WorldWideScience

Sample records for complete denture teaching

  1. An investigation of complete denture teaching in the UK: part 1. A survey of undergraduate teaching.

    Science.gov (United States)

    Wieder, M; Faigenblum, M; Eder, A; Louca, C

    2013-08-01

    This paper is the first in a series of two that investigate the undergraduate teaching of complete dentures in the UK. A questionnaire was sent by email to 13 UK dental schools enquiring about the number of hours spent in the lecture theatre, laboratory and clinic. The schools were also asked to give their views about the preparedness of the new graduates for dealing with complete dentures in general practice. There was great disparity between schools in the overall number of lectures delivered. Two schools claimed 28 hours and the remainder varied between 6-15 hours. Four schools devoted more time to laboratory work whereas three schools spent more time in the clinic. One school reported no dedicated clinical time for complete dentures. There appears to be a regional variation with northern UK dental schools spending more time on the teaching of complete dentures. The quota for complete dentures varied from three in most schools to eight in one school and none in another. Comments from the dental schools varied from a reported lack of suitable complete denture cases, to concerns with insufficient curricular time devoted to the subject and a subsequent lack of clinical competence on graduation. Some schools have integrated complete denture teaching into the general prosthodontic course as it is considered inappropriate to teach different aspects of prosthetics in isolation. Competence in complete dentures falls short of what is expected. With a single exception all the schools seem to have low expectations for their undergraduate students to be practically trained and experienced in the production of complete dentures. Despite the advent of implants and the introduction of clinical dental technicians, there is and will continue to be a need for the competent treatment of the edentulous population by general practitioners.

  2. Characterization of complete denture

    National Research Council Canada - National Science Library

    Srivastava, Rajeev; Choukse, Vivek

    2011-01-01

    Characterization is a procedure in which the character or collective qualities of a person are introduced in the complete denture, either by modification of teeth or denture bases, to make it appear...

  3. Hollow Maxillary Complete Denture

    National Research Council Canada - National Science Library

    Radke, Usha; Mundhe, Darshana

    2011-01-01

    .... The resorption occurs at a faster rate in mandibular arch as compared to the maxillary arch; but severely atrophic maxillae with large interridge distance often pose a clinical challenge during fabrication of a successful maxillary complete denture...

  4. An investigation of complete denture teaching in the UK: part 2. The DF1 experience.

    Science.gov (United States)

    Wieder, M; Faigenblum, M; Eder, A; Louca, C

    2013-09-01

    This paper, the second in a series of two (see 2013; 215: 177-181), investigates the opinions of a cohort of dental foundation year 1 (DF1) practitioners regarding their skills and competence in relation to their educational background in complete dentures. With the permission of the Dean of the London Deanery a questionnaire was emailed to the ten London Foundation year 1 training schemes for distribution to approximately 100 DF1s. Five schemes responded with total of 56 completed questionnaires (56%). The average number of complete dentures made as undergraduates was three. Forty-six percent had no experience in making copy dentures. An average of 2 (median 2.05) immediate replacement dentures were made; only 10% made 8-15 dentures. None had experience in implant-supported dentures. Thirty-five percent enjoyed their undergraduate training whereas 45% did not. Thirty-seven percent felt that their training had given them experience and confidence in complete dentures but 32% were of the opposite opinion. Sixty-three percent felt complete dentures were an important or very important aspect of dentistry. Six percent completely disagreed. The majority were confident in making impressions while 39% lacked confidence in registering jaw relations. Thirty-five percent were confident with chairside adjustments at the intermediary treatment stages but 28% were not. Sixty-three percent were confident in the fitting of new dentures and 64% with the after-care. There was no significant gender difference in the responses. There was a significant difference between the London and non-London trained DF1s. The London trained respondents made significantly fewer dentures than the non-London trained cohort. The latter also rated complete denture treatment as being more important. The comments section revealed that 43% felt that they had a lack of experience; only 5% were confident, 16% thought that complete denture treatment would become obsolete and only 5% recognised the

  5. Using Standardized Patients to Teach Complete Denture Procedures in Second Year of Dental School.

    Science.gov (United States)

    Johnson, Gary M; Halket, Christine A; Ferguson, Gilda P; Perry, Jeffrey

    2017-03-01

    Second-year dental students are commonly instructed on the process of complete denture fabrication with a traditional didactic lecture and preclinical dental laboratory education model. The problem with this limited mode of instruction is that dental students often fail to understand the various chairside procedures required to fabricate a complete denture. The aim of this study was to investigate the use of standardized dental patients to enhance students' understanding of the procedures involved with each appointment in the complete denture process. The Midwestern University College of Dental Medicine-Arizona created an event using standardized patients in four simulated chairside dental appointments for complete denture instruction of second-year dental students. Each appointment simulated the various sequential chairside procedures required to fabricate complete dentures. Following the didactic and dental laboratory instruction and the standardized patient event, a survey was conducted requesting the students' response to six statements regarding their understanding of the denture fabrication process. Of the 110 students who participated in the instructional events, 107 responded to the survey (97% response rate). These students responded very favorably to the simulated appointments, with the majority agreeing or strongly agreeing that their best understanding of the complete denture process was obtained through the standardized patient experiences. The use of standardized patients in simulated denture fabrication appointments enhanced the educational experience of these students when added to the traditional didactic lecture and preclinical laboratory education format. The experience has since been incorporated into the school's second-year oral health science laboratory curriculum.

  6. Prognoses of new complete dentures from the patient's denture assessment of existing dentures.

    Science.gov (United States)

    Komagamine, Yuriko; Kanazawa, Manabu; Sasaki, Yoshiyuki; Sato, Yusuke; Minakuchi, Shunsuke

    2017-06-01

    The aim was to determine prognostic factors affecting frequent post-delivery adjustments of new complete dentures using patients' assessments of existing complete dentures. A total of 125 edentulous participants (56 men, 69 women; mean age, 76.4 years) who required new complete dentures evaluated existing dentures using the patient's denture assessment (PDA), a questionnaire regarding the self-assessment of dentures composed of 22 question items and containing six subscales: "function," "lower denture," "upper denture," "expectation," "esthetics and speech," and "importance." Moreover, the numbers of post-delivery adjustments of new dentures were recorded. A multiple logistic regression analysis was performed to identify significant factors for frequent adjustments of new dentures with five subscales of the PDA (excluding "importance"), level of mandibular ridge resorption, and age as independent variables. The analysis showed that "function," "esthetics and speech," and level of mandibular ridge resorption were significant variables for a frequent number of post-delivery adjustments of new complete dentures. The results suggested that patients' assessments of existing dentures using the PDA might allow a prediction of prognosis for complete denture treatments. Additionally, low "function" scores and high "esthetics and speech" scores for existing dentures and high levels of mandibular ridge resorption were significant prognostic factors affecting frequent post-delivery adjustments of new complete dentures. It may be difficult for edentulous persons to adapt to new complete dentures, especially those who have complaints about mastication and swallowing with existing dentures and poor mandibular ridges, but are satisfied with esthetics and speech.

  7. Complete Denture in a Microstomia Patient

    National Research Council Canada - National Science Library

    Satpathy, Ashish; Gujjari, Anil K

    2015-01-01

    .... It's the duty of a dentist to provide every possible care to the patient with microstomia. This paper describes the treatment of a microstomia patient requiring complete dentures using sectional dentures...

  8. Denture hygiene habits among elderly patients wearing complete dentures.

    Science.gov (United States)

    Apratim, Abhishek; Shah, Sanket S; Sinha, Manish; Agrawal, Manisha; Chhaparia, Nidhi; Abubakkar, Abu

    2013-11-01

    To determine the denture hygiene habits in complete denture patients according to their age and time of dentures. In this study a self administered structured was developed to know the attitude of the patients regarding denture hygiene in the department of Prosthodontics. The total study sample consisted of 230 subjects including 124 (53.9%) males and 106 (46.1%) females. Data was analyzed using SPSS version 15.0 with chi-square test at p-value dentures daily once. Participants from the younger age group and who had been wearing dentures since 2 years maintain better frequency of cleaning. The majority of these subjects used water and brush for denture cleansing. After seeing the condition, half of the dentures were rated as good 50.3%, followed by fair and poor as 29.5 and 20.2% respectively. Poor condition of complete dentures seen in the population is mainly due to irregularly cleansing habits and also less usage of cleansing solutions. Dentists should give proper instructions regarding maintenance of denture hygiene.

  9. Denture Care Practices and Perceived Denture Status among Complete Denture Wearers.

    Science.gov (United States)

    Kosuru, Krishnam Raju V; Devi, Ganji; Grandhi, Vikram; Prasan, Kumar K; Yasangi, Manoj K; Dhanalakshmi, Mannem

    2017-01-01

    Considerable importance to oral health care was lacking in India, and oral health neglect continues to exist, which is evident in the low utilization rates and poor oral health status. Conventional dentures are the most common alternative in restoration of lost teeth. Without proper denture care practices, there is an increased risk of developing a multitude of problems. The aim of this study is to assess the denture care practices among complete denture wearers in East Godavari district, Andhra Pradesh. A cross-sectional study was conducted in the department of Prosthodontics at the Konaseema Institute of Dental Sciences, Amalapuram, Andhra Pradesh. Patients with self-care ability and adequate overall health who were using either single or full complete dentures for more than 6 months from the time of the study were requested to participate in the study. A total of 375 study participants were given a self-administered questionnaire on denture care practices followed by clinical examination of the denture status. Statistical analysis was done using the Statistical Package for the Social Sciences software for windows, version 20.0 (Armonk, NY: IBM Corp). The majority of participants reported cleansing their dentures once a day, with brush and water, and had the habit of removing the dentures at night. Almost 80% of the participants reported their denture status to be good/fair. Clinical examination revealed that slightly more than half of the participants had poor denture status. This study highlights the need for improvement in patient education and counseling with respect to the maintenance of dentures and upkeep of denture hygiene. It also emphasizes the need for educating patients on how to evaluate the status of their dentures.

  10. The attitude of complete denture wearers towards denture adhesives in Istanbul

    NARCIS (Netherlands)

    Ozcan, M.; Kulak, Y.; Arikan, A.; Silahtar, E.

    2004-01-01

    The purpose of using denture adhesives is to subjectively benefit denture-wearers with improved fit and comfort of their dentures and to improve their chewing ability and confidence. The purpose of this study was to investigate the approach and thought of complete denture wearers to denture adhesive

  11. The attitude of complete denture wearers towards denture adhesives in Istanbul

    NARCIS (Netherlands)

    Ozcan, M.; Kulak, Y.; Arikan, A.; Silahtar, E.

    2004-01-01

    The purpose of using denture adhesives is to subjectively benefit denture-wearers with improved fit and comfort of their dentures and to improve their chewing ability and confidence. The purpose of this study was to investigate the approach and thought of complete denture wearers to denture

  12. The attitude of complete denture wearers towards denture adhesives in Istanbul

    OpenAIRE

    Ozcan, M.; Kulak, Y.; ARIKAN, A.; Silahtar, E.

    2004-01-01

    The purpose of using denture adhesives is to subjectively benefit denture-wearers with improved fit and comfort of their dentures and to improve their chewing ability and confidence. The purpose of this study was to investigate the approach and thought of complete denture wearers to denture adhesives and to see why they had tried denture adhesive, and their reasons for its current use or non-use through a questionnaire. One hundred and fifteen patients attending the Marmara University, Dental...

  13. Evaluation of complete denture quality and masticatory efficiency in denture wearers.

    Science.gov (United States)

    Ribeiro, Jaiane Augusta Medeiros; de Resende, Camila Maria Bastos Machado; Lopes, Ana Lilian Correia; Mestriner, Wilson; Roncalli, Angelo Giuseppe; Farias-Neto, Arcelino; Carreiro, Adriana da Fonte Porto

    2012-01-01

    This study aimed to investigate (1) the influence of complete denture quality and years of denture use on masticatory efficiency and (2) the relationship between complete denture quality and years of use. A cross-sectional study was conducted with 93 edentulous patients (mean age: 65.6 years) wearing both mandibular and maxillary dentures. Patients were classified into two categories according to years of denture use: ≤ 2 years and ≥ 5 years. Masticatory efficiency was evaluated via the colorimetric method with beads as the artificial test food. A reproducible method for objective evaluation of the technical quality of complete dentures was employed. The association between denture quality and years of denture use was analyzed using chi-square and Fisher exact tests. The results of masticatory efficiency testing were analyzed using two-way analysis of variance (with the Tukey post hoc test) in terms of years of denture use (≤ 2 years, ≥ 5 years) and denture quality (poor, average, good). A significant relationship was found between denture quality and years of denture use (P denture use (0.101 ± 0.076 absorbance) and ≥ 5 years of use (0.068 ± 0.076 absorbance). Masticatory efficiency was not influenced by denture quality. Complete denture quality and masticatory efficiency significantly decreased over time. However, complete denture quality did not influence masticatory efficiency.

  14. [Occlusal vertical dimension in removable complete dentures].

    Science.gov (United States)

    den Haan, R; Witter, D J

    2011-12-01

    In removable complete dentures, the occlusal vertical dimension is an important factor for patients' satisfaction with aesthetics. An excessively reduced occlusal vertical dimension is especially likely to lead to complaints about aesthetics, whereas an increased occlusal vertical dimension may lead to discomfort and a decision not to wear the complete dentures. There are various methods for determining the occlusal vertical dimension in complete dentures, based on the vertical dimension in the rest position of the mandible or on phonetics. However, none of the methods have proven to be clearly superior, in terms of reliability, than the others. The assessment of the occlusal vertical dimension will become more reliable if several methods are used simultaneously. Moreover, knowledge of the characteristics of the ageing face is essential.

  15. [Gerontoprosthesis. Concept of rebuilding old complete dentures].

    Science.gov (United States)

    Marxkors, R; Mayer, K

    1990-04-01

    If aged patients who have been wearing their full dentures without complications so far, need further prothetic treatment, the dentist must not replace the old denture by a completely new one. It is better to rebuild it step by step. This demand is based on the following theses: --Nobody but the patient himself is able to perform functional movements. --Unless bite and occlusion are correct, patients are not able to perform accurate functional movements. --When bite and occlusion have been checked and, if necessary, improved, bases and alveolar ridges must be congruent.

  16. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  17. Proposed technique for fabricating complete denture

    Directory of Open Access Journals (Sweden)

    Abdulsalam Ali Zwiad

    2012-01-01

    Full Text Available Introduction: Reduction of the visits for fabricating complete dentures are welcomed by both dentists and patients and this might be an aspect of the new changes in prosthodontic treatment according to the suggested new methods. Clinical Innovation: Complete dentures fabricated by the technique described in this report reduce processing time, cost and efforts since the technique does not require the use of gypsum materials, metal flasks or other related materials to obtain a mold for packing the heat cured acrylic resin as might be needed with the conventional method. This method requires only an appropriate volume of silicone impression material to provide the required mold and a heat pressure machine for processing and polymerization of the heat-cured acrylic resin. Although this technique might be difficult to be applicable by all dentist but it could be consider an advisable method. Discussion: Because the record base in this technique is made of heat cured resin, it provides a reliable denture base with better retention and stability and it overcomes the shortcomings that may be faced during registration of vertical dimension. This technique meets the basic requirements for a successful complete denture which is well tolerated by the patient′s mouth.

  18. Dentist-Patient Communication and Denture Quality Associated with Complete Denture Satisfaction Among Taiwanese Elderly Wearers.

    Science.gov (United States)

    Chen, Jen-Hao; Huang, Hsiao-Ling; Lin, Ying-Chun; Chou, Tsau-Mau; Ebinger, John; Lee, Huey-Er

    2015-01-01

    The aim of this study was to explore individual (ie, sociodemographic characteristics, patient personality) and clinical factors (ie, dentist-patient communication, denture quality) associated with complete denture satisfaction among the Taiwanese elderly population. A multistage sampling and cross-sectional design was used to collect data. A total of 387 fully edentulous citizens, aged 65 years and older and who had received new sets of complete dentures, were selected. The participants completed clinical dental examinations and questionnaires by personal interview to collect information on denture satisfaction and associated variables. The relationship among three groups of these participants (satisfied, neutral, and dissatisfied) and potential factors were simultaneously examined using polytomous logistic regression analysis. Overall, 36.7% of the participants were dissatisfied with their dentures. Living status (crude odds ratio [COR] = 2.04), personality (COR = 4.86), dentist-patient communication (COR = 7.46), and denture quality (COR = 5.02) were associated with complete denture satisfaction. The multivariate regression model showed that dentist-patient communication (adjusted odds ratio [AOR] = 6.41) and denture quality (AOR = 4.40) were significant complete denture satisfaction factors that diluted the effect of living status and personality. Inadequate dentistpatient communication and low denture quality were associated with the dissatisfaction of patients with dentures. To increase complete denture satisfaction, the importance of training programs aimed at enhancing dentist-patient communication and denture quality cannot be overemphasized.

  19. [Complete removable dentures and prognathism].

    Science.gov (United States)

    Postaire, M; Raux, D

    1991-06-01

    Further to some reminders concerning terminology and resorption, this article presents the full denture prosthetic treatment for two patients with total edentation and a prognathic malocclusion. The first case presents a tridimensional symptomatology, described by: a progeny; a voluminous mandibular terrain; a concave profile; a rather closed mandibular angle; a mandible ridge which circumscribes the upper jaw; The particularities of the prosthetic treatment in this case are: a lowering of the posterior occlusal plane; a mounting of the teeth in a limited external position, that is to say, the maxillary lingual cuspids and the mandibular mesio-distal groove on the inter-crest line; the mandibular incisors and cuspids placed with a lingual inclination to obtain an edge-to-edge occlusal contact. The second case is of vertical symptomatology type, described by: a macrogeny; a moderate concavity of the profile; a very marked increase of the vertical dimension; an open mandibular angle; a short ramus; a long mandibule; a very marked overjet between the anterior crests. The particularities of the prosthetic treatment for this case are: a posterior teeth placement, avoiding cross-bite position, taken into account the strong convergence of the intercrest lines; a strong lingual inclination of the mandibular incisors and cuspids, in order to obtain an edge-to-edge occlusal contact. In the light of these two specific cases, emphasis is placed on the particularities of the treatment and on the teeth placement proposed in order to avoid any cross-bite teeth mounting.

  20. Photodynamic inactivation of microorganisms present on complete dentures. A clinical investigation. Photodynamic disinfection of complete dentures.

    Science.gov (United States)

    Ribeiro, Daniela Garcia; Pavarina, Ana Cláudia; Dovigo, Lívia Nordi; Mima, Ewerton Garcia de Oliveira; Machado, Ana Lucia; Bagnato, Vanderlei Salvador; Vergani, Carlos Eduardo

    2012-01-01

    The aim of this study was to evaluate the effectiveness of photodynamic therapy (PDT) for the disinfection of complete dentures. Biofilm samples were collected from dentures of 60 denture users who were randomly divided into four experimental groups (n = 15 each): subjects whose maxillary dentures were sprayed with 50 and 100 mg/l of Photogem® suspension (groups P50S and P100S) and patients whose maxillary dentures were treated with 50 and 100 mg/l of Photogem® gel (groups P50G and P100G). Dentures with photosensitizers were left in the dark for 30 min (pre-irradiation time) and then irradiated with blue LED light at 37.5 J/cm(2) (26 min). Denture samples were taken with sterile cotton swab before (left side surfaces) and after (right side surfaces) PDT. All microbial material was diluted and plated on selective media for Candida spp., Staphylococcus mutans spp., streptococci and a non-selective media. After incubation (48 h/37°C), the number of colony-forming units (cfu/ml) was counted. Microorganisms grown on selective media were identified using biochemical methods before and after PDT. The data were submitted to McNemar and Kruskal-Wallis tests (α = 0.05). No growth after PDT was observed in 60, 53, 47, and 40% of dentures from P100G, P50G, P100S, and P50S groups, respectively. When evidence of microorganisms' growth was observed, PDT regimens eliminated over 90% of microorganisms on dentures. This clinical study showed that PDT was effective for disinfecting dentures.

  1. Effectiveness of denture cleanser associated with microwave disinfection and brushing of complete dentures: in vivo study.

    Science.gov (United States)

    Sesma, Newton; Rocha, Alessandra Lima; Laganá, Dalva Cruz; Costa, Bruno; Morimoto, Susana

    2013-01-01

    Complete dentures acts as a reservoir for microbial colonization, which may lead to systemic infections. Microwave irradiation has been used as an efficient method of denture disinfection. Even though current methods eliminate denture-base microorganisms, a recurrence rate of denture stomatitis (DS) is still observed among denture-wearing patients. It was hypothesized that microwave disinfection kills microorganisms but do not remove dead bacteria from the denture surface. To test this hypothesis, the biofilm found in the dentures of 10 patients with DS was evaluated. In addition, the effects of microwave irradiation plus brushing (MW+B) on the denture biofilm and the combination of denture cleanser with microwave irradiation and brushing (MW+DC+B) for the removal of denture-accumulating microorganisms were investigated. Microbiological data were analyzed statistically by nonparametric analysis (Friedman/Wilcoxon, α=0.05). MW+B and MW+DC+B were effective in reducing the rate of microorganisms (99.2% and 99.5% respectively), but without significant difference between them (p=0.553). However, it was observed that the complete removal of microorganisms from denture surface was only possible when all regimens were combined (MW+DC+B). Microwave irradiation in combination with soaking in denture cleanser and brushing effectively disinfected the dentures and removed denture biofilm.

  2. Does Hollowing of Complete Denture Enhance Retention? - A Pilot Study.

    Science.gov (United States)

    Kalra, Ashish; Dhull, Kanika Singh; Iyer, Satish R; Mittal, Manish; Kalra, Shilpa; Yadav, Shweta

    2015-05-01

    Prosthetic rehabilitation is an extremely challenging task in extreme resorption cases of the maxillary denture-bearing area. Reducing the weight of a maxillary obturator has been seen as beneficial. But whether reducing the weight of conventional complete denture also increases retention or not, is still very dubious. The aim of this pilot study was to determine the effect of maxillary denture weight on denture retention and stability. For this study, a total of 10 patients were considered for the pilot study (06 female and 04 male) with an average age of 70 y. Each patient was provided with two sets of maxillary complete dentures, one hollow labeled as A and one conventional maxillary denture labeled as B. It was shown that mean values for retention using MKIS for retention for hollow dentures (A) was 7.8 and for conventional dentures (B) it was 8.2 and the stability for maxillary dentures was more with conventional dentures (B) than hollow maxillary dentures (A) and it was significant as p-value was 0.015 (pdenture retention and stability, chewing and comfort values of conventional dentures and hollow dentures were slightly better for conventional dentures.

  3. Clinical effects of acrylic resilient denture liners applied to mandibular complete dentures on the alveolar ridge.

    Science.gov (United States)

    Kimoto, S; Kimoto, K; Gunji, A; Kawai, Y; Murakami, H; Tanaka, K; Syu, K; Aoki, H; Toyoda, M; Kobayashi, K

    2007-11-01

    The purpose of this study was to investigate whether resilient denture liners has the potential to decrease problems affecting the alveolar ridge mucosa during the first adjustment session following the initial fitting of the denture. Interventions were complete denture treatment with permanent acrylic resilient denture liner dentures (RLD) in mandibles and conventional heat-activated acrylic resin dentures (ARD) in mandibles. Maxillary dentures were fabricated with conventional heat-activated ARD. Seventy-four subjects were randomly allocated to the RLD and ARD groups by random permuted blocks within the strata method after obtaining written informed consent. A randomized controlled parallel clinical trial with two hospital centres was conducted from April 2004 to July 2006. The problems were comprehensively evaluated by three outcomes with subjective and objective factors as follows: (i) numbers of sore spots, (ii) duration of wearing dentures and (iii) pain perception with 100 mm Visual Analog Scale. The numbers of sore spots in the mandibular support and border areas for the RLD group were significantly less than those for the ARD groups (P dentures an additional day longer than the ARD wearers (P denture liners to mandibular complete dentures provided edentulous patients with fewer problems affecting the alveolar during the first adjustment session following the initial fitting of the denture when compared with conventional denture treatments.

  4. Denture adhesive use in complete dentures: clinical recommendations and review of the literature.

    Science.gov (United States)

    Duqum, Ibrahim; Powers, Kendall Ann; Cooper, Lyndon; Felton, David

    2012-01-01

    This literature review sought to determine the advantages and disadvantages of denture adhesive use among complete denture patients. Manuscripts were obtained by searching the National Library of Medicine's PubMed database, Cochrane Collaboration Library, ADA Center for Evidence-Based Dentistry website, and EMBASE database. A total of 85 abstracts were reviewed, and 38 articles that met the inclusion criteria for this review were selected. The inclusion criteria included clinical trials and case series in which 10 or more patients were treated, as well as Cochrane collaboration reviews and in vitro studies where clinical relevance could be determined. The selected manuscripts were reviewed using a standardized manuscript review matrix. Although denture adhesives improve the retention and function of complete dentures, standardized guidelines are needed for the proper use, application, and removal of denture adhesives. Additionally, long-term studies are warranted on the biologic effects of denture adhesives. There is a need to establish a regular recall program for complete denture patients.

  5. An alternative technique for hollowing maxillary complete denture

    Directory of Open Access Journals (Sweden)

    Suryakant C Deogade

    2016-01-01

    Full Text Available Extreme resorption of edentulous maxilla may cause difficulty during fabrication of a maxillary complete denture. Increased inter-ridge distance often creates a clinical problem due to heavy-weighted maxillary prosthesis. This article elaborates an alternative approach for hollowing a maxillary complete denture. It utilizes a clear template of the trial denture facilitating the creation of a gelatin cavity form. This hollowing ensures the even thickness of both denture base resins for structural integrity and reduces the heaviness of the denture.

  6. Patients' perceptions of benefits and risks of complete denture therapy.

    Science.gov (United States)

    Miranda, Bárbara Barbério; Dos Santos, Mateus Bertolini Fernandes; Marchini, Leonardo

    2014-10-01

    The aim of this study was to assess patients' perceptions of benefits and risks concerning complete denture therapy. A secondary objective was to assess the influence of clinical and sociodemographic variables on patients' perceptions. The sample was composed of 104 volunteers who presented themselves for complete denture treatment at a dental school. The average age of the volunteers was 69.2 years (±) 9.3. Patient opinions concerning the benefits of complete denture therapy were recorded using a previously reported questionnaire. The answers were evaluated in three domains: (1) benefits (positive perceptions); (2) risks (negative perceptions); and (3) consequences of no treatment. The average time of use of the previous dentures was 20 years (SD ±12.9). Risk factors (negative perceptions) received lower scores by the patients, while the consequences of no treatment received higher scores. No association was found among evaluations of the previous dentures and educational level, marital status, and gender; however, patients' evaluation about their previous dentures was significantly different depending on age (p = 0.001) and previous dentures' time of use (p = 0.038). Patients presented a positive perception of complete denture therapy, and the risk factors (negative perceptions) received the lowest scores. Patient perception regarding complete denture therapy was not influenced by educational level, evaluation of the previous dentures, or marital status. © 2014 by the American College of Prosthodontists.

  7. Denture Hygiene Knowledge and Practices among Complete Denture Wearers attending a Postgraduate Dental Institute.

    Science.gov (United States)

    Shankar, Thatapudi; Gowd, Snigdha; Suresan, Vinay; Mantri, Sneha; Saxena, Sudhanshu; Mishra, Prateek; Panday, Pragya

    2017-08-01

    The aim of this study was to assess the denture hygiene knowledge and practices among patients using complete dentures attending a postgraduate dental hospital in Jabalpur city. The objective of this study was to assess the relationship between hygiene knowledge and practices to the denture wearer's gender, education, and income. A descriptive, cross-sectional survey was conducted using a self-administered questionnaire involving the complete denture patients attending the Department of Prosthodontics. The study subjects were randomly selected by recruiting old dentures wearers visiting the Department of Prosthodontics for a recall visit or for new dentures on the odd dates of the month. All subjects signed an informed consent before filling the questionnaire. The institutional review committee approved the study. Descriptive statistics included computation of frequencies and percentages. Nonparametric test, namely, chi-square test, was used for further data analysis; p-value dentures for more than 5 years. In this study, 51 (10.2%) subjects reported never having been advised by their dentists as to how to clean their dentures. Among all the subjects interviewed, 264 (52.8%) reported to clean the oral tissues daily. This study disclosed that 66 (13.2%) of the subjects usually slept with their dentures. Maximum subjects in illiterate group had experienced bad breath sometimes when compared with subjects in postgraduate group (χ(2) = 47.452, p denture cleaning according to gender (χ(2) = 101.076, p denture wearers have limited knowledge of denture cleansing and oral hygiene practices. Hygiene habits and practices may not always present a positive correlation with the gender, educational level, and income of the subjects. Periodic recall for evaluation of denture and mucosal surfaces along with reinforcement of denture hygiene instructions will go a long way in helping the patients reap maximum benefits out of their prostheses.

  8. Elderly complete denture wearers: a social approach to tooth loss.

    Science.gov (United States)

    Papadaki, Eftychia; Anastassiadou, Vassiliki

    2012-06-01

    To correlate emotional reactions to tooth loss with denture satisfaction attributes in elderly complete denture wearers. Total tooth loss is a serious life event, and poor oral health has an impact on daily life. Edentulism treated by rehabilitation with dentures can have a positive effect on patients' self-image and social behaviour. A group of 80 edentulous subjects undergoing routine prosthetic care in a Greek Department of Prosthetic Dentistry were interviewed using two structured questionnaires. The first questionnaire explored reactions to tooth loss, whereas the second measured their subjective experience of complete dentures. The responses to both questionnaires were compared using the statistical package SPSS v.17. The results showed significant correlation between aspects of tooth loss experience and complete denture satisfaction. Despite the fact that a substantial proportion of patients were satisfied with their complete dentures, some patients experienced increased social and psychological problems related to their edentulousness and the wearing of complete dentures. The aesthetic and functional aspects of complete dentures affected both patients' social behaviour and self-confidence. Total tooth loss was not only reflected in patient's social behaviour and self-image, but it had a complex and multifaceted impact on satisfaction from complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  9. Soft denture liners' effect on the masticatory function in patients wearing complete dentures: A systematic review.

    Science.gov (United States)

    Palla, Eleni Sotiria; Karaoglani, Eleni; Naka, Olga; Anastassiadou, Vassiliki

    2015-12-01

    To explore the effect of soft denture liners on the masticatory performance and muscle activity of edentulous patients wearing complete dentures, as determined by using objective measurement methods. Randomized controlled clinical trials and Cross-over studies that evaluated the masticatory capacity and muscle activity in denture wearers with and without soft denture liners were included in this systematic review. A comprehensive literature search was performed via electronic databases using the appropriate key words. The last search took place in September 2014. The potentially appropriate articles were identified and evaluated for eligibility through a predefined review process conducted by two examiners. Six out of the 176 identified records were included for quality and systematic assessment. The observed clinical and methodological diversity determined the narrative approach for the pooling of the findings. According to the studies brought together for the current systematic review, soft denture liners provided denture wearers with increased masticatory function compared to conventional denture base materials. Specifically, the use of long-term silicone liners significantly improved the mastication parameters. The observed intervention effects suggest further studies of higher quality to allow reliable conclusions to be drawn and to strengthen the clinical significance of these materials to patient's functionality. Soft denture lining materials have been suggested to address functional problems arising during complete denture function. This study was designed to systematically review the impact of soft liners' use on the masticatory efficiency in denture wearers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Effects of complete dentures on respiratory performance: spirometric evaluation.

    Science.gov (United States)

    Piskin, Bulent; Sipahi, Cumhur; Karakoc, Omer; Atay, Arzu; Ciftci, Faruk; Tasci, Canturk; Akin, Hakan; Arisan, Volkan; Sevketbeyoglu, Haldun; Turker, Turker

    2014-03-01

    There is a lack of data regarding whether edentulous subjects should remove dentures during spirometric measurements or not. The purpose of this study is to determine influences of complete dentures on spirometric parameters in edentulous subjects. A total of 46 complete denture wearers were included in this study. Respiratory functions of the subjects were evaluated by spirometric tests that were performed in four different oral conditions: without dentures (WOD), with dentures, lower denture only and upper denture only. Forced vital capacity (FVC), peak expiratory flow, forced expiratory volume in 1 s and forced expiratory flow between 25% and 75% were evaluated. The data were analyzed with Friedman, Wilcoxon and paired-samples t tests (α = 0.05). Significant differences were found between spirometric parameters in different oral conditions (p dentures (FVC), and WOD (forced expiratory volume in 1 s) and with upper dentures (forced expiratory volume in 1 s) (p complete dentures may unfavourably affect spirometric values of edentulous subjects. However, current findings need to be confirmed with advanced respiratory function tests. © 2012 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  11. Effect of Different Denture Base Materials and Changed Mouth Temperature on Dimensional Stability of Complete Dentures.

    Science.gov (United States)

    Arafa, Khalid A O

    2016-01-01

    Background. Type of materials used in fabrication of denture base has an effect on dimension during denture base material processing and other factors related to clinical use. Objective. The study aims were to assess the dimensional stability including thermal changes of three different denture base materials. Methods. Ninety patients were selected to construct complete dentures with different denture base materials. They were randomly divided into three groups: group 1, patients with cobalt chrome metallic base; group 2, patients with heat curing acrylic resin fabricated by injection moulding technique; and group 3, patients with denture bases fabricated by conventional heat curing acrylic resin. The dimensional changes were assessed using digital caliper. Results. After the twelfth month, injection moulding acrylic resin had significantly the highest dimensional change followed by the conventional heat curing acrylic resin. There were no significant differences in the dimensions between the three types of denture base materials at normal mouth temperature, while, after hot tea drinking at 45°C, the dimensional change was significantly the highest in cobalt chrome metallic denture base group. Conclusion. Cobalt chrome metallic denture base has stable dimension compared to denture bases fabricated of acrylic resin but it was more affected by altered mouth temperature. The study was registered in the International Standard Randomized Controlled Trials Number (ISRCTN) registry with study ID (ISRCTN94238244).

  12. Effect of Different Denture Base Materials and Changed Mouth Temperature on Dimensional Stability of Complete Dentures

    Directory of Open Access Journals (Sweden)

    Khalid A. O. Arafa

    2016-01-01

    Full Text Available Background. Type of materials used in fabrication of denture base has an effect on dimension during denture base material processing and other factors related to clinical use. Objective. The study aims were to assess the dimensional stability including thermal changes of three different denture base materials. Methods. Ninety patients were selected to construct complete dentures with different denture base materials. They were randomly divided into three groups: group 1, patients with cobalt chrome metallic base; group 2, patients with heat curing acrylic resin fabricated by injection moulding technique; and group 3, patients with denture bases fabricated by conventional heat curing acrylic resin. The dimensional changes were assessed using digital caliper. Results. After the twelfth month, injection moulding acrylic resin had significantly the highest dimensional change followed by the conventional heat curing acrylic resin. There were no significant differences in the dimensions between the three types of denture base materials at normal mouth temperature, while, after hot tea drinking at 45°C, the dimensional change was significantly the highest in cobalt chrome metallic denture base group. Conclusion. Cobalt chrome metallic denture base has stable dimension compared to denture bases fabricated of acrylic resin but it was more affected by altered mouth temperature. The study was registered in the International Standard Randomized Controlled Trials Number (ISRCTN registry with study ID (ISRCTN94238244.

  13. Efficacy of three denture brushes on biofilm removal from complete dentures

    Directory of Open Access Journals (Sweden)

    Roseana Aparecida Gomes Fermandes

    2007-02-01

    Full Text Available The aim of this study was to compare the efficacy of three denture brushes (Bitufo-B; Medic Denture-MD; Colgate-C on biofilm removal from upper and lower dentures using a specific dentifrice (Corega Brite. The correlation between biofilm levels on the internal and external surfaces of the upper and lower dentures was also evaluated. A microbiological assay was performed to assess the growth of colony-formed units (cfu of Candida yeasts on denture surface. Thirty-three patients were enrolled in a 10-week trial divided in two stages: 1 (control - three daily water rinses within 1 week; 2 - three daily brushings within 3 weeks per tested brush. Internal (tissue and external (right buccal flange surfaces of the complete dentures were disclosed (neutral red 1% and photographed. Total denture areas and disclosed biofilm areas were measured using Image Tool 3.00 software for biofilm quantification. Dentures were boxed with #7 wax and culture medium (CHROMagarTM Candida was poured to reproduce the internal surface. Statistical analysis by Friedman's test showed significant difference (p0.01. Analysis by the Correlation test showed higher r values (B=0.78; MD=0.8341, C=0.7362 for the lower dentures comparing the surfaces (internal and external and higher r values (B=0.7861, MD=0.7955, C=0.8298 for the external surface comparing the dentures (upper and lower. The results of the microbiological showed no significant difference (p>0.01 between the brushes with respect to the frequency of the species of yeasts (chi-square test. In conclusion, all denture brushes evaluated in this study were effective in the removal of biofilm. There was better correlation of biofilm levels between the surfaces for the lower dentures, and between the dentures for the external surface. There was no significant difference among the brushes regarding the frequency of yeasts.

  14. Do flexible acrylic resin lingual flanges improve retention of mandibular complete dentures?

    Science.gov (United States)

    Ahmed Elmorsy, Ayman Elmorsy; Ahmed Ibraheem, Eman Mostafa; Ela, Alaa Aboul; Fahmy, Ahmed; Nassani, Mohammad Zakaria

    2015-01-01

    The aim of this study was to compare the retention of conventional mandibular complete dentures with that of mandibular complete dentures having lingual flanges constructed with flexible acrylic resin "Versacryl." The study sample comprised 10 completely edentulous patients. Each patient received one maxillary complete denture and two mandibular complete dentures. One mandibular denture was made of conventional heat-cured acrylic resin and the other had its lingual flanges made of flexible acrylic resin Versacryl. Digital force-meter was used to measure retention of mandibular dentures at delivery and at 2 weeks and 45 days following denture insertion. The statistical analysis showed that at baseline and follow-up appointments, retention of mandibular complete dentures with flexible lingual flanges was significantly greater than retention of conventional mandibular dentures (P dentures, retention of dentures increased significantly over the follow-up period (P complete dentures improved denture retention.

  15. The effectiveness of chemical denture cleansers and ultrasonic device in biofilm removal from complete dentures.

    Science.gov (United States)

    Cruz, Patrícia Costa; Andrade, Ingrid Machado de; Peracini, Amanda; Souza-Gugelmin, Maria Cristina Monteiro de; Silva-Lovato, Cláudia Helena; de Souza, Raphael Freitas; Paranhos, Helena de Freitas Oliveira

    2011-01-01

    Adequate denture hygiene can prevent and treat infection in edentulous patients. They are usually elderly and have difficulty for brushing their teeth. This study evaluated the efficacy of complete denture biofilm removal using chemical (alkaline peroxide-effervescent tablets), mechanical (ultrasonic) and combined (association of the effervescent and ultrasonic) methods. Eighty complete denture wearers participated in the experiment for 21 days. They were distributed into 4 groups (n=20): (1) Brushing with water (Control); (2) Effervescent tablets (Corega Tabs); (3) Ultrasonic device (Ultrasonic Cleaner, model 2840 D); (4) Association of effervescent tablets and ultrasonic device. All groups brushed their dentures with a specific brush (Bitufo) and water, 3 times a day, before applying their treatments. Denture biofilm was collected at baseline and after 21 days. To quantify the biofilm, the internal surfaces of the maxillary complete dentures were stained and photographed at 45º. The photographs were processed and the areas (total internal surface stained with biofilm) quantified (Image Tool 2.02). The percentage of the biofilm was calculated by the ratio between the biofilm area multiplied by 100 and the total area of the internal surface of the maxillary complete denture. The Kruskal-Wallis test was used for comparison among groups followed by the Dunn multiple-comparison test. All tests were performed respecting a significance level of 0.05. Significant difference was found among the treatments (KW=21.18; Pcomplete dentures.

  16. 2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition.

    Science.gov (United States)

    Ikeya, Kenji; Fukunishi, Miya; Iwasa, Fuminori; Inoue, Yuuki; Ishihara, Kazuhiko; Baba, Kazuyoshi

    2016-12-26

    Removable dentures made of poly (methyl methacrylate) (PMMA) are prone to bacterial adherence and dental plaque formation, which is called denture plaque. Denture plaque-associated infection is a source of serious dental and medical complications in the elderly. 2-Methacryloyloxyethyl phosphorylcholine (MPC) is a well-known biomedical material that exhibits marked antithrombogenicity and tissue compatibility because of its high resistance to protein adsorption and cell adhesion. Therefore, MPC polymer coatings are suggested to have the potential to inhibit plaque deposition on the surface of PMMA dentures. However, coating MPC polymer on the surface of a PMMA denture is a complex procedure that requires specialized equipment, which is regarded as a major barrier to its clinical application. Here, we introduce a new MPC polymer treatment procedure that uses poly (MPC-co-BMA-co-MPAz) (PMBPAz) to prevent denture plaque deposition on removable dentures. This procedure enables the MPC coating of PMMA denture surfaces in a simple and stable manner that is resistant to various chemical and mechanical stresses due to the MPC layer of PMBPAz that is covalently bound to the PMMA surface by ultraviolet light irradiation. In addition, the procedure does not require any specialized equipment and can be completed by clinicians within 2 min. We applied this procedure in a clinical setting and demonstrated its clinical utility and efficacy in inhibiting plaque deposition on removable dentures.

  17. Cognitive status of edentate elders wearing complete denture: Does quality of denture matter?

    Science.gov (United States)

    Cerutti-Kopplin, Daiane; Emami, Elham; Hilgert, Juliana Balbinot; Hugo, Fernando Neves; Padilha, Dalva Maria Pereira

    2015-09-01

    Emerging evidence suggests that an individual's level of mastication may play a role in their cognitive status. This suggests that in edentate individuals wearing complete denture, non-optimal mastication via inadequate denture could be related to cognitive status. To examine the impact of quality of denture on cognitive status of a sample of elderly edentate Brazilian individuals wearing complete denture. This study is a cross-sectional analysis of data collected from 117 edentate elders (mean age 73.7 ± 5.6 years) wearing complete denture, in southern Brazil. Cognitive impairment was assessed using the Brazilian version of the mini-mental state examination (MMSE). Clinical examination was conducted to evaluate the quality of dentures by use of the FAD (functional assessment of dentures) instrument. Masticatory ability was assessed by self-reported questions. The mean MMSE score for the total sample was 23.1 (SD=4.4) and was associated with age (p=0.001), education (pdentures (pdentures in maintaining cognitive activity in elders. This association may be explained via mastication pathway. The potential beneficial effect of functional dentures on cognitive status via mastication could encourage preventive strategies to decrease substantial risk of morbidity in elders. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Not chewing food among the Thai elderly with complete denture.

    Science.gov (United States)

    Viwatwongkasem, Chukiat; Kudngaongarm, Romanee; Chaisupamongkollarp, Somchai; Thamsoonthorn, Chanida; Naovaratsophon, Anchalee; Nipattasat, Prapon; Vichathai, Weeranun; Pakdethanakul, Chaweewan; Jareinpituk, Suthi; Satitvipawee, Pratana

    2013-12-01

    The study aims to investigate the use of a complete denture in terms of not chewing food and determining the strength of association between not chewing food and several potential risk factors among the Thai elderly. Under the support of the "Khao Aroi" or "Delicious Rice" or "Dental Implant" Project of Institute of Dentistry, Department of Medical Services, Ministry of Public Health, and in co-operation with the Ministry of Science and Technology during 2007-2011, a cross-sectional survey by multi-stage cluster sampling was conducted in 2008, in 21 provinces, 87 hospitals, with 2,676 Thai elderly. The sample was drawn from a sampling frame of 58,043 target Thai people aged 60 years and over under the Dental Prosthesis Service Campaign (DPSC) project during 2005 and 2007. All Thai elderly, who received a complete denture from the DPSC project at least three months prior were surveyed from May to October 2008 through questionnaires. Data were analyzed by a set of descriptive analyses and binary logistic regression models. Not chewing food among the Thai elderly, after receiving a complete denture, was 12.5%, quite a bit more effective than ordinary work. Nontaluck found 38% for the proportion not wearing dentures in the 30-baht health care program. This finding is confirmed by the work of Dalodom et al that the use of dentures by Thai elderly was 93% in the DPSC project. The important risk factors that influenced not to chew food were satisfaction with dentures, patients satisfaction with the denture fitting and care, while controlling the amount of dentures, respectively. Satisfaction of patients with their dentures, good oral health care in fitting denture work, and good communication between dentists and patients are important keys affecting the use of dentures.

  19. Effectiveness of microwave disinfection of complete dentures on the treatment of Candida-related denture stomatitis.

    Science.gov (United States)

    Neppelenbroek, K H; Pavarina, A C; Palomari Spolidorio, D M; Sgavioli Massucato, E M; Spolidorio, L C; Vergani, C E

    2008-11-01

    The effectiveness of microwave disinfection of maxillary complete dentures on the treatment of Candida-related denture stomatitis was evaluated. Patients (n = 60) were randomly assigned to one of four treatment groups of 15 subjects each; patients performed the routine denture care; Mw group: patients had their upper denture microwaved (650 W per 6 min) three times per week for 30 days; group MwMz: patients received the treatment of Mw group in conjunction with topical application of miconazole three times per day for 30 days; group Mz: patients received the antifungal therapy of group MwMz. Cytological smears and mycological cultures were taken from the dentures and the palates of all patients before treatment at day 15 and 30 of treatment and at follow-up (days 60 and 90). The effectiveness of the treatments was evaluated by Kruskal-Wallis and Mann-Whitney tests. Microbial and clinical analysis of the control group demonstrated no significant decrease in the candidal infection over the clinical trial. Smears and cultures of palates and dentures of the groups Mw and MwMz exhibited absence of Candida at day 15 and 30 of treatment. On day 60 and 90, few mycelial forms were observed on 11 denture smears (36.6%) from groups Mw and MwMz, but not on the palatal smears. Miconazole (group Mz) neither caused significant reduction of palatal inflammation nor eradicated Candida from the dentures and palates. Microwaving dentures was effective for the treatment of denture stomatitis. The recurrence of Candida on microwaved dentures at follow-up was dramatically reduced.

  20. The Relationship between Temporomandibular Disorders (TMDs and Overall Denture Conditions in Complete Denture Wearers

    Directory of Open Access Journals (Sweden)

    Fatemeh Rostamkhani

    2015-06-01

    Full Text Available Introduction: The aim of this study was to investigate whether there is any relationship between the condition of complete dentures and TMDs. Methods: The sample consisted of 61 consecutive patients (35 females and 26 males who were admitted to the Department of Prosthodontics of Mashhad Faculty of Dentistry for fabrication of new complete dentures.  The age range of the participants was between 32 and 80 years, with the mean age of 57.05±10.26 years. The patients were examined by two prosthodontists. Using a questionnaire, the first prosthodontist asked the patients about their habits and history of trauma to the temporomandibular joints (TMJs. She then examined the participants for signs and symptoms of temporomandibular disorders (TMDs.  The second prosthodontist examined each participant's existing denture and checked its fit, stability, retention, occlusion, and centric relation, and recorded how long it had been in service. The examination was double blind. The data were recorded in examination sheets. Results: The relationship between TMDs and denture fit, stability, retention, centric relation and occlusion was analyzed using Fisher’s Exact Test. No significant relationship was found between denture characteristics and TMDs in complete denture wearers (P-value>0.05. Conclusion: Complete denture characteristics did not play a role in the development of TMDs in edentulous patients.

  1. Complete denture analyzed by optical coherence tomography

    Science.gov (United States)

    Negrutiu, Meda L.; Sinescu, Cosmin; Todea, Carmen; Podoleanu, Adrian G.

    2008-02-01

    The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative systems and procedures were imagined, directly related to the material used and also to the manufacturing technology. Thus, at the present time, there are several injecting systems and technologies on the market, that use chemoplastic materials, which are heat cured (90-100°C), in dry or wet environment, or cold cured (below 60°C). There are also technologies that plasticize a hard cured material by thermoplastic processing (without any chemical changes) and then inject it into a mold. The purpose of this study was to analyze the existence of possible defects in several dental prostheses using a non invasive method, before their insertion in the mouth. Different dental prostheses, fabricated from various materials were investigated using en-face optical coherence tomography. In order to discover the defects, the scanning was made in three planes, obtaining images at different depths, from 0,01 μm to 2 mm. In several of the investigated prostheses we found defects which may cause their fracture. These defects are totally included in the prostheses material and can not be vizualised with other imagistic methods. In conclusion, en-face OCT is an important investigative tool for the dental practice.

  2. Masticatory Function of Subjects Rehabilitated with Conventional Complete Denture

    Directory of Open Access Journals (Sweden)

    Marisa Martins da Silva PRADO

    2006-09-01

    Full Text Available Objective: Evaluate masticatory function of subjects rehabilitated with conventional complete denture, considered adequate or good (index of Kapur, by means of objective and subjective tests and to verify influence of quality and denture time use. Method: Masticatory performance tests (MP, using test food Optocal, had been carried through with 20 and 40 chewing strokes in 21 subjects with complete denture (group CD and 15 with natural dentition (group ND. Masticatory performance index was taken by means of the calculation of the Average Geometric Diameter of chewed and sifted particles. Results: After analysis statistics (Tukey b, p<0.05, observed that group CD obtainable 12% and 31% of the performance reached for group ND subjects, after 20 and 40 strokes, respectively, being that literature quantifies masticatory performance from 20% to 30% of the natural dentition. Statistical significant differences (t-test student, p<0.05 between MP and masticatory ability had not been verified, as well as denture quality of group CD. In relation to denture use period, users with more than six months had obtainable better resulted, possibly for being more adapts to the denture. Conclusion: In the limit of this study, it could be possible conclude that complete dentures users considered adequate or good had improved its MP after use six months. Standing out that with 20 strokes, in test food related, the result (12% was worst to in literature described.

  3. Fabricating complete dentures with CAD/CAM technology.

    Science.gov (United States)

    Infante, Luis; Yilmaz, Burak; McGlumphy, Edwin; Finger, Israel

    2014-05-01

    Conventional complete denture prosthetics require several appointments to register the maxillomandibular relationship and evaluate the esthetics. The fabrication of milled complete dental prostheses with digital scanning technology may decrease the number of appointments. The step-by-step method necessary to obtain impressions, maxillomandibular relation records, and anterior tooth position with an anatomic measuring device is described. The technique allows the generation of a virtual denture, which is milled to exact specifications without the use of conventional stone casts, flasking, or processing techniques.

  4. The effectiveness of chemical denture cleansers and ultrasonic device in biofilm removal from complete dentures

    Directory of Open Access Journals (Sweden)

    Patrícia Costa Cruz

    2011-12-01

    Full Text Available Adequate denture hygiene can prevent and treat infection in edentulous patients. They are usually elderly and have difficulty for brushing their teeth. OBJECTIVE: This study evaluated the efficacy of complete denture biofilm removal using chemical (alkaline peroxide-effervescent tablets, mechanical (ultrasonic and combined (association of the effervescent and ultrasonic methods. MATERIAL AND METHODS: Eighty complete denture wearers participated in the experiment for 21 days. They were distributed into 4 groups (n=20: (1 Brushing with water (Control; (2 Effervescent tablets (Corega Tabs; (3 Ultrasonic device (Ultrasonic Cleaner, model 2840 D; (4 Association of effervescent tablets and ultrasonic device. All groups brushed their dentures with a specific brush (Bitufo and water, 3 times a day, before applying their treatments. Denture biofilm was collected at baseline and after 21 days. To quantify the biofilm, the internal surfaces of the maxillary complete dentures were stained and photographed at 45º. The photographs were processed and the areas (total internal surface stained with biofilm quantified (Image Tool 2.02. The percentage of the biofilm was calculated by the ratio between the biofilm area multiplied by 100 and the total area of the internal surface of the maxillary complete denture. RESULTS: The Kruskal-Wallis test was used for comparison among groups followed by the Dunn multiple-comparison test. All tests were performed respecting a significance level of 0.05. Significant difference was found among the treatments (KW=21.18; P<0.001, the mean ranks for the treatments and results for Dunn multiple comparison test were: Control (60.9; Chemical (37.2; Mechanical (35.2 and Combined (29.1. CONCLUSION: The experimental methods were equally effective regarding the ability to remove biofilm and were superior to the control method (brushing with water. Immersion in alkaline peroxide and ultrasonic vibration can be used as auxiliary agents

  5. Assessment of Candida species colonization and denture-related stomatitis in complete denture wearers.

    Science.gov (United States)

    Zomorodian, Kamiar; Haghighi, Neda Nejabat; Rajaee, Naeem; Pakshir, Keyvan; Tarazooie, Bita; Vojdani, Mahroo; Sedaghat, Farzaneh; Vosoghi, Mehrdad

    2011-02-01

    Candida species are considered the primary causative agents of denture stomatitis, but their role in colonization and disease in denture wearers remains undefined. In this study, we investigated risk factors associated with progression to Candida-related denture stomatitis in patients using complete dentures, and we genetically identified Candida isolates associated with disease and colonization. We recruited 114 retirement home residents for this study, from whom oral mucosa samples were collected and cultured following oral cavity exams. Morphologic analysis was used to identify potential yeast-positive cultures, which were then characterized further by RFLP analysis. C. albicans was the most frequently recovered species (61; 41.5%), followed by C. glabrata (27; 18.4%), and C. tropicalis (19; 12.9%). In addition, 16 isolates (10.9%) of C. dubliniensis were recovered, which was the first identification of this species in clinical samples from Iran. This study demonstrated a significant association between the duration of denture wear and oral candidiasis. Furthermore, we noted a high prevalence of C. dubliniensis in complete denture wearers.

  6. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    NARCIS (Netherlands)

    Polyzois, G.L.; Baat, C. de

    2012-01-01

    OBJECTIVE: To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. BACKGROUND: There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. MATERIALS AND METHODS:

  7. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    NARCIS (Netherlands)

    Polyzois, G.L.; Baat, C. de

    2012-01-01

    OBJECTIVE: To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. BACKGROUND: There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. MATERIALS AND METHODS: Th

  8. Simplified Complete Denture: A Systematic Review of the Literature.

    Science.gov (United States)

    Ye, Ye; Sun, Jian

    2017-06-01

    Many procedures are used to construct traditional (T) complete dentures; however, a simplified (S) method requiring fewer steps and less time is available. This systematic review intends to summarize the modeling of simplified methods for complete dentures and evaluate the differences between the T method and S method. With this review, we hope to lay the foundation for proposing a standardized fabrication method for "simplified dentures." The MEDLINE (via PubMed) and EMBASE databases were searched for articles on simplified complete dentures published in English before April 2014. Eleven articles were included. One was about one-step complete dentures, two were about SET (simplified treatment of edentulous patients), and the others were about the normal simplified method, which includes impression, occlusal registration, and try-in. Seven were randomized controlled clinical trials (RCTs). The time, cost, patient satisfaction, clinical effects, masticatory performance, masticatory ability, and professional evaluation reported in these studies were compared. We summarized the different techniques of fabricating complete dentures and discussed the RCTs of the normal complete technique. None of the RCTs identified significant differences between the S and T groups in terms of patient ratings for general satisfaction, OHIP-edentulous scale, denture quality, or masticatory ability. At the same time, the T method was significantly more expensive and required more time to complete than the S method. Current scientific evidence suggests that the S method can replace or partly replace the T method. Moreover, specific rules should be devised to restrict the simplified construction, and detailed research should be conducted. © 2016 by the American College of Prosthodontists.

  9. The influence of patient characteristics on acrylic-based resilient denture liners embedded in maxillary complete dentures.

    Science.gov (United States)

    Ogawa, Akina; Kimoto, Suguru; Saeki, Hiroyuki; Ono, Masanori; Furuse, Nobuhiko; Kawai, Yasuhiko

    2016-07-01

    A major complication associated with the use of resilient denture liners (RDLs) is a change in hardness over time. In vivo studies on the deterioration of RDLs over time are needed. We aimed to investigate the influence of patient characteristics on the hardness of acrylic-based RDLs (ARDLs) embedded in complete maxillary dentures. We hypothesized that 1 month after application of the ARDLs, the hardness would be influenced by age, saliva condition, occlusal force, smoking, drinking, denture wearing during sleeping, denture cleanser usage, and denture type. Thirty complete maxillary denture wearers were recruited after obtaining informed consent. One investigator measured the Shore D hardness of the commercially available ARDLs, Soften (SFT), FD Soft (FDS), and Bio Liner (BIO) using a Vesmeter(®). The salivary flow rates and pH values and the occlusal force were measured for all patients before initiation of the study. T-tests and Pearson's correlation coefficients were used for the statistical analyses. A p-value of dentures while sleeping, use of denture cleansers, and denture type were associated with an increase in the hardness of the RDLs. The resting saliva pH only influenced the hardness of the SFT ARDLs. Smoking, denture wearing while sleeping, denture cleanser usage, denture type, and resting saliva pH are important predictors of the deterioration of ARDLs over time. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. The Relationship between Temporomandibular Disorders (TMDs) and Overall Denture Conditions in Complete Denture Wearers

    OpenAIRE

    2015-01-01

    Introduction: The aim of this study was to investigate whether there is any relationship between the condition of complete dentures and TMDs. Methods: The sample consisted of 61 consecutive patients (35 females and 26 males) who were admitted to the Department of Prosthodontics of Mashhad Faculty of Dentistry for fabrication of new complete dentures.  The age range of the participants was between 32 and 80 years, with the mean age of 57.05±10.26 years. The patients were examined by two prosth...

  11. An alternative approach in fabrication of fixed complete dentures using a duplicate denture.

    Science.gov (United States)

    Afshari, Fatemeh S; Hallas, Matthew B; Knoernschild, Kent L

    2012-10-01

    The traditional prosthetic steps in the fabrication of a fixed complete denture after implant osseointegration include final impression, verification of implant positioning in the working cast, mounting of the working cast, and mock denture wax trial insertion prior to the laboratory fabrication of the metal substructure; however, in patient scenarios of immediate loading of implants, the interim conversion prosthesis can be used to advance from the final impression to the milling of the underlying framework in one appointment. Consistency in the initial wax trial insertion, radiographic guide, and intraoral positioning of the conversion prosthesis can result in a well-designed definitive prosthesis in less time with the use of the existing duplicate complete denture. © 2012 by the American College of Prosthodontists.

  12. Effects of home and office care denture reliners on maxillary complete dentures.

    Science.gov (United States)

    Udo-Yamakawa, Aiko; Kawai, Yasuhiko

    2010-06-01

    The aim of this study was to evaluate the effects of office (OR) and home (HR) care temporary denture reliners on satisfaction and functional outcomes in maxillary complete denture wearers. Thirty-four maxillary edentulous patients received application of either OR or HR to their maxillary complete dentures. Patient's ratings on satisfaction and functional aspects were measured on a 100-mm visual analogue scale at 4 days post-application. Associations between baseline ratings and improvement were also assessed. There were no significant differences between the two groups in satisfaction ratings or in the functional outcomes. The OR group showed a significant improvement in mastication and retention, whereas the HR group exhibited a significant improvement in general satisfaction and mastication. Improvement was negatively associated with baseline ratings of speech, ease of cleaning, stability and retention in the OR groups and across all variables, except ease of cleaning, in the HR group. When used correctly, home care denture therapy can be as effective as office applied temporary liner in improving satisfaction with problematic maxillary dentures.

  13. Inhibition of denture plaque deposition on complete dentures by 2-methacryloyloxyethyl phosphorylcholine polymer coating: A clinical study.

    Science.gov (United States)

    Ikeya, Kenji; Iwasa, Fuminori; Inoue, Yuuki; Fukunishi, Miya; Takahashi, Nana; Ishihara, Kazuhiko; Baba, Kazuyoshi

    2017-05-12

    Denture plaque-associated infections are regarded as a source of serious dental and medical complications in the elderly population. Methods of managing this problem are needed. The purpose of this clinical study was to evaluate the effects of treatment with a 2-methacryloyloxyethyl phosphorylcholine polymer, PMBPAz, on plaque deposition in complete dentures. The study protocol was approved by the Ethics Committee of Showa University (#2013-013). Eleven individuals with maxillary complete dentures participated in this study. Their dentures were treated with PMBPAz, and the amount of denture plaque accumulation was evaluated by staining the denture surfaces with methylene blue after 2 weeks of denture usage. The same procedures were repeated to evaluate the original denture surfaces as a control. The image of the stained denture surface was captured using a digital camera, and the percentage of stained area, quantified as a pixel-based density, of the whole denture area (percentage of plaque index) was calculated for the mucosal and polished surfaces. To quantify the biofilm on the dentures, denture plaque biofilm was detached by ultrasonic vibration, resuspended in diluent, and measured with a microplate reader at an optical density of 620 nm. The effects of PMBPAz treatment on these variables were statistically analyzed with ANOVA (α=.05). The mean ±SD percentage of plaque index was 40.7% ±19.9% on the mucosal surfaces and 28.0% ±16.8% on the polished surfaces of the control denture. The mean percentage of plaque index of PMBPAz-treated dentures significantly decreased to 17.4%% ±12.0% on the mucosal surfaces (Pcomplete dentures. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Tongue pressure recordings during speech using complete denture

    CERN Document Server

    Jeannin, Christophe; Payan, Yohan; Dittmar, André; Grosgogeat, Brigitte

    2008-01-01

    This paper describes an original experimental procedure to measure mechanical interactions between tongue and teeth during speech production. Using edentulous people as subjects, pressure transducers are inserted in their complete denture duplicate. Physiology is respected during sound and pressure recording as with standard complete denture. Original calibration device is also described in order to know what kind of information can be extracted from the data. The measurements are realized in different experimental conditions in order to remove the auditory and the orosensory feedbacks. Then the first results of the pilot study are presented

  15. Anticandidal efficacy of denture cleansing tablet, Triphala, Aloe vera, and Cashew leaf on complete dentures of institutionalized elderly.

    Science.gov (United States)

    Shetty, Pooja J; Hegde, Vijaya; Gomes, Leslie

    2014-01-01

    With an increase in the number of dependent elderly, there is a need to introduce few natural products for denture cleansing, which are easily and economically available. Hence the aim of this study was to compare the anticandidal efficacy of denture cleansing tablet (sodium bicarbonate and sodium perborate monohydrate), Triphala (Phyllanthus emblica, Terminalia chebula and Terminalia belerica fruits powders in equal proportion), cashew leaf, Aloe vera and water (control) on complete dentures of institutionalized elderly. Study population consisted of 50 institutionalized elderly of Mangalore, Karnataka, with 10 in each group. Swabs were collected from the dentures before and after the use of denture cleansing tablet, Triphala, cashew leaf, Aloe vera, and water (control). Thereafter, the swabs were cultured on Sabouraud dextrose agar and the total candida counts were determined. Denture cleansing tablet and Triphala Churna showed a statistically significant reduction in Candida counts (P Denture cleansing tablet and Triphala Churna were found to be more effective.

  16. A randomised controlled trial of complete denture impression materials.

    Science.gov (United States)

    Hyde, T P; Craddock, H L; Gray, J C; Pavitt, S H; Hulme, C; Godfrey, M; Fernandez, C; Navarro-Coy, N; Dillon, S; Wright, J; Brown, S; Dukanovic, G; Brunton, P A

    2014-08-01

    There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7-67.3%, pUnilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. [Three dimensional changes of the denture base of the complete denture following polymerization].

    Science.gov (United States)

    Takahashi, Y

    1990-02-01

    The objective of this study was to clarify some of the dimensional change patterns of the denture base of the complete denture following polymerization. Dimensional changes of three polymerization method types were compared. The complete dentures were measured by using the three dimensional measurement system. The results obtained were summarized as follows. 1. Dimensional changes from the original model immediately after polymerization of complete upper and lower dentures were recorded and all three polymerization methods produced shrinkage on all three axes toward the center. Heat cured resin samples and microwave cured resin samples showed the same shrinkage with pour type resin samples only showing 1/2 that amount. 2. The gradual dimensional changes occurring after polymerization up until 4 weeks were also recorded. The heat cured resin samples showed no additional changes but remained in its shrunken state. The pour-type resin samples began to enlarge until almost all of them reached the original model size within 4 weeks. The microwave cured resin samples began to enlarge but only slightly and then soon stopped changing. 3. All polymerization method types showed more dimensional change in the lower plate than in the upper plate.

  18. Reservoir Complete Denture in a Patient with Xerostomia ...

    African Journals Online (AJOL)

    In edentulous patients, one method of using these salivary substitutes is ... complete denture are costly, time consuming and require extra‑laboratory steps. Therefore, the ... obtained for the agreed treatment, which included rehabilitation of the upper ... rims with the centric records were preserved and set aside for later use.

  19. IMPROVDENT: improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures.

    Science.gov (United States)

    Gray, Janine C; Navarro-Coy, Nuria; Pavitt, Sue H; Hulme, Claire; Godfrey, Mary; Craddock, Helen L; Brunton, Paul A; Brown, Sarah; Dillon, Sean; Dukanovic, Gillian; Fernandez, Catherine; Wright, Jonathan; Collier, Howard; Swithenbank, Shirley; Lee, Carol; Hyde, T Paul

    2012-08-31

    According to the UK Adult Dental Health Survey (2009) 15% of adults aged 65-74, 30% aged 75-84 and 47% aged >85 years are edentulous and require complete dentures. Patients' quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone). Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period). Patients will then wear each set of dentures for a period of 8 weeks (in random order) during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period).Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference) and confirmation period (adjusted denture preference). A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300). This trial aims to provide evidence on the costs and quality of dentures

  20. Improvdent: Improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures

    Directory of Open Access Journals (Sweden)

    Gray Janine C

    2012-08-01

    Full Text Available Abstract Background According to the UK Adult Dental Health Survey (2009 15% of adults aged 65–74, 30% aged 75–84 and 47% aged >85 years are edentulous and require complete dentures. Patients’ quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. Methods/Design IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone. Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period. Patients will then wear each set of dentures for a period of 8 weeks (in random order during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period. Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference and confirmation period (adjusted denture preference. A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. Funding: IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300. Discussion

  1. A Randomised Controlled Trial of complete denture impression materials

    Science.gov (United States)

    Hyde, T.P.; Craddock, H.L.; Gray, J.C.; Pavitt, S.H.; Hulme, C.; Godfrey, M.; Fernandez, C.; Navarro-Coy, N.; Dillon, S.; Wright, J.; Brown, S.; Dukanovic, G.; Brunton, P.A.

    2014-01-01

    Objectives There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Methods Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Results Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7–67.3%, p silicone impressions were preferred by patients. Clinical significance Given the strength of the clinical findings within this paper, dentists should consider choosing silicone rather than alginate as their material of choice for secondary impressions for complete dentures. Trial Registration: ISRCTN 01528038.

 This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. PMID:24995473

  2. Computerized cephalometric evaluation of changes following treatment with complete dentures

    Directory of Open Access Journals (Sweden)

    Strajnić Ljiljana

    2012-01-01

    Full Text Available The aim of this study was to provide longitudinal evaluation of the changes after complete dentures therapy and the rate of residual ridge resorption through a six-year period of denture wearing. The authors presented the case of a 76-year-old patient, edentulous for twelve years, wearing complete dentures for six years, with the eugnat jaw relationship. Cephalometric radiograph was carried out in the process of new complete denture production, while the evaluation was carried out after six years. Cephalometric analysis was performed by using ”Dr. Ceph” computer software (FYI Technologies, GA, USA. After six years, the reduction of anterior total facial height was 5.5 mm and the anterior lower facial height was 5.5 mm, the vertical residual ridge reduction of the maxilla was 1.4 mm and the reduction of the mandible was 3mm. The study confirms the reliability and advantages of cephalometric analyses and reveals their application possibilities in prosthetic diagnostics and therapy, as well as in evaluation of rehabilitative results in edentulous patients and longitudinal analysis of changes on the orofacial complex tissues and intemaxillary relationships.

  3. Reestablishment of Occlusal Vertical Dimension in Complete Denture Wearing in Two Stages

    Directory of Open Access Journals (Sweden)

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available The assessment and reestablishment of the occlusal vertical dimension (OVD are considered important factors in the treatment of complete denture wearers. The long-time use of a complete denture can result in jaw displacement due to abrasion of the artificial teeth and residual ridge resorption, causing esthetic complications. Most patients with old dentures and incorrect OVD accept reestablishment of the OVD with new complete dentures, even if they were used to their old dentures. The present clinical report describes a method of gradual reestablishment of OVD using a diagnostic acrylic splint on artificial teeth in old complete dentures before the manufacture of new complete dentures. Clinical Significance. The use of a reversible treatment for reestablishment of the OVD in old complete dentures with a diagnostic occlusal acrylic splint allows for the reestablishment of the intermaxillary relationship, providing physiological conditions of masticatory performance associated with the recovery of facial esthetics in edentulous patients.

  4. Reestablishment of Occlusal Vertical Dimension in Complete Denture Wearing in Two Stages.

    Science.gov (United States)

    Marin, Danny Omar Mendoza; Leite, Andressa Rosa Perin; de Oliveira Junior, Norberto Martins; Compagnoni, Marco Antonio; Pero, Ana Carolina; Arioli Filho, João Neudenir

    2015-01-01

    The assessment and reestablishment of the occlusal vertical dimension (OVD) are considered important factors in the treatment of complete denture wearers. The long-time use of a complete denture can result in jaw displacement due to abrasion of the artificial teeth and residual ridge resorption, causing esthetic complications. Most patients with old dentures and incorrect OVD accept reestablishment of the OVD with new complete dentures, even if they were used to their old dentures. The present clinical report describes a method of gradual reestablishment of OVD using a diagnostic acrylic splint on artificial teeth in old complete dentures before the manufacture of new complete dentures. Clinical Significance. The use of a reversible treatment for reestablishment of the OVD in old complete dentures with a diagnostic occlusal acrylic splint allows for the reestablishment of the intermaxillary relationship, providing physiological conditions of masticatory performance associated with the recovery of facial esthetics in edentulous patients.

  5. Functional Impressions in Complete Denture and Overdenture Treatment

    OpenAIRE

    2015-01-01

    Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fabrica...

  6. On the clinical deformation of maxillary complete dentures. Influence of denture-base design and shape of denture-bearing tissue.

    Science.gov (United States)

    el Ghazali, S; Glantz, P O; Strandman, E; Randow, K

    1989-04-01

    This paper aimed to study the influence of denture base design and the shape of the denture-supporting area on the functional deformation of maxillary complete dentures. Six strain-gauged duplicate maxillary dentures were made for the study of two test subjects with different shapes of the palatal vault. Each subject was supplied with two polymethyl methacrylate dentures, one with a 1-mm-thick palatal base and the other 2 mm thick. A third denture was constructed with a cobalt-chromium base. The functional loading tests included maximum biting and the chewing of the food test samples. An analysis based on chewing time and total number of chewing cycles per test piece was also made. The results showed that surface straining is highly complex at the anterior part of the maxillary dentures constructed from polymethyl methacrylate and that increasing the denture thickness per se might not be accompanied by a reduction of strain. The results also suggest that high thrust to the supporting tissue is produced with high palatal vault dentures made in polymethyl methacrylate. The study proposes that cobalt-chromium bases may be used in maxillary dentures to reduce functional deformation and thrust to the supporting tissues at the anterior part of the maxilla.

  7. Does Hollowing of Complete Denture Enhance Retention? – A Pilot Study

    Science.gov (United States)

    Kalra, Ashish; Iyer, Satish R; Mittal, Manish; Kalra, Shilpa; Yadav, Shweta

    2015-01-01

    Introduction Prosthetic rehabilitation is an extremely challenging task in extreme resorption cases of the maxillary denture-bearing area. Reducing the weight of a maxillary obturator has been seen as beneficial. But whether reducing the weight of conventional complete denture also increases retention or not, is still very dubious. The aim of this pilot study was to determine the effect of maxillary denture weight on denture retention and stability. Materials and Methods For this study, a total of 10 patients were considered for the pilot study (06 female and 04 male) with an average age of 70 y. Each patient was provided with two sets of maxillary complete dentures, one hollow labeled as A and one conventional maxillary denture labeled as B. Results It was shown that mean values for retention using MKIS for retention for hollow dentures (A) was 7.8 and for conventional dentures (B) it was 8.2 and the stability for maxillary dentures was more with conventional dentures (B) than hollow maxillary dentures (A) and it was significant as p-value was 0.015 (pdenture retention and stability, chewing and comfort values of conventional dentures and hollow dentures were slightly better for conventional dentures. PMID:26155561

  8. Simplified versus comprehensive fabrication of complete dentures: patient ratings of denture satisfaction from a randomized crossover trial.

    Science.gov (United States)

    Heydecke, Guido; Vogeler, Michael; Wolkewitz, Martin; Türp, Jens C; Strub, Joerg R

    2008-02-01

    To determine if patient ratings of their ability to chew are dependent on the method of complete denture fabrication. Twenty edentulous patients participated in a randomized within-subject crossover trial. Each participant received 2 sets of new complete dentures. One pair (Gerber prosthesis) was manufactured based on tracings (to determine centric relation) and facebow transfer; semianatomic teeth with a lingualized and balanced occlusal pattern were used. The other set of complete dentures was made using a simplified procedure without facebow transfer; jaw relations were recorded with wax occlusion rims, and anatomic teeth were set with a canine and premolar guidance (Gysi prosthesis). The 2 dentures were delivered in randomized order, and each was worn for 3 months. Three months after insertion, patients' ratings of each new prosthesis were obtained on visual analog scales for general satisfaction, comfort, ability to speak, stability, esthetics, ease of cleaning, and ability to chew. Patients rated their general satisfaction, stability, and esthetic appearance significantly better for the Gysi prostheses ( P denture treatment methods were detected for ability to speak, comfort, chewing ability, and the ease of cleaning the dentures. A comprehensive method for the fabrication of complete dentures using lingualized teeth does not appear to positively influence patient ratings of denture satisfaction when compared to a simple procedure with anatomic teeth.

  9. Comparative Study of Acceptance and Adaptation to New Complete Dentures, Using Two Construction Protocols.

    Science.gov (United States)

    Kamalakidis, Savvas N; Anastassiadou, Vassiliki; Sofou, Afrodite; Pissiotis, Argirios L

    2016-10-01

    To validate patients' acceptance and adaptation to new complete dentures, fabricated using two construction protocols. Evaluation was achieved by means of two psychometric questionnaires and registration of total number of sore spots. Twenty complete denture wearers, who sought replacement dentures because of complaints (material degradation or unsatisfactory repaired fracture) associated with them, were selected according to specific inclusion criteria. The denture construction protocols were randomly assigned to the study participants. Ten participants received complete dentures using a duplication construction protocol with a bilateral balanced occlusal (BBO) scheme (duplicate complete denture group); ten participants received complete dentures using a traditional construction protocol with BBO (traditional complete denture group). All study participants completed the Complete Denture Satisfaction and the Oral Health Impact Profile-20 (OHIP-20) questionnaires before they received the new complete dentures (pretreatment) and at 3 and 6 months post-treatment. At the initial adaptation/adjustment visits, the location and number of sore spots were identified. Statistical analysis was performed to evaluate differences between groups and within each group pre- and post-treatment. Denture satisfaction and oral health related quality of life scores were independent of the complete denture construction protocol. Within the traditional complete denture group there was a statistically significant increase in denture satisfaction and equivalent decrease (improvement) in OHIP-20 scores between pre- and post-treatment (both at 3-month and 6-month visits). This finding was consistent for OHIP-20 scores within the duplicate complete denture group, but not for denture satisfaction, which was not statistically significant. The total number of recorded sore spots was approximately double for the traditional complete denture group compared to the duplicate complete denture group

  10. Use of a complete denture as a radiation carrier

    Energy Technology Data Exchange (ETDEWEB)

    Herring, H.W. Jr.; Greene, P.E.

    1983-06-01

    When surgical resection of intraoral neoplasms is contraindicated, treatment by surface mold irradiation may be used. Success or failure of this mode of treatment may depend on the fabrication of a surface mold that can deliver the prescribed amount of therapeutic radiation in the desired amount of time. A technique for modification of an existing complete denture prosthesis for use as a surface mold has been described. Patient cooperation is essential for successful use of this modified prosthesis.

  11. A microbiological evaluation of the use of denture cleansers in combination with an oral rinse in complete denture patients

    Directory of Open Access Journals (Sweden)

    Srinivasan Murali

    2010-01-01

    Full Text Available Background and Aim : Patients with complete dentures more occasionally neglect their denture and oral health by improper maintenance of dentures, resulting in bad oral and denture hygiene. This may lead to a host of multiple local and systemic problems such as stomatitis, bacterial and fungal infections, reservoirs for distant infections, denture stains and bad breath. Most denture wearers maintain their dentures with simple manual cleansing methods, which are not adequate to effectively sanitize the reservoir of microorganisms inhabiting the denture surfaces. The aim of this study was to compare the efficacy of the use of a denture cleanser and compare it with an adjunct use of chlorhexidine mouth rinse along with the denture cleanser and possibly suggest it as a suitable protocol. Materials and Methods : Two groups of complete denture patients were selected for the study. The total number of patients in each group was 12 and the total period of the study was 21 days. Three sets of microbiological samples were collected from each patient: before the start of the study, on day 8 and on day 21 of the study. The first sample was collected after an initial washover period (7 days with plain water before the start of the study and the second set after 1 week of study initiation, where group-1 followed protocol-I (denture cleanser only and group-2 followed protocol-II (denture cleanser and mouth rinse. A second washout period of 7 days followed and a crossover of the protocol was performed for the groups and followed for 1 week. Then, a third set of samples were collected. The colony-forming units were calculated for each patient for each sample and statistically analyzed. Friedman test for non-parametric analysis was employed for the comparison within the groups and a Mann-Whitney test was used for the statistical comparison between the groups. Results : There was a definite reduction in the bacterial numbers and a significant statistical difference

  12. Effect of Cast Modification on Denture Base Adaptation Following Maxillary Complete Denture Processing.

    Science.gov (United States)

    Sayed, Mohammed E; Porwal, Amit; Ehrenberg, David; Weiner, Saul

    2017-01-19

    To investigate the effect of cast modifications on denture base adaptation in coronal and sagittal projections following maxillary complete denture processing. A total of 60 edentulous maxillary casts (n = 10) were distributed among six groups. Group 1 was the control group with no modification, groups 2 through 6 included a butterfly postdam preparation, groups 3 and 4 also included a 10-mm wide/4-mm deep box with addition of four round holes in group 4, and groups 5 and 6 also included a 20-mm wide/4-mm deep box with addition of four round holes in group 6. The boxes were prepared at the mid-heel area of the casts. Two layers of baseplate wax (1 mm each) were used to standardize denture base thickness across the groups. A standard technique was used to replicate the denture tooth set-up, and standardized processing was done for all the groups. Following deflasking, casts with the dentures were sectioned in the coronal and sagittal directions. Microscopic pictures were taken at preselected points. Data were organized in tables, and statistical analyses were performed using repeated measure ANOVA, Tukey post hoc tests, and post hoc comparison tests set at 5% level of significance. Maximum gaps were measured at the mid-palatal area followed by nearby areas and the areas near ridge crests in both coronal and sagittal projections. The analyses revealed significant differences between the groups in coronal projection (1/2, 3/4, 5/6) and sagittal projection (1, 2, 3/4, 5/6) without significant differences within the pairs. The groups were ranked from the highest group 1 to the lowest group 6 relative to the gap means. Post hoc comparisons showed that points 1C and 2A had the highest gap means across the study groups. Within the limitations of this study, it can be extrapolated that the denture base adaptation can be effectively increased with the box preparation at the mid-heel aspect of the casts. Significant reduction of gaps was seen when the box size increased from

  13. Complete denture wearing and fractures among edentulous patients treated in university clinics.

    Science.gov (United States)

    Takamiya, Aline S; Monteiro, Douglas R; Marra, Juliê; Compagnoni, Marco A; Barbosa, Debora B

    2012-06-01

    The prevalence of wearing and fracture of complete dentures was evaluated among edentulous patients treated in two dental schools in Brazil. Acceptance and wearing of complete dentures are related to adaptive behaviour of edentulous patients. However, one reason that could interfere with the wearing dentures is their potential to fracture, which is still a common complication in denture rehabilitation practice. Two hundred and twenty-four edentulous patients rehabilitated with complete dentures from 2000 to 2005 in Araçatuba and Araraquara Dental School, University of State of São Paulo, were assessed in 2006 and 2007 to answer a questionnaire about wearing and fracture of their dentures. Statistical analysis were performed using Epi Info software and chi-squared test to compare maxillary and mandibular data (α = 0.05). Almost 26% of the patients did not wear their dentures, and among the remainder, the majority wore the maxillary denture. About 30% of the dentures were fractured, with higher prevalence in the maxillary arch (p = 0.003). Discontinuation of wearing dentures was quite high, especially considering the treatment which was carried out in university clinics. Prevalence of fractures was also high, greater for the maxillary denture, and was one of the main reasons for non-wearing of complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  14. Spectrogram Analysis of Complete Dentures with Different Thickness and Palatal Rugae Materials on Speech Production

    Directory of Open Access Journals (Sweden)

    Hamada Zaki Mahross

    2015-01-01

    Full Text Available Objective. To investigate the influence of reproduction of different thickness and palatal rugae materials on complete dentures speech using Computerized Speech Lab (CSL (spectrogram. Materials and Methods. Three completely edentulous male patients (aged 50–60 years were selected for reading a paragraph. Twelve upper dentures were constructed, four for each patient. The patients’ speech groups were divided into five groups, Group I: patients without dentures; Group II: patients rehabilitated with conventional acrylic dentures; Group III: patients with conventional acrylic dentures with rugae reproduction; Group IV: patients with dentures with metallic framework of minimal thickness and direct ragged metallic palatal surface at rugae area; Group V: patients with dentures with palatal rugae constructed from resilient acrylic resin material with thickness less than conventional denture. Speech samples were recorded after insertion of each denture for groups using Computerized Speech Lab (CSL (spectrogram. The sounds selected were lingopalatal /s/z/sh/t/d/ and /l/. Results. Group III produced high mean significant difference with /sh/t/ sound. For Group IV, the difference was noticed with /s/z/sh/t/ and /d/ sounds, while for Group V the difference was shown with /z/l/ sound (P<0.05. Conclusion. It is recommended to reproduce the rugae area in complete denture because the phonetic quality of complete denture with rugae is superior to the conventional denture.

  15. Video-based Learning Versus Traditional Method for Preclinical Course of Complete Denture Fabrication

    Directory of Open Access Journals (Sweden)

    Amir Fayaz

    2015-03-01

    Full Text Available Statement of the Problem: Advances in computer science and technology allow the instructors to use instructional multimedia programs to enhance the process of learning for dental students. Purpose: The purpose of this study was to determine the effect of a new educa-tional modality by using videotapes on the performance of dental students in preclinical course of complete denture fabrication. Materials and Method: This quasi-experimental study was performed on 54 junior dental students in Shahid Beheshti University of Medical Sciences (SBMU. Twenty-five and 29 students were evaluated in two consecutive semesters as controls and cases, respectively for the same course. The two groups were matched in terms of "knowledge about complete denture fabrication" and "basic dental skills" using a written test and a practical exam, respectively. After the intervention, performance and clinical skills of students were assessed in 8 steps. Eventually, a post-test was carried out to find changes in knowledge and skills of students in this regard. Results: In the two groups with the same baseline level of knowledge and skills, independent T-test showed that students in the test group had a significantly superior performance in primary impression taking (p= 0.001 and primary cast fabrication (p= 0.001. In terms of anterior teeth set up, students in the control group had a significantly better performance (p= 0.001. Conclusion: Instructional videotapes can aid in teaching fabrication of complete denture and are as effective as the traditional teaching system.

  16. Digitally planned and fabricated mandibular fixed complete dentures. Part 2. Prosthodontic phase.

    Science.gov (United States)

    Kattadiyil, Mathew T; Goodacre, Charles J; Lozada, Jaime L; Garbacea, Antoanela

    2015-01-01

    Part 1 of this patient report described a prosthetically driven protocol that used computer-aided engineering for the fabrication of a mandibular conversion denture and maxillary provisional complete denture using the AvaDent Digital Denture system. The report demonstrated that this system combined with NobelClinician implant-planning software can be used to efficiently convert a digital denture into an immediately loaded provisional implant-supported fixed complete denture (hybrid prosthesis). Part 2 of the patient report describes the technique and steps involved in the fabrication of a digitally planned and fabricated mandibular fixed complete denture with incorporated titanium milled bar opposed by a definitive computer-aided design/computer-assisted manufacture-milled maxillary complete denture.

  17. Survival analysis of mandibular complete dentures with acrylic-based resilient liners.

    Science.gov (United States)

    Kimoto, Suguru; Kimoto, Katsuhiko; Murakami, Hiroshi; Gunji, Atsuko; Ito, Nana; Kawai, Yasuhiko

    2013-09-01

    The purpose of this long-term randomised controlled trial was to compare the longevity of dentures constructed using a conventional acrylic resin (CAR) to that of dentures constructed using an acrylic-based resilient liner (ARL). The follow-up study was essentially carried out by annual telephone calls to each of the 67 participants. The Kaplan-Meier method and life-table analysis were used for univariate analyses. The Cox proportional-hazards test was used as a final model for statistically adjusting predictor variables such as sex, clinician type, mandibular denture type and age at denture delivery. The denture type was likely to affect the survival time of the dentures, while the sex and clinician type were not. The group using acrylic-based resilient denture liners had twice the risk of having shorter denture-survival times than those using conventional acrylic resin dentures. Younger participants were likely to have a reduced risk of having shorter denture-survival times than older participants. We conclude that mandibular complete dentures constructed using ARL are twice as likely as dentures constructed using CAR to have shorter denture survival times, mainly because of material deterioration. © 2012 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  18. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    Science.gov (United States)

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2016-11-21

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  19. The oral health-related quality of life in edentulous patients treated with conventional complete dentures.

    Science.gov (United States)

    Albaker, Abdulaziz M

    2013-03-01

    To compare the oral health-related quality of life (OHRQoL) between patients with both maxillary and mandibular complete denture and those with either the maxillary or the mandibular complete denture. Satisfaction of denture wearers can be estimated using the OHRQoL questionnaires like the OHIP-EDENT and the Geriatric Oral Health Assessment Index (GOHAI). Two questionnaires were used to compare the OHRQoL between edentulous patients who had conventional removable complete denture on both jaws and those who had on either one of the jaws. The age of the participants ranged from 42 to 75 years, with the mean age of 58 ± 8.12 years. The mean OHIP-EDENT scores were significantly high among those who wore conventional dentures in both jaws (54.12 ± 5.21), compared with the participants who only had denture either on upper or lower jaw (46.52 ± 7.35). It was noticed that the mean GOHAI score was significantly lower (p denture on both upper and lower jaw (28.25 ± 3.67), as compared to those who had conventional denture only on one arch (35.12 ± 2.11). Patients with complete dentures in both jaw (Group I) were less satisfied than patients with single complete denture (Group II). The result obtained in this study shows dissatisfaction with conventional dentures among edentulous patients. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  20. Photoelastic analysis of stresses transmitted by complete dentures lined with hard or soft liners.

    Science.gov (United States)

    Pereira, Izabella P; Consani, Rafael L X; Mesquita, Marcelo F; Nóbilo, Mauro A A

    2015-10-01

    Stresses transmitted on the alveolar bone ridge by lined conventional complete mandibular dentures can decrease the bone absorption level. The aim of this in vitro study was to evaluate the stresses induced on the alveolar bone ridge of lined conventional complete mandibular dentures by using photoelastic analysis. One maxillary and three mandibular conventional dentures were developed for the following treatments: 1 - Unlined denture (control), 2 - Denture lined with resin-based material, and 3 - Denture lined with silicone-based material. The photoelastic analysis took place with the dentures in the position of maximum intercuspation, and the mandibular photoelastic models were axially loaded with 10 kgf (98 N). Unlined denture (control) presented stresses along the model, especially on the anterior and left lateral sides with less stresses on the right side. On the left lateral side, the denture base lined with resin-based material demonstrated similar stresses to that of the control; however, lower stresses occurred in the premolar and retromolar regions. Denture bases lined with silicone-based material showed decreased fringe orders and homogeneous distribution of induced stresses. Both lined dentures exhibited lower stresses when compared to unlined dentures. Silicone-based material provided a more homogeneous distribution of stresses. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. The relationship between various parameters of complete denture quality and patients' satisfaction.

    Science.gov (United States)

    Alfadda, Sara A

    2014-09-01

    Patients' appreciation of their conventional complete dentures might be affected by the quality of the dentures. A random sample of 33 edentulous patients who were rehabilitated by means of conventional complete dentures participated in the study. Three independent investigators who underwent technique calibration evaluated the dentures on the basis of seven clinical criteria by using a validated examination form. The patients filled out a validated denture satisfaction scale. The author used Pearson product-moment correlation and analysis of covariance to identify possible correlations. The study results showed that most patients were between "reasonably satisfied" and "very satisfied" with their dentures. The author found nominally higher satisfaction among those receiving both mandibular and maxillary dentures and significant positive correlations between the overall denture satisfaction score and the stability of the mandibular denture (P = .039) and retention of the mandibular denture (P = .005). In contrast, esthetic lip support and lower lip line, occlusion, and maxillary stability and retention were not correlated with participants' overall satisfaction level (P > .064). The results of this study show that a clinically stable mandibular denture was the most important determinant of patients' satisfaction. The study findings highlight the most important denture quality parameters that can aid clinicians in meeting their patients' expectations.

  2. Evaluation of Prevalence of Oral Candidiasis in Patients Using Complete Denture Wears

    Directory of Open Access Journals (Sweden)

    P Tavakkol

    2001-06-01

    Full Text Available Denture stomatotos os a common problem of the denture wears, and its etiology is not clear from the literatures. Some studies show that the aetiology is candida albicans, while other reports point out the other agents including candida albicans. The present study was designed to evaluate the prevalence of oral candidiasis in patients using complete denture with different datas. 50 subjects all wearing complete denture participated in this study. The palatal mucosa was swabbed and swabs were cultured in Sabourauds medium containing 0.005% chloramphenicol then cultures were tested with common mycological lab tests. In 80% of patients oral candidiasis have been diagnosed. In the investigation a direct relation between the oral candidiasis and removal of denture at night, denture cleanliness, presence of any suction and symptoms of denture stomatitis was shown. No relation between the oral candidiasis and sex, smoking habit, succeptible disease, angular cheilitis; the recent condition of denture and the retention of denture were found. The findings of our investigation indicates that candida albicans is the causative agent of denture stomatitis while other factors such as denture cleanliness, removal of denture at night and presence of any suction may be considered as well.

  3. The influence of mandibular ridge anatomy on treatment outcome with conventional complete dentures.

    Science.gov (United States)

    Ribeiro, Jaiane A M; de Resende, Camila M B M; Lopes, Ana L C; Farias-Neto, Arcelino; Carreiro, Adriana da F P

    2014-01-01

    Since prognostic indicators are likely to take on increasing importance as a diagnostic tool for selection of patients for implant provision, this study investigated the influence of the shape and resiliency of the mandibular alveolar ridge on the retention and stability of conventional complete dentures. Ninety- three edentulous patients wearing both maxillary and mandibular conventional complete dentures composed the sample. Data were collected regarding shape and resiliencyof the mandibular residual ridge. Dentures were assessed for retention and stability using an objective and reproducible tool.The associations between the clinical characteristics of the mandibular alveolar ridge and denture retention and stability were analyzed using chi-square and Fisher exact tests (a = 0.05). A significant association between ridge shape and denture stability (p denture retention (p complete dentures.

  4. Different types of antagonists modify the outcome of complete denture renewal.

    Science.gov (United States)

    Berteretche, Marie Violaine; Frot, Amélie; Woda, Alain; Pereira, Bruno; Hennequin, Martine

    2015-01-01

    The effect of renewing removable dentures on masticatory function was evaluated according to the occlusion offered by different types of mandibular arches. Twenty-eight patients with complete maxillary dentures were subdivided into three groups in terms of mandibular dentition type: dentate, partial denture, and complete denture. The participants were observed before and 8 weeks after maxillary denture renewal. The mandibular denture was also renewed in the partial and complete denture groups. The participants masticated carrots, peanuts, and three model foods of different hardnesses. The particle size distribution of the boluses obtained from natural foods was characterized by the median particle size (d50) in relation to the masticatory normative indicator (MNI). Chewing time (CT), number of chewing cycles (CC), and chewing frequency (CF) were video recorded. A self-assessment questionnaire for oral health-related quality of life (Geriatric Oral Health Assessment Index [GOHAI]) was used. Statistical analyses were carried out with a mixed model. Renewal of the dentures decreased d50 (P Denture renewal improves masticatory function. The complete denture group benefited least from renewal; the dentate group benefited most. This study confirmed the usefulness of denture renewal for improving functions and oral health- related quality of life.

  5. A Simplified Technique to Measure Plaque on the Intaglio Surfaces of Complete Dentures.

    Science.gov (United States)

    Almas, Khalid; Salameh, Ziad; Kutkut, Ahmad; Al Doubali, Ahmad

    2015-04-01

    The main aim of this study was to develop a simplified quantitative denture plaque index that could help dentists to motivate denture patients to maintain optimal oral hygiene. The secondary aim was to assess specific areas of dentures more prone to accumulate plaque and subjects' oral hygiene habits related to their dentures. One hundred subjects who wore maxillary and/or mandibular complete dentures for at least one year were included in the study as a powered sample. Fifteen females and 85 males, age range 45-75 years, were recruited. The study was carried out at King Saud University (KSU), College of Dentistry. A plaque disclosing solution was used to assess the plaque covered areas of denture. A quantitative percentage (10 x 10%) score index was developed by assessing plaque scores from digital images of intaglio surfaces of the dentures. The weighted kappa method was used to assess inter-examiner agreement in the main study. The new denture plaque index was identified as ASKD-DPI (Almas, Salameh, Kutkut, and Doubali-Denture Plaque Index). It ranged from 0 - 100%, and reflected the percentage of the intaglio surfaces of maxillary and mandibular complete dentures that contained plaque. It also classified quantitative percentages: 30 subjects ranged from 0 - 30% (low DPI), 50 subjects ranged from 31 - 70% (moderate DPI), and 20 subjects ranged from 71 - 100% (high DPI) denture plaque score. A simplified denture plaque index (ASKD-DPI) technique was developed and tested in this study. ASKD-DPI may be used for evaluating denture plaque scores, monitoring denture hygiene, and measuring compliance of patients regarding plaque control for complete dentures.

  6. Knowledge and Self Perception among Dental Students (Interns) about Procedures Involved in Complete Denture Fabrication

    National Research Council Canada - National Science Library

    S Swathy; Ashish R Jain; M D A C U Varma

    2017-01-01

    .... Introduction Fabrication of complete dentures include various steps that include primary impression making, border moulding, final impression, laboratory procedures, jaw relation, teeth selection...

  7. Design and fabrication of complete dentures using CAD/CAM technology

    Science.gov (United States)

    Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686

  8. Design and fabrication of complete dentures using CAD/CAM technology.

    Science.gov (United States)

    Han, Weili; Li, Yanfeng; Zhang, Yue; Lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures.The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures.Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures.Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM.

  9. Complete denture wear during sleep in elderly sleep apnea patients--a preliminary study.

    Science.gov (United States)

    Almeida, Fernanda R; Furuyama, Ricardo Jun; Chaccur, Danilo Chucralla; Lowe, Alan A; Chen, Hui; Bittencourt, Lia Rita; Frigeiro, Maria L M A; Tsuda, Hiroko

    2012-09-01

    There is no consensus in the literature about the impact of complete denture wear on obstructive sleep apnea (OSA). The goal of this randomized clinical study was to assess if complete denture wear during sleep interferes with the quality of sleep. Elderly edentulous OSA patients from a complete denture clinic were enrolled and received new complete dentures. An objective sleep analysis was determined with polysomnography performed at the sleep laboratory for all patients who slept either with or without their dentures. Twenty-three patients (74% females) completed the study with a mean age of 69.6 years and a mean body mass index of 26.7 kg/m(2). The apnea and hypopnea index (AHI) was significantly higher when patients slept with dentures compared to without (25.9 ± 14.8/h vs. 19.9 ± 10.2/h; p > 0.005). In the mild OSA group, the AHI was significantly higher when patients slept with the dentures (16.6 ± 6.9 vs. 8.9 ± 2.4; p dentures (.30.8 ± 15.6 vs. 25.7 ± 7.5; p = 0.2). The supine AHI in mild patients was related to a higher increase in AHI while wearing dentures (12.7 ± 8.4/h vs. 51.9 ± 28.6/h; p dentures showed an increase in their AHI while wearing dentures to sleep. Contrary to previous studies, we found that OSA patients may experience more apneic events if they sleep with their dentures in place. Specifically, in mild OSAS patients, the use of dentures substantially increases the AHI especially when in the supine position.

  10. Biomechanical factors related to occlusal load transfer in removable complete dentures.

    Science.gov (United States)

    Żmudzki, Jarosław; Chladek, Grzegorz; Kasperski, Jacek

    2015-08-01

    Owing to economic conditions, removable dentures remain popular despite the discomfort and reduced chewing efficiency experienced by most denture wearers. However, there is little evidence to confirm that the level of mucosal load exceeds the pressure pain threshold. This discrepancy stimulated us to review the current state of knowledge on the biomechanics of mastication with complete removable dentures. The loading beneath dentures was analyzed in the context of denture foundation characteristics, salivary lubrication, occlusal forces, and the biomechanics of mastication. The analysis revealed that the interpretation of data collected in vivo is hindered due to the simultaneous overlapping effects of many variables. In turn, problems with determining the pressure beneath a denture and analyzing frictional processes constitute principal limitations of in vitro model studies. Predefined conditions of finite element method simulations should include the effects of oblique mastication forces, simultaneous detachment and sliding of the denture on its foundation, and the stabilizing role of balancing contacts. This review establishes that previous investigations may have failed because of their unsubstantiated assumption that, in a well-working balanced occlusion, force is only exerted perpendicular to the occlusal plane, allowing the denture to sit firmly on its foundation. Recent improvements in the simulation of realistic biomechanical denture behavior raise the possibility of assessing the effects of denture design on the pressures and slides beneath the denture.

  11. The effect of a commercial probiotic drink on oral microbiota in healthy complete denture wearers

    Science.gov (United States)

    Sutula, Justyna; Coulthwaite, Lisa; Thomas, Linda; Verran, Joanna

    2012-01-01

    Background It is acknowledged that oral and general health status declines with age. The global population of denture wearers is increasing, so is the incidence of denture biofilm-related problems, such as denture-associated stomatitis, aspiration pneumonia and malodour. It has been suggested that consumption of probiotic bacteria may improve oral health. However, the effects of probiotics on the oral microbiota of denture wearers have received little attention. Methods The aim of this study was to investigate the effect of consumption of a commercial probiotic product (Yakult) on microbiota of saliva, tongue and denture biofilm in healthy complete denture wearers. Eight healthy complete denture-wearing National Health Service (NHS) patients undertook a 7-week trial comprising three phases: baseline; 4-week consumption of one bottle of Yakult per day, each containing a minimum 6.5×109 viable cells of Lactobacillus casei strain Shirota (LcS); 4-week washout period. The microbial viability and composition of saliva, tongue dorsum coating and denture biofilm were assessed using a range of solid selective and indicator media. Questionnaires were used to explore participants’ denture cleaning habits and impact of wearing dentures on their life quality and well-being [modified oral health impact profile (OHIP-14)] prior to and after the study. Results Seven volunteers (1 male, 6 females) completed the trial. LcS temporarily colonised oral cavity and denture surface. There was no significant change in the viability of Streptococcus mutans, acidogenic microorganisms, total anaerobic species and Gram-negative obligate anaerobes between study phases. There was no obvious effect of LcS on occurrence and viability of Candida. Participants presented a good general knowledge of denture hygiene and their responses to OHIP-14 questionnaires improved after completing the study (p=0.16). Conclusion It appeared that 4-week consumption of probiotic drink had no overall effect on

  12. The effect of a commercial probiotic drink on oral microbiota in healthy complete denture wearers

    Directory of Open Access Journals (Sweden)

    Justyna Sutula

    2012-10-01

    Full Text Available Background : It is acknowledged that oral and general health status declines with age. The global population of denture wearers is increasing, so is the incidence of denture biofilm-related problems, such as denture-associated stomatitis, aspiration pneumonia and malodour. It has been suggested that consumption of probiotic bacteria may improve oral health. However, the effects of probiotics on the oral microbiota of denture wearers have received little attention. Methods : The aim of this study was to investigate the effect of consumption of a commercial probiotic product (Yakult on microbiota of saliva, tongue and denture biofilm in healthy complete denture wearers. Eight healthy complete denture-wearing National Health Service (NHS patients undertook a 7-week trial comprising three phases: baseline; 4-week consumption of one bottle of Yakult per day, each containing a minimum 6.5×109 viable cells of Lactobacillus casei strain Shirota (LcS; 4-week washout period. The microbial viability and composition of saliva, tongue dorsum coating and denture biofilm were assessed using a range of solid selective and indicator media. Questionnaires were used to explore participants’ denture cleaning habits and impact of wearing dentures on their life quality and well-being [modified oral health impact profile (OHIP-14] prior to and after the study. Results : Seven volunteers (1 male, 6 females completed the trial. LcS temporarily colonised oral cavity and denture surface. There was no significant change in the viability of Streptococcus mutans, acidogenic microorganisms, total anaerobic species and Gram-negative obligate anaerobes between study phases. There was no obvious effect of LcS on occurrence and viability of Candida. Participants presented a good general knowledge of denture hygiene and their responses to OHIP-14 questionnaires improved after completing the study (p=0.16. Conclusion : It appeared that 4-week consumption of probiotic drink had

  13. Comparison of the retention strengths of three complete denture adhesives: an in vivo study.

    Science.gov (United States)

    Mañes, Jose F; Selva, Eduardo J; De-Barutell, Alfonso; Bouazza, Kheira

    2011-01-01

    One of the main problems posed by complete dentures is retention and stability. In order to solve this problem, dentists and the dental industry for a long time have attempted to improve denture adhesion by developing a range of "glues" of highly varied composition and efficacy. The present in vivo clinical study evaluates whether the adhesives used to improve complete denture retention are truly effective and able to increase denture adhesion to the mucosa covering the edentulous alveolar ridge.of the mandibular dentures. An in vivo clinical study is made of 30 patients with complete mandibular dentures to evaluate the retention afforded by three commercial complete denture adhesives (Benfix®, Fittydent® and Supercorega®). A spring scale was used to measure retention strength (in grams). The purpose was to determine whether the use of complete denture adhesives is effective, and to establish which commercial brands offer the highest retention strengths. The results obtained indicate that retention is enhanced by the use of such adhesives, and that Fittydent® offers the best retention performance, followed by Benfix® and Supercorega® The study of denture adhesives and his efficiency are necessary to improve the edentulous patient satisfaction. More in vivo investigations are necessary in dental literature.

  14. Functionally generated amalgam stops for single complete denture: A case report

    Directory of Open Access Journals (Sweden)

    Pravinkumar G Patil

    2009-01-01

    Full Text Available Single complete denture opposing natural dentition is a common occurrence in clinical practice. This article reports a case of a single complete denture with a technique of occlusal refinement by func-tionally generated amalgam stops condensed in prepared resin teeth after initial balancing of the den-ture with semi-adjustable articulator. This technique provides intimacy of contact in all excursions by carving the amalgam in plastic stage. Amalgam stops improve the efficiency of the resin teeth. Den-tures fabricated using this technique require fewer and simpler post-insertion adjustments.

  15. Problems with Complete Dentures and Related Factors in Patients in Rajavithi Hospital from 2007 to 2012.

    Science.gov (United States)

    Piampring, Prapin

    2016-02-01

    Complete dentures are used to restore masticatory function, improve esthetics, enhance phonetic functionality, and facilitate social communication for edentulous patients. After long-term use, problems can arise because of changes in the patients' condition and because of denture attrition. To survey problems encountered while using complete dentures, and to evaluate related factors after 3-8 years of use. One hundred and fourteen participants aged between 56 and 97 years who wore complete dentures supplied by Rajavithi Hospital between 2007 and 2012 were included in the survey. Data were collected via telephone interviews. Details were recorded for baseline characteristics of patients, how and when they used their dentures, how they maintained them, their perception of the condition of their dentures, and the problems that they encountered while using them. Descriptive statistics were used to evaluate patient characteristics and Chi-square/Fisher's exact/Student t-tests were used to evaluate correlations between condition of dentures and patient factors. A p-value of less than 0.05 was considered statistically significant. Half of all participants had problems in using complete dentures, and the most frequent difficulty was denture looseness, which affected about one-third of all patients. Marital status, whether or not participants had children, and time of wearing dentures were significantly related to having problems (p = 0.007, 0.039, and 0.003, respectively). Many complete denture patients had problems with denture looseness and dentists should recall these patients in a timely manner to help them achieve a better quality of life.

  16. Complete denture impression techniques practiced by private dental practitioners: a survey.

    Science.gov (United States)

    Kakatkar, Vinay R

    2013-09-01

    Impression making is an important step in fabricating complete dentures. A survey to know the materials used and techniques practiced while recording complete denture impressions was conducted. It is disheartening to know that 33 % practitioners still use base plate custom trays to record final impressions. 8 % still use alginate for making final impressions. An acceptable technique for recording CD impressions is suggested.

  17. Influence of defective complete dentures renewal on TMD; an MRI and clinical controlled prospective study.

    Science.gov (United States)

    Abdelnabi, Mohamed H; Swelem, Amal A

    2015-09-01

    The influence of complete denture occlusion on temporomandibular disorder (TMD) is controversial. Some studies found that defective occlusion contributes to the development of TMD, while others found no correlation. This prospective controlled study evaluated the relationship between renewal of old defective complete dentures and TMD as evidenced both by clinical examination and magnetic resonance imaging (MRI) findings. The study included 25 complete denture patients with signs and symptoms of TMD and 21 asymptomatic controls. Clicking was a common finding in all symptomatic joints. All selected participants needed complete denture renewal. MRI and clinical assessment following research diagnostic criteria for TMD guidelines (RDC/TMD) were carried out at baseline and 2 years after new complete denture insertion. Temporomandibular joint (TMJ) pain, muscle pain, clicking and movement limitation were the assessed signs and symptoms. MRIs were conducted to evaluate the TMJs for disc displacement, disc morphology and joint effusion. Complete denture renewal significantly improved the signs and symptoms of TMD in symptomatic group (p dentures did not affect disc morphology in both groups (p = 0.5 for both groups) but significantly reduced joint effusion in the symptomatic group (symptomatic p complete dentures had a positive impact on TMD signs and symptoms, disc position and joint effusion but not on disc morphology. © 2013 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  18. Evaluation of satisfaction and complications in patients with existing complete dentures.

    Science.gov (United States)

    Bilhan, Hakan; Geckili, Onur; Ergin, Selen; Erdogan, Ozge; Ates, Gokcen

    2013-03-01

    The aim of this clinical trial was to assess satisfaction, as well as the frequency and type of prosthetic complications in terms of several variables, in patients with complete dentures that had been supplied at private clinics. The study subjects were 64 patients with a mean age of 63.48 years wearing complete dentures provided at private clinics, and requesting new ones. The degree of patient satisfaction with their dentures was assessed, as well as complications and parameters related to the dentures such as the accuracy of vertical dimensions and centric relation, arrangement and possible malposition of the artificial teeth, and the border length of the denture bases. The most common complication was loss of retention (85.9%), followed by ulceration (44.2%). Mandibular dentures with long vestibular borders showed a significantly higher incidence of epulis fissuratum (P = 0.017), and denture-related sore spots influenced patients' speech ability (P = 0.023). Routine recalls seem to be important for wearers of complete dentures, as several insidious complications may develop and cause damage to the dentures as well as the patients' oral tissues.

  19. Oral health-related quality of life of edentulous patients after complete dentures relining.

    Science.gov (United States)

    Krunić, Nebojsa; Kostić, Milena; Petrović, Milica; Igić, Marko

    2015-04-01

    Tooth loss affects oral health-related life quality. More than a third of edentulous patients are not fully satisfied with their complete dentures and mainly complain of insufficient stability, retention, and pain during mastication. Solving the problem may include relining by materials that are based on silicone or acrylic. The aim of this study was to determine the level of patients' satisfaction before and after relining upper dentures with soft and rigid liners. The patients (n=24) were divided into two study groups. Maxillary denture relining of the first group of patients was performed with hard acrylic based resins while in the second group of patients complete denture was relined with a silicone-based soft liner. They were asked the questions from the specifically adapted the Oral Health Impact Profile Questionnaire for edentulous patients before and three months after relining dentures. After relining the patients showed a higher degree of satisfaction with their dentures in all the tested domains (masticatory function, psychological discomfort, social disability and retention and hygiene). The padents with soft denture relines were more satisfied. Refining of maxillary complete dentures significantly positively impacts the quality of life of patients in all the tested domains (masticatory function, psychological discomfort, social disability, pain and oral hygiene). Better results were achieved using a silicone-based soft liner, which recommends it as the material of choice for relining dentures.

  20. Oral health-related quality of life of edentulous patients after complete dentures relining

    Directory of Open Access Journals (Sweden)

    Krunić Nebojša

    2015-01-01

    Full Text Available Background/Aim. Tooth loss affects oral health-related life quality. More than a third of edentulous patients are not fully satisfied with their complete dentures and mainly complain of insufficient stability, retention, and pain during mastication. Solving the problem may include relining by materials that are based on silicone or acrylic. The aim of this study was to determine the level of patients’ satisfaction before and after relining upper dentures with soft and rigid liners. Methods. The patients (n = 24 were divided into two study groups. Maxillary denture relining of the first group of patients was performed with hard acrylic based resins while in the second group of patients complete denture was relined with a silicone-based soft liner. They were asked the questions from the specifically adapted the Oral Health Impact Profile Questionnaire for edentulous patients before and three months after relining dentures. Results. After relining the patients showed a higher degree of satisfaction with their dentures in all the tested domains (masticatory function, psychological discomfort, social disability and retention and hygiene. The patients with soft denture relines were more satisfied. Conclusion. Relining of maxillary complete dentures significantly positively impacts the quality of life of patients in all the tested domains (masticatory function, psychological discomfort, social disability, pain and oral hygiene. Better results were achieved using a silicone-based soft liner, which recommends it as the material of choice for relining dentures.

  1. SECTIONAL MANDIBULAR COMPLETE DENTURE FOR A TOTAL MAXILLECTOMY PATIENT WITH TRISMUS: A CLINICAL REPORT

    Directory of Open Access Journals (Sweden)

    Tamer ÇELAKIL

    2017-10-01

    Full Text Available This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  2. Fabrication of sectional complete denture using metal framework design for a patient with microstomia:

    Directory of Open Access Journals (Sweden)

    Rohanian A

    2010-06-01

    Full Text Available "nMicrostomia is defined as an abnormally small oral orifice. Microstomia can occur as a result of trauma from electrical and thermal lesions, chemical burns and trauma from surgeries. Prosthetic rehabilitation of microstomia patients presents difficulties at all stages, from the preliminary impressions to fabrication of prosthesis. For impression procedures different treatment methods have been suggested. Swing hinge and collapsible dentures are used to provide prosthodontic treatment to patients with microstomia. Not only is such a prosthesis difficult to fabricate, but may be expensive. The literature contains reports on the fabrication of sectional denture with the denture pieces connected by different designs. This article describes a simple method of fabricating a 2-pieces denture using removeable partial denture metal framework to connect the sections, for a patient with limited oral opening. Combination of metal framework and sectional complete denture for a patient with limited oral opening is an acceptable, effective and available method.

  3. Masticatory performance of complete denture wearers after using two adhesives: a crossover randomized clinical trial.

    Science.gov (United States)

    de Oliveira Junior, Norberto Martins; Rodriguez, Larissa Santana; Mendoza Marin, Danny Omar; Paleari, André Gustavo; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-11-01

    Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (Padhesives evaluated. The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive. Copyright © 2014

  4. Influence of vertical dimension of occlusion changes on the electroencephalograms of complete denture wearers.

    Science.gov (United States)

    Matsuda, Risa; Yoneyama, Yoshikazu; Morokuma, Masakazu; Ohkubo, Chikahiro

    2014-04-01

    The present study was conducted to identify how changes in the vertical dimension of occlusion (VDO) affect the sensory perception and activity of the brain in complete denture wearers using an electroencephalogram (EEG). Subjects were 21 individuals wearing complete dentures who regularly visited the Division of Prosthodontics at Tsurumi University Dental Hospital for checkups (12 males and 9 females, average age: 76.6). Based on their original dentures, two duplicate dentures with different VDO (-3mm and +5mm) were fabricated. EEG activity and occlusal force were measured before and after gum chewing with each denture in all subjects. Negative indicator scores for psychological conditions and stable neuronal activity (Dα) were calculated using EEG data. Statistical analysis was performed using the Wilcoxon test to compare changes in the sensory perception, activity of the brain, and occlusal force (α=0.05). After gum chewing with the +5-mm denture, a significant increase was observed in the negative indicator score (pdentures (p>0.05). A significant decrease was observed in the occlusal force between the original denture and the -3-mm denture (pcomplete denture. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  5. [Pilot evaluation of masticatory efficiency and patients' satisfaction in long-centric occlusal pattern complete denture wearers].

    Science.gov (United States)

    Liu, Xiang-hui; Liu, Jian-zhang; Xie, Qiu-fei; Kang, Yan-feng; Chen, Wei

    2013-02-18

    To assess the masticatory efficiency and patient' satisfaction in long-centric occlusal pattern complete denture wearers. The anatomic occlusal pattern and long-centric occlusal pattern complete dentures were made for each of 10 edentulous patients with severe alveolar rigde absorption simultaneously using the technique of interchangeable artificial teeth. The order of delivery of different occlusal pattern complete denture was determined according to randomized principle. For each kind of occlusal pattern complete denture, the masticatory efficiency was measured with spectrophotometer after the dentures were worn 2, 4, 6, 8, 10 and 12 weeks. A psychometric questionnaire was completed by the patients after wearing the dentures for more than three months and analyzing the patients' rating of the denture satisfaction. No significant differences in masticatory efficiency was found between the long-centric occlusal pattern complete denture wearers and the anatomic occlusal complete denture wearers. The patients' grade of denture satisfaction in long-centric occlusal pattern complete dentures wearers was significantly better than that in anatomic occlusal denture wearers (PComplete denture with long-centric occlusion can be used to improve the clinical effect of edentulous patients with severe absorption of residual alveolar rigde.

  6. A structural equation model relating oral condition, denture quality, chewing ability, satisfaction, and oral health-related quality of life in complete denture wearers.

    Science.gov (United States)

    Yamaga, Eijiro; Sato, Yusuke; Minakuchi, Shunsuke

    2013-08-01

    To investigate the relationship between mandibular ridge form, stability and retention of mandibular complete denture, accuracy of jaw relation recording, patients' perception of chewing ability, satisfaction with dentures and oral health-related quality of life (OHRQoL) in complete denture wearers. A total of 183 edentulous patients, who visited the Dental Hospital of Tokyo Medical and Dental University for new complete dentures, were recruited. Oral examination was performed. Cawood and Howell's method was used to grade the mandibular ridge form. The stability and retention of the mandibular complete denture were assessed using Kapur method. Accuracy of jaw relation recording was evaluated using a newly developed jaw relation index. Patients' perception of chewing ability was rated using a food intake questionnaire. Patients' satisfaction with complete dentures was assessed on a 100-mm visual analogue scale. OHRQoL was measured using the Japanese version of the Oral Health Impact Profile for edentulous subjects. A structural equation model was constructed based on the hypothesis that oral condition and denture quality would be related to chewing ability, satisfaction and OHRQoL. Significant relationships were found between mandibular ridge form, stability of mandibular complete denture, accuracy of jaw relation recording, perceived chewing ability, satisfaction and OHRQoL. Various fit indices were within acceptable limits. Oral condition and denture quality were related to patients' perception of chewing ability, satisfaction with dentures and OHRQoL in complete denture wearers. A favourable oral condition and denture quality are important for successful complete denture therapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Part-Digitizing System of Impression and Interocclusal Record for Complete Denture Fabrication.

    Science.gov (United States)

    Matsuda, Takashi; Goto, Takaharu; Yagi, Kazutomo; Kashiwabara, Toshiya; Ichikawa, Tetsuo

    2016-08-01

    Few studies have reported the application of digital technology to removable dentures, particularly for the process of impression and interocclusal recording for complete denture fabrication. This article describes a part-digitizing system of impression and interocclusal records for complete denture fabrication. The denture foundation area in an edentulous mouth, including the border areas and residual ridge, is outlined by tracing the surfaces with a 3-D pen-type digitizer. Specialized trays for final impressions and interocclusal records were generated using computer-aided design and manufactured using the digital data. Final impression and interocclusal records were carried out using these specialized trays. The computer-aided method using preliminary digital impressions and specialized trays would be feasible for clinical use for complete denture fabrication.

  8. The Effect of Reading Aloud Exercises for Complete Denture Patients during the Functional Rehabilitation Period.

    Science.gov (United States)

    Liu, Lang; Ye, Xiu-Hua; Li, Jie-Yin; Liao, Juan-Kun; Ye, Jian-Tao

    2017-04-01

    The focus of this study was to evaluate the effect of reading aloud on masticatory performance and patient satisfaction of patients rehabilitated with conventional complete dentures for the first time. Sixty-two edentulous patients who received conventional complete denture treatment for the first time were randomly divided into two equal groups. After insertion of the dentures, patients in group I were asked to read a news report three times per day for 4 weeks, while those in group II did not read. The reading duration increased by 5 minutes per week, from 5 minutes in the first week to 20 minutes in the fourth week. The patients' mouth opening during reading aloud was advised to gradually increase throughout the training project. Two and four weeks after insertion of the dentures, masticatory performance was assessed using the sieving method, and patient satisfaction was measured using a visual analogue scale, which combined the patient's perceptions in relation to comfort, esthetics, stability, ability to talk, and ability to chew. There were significant improvements in masticatory performance with reading aloud exercises after the insertion of complete dentures (p 0.05) at 2 weeks, but at 4 weeks, patient satisfaction regarding stability, ability to talk, and ability to chew was significantly higher for group I (p denture wearers who were treated with conventional complete dentures for the first time, and may be a useful clinical application for more effective denture treatment. © 2015 by the American College of Prosthodontists.

  9. The effect of denture design and fixatives on the retention of mandibular complete dentures tested on a novel in-vitro edentulous model.

    Science.gov (United States)

    Johnson, A; Al-Kaisy, N; Miller, C A; Martin, N

    2013-06-01

    The aim of this study was to evaluate the effect of the design (extension and adaptation) of a mandibular complete acrylic denture and the use of denture adhesives using a novel in-vitro edentulous model. The model is a highly anatomically accurate replica based on a moderately resorbed human mandibular edentulous arch. The model has been designed and fabricated by means of an elaborate clinical and technical process that employs synthetic elastomeric materials with properties that attempts to reproduce in-vitro characteristics of the soft tissues overlying the ridges and immediate reflected tissues. This model was used to measure and compare the retention of mandibular dentures ofvarying designs (well-fitting, over- and under-extended) with and without the aid of denture fixatives. Retention tests were conducted with different volumes of artificial saliva at a cross head speed of 50 mm/min with 4 equidistant holding points on the denture occlusal surface, using a universal tensile testing machine in an axial pull direction. The effect of three denture adhesives on denture retention was also tested on the same denture types at different times over a period of 5 hours and beyond. The in-vitro model presented can be effectively used to test the retention of mandibular complete dentures. The speed of dislodgement force and amount of saliva are important variables in mandibular denture retention. The retention of well-fitting dentures was statistically higher than that of ill-fitting dentures. A significantly higher retention force was needed to dislodge mandibular dentures (well and ill-fitting dentures) when using a denture adhesive.

  10. Development of complete dentures based on digital intraoral impressions-Case report.

    Science.gov (United States)

    Fang, Jing-Huan; An, Xueyin; Jeong, Seung-Mi; Choi, Byung-Ho

    2017-06-15

    A 60-year-old man presented for refabrication of his maxillary complete denture. In this case, a digital process was chosen to replace the ill-fitted complete maxillary denture. A specialized scan retractor was used to retract the mobile tissues of the lips, cheeks and vestibule while taking a digital impression. The interocclusal record obtained in the patient's mouth was scanned in order to digitally register the occlusal vertical dimension. The denture base and teeth were designed on virtual models that were mounted at the occlusal vertical dimension, and were made using CAD/CAM technology. Unlike conventional impression techniques, intraoral scanning is not able to be performed while the tissue is moving. This case report used a scan retractor that facilitated stretching and fixation of the vestibular area. It also helped to retract the lips and cheeks. This report also demonstrates that virtual models at OVD can be obtained without the use of conventional stone models, flasking or processing techniques. One of the main shortcomings in the existing CAD/CAM denture fabrication technology is that it is not able to produce customized denture teeth. The present article demonstrates that the digital denture fabrication workflow can provide customized denture teeth to optimize occlusion. This case demonstrated how digital complete dentures can be made without requiring conventional stone models or mounting the models in an articulator. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. Association between self-assessment of complete dentures and oral health-related quality of life.

    Science.gov (United States)

    Komagamine, Y; Kanazawa, M; Kaiba, Y; Sato, Y; Minakuchi, S; Sasaki, Y

    2012-11-01

    The purpose of this study was to determine which factors related to patient self-assessment of dentures are associated with changes in oral health-related quality of life (OHRQoL) among edentulous patients after replacement of complete dentures, and to determine whether masticatory performance as determined using an objective method affects the changes in OHRQoL among edentulous patients. As a preliminary study, the existing questionnaire regarding self-assessment of dentures consisting of 39 question items, measured with a 100-mm visual analogue scale, was analysed by factor analysis. Then a questionnaire, composed of 22 question items, was developed containing six subscales of 'function', 'lower denture', 'upper denture', 'expectation', 'aesthetic and speech' and 'importance'. Final participants in the present study comprised 93 edentulous patients requiring new conventional complete dentures (44 men, 49 women; mean age, 75·0 years). These patients were asked to complete the Japanese version of the Oral Health Impact Profile (OHIP)-EDENT, comprising 19 question items for assessment of OHRQoL in edentulous patients, along with the developed questionnaire regarding self-assessment of dentures. Moreover, masticatory performance was measured using a colour-changeable chewing gum. The questionnaire and measurement were completed twice; before and after replacement of complete dentures. Stepwise multiple regression analysis identified 'lower denture' and 'aesthetic and speech' as significant independent variables besides OHIP-EDENT scores before replacement. These results suggest that sufficient retention of lower dentures and appropriate appearance may lead to improved OHRQoL in edentulous patients. © 2012 Blackwell Publishing Ltd.

  12. Simplified versus traditional techniques for complete denture fabrication: a systematic review.

    Science.gov (United States)

    Paulino, Marcília R; Alves, Luana R; Gurgel, Bruno C V; Calderon, Patrícia S

    2015-01-01

    A number of methods have been described for the fabrication of complete dentures. There are 2 common ways to make conventional complete dentures: a traditional method and a simplified method. The purpose of this study was to conduct a systematic review to compare the efficiency of simplified and traditional methods for the fabrication of complete dentures. The review was conducted by 3 independent reviewers and included articles published up to December 2013. Three electronic databases were searched: MEDLINE-PubMed, The Cochrane Library, and ISI Web of Science. A manual search also was performed to identify clinical trials of simplified versus traditional fabrication of complete dentures. Six articles were classified as randomized controlled clinical trials and were included in this review. The majority of the selected articles analyzed general satisfaction, denture stability, chewing ability and function, comfort, hygiene, esthetics, speech function, quality of life, cost, and fabrication time. Although the studies reviewed demonstrate some advantages of simplified over traditional prostheses, such as lower cost and clinical time, good chewing efficiency, and a positive effect on the quality of life, the reports related the use of different simplified methods for the fabrication of complete dentures. Additional randomized controlled trials that used similar simplified techniques for the fabrication of complete dentures should be performed with larger sample sizes and longer follow-up periods. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Influence of balanced occlusion in complete dentures on the decrease in reduction of an edentulous ridge

    Directory of Open Access Journals (Sweden)

    Poštić Srđan D.

    2012-01-01

    Full Text Available Background/Aim. Balanced occlusal arrangement of artificial teeth and balanced occlusion is a specific type of occlusion that preserves the stability of complete dentures. Balanced occlusion comprises realization of tooth contacts at the working side as well as at the balancing side, at the same time. The aim of this study was to assess the influence of balanced occlusal arrangement of artificial teeth on the decrease in reduction of edentulous alveolar ridge. Methods. A longitudinal study on 91 fully edentulous patients was conducted using their panoramic radiographs and parameters of vertical dimension of edentulous ridges. All the patients were clinically examined by the same and a qualified dental practitioner. Numerical values of parameters of vertical dimensions of edentulous ridges and lines were statistically processed and compared using the Student’s t-test. Results. Vertical dimensions and heights of edentulous ridges were different after comparison of parameters in complete denture wearers with balanced occlusion and complete denture wearers without bilaterally balanced occlusion, as well as between male and female edentulous patients. Statistically significant differences of heights were established in complete denture wearers’ with a set of artificial teeth without balanced occlusion, at the baseline and 12 months after wearing of complete dentures. Conclusion. Balanced occlusion is a favored occlusal design in setting of artificial teeth in conventional complete dentures, which preserves edentulous ridge and influence the stability of dentures.

  14. Total CAD/CAM Supported Method for Manufacturing Removable Complete Dentures

    Science.gov (United States)

    Furtado de Mendonça, Mario; White, George Shelby; Sara, Georges; Littlefair, Darren

    2016-01-01

    The incorporation of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture fabrication brings about several advantages to the fabrication process, providing better predictability of the desired outcomes and high accuracy of denture fit, mainly because the milling of prepolymerized acrylic resin eliminates the shrinkage of the acrylic base. Also, there is a decrease in the porosity when compared to a conventionally processed denture, and consequently there is a decrease in the retention of Candida albicans on the denture base. The presented workflow for complete denture fabrication presents a totally wax-free manufacturing process, combining rapid prototyping (RP) and rapid milling. With the presented technique, the maxillomandibular relation (MMR) and the ideal setup of the tooth arrangement are developed by using occlusion rims and trial setup made with RP. For the definitive final denture, the denture base and the basal surfaces of the conventional denture teeth were milled according to the individual clinical situation. Posteriorly, the teeth were adapted and bonded into the milled sockets of the milled base. PMID:27974977

  15. Vinegar as an antimicrobial agent for control of Candida spp. in complete denture wearers

    Directory of Open Access Journals (Sweden)

    Telma Maria Silva Pinto

    2008-12-01

    Full Text Available The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution (pH less than 3 overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests (germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation. The results were analyzed using Spearman's correlation and Student's t-test (p£0.05. Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients.

  16. Opinions and feelings on eating with complete dentures: a qualitative inquiry.

    Science.gov (United States)

    Obrez, A; Grussing, P G

    1999-01-01

    Our knowledge of variables affecting the coping strategies that lead to acceptance of foods in populations wearing complete dentures is limited. Focus groups were conducted with the specific aim of determining factors responsible for successful adaptation to chewing with complete dentures. Each of the five focus groups consisted of eight to 15 participants (mean = 11; mean age = 64 yrs), of mixed gender, with at least five years of denture-wearing experience (mean = 7 years), and with groups varying in their socio-economic and ethnic backgrounds. Participants' statements (n = 324) were sorted for their content, by consensus between the two investigators, into 12 conceptually independent domains (listed in decreasing order of frequency of mention): foods and food textures causing difficulties when eating, foods being avoided, stability and retention of dentures, social constraints, bolus size, general satisfaction with the current dentures, general experience with dentures, sensation of temperature, experience of pain during chewing, experiences with taste, experiences with rinsing the dentures after eating, and time involved with chewing. In addition, further analysis of statements showed that food texture was the most commonly mentioned with foods that were either difficult to chew or avoided. These perceptions significantly affected the choice of food. The results of this qualitative study indicate that food texture is one of the major factors influencing the choice of a coping strategy by denture wearers when trying to overcome difficulties in chewing specific foods. As such, food texture may have a significant effect on patients' success in the process of their functional adaptation.

  17. Comparisons of patient satisfaction levels with complete dentures of different occlusions: a randomized clinical trial.

    Science.gov (United States)

    Shirani, Mohhamadjavad; Mosharraf, Ramin; Shirany, Mohammadkazem

    2014-06-01

    There is a lack of evidence to recommend a particular type of posterior occlusal form for conventional complete dentures. The type of posterior occlusal scheme can affect complete denture stability, retention, and patient satisfaction. The objective of this study was to compare patient satisfaction to three types of complete denture occlusion using a randomized, crossover controlled trial. Three sets of complete dentures were made for each of 15 patients (mean age = 58.87 ± 15.02 years). They received (1) fully bilateral balanced occlusion (BBO), (2) lingualized occlusion, and (3) buccalized occlusion (BO) denture sets in random order. After wearing each set for 6 weeks, patient satisfaction was assessed using a 19-item version of the Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT). Each question was scored on a 1 to 5 scale for patients' problems with dentures (for these ordinal variables, 1 = "never" and 5 = "very often"). These items were first analyzed by Friedman tests and then by Wilcoxon rank tests for 80% test power at the 0.05-alpha level (d = 0.7). BO resulted in lower avoidance of particular foods and physical disability scores than fully BBO. With the caution of small sample size, the results of this study provide evidence that use of BO can improve food avoidance and physical disability aspects of patient satisfaction with complete dentures. © 2013 by the American College of Prosthodontists.

  18. Patients' Evaluations of Complete Denture Therapy and Their Association with Related Variables: A Pilot Study.

    Science.gov (United States)

    Santos, Beatriz Ferreira Oliveira; dos Santos, Mateus Bertolini Fernandes; Santos, Jarbas Francisco Fernandes; Marchini, Leonardo

    2015-07-01

    Patient satisfaction is an important goal in complete denture therapy, and many factors influence this parameter. This study aimed to evaluate expectations before and satisfaction after therapy with complete dentures. As a secondary objective, other variables that may interfere with patient satisfaction were also evaluated. A representative sample of 99 patients assigned visual analog scale (VAS) scores to their expectations before and satisfaction after therapy regarding chewing, esthetics, comfort, and phonetics. Demographic data and answers to a questionnaire concerning the dentists' conduct were recorded. Multiple linear regression was used to evaluate the association among studied variables and patients' expectation and satisfaction with their dentures. The average VAS scores were high for both expectations and satisfaction, and satisfaction exceeded expectations. Patients' expectations about esthetics and comfort were associated with age and self-reported time of using complete dentures. Patient satisfaction regarding chewing was associated with the number of postdelivery adjustments. Also, patient satisfaction regarding esthetics was associated with gender and esthetic expectations. In regard to phonetic satisfaction, associations were verified among self-reported time of using complete dentures, comfort and phonetics expectations, and dentists' explanations. Comfort satisfaction was associated only with educational level. Patient satisfaction regarding complete dentures exceeded expectations and an expressive majority of positive evaluations of the dentists was noticed. Many patient-related variables seemed to influence their evaluations of their dentures. © 2015 by the American College of Prosthodontists.

  19. Maxillary Complete Denture Outcomes: A Systematic Review of Patient-Based Outcomes.

    Science.gov (United States)

    Thalji, Ghadeer; McGraw, Kate; Cooper, Lyndon F

    2016-01-01

    The aim of this systematic review is to report on the current knowledge regarding patient satisfaction as a primary outcome for maxillary complete denture therapy. We asked, "For the maxillary edentulous patient treated using maxillary dentures, what are the patient-based outcomes regarding quality of life and treatment satisfaction." An electronic search of publications up to March 2014 was established using four databases: PubMed, Web of Science, Scopus, and Embase. To meet the ultimate goal of establishing clinical guidelines based on available information, prospective comparative studies, cohort prospective studies, and retrospective studies on more than 10 subjects were included. The electronic search identified 4,530 articles that were evaluated at the title, abstract, and article level to include 31 articles of interest. The patient-based outcomes and satisfaction data included were examined and reported. The studies included 5,485 participants. Of these, 2,685 were identified as wearing maxillary complete dentures. Reported mean ages ranged from 59.7 to 73.6 years. A systematic review indicated that the provision of new maxillary complete dentures for edentulous patients results in improved self-reported satisfaction and oral health-related quality of life. The included reports, while providing evidence that complete denture satisfaction of participants and new dentures improve self-reported outcomes, did not include variables that influence these positive outcomes. A broad range of evidence supports the use of complete dentures for rehabilitation of the edentulous maxilla. When considering treatment of the edentulous maxilla, the expectations of patients for esthetic and phonetic (social) rehabilitation are high and can be met using maxillary complete dentures as the mode of prosthetic rehabilitation. Patients dissatisfied with new complete dentures may be referred for dental implant therapies involving fixed or removable prostheses.

  20. Peer Review and Quality Assessment in Complete Denture Education.

    Science.gov (United States)

    Novetsky, Marvin; Razzoog, Michael E.

    1981-01-01

    A program in peer review and quality assessment at the University of Michigan denture department is described. The program exposes students to peer review in order to assess the quality of their treatment. (Author/MLW)

  1. Xerostomia in complete denture wearers: prevalence, clinical findings and impact on oral functions.

    Science.gov (United States)

    Al-Dwairi, Ziad; Lynch, Edward

    2014-03-01

    To investigate the prevalence of dry mouth in a select sample of edentulous Jordanian older population wearing complete dentures and to evaluate its impact on oral functions. The prevalence and impact of Xerostomia as a cofactor in causing denture problems in Jordanians have not been previously investigated. This study included 455 participants (253 men and 202 women). Perception of dry mouth was measured by a pilot-tested questionnaire. Xerostomic status was confirmed clinically. Complete denture function was also assessed. One hundred and thirty six subjects (29.9%) had reported a subjective feeling of dry mouth with a prevalence of 24.9% in men (n = 63) and 36.1% in women (n = 73) (p dentures showed one or more signs suggestive of Xerostomia. The majority of xerostomic participants with different sets of complete dentures were dissatisfied with oral functions (p complete denture wearers, Xerostomia is significantly more prevalent in women and associated with increased age and smoking. Xerostomia adversely affects oral functions and overall satisfaction with dentures. © 2012 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  2. Occlusal Pressure Analysis of Complete Dentures after Microwave Disinfection: A Clinical Study.

    Science.gov (United States)

    Basso, Michael Frederico Manzolli; Giampaolo, Eunice Teresinha; Vergani, Carlos Eduardo; Pavarina, Ana Cláudia; Machado, Ana Lúcia; Jorge, Janaina Habib

    2017-10-01

    This clinical study evaluated the effect of microwave disinfection protocols on the occlusal pressure pattern of dentures. Dentures were constructed for 40 patients and evaluated as follows (n = 20). Group 1: Patients had the maxillary dentures submitted to microwave disinfection, once a week, for 4 weeks. Group 2: Patients had the maxillary dentures submitted to microwave disinfection, three times a week, for 4 weeks. Occlusal contacts were recorded on five occasions: 30 days after denture insertion and before first disinfection (baseline or control group); 1 week after disinfection; 2 weeks after disinfection; 3 weeks after disinfection; 4 weeks after disinfection. Occlusal contacts were analyzed by T-Scan III. Intergroup analysis was performed using the Mann-Whitney test and intragroup analysis using the Friedman test with significance of 5%. The results showed no significant difference between groups during the periods. The data on parameters loss of denture adaptation or complaints showed that patients used their dentures regularly for eating and expressed comfort and satisfaction in all experimental periods. The evaluation of functional occlusion revealed that the distribution of the occlusal contacts remained unaltered after disinfection. Microwave disinfection protocols as studied in this report did not influence occlusal contacts of the complete dentures. © 2015 by the American College of Prosthodontists.

  3. Three dimensional deformation of dry-stored complete denture base at room temperature

    Science.gov (United States)

    2016-01-01

    PURPOSE The aim of this study was to evaluate whether there is any typical deformation pattern existing in complete denture when it was dried by using the 3D scanner and surface matching program. MATERIALS AND METHODS A total of 28 denture bases were fabricated with heat curing acrylic resin (each 14 upper and lower denture bases), and 14 denture bases (each 7 upper and lower denture bases) were stored in the water bottle (water stored), and another 14 denture bases were stored in the air (dry stored). Each specimen was scanned at 1st day after deflasking, 14th day after deflasking, and 28th day after deflasking, and digitalized. Three dimensional deformation patterns were acquired by comparison of the data within storage group using surface matching program. For evaluating differences between groups, these data were compared statisticallyusing Kruskal Wallis and Mann Whitney-U test (α=.05). RESULTS When evaluating 3D deformation of denture base, obvious deformations were not found in maxillary and mandibular water storage group. However, in dry stored group, typical deformation pattern was detected as storage time passes. It occurred mostly in first two weeks. Major deformations were found in the bilateral posterior area in both maxillary and mandibular group. In maxillary dry stored group, a statistical significance was found. CONCLUSION It was proved that in both upper and lower denture bases, dry storage caused more dimensional deformation than water storage with typical pattern. PMID:27555899

  4. Retention of complete maxillary dentures measured as resistance against unilateral occlusal loading.

    Science.gov (United States)

    Fløystrand, F; Orstavik, J S

    1984-02-01

    Complete maxillary dentures were tested for their ability to remain in place when subjected to unilateral occlusal loads. The test material comprised five persons, each supplied with three identical dentures. The denture design was based on the principles of 1) functionally determined filling-in of the vestibular sulcus, 2) palatal coverage to the vibration line without post dam, 3) aesthetically governed positioning of the front teeth, and 4) positioning of the lateral teeth in the plane connecting the top of the residual ridge with the central part of the occlusal surface of the antagonizing natural teeth. Resistance to unilateral occlusal loads was measured by means of a miniature bite force sensor. In the pooled material, an average load of 70 N was tolerated before the dentures were dislodged. For a given participant/denture combination, the resistance against dislodgment varied considerably when tested on different days. Marked differences were also found among three identical dentures in one person. The tolerance against unilateral occlusal loads could feasibly be quantified. However, the influence of specific clinical and/or technological factors on denture retention during function should be studied only if strict definitions as to the test conditions are given. These conditions must include the time, person, and denture tested.

  5. Effects of short-term adaptation to new complete dentures on perception thresholds for interocclusal thickness in experienced and non-experienced denture wearers

    Institute of Scientific and Technical Information of China (English)

    A. Dilek Nalbant

    2004-01-01

    Background The ability of patients to discriminate thickness can change with time after the insertion of new complete dentures, and this adaptation may differ according to the experiences of the patients. If so, an education program to reinforce the oral functions may be needed. This study was to evaluate patients' ability to discriminate thickness by comparing experienced and non-experienced denture wearers after the insertion of new complete dentures. Methods Forty edentulous patients with a skeletal Class Ⅰ jaw relationship without any temporomandibular disturbances were in the study. After insertion of new complete dentures, all patients were tested for discrimination threshold for interocclusal thickness. The thickness perception test was repeated on days 1, 7, and 30 after the insertion of new dentures. The discriminatory ability was assessed with steel and aluminium foils placed between the upper and lower central incisor teeth. The records included the duration of wearing dentures. The data were subjected to statistical analysis of two-way ANOVA, multiple comparison test and Student's t test.Results Discrimination of tactile ability significantly increased over 30 days in experienced denture wearers as compared with non-experienced patients (P<0.001). The difference in thickness perception threshold was statistically significant between the two groups (P<0.001). Conclusion Adaptation and denture experience can affect thickness discrimination of complete denture wearers.

  6. Etiological factors correlated with temporomandibular disorder in complete denture wearers: a comparative analysis

    Directory of Open Access Journals (Sweden)

    Ricardo Alexandre Zavanelli

    2009-01-01

    Full Text Available Objective: The aim of this study was to make a comparative evaluation of the prevalence of temporomandibular disorder in complete denturewearers, with regard to the etiological factors, such as gender, age, and complete dentures clinical conditions, according to the anamnestic(Ai and clinical (Di dysfunction index, developed by Helkimo.Methods: The randomized sample was composed of 90 institutionalized patients and bimaxillary complete denture wearers, with a mean ageof 67.2 years, who were included in this study. The collected data were tabulated and the Kruskal-Wallis and Chi-square statistical tests were applied, at the level of significance of 5% (p<0.05.Results: Statistically significant difference in the prevalence of temporomandibular disorder was observed with regard to the ages of the current complete dentures, free-way space, wear of the occlusal surfaces of the artificial teeth, and the conditions of retention and stability of the maxillary and mandibular complete dentures, according to both the indexes. Conclusion: The patients who wore complete dentures in adequate clinical conditions presented fewer signs and symptoms of temporomandibular disorder than the patients who wore complete dentures in poor clinical conditions.

  7. Comparative study of methods for the quantification of biofilm on complete dentures

    OpenAIRE

    PARANHOS, Helena de Freitas Oliveira; Silva,Cláudia Helena Lovato da

    2004-01-01

    This study compared the application and reliability of 4 methods for biofilm quantification (computerized, paper-weighing, point-counting, and planimetric) in complete dentures, verifying the correlation between them. The internal surfaces of 62 complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the areas (total and biofilm-covered) were outlined with a pencil. These areas were measured with an equidistant point grid (point-counting metho...

  8. [Semi-adjustable articulator for computer aided design of complete denture].

    Science.gov (United States)

    Sun, Yu-Chun; L V, Pei-Jun; Wang, Yong

    2008-02-18

    To explore virtual semi-adjustable articulator for complete denture computer aided design (CAD) system, and to simulate biting motion and virtual occlusal adjustment for a complete denture CAD digital model. The edentulous jaw casts, rims and bite records of forward protrusion were made in clinic. The casts were fixed to the articulator and inclination of protrusive condylar guidance was set up with bite records of forward protrusion. Inclination of lateral condylar guidance was calculated and set up with Hanus formula. Inclination of protrusive incisal guidance inclination was calculated and set up with ratios of over bite and overjet of complete denture CAD digital model which have been designed with Complete Denture CAD System. The 3D locus data of semi-adjustable articulator was obtained by scanning three points on articulator with contact head of FARO ScanArm (FARO Technologies Inc., American). In the same scanning coordinate system, the laser scanner was used to get labial/buccal surface data of rims at centric relation position. Based on rims, the coordinate system was set up and the complete denture CAD model was aligned to the locus data. The virtual articulator program was explored with Scoll language offered by Imageware (EDS corp., American). The 3D biting motion simulating, automatic occluding relation detection and automatic occlusal adjustment functions were supported by the program. A virtual semi-adjustable articulator program for Complete Denture CAD System was explored and applied to a complete denture CAD digital model. With the program, 3D biting motion simulating, automatic occluding relation detection and automatic occlusal adjustment can be realized. A technical route of virtual articulator is set up based on semi-adjustable articulator and initial approach is carried out for application of the virtual articulator in CAD progress of complete denture.

  9. Comparative evaluation of nutritional status of elderly dentulous and completely edentulous patients wearing complete dentures

    Directory of Open Access Journals (Sweden)

    Bhumita R Makwana

    2014-12-01

    Full Text Available Introduction: The scientific progress has reached a level where nutritional interventions may play a part in the prevention of degenerative conditions of age, improvement of quality of life and impact on health care burden and resources. Moreover a timely intervention can stop weight loss in elderly at risk of malnutrition or undernourished. Evaluation of nutritional status is important for any nutrition or dietary modification. We therefore did a comparative study of evaluation of nutritional status of elderly dentulous and completely edentulous patients wearing complete dentures. Rationale: To evaluate nutritional status in dentulous and edentulous denture wearing elderly patient. To evaluate any relationship between edentulous denture wearer patient and malnutrition. To determine if the recommended dietary allowance is met by elderly dentulous and completely edentulous patients wearing complete dentures. To find out the need of nutritional supplement for edentulous complete denture wearer patients. Objectives: The objectives were to evaluate nutritional status in dentulous and edentulous denture wearing elderly patients and to find out any relationship between edentulous denture wearer patients and malnutrition. We also tried to find out the need of nutritional supplement for edentulous denture wearer patients. Material & Method: A total of 100  healthy Male and Female  patients  between the age of 60  to 80 years attending the OPD of Department of Prosthodontics, Faculty of Dental Sciences, Dharmsinh Desai University, Nadiad, Gujarat were selected and divided into two sample groups dentulous and edentulous. Subjects with no natural teeth who reported wearing complete maxillary and   mandibular dentures for at least 6 months were taken as the edentulous sample and subjects with at least 24 teeth who did not wear dentures were taken as dentulous sample. Mini Nutrition Assesment Tool, 24 Hour Diet Recall & Food Frequency Form were used to

  10. Modification of complete dentures according to the characteristics of the patient

    Directory of Open Access Journals (Sweden)

    Hasminar Hasminar

    2016-06-01

    Full Text Available Patients with total tooth loss suffered disruption to the masticatory function, appearance, and decreased quality of life. Denture can restore function and provide comfort to be used, but will reduce the aesthetic look to those who use it. Preparation of teeth for complete dentures need to be done in accordance with the needs of the patient, and not break the rules that have been obtained in dentistry. The principle of setting teeth or tooth-making will remain the same in different cases. But the impact that could lead to a dentist is making complete dentures were identics almost in all cases or patients faced. And the likelihood that this causes the patients are satisfied with the services that exist. The task of the dentist is to provide sufficient and accurate information about the complete dentures that can be changed or modified according to the patient's wishes in order to look better or nearly approaching the original tooth in general. The process of incorporation of the right gear, color and position according to the characteristics of patients can give the look more like the patients. It will have an impact on a smile and designs on someone's face. Modifications to the complete dentures will have a positive effect on the patient. Each patient has a denture that is different and unique that will be evaluated individually. In this paper, the authors give 11 reported cases of the manufacture of complete dentures which has its own characteristics. This characteristic provides unlimited possibilities to further modify the complete dentures.

  11. Prosthodontic management of worn dentition in pediatric patient with complete overlay dentures: a case report.

    Science.gov (United States)

    Kumar, Prince; Rastogi, Jyoti; Jain, Chandni; Singh, Harkanwal Preet

    2012-11-01

    Overlay complete dentures are simple, reversible and economical treatment modality for patients with congenital or acquired disorders that severely affect the tooth development. It satisfies both the esthetic and functional demands where the extraction of teeth is not generally indicated. In pediatric patients, the overlay dentures establish a relatively stable occlusion that improves patient's tolerance to the future treatment procedures for worn dentition. This clinical report highlights the imperative need of appropriate treatment strategy and application of maxillary and mandibular overlay dentures in a pediatric patient who suffered from congenitally mutilated and worn dentition.

  12. On the clinical deformation of maxillary complete dentures. Influence of the processing techniques of acrylate-based polymers.

    Science.gov (United States)

    el Ghazali, S; Glantz, P O; Randow, K

    1988-10-01

    This paper aims to study the functional deformation patterns of complete maxillary dentures constructed in three different types of denture base materials and with two techniques of processing of dentures. The patients' evaluation of the fit of the dentures was also recorded. Thirty strain-gauged duplicate dentures were made for this study of five test subjects. The functional loading tests included maximum biting and the chewing of three food test samples. The results showed that there was no correlation between the patients' evaluation and acceptance of the fit of the dentures and the actual straining magnitudes and deformation of their dentures. The results also suggest that dentures manufactured from toughened or co-polymerized poly(methyl methacrylate) and processed by the injection molding technique deform to a lesser extent than when processed by by the compression molding technique. Standard poly(methyl methacrylate) seems to be less sensitive to the processing technique.

  13. Effect of complete dentures on craniofacial growth of an ectodermal dysplasia patient: a clinical report.

    Science.gov (United States)

    Bhalla, Gaurav; Agrawal, Kaushal Kishor; Chand, Pooran; Singh, Kamleshwar; Singh, Balandra Pratap; Goel, Prachi; Alvi, Habib Ahmed

    2013-08-01

    The aim of this clinical report was to observe the effect of complete dentures on craniofacial growth and development of an ectodermal dysplasia (ED) patient. A complete anodontia patient diagnosed with ED was successfully rehabilitated with conventional complete dentures at the ages of 5, 8, and 10 years. Three sets of complete dentures were made with age-appropriate denture teeth and a bilaterally balanced lingualized occlusal scheme. Periodic follow-up and adjustment when needed was done to maintain proper oral function and esthetics. Serial cephalometric analysis exhibited a marked restriction of forward growth at the anterior nasal spine (ANS) point between 5 and 10 years of age, although there was little change from average in the anteroposterior length of the mandibular body and the height of the mandibular ramus. So, while maxillary growth was reduced, mandibular growth did not significantly change. Cast analysis showed that the increase in arch length was greater than in arch width for both the maxilla and mandible. There was little increase in alveolar ridge height in the anterior region but a considerable increase in the height of the alveolar ridge in the middle and the posterior region. Our findings concluded that the absence of teeth did not affect the growth of the jaws, and it is probable that the denture flange did not arrest the jaw growth, but rather improved the masticatory function by providing good denture stability and retention. © 2013 by the American College of Prosthodontists.

  14. Correlation between age and gender in Candida species infections of complete denture wearers: a retrospective analysis.

    Science.gov (United States)

    Loster, Jolanta E; Wieczorek, Aneta; Loster, Bartłomiej W

    2016-01-01

    Denture-related stomatitis is a disorder that often affects denture wearers. The purpose of this study was to evaluate the intensity, genera, and frequency of yeasts in the oral cavity of complete denture wearers in terms of subject gender and age. Nine hundred twenty patients (307 males and 613 females) with complete upper dentures were selected for the study and divided into four age groups: ≤50 years, 51-60, 61-70, and >70 years. Yeast samples were taken as a smear from the palate. The data were collected from January 15, 2007 to January 15, 2012. The distribution of the number of yeast colonies by gender was statistically significant (P=0.02). Across all subjects, there was a statistically significant relationship between the intensity of yeast growth and the gender (P=0.01). In every age group, the number of infection-free individuals was greater among males than females. Intermediate, intense, and abundant growth of yeast occurred most frequently in the youngest group of females. The genera of Candida species and the frequency of yeast infection in denture wearers appear to be influenced by both age and gender. The complete denture wearers ≤50 years of age appeared to have the greatest proclivity to oral Candida infections.

  15. Reliability and validity of a questionnaire for self-assessment of complete dentures.

    Science.gov (United States)

    Komagamine, Yuriko; Kanazawa, Manabu; Kaiba, Yoshinori; Sato, Yusuke; Minakuchi, Shunsuke

    2014-05-02

    Demand for complete denture treatment is expected to rise over several decades. However, to date, no questionnaire on complete dentures, as evaluated by edentulous patients, has been shown to be reliable and valid. This study sought to assess the reliability and validity of Patient's Denture Assessment (PDA), which provides a multidimensional evaluation of dentures among edentulous patients. Patients, who had new complete dentures fabricated at the University Hospital of Dentistry, Tokyo Medical and Dental University through 2009 to 2010, were enrolled. The reliability of the PDA was determined by examining internal consistency and test-retest reliability. Internal consistency for all of the question items and the six subscales was measured using Cronbach's α and average inter-item correlation coefficients among 93 participants. For 33 of these participants, test-retest reliability was determined at a 2 month-interval using the interclass correlation coefficients (ICCs) and 95% confidence interval for the summary scores and the six subscale scores. The PDA was validated in 93 participants by examining the difference in the summary score and the six subscale scores of the PDA before and after replacement with new dentures by the paired t-test. Ability to detect change was also tested in 93 patients using effect size. The Cronbach's α for the PDA ranged from 0.56 to 0.93. The average inter-item correlation coefficients ranged from 0.28 to 0.83. ICCs for the PDA ranged from 0.37 to 0.83. The paired t-test showed a significant difference between the summary score and the six subscale scores before and after replacement with new dentures (p dentures.

  16. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction

    Science.gov (United States)

    Salloum, Alaa’a M.

    2015-01-01

    Problem statement Tooth movement has been shown to occur during and after the processing of complete dentures. An understanding of this phenomenon may permit one to construct functional complete dentures that require less occlusal adjustment in the articulator and in the patient’s mouth. Purpose The purpose of this study was to examine the effects of three different investing methods on tooth movement occurring during the processing of simulated maxillary complete dentures. Material and methods Forty-five similar maxillary dentures were made using heat-polymerized acrylic resin, and assigned randomly to three experimental groups (n = 15 each) according to investing method: plaster–plaster–plaster (P–P–P), plaster–stone–stone (P-S-S), and plaster–mix (P–M). Specimens in all experimental groups were compression molded with denture base resin. Transverse interincisor (I–I) and intermolar (M–M) distances, and anteroposterior incisor–molar (LI–LM and RI–RM) distances, were measured with digital calipers at the wax denture stage (pre-polymerization) and after denture decasting (post-polymerization). Analysis of variance and Tukey’s test were used to compare the results. Results M–M, LI–LM, and RI–RM movement was significantly greater in the P–P–P group than in the P–S–S and P–M groups; no significant difference in I–I movement was observed among groups. Transverse movement along M–M and I–I was significantly greater than anteroposterior movement in the P–P–P group; no significant difference among measurements was observed in the other two groups. Conclusion The study results indicate that the use of dental stone or a 50:50 mixture of plaster and stone for investing of dentures is an important factor in efforts to control the magnitude of tooth movement. PMID:26792971

  17. Effect of a denture adhesive on the satisfaction and kinesiographic parameters of complete denture wearers: a cross-over randomized clinical trial.

    Science.gov (United States)

    Marin, Danny Omar Mendoza; Leite, Andressa Rosa Perin; Paleari, André Gustavo; Rodriguez, Larissa Santana; Oliveira Junior, Norberto Martins de; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-01-01

    The aim of the present study was to assess the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Fifty edentulous patients received a set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment protocols: Protocol 1- DA use during the first 15 days, followed by no DA for the next 15 days; Protocol 2- no DA during the first 15 days, followed by use of DA for the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to assess the patients' satisfaction. A kinesiograph was used to record mandible movements and patterns of maxillary complete denture movement during chewing. The Wilcoxon test (α=0.05) and a paired sample t-test (α=0.05) were used to compare satisfaction levels and kinesiographic data, respectively. Use of DA improved the overall level of patient satisfaction (pcomplete dentures (p=0.002) during chewing after using the DA. Use of DA in complete denture wearers improved the patients' satisfaction and altered mandible movements, with increases in vertical movements during chewing and less intrusion of maxillary complete dentures.

  18. Functional impression and jaw registration: a single session procedure for the construction of complete dentures.

    Science.gov (United States)

    Utz, K-H; Müller, F; Kettner, N; Reppert, G; Koeck, B

    2004-06-01

    The conventional fabrication of complete dentures involves two separate clinical sessions for functional impression making and jaw registration. The presented method combines both procedures in one session. The aim of this study was to survey the three-dimensional tooth positions in complete dentures with reference to the ridges to establish arbitrary guideline values that could be used for the manufacturing of tooth-position analogue plastic rims on functional impression trays. New complete dentures were fabricated by supervised undergraduate students in the conventional manner for 104 edentulous patients. The position of the maxillary teeth was surveyed in the horizontal plane using the Schmuth 'vizor-measuring plate'. The vertical dimension of occlusion, represented as the distance between opposing ridge areas of the dentures in maximum intercuspation, was measured at different sites by means of a Gutowski gauge. The tooth positions on the dentures varied widely, e.g. the horizontal distances between the incisive papilla and the maxillary incisors was 7.1 +/- 2.3 (3-14) mm. The vertical dimension of occlusion, which is most important in the jaw registration, varied equally with an anterior inter-alveolar distance between 12 and 33 (20.4 +/- 4.0) mm. Arbitrary moulding of the tooth position-analogue plastic rims does not seems to be an ideal method of pre-shaping functional impression trays, because the individual anatomical variation is considerable. Alternatively, the horizontal and vertical tooth positions of functionally and aesthetically pleasing dentures should be measured to pre-shape the rims of functional impression trays in the maxillary and the mandibular jaw. Such trays are a valuable tool for functional impressions and an immediate preliminary jaw registration in the fabrication of new complete dentures. This method allows a first try-in of the full set-up in the third clinical visit without loosing precision.

  19. Cameo surface recording in complete denture fabrication using transcutaneous electrical nerve stimulation: A clinical report.

    Science.gov (United States)

    Koli, Dheeraj; Nanda, Aditi; Kaur, Harsimran; Verma, Mahesh; Jain, Chandan

    2017-08-01

    Severe bone loss in patients with complete edentulism poses a treatment challenge. In fabricating a denture, the stability of the prosthesis must be enhanced by recording the cameo surface within the confines of the physiological position of the cheek and tongue muscles (the neutral zone) and by shaping it accordingly. The treatment of a patient with a completely edentulous maxillary arch and severe maxillary anterior bone loss is described. The cameo surface was recorded within the physiological limits during the fabrication of a complete denture by using transcutaneous electrical nerve stimulation (TENS). Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures

    Directory of Open Access Journals (Sweden)

    Katayoun Sadr

    2012-04-01

    Full Text Available Background and aims. There are many edentulous people with severely resorbed residual ridges and non-resilient lining mucosa that are unable to tolerate occlusal forces during functional and parafunctional movements. Lining the tissue surface of dentures with a flexible material can theoretically distribute and absorb forces with cushioning effect. The aim of this study was to evaluate the effect of a soft liner on stress levels in mandibular complete denture and its supporting structures by finite element analysis. Materials and methods. A simplified 3-dimensional finite element model of relatively resorbed mandible, mucosa, denture and a soft liner was prepared. Then the model, with and without soft liner, underwent normal vertical and lateral occlusal forces. The stresses were analyzed using the ANSYS 12 software. Results. Using the soft liner increased stress levels up to 18.5% and 30% in the cortical bone and mucosa, respectively, after vertical load was applied in the incisor region. Application of bilateral vertical load on the molar area increased stress in cortical bone u to 44% and in the mucosa up to 29%. Unilateral loading in the canine area increased stress level in the mucosa up to 63.5%. The highest stress was seen at denture base followed by the cortical bone. Conclusion. Use of soft liners increased stress in denture supporting structures. Higher level of stress concentration was observed primarily in the denture base followed by the cortical bone.

  1. Clinical and antimicrobial efficacy of NitrAdineTM-based disinfecting cleaning tablets in complete denture wearers

    Directory of Open Access Journals (Sweden)

    Cláudia Helena Silva-Lovato

    2010-12-01

    Full Text Available OBJECTIVE: This study evaluated the efficacy of NitrAdineTM-based disinfecting cleaning tablets for complete denture, in terms of denture biofilm removal and antimicrobial action. MATERIAL AND METHODS: Forty complete denture wearers (14 men and 26 women with a mean age of 62.3±9.0 years were randomly assigned to two groups and were instructed to clean their dentures according to two methods: brushing (control - 3 times a day with denture brush and tap water following meals; brushing and immersion (Experimental - brushing the denture 3 times a day with denture brush and tap water following meals and immersion of the denture in NitrAdineTM-based denture tablets (Medical InterporousTM. Each method was used for 21 days. Denture biofilm was disclosed by a 1% neutral red solution and quantified by means of digital photos taken from the internal surface before and after the use of the product. Microbiological assessment was conducted to quantify Candida sp. RESULTS: An independent t-test revealed a significant lower biofilm percentage for the experimental group (4.7, 95% CI 2.4 to 7.9 in comparison with the control group (mean 37.5, 95% CI 28.2 to 48.1 (t38=7.996, p<0.001. A significant reduction of yeast colony forming units could be found after treatment with Medical InterporousTM denture tablets as compared to the control group (Mann-Whitney test, Z=1.90; p<0.05. CONCLUSION: The present findings suggest that NitrAdineTM-based disinfecting cleaning tablets are efficient in removal of denture biofilm. In addition, a clear antimicrobial action was demonstrated. Therefore, they should be recommended as a routine denture maintenance method for the prevention of the development of microbial biofilm induced denture stomatitis.

  2. Study protocol for a multi-center, randomized controlled trial to develop Japanese denture adhesive guidelines for patients with complete dentures: the Denture Adhesive Guideline trial: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Kimoto, Suguru; Kawai, Yasuhiko; Gunji, Atsuko; Kondo, Hisatomo; Nomura, Taro; Murakami, Tomohiko; Tsuboi, Akito; Hong, Guang; Minakuchi, Shunsuke; Sato, Yusuke; Ohwada, Gaku; Suzuki, Tetsuya; Kimoto, Katsuhiko; Hoshi, Noriyuki; Saita, Makiko; Yoneyama, Yoshikazu; Sato, Yohei; Morokuma, Masakazu; Okazaki, Joji; Maeda, Takeshi; Nakai, Kenichiro; Ichikawa, Tetsuo; Nagao, Kan; Fujimoto, Keiko; Murata, Hiroshi; Kurogi, Tadafumi; Yoshida, Kazuhiro; Nishimura, Masahiro; Nishi, Yasuhiro; Murakami, Mamoru; Hosoi, Toshio; Hamada, Taizo

    2016-10-18

    Denture adhesives, characterized as medical products in 1935 by the American Dental Association, have been considered useful adjuncts for improving denture retention and stability. However, many dentists in Japan are hesitant to acknowledge denture adhesives in daily practice because of the stereotype that dentures should be inherently stable, without the aid of adhesives. The aim of this study is to verify the efficacy of denture adhesives to establish guidelines for Japanese users. The null hypothesis is that the application of denture adhesives, including the cream and powder types, or a control (isotonic sodium chloride solution) would not produce different outcomes nor would they differentially improve the set outcomes between baseline and day 4 post-application. This ten-center, randomized controlled trial with parallel groups is ongoing. Three hundred edentulous patients with complete dentures will be allocated to three groups (cream-type adhesive, powder-type adhesive, and control groups). The participants will wear their dentures with the denture adhesive for 4 days, including during eight meals (three breakfasts, two lunches, and three dinners). The baseline measurements and final measurements for the denture adhesives will be performed on the first day and after breakfast on the fourth day. The primary outcome is a general satisfaction rating for the denture. The secondary outcomes are denture satisfaction ratings for various denture functions, occlusal bite force, resistance to dislodgement, masticatory performance, perceived chewing ability, and oral health-related quality of life. Between-subjects comparisons among the three groups and within-subjects comparisons of the pre- and post-intervention measurements will be performed. Furthermore, a multiple regression analysis will be performed. The main analyses will be based on the intention-to-treat principle. A sample size of 100 subjects per group, including an assumed dropout rate of 10 %, will be

  3. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives.

    Science.gov (United States)

    Bidra, Avinash S; Taylor, Thomas D; Agar, John R

    2013-06-01

    Computer-aided technology is an emerging method for fabricating complete dentures. Consolidated information about historical background, current status, and scope for the future is lacking. The purpose of this systematic review was to analyze the existing literature on computer-aided technology for fabricating complete dentures and provide the reader with a historical background, current status, and future perspectives on this emerging technology. An electronic search of the English language literature between the periods of January 1957 and June 2012 was performed by using PubMed/MEDLINE with the following specific search terms: CAD-CAM complete dentures, digital complete dentures, computer dentures, designed dentures, machined dentures, manufactured dentures, milled dentures, and rapid prototyping dentures. Additionally, the search terms were used on the Google search engine to identify current commercial manufacturers and their protocols. A total of 1584 English language titles were obtained from the electronic database, and the systematic application of exclusion criteria resulted in the identification of 8 articles pertaining to computer-aided technology for complete dentures. Since the first published report in 1994, multiple authors have described different theoretical models and protocols for fabricating complete dentures with computer-aided technology. Although no clinical trials or clinical reports were identified in the scientific literature, the Google search engine identified 2 commercial manufacturers in the United States currently fabricating complete dentures with computer-aided design and computer-aided manufacturing (CAD/CAM) technology for clinicians world-wide. These manufacturers have definitive protocols in place and offer exclusive dental materials, techniques, and laboratory support. Their protocols contrast with conventional paradigms for fabricating complete dentures and allow the fabrication of complete dentures in 2 clinical appointments

  4. Effects of offset values for artificial teeth positions in CAD/CAM complete denture.

    Science.gov (United States)

    Yamamoto, Shinta; Kanazawa, Manabu; Iwaki, Maiko; Jokanovic, Ana; Minakuchi, Shunsuke

    2014-09-01

    Recently, computer-aided design/computer-aided manufacturing (CAD/CAM) technology has been applied to the field of removable complete denture prosthodontics. We developed a system for fabricating complete dentures applying CAD/CAM technology. In this system, artificial teeth were bonded to the recesses of a milled denture base. However, the offset values needed for the recesses are not known. The purpose of the present study was to evaluate the accuracy of bonded artificial teeth positions in 0.00 (control), 0.10, 0.15, 0.20, and 0.25mm offset recess groups. Four types of artificial teeth, upper left central incisor (UL1), upper left canine (UL3), upper left first premolar (UL4), and upper left first molar (UL6), were used. Each type of artificial tooth was arranged at regular intervals on the denture base model with the CAD software. These data were defined as the master data. The artificial teeth parts were subtracted from the denture base model by Boolean logic operations in order to make recesses, and the recesses were then offset in five values. Based on these denture base data, prepolymerized resin blocks were milled (n=3). After bonding artificial teeth on the milled denture base model, a cone beam computed tomography (CBCT) scan was performed to obtain scanned data. Deviations between the master data and the scanned data were calculated. Based on the results, the optimal offset values were found to be 0.15-0.25mm for UL1, 0.15 and 0.25mm for UL3, 0.25mm for UL4, and 0.10-0.25mm for UL6.

  5. Effects of complete denture wearing on the head posture and posterior airway space: A cephalometric study†

    Directory of Open Access Journals (Sweden)

    Hasan Suat Gokce

    2011-03-01

    Conclusion: Airway protection maintenance with extension and flexion of the head is vital because any rehabilitation involves the head and neck region. Correlation coefficients indicated significant changes in dynamic measurements of the natural head position related to complete dentures. Immediate head extension and alterations of posterior airway dimensions were observed following airway obstruction because of the insertion of complete dentures. The significant changes found in the study should help practitioners understand the mechanisms of craniofacial and cranio-vertical features before planning massive rehabilitations that reduce the oral cavity space.

  6. Clinical strategies for complete denture rehabilitation in a patient with Parkinson disease and reduced neuromuscular control.

    Science.gov (United States)

    Haralur, Satheesh B

    2015-01-01

    The dentist has a large role in geriatric health care for the ever increasing elder population with associated physical and neurological disorders. The Parkinson disease is progressive neurological disorder with resting tremor, bradykinesia, akinesia, and postural instability. The psychological components of disease include depression, anxiety, and cognitive deficiency. Poor oral hygiene, increased susceptibility for dental caries, and periodontal diseases predispose them to early edentulism. The number of Parkinson affected patients visiting dental clinic seeking complete denture is growing. This case report explains the steps involved in the complete denture rehabilitation of Parkinson patient. The effective prosthesis will help in alleviating functional, aesthetic, and psychological disabilities of the patient.

  7. Clinical Strategies for Complete Denture Rehabilitation in a Patient with Parkinson Disease and Reduced Neuromuscular Control

    Directory of Open Access Journals (Sweden)

    Satheesh B. Haralur

    2015-01-01

    Full Text Available The dentist has a large role in geriatric health care for the ever increasing elder population with associated physical and neurological disorders. The Parkinson disease is progressive neurological disorder with resting tremor, bradykinesia, akinesia, and postural instability. The psychological components of disease include depression, anxiety, and cognitive deficiency. Poor oral hygiene, increased susceptibility for dental caries, and periodontal diseases predispose them to early edentulism. The number of Parkinson affected patients visiting dental clinic seeking complete denture is growing. This case report explains the steps involved in the complete denture rehabilitation of Parkinson patient. The effective prosthesis will help in alleviating functional, aesthetic, and psychological disabilities of the patient.

  8. Complete denture base assessments using holograms: dimensional alterations after different activation methods

    Science.gov (United States)

    Dughir, Ciprian; Popovschi, Ana Maria; Cojocariu, Andreea Codruta; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Sinescu, Cosmin; de Sabata, Aldo; Duma, Virgil-Florin

    2016-03-01

    Holography is a well-developed method with a large range of applications, including dentistry. This study uses holographic methods for the study of total dental prosthesis. The issue is that the transformation of wax denture base in polymethylacrylate causes dimensional alterations and retractions in the final dental constructs. These could cause the failure of the stability of the complete denture in the oral cavity. Thus, the aim of this study is to determine and to compare using holography, total prosthesis obtained using three different manufacturing methods: pressing, injection, and polymerization. Each of the three types of dentures thus produced were recorded over the previously wax complete base holographic plates. The dimensional alterations that appear after using the different activation methods were thus determined. The most significant modification was remarked in the custom press technology, while the smallest variations were detected in the injection alternative.

  9. Contour of lingual surface in lower complete denture formed by polished surface impression

    Science.gov (United States)

    2016-01-01

    PURPOSE The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for use when manufacturing edentulous trays and lower complete dentures. MATERIALS AND METHODS Twenty-six patients with mandibular edentulism were studied. After lower wax dentures were fabricated, wax was removed from the lingual side of the wax denture and a lingual polished surface impression was obtained with tissue conditioner. The definitive denture was scanned with a three-dimensional scanner, and scanned images were obtained. At the cross-sections of the lingual frenum, lateral incisors, first premolars, first molars, and anterior border of the retromolar pads, three points were marked and eight measurements were taken. The Kruskal-Wallis test and a post hoc analysis with the Mann-Whitney test were performed. RESULTS Each patient showed similar values for the same areas on the left and right sides without a statistically significant difference. The height of the contour of the lingual polished surface at the lingual frenum was halfway between the occlusal plane and lingual border, it moved gradually in a downward direction. The angle from the occlusal plane to the height of the contour of the lingual polished surface was increased as it progressed from the lingual frenum towards the retromolar pads. CONCLUSION The shape of the mandibular lingual polished surface was convex at the lingual frenum, lateral incisors and gradually flattened towards the first molars and retromolar pads. PMID:28018565

  10. Frenectomy for improvement of a problematic conventional maxillary complete denture in an elderly patient: a case report.

    Science.gov (United States)

    Al Jabbari, Youssef S

    2011-12-01

    Maxillary labial and buccal frena are considered as normal anatomic structures in the oral cavity. However, they may exist intraorally as a thick broad fibrous attachment and/or become located near the crest of the residual ridge, thus interfering with proper denture border extension resulting in inferior denture stability, retention and overall patient satisfaction. This case report highlights the importance of clinical examination and treatment planning which may mandate preprosthetic surgery prior to fabrication of a new conventional complete denture. Adequate patient satisfaction with conventional complete dentures can be significantly increased after frenectomy.

  11. Occlusal designs on masticatory ability and patient satisfaction with complete denture: a systematic review.

    Science.gov (United States)

    Zhao, Ke; Mai, Qing-Qing; Wang, Xiao-Dong; Yang, Wen; Zhao, Li

    2013-11-01

    To systematically review clinical outcomes of different occlusal designs of complete dentures. Using a various key words, an electronic search of clinical trials published in English and Chinese literature was performed from four databases: Medline/PubMed, EMBASE, Cochrane Library, and CBM. Furthermore, a manual searching of the relevant journals and the bibliographies of reviews was performed. General satisfaction, masticatory ability, retention, and stability were major criteria for the evaluation of the outcomes. Studies met these criteria were selected for a full-text reading. The whole processes were performed by two reviewers independently. This systematic review started with 1030 articles, which were finally narrowed down to seven, according to the inclusion criteria. The following occlusal designs were included and analyzed: anatomic occlusion, balanced occlusion, canine guidance occlusion, lingualized occlusion, monoplane occlusion, and bilateral-balanced and canine-guided design. Three of the seven studies showed that lingualized occlusion had ratings of higher patients' satisfaction than other occlusion designs. On the other hand, the canine-guided occlusion dentures demonstrated equal or better clinical performances than bilateral-balanced dentures. Because of the heterogeneity and bias of the studies, it was not possible to analyze the data statistically. Lingualized occlusion and canine-guided occlusion can be successfully applied in the fabrication of complete dentures. Canine guided occlusion has also been shown to be satisfactory. More well-controlled randomized trials are needed regarding canine-guided occlusion and the relationship between alveolar ridge resorption, different occlusal schemes and patient satisfaction. The conventional prosthodontic wisdom that complete dentures require a balanced occlusal design is not supported by the included literature. A suitable occlusal scheme would be a critical factor for a successful complete denture

  12. Correlation of masticatory muscle activity with masticatory ability in complete denture patients with canine guidance and balanced occlusion

    Science.gov (United States)

    Maxwell, D.; Odang, R. W.; Koesmaningati, H.

    2017-08-01

    Balanced occlusion is commonly used in complete denture occlusion scheme; however, canine guidance offers a simpler process and reduces alveolar ridge resorption. Correlative research of these two occlusion schemes is required. This study was done to analyze the correlation between masticatory muscle activity and masticatory ability of the subjects with canine guidance and balanced occlusion complete dentures. Ten denture wearers participated in this cross-over clinical trial, and five subjects were randomly selected to wear balanced occlusion followed by canine guidance complete dentures and vice versa. Electromyogram (EMG) activities of superficial masseter and anterior temporal muscles were measured and masticatory ability questionnaires were collected 30 days after the subjects wore each occlusal scheme. There were significant differences between the EMG activities of masticatory muscles in subjects who were given canine guidance and balanced occlusion complete dentures (p dentures (p = 0.046). There was a significant and strong correlation (p = 0.045; r = 0.642) between the EMG activity of anterior temporal muscles and masticatory ability when the subjects wore balanced occlusion dentures and between the EMG activity of superficial masseter muscles and masticatory ability (p = 0.043; r = 0.648) when wearing canine guidance dentures. Masticatory ability is better when using canine guidance dentures. There is a significant and strong correlation between masticatory muscle activity and masticatory ability.

  13. The use of existing denture-satisfaction ratings for a diagnostic test to indicate prognosis with newly delivered complete dentures.

    Science.gov (United States)

    Kawai, Yasuhiko; Matsumaru, Yuichi; Kanno, Kyoko; Kawase, Mitsuaki; Kawase, Mitsuo; Shu, Kazuyoshi; Izawa, Takeshi; Gunji, Atsuko; Kobayashi, Kihei

    2009-10-01

    The study investigated the relation between subjective satisfaction ratings of existing dentures and outcomes of newly delivered dentures, and the ability of the diagnostic test, using existing ratings, to indicate prognosis with newly delivered dentures. Consecutive 165 edentulous patients were recruited from November 2001 to August 2006 at a university-affiliated hospital. Dentures were fabricated with an acrylic base with full-balanced occlusion using hard resin artificial teeth by multiple prosthodontists. At the baseline and 3-month after delivery, patients rate their overall, maxillary, and mandibular satisfaction for existing and replaced dentures on a 100-mm visual analogue scale (VAS). The association between baseline ratings and newly delivered dentures was analyzed by regression analysis. The test's performance was measured by constructing a two-by-two table; patients with the following cutoff values on the VAS (overall: dentures. Relative validity of the diagnostic tests was assessed by means of sensitivity, specificity, and likelihood ratios. Mandibular dentures showed a significant association between baseline and new dentures (coefficient=0.27, p=0.01). Results of test measures for overall, maxillary, and mandibular existing dentures were 71%, 38%, and 87% (sensitivity); 62%, 66%, and 49% (specificity); and 1.1, 1.9, and 1.7 (positive likelihood), and 0.5, 1.0, and 0.2 (negative likelihood). Test performance indicates that the negative (satisfied) result for mandibular existing dentures may be useful to rule out the unsatisfied patients with new mandibular dentures.

  14. Fabrication of complete dentures in three visits using existing prosthesis-a simplified technique for geriatric patients.

    Science.gov (United States)

    Kulkarni, Rahul S; Pawar, Ravindra S

    2017-03-01

    Complete edentulism often limits patients' ability to masticate and perform other oral functions, resulting in a reduction of oral-health-related quality of life. Although the two-implant mandibular overdenture may be considered as a minimum standard of treatment of complete edentulism, patients often prefer conventional complete dentures due to cost and surgical procedures related to implant supported dentures. Many complete denture patients may have limited access to dental care due to socioeconomic or health issues, hence there is a need in simplification of complete denture fabrication. Researchers have proposed "simplified" techniques to fabricate complete dentures by eliminating two stage impression procedures facebow transfer, and articulator programming, with impressive initial results. However, long-term clinical data of these techniques is unavailable. A novel technique for fabricating simplified complete dentures in three visits, using patient's existing dentures is presented here. Unlike previously described techniques on "simplified" dentures, this technique does not eliminate vital steps such as border-molded impressions, facebow transfer, verification of centric relations during try-in, programming of the articulator, and balancing procedures. © 2016 Special Care Dentistry Association and Wiley Periodicals, Inc.

  15. Survival of microorganisms on complete dentures following ultrasonic cleaning combined with immersion in peroxide-based cleanser solution.

    Science.gov (United States)

    Nishi, Yasuhiro; Seto, Katsura; Kamashita, Yuji; Kaji, Akihito; Kurono, Asutsugu; Nagaoka, Eiichi

    2014-09-01

    To compare ultrasonic cleaning combined with immersion in a commercially available peroxide-based cleanser solution (Polident(®) ) with other denture cleaning methods, we examined the quantity of micro-organisms that survived on dentures before and after various cleaning methods. One hundred complete dentures belonging to 50 nursing home residents (mean age, 84.6 years) were randomly assigned to five groups according to the cleaning method employed: (A) immersion in Polident(®) solution alone, (B) brushing with water, (C) ultrasonic cleaning with water, (D) method (A) followed by method (B) and (E) ultrasonic cleaning combined with immersion in Polident(®) solution. Before and after the dentures had been cleaned, denture biofilm was collected from the mucosal surface of each lateral half of the examined dentures. The collected micro-organisms were cultured, presumptively identified by standard methods and quantified. Comparisons between the five cleaning methods were carried out using the Kruskal-Wallis test and Dunn's multiple comparisons test. The denture cleaning methods involving the use of Polident(®) solution (methods A, D and E) were significantly more effective at denture disinfection than the other methods (p dentures and is a suitable method for elderly individuals who find brushing their dentures difficult. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  16. CAD/CAM complete dentures: a review of two commercial fabrication systems.

    Science.gov (United States)

    Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z

    2013-06-01

    The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.

  17. Modification of complete dentures according to the characteristics of the patient

    OpenAIRE

    Hasminar Hasminar; Ike Damayanti Habar

    2016-01-01

    Patients with total tooth loss suffered disruption to the masticatory function, appearance, and decreased quality of life. Denture can restore function and provide comfort to be used, but will reduce the aesthetic look to those who use it. Preparation of teeth for complete dentures need to be done in accordance with the needs of the patient, and not break the rules that have been obtained in dentistry. The principle of setting teeth or tooth-making will remain the same in different cases. But...

  18. Two-center clinical trial of implant-retained mandibular overdentures versus complete dentures - Chewing ability

    NARCIS (Netherlands)

    Geertman, ME; Boerrigter, EM; VantHof, MA; VanWaas, MAJ; vanOort, RP; Boering, G; Kalk, W

    This study is a two-center clinical trial with the aim to assess the treatment effects of implant-retained mandibular overdentures versus conventional complete dentures. Treatment had been assigned according to a balanced allocation method. The following criteria were used to enhance the

  19. Clinical and antimicrobial efficacy of NitrAdineTM-based disinfecting cleaning tablets in complete denture wearers

    Science.gov (United States)

    SILVA-LOVATO, Cláudia Helena; DE WEVER, Bart; ADRIAENS, Els; PARANHOS, Helena de Freitas Oliveira; WATANABE, Evandro; PISANI, Maria Xavier; de SOUZA, Rafael Freitas; ITO, Isabel Yoko

    2010-01-01

    Objective This study evaluated the efficacy of NitrAdineTM-based disinfecting cleaning tablets for complete denture, in terms of denture biofilm removal and antimicrobial action. Material and methods Forty complete denture wearers (14 men and 26 women) with a mean age of 62.3±9.0 years were randomly assigned to two groups and were instructed to clean their dentures according to two methods: brushing (control) - 3 times a day with denture brush and tap water following meals; brushing and immersion (experimental) - brushing the denture 3 times a day with denture brush and tap water following meals and immersion of the denture in NitrAdineTM-based denture tablets (Medical InterporousTM). Each method was used for 21 days. Denture biofilm was disclosed by a 1% neutral red solution and quantified by means of digital photos taken from the internal surface before and after the use of the product. Microbiological assessment was conducted to quantify Candida sp. Results An independent t-test revealed a significant lower biofilm percentage for the experimental group (4.7, 95% CI 2.4 to 7.9) in comparison with the control group (mean 37.5, 95% CI 28.2 to 48.1) (t38=7.996, pdenture tablets as compared to the control group (Mann-Whitney test, Z=1.90; pdenture biofilm. In addition, a clear antimicrobial action was demonstrated. Therefore, they should be recommended as a routine denture maintenance method for the prevention of the development of microbial biofilm-induced denture stomatitis. PMID:21308285

  20. Effect of dentist's clinical experience on treatment satisfaction of a complete denture.

    Science.gov (United States)

    Kimoto, S; Kimoto, K; Kitamura, A; Saita, M; Iijima, M; Kawai, Y

    2013-12-01

    The relationship between the prosthodontic experience of dentists and satisfaction of complete denture wearers remains unknown. To investigate whether a prosthodontist's clinical experience affects treatment satisfaction of a complete denture wearer. From April 2004 to July 2006, we conducted a randomised controlled trial at two centres, including 74 edentulous patients; of these, 32 and 30 were randomly allocated to the ED or ID group, respectively. All the patients rated their satisfaction with dentures, including general satisfaction and satisfaction of chewing ability, speaking, cleaning, stability, retention, comfort and aesthetics. These satisfaction ratings were measured by a 100-mm visual analog scale (VAS). Perceived chewing ability to foods, divided into five grades, was measured using a questionnaire. The mastication index (MI) was calculated for each grade. General satisfaction and satisfaction of speaking, stability and retention were significantly higher in the ED than in the ID group (P = 0·049, 0·003, 0·019 and 0·041, respectively). No significant difference existed between the MI of the ED (71·3 ± 18·4) and ID group (64·1 ± 16·53). However, the perceived chewing ability of grade 5 food, whose texture was the hardest among all the grades, was significantly higher in the ED group than in the ID group. Within its limitations, this study showed that a clinician's prosthodontic experience affects a complete denture wearer's satisfaction ratings.

  1. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability.

  2. Changes in Oral Health Related Quality of Life (OHRQoL) 
and Satisfaction with Conventional Complete Dentures Among Elderly People.

    Science.gov (United States)

    Erić, Jelena; Tihaček Šojić, Ljiljana; Bjelović, Ljiljana; Tsakos, Georgios

    To assess the changes in oral health-related quality of life (OHRQoL) and satisfaction among older adults after receiving new complete dentures, and the association of age, gender, education, medical history, past prosthetic history (number of previous complete dentures and time since current complete dentures) and quality of existing complete dentures with patients' ratings of satisfaction with their complete dentures. The study comprised 114 community-dwelling adults ≥ 65 year of age, all wearing complete dentures in both jaws. The sample was selected from four senior day centres. Data were collected using clinical oral examinations and a self-administered questionnaire. Dentures were clinically evaluated for retention, stability, occlusion, articulation and vertical dimension. The questionnaire recorded data on sociodemographic information, previous denture history, oral satisfaction scale (OSS), and OHRQoL through the Oral Impacts on Daily Performance (OIDP) scale. There was a significant improvement in OHRQoL after treatment (mean OIDP score: 2.7) compared to before treatment (mean OIDP score: 6.6). The largest changes were in relation to impacts on eating (33.3% to 15.9%) and smiling (17.5% to 4.5%). Six months after placement of the dentures, patient satisfaction improved compared to before treatment (p complete dentures. The provision of new dentures among older adults resulted in significantly better satisfaction and OHRQoL than wearing existing dentures. There was no significant correlation between the clinical assessment of the dentures and patients' satisfaction with them.

  3. [Mechanical analysis of the denture bases using the photoelastic-coating method. 2. Upper complete denture bases under uniform bending moment load].

    Science.gov (United States)

    Takayama, Y; Takakuda, K; Miyairi, H

    1989-11-01

    Deformation of the anterior teeth and palatal regions on upper complete dentures was investigated using the photoelastic coating method and strain gages. In this experiment, an uniform-moment bending load method was employed to simulate the occlusal situation, and the distribution of strain in epoxy resin, stainless swaged and Co-Cr alloy cast dentures were measured and analyzed. The 030-series reflection polariscope is compact and lightweight with its main components consisting of two polarizer/quarter-wave-plate assemblies attached to a common frame. The highest level of strain was seen in the anterior region of the palate and the low strain was observed in other regions. Differences in strain magnitude of the three dentures were not observed with test at the same point. But, when denture base materials with high flexural rigidity and bending strength were used on the palatal region of the denture base, strain was decreased in the anterior and other regions of the palate. Therefore, dentures using those materials could be effectively reinforced.

  4. Nitric Oxide Concentration and Other Salivary Changes after Insertion of New Complete Dentures in Edentulous Subjects

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Breseghelo

    2016-01-01

    Full Text Available Objective. To assess changes in levels of salivary nitric oxide (NO after insertion of new complete dentures and its association with clinical and salivary parameters. Methods. Nineteen fully edentulous subjects were included, mean age 64.4. Unstimulated whole saliva was collected before and after insertion of the dentures, at follow-up visits, and after 12 months. The concentration of the final stable NO product (nitrite was measured by a colorimetric assay based on the Griess reaction. Clinical parameters were assessed during all clinical visits. Results. Functional adaptation to the dentures progressively improved, with no complaints at the long-term follow-up. NO concentration was not influenced by the level of functional adaptation, presence of injuries to the mucosa, salivary flow, and saliva viscosity. Pairwise comparison showed a reduction in NO concentration at the first follow-up compared to baseline values but differences were not statistically significant. Significant differences were observed in NO concentrations at the long-term follow-up when compared to the first (p=0.024 and second (p=0.027 visits. Conclusion. NO concentration reduced after denture insertion and returned to baseline levels in the long-term follow-up. This appears to be an autonomic response of the body and provides valuable complementary information for the management of the edentulous patient.

  5. The importance of a two-step impression procedure for complete denture fabrication: a systematic review of the literature.

    Science.gov (United States)

    Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M

    2016-10-01

    The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.

  6. Treating the modern complete denture patient: a review of the literature.

    Science.gov (United States)

    Ivanhoe, John R; Cibirka, Roman M; Parr, Gregory R

    2002-12-01

    This article reviews the physical and mental compromises of today's patients, techniques, materials, occlusion, impressions, and soft liners and makes recommendations as to managing these compromises when fabricating complete dentures. References used were primarily from the "classical literature," and an effort was made to ascertain whether these treatment recommendations are appropriate for today's more difficult patients. An effort was made to incorporate recent recommendations where appropriate.

  7. Finite element analysis of the stress-concentrating effect of fraenal notches in complete dentures.

    Science.gov (United States)

    Rees, J S; Huggett, R; Harrison, A

    1990-01-01

    Based on clinical experience and empiricism, it was postulated that fraenal notches and midline diastemas lead to fracture of complete dentures. This study used finite element stress analysis to investigate the stress-concentrating effect of a fraenal notch with and without a midline diastema. It was found that a large fraenal notch resulted in high stress levels and that these stresses were augmented more by a narrow median diastema than its wider counterpart.

  8. Power spectrum density analysis for the influence of complete denture on the brain function of edentulous patients - pilot study

    Science.gov (United States)

    Perumal, Praveen; Anitha, Kuttae Viswanathan; Reddy, Jetti Ramesh; Muthukumar, Balasubramanium

    2016-01-01

    PURPOSE This pilot study was to find the influence of complete denture on the brain activity and cognitive function of edentulous patients measured through Electroencephalogram (EEG) signals. MATERIALS AND METHODS The study recruited 20 patients aged from 50 to 60 years requiring complete dentures with inclusion and exclusion criteria. The brain function and cognitive function were analyzed with a mental state questionnaire and a 15-minute analysis of power spectral density of EEG alpha waves. The analysis included edentulous phase and post denture insertion adaptive phase, each done before and after chewing. The results obtained were statistically evaluated. RESULTS Power Spectral Density (PSD) values increased from edentulous phase to post denture insertion adaption phase. The data were grouped as edentulous phase before chewing (EEG p1-0.0064), edentulous phase after chewing (EEG p2-0.0073), post denture insertion adaptive phase before chewing (EEG p3-0.0077), and post denture insertion adaptive phase after chewing (EEG p4-0.0096). The acquired values were statistically analyzed using paired t-test, which showed statistically significant results (P<.05). CONCLUSION This pilot study showed functional improvement in brain function of edentulous patients with complete dentures rehabilitation. PMID:27350852

  9. Comparative study of maxillary complete dentures constructed of metal base and metal structure framework.

    Science.gov (United States)

    Ohkubo, C; Kurtz, K S; Suzuki, Y; Hanatani, S; Abe, M; Hosoi, T

    2001-02-01

    A removable denture designed using a three-dimensional cast metal framework (hereafter referred to as the 'structurally designed' denture) could extend denture longevity because it is unbreakable and easy to adjust. The aim of the present clinical study was to compare two types of maxillary removable dentures: conventional dentures and structurally designed denture. One edentulous and five partially dentate patients were fitted with two maxillary dentures made from the same impression and same occlusal relationship. About 20 days after delivery of the denture, masticatory analysis was conducted chewing phase (open, closed, and occluded); coefficients of variation and average variation were calculated. Denture vibration during tapping was then measured using an accelerometer. The patients were also interviewed about comfort, ease of chewing, speech, stability, aesthetics and preference for regular use. For both masticatory movements and denture vibration, there were no significant differences (P>0.1) between the conventional denture and the structural design denture. In evaluating the dentures according to each criteria, the significant superiority of one denture over the other could not be determined. However, all patients subjectively preferred the structurally designed dentures for regular use. According to these findings, structurally designed dentures do not appear to have any particular physiological problems as compared with the conventional dentures.

  10. A clinical study to evaluate and compare the masticatory performance in complete denture wearers with and without soft liners.

    Science.gov (United States)

    Tata, Sreeharsha; Nandeeshwar, D B

    2012-11-01

    Soft liners are mainly used with complete dentures in case of poor mucosal conditions and for the even distribution of masticatory forces. However, there is some doubt as to whether the elasticity of the soft liner disturbs masticatory function because denture wearers may need extra force to compress the soft liners, leading to muscle fatigue. So, this clinical study was done to evaluate and compare the masticatory performance in patients wearing complete dentures with and without the use of soft liners. Twenty edentulous subjects were selected for the study. For each patient two sets of complete dentures were fabricated. First set without the use of soft liner and the second one for using with soft liner. Peanuts were selected as test food for the study and the chewed food was pooled for a single measurement and then poured on sieves. Both filter and filtrate were collected and was centrifuged. Masticatory performance in this study has been quantitated by dividing the volume of test food passing through the sieve by the total volume of test food recovered. The fraction is then expressed as a percent. With the paired t-test performed, significant difference was found between the masticatory performance in patients wearing complete dentures with and without the use of soft liners. 5% difference was seen in the mean performance. It has been concluded from this study that, masticatory performance in patients wearing complete dentures with the use of soft liners was improved by 5% when compared to the patients wearing complete dentures without using soft liners. This present study indicates that the masticatory performance enhanced with the use of soft liners for complete denture patients.

  11. Frequency of Temporomandibular Disorders in Asymptomatic Removable Partial and Complete Denture Wearers

    Directory of Open Access Journals (Sweden)

    N. Dulčić

    2006-01-01

    Full Text Available A dogmatic view on occlusion as the main aetiological factor for temporomandibular disorder (TMD has been present in the literature for a long time, but a direct scientific correlation between occlusal disorders and TMD has never been proven. The purpose of this study was to determine the frequency of TMD signs and tissue-specific diagnoses in a population of 164 asymptomatic participants, 70 removable partial denture wearers and 94 complete denture wearers of an average age of 61.3 years, by means of clinical manual functional analysis. TMD was found in 42.1% of the participants. No statistically significant difference in the occurrence of TMD was found between removable partial and complete denture wearers and between genders (P > 0.05. The most frequent tissue-specific diagnoses were osteoarthrosis (11%, total anterior disc displacement (9.1% and partial anterolateral disc displacement (8.5%. The frequency of tissue-specific diagnoses was also not influenced by the type of prosthetic replacements.

  12. Stress analysis of a complete maxillary denture under various drop impact conditions: a 3D finite element study.

    Science.gov (United States)

    Sunbuloglu, Emin

    2015-01-01

    Complete maxillary dentures are one of the most economic and easy ways of treatment for edentulous patients and are still widely used. However, their survival rate is slightly above three years. It is presumed that the failure reasons are not only due to normal fatigue but also emerge from damage based on unavoidable improper usage. Failure types other than long-term fatigue, such as over-deforming, also influence the effective life span of dentures. A hypothesis is presumed, stating that the premature/unexpected failures may be initiated by impact on dentures, which can be related to dropping them on the ground or other effects such as biting crispy food. Thus, the behavior of a complete maxillary denture under impact loading due to drop on a rigid surface was investigated using the finite element method utilizing explicit time integration and a rate-sensitive elastoplastic material model of polymethylmethacrylate (PMMA). Local permanent deformations have been observed along with an emphasis on frenulum region of the denture, regardless of the point of impact. Contact stresses at the tooth-denture base were also investigated. The spread of energy within the structure via wave propagation is seen to play a critical role in this fact. Stress-wave propagation is also seen to be an important factor that decreases the denture's fatigue life.

  13. Problems Faced by Complete Denture-Wearing Elderly People Living in Jammu District

    Science.gov (United States)

    Sharma, Sumeet; Singh, Sarbjeet; Wazir, Nikhil; Raina, Rajiv

    2014-01-01

    Context: Poor oral health is increasing dramatically among old people especially those living in rural and remote areas. Various factors such as low education background, low income, poor living conditions, unhealthy lifestyle, inadequate oral hygiene and tobacco use lead to poor oral health among older people which in turn lead to risks to their general health. The older people especially from rural areas are apprehensive about seeing a dentist and do not visit them regularly. This may lead to various problems which may have a detrimental influence on their quality of life. Aim: To know the problems faced by complete denture wearers in rural areas in Jammu district. Materials and Methods: Fifty patients from rural area Bishna, initially treated with a complete denture in the maxilla or mandibles were examined. The data were collected with the help of a questionnaire. Results: The results revealed that majority of respondents were in the age – group of 65-70 y. Majority of respondents complained of "difficulty chewing", "sore spots”, “painful and swollen gums". Majority of respondents had difficulty in speech, it was difficult for them to interact and communicate with their dentures on. Most of the respondents had lost confidence and had low self esteem. Clinical observations revealed that the commonest condition associated with denture wearing was Oral Stomatitis/ Burning mouth Syndrome, Superimposed infection and Angular cheilitis. Conclusion: Older people should Communicate and visit dentists, regularly, so that the dentists can adjust the treatment and pace according to their needs. Behavioural therapy techniques can make dental visits relatively anxiety and pain-free. PMID:25654025

  14. Preliminary functional impression for the mandibular complete denture.

    Science.gov (United States)

    Aiche, H

    1989-01-01

    A technique for producing a preliminary impression of a resorbed edentulous mandibular ridge is presented. A 2-mm metal wire is adapted to the curve of the mandibular arch. A high-viscosity impression material is then formed to the wire and placed in the patient's mouth. Speech movements are used to functionally shape the material. Following polymerization, additional material is added to create extensions not captured in the first impression. A final wash using a low-viscosity silicone or polysulfide rubber material completes the impression. The resultant preliminary impression has the advantage of not being distorted by an ill-fitting stock tray or artificially manipulated by the clinician.

  15. Comparative evaluation of effect of complete denture wears on the flow rate of saliva in both medicated and apparently healthy patients

    Science.gov (United States)

    Sonthalia, Abhay; Chandrasekaran, Arun P.; Mhaske, Sheetal P.; Lau, Mayank; Joshy, V. R.; Attokaran, George

    2016-01-01

    Aim and Objectives: In the denture wearing people, saliva is necessary to create adhesion, cohesion, and surface tension that ultimately leads to the increased retention of the denture. Medications have some influence on the flow rate of saliva and denture retention. The present study evaluates the effect of complete denture wear on the flow rate of saliva in both medicated and apparently healthy patients. Materials and Methods: The participants were 42 edentulous individuals aged 35–70 years requiring complete denture prostheses. The participants were divided into two groups of medicated and unmedicated. Unstimulated whole saliva was collected at 24 h and 3 months after the insertion of new complete dentures in both the groups. The data obtained were analyzed using Student's paired t-test and unpaired t-test. Intergroup changes were compared with unpaired t-test. Intragroup changes were compared with paired t-test using the Statistical Package for Social Sciences, version 22.0. Results: In the unmedicated group, the mean salivary flow rate was high at 24 h after denture insertion when compared to before denture insertion (P = 0.001 VHS). In the medicated group, the observation was highly significant (P = 0.007 HS) 24 h after denture insertion and after 3 months (P = 0.02 S) when compared to before denture insertion. Conclusion: No significant difference in the salivary flow rate was found 3 months after denture insertion when compared to before denture insertion for both the medicated and unmedicated groups. PMID:27382537

  16. Effect of Patient’s Personality on Satisfaction with Their Present Complete Denture and after Increasing the Occlusal Vertical Dimension: A Study of Edentulous Egyptian Patients

    Directory of Open Access Journals (Sweden)

    Shaimaa M. Fouda

    2014-01-01

    Full Text Available Complete denture wearers often find it difficult to accept a new denture. Personality traits are among the factors that possibly affect patient satisfaction with a complete denture. Our aim was to investigate the influence of patients’ personality on satisfaction with their present denture and after an increase in the occlusal vertical dimension (OVD. Sixty edentulous patients with complete dentures (22 men and 38 women, mean age 66 years, and range 50–75 years participated in the study. The age of their complete dentures ranged from 5 to 16 years. Patients’ personalities were evaluated using the Arabic version of the Eysenck Personality Questionnaire. Their satisfaction with their dentures before and after restoration of the OVD and relining of the mandibular denture was evaluated using two questionnaires (I and II, Patients with a high score of neuroticism were less satisfied with their original dentures and after relining and an increase of OVD compared with patients with an average score in that trait. The personality trait of psychoticism was significant to patients’ acceptance of an increase in OVD; that is, patients with a high score were less satisfied with their dentures after increase of OVD than patients with an average score. It is concluded that personality traits affect patients’ acceptance of their complete dentures.

  17. Effect of Patient's Personality on Satisfaction with Their Present Complete Denture and after Increasing the Occlusal Vertical Dimension: A Study of Edentulous Egyptian Patients.

    Science.gov (United States)

    Fouda, Shaimaa M; Al-Attar, Mohamed S; Virtanen, Jorma I; Raustia, Aune

    2014-01-01

    Complete denture wearers often find it difficult to accept a new denture. Personality traits are among the factors that possibly affect patient satisfaction with a complete denture. Our aim was to investigate the influence of patients' personality on satisfaction with their present denture and after an increase in the occlusal vertical dimension (OVD). Sixty edentulous patients with complete dentures (22 men and 38 women, mean age 66 years, and range 50-75 years) participated in the study. The age of their complete dentures ranged from 5 to 16 years. Patients' personalities were evaluated using the Arabic version of the Eysenck Personality Questionnaire. Their satisfaction with their dentures before and after restoration of the OVD and relining of the mandibular denture was evaluated using two questionnaires (I and II), Patients with a high score of neuroticism were less satisfied with their original dentures and after relining and an increase of OVD compared with patients with an average score in that trait. The personality trait of psychoticism was significant to patients' acceptance of an increase in OVD; that is, patients with a high score were less satisfied with their dentures after increase of OVD than patients with an average score. It is concluded that personality traits affect patients' acceptance of their complete dentures.

  18. Complete French Teach Yourself

    CERN Document Server

    Graham, Gaelle

    2010-01-01

    The best-selling complete course for a fun and effective way to learn French. This ISBN is for the paperback book. The corresponding audio support (ISBN: 9781444100068) is also available. The book and audio support can also be purchased as a pack (ISBN: 9781444100051).

  19. Duplication of complete dentures using general-purpose handheld optical scanner and 3-dimensional printer: Introduction and clinical considerations.

    Science.gov (United States)

    Kurahashi, Kosuke; Matsuda, Takashi; Goto, Takaharu; Ishida, Yuichi; Ito, Teruaki; Ichikawa, Tetsuo

    2017-01-01

    To introduce a new clinical procedure for fabricating duplicates of complete dentures by bite pressure impression using digital technology, and to discuss its clinical significance. The denture is placed on a rotary table and the 3-dimensional form of the denture is digitized using a general-purpose handheld optical scanner. The duplicate denture is made of polylactic acid by a 3-dimensional printer using the 3-dimensional data. This procedure has the advantages of wasting less material, employing less human power, decreasing treatment time at the chair side, lowering the rates of contamination, and being readily fabricated at the time of the treatment visit. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. Stress area of the mandibular alveolar mucosa under complete denture with linear occlusion at lateral excursion

    Institute of Scientific and Technical Information of China (English)

    LU Ya-lin; LOU Hang-di; RONG Qi-guo; DONG Jian; XU Jun

    2010-01-01

    Background The rocking and instability of a loaded complete denture (CD) during lateral excursion reduce the bearing area under the denture base, causing localized high stress concentrations. This can lead to mucosal tenderness, ulceration, and alveolar bone resorption, and the linear occlusion design was to decrease the lateral force exerted on the denture and to ensure denture stability. But it is not known how the bearing areas of linear occlusal CDs (LOCDs) and anatomic occlusal CDs (AOCDs) differ. The purpose of this study was to analyze and compare the distributions of the high and low vertical stress-bearing areas in the mandibular alveolar mucosa under LOCDs and AOCDs at lateral excursion.Methods Computerized tomography (CT) and finite element analysis were used to establish three-dimensional models of an edentulous maxilla and mandible with severe residual ridge resorption. These models were composed of maxillary and mandibular bone structure, mucosa, and the LOCD or AOCD. Lateral excursion movements of the mandible were simulated and the vertical stress-bearing areas in the mucosa under both mandibular CDs were analyzed using ANSYS 7.0.Results On the working side, the high stress-bearing (-0.07 to -0.1 Mpa) area under the LOCD during lateral excursion was smaller than that under the AOCD, while the medium stress-bearing (-0.03 to -0.07 Mpa) area under the LOCD was 1.33-fold that under the AOCD. The medium stress-bearing area on the non-working side under the LOCD was 2.4-fold that under the AOCD. Therefore, the overall medium vertical stress-bearing area under the LOCD was 20% larger than that under the AOCD.Conclusions During lateral excursion, the medium vertical stress-bearing area under a mandibular LOCD was larger and the high vertical stress-bearing area was smaller than that under an AOCD. Thus, the vertical stress under the LOCD was distributed more evenly and over a wider area than that under the AOCD, thereby improving denture stability.

  1. The role of polymerization cycle and post-pressing time on tooth movement in complete dentures

    Directory of Open Access Journals (Sweden)

    Wagner Araujo de Negreiros

    2009-12-01

    Full Text Available This study analyzed the influence of polymerization cycle and post-pressing time on tooth movement in complete dentures. Forty maxillary complete dentures were fabricated and randomly assigned to 8 groups (n = 5; the polymerization cycle (conventional long cycle in water bath, fast cycle in boiling water, and by microwave energy and the post-pressing time (immediate and 6 hours were varied. Metal reference pins were placed on the incisal border of the central incisors (RI and LI, on the buccal cusp of the first premolars (RP and LP, and on the mesiobuccal cusp of the second molars (RM and LM. Two transverse and 2 anteroposterior distances were measured with a linear optical microscope (Olympus Optical Co., Tokyo, Japan with an accuracy of .0005 mm, before and after processing the complete dentures. The data collected were submitted to analysis of variance (ANOVA and the Tukey Test at a significance level of 5%. When Clássico, a conventional heat-polymerizable acrylic resin, was polymerized by microwave energy, tooth movement was statistically significant for 2 distances, with the highest value being observed for the 6-hour post-pressing time. Onda-Cryl microwave acrylic resin processed by microwave energy presented the lowest tooth movement for 2 distances, considering the 6-hour post-pressing time. QC-20 acrylic resin presented no statistically significant change considering both post-pressing times in each distance evaluated. Tooth movement showed an asymmetric behavior, so the mastering of the processing method is essential to the precise execution of all laboratory steps, irrespective of the polymerization cycle and post-pressing time used.

  2. Geriatric slim implants for complete denture wearers: clinical aspects and perspectives

    Science.gov (United States)

    Huard, Cedric; Bessadet, Marion; Nicolas, Emmanuel; Veyrune, Jean-Luc

    2013-01-01

    Background Advances made in prevention have helped postpone complete edentulism in older patients. However, in the elderly, the physiological state reduces patients’ ability to adapt to oral rehabilitation and degrades the patient’s oral condition. Consequently, elderly edentulous subjects avoid many types of foods, which can lead to substantial nutritional consequences. Complete dentures retained by implants are, currently, the treatment of reference in prosthodontic mandibular rehabilitation. Indeed, the mandibular symphysis generally tolerates implantation, even when the mandible is strongly resorbed. However, in the elderly, implant rehabilitation is compromised by the complexity of the surgical protocol and possible postoperative complications. In this context, the use of geriatric “slim implants” (GSI) offers an interesting alternative. Methods In the present study, the surgical and prosthetic procedures for the use of GSI in a French dental hospital are presented. The objective was the stabilization of a complete mandibular denture in an elderly person, with the immediate implantation of four GSI. Results The operating procedure was found to be less invasive, less expensive, simpler, and more efficient than the conventional procedure. Conclusion The result strongly suggests that this protocol could be used systematically to treat complete edentulism in very elderly patients. Long-term monitoring and the evaluation of the reliability of this type of rehabilitation should be undertaken. PMID:24009432

  3. Effect of an acrylic resin-based resilient liner applied to mandibular complete dentures on satisfaction ratings among edentulous patients.

    Science.gov (United States)

    Kimoto, Suguru; Kimoto, Katsuhiko; Murakami, Hiroshi; Atsuko, Gunji; Ogawa, Akina; Kawai, Yasuhkio

    2014-01-01

    The aim of this study was to investigate whether an acrylic resin-based resilient liner (ARL) could improve the satisfaction ratings of complete denture wearers. The null hypothesis was that no difference exists between the satisfaction ratings of conventional acrylic resin denture (CARD) wearers and those of ARL denture (ARLD) wearers. From April 2004 to July 2006, a randomized controlled trial was conducted at two centers, including 74 edentulous patients. Of these, 37 patients were each randomly allocated to the ARLD and CARD groups. All of the patients rated their satisfaction with dentures, including general satisfaction and satisfaction with chewing ability, speaking, cleaning, stability, retention, comfort, and esthetics. These satisfaction ratings were measured by a 100-mm visual analog scale. Perceived chewing ability of different foods, divided into five grades, was measured using a questionnaire. The mastication index (MI) was calculated for each grade. General satisfaction, satisfaction with chewing, and satisfaction with speaking were significantly higher in the ARLD than in the CARD group (P = .049, .025, and .049, respectively). The chewing satisfaction with maxillary dentures in the ARLD group was significantly higher than that of the CARD group (P = .02). No significant difference existed between the MI of the ARLD (69.2 ± 17.0) and CARD groups (66.7 ± 18.7). Within its limitations, this study showed that the ARL improves a complete denture wearer's satisfaction ratings.

  4. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study

    Science.gov (United States)

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    Aim: The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Materials and Methods: Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results: Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Conclusion: Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction. PMID:27041898

  5. Stabilization of mandibular complete dentures by four mini implants: Impact on masticatory function.

    Science.gov (United States)

    Batisse, C; Bonnet, G; Bessadet, M; Veyrune, J L; Hennequin, M; Peyron, M A; Nicolas, E

    2016-07-01

    The frequent instability of mandibular removable complete dentures causes an alteration of mastication. An innovative therapeutic strategy involves placing four symphyseal mini implants. This study aimed at assessing the development of masticatory parameters and the impact on quality of life in subjects that underwent this procedure. Eleven edentulous subjects (mean age 72±11 years) with unstable mandibular complete dentures were followed-up before (T0) and two - three months after (T1) mini implant setting. Physiological parameters (number of cycles, duration of sequence and frequency of mastication) during the mastication of food models and the bolus median particle size (d50) of carrot were evaluated at each time. Quality of life was assessed at T0 and T1 using the Global Oral Health Assessment Index (GOHAI). Parametric tests were used to test relationships between mastication, quality of life variations and mini implant setting, and to compare each parameter mean value at times T0 and T1. More subjects were able to chew carrot after setting the mini implants (8 subjects compared to 4 at T0). This improvement was accompanied by changes in kinematic parameters when chewing carrots, soft and hard model food, and by an improvement of their quality of life. However, the particle size values observed in the bolus remained higher than for normal dentate subjects (9.2±2.8mm). These results indicated that the placement of mini implants as retentive elements for mandibular full dentures had a positive impact on patients' masticatory function and quality of life. The placement of mini implants has a positive impact on the masticatory function and oral health quality of life. The results suggest that this alternative procedure can be used as a treatment option for patients unable to receive conventional implants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Influence of guidance concept in complete dentures on oral health related quality of life - Canine guidance vs. bilateral balanced occlusion.

    Science.gov (United States)

    Schierz, Oliver; Reissmann, Daniel

    2016-10-01

    To compare the impact of canine guided vs. bilateral balanced occlusion on oral health related quality of life (OHRQoL) as a patient-reported outcome measure. In this randomized single-blind crossover trial, 19 patients have been provided with new complete dentures in the maxilla and mandible. OHRQoL was assessed using the 49-item Oral Health Impact Profile (OHIP-49) before the start of the prosthodontic treatment (B), 3 months after insertion of the new dentures (T1), and 3 months after rework into the alternative concept (T2). Multilevel mixed-effect linear regression models were computed to determine the effect provided by the new set of dentures and the specific impact of the occlusal concept on OHRQoL using summary scores of the OHIP-49 and of a 19-items subset specific for edentulous patients (OHIP-EDENT). At baseline, participants' OHRQoL was substantially impaired indicated by an average OHIP-49 score of 42.1 points and an OHIP-EDENT score of 21.1 points. The effect of provision of a new set of complete dentures was a statistically significant decrease of 8.3 points (OHIP-49) and 4.0 points (OHIP-EDENT), respectively, representing a clinically relevant improvement in OHRQoL. When wearing dentures with bilateral balanced occlusion, participants showed on average 1.6 points higher OHIP-49 scores and 0.9 points higher OHIP-EDENT scores compared to canine guided dentures. This effect of the occlusal concept was neither statistically nor clinically significant. Both investigated occlusal concepts for complete dentures were comparable in their effect on patients' perceptions with none being considerably superior in terms of OHRQoL. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  7. A New System for Choosing the Form and Size of Complete Denture Anterior Teeth

    Directory of Open Access Journals (Sweden)

    Dario Melilli

    2016-01-01

    Full Text Available Introduction: In the absence of pre-extraction records, the choice of the size an form of anterior complete denture teeth can be extremely subjective. Several clinical and statistical parameters are usually used for choosing the correct size and form of the complete denture anterior teeth. Clinical Innovation: The technique consists of a system that allows the dentist to choose and, if necessary, easily change the dental mold during maxillomandibular recording session. The unique feature of the system is that six teeth of each mold are represented by veneers, which are connected to each other on the lingual surface by a fiber that allows each veneer some degree of movement. Discussion: This technique allows the three-dimensional verification of the patient’s esthetics and realistic phonetic test during the session of maxillomandibular records; if necessary, the dentist may easily replace the mold with a different one in form or size, without working the wax to move or replace a tooth.

  8. The influence of maxillary central incisor position in complete dentures on /s/ sound production.

    Science.gov (United States)

    Runte, C; Lawerino, M; Dirksen, D; Bollmann, F; Lamprecht-Dinnesen, A; Seifert, E

    2001-05-01

    The insertion of prosthodontic restorations often leads to speech defects, most of which are transient but nevertheless a source of concern to the patient. For the dental practitioner, there are few guidelines on designing a prosthetic restoration with maximum phonetic success. This study investigated the effect of different maxillary central incisor positions on phonetic patterns. The inclination angle of central incisor blocks in duplicate complete maxillary dentures was changed in a range of -30 degrees to +30 degrees from the original position (0 degrees). Test words and sentences were acoustically analyzed. Spectral parameters such as first peak, noise band (defined by upper and lower limits of the most intensively blackened frequency area), Fast Fourier Transformation power spectrum, energy spectrum, and time were investigated. Influences of oral stereognosis, hearing, and age as cofactors on /s/ articulation were also taken into account. The change of incisor block angle in both directions usually caused a poorer execution of the /s/ sound. The labial angulation seemed to have a greater effect than the palatal angulation. The most significant changes were those in the noise band and energy spectrum. Immediate phonetic adaptation of prosthetic restorations in the maxillary incisor region can be achieved only if the original position of the natural teeth is transferred to the denture. Although these misarticulations are, in most cases, likely to disappear within a few weeks, they may persist and even lead to psychosocial problems. A better understanding of the causes of misarticulation and the limits of adaptation according to certain morphologic parameters of dentures is important.

  9. Influence of high expansion dental stone on the changes in the occlusal vertical dimension of complete dentures.

    Science.gov (United States)

    Salloum, A M

    2013-12-01

    Although many factors that generate changes in OVD of complete dentures are known, no information is available in the dental literature regarding the effect of using high expansion dental stone (type V) on changes in OVD. This study therefore investigated the effect of a high expansion dental stone on the changes in OVD of complete dentures. A compression moulding technique was used to process twenty sets of simulated upper and lower dentures. Sample was equally divided into two groups: group of type III dental stone (DST III), and group of type V dental stone (DST V). In DST III, the lower, middle and upper parts of flask were filled with type III dental stone; In DST V, the procedure was the same as DST III except for the middle layer that was made of type V high expansion dental stone. Changes in OVD were measured before and after denture processing. A Shapiro-Wilk Normality Test was applied, and then collected data were analysed with t-test statistics for statistically significant differences at the 95% confidence level. The two groups revealed small but statistically significant increase in OVD as a result of processing. The increase in OVD was significantly less in DST V than in DST III. The use of high expansion dental stone can be recommended as investing material to reduce the increase in OVD that occurs after processing complete dentures.

  10. Effect of Occlusal Scheme on the Pressure Distribution of Complete Denture Supporting Tissues: An In Vitro Study

    Science.gov (United States)

    Madalli, Poornima; Murali, C R; Subhas, Sambit; Garg, Surbhi; Shahi, Prinka; Parasher, Pragati

    2015-01-01

    Background: The complete denture teeth arrangement that gives maximum denture stability, comfort, esthetics, and function have been studied since several years. Many occlusal schemes have been advised in which the lingualized occlusion, balanced occlusion, and monoplane occlusion are advocated most popularly. The purpose of this study was to compare the pressure values on the supporting tissue using three diff erent posterior occlusal schemes: Balanced occlusion, lingualized occlusion, and monoplane occlusion in simulated dentures Materials and Methods: The simulators used in this study, composed of the maxillary, and mandibular clear heat cure acrylic resin edentulous models. Pressures on the supporting structure under the complete denture were measured using eight strain gauges placed on the model surface on the buccal and lingual slopes of the ridges on the molar and pre-molar region. Pressure on the supporting structure was measured and signals from the sensors were amplifi ed and recorded by the multi-channel electronic strain indicator. Results: The mean pressure which was obtained at each measurement point was compared by one-way ANOVA test. Conclusion: Overall monoplane occlusion had lesser pressure values compared to completely balanced and lingualized occlusal scheme. Lingualized occlusal scheme was found to transfer stresses from working side to non-working side to stabilize the mandibular denture. PMID:26668486

  11. Influence of one- or two-stage methods for polymerizing complete dentures on adaptation and teeth movements

    Directory of Open Access Journals (Sweden)

    Moises NOGUEIRA

    Full Text Available Abstract Introduction The quality of complete dentures might be influenced by the method of confection. Objective To evaluate the influence of two different methods of processing muco-supported complete dentures on their adaptation and teeth movements. Material and method Denture confection was assigned in two groups (n=10 for upper and lower arches according to polymerization method: 1 conventional one-stage - a wax trial base was made, teeth were arranged and polymerized; 2 two-stage method - the base was waxed and first polymerized. With the denture base polymerized, the teeth were arranged and then, performed the final polymerization. Teeth movements were evaluated in the distances between incisive (I-I, pre-molars (P-P, molars (M-M, left incisor to left molar (LI-LM and right incisor to right molar (RI-RM. For the adaptation analysis, dentures were cut in three different positions: (A distal face of canines, (B mesial face of the first molars, and (C distal face of second molars. Result Denture bases have shown a significant better adaptation when polymerized in the one-stage procedure for both the upper (p=0.000 and the lower (p=0.000 arches, with region A presenting significant better adaptation than region C. In the upper arch, significant reduction in the distance between I-I was observed in the one-stage technique, while the two-stage technique promoted significant reduction in the RI-RM distance. In the lower arch, one-stage technique promoted significant reduction in the distance for RI-RM and two-stage promoted significant reduction in the LI-LM distance. Conclusion Conventional one-stage method presented the better results for denture adaptation. Both fabrication methods presented some alteration in teeth movements.

  12. Influence of different flasking and polymerizing methods on the occlusal vertical dimension of complete dentures.

    Science.gov (United States)

    Silva-Concílio, Lais R; Meloto, Carolina B; Neves, Ana Christina C; Cunha, Leonardo G; Rizzatti-Barbosa, Célia M

    2012-01-01

    The flasking and polymerization technique for resins can introduce stresses during processing which may lead to denture base distortions, artificial teeth displacement and increases in the occlusal vertical dimension (OVD). This study investigated whether the association of microwave heat-activation (MH) and bimaxillary flasking (BF) minimizes the possible increases in OVD after prostheses processing. Forty pairs of complete dentures were waxed with the artificial teeth in closed occlusion and divided into four groups according to investing and heating methods: G1 (control) = monomaxillary/water bath; G2 = monomaxillary/microwave; G3 = bimaxillary/water bath and G4 = bimaxillary/microwave. OVD was measured using a digital caliper before and after prostheses processing. Results were submitted to statistical analysis (Student's t-test for multiple comparisons and post hoc ANOVA, alpha = 0.05). Comparison of values before and after processing showed that OVD increased in all groups after polymerization (p < 0.001), regardless of flasking and polymerization methods. Statistically, G2 had the greatest difference in OVD when compared to G1 (p = 0.014), G3 (p = 0.019) and G4 (p = 0.024). G3 and G4 showed similar results statistically when compared to G1 (control). Both investing and heating methods resulted in an increase in OVD after processing. However, the prostheses invested in bimaxillary flasks showed the lowest changes in OVD, regardless of the polymerization method.

  13. Application of sintered titanium alloys to metal denture bases: a study of titanium powder sheets for complete denture base.

    Science.gov (United States)

    Doi, H; Harrori, M; Hasegawa, K; Yoshinari, M; Kawada, E; Oda, Y

    2001-02-01

    The purpose of this study was the fabrication of titanium powder sheets to enable the application of sintered titanium alloys as metal denture bases. The effects of titanium particle shape and size, binder content, and plasticizer content on the surface smoothness, tensile strength and elongation of titanium powder sheets was investigated. To select a suitable ratio of powdered metal contents for application as a metal denture base, the effects of aluminum content in Ti sheets and various other powder metal contents in Ti-Al sheets on the density, sintering shrinkage, and bending strength were evaluated. Based on the results of the above experiments, we developed a mixed powder sheet composed of 83Ti-7Al-10Cr with TA45 titanium powder (atomized, -45 microm), and 8 mass% binder content. This titanium alloy sheet had good formability and ductility. Its sintered titanium alloy had a density of 3.2 g/cm3, sintering shrinkage of 3.8%, and bending strength of 403 MPa. The titanium alloy sheet is clinically acceptable for fabricating denture bases.

  14. MASTICATION, PHONETICS AND ESTHETICS AS A FINAL RESULT OF PARTIAL OR COMPLETE DENTURE TREATMENT.

    Directory of Open Access Journals (Sweden)

    Kalina Georgieva

    2015-08-01

    Full Text Available Three target groups- dentists/ dental students, dental technicians and patients were asked to fill in an anonymous questionnaire about their satisfaction of the final results after prosthetic treatment with removable dentures using a scale from 1 to 5 (1- completely dissatisfied, 2-dissatisfied, 3-indifferent, 4-satisfied, 5-completely satisfied. The mean results (including colour, shape and size of artificial teeth, arrangement of front teeth, colour of artificial gums, phonetics, mastication, natural smile, enough space for tongue for all three groups of respondents were compared. Dental technicians (4,34 are more satisfied than dentists/dental students (3,62 and patients (3,53. A successful outcome of prosthetic treatment depends on one hand on the professional approach of the dental team and on the other hand on the patient’s motivation and cooperation. The predictive final results and realistic expectations lead to satisfaction of all participants in the treatment process.

  15. Geriatric slim implants for complete denture wearers: clinical aspects and perspectives

    Directory of Open Access Journals (Sweden)

    Huard C

    2013-08-01

    Full Text Available Cedric Huard,2 Marion Bessadet,1,2 Emmanuel Nicolas,1,2 Jean-Luc Veyrune,1,21Clermont Université, Université d'Auvergne, Centre de Recherche en Odontologie Clinique, Clermont-Ferrand, France; 2CHU Clermont-Ferrand, Service d'Odontologie, Clermont-Ferrand, FranceBackground: Advances made in prevention have helped postpone complete edentulism in older patients. However, in the elderly, the physiological state reduces patients' ability to adapt to oral rehabilitation and degrades the patient's oral condition. Consequently, elderly edentulous subjects avoid many types of foods, which can lead to substantial nutritional consequences. Complete dentures retained by implants are, currently, the treatment of reference in prosthodontic mandibular rehabilitation. Indeed, the mandibular symphysis generally tolerates implantation, even when the mandible is strongly resorbed. However, in the elderly, implant rehabilitation is compromised by the complexity of the surgical protocol and possible postoperative complications. In this context, the use of geriatric "slim implants" (GSI offers an interesting alternative.Methods: In the present study, the surgical and prosthetic procedures for the use of GSI in a French dental hospital are presented. The objective was the stabilization of a complete mandibular denture in an elderly person, with the immediate implantation of four GSI.Results: The operating procedure was found to be less invasive, less expensive, simpler, and more efficient than the conventional procedure.Conclusion: The result strongly suggests that this protocol could be used systematically to treat complete edentulism in very elderly patients. Long-term monitoring and the evaluation of the reliability of this type of rehabilitation should be undertaken.Keywords: gerodontology, oral health, prostheses, mini-implant

  16. The impact of complete denture making instructional videos on self-directed learning of clinical skills.

    Science.gov (United States)

    Kon, Haruka; Botelho, Michael George; Bridges, Susan; Leung, Katherine Chiu Man

    2015-04-01

    The aim of this research was to evaluate the effectiveness of a clinical instructional video with a structured worksheet for independent self-study in a complete denture program. 47 multilingual dental students completed a task by watching an instructional video with subtitles regarding clinical complete denture procedures. After completion, students evaluated their learning experience, and 11 students participated in focus group interviews to gain further insight. A mixed-methods approach to data collection and analysis provided descriptive statistical results and a grounded theory approach to coding identified key concepts and categories from the qualitative data. Over 70% of students had favorable opinions of the learning experience and indicated that the speed and length of the video were appropriate. Highly positive and conflicting negative comments regarding the use of subtitles showed both preferences for subtitles over audio and vice versa. The use of a video resource was considered valuable as the replay and review functions allowed better visualization of the procedures, which was considered a good recap tool for the clinical demonstration. It was also a better revision aid than textbooks. So, if the students were able to view these videos at will, they believed that videos supplemented their self-study. Despite the positive response, videos were not considered to replace live clinical demonstrations. While students preferred live demonstrations over the clinical videos they did express a realization of these as a supplemental learning material for self-study based on their ease of access, use for revision, and prior to clinical preparation. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  17. Relationship between masticatory ability and physical performance in community-dwelling edentulous older adults wearing complete dentures.

    Science.gov (United States)

    Moriya, Shingo; Notani, Kenji; Miura, Hiroko; Inoue, Nobuo

    2014-12-01

    This study aimed to elucidate the association between masticatory ability and physical performance in community-dwelling edentulous older adults wearing complete dentures. Physical performance parameters are significant predictors of decreased activities of daily living. Previous studies have shown the relationships between oral conditions and these parameters. Here, we focused on complete denture wearers. Two hundred and ten edentulous adults aged ≥65 years and wearing complete dentures were enrolled. The following oral conditions were examined: masticatory ability measured by colour-changing chewing gum, number of foods considered chewable, pain when using dentures and denture base fit. Handgrip strength (HG) and one-leg standing time with eyes open (OLST) were used to evaluate muscle strength and static balance. Spearman's rank correlation coefficients were calculated to examine the correlations between oral conditions and physical performance. Forward stepwise linear regression models were applied with each physical performance parameters as the dependent variable and oral conditions as the independent variable. The women did not show significant correlations between oral conditions and the physical performance. In men, significant and positive correlations were found between the number of chewable foods and HG, and between the colour scores and OLST. The significant correlation between the colour scores and OLST was still noted in the stepwise liner regression analysis after adjusting for demographic, social and medical conditions, and other oral conditions. In Japanese elderly edentulous men wearing complete dentures, masticatory ability evaluated as the mixing ability may be associated with static balance. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  18. Evaluation of Team-Based Learning and Traditional Instruction in Teaching Removable Partial Denture Concepts.

    Science.gov (United States)

    Echeto, Luisa F; Sposetti, Venita; Childs, Gail; Aguilar, Maria L; Behar-Horenstein, Linda S; Rueda, Luis; Nimmo, Arthur

    2015-09-01

    The aim of this study was to evaluate the effectiveness of team-based learning (TBL) methodology on dental students' retention of knowledge regarding removable partial denture (RPD) treatment. The process of learning RPD treatment requires that students first acquire foundational knowledge and then use critical thinking skills to apply that knowledge to a variety of clinical situations. The traditional approach to teaching, characterized by a reliance on lectures, is not the most effective method for learning clinical applications. To address the limitations of that approach, the teaching methodology of the RPD preclinical course at the University of Florida was changed to TBL, which has been shown to motivate student learning and improve clinical performance. A written examination was constructed to compare the impact of TBL with that of traditional teaching regarding students' retention of knowledge and their ability to evaluate, diagnose, and treatment plan a partially edentulous patient with an RPD prosthesis. Students taught using traditional and TBL methods took the same examination. The response rate (those who completed the examination) for the class of 2013 (traditional method) was 94% (79 students of 84); for the class of 2014 (TBL method), it was 95% (78 students of 82). The results showed that students who learned RPD with TBL scored higher on the examination than those who learned RPD with traditional methods. Compared to the students taught with the traditional method, the TBL students' proportion of passing grades was statistically significantly higher (p=0.002), and 23.7% more TBL students passed the examination. The mean score for the TBL class (0.758) compared to the conventional class (0.700) was statistically significant with a large effect size, also demonstrating the practical significance of the findings. The results of the study suggest that TBL methodology is a promising approach to teaching RPD with successful outcomes.

  19. Efficacy of bone substitute material in preserving volume when placing a maxillary immediate complete denture: study protocol for the PANORAMIX randomized controlled trial.

    Science.gov (United States)

    Rignon-Bret, Christophe; Hadida, Alain; Aidan, Alexis; Nguyen, Thien-Huong; Pasquet, Gerard; Fron-Chabouis, Helene; Wulfman, Claudine

    2016-05-20

    Bone preservation is an essential issue in the context of last teeth extraction and complete edentulism. The intended treatment, whether a complete denture or an implant placement, is facilitated with a voluminous residual ridge. Bone resorption after multiple extractions has not been as well studied as the bone resorption that occurs after the extraction of a single tooth. Recent advances in bone substitute materials have revived this issue. The purpose of this study is to evaluate the interest in using bone substitute material to fill the socket after last teeth extraction in a maxillary immediate complete denture procedure compared with the conventional protocol without socket filling. A randomized, controlled, clinical trial was designed. The 34 participants eligible for maxillary immediate complete denture were divided into two groups. Complete dentures were prepared despite persistence of the last anterior teeth. The control group received a conventional treatment including denture placement immediately after extractions. In the experimental group, in addition to the immediate denture placement, a xenograft bone-substitute material (Bio-Oss Collagen®) was placed in the fresh sockets. The primary outcome of the study is to compare mean bone ridge height loss 1 year after maxillary immediate complete denture placement, with or without bone-substitute material, in incisor and canine sockets. The secondary outcomes are to compare the average bone ridge height and width loss for each extraction site. An original quantitative evaluation method using cone beam computed tomography was designed for reproducible measurements, with a radio-opaque denture duplicate. Two independent operators perform the radiologic measurements. The immediate complete denture technique limits bone resorption in multiple extraction situations and thus allows better denture retention and better options for implant placement. To compare the benefit of using any bone socket-filling material

  20. The functional deformation of maxillary complete dentures in patients with flabby alveolar ridges. Part II: After surgery.

    Science.gov (United States)

    el Ghazali, S; Nilner, K; Wallenius, K

    1991-01-01

    Using strain-gauged maxillary complete dentures, the effects of the surgical removal of soft mobile tissue over the maxillary edentulous alveolar ridges--flabby ridges--on the deformation pattern and magnitude of functional strain were studied in five subjects. The results showed that a 20-90% reduction in denture deformation had taken place after surgery. Furthermore, a pre-operative shear-straining pattern of the buccal flanges and the lateral palatal slopes was not evident post-operatively. The results of this study point on the beneficial value of early surgical removal of flabby maxillary alveolar ridges.

  1. In Vivo Comparison of the Masticatory Efficiency of Artificial Teeth with Two Different Cusp Heights in Complete Dentures: A Preliminary Study.

    Science.gov (United States)

    Barbosa, Wallace Ferreira; Iegami, Carolina Mayumi; Uehara, Priscila Nakasone; Furuyama, Ricardo Jun; Tamaki, Regina

    2017-04-01

    The goal of complete denture rehabilitation is to restore facial esthetics and masticatory function to edentulous patients. Several types of artificial teeth with different occlusal anatomy are available. Theoretically, teeth with a higher cusp height provide improved masticatory efficiency. The aim of this study was to compare the masticatory efficiency of complete denture wearers using artificial teeth with two cusp heights. Sixteen complete denture wearers were given complete dentures with Heraeus Premium teeth. Fifteen days after denture installation, a first masticatory efficiency test was performed with Optocal. A new pair of complete dentures with Dentsply Biotone teeth was then given to each participant to replace the first set. This second set was fabricated by duplicating the same models used to fabricate the first set of dentures. Fifteen days after installation of the dentures with Biotone teeth, a second masticatory efficiency test was performed with Optocal. On both tests, the comminuted material was treated and sieved through a stack of sieves under vibration. The content of each sieve was weighed, and the obtained data were tabulated. Statistical analysis was performed using the Kolmogorov-Smirnov and Wilcoxon tests. Mean and standard deviation of participants' masticatory efficiency, as measured by X50 particle size (mm), were 8.39 and 5.59 for dentures with Premium teeth, and 8.56 and 5.84 for dentures with Biotone teeth. According to the results, there were no differences (p complete denture sets using teeth with the two cusp heights. © 2015 by the American College of Prosthodontists.

  2. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

    Science.gov (United States)

    2017-01-01

    PURPOSE The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr–Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS Glass fiber mesh- and Cr–Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair. PMID:28243388

  3. The functional deformation of maxillary complete dentures in patients with flabby alveolar ridges. Part I: Before surgery.

    Science.gov (United States)

    el Ghazali, S; Nilner, K; Wallenius, K

    1991-01-01

    Using strain-guaged duplicate maxillary dentures, the deformation patterns and magnitude of functional strain were studied on five complete denture wearing subjects who had varying amounts of soft mobile tissue over their maxillary edentulous alveolar ridge so called flabby ridges. The thickness of mobile tissue--expressed as depth--was measured by a sharpened periodontal probe with aid of a plastic base plate as a locator. The functional test included maximum biting, and the chewing of three test food samples. The results did not point on any direct relationship between the thickness of the soft tissue and the midline deformation pattern and/or magnitude of functional strain. It seems, however, as if the main influence of mobile tissue is on the strain behaviour in the lateral part of the denture.

  4. Mandibular bone resorption in patients treated with tissue-integrated prostheses and in complete-denture wearers

    Energy Technology Data Exchange (ETDEWEB)

    Sennerby, L.; Carlsson, G.E.; Bergman, B.; Warfvinge, J.

    1988-01-01

    Mandibular bone resorption was studied in patients treated with tissue-integrated prostheses (TIP) and in complete-denture wearers by distance and area measurements on cephalometric radiographs. The area measurements were performed by means of a computer. Two TIP groups with short and long periods (average chi=2.4 and 23.9 years) of edentulousness, and wearing complete dentures before fixture installtion, were followed up to over 7-8 years. Mandibular bone resorption was remarkably small behind the distally positioned fixtures in comparison with the correspondings region in complete-denture wearers. Patients with complete dentures showed a continous resorption of the mandibular alveolar ridge over 21 years, even though there were great individual variations. The bone loss was most pronounced anteriorly and during the first 2 years after extraction of the residual teeth. It is concluded that treatment with tissue-integrated prostheses seems to reduce bone resorption in the mandible, probably owing to favorable load conditions and adequate stimulation of the bone.

  5. COMPARISON OF INTERFACIAL SURFACE TENSION AND CAPILLARITY OF MAXILLARY COMPLETE DENTURES, FABRICATED BY CONVENTIONAL CUVETTE TECHNIQUE AND INJECTION MOLDING TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Kalina Georgieva

    2016-09-01

    Full Text Available Purpose: The purpose of this in vivo study is to register the forces necessary to displace maxillary complete dentures fabricated by compression molding and injection molding techniques on one and the same patient and to compare the interfacial surface tension and capillarity which are achieved by both techniques. Material/Methods: Two maxillary complete dentures are made for each patient (total number of patients is 30 using both technologies. The magnitude of dislodging force is measured by a dynamometer. Results: Mean ± standard deviation for conventional cuvette technique is 17,53N ± 12,11N. Mean ± standard deviation for injection molding technique is 20,73N ± 13,89N. Analysis of variance (ANOVA revealed statistically significant differences in results achieved by conventional cuvette technique and injection molding technology. The results of injection technique were higher than those of compression molding technique (F=123,676, p< 0,001. Conclusions: Based on the results we suggest a standard for dislodging force of maxillary complete dentures fabricated by conventional cuvette technique- 13N, and by injection molding technology-15,5N. These values would guarantee good interfacial surface tension and capillarity. The injection molding technique was found to produce better fitting maxillary complete dentures when compared to compression molding technique. This would ensure better retention, less traumatic manifestations after insertion and higher patient’s comfort and satisfaction.

  6. The base processing of complete denture%全口义齿的基托成型

    Institute of Scientific and Technical Information of China (English)

    吴国锋; 邓再喜

    2012-01-01

    全口义齿基托成型关系到义齿基托加工精度.基托成型传统采用装盒法,通过装盒、烫盒、冲蜡、充填树脂、压盒、热处理、出盒、磨光等步骤将义齿基托蜡型替换成树脂基托.注塑法是另外一种义齿基托成型技术,制作过程简便,加工精度更高,并且能够保存无牙颌石膏模型,但是需要特殊设备.本文详细描述了上述2种临床基托成型技术,并且比较了两者的优缺点.%The base processing of complete denture plays the important role for the definitive precision of complete denture. Traditionally the base processing employs the cartooning method to replace the wax by dental resin, whose major steps include boxing, flanking, resin-filling, heat treatment, and so on. Recently another method was introduced to produce resin base with injection moulding, which can avoid the occurrence of the mistakes of traditional methods and simplify the process. Special laboratory appliances are required for this manufacture method. This article illustrates and describes the above two methods, the merits and faults of each method are also discussed.

  7. Positional change of the condylar heads after wearing complete denture on dental cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Ho; Kim, Jae Duk; Chung, Chae Heon [Department of Dental Science Graduate School and Oral Biology Research, Chosun University, Gwangju (Korea, Republic of)

    2008-03-15

    The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB Mercuray{sup TM} (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with Vimplant2.0{sup TM} (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p<0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was 79.6 {+-} 2.7 .deg. C and 80.1 {+-} 5.7 .deg. C respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.

  8. Effects of glass fiber mesh with different fiber content and structures on the compressive properties of complete dentures.

    Science.gov (United States)

    Yu, Sang-Hui; Cho, Hye-Won; Oh, Seunghan; Bae, Ji-Myung

    2015-06-01

    No study has yet evaluated the strength of complete dentures reinforced with glass fiber meshes with different content and structures. The purpose of this study was to compare the reinforcing effects of glass fiber mesh with different content and structures with that of metal mesh in complete dentures. Two types of glass fiber mesh were used: SES mesh (SES) and glass cloth (GC2, GC3, and GC4). A metal mesh was used for comparison. The complete dentures were made by placing the reinforcement 1 mm away from the tissue surface. A control group was prepared without any reinforcement (n=10). The compressive properties were measured by a universal testing machine at a crosshead speed of 5 mm/min. The results were analyzed with the Kruskal-Wallis test and the Duncan multiple range test (α=.05). The fracture resistance of the SES group was significantly higher than that of the control, GC4, and metal groups (asymptotic P=.004), but not significantly different from the GC2 and GC3 groups. The toughness of the SES and GC3 groups was significantly higher than that of the others (asymptotic Pcomplete dentures. The content of the glass fiber mesh seemed more important than the structures. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Successful Fitting of a Complete Maxillary Denture in a Patient with Severe Alzheimer's Disease Complicated by Oral Dyskinesia

    Science.gov (United States)

    Hashimoto, Akie; Inoue, Ryosuke; Yoshimoto, Shohei; Hirofuji, Takao

    2016-01-01

    There is an increasing population of elderly patients suffering from Alzheimer's disease (AD), the most common form of dementia. In dentistry, a critical problem associated with these patients is the use of a new denture, as AD patients often refuse dental management and are disturbed by minor changes in their oral environment. Some AD patients have further complications associated with oral dyskinesia, a movement disorder that can make dental management difficult, including the stability of a complete denture. In this case, we successfully fitted a complete maxillary denture using modified bilateral balanced occlusion after multiple tooth extractions under intravenous sedation in a 66-year-old woman with severe AD complicated by oral dyskinesia. Following treatment, her appetite and food intake greatly improved. Providing a well-fitting complete denture applied by modified bilateral balanced occlusion, which removes lateral interference using zero-degree artificial teeth for movement disorder of the jaw in patients with severe AD complicated by oral dyskinesia, helps improve oral function. PMID:27822393

  10. Alternative complete-arch cement-retained implant-supported fixed partial denture.

    Science.gov (United States)

    Hofstede, T M; Ercoli, C; Hagan, M E

    1999-07-01

    Early implant prostheses designs, which used screw-retained metal and acrylic resin structures, frequently left a space between the prosthesis and the soft tissue. Common deficiencies of this design included phonetic and esthetic problems and screw loosening. Cement-retained implant prostheses are also used in partially and completely edentulous patients, and are thought to have optimal occlusion and esthetics. Moreover, cement-retained prostheses may induce less stress on the implant, thereby maximizing the possibility of a passive fit. Porcelain fused to metal prostheses have been used mostly in partially edentulous situations. Recently, complete-arch porcelain fused to metal prostheses that replace hard and soft tissue have been used and, although this restoration can have excellent esthetics, there are disadvantages such as high cost, potential framework distortion during fabrication, and difficulty in repairing fractures of in-service porcelain. This article describes an alternative technique for the fabrication of a complete-arch, cement-retained, metal-acrylic resin implant-supported fixed partial denture. When compared with porcelain fused to metal complete-arch restorations, this prostheses is esthetic, has excellent retention and stability, yet is relatively inexpensive to fabricate, and requires less laboratory skill.

  11. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading.

    Science.gov (United States)

    Im, So-Min; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2017-02-01

    The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (Pdenture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

  12. [Quantitative evaluation of printing accuracy and tissue surface adaptation of mandibular complete denture polylactic acid pattern fabricated by fused deposition modeling technology].

    Science.gov (United States)

    Deng, K H; Wang, Y; Chen, H; Zhao, Y J; Zhou, Y S; Sun, Y C

    2017-06-09

    Objective: To quantitatively evaluate the adaptation of polylactic acid (PLA) pattern of mandibular complete denture fabricated by fused deposition modeling (FDM) technology. Methods: A mandibular complete denture digital model was designed through a complete denture design software based on a pair of standard maxillomandibular edentulous plaster model and their occlusion bases. Ten PLA mandibular complete dentures were printed with a FDM machine. The dentures were scanned with and without the plaster model using a three-dimensional (3D) scanner. In Geomagic software, the scanning data of printed dentures were registered to its computer aided design (CAD) data, and the printing error was analyzed using the multipoint registration command. For quantitatively evaluating the adaptation of the denture, the data of plaster model and PLA denture were registered to the whole data of denture located in the plaster model using the best-fit alignment command, the 3D deviation of the plaster model and tissue surface of the denture represent the space between them. The overall area was separated into three parts: primary stress-bearing area, secondary stress-bearing area and border seal area, and the average deviations of these three parts were measured. The values were analyzed using analysis of variance. Results: Compared with the CAD data, the printing error was (0.013±0.004) mm. The overall 3D deviation between PLA denture and plaster model was (0.164±0.033) mm, in which the primary stress-bearing area was (0.165± 0.045) mm, the secondary stress-bearing area was (0.153 ± 0.027) mm, the border seal area was (0.186 ± 0.043) mm. These showed a good fit in the majority parts of the FDM denture to the plaster model. No statistically significant difference was observed between the three areas (F=1.857, P=0.175>0.05). Conclusions: Combined with the 3D scanning, CAD and FDM technology, a FDM 3D printing process of complete denture for injection moulding can be established. As

  13. [Comparison of adaptation and microstructure of titanium upper complete denture base fabricated by selecting laser melting and electron beam melting].

    Science.gov (United States)

    Ye, Y; Xiong, Y Y; Zhu, J R; Sun, J

    2017-06-09

    Objective: To fabricate Ti alloy frameworks for a maxillary complete denture with three-dimensional printing (3DP) technique, such as selective laser melting (SLM) and electron beam melting (EBM), and to evaluate the microstructure of these frameworks and their adaptation to the die stone models. Methods: Thirty pairs of edentulous casts were divided into 3 groups randomly and equally. In each group, one of the three techniques (SLM, EBM, conventional technique) was used to fabricate Ti alloy frameworks. The base-cast sets were transversally sectioned into 3 sections at the distal of canines, mesial of first molars, and the posterior palatal zone. The gap between the metal base and cast was measured in the 3 sections. Stereoscopic microscope was used to measure the gap. Three pieces of specimens of 5 mm diameter were fabricated with Ti alloy by SLM, EBM and the traditional casting technology (as mentioned above). Scanning electron microscope (SEM) was used to evaluate the differences of microstructure among these specimens. Results: The gaps between the metal base and cast were (99.4±17.0), (98.2±26.1), and (99.6± 16.1) μm in conventional method; (99.4 ± 22.8), (83.1 ± 19.3), and (103.3 ± 13.8) μm in SLM technique; (248.3±70.3), (279.1±71.9), and (189.1±31.6) μm in EBM technique. There was no statistical difference in the value of gaps between SLM Ti alloy and conventional method Ti alloy group (P>0.05). There was statistical difference among EBM Ti alloy, conventional method Ti alloy and SLM Ti alloy group (Pcomplete denture. The mechanical properties and microstructure of the denture frameworks prepared by SLM indicate that these dentures are appropriate for clinical use. EBM technique is inadequate to make a complete denture now.

  14. Cost-effectiveness of silicone and alginate impressions for complete dentures.

    Science.gov (United States)

    Hulme, C; Yu, G; Browne, C; O'Dwyer, J; Craddock, H; Brown, S; Gray, J; Pavitt, S; Fernandez, C; Godfrey, M; Dukanovic, G; Brunton, P; Hyde, T P

    2014-08-01

    The aim of this study was to assess the cost effectiveness of silicone and alginate impressions for complete dentures. Cost effectiveness analyses were undertaken alongside a UK single centre, double blind, controlled, crossover clinical trial. Taking the perspective of the healthcare sector, effectiveness is measured using the EuroQol (EQ-5D-3L) which provides a single index value for health status that may be combined with time to produce quality adjusted life years (QALYs); and Oral Health Impact Profile (OHIP-EDENT). Incremental cost effectiveness ratios are presented representing the additional cost per one unit gained. Mean cost was higher in the silicone impression group (£388.57 vs. £363.18). Negligible between-group differences were observed in QALY gains; the silicone group had greater mean OHIP-EDENT gains. The additional cost using silicone was £3.41 per change of one point in the OHIP-EDENT. The silicone group was more costly, driven by the cost of materials. Changes in the EQ-5D and QALY gains over time and between arms were not statistically significant. Change in OHIP-EDENT score showed greater improvement in the silicone group and the difference between arms was statistically significant. Given negligible QALY gains and low level of resource use, results must be treated with caution. It is difficult to make robust claims about the comparative cost-effectiveness. Silicone impressions for complete dentures improve patients' quality of life (OHIP-EDENT score). The extra cost of silicone impressions is £30 per patient. Dentists, patients and health care funders need to consider the clinical and financial value of silicone impressions. Different patients, different dentists, different health funders will have individual perceptions and judgements. ISRCTN01528038. NIHR-RfPB grant PB-PG-0408-16300. This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental

  15. Cost-effectiveness of silicone and alginate impressions for complete dentures

    Science.gov (United States)

    Hulme, C.; Yu, G.; Browne, C.; O’Dwyer, J.; Craddock, H.; Brown, S.; Gray, J.; Pavitt, S.; Fernandez, C.; Godfrey, M.; Dukanovic, G.; Brunton, P.; Hyde, T.P.

    2014-01-01

    Objective The aim of this study was to assess the cost effectiveness of silicone and alginate impressions for complete dentures. Methods Cost effectiveness analyses were undertaken alongside a UK single centre, double blind, controlled, crossover clinical trial. Taking the perspective of the healthcare sector, effectiveness is measured using the EuroQol (EQ-5D-3L) which provides a single index value for health status that may be combined with time to produce quality adjusted life years (QALYs); and Oral Health Impact Profile (OHIP-EDENT). Incremental cost effectiveness ratios are presented representing the additional cost per one unit gained. Results Mean cost was higher in the silicone impression group (£388.57 vs. £363.18). Negligible between-group differences were observed in QALY gains; the silicone group had greater mean OHIP-EDENT gains. The additional cost using silicone was £3.41 per change of one point in the OHIP-EDENT. Conclusions The silicone group was more costly, driven by the cost of materials. Changes in the EQ-5D and QALY gains over time and between arms were not statistically significant. Change in OHIP-EDENT score showed greater improvement in the silicone group and the difference between arms was statistically significant. Given negligible QALY gains and low level of resource use, results must be treated with caution. It is difficult to make robust claims about the comparative cost-effectiveness. Clinical significance Silicone impressions for complete dentures improve patients’ quality of life (OHIP-EDENT score). The extra cost of silicone impressions is £30 per patient. Dentists, patients and health care funders need to consider the clinical and financial value of silicone impressions. Different patients, different dentists, different health funders will have individual perceptions and judgements. ISRCTN01528038. NIHR-RfPB grant PB-PG-0408-16300.

 This article forms part of a project for which the author (TPH) won the Senior Clinical

  16. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction

    Directory of Open Access Journals (Sweden)

    Alaa’a M. Salloum

    2016-01-01

    Conclusion: The study results indicate that the use of dental stone or a 50:50 mixture of plaster and stone for investing of dentures is an important factor in efforts to control the magnitude of tooth movement.

  17. Avaliação da estomatite protética em portadores de próteses totais Evaluation of denture stomatitis in users of complete dentures

    Directory of Open Access Journals (Sweden)

    Terezinha Rezende CARVALHO de OLIVEIRA

    2000-09-01

    Full Text Available As próteses muco-suportadas são consideradas facilitadoras em potencial da estomatite protética (EP, lesão comumente observada sob a base das próteses, caracterizada por aspectos eritematosos difusos ou pontilhados na mucosa de suporte. Sua etiologia é controversa, podendo estar relacionada principalmente a fatores locais. Diversos aspectos funcionais associam-se a estes fatores representados pela oclusão, dimensão vertical, retenção, estabilidade dinâmica e estática além de aspectos qualitativos relacionados às condições encontradas no desdentado. Foram levados em consideração o período de edentulismo, número e tempo de uso das próteses, uso contínuo, conservação, presença de placa e higiene bucal. Os fatores foram avaliados, visando esclarecer a possível relação dos aspectos funcionais e protéticos com a EP. Exame clínico foi realizado em 116 pacientes de ambos os sexos, desdentados bimaxilares, que utilizavam as duas próteses muco-suportadas, portadores ou não de estomatite protética (EP. Os resultados indicaram que a maioria dos pacientes examinados tinha EP frente ao menor número de pacientes sem EP, havendo nos dois grupos equivalência nos resultados da avaliação clínica e protética. Os fatores funcionais e qualitativos das próteses, avaliados isoladamente, não puderam ser considerados responsáveis pela ocorrência dessa patologia, constatando-se que um único fator protético não demonstrou, de per si, ser responsável pela presença da EP, embora possa ser um facilitador para o seu desenvolvimento.Functional and qualitative factors in complete dentures can contribute to the development of lesions in the oral mucosa. Such lesions are classified as denture stomatitis (DS. There are considerable differences of opinion as to its etiology, mainly related to systemic and local factors. The influence of functional and qualitative features of complete dentures on denture stomatitis was evaluated. The

  18. Erythematous oral candidiasis in patients with controlled type II diabetes mellitus and complete dentures.

    Science.gov (United States)

    Motta-Silva, Arlindo C; Aleva, Natanael A; Chavasco, Jorge K; Armond, Mônica C; França, Julieta P; Pereira, Luciano José

    2010-03-01

    Diabetes mellitus (DM) is a systemic condition characterized by a deficient sugar metabolism, which affects the immune system and favors the development of yeasts. The aim of the present study was to perform biochemical, morphological, exoenzyme analyses of Candida species and the molecular identification (DNA) of C. albicans in patients with type II diabetes mellitus. The exoenzyme quantification was compared to non-diabetic patients as controls. Two hundred and seventy-four patients who make use of complete dentures were evaluated, 28 of whom had diabetes and erythematous oral candidiasis. Other thirty patients presented the same clinical feature but without diabetes. Samples were isolated for biochemical identification (auxonogram), morphological identification (production of germ tubes) and PCR molecular identification (DNA). The capability of the Candida samples in producing phospholipases and proteinases was also determined. The diabetic patients had a greater diversity of Candida species (Fischer's exact test, P = 0.04). The production of proteinases by C. albicans in patients with diabetes was greater than in the control group (unpaired "t" test P 0.05). It was concluded that patients with controlled DM exhibited systemic conditions predisposing C. albicans proteinase increased production.

  19. A technique to stabilize record bases for Gothic arch tracings in patients with implant-retained complete dentures.

    Science.gov (United States)

    Raigrodski, A J; Sadan, A; Carruth, P L

    1998-12-01

    Clinicians have long expressed concern about the accuracy of the Gothic arch tracing for recording centric relation in edentulous patients. With the use of dental implants to assist in retaining complete dentures, the problem of inaccurate recordings, made for patients without natural teeth, can be significantly reduced. This article presents a technique that uses healing abutments to stabilize the record bases so that an accurate Gothic arch tracing can be made.

  20. Quantitative Evaluation of Tissue Surface Adaption of CAD-Designed and 3D Printed Wax Pattern of Maxillary Complete Denture

    Directory of Open Access Journals (Sweden)

    Hu Chen

    2015-01-01

    Full Text Available Objective. To quantitatively evaluate the tissue surface adaption of a maxillary complete denture wax pattern produced by CAD and 3DP. Methods. A standard edentulous maxilla plaster cast model was used, for which a wax pattern of complete denture was designed using CAD software developed in our previous study and printed using a 3D wax printer, while another wax pattern was manufactured by the traditional manual method. The cast model and the two wax patterns were scanned in the 3D scanner as “DataModel,” “DataWaxRP,” and “DataWaxManual.” After setting each wax pattern on the plaster cast, the whole model was scanned for registration. After registration, the deviations of tissue surface between “DataModel” and “DataWaxRP” and between “DataModel” and “DataWaxManual” were measured. The data was analyzed by paired t-test. Results. For both wax patterns produced by the CAD&RP method and the manual method, scanning data of tissue surface and cast surface showed a good fit in the majority. No statistically significant (P>0.05 difference was observed between the CAD&RP method and the manual method. Conclusions. Wax pattern of maxillary complete denture produced by the CAD&3DP method is comparable with traditional manual method in the adaption to the edentulous cast model.

  1. Evaluation of Denture Stomatitis in Croatian Adult Population

    OpenAIRE

    Ćelić, R.; Knezović Zlatarić, D.; Baučić, I.

    2001-01-01

    Denture stomatitis (DS) is often found under the removable partial dentures (RPDs). There are many factors influencing it, such as patient’s age and gender, smoking habits, denture age, denture material, denture wearing habits, denture hygiene habits, oral hygiene instruction, denture cleanness and denture plaque accumulation. The aim of this study was to find out the influence these factors have on the prevalence of DS under RPDs and complete dentures (CDs). A total of 200 pat...

  2. A comparison of three dimensional change in maxillary complete dentures between conventional heat polymerizing and microwave polymerizing techniques

    Directory of Open Access Journals (Sweden)

    Shinsuke Sadamori

    2007-03-01

    Full Text Available The purpose of this study was to measure and compare two different polymerizing processes, heat polymerizing (HP and microwave polymerizing (MP, on the three dimensional changes in the fitting surface and artificial teeth of maxillary complete dentures. A threedimensional coordinate measurement system was used to record distortion of the specimens. The distortion of the fitting surface was measured from the reference plane on the fitting side from which a coordinate system was set, and the movement of the artificial teeth and the distortion of the polished surface was measured from the reference plane of the artificial tooth side, from which a coordinate system was set. It was clearly showed that various distortions of denture specimens after polymerization process can be measured with this three-coordinate measuring machine. The study showed that the overall distortion of the fitting surface in HP specimens was shown to be larger than in MP ones.

  3. Evidence Regarding the Treatment of Denture Stomatitis.

    Science.gov (United States)

    Yarborough, Alexandra; Cooper, Lyndon; Duqum, Ibrahim; Mendonça, Gustavo; McGraw, Kathleen; Stoner, Lisa

    2016-06-01

    Denture stomatitis is a common inflammatory condition affecting the mucosa underlying complete dentures. It is associated with denture microbial biofilm, poor denture hygiene, poor denture quality, and nocturnal denture use. Numerous treatment methodologies have been used to treat stomatitis; however, a gold standard treatment has not been identified. The aim of this systematic review is to report on the current knowledge available in studies representing a range of evidence on the treatment of denture stomatitis.

  4. Effect of polymerization techniques on vertical dimension and tooth position in complete dentures.

    Science.gov (United States)

    Slaviero, Thiago V S; Simon, Gabriel H P; Tagliari, Ivânio; Busato, Priscila M R; Sinhoreti, Mario A C; Camilotti, Veridiana; Mendonça, Marcio J

    2011-01-01

    Due to the changes in the composition and processing of acrylic resins, it seems appropriate to evaluate the influence of polymerization methods about the alteration of occlusal vertical dimension and the horizontal positioning of artificial teeth of total dentures. For this, 64 specimens were made, simulating a maxillary total denture waxed from a standard maxillary denture. The experimental samples were divided into two groups: Group 1 - The resins were submitted to polymerization in a hot water bath, Group 2 - The same resins were submitted to poly-merization by microwave energy. The samples were measured horizontally and vertically before and after the polymerization process. Based on the results, it can be concluded that there was no statistically significant difference between the conventional polymerization method and the polymerization method by microwave, related to the stability of occlusal vertical dimension and horizontal positioning of artificial teeth on the specimens evaluated.

  5. A Randomized Crossover Trial Comparing Patient Preference for Mandibular Complete Dentures Made with Two Different Techniques: A Short-Term Follow-Up.

    Science.gov (United States)

    Geerts, Greta Avm

    The objective of this trial was to compare short-term patient preference for two mandibular complete denture (CD) fabrication techniques: neutral zone (NZ) and conventional (CV). A prospective, within-subject, randomized crossover trial was performed on a sample of 37 edentulous patients with complete denture experience. Two new sets of CDs were made for each patient, one set with a CV and one with a NZ mandibular denture. After consecutively wearing each set for at least 2 months after the last adjustment visit, patients indicated their preference (CV, NZ, or none). Associations and comparisons were made using the generalized linear model (GLM) and Fisher exact test between preference and sex, age, period of edentulousness, tissue quality, prosthodontic diagnostic index (PDI), and oral health-related quality of life (OHRQoL) differences of the two interventions assessed using the 20-item oral health impact profile (OHIP-20). Significance was determined at P = .05. A total of 15 (40%) patients preferred NZ, 8 (22%) preferred CV dentures, and 14 (38%) had no preference. Although more women preferred NZ over CV dentures (50% versus 27%), difference in preference according to sex was not significant (P = .359). Neither was difference in preference and PDI scores significant (P = .603). Preference could not be strongly associated to period of edentulousness, age, tissue scores, and differences in OHIP-20 scores (P > .05), except for OHIP-20 scores and NZ preference (P denture. These reasons were identified for both types of denture. Appearance and speech were not identified as reasons for a particular preference. Based on preference expressed by patients, there is no difference between NZ and CV mandibular dentures. Denture preference could not be related to patient variables over the study's time frame.

  6. Antimicrobial activity of complete denture cleanser solutions based on sodium hypochlorite and Ricinus communis - a randomized clinical study.

    Science.gov (United States)

    Salles, Marcela Moreira; Badaró, Maurício Malheiros; Arruda, Carolina Noronha Ferraz de; Leite, Vanessa Maria Fagundes; Silva, Cláudia Helena Lovato da; Watanabe, Evandro; Oliveira, Viviane de Cássia; Paranhos, Helena de Freitas Oliveira

    2015-01-01

    To preserve oral health and to maintain the prosthetic devices, it is important not only to improve the properties of commonly known hygiene products, but also to investigate new materials with antimicrobial action. Objectives This study evaluated the antimicrobial activity of sodium hypochlorite (0.25% and 0.50%) and 10% Ricinus communis' solutions against specific microorganisms. Sixty four maxillary complete denture wearers were instructed to brush their dentures three times a day and to soak them (20 min/day) in the solutions: SH1: 0.25% sodium hypochlorite; SH2: 0.5% sodium hypochlorite; RC: 10% R. communis oil; and C: 0.85% saline (control). The solutions were used for 7 days in a randomized sequence. Following each period of use, there was a 1-week washout period. Antimicrobial activity was determined by Colony Forming Units (CFU) counts of Streptococcus mutans, Candida spp., and gram-negative microorganisms. For collecting biofilm, the internal surface of maxillary dentures was brushed with saline solution, and biofilm suspension obtained. After dilutions (100 - 10-3), aliquots were seeded in Mitis salivarius, CHROMagar Candida, and MacConkey agar for detecting S. mutans, Candida spp., or gram-negative microorganisms, respectively. After incubation, colonies were counted, and CFU/mL values were calculated. Then, transformation - log10 (CFU+1) - data were analyzed using the Friedman test (α=0.05). Results showed significant differences between the solutions (p<0.001). All three solutions showed antimicrobial activity against S. mutans. Against Candida spp., RC and SH1 solutions showed similar effect while SH2 showed superior activity. SH1 and SH2 solutions showed antimicrobial action against gram-negative microorganisms. The Candida species most frequently isolated was C. albicans, followed by C. tropicalis and C. glabrata. The 0.5% sodium hypochlorite solution was the most effective and might be used to control denture biofilm. C. albicans was the most

  7. The association of responsiveness in oral and general health-related quality of life with patients' satisfaction of new complete dentures.

    Science.gov (United States)

    Kuo, Hsiao-Ching; Kuo, Ying-Se; Lee, I-Chen; Wang, Jen-Chyan; Yang, Yi-Hsin

    2013-09-01

    The objective was to determine the responsiveness properties of the Oral Health Impact Profile (OHIP) short-forms and 36-item Short-Form (SF-36) in complete denture treatment, and further to evaluate the association between patients' satisfaction and improvements in oral and general health-related quality of life (OHRQoL and HRQoL) after fitting of new, complete dentures. Study data were obtained from the 'Dentures for the Elders through Public Funding' study conducted in Kaohsiung County. A total of 224 subjects received denture treatments with 6-month follow-up and pre-/post-treatment interviews by questionnaire. The OHIP and SF-36 were used to measure OHRQoL and HRQoL. In addition, specific questions investigating seven aspects of patients' satisfaction were used to measure the patients' perceptions of complete denture success. The responsiveness of all outcome measures and their dimensions were assessed by effect size (ES). Multivariable analysis was used to examine the association between patients' satisfaction and OHIP/SF-36 while adjusting for demographic characteristics. There were improvements with regard to the 'physical pain' (ES = 0.19) and 'psychological discomfort' (ES = 0.42) dimensions of the Taiwanese short-form OHIP (OHIP-14T) after new complete denture treatment, but only improvement in the 'general health' (ES = 0.17) dimension in the SF-36 measure. Patients satisfied with 'comfort' and 'ease of cleaning' of their new dentures were significantly associated with the improvement of the OHIP-49 and OHIP-14T. This study suggests that denture treatments are associated with improvements of OHRQoL, but not in HRQoL. Furthermore, patients' satisfaction was significantly associated with responsiveness of OHRQoL but less significantly associated with responsiveness of HRQoL.

  8. Magnet retained cheek plumper in complete denture esthetics: a case report.

    Directory of Open Access Journals (Sweden)

    Suryakant Chhagan Deogade

    2014-02-01

    Full Text Available This clinical report describes a technique to improve support for sunken cheeks using magnet retained detachable acrylic cheek plumpers. The new generation of magnets with improved technology provides sufficient denture retention for clinical application. However, further follow-up may be necessary to ascertain the long-term usefulness of the magnet-retained prosthesis, because of corrosion and further loss of magnetism.

  9. The effect of new complete denture fabrication and simplified dietary advice on nutrient intake and masticatory function of edentulous elderly: A randomized-controlled trial.

    Science.gov (United States)

    Suzuki, Hiroyuki; Kanazawa, Manabu; Komagamine, Yuriko; Iwaki, Maiko; Jo, Ayami; Amagai, Noriko; Minakuchi, Shunsuke

    2017-08-05

    Combination of new complete denture fabrication and tailored dietary counseling is necessary to improve nutrient intake of the edentulous elderly. However, there is no evidence on the effect of simple dietary advice combined with new complete denture fabrication on the nutrient intake of the edentulous elderly. The aim of this study was to clarify the combined effect of new complete denture fabrication and simple dietary advice, using a uniform pamphlet, on the nutrient intake and masticatory function of edentulous elderly. The null hypothesis was that there would be no difference in the nutrient intake and masticatory function between edentulous elderly patients provided with simple dietary advice and new complete dentures and those provided with new dentures alone. A double-blind, randomized-controlled, parallel clinical trial was performed on the healthy edentulous elderly who were required to fabricate a new pair of complete denture. The participants were randomly divided into two groups, and each group received different advice: the intervention group received simple dietary advice using a uniform pamphlet, whereas the control group received denture care advice. During the process of new complete denture fabrication, two 20-min one-on-one advice sessions were conducted by a dentist. The primary outcome of this trial was protein intake, which was calculated from the responses in the brief-type self-administered diet history questionnaire (BDHQ). Secondary outcome was masticatory function, which was measured with a color-changeable chewing gum and a test gummy jelly. Outcome assessment was conducted twice, at baseline and at 3 months post-treatment. Among 70 participants who were randomized, 62 completed this trial. Protein intake in the intervention group significantly increased compared with that in the control group. Masticatory function was not significantly different between groups, but significantly increased at 3 months post-treatment compared with the

  10. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes.

    Science.gov (United States)

    Bidra, Avinash S; Farrell, Kimberly; Burnham, David; Dhingra, Ajay; Taylor, Thomas D; Kuo, Chia-Ling

    2016-05-01

    Presently, no studies have evaluated clinical outcomes or patient-centered outcomes for complete dentures fabricated with computer-aided design and computer aided manufacturing (CAD/CAM) technology. The purpose of this prospective cohort pilot study was to evaluate the clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated in 2 visits. Twenty participants with an existing set of maxillary complete dentures opposing either mandibular complete dentures or implant-retained overdentures that required replacement were recruited in this study. A 2-visit duplicate denture protocol was used to fabricate 40 arches of monolithic dentures with CAD/CAM technology. A 100-mm visual analog scale (VAS) instrument was then used to record 12 outcomes at baseline and at 1-year follow-up. Predetermined values were assigned to grade the VAS rating of each outcome as favorable (70.1-100) and unfavorable (≤70). Favorable ratings were sub-divided as excellent (90.1-100), good (80.1-90), and fair (70.1-80). The clinical outcomes were evaluated independently by 2 experienced prosthodontists at baseline and at 1-year follow-up. Patients evaluated the corresponding patient-centered outcomes during the same time intervals. Additional descriptive variables were also recorded. Each clinical and patient-centered outcome was summarized by medians and ranges. Differences in all ratings recorded at baseline and at 1 year were tested by 1-sided sign test (α=.05). Of 20 participants, 3 were lost to follow-up, and 3 were unsatisfied with the digital dentures and withdrew from the study. These 3 participants were considered treatment failures. Of the 14 remaining participants, 9 had implant-retained mandibular overdentures, and 5 had conventional mandibular complete dentures. For clinical outcomes, the 12 studied outcomes were favorably evaluated by the 2 prosthodontist judges at the 1-year follow-up. Evaluations showed minimal differences between baseline and 1 year. An

  11. Application of technique for duplicating denture in complete denture phonetic evaluation%复制义齿技术在研究全口义齿语音功能中的应用

    Institute of Scientific and Technical Information of China (English)

    李群; 郑东翔; 何华伟

    2014-01-01

    目的:探讨应用复制义齿技术制作全口义齿,并分析初戴前后义齿基托对语音功能的影响。方法:选取符合纳入标准的患者,采用复制义齿技术基托置换的方法制作全口义齿,以患者主观自评和客观的汉语语音清晰度方法,分别测试3种基托全口义齿在初戴前、后的语音功能。结果:应用复制义齿技术可以减少影响研究义齿发音的因素;3组义齿初戴时,语音清晰程度统计分析结果,塑胶基托与金属基托间差异有统计学意义(P<0.05),钴铬和纯钛基托两组间无明显差异。结论:义齿基托厚度较基托材质对患者语音功能的影响更大,患者的主观感觉与实际语音功能恢复有时并不一致。%Objective:To describe a duplicating technique for complete denture and evaluate the effect of different palatal bases on the speech sound in patients wearing these dentures. Methods:In the study, the dentures were made by the copy denture technique, and divided into a pure Titanium group, a PMMA group and a cobalt-chormium group. Using the patient's self-judgment and the measurement of Chinese intelligibility, the voice features of the complete dentures with different bases were tested when denture was placed in the mouth at the beginning. Results: The data of Chinese intelligibility showed significant differences between the metal groups and the plastic groups at the beginning of placement. Significant differences were found between the metal groups and the plastic groups (P<0.05), while the complete denture with titanium palatal plate was shown to be similar to the cobalt-chormium group. Conclusion: It is the thickness of the denture base other than the actual material that is likely to have greater impact on the recovery of patient’s phonetic function.

  12. Patient satisfaction and oral health-related quality of life after treatment with traditional and simplified protocols for complete denture construction.

    Science.gov (United States)

    Nuñez, Margaret C O; Silva, Donizete C; Barcelos, Bento A; Leles, Cláudio R

    2015-12-01

    The objective of this randomised controlled clinical trial study was to compare the effectiveness of a traditional and a simplified protocol for construction of conventional CD. The replacement of conventional dentures can result in potential functional and aesthetic benefits to the patient. Previous studies suggest that simplified procedures for complete dentures (CD) construction achieve results similar to the traditional methods. Fifty patients were randomly divided into two equal groups, traditional protocol (T group) and simplified protocol (S group). Treatment outcomes were assessed before the insertion of the new dentures and 30 days and 6 months after the last adjustment. It included measurements of quality of life related to oral conditions measured by the Brazilian version of OHIP-Edentulous scale and patients' satisfaction with the upper and lower dentures using a visual analogue scale (VAS), which combines the patient's perception in relation to overall satisfaction with the comfort, stability, ability to chew, ability to talk and aesthetics. The results showed significant reduction in negative impacts of oral conditions on quality of life and improved satisfaction with the upper and lower dentures (p dentures, there were no differences between the traditional and simplified protocols (p > 0.05). It was concluded that the simplified protocol results in patent's perception of treatment outcomes similar to the traditional protocol. © 2013 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  13. The effect of a new denture adhesive on bite force until denture dislodgement

    NARCIS (Netherlands)

    Ozcan, M.; Kulak, Y.; de Baat, C.; Arikan, A.; Ucankale, M.

    2005-01-01

    : PURPOSE: Denture adhesives are used to improve the denture retention and comfort of complete denture wearers. The purpose of this investigation was to establish the effect of a new denture adhesive on maximum bite force until denture dislodgement (BFDD) after adhesive application. MATERIALS AND

  14. The effect of a new denture adhesive on bite force until denture dislodgement

    NARCIS (Netherlands)

    B. Özcan (Behiye); Y. Kulak (Yasemin); C. de Baat; A. Arikan (Ayla); M. Ucankale (Mert)

    2005-01-01

    textabstractPurpose: Denture adhesives are used to improve the denture retention and comfort of complete denture wearers. The purpose of this investigation was to establish the effect of a new denture adhesive on maximum bite force until denture dislodgement (BFDD) after adhesive application.

  15. Selection patterns of dietary foods in edentulous participants rehabilitated with maxillary complete dentures opposed by mandibular implant-supported prostheses: a multicenter longitudinal assessment.

    Science.gov (United States)

    Tajbakhsh, Sharareh; Rubenstein, Jeffrey E; Faine, Mary P; Mancl, Lloyd A; Raigrodski, Ariel J

    2013-10-01

    Documentation of long-term changes in food intake is lacking for those treated with a maxillary complete denture opposed by a mandibular, screw-retained, implant-supported fixed prosthesis. The purpose of this study was to evaluate the selection patterns of dietary foods over 5 years for edentulous participants treated in a multicenter prospective clinical trial that compared cast alloy versus laser-welded titanium frameworks of an implant-supported prostheses opposed by maxillary complete dentures to rehabilitate edentulous participants. The study assessed data from a multicenter prospective clinical trial that followed edentulous participants from an initial baseline of wearing existing complete dentures to implant placement, restoration with a mandibular implant-supported prosthesis opposed by a maxillary complete denture, to follow-up assessment of these treatments over 5 years. The 32 participants in the cohort were treated at 5 of 9 participating centers. The data collected included 2 dietary forms, a standardized 4-day food diary form, and a dietary habits questionnaire. Each participant completed forms before entering into treatment (control) and at the 1- and 5-year follow-up assessment after being treated with a maxillary complete denture opposing a mandibular complete-arch fixed implant-supported prosthesis. Descriptive statistics were calculated for each measure at each assessment point. Regression analysis and the Sign test were used to calculate change in the participants' nutritional status (α=.05). Among the findings, it was noted that difficulty in masticating hard, raw, and fibrous foods decreased and intake of vegetable portions increased significantly from 2.5 to 3.3 servings. Participant comfort in eating in public places and their enjoyment of eating were significantly improved from 50% of participants being uncomfortable with their prior complete denture treatment to only 4% after 5 years. Within the limitations of this study, it was

  16. Prosthetic rehabilitation with collapsible hybrid acrylic resin and permanent silicone soft liner complete denture of a patient with scleroderma-induced microstomia.

    Science.gov (United States)

    Singh, Kunwarjeet; Gupta, Nidhi; Gupta, Ridhimaa; Abrahm, Dex

    2014-07-01

    Scleroderma is an autoimmune multisystem rheumatic condition characterized by fibrosis of connective tissues of the body, resulting in hardening and impairment of the function of different organs. Deposition of collagen fibers in peri-oral tissues causes loss of elasticity and increased tissue stiffness, resulting in restricted mouth opening. A maximal oral opening smaller than the size of a complete denture can make prosthetic treatment challenging. Patients with microstomia who must wear removable dental prostheses (RDPs) often face the difficulty of being unable to insert or remove a conventional RDP. A sectional-collapsible denture is indicated for the prosthetic management of these patients, but reduced manual dexterity often makes intraoral manipulation of the prosthesis difficult. A single collapsible complete denture is a better choice for functional rehabilitation of these patients. This clinical report describes in detail the prosthodontic management of a maxillary edentulous patient with restricted mouth opening induced by scleroderma with a single collapsible removable complete denture fabricated with heat-polymerized silicone soft liner and heat-cured acrylic resin. The preliminary and secondary impressions were made with moldable aluminum trays by using putty and light-body poly(vinyl siloxane) elastomeric impression material. The collapsed denture can be easily inserted and removed by the patient and also provides adequate function in the mouth.

  17. Restoring dentate appearance: a literature review for modern complete denture esthetics.

    Science.gov (United States)

    Waliszewski, Michael

    2005-04-01

    Despite the fact that solutions to functional and comfort problems are often available, successfully restoring the appearance of an edentulous patient remains a challenge. This review of the literature demonstrates the limited amount of useful evidence-based information available for restoration of dentate appearance in edentulous individuals. The English language peer-reviewed literature from 1880 to the present was reviewed. Articles were identified through previous literature reviews, an extensive hand search, and a search of MEDLINE using the key words esthetics and denture esthetics. Three main areas of information were found: published guidelines for achieving natural appearance, patient preference studies, and studies that have collected and analyzed anatomic norms.

  18. Antimicrobial activity of complete denture cleanser solutions based on sodium hypochlorite and Ricinus communis – a randomized clinical study

    Science.gov (United States)

    SALLES, Marcela Moreira; BADARÓ, Maurício Malheiros; de ARRUDA, Carolina Noronha Ferraz; LEITE, Vanessa Maria Fagundes; da SILVA, Cláudia Helena Lovato; WATANABE, Evandro; OLIVEIRA, Viviane de Cássia; PARANHOS, Helena de Freitas Oliveira

    2015-01-01

    ABSTRACT To preserve oral health and to maintain the prosthetic devices, it is important not only to improve the properties of commonly known hygiene products, but also to investigate new materials with antimicrobial action. Objectives This study evaluated the antimicrobial activity of sodium hypochlorite (0.25% and 0.50%) and 10% Ricinus communis’ solutions against specific microorganisms. Material and Methods Sixty four maxillary complete denture wearers were instructed to brush their dentures three times a day and to soak them (20 min/day) in the solutions: SH1: 0.25% sodium hypochlorite; SH2: 0.5% sodium hypochlorite; RC: 10% R. communis oil; and C: 0.85% saline (control). The solutions were used for 7 days in a randomized sequence. Following each period of use, there was a 1-week washout period. Antimicrobial activity was determined by Colony Forming Units (CFU) counts of Streptococcus mutans, Candida spp., and gram-negative microorganisms. For collecting biofilm, the internal surface of maxillary dentures was brushed with saline solution, and biofilm suspension obtained. After dilutions (100 - 10-3), aliquots were seeded in Mitis salivarius, CHROMagar Candida®, and MacConkey agar for detecting S. mutans, Candida spp., or gram-negative microorganisms, respectively. After incubation, colonies were counted, and CFU/mL values were calculated. Then, transformation - log10 (CFU+1) - data were analyzed using the Friedman test (α=0.05). Results showed significant differences between the solutions (p<0.001). Results All three solutions showed antimicrobial activity against S. mutans. Against Candida spp., RC and SH1 solutions showed similar effect while SH2 showed superior activity. SH1 and SH2 solutions showed antimicrobial action against gram-negative microorganisms. The Candida species most frequently isolated was C. albicans, followed by C. tropicalis and C. glabrata. Conclusions The 0.5% sodium hypochlorite solution was the most effective and might be used to

  19. Correlation of previous experience, patient expectation and the number of post-delivery adjustments of complete dentures with patient satisfaction in a Brazilian population.

    Science.gov (United States)

    Gaspar, M G; Dos Santos, M B F; Dos Santos, J F F; Marchini, L

    2013-08-01

    A number of variables may influence the outcome of complete denture therapy. The objective of this study was to verify possible correlations between previous experience with dentures, patient expectation and the number of post-delivery adjustments with patient satisfaction after treatment. One hundred patients (mean age 61·9 ± 10·3) rated their previous experiences with complete dentures and their expectations before and satisfaction after treatment on a visual analogue scale (VAS) using scores from 0 (worst results) to 10 (best results). The number of post-delivery adjustments and other patient-related clinical variables was also noted. Patient expectation scores were higher than previous experience scores and satisfaction after treatment scores. Positive and weak correlations were found between previous chewing experiences with complete dentures, with regard to chewing expectations and comfort of use. Phonetics and comfort of use in previous experiences presented a positive correlation with expectations for chewing, aesthetics, phonetics and comfort of use. Groups of patients with different levels of education presented significant differences in expectation scores regarding comfort of use as well. A negative and weak correlation was found between phonetics satisfaction and the number of post-delivery adjustments. Patients' expectations for the therapy were higher than their satisfaction after treatment. Previous experiences with complete dentures could slightly influence patients' expectations and satisfaction, whereas lower scores for previous experience with complete dentures caused lower scores for both expectation and satisfaction. Patients' educational levels and the number of post-delivery adjustments influenced negatively the expectations about comfort of use and patient satisfaction, respectively. © 2013 John Wiley & Sons Ltd.

  20. Speech intelligibility enhancement through maxillary dental rehabilitation with telescopic prostheses and complete dentures: a prospective study using automatic, computer-based speech analysis.

    Science.gov (United States)

    Knipfer, Christian; Bocklet, Tobias; Noeth, Elmar; Schuster, Maria; Sokol, Biljana; Eitner, Stephan; Nkenke, Emeka; Stelzle, Florian

    2012-01-01

    A completely edentulous or partially edentulous maxilla involving missing anterior teeth may impact speech production and lead to reduced speech intelligibility. The aim of this study was to prospectively evaluate the effect of a dental prosthetic rehabilitation on speech intelligibility in patients with a toothless or interrupted maxillary arch by means of an automatic, standardized speech recognition system. The speech intelligibility of 45 patients with complete tooth loss or a loss including missing anterior teeth in the maxilla was evaluated by means of a polyphone-based automatic speech recognition system that assessed the percentage of correctly recognized words (word accuracy). To replace inadequate maxillary removable dentures, 20 patients from the overall sample had been rehabilitated with complete dentures and 25 patients with telescopic prostheses. Speech recordings were made in four recording sessions (with and without existing prostheses and then at 1 week and 6 months after placement of newly fabricated prostheses). Significantly higher speech intelligibility was observed in both patient groups compared to the original results without the dentures inserted. After 6 months of adaptation, both groups had reached a level of speech quality that was comparable to the healthy control group. However, patients receiving new telescopic prostheses showed significantly higher levels of speech intelligibility compared to those receiving new complete dentures. Within 6 months, speech intelligibility did not significantly improve from the level found 1 week after insertion of new prostheses for both groups. Patients benefit from the fabrication of new dentures in terms of speech intelligibility, regardless of the type of prosthesis. However, telescopic crown prostheses yield significantly better speech quality compared to complete dentures.

  1. A preliminary study of the occlusal ;contact of complete denture%全口义齿患者咬合接触特征初探

    Institute of Scientific and Technical Information of China (English)

    贺淑贞; 王丁

    2014-01-01

    Objective To evaluate the occlusal contact characteristics of complete denture.Methods Twenty edentulous patients were involved in this study and were restored with complete dentures.After they were satisfied with the dentures,the patients occlusions were analyzed with T-ScanIII system.The occlusion time ,posterior occlusal contact point and bite distribution degree of balance were recorded and compared with the occlusion of twerty-two normal person. Results The occlusion time of twenty evaluate patients is 0.858±0.619,more than the group ofnormal occlusion(P0.05)。结论全口义齿患者的功能咬合接触特征与正常合的T-Scan表现有一定差异,有其独有特征。

  2. Use of transitional implants for immediate loading in mandibular complete dentures- A case report

    Directory of Open Access Journals (Sweden)

    Seema Bhoosreddy

    2009-01-01

    Full Text Available After the placement of implants in areas in which several teeth have been lost, both the clinician and the patient face many difficulties, particularly during healing. If no prosthesis is provided, the patient′s quality of life suffers. If a removable prosthesis is provided for optimum mastication and speech, many complicated adjustments of the denture may become necessary during healing, and the possibility of osseointegration failure increases. It has been reported that for implants to become osseointegrated, they must heal in the absence of functional loads for 4 to 6 months. To address the need for undisturbed healing and patient demand for uninterrupted immediate function and esthetics, the transitional implant system has been developed. This case report describes the use of transitional implants to support a removable mandibular overdenture. The transitional implant system is a sound and economical method of immediate patient restoration that allows for the protected healing of submerged implants.

  3. Restoration of facial symmetry in a patient with bell palsy using a modified maxillary complete denture: a case report.

    Science.gov (United States)

    Bagchi, Gautam; Nath, Dilip Kumar

    2012-01-01

    Permanent facial paralysis can be devastating for a patient. Modern society's emphasis on appearance and physical beauty contributes to this problem and often leads to isolation of patients embarrassed by their appearance. Lagophthalmos with ocular exposure, loss of oral competence with resultant drooling, alar collapse with nasal airway obstruction, and difficulties with mastication and speech production are all potential consequences of facial paralysis. Affected patients are confronted with both a cosmetic defect and the functional deficits associated with loss of facial nerve function. In this case history report, a modified maxillary complete denture permitted a patient with Bell palsy to carry on daily activities with minimal facial distortion, pain, speech difficulty, and associated emotional trauma.

  4. MICROECOLOGY OF THE MUCOUS MEMBRANE OF THE ALVEOLAR RIDGES IN THE PERIOD OF ADAPTATION TO COMPLETE DENTURES

    Directory of Open Access Journals (Sweden)

    Yanishen I. V.,

    2016-06-01

    Full Text Available Introduction. The oral cavity is an open ecosystem for various microorganisms and is one of the most populated biotopes of human. Removable dental prosthesis creates favorable conditions for the breeding of various microorganisms, including fungi. Stomatitis of dentition (SOD refers to a group of the most frequent pathologies of the mucous membranes of the oral cavity inflammatory character, due to the presence of the patient's dental prosthesis. For the prevention of SOD due to removable prostheses are used proper hygiene of dental prostheses, manufacture of technologically optimal designs of dentures, the shielding of the prosthesis and the use of cushioning materials. In this regard, the aim of this work was to study the dynamics characteristics of the microbiota of the mucous membranes of the oral cavity when performing prosthetic rehabilitation of patients with complete removable acrylic dentures with the use of adhesive and without its use. Materials and methods. The formation of the clinical groups of the patients occurred according to the following criteria: the study group comprised 23 patients with complete edentulous upper and lower jaw, which produced full removable laminar dentures on the upper and lower jaw, which used water-resistant adhesive based on polyvinylacetate and carboxymethilcellulose (cushions and/or cream "Fittydent" according to the instructions of the manufacturer, the control group consisted of 12 patients with complete edentulous upper and lower jaw, which produced full removable laminar dentures on the upper and lower jaw, in the period of adaptation to removable dentures has not applied the adhesive to improve the fixation of dentures. Microbiological examination of patients was carried out in dynamics before developing the prosthesis, after a week and after a month's stay of the prosthesis in the oral cavity. Results and discussion. Microbiological studies included determination of the qualitative and

  5. Comparison of implant-retained mandibular overdentures and conventional complete dentures : A 10-year prospective study of clinical aspects and patient satisfaction

    NARCIS (Netherlands)

    Meijer, HJA; Raghoebar, GM; Van't Hof, MA

    2003-01-01

    Purpose: The aim of this prospective randomized clinical trial was to evaluate 10 years of treatment of patients receiving a mandibular implant-retained overdenture (IRO) or a conventional complete denture (CD). Materials and Methods: One hundred twenty-one edentulous patients were treated with an

  6. Standard of disocclusion in complete dentures supported by implants without free distal ends: analysis by the finite elements method

    Directory of Open Access Journals (Sweden)

    Gustavo Diniz Greco

    2012-02-01

    Full Text Available OBJECTIVE: The occlusal patterns are key requirements for the clinical success of oral rehabilitation supported by implants. This study compared the stresses generated by the disocclusion in the canine guide occlusion (CGO and bilateral balanced occlusion (BBO on the implants and metallic infrastructure of a complete Brånemark protocol-type denture modified with the inclusion of one posterior short implant on each side. MATERIAL AND METHODS: A three-dimensional model simulated a mandible with seven titanium implants as pillars, five of them installed between the mental foramen and the two posterior implants, located at the midpoint of the occlusal surface of the first molar. A load of 15 N with an angle of 45° was applied to a tooth or distributed across three teeth to simulate the CGO or BBO, respectively. The commercial program ABAQUS® was used for the model development, before and after the processing of the data. The results were based on a linear static analysis and were used to compare the magnitude of the equivalent stress for each of the simulations. RESULTS: The results showed that the disocclusion in CGO generated higher stresses concentrated on the working side in the region of the short implant. In BBO, the stresses were less intense and more evenly distributed on the prosthesis. The maximum stress found in the simulation of the disocclusion in CGO was two times higher than that found in the simulation of the BBO. The point of maximum stress was located in the neck of the short implant on the working side. CONCLUSIONS: Under the conditions of this study, it was concluded that the BBO pattern was more suitable than CGO for the lower complete denture supported by implants without free distal ends.

  7. On denture marking.

    Science.gov (United States)

    Borrman, H I; DiZinno, J A; Wasén, J; René, N

    1999-06-01

    During the last decades in Sweden dentures have been permanently marked with a stainless steel metal band incorporated into the acrylic and containing the patient's birth date, a special number, and "S" for Sweden. The last recommendation issued by the National Board of Health and Welfare states that "the patients shall always be offered denture marking and be informed about the benefit thereof. Denture marking is not permitted if the patient refuses it". Requirements for denture markers have been that they should be biologically inert (when incorporated into the denture), not be expensive, be easy to inscribe, be possible to retrieve after an accident, and survive elevated temperatures for a reasonable time under normal circumstances. Although the frequency of edentulousness has decreased in recent years due to the improvement in oral health there remains a need to address the issue of marking of complete dentures, because there is a large variation in the oral status of populations in different countries. Given that only one marked denture can reveal the identity of a deceased person when all other methods fail to do so, makes it worthwhile. Furthermore, denture marking is important in long-term care facilities. We have investigated the issue of denture marking in Europe and in the United States. The results from the European survey show that denture marking is, to our knowledge regulated by law only in Sweden and Iceland. In the US denture marking is so far mandatory in 21 states while New York State requires dentures to be marked if the patient requests it and several other states impose the obligation to mark dentures on long-term care facilities. Since there is no international consensus regarding the issue of denture marking it is important to address it. A survey from the Nordic countries has shown that if denture marking was in general use, the contribution to the establishment of identity by forensic odontology in cases of fire would increase by about 10

  8. A comparative study of retention of complete denture base with different types of posterior palatal seals – an in vivo study

    Directory of Open Access Journals (Sweden)

    Chandu GS

    2014-11-01

    Full Text Available GS Chandu,1 BS Hema,2 Harsh Mahajan,1 Antriksh Azad,2 Ipsita Sharma,3 Anurag Azad4 1Department of Prosthodontics, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India; 2Department of Conservative Dentistry, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India; 3Department of Oral Pathology, RKDF Dental college and Research centre, Bhopal, Madhya Pradesh, India; 4Department of Oral and Maxillofacial Surgery, Bhabha College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India Aim: To evaluate retention of complete denture base with different types of posterior palatal seals. Material and methods: Ten male patients between the age group of 50 years to 60 years were selected for the study. After the primary and secondary impressions were taken, five casts were made including a cast without posterior palatal seal, a cast with single bead posterior palatal seal, a cast with double bead posterior palatal seal, a cast with butterfly shaped posterior palatal seal, and a cast with posterior palatal seal with low fusing compound by functional method. Results: It was observed that retention increased up to 108% in the posterior palatal seal with low fusing compound with functional method and the posterior palatal seal that was obtained by using functional method provided greater retention than a denture base without posterior palatal seal. Conclusion: It was concluded that the incorporation of a posterior palatal seal is important for obtaining optimum retention of the maxillary complete denture. Keywords: posterior palatal seal, denture base, complete denture, functional method

  9. A 2D panoramic surgical stent imaging: Complete arch mandibular implant fixed prosthesis along with bar supported maxillary over denture

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2017-01-01

    Full Text Available Successful rehabilitation of a patient should restore function, esthetic, and speech by prosthesis. Treatment modalities vary from patient to patient. Semi-precision attachments and implants offer several advantages over the traditional approach. The aim and objective of this report was to assess a case of a 55-year-old female patient who had lost all her teeth, except maxillary canines #13 and #23 and with severe bone loss in the mandible. Tooth-supported bar attachment was planned for maxilla, and a total of five dental implants were placed in the mandible using a flapless approach aided by radiographic gutta-percha surgical stents over panoramic two-dimensional imaging. Customized, radiographic stents help for the placement of implant in the view of paralleling and flapless surgery, completely. An immediate loading protocol is adopted as from day of the surgery to 6 weeks along with implant supported full arch fixed dentures after 4 months. The outcome of the treatment was impressive, and the patient gave a positive response with superb esthetics and functions.

  10. Stress analysis on the free-end distal extension of an implant-supported mandibular complete denture

    Directory of Open Access Journals (Sweden)

    Gustavo Diniz Greco

    2009-06-01

    Full Text Available A comparative and qualitative analysis of the tensions generated in the cantilever region of an implant-supported mandibular complete denture was conducted using the three-dimensional finite element method. The mechanical properties of the components were input in the model and a load of 15 N was applied in pre-determined points. In the first simulation, the load was applied on the occlusal surface of the first premolar. In the second simulation, it was applied on the first and second premolars. In the third simulation, it was applied on the first and second premolars and on the first molar. The different occlusion patterns produced similar tension distributions in the cantilever region, which followed a similar pattern in the three simulations. In all of the cases, the highest levels of tension were located in the region of the first implant. However, as the loads were dislocated distally, the tensions increased considerably. The more extensive the cantilever, the more compromised will be the infrastructure, the prosthetic components and the implants. Regardless of the length of the cantilever, the highest tensions will always be located in the region of the implant next to the load application point.

  11. Teach yourself visually complete WordPress

    CERN Document Server

    Majure, Janet

    2013-01-01

    Take your WordPress skills to the next level with these tips, tricks, and tasks Congratulations on getting your blog up and running with WordPress! Now are you ready to take it to the next level? Teach Yourself VISUALLY Complete WordPress takes you beyond the blogging basics with expanded tips, tricks, and techniques with clear, step-by-step instructions accompanied by screen shots. This visual book shows you how to incorporate forums, use RSS, obtain and review analytics, work with tools like Google AdSense, and much more.Shows you how to use mobile tools to edit a

  12. Teach yourself visually complete OS X Mavericks

    CERN Document Server

    McFedries, Paul

    2013-01-01

    A deep dive into OS X Mavericks If you want to quickly cover the basics of Apple's new operating system, OS X Mavericks, and then delve deeper into the topic, this is the book for you. Using clear, step-by-step screenshots, Teach Yourself VISUALLY Complete OS X Mavericks shows you how to tackle not only beginning but also intermediate and more advanced functions. Two-page, side-by-side lessons break big topics into smaller bits, and you'll find helpful sidebars with plenty of practical tips and tricks. If you're a visual learner looking for enhanced coverage of OS X Mavericks, this new guide

  13. Combined effect of new complete dentures and simple dietary advice on nutritional status in edentulous patients: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Komagamine, Yuriko; Kanazawa, Manabu; Iwaki, Maiko; Jo, Ayami; Suzuki, Hiroyuki; Amagai, Noriko; Minakuchi, Shunsuke

    2016-11-09

    Individuals who are edentulous have a lower intake of fruit, vegetables, fiber, and protein compared with their dentate counterparts because tooth loss is accompanied by a decrease in ability to chew. Whether or not a combination of prosthetic rehabilitation and simple dietary advice produces improvement in dietary intake among edentulous persons is unclear. We aim to investigate the effect of a simultaneous combination of simple dietary advice delivered by dentists and provision of new complete dentures on dietary intake in edentulous individuals who request new dentures. Through a double-blinded, parallel, randomized controlled trial in which 70 edentate persons who request new complete dentures will be enrolled, eligible study participants will be randomly allocated to either a dietary intervention group receiving dietary advice or to a control group receiving only advice on the care and maintenance of dentures. Outcome measures include daily intake of nutrients and food items, assessed using a brief self-administered diet history questionnaire; antioxidant capacity, determined using blood and urine samples; nutritional status, assessed with the Mini-Nutritional Assessment-Short Form; oral health-related quality of life, assessed with the Japanese version of the Oral Health Impact Profile-EDENT and the Geriatric Oral Health Assessment Index; subjective chewing ability; masticatory performance, assessed using a color-changeable chewing gum and a gummy jelly; patient self-assessment of dentures; mild cognitive impairment, assessed with the Japanese version of the Montreal Cognitive Assessment; and functional capacity, assessed with the Japan Science and Technology Agency Index of Competence. Outcome measures, except for antioxidant capacity, are to be implemented at three time points: at baseline and at 3 and 6 months following intervention. Antioxidant capacity data are to be collected twice: at baseline and at 3 months following intervention. Differences

  14. Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers

    Directory of Open Access Journals (Sweden)

    Yuri Martins COSTA

    2015-12-01

    Full Text Available ABSTRACT Low pressure Pain Threshold (PPT is considered a risk factor for Temporomandibular Disorders (TMD and is influenced by psychological variables. Objectives To correlate deep pain sensitivity of masticatory muscles with prosthetic factors and Oral-Health-Related Quality of Life (OHRQoL in completely edentulous subjects. Material and Methods A total of 29 complete denture wearers were recruited. The variables were: a Pressure Pain Threshold (PPT of the masseter and temporalis; b retention, stability, and tooth wear of dentures; c Vertical Dimension of Occlusion (VDO; d Oral Health Impact Profile (OHIP adapted to orofacial pain. The Kolmogorov-Smirnov test, the Pearson Product-Moment correlation coefficient, the Spearman Rank correlation coefficient, the Point-Biserial correlation coefficient, and the Bonferroni correction (α=1% were applied to the data. Results The mean age (standard deviation of the participants was of 70.1 years (9.5 and 82% of them were females. There were no significant correlations with prosthetic factors, but significant negative correlations were found between the OHIP and the PPT of the anterior temporalis (r=-0.50, 95% CI-0.73 to 0.17, p=0.005. Discussion The deep pain sensitivity of masticatory muscles in complete dentures wearers is associated with OHRQoL, but not with prosthetic factors.

  15. Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers

    Science.gov (United States)

    COSTA, Yuri Martins; PORPORATTI, André Luís; HILGENBERG-SYDNEY, Priscila Brenner; BONJARDIM, Leonardo Rigoldi; CONTI, Paulo César Rodrigues

    2015-01-01

    ABSTRACT Low pressure Pain Threshold (PPT) is considered a risk factor for Temporomandibular Disorders (TMD) and is influenced by psychological variables. Objectives To correlate deep pain sensitivity of masticatory muscles with prosthetic factors and Oral-Health-Related Quality of Life (OHRQoL) in completely edentulous subjects. Material and Methods A total of 29 complete denture wearers were recruited. The variables were: a) Pressure Pain Threshold (PPT) of the masseter and temporalis; b) retention, stability, and tooth wear of dentures; c) Vertical Dimension of Occlusion (VDO); d) Oral Health Impact Profile (OHIP) adapted to orofacial pain. The Kolmogorov-Smirnov test, the Pearson Product-Moment correlation coefficient, the Spearman Rank correlation coefficient, the Point-Biserial correlation coefficient, and the Bonferroni correction (α=1%) were applied to the data. Results The mean age (standard deviation) of the participants was of 70.1 years (9.5) and 82% of them were females. There were no significant correlations with prosthetic factors, but significant negative correlations were found between the OHIP and the PPT of the anterior temporalis (r=-0.50, 95% CI-0.73 to 0.17, p=0.005). Discussion The deep pain sensitivity of masticatory muscles in complete dentures wearers is associated with OHRQoL, but not with prosthetic factors. PMID:26814457

  16. A clinical study to evaluate denture adhesive use in well-fitting dentures.

    Science.gov (United States)

    Munoz, Carlos A; Gendreau, Linda; Shanga, Gilbert; Magnuszewski, Tabetha; Fernandez, Patricia; Durocher, John

    2012-02-01

    The objective of this study was the assessment of retention and stability and functional benefits of denture adhesive applied to well-fitting and well-made dentures. This was a randomized, crossover study to compare two marketed denture adhesives (test cream, Super Poligrip® Free, and test strip, Super Poligrip® Comfort Seal Strips) and an unmarketed cream adhesive (GlaxoSmith Kline Consumer Healthcare) with no adhesive as the negative control. Thirty-six subjects completed the study. One hour after the application of denture adhesive, retention and stability were measured using the Kapur Index and maxillary incisal bite force. Two hours after application, functional tests were used to assess denture movement and peanut particle migration under the denture. Subjects also rated confidence, comfort, satisfaction with dentures, and denture wobble in conjunction with the functional tests. Denture adhesives significantly (p dentures. Subjects experienced significantly (p dentures. Significant (p denture wobble were associated with the use of adhesive. There was significant (p denture adhesive was well tolerated. The results of this study provide evidence that use of Super Poligrip® denture adhesives can enhance aspects of performance of complete well-fitting dentures as well as provide increased comfort, confidence, and satisfaction with dentures. © 2011 by the American College of Prosthodontists.

  17. Epidemiology and etiology of denture stomatitis.

    Science.gov (United States)

    Gendreau, Linda; Loewy, Zvi G

    2011-06-01

    Denture stomatitis, a common disorder affecting denture wearers, is characterized as inflammation and erythema of the oral mucosal areas covered by the denture. Despite its commonality, the etiology of denture stomatitis is not completely understood. A search of the literature was conducted in the PubMed electronic database (through November 2009) to identify relevant articles for inclusion in a review updating information on the epidemiology and etiology of denture stomatitis and the potential role of denture materials in this disorder. Epidemiological studies report prevalence of denture stomatitis among denture wearers to range from 15% to over 70%. Studies have been conducted among various population samples, and this appears to influence prevalence rates. In general, where reported, incidence of denture stomatitis is higher among elderly denture users and among women. Etiological factors include poor denture hygiene, continual and nighttime wearing of removable dentures, accumulation of denture plaque, and bacterial and yeast contamination of denture surface. In addition, poor-fitting dentures can increase mucosal trauma. All of these factors appear to increase the ability of Candida albicans to colonize both the denture and oral mucosal surfaces, where it acts as an opportunistic pathogen. Antifungal treatment can eradicate C. albicans contamination and relieve stomatitis symptoms, but unless dentures are decontaminated and their cleanliness maintained, stomatitis will recur when antifungal therapy is discontinued. New developments related to denture materials are focusing on means to reduce development of adherent biofilms. These may have value in reducing bacterial and yeast colonization, and could lead to reductions in denture stomatitis with appropriate denture hygiene.

  18. Electromyographic analysis of the upper and lower fascicles of the orbicular oris muscle, in edentulous patients, before and after complete denture implantation.

    Science.gov (United States)

    Santos, C Moreto; Vitti, M; de Mattos, M da Glória Chiarelo; Semprini, M; Paranhos, H de Freitas Oliveira; Regalo, S Cecilio Hallak

    2003-01-01

    The orbicular oris muscle, including its upper and lower fascicles, the alveolar processes and dental arches, constitute a complex morpho-functional system, located in the lower third of the face, which is very important for the clinical determination of the occlusal vertical dimension. Any alteration of this system, as in the case of edentulous patients, might produce esthetic problems and alterations in the muscular tonicity. This study was aimed to evaluate the electromyographic behaviour of that musculature in patients while pronouncing the syllables PAH, BAH, MAH, SAH, FAH, VAH, MEE, and the word MISSISSIPPI. Edentulous patients were submitted to electromyographic tests under two clinical conditions: before and after the implantation of complete dentures. A K6-I EMG Light Channel Surface Electromyograph was utilized (Myo-tronics Co. Seattle, WA, USA). The Analysis of Variance, with 3 sources of variation (Syllables, Muscles and Clinical Conditions) and 12 repetitions, indicated statistically significant differences in the pronunciation of the different syllables. For the Muscles factor, the analysis revealed higher electromyographic readings in the lower fascicle of the orbicular oris muscle, as compared with those of the upper fascicle. The comparison among the Clinical Conditions indicated higher electromyographic values for the edentulous condition (i.e., before complete denture implantation), as compared to those recorded after denture implantation.

  19. Geriatric slim implants for complete denture wearers: clinical aspects and perspectives

    OpenAIRE

    Huard C; Bessadet M; Nicolas E; Veyrune JL

    2013-01-01

    Cedric Huard,2 Marion Bessadet,1,2 Emmanuel Nicolas,1,2 Jean-Luc Veyrune,1,21Clermont Université, Université d'Auvergne, Centre de Recherche en Odontologie Clinique, Clermont-Ferrand, France; 2CHU Clermont-Ferrand, Service d'Odontologie, Clermont-Ferrand, FranceBackground: Advances made in prevention have helped postpone complete edentulism in older patients. However, in the elderly, the physiological state reduces patients' ability to adapt to or...

  20. Clinical and histopathological changes in palatal mucosa following two treatment modalities in patients wearing maxillary complete dentures with suction cup

    Directory of Open Access Journals (Sweden)

    Yogesh Rao

    2014-01-01

    Full Text Available Aim: The aim of the study was to determine the clinical and histopathological effect on palatal hyperplasia caused by suction cups by different methods of management used for recovery of abused tissues. Materials and Methods: A total of 35 subjects agreed for biopsy procedure, from 50 patients who gave consent for the study. Out of the 35 subjects, 20 were randomly selected for treatment with discontinuation of denture (Group I and 15 selected for denture relined with tissue conditioner (COE-comfort (Group II. Punch biopsy procedure was performed on these patients to study the histopathology of the lesion before the two modalities of treatment was administered on them. Results: Inflammation caused by suction cup decreased considerably by both the treatment modalities, i.e., the use of tissue conditioner as well as discontinuation of denture (tissue rest for a period of 2 weeks. Conclusion: It was concluded that wearing denture day and night considerably increased the severity of inflammatory papillary hyperplasia of palate. Healing was better with tissue conditioner when compared with tissue rest.

  1. Effect of head posture on tooth contacts in dentate and complete denture wearers using computerized occlusal analysis system

    Directory of Open Access Journals (Sweden)

    Swati Gupta

    2017-01-01

    Conclusion: It was concluded that the occlusal contacts vary at different head posture in dentate as well as in denture wearers. With ventroflexion, the number of tooth contact decreased as compared to upright-erect position in both groups. Clinical implication - since the number of tooth contacts varies with varying head postures, it is recommended that the balancing of the contacts should be done at varying head postures.

  2. Denture stomatitis.

    Science.gov (United States)

    Chen, Amy Yuntzu-Yen; Zirwas, Matthew J

    2007-01-01

    A 70-year-old woman presented for evaluation of an eruption localized to the area covered by her partial upper denture. Her medical history and physical examination were otherwise unremarkable. She originally had a metal upper partial denture, which she used for many years without difficulty. Four years before presentation, she developed a painful eruption affecting only the tissue covered by the upper partial denture. Contact dermatitis to metal was suspected, and a new upper partial denture constructed primarily of acrylates was fashioned. When she transitioned to the new denture, the inflammation in her oral mucosa persisted and perhaps worsened, despite an excellent fit. Examination revealed striking erythema and mild edema sharply localized to the areas where the partial upper denture contacted the gum ridge. Patch testing was performed and revealed allergies to multiple acrylates, including methyl methacrylate. A swab from the gums was sent for yeast culture. No Candida was detected. Based on suspected candidal overgrowth on the denture, the patient was advised to begin applying nystatin ointment between the gums and the denture, and to start soaking the dentures nightly in chlorhexidine 0.12% solution. In addition, because the relevance of the acrylate allergy was unclear, her dentist was contacted and it was recommended that the dentures be boiled to induce polymerization of any residual un-reacted methacrylate monomers. The patient had a 90% improvement in the clinical appearance and in symptoms at an 8-week follow-up appointment. Due to logistic issues, the dentures had not yet been boiled. The improvement, despite the dentures not having been boiled, was felt to demonstrate that the acrylate allergy was not relevant. The patient has continued to slowly show further improvement over 6 months of follow-up.

  3. An international multicenter study on the effectiveness of a denture adhesive in maxillary dentures using disposable gnathometers

    NARCIS (Netherlands)

    de Baat, Cees; van 't Hof, Martin; van Zeghbroeck, Lieve; Ozcan, Mutlu; Kalk, Warner

    No consensus has been achieved on whether denture adhesives are beneficial adjuncts in denture-wearers management. The purpose of this international multicenter study was to determine objectively the effect of a denture adhesive (Kukident) on the retention of complete maxillary dentures using

  4. An international multicenter study on the effectiveness of a denture adhesive in maxillary dentures using disposable gnathometers.

    NARCIS (Netherlands)

    Baat, C. de; Hof, M.A. van 't; Zeghbroeck, L. van; Ozcan, M.; Kalk, W.

    2007-01-01

    No consensus has been achieved on whether denture adhesives are beneficial adjuncts in denture-wearers management. The purpose of this international multicenter study was to determine objectively the effect of a denture adhesive (Kukident) on the retention of complete maxillary dentures using

  5. The clinical effects of complete denture with reducing vertical dimensions in the aged patients%降低垂直距离在老年全口义齿修复中的应用

    Institute of Scientific and Technical Information of China (English)

    祁兵; 罗卫; 张景林

    2012-01-01

    PURPOSE: To investigate the clinical effects of complete denture with additional 3mm reduction of vertical dimensions in the aged patients. METHODS: Forty edentulous patients with severe resorption of residual ridge were treated with two kinds of complete dentures, i.e. traditional complete denture (TCD) and special complete denture with additional 3mm reduction nf vertical dimensions (SOD) After three moulds of wearing, the masticatory efficiency of dentures were measured by color-metric analysis and the incidences of sore spot was assessed by SAS 6.04 software package. RESULTS:there was no significant difference between TCD and SCO lor the masticatory efficiency(P>0.05). Bui the number of sore spots in SCD was significantly less than that in TCD (P<0.05). CONCLUSION: Complete denture with additional 3mm reduction of vertical dimensions is feasible for clinical practice in the aged patients.%目的:观察适当降低垂直距离对老年人全口义齿修复效果的影响.方法:采用传统法和降低3mm垂直距离法,为40例老年患者分别制作完成2副全口义齿.适应3个月后,测定咀嚼效能和压痛点.采用SAS6.04软件包对数据进行统计学分析.结果:降低3mm垂直距离制作的全口义齿咀嚼效能与传统法比较,无显著差异(P>005),但压痛点显著少于传统法(P<0.05).结论:降低3mm垂直距离法是临床上可行的老年人全口义齿修复方法.

  6. Digital immediate dentures treatment: A clinical report of two patients.

    Science.gov (United States)

    Neumeier, Toni Tien; Neumeier, Harold

    2016-09-01

    The use of computer-aided engineering (CAE) and computer-aided design and computer-aided manufacturing (CAD-CAM) technology to fabricate complete dentures was introduced in 2011. Clinical procedures for digital immediate dentures can be identical to those for conventional immediate dentures and can be simplified by leaving all remaining dentition until the time of extraction and denture placement. Through the digital process, a single digital design and a definitive digital record are created which can be used to fabricate the immediate digital denture and surgical reduction guide for alveoloplasty. Digital immediate dentures can be relined using the same process as for conventional dentures. The definitive digital dentures can be fabricated with a reline impression and new centric relation record, using the existing digital immediate denture without additional clinical procedures. Providing patients with digital immediate dentures is a viable trend.

  7. Application of Boxing Perfusion Technique in Complete Denture%围模灌注技术在全口义齿修复中的应用

    Institute of Scientific and Technical Information of China (English)

    尹雪

    2014-01-01

    On the process of making complete denture in the edentulous impression, obtain good accurately is the key to the success of the complete dentures, and correct perioperative mode operation is a prerequisite to obtain accurate impression. For beginners, recommend the use of red wax, this wil ensure that the final impression edge enough exposure. Model perfusion hardened demolding, should pay at ention to first with water bath heating, softening in the undercut area border molding paste impression material, avoid forced demoulding by gypsum terminal damage model. The final model after polishing after forming, the model bot om should produce V like reset slot, the purpose is to prepare for the fol ow-up of two upper complete denture after forming laboratory, reset slot can guarantee two accurate reset to frame gypsum base end model.%在制作全口义齿的过程中,获得良好精确的无牙颌印模是全口义齿修复成功的关键,而正确的围模操作是取得精确印模的前提。对于初学者,建议使用红蜡片法,这样可以确保终印模边缘显露充分。模型灌注硬固后进行脱模时,应该注意先用水浴加热,软化位于倒凹区的边缘整塑膏等印模材料,避免强行脱模引起的石膏终模型损伤。终模型经打磨成形后,在其模型底面应制作V状复位槽,其目的是为后续全口义齿基托成型后进行技工室二次上架做好准备,复位槽能够保证终模型二次准确复位至架石膏底座上。

  8. Influence of modified tray on mandible complete denture impression%改良型托盘对下颌全口义齿印模的影响

    Institute of Scientific and Technical Information of China (English)

    崔荣智; 潘新华

    2012-01-01

    Objective:To observe the influence of modified tray and conventional tray on mandible complete denture and the clinical effect after dental restoration. Method: 60 cases that were edentulous in mandible or with inferior alveolar ridge were treated with two methods of mandible complet denture impression five items were evaluated after wearing den- ference in the two groups in the aspects of comfort and masticatory function, mucosa and food impact ion, with P >0.05; while in the aspects of retaining function,the group with modified tray was superior to the group with conventional tray, with P < 0.05. Conclusion: Impression with modified tray obviously increased the absorption force of mandible complete denture, and may be applicable generally to the patients with inferior alveolar ridge%目的:观察改良型托盘与传统托盘对下颌全口义齿印模的影响,比较义齿修复后的临床效果.方法:对60例无牙颌牙槽嵴条件较差病例进行两种印模方法制取下颌全口义齿印模,义齿戴入后对义齿的固位功能、黏膜情况,舒适性、咀嚼功能、食物嵌塞5项内容进行评价.结果:两组病例在舒适程度、黏膜情况、食物嵌塞、咀嚼功能等方面无显著性差异,P >0.05;但在固位功能方面改良型托盘组明显优于传统托盘组,P <0.05.结论:改良型托盘制取的印模显著提高了下颌全口义齿的吸附力,可以普遍应用于牙槽嵴或黏膜条件差的无牙颌修复患者.

  9. Denture hygiene knowledge and practice amongst patients in a ...

    African Journals Online (AJOL)

    Log in or Register to get access to full text downloads. ... Methods: This was a cross-sectional study involving 203 patients attending a teaching hospital. ... Other information obtained were the duration of denture use, frequency of denture cleaning and type of ... About 41.9% had been using dentures for more than 10 years.

  10. Algebra a complete introduction : teach yourself

    CERN Document Server

    Neill, Hugh

    2013-01-01

    Algebra: A Complete Introduction is the most comprehensive yet easy-to-use introduction to using Algebra. Written by a leading expert, this book will help you if you are studying for an important exam or essay, or if you simply want to improve your knowledge. The book covers all the key areas of algebra including elementary operations, linear equations, formulae, simultaneous equations, quadratic equations, logarithms, variation, laws and sequences. Everything you will need is here in this one book. Each chapter includes not only an explanation of the knowledge and skills you need, but also worked examples and test questions.

  11. Mathematics a complete introduction : teach yourself

    CERN Document Server

    Neill, Hugh

    2013-01-01

    Maths does not have to be difficult. This book, complete with exercises and answers, forms a course which will take you from beginner or intermediate level to being a confident mathematician. This book includes simple step-by-step explanations, to help you grasp new topics or those that have previously confused you; practice questions throughout, to help you embed your learning and improve your confidence; End of chapter summaries, to help you remember the key points you''ve learned; All in one great-value book, so you don''t need any separate workbooks or coursebooks.

  12. Calculus a complete introduction : teach yourself

    CERN Document Server

    Neill, Hugh

    2013-01-01

    Calculus: A Complete Introduction is the most comprehensive yet easy-to-use introduction to using calculus. Written by a leading expert, this book will help you if you are studying for an important exam or essay, or if you simply want to improve your knowledge. The book covers all areas of calculus, including functions, gradients, rates of change, differentiation, exponential and logarithmic functions and integration. Everything you will need to know is here in one book. Each chapter includes not only an explanation of the knowledge and skills you need, but also worked examples and test questions.

  13. Trigonometry a complete introduction : teach yourself

    CERN Document Server

    Neill, Hugh

    2013-01-01

    Trigonometry: A Complete Introduction is the most comprehensive yet easy-to-use introduction to Trigonometry. Written by a leading expert, this book will help you if you are studying for an important exam or essay, or if you simply want to improve your knowledge. The book covers all areas of trigonometry including the theory and equations of tangent, sine and cosine, using trigonometry in three dimensions and for angles of any magnitude, and applications of trigonometry including radians, ratio, compound angles and circles related to triangles. Everything you will need is here in this one book. Each chapter includes not only an explanation of the knowledge and skills you need, but also worked examples and test questions.

  14. Analysis of stress on mucosa and basal bone underlying complete dentures with different reliner material thicknesses: a three-dimensional finite element study.

    Science.gov (United States)

    Lima, J B G; Orsi, I A; Borie, E; Lima, J H F; Noritomi, P Y

    2013-10-01

    The aim of this study was to determine the optimal thickness of reliner material that provides the least amount of stress on thin mucosa and supporting bone in patients with complete removable dentures using a three-dimensional finite element analyses. The model was obtained from two CT scans of edentulous mandibles with dentures supported by the alveolar ridge. After virtual reconstruction, the three-dimensional models were exported to the solidworks cad software and divided into six groups based on the thickness of the reliner material as follows: (i) without material, (ii) 0·5 mm, (iii) 1 mm, (iv) 1·5 mm, (v) 2 mm and (vi) 2·5 mm. The applied load was 60 N and perpendicular to the long axis of the alveolar ridge of all the prosthetic teeth, and the mucosal thickness used was 1 mm. The analyses were based on the maximum principal stress in the fibromucosa and the minimum principal stress in the basal bone. Stress concentration was observed in the anterior zone of the mandible in the mucosa and in the bone. The maximum and minimum principal stress in the mucosa and bone, respectively, decreased, whereas the thickness of the reliner material increased until 2 mm, which transmitted the lowest stress, compared with the control. Reliner materials with a thickness of 2·5 mm showed higher stress values than those with a thickness of 2 mm. In conclusion, reliner material with a thickness of 2 mm transmitted the lowest amount of stress to the mucosa and bone in 1 mm of mucosa thickness.

  15. PATIENT SATISFACTION AND CHEWING ABILITY WITH IMPLANT-RETAINED MANDIBULAR OVERDENTURES - A COMPARISON WITH NEW COMPLETE DENTURES WITH OR WITHOUT PREPROSTHETIC SURGERY

    NARCIS (Netherlands)

    BOERRIGTER, EM; STEGENGA, B; RAGHOEBAR, GM; BOERING, G

    1995-01-01

    Purpose: The objective of this study was to compare denture satisfaction and chewing ability of edentulous patients treated with dental implant-retained overdentures or with full dentures with or without previous preprosthetic surgery. Patients and Methods: This study was a controlled clinical

  16. PATIENT SATISFACTION WITH IMPLANT-RETAINED MANDIBULAR OVERDENTURES - A COMPARISON WITH NEW COMPLETE DENTURES NOT RETAINED BY IMPLANTS - A MULTICENTER RANDOMIZED CLINICAL-TRIAL

    NARCIS (Netherlands)

    BOERRIGTER, EM; GEERTMAN, ME; VANOORT, RP; BOUMA, J; RAGHOEBAR, GM; VANWAAS, MAJ; VANTHOF, MA; BOERING, G; KALK, W

    1995-01-01

    Objectives-The aim of this study was to establish the treatment outcome of full denture treatment with or without implant support, in which the outcome assessment focuses on the patient's subjective evaluation ('denture-satisfaction'). Design-A multicenter randomized clinical trial,

  17. PATIENT SATISFACTION AND CHEWING ABILITY WITH IMPLANT-RETAINED MANDIBULAR OVERDENTURES - A COMPARISON WITH NEW COMPLETE DENTURES WITH OR WITHOUT PREPROSTHETIC SURGERY

    NARCIS (Netherlands)

    BOERRIGTER, EM; STEGENGA, B; RAGHOEBAR, GM; BOERING, G

    1995-01-01

    Purpose: The objective of this study was to compare denture satisfaction and chewing ability of edentulous patients treated with dental implant-retained overdentures or with full dentures with or without previous preprosthetic surgery. Patients and Methods: This study was a controlled clinical trial

  18. A blended learning approach to teaching pre-clinical complete denture prosthodontics.

    Science.gov (United States)

    Faraone, K L; Garrett, P H; Romberg, E

    2013-02-01

    The current study tested the hypothesis that a blended learning curriculum would develop competency in both pre-clinical laboratory and didactic learning with less direct supervision than in a traditional curriculum, and be positively accepted by both the students and the faculty. With the ability to efficiently deliver course material electronically came the ability to blend the traditional delivery of course material with an asynchronous approach involving online lecture presentations and online laboratory demonstrations. The class was divided into two groups with bench space available to accommodate self-paced learning. All audio-visual and written support materials for both didactic and laboratory procedures were provided to the students at the beginning of the semester on a DVD. These materials included online access through the Blackboard Learning System™. Students' performance and satisfaction in the course as well as the supporting faculty response to the course were very favourable to the new blended curriculum. Making use of the technologically advanced environment, the blended curriculum fostered student-focused learning to develop the didactic and laboratory skills necessary for competency in a pre-clinical setting. © 2012 John Wiley & Sons A/S.

  19. Introduction on the progress of impression techniques of complete denture%全口义齿印模技术的进展介绍

    Institute of Scientific and Technical Information of China (English)

    孙惠强; 刘金

    2013-01-01

    Taking impressions is the first step and the key to complete denture fabrication. An accurate impression of edentulous jaws must precisely reflect the anatomical shape and movement of the residual ridge and adjacent oral structures. Accurately increasing the border seal, retention, and comfort of the complete denture, as well as maintaining its stability during oral functional movements, is important. Numerous studies have shown that traditional impression methods are unable to meet the clinical requirements. Various modified impression methods, such as window tray, dynamic functional impression, frame cut back tray, and neutral zone techniques, etc., have continuously emerged in recent years. In the author’s opinion, the most suitable technique for taking impressions should be chosen based on the different residual alveolar ridge shapes, general conditions, or oral rehabilitation demands. This article reviews the various complete denture impression techniques and focuses on their corresponding technical key points and clinical applications.%采取印模是制作全口义齿的第一步,是成功修复全口义齿的关键。准确的全口印模要精确地反映无牙颌患者剩余牙槽嵴的解剖形态和周围组织生理功能活动范围,以便使义齿基托与口腔黏膜高度密合,获得良好的边缘封闭,从而取得全口义齿良好的固位,并能在功能运动时保持稳定。越来越多的研究表明,传统的印模方法已不能满足临床要求。近年来各种改良式印模方法层出不穷,如:开窗托盘印模法、动态压力式印模法、后缘截断框架式托盘印模法及中性区技术等,这些方法在取组织面、磨光面或黏膜转折处的印模上各有优势或侧重。针对不同的患者,应根据其剩余牙槽嵴条件、全身情况或修复需求等情况而选择相应的印模方法。本文就无牙颌取模技术的不同侧重角度、技术要点、适应证等方面作一综述。

  20. Transition of natural teeth to denture (Literature review

    Directory of Open Access Journals (Sweden)

    Catarina Anita Kristanti

    2016-06-01

    Full Text Available The aesthetic needs of patients with complete dentures is currently greatly increasing. To encounter of the stages and the process of complete dentures settlement that takes time, the operators must develop a variety of techniques to overcome them. One of it is by considering the transitional denture method to overcome the aesthetics problem during these stages. Various selection methods during this transitional stage are the making of overdenture, immediate dentures or denture after clearance all remaining natural teeth. Each one has its advantages and disadvantages. Principally, the aesthetic needs, adaptation process, masticatory function and the tissues health are the main reason of this transitional denture. As conclusion, dentures transition method is very helpfull to encounter the patients problems to finish the process of definitive dentures settlement.

  1. Current techniques in CAD/CAM denture fabrication.

    Science.gov (United States)

    Baba, Nadim Z; AlRumaih, Hamad S; Goodacre, Brian J; Goodacre, Charles J

    2016-01-01

    Recently, the use of computer-aided design/computer-aided manufacturing (CAD/CAM) to produce complete dentures has seen exponential growth in the dental market, and the number of commercially available CAD/CAM denture systems grows every year. The purpose of this article is to describe the clinical and laboratory procedures of 5 CAD/CAM denture systems.

  2. 医患沟通对全口义齿修复满意率的影响%The effect of doctor-patient communication on complete denture restoration

    Institute of Scientific and Technical Information of China (English)

    王万伟; 韦玉舫; 李军; 张婷婷

    2013-01-01

      目的评估医患沟通对全口义齿临床修复效果的影响.方法选择初次就诊行全口义齿修复的患者270例,分为试验组和对照组,试验组给予充分的医患沟通,对照组按照正常操作流程进行常规修复,在修复佩戴全口义齿2月后统计分析患者对修复体的满意率.结果所有患者对全口义齿修复的总满意率84.44%,试验组的满意率为89.24%,对照组的为77.68%,两组差异有统计学意义(P<0.001).结论进行良好的医患沟通能够提高全口义齿修复的满意度,缩短适应时间.%Objective To assess the effect of doctor-patient communication on complete denture restoration. Methods Two hundred and seventy patients of complete denture restoration were randomly divided into the experimental group and control group. The experimental group was given an effective communication; the control group was for regular repair. Two months after repairing, the satisfaction of restoration was statistical analyzed. Results The all satisfaction rate of complete denture restoration was 84.44%, the experimental group was up to 89.24%, the control group reached 77.68%. The differences between two groups were statistical significantly(P<0.001). Conclusion Effective doctor-patient communication can improve the satisfaction of complete denture restoration, short the adaptation time.

  3. Correlation between Patients' Satisfaction with Complete Dentures and Their Self-assessment of Masticatory Function%全口义齿满意度和咀嚼能力自我评价的相关性研究

    Institute of Scientific and Technical Information of China (English)

    何克飞; 张玉峰; 陈小晖

    2012-01-01

    Objective: To study the correlation between patients' satisfaction with complete dentures and their self -assessment for masticatory function. Methods: A questionnaire on the satisfaction and food intaking in complete denture wearers was performed through telephone recall. Results: The satisfaction is highly correlated with the self - assessment of masticatory function. Conclusion: The masticatory score acquired from the food intaking questionnaire presents high correlation with the satisfaction of complete denture and is capable to reflect the wearers' actual masticatory function.%目的:问卷调查全口义齿满意度与主观咀嚼能力的相关性.方法:通过电话回访的形式进行全口义齿满意度和咀嚼食物类型的问卷调查.结果:全口义齿患者的满意度与咀嚼能力自我评价高度相关.结论:食物问卷调查表分析获得的咀嚼能力分值与全口义齿满意度具有高度相关性,能够反应患者的实际咀嚼功能,是研究全口义齿患者咀嚼功能的现实可靠的方法.

  4. Complete electronics self-teaching guide with projects

    CERN Document Server

    Boysen, Earl

    2012-01-01

    An all-in-one resource on everything electronics-related! For almost 30 years, this book has been a classic text for electronics enthusiasts. Now completely updated for today's technology, this latest version combines concepts, self-tests, and hands-on projects to offer you a completely repackaged and revised resource. This unique self-teaching guide features easy-to-understand explanations that are presented in a user-friendly format to help you learn the essentials you need to work with electronic circuits. All you need is a general understanding of electronics concepts such as Oh

  5. Level of Denture Cleanliness Influences the Presence of Denture Stomatitis on Maxillary Denture Bearing-Mucosa

    OpenAIRE

    Winatty Krisma; Martha Mozartha; Rani Purba

    2014-01-01

    Plaque accumulation on internal surface of denture is a common problem among removable denture wearers. Poor denture cleanliness can increase colonization of Candida albicans and cause inflammatory reaction of denture-bearing mucosa, i.e. denture stomatitis. Objective: To find out the effect of denture cleanliness level on denture stomatitis on maxillary denture-bearing mucosa in a group of removable denture wearers who received prosthodontic treatment at Poliklinik Gigi RSMH Palembang and to...

  6. The effect of different prosthetic restorations on the dietary selection in edentulous patients. A longitudinal study of patients initially treated with optimal complete dentures and finally with tissue-integrated prostheses.

    Science.gov (United States)

    Sandström, B; Lindquist, L W

    1987-12-01

    The effect of prosthetic restoration of masticatory ability on dietary selection was evaluated in 23 edentulous patients with denture adaptation problems. The patients were first given optimal complete dentures and then a fixed prosthesis on tissue-integrated implants in the lower jaw. Changes in dietary selection were evaluated from 4-day records obtained before prosthetic treatment and on six occasions up to 78 months after treatment. With the method used, no significant changes in food selection were recorded during the rehabilitation period, except for a slight increase in intake of crisp bread and fresh fruit after treatment with fixed tissue-integrated prostheses in the mandibular jaw. It is concluded that an improved oral function will not in itself lead to a change in dietary selection and that dietary changes probably require professional and individually given dietary advice by a trained dietitian.

  7. Level of Denture Cleanliness Influences the Presence of Denture Stomatitis on Maxillary Denture Bearing-Mucosa

    Directory of Open Access Journals (Sweden)

    Winatty Krisma

    2014-12-01

    Full Text Available Plaque accumulation on internal surface of denture is a common problem among removable denture wearers. Poor denture cleanliness can increase colonization of Candida albicans and cause inflammatory reaction of denture-bearing mucosa, i.e. denture stomatitis. Objective: To find out the effect of denture cleanliness level on denture stomatitis on maxillary denture-bearing mucosa in a group of removable denture wearers who received prosthodontic treatment at Poliklinik Gigi RSMH Palembang and to investigate the denture hygiene habits of removable denture wearers. Methods: Thirty subjects participated in this study. Denture cleanliness level was assessed with disclosing solution to disclose denture plaque on internal surface of maxillary denture. Cleanliness level was graded according to Budtz-Jorgensen. Intraoral examination was done to determine any visible signs of denture stomatitis. Data referring to denture hygiene habits of removable denture wearers was collected from interview using questionnaire. Data were analyzed using the Komolgorov-Smirnov test. Results: Result of the study showed that 40% subjects had poor upper denture cleanliness. Denture stomatitis was observed on maxillary denture-bearing mucosa in 43.3% subjects. Kolmogorov-Smirnov test showed that there was a significant effect of denture cleanliness level on denture stomatitis on maxillary denture-bearing mucosa (p<0.05. Conclusion: Denture cleanliness level influence the occurence of denture stomatitis on maxillary denture bearing-mucosa in a group of removable denture wearers who received prosthodontic treatment.

  8. Investigating Frequency of Temporo- Mandibular Dysfunctions in Complete Denture Wearers Referring to the Prosthesis Department of Dental School during 2013-2014

    Directory of Open Access Journals (Sweden)

    MH Lotfikamran

    2016-04-01

    Results: 46 patients (46% were male, 54 patients (54% were female, and the age range was 35-64 years. The range of using denture was 1-3 years and the mean duration of using denture was 2.52 ± 1.58 years. The most common age range for the relevant disorders was 40-50 years and the frequency of TMD was more in women than in men. Moreover, there was a significant relationship between age factor and Anamnestic index (P=0.037, whereas no significant relationship was observed between frequency of these disorders, level of education and also duration of using previous denture. Conclusion: The study findings revealed that it seems that with increasing age the rate of complaints from TMD problems increases.

  9. Influence of spark erosion on the fit of screw-retained Co-Cr fixed complete denture frameworks veneered with different materials.

    Science.gov (United States)

    Presotto, Anna Gabriella Camacho; Oliveira, Luciana Valadares; Pisani, Marina Xavier; Barão, Valentim Adelino Ricardo; Mesquita, Marcelo Ferraz

    2017-09-29

    Spark erosion is a fit corrective technology that can be used even after the veneering material has been applied. The framework does not require sectioning, thus preserving its mechanical resistance. However, the spark erosion effect on veneered Co-Cr fixed complete denture (FCD) frameworks has not been investigated. The purpose of this in vitro study was to evaluate whether spark erosion is effective in improving marginal fit on screw-retained Co-Cr FCD frameworks veneered with different materials. A comparison between ceramic applications and simulated ceramic firing cycles was also investigated. Forty FCD frameworks were fabricated with a Co-Cr alloy. Four groups (n=10) were obtained according to the veneer material used on frameworks: HR (heat-polymerized resin); LR (light-polymerized resin); C (ceramic); and SC (simulated ceramic firing cycle). The spark erosion process was conducted for all groups. The marginal fit was analyzed according to the single-screw test protocol, and the measurements were performed at 3 evaluation times: initial, after veneer material application, and after spark erosion process. The results were submitted to a 2-way repeated measures ANOVA and the Tukey honest significant differences test (α=.05). Poorer marginal fit (in micrometers) was noted after veneer material application, where the HR and C groups presented the worst values (HR: 170; LR: 72; C: 165; SC: 86; Perosion process was effective in improving the fit for all groups (HR: 109; LR: 52; C: 110; SC: 60; Perosion improved the fit of Co-Cr FCD frameworks veneered with different materials. An actual ceramic application should be used to assess distortions generated by veneer material application instead of using only simulated ceramic firing cycles. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Dimensional stability of distances between posterior teeth in maxillary complete dentures Estabilidade dimensional de distâncias entre dentes posteriores em prótese total superior

    Directory of Open Access Journals (Sweden)

    Rafael Leonardo Xediek Consani

    2006-09-01

    Full Text Available The aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37°C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were placed on the labial cusp of the first premolars (PM, and on the mesiolabial cusp of the second molars (M. The final acrylic resin pressing was made in a metallic flask with aid of the RS tension system, and polymerized in a moist-hot cycle at 74°C for 9 hours. The dentures were deflasked after cooling in their own polymerizing water or after cooling in polymerizing water plus bench storage for 3 hours, and stored in water at 37°C for periods of 7, 30, and 90 days. Following deflasking and after each storage period tested, the PM-PM (premolar to premolar, M-M (molar to molar, LPM-LM (left premolar to left molar, and RPM-RM (right premolar to right molar distances were measured with an STM Olympus microscope, with an accuracy of 0.0005 mm. Collected data were submitted to ANOVA and Tukey's test (5%. There was no statistically significant difference for the PM-PM, M-M, and LPM-LM distances after all storage periods when the flask cooling methods were considered. With exception of the RPM-RM distance after the 30-days water plus bench storage period, the other distances remained statistically stable.O propósito deste trabalho foi verificar a movimentação de dentes posteriores em prótese total superior armazenada em água a 37°C. Vinte próteses totais superiores foram confeccionadas com resina acrílica, com os dentes anteriores em transpasse normal e os posteriores em Classe I de Angle. Pinos metálicos foram colocados na cúspide vestibular dos primeiros pré-molares (PM e cúspide mésio-vestibular dos segundos molares (M. A prensagem final da resina acrílica foi feita em mufla metálica com auxílio do dispositivo RS de contens

  11. Pseudomembranous candidiasis in patient wearing full denture

    Directory of Open Access Journals (Sweden)

    Nurdiana Nurdiana

    2009-06-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection of the oral cavity caused by an overgrowth of Candida species, the commonest being Candida albicans. Candida albicans is a harmless commensal organism inhabiting the mouths but it can change into pathogen and invade tissue and cause acute and chronic disease. Dentures predispose to infection with Candida in as many as 65% of elderly people wearing full upper dentures. Purpose: The purpose of this case report is to discuss thrush in patient wearing full denture which rapidly developed. Case: This paper report a case of 57 year-old man who came to the Oral Medicine Clinic Faculty of Dentistry Airlangga University with clinical appearance of pseudomembranous candidiasis (thrush. Case Management: Diagnosis of this case is confirmed with microbiology examination. Patient was wearing full upper dentures, and from anamnesis known that patient wearing denture for 24 hours and he had poor oral hygiene. Patient was treated with topical (nystatin oral suspension and miconazole oral gel and systemic (ketoconazole antifungal. Patient also instructed not to wear his denture and cleaned white pseudomembrane on his mouth with soft toothbrush. Conclusion: Denture, habit of wearing denture for 24 hours, and poor oral hygiene are predisposing factors of thrush and it can healed completely after treated with topical and systemic antifungal.

  12. Glass fiber reinforcement in repaired acrylic resin removable dentures: preliminary results of a clinical study.

    Science.gov (United States)

    Vallittu, P K

    1997-01-01

    The clinical usefulness of continuous E-glass partial fiber reinforcement of acrylic resin removable dentures was evaluated an average 13 months after the insertion of the fibers. Twelve removable complete dentures and ten removable partial dentures with a history of recurrent fracture were selected for this study. The partial fiber reinforcement was incorporated into the denture at the time of repair. One complete denture and one removable partial denture fractured in the region of reinforcement during the examination period. These fractures were most likely caused by faulty placement of the fiber reinforcement in the denture in the dental laboratory. In six dentures, new fractures occurred in regions without partial fiber reinforcement. The results revealed the importance of both the correct positioning of the partial fiber reinforcement in the denture and the use of accurate laboratory techniques.

  13. Will wearing dentures affect edentulous patients' breathing during sleep?

    Science.gov (United States)

    Chen, Qiuwen; Zou, Dong; Feng, Hailan; Pan, Shaoxia

    2017-01-14

    The purpose of this study is to investigate the effect of wearing dentures on obstructive sleep apnea and hypopnea among completely edentulous patients. A self-controlled study was conducted among 30 edentulous patients. Polysomnograms were recorded in the sleep laboratory on two consecutive nights. Participants slept with their dentures in one night and without dentures in the other. The apnea and hypopnea index (AHI), lowest oxygen saturation (L-SpO2), and morning blood pressure (MBP) were collected for statistical analysis. Among the edentulous participants, 24 showed a higher AHI when sleeping with dentures. The average AHI for all 30 participants was significantly higher when they slept with dentures than without dentures (16.3 ± 14.7 vs 13.4 ± 14.0/h, P dentures) had a significant increase in AHI when sleeping with dentures, and nearly half of them (5 out of 11) reached the diagnostic standard for OSAHS (AHI >5). A higher morning diastolic blood pressure was recorded when participants slept with dentures (P dentures can lead to significant increase of AHI and diastolic MBP among edentulous people. Hence, we suggest that Chinese edentulous people should remove their dentures before sleep. ChiCTR-IOR-16008404.

  14. Kinesiographic study of mandibular movements during functional adaptation to complete dentures Estudo cinesiográfico dos movimentos mandibulares durante o período de adaptação funcional a próteses totais

    Directory of Open Access Journals (Sweden)

    Cláudio Rodrigues Leles

    2003-12-01

    Full Text Available After complete denture insertion, edentulous patients usually present transitory difficulties. This is one of the most critical stages of prosthetic treatment and it is strongly related to the prostheses acceptance. The aim of this study was to evaluate potential changes in the mandibular movement pattern related to insertion of the complete denture during the functional adaptation period. The kinesiograph instrument K6-I (Myotronics Research Inc., Seattle, WA was used to evaluate eight edentulous patients that received conventional complete denture treatment. Recordings of opening and closure movement limits, movement velocity, postural rest position, chewing cycle and limits of eccentric movements were performed. Each patient was evaluated in four different stages: with the old dentures, immediately after insertion of the new dentures, and 30 days and 6 months after insertion of the dentures. The results showed that there were no remarkable changes in the mandibular motion patterns after insertion of the new dentures. It was suggested that the problems related to the process of utilization of new dentures are not strictly associated to the mandibular movement. Therefore, functional adaptation after denture insertion is not directly related to functional changes, but to the quality of the dentures and to individual features.Após a instalação de próteses totais, o paciente desdentado geralmente enfrenta dificuldades transitórias. Esse estágio é um dos mais críticos durante o tratamento protético desses pacientes, estando relacionado à aceitação das próteses. O presente estudo teve como objetivo avaliar as possíveis alterações no padrão de movimentos mandibulares decorrentes da instalação de próteses totais em indivíduos desdentados, durante o período de adaptação funcional. O sistema de diagnóstico cinesiográfico K6-I (Myotronics Research Inc., Seattle, WA foi empregado para avaliação de 08 pacientes que foram

  15. Influence of Different Methods for Making the Secondary Impression on the First Using Effects of Complete Dentures%不同方法制取二次印模对全口义齿初戴效果的影响

    Institute of Scientific and Technical Information of China (English)

    李乐

    2016-01-01

    Objective Discusses the influence of different methods for making the secondary impression of complete dentures on the primary stability, the number of initial pressure point and the initial satisfaction. Methods Make the individual tray respectively using the direct method, indirect method and combination method for 20 patients with tooth jaw to obtains the ifnal impression,3 pair of denture made respectively. Early wear of teeth, when comparing the initial stability of the 3 pair of denture, the number of pressure points and test patients satisfaction in terms of denture solid and comfortable. Results Under the active muscle molding, the early stability of complete denture which impression made by the indirect method is better than which made by the direct method, then the combination method is better than the indirect method. The number of initial pressure point:the indirect method and the combination method are both less than the direct method, then there is no prominent difference in the two methods. Satisfaction in solid: the combination method is better than the indirect method, the indirect method is better than the direct method. Satisfaction in comfortable:the indirect method and the combination method are both less than the direct method, then there is no prominent difference in the two method. Conclusion The combination method for making the secondary impression is the best method to make complete dentures.%目的:探讨不同方法制取二次印模对全口义齿初期稳定性、初期压迫点数目和患者初戴满意度的影响。方法采用直接法、间接法和结合法为20名无牙颌患者制作个别托盘取得终印模,分别制作3副全口义齿。初戴牙时,比较3副义齿的初期稳定性、压迫点数目及测试患者在义齿稳固和舒适方面的满意度。结果主动功能整塑运动下间接法取印制作的全口义齿初期稳定性好于直接法,结合法取印制作的全口义齿好于间接法。

  16. The trial denture.

    Science.gov (United States)

    Payne, S H

    1977-04-01

    1. Many difficult situations can be avoided if the dentist keeps constantly aware of the physiologic, the psychologic, and the artistic factors involved in the construction of dentures, whether they be partial or complete. 2. No one would think of buying an automobile without getting adequate instruction in how to drive; neither should a patient expect to wear artifical restorations without training and practice. 3. The dentist at the try-in should check: a. The bases for fit and extension. b. Thin labial flange at frenum area. c. Posterior palatal seal and length of upper. d. Posterior tooth poisition for height of plane, relation of plane to alatragus line, tongue room, and ridge relation. e. Anterior tooth position for lip support, length, and relation to lower lip. f. Entire setup for vertical dimension of the face, test balance and simultaneous tooth contacts in all desired positions. If discrepancies exist between the articulator and the mouth, make new jaw relation records. g. Check palatal contour and incisor positions in speaking. "F" and "V" sounds to test the upper incisor, sibilant sounds for vertical dimension and lower-to-upper incisal relationships. h. Wax-up for support and proper external form. If tori exist on upper or lower, be sure there is sufficient thickness to allow relief later on. i. Be sure to repeat and continue instruction of the patient in his understanding and handling of the new dentures. Now, in addition to all these checks to dentist makes, he must constantly anticipate the thoughts and attitudes of the patient and interpret them for better rapport and ultimate patient understanding. No stage in complete dentures is anticipated with such mixed emotions as is the try-in. No stage is so significant to the future success or failure of the patient to take dentures in his stride. No stage has so much potential for making the person happy or sinking him into the depths of despair. The return of self-confidence, the pride in appearance

  17. The conversion partial denture: a clinical report.

    Science.gov (United States)

    Waliszewski, Michael P; Brudvik, James S

    2004-04-01

    The treatment alternative described maximizes the benefit of remaining teeth while allowing simplified alteration of the prosthesis if abutments are lost during the life span of the removable partial denture (RPD). A conversion partial is an RPD whose tooth-frame assembly components are individually fabricated and then joined with an acrylic resin major connector. The conversion RPD optimizes retention and stabilization of a terminal dentition and can be easily converted to an immediate complete denture.

  18. Clinical effects of glazing denture acrylic resin bases using an ultraviolet curing method.

    Science.gov (United States)

    Budtz-Jörgensen, E; Kaaber, S

    1986-12-01

    Control of denture plaque accumulation is essential to obtain and maintain a healthy oral mucosa in denture wearers. The present study was designed to study the effect on denture plaque accumulation and denture stomatitis of coating the fitting denture surface by a glaze. Twenty-one subjects wearing complete dentures participated in the study. Glazing of the denture surface was performed using a Perma Cure System. Plaque accumulation was studied clinically and using a semiquantitative microbiologic technique. Plaque accumulation on the glazed and the non-glazed halves of the fitting denture surface was compared after 1 wk. There was significantly less plaque on the glazed half of the denture (P less than 0.001), and the calculated number of CFU of bacteria/cm2 was significantly lower from the test area of the glazed half than from the test area of the non-glazed half of the denture (P less than 0.001). When the patients were re-examined 1 month after the entire fitting denture surface had been glazed plaque scores, yeast scores and number of CFU of bacteria/cm2 were not significantly different from those observed before glazing. There was a reduction of the erythema of the palatal mucosa in 14/19 patients with denture-induced stomatitis. The study indicates that coating of the fitting denture surface by a glaze may be a means to improve denture cleanliness; however, the present glazing system should be further developed to produce a more uniform glazing.

  19. Swallowed dentures: Two cases and a review

    Directory of Open Access Journals (Sweden)

    Mahir Gachabayov

    2015-12-01

    Conclusion: Fixed dentures can be accidentally ingested as well as removable dentures. Denture loosening leads to accidental denture ingestion. Patients with denture loosening should be recommended to visit dentist as soon as possible.

  20. The stress distribution on the supporting tissue of the maxillary complete denture with different compensate curve%不同补偿曲线的上颌全口义齿下支持组织的应力分布

    Institute of Scientific and Technical Information of China (English)

    安晓飞; 白乐康; 牛光良

    2012-01-01

    Objective: To study the stress distribution on the supporting tissue of the maxillary complete denture with different compensate curve. Methods: The 3D FEM was used to study the stress distribution on the supporting tissue of the maxillary complete denture with different compensate curve. Results: Loading on anterior teeth, the stress concentration was obvious in the labial frenum notch zone of edentulous ridge in the fourth model. Under unilateral posterior teeth loading conditions, the stress of the third model was highest in the area of anterior palatum. Under bilateral posterior teeth loading conditions, the stress of labia frenum notch zone, incisive papilla zone, middle palatum and posterior teeth crest were highest in the third model. Loading on all the teeth, the stress was highest in the labial frenum notch zone in the fourth model. Conclusion: Under occlusal force, the stress of the supporting tissue of the maxillary complete denture with normal compensate curve was lower than that of the complete denture with abnormal compensate curve. Therefore, to protect the health of alveolar bone, it is necessary tocorrect the abnormal compensate curve of the mandible teeth before the fabrication of a maxillary denture.%目的:研究补偿曲线对上颌全口义齿基托下支持组织应力分布的影响,为预防上颌骨组织吸收提供理论依据.方法:用三维有限元应力分析法研究不同补偿曲线时上颌全口义齿基托下支持组织应力及其分布状况.结果:前牙加载时,Ⅳ号模型唇系带切迹区压应力最大;单侧后牙加载时,Ⅲ号模型腭顶区压应力最大;双侧后牙加载时,Ⅲ号模型唇系带切迹、切牙乳突、腭顶、后牙嵴顶区压应力最大;全牙列加载时,Ⅳ号模型唇系带切迹区压应力最大.结论:在(牙合)力作用下,正常补偿曲线深度较异常补偿曲线深度的全口义齿模型,义齿基托下骨组织压应力值较小.义齿修复前应对下颌天然牙进行

  1. Efficacy of biofilm disclosing agent and of three brushes in the control of complete denture cleansing Eficácia de um evidenciador de biofilme e de três escovas no controle da higiene de próteses totais

    Directory of Open Access Journals (Sweden)

    Cláudia Helena Lovato da Silva

    2006-12-01

    Full Text Available OBJECTIVE: This report evaluated the efficacy of three brushes and one biofilm disclosing agent in complete denture cleansing. METHODS: Twenty-seven wearers of maxillary dentures were distributed into three groups and received different brushes: Oral B40, conventional toothbrush (Oral B; Denture, denture-specific brush (Condor; Johnson & Johnson, denture-specific brush (Johnson & Johnson. The 60-day experimental period was divided into two techniques: I - brushing (brush associated with a paste - Dentu Creme, Dentco three times a day; II - brushing and daily application of 1% neutral red on the denture internal surface. Biofilm quantification was carried out weekly and the areas with dye biofilm were obtained by means of Image Tool 2.02 software. RESULTS: Biofilm removal was more effective during Technique II (Wilcoxon test: p=0.01 for the three groups of brushes. When the brushes were compared in Technique I, the Kruskal Wallis test indicated statistical difference between Denture X Johnson & Johnson and Denture X Oral B40, in which the Denture was more efficient. For Technique II, there was no statistical difference between brushes (p>0.05. CONCLUSION: The disclosed application promoted more efficacy on biofilm removal, regardless of the brush used. Denture (Condor was more efficient than the other brushes during Technique I.Este trabalho avaliou três escovas e um evidenciador de biofilme na higiene de próteses totais. Vinte e sete usuários de próteses totais superiores foram distribuídos em três grupos que receberam diferentes escovas: Oral B40 para dentes naturais (Oral B; Denture para dentadura (Condor e Johnson & Johnson para dentadura (Johnson & Johnson. O período experimental de 60 dias foi dividido em 2 Técnicas: I - utilização das escovas associadas a um dentifrício (Dentu-Creme, Dentco três vezes ao dia; II - escovação e aplicação diária do evidenciador Vermelho neutro a 1% na superfície interna da prótese total. A

  2. Risk factors associated with denture stomatitis in the United States.

    Science.gov (United States)

    Shulman, J D; Rivera-Hidalgo, F; Beach, M M

    2005-07-01

    This study reports denture stomatitis (DS) prevalence from a large USA probability sample from the National Health and Nutrition Examination Survey, 1988-1994 (NHANES III). Oral examinations were performed on 3450 individuals 18-90+ years of age (mean: 59.2; SD: 0.50 years), 57.7% male and 42.3% female. Multivariable logistic regression models were fitted for DS using sociodemographic, denture quality, blood analytes, alcohol and tobacco use, history of diabetes, and current antibiotic use as covariates. Odds ratios (OR), adjusted for other covariates in each model (AOR) are presented. Of 3450 removable denture wearers, 963 (27.9%) had DS. DS prevalence was associated with wearing maxillary (AOR: 6.20) and mandibular (AOR: 5.21) complete dentures continuously; smoking >/=15 cigarettes day (maxillary complete: AOR = 1.31; mandibular complete: AOR = 1.50; maxillary partial: AOR = 2.04); vitamin A deficiency (mandibular complete: AOR = 5.97; maxillary partial: AOR = 5.67; mandibular partial: AOR = 24.42). Maxillary dentures with inadequate relines had approximately half the OR of DS than those with adequate relines (maxillary complete: AOR = 0.42; mandibular complete: AOR = 0.50). Denture stomatitis prevalence is associated with the amount of tissue covered by dentures, low vitamin A levels, cigarette smoking, and constant denture wear.

  3. 应用CBCT技术对全口义齿再修复时颞下颌关节盘间隙变化的分析%Difference analysis of temporomandibular joint space after complete denture secondary restoration by CBCT

    Institute of Scientific and Technical Information of China (English)

    李国强; 钟群; 李珏

    2015-01-01

    目的:应用CBCT技术,分析全口义齿再修复时颞下颌关节盘的间隙变化,以确定患者一次垂直距离恢复的最大值,为临床提供依据。方法选择全口义齿使用超过5年的需要再修复患者30例,按常规制作新的全口义齿,根据患者全口义齿垂直距离恢复情况分为3组,A组为恢复1.0mm~2.5mm,B组为恢复2.5mm~5.0mm,C组为恢复大于5.0mm。通过自身对照,观察新旧全口义齿垂直距离改变,并在CBCT下记录颞下颌关节盘间隙变化,结合临床患者资料,分析垂直距离改变和颞下颌关节盘间隙的关系,明确垂直距离恢复程度对关节的影响。结果 A组关节盘上、前、后变化在(0.10~0.50)±0.20mm区间,患者新全口义齿一周内可适应;B组关节盘上、前、后变化在(0.50~1.11)±0.32mm区间,患者新全口义齿适应时间相对长;C组关节盘上、前、后变化在>(1.50±0.50)mm区间,患者新全口义齿失败可能性明显增加。结论全口义齿再修复时建议一次性恢复垂直距离高度以不超过2.5mm为宜,最大值在5mm以内,以减少全口义齿修复失败和诱导颞下颌关节疾病的可能,大于5mm以上明显存在失败风险。%Objective To clarify the maximum vertical dimension of occlusion on patients who received complete denture secondary restoration. Methods The 30 patients wearing complete denture more than 5 years and requiring secondary restoration were chosen for treatment with new complete denture. The change in vertical dimension of occlusion on patients between old and new denture treatment was recorded, and the change in the temporomandibular joint space was observed by CBCT, and the relationship between vertical dimension and TMJ space were analyzed according to the clinical data. Results When the vertical distance was less than 2.5mm, the patients were adapted to the new denture within one week and the temporomandibular joint

  4. 非刺激性混合睡液对全口义齿着色影响的实验研究%The effects of the unstimulated whole salivary on staining of complete dentures

    Institute of Scientific and Technical Information of China (English)

    高莹; 李长福; 张文怡; 刘娟

    2011-01-01

    Objective: To study the effects of the flow rate, pH value and the concentration of calcium, sodium, potassium in unstimulated whole salivary on staining of complete dentures. Methods: According to the extent of staining, the samples were divided into mild, moderate and severe groups. The flow rate, pH value and the concentration of calcium, sodium, potassium in salivary were measured before denture insertion and after 3 months. One-Way ANOVA and paired-samples T text were used for statistical analysis. Results: (1) The flow rate and pH value of mild group were higher than moderate and severe groups, the concentration of calcium, sodium, potassium were lower (P<0.01). (2) The flow rate after denture insertion (0.66± 0.17ml/min) was significantly higher than that before (0.50± 0.20ml/min), pH value(6.48± 0.22) was lower than that before(6.71± 0.18). There was an increase in the concentration of calcium, sodium, potassium(P<0.01). Conclusions: The flow rate, pH value and the concentration of calcium, sodium, potassium in unstimulated salivary have an influence on staining of complete dentures, while the salivary also change after denture insertion.%目的:本研究通过检测牙列缺失的患者全口义齿配戴前后非刺激性混合唾液的流率、pH值以及Ca2+、Na+、K+离子的浓度,探讨非刺激性混合唾液对全口义齿着色的影响.方法:按全口义齿着色程度的不同,将90例全口义齿配戴者分成轻、中、重度3组.对各组患者全口义齿配戴前和配戴3个月后非刺激性混合唾液的流率、pH值以及Ca2+、Na+、K+离子浓度进行检测.采用单因素方差分析和配对样本资料的t检验进行统计学分析.结果:(1)全口义齿配戴前与配戴后,轻度组的唾液流率以及pH值高于中度组和重度组,Ca2+、Na+、K+离子浓度则低于中度组和重度组,差别有统计学意义(P<0.01).(2)全口义齿配戴后唾液流率0.66±0.17mL/min高于配戴前0.50±0.20m

  5. 不同高度全口覆盖义齿短冠基牙根面临床观察%Clinical observation of different short crown root surface height complete overlay denture base

    Institute of Scientific and Technical Information of China (English)

    田丽; 杨军成

    2012-01-01

    目的探讨全口覆盖义齿基牙根面不同高度牙龈病的发病率.方法随机选择30例口内有多个残根残冠的中老年患者,选择符合条件的残根或残冠共126个基牙经治疗后.将残根残冠根面预备平整,上颌残根根面平齐龈缘,下颌残根根面高出龈缘1-2mm.根管口及根面均采用光固化树脂充填,然后进行常规全口义齿修复.观察两种不同方法牙龈炎的发病率.结果30例全口覆盖义齿患者中平齐龈缘的残根龈炎发病率较高.结论选择全口覆盖义齿修复方式时,短冠基牙残根根面高度预备最好高出龈缘1-2mm,可以预防牙周炎的发生.%Objective : Study of complete overdenture based on root surface in different height of gingival disease incidence rate Methods: In 30 randomly selected patients with a number of residual root and crown in the elderly patients, Selection of eligible residual roots or crowns in a total of 126 abutment teeth after the treatment, The residual crown and root to root surface preparation leveling, maxillary residual root surface flush gingival margin, Mandibular residual root surface above the gingival margin 1-2mm, Root canal orifice and root surface using light curing resin filling, then the conventional complete denture restoration. Observe the effect of two different methods the incidence of gingivitis. Results:In 30 patients with complete overlay denture patients with gingival margin in a higher incidence of residual root gingivitis. Conclusion: Selection of overlay denture repairing mode, Short crown abutment teeth residual root surface height above the gingival margin 1-2mm is the better mode, it can prevent the onset of periodontitis.

  6. Effect of vertical dimension determined by functional view on occlusal relationship satisfaction of reconstruction of complete denture%功能角度确定垂直距离对全口义齿重建咬合关系满意度的影响

    Institute of Scientific and Technical Information of China (English)

    张景林; 白月影; 王雯

    2011-01-01

    BACKGROUND: At present, for the determination of vertical dimension, vertical dimension of rest position is mostly used to reduce mean rest position gap, and combined with experience of physician, finally determine the vertical dimension of complete denture, this dimension is not necessarily maybe the optimal vertical dimension of patients.OBJECTIVE: To investigate the effect of vertical dimension determined by fu nctional view on repair satisfaction of complete dentures in patients with edentulous jaw, according to self-control functional and traditional approach.METHODS: A total of 40 patients were treated with the repairs of complete dentures, the vertical dimension was determined by functional and traditional approach to manufacture complete dentures, respectively. The dentural satisfaction of patients with edentulous jaw was tested, after the patients wore their dentures 3 months.RESULTS AND CONCLUSION: The satisfaction of co m plete dentures manufactured by functional approach was superior to that by traditional approach (P < 0.05). Functional approach can determine the vertical dimension of the repair of complete dentures.%背景:目前临床上进行全口义齿修复时,对于垂直距离的确定,多采用息止颌位垂直距离减去息止颌间隙均值,并结合医师的经验,最终确定全口义齿的垂直距离,单此距离不一定就是患者的最适的垂直距离.目的:通过自身对照比较功能法和传统法确定全口义齿垂直距离对无牙颌患者全口义齿修复满意度的影响.方法:40例进行全口义齿再修复的患者,分别采用功能法和传统的方法确定垂直距离,制作完成全口义齿.戴用3个月以后,测试无牙颌患者对义齿的满意度.结果与结论:功能法制作的全口义齿满意度高于传统法(P < 0.05),说明功能法可确定再修复全口义齿的垂直距离.

  7. Phonetics and tongue position to improve mandibular denture retention: a clinical report.

    Science.gov (United States)

    Bohnenkamp, David M; Garcia, Lily T

    2007-11-01

    The fabrication, use, and wear instructions for complete dentures are often the factors determining success. The dentist must help guide the mental attitude of the skeptical patient to foster acceptance and success of complete dentures. A "feeling of looseness" may be a condition experienced while patients learn to wear a new mandibular complete denture. Some patients may not understand the reasons given by dentists for the lack of retention of a new mandibular denture. This type of patient requires more explanation, more advice, and more instruction. A phonetic training technique, to demonstrate to the patient how to retain and stabilize the mandibular denture, may be needed for some denture patients. This article reports the clinical use of phonetics and its effect on tongue position to improve the retention and stability of a mandibular complete denture.

  8. Improved denture retention in patients with retracted tongues.

    Science.gov (United States)

    Lee, Ji-Hua; Chen, Jen-Hao; Lee, Huey-Er; Chang, Hong-Po; Chen, Hong-Sen; Yang, Yi-Hsin; Chou, Tsau-Mau

    2009-08-01

    Patients who wear mandibular dentures and hold their tongues in retracted positions alter the dimensions of the sublingual space and disrupt the peripheral seal that is needed for optimal denture retention. The authors studied whether retention could be improved if patients moved their tongues from a retracted resting position to an ideal resting position. The authors observed and classified the mandibular residual ridge morphologies of 85 participants who wore complete dentures. The authors recorded and compared the retention of the mandibular denture before and after repositioning the tongue to the ideal resting position. When the participants' tongues were in a retracted resting position, the average retention of the mandibular denture was 75.38 gram weight (+/- 81.83 standard deviation [SD]). After participants repositioned their tongues to the ideal resting position, the average retention of the mandibular denture was 118.89 gw (+/- 93.00 SD), an increase of 57.73 percent. In all morphological classes, when participants held their tongues in the ideal resting position, the average mandibular denture retention increased by 57.73 percent, a statistically significant improvement compared with when participants held their tongues in a retracted resting position. Clinicians are encouraged to evaluate carefully the tongue resting position in all patients who wear dentures, help create reasonable therapeutic expectations by informing patients about the significant effect that tongue position will have on future denture retention and provide helpful neuromuscular training for patients with retracted-tongue habits.

  9. Denture quality has a minimal effect on health-related quality of life in patients with removable dentures.

    Science.gov (United States)

    Inoue, M; John, M T; Tsukasaki, H; Furuyama, C; Baba, K

    2011-11-01

    The present study examined the association of denture quality and health-related quality of life (HRQoL) in patients with removable dentures. In a study of 171 consecutive patients with removable partial dentures or complete dentures (mean age: 68·0 ± 9·3 years) at a university-based prosthodontic clinic, dentists rated two aspects of denture quality (stability and aesthetics) using a 100-mm visual analog scale (VAS). HRQoL was evaluated using the mental and physical component summary (MCS and PCS) scores of the Medical Outcomes Study Short-Form 36-Item Health Survey (SF-36). Oral health-related quality of life (OHRQoL) was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J). The associations among denture quality, OHRQoL, and HRQoL were examined by linear regression models. Bivariable linear regression analyses revealed that denture stability was significantly associated with the SF-36 MCS [regression coefficient = 0·52 for a 10-unit increase in denture stability on a 0-100 VAS, 95% confidence interval (CI): 0·03-1·00, P = 0·04], but not with the PCS (0·11, 95% CI: -0·49 to 0·70). Denture aesthetics was not related to the PCS or the MCS (0·22, 95% CI: -0·44 to 0·88 or 0·07, 95%CI: -0·47 to 0·62). When OHIP-J was added to the regression model, this variable was substantially and significantly associated with the MCS and PCS summary scores; in addition, the regression coefficient for denture quality decreased in magnitude and was statistically nonsignificant in all analyses. The quality of removable dentures had a minimal effect on HRQoL in patients with removable dentures, and this association was mediated by OHRQoL. © 2011 Blackwell Publishing Ltd.

  10. Electromyographic Evaluation of the Effect of Lined Dentures on Masticatory Muscle Activity in Edentulous Subjects

    Science.gov (United States)

    Srivastava, Shitij; Gaur, Abhishek; Dupare, Arun; Rastogi, Shiksha; Kamatagi, Laxmikant

    2015-01-01

    Aim The purpose of this study was to examine changes in relative electromyographic (EMG) activities of temporal and masseter muscles after relining the dentures with silicone and acrylic-resin based denture liners. Materials and Methods Conventional complete dentures were fabricated for 20 edentulous patients. One month after completing adjustments of the dentures, electromyography of the masseter and temporalis muscle during maximum intercuspation was recorded. The dentures were then relined with a silicone denture liner and after an adaptation period of one month, were again subjected for electromyographic evaluation. Further, the dentures were relined with acrylic denture liner and subjected to electromyographic evaluation. Data was analysed using Statistical Package for Social Sciences (SPSS) version 15.0. Intergroup comparisons were done using ANOVA followed by post-hoc assessments using Tukey HSD test. Results Mean amplitude and duration with conventional dentures was found to be significantly lower as compared to silicone lined and acrylic lined dentures for all the comparisons. Statistically, no significant difference between silicone lined and acrylic lined dentures was observed for any of the comparisons. Conclusion Within the limitations of this experimental design, it was concluded that relining significantly increases electromyographic activity of the masseter and temporalis muscles. Thus, resulting in an improved biting force, chewing efficiency and masticatory performance. There were no significant differences between silicone and acrylic based denture liners for both electromyographic variables. PMID:26436054

  11. Relationship among local and functional factors in the development of denture stomatitis in denture wearers in northern Brazil

    Directory of Open Access Journals (Sweden)

    Lurdete Maria Rocha GAUCH

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the relationship among functional and qualitative factors in the development of denture stomatitis (DS (according to Newton's classification in acrylic-based denture wearers residents from northern Brazil.MATERIAL AND METHOD: A total of 99 patients who wore partial or total acrylic resin-based upper dentures were included in this study. The subjects completed an epidemiological data form that includes the patient's gender, age, local factors (hygiene habits, remove denture to sleep, use of mouthwash, present condition of the denture, age of the denture and functional factors (vertical dimension at rest, vertical dimension of occlusion, occlusion, retention, and static and dynamic stability. To detect yeasts, samples were collected from the inner surface of the dentures and from the palatal mucosa in contact with it. Subsequently, the samples were cultured on Sabouraud dextrose agar, observing macro and microscopic characteristics.RESULT: In the present study, we did not find any significant relationship between the gender and disease onset. Based on the Newton classification, 36.3% of the patients presented with DS and 89.0% were colonized by yeasts; of these subjects, 50% had type I lesions, 33.3% had type II lesions, and 16.6% had type III lesions. All of the qualitative and local factors, except the use of mouthwash, were clinically relevant to the development of disease.CONCLUSION: Denture stomatitis in denture users in northern Brazil was multifactorial, involving local, functional and microbiological factors.

  12. 无牙颌全口义齿再修复患者的颌位记录方法%Jaw relationship recording for patients who need complete denture again

    Institute of Scientific and Technical Information of China (English)

    孙学武

    2011-01-01

    无牙颌再修复颌位记录的内容包括垂直颌位关系和水平颌位关系以及铰链轴关系.因无牙颌全口义齿修复的患者旧义齿使用多年,其(牙合)关系多表现为牙位与肌位的不一致.如果在全口义齿再次修复时不及时调整这种颌位关系的不当,最终会诱导或加重颞下颌关节紊乱综合征的发生;因此,确定无牙颌全口义齿修复患者适宜的颌位关系是预防和治疗颞下颌关节紊乱综合征的重要方法,也是再次修复成败的关键.本文就垂直颌位关系的记录、水平颌位关系的记录和铰链轴关系的记录等研究进展作一综述.%Jaw relationship recorded for patients who need complete denture again includes the vertical dimension, the horizontal relation, and the hinge axis relation. For edentulous patients with denture repair again, who use the old dentures for many years, most of their jaw relationships is characterized as the inconformity between inter-cuspal position and muscular contact position. If not to adjust the jaw improper position, it can eventually induce or aggravate temporomandibular joint disorder syndrome. Therefore, to determine the appropriate jaw relationship is the way to prevent and treat temporomandibular joint disorder syndrome, and the key to do the restoration successfully. In this paper, the research progress on jaw relationship, which includes the vertical dimension, the horizontal relation, and the hinge axis relation were reviewed.

  13. Trial of an experimental castor oil solution for cleaning dentures.

    Science.gov (United States)

    Andrade, Ingrid Machado de; Andrade, Kelly Machado de; Pisani, Marina Xavier; Silva-Lovato, Cláudia Helena; de Souza, Raphael Freitas; Paranhos, Helena de Freitas Oliveira

    2014-01-01

    Denture hygiene is essential because denture biofilm is involved in oral infections and systemic diseases. Although there are chemical agents available on the market, none of them have ideal properties and research on such products is still necessary. The aim of this study was to evaluate the efficacy of a castor bean (Ricinus communis)-based solution for removing denture biofilm, compared to two traditional products (sodium hypochlorite and alkaline peroxide). Fifty maxillary complete denture wearers were instructed to brush their dentures after meals and to immerse their dentures once a day in the following solutions: Saline (20 min; control), Polident alkaline peroxide (3 min), NaOCl (20 min) and 2% castor oil solution (20 min). Participants used each solution for a period of 7 consecutive days, according to a random sequence. After each period, the internal surfaces of maxillary complete dentures were stained with a disclosing solution (1% neutral red), photographed and the disclosed biofilm was quantified with the aid of specific software. The influence of treatments on results was verified by the Friedman test (α=0.05). Tested solutions presented significant difference (Fr=51.67; poil presented intermediate results (median: 1.0% and 1.5%, respectively). It can be concluded that the castor oil solution tested in this study was comparable to alkaline peroxide in terms of efficiency in denture biofilm removal.

  14. Extensive fixed partial dentures on mandibular canine teeth: a 5-year recall study.

    Science.gov (United States)

    Carlson, B R; Yontchev, E; Carlsson, G E

    1989-01-01

    Twelve patients were followed for 5 years after treatment with a 12-unit cantilever fixed partial denture on the mandibular canines opposed by a complete maxillary denture. Two fixed dentures had to be removed, one because of an abutment tooth root-fracture and one because of rapid marginal bone loss in a terminal stage of leukemia. Caries and periodontal lesions were rare, but other complications, principally related to endodontics, occurred. All complications were amenable to standard treatment procedures. Extensive mandibular cantilever fixed partial dentures may be used in the rehabilitation of patients with a very reduced dentition and a history of difficulties in adapting to removable dentures.

  15. Does wearing dentures change sensory nerve responses under the denture base?

    Science.gov (United States)

    Ito, Nana; Kimoto, Suguru; Kawai, Yasuhiko

    2014-03-01

    The standard textbook on complete dentures suggests the necessity of relief for the incisive and posterior palatine foramina of denture wearers to prevent the impingement of the nerves and vessels passing through these foramina. However, concrete evidence of the effect of dentures on the sensory function of the nerves underlying dentures is lacking. The study aim was to investigate the influence of denture-induced compression on sensory nerve responses to stimulations. Only partially edentulous patients of maxillary Kennedy class II who wear dentures (WD) or who never wear dentures (ND) were recruited as participants. The WD and ND groups had 15 participants with a mean age of 66.9 years and 22 participants with a mean age of 60.2 years, respectively. Current perception thresholds (CPTs) at 2000, 250 and 5 Hz, corresponding to A-beta, A-delta and C fibres, respectively, were measured by the Neurometer(®) NS3000 device and compared between groups. The data were analysed by the t-test, the paired t-test and analysis of covariance adjusted for age, sex and thickness of the mucosa. The CPTs showed large differences at 2000 Hz but no differences at the other frequencies when the WD and ND groups were compared. Only the CPT of the edentulous side at 2000 Hz was significantly different between groups. Wearing removable partial dentures contributes to changes of responses to stimulations in the large fibre of the sensory nerve underlying the maxillary alveolar ridge. © 2012 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  16. Comparative study of methods for the quantification of biofilm on complete dentures Estudo comparativo de métodos para quantificação de biofilme em próteses totais

    Directory of Open Access Journals (Sweden)

    Helena de Freitas Oliveira Paranhos

    2004-09-01

    Full Text Available This study compared the application and reliability of 4 methods for biofilm quantification (computerized, paper-weighing, point-counting, and planimetric in complete dentures, verifying the correlation between them. The internal surfaces of 62 complete dentures were stained (5% erythrosine and photographed. The slides were projected on paper, and the areas (total and biofilm-covered were outlined with a pencil. These areas were measured with an equidistant point grid (point-counting method, a digital planimeter (planimetric method, and for the paper weighing method they were cut and weighed with a precision scale. For the computerized method, ImageTool software was used. In order to perform a validation test of the methods, all of them were applied to slide projections of geometric figures with known dimensions. The correlation tests showed high correlation values (r = 0.82 to 0.99 among the methods. The validation test (ANOVA showed no statistically significant differences among the values obtained from the measurement of figures using all four quantitative methods and the real dimensions of these geometric figures. Quantitative methods were efficient and reliable for measuring quantity of biofilm in complete dentures, and may be useful in experimental studies on the efficacy of hygiene products. The computerized method was fast and easy to perform.Este estudo comparou a aplicação e a confiabilidade de quatro métodos de quantificação de biofilme (computadorizado, pesagem de papel, contagem de pontos e planimétrico em próteses totais, verificando a correlação entre eles. As superfícies internas de 62 próteses totais foram coradas (eritrosina a 5% e fotografadas. Os diapositivos foram projetados em papel, e as áreas (total e com biofilme corado foram contornadas com grafite. Estas áreas foram medidas com uma grade de pontos eqüidistantes (método de contagem de pontos, um planímetro digital (método planimétrico e, para o m

  17. Complete English as a Foreign Language Teach Yourself

    CERN Document Server

    Stevens, Sandra

    2010-01-01

    The best-selling complete course for a fun and effective way to learn English as a foreign language. This ISBN is for the paperback book. The corresponding audio support (ISBN: 9781444105483) is also available. The book and audio support can also be purchased as a pack (ISBN: 9781444102376).

  18. DENTURE WEARER: ALCALIGENES SPECIES

    African Journals Online (AJOL)

    associated with Alcaligenes species infection in a patient using an upper single ... patient was HIV negative and VDRL screening for syphilis was also negative. ... status of denture and the underlying oral mucosal, to prevent opportunistic.

  19. Sectional dentures revisited.

    Science.gov (United States)

    Karir, Naveen; Hindocha, Vishali; Walmsley, A Damien

    2012-04-01

    Sectional dentures are constructed in separate parts which join together intra-orally to create a single prosthesis. They are used to exploit undercuts around teeth, hard and soft tissues which require more than one path of insertion, and are usually of split pin or locking bolts design. By using two case studies, we aim to illustrate the provision of sectional dentures and to which situations their uses are best suited. A 30-year-old male was referred to the Department of Prosthetics at the Birmingham Dental Hospital for a replacement upper partial cobalt chrome denture of a Kennedy Class IV bounded saddle. The patient had a history of failed upper cobalt chrome removable partial dentures owing to loss of retention and poor stability over the previous 12 months. A 40-year-old female patient was referred by her GDP for restoration of a bounded saddle in the lower right quadrant with a history of intolerance to previous dentures. These two cases demonstrate the successful use of sectional dentures in the aesthetic zone. Although more technically demanding, they lie well within the scope of general practice and offer patients alternative solutions from dental implants and bridgework. These cases highlight the importance of the use of alternative prosthetic techniques which can be simple and achievable for all practitioners. Sectional dentures are a treatment modality for the edentulous space where the presence of one or more undercuts prevents restoration by more conventional techniques. This paper highlights some of the situations in which sectional dentures can be employed and emphasizes their use in general practice.

  20. Temporomandibular disorders in patients with removable partial dentures: prevalence according to Kennedy classification

    OpenAIRE

    2013-01-01

    OBJECTIVE: The aim of this study was to determine the prevalence of temporomandibular disorders in patients with removable partial dentures according to Kennedy classification. METHOD: The population consisted of patients who required care at the State University of Ponta Grossa. The patients wore complete upper and lower removable partial dentures between 1 to 5 years. The patients were divided into five groups (n = 15): G1: wearer of complete maxillary denture opposed by a Class I (Kennedy)...

  1. A conventional microwave oven for denture cleaning: a critical review.

    Science.gov (United States)

    Brondani, Mario Augusto; Samim, Firoozeh; Feng, Hong

    2012-06-01

    Denture cleaning should be quick and easy to perform, especially in long-term care facilities. The lack of proper oral hygiene can put older adults at higher risk from opportunistic oral infections, particularly fungal. As an alternative to regular brushing, the use of a microwave oven has been suggested for cleaning and disinfecting dentures. To synthesise and discuss the advantages and disadvantages of the use of a conventional microwave oven for cleaning and disinfecting complete dentures. A brief literature search focused on papers dealing with microwave therapy for denture cleaning through PubMed Central, Cochrane Database of Systematic Reviews, Google Scholar, Ovid MEDLINE(R) In-Process, and Scifinder Scholar. One hundred and sixty-seven manuscripts published in English with full text were found, and 28 were accepted and discussed in the light of the advantages and disadvantages of the use of conventional microwave oven for cleaning and disinfecting complete dentures. There was no standardisation for microwave use for denture cleaning. Manual cleaning still seemed to be the optimal method for controlling fungal infection and denture stomatitis. However, such a daily routine appeared to be underused, particularly in long-term care facilities. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  2. Sputter deposition of pure titanium onto complete denture base of Ti-6Al-4V deformed by superplastic forming. Chososei keiseishita Ti-6Al-4V gishi zenbusho eno sputter jochaku ni yoru jun Ti no hifuku

    Energy Technology Data Exchange (ETDEWEB)

    Kato, M.; Sonoda, T. (Government Industrial Research Institute, Nagoya, Nagoya (Japan))

    1991-07-01

    In order to improve the biocompatibility of TiNi shape memory alloy and Ti-6Al-4V alloy of functional Ti base alloys which are paid attention as the dental materials or implant materials, the sputter deposition coating using bio-inactive Ti metal was studied. DC source was superior to RF source in characteristics of sputtered film and the rate of deposition. The wiping with gauze impregnated by acetone followed by the ultrasonic cleaning was more effective for the precleaning of the substrate. The sputtered Ti film thickness was nearly proportional to electric power and showed the orientation which depended highly on the heating temperature of the substrate. The complete surface of denture base of Ti-6Al-4V deformed by superplastic forming was well coated with pure Ti and the prospect of biocompatibility of this Ti alloy could be obtained. But the film deposited by the heating condition showed the different characteristics of film compared with that formed under the cooling condition, and it is necessary that the effect of this on the biocompatibility must be investigated. 10 refs., 11 figs.

  3. Influence of educational materials on the hygiene and utilization habits of denture wearers.

    Science.gov (United States)

    Ferruzzi, Fernanda; Martins, Julio Cesar Leonard Sabczak; Mori, Aline Akemi; Santin, Gabriela Cristina; Kurihara, Eduardo; Sabio, Sergio

    2015-01-01

    The objective of this study was to investigate the influence of educational materials on the denture hygiene and utilization habits of 70 adult volunteers who had been using complete dentures for at least 5 years. On the day they received new dentures, 32 patients were provided with an illustrated leaflet and verbal instructions on oral hygiene and utilization habits, while the remaining 38 participants were advised to continue cleaning and wearing their new dentures as they had their previous dentures. After a 6- to 10-week period, 66 of 70 subjects were interviewed about socioeconomic factors, denture hygiene, and utilization habits. The percentage of patients with a proper denture care routine was low in both groups, suggesting that patients had a tendency not to change old habits. However, statistical analysis showed a positive correlation between receiving instruction and performing denture care in a way that is closer to the recommended method: brushing without toothpaste, using a specific brush; soaking in a sodium hypochlorite solution; and removing the prosthesis at night. Within the limitations of this study, it was concluded that this approach to patient education could be applied to improve the hygiene and utilization habits of denture wearers as well as encourage the correct use of complete dentures.

  4. Developing a software for removable partial denture design: Part II: Introduction of RPD graph software

    Directory of Open Access Journals (Sweden)

    Nejatidanesh F

    2007-06-01

    Full Text Available Background and Aim: Designing removable partial dentures is one of the most important phases of prosthetic treatments. Computer can be used to facilitate and increase accuracy of removable partial denture design. The aim of this study was to develop a software for removable partial denture design.Materials and Methods: A questionnaire (discussed in part I and major textbooks, were used to determine the design rules.  The software (RPD Graph was developed using Visual C++ and Maryam program. The RPD Graph can determine the classification of partial edentulous arch. With defining the missing teeth and providing data about prognosis and conditions of abutment teeth, the removable partial design will be developed by RPD Graph. This software is a knowledge-based system which has specific characteristics. It can be used as an educational tool for teaching RPD design and as a clinical tool for supporting clinician's decision. In addition it can be developed to more complete softwares.

  5. Denture labeling: A new approach

    Directory of Open Access Journals (Sweden)

    Pardeep K Bansal

    2011-01-01

    Full Text Available The need for denture labeling is important for forensic and social reasons in case patients need to be identified individually. The importance of denture marking has long been acknowledged by the dental profession. Over the years, various denture marking systems have been reported in the literature, but none till date fulfills all the prescribed ADA specifications. A simple, easy, inexpensive procedure for marking accurate identification marks on dentures with a lead foil is described here. The label caring the patient information is incorporated in the acrylic resin during the denture processing.

  6. The effect of three different investing materials on complete denture flasking deformation%三种包埋材料对全口义齿蜡型形变大小的影响

    Institute of Scientific and Technical Information of China (English)

    夏岩; 张志宏; 黄琛琛

    2013-01-01

    目的 研究不同包埋材料对全口义齿蜡型包埋前后的形变影响.方法 采用普通石膏、超硬石膏、超硬石膏+硅橡胶三种不同包埋材料,分别包埋下颌全口义齿蜡型,按随机数字表法分三组,各8个.采用金属型盒包埋及传统水浴加热,测量四个标记点在包埋前蜡型上及热处理后甲基丙烯酸酯树脂基托上的标记点间距离并观察义齿表面光滑度.结果 普通石膏组对标记点形变量的改变最大,平均值在175~267μm,超硬石膏组与硬膏硅胶组标记点形改变量接近,AB间距离(F=3.768,P=0.040)及总均数(F=4.830,P=0.019)的改变量在三种材料间差异有统计学意义,两两比较显示,普通石膏组AB间距离及总均数的改变量均大于超硬石膏组和硬膏硅胶组,但超硬石膏组与硬膏硅胶组间差异均无统计学意义.三组间光滑度差异有统计学意义(x2=17.575,P<0.01),硬膏硅胶组的光滑度最好.结论 普通白石膏组在包埋形变上最大且表面光滑度最差,超硬石膏组包埋的形变最小,而超硬石膏+技工用硅橡胶联合包埋组的形变与单纯超硬石膏包埋组接近且表面光滑度最好.%Objective To investigate the effect of different investing materials on the complete denture flasking deformation.Methods The denture wax casts were invested by plaster,dental stone,and dental stone together with silicone,respectively.8 trial dentures were randomly chosen from above each group,and 4 reference points were selected in the cast.The conventional water bath polymerization system was used for the process.The distance between reference points were measured before and after thermally processing the Acrylic base.F test and Kruskal-Wallis H test were applied for statistical analysis.Results The distance between A and B (F =3.768,P =0.040) and the mean of total distance among O,A,B and C(F =4.830,P =0.019) had statistically significant differences among the three groups

  7. Prevalence of Candida spp. among healthy denture and nondenture wearers with respect to hygiene and age

    Directory of Open Access Journals (Sweden)

    Bharathi Prakash

    2015-01-01

    Full Text Available Dentures are inert and nonshading surfaces and therefore get easily colonized by Candida species. Subsequent biofilm produced by them lead to denture stomatitis and candidiasis. This study was aimed to understand the prevalence of Candida species among healthy denture and nondenture wearers with respect to their age and hygiene status. Swabs were collected from 50 complete dentures and 50 non-denture wearers and processed on Sabouraud′s dextrose agar. Identification of Candida species was done by staining and a battery of biochemical tests. Data obtained was correlated with age & oral hygiene and statistical analysis was performed. Candida was isolated from both denture and nondenture wearers. Prevalence of different Candida species was significantly higher in denture wearers and found predominated by C. albicans, C. tropicalis, C. dubliensis and C. glabrata. Among nondenture wearers, C. albicans and C. tropicalis were isolated. Prevalence of Candida increased with increasing age among denture wearers. Men presented declining denture hygiene compared to women with increasing age. In comparison to nondenture wearers, multispecies of Candida colonized the dentures thus presenting higher risk of candidiasis especially with increasing age.

  8. Prevalence of Candida spp. among healthy denture and nondenture wearers with respect to hygiene and age.

    Science.gov (United States)

    Prakash, Bharathi; Shekar, Malathi; Maiti, Biswajit; Karunasagar, Indrani; Padiyath, Sreeshma

    2015-01-01

    Dentures are inert and nonshading surfaces and therefore get easily colonized by Candida species. Subsequent biofilm produced by them lead to denture stomatitis and candidiasis. This study was aimed to understand the prevalence of Candida species among healthy denture and nondenture wearers with respect to their age and hygiene status. Swabs were collected from 50 complete dentures and 50 non-denture wearers and processed on Sabouraud's dextrose agar. Identification of Candida species was done by staining and a battery of biochemical tests. Data obtained was correlated with age & oral hygiene and statistical analysis was performed. Candida was isolated from both denture and nondenture wearers. Prevalence of different Candida species was significantly higher in denture wearers and found predominated by C. albicans, C. tropicalis, C. dubliensis and C. glabrata. Among nondenture wearers, C. albicans and C. tropicalis were isolated. Prevalence of Candida increased with increasing age among denture wearers. Men presented declining denture hygiene compared to women with increasing age. In comparison to nondenture wearers, multispecies of Candida colonized the dentures thus presenting higher risk of candidiasis especially with increasing age.

  9. Kinesiographic study of complete denture movement related to mucosa displacement in edentulous patients Estudo cinesiográfico da movimentação da prótese total resultante da deformação da fibromucosa em desdentados totais

    Directory of Open Access Journals (Sweden)

    Marco Antonio Compagnoni

    2003-12-01

    Full Text Available The mucosa that covers the residual ridges of edentulous patients may present some distortion or displacement when occlusal loading is applied in complete dentures. This distortion and movement of the denture can result in acceleration of residual ridge resorption and loss of retention and stability. The aim of this study was to analyze the pattern of upper complete denture movement related to underlying mucosa displacement. A sample of 10 complete denture wearers was randomly selected, which had acceptable upper and lower dentures and normal volume and resilience of residual ridges. The kinesiographic instrument K6-I Diagnostic System® was used to measure denture movements, according to the method proposed by Maeda et al.7, 1984. Denture movements were measured under the following experimental conditions: (A 3 maximum voluntary clenching cycles and (B unilateral chewing for 20 seconds. The results showed that under physiological load, oral mucosa distortion has two distinct phases: a fast initial displacement as load is applied and a slower and incomplete recovery when load is removed. Intermittent loading such as chewing progressively reduces the magnitude of the denture displacement and the recovery of the mucosa is gradually more incomplete.Devido às características de compressibilidade da fibromucosa, a incidência de cargas sobre a prótese total resulta na movimentação da prótese em direção ao rebordo, a qual pode resultar no aumento da reabsorção do rebordo residual, na desadaptação interna e na perda de retenção da prótese. O objetivo do presente estudo é avaliar o padrão de movimentação da prótese total superior em função da deformação da fibromucosa. Foram selecionados 10 pacientes usuários de próteses totais bimaxilares, com retenção satisfatória e relações oclusais corretas e rebordos alveolares com volume e grau de resiliência normais. Para a análise da movimentação da prótese total superior foi

  10. Multilocus sequence typing (MLST) analysis of Candida albicans isolates colonizing acrylic dentures before and after denture replacement.

    Science.gov (United States)

    Choo, Khai How; Lee, Hee Ji; Knight, Nicholas J; Holmes, Ann R; Cannon, Richard D

    2017-08-01

    Yeast, in particular Candida albicans, are the principal fungal cause of denture stomatitis, and can also be present as a commensal in many individuals. Few studies, however, have examined oral retention of yeast strains over time. We analyzed the yeast present in saliva samples and from the dentures of 10 individuals colonized with yeast but with no signs of stomatitis, before new complete maxillary dentures were fitted and also at 1, 3, and 6 months after denture replacement. Yeast species were presumptively identified on selective agar plates and were present in nine individuals before denture replacement and in six at the 6-month time point. C. albicans was detected in seven individuals pre-replacement, and in three by 6 months post-replacement. Sixty-two isolates (up to five from each C. albicans-positive sample) were analyzed by multilocus sequence typing (MLST) (33 from saliva and 29 from dentures). Six MLST allele profiles were identified that were common to several individuals. These profiles included three previously reported diploid sequence types (DSTs) and three novel DSTs. Two of the novel DSTs were closely related variants of a previously reported DST, and both showed loss of heterozygosity polymorphisms within one of the seven MLST gene sequences. For three individuals, at least one DST that was present before denture replacement was still detected in either saliva or on dentures at subsequent sampling times. Our results indicate that denture replacement reduces but does not remove, colonising yeast and confirm previous observations of C. albicans strain microevolution. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Categorical analysis of factors affecting needs and demands for removable dentures among Alexandria Dental Research Center clientele.

    Science.gov (United States)

    Zeid, W M; Mohamed, M H; Mahdy, N H; El-Tabakh, S M

    1999-01-01

    An accurate assessment of dental needs is important to public health planners. With this information, it is possible to assess future treatment needs and demands for services including those for removable dentures. The present work aimed to estimate the magnitude and types of needs, and demands for partial or complete removable dentures, to study some factors that may affect the identified needs and demands for removable dentures, in addition to studying the factors that may affect satisfaction with the dentures. The present study was conducted in "Alexandria Dental Research Center". Data were collected by means of interview questionnaire, followed by dental examination of all patients attending the center for the sake of removable dental restorations for a period of 6 months. A further follow up over a period of three months was undertaken to the 330 cases recorded. About one third of the cases demanded partial and/or complete dentures and were above 60 years old. The first purpose for construction of new dentures was mastication, followed by cosmetics. Only one quarter of cases decided to have delayed immediate dentures. Diabetics and those having chronic diseases showed more demand for complete dentures. The most discriminating variable between the demand for different dentures was the missing in the lower anterior teeth followed by missing in the upper both anterior and posterior and then missing in the upper anterior teeth. Satisfaction score increased with advance of age, among males, among those for complete dentures, and those who had had previous dentures. Stepwise logistic regression revealed that the best predictor for overall satisfaction was the history of having previous dentures. Results of the present study, suggest that early screening and treatment of diabetic patients, gathering detailed information by means of a questionnaire before new dentures fabrication may be an important tool for the dentist in predicting and consequently enhancing patient

  12. Course Management System's Compatibility with Teaching Style Influences Willingness to Complete Training

    Science.gov (United States)

    Pereira, Audrey Smith; Wahi, Monika Maya

    2017-01-01

    Although course management systems (CMSs) provide technology platforms that help faculty members adopt better techniques for teaching and learning, and training contributes to faculty information technology (IT) use, many higher education faculty members do not complete CMS training programs, resulting in underuse of CMSs. Therefore, the overall…

  13. Clinical research on curative effect of complete denture with two kinds of occlusion for temporomandibular joint disorders of aged edentulous patients%两种(牙合)型全口义齿对老年无牙颌患者颞下颌关节紊乱病影响的比较

    Institute of Scientific and Technical Information of China (English)

    毓天昊; 张宁; 钟丽芳; 王佟辉; 战德松

    2013-01-01

    Objective To compare curative effect between complete denture with lingualized occlusion and anatomic occlusion on temporomandibular joint disorders (TMD) of aged edentulous patients with severe residual alveolar ridge resorption.Methods Seventy aged edentulous patients with severe residual alveolar ridge resorption were recruited in this study and randomly assigned into two groups,thirty-five each.In Group A,patients received complete denture with lingualized occlusion,and in Group B,patients received complete denture with anatomic occlusion.The condition of TMD was examined and recorded by the same TMD specialist at baseline,3 months and 6 months following denture delivery.The recovery effect of TMD was evaluated according to Fricton Index.Related data were analyzed statistically with t-test and rank sum test.Results Three months following denture delivery,the craniomandibular index (CMI) decrease value was (0.064 ± 0.022) in group A,and was significantly higher than that in group B (0.043 ± 0.018) (P < 0.01).Six months following denture delivery,the CMI decrease value was (0.084 ± 0.020) in group A,and was significantly higher than that in group B(0.070 ±0.021) (P =0.011 <0.05).Conclusions Complete denture with lingualized occlusion may be more conducive to the remission of TMD for aged edentulous patients with severe residual alveolar ridge resorption.%目的 观察舌侧集中(牙合)型与解剖验型全口义齿对牙槽嵴低平的老年无牙颌患者颞下颌关节紊乱病(tempromadibular joint disorders,TMD)的疗效,以期为临床全口义齿修复的(牙合)型选择提供依据.方法 采用随机数字表法随机选取剩余牙槽嵴低平的老年无牙颌TMD患者中拟行舌侧集中(牙合)型(A组)与解剖(牙合)型(B组)全口义齿修复的患者各35例.检查并记录患者修复前和修复后3、6个月的TMD情况,采用Fricton颞下颌关节功能临床检查表评价TMD改善效果,选用t检验和秩和检验分

  14. Süperpozisyon apareyleri (*) (Overlay Dentures)

    OpenAIRE

    Muğan, Nuri; Cansevergil, Esengün

    2013-01-01

    SUMMARYRemovable partial or complete prothèses which are used to alleviate maxillary constriction and discrepancies in vertical -dimension are called « overlay dentures». The patients maxillary teeth or ridge is overiayed by acriylic and the artificial teeth are positioned in accordance with the mandibular teeth to establish a better occlusion as well as to improve the estetios of the individual. The improved anterior tooth relationships also provide the anatomic basis for the correct produc...

  15. Polyvinyl siloxane template aids in recontouring natural teeth opposing single dentures.

    Science.gov (United States)

    Javid, N; Esquivel, J F

    1996-09-01

    This article describes a procedure that provides proper reduction of natural teeth opposing complete dentures. By use of a polyvinyl siloxane prosthetic template, natural dentition can be reduced to a more favorable plane, which will facilitate denture construction. This procedure will eliminate the risk of arbitrary grinding and will minimize guesswork through guided intraoral reduction.

  16. Removable partial dentures without rests.

    Science.gov (United States)

    Meinig, D A

    1994-04-01

    Ever since Bonwill recommended the use of rests on removable partial dentures in 1899, rests have been universally considered inviolate and have gone unchallenged and untested. The author claims that removable partial dentures without rests may not cause the adverse conditions usually predicted, such as gingival stripping, gingival inflammation, mutilated residual ridges, or extensive and rapid resorption of the alveolar ridges. In removable partial dentures made by the author for several patients, the residual ridge remained stable and in physiologic equilibrium when rests were not used. A history of the long-term effect on patients wearing partial dentures with and without rests is presented.

  17. The effect of various factors on the masticatory performance of removable denture wearer

    Science.gov (United States)

    Pratama, S.; Koesmaningati, H.; Kusdhany, L. S.

    2017-08-01

    An individual’s masticatory performance concerns his/her ability to break down food in order to facilitate digestion, and it therefore plays an important role in nutrition. Removable dentures are used to rehabilitate a loss of teeth, which could jeopardize masticatory performance. Further, there exist various other factors that can affect masticatory performance. The objective of this research is to analyze the relationship between various factors and masticatory performance. Thirty-four removable denture wearers (full dentures, single complete dentures, or partial dentures) participated in a cross-sectional study of masticatory performance using color-changeable chewing gum (Masticatory Performance Evaluating Gum Xylitol®). The volume of saliva was evaluated using measuring cups, while the residual ridge heights were measured using a modified mouth mirror no. 3 with metric measurements. The residual ridge height and removable-denture-wearing experience exhibited a significant relationship with masticatory performance. However, age, gender, saliva volume, denture type, and the number and location of the missing teeth did not have a statistically significant association with masticatory performance. The residual ridge height influences the masticatory performance of removable denture wearers, since the greater the ridge height, the better the performance. The experience of using dentures also has a statistically significant influence on masticatory performance.

  18. Role of salivary and candidal proteins in denture stomatitis: an exploratory proteomic analysis.

    Science.gov (United States)

    Byrd, Warren C; Schwartz-Baxter, Sarah; Carlson, Jim; Barros, Silvana; Offenbacher, Steven; Bencharit, Sompop

    2014-07-29

    Denture stomatitis, inflammation and redness beneath a denture, affects nearly half of all denture wearers. Candidal organisms, the presence of a denture, saliva, and host immunity are the key etiological factors for the condition. The role of salivary proteins in denture stomatitis is not clear. In this study 30 edentulous subjects wearing a maxillary complete denture were recruited. Unstimulated whole saliva from each subject was collected and pooled into two groups (n = 15 each), healthy and stomatitis (Newton classification II and III). Label-free multidimensional liquid chromatography/tandem mass spectrometry (2D-LC-MS/MS) proteomics on two mass spectrometry platforms were used to determine peptide mass differences between control and stomatitis groups. Cluster analysis and principal component analysis were used to determine the differential expression among the groups. The two proteomic platforms identified 97 and 176 proteins (ANOVA; p stomatitis groups. Three proteins including carbonic anhydrase 6, cystatin C, and cystatin SN were found to be the same as previous study. Salivary proteomic profiles of patients with denture stomatitis were found to be uniquely different from controls. Analysis of protein components suggests that certain salivary proteins may predispose some patients to denture stomatitis while others are believed to be involved in the reaction to fungal infection. Analysis of candidal proteins suggests that multiple species of candidal organisms play a role in denture stomatitis.

  19. [Comparative analysis of unilateral removable partial denture and classical removable partial denture by using finite element method].

    Science.gov (United States)

    Radović, Katarina; Čairović, Aleksandra; Todorović, Aleksandar; Stančić, Ivica; Grbović, Aleksandar

    2010-01-01

    Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral free- end saddle denture without major connector was taken into consideration. The aim was to analyze and compare a unilateral RPD (removable partial denture) and a classical RPD by calculating and analyzing stresses under different loads. 3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made). The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar. The Fault Model Extractor (FME) analysis and calculation showed the complete behaviour of unilateral removable partial denture and abutments (canine and first premolar), as well as the behaviour of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits. Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values

  20. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  1. Bonding of acrylic denture teeth to resin denture bases.

    Science.gov (United States)

    Geerts, G A V M; Stuhlinger, M E

    2012-07-01

    Anterior teeth debonding from dentures is a common problem. This study tested the bond strength of denture teeth to two types of denture resin, with and without grooving the ridge-lap surface. Bond strength and fracture type of three different groups were compared: 1. Teeth bonded to heat-cured polymethyl methacrylate (PMMA); 2. Teeth bonded to pour-type PMMA; 3. Grooved teeth bonded to pour-type PMMA. Specimens were manufactured following ISO standard 22112. Force values at failure were analysed using one-way analysis of variance, using the mixed procedure with confidence interval of 95%. Types of failure were identified as adhesive, cohesive or combination. In descending order, mean failure forces were 418.55N (Group One), 367.55N (Group Two) and 290.05N (Group Three). There was no significant difference between the means of groups 1 and 2 (p = 0.0627). Group Three differed from both other groups (p denture teeth (83% and 72% respectively); group Three showed predominantly cohesive fractures within the denture PMMA (75%). Without ridge-lap modification, the bond strengths of denture teeth to pour-type and heat-cured denture resin were similar. Failures were predominantly of cohesive nature within the teeth themselves. Grooving the ridge-lap reduced fracture resistance and led to breakages predominantly in denture PMMA.

  2. Denture hygiene knowledge, attitudes, and practices toward patient education in denture care among dental practitioners of Jabalpur city, Madhya Pradesh, India.

    Science.gov (United States)

    Suresan, Vinay; Mantri, Sneha; Deogade, Suryakant; Sumathi, K; Panday, Pragya; Galav, Ankit; Mishra, Kanika

    2016-01-01

    Researchers have concentrated their focus on denture wearer's attitude and practice toward denture cleansing despite the fact that they should be more focused on the attitudes of the dentists' themselves towards patient education at the time of denture delivery. It is an obligation of every dentist to motivate, instruct and provide the means and methods of plaque control for their patients. The aim was to assess the denture hygiene knowledge, attitudes and practice towards patient education in denture care among dental practitioners (DPs) of Jabalpur city, Madhya Pradesh, India. A total of 168 dental practitioners completed a comprehensive questionnaire. All participants signed an informed consent before answering the questionnaire. The institutional review committee approved the study. Chi-square test for non-parametric study was employed to determine the statistical difference between the two groups. A P-value of 0.05 was considered to be statistically significant. Most of the subjects were qualified with a bachelor degree 142 (85%). 25 (18%) subjects did not associate oral biofilms on complete denture with conditions like denture stomatitis and other serious systemic diseases. Approximately half of the DPs 69 (48%) and specialists 8 (31%) agreed that explaining denture hygiene instructions to old patients can be very time consuming. A recall program for their patients is of importance according to 39 (27%) of DPs and 3 (12%) specialists. It may be concluded that the study subjects had limited knowledge of denture cleansing materials and denture hygiene importance. Attitudes varied among the subjects when it came to sharing information with their patients.

  3. Titanium versus polymethyl methacrylate resin complete denture base A phonology evaluation%纯钛金属与聚甲基丙烯酸甲酯树脂材料基托全口义齿修复后的语音学评价

    Institute of Scientific and Technical Information of China (English)

    姚希; 谢雷; 陆支越

    2010-01-01

    背景:有研究表明口腔中修复体的范围、厚度和形态直接影响患者的语音功能,而纯钛金属基托和树脂基托由于材料厚度的不同对语音功能的影响有所不同.目的:通过分析配戴纯钛金属基托与聚甲基丙烯酸甲酯树脂基托全口义齿同一患者的计算机语音学参数,探讨上颌义齿基托对语音功能的影响.方法:用计算机语音分析系统及语音分析软件PRAAT4.4.34对同一患者分别配戴纯钛金属基托义齿、聚甲基丙烯酸甲酯树脂基托义齿提取辅音/x,sh,r,zh,ch,j,q/第一强频集中区频率值、辅音/g,k,zh,ch,j,q/嗓音起始时间值进行统计学分析,并对两组舌根塞音三维语谱图进行观察比较.结果与结论:聚甲基丙烯酸甲酯树脂基托全口义齿由于基托厚度较大而在一定程度上不利于患者语音功能的恢复,选择纯钛金属基托义齿,减少舌腭区基托厚度更有利于患者语音功能的恢复.结果提示用计算机语音分析系统提取分析第一强频集中区频率值和嗓音起始时间等语音学参数对患者配戴全口义齿后语音清晰度分析具有客观性,上颌义齿舌腭区基托材料厚度越小,越有利于患者语音功能的恢复.%BACKGROUND: Several studies have demonstrated that the range,thickness and morphology of oral prosthesis directly influence patient's phonetic function,and titanium base and polymethyl methacrylate(PMMA)resin base yield different influences on phonetic function due to different thicknesses of materials.OBJECTIVE: To analyze the phonetic parameters in one complete denture patient who wear titanium base and PMMA resin base simultaneously and investigate the influences of maxillary complete denture base on phonetic function.METHODS: Through the use of computer-based voice analysis software PRAAT4.4.34,frequency value of the first concentrated frequency area when speaking consonant sounds/x,sh,r,zh,ch,j,q/and voice onset time when

  4. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  5. The Phonetic Evaluation on the Patients Wearing Titanium and Polymethylmethacrylate (PMMA) Resin-based Complete Dentures%纯钛金属与聚甲基丙稀酸甲酯树脂基托全口义齿修复后的语音学评价

    Institute of Scientific and Technical Information of China (English)

    姚希; 谢雷; 戴永雨

    2011-01-01

    Objective To compare the computerized phonetic parameters of the patients with titanium and polymethylmethacrylate (PMMA) resin-based dentures and to discuss the influence of denture base on the phonetics of patients. Methods The first concentrated frequency area (CFA1)of consonant /x/,/sh/,/r/,/zh/,/ch/,/j/,/q/and the voice onset time (VOT) of /g/,/k/,/zh/,/chi/,/j/,/q/were statistically analyzed in the same patients while wearing titanium denture and PMMA denture.The CSL Model 4150 (KAY, US) and PRAAT4.4.34 (KAY, US) software were used in this study.In addition, the 3D spectrograms of velar stops were compared between the two circumstances.Results The consonant articulation data showed significant differences between the two types of dentures. The CFA1 values of /x/,/sh/,/r/,/zh/,/ch/,/j/and/q/ when the patients wearing titanium dentures were lower than the data when wearing PMMA dentures(P<0.05). The VOTs of/zh/,/ch/and/j/ in titanium group were higher than those of the PMMA group(P<0.05). The VOTs of /g/and/k/ in titanium group were lower than the PMMA group(P<0.05).A redundant spike located prior to the inherent spike could be observed in the /g/and/k/ spectrograms of 78.6% of the patients while wearing PMMA-based dentures. However, no similar results were observed when they wore titanium dentures. Conclusion The results indicate that the thinner the glosso-palate base plate, the better the phonetic rehabilitation outcome will be. Therefore, the titanium denture base is recommended as a more suitable choice for the patients because it can reduce the thickness of glosso-palate base plate and then facilitate the recovery of phonetic functions. CFA1 and VOT based CSL are effective phonetic parameters to analyze the speech intelligibility of patients with complete dentures.%目的 通过对分别佩戴纯钛金属基托与聚甲基丙稀酸甲酯(PMMA)树脂基托全口义齿患者的计算机语音学参数进行分析,探讨上颌义齿基托

  6. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    Science.gov (United States)

    Qamheya, Ala Hassan A.; Yeniyol, Sinem; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient. PMID:26557392

  7. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    Directory of Open Access Journals (Sweden)

    Ala Hassan A. Qamheya

    2015-01-01

    Full Text Available Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC material in teeth construction to rehabilitate a complete denture wearer patient.

  8. Long-Term Soft Denture Lining Materials

    Science.gov (United States)

    Chladek, Grzegorz; Żmudzki, Jarosław; Kasperski, Jacek

    2014-01-01

    Long-term soft denture lining (LTSDL) materials are used to alleviate the trauma associated with wearing complete dentures. Despite their established clinical efficacy, the use of LTSDLs has been limited due to the unfavorable effects of the oral environment on some of their mechanical and performance characteristics. The unresolved issue of LTSDL colonization by Candida albicans is particularly problematic. Silicone-based LTSDL (SLTSDL) materials, which are characterized by more stable hardness, sorption and solubility than acrylic-based LTSDLs (ALTSDLs), are currently the most commonly used LTSDLs. However, SLTSDLs are more prone to debonding from the denture base. Moreover, due to their limitations, the available methods for determining bond strength do not fully reflect the actual stability of these materials under clinical conditions. SLTSDL materials exhibit favorable viscoelastic properties compared with ALTSDLs. Furthermore, all of the lining materials exhibit an aging solution-specific tendency toward discoloration, and the available cleansers are not fully effective and can alter the mechanical properties of LTSDLs. Future studies are needed to improve the microbiological resistance of LTSDLs, as well as some of their performance characteristics. PMID:28788163

  9. Long-Term Soft Denture Lining Materials

    Directory of Open Access Journals (Sweden)

    Grzegorz Chladek

    2014-08-01

    Full Text Available Long-term soft denture lining (LTSDL materials are used to alleviate the trauma associated with wearing complete dentures. Despite their established clinical efficacy, the use of LTSDLs has been limited due to the unfavorable effects of the oral environment on some of their mechanical and performance characteristics. The unresolved issue of LTSDL colonization by Candida albicans is particularly problematic. Silicone-based LTSDL (SLTSDL materials, which are characterized by more stable hardness, sorption and solubility than acrylic-based LTSDLs (ALTSDLs, are currently the most commonly used LTSDLs. However, SLTSDLs are more prone to debonding from the denture base. Moreover, due to their limitations, the available methods for determining bond strength do not fully reflect the actual stability of these materials under clinical conditions. SLTSDL materials exhibit favorable viscoelastic properties compared with ALTSDLs. Furthermore, all of the lining materials exhibit an aging solution-specific tendency toward discoloration, and the available cleansers are not fully effective and can alter the mechanical properties of LTSDLs. Future studies are needed to improve the microbiological resistance of LTSDLs, as well as some of their performance characteristics.

  10. Prevalence and possible predictors of the occurence of denture stomatitis in patients older than 60 years

    Directory of Open Access Journals (Sweden)

    Čanković Miloš

    2017-01-01

    Full Text Available Background/Aim. Denture stomatitis (DS is one of the most common oral health problems among elderly population with removable dentures. Despite the high prevalence, etiology of the disease is not completely understood. It appears to be multifactorial, with a predominance of local factors. The aim of the study was to determine the prevalence and risk factors that contribute to the development of DS in upper removable denture wearers. Methods. This clinical study comprised three groups of subjects with upper removable dentures: the DS group, and the positive and negative control groups. Swab samples were taken from the tongue and palatal mucosa for microbiological examination. Data of denture age, dentures night wearing, unstimulated salivary flow rate (USFR and saliva pH values were evaluated for all the participants. Results. The prevalence of DS was found to be 26.5%. Significantly higher values of overnight wearing (p = 0.000 and the mean age of dentures (p = 0.022 were found in the DS group compared to the controls. In relation to the positive mycological finding, a borderline significance difference among the groups was confirmed (p = 0.053. No significant association was found between DS and gender, age, the type of dentures, USFR, pH of saliva and bacteria findings. The patients who wore dentures at night had 26 times more chances to get DS compared to the patients who did not wear them overnight. Conclusion. This study confirms similar characteristics of DS prevalence in elderly population of Vojvodina compared to European. Continuous (overnight wearing of dentures is considered to be major direct risk factor for DS development, while secondary role is attributed to denture age and oral Candida infection.

  11. Dentures as Learning Materials for Maxillomandibular Fixation by Erich Arch Bars.

    Science.gov (United States)

    Aksam, Ersin; Aksam, Berrak

    2016-03-01

    Maxillomandibular fixation with Erich arch bars is an economic method for handling mandibular fractures. Unfortunately, this method has some disadvantages, such as long operating time, periodontal trauma, and risk of puncture injury to the operator. To overcome these disadvantages, we propose teaching the pits and pearls of maxillomandibular fixation with Erich arch bars to trainees using dentures of a patient. Experiencing the method on dentures will shorten the learning curve.

  12. Retention of denture bases fabricated by three different processing techniques – An in vivo study

    Science.gov (United States)

    Chalapathi Kumar, V. H.; Surapaneni, Hemchand; Ravikiran, V.; Chandra, B. Sarat; Balusu, Srilatha; Reddy, V. Naveen

    2016-01-01

    Aim: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. Materials and Methods: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. Results: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. Conclusions: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique. PMID:27382542

  13. Prosthetic stomatitis with removable dentures

    Directory of Open Access Journals (Sweden)

    Rozalieva Yu.Yu.

    2012-06-01

    Full Text Available The Research Objective: To study patients with prosthetic stomatitis, who use the removable laminar dentures. Materials: The consultations and treatment of 79 patients aged 47-65 years have been conducted. The patients have been divided into two clinical groups. The first clinical group (39 persons with the performance of immediate prosthet-ics; the second control clinical group (40 persons — the permanent dentures were produced without the preliminary instruction. Results: All the patients, having the laminar dentures without the preliminary use of immediate constructions of dentures, in spite of repeated correction of them, have had changes of dentures and transitory fold. Patients have been exposed to prosthetic stomatitis of different etiology (without trauma; the single-shot or multiple correction of dentures by the method of rebasing with using of cold cure plastics has been made. Conclusion: Structural and functional changes of dentition during the prosthetic stomatitis lead to disorders, associated by the mucositis. Use of the term of «prosthetic stomatitis» reflects etiological and pathogenetic component of changes in the denture-supporting tissues

  14. Fibres reinforced dentures investigated with en-face optical coherence tomography

    Science.gov (United States)

    Negrutiu, Meda L.; Sinescu, Cosmin; Hughes, Michael; Bradu, Adrian; Goguta, Luciana; Rominu, Mihai; Negru, Radu; Podoleanu, Adrian Gh.

    2008-04-01

    The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative procedures have been devised. In order to enhance the mechanical strength, complete denture bases are reinforced with fibres. Their material and structure vary wildly, which makes the investigation difficult. In this study, optical coherence tomography (OCT) is evaluated as a possible non-invasive technique to assess the biomechanical behaviour of the reinforcing fibres. OCT images demonstrate structural defects between fibres and the acrylic material in all dentures bases investigated. We conclude that OCT can successfully be used as a noninvasive analysis method.

  15. Implant-retained mandibular overdentures versus conventional dentures: 10 years of care and aftercare.

    Science.gov (United States)

    Visser, Anita; Meijer, Henny J A; Raghoebar, Gerry M; Vissink, Arjan

    2006-01-01

    This 10-year prospective, randomized, clinical trial investigated the treatment outcome of edentulous patients treated with mandibular overdentures retained by 2 endosseous implants compared with conventional dentures in patients with or without vestibuloplasty. One hundred fifty-one edentulous patients (5 groups) with a symphyseal mandibular bone height between 8 and 25 mm participated. Sixty-two patients were treated with an overdenture retained by 2 implants (groups 1 and 3), 59 patients were treated with a conventional denture (groups 2 and 5), and 30 patients were treated with a conventional denture after preprosthetic vestibuloplasty (group 4). Patients who received conventional dentures but preferred implants later on could undergo implant surgery after 1 year of their initial treatment, but were analyzed in their original group. The prosthetic and surgical care and aftercare were scored during a 10-year evaluation period. One hundred thirty-three patients completed the 10-year follow-up evaluations. Forty-four percent of patients treated with conventional dentures switched within 10 years to implant-retained overdentures, versus 16% of the patients who were treated with conventional dentures after vestibuloplasty. On average, a greater time investment and more treatment sessions were needed in patients treated with implant-retained overdentures compared to patients treated with conventional dentures. Patients treated with an implant-retained overdenture need more treatment interventions and treatment time than patients treated with conventional dentures.

  16. Biting and chewing in overdentures, full dentures, and natural dentitions

    NARCIS (Netherlands)

    Fontijn-Tekamp, FA; Slagter, AP; Van 'T Hof, MA; Witter, DJ; Kalk, W; Jansen, JA

    2000-01-01

    It has been suggested that the provision of dental implants can improve the oral function of subjects with severely resorbed mandibles, possibly restoring function to the level experienced by satisfied wearers of conventional complete dentures. Nevertheless, a quantitative comparison has never been

  17. Denture adhesives: a systematic review.

    Science.gov (United States)

    Papadiochou, Sofia; Emmanouil, Ioannis; Papadiochos, Ioannis

    2015-05-01

    Denture adhesives have been the objective of scientific research for over half a century. Although they are used by denture wearers worldwide, investigations of their effectiveness and biocompatibility have led to controversial conclusions. The purpose of this study was to review the literature data with regard to the effectiveness and biocompatibility of denture adhesives as well as the attitudes of both patients and dental professionals toward these materials. An electronic search of English peer-reviewed dental literature in the Medline database was conducted to evaluate the effectiveness and biocompatibility of denture adhesives. There was no limitation in publication year, so the search included all the available scientific evidence included in that particular database until March 2014. Specific inclusion criteria were used for the selection of the appropriate articles. A manual search of the citations of the obtained articles followed to extend the electronic search. A full text review was carried out for only 32 articles. Of the 32 articles, 21 examined the efficacy of denture adhesives in terms of retention and stability and masticatory performance, 6 evaluated the issue of the biocompatibility of denture adhesives, and 5 presented the attitudes of either professionals or patients toward these materials. The majority of clinical studies supported the fact that denture adhesives enhance the retention, stability, and masticatory performance of a removable prosthesis. In terms of biocompatibility, long-term in vivo studies to investigate potential harmful effects were lacking. Patients are satisfied with denture adhesives that meet their needs. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Rehabilitation with immediate denture

    Directory of Open Access Journals (Sweden)

    Mayelin de la Caridad Suárez González

    2015-06-01

    Full Text Available This is the case of a 42-year-old male patient, with past history of good health, active worker, who referred refusal to the period of tooth loss both for his own personality and work responsibility. On intra-buccal examination, his central superior and inferior incisors showed plenty of tooth decay that got most of his teeth structures; besides, on X-ray examination, horizontal bone loss is observed at third apical level of the present teeth and mobility grade III and IV, for what their extraction is indicated. From the prosthetic point of view, he was diagnosed as a superior and inferior partial edentulous patient, Kennedy class I. It was decided to rehabilitate by immediate superior and inferior total denture, performing previous multiple extractions with corrective alveoloplasty and alveolectomy. With the surgical and appliances treatment, excellent results were achieved, showing the effectiveness of this treatment.

  19. ORAL INJURIES ASSOCIATED WITH THE USE OF COMPLETE ENTURE

    Directory of Open Access Journals (Sweden)

    Thanny de Paula Mascarenhas Barbosa

    2011-05-01

    Full Text Available Nowadays the complete denture still is a very used method of treatment in the rehabilitation of persons who lost their teeth. Oral lesions may occur due to the use of denture with deficiency in confection, or even an inadequate orientation of the patient by the dental surgeon about the use of the dentures and its cleaning. Among the oral lesions caused by the use of complete denture most frequent were the chronic atrophic candidiasis, chronic hyperplastic candidiasis, inflammatory fibrous hyperplasia, angular cheilitis, and traumatic ulceration. A neoplasic lesion wasn’t found associated with the use of dentures. This study aims to identify through a literature review of the prevalence of major diseases due to the use of complete dentures as well as their treatments.

  20. [Denture stomatitis - definition, etiology, classification and treatment].

    Science.gov (United States)

    Cubera, Katarzyna

    2013-01-01

    Denture stomatitis pertains to a number of pathological symptoms in the oral cavity caused by wearing acrylic dentures. Etiological factors include: mucosal trauma, fungal infection and accumulation of denture plaque. All of these factors appear to increase the ability of Candida albicans to colonize both the denture and oral mucosal surfaces. Antifungal treatment can eradicate C. albicans contamination and relieve stomatitis symptoms. Early diagnosis of the lesion is essential to assure rational therapy.

  1. Case report: a tale of two dentures.

    Science.gov (United States)

    Beckett, H; Sequeira, P

    1998-12-01

    A case is presented where loss of an incisor tooth in a partial denture wearer created an aesthetic emergency. It was not possible to solve this simply by addition of a tooth to the existing denture. Reference to the previous dental history suggested that a further immediate solution might be unwise. The design of the existing denture lent itself to the novel solution of a second denture, retained by elements of the first.

  2. Effectiveness of a denture hygiene intervention programme among institutionalized elders

    OpenAIRE

    Au, Kar-yan; Cheung, Hiu-ching; Chung, Sze-man; Lai, Chi-fung; Leung, Ki-ki, Jessica; Leung, Yat-fung; Ng, Yuk-chun; Wah, Yat-shing, Jonathan; Wong, Chun-lung

    2015-01-01

    Objectives: To evaluate the effectiveness of a denture hygiene intervention programme in terms of improving denture cleanliness and denture stomatitis. Methods: Residents at seven elderly care homes were invited to participate in a denture hygiene programme. Clinical assessment of denture stomatitis was undertaken and denture cleanliness assessed: (i) qualitatively by the Denture Cleanliness Index ratings and (ii) quantitatively by planimetric assessments of plaque coverage from digital im...

  3. Impact of mandibular conventional denture and overdenture on quality of life and masticatory efficiency

    Directory of Open Access Journals (Sweden)

    Rachel Gomes CARDOSO

    Full Text Available Abstract The aim of this non-randomized controlled clinical trial was to evaluate the oral health-related quality of life and masticatory efficiency of patients rehabilitated with mandibular two-implant overdentures with immediate loading or conventional dentures. Fifty completely edentulous patients wearing bimaxillary conventional dentures, for at least one year, were recruited. The patients were then assigned to either two treatment groups: mandibular overdentures supported by two implants with bar-clip system and a maxillary conventional denture (n = 25, and new maxillary and mandibular conventional complete dentures (n = 25. Masticatory efficiency and oral health-related quality of life were assessed before and 3 months after denture insertion. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral health-related quality of life. Masticatory efficiency was evaluated with chewing capsules through a colorimetric method. The results revealed fewer oral health–related quality of life problems in patients wearing mandibular two-implant overdentures compared to the conventional dentures group. In addition, the implant overdenture group presented statistically significant improvement in masticatory efficiency (p = 0.001. There was no correlation between masticatory efficiency and OHIP in the implant group (p > 0.05, however a correlation was found in the conventional denture group (p < 0.05. Therefore, these short-term results suggest that mandibular overdenture retained by 2 implants with immediate loading combined with maxillary conventional dentures provide better masticatory efficiency and oral health–related quality of life than mandibular conventional dentures.

  4. Microwave disinfection of maxillary and mandibular denture bases contaminated with Candida Albican.

    Science.gov (United States)

    Bamigboye, S A; Dosumu, O O; Ajayi, D M

    2015-09-01

    Oral environment is not sterile, and dentures worn by the patients can be infected and therefore needs disinfection. Solution disinfectants such as sodium hypochlorite and glutaraldehyde can be used but they have side effects. Microwave disinfection method is more recent, however, there are conflicting reports at the moment on the appropriate power and time regimen for disinfection of denture. To determine the power and time regimen at which the disinfection of dentures can be achieved using microwave. Forty-five acrylic denture bases were fabricated for each of the jaws and infected with solution of a stock Candida albicans and 30 infected bases were employed as control. These were placed in normal saline and then subjected to different microwave power and time regimen. Aliquots from these post-microwave solution were titrated against sabauraud agar which was subsequently incubated at 37 degrees C for 48 hours. The agar were examined for candida growth. The denture bases subjected to microwave disinfection at 350W showed Candida growth after microwave treatment irrespective of the time employed. Conversely, those microwaved at 650W and 690W for four and six minutes showed no microbial growth. The microwave regimen of 650W at 4 and 6 minutes completely disinfected the denture bases. Disinfection at higher microwave energy should be done with caution as distortion of the denture may occur.

  5. Effectiveness of Photodynamic Therapy for the Inactivation of Candida spp. on Dentures: In Vitro Study

    Science.gov (United States)

    Mima, Ewerton Garcia de Oliveira; Ribeiro, Daniela Garcia; Dovigo, Livia Nordi; Vergani, Carlos Eduardo; Bagnato, Vanderlei Salvador

    2011-01-01

    Abstract Objective: This in vitro study evaluated the effectiveness of photodynamic therapy (PDT) for the inactivation of different species of Candida on maxillary complete dentures. Background data: The treatment of denture stomatitis requires the inactivation of Candida spp. on dentures. PDT has been reported as an effective method for Candida inactivation. Methods: Reference strains of C. albicans, C. glabrata, C. tropicalis, C. dubliniensis and C. krusei were tested. Thirty-four dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated with one of the strains and incubated at 37°C for 24 h. Dentures submitted to PDT (P+L+) were individually sprayed with 50 mg/L of Photogem® (PS) and, after 30 min, illuminated by LED light for 26 min (37.5 J/cm2). Additional dentures were treated only with PS (P+L-) or light (P-L+) or neither (P-L-). Samples of serial dilutions were spread on Sabouraud dextrose agar and incubated at 37°C for 48 h. The colonies were counted and the values of log (cfu/mL) were analyzed by Kruskall-Wallis and Dunn tests (pdentures when compared with P-L- (reductions from 1.73 to 3.99 log10). Significant differences (pdentures. PMID:21916614

  6. Unilateral removable partial dentures.

    Science.gov (United States)

    Goodall, W A; Greer, A C; Martin, N

    2017-01-27

    Removable partial dentures (RPDs) are widely used to replace missing teeth in order to restore both function and aesthetics for the partially dentate patient. Conventional RPD design is frequently bilateral and consists of a major connector that bridges both sides of the arch. Some patients cannot and will not tolerate such an extensive appliance. For these patients, bridgework may not be a predictable option and it is not always possible to provide implant-retained restorations. This article presents unilateral RPDs as a potential treatment modality for such patients and explores indications and contraindications for their use, including factors relating to patient history, clinical presentation and patient wishes. Through case examples, design, material and fabrication considerations will be discussed. While their use is not widespread, there are a number of patients who benefit from the provision of unilateral RPDs. They are a useful treatment to have in the clinician's armamentarium, but a highly-skilled dental team and a specific patient presentation is required in order for them to be a reasonable and predictable prosthetic option.

  7. The Oral Microbiome of Denture Wearers Is Influenced by Levels of Natural Dentition

    Science.gov (United States)

    O’Donnell, Lindsay E.; Robertson, Douglas; Nile, Christopher J.; Cross, Laura J.; Riggio, Marcello; Sherriff, Andrea; Bradshaw, David; Lambert, Margaret; Malcolm, Jennifer; Buijs, Mark J.; Zaura, Egija; Crielaard, Wim; Brandt, Bernd W.; Ramage, Gordon

    2015-01-01

    Objectives The composition of dental plaque has been well defined, whereas currently there is limited understanding of the composition of denture plaque and how it directly influences denture related stomatitis (DS). The aims of this study were to compare the microbiomes of denture wearers, and to understand the implications of these towards inter-kingdom and host-pathogen interactions within the oral cavity. Methods Swab samples were obtained from 123 participants wearing either a complete or partial denture; the bacterial composition of each sample was determined using bar-coded illumina MiSeq sequencing of the bacterial hypervariable V4 region of 16S rDNA. Sequencing data processing was undertaken using QIIME, clustered in Operational Taxonomic Units (OTUs) and assigned to taxonomy. The dentures were sonicated to remove the microbial flora residing on the prosthesis, sonicate was then cultured using diagnostic colorex Candida media. Samples of unstimulated saliva were obtained and antimicrobial peptides (AMP) levels were measured by ELISA. Results We have shown that dental and denture plaques are significantly distinct both in composition and diversity and that the oral microbiome composition of a denture wearer is variable and is influenced by the location within the mouth. Dentures and mucosa were predominantly made up of Bacilli and Actinobacteria. Moreover, the presence of natural teeth has a significant impact on the overall microbial composition, when compared to the fully edentulous. Furthermore, increasing levels of Candida spp. positively correlate with Lactobacillus spp. AMPs were quantified, though showed no specific correlations. Conclusions This is the first study to provide a detailed understanding of the oral microbiome of denture wearers and has provided evidence that DS development is more complex than simply a candidal infection. Both fungal and bacterial kingdoms clearly play a role in defining the progression of DS, though we were unable to

  8. The Oral Microbiome of Denture Wearers Is Influenced by Levels of Natural Dentition.

    Directory of Open Access Journals (Sweden)

    Lindsay E O'Donnell

    Full Text Available The composition of dental plaque has been well defined, whereas currently there is limited understanding of the composition of denture plaque and how it directly influences denture related stomatitis (DS. The aims of this study were to compare the microbiomes of denture wearers, and to understand the implications of these towards inter-kingdom and host-pathogen interactions within the oral cavity.Swab samples were obtained from 123 participants wearing either a complete or partial denture; the bacterial composition of each sample was determined using bar-coded illumina MiSeq sequencing of the bacterial hypervariable V4 region of 16S rDNA. Sequencing data processing was undertaken using QIIME, clustered in Operational Taxonomic Units (OTUs and assigned to taxonomy. The dentures were sonicated to remove the microbial flora residing on the prosthesis, sonicate was then cultured using diagnostic colorex Candida media. Samples of unstimulated saliva were obtained and antimicrobial peptides (AMP levels were measured by ELISA.We have shown that dental and denture plaques are significantly distinct both in composition and diversity and that the oral microbiome composition of a denture wearer is variable and is influenced by the location within the mouth. Dentures and mucosa were predominantly made up of Bacilli and Actinobacteria. Moreover, the presence of natural teeth has a significant impact on the overall microbial composition, when compared to the fully edentulous. Furthermore, increasing levels of Candida spp. positively correlate with Lactobacillus spp. AMPs were quantified, though showed no specific correlations.This is the first study to provide a detailed understanding of the oral microbiome of denture wearers and has provided evidence that DS development is more complex than simply a candidal infection. Both fungal and bacterial kingdoms clearly play a role in defining the progression of DS, though we were unable to show a defined role for

  9. Assessing Gains in Science Teaching Self-Efficacy after Completing an Inquiry-Based Earth Science Course

    Science.gov (United States)

    Gray, Kyle

    2017-01-01

    Preservice elementary teachers are often required to take an Earth Science content course as part of their teacher education program but typically enter the course with little knowledge of key Earth Science concepts and are uncertain in their ability to teach science. This study investigated whether completing an inquiry-based Earth Science course…

  10. An innovative and simple type of unconventional interim labial partial denture

    Directory of Open Access Journals (Sweden)

    Aruna J Bhandari

    2016-01-01

    Full Text Available In routine dental practice, we come across many patients who present with different contour and forms of residual ridges. These may range from severely resorbed to well-formed bulky ridges. There are certain cases in which the premaxilla is labially inclined, and therefore, there is formation of moderate to severe labial undercut. As a result, fabricating esthetic dentures is a task. In such cases, there are two treatment options, namely, surgical and nonsurgical. Surgical treatments include labial alveoloplasty, which is invasive and we have to wait until healing occurs. Hence, a nonsurgical, noninvasive treatment option for construction of complete denture is desired. The labial flanges need to be modified to decrease the fullness on wearing dentures. Thus, labial denture prosthesis is a good and viable treatment modality.

  11. Long-term observations of extensive fixed partial dentures on mandibular canine teeth.

    Science.gov (United States)

    Carlson, B R; Yontchev, E

    1996-03-01

    Twelve patients were followed for 15 years after treatment with a 12-unit cantilever fixed partial denture on the mandibular canines opposite to a complete maxillary denture. Four constructions failed and had to be removed but four were still in function after 15 years. Four patients died during the observation period still wearing their constructions. Endodontic complications, pulpal necrosis and loss of retention of posts were the most frequent, while caries and periodontal lesions were rare. The maintenance costs over the years were fairly low even compared to maintenance costs for patients treated with implants. Extensive mandibular cantilever fixed partial dentures may be used in the rehabilitation of patients with a very reduced dentition and a history of difficulties adapting to removable dentures.

  12. A Review on Denture Marking Systems: A Mark in Forensic Dentistry.

    Science.gov (United States)

    Kareker, Nikita; Aras, Meena; Chitre, Vidya

    2014-12-01

    "Identification through forensic science is an art of giving the corpse a name A real life detective work that would put even Sherlock Homes to shame." Forensic dentistry deals with proper handling and examination of dental evidence and proper evaluation and presentation of dental findings in interest of justice. The Prosthodontists are playing a very important role in forensic dentistry as they are concerned with fabrication of various prosthesis which can serve as an important tool for identification. Identification is essential requirement of any medico-legal investigation because a wrong identity may pose a problem in delivering justice. This article describes the different methods for identification/marking of the complete dentures, removable partial dentures and fixed partial dentures and the importance of denture marking in forensic investigatory purposes. The PubMed, Ebsco and Google search engines were used to gather the articles.

  13. Effects of hygiene guidance associated or not to provision of hygiene devices on habits of denture wearers

    Directory of Open Access Journals (Sweden)

    Fernanda Ferruzzi

    2015-06-01

    Full Text Available Appropriate hygiene of dentures contributes to the maintenance of oral and systemic health. However, most of denture wearers had never been instructed on how to perform daily oral/denture care. The purpose of this study is to investigate the influence of a guidance material associated or not to the provision of hygiene devices and its effect on the habits of denture wearers. Forty- eight complete denture wearers were randomly divided into three groups. Group N received no guidance on how to clean and wear their dentures, group G received an illustrated leaflet and verbal complementary instructions and group GK received the same guidance as group G and a hygiene kit for denture cleaning. After a six to ten week period they responded to a ‘hygiene and wearing habits’ questionnaire. Chi-square test was used for statistical analysis considering p < 0.05. Brushing was the most frequent cleaning method, the majority of groups N and G used toothpaste. Participants of group G and GK presented low percentages of individuals with hygiene and wearing routine considered improper. The differences between groups in hygiene and wearing routine were statistically significant (p < 0.001. The proposed guidance material yielded better results when associated to provision of hygiene devices for denture cleaning.

  14. The spectral analysis of syllables in patients using dentures.

    Science.gov (United States)

    Jindra, Petr; Eber, Miroslav; Pesák, Josef

    2002-12-01

    Changes in the oral cavity resulting from the loss of teeth and the ensuing reconstruction of a set of teeth by dentures (partial or complete) may cause changes in the speech and voice of the patient. The aim of the present investigation was to study the changes in speech and voice in patients suffering from teeth loss and the degree of speech improvement using dentures. Voice and speech parameters of a set of tested syllables were analysed in 10 patients at the 2nd Clinic of Stomatology. The analysis was carried out by means of an FFT, SoundForge 5.0 programme. Differently expressed acoustic changes in both consonants and vowels were ascertained in a percentage of the patients under examination. These concerned especially the sibilant ("s", "(see text)"), labiodental ("f", "v") and vibrating ("r", "(see text)") consonants. Changes in the FFT spectrum and air leakage in constrictive consonants were also found. In some patients the vowels, especially the closed ones ("i", "u"), may change their fundamental frequency and show noise admixture manifested as a blurred delimitation of the formants. A denture should, inter alia, render it possible for the patient to produce the same articulation to which he/she had been accustomed before the loss of teeth. For the construction of dentures the most important factors from a phonetic point of view appear to be the following: overbite, overjet, the height of the plate, the thickness of the palatal material, the incisor position, and the modelling of the ruga palatina on the hard palate. In case of wrong denture construction the acoustic changes may continue, resulting in the patient's stress load dependent upon sex, age, psychic condition and seriousness of the problem.

  15. The Complete Step-by-Step Guide to Designing and Teaching Online Courses

    Science.gov (United States)

    Thormann, Joan; Zimmerman, Isa Kaftal

    2012-01-01

    In this valuable resource, experts share deep knowledge including practical "how-to" and preventive trouble-shooting tips. Instructors will learn about course design and development, instructional methods for online teaching, and student engagement and community building techniques. The book contains successful teaching strategies, guidance for…

  16. An overlay partial denture to restore worn mandibular anterior teeth.

    Science.gov (United States)

    Samant, Asha; DeSciscio, Peter

    2014-01-01

    Restoring worn anterior mandibular teeth is a challenge, especially when teeth are small, esthetics are a concern, the long-term prognosis is questionable, and/or patient finances are an issue. This article describes an alternate treatment for a patient with a collapsed bite, missing posterior mandibular teeth, an ill-fitting complete maxillary denture with poor esthetics, and irregular, worn mandibular anterior teeth.

  17. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    Science.gov (United States)

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  18. Partial denture-- an ENT surgeon's nightmare.

    Science.gov (United States)

    Venugopal, M; Sagesh, M

    2012-11-01

    Foreign body oesophagus is one among the common otorhinolaryngology emergencies that we come across. Artificial partial denture impaction in the oesophagus is often an ENT surgeon's nightmare. This study was done in the department of otorhinolaryngology, Government Medical College Kozhikode for a period of 2 years. All patients presented with history of accidental swallowing of partial denture followed by dysphagia. Radiological evaluation was done and subsequently oesophagoscopy and removal of the denture was done. In failed cases exploration and removal of foreign body was required. Complications were found in partial denture with metal wire clasps. It is better to avoid using malfitting dentures with small base, those with metal wire clasps and be cautious of using dentures in alcoholics and unconscious patients.

  19. Brazilian Green Propolis Compared to Miconazole Gel in the Treatment of Candida-Associated Denture Stomatitis

    Directory of Open Access Journals (Sweden)

    Hermínia Marques Capistrano

    2013-01-01

    Full Text Available Aim. To evaluate the efficacy of Brazilian green propolis in comparison to miconazole gel in the treatment of Candida-associated denture stomatitis. Methods. Forty-five denture stomatitis patients, with palatal mucosa erythema levels classified according to Newtons’s criteria and with positive culture to Candida spp., were randomly divided into three treatment groups: 15 received miconazole gel 2%, 15 received propolis gel 2,5%, and 15 received propolis 24% for mouthwash. After four daily use lasting two weeks, they were reexamined for the denture stomatitis degree and for a second culture of Candida. The Wilcoxon’s test was applied to compare the results of clinical classification of the denture stomatitis and the Candida spp. colonies numbers, before and after each treatment. The Kruskall-Wallis’s test was used to compare efficacy among the three treatment groups. Results. There were a significant reduction or complete remission of denture stomatitis (P0.05. Conclusion. Brazilian green propolis has a similar effect as miconazole in the treatment of Candida-associated denture stomatitis being an alternative in the therapeutics of this condition.

  20. Brazilian green propolis compared to miconazole gel in the treatment of Candida-associated denture stomatitis.

    Science.gov (United States)

    Capistrano, Hermínia Marques; de Assis, Eliene Magda; Leal, Rosana Maria; Alvarez-Leite, Maria Eugênia; Brener, Sylvie; Bastos, Esther Margarida Alves Ferreira

    2013-01-01

    Aim. To evaluate the efficacy of Brazilian green propolis in comparison to miconazole gel in the treatment of Candida-associated denture stomatitis. Methods. Forty-five denture stomatitis patients, with palatal mucosa erythema levels classified according to Newtons's criteria and with positive culture to Candida spp., were randomly divided into three treatment groups: 15 received miconazole gel 2%, 15 received propolis gel 2,5%, and 15 received propolis 24% for mouthwash. After four daily use lasting two weeks, they were reexamined for the denture stomatitis degree and for a second culture of Candida. The Wilcoxon's test was applied to compare the results of clinical classification of the denture stomatitis and the Candida spp. colonies numbers, before and after each treatment. The Kruskall-Wallis's test was used to compare efficacy among the three treatment groups. Results. There were a significant reduction or complete remission of denture stomatitis (P 0.05). Conclusion. Brazilian green propolis has a similar effect as miconazole in the treatment of Candida-associated denture stomatitis being an alternative in the therapeutics of this condition.

  1. Oral health-related quality of life of removable partial denture wearers and related factors.

    Science.gov (United States)

    Shaghaghian, S; Taghva, M; Abduo, J; Bagheri, R

    2015-01-01

    This study aims to investigate the oral health-related quality of life (OHRQoL) in a group of removable partial denture (RPD) wearers in Shiraz (Iran), using the Persian version of the Oral Health Impact Profile (OHIP-14). Two hundred removable partial denture wearers had completed a questionnaire regarding patients' demographic characteristics and denture-related factors. In addition, the OHIP-14 questionnaire was filled out by interviewing the patients. Two measures of interpreting the OHIP-14 scales were utilised: OHIP-14 sum and OHIP-14 prevalence. The relationship of the patients' demographic characteristics and denture-related factors, with their OHRQoL was investigated. The mean OHIP-14 sum and OHIP-14 prevalence of RPD wearers were 13·80 (±10·08) and 44·5%, respectively. The most problematic aspects of OHIP-14 were physical disability and physical pain. Twenty-seven percentage and 24% of participants had reported meal interruption and eating discomfort, respectively. OHIP-14 prevalence and OHIP-14 sum were found to be significantly associated with factors representing RPD wearer's oral health such as self-reported oral health and frequency of denture cleaning. Furthermore, OHIP-14 prevalence and OHIP-14 sum were significantly associated with factors related to frequency of denture use such as hours of wearing the denture during the day and wearing the denture while eating and sleeping. Therefore, it can be concluded that the OHRQoL of the patients of the study was generally not optimal and found to be strongly associated with oral health.

  2. Hyperzincemia from ingestion of denture adhesives.

    Science.gov (United States)

    Tezvergil-Mutluay, Arzu; Carvalho, Ricardo M; Pashley, David H

    2010-06-01

    The purpose of this article is to review the recent literature that documents the serious adverse systemic effects of prolonged, excessive zinc ingestion from the overuse of denture adhesives. This condition causes elevation of serum zinc levels that result in depression of serum copper. The low serum copper levels cause bone marrow depression and widespread sensory and motor neuropathies. Epidemiologic studies revealed the source of excessive zinc intake to be from overuse of denture adhesives. Denture patients must be advised of the risks of prolonged overuse of denture adhesives.

  3. Candidal Leukoplakia on Patient with Removable Denture

    Directory of Open Access Journals (Sweden)

    Shiril Paskalis

    2013-07-01

    Full Text Available Candida infection is a common problem in patients using removable dentures, with the most frequent type is denture stomatitis. But other type of candidal infection could also happen in these patients, such as candidal leukoplakia. We reported a 61 years old female patient who complained a painful lesion under her lower removable denture. Oral examination revealed white plaque that could not be rubbed over an ulcer on the lingual part of alveolar processes under the lower removable denture plate, and also an erythematous area on palatum durum above the upper full denture. The patient was suspected to have candidal leukoplakia on the lingual part of the mandible and denture stomatitis on the palate area. The treatment consisted of nystatin oral suspension, chlorhexidine solution, multivitamins, along with denture replacement and oral health education. The entire lesion resolved within 2 months therapy. Candidal infection treatment on denture patient needs not only medication or denture replacement, but also patient compliance to achieve maximal result.

  4. Effects of different denture material on dentures restoration%不同材质的义齿基托对修复效果影响的分析

    Institute of Scientific and Technical Information of China (English)

    何华伟; 李群; 郑东翔

    2016-01-01

    目的:应用复制义齿技术制作不同材质基托,研究义齿基托材料对义齿功能发挥的影响。方法选取符合纳入标准的多数牙缺失的患者,采用复制义齿技术制作不同基托材质(纯钛、钴铬合金和树脂基托)的义齿各10件。分别对3组义齿修复体进行重量等指标的比较观察,评价固位力等初戴效果。结果经过实际测量,在义齿重量方面,上颌的纯钛组与钴铬组有明显差异(P<0.05)。从患者评价方面,初戴时大多数患者感觉纯钛组义齿异物感小,固位好,质轻;金属基托从异物感和语言方面似乎更适应患者的心理要求。结论由于解剖位置和金属材料特性的原因,口腔修复材料选择时需要考虑义齿的修复效果,并不完全取决于材料的密度。%ObjectiveDifferent denture materials were fabricated by copy denture technique to evaluate the effects of denture materials on denture function.MethodsIn the study, patients with completely or partially edentulous arches were included. 30 dentures fabricated by the copy denture technique were divided into three groups with 10 dentures each: a pure titanium group, a PMMA group and a cobalt-chormium group. The evalua-tions of the clinic outcome,including denture retention and weight,were compared among the three groups.Re-sultsThe results showed that there were significant differences in weight of dentures between the titanium palatal plate denture and cobalt-chormium denture. As shown from the patients’ evaluation, the majority of patients thought it could offer better retention, lighter weight and more comfortable experience when wear the pure titanium denture versus the cobalt-chormium denture.ConclusionA reasonable choice of denture material is not only depends on the density of different materials, but also on the anatomical location and characteristics of metal materials.

  5. Evaluation of Randomly Selected Completed Medical Records Sheets in Teaching Hospitals of Jahrom University of Medical Sciences, 2009

    Directory of Open Access Journals (Sweden)

    Mohammad Parsa Mahjob

    2011-06-01

    Full Text Available Background and objective: Medical record documentation, often use to protect the patients legal rights, also providing information for medical researchers, general studies, education of health care staff and qualitative surveys is used. There is a need to control the amount of data entered in the medical record sheets of patients, considering the completion of these sheets is often carried out after completion of service delivery to the patients. Therefore, in this study the prevalence of completeness of medical history, operation reports, and physician order sheets by different documentaries in Jahrom teaching hospitals during year 2009 was analyzed. Methods and Materials: In this descriptive / retrospective study, the 400 medical record sheets of the patients from two teaching hospitals affiliated to Jahrom medical university was randomly selected. The tool of data collection was a checklist based on the content of medical history sheet, operation report and physician order sheets. The data were analyzed by SPSS (Version10 software and Microsoft Office Excel 2003. Results: Average of personal (Demography data entered in medical history, physician order and operation report sheets which is done by department's secretaries were 32.9, 35.8 and 40.18 percent. Average of clinical data entered by physician in medical history sheet is 38 percent. Surgical data entered by the surgeon in operation report sheet was 94.77 percent. Average of data entered by operation room's nurse in operation report sheet was 36.78 percent; Average of physician order data in physician order sheet entered by physician was 99.3 percent. Conclusion: According to this study, the rate of completed record papers reviewed by documentary in Jahrom teaching hospitals were not desirable and in some cases were very weak and incomplete. This deficiency was due to different reason such as medical record documentaries negligence, lack of adequate education for documentaries, High work

  6. 不同全口义齿重衬材料的稳固性、舒适度和咀嚼功能比较研究%Comparison on the stability, comfort and chewing function of different denture materials in complete teeth repair

    Institute of Scientific and Technical Information of China (English)

    贺会平; 林彤; 谢一敦

    2014-01-01

    目的:探讨不同全口义齿重衬材料修复牙列缺失的临床效果。方法选择我院收治的90例无牙颌患者为研究对象,根据修复材料不同分为自凝组、热凝组及软衬组。比较三组修复的稳固性、舒适度及咀嚼功能恢复情况。结果重衬修复后6个月评价固位改善情况,软衬组重衬后固位Ⅲ级比例(60%)显著高于自凝组(33.3%)和热凝组(40%),软衬组重衬后悬浊液OD值(4.216±0.332)显著高于自凝组(3.109±0.312)和热凝组(3.125±0.325),软衬组固位效果(9.4±0.8)、咀嚼功能(9.3±0.7)、舒适度评分[(9.3±0.6)分]均显著优于自凝组[(6.1±0.9)分、(5.8±0.8)分、(6.0±0.9)分]、热凝组[(6.5±0.8)分、(6.3±0.8)分、(6.4±0.8)分],差异均有统计学意义(P<0.05)。结论 Sofreliner MS软衬材料固位效果良好,患者义齿舒适性高,咀嚼功能改善显著,适用于牙槽嵴吸收不均、弹性差的义齿重衬。%Objective To study the clinical effect of different denture material in complete teeth repair. Methods Ninety cases of edentulate patients with edentulous jaw were chosen as research objects, which were divid-ed into self-curing group, heat setting group and soft lining group according to different restorative materials. Repair stability, comfort and chewing function recovery were observed. Results Six months after relining repair, the retain-erⅢlevel in soft lining group was significantly higher than that in self-curing group and heat setting group (60%vs 33.3% and 40%). Suspension OD value in soft lining group (4.216 ± 0.332) was significantly higher than that in self-curing group (3.109±0.312) and the heat setting group (3.125±0.325). The retention effect, chewing function and comfort score in soft lining group [(9.4±0.8), (9.3±0.7) and (9.3±0.6), respectively] were significantly better than that in self-curing group [(6.1±0.9), (5.8±0.8) and(6.0±0.9), respectively] and heat setting group [(6.5±0.8), (6

  7. Effect of different complete denture base plates morphology on phonetics A qualitative analysis based on computerized speech lab%计算机语音分析系统对全口义齿不同基托表面形态与发音质量的定性分析

    Institute of Scientific and Technical Information of China (English)

    谢雷; 姚希; 侯倩; 戴永雨

    2009-01-01

    背景:国内外学者的研究表明,腭皱有助于辅音的形成.以往关于腭皱对伞口义齿发音影响的研究多局限于对受试者佩戴不同义齿后发音效果的主观评价.目的:应用计算机语音分析系统定性分析全口义齿腭部基托形态对无牙颌患者发音效果的影响.设计、时间及地点:对照观察,于2007-02/2008-02 在卫生部北京医院口腔科及首都医科大学附属北京友谊医院耳鼻喉科完成.对象:10例无牙颌患者,分别戴入光滑面全口义齿和有腭皱全口义齿.方法:分别应用计算机语音分析系统测量患者佩戴光滑面义齿及有腭皱义齿时发/da/,/ta/,/sa/,/na/音的二维语图及语音学参数.主要观察指标:三维语图及语音学参数冲直条、嗓音起始时问及过渡音征.结果:10例患者冲直条伞部出现.发/da/,/ta/音时,佩戴光滑面义齿时嗓音起始时间小于佩戴有腭皱义齿时(P0.05).发/da/,/a/音时,佩戴光滑面义齿时过渡音征起始点频率显著低于佩戴有腭皱义齿时(P0.05).结论:腭皱有助于恢复无牙颌患者的语音功能,有助于提高辅音发音的清晰度,在全口义齿修复时应考虑恢复.计算机语音分析系统可对全口义齿患者修复后语音变化特征进行定量分析,对临床口腔修复治疗具有很好的指导意义.%BACKGROUND:Palatal rugae assist for consonantal formation;however,effect of palatal rugae on phonetics has been previously reported to be involved in different complete denture base plates of recipients.OBJECTIVE:To qualitatively analyze the effe-cts of different palate base plate morphology on phonetics of edentulous jaw patients using a computerized speech lab.DESIGN,TIME AND SETTING:A contrast study was performed at the Department of Stomatology,Beijing Hospital of Healthy Administration,and at the Department of Otorhinolaryngology,Beijing Friendship Hospital affiliated to Capital Medical University between February 2007 and

  8. Effects of Rosmarinus officinalis essential oil on germ tube formation by Candida albicans isolated from denture wearers

    OpenAIRE

    Lurdete Maria Rocha Gauch; Fabíola Silveira-Gomes; Renata Antunes Esteves; Simone Soares Pedrosa; Ely Simone Cajueiro Gurgel; Alberto Cardoso Arruda; Silvia Helena Marques-da-Silva

    2014-01-01

    Introduction The aim of this study was to investigate the effects of Rosmarinus officinalis essential oil on germ tube formation by Candida albicans isolated from denture wearers. Methods Ten C. albicans isolates recovered from denture wearers were tested using 10% fetal bovine serum with or without 4% R. officinalis essential oil. Results The essential oil from R. officinalis completely inhibited germ tube formation in the investigated C. albicans isolates. Conclusions The results demo...

  9. Impact of removable partial denture prosthesis on chewing efficiency

    Directory of Open Access Journals (Sweden)

    Marion Bessadet

    2013-09-01

    Full Text Available Removable partial denture prostheses are still being used for anatomic, medical and economic reasons. However, the impact on chewing parameters is poorly described. OBJECTIVES: The objective of this study was to estimate the impact of removable partial denture prosthesis on masticatory parameters. MATERIAL AND METHODS: Nineteen removable partial denture prosthesis (RPDP wearers participated in the study. Among them, 10 subjects were Kennedy Class III partially edentulous and 9 with posterior edentulism (Class I. All presented a complete and full dentate opposing arch. The subjects chewed samples of carrots and peanuts with and without their prosthesis. The granulometry of the expectorated boluses from carrot and peanuts was characterized by median particle size (D50, determined at the natural point of swallowing. Number of chewing cycles (CC, chewing time (CT and chewing frequency (CF=CC/CT were video recorded. RESULTS: With RPDP, the mean D50 values for carrot and peanuts were lower [Repeated Model Procedures (RMP, F=15, p<0.001] regardless of the type of Kennedy Class. For each food, mean CC, CT and CF values recorded decreased (RMP, F=18, F=9, and F=20 respectively, p<0.01. With or without RPD, the boluses' granulometry values were above the masticatory normative index (MNI determined as 4,000 µm. CONCLUSION: RPDP rehabilitation improves the ability to reduce the bolus particle size, but does not reestablish fully the masticatory function. CLINICAL RELEVANCE: This study encourages the clinical improvement of oral rehabilitation procedure.

  10. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  11. Clinical evaluation of the essential oil of "Satureja Hortensis" for the treatment of denture stomatitis

    Directory of Open Access Journals (Sweden)

    Ali Mohammad Sabzghabaee

    2012-01-01

    Full Text Available Background: The prevalence of denture stomatitis has been shown to vary from 15 to 65% in complete denture wearers. Satureja hortensis L. has been considered to have antinociceptive, anti-inflammatory, antifungal and antimicrobial activities in vitro and exhibits strong inhibitory effect on the growth of periodontal bacteria. The aim of this study was to evaluate the efficacy of a 1% gel formulation of S. hortensis essential oil for the treatment of denture stomatitis. Materials and Methods: A randomized, controlled clinical trial study was conducted on 80 patients (mean age 62.91±7.34 in two parallel groups treated either with S. hortensis essential oil 1% gel or placebo applied two times daily for two weeks. Denture stomatitis was diagnosed by clinical examination and paraclinical confirmation with sampling the palatal mucosa for Candida albicans. Data were analyzed using Chi-squared or Student′s t tests. Results: The erythematous lesions of palatal area were significantly reduced (P<0.0001 in the treatment group who applied 1% topical gel of S. hortensis essential oil and Candida colonies count were reduced significantly (P=0.001. Conclusion: Topical application of the essential oil of S. hortensis could be considered as an effective agent for the treatment of denture stomatitis.

  12. A case with tumor of left parotid gland and denture stomatitis.

    Science.gov (United States)

    MercuŢ, Veronica; Iorgulescu, Daniel; Popescu, Sanda Mihaela; Mărgăritescu, Claudiu; MercuŢ, Răzvan; CrăiŢoiu, Monica Mihaela; Scrieciu, Monica

    2015-01-01

    The article discuss the case of an edentulous patient presented to the dental clinic for pain and burning sensation of oral mucosa and diagnosed subsequently with oxyphilic adenoma. A 58-year-old patient, with maxillary edentulism, treated with complete denture, presented to the Clinic of Prosthetic Dentistry of the Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, Romania, for pain of oral mucosa and bad stability of denture. The diagnosis of erythematous denture stomatitis as consequence of salivary flow reduction was establish after patient's clinical examination, and by unstimulated sialometry. Clinical exam suggested hyposalivation could be a consequence of a tumor situated at the level of the left parotid gland. The echography confirmed the diagnosis of left parotid gland tumor. The tumor was surgical removed and histopathological exam confirmed oxyphilic adenoma. Education of patient for wearing new denture while maintaining a strict oral hygiene and dealing with low salivary flow was the treatment for denture stomatitis. General dentist has an important role in finding and diagnosing patients with systemic diseases, especially salivary tumors.

  13. Fabrication of an Implant-Supported Fixed Interim Prosthesis Using a Duplicate Denture: An Alternative Technique.

    Science.gov (United States)

    Al-Thobity, Ahmad M

    2016-06-22

    The fabrication of an implant-supported fixed complete denture prosthesis involves multiple clinical and laboratory steps. One of the main steps is to provide the patient with an interim fixed prosthesis to evaluate the patient's esthetic and functional needs as well as to enhance the patient's psychology before proceeding to the definitive prosthesis. Different techniques for fabricating interim prostheses have been described in the literature. This report describes an alternative technique that uses a duplicate denture made of self-curing acrylic resin to fabricate an implant-supported fixed interim prosthesis. The interim prosthesis was later used as a blueprint for the definitive implant-supported hybrid prosthesis.

  14. Age, gender, dentures and oral mucosal disorders.

    Science.gov (United States)

    MacEntee, M I; Glick, N; Stolar, E

    1998-03-01

    The numbers of participants over 75 years of age in previous studies of oral health have not been sufficient to permit a full investigation of the influence of age on the mouth. In this study a disproportionate stratified random sample of 255 independent elders was selected from a list of urban voters to provide similar numbers of men and women in three age groups. The subjects were interviewed and examined, and nearly half of them had mucosal disorders. There was a significant (P angular cheilitis in particular were associated significantly with men and with the use of defective dentures. Logistic regression revealed that neither age alone nor the quality of dentures predispose to mucosal lesions, but that the odds of finding stomatitis, denture-related hyperplasia and angular cheilitis in particular increased about three-fold in denture-users, and almost doubled in men.

  15. Oral health: dentures and dental implants.

    Science.gov (United States)

    Martonffy, Andrea Ildiko

    2015-01-01

    More than 35 million Americans have lost all of their teeth, and 178 million are missing at least one tooth. Left unmanaged, tooth loss, or edentulism, can lead to nutritional deficiencies, oral pain, and poor psychosocial functioning. The family physician may be the first clinician to discuss tooth loss as a health concern with the patient. A patient who is interested in replacing missing teeth may be a candidate for dentures, implants, or a combination of these. The patient's preferences, general health, degree of edentulism, ability to follow up regularly, smoking status, and overall oral health should be considered when the prosthodontist makes recommendations for treatment. Smoking can delay tissue healing; therefore, heavy smoking may be a contraindication to implant placement. If a patient chooses dentures, the family physician should perform regular oral examinations, because up to 70% of denture wearers are affected by denture stomatitis at some point. Poor fit, poor hygiene, nighttime wearing of removable dentures, and bacterial or candidal infections can all be identified and managed by the family physician. The physician also can reinforce proper wear and care instructions for dentures and proper care of implants.

  16. The effects of denture status on nutrition.

    Science.gov (United States)

    Papas, A S; Palmer, C A; Rounds, M C; Russell, R M

    1998-01-01

    In Part I of this study, the Human Nutrition Research Center of the United States Department of Agriculture's Nutritional Status Study (NSS) of 691 independently living elderly people aged 60-98 found that poor dietary quality was associated with low educational attainment, low median family income, and self-report of partial or full dentures. In Part II, further analysis was conducted on a random subsample of 181 subjects who were examined and divided into four groups according to dentate status: two dentures, one denture, partial dentures, and teeth. In this subgroup, significant correlations were found between the quality of nutrient intake and the degree of edentulousness. Analysis of 53 nutrients plus calories from three-day food records showed a significantly higher nutritional quality of the diet in dentate volunteers than in the other groups. This difference was approximately 20% for 19 nutrients, bringing some nutrients (such as calcium) below the RDA for this age group. Although direct correlations cannot be made with actual nutritional status, the introduction of dentures could further compromise the precarious nutritional intake of the elderly population. With this in mind, dentists need to consider carefully the importance of their elderly patients maintaining at least some natural dentition and should provide adequate information on nutritional adaptations to dentures.

  17. Hardness, Cohesiveness, and Adhesiveness of Oral Moisturizers and Denture Adhesives: Selection Criteria for Denture Wearers

    Directory of Open Access Journals (Sweden)

    Keiko Fujimoto

    2016-10-01

    Full Text Available The mechanical properties of seven denture adhesives and eight oral moisturizers, all of which are commercially available, were evaluated using a texture profile analysis. A new assessment chart is proposed for the selection criteria of denture adhesive and oral moisturizers using a radar chart with three axes: hardness, cohesiveness, and adhesiveness.

  18. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis.

    Science.gov (United States)

    Nawasrah, Amal; AlNimr, Amani; Ali, Aiman A

    2016-05-23

    Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufacturer instruction for processing complete dentures. The other five groups were processed by adding different concentration of Yamani henna powder (Harazi) to the polymer in a concentration of henna: polymer 1%, 2.5%, 5%, 7.5% and 10%, respectively. Samples were incubated in artificial saliva rich with Candida albicans at 37 °C, and the effect of henna on Candida albicans was evaluated in two different methods: semi-quantitative slide count and a culture-based quantitative assay (quantitative). Variation in the number of live Candida was observed with the increase in the concentration of Yamani henna powder. It was observed that the variation in live Candida, between control group and group B (concentration of Yamani henna powder was 1%), was statistically significant with a p-value of 0.0001. Similarly, variations in live Candida were significant, when the concentration of powder was 7.5% or 10% in contrast with control group and p-values were 0.0001 and 0.001 respectively. Adding henna to acrylic resin denture could be effective in controlling Candida albicans proliferation on the denture surface; however, its effects on the physical properties of acrylic resin denture need further studies.

  19. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis

    Directory of Open Access Journals (Sweden)

    Amal Nawasrah

    2016-05-01

    Full Text Available Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufacturer instruction for processing complete dentures. The other five groups were processed by adding different concentration of Yamani henna powder (Harazi to the polymer in a concentration of henna: polymer 1%, 2.5%, 5%, 7.5% and 10%, respectively. Samples were incubated in artificial saliva rich with Candida albicans at 37 °C, and the effect of henna on Candida albicans was evaluated in two different methods: semi-quantitative slide count and a culture-based quantitative assay (quantitative. Variation in the number of live Candida was observed with the increase in the concentration of Yamani henna powder. It was observed that the variation in live Candida, between control group and group B (concentration of Yamani henna powder was 1%, was statistically significant with a p-value of 0.0001. Similarly, variations in live Candida were significant, when the concentration of powder was 7.5% or 10% in contrast with control group and p-values were 0.0001 and 0.001 respectively. Adding henna to acrylic resin denture could be effective in controlling Candida albicans proliferation on the denture surface; however, its effects on the physical properties of acrylic resin denture need further studies.

  20. A Comparative Clinical Study of the Effect of Denture Cleansing on the Surface Roughness and Hardness of Two Denture Base Materials

    Science.gov (United States)

    Moussa, Amani Ramadan; Dehis, Wessam Mohamed; Elboraey, Asmaa Nabil; ElGabry, Hisham Samir

    2016-01-01

    AIM: This study aimed to verify the influence of oral environment and denture cleansers on the surface roughness and hardness of two different denture base materials. METHODS: A total of sixteen identical removable disc specimens (RDS) were processed. Eight RDS were made from heat-cured acrylic resin (AR) and the other eight were fabricated from thermoplastic injection moulded resin (TR). Surface roughness and hardness of DRS were measured using ultrasonic profilometry and Universal testing machine respectively. Then the four RDS (two AR and two of TR) were fixed to each maxillary denture, after three months RDS were retrieved. Surface roughness and hardness of RDS have measured again. RESULTS: The surface roughness measurements revealed no significant difference (p >0.05) for both disc groups at baseline. However, both groups showed a significant increase in the surface roughness after three months with higher mean value for (TR) group. On the other hand, the (AR) group showed higher hardness mean value than (TR) group at baseline with no significant decrease in the hardness values (p >0.05) following three months follow-up period. CONCLUSIONS: Denture cleansers have an effect on the denture’s surface roughness and hardness concurrently with an oral condition which will consequently influence the complete dentures’ lifetime and patients’ satisfaction. PMID:27703578

  1. 21 CFR 872.3600 - Partially fabricated denture kit.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a... mold, by partially polymerizing the resin denture base materials while the materials are in...

  2. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    Science.gov (United States)

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  3. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.

  4. Influence of Loading Positions of Mandibular Unilateral Distal Extension Removable Partial Dentures on Movements of Abutment Tooth and Denture Base

    National Research Council Canada - National Science Library

    Xilin Jin; Sato, Masayuki; Nishiyama, Akira; Ohyama, Takashi

    2004-01-01

    Purpose: The aim of our study was to explore theeffects of different loading positions on the movementsof the abutment tooth and denture base ofremovable partial denture with unilaterallydesigned framework (RPD-U...

  5. RELATIVE IMPORTANCE OF PSYCHOLOGIC FACTORS IN DENTURE SATISFACTION

    NARCIS (Netherlands)

    VERVOORN, JM; DUINKERKE, ASH; LUTEIJN, F; VANDEPOEL, ACM

    The aim of this investigation was to explore the relative importance of psychologic variables in explaining the degree of denture satisfaction in full denture patients. A group of 125 patients who were on a waiting list to have new dentures constructed participated in this study. The patients

  6. Development of Candida-associated denture stomatitis: new insights

    NARCIS (Netherlands)

    T. Pereira-Cenci; A.A. Del Bel Cury; W. Crielaard; B. ten Cate

    2008-01-01

    Despite therapeutic progress, opportunistic oral fungal infectious diseases have increased in prevalence, especially in denture wearers. The combination of entrapment of yeast cells in irregularities in denture-base and denture-relining materials, poor oral hygiene and several systemic factors is th

  7. 21 CFR 872.3570 - OTC denture repair kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC denture repair kit. 872.3570 Section 872.3570...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3570 OTC denture repair kit. (a) Identification. An OTC denture repair kit is a device consisting of a material, such as a resin monomer system...

  8. 21 CFR 872.3300 - Hydrophilic resin coating for dentures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic resin coating for dentures. 872.3300... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3300 Hydrophilic resin coating for dentures. (a) Identification. A hydrophilic resin coating for dentures is a device that consists of a...

  9. A study of the effects of long-lasting silicone rubber soft-lined materials on the alveolar bone absorption in complete denture%硅橡胶软衬材料对全口义齿牙槽骨吸收的影响研究

    Institute of Scientific and Technical Information of China (English)

    孙珍; 侯永福; 赵兵; 许晓波; 边华琴

    2014-01-01

    Objective:To study the effects of long-lasting silicone rubber soft-lined materials on the alveolar bone ab-sorption in complete denture. Method:The cases 29 edentulous patients with the second degree of alveolar bone condition were chosen from the year 2010 to 2012,andthey had been randomly divided into two groups. Group A applied long-lasting silicone rubber soft-lined technology,while group B did not use. Linear tomography and panoramic radiography were used to measured anterior region and posterior alveolar bone height after repairing and one year after repairing. Paired t-test was used for statistical analysis. Result:the absorption of alveolar bone in posterior tooth areas was higher than in the anterior areas. Both of two measurement techniques had shown that the absorption of alveolar bone in the group A was higher than the group B. Conclusion:The change of the absorption of alveolar bone in anterior region was lower than that of the posterior region. And the application of soft-lined materials could slow down the absorption of alveolar bone.%目的:研究长效硅橡胶软衬材料对全口义齿牙槽骨吸收变化的影响。方法:选择2010~2012年我科修复牙列缺失患者29例,牙槽骨条件在二级以上,随机分为两组,研究组应用长效硅橡胶软衬技术,对照组不应用软衬材料。修复后利用曲面断层和线性体层摄影技术,定点测量前牙区和后牙区牙槽骨高度,一年后复查牙槽骨高度,进行配对t检验统计分析。结果:牙槽骨吸收变化值,后牙区高于前牙区;两种测量技术均显示软衬材料组牙槽骨吸收低于对照组。结论:牙槽骨的吸收变化,前牙区低于后牙区,软衬材料的应用可以减缓牙槽骨的吸收。

  10. The cast aluminum denture base. Part I: Rationale.

    Science.gov (United States)

    Halperin, A R

    1980-06-01

    Experiments with various casting techniques have been done, and aluminum base dentures have been made for many patients. The subjective clinical response from patients wearing aluminum dentures has not been different from patients wearing acrylic resin dentures. However, Brudvik and Holt have stated that they have had marked clinical success in using aluminum bases. A literature review on using aluminum as a denture base material has been presented, and the rationale for its use has been discussed. In part II, a technique will be described that can be used for casting aluminum denture bases.

  11. Transesophageal echocardiogram causing denture dislodgement with upper airway partial obstruction.

    Science.gov (United States)

    Ahmed, Najeeb; Shaikh, Azim

    2009-06-01

    A 30-year-old female was evaluated with transesophageal echocardiography to exclude an atrial septal defect. The patient denied having dentures or partial dentures during her pre-procedure history and immediately prior to the procedure. Following the transesophageal echocardiography it was discovered that the patient had a partial airway obstruction caused by dislodgement of her partial dentures. The case illustrates the importance of not only asking patients if they have dentures, partial dentures, or any dental appliances, but also manually checking and directly looking into patients' mouths prior to transesophageal echocardiography for any dental appliances.

  12. Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2006-03-01

    Full Text Available A resilient denture liner is placed in the part of the hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing the resilient denture liner can makes the hollow obturator has an intimate contact with the mucosa, so it can prevents the mouth liquid enter to the cavum nasi and sinus, also eliminates painful because of using the hollow obturator. Resilient denture liner is a soft and resilient material that applied to the fitting surface of a denture in order to allow a more distribution of load. A case was reported about using the hollow obturator with resilient denture liner on post hemimaxillectomy to overcome these problems.

  13. Comparative study of Candida by conventional and CHROMagar method in non-denture and denture wearers by oral rinse technique

    Directory of Open Access Journals (Sweden)

    Shruti Nayak

    2012-01-01

    Full Text Available Introduction: Candidal species colonizes the oral cavities of healthy individuals without dentures and also of denture wearers. Soft liners and tissue conditioning materials have been found to support the growth of Candida albicans which may predispose to lesions. The most important and common candidal species are C. albicans, C. tropicalis, and C. glabrata. C albicans is usually isolated from both the fitting surface of the denture and the denture-bearing mucosa of the affected patients. The aim of this study was to isolate, quantify, and speciate candidal species in non-denture wearers (controls and denture wearers (study group by the oral rinse technique. Isolation was done using Sabouraud dextrose agar (SDA. Speciation was done using conventional methods like the germ tube test, carbohydrate fermentation test, urease test, as well as the CHROMagar method. Aims and Objective: 1 To assess the prevalence of Candida in non-denture wearers and in denture wearers by oral rinse technique, with isolation on SDA; 2 to speciate and quantify Candida in non-denture wearers and denture wearers by using conventional methods (germ tube test, carbohydrate fermentation test, urease test and the CHROMagar method; 3 to assess the influence of smoking and diabetes on candidal species among the denture wearers; and 4 to assess the sensitivity and specificity of SDA and CHRO Magar Materials and Methods: Salivary samples for Candida evaluation were collected from the subjects in sterile sample containers, using the oral rinse technique. Results: C glabrata was the most commonly found species among denture wearers and non-denture wearers both by conventional and CHROMagar methods. In males, C. albicans was the predominant species, whereas C. glabrata was the predominant species in females. Candidal colonization was higher in denture wearers compared to non-denture wearers, especially among females. The CHROMagar method was more rapid compared to conventional

  14. Leaching from denture base materials in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Lygre, H.; Solheim, E.; Gjerdet, N.R. [School of Medicine, Univ. of Bergen (Norway)

    1995-04-01

    Specimens made from denture base materials were leached in Ringer Solution and in ethanol. The specimens comprised a heat-cured product processed in two different ways and two cold-cured materials. The organic compounds leaching from the specimens to the solutions were separated, identified, and quantified by a combined gas-chromatography and gas-chromatography/mass-spectrometry technique. Additives and degradation products, possibly made by free radical reactions, were released from the denture base materials. In Ringer solution only phthalates could be quantified. In ethanol solvent, biphenyl, dibutyl phthalate, dicyclohexyl phthalate, phenyl benzoate, and phenyl salicylate were quantified. In addition, copper was found in the ethanol solvent from one of the denture base materials. The amount of leachable organic compounds varies among different materials. Processing temperature influences the initial amount of leachable compounds. 36 refs., 7 figs., 1 tab.

  15. [Dimensional accuracy of microwave-cured denture base resin].

    Science.gov (United States)

    Uchida, K; Okamoto, F; Ogata, K; Sato, T

    1989-02-01

    Recently, microwave-cured denture base resin was developed, and the resin solved the problem of internal porosity which had been generated by curing the conventional denture base resins with microwave irradiation. In this study, the dimensional accuracy of microwave-cured denture base resin was compared with that of other denture base resins, such as pour-type resin, heat-cured resin and heat-shock resin. From the experiment, the following results were obtained. 1. Dimensional accuracy of microwave-cured denture base resin was better than that of heat-cured resin and heat-shock resin, and was similar to that of pour-type resin. 2. Dimensional accuracy of microwave-cured denture base resin by slow cooling method and rapid cooling method was almost the same. Those findings suggest that microwave-cured denture base resin is valuable in clinic.

  16. Effect of resilient liner on masticatory efficiency and general patient satisfaction in completely edentulous patients

    DEFF Research Database (Denmark)

    Mangtani, Nidhi; Pillai, Rajath; Babu, Dinesh;

    2015-01-01

    Objectives: To assess the effect of resilient lined denture on patient masticatory efficiency, general patient satisfaction and denture quality as compare to conventional complete denture over a period of one year. Material and methodology: A total of 28 completely edentulous patients (14 males...... denture liner – group 2). All patients were clinically evaluated to assess the denture quality, and administered questionnaires for masticatory efficiency and patients general satisfaction level at three intervals i.e. one month (T0), 6 months (T1) and 1 year post-insertion (T2). Results: Statistical...... masticatory efficiency improved significantly over time in controls, while in experimental group masticatory efficiency remained the same (p>.05) for almost all the questions. Patient general satisfaction score at different time intervals for each question showed no significant difference (P>.05) on inter...

  17. Rotational path removable partial denture design.

    Science.gov (United States)

    Jacobson, T E; Krol, A J

    1982-10-01

    A detailed description of a rotational path of insertion design for removable partial dentures has been presented. By minimizing the use of conventional clasps, this technique offers some advantages. Rotational path designs may minimize adverse periodontal response to a removable partial denture by reducing plaque accumulation and may be applied in esthetically demanding situations. The design concept involves the use of rigid retentive components that gain access to undercut areas through a rotational path of insertion. These rigid components satisfy the basic requirements of conventional direct retained design.

  18. The Denture-Associated Oral Microbiome in Health and Stomatitis.

    Science.gov (United States)

    Shi, Baochen; Wu, Tingxi; McLean, Jeffrey; Edlund, Anna; Young, Youngik; He, Xuesong; Lv, Hongyang; Zhou, Xuedong; Shi, Wenyuan; Li, Huiying; Lux, Renate

    2016-01-01

    While investigation of the microbiome on natural oral surfaces has generated a wealth of information, few studies have examined the microbial communities colonizing dentures and their relationship to oral health. To address this knowledge gap, we characterized the bacterial community associated with dentures and remaining teeth in healthy individuals and patients with denture stomatitis. The microbiome compositions of matched denture and tooth plaque samples of 10 healthy individuals and 9 stomatitis patients were determined by 16S rRNA gene pyrosequencing. The microbial communities colonizing dentures and remaining teeth in health and disease were very similar to each other. Matched denture and tooth samples from the same individuals shared a significantly higher percentage of identical phylotypes than random pairs of samples from different study participants. Despite these overall similarities, several bacterial phylotypes displayed discrete health- and stomatitis-associated denture colonization, while others were distinct in health and disease independently of the surface. Certain phylotypes exhibited differential colonization of dentures and teeth independently of denture health status. In conclusion, denture and natural tooth surfaces in health and stomatitis harbor similar bacterial communities. Individual-related rather than surface-specific factors play a significant role in the bacterial phylotype composition colonizing dentures and teeth. This individual-specific mutual influence on denture and tooth surface colonization could be an important factor in maintaining oral health in denture wearers. Discrete differences in colonization patterns for distinct genera and phylotypes warrant further studies regarding their potential involvement or utility as specific indicators of health and disease development in denture-wearing individuals. IMPORTANCE Denture stomatitis is a prevalent inflammatory condition of the mucosal tissue in denture wearers that is

  19. The effect of full denture on memory and depression status in elderly

    Directory of Open Access Journals (Sweden)

    Bahruddin Thalib

    2016-06-01

    Full Text Available Complaint that is most often found in elderly is declining or disappearing memory and tooth loss due to aging. Loss of teeth will cause a disturbance in the function of mastication and reportedly may also contribute to the occurrence of memory disorders and depression. The objective of this study was to analyze the influence of full denture use on memory capacity and depression level in elderly. Study conducted at Oral and Dental Hospital Faculty of Dentistry, University of Hasanuddin. This study was clinical experimental with non-randomized design with pre and post test. Sampling with purposive sampling technique, and there were 6 people who are willing to participate. Memory status measurement using Mini-Mental State Exam (MMSE and level of depression using Geriatric Depression Scale (GDS. Memory status and level of depression measurement performed before using full denture and one month after using full denture. Data were analyzed with statistical pair T-test. With a 95% confidence level, the results showed there is an increase in initial MMSE average value (25.67 to the final MMSE average value (26.83 with statistically significant effect, p 0,05. This study concluded that there was significant influence in using full denture on improved memory status of complete edentulous elderly, and despite there were decreased on level of depression, but it was not statistically significant.

  20. Color difference threshold determination for acrylic denture base resins.

    Science.gov (United States)

    Ren, Jiabao; Lin, Hong; Huang, Qingmei; Liang, Qifan; Zheng, Gang

    2015-01-01

    This study aimed to set evaluation indicators, i.e., perceptibility and acceptability color difference thresholds, of color stability for acrylic denture base resins for a spectrophotometric assessing method, which offered an alternative to the visual method described in ISO 20795-1:2013. A total of 291 disk specimens 50±1 mm in diameter and 0.5±0.1 mm thick were prepared (ISO 20795-1:2013) and processed through radiation tests in an accelerated aging chamber (ISO 7491:2000) for increasing times of 0 to 42 hours. Color alterations were measured with a spectrophotometer and evaluated using the CIE L*a*b* colorimetric system. Color differences were calculated through the CIEDE2000 color difference formula. Thirty-two dental professionals without color vision deficiencies completed perceptibility and acceptability assessments under controlled conditions in vitro. An S-curve fitting procedure was used to analyze the 50:50% perceptibility and acceptability thresholds. Furthermore, perceptibility and acceptability against the differences of the three color attributes, lightness, chroma, and hue, were also investigated. According to the S-curve fitting procedure, the 50:50% perceptibility threshold was 1.71ΔE00 (r(2)=0.88) and the 50:50% acceptability threshold was 4.00 ΔE00 (r(2)=0.89). Within the limitations of this study, 1.71/4.00 ΔE00 could be used as perceptibility/acceptability thresholds for acrylic denture base resins.

  1. Reinforcement of Denture Base Resins

    Directory of Open Access Journals (Sweden)

    T Nejatiant

    2005-10-01

    Full Text Available Introduction: PMMA has been the most popular denture base material because of its advantages including good aesthetics, accurate fit, stability in the oral environment, easy laboratory and clinical manipulation and inexpensive equipments since the 1930’s. However, its fracture resistance is not satisfactory. Aim: The aim of this study is to improve the fracture resistance of denture bases made of PMMA by assessing the effect of resin type, packing and processing variables on biaxial flexural strength (BFS. Materials & methods: 930 discs, 12 mm diameter and 2 mm thick were prepared with the following variables: a. Veined (V and Plain (P PMMA. b. 5 different powder/liquid ratios by volume (1.5:1, 2:1, 2.5:1, 3:1, 3.5:1. c. Conventional (C and Injection packing methods (I. d. Dry heat (D Water bath (W; and e. different curing times. The discs were trimmed and stored in 37°C tap water for 50 hours before carrying out BFS test, according to BS EN ISO 1567: 2001. BFS test was carried out using a tensile-testing machine (Lloyd LRX, Lloyd instruments Ltd (Figure.1 b, with a x-head speed of 1mm/min. ONE-WAY ANOVA analysis and TUKEY’S comparison were carried out (MINITAB. The temperature within the curing baths and inside of curing resin was evaluated by using a thermocouple. Results: BFS of Powder/liquid ratio of 1.5:1 is significantly lower than the other four ratios. Among the last four ratios, 2.5:1 was the strongest one although the difference was not significant. BFS of the plain type of PMMA is significantly higher than the veined type.• BFS of conventionally packed PMMA discs was greater than the injectional packed ones and the difference is significant. Water bath cured resin showed a significant higher BFS compared with dry heat curing. • Changing the curing time in the dry heat bath from 7h @ 75º C and 2hrs @ 95º C to 5hrs @ 75º C and 3hrs @ 95º C and then 2hrs @ 95º C improves BFS of PMMA. In the water bath the trend is identical

  2. Comparison of two cleansing pastes for the removal of biofilm from dentures and palatal lesions in patients with atrophic chronic candidiasis.

    Science.gov (United States)

    Andrucioli, Marcela Cristina Damião; de Macedo, Leandro Dorigan; Panzeri, Heitor; Lara, Elza Helena Guimarães; Paranhos, Helena de Freitas Oliveira

    2004-01-01

    The efficacy of 2 oral hygiene products, an experimental toothpaste specific for complete denture cleansing and a regular standard toothpaste, was compared in terms of denture biofilm removal and cure of palatal lesions in patients with atrophic chronic candidiasis. The degree of correlation between presence of biofilm and mucosa erythema was also evaluated. Twenty-four complete denture wearers (45-80 years old) were divided into 2 groups: experimental paste and standard toothpaste (Sorriso-Kolynos, Brazil). Both groups received soft toothbrushes. The internal surfaces of upper dentures were stained using 1% sodium fluorescein and photographed at a 45 masculine angle at 0, 15, 30 and 60 days. The slides were scanned and the areas of interest (denture total area and biofilm area) were measured (Image Tool software). The degree of erythema was evaluated on slides according to the Prosthesis Tissue Index. There was a significant reduction (1%) in the degree of biofilm (ANOVA/Tukey) between the two initial visits (0 and 15 days) and the two final visits (30 and 60 days), and in the average erythema scores (Kruskal-Wallis) between 0 and 60 days, in both groups. The Mann-Whitney test showed a significant difference (1%) between pastes in terms of biofilm degree, but no difference was found for the erythema score. Correlation values between biofilm and erythema degree were 0.3801 (experimental paste) and (0.3678 (standard toothpaste). We may therefore conclude that the experimental product was efficient for the removal of denture plaque biofilm.

  3. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Science.gov (United States)

    2010-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a...

  4. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-02-18

    Feb 18, 2009 ... Dual Component Removable Partial Denture (DuCo RPD) is composed of a double base; lower and upper. ... periodontitis, and tooth decay etc, is a disease that leads ..... SRPD did not lead to negative effects in body weight,.

  5. Effects of Rosmarinus officinalis essential oil on germ tube formation by Candida albicans isolated from denture wearers

    Directory of Open Access Journals (Sweden)

    Lurdete Maria Rocha Gauch

    2014-06-01

    Full Text Available Introduction The aim of this study was to investigate the effects of Rosmarinus officinalis essential oil on germ tube formation by Candida albicans isolated from denture wearers. Methods Ten C. albicans isolates recovered from denture wearers were tested using 10% fetal bovine serum with or without 4% R. officinalis essential oil. Results The essential oil from R. officinalis completely inhibited germ tube formation in the investigated C. albicans isolates. Conclusions The results demonstrate that the essential oil of R. officinalis modulates C. albicans pathogenicity through its primary virulence factor (i.e., germ tube formation was suppressed.

  6. Computer-printer denture microlabeling system.

    Science.gov (United States)

    Ling, B C

    1998-03-01

    This procedure is easy to use and is cost-effective because it uses equipment that exist in any office or institution. The material used, transparency film for use with plain paper copier, is less expensive than either photographic slide film or normal slide films. Moreover, the transparency sheet can be used again for photocopying until the sheet is fully used up. There is no added cost of development of film, or is it necessary to wait for the whole roll of film to be used before the label can be retrieved and used. The background of the label is clear and only the black images of the characters of the label can be clearly seen. The effect of the transparency film, photocopy ink, and adhesive glue is not known. But no adverse effects have been noted. Microlabels have advantages over conventional labels with characters in font size 8 to 12, because more information, such as the full name of the patient, sex, country of origin, and national identification number can be incorporated. With more detailed information, quick identification of a deceased person can be made. Microlabels with a clear background will have minimal esthetic impact on the patient. The disadvantages of the technique is that it may not withstand a fire. In situations where the deceased body is badly burned, the denture and its identification strip may be burned, too. However, this risk can be minimized by placing the strip in the most posterior part of the denture-palatal in the maxillary denture and distal lingual in the mandibular denture. For testing of durability, dentures with the labels were placed in water for up to 4 months. The labels showed no sign of fading or deterioration.

  7. A case of congenital absence of numerous primary teeth treated with a denture for deciduous teeth

    OpenAIRE

    向井, 綾子; MUKAI, AYAKO

    2015-01-01

    Anomalies of the number of teeth include anodontia. The congenital absence of all teeth is called complete anodontia, and that of several teeth is called partial anodontia. Agenesis of numerous teeth causes a decrease in mastication and esthetic problems, and its treatment is often difficult.In the present paper, we report the case of a partial anodontia patient congenitally missing 6 primary teeth and some permanent teeth. The patient was treated using a denture for deciduous teeth to improv...

  8. Satisfying esthetic demands with rotational path partial dentures.

    Science.gov (United States)

    Jacobson, T E

    1982-09-01

    A description of the rotational path design concept for removable partial dentures has been presented. Through the combined efforts of the clinician and laboratory technician, a rotational path partial denture can be developed that meets the basic mechanical requirements and eliminates certain clasp arms. The primary advantages of this design include less display of metal, enhancing the patient's appearance, and decreased tooth and tissue coverage by partial denture framework components.

  9. Effect of surface treatments on shear bond strength of denture teeth to denture base resins

    Directory of Open Access Journals (Sweden)

    Farideh Bahrani

    2014-01-01

    Full Text Available Background: Debonding of denture teeth from denture bases is the most common failure in removable dentures. The purpose of this study was to evaluate the effect of surface treatments on shear bond strength of denture teeth to heat-polymerized and autopolymerized denture base resins. Materials and Methods: In this experimental in vitro study, 60 maxillary central incisor acrylic teeth were divided into two groups. Group M was polymerized with heat-polymerized acrylic resin (Meliodent by compression molding technique and group F was processed by autopolymerized acrylic resin (Futura Gen by injection molding technique. Within each group, specimens were divided into three subgroups according to the teeth surface treatments (n = 10: (1 ground surface as the control group (M 1 and F 1 , (2 ground surface combined with monomer application (M 2 and F 2 , and (3 airborne particle abrasion by 50 μm Al 2 O 3 (M 3 and F 3 . The shear bond strengths of the specimens were tested by universal testing machine with crosshead speed of 5 mm/min. Data were analyzed by two-way analysis of variance (ANOVA and Tukey′s honestly significant difference (HSD tests (P < 0.05. Results: The mean shear bond strengths of the studied groups were 96.40 ± 14.01, 124.70 ± 15.64, and 118 ± 16.38 N for M 1 , M 2 , and M 3 and 87.90 ± 13.48, 117 ± 13.88, and 109.70 ± 13.78 N for F 1 , F 2 , and F 3 , respectively. The surface treatment of the denture teeth significantly affected their shear bond strengths to the both the denture base resins (P < 0.001. However, there were no significant differences between the groups treated by monomer or airborne particle abrasion (P = 0.29. The highest percentage of failure mode was mixed in Meliodent and adhesive in Futura Gen. Conclusion: Monomer application and airborne particle abrasion of the ridge lap area of the denture teeth improved their shear bond strengths to the denture base resins regardless of the type of polymerization.

  10. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study

    Science.gov (United States)

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-01-01

    Background: The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. Materials and Methods: The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey’s post-hoc test were used for statistical analysis. Results: Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Conclusions: Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively. PMID:26124604

  11. Liquid supported denture-management of flabby ridges

    Directory of Open Access Journals (Sweden)

    Pranav V Mody

    2012-01-01

    Full Text Available The ideal properties of a denture are adequate rigidity on polished surface to bear masticatory forces and at the same time, flexibility and softness on the tissue surface for proper and even distribution of masticatory forces. The problem with conventional denture is rigidity of tissue surface; leads to uneven distribution of load. This drawback even worsens in the case of flabby, atrophic and unemployed ridges with excessive bone resorption.The liquid supported denture allows continued adaptation and eliminates the disadvantages of denture designs based on the application of temporary tissue conditioners or soft liners.

  12. Controlling fungal biofilms with functional drug delivery denture biomaterials.

    Science.gov (United States)

    Wen, Jianchuan; Jiang, Fuguang; Yeh, Chih-Ko; Sun, Yuyu

    2016-04-01

    Candida-associated denture stomatitis (CADS), caused by colonization and biofilm-formation of Candida species on denture surfaces, is a significant clinical concern. We show here that modification of conventional denture materials with functional groups can significantly increase drug binding capacity and control drug release rate of the resulting denture materials for potentially managing CADS. In our approach, poly(methyl methacrylate) (PMMA)-based denture resins were surface grafted with three kinds of polymers, poly(1-vinyl-2-pyrrolidinone) (PNVP), poly(methacrylic acid) (PMAA), and poly(2-hydroxyethyl methacrylate) (PHEMA), through plasma-initiated grafting polymerization. With a grafting yield as low as 2 wt%, the three classes of new functionalized denture materials showed significantly higher drug binding capacities toward miconazole, a widely used antifungal drug, than the original PMMA denture resin control, leading to sustained drug release and potent biofilm-controlling effects against Candida. Among the three classes of functionalized denture materials, PNVP-grafted resin provided the highest miconazole binding capability and the most powerful antifungal and biofilm-controlling activities. Drug binding mechanisms were studied. These results demonstrated the importance of specific interactions between drug molecules and functional groups on biomaterials, shedding lights on future design of CADS-managing denture materials and other related devices for controlled drug delivery.

  13. Denture bar-coding: An innovative technique in forensic dentistry

    Science.gov (United States)

    Dineshshankar, Janardhanam; Venkateshwaran, Rajendran; Vidhya, J.; Anuradha, R.; Mary, Gold Pealin; Pradeep, R.; Senthileagappan, A. R.

    2015-01-01

    Denture markers play an important role in forensic odontology and also in identifying a person. A number of methods are there for identifying dentures from a less expensive technique to a more expensive technique. Out of different denture markers, the bar-coding system is a way of collecting data from the mobile. Even a huge amount of data can be stored in that. It can be easily incorporated during acrylization of the denture and thus could be helpful in identification. This article reviews the strengths of bar-coding and how easily it can be used in the routine procedure. PMID:26538876

  14. Denture bar-coding: An innovative technique in forensic dentistry.

    Science.gov (United States)

    Dineshshankar, Janardhanam; Venkateshwaran, Rajendran; Vidhya, J; Anuradha, R; Mary, Gold Pealin; Pradeep, R; Senthileagappan, A R

    2015-08-01

    Denture markers play an important role in forensic odontology and also in identifying a person. A number of methods are there for identifying dentures from a less expensive technique to a more expensive technique. Out of different denture markers, the bar-coding system is a way of collecting data from the mobile. Even a huge amount of data can be stored in that. It can be easily incorporated during acrylization of the denture and thus could be helpful in identification. This article reviews the strengths of bar-coding and how easily it can be used in the routine procedure.

  15. The social solution-denture esthetics, phonetics, and function.

    Science.gov (United States)

    Roumanas, Eleni D

    2009-02-01

    Tooth loss and rehabilitation with dentures can have tremendous patient impact and social implications. In an image-conscious society, dentures restore a sense of normalcy and allow the patient the ability to interact with others. The most frequent denture complaints include chewing discomfort and objectionable esthetics and phonetics. Determining patient expectations and their influence on patient satisfaction with treatment is critical. Current evidence on functional outcomes, patient satisfaction, and cost-effectiveness of treatment with conventional dentures versus implants are important factors to consider during treatment planning for the edentulous patient. The purpose of this article is to review some exemplar literature for the successful treatment of the edentulous patient.

  16. Clinical and Histological Findings of Denture Stomatitis as Related to Intraoral Colonization Patterns of C. albicans, Salivary Flow, and Dry Mouth

    Science.gov (United States)

    AlTarawneh, Sandra; Bencharit, Sompop; Mendoza, Luisito; Curran, Alice; Barrow, David; Barros, Silvana; Preisser, John; Loewy, Zvi G.; Gendreau, Linda; Offenbacher, Steven

    2012-01-01

    Purpose Multifactorial etiological factors contribute to denture stomatitis (DS), a type of oral candidiasis; however, unlike other oral candidiasis, DS can occur in a healthy person wearing a denture. In this study, we therefore attempt to explore the association between candida, denture, and mucosal tissue using 1) exfoliative cytology, 2) the candidal levels present in saliva, on mucosal tissues and on denture surfaces, and 3) the salivary flow rate and xerostomic symptoms. Materials and Methods A cross-sectional study enrolled 32 edentulous participants, 17 without DS as controls and 15 with DS (Newton’s classification type II and III). Participants with systemic or other known oral conditions were excluded. Participants completed a xerostomia questionnaire, and salivary flow rates were measured. Samples of unstimulated whole saliva (UWS) and stimulated whole saliva (SWS) were collected. UWS was used for fungal culturing. Periodic acid-Schiff (PAS) stain and quantitative exfoliative cytology were performed on samples from affected and unaffected mucosa from each participant. Levels of Candida species (albicans and non-albicans) were determined in salivary samples (expressed as colony-forming units, CFU), as well as from swab samples obtained from denture fitting surfaces, in addition to affected and unaffected mucosa. Results There were no significant differences in salivary flow rates, mucosal wetness, or frequency of reported dry mouth comparing participants with and without DS. Exfoliative cytology of mucosal smears demonstrated significantly higher (P = 0.02) inflammatory cell counts in DS patients, as compared with smears of healthy denture-wearers. C. albicans was significantly more prevalent in saliva (P = 0.03) and on denture surfaces (P = 0.002) of DS participants, whereas mucosal candidal counts and the presence of cytological hyphae did not show significant difference comparing DS to healthy participants. Conclusions In this investigation, we

  17. Improvised Neutral Zone Technique in a Completely Edentulous Patient with an Atrophic Mandibular Ridge and Neuromuscular Incoordination: A Clinical Tip.

    Science.gov (United States)

    Saravanakumar, Prathibha; Thirumalai Thangarajan, Saravanan; Mani, Umamaheswari; Kumar V, Anand

    2017-04-24

    Resorption of mandibular ridges is a multifactorial and biomechanical disease that is chronic, progressive, irreversible, and cumulative leading to loss of sulcular depth, vertical dimension loss, and decreased lower facial height. Some common neurological, hormonal, and metabolic disorders affect the adaptability of dentures, and this can be diagnosed by a trained prosthodontist with proper history-taking and clinical examination.The denture becomes passive due to complex neuromuscular control and causes difficulties in impression-making, mastication, and swallowing, which in turn leads to loss of retention and stability in complete dentures. Hence, residual ridge resorption becomes a challenging scenario for a clinician during fabrication of complete dentures. The neutral zone concept plays a significant role in overcoming these challenges. The neutral zone is the area where the outward forces from the tongue are neutralized or nullified by the forces of the lips and cheeks acting inward during functional movements.The neutral zone technique is an alternative approach for the construction of lower complete dentures. It is most effective for dentures where there is a highly atrophic ridge and history of denture instability. The technique aims to construct a denture that is shaped by muscle function and is in harmony with the surrounding oral structures. The technique is by no means new, but it is a valuable one. It is rarely used because of the extra clinical step involved and its complexity. Complete and partial denture failures are often related to non-compliance with neutral zone factors. Thus, the evaluation of the neutral zone is an important factor. Increased retention and stability with reduced chairside time are the salient features of this new approach to any clinically challenging situation in complete dentures.This clinical report describes a modification of the conventional neutral zone technique using improvised procedures to minimize chairside

  18. Development of a contemporary animal model of Candida albicans-associated denture stomatitis using a novel intraoral denture system.

    Science.gov (United States)

    Johnson, Clorinda C; Yu, Alika; Lee, Heeje; Fidel, Paul L; Noverr, Mairi C

    2012-05-01

    Denture stomatitis (DS) is a fungal infection characterized by inflammation of the oral mucosa in direct contact with the denture and affects up to 50% of denture wearers. Despite the prevalence, very little is known about the role of fungal or host factors that contribute to pathogenesis. Recently, we developed a novel intraoral denture system for rodent research. This denture system consists of custom-fitted fixed and removable parts to allow repeated sampling and longitudinal studies. The purpose of this study was to use this denture system to develop a clinically relevant animal model of DS. To establish DS, rats were inoculated with pelleted Candida albicans, which resulted in sustained colonization of the denture and palate for 8 weeks postinoculation. Biofilm formation on the denture was observed by week 4 and on the palate by week 6 postinoculation. Rats were monitored for clinical signs of disease by assigning a clinical score after macroscopic examination of the palate tissue according to Newton's method. By week 4 postinoculation, the majority of inoculated rats with dentures exhibited a clinical score of 1 (pinpoint erythema). By week 6 and week 8 postinoculation, increasing percentages of rats exhibited a clinical score of 2 (diffuse erythema/edema). Histological analysis of palate tissue demonstrated progressively increasing inflammatory cell recruitment throughout the time course of the infection. Palatal biofilm formation was commensurate with development of palatal erythema, which suggests a role for biofilm in the inflammatory response.

  19. Relation between Clinical Oral Dryness Score and Denture Satisfaction among Patients’ in a Tertiary Care Centre, India

    Science.gov (United States)

    Vundavalli, Sudhakar; Rao, A. Kaleswara; Vadapalli, Sriharsha babu; Rao, Duggineni Chalapathi; thabusum, Ayesha

    2017-01-01

    Introduction Xerostomia is a subjective feeling of dryness commonly seen in elderly populations which impairs the quality of life. Due to loss of lubricating property of saliva the buccal mucosa, tongue and lips tend to stick leading to dry, freckled, ulcerated and sore mucosa which is of major concern to the patient to use complete denture. Aim The aim of the study was to assess the relation between oral dryness score and denture satisfaction among elderly patients. Materials and Methods A cross-sectional study was conducted in prosthodontics department of a dental institution. Patients wearing dentures for at least six months were invited to participate in study. Visual Analogue Scale (VAS) with scores ranging from 0-100 was used to assess patient’s satisfaction and clinical oral dryness score was assessed using the criteria described by Osailan SM et al., with scores ranging from 0-10. Data was analysed with SPSS software (version-20) and Kendall’s tau-b correlation was used to determine the relationship between mean denture satisfactions and mean clinical oral dryness scores. Results A total of 220 participants were included in the study based on inclusion criteria. Mean dryness score of the participants was 1.8±0.6 and mean VAS-score for denture satisfaction was 74.32±21.20 for aesthetics, for chewing ability the mean score was 62.31±19.64 and for phonetics it was 67.82±30.60. Strong negative correlation between VAS-scores and oral dryness scores was observed. Conclusion Clinical oral dryness score is one of the important factors which influence denture satisfaction. Dentist should consider in predicting prognosis. PMID:28658910

  20. Relation between Clinical Oral Dryness Score and Denture Satisfaction among Patients' in a Tertiary Care Centre, India.

    Science.gov (United States)

    Doppalapudi, Radhika; Vundavalli, Sudhakar; Rao, A Kaleswara; Vadapalli, Sriharsha Babu; Rao, Duggineni Chalapathi; Thabusum, Ayesha

    2017-05-01

    Xerostomia is a subjective feeling of dryness commonly seen in elderly populations which impairs the quality of life. Due to loss of lubricating property of saliva the buccal mucosa, tongue and lips tend to stick leading to dry, freckled, ulcerated and sore mucosa which is of major concern to the patient to use complete denture. The aim of the study was to assess the relation between oral dryness score and denture satisfaction among elderly patients. A cross-sectional study was conducted in prosthodontics department of a dental institution. Patients wearing dentures for at least six months were invited to participate in study. Visual Analogue Scale (VAS) with scores ranging from 0-100 was used to assess patient's satisfaction and clinical oral dryness score was assessed using the criteria described by Osailan SM et al., with scores ranging from 0-10. Data was analysed with SPSS software (version-20) and Kendall's tau-b correlation was used to determine the relationship between mean denture satisfactions and mean clinical oral dryness scores. A total of 220 participants were included in the study based on inclusion criteria. Mean dryness score of the participants was 1.8±0.6 and mean VAS-score for denture satisfaction was 74.32±21.20 for aesthetics, for chewing ability the mean score was 62.31±19.64 and for phonetics it was 67.82±30.60. Strong negative correlation between VAS-scores and oral dryness scores was observed. Clinical oral dryness score is one of the important factors which influence denture satisfaction. Dentist should consider in predicting prognosis.

  1. Evaluation of senior Brazilian dental students about mouth preparation and removable partial denture design.

    Science.gov (United States)

    Neto, Arcelino Farias; Duarte, Antônio Ricardo Calazans; Shiratori, Fábio Kenji; de Alencar e Silva Leite, Pedro Henrique; Rizzatti-Barbosa, Célia Marisa; Bonachela, Wellington Cardoso

    2010-11-01

    This study aimed to evaluate the knowledge of senior dental students about mouth preparation and removable partial denture (RPD) design. Two hundred sixty-six senior students from eleven dental schools in the State of São Paulo, Brazil, comprised the sample. The subjects examined two partially edentulous casts mounted on a semiadjustable articulator, answered a questionnaire regarding the treatment plan, and drew the RPD design. The casts consisted of Kennedy Class III, modification 1 maxillary arch and Class II mandibular arch. Ninety percent of the students believed that mouth preparation should be performed although no one was able to name all necessary procedures. For the maxillary arch, 12 percent of the denture designs were completely appropriate, 51 percent were partially appropriate, and 37 percent were inappropriate. For the mandibular arch, the results were 3 percent, 40 percent, and 57 percent, respectively.

  2. Dimensional accuracy of acrylic resin maxillary denture base polymerized by a new injection pressing method.

    Science.gov (United States)

    Ono, Takahiro; Kita, Seiichi; Nokubi, Takashi

    2004-09-01

    The purpose of this study was to confirm the dimensional accuracy of a newly developed injection pressing method for resin polymerization by making use of the internal electric resistance of resin to determine the optimal timing for resin injection. A new injection pressing polymerization pot with a built-in system to measure the internal electric resistance of resin was used for resin polymerization. Fluid-type resin was injected into the mold of a maxillary complete denture base under nine different conditions: three different timings for resin injection according to the electric resistance of resin dough (early stage: 11 Mohms; intermediate stage: 16 Mohms; final stage: 21 Mohms) and three different motor powers for resin injection (2000 N, 4000 N, and 6000 N). In the best polymerization condition (injected during the early stage of resin dough under a motor power of 6000 N), the adaptation of the denture base showed a statistically significant improvement compared with the conventional pouring method.

  3. 21 CFR 872.3760 - Denture relining, repairing, or rebasing resin.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3760 Denture relining... device composed of materials such as methylmethacrylate, intended to reline a denture surface that contacts tissue, to repair a fractured denture, or to form a new denture base. This device is not...

  4. 21 CFR 872.3540 - OTC denture cushion or pad.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3540 OTC denture cushion or pad. (a...-counter. (b) Classification. (1) Class I if the device is made of wax-impregnated cotton cloth that the... denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the...

  5. 21 CFR 872.3520 - OTC denture cleanser.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3520 OTC denture cleanser. (a) Identification. An OTC denture cleanser is a device that consists of material in the form of a powder, tablet, or paste that is intended to remove debris from removable prosthetic dental appliances, such as bridges...

  6. The "Amex" cast aluminum denture of World War I.

    Science.gov (United States)

    Hyson, J M; Whitehorne, J W

    2001-07-01

    In 1917-18, the U.S. Army revived a denture technique first introduced in 1866 by Dr. James Baxter Bean, the Confederate dental surgeon who established the first military maxillofacial hospital trauma ward in Atlanta, Georgia, during the American Civil War--the cast aluminum wartime denture.

  7. [Serious complications following removal of an ingested partial denture

    NARCIS (Netherlands)

    Ruiter, M.H. de; Damme, P.A. van; Drenth, J.P.H.

    2007-01-01

    Complications occurred in a 41-year-old woman following an attempt to remove a partial denture by oesophagoscopy. These were: laceration of the oesophagus with subsequent mediastinitis, pneumothorax, and pneumopericardium. At a second oesophagoscopy the denture was removed from the oesophagus using

  8. [Serious complications following (removal after) ingestion of a partial denture

    NARCIS (Netherlands)

    Ruiter, M.H. de; Damme, P.A. van; Drenth, J.P.H.

    2008-01-01

    Complications occurred in a 41-year-old woman (case 1) following a first attempt to remove a partial denture by oesophagoscopy. These were: laceration of the oesophagus with subsequent mediastinitis, pneumothorax, and pneumopericardium. With a second oesophagoscopy the denture was removed from the o

  9. New clinical technique for fabrication immediate partial denture

    Directory of Open Access Journals (Sweden)

    Abdulsalam Ali Zwiad

    2013-01-01

    Full Text Available Immediate partial denture is a choice of treatment due to various cases of teeth extraction such as badly carious teeth, periodontal disease, eruption problems, trauma, and other reasons. Many choices are used to replace the lost teeth; one of these choices is a removable plastic denture in which hot cured acrylic resin should be used to fabricate such denture. Aim of Study: To provide an applicable technique to fabricate an immediate partial denture by reducing and declining the prosthetic steps and some materials in proportional to the conventional method. Clinical Procedures: Maxillary and mandibular stone casts are mounted to a simple articulator and the procedures are explained as step by step to fabricate an immediate partial denture without using the conventional methods and material, just using a small quantity of white cold cure acrylic resin to fabricate the artificial teeth, hot cure acrylic resin for the denture base and mold made of a silicon impression material are used to fabricate an immediate partial denture. Conclusion: The finished immediate partial denture showed a good retention and produced the exact shapes and sizes of the extracted teeth with low cost and less time for a dentist and patient.

  10. A Comparative Study of Heat and Self-Cured Acrylic Resins on Color Stability of 5 Brands of Denture Teeth

    Directory of Open Access Journals (Sweden)

    Vafaee

    2016-03-01

    Full Text Available Background Denture teeth play a critical role in overall aesthetic outcomes of removable complete dentures, and long-term maintenance of these outcomes depends on the color stability of the prosthetic teeth. The characteristics of denture base resins play a significant role in prosthetic clinical performance and aesthetics. Objectives The purpose of this study was to assess the effect of two flasking materials on the color stability of five brands of denture teeth that were immersed in commonly consumed beverages. Materials and Methods In the present study 560 denture teeth (20 series were invested with heat- and cold-cured acrylic resin. All the specimens were thermo cycled between 4°C and 60°C, with 60 Seconds dwell times for 1000 cycles. Subsequently, the specimens in each group were divided into four subgroups based on the immersion medium: coffee, tea, cola, or distilled water. Digital images of the teeth were taken before immersion and 30 days after immersion. The color samples were measured using the CIE L* a* b* system, and color differences (ΔE were calculated. The data were evaluated by 3-way ANOVA and the Tukey HSD test. Results There were significant differences in color change between the cold-cured acrylic resins and the heat-cured acrylic resins, with a reduced amount of discoloration in the heat-cured group (ΔE = 10.12 ± 3.93, P = 0.001. The solutions showed significantly different amounts of discoloration on the teeth; distilled water had the least effect (ΔE = 8.49 ± 2.62, P = 0.001 and coffee had the maximum discoloration (ΔE = 14.14 ± 7.77, P = 0.001. A Tukey test showed that there was no significant difference between each brand of denture teeth. Conclusions Coffee caused the most color changes in the examined resin denture teeth. Tea and cola left less staining on the teeth, and distilled water caused the least discoloration. Generally, investing by heat- and cold-cured acrylic resins can significantly affect the

  11. Prolonged Impacted Denture in the Esophagus: A Case Report and

    Directory of Open Access Journals (Sweden)

    Gulzar Ahmad Dar

    2015-01-01

    Full Text Available Foreign body ingestion and aspiration is among the most common causes of emergency department visit associated with high morbidity and mortality. Ingested and aspirated denture is rare conditions being scarcely reported in the literature. We herein report a 57-year-old man who presented with 2-day history of liquid and solid dysphagia who was diagnosed to have impacted denture in esophagus since 3 years prior to presentation. He was diagnosed to have esophagus adenocarcinoma and had undergone esophageal radiotherapy. The denture was removed successfully using esophagoscopy and the patient was discharged after 48-hour care with good condition. To prevent accidental ingestion, dentures should be made to fit properly. Damaged or malfitting dentures should be discarded and replaced. Patients should be strongly advised against wearing them during sleep-time.

  12. Imaging findings of swallowed dentures: a case series.

    Science.gov (United States)

    Chawla, Ashish; Bosco, Jerome; Subramanian, Manickam; Chokkapan, Kabilan; Shenoy, Jagadish; Lim, Tze Chwan

    2015-12-01

    Dental prosthesis is an uncommon ingested non-food foreign body in adults. Once swallowed, it can lead to serious complications and morbidity. Hence, early localization of the offending foreign body is crucial for timely management. As the dentures are usually made up of non-metallic material and often impacted at or below the level of C7 vertebra, conventional radiograph has limited role in their evaluation. We describe the clinical history and imaging findings of swallowed partial dentures in four patients who presented to the emergency department. The dentures were localized using unenhanced CT of the neck that showed the characteristic mildly hyperdense curvilinear or irregular appearance of the dentures within the upper esophagus. Multiplanar CT reconstructions provide an orientation of the ingested denture within the esophagus, thus guiding the endoscopist.

  13. Contemporary methods and mobile denture cleansers and theirs significance for older population

    Directory of Open Access Journals (Sweden)

    Strajnić Ljiljana

    2011-01-01

    Full Text Available Introduction. A dramatic increase in the number of people living in their seventies, eighties and nineties is associated with a loss of teeth and the use of mobile dentures. The aim of this paper was to highlight the consequences of poor denture hygiene on oral and general health in vulnerable elderly people, in long-term hospitalized elderly patients and in long-term institutionalized elderly in nursing homes. Denture deposits and consequences of poor denture hygiene. The number of bacteria living in the mouth is getting larger after putting denture on. Namely, a small ”space” develops between jaw and denture, creating perfect conditions for bacterial growth. Denture becomes a ”reservoir” of micro-organisms. Denture deposits such as bacterial plaque, fungi, tartar and remnants could be responsible for: stomatitis prothetica, cheilitis angularis, inflammatory fibrous hyperplasia, halitosis (bad breath, dental caries in mobile denture carriers, mucositis and periimplantitis in mobile implant over-dentures carriers, accelerated destruction of denture materials for underlying, such as denture base soft liners, respiratory airways diseases, bacterial endocarditis and gastrointestinal infections. Removal of denture deposits. It is recommendable to combine mechanical and chemical denture cleaning. Denture submersion into a commercial cleansing solution for less than one hour is an effective cleaning method. Commercial cleansers specifically intended for dentures with metal parts should be used for those dentures. Commercial cleansers with a new component of silicon polymer, whose thin layer surrounds all denture surfaces and disables oral bacteria to agglomerate, are effective and useful. Preventive hygienic treatments are very important in hospitals and homes for the aged, bearing in mind that old and ill persons reside here. Those institutions are recommended to get equipped with ultrasound denture cleaners. Importance of written brochure on

  14. A Case Report for a Complex Denture Case on a Special Care Patient with Osteogenesis Imperfecta.

    Science.gov (United States)

    Sawyer, Colin; Drysdale, David

    2015-05-01

    This case report presents a patient with Dentogenesis Imperfecta (DI) associated with Osteogenesis Imperfecta (OI) and its subsequent dental manifestations. The patient in this report (see Figure 1) has spent his life living with his disability type III OI (also known as brittle bone disease) and its degenerative affects. The patient is independent and enjoys his social life but felt his existing dentures were having an adverse effect on the quality of his life. The patient attended Dorset County Hospitals Special Care Dentistry and on clinical examination it was noted the patient was partially dentate with a class III malocclusion and brownish discoloration of the remaining teeth caused by enamel hypoplasia. Treatment for this patient would entail making a maxillary complete denture and a mandibular partial chrome denture, normally quite simple tasks but due to the DI and its dental manifestations, the treatment would be complicated. This case demonstrates how a complex case treated by a collaborative dental team using their different skills and knowledge can lead to a successful and rewarding treatment for both patient and team.

  15. Veterans Administration Cooperative Dental Implant Study--comparisons between fixed partial dentures supported by blade-vent implants and removable partial dentures. Part I: Methodology and comparisons between treatment groups at baseline.

    Science.gov (United States)

    Kapur, K K

    1987-10-01

    This study was conducted to determine whether fixed partial dentures supported by dental implants provide an acceptable alternative to conventional removable partial dentures in patients with Kennedy class I or class II edentulous conditions. The acceptability of the new treatment will be based on success rates, impact on the health of the remaining dentition, masticatory performance, patient satisfaction, and maintenance care and cost. The study was planned also to provide comparisons between two designs commonly used by dentists for fabricating removable partial dentures. The designs differed only in terms of the type of the retainer (clasp type) and tooth support (rest location). A total of 272 patients with Kennedy class I and class II edentulous conditions were assigned on a random basis to one of the treatment groups, 134 to receive a removable partial denture and 138 a fixed partial denture supported by a blade-vent implant. All of the patients were medically screened and met prespecified criteria for oral hygiene, bone support for abutment teeth, and size of the residual ridge. Thirty-four patients were eliminated from the study before completion of their treatment. An additional six patients with early implant failures were reentered in the study and followed up as a separate group. The remaining 232 patients received comprehensive dental care, including removable partial dentures for 118 and fixed partial dentures for 114 patients. A series of examinations, radiographs, masticatory performance tests, patient satisfaction, food selection questionnaires, and dietary history were completed before initiation of the treatment, 16 weeks after the insertion of an RPD or an implant, and thereafter at 6-, 18-, 36-, and 60-month intervals. In addition, patients were seen at 6-month intervals for a recall dental examination, oral prophylaxis, plaque instructions, radiographic survey of the implant, and any needed dental treatment. The randomization stratification

  16. Effect of different denture cleansers on surface roughness and microhardness of artificial denture teeth

    Science.gov (United States)

    Yuzugullu, Bulem; Cetinsahin, Cem; Celik, Cigdem

    2016-01-01

    PURPOSE The aim of this study was to compare the effects of different denture cleansers on the surface roughness and microhardness of various types of posterior denture teeth. MATERIALS AND METHODS 168 artificial tooth specimens were divided into the following four subgroups (n=42): SR Orthotyp PE (polymethylmethacrylate); SR Orthosit PE (Isosit); SR Postaris DCL (double cross-linked); and SR Phonares II (nanohybrid composite). The specimens were further divided according to the type of the denture cleanser (Corega Tabs (sodium perborate), sodium hypochlorite (NaOCl), and distilled water (control) (n=14)) and immersed in the cleanser to simulate a 180-day immersion period, after which the surface roughness and microhardness were tested. The data were analyzed using the Kruskal–Wallis test, Conover's nonparametric multiple comparison test, and Spearman's rank correlation analysis (P<.05). RESULTS A comparison among the denture cleanser groups showed that NaOCl caused significantly higher roughness values on SR Orthotyp PE specimens when compared with the other artificial teeth (P<.001). Furthermore, Corega Tabs resulted in higher microhardness values in SR Orthotyp PE specimens than distilled water and NaOCl (P<.005). The microhardness values decreased significantly from distilled water, NaOCl, to Corega Tabs for SR Orthosit PE specimens (P<.001). SR Postaris DLC specimens showed increased microhardness when immersed in distilled water or NaOCl when compared with immersion in Corega Tabs (P<.003). No correlation was found between surface roughness and microhardness (r=0.104, P=.178). CONCLUSION NaOCl and Corega Tabs affected the surface roughness and microhardness of all artificial denture teeth except for the new generation nanohybrid composite teeth. PMID:27826382

  17. COMPARISON OF BOND STRENGTH OF THREE DENTURE TEETH MADE IN IRAN WITH RESIN BASES AND IVOCLAR DENTURE TEETH

    Directory of Open Access Journals (Sweden)

    R MOSHARRAF

    2002-09-01

    Full Text Available Introduction. One of the most common repairs in removable prostheses is, substitution debonded teeth in their places. In the other hand, with the incrased use of implants & the commensurate increase in force applied to prosthetic components, it is probable that tooth debonding will become an even greater clinical problem. Therefore in this study we are trying to select the strongest bond strength of Iranian denture teeth with respect to lvoclar denture teeth (Approved and recommended by ADA. Methods. In this study the upper anterior set of three Iranian denture teeth (called Berelian, Marjan and Supernevoclar and lvoclar denture teeth were used. of each type of denture teeth, 21 specimens was selected and the denture teeth glaze was removed in each specimen. Then the laboratory procedures (removal of wax & resin packing according to British Standard 3990 (BS 3990 or ISO 3336 was done. Each specimen was tested by an Instron machine. The tensile test used with the cross-head speed of 5mm/min until fracture occured. Results. The mean bond strength in Berelian teeth uppermost, afterward Marjan, Ivoclar and Super nevoclared in second, third and fourh rank respectively. But statistical analysis showed no significanrt difference among the mean bond strength in four groups of denture teeth. The percentage of cohesive fracture (sum of acrylic farcture and dental fracture in Berelian specimens was uppermost, afterward Supernevoclar and Marjan were placed in second, third & fourth rank respectively. But statistical analysis showed no significant difference among the percentage of cohesive fracture in different groups of denture teeth. Discussion. The bond strength and the percentage of cohesive fracture of Iranian denture teeth is the same & competitive to lvoclar denture teeth (approved and recommended by ADA.