calculator to predict patient-specific organ dose values based on kVp, mAs, exposure in air, and patient habitus for a given protocol. As an example of the utility of this tool, dose to an organ was studied as a function of average patient thickness in the field of view for a given exam and as a function of Body Mass Index (BMI). For tomosynthesis, organ doses can also be studied as a function of x-ray tube position. This work developed comprehensive information for organ dose dependencies across tomosynthesis and radiography. There was a general exponential decrease dependency with increasing patient size that is highly protocol dependent. There was a wide range of variability in organ dose across the patient population, which needs to be incorporated in the metrology of organ dose.

  7. A Method to Prevent Occipitocervical Joint Violation Using Plain Radiography During Percutaneous Anterior Transarticular Screw Fixation.

    Science.gov (United States)

    Jin, Hai-Ming; Xu, Dao-Liang; Xuan, Jun; Chen, Jiao-Xiang; Goswami, Amit; Chen, Xi-Bang; Wu, Ai-Min; Chi, Yong-Long; Wang, Xiang-Yang

    2016-09-01

    A prospective study of anterior transarticular screw (ATS) fixation patients. To develop a method to determine screw tip position through plain radiography after percutaneous ATS fixation to prevent occipitocervical joint (OCJ) violation. No studies using plain radiography to prevent OCJ violation during percutaneous ATS fixation have been performed. In total, 34 subjects (with 68 screws) who had undergone percutaneous ATS fixation were enrolled. To evaluate the screw tip location in relation to the C1 lateral mass (LM), the screw tip positions were graded 1, 2, or 3 on anteroposterior (AP) radiographs, and I, II, or III on lateral radiographs. OCJ violation was analyzed by postoperative computed tomography (CT). Screws with tips located lower (tip I) in the LM did not result in OCJ violation. Only one tip in the tip 3 position showed OCJ perforation, and this screw was also located in tip III. Screw perforation rates of tip 1-tip II, tip 1-tip III, and tip 2-tip III were the highest (100%), followed by tip 2-tip II (10.5%) and tip3-tip III (10%). This study provides insights into OCJ violation during percutaneous ATS fixation. According to AP radiography, a percutaneous ATS with the screw tip located in the lateral part of the LM resulted in a lower rate of OCJ perforation, whereas screws located in the medial LM resulted in the highest rate of perforation. Percutaneous ATS with the screw tip located in the neutral part of the LM should ensure that the screw tip is below the upper part of the LM, preventing OCJ violation. These findings may help surgeons assess screw positioning both during and after the operation. 3.

  8. Clinical applications of extra-oral periapical radiography

    Directory of Open Access Journals (Sweden)

    Sujatha S Reddy

    2012-01-01

    Full Text Available Radiographic examination forms an integral part of clinical dentistry, with some form of radiographs necessary on the majority of patients. Intra-oral periapical (IOPA radiographs form the backbone of imaging for diagnosis and follow-up of various dento-facial pathologies. However, certain patient populations are unable to tolerate intra-oral films/sensors due to various reasons. A not-so recent development called extra-oral periapical (EOPA radiography may be a useful adjuvant to such a situation, at least in the near future. It is essentially a technique where the film is placed extra-orally overlying the tooth of interest. The following manuscript is an attempt to throw light on this technique and the impact it may have on various disciplines of dental practices. The advantages and disadvantages of EOPA radiography and it′s comparison to IOPA radiography has been discussed.

  9. Study of pipe thickness loss using a neutron radiography method

    Science.gov (United States)

    Mohamed, Abdul Aziz; Wahab, Aliff Amiru Bin; Yazid, Hafizal B.; Ahmad, Megat Harun Al Rashid B. Megat; Jamro, Rafhayudi B.; Azman, Azraf B.; Zin, Muhamad Rawi Md; Idris, Faridah Mohamad

    2014-02-01

    The purpose of this preliminary work is to study for thickness changes in objects using neutron radiography. In doing the project, the technique for the radiography was studied. The experiment was done at NUR-2 facility at TRIGA research reactor in Malaysian Nuclear Agency, Malaysia. Test samples of varying materials were used in this project. The samples were radiographed using direct technique. Radiographic images were recorded using Nitrocellulose film. The films obtained were digitized to processed and analyzed. Digital processing is done on the images using software Isee!. The images were processed to produce better image for analysis. The thickness changes in the image were measured to be compared with real thickness of the objects. From the data collected, percentages difference between measured and real thickness are below than 2%. This is considerably very low variation from original values. Therefore, verifying the neutron radiography technique used in this project.

  10. Gamma radiography of refractory-lined vessels and components

    Energy Technology Data Exchange (ETDEWEB)

    Lapinski, N. P.

    1978-08-01

    Materials used in coal-conversion systems are exposed to high pressure, high temperature, corrosive and erosive gases, and liquids containing particulate matter. These severe environments necessitate an assessment of the integrity of components to prevent premature failures. Gamma radiography was evaluated as a viable technique for testing such components in the laboratory or after operation in situ. Penetrameters (image-quality indicators) were developed for refractory-lined vessels and transfer lines, and exposure times for various combinations of refractory-steel thicknesses were determined. Radiography with /sup 60/Co was performed on gasifier vessels, combustor vessels, and critical transfer lines in existing pilot plants using the experience gained through laboratory experiments. The results show that gamma radiography is a practical and effective method to detect critical conditions in coal-conversion system components. 18 figures, 3 tables.

  11. Neutron radiography (NRAD) reactor 64-element core upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately ±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  12. Wind Turbine Blade Nondestructive Testing with a Transportable Radiography System

    Directory of Open Access Journals (Sweden)

    J. G. Fantidis

    2011-01-01

    Full Text Available Wind turbines are becoming widely used as they are an environmentally friendly way for energy production without emissions; however, they are exposed to a corrosive environment. In addition, as wind turbines typically are the tallest structures in the surrounding area of a wind farm, it is expected that they will attract direct lightning strikes several times during their operating life. The purpose of this paper is to show that the radiography with a transportable unit is a solution to find defects in the wind turbine blade and reduce the cost of inspection. A transportable neutron radiography system, incorporating an Sb–Be source, has been simulated using the MCNPX code. The simulated system has a wide range of radiography parameters.

  13. Correction parameters in conventional dental radiography for dental implant

    Directory of Open Access Journals (Sweden)

    Barunawaty Yunus

    2009-12-01

    Full Text Available Background: Radiographic imaging as a supportive diagnostic tool is the essential component in treatment planning for dental implant. It help dentist to access target area of implant due to recommendation of many inventions in making radiographic imaging previously. Along with the progress of science and technology, the increasing demand of easier and simpler treatment method, a modern radiographic diagnostic for dental implant is needed. In fact, Makassar, especially in Faculty of Dentistry Hasanuddin University, has only a conventional dental radiography. Researcher wants to optimize the equipment that is used to obtain parameters of the jaw that has been corrected to get accurate dental implant. Purpose: This study aimed to see the difference of radiographic imaging of dental implant size which is going to be placed in patient before and after correction. Method: The type of research is analytical observational with cross sectional design. Sampling method is non random sampling. The amount of samples is 30 people, male and female, aged 20–50 years old. The correction value is evaluated from the parameter result of width, height, and thick of the jaw that were corrected with a metal ball by using conventional dental radiography to see the accuracy. Data is analyzed using SPSS 14 for Windows program with T-test analysis. Result: The result that is obtained by T-Test analysis results with significant value which p<0.05 in the width and height of panoramic radiography technique, the width and height of periapical radiography technique, and the thick of occlusal radiography technique before and after correction. Conclusion: It can be concluded that there is a significant difference before and after the results of panoramic, periapical, and occlusal radiography is corrected.

  14. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND... Records of the specific license for industrial radiography. Each licensee shall maintain a copy of its...

  15. 10 CFR 34.20 - Performance requirements for industrial radiography equipment.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Performance requirements for industrial radiography equipment. 34.20 Section 34.20 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND... requirements for industrial radiography equipment. Equipment used in industrial radiographic operations must...

  16. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION... Radiation Safety Officer for industrial radiography. The RSO shall ensure that radiation safety activities...

  17. Sacroiliitis in ankylosing spondylitis: a comparison of radiography and scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Goo; Kang, Heung Sik; Ahn, Joong Mo; Cha, Sang Hoon; Chung, June Key; Song, Yeong Wook [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1991-05-15

    To evaluate the correlation between plain radiography and bone scintigraphy in the diagnosis of sacroiliitis, we analyzed 50 sacroiliac joints of 25 patients diagnosed as ankylosing spondylitis. The sacroiliac-sacral (SIS) ratio significantly increases in patients with sacroiliitis of Grade I, II, III and was normal in completely ankylosed sacroiliac joints (Grade IV). However, there was no correlation between the degree of increase of SIS ratio and that of the radiographic changes in Grade I, II, III groups. Bone scintigraphy might be useful in the early detection of sacroiliitis. but plain radiography is more valuable in evaluating progression.

  18. Proton radiography, nuclear cross sections and multiple Coulomb scattering

    Energy Technology Data Exchange (ETDEWEB)

    Sjue, Sky K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-04

    The principles behind proton radiography including multiple Coulomb scattering are discussed for a purely imaginary square well nucleus in the eikonal approximation. It is found that a very crude model can reproduce the angular dependence of the cross sections measured at 24 GeV/c. The largest differences are ~3% for the 4.56 mrad data, and ~4% for the 6.68 mrad data. The prospect of understanding how to model deterministically high-energy proton radiography over a very large range of energies is promising, but it should be tested more thoroughly.

  19. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Madhurima, E-mail: madhurimashrm88@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Sandhu, Manavjit Singh, E-mail: manavjitsandhu@yahoo.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gorsi, Ujjwal, E-mail: ujjwalgorsi@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gupta, Dheeraj, E-mail: dheeraj1910@gmail.com [Department of Pulmonary Medicine, PGIMER, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India)

    2015-09-15

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  20. Procedimento estatístico para validação de escalas diagramáticas na quantificação de doenças

    Directory of Open Access Journals (Sweden)

    Reginaldo Gonçalves Máfia

    2011-04-01

    Full Text Available Na validação de escalas diagramáticas de doenças é comum utilizar a regressão linear simples para testar a identidade entre dados estimados e valores reais de severidade de doença. Nestes casos, após ajustar a regressão linear, as hipóteses H01: β0 = 0 e H02: β1 = 1 ão testadas, mas não de forma simultânea, ou seja, se β0 = 0 ao mesmo tempo em que β1 = 1, ou, se β1 = 1 ao mesmo tempo em que β0 = 0. O objetivo deste trabalho foi propor um novo procedimento estatístico para validação de escalas diagramáticas, denominado L&O. Este procedimento resulta da combinação do teste F, modificado por Graybill (1976, teste t para o erro médio e análises do coeficiente de correlação linear. Este procedimento foi aplicado para testar a identidade entre valores estimados e valores reais de severidade da doença causada por Quambalaria eucalypti em eucalipto. Os resultados mostraram que o procedimento estatístico foi eficiente, não subjetivo e permitiu também testar a identidade entre quaisquer dois vetores ou grupos de dados quantitativos.

  1. Elaboração de uma hipermídia educacional para o ensino do procedimento de medida da pressão arterial

    Directory of Open Access Journals (Sweden)

    Debora Cristina Alavarce

    2011-08-01

    Full Text Available A medida da pressão arterial é um procedimento imprescindível na avaliação do sistema cardiovascular. O ambiente digital de aprendizagem tem-se constituído em uma poderosa ferramenta do processo de ensino aprendizagem, pois acrescenta significado e concretude aos conteúdos que precisam ser aprendidos, podendo ser útil para o ensino deste procedimento. O objetivo deste trabalho foi construir uma hipermídia educacional para o ensino da técnica de medida da pressão arterial e descrever as etapas do processo de construção. O referencial pedagógico adotado foi o de Robert Gagné; para a construção, segue-se o modelo proposto por Price. O produto final apresenta vídeos, fotos, animações e simulações demonstrando e ensinando a realização do procedimento. Embora a construção da hipermídia tenha sido complexa, sua utilização pode incrementar positivamente o ensino de procedimentos de enfermagem.

  2. Measuring microfocal spots using digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Fry, David A [Los Alamos National Laboratory; Ewert, Uwe [BAM

    2009-01-01

    Measurement of microfocus spot size can be important for several reasons: (1) Quality assurance during manufacture of microfocus tubes; (2) Tracking performance and stability of microfocus tubes; (3) Determining magnification is especially important for digital radiography where the native spatial resolution of the digital system is not adequate for the application; and (4) Knowledge of unsharpness from the focal spot alone. The European Standard EN 12543-5 is based on a simple geometrical method of calculating focal spot size from unsharpness of high magnification film radiographs. The following equations are used for the focal spot size measurement: By similar triangles the following equations are presupposed: f/a = U/b and M = (a+b)/a. These equations can be combined to yield the well known expression: U = f(M - 1). Solving for f, f = U/(M-1). Therefore, the focal spot size, f, can be calculated by measuring the radiographic unsharpness and magnification of a known object. This is the basis for these tests. The European standard actually uses one-half of the unsharpness (which are then added together) from both sides of the object to avoid additional unsharpness contributions due to edge transmission unsharpness of the round test object (the outside of the object is measured). So the equation becomes f = (1/2 U{sub 1} + 1/2 U{sub 2})/(M-1). In practice 1/2 U is measured from the 50% to the 90% signal points on the transition profile from ''black'' to ''white,'' (positive image) or attenuated to unattenuated portion of the image. The 50% to 90% points are chosen as a best fit to an assumed Gaussian radiation distribution from the focal spot and to avoid edge transmission effects. 1/2 U{sub 1} + 1/2 U{sub 2} corresponds about to the full width at half height of a Gaussian focal spot. A highly absorbing material (Tungsten, Tungsten Alloy, or Platinum) is used for the object. Either wires or a sphere are used as the object to

  3. Gastroplastia vertical com desvio jejunoileal: novo procedimento técnico Vertical gastroplasty with jejunoileal bypass: new technical procedure

    Directory of Open Access Journals (Sweden)

    Bruno Zilberstein

    2011-09-01

    Full Text Available INTRODUÇÃO: A gastroplastia vertical é procedimento técnico cada vez mais utilizado no tratamento cirúrgico da obesidade mórbida, sendo empregado isoladamente ou como tempo cirúrgico do duodenal switch ou da bipartição intestinal (técnica de Santoro. Quando empregada isoladamente tem apenas caráter restritivo. MÉTODO: É proposta a associação do desvio jejunoileal à gastroplastia vertical, no sentido de conferir um componente metabólico ao procedimento e eventualmente potencializá-lo a médio e longo prazos. Foram operados oito pacientes com obesidade mórbida após a retirada da banda gástrica ajustável ou como procedimento primário associado à gastroplastia vertical e desvio jejunoileal através de anastomose laterolateral entre o jejuno a 80 cm do ângulo dudeno jejunal e o íleo a 120 cm da válvula ileocecal, por videolaparoscopia. RESULTADOS: Os pacientes evoluíram sem qualquer intercorrência tanto no trans como no pós-operatório imediato, e nos meses que se seguiram. A evolução do IMC médio, mostrou redução expressiva indo de 39,57 kg/m² para 28 kg/m². Nenhum paciente referiu diarréia ou qualquer quadro disabsortivo no período estudado. CONCLUSÃO: Pode-se oferecer nova opção terapêutica, com ação restritiva e metabólica, na qual não existem os inconvenientes do desvio do trânsito duodenal com todas suas consequências.INTRODUCTION: Vertical gastroplasty is increasingly used in the surgical treatment of morbid obesity, being used alone or as part of the duodenal switch surgery or even in intestinal bipartition (Santoro technique. When used alone has only a restrictive character. METHOD: Is proposed association of jejunoileal bypass to vertical gastroplasty, in order to give a metabolic component to the procedure and eventually empower it to medium and long term. Eight morbidly obese patients were operated after removal of adjustable gastric band or as a primary procedure associated to vertical

  4. Comparative assessment of periapical radiography and CBCT imaging for radiodiagnostics in the posterior maxilla.

    Science.gov (United States)

    Shahbazian, Maryam; Vandewoude, Charlotte; Wyatt, Jan; Jacobs, Reinhilde

    2015-01-01

    Close proximity of the maxillary roots and the sinus floor makes a dental disease a probable cause of maxillary sinusitis. The aim of this study was to evaluate the ability of periapical radiography and cone beam computed tomography in defining the topographic relationship of maxillary teeth to the sinus floor and detecting apical periodontitis and other odontogenic causes of the maxillary sinusitis. Out of 145 dental records from subjects (mean age 52 years, range 20-75 years; 89 females) referred to the Oral Imaging Centre, KU Leuven, periapical and CBCT images of the posterior maxilla were selected for further analysis. Anatomical relationship of maxillary teeth to the sinus floor, apical periodontitis and other etiological causes of soft tissue thickening were assessed with both imaging modalities. The results of this study demonstrated that periapical radiographs are not adequate in observing the anatomical relationship between maxillary molars and the sinus floor. CBCT showed an intimate relationship of 1st and 2nd molar with the maxillary sinus in 50 and 45% of the cases, respectively. Periapical radiography could only spot approximately 40% of apical periodontitis on posterior maxillary teeth and 3% of all apical infections extending to the sinus, seen on CBCT.

  5. [Stature estimation of teenagers by limb long bones with computerized radiography].

    Science.gov (United States)

    Zheng, Tao; Huang, Yun; Zhang, Jian-Bo; Zhao, Huan; Wang, Yu-Zhuo; Shu, Yong-Kang; Deng, Zhen-Hua

    2011-06-01

    Relative parameters of upper limb bones, tibia and fibula were measured with computed radiography and used to establish the mathematical models for stature estimation of teenagers (from 14 to 18 years old) of Han population in Sichuan Province. The upper limb bones, tibia and fibula of 194 subjects were taken computerized radiography on normal position and were measured the lengths between relative landmarks. The body height of each subject was recorded. Linear regression equations for stature estimation between body height and the lengths of upper limb bones, tibia and fibula were established. Forty-two single linear regression equations and 4 multiple regression equations were obtained. The coefficients of correlation(r) were 0.689-0.917 and the standard errors of estimate(SE) were between 3.075 and 5.485 cm. All of the equations were statistically tested and diagnosed with good applicability. These equations could be used to estimate the body height of Sichuan Han population aged from 14 to 18. The lengths of the upper limb bones, tibia and fibula measured on the CR films could be useful to stature estimation of the adolescence and the forensic personal identification.

  6. Modifications of the thorax radiography after postoperative irradiation in mammary carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Scheier, M.; Rhomberg, W.; Schelling, F.

    1987-02-01

    The radiogenic modifications of the thorax radiography were evaluated in 100 patients irradiated postoperatively for mammary carcinoma between January, 1980 and March, 1983. No adjuvant chemotherapy was given. A telecobalt unit was used for the irradiations. A computer-assisted planning (Evados) was applied in order to obtain an individual optimization especially for the fields situated at the thoracic walls. The average focal doses to the thoracic wall and the regional lymph nodes were between 50 and 52 Gy. Taking into consideration all modifications visualized by radiography, 65% of patients had subacute radiogenic reactions in the lungs, especially in the apex fields. In general the modifications had no clinical importance. Only seven patients presented more severe forms of pneumonitis with clinical symptoms. Fibroses were developed only in the apex fields; infraclavicular infiltrations were seen only in exceptional cases. There were no costal necroses, essential pleural reactions, or radiogenic enlargements of the heart shadow. The rate of pulmonary reactions with clinical symptoms is reduced as compared with former techniques, e.g. opposing tangential fields. The knowledge of anamnesis and typical radiographic modifications should help to avoid problems of differentiation between apex reactions and tuberculosis.

  7. Sobre as bases dos procedimentos investigativos em psicanálise On the basis of investigation procedures in psychoanalysis

    Directory of Open Access Journals (Sweden)

    Anna Carolina Lo Bianco

    2003-12-01

    Full Text Available O presente trabalho examina as bases da pesquisa psicanalítica. Parte das marcas deixadas nas investigações psicanalíticas pelos procedimentos científicos de disciplinas como a neurologia e a neurofisiologia no século XIX. Em seguida, acompanha o surgimento de um novo objeto, o sujeito do inconsciente, o qual, ainda que requeira operações que mantenham o rigor e a precisão característicos do pensamento científico, implica formas de investigação mais apropriadas ao campo recém-constituído. Por fim, conclui que, ao contrário de emular os procedimentos das ciências naturais, a pesquisa em psicanálise tem de reconhecer a especificidade de seu objeto, pois este só se deixa circunscrever em análise, na qual analista e analisante estão implicados nas próprias produções inconscientes sob investigação. Essa é a particularidade da nova forma de saber que marca de modo indelével o pensamento do século XX em diante.The work examines the basis of psychoanalytical research. It begins by examining the influence of scientific procedures, used by neurology and neurophysiology in the nineteenth century, on psychoanalysis. It then observes the discovery of a new subject matter of research the unconscious. The latter following the rules of rigorous and precise scientific thought still implies the need for new, adequate forms of investigation for the recently forged field of research. As a conclusion it states that rather than imitating the natural sciences procedures, psychoanalytical research needs to recognise the specificity of its subject matter. Such subject matter can only be apprehended during the analytic session, where analyst and analysand are involved in the very unconscious productions under investigation. This constitutes the particular, new kind of knowledge that so much has influenced the twentieth century thought and beyond.

  8. A model-based radiography restoration method based on simple scatter-degradation scheme for improving image visibility

    Science.gov (United States)

    Kim, K.; Kang, S.; Cho, H.; Kang, W.; Seo, C.; Park, C.; Lee, D.; Lim, H.; Lee, H.; Kim, G.; Park, S.; Park, J.; Kim, W.; Jeon, D.; Woo, T.; Oh, J.

    2018-02-01

    In conventional planar radiography, image visibility is often limited mainly due to the superimposition of the object structure under investigation and the artifacts caused by scattered x-rays and noise. Several methods, including computed tomography (CT) as a multiplanar imaging modality, air-gap and grid techniques for the reduction of scatters, phase-contrast imaging as another image-contrast modality, etc., have extensively been investigated in attempt to overcome these difficulties. However, those methods typically require higher x-ray doses or special equipment. In this work, as another approach, we propose a new model-based radiography restoration method based on simple scatter-degradation scheme where the intensity of scattered x-rays and the transmission function of a given object are estimated from a single x-ray image to restore the original degraded image. We implemented the proposed algorithm and performed an experiment to demonstrate its viability. Our results indicate that the degradation of image characteristics by scattered x-rays and noise was effectively recovered by using the proposed method, which improves the image visibility in radiography considerably.

  9. The influence of the X-ray spectrum at compact bone-titanium interfaces in digital dental radiography.

    Science.gov (United States)

    Nicopoulou-Karayianni, K; Koligliatis, T; Donta-Bakogianni, C; Karayiannis, A

    2006-11-01

    To determine the optimum X-ray spectrum in digital dental radiography once the dose around an implant and the diagnostic usefulness of the image are taken into account. A Monte Carlo code (MCNP4B) was employed for computing the dose distribution across the bone-titanium interface. The X-ray spectra used were those met in digital dental radiography; 50-70 kVp, 2 mm Al total filtration, 5 kVp increment. The variation of the ratio of dose with as opposed to without implant against depth reaches maximum values at the bone-implant interface that vary between 2.9 and 3.2. For the same number of photon histories followed, the higher the tube potential setting, the greater the dose both in contact and inside the implant. In digital dental radiography, a 60-65 kVp spectrum accompanied by the known 30% reduction in mAs leads to lower dose to the patient for a diagnostically useful image.

  10. Assessment of panoramic radiography as a national oral examination tool: review of the literature

    Science.gov (United States)

    2011-01-01

    Purpose The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. Materials and Methods This report was carried out by review of the literatures. Results Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Conclusion Panoramic radiography will improve the efficacy of dental examination in national oral examination. However, more studies are required to evaluate the benefit, financial cost, and operation time and also to make selection criteria and quality management program. PMID:21977466

  11. Assessment of panoramic radiography as a national oral examination tool: review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2011-03-15

    The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. This report was carried out by review of the literatures. Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Panoramic radiography will improve the efficacy of dental examination in national oral examination. However, more studies are required to evaluate the benefit, financial cost, and operation time and also to make selection criteria and quality management program.

  12. Common positioning errors in panoramic radiography: A review.

    Science.gov (United States)

    Rondon, Rafael Henrique Nunes; Pereira, Yamba Carla Lara; do Nascimento, Glauce Crivelaro

    2014-03-01

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  13. Critical thinking ability of 3rd year radiography students | Pieterse ...

    African Journals Online (AJOL)

    Background: Developing the critical thinking skills of student radiographers is imperative in an era of rapidly advancing technology. The status of the students' ability to demonstrate critical thinking skills needed to be explored for the Department of Radiography at a comprehensive university to determine if a more explicit ...

  14. Using Periapical Radiography to Differentiate Periapical Granuloma and Radicular Cysts

    Directory of Open Access Journals (Sweden)

    Farhadi

    2016-06-01

    Full Text Available Background The distinction between radicular cysts and apical granulomas is important in treatment decision. Objectives The current study aimed to differentiate these two lesions based on radiography images. Patients and Methods The material consisted of 138 radiographs obtained using Kodak E -speed, in patients aged 29 to 47, divided into two groups: 109 granulomas and 29 radicular cysts. Size of radiography images was measured; the tooth then was extracted and examined in pathologist lab. The results were analyzed by SPSS.15 and ROC curve was created to find cut-off point to differentiate periapical granuloma and radicular cysts. Results Average size of radiography in periapical granuloma was 7.4 mm and for a radicular cyst was 11.1 mm. Cut-off point was 8.2 mm and the area under curve (AUC was 0.63. Also, the tests were 83% sensitive and 79% specific. Conclusions Based on 8.2 mm cut-off point could differentiate 83% periapical granulomas and 79% radicular cysts from radiography images.

  15. Using Periapical Radiography to Differentiate Periapical Granuloma and Radicular Cysts

    OpenAIRE

    Farhadi; Mirinezhad; Zarandi

    2016-01-01

    Background The distinction between radicular cysts and apical granulomas is important in treatment decision. Objectives The current study aimed to differentiate these two lesions based on radiography images. Patients and Methods The material consisted of 138 radiographs obtained using Kodak E -speed, in patients aged 29 to 47, divided into two groups: 109 granulomas and 29 radicula...

  16. Detecting osteoporosis in elderly women using panoramic radiography technique

    Directory of Open Access Journals (Sweden)

    Barunawaty Yunus

    2016-06-01

    Full Text Available Osteoporosis is a systemic disease which characterized by a reduction in bone mass with deterioration microarchitecture of bone and degradation of bone tissue which can be raises loss of bone. Osteoporosis is a problem relating with the aging process. Osteoporosis process actually starts since the age 40-50 years. At this age, men and women will experience shrinkage process of bone mass. in women, this process faster after menopause and is more common in women than men. The technique can be used to detect osteoporosis by performing panoramic radiographic examination techniques. Panoramic radiography is a technique for generating photo of facial structures, including the maxillary bone, mandibular and other support structures. The purpose of this study is to detect the presence of osteoporosis in elderly women using panoramic radiography technique. The subjects of this study is image results of a panoramic radiography with vulnerable women aged 50-70> obtained from the Hospital Radiology section of Unhas, mental indeks measurement is then performed on image results of the panoramic radiographs. Overall regardless of age, the prevalence of osteoporosis reached 10% per 100 population (P>0.05. In conclusion, to detecting osteoporosis in elderly women, panoramic radiographs can be used. The index used is mental index which is an index of panoramic radiography has been developed to detect osteoporosis.

  17. Subtraction Radiography for the Diagnosis of Bone Lesions in Dogs.

    Science.gov (United States)

    1984-05-31

    Avail ander Journal of Periodontology Dist Special Ř 211 East Chicago Avenue Room 924 Chicago, IL 60611 Dear Sirs: I m submitting an original...research article titled "Subtraction Radiography for the Diagnosis of Bone Lesions in Dogs" solely to the Journal of Periodontology for review and

  18. Neutron induced electron radiography; Radiografia com eletrons induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Leandro Garcia

    2008-07-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 {mu}m in 24 {mu}m of aluminum at a resolution of 32 {mu}m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  19. Radiography journals 1935-1940: '1937'

    Energy Technology Data Exchange (ETDEWEB)

    Bentley, H. Brian [Directorate of Radiography, University of Salford, Salford M6 6PU (United Kingdom)

    2009-12-15

    This is the third of the series 1935-1937, two years before the Second World War and sixty-one years ago. There is much to indicate the contribution of physicists, radiologists and radiographers to the under pinning of the science of radiography. We shall continue the series with the period from 1938-1940.

  20. Effective dose in abdominal digital radiography: Patient factor

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Sung; Koo, Hyun Jung; Park, Jung Hoon; Cho, Young Chul; Do, Kyung Hyun [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul(Korea, Republic of); Yang, Hyung Jin [Dept. of Medical Physics, Korea University, Seoul (Korea, Republic of)

    2017-08-15

    To identify independent patient factors associated with an increased radiation dose, and to evaluate the effect of patient position on the effective dose in abdominal digital radiography. We retrospectively evaluated the effective dose for abdominal digital radiography in 222 patients. The patients were divided into two groups based on the cut-off dose value of 0.311 mSv (the upper third quartile of dose distribution): group A (n = 166) and group B (n = 56). Through logistic regression, independent factors associated with a larger effective dose were identified. The effect of patient position on the effective dose was evaluated using a paired t-test. High body mass index (BMI) (≥ 23 kg/m2), presence of ascites, and spinal metallic instrumentation were significantly associated with a larger effective dose. Multivariate logistic regression analysis revealed that high BMI [odds ratio (OR), 25.201; p < 0.001] and ascites (OR, 25.132; p < 0.001) were significantly associated with a larger effective dose. The effective dose was significantly lesser (22.6%) in the supine position than in the standing position (p < 0.001). High BMI and ascites were independent factors associated with a larger effective dose in abdominal digital radiography. Significant dose reduction in patients with these factors may be achieved by placing the patient in the supine position during abdominal digital radiography.

  1. Selection criteria for a radiography programme in South Africa ...

    African Journals Online (AJOL)

    Background: Selection criteria used to admit students to a radiography programme at the Central University of Technology (CUT) included academic criteria, as well as the General Scholastic Aptitude Test (GSAT) and Self-directed Search (SDS) Questionnaire. Aims and objectives: The aim of the study was to identify which ...

  2. Atlas-based knee osteophyte assessment with ultrasonography and radiography

    DEFF Research Database (Denmark)

    Koski, J M; Kamel, Ayadi; Waris, P

    2016-01-01

    OBJECTIVES: To investigate intra- and inter-reader agreement of ultrasonography (US) and conventional radiography (CR) for the evaluation of osteophyte presence and size within the tibiofemoral joint. In addition, to correlate these findings with arthroscopic degeneration of the articular cartilage...

  3. Rethinking responsibility in radiography: Some ethical issues in ...

    African Journals Online (AJOL)

    The field of radiography in South Africa is complex and presents a multitude of ethical issues. The discipline is often regarded as a supporting function in the healthcare chain, and a stepping-stone in the diagnostic process. This status of the discipline seems to have left many radiographers in a position of substantial ...

  4. The importance of dynamic radiography with quadriceps contraction ...

    African Journals Online (AJOL)

    We conducted a prospective, inter- and intra-observer, comparative study on 40 acute ruptures of the anterior cruciate ligament (ACL), comparing the gathered data with the TELOS technique to those obtained from the knee radiography technique with and without quadriceps contraction. Performed by two different ...

  5. Utility of lead thyroid collar in cephalometric radiography

    Directory of Open Access Journals (Sweden)

    Anuraag B Choudhary

    2012-01-01

    Conclusions : Lead shielding of the thyroid gland does not affect landmark identification or the specific measurements of the angulations traced during cephalometric analysis. TCs should be routinely applied during cephalometric radiography if cephalometric analyses are limited to the structures above the second cervical vertebra.

  6. Applications of Neutron Radiography for the Nuclear Power Industry

    Science.gov (United States)

    Craft, Aaron E.; Barton, John P.

    The World Conference on Neutron Radiography (WCNR) and International Topical Meeting on Neutron Radiography (ITMNR) series have been running over 35 years. The most recent event, ITMNR-8, focused on industrial applications and was the first time this series was hosted in China. In China, more than twenty new nuclear power plants are under construction and plans have been announced to increase the nuclear capacity by a factor of three within fifteen years. There are additional prospects in many other nations. Neutron tests were vital during previous developments of materials and components for nuclear power applications, as reported in the WCNR and ITMNR conference series. For example a majority of the 140 papers in the Proceedings of the First WCNR are for the benefit of the nuclear power industry. Many of those techniques are being utilized and advanced to the present time. Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Applications include examination of nuclear waste, nuclear fuels, cladding, control elements, and other critical components. In this paper, applications of neutron radiography techniques developed and applied internationally for the nuclear power industry since the earliest years are reviewed, and the question is asked whether neutron test techniques, in general, can be of value in development of the present and future generations of nuclear power plants world-wide.

  7. Radiography Capabilities for Matter-Radiation Interactions in Extremes

    Energy Technology Data Exchange (ETDEWEB)

    Walstrom, Peter Lowell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garnett, Robert William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chapman, Catherine A. B [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Salazar, Harry Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Otoole, Joseph Alfred [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Barber, Ronald L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gomez, Tony Simon [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-04-28

    The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electron and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.

  8. The value of thyroid shielding in intraoral radiography

    NARCIS (Netherlands)

    Hoogeveen, R.C.; Hazenoot, B.; Sanderink, G.C.H.; Berkhout, W.E.R.

    2016-01-01

    Objectives: To evaluate the utility of the application of a thyroid shield in intraoral radiography when using rectangular collimation. Methods: Experimental data were obtained by measuring the absorbed dose at the position of the thyroid gland in a RANDO® (The Phantom Laboratory, Salem, NY) male

  9. Effective dose of 3 types machines with panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, Kazuo; Honjoya, Takashi; Sawada, Kunihiko; Satomi, Reiko; Hashimoto, Koji; Shinoda, Koji; Maruyama, Takashi [Nihon Univ., Tokyo (Japan). School of Dentistry

    2000-01-01

    A study was done to measure and compare the organ and tissue doses of radioactivity during panoramic X-ray radiography using three types of device. The panoramic X-ray machines used were an HIDA N70-R100 (orthopantomography), a Morita Veraview (elipsopantomography), and a Philips Stat ORALIX (intra-oral tube panoramic radiography). The organs and tissues for which the radiation dose was measured were the red bone marrow, thyroid gland, lungs, stomach, large intestine, liver, esophagus, breast, bladder, eyes, brain and salivary glands. National UD-170A and UD-110S thermoluminescent dosimeters were used for measurement. These were calibrated with a standard dosimeter from the National Institute of Radiological Sciences. The measurements were done using a RANDO woman phantom. The effective doses were calculated as 9.1, 15.2 and 11.6 {mu}Sv by intraoral panoramic radiography of the upper, lower and lateral, respectively. The effective doses during panoramic radiography for the elipso and or ortho machines were 16.1 and 24.9 {mu}Sv, respectively. (author)

  10. Chest Radiography in Management of Breast Cancer Patients in a

    African Journals Online (AJOL)

    The main objective of this study was to determine the role of abdominal ultrasound and chest radiography in detection of liver and lung metastasis in newly diagnosed breast cancer patients. Methods: This was a descriptive cross sectional study in which 103 new breast cancer patients attending Ocean Road Cancer ...

  11. Positive experience of a mobile radiography service in nursing homes.

    Science.gov (United States)

    Eklund, Karin; Klefsgård, Rosemarie; Ivarsson, Bodil; Geijer, Mats

    2012-01-01

    For elderly people living in nursing homes, a transport to hospital for a radiological examination can lead to increased anxiety, disorientation and other problems related to the new environment. To investigate the usefulness of a mobile radiography service for radiological assessment of patients in nursing homes from the patient and staff perspectives. Lightweight equipment with a digital flat-panel detector was used for mobile radiography on nursing home patients in their own rooms. Data on patient and staff experiences from the service were collected using a questionnaire with closed and open-ended questions. Image quality was evaluated by the radiographer and a radiologist. The majority of 241 radiography examinations were of the musculoskeletal system (94%). Twelve of 123 patients had pathology that required hospital treatment, while 22 patients with radiographic pathology could be treated locally. The main beneficial factors were security and comfort, acceptance from the patients, no need for transportation, no need for staff to be absent from the nursing homes. Mobile radiography in nursing homes is technically feasible, with good image quality. The most beneficial results were that patients avoided unnecessary transport back and forth to the hospital, and that the majority of patients could be treated locally. Copyright © 2011 S. Karger AG, Basel.

  12. Preliminary results of a study comparing conventional radiography with phase-contrast radiography for assessing root morphology of mandibular third molars

    Science.gov (United States)

    Sato, T; Nakamoto, N; Abe, T; Fukushima, Y; Tomaru, Y; Sakata, Y; Nakazawa, M; Nakamoto, A; Kawasaki, H; Wada, Y; Ohara, H; Araki, R; Tanaka, J; Yoda, T

    2011-01-01

    Objectives The aim of this study was to evaluate the usefulness of phase-contrast radiography for assessing root morphology of mandibular third molars in comparison with conventional radiography. Methods We studied 37 extracted mandibular third molars. One oral surgeon compared the number of roots and root curvature of the extracted teeth on conventional radiographs with those on phase-contrast images. Results The number of roots and root curvature on conventional images differed significantly from those on phase-contrast images. Conclusions Our results suggest the possibility that phase-contrast radiography is more useful than conventional radiography for assessing the root morphology of mandibular third molars. PMID:21239571

  13. Quality aspects of digital radiography in general dental practice.

    Science.gov (United States)

    Hellén-Halme, Kristina

    2007-01-01

    The number of dentists who have converted from conventional film radiography to digital radiography continues to grow. A digital system has numerous advantages, but there are also many new aspects to consider. The overall aim of this thesis was to study how digital radiography was used in general dental practices. The specific aims were to study how different factors affected image quality. To determine whether there were any differences in image quality between conventional film radiographs and digital radiographs, 4863 images (540 cases) were evaluated. The cases had been sent to the Swedish Dental Insurance Office for prior treatment approval. The image quality of digital radiographs was found to be significantly lower than that of film radiographs. This result led to a questionnaire study of dentists experienced in digital radiography. In 2003, a questionnaire was sent to the 139 general practice dentists who worked with digital radiography in Skine, Sweden; the response rate was 94%. Many general practice dentists had experienced several problems (65%), and less than half of the digital systems (40%) underwent some kind of quality control. One of the weaker links in the technical chain of digital radiography appeared to be the monitor. A field study to 19 dentists at their clinics found that the brightness and contrast settings of the monitors had to be adjusted to obtain the subjectively best image quality. The ambient light in the evaluation room was also found to affect the diagnostic outcome of low-contrast patterns in radiographs. To evaluate the effects of ambient light and technical adjustments of the monitor, a study using standardised set-ups was designed. Seven observers evaluated radiographs of 100 extracted human teeth for approximal caries under five different combinations of brightness and contrast settings on two different occasions with high and low ambient light levels in the evaluation room. The ability to diagnose carious lesions was found

  14. Diagnostic reference levels in intraoral dental radiography in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung; Han, Won Jeong; Choi, Jin Woo [Dept. of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Cheonan (Korea, Republic of); Jung, Yun Hoa [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Pusan National University, Yangsan (Korea, Republic of); Yoon, Suk Ja; Lee, Jae Seo [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Chonnam National University, Gwangju (Korea, Republic of)

    2012-09-15

    The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 mGycm2 (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 mGycm{sup 2} (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). We recommend 3.1 mGy (PED), 87.4 mGycm{sup 2} (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

  15. [Computed tomography semiotics of osteonecrosis and sequestration in chronic hematogenic osteomyelitis].

    Science.gov (United States)

    D'iachkova, G V; Mitina, Iu L

    2007-01-01

    Based on the data of computed tomography, radiography and densitometry in 39 patients the authors describe in detail the signs of osteonecrosis and sequestration of different localization and extension.

  16. Radiation-absorbed doses and energy imparted from panoramic tomography, cephalometric radiography, and occlusal film radiography in children

    Energy Technology Data Exchange (ETDEWEB)

    Bankvall, G.; Hakansson, H.A.

    1982-05-01

    The absorbed doses and energy imparted from radiographic examinations of children, using panoramic tomography (PTG), cephalometric radiography (CPR), and maxillary frontal occlusal overview (FOO), were examined. The absorbed dose at various sites of the head were measured with TL dosimeters in a phantom and in patients. The energy imparted was calculated from measurements of areal exposure using a planparallel ionization chamber. The maximum absorbed doses for panoramic tomography were located around the lateral rotation center, for cephalometric radiography in the left (tube side) parotid region, and for frontal occlusal radiography in the nose. The absorbed doses in the eyes, thyroid gland, and skin are discussed and compared with previous reports and, for the most part, are found to be in agreement. The mean energy imparted from all three examination methods is 5 mJ with about 57 percent from panoramic, 33 percent from cephalometric, and 10 percent from frontal occlusal examinations. The energy imparted from cephalometric radiography can be reduced to about 10 percent with the use of an improved examination technique, leaving panoramic tomography responsible for contributing about 80 percent of the total energy imparted.

  17. Images of ameloblastoma: from radiography to tomography

    Directory of Open Access Journals (Sweden)

    Raúl Herrera-Mujica

    2015-07-01

    Full Text Available Odontogenic tumors are a group of lesions originated from odontogenesis course alterations. Within odontogenic tumors is ameloblastoma, its treatment probably is one of the most controversial, because its aggressive behavior, high recurrence and probably low malignancies. Radiographs play an important role in assessment from this tumor, but the limitation is they are in two dimensions exams. Cone beam computed tomography is a valuable tool because enable a comprehensive assessment of anatomical structures by multiple sections of the area. Therefore, evaluation of ameloblastoma is complete by cone beam computed tomography because bone structures do not show distortion neither magnification.

  18. Earthquake-related pelvic crush fracture vs. non-earthquake fracture on digital radiography and MDCT: a comparative study

    Science.gov (United States)

    Chen, Tian-wu; Yang, Zhi-gang; Dong, Zhi-hui; Tang, Si-shi; Chu, Zhi-gang; Shao, Heng

    2011-01-01

    OBJECTIVE: To determine the features of earthquake-related pelvic crush fractures versus non-earthquake fractures with digital radiography and multidetector row computed tomography. METHODS: One hundred and sixty-seven survivors with pelvic crush fractures in the 2008 Sichuan earthquake were entered in our study as the earthquake-related group (139 underwent digital radiography, 28 underwent multidetector row computed tomography); 70 victims with non-earthquake pelvic fractures were enrolled into this study as the non-earthquake group (54 underwent digital radiography, 16 underwent multidetector row computed tomography). Data were reviewed retrospectively between groups, focusing on anatomic distributions, status of pelvic bone fractures, numbers of pelvic bones involved, and classification of pelvic ring fractures according to the Tile classification system. RESULTS: Pelvic fractures occurred more frequently in the pubis in the earthquake-related group than in the non-earthquake group (135/167, 81% vs. 48/70, 69%). In addition, comminuted fractures were more common in the earthquake-related group than in the non-earthquake group (55/167, 33% vs. 10/70, 14%). Multiple fractures were less common in the earthquake-related group than in the non-earthquake group (81/167, 49% vs. 46/70, 66%). Regarding the classification of pelvic ring fractures, Type C predominantly composed of subtype C3 occurred more frequently (64/167, 38% vs. 12/70, 17%), and Type A was less common in the earthquake-related group than in the non-earthquake group (31/167, 19% vs. 23/70, 32%). All differences were statistically significant (pfractures between the groups (72/167, 43% vs. 35/70, 50%). CONCLUSION: Earthquake-related pelvic crush fractures can be characterized by a high incidence of pelvic fractures occurring in the pubis, comminuted fractures, and Type C fractures predominantly composed by subtype C3, despite a low incidence of multiple fractures. PMID:21655758

  19. Segmental lumbar spine instability at flexion-extension radiography can be predicted by conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Pitkaenen, M.T.; Manninen, H.I.; Lindgren, K.-A.J.; Sihvonen, T.A.; Airaksinen, O.; Soimakallio, S

    2002-07-01

    AIM: To identify plain radiographic findings that predict segmental lumbar spine instability as shown by functional flexion-extension radiography. MATERIALS AND METHODS: Plain radiographs and flexion-extension radiographs of 215 patients with clinically suspected lumbar spine instability were analysed. Instability was classified into anterior or posterior sliding instability. The registered plain radiographic findings were traction spur, spondylarthrosis, arthrosis of facet joints, disc degeneration, retrolisthesis, degenerative spondylolisthesis, spondylolytic spondylolisthesis and vacuum phenomena. Factors reaching statistical significance in univariate analyses (P < 0.05) were included in stepwise multiple logistic regression analysis. RESULTS: Degenerative spondylolisthesis (P = 0.004 at L3-4 level and P = 0.017 at L4-5 level in univariate analysis and odds ratio 16.92 at L4-5 level in multiple logistic regression analyses) and spondylolytic spondylolisthesis (P = 0.003 at L5-S1 level in univariate analyses) were the strongest independent determinants of anterior sliding instability. Retrolisthesis (odds ratio 10.97), traction spur (odds ratio 4.45) and spondylarthrosis (odds ratio 3.20) at L3-4 level were statistically significant determinants of posterior sliding instability in multivariate analysis. CONCLUSION: Sliding instability is strongly associated with various plain radiographic findings. In mechanical back pain, functional flexion-extension radiographs should be limited to situations when symptoms are not explained by findings of plain radiographs and/or when they are likely to alter therapy. Pitkaenen, M.T. et al. (2002)

  20. CMOS digital intra-oral sensor for x-ray radiography

    Science.gov (United States)

    Liu, Xinqiao; Byczko, Andrew; Choi, Marcus; Chung, Lap; Do, Hung; Fowler, Boyd; Ispasoiu, Radu; Joshi, Kumar; Miller, Todd; Nagy, Alex; Reaves, David; Rodricks, Brian; Teeter, Doug; Wang, George; Xiao, Feng

    2011-03-01

    In this paper, we present a CMOS digital intra-oral sensor for x-ray radiography. The sensor system consists of a custom CMOS imager, custom scintillator/fiber optics plate, camera timing and digital control electronics, and direct USB communication. The CMOS imager contains 1700 x 1346 pixels. The pixel size is 19.5um x 19.5um. The imager was fabricated with a 0.18um CMOS imaging process. The sensor and CMOS imager design features chamfered corners for patient comfort. All camera functions were integrated within the sensor housing and a standard USB cable was used to directly connect the intra-oral sensor to the host computer. The sensor demonstrated wide dynamic range from 5uGy to 1300uGy and high image quality with a SNR of greater than 160 at 400uGy dose. The sensor has a spatial resolution more than 20 lp/mm.

  1. Detection of lung nodules. New opportunities in chest radiography; Detektion pulmonaler Rundherde. Neue Moeglichkeiten der Thoraxradiographie

    Energy Technology Data Exchange (ETDEWEB)

    Poetter-Lang, S. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Department of Biomedical Imaging and Image-Guided Therapy, Wien (Austria); Schalekamp, S. [Radboud University Nijmegen Medical Center, Nijmegen (Netherlands); Schaefer-Prokop, C. [Radboud University Nijmegen Medical Center, Nijmegen (Netherlands); Meander Medical Center Amersfoort, Amersfoort (Netherlands); Uffmann, M. [Landesklinikum Neunkirchen, Abteilung fuer Radiodiagnostik, Neunkirchen (Germany)

    2014-05-15

    Chest radiography still represents the most commonly performed X-ray examination because it is readily available, requires low radiation doses and is relatively inexpensive. However, as previously published, many initially undetected lung nodules are retrospectively visible in chest radiographs. The great improvements in detector technology with the increasing dose efficiency and improved contrast resolution provide a better image quality and reduced dose needs. The dual energy acquisition technique and advanced image processing methods (e.g. digital bone subtraction and temporal subtraction) reduce the anatomical background noise by reduction of overlapping structures in chest radiography. Computer-aided detection (CAD) schemes increase the awareness of radiologists for suspicious areas. The advanced image processing methods show clear improvements for the detection of pulmonary lung nodules in chest radiography and strengthen the role of this method in comparison to 3D acquisition techniques, such as computed tomography (CT). Many of these methods will probably be integrated into standard clinical treatment in the near future. Digital software solutions offer advantages as they can be easily incorporated into radiology departments and are often more affordable as compared to hardware solutions. (orig.) [German] Das Thoraxroentgen mit den Vorteilen der schnellen Verfuegbarkeit, geringen Strahlendosis und geringen Kosten ist unveraendert die haeufigste radiologische Untersuchung. Es wurde jedoch vielfach publiziert, dass primaer im Thoraxroentgen uebersehene Lungenrundherde retrospektiv sichtbar waren. Die grossen Fortschritte der Detektortechnologie mit verbesserter Dosiseffizienz und Ortsaufloesung der Systeme fuehren zu einer gesteigerten Bildqualitaet bei geringerem Dosisbedarf. Die Dual-energy-Aufnahmetechnik sowie auch Bildverarbeitungsmethoden wie die digitale Knochensubtraktion und die ''temporal subtraction'' reduzieren das &apos

  2. Modelo de anestesia em coelhos para procedimentos no tórax Anesthesia model in rabbits for thoracic surgery

    Directory of Open Access Journals (Sweden)

    Elias Kallas

    2001-06-01

    Full Text Available A intubação endotraqueal em coelhos é dificil. O risco anestésico não é desprezível pela estreita margem de segurança entre o plano anestésico e o óbito. Tais fatos despertaram nosso interesse por uma solução simples e segura. Dez animais machos receberam por via intramuscular acepromazina, cetamina e xilazina. Após dez minutos procedeu-se exposição do ligamentum cricothyroideum , o qual foi incisado para colocação de tubo endotraqueal iniciando-se a administração de oxigênio e halotano. A punção arterial foi realizada para controle da pressão arterial média. Procedeu-se toracotomia no quinto espaço intercostal esquerdo com biópsia do pulmão e colabamento pulmonar, iniciando-se a ventilação seletiva do pulmão contra-lateral. Amostras sangüíneas, para medida do pH, foram colhidas no início do procedimento, após o colabamento pulmonar e no final, antes da expansão do pulmão, 30 minutos após o colabamento. Fechado o tórax, foi retirado o tubo endotraqueal tão logo o animal apresentasse recuperação dos reflexos e a seguir suturado ligamentum cricothyroideum. Os animais foram submetidos a eutanásia 14 dias após, quando procedeu-se a nova biópsia pulmonar, a retirada da traquéia e da laringe, para exame. Concluiu-se que este é um procedimento simples e seguro de anestesia para cirurgia torácica em coelhos.The endotracheal intubation of rabbits is difficult. The anesthetic risk is high because of the narrow difference between the effective and the lethal dose. We used a safe and simple method. Ten male animals received intramuscular injection of acepromazine, cetamine, and xylazine. Ten minutes later, an endotracheal canula was inserted trough a small cervical incision on the crico-tyroid membrane, to administrate oxigen and halothane. Thoracotomy was performed in the 5th. left intercostal space and a pulmonary biopsy too. The left lung collapsed and ventilation of the right lung remained for the next 30

  3. Câncer do reto médio: avaliação do procedimento cirúrgico

    Directory of Open Access Journals (Sweden)

    José Hyppólito da Silva

    Full Text Available A conduta no tratamento cirúrgico do câncer do reto médio é ainda controversa. Vários procedimentos cirúrgicos foram avaliados, retrospectivamente, em noventa doentes operados durante o período de fevereiro de 1990 a junho de 1997. Deste total, 43 (47,7% doentes eram do sexo feminino e 47 (52,3% do masculino. A idade variou entre 20 e 90 anos, com média de 60,2 anos. Os principais sintomas e sinais foram puxo e tenesmo, hematoquesia e emagrecimento. O tempo decorrido desde o início dos sintomas até o diagnóstico variou de dois a 24 meses, com média de 7,5 meses. A amputação abdômino-perineal do reto foi realizada em 17 doentes (18,8% e a complicação mais freqüente foi a deiscência da ferida perineal, em 47% dos casos. Um doente (1,1 % foi submetido a proctocolectomia total, evoluindo sem intercorrências. A operação de Hartmann foi feita em 26 doentes (28,8%, ocorrendo 7,6% de morbidade e 7,6% de mortalidade, em virtude de complicações clínicas. Em 26 doentes (28,8%, foi realizada ressecção anterior seguida de anastomose. Em dez (11,1%, foi realizada anastomose manual e não houve complicações. Nos outros 16 (17,7% foi feita anastomose mecânica, havendo três deiscências e um óbito, relacionado a complicações clínicas. Em oito doentes (8,8%, foi realizada ressecção com abaixamento coloanal, ocorrendo 50% de complicações, devido à necrose e à retração do cólon abaixado. Houve apenas um óbito relacionado à complicação cirúrgica. Em 12 doentes (13,3% não foi efetuada a ressecção do tumor, em decorrência de precárias condições clínicas dos mesmos e falta de critérios de ressecabilidade da lesão. Concluímos que o procedimento cirúrgico adequado no tratamento do câncer do reto médio depende de estadiamento criterioso, considerando o grau de diferenciação celular, a presença de metástase, a condição local do tumor, a situação clínica do doente e a experiência da equipe cirúrgica.

  4. Tratamento cirúrgico da doença pilonidal: meta-análise dos principais procedimentos adotados mundialmente

    Directory of Open Access Journals (Sweden)

    Victor Strassmann

    Full Text Available OBJETIVO: Analisar e comparar os diversos procedimentos cirúrgicos descritos para o tratamento da doença pilonidal. MÉTODO: Foram selecionados 34 trabalhos publicados em revistas indexadas, totalizando 8698 doentes operados. Realizou-se meta-análise para comparação das sete principais técnicas cirúrgicas descritas na literatura, quanto aos resultados em relação à recidiva e ao tempo de cicatrização no pós-operatório. RESULTADOS: Do total de doentes estudados, houve recidiva em 230 doentes (2,6%. O tempo de cicatrização no pós-operatório foi significantemente maior no grupo de excisão sem sutura. As recidivas foram estatisticamente semelhantes nos métodos: excisão sem sutura, marsupialização, incisão e curetagem, excisão e retalho e técnica de Karidakys. Os métodos que apresentaram maior índice de recidiva (estatisticamente significante - p<0,001 foram: excisão e sutura primária e o método de Bascom. CONCLUSÕES: Conclui-se, por esse estudo, que os resultados em relação à recidiva são estatisticamente semelhantes em todos os métodos, com exceção da excisão e sutura primária e da técnica de Bascom, que apresentaram recidivas mais freqüentes. O tempo de cicatrização foi maior nos indivíduos operados pela técnica de excisão sem sutura primária.

  5. Validity of a frustration-induction procedure Validade de um procedimento para indução de frustração

    Directory of Open Access Journals (Sweden)

    Elaine Henna

    2008-03-01

    Full Text Available OBJECTIVE: To test a reliable and easily administered frustration-induction procedure for experimental research. METHOD: One hundred volunteers (81 women, mean age ± SD 34.2 ± 8 years physically and psychiatrically healthy submitted to the frustration induction procedure were prevented from reaching reward level scores. Subjective aggressiveness feelings related to frustration were self-rated in a 13-item visual analogue scale before and after the procedure. RESULTS: Significant increases in aggressiveness-related feelings were detected in 12 of the 13 items. This was consistent with the observed overt behavior of the subjects during the task. CONCLUSIONS: The frustration-induction procedure is a simple, easy to administer frustration-induction procedure that can be used in experimental studies in normal subjects.OBJETIVO: Testar um procedimento de indução de frustração confiável e de simples aplicação para a pesquisa experimental. MÉTODO: Cem voluntários (81 mulheres, idade média ± DP 34,2 ± 8 anos, física e psiquiatricamente saudáveis, submetidos ao procedimento de indução de frustração, foram impedidos de atingir escores de recompensa. Os sentimentos de agressividade subjetivos relacionados à frustração foram autoclassificados em um escala analógica visual de 13 itens antes e após o procedimento. RESULTADOS: Foram detectados aumentos significativos nos sentimentos relacionados à agressividade em 12 dos 13 itens. Isto foi consistente com o comportamento manifestado pelos indivíduos e observado durante a tarefa. CONCLUSÕES: O procedimento de indução de frustração é simples, facilmente aplicável e que pode ser utilizado em estudos experimentais com indivíduos normais.

  6. Enfisema em decorrência de procedimentos odontológicos: revista de literatura = Surgical emphysema due dental procedures: review of the literature

    Directory of Open Access Journals (Sweden)

    Kreisner, Paulo Eduardo

    2005-01-01

    Full Text Available Enfisema é um acidente relativamente raro que pode ocorrer em decorrência de procedimentos odontológicos. Apesar da maioria dos casos se resolverem espontaneamente, eles podem levar a complicações que exijam uma intervenção de emergência. É importante um correto diagnóstico, bem como um adequado manejo desta condição. Decidiu-se realizar uma revista

  7. Quality control of virtual wedge in a linear electron accelerator with a computerized radiography system (CR); Control de calidad de la cuna virtual en un acelerador lineal de electrones mediante un sistema de radiografia competerizada (CR)

    Energy Technology Data Exchange (ETDEWEB)

    Ordiales, J. M.; Alvarez, F. J.; Falero, B.

    2011-07-01

    For quality control of the virtual wedge there are several systems on the market as arrays of detectors or ionization chambers, linear or 2D configuration, radiochromic films or digital imaging systems incorporated in electron linear accelerators (ALE ). The present work aims at implementing a system of Computed Radiography (CR) for a routine check of the virtual wedge.

  8. Using cone beam computed thomography in planning the extraction of impacted third molars

    Directory of Open Access Journals (Sweden)

    Vlahović Zoran

    2016-01-01

    Full Text Available The panoramic radiography is the most used diagnostic imaging method in planning impacted lower third molar extractions. However, often panoramic radiography does not provide enough information in treatment planning for performing safely surgical extraction of impacted third molars. CBCT (Cone beam computed tomography provides more precise information in diagnostic analysis especially for planning surgical procedures where complications can be expected due to close relationship between mandibular canal and lower impacted third molars. The aim of this study is comparative analysis of panoramic radiography and CBCT in evaluating the topographic relationship between mandibular canal and impacted third molars. The study included 50 patients with close relationship between mandibular canal and impacted third molars detected using panoramic radiography. After panoramic radiography analysis CBCT was performed in order to diagnose, plan and prevent complications during the surgical tooth extraction. CBCT examination considered comparative analysis with panoramic radiography, marking, volume rendering and assessment of mandibular canal in buccolingual direction. Out of total patients where suprimposition of mandibular canal and impacted third molar on panoramic radiography was detected, in 32 patients mandibular chanal was localised on lingual side. Mandibular canal was positioned at bucal side in 18 of 50 patients. Results of this research indicate that panoramic radiography can be useful in everyday practice for diagnosis, planning and preparing lower third molar extractions, but in cases where close relationship between mandibular canal and lower third molars is detected CBCT is recommended as more precise radiographic imaging method in order to prevent complications.

  9. Percepções dos pacientes quanto aos procedimentos invasivos no pós-operatório de cirurgias de grande porte

    Directory of Open Access Journals (Sweden)

    Maria Eunice Medeiros Teixeira

    1994-09-01

    Full Text Available Estudo descritivo, com abordagem qualitativa, onde as percepções dos pacientes submetidos a cirurgias de grande porte, em relação aos procedimentos invasivos, foram objetos centrais. O local onde o estudo se desenvolveu foi a clínica cirúrgica de um hospital de ensino em Goiânia. A população constituiu-se de pacientes submetidos de procedimentos invasivos de ambos os gêneros, com faixa etária entre dezoito e sessenta e nove anos. A entrevista semi-estruturada e a observação direta foram utilizadas para a coleta de dados. Os resultados apresentados em três categorias, evidenciaram pouca orientação e interação profissionais-pacientes. A sonda nasogástrica foi o procedimento invasivo que mais incomodou o grupo pesquisado. Aspectos não esperados referentes ao tratamento foram também descritos neste estudo.

  10. O Procedimento Selective Reminding na Avaliação da Memória e Aprendizagem: Um Levantamento de Estudos Brasileiros

    Directory of Open Access Journals (Sweden)

    Suelen Bordignon

    Full Text Available RESUMO Os pesquisadores têm à sua disposição uma variedade de métodos que auxiliam a compreensão dos processos de memória e aprendizagem. O presente artigo tem como objetivo revisitar o procedimento de recordação seletiva, apresentando suas características e variações, e realizar um levantamento de estudos brasileiros que fizeram uso do mesmo. São apresentadas as diferenças entre a recordação seletiva e o procedimento padrão em tarefas de aprendizagem por recordação livre. Constatou-se que, no Brasil, além de diferentes tarefas, são utilizadas formas de aplicações distintas do procedimento. A utilização da recordação seletiva apresenta relevância no estudo da memória e da aprendizagem, em especial na busca pela diferenciação entre as dificuldades normais de memórias e os déficits patológicos dessa função cognitiva.

  11. Reference dose levels for dental periapical radiography in Chonnam Province

    Energy Technology Data Exchange (ETDEWEB)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja [Department of Oral and Maxillofacial Radiology, College of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Lee, Jae Seo [Department of Oral and Maxillofacial Radiology, Chonnan National University Hospital, Gwangju (Korea, Republic of); Kim, Young Hee [Department of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital, Chuncheon (Korea, Republic of)

    2009-12-15

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  12. Dose in conventional radiography; Dosis en radiografia convencional

    Energy Technology Data Exchange (ETDEWEB)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98000 Zacatecas (Mexico)

    2011-10-15

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, howe