WorldWideScience

Sample records for common test methods

  1. Advantages and limitations of common testing methods for antioxidants.

    Science.gov (United States)

    Amorati, R; Valgimigli, L

    2015-05-01

    Owing to the importance of antioxidants in the protection of both natural and man-made materials, a large variety of testing methods have been proposed and applied. These include methods based on inhibited autoxidation studies, which are better followed by monitoring the kinetics of oxygen consumption or of the formation of hydroperoxides, the primary oxidation products. Analytical determination of secondary oxidation products (e.g. carbonyl compounds) has also been used. The majority of testing methods, however, do not involve substrate autoxidation. They are based on the competitive bleaching of a probe (e.g. ORAC assay, β-carotene, crocin bleaching assays, and luminol assay), on reaction with a different probe (e.g. spin-trapping and TOSC assay), or they are indirect methods based on the reduction of persistent radicals (e.g. galvinoxyl, DPPH and TEAC assays), or of inorganic oxidizing species (e.g. FRAP, CUPRAC and Folin-Ciocalteu assays). Yet other methods are specific for preventive antioxidants. The relevance, advantages, and limitations of these methods are critically discussed, with respect to their chemistry and the mechanisms of antioxidant activity. A variety of cell-based assays have also been proposed, to investigate the biological activity of antioxidants. Their importance and critical aspects are discussed, along with arguments for the selection of the appropriate testing methods according to the different needs.

  2. Using a Linear Regression Method to Detect Outliers in IRT Common Item Equating

    Science.gov (United States)

    He, Yong; Cui, Zhongmin; Fang, Yu; Chen, Hanwei

    2013-01-01

    Common test items play an important role in equating alternate test forms under the common item nonequivalent groups design. When the item response theory (IRT) method is applied in equating, inconsistent item parameter estimates among common items can lead to large bias in equated scores. It is prudent to evaluate inconsistency in parameter…

  3. Five Common Glaucoma Tests

    Science.gov (United States)

    ... About Us Donate In This Section Five Common Glaucoma Tests en Español email Send this article to ... year or two after age 35. A Comprehensive Glaucoma Exam To be safe and accurate, five factors ...

  4. Test Anxiety, Computer-Adaptive Testing and the Common Core

    Science.gov (United States)

    Colwell, Nicole Makas

    2013-01-01

    This paper highlights the current findings and issues regarding the role of computer-adaptive testing in test anxiety. The computer-adaptive test (CAT) proposed by one of the Common Core consortia brings these issues to the forefront. Research has long indicated that test anxiety impairs student performance. More recent research indicates that…

  5. Robust Scale Transformation Methods in IRT True Score Equating under Common-Item Nonequivalent Groups Design

    Science.gov (United States)

    He, Yong

    2013-01-01

    Common test items play an important role in equating multiple test forms under the common-item nonequivalent groups design. Inconsistent item parameter estimates among common items can lead to large bias in equated scores for IRT true score equating. Current methods extensively focus on detection and elimination of outlying common items, which…

  6. Ky. Road-Tests Common Core

    Science.gov (United States)

    Ujifusa, Andrew

    2012-01-01

    Results from new state tests in Kentucky--the first in the nation explicitly tied to the Common Core State Standards--show that the share of students scoring "proficient" or better in reading and math dropped by roughly a third or more in both elementary and middle school the first year the tests were given. Kentucky in 2010 was the…

  7. Estimation of the common cause failure probabilities on the component group with mixed testing scheme

    International Nuclear Information System (INIS)

    Hwang, Meejeong; Kang, Dae Il

    2011-01-01

    Highlights: ► This paper presents a method to estimate the common cause failure probabilities on the common cause component group with mixed testing schemes. ► The CCF probabilities are dependent on the testing schemes such as staggered testing or non-staggered testing. ► There are many CCCGs with specific mixed testing schemes in real plant operation. ► Therefore, a general formula which is applicable to both alternate periodic testing scheme and train level mixed testing scheme was derived. - Abstract: This paper presents a method to estimate the common cause failure (CCF) probabilities on the common cause component group (CCCG) with mixed testing schemes such as the train level mixed testing scheme or the alternate periodic testing scheme. In the train level mixed testing scheme, the components are tested in a non-staggered way within the same train, but the components are tested in a staggered way between the trains. The alternate periodic testing scheme indicates that all components in the same CCCG are tested in a non-staggered way during the planned maintenance period, but they are tested in a staggered way during normal plant operation. Since the CCF probabilities are dependent on the testing schemes such as staggered testing or non-staggered testing, CCF estimators have two kinds of formulas in accordance with the testing schemes. Thus, there are general formulas to estimate the CCF probability on the staggered testing scheme and non-staggered testing scheme. However, in real plant operation, there are many CCCGs with specific mixed testing schemes. Recently, Barros () and Kang () proposed a CCF factor estimation method to reflect the alternate periodic testing scheme and the train level mixed testing scheme. In this paper, a general formula which is applicable to both the alternate periodic testing scheme and the train level mixed testing scheme was derived.

  8. Identification of common allergens for united airway disease by skin prick test

    Directory of Open Access Journals (Sweden)

    Vikas Deep Mishra

    2016-01-01

    Full Text Available Objective: Identification of common allergens by skin prick test in patients of united airway disease. Materials and Methods: Skin prick test was performed in 60 patients of United Airway Disease to identify the common allergens. A total of 62 allergens consisting of 36 types of pollen, 5 fungi, 4 insects, 8 type of dusts, 4 dander, 3 fabrics, Dust mite and Parthenium leaves were tested. Result: Most common allergens were Dust mite (60% followed by Parthenium leaves (45%, insects (18.75%, pollen (14.81%, dust allergens (8.51%, fabrics (8.33%, fungi (5.66%, dander (5%. Most common insect allergens were cockroach (female (30%, cockroach (male (23.33%. Common pollens were Ricinus communis (28.33%, Amaranthus spinosus (28.33%, Parthenium hysterophorus (26.66%, Eucalyptus tereticornis (26.66% and Cynodon dactylon (25%. Common dust allergens were house dust (21.66%, paper dust (11.66% and cotton mill dust (10%. Among fabrics kapok cotton (13.33% showed maximum positivity. Among fungi Aspergillus fumigatus (10% followed by A. niger (6.66% were most common. In animal dander group common ones were cat dander followed by dog dander. Conclusion: In conclusion it can be said that the knowledge drawn by above study will help to treat patients by immunotherapy or avoidance strategy.

  9. Feasibility of Combining Common Data Elements Across Studies to Test a Hypothesis.

    Science.gov (United States)

    Corwin, Elizabeth J; Moore, Shirley M; Plotsky, Andrea; Heitkemper, Margaret M; Dorsey, Susan G; Waldrop-Valverde, Drenna; Bailey, Donald E; Docherty, Sharron L; Whitney, Joanne D; Musil, Carol M; Dougherty, Cynthia M; McCloskey, Donna J; Austin, Joan K; Grady, Patricia A

    2017-05-01

    The purpose of this article is to describe the outcomes of a collaborative initiative to share data across five schools of nursing in order to evaluate the feasibility of collecting common data elements (CDEs) and developing a common data repository to test hypotheses of interest to nursing scientists. This initiative extended work already completed by the National Institute of Nursing Research CDE Working Group that successfully identified CDEs related to symptoms and self-management, with the goal of supporting more complex, reproducible, and patient-focused research. Two exemplars describing the group's efforts are presented. The first highlights a pilot study wherein data sets from various studies by the represented schools were collected retrospectively, and merging of the CDEs was attempted. The second exemplar describes the methods and results of an initiative at one school that utilized a prospective design for the collection and merging of CDEs. Methods for identifying a common symptom to be studied across schools and for collecting the data dictionaries for the related data elements are presented for the first exemplar. The processes for defining and comparing the concepts and acceptable values, and for evaluating the potential to combine and compare the data elements are also described. Presented next are the steps undertaken in the second exemplar to prospectively identify CDEs and establish the data dictionaries. Methods for common measurement and analysis strategies are included. Findings from the first exemplar indicated that without plans in place a priori to ensure the ability to combine and compare data from disparate sources, doing so retrospectively may not be possible, and as a result hypothesis testing across studies may be prohibited. Findings from the second exemplar, however, indicated that a plan developed prospectively to combine and compare data sets is feasible and conducive to merged hypothesis testing. Although challenges exist in

  10. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  11. The precision and torque production of common hip adductor squeeze tests used in elite football

    DEFF Research Database (Denmark)

    Light, N; Thorborg, K

    2016-01-01

    OBJECTIVES: Decreased hip adductor strength is a known risk factor for groin injury in footballers, with clinicians testing adductor strength in various positions and using different protocols. Understanding how reliable and how much torque different adductor squeeze tests produce will facilitate...... choosing the most appropriate method for future testing. In this study, the reliability and torque production of three common adductor squeeze tests were investigated. DESIGN: Test-retest reliability and cross-sectional comparison. METHODS: Twenty elite level footballers (16-33 years) without previous...

  12. Evaluation of clinical methods for peroneal muscle testing.

    Science.gov (United States)

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described

  13. Comparison of Suitability of the Most Common Ancient DNA Quantification Methods.

    Science.gov (United States)

    Brzobohatá, Kristýna; Drozdová, Eva; Smutný, Jiří; Zeman, Tomáš; Beňuš, Radoslav

    2017-04-01

    Ancient DNA (aDNA) extracted from historical bones is damaged and fragmented into short segments, present in low quantity, and usually copurified with microbial DNA. A wide range of DNA quantification methods are available. The aim of this study was to compare the five most common DNA quantification methods for aDNA. Quantification methods were tested on DNA extracted from skeletal material originating from an early medieval burial site. The tested methods included ultraviolet (UV) absorbance, real-time quantitative polymerase chain reaction (qPCR) based on SYBR ® green detection, real-time qPCR based on a forensic kit, quantification via fluorescent dyes bonded to DNA, and fragmentary analysis. Differences between groups were tested using a paired t-test. Methods that measure total DNA present in the sample (NanoDrop ™ UV spectrophotometer and Qubit ® fluorometer) showed the highest concentrations. Methods based on real-time qPCR underestimated the quantity of aDNA. The most accurate method of aDNA quantification was fragmentary analysis, which also allows DNA quantification of the desired length and is not affected by PCR inhibitors. Methods based on the quantification of the total amount of DNA in samples are unsuitable for ancient samples as they overestimate the amount of DNA presumably due to the presence of microbial DNA. Real-time qPCR methods give undervalued results due to DNA damage and the presence of PCR inhibitors. DNA quantification methods based on fragment analysis show not only the quantity of DNA but also fragment length.

  14. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  15. Twenty Common Testing Mistakes for EFL Teachers to Avoid

    Science.gov (United States)

    Henning, Grant

    2012-01-01

    To some extent, good testing procedure, like good language use, can be achieved through avoidance of errors. Almost any language-instruction program requires the preparation and administration of tests, and it is only to the extent that certain common testing mistakes have been avoided that such tests can be said to be worthwhile selection,…

  16. Ultrasound versus liver function tests for diagnosis of common bile duct stones.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Giljaca, Vanja; Takwoingi, Yemisi; Higgie, David; Poropat, Goran; Štimac, Davor; Davidson, Brian R

    2015-02-26

    Ultrasound and liver function tests (serum bilirubin and serum alkaline phosphatase) are used as screening tests for the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ultrasound and liver function tests. To determine and compare the accuracy of ultrasound versus liver function tests for the diagnosis of common bile duct stones. We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. We searched the references of included studies to identify further studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects, Health Technology Assessment, Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ultrasound, serum bilirubin, or serum alkaline phosphatase. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test result, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test result as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. Two authors independently collected data from

  17. Improved sensitivity testing of explosives using transformed Up-Down methods

    International Nuclear Information System (INIS)

    Brown, Geoffrey W

    2014-01-01

    Sensitivity tests provide data that help establish guidelines for the safe handling of explosives. Any sensitivity test is based on assumptions to simplify the method or reduce the number of individual sample evaluations. Two common assumptions that are not typically checked after testing are 1) explosive response follows a normal distribution as a function of the applied stimulus levels and 2) the chosen test level spacing is close to the standard deviation of the explosive response function (for Bruceton Up-Down testing for example). These assumptions and other limitations of traditional explosive sensitivity testing can be addressed using Transformed Up-Down (TUD) test methods. TUD methods have been developed extensively for psychometric testing over the past 50 years and generally use multiple tests at a given level to determine how to adjust the applied stimulus. In the context of explosive sensitivity we can use TUD methods that concentrate testing around useful probability levels. Here, these methods are explained and compared to Bruceton Up-Down testing using computer simulation. The results show that the TUD methods are more useful for many cases but that they do require more tests as a consequence. For non-normal distributions, however, the TUD methods may be the only accurate assessment method.

  18. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  19. New Rock Abrasivity Test Method for Tool Life Assessments on Hard Rock Tunnel Boring: The Rolling Indentation Abrasion Test (RIAT)

    Science.gov (United States)

    Macias, F. J.; Dahl, F.; Bruland, A.

    2016-05-01

    The tunnel boring machine (TBM) method has become widely used and is currently an important presence within the tunnelling industry. Large investments and high geological risk are involved using TBMs, and disc cutter consumption has a great influence on performance and cost, especially in hard rock conditions. Furthermore, reliable cutter life assessments facilitate the control of risk as well as avoiding delays and budget overruns. Since abrasive wear is the most common process affecting cutter consumption, good laboratory tests for rock abrasivity assessments are needed. A new abrasivity test method by rolling disc named Rolling Indentation Abrasion Test (RIAT) has been developed. The goal of the new test design and procedure is to reproduce wear behaviour on hard rock tunnel boring in a more realistic way than the traditionally used methods. Wear by rolling contact on intact rock samples is introduced and several rock types, covering a wide rock abrasiveness range, have been tested by RIAT. The RIAT procedure indicates a great ability of the testing method to assess abrasive wear on rolling discs. In addition and to evaluate the newly developed RIAT test method, a comprehensive laboratory testing programme including the most commonly used abrasivity test methods and the mineral composition were carried out. Relationships between the achieved results from conventional testing and RIAT results have been analysed.

  20. Fragmentation of DNA affects the accuracy of the DNA quantitation by the commonly used methods

    Directory of Open Access Journals (Sweden)

    Sedlackova Tatiana

    2013-02-01

    Full Text Available Abstract Background Specific applications and modern technologies, like non-invasive prenatal testing, non-invasive cancer diagnostic and next generation sequencing, are currently in the focus of researchers worldwide. These have common characteristics in use of highly fragmented DNA molecules for analysis. Hence, for the performance of molecular methods, DNA concentration is a crucial parameter; we compared the influence of different levels of DNA fragmentation on the accuracy of DNA concentration measurements. Results In our comparison, the performance of the currently most commonly used methods for DNA concentration measurement (spectrophotometric, fluorometric and qPCR based were tested on artificially fragmented DNA samples. In our comparison, unfragmented and three specifically fragmented DNA samples were used. According to our results, the level of fragmentation did not influence the accuracy of spectrophotometric measurements of DNA concentration, while other methods, fluorometric as well as qPCR-based, were significantly influenced and a decrease in measured concentration was observed with more intensive DNA fragmentation. Conclusions Our study has confirmed that the level of fragmentation of DNA has significant impact on accuracy of DNA concentration measurement with two of three mostly used methods (PicoGreen and qPCR. Only spectrophotometric measurement was not influenced by the level of fragmentation, but sensitivity of this method was lowest among the three tested. Therefore if it is possible the DNA quantification should be performed with use of equally fragmented control DNA.

  1. Common Data Acquisition Systems (DAS) Software Development for Rocket Propulsion Test (RPT) Test Facilities

    Science.gov (United States)

    Hebert, Phillip W., Sr.; Davis, Dawn M.; Turowski, Mark P.; Holladay, Wendy T.; Hughes, Mark S.

    2012-01-01

    The advent of the commercial space launch industry and NASA's more recent resumption of operation of Stennis Space Center's large test facilities after thirty years of contractor control resulted in a need for a non-proprietary data acquisition systems (DAS) software to support government and commercial testing. The software is designed for modularity and adaptability to minimize the software development effort for current and future data systems. An additional benefit of the software's architecture is its ability to easily migrate to other testing facilities thus providing future commonality across Stennis. Adapting the software to other Rocket Propulsion Test (RPT) Centers such as MSFC, White Sands, and Plumbrook Station would provide additional commonality and help reduce testing costs for NASA. Ultimately, the software provides the government with unlimited rights and guarantees privacy of data to commercial entities. The project engaged all RPT Centers and NASA's Independent Verification & Validation facility to enhance product quality. The design consists of a translation layer which provides the transparency of the software application layers to underlying hardware regardless of test facility location and a flexible and easily accessible database. This presentation addresses system technical design, issues encountered, and the status of Stennis development and deployment.

  2. Making Sense of Fear Testing - Validating Common Behavioral Tests used in Swine

    Science.gov (United States)

    Tests to assess fear are commonly used in laboratory animals, such as mice and rats, when researchers wish to understand the implications of specific drugs, such as anxiolytics, or specific environments which may be used to house experimental animals. Researchers who study the welfare of livestock ...

  3. Reliability of fitness tests using methods and time periods common in sport and occupational management.

    Science.gov (United States)

    Burnstein, Bryan D; Steele, Russell J; Shrier, Ian

    2011-01-01

    Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.

  4. The Hull Method for Selecting the Number of Common Factors

    Science.gov (United States)

    Lorenzo-Seva, Urbano; Timmerman, Marieke E.; Kiers, Henk A. L.

    2011-01-01

    A common problem in exploratory factor analysis is how many factors need to be extracted from a particular data set. We propose a new method for selecting the number of major common factors: the Hull method, which aims to find a model with an optimal balance between model fit and number of parameters. We examine the performance of the method in an…

  5. A Simple Method for Assessing Severity of Common Root Rot on Barley

    Directory of Open Access Journals (Sweden)

    Mohammad Imad Eddin Arabi

    2013-12-01

    Full Text Available Common root rot caused by Cochliobolus sativus is a serious disease of barley. A simple and reliable method for assessing this disease would enhance our capacity in identifying resistance sources and developing resistant barley cultivars. In searching for such a method, a conidial suspension of C. sativus was dropped onto sterilized elongated subcrown internodes and incubated in sandwich filter paper using polyethylene transparent envelopes. Initial disease symptoms were easily detected after 48h of inoculation. Highly significant correlation coefficients were found in each experiment (A, B and C between sandwich filter paper and seedling assays, indicating that this testing procedure was reliable. The method presented facilitates a rapid pre-selection under uniform conditions which is of importance from a breeder’s point of view.

  6. Estimation of the common cause failure probabilities of the components under mixed testing schemes

    International Nuclear Information System (INIS)

    Kang, Dae Il; Hwang, Mee Jeong; Han, Sang Hoon

    2009-01-01

    For the case where trains or channels of standby safety systems consisting of more than two redundant components are tested in a staggered manner, the standby safety components within a train can be tested simultaneously or consecutively. In this case, mixed testing schemes, staggered and non-staggered testing schemes, are used for testing the components. Approximate formulas, based on the basic parameter method, were developed for the estimation of the common cause failure (CCF) probabilities of the components under mixed testing schemes. The developed formulas were applied to the four redundant check valves of the auxiliary feed water system as a demonstration study for their appropriateness. For a comparison, we estimated the CCF probabilities of the four redundant check valves for the mixed, staggered, and non-staggered testing schemes. The CCF probabilities of the four redundant check valves for the mixed testing schemes were estimated to be higher than those for the staggered testing scheme, and lower than those for the non-staggered testing scheme.

  7. Chapter 31: Common in vitro tests for allergy and immunology.

    Science.gov (United States)

    Makhija, Melanie; O'Gorman, Maurice R G

    2012-01-01

    Allergen-specific IgE antibody is the most commonly ordered in vitro test in the practice of allergy and is used to diagnose type I hypersensitivity reactions to foods or reactivity to aeroallergens in patients with relative contraindications to skin-prick testing such as dermatographism. The Phadebas radioallergosorbent test (RAST; Pharmacia, Uppsala, Sweden) was the first assay reported for the detection of the allergen-specific IgE antibody. In a RAST, antigen (allergen) is bound to a solid phase, such as a paper disk, and then incubated with human serum. A buffer wash removes unbound serum proteins, and radiolabeled anti-human IgE is added to detect bound IgE, if present. The results are reported in arbitrary units of IgE per milliliter of serum. The term RAST was originally a brand name but it is now often used colloquially (and incorrectly) to describe any in vitro assay for allergen-specific IgE. Total serum IgE can be measured and is helpful in determining atopic presentations such as in allergic bronchopulmonary aspergillosis or in patients with persistent asthma who are candidates for monoclonal anti-IgE antibody therapy with, omalizumab. In patients with recurrent bacterial infections of the sinopulmonary tract, the basic humoral immune system testing includes measuring quantitative immunoglobulins (IgG, IgA, and IgM) and comparing them to age-matched normal ranges. Most clinical laboratories use nephelometry to measure immunoglobulin levels quantitatively. Nephelometry detects either the rate or the end point of soluble immune complex formation (the IgG in sera complexes with an anti-IgG antibody forming a classic immunoprecipitation reaction) by monitoring the scatter of transmitted light. The most common method for the screening of cellular immunodeficiency involved the measurement of the absolute and relative representation of the major lymphocyte subsets, T-cells, T-helper cells, T-cytotoxic cells, B-cells and NK-cells.

  8. Understanding common statistical methods, Part I: descriptive methods, probability, and continuous data.

    Science.gov (United States)

    Skinner, Carl G; Patel, Manish M; Thomas, Jerry D; Miller, Michael A

    2011-01-01

    Statistical methods are pervasive in medical research and general medical literature. Understanding general statistical concepts will enhance our ability to critically appraise the current literature and ultimately improve the delivery of patient care. This article intends to provide an overview of the common statistical methods relevant to medicine.

  9. Drop Test Using Finite Element Method for Transport Package of Radioactive Material

    International Nuclear Information System (INIS)

    Xu Xiaoxiao; Zhao Bing; Zhang Jiangang; Li Gouqiang; Wang Xuexin; Tang Rongyao

    2010-01-01

    Mechanical test for transport package of radioactive material is one of the important tests for demonstrating package structure design. Drop test of package is a kind of destructive test. It is a common method of adopting the pre-analysis to determine drop orientation.Mechanical test of a sealed source package was calculated with finite element method (FEM) software. Based on the analysis of the calculation results, some values were obtained such as the stress, strain, acceleration and the drop orientation which causes the most severe damage, and the calculation results were compared with the results of test. (authors)

  10. Standard test method for distribution coefficients of inorganic species by the batch method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of distribution coefficients of chemical species to quantify uptake onto solid materials by a batch sorption technique. It is a laboratory method primarily intended to assess sorption of dissolved ionic species subject to migration through pores and interstices of site specific geomedia. It may also be applied to other materials such as manufactured adsorption media and construction materials. Application of the results to long-term field behavior is not addressed in this method. Distribution coefficients for radionuclides in selected geomedia are commonly determined for the purpose of assessing potential migratory behavior of contaminants in the subsurface of contaminated sites and waste disposal facilities. This test method is also applicable to studies for parametric studies of the variables and mechanisms which contribute to the measured distribution coefficient. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement a...

  11. Comparison of eight methods for the extraction of Bacillus atrophaeus spore DNA from eleven common interferents and a common swab.

    Directory of Open Access Journals (Sweden)

    Helen L Rose

    Full Text Available Eight DNA extraction products or methods (Applied Biosystems PrepFiler Forensic DNA Extraction Kit; Bio-Rad Instagene Only, Bio-Rad Instagene & Spin Column Purification; EpiCentre MasterPure DNA & RNA Kit; FujiFilm QuickGene Mini80; Idaho Technologies 1-2-3 Q-Flow Kit; MoBio UltraClean Microbial DNA Isolation Kit; Sigma Extract-N-Amp Plant and Seed Kit were adapted to facilitate extraction of DNA under BSL3 containment conditions. DNA was extracted from 12 common interferents or sample types, spiked with spores of Bacillus atropheaus. Resulting extracts were tested by real-time PCR. No one method was the best, in terms of DNA extraction, across all sample types. Statistical analysis indicated that the PrepFiler method was the best method from six dry powders (baking, biological washing, milk, plain flour, filler and talcum and one solid (Underarm deodorant, the UltraClean method was the best from four liquids (aftershave, cola, nutrient broth, vinegar, and the MasterPure method was the best from the swab sample type. The best overall method, in terms of DNA extraction, across all sample types evaluated was the UltraClean method.

  12. Common Risk Criteria Standards for National Test Ranges

    Science.gov (United States)

    2016-08-01

    supplemental) document to RCC Document 321. a. Modified aircraft vulnerability criteria for business class jets. b. Modified the aircraft vulnerability... successful , the logical relationships among criteria used at the test ranges and across different hazards are often difficult to comprehend. The...provides a common set of range safety policies, risk criteria, and guidelines for managing risk to people and assets during manned and unmanned

  13. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  14. An assessment of existing common traditional methods of water ...

    African Journals Online (AJOL)

    Classical water purification methods include boiling, filtration, irradiation and the use of chemicals while traditional water purification methods in use are boiling, filtration, sedimentation, long storage and solar radiation. Waterborne diseases are m ore common in the rural communities where potable water supply coverage ...

  15. Systematic evaluation of non-animal test methods for skin sensitisation safety assessment.

    Science.gov (United States)

    Reisinger, Kerstin; Hoffmann, Sebastian; Alépée, Nathalie; Ashikaga, Takao; Barroso, Joao; Elcombe, Cliff; Gellatly, Nicola; Galbiati, Valentina; Gibbs, Susan; Groux, Hervé; Hibatallah, Jalila; Keller, Donald; Kern, Petra; Klaric, Martina; Kolle, Susanne; Kuehnl, Jochen; Lambrechts, Nathalie; Lindstedt, Malin; Millet, Marion; Martinozzi-Teissier, Silvia; Natsch, Andreas; Petersohn, Dirk; Pike, Ian; Sakaguchi, Hitoshi; Schepky, Andreas; Tailhardat, Magalie; Templier, Marie; van Vliet, Erwin; Maxwell, Gavin

    2015-02-01

    The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has defined a three-phase framework for the development of a non-animal testing strategy for skin sensitization potency prediction. The results of the first phase – systematic evaluation of 16 test methods – are presented here. This evaluation involved generation of data on a common set of ten substances in all methods and systematic collation of information including the level of standardisation, existing test data,potential for throughput, transferability and accessibility in cooperation with the test method developers.A workshop was held with the test method developers to review the outcome of this evaluation and to discuss the results. The evaluation informed the prioritisation of test methods for the next phase of the non-animal testing strategy development framework. Ultimately, the testing strategy – combined with bioavailability and skin metabolism data and exposure consideration – is envisaged to allow establishment of a data integration approach for skin sensitisation safety assessment of cosmetic ingredients.

  16. Common Allergens Identified Based on Patch Test Results in Patients with Suspected Contact Dermatitis of the Scalp

    Science.gov (United States)

    Aleid, Nouf M.; Fertig, Raymond; Maddy, Austin; Tosti, Antonella

    2017-01-01

    Background Contact dermatitis of the scalp is common and might be caused by many chemicals including metals, ingredients of shampoos and conditioners, dyes, or other hair treatments. Eliciting a careful history and patch tests are necessary to identify the responsible allergen and prevent relapses. Objectives To identify allergens that may cause contact dermatitis of the scalp by reviewing patch test results. Methods We reviewed the records of 1,015 patients referred for patch testing at the Dermatology Department of the University of Miami. A total of 226 patients (205 females and 21 males) with suspected scalp contact dermatitis were identified, and the patch test results and clinical data for those patients were analyzed. Most patients were referred for patch testing from a specialized hair clinic at our institution. Results The most common allergens in our study population were nickel (23.8%), cobalt (21.0%), balsam of Peru (18.2%), fragrance mix (14.4%), carba mix (11.6%), and propylene glycol (PG) (8.8%). The majority of patients were females aged 40–59 years, and scalp itching or burning were reported as the most common symptom. Conclusion Frequent sources of allergens for metals include hair clasps, pins, and brushes, while frequent sources of allergens for preservatives, fragrance mix, and balsam of Peru include shampoos, conditioners, and hair gels. Frequent sources of allergens for PG include topical medications. PMID:28611994

  17. Multiple linear combination (MLC) regression tests for common variants adapted to linkage disequilibrium structure.

    Science.gov (United States)

    Yoo, Yun Joo; Sun, Lei; Poirier, Julia G; Paterson, Andrew D; Bull, Shelley B

    2017-02-01

    By jointly analyzing multiple variants within a gene, instead of one at a time, gene-based multiple regression can improve power, robustness, and interpretation in genetic association analysis. We investigate multiple linear combination (MLC) test statistics for analysis of common variants under realistic trait models with linkage disequilibrium (LD) based on HapMap Asian haplotypes. MLC is a directional test that exploits LD structure in a gene to construct clusters of closely correlated variants recoded such that the majority of pairwise correlations are positive. It combines variant effects within the same cluster linearly, and aggregates cluster-specific effects in a quadratic sum of squares and cross-products, producing a test statistic with reduced degrees of freedom (df) equal to the number of clusters. By simulation studies of 1000 genes from across the genome, we demonstrate that MLC is a well-powered and robust choice among existing methods across a broad range of gene structures. Compared to minimum P-value, variance-component, and principal-component methods, the mean power of MLC is never much lower than that of other methods, and can be higher, particularly with multiple causal variants. Moreover, the variation in gene-specific MLC test size and power across 1000 genes is less than that of other methods, suggesting it is a complementary approach for discovery in genome-wide analysis. The cluster construction of the MLC test statistics helps reveal within-gene LD structure, allowing interpretation of clustered variants as haplotypic effects, while multiple regression helps to distinguish direct and indirect associations. © 2016 The Authors Genetic Epidemiology Published by Wiley Periodicals, Inc.

  18. Note: An online testing method for lifetime projection of high power light-emitting diode under accelerated reliability test.

    Science.gov (United States)

    Chen, Qi; Chen, Quan; Luo, Xiaobing

    2014-09-01

    In recent years, due to the fast development of high power light-emitting diode (LED), its lifetime prediction and assessment have become a crucial issue. Although the in situ measurement has been widely used for reliability testing in laser diode community, it has not been applied commonly in LED community. In this paper, an online testing method for LED life projection under accelerated reliability test was proposed and the prototype was built. The optical parametric data were collected. The systematic error and the measuring uncertainty were calculated to be within 0.2% and within 2%, respectively. With this online testing method, experimental data can be acquired continuously and sufficient amount of data can be gathered. Thus, the projection fitting accuracy can be improved (r(2) = 0.954) and testing duration can be shortened.

  19. Common Core Standards and their Impact on Standardized Test Design

    NARCIS (Netherlands)

    Polleck, J.N.; Jeffery, J.V.

    2017-01-01

    With adoption of the Common Core (CCSS) in a majority of U.S. states came developmentof new high-stakes exams. Though researchers have investigated CCSS andrelated policies, less attention has been directed toward understanding how standardsare translated into testing. Due to the influence that

  20. Common Data Acquisition Systems (DAS) Software Development for Rocket Propulsion Test (RPT) Test Facilities - A General Overview

    Science.gov (United States)

    Hebert, Phillip W., Sr.; Hughes, Mark S.; Davis, Dawn M.; Turowski, Mark P.; Holladay, Wendy T.; Marshall, PeggL.; Duncan, Michael E.; Morris, Jon A.; Franzl, Richard W.

    2012-01-01

    The advent of the commercial space launch industry and NASA's more recent resumption of operation of Stennis Space Center's large test facilities after thirty years of contractor control resulted in a need for a non-proprietary data acquisition system (DAS) software to support government and commercial testing. The software is designed for modularity and adaptability to minimize the software development effort for current and future data systems. An additional benefit of the software's architecture is its ability to easily migrate to other testing facilities thus providing future commonality across Stennis. Adapting the software to other Rocket Propulsion Test (RPT) Centers such as MSFC, White Sands, and Plumbrook Station would provide additional commonality and help reduce testing costs for NASA. Ultimately, the software provides the government with unlimited rights and guarantees privacy of data to commercial entities. The project engaged all RPT Centers and NASA's Independent Verification & Validation facility to enhance product quality. The design consists of a translation layer which provides the transparency of the software application layers to underlying hardware regardless of test facility location and a flexible and easily accessible database. This presentation addresses system technical design, issues encountered, and the status of Stennis' development and deployment.

  1. Global/local methods research using a common structural analysis framework

    Science.gov (United States)

    Knight, Norman F., Jr.; Ransom, Jonathan B.; Griffin, O. H., Jr.; Thompson, Danniella M.

    1991-01-01

    Methodologies for global/local stress analysis are described including both two- and three-dimensional analysis methods. These methods are being developed within a common structural analysis framework. Representative structural analysis problems are presented to demonstrate the global/local methodologies being developed.

  2. A novel test tube method of screening for hemoglobin E.

    Science.gov (United States)

    Tatu, T; Kasinrerk, W

    2012-02-01

    Hemoglobin (Hb) E is a β-structural variant common worldwide. This Hb disorder can form a compound heterozygous state with the β-thalassemia gene, leading to life-threatening hereditary hemolytic anemia, HbE/β-thalassemia. Screening of HbE has proven to be a challenging practice in prevention and control of the HbE/β-thalassemia. A novel test tube method for HbE screening using diethyl aminoethyl (DEAE)-cellulose resin was described. With the developed system, HbE/A(2) did not bind to the resin and remained dissolved in the supernatant, whereas other Hbs completely bound to the resin. The red color of the supernatant observed in the test tube indicated the presence of HbE. Colorless or markedly pale color of the supernatant indicates the absence of HbE. Accuracy and efficiency of the established method in detecting HbE was comparable with the standard cellulose acetate electrophoresis method. The developed method is cheap and simple with no requirement of sophisticated equipment. The reagent could be stored at 4 °C for up to 5 months. Hemolysate samples aged up to 5 months were still suitable for this test. The described novel test tube method could be an alternative method of mass population screening for HbE, particularly in small health care facilities. © 2011 Blackwell Publishing Ltd.

  3. Exploring two methods of usability testing: concurrent versus retrospective think-aloud protocols

    NARCIS (Netherlands)

    van den Haak, M.J.; de Jong, Menno D.T.

    2003-01-01

    Think-aloud protocols are commonly used for the usability testing of instructional documents, Web sites and interfaces. This paper addresses the benefits and drawbacks of two think-aloud variations: the traditional concurrent think-aloud method and the less familiar retrospective think-aloud

  4. Exploring Two Methods of Usability Testing : Concurrent versus Retrospective Think-Aloud Protocols

    NARCIS (Netherlands)

    Van den Haak, Maaike J.; De Jong, Menno D. T.

    2003-01-01

    Think-aloud protocols are commonly used for the usability testing of instructional documents, web sites and interfaces. This paper addresses the benefits and drawbacks of two think-aloud variations: the traditional concurrent think-aloud method and the less familiar retrospective think-aloud

  5. Studies on Hepa filter test methods

    International Nuclear Information System (INIS)

    Lee, S.H.; Jon, K.S.; Park, W.J.; Ryoo, R.

    1981-01-01

    The purpose of this study is to compare testing methods of the HEPA filter adopted in other countries with each other, and to design and construct a test duct system to establish testing methods. The American D.O.P. test method, the British NaCl test method and several other independently developed methods are compared. It is considered that the D.O.P. method is most suitable for in-plant and leak tests

  6. HER2 testing in the UK: recommendations for breast and gastric in-situ hybridisation methods

    LENUS (Irish Health Repository)

    Bartlett, J. M. S.

    2011-01-01

    These guidelines supplement existing guidelines on HER2 testing by immunohistochemistry and in-situ hybridisation(ISH) methods in the UK. They provide a specific focus on aspects of guidance relevant to HER2 ISH testing methods, both fluorescent and chromogenic. They are formulated to give advice on methodology, interpretation and quality control for ISH-based testing of HER2 status in common tumour types, including both breast and gastric tumours. The aim is to ensure that all ISH-based testing is accurate, reliable and timely.

  7. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-01-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results are presented: the radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach test methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transporation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance

  8. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-11-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results is presented: The radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach tests methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transportation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance. 2 references, 2 figures

  9. Analysis Method of Common Cause Failure on Non-safety Digital Control System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Goo; Oh, Eun Gse [KHNP, Daejeon (Korea, Republic of)

    2014-08-15

    The effects of common cause failure on safety digital instrumentation and control system had been considered in defense in depth analysis with safety analysis method. However, the effects of common cause failure on non-safety digital instrumentation and control system also should be evaluated. The common cause failure can be included in credible failure on the non-safety system. In the I and C architecture of nuclear power plant, many design feature has been applied for the functional integrity of control system. One of that is segmentation. Segmentation defenses the propagation of faults in the I and C architecture. Some of effects from common cause failure also can be limited by segmentation. Therefore, in this paper there are two type of failure mode, one is failures in one control group which is segmented, and the other is failures in multiple control group because that the segmentation cannot defense all effects from common cause failure. For each type, the worst failure scenario is needed to be determined, so the analysis method has been proposed in this paper. The evaluation can be qualitative when there is sufficient justification that the effects are bounded in previous safety analysis. When it is not bounded in previous safety analysis, additional analysis should be done with conservative assumptions method of previous safety analysis or best estimation method with realistic assumptions.

  10. Comparison of PCR and common clinical tests for the diagnosis of H. pylori in dyspeptic patients.

    Science.gov (United States)

    Pacheco, N; Mago, V; Gómez, I; Gueneau, P; Guelrud, M; Reyes, N; Pericchi, L R; Domínguez-Bello, M G

    2001-04-01

    Helicobacter pylori has been recognized as a major gastric pathogen. The objective of this study was to assess the diagnostic value of common clinical tests to detect H. pylori infection, by comparison with PCR. Serum and gastric biopsy specimens from 106 dyspeptic patients were examined. Serology was performed with Pyloriset Dry test, and biopsies were examined histologically, for rapid urease activity and PCR amplification of an ureA gene segment of H. pylori. PCR primers were specific for H. pylori and required at least 1.47 pg of H. pylori DNA, corresponding to about 800 bacterial cells. According to serology, histology, rapid urease, and PCR, positive results were respectively found in 56%, 86%, 64%, and 85% of dyspeptic patients, primarily with gastritis. Relative to PCR, the sensitivity (and specificity) was 55% (38%) for serology, 86% (13%) for histology, 70% (69%) for urease. When combining histology and urease, Bayesian analysis of data indicated no advantage of using combined methods over rapid urease test alone. Histology should not any longer be considered a gold standard test for Helicobacter pylori. Urea breath test still seems the first option for non invasive diagnostic. If an invasive diagnostic is justified, highly specific and sensitive molecular methods should be used to examine specimens.

  11. Semiconductor testing method

    International Nuclear Information System (INIS)

    Brown, Stephen.

    1992-01-01

    In a method of avoiding use of nuclear radiation, eg gamma rays, X-rays, electron beams, for testing semiconductor components for resistance to hard radiation, which hard radiation causes data corruption in some memory devices and 'latch-up' in others, similar fault effects can be achieved using a xenon or other 'light' flash gun even though the penetration of light is significantly less than that of gamma rays. The method involves treating a device with gamma radiation, measuring a particular fault current at the onset of a fault event, repeating the test with light to confirm the occurrence of the fault event at the same measured fault current, and using the fault current value as a reference for future tests using light on similar devices. (author)

  12. The Threat of Common Method Variance Bias to Theory Building

    Science.gov (United States)

    Reio, Thomas G., Jr.

    2010-01-01

    The need for more theory building scholarship remains one of the pressing issues in the field of HRD. Researchers can employ quantitative, qualitative, and/or mixed methods to support vital theory-building efforts, understanding however that each approach has its limitations. The purpose of this article is to explore common method variance bias as…

  13. Phototoxicity: Its Mechanism and Animal Alternative Test Methods

    Science.gov (United States)

    Park, Hyeonji; Lim, Kyung-Min

    2015-01-01

    The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential. PMID:26191378

  14. Common pitfalls in statistical analysis: Understanding the properties of diagnostic tests - Part 1.

    Science.gov (United States)

    Ranganathan, Priya; Aggarwal, Rakesh

    2018-01-01

    In this article in our series on common pitfalls in statistical analysis, we look at some of the attributes of diagnostic tests (i.e., tests which are used to determine whether an individual does or does not have disease). The next article in this series will focus on further issues related to diagnostic tests.

  15. Modern methods of high-pressure fuel pump common rail power system diagnostics

    Directory of Open Access Journals (Sweden)

    Kyshchun В.

    2016-08-01

    Full Text Available We've considered high pressure fuel pumps design features and equipment for their diagnosis. It was noted that the reliability of the fuel elements Common Rail system primarily provide precision parts of the fuel equipment. As a consequence, the aim of study was comparative analysis and laborious of modern methods of the high pressure fuel pump diagnosing. In particular, the definition of a technical condition of the fuel pump was carried out using a special stand and by measuring the fuel pressure and duty cycle of the pressure regulator signal. As an object of our research we've chosen Bosch № 0445010008 fuel pump (from Mercedes Benz E320cdi in which the plunger pairs were changed alternately with different technical conditions. Preliminary fuel pump parameters were determined by hydraulic testing. Based on conducted experiments we've found out that fuel pressure measurement change method and the duty cycle of the pressure regulator signal at the starting and full load modes less laborious compared to the definition of a technical condition of the pump on the stand. The results of both methods of diagnosing confirmed identity of the fuel pumps.

  16. A method of directly extracting multiwave angle-domain common-image gathers

    Science.gov (United States)

    Han, Jianguang; Wang, Yun

    2017-10-01

    Angle-domain common-image gathers (ADCIGs) can provide an effective way for migration velocity analysis and amplitude versus angle analysis in oil-gas seismic exploration. On the basis of multi-component Gaussian beam prestack depth migration (GB-PSDM), an alternative method of directly extracting multiwave ADCIGs is presented in this paper. We first introduce multi-component GB-PSDM, where a wavefield separation is proceeded to obtain the separated PP- and PS-wave seismic records before migration imaging for multiwave seismic data. Then, the principle of extracting PP- and PS-ADCIGs using GB-PSDM is presented. The propagation angle can be obtained using the real-value travel time of Gaussian beam in the course of GB-PSDM, which can be used to calculate the incidence and reflection angles. Two kinds of ADCIGs can be extracted for the PS-wave, one of which is P-wave incidence ADCIGs and the other one is S-wave reflection ADCIGs. In this paper, we use the incident angle to plot the ADCIGs for both PP- and PS-waves. Finally, tests of synthetic examples show that the method introduced here is accurate and effective.

  17. A Comparison of Methods to Test Mediation and Other Intervening Variable Effects

    Science.gov (United States)

    MacKinnon, David P.; Lockwood, Chondra M.; Hoffman, Jeanne M.; West, Stephen G.; Sheets, Virgil

    2010-01-01

    A Monte Carlo study compared 14 methods to test the statistical significance of the intervening variable effect. An intervening variable (mediator) transmits the effect of an independent variable to a dependent variable. The commonly used R. M. Baron and D. A. Kenny (1986) approach has low statistical power. Two methods based on the distribution of the product and 2 difference-in-coefficients methods have the most accurate Type I error rates and greatest statistical power except in 1 important case in which Type I error rates are too high. The best balance of Type I error and statistical power across all cases is the test of the joint significance of the two effects comprising the intervening variable effect. PMID:11928892

  18. Methodology for developing new test methods

    Directory of Open Access Journals (Sweden)

    A. I. Korobko

    2017-06-01

    Full Text Available The paper describes the methodology for developing new test methods and forming solutions for the development of new test methods. The basis of the methodology for developing new test methods is the individual elements of the system and process approaches. They contribute to the development of an effective research strategy for the object, the study of interrelations, the synthesis of an adequate model of the test method. The effectiveness of the developed test method is determined by the correct choice of the set of concepts, their interrelations and mutual influence. This allows you to solve the tasks assigned to achieve the goal. The methodology is based on the use of fuzzy cognitive maps. The question of the choice of the method on the basis of which the model for the formation of solutions is based is considered. The methodology provides for recording a model for a new test method in the form of a finite set of objects. These objects are significant for the test method characteristics. Then a causal relationship is established between the objects. Further, the values of fitness indicators and the observability of the method and metrological tolerance for the indicator are established. The work is aimed at the overall goal of ensuring the quality of tests by improving the methodology for developing the test method.

  19. WEATHER DERIVATIVES: THE MOST COMMON PRICING AND VALUATION METHODS

    Directory of Open Access Journals (Sweden)

    Botos Horia Mircea

    2013-07-01

    Full Text Available In recent years , weather derivatives have become a common tool in risk management for many sectors. This has its roots in that there is no unique way to determine de value and price solutions that would be generally approved by market-participants, like in the case of the Black-Scholes formula for options on non-dividend-paying stocks is the source for a constant debate between academics and practitioners. One look for fair and truly correct prices, while the others search every-day applicable solutions. To be honest... this is somehow like alchemy. This paper has as purpose the examination of statistical characteristics of weather data, data clearing and filling techniques. The study will be referring to temperatures because that is the best analyzed phenomenon, being the most common. This was also heavily influenced by energy companies and energetic interests, because the degree days were of interest ever before weather derivatives were put for sale. Main ideas are explaining what ways of pricing and valuation are, put into perspective for this financial instrument, taking into consideration that the Black-Scholes Model is not suitable. Also here, we will present the pros and cons that we found for each method. The methods are: the Burn analysis, the index value simulation method (IVSM, the daily simulation method (DSM.On the hole, this paper wants to shed light the weather derivatives pricing methods a mix of insurance pricing and standard financial models. At the end we will prospect the discounting problem, by means of the Consumption based Capital Asset Pricing Model (CCAPM.

  20. Are effects of common ragwort in the Ames test caused by pyrrolizidine alkaloids?

    Science.gov (United States)

    Bovee, Toine F H; Helsdingen, Richard J R; Hoogenboom, Ron L A P; de Nijs, Monique W C M; Liu, Xiaojie; Vrieling, Klaas; Klinkhamer, Peter G L; Peijnenburg, Ad A C M; Mulder, Patrick P J

    2015-08-01

    It has previously been demonstrated by others that acetone extracts of Senecio jacobaea (syn. Jacobaea vulgaris, common or tansy ragwort) test positive in the Salmonella/microsome mutagenicity test (Ames test). Pyrrolizidine alkaloids (PAs) are thought to be responsible for these mutagenic effects. However, it was also observed that the major PA present in common ragwort, jacobine, produced a negative response (with and without the addition of rat liver S9) in Salmonella test strains TA98, TA100, TA1535 and TA1537. To investigate which compounds in the plant extracts were responsible for the positive outcome, the present study investigated the contents and mutagenic effects of methanol and acetone extracts prepared from dried ground S. jacobaea and Senecio inaequidens (narrow-leafed ragwort). Subsequently, a fractionation approach was set up in combination with LC-MS/MS analysis of the fractions. It was shown that the positive Ames test outcomes of S. jacobaea extracts are unlikely to be caused by PAs, but rather by the flavonoid quercetin. This study also demonstrates the importance of identifying compounds responsible for positive test results in bioassays. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. 49 CFR 383.133 - Testing methods.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Testing methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Testing methods. (a) All tests shall be constructed in... must be at least as stringent as the Federal standards. (c) States shall determine specific methods for...

  2. Testing common stream sampling methods for broad-scale, long-term monitoring

    Science.gov (United States)

    Eric K. Archer; Brett B. Roper; Richard C. Henderson; Nick Bouwes; S. Chad Mellison; Jeffrey L. Kershner

    2004-01-01

    We evaluated sampling variability of stream habitat sampling methods used by the USDA Forest Service and the USDI Bureau of Land Management monitoring program for the upper Columbia River Basin. Three separate studies were conducted to describe the variability of individual measurement techniques, variability between crews, and temporal variation throughout the summer...

  3. Coordinate alignment of combined measurement systems using a modified common points method

    Science.gov (United States)

    Zhao, G.; Zhang, P.; Xiao, W.

    2018-03-01

    The co-ordinate metrology has been extensively researched for its outstanding advantages in measurement range and accuracy. The alignment of different measurement systems is usually achieved by integrating local coordinates via common points before measurement. The alignment errors would accumulate and significantly reduce the global accuracy, thus need to be minimized. In this thesis, a modified common points method (MCPM) is proposed to combine different traceable system errors of the cooperating machines, and optimize the global accuracy by introducing mutual geometric constraints. The geometric constraints, obtained by measuring the common points in individual local coordinate systems, provide the possibility to reduce the local measuring uncertainty whereby enhance the global measuring certainty. A simulation system is developed in Matlab to analyze the feature of MCPM using the Monto-Carlo method. An exemplary setup is constructed to verify the feasibility and efficiency of the proposed method associated with laser tracker and indoor iGPS systems. Experimental results show that MCPM could significantly improve the alignment accuracy.

  4. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    El-Bordany Ayman; Yun, Won Young

    2014-01-01

    It reads inputs, computes new states, and updates output for each scan cycle. Korea Nuclear Instrumentation and Control System (KNICS) has recently developed a fully digitalized Reactor Protection System (RPS) based on PLD. As a digital system, this RPS is equipped with a dedicated software. The Reliability of this software is crucial to NPPs safety where its malfunction may cause irreversible consequences and affect the whole system as a Common Cause Failure (CCF). To guarantee the reliability of the whole system, the reliability of this software needs to be quantified. There are three representative methods for software reliability quantification, namely the Verification and Validation (V and V) quality-based method, the Software Reliability Growth Model (SRGM), and the test-based method. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values

  5. 40 CFR 63.547 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  6. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  7. The Effect of Error in Item Parameter Estimates on the Test Response Function Method of Linking.

    Science.gov (United States)

    Kaskowitz, Gary S.; De Ayala, R. J.

    2001-01-01

    Studied the effect of item parameter estimation for computation of linking coefficients for the test response function (TRF) linking/equating method. Simulation results showed that linking was more accurate when there was less error in the parameter estimates, and that 15 or 25 common items provided better results than 5 common items under both…

  8. Materials and test methods

    International Nuclear Information System (INIS)

    Kase, M.B.

    1985-01-01

    The objective of this study was to provide, in cooperation with ORNL and LANL, specimens required for studies to develop organic insulators having the cryogenic neutron irradiation resistance required for MFE systems utilizing superconducting magnetic confinement. To develop test methods and analytical procedures for assessing radiation damage. To stimulate and participate in international cooperation directed toward accomplishing these objectives. The system for producing uniaxially reinforced, 3-4 mm (0.125 in) diameter rod specimens has been refined and validated by production of excellent quality specimens using liquid-mix epoxy resin systems. The methodology is undergoing further modification to permit use of hot-melt epoxy and polyimide resin systems as will be required for the experimental program to be conducted in the NLTNIF reactor at ORNL. Preliminary studies indicate that short beam and torsional shear test methods will be useful in evaluating radiation degradation. Development of these and other applicable test methods are continuing. A cooperative program established with laboratories in Japan and in England has resulted in the production and testing of specimens having an identical configuration

  9. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  10. Evaluation of semisolid agar method for antifungal susceptibility test of T. rubrum

    Directory of Open Access Journals (Sweden)

    Sultana Razia

    2016-08-01

    Full Text Available Background: With increasing fungal disease many newer antifungal drugs are available with different spectrum of activ­ity. Antifungal susceptibility test will help clinicians for selection of effective drug and thereby treatment of patient. Objective: The study was undertaken to perform a simple screening drug susceptibility test of T. rnbrum by Semi Solid Agar Antifungal Susceptibility (SAAS Method: Perfonnance of susceptibility method was assessed by comparing the MICs of three commonly prescribed antifungal agents namely- tluconazole (FCZ, itraconazole (ITZ and terbinafine (TER to the CLSI (Clinical and Laboratory Standard Institute recommended M-38, a broth microdilution method. Results: In SAAS method, among twenty nine T. rubrum, twenty five (86.2% were susceptible (MIC range 0.5-64 µg/ml to Fluconazole (FCZ and four (13.7% were resistant (MIC value >64 µg/ml. In broth microdilution method, among twenty nine T. rubrum, twenty six (89.6% were susceptible (MIC range 0.3-64 µg/ml to FCZ and three (10.3% were resistant (MIC value >64 µg/ml. In case of both ITZ and TER, all were susceptible (MIC range 0.3-64 µg/ml to both methods. The SAAS method demonstrated the susceptibility pattern of T. rubrum against FCZ, ITZ and TER usually within 72 to 96 hours after organism isolation and results were concordance with the results of CLSI broth microdilution method. Conclusion: Though it is a newer method with proper standardization of the test method, SAAS method is simple and easily applicable screening method for susceptibility testing of antifungal agents against dermatophytes in any microbiology laboratories.

  11. A Method to Select Test Input Cases for Safety-critical Software

    International Nuclear Information System (INIS)

    Kim, Heeeun; Kang, Hyungook; Son, Hanseong

    2013-01-01

    This paper proposes a new testing methodology for effective and realistic quantification of RPS software failure probability. Software failure probability quantification is important factor in digital system safety assessment. In this study, the method for software test case generation is briefly described. The test cases generated by this method reflect the characteristics of safety-critical software and past inputs. Furthermore, the number of test cases can be reduced, but it is possible to perform exhaustive test. Aspect of software also can be reflected as failure data, so the final failure data can include the failure of software itself and external influences. Software reliability is generally accepted as the key factor in software quality since it quantifies software failures which can make a powerful system inoperative. In the KNITS (Korea Nuclear Instrumentation and Control Systems) project, the software for the fully digitalized reactor protection system (RPS) was developed under a strict procedure including unit testing and coverage measurement. Black box testing is one type of Verification and validation (V and V), in which given input values are entered and the resulting output values are compared against the expected output values. Programmable logic controllers (PLCs) were used in implementing critical systems and function block diagram (FBD) is a commonly used implementation language for PLC

  12. A comparative study of three cytotoxicity test methods for nanomaterials using sodium lauryl sulfate.

    Science.gov (United States)

    Kwon, Jae-Sung; Kim, Kwang-Mahn; Kim, Kyoung-Nam

    2014-10-01

    The biocompatibility evaluation of nanomaterials is essential for their medical diagnostic and therapeutic usage, where a cytotoxicity test is the simplest form of biocompatibility evaluation. Three methods have been commonly used in previous studies for the cytotoxicity testing of nanomaterials: trypan blue exclusion, colorimetric assay using water soluble tetrazolium (WST), and imaging under a microscope following calcein AM/ethidium homodimer-1 staining. However, there has yet to be a study to compare each method. Therefore, in this study three methods were compared using the standard reference material of sodium lauryl sulfate (SLS). Each method of the cytotoxicity test was carried out using mouse fibroblasts of L-929 exposed to different concentrations of SLS. Compared to the gold standard trypan blue exclusion test, both colorimetric assay using water soluble tetrazolium (WST) and imaging under microscope with calcein AM/ethidium homodimer-1 staining showed results that were not statistically different. Also, each method exhibited various advantages and disadvantages, which included the need of equipment, time taken for the experiment, and provision of additional information such as cell morphology. Therefore, this study concludes that all three methods of cytotoxicity testing may be valid, though careful consideration will be needed when selecting tests with regard to time, finances, and the amount of information required by the researcher(s).

  13. 40 CFR 80.3 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods. 80.3 Section 80.3... FUELS AND FUEL ADDITIVES General Provisions § 80.3 Test methods. The lead and phosphorus content of gasoline shall be determined in accordance with test methods set forth in the appendices to this part. [47...

  14. 40 CFR 63.1546 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Test methods. 63.1546 Section 63.1546... Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Test methods. (a) The following procedure shall....1543(a)(1) through § 63.1543(a)(9) shall be determined according to the following test methods in...

  15. 30 CFR 27.31 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 27.31 Section 27.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.31 Testing methods. A methane...

  16. Could Daylight Glare Be Defined Mathematically?Results of Testing the DGIN Method in Japan

    Science.gov (United States)

    Nazzal, Ali; Oki, Masato

    Discomfort glare from daylight is a common problem without valid prediction methods so far. A new mathematical DGIN (New Daylight Glare Index) method tries to respond the challenge. This paper reports on experiments carried out in daylit office environment in Japan to test applicability of the method. Slight positive correlation was found between the DGIN and the subjective evaluation. Additionally, a high Ladaptation value together with the small ratio of Lwindow to Ladaptation was obviously experienced sufficient to neutralize the effect of glare discomfort. However, subjective assessments are poor glare indicators and not reliable in testing glare prediction methods. DGIN is a good indicator of daylight glare, and when the DGIN value is analyzed together with the measured illuminance ratios, discomfort glare from daylight can be analyzed in a quantitative manner. The DGIN method could serve architects and lighting designers in testing daylighting systems, and also guide the action of daylight responsive lighting controls.

  17. A Teaching Method on Basic Chemistry for Freshman : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2003-01-01

    This report deals with a teaching method on basic chemistry for freshman. This teaching method contains guidance and instruction to how to understand basic chemistry. Pre-test and post-test have been put into practice each time. Each test was returned to students at class in the following weeks.

  18. Developing Common Set of Weights with Considering Nondiscretionary Inputs and Using Ideal Point Method

    Directory of Open Access Journals (Sweden)

    Reza Kiani Mavi

    2013-01-01

    Full Text Available Data envelopment analysis (DEA is used to evaluate the performance of decision making units (DMUs with multiple inputs and outputs in a homogeneous group. In this way, the acquired relative efficiency score for each decision making unit lies between zero and one where a number of them may have an equal efficiency score of one. DEA successfully divides them into two categories of efficient DMUs and inefficient DMUs. A ranking for inefficient DMUs is given but DEA does not provide further information about the efficient DMUs. One of the popular methods for evaluating and ranking DMUs is the common set of weights (CSW method. We generate a CSW model with considering nondiscretionary inputs that are beyond the control of DMUs and using ideal point method. The main idea of this approach is to minimize the distance between the evaluated decision making unit and the ideal decision making unit (ideal point. Using an empirical example we put our proposed model to test by applying it to the data of some 20 bank branches and rank their efficient units.

  19. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  20. Common pitfalls in statistical analysis: The perils of multiple testing

    Science.gov (United States)

    Ranganathan, Priya; Pramesh, C. S.; Buyse, Marc

    2016-01-01

    Multiple testing refers to situations where a dataset is subjected to statistical testing multiple times - either at multiple time-points or through multiple subgroups or for multiple end-points. This amplifies the probability of a false-positive finding. In this article, we look at the consequences of multiple testing and explore various methods to deal with this issue. PMID:27141478

  1. Dynamical response of the Galileo Galilei on the ground rotor to test the equivalence principle: Theory, simulation, and experiment. II. The rejection of common mode forces

    International Nuclear Information System (INIS)

    Comandi, G.L.; Toncelli, R.; Chiofalo, M.L.; Bramanti, D.; Nobili, A.M.

    2006-01-01

    'Galileo Galilei on the ground' (GGG) is a fast rotating differential accelerometer designed to test the equivalence principle (EP). Its sensitivity to differential effects, such as the effect of an EP violation, depends crucially on the capability of the accelerometer to reject all effects acting in common mode. By applying the theoretical and simulation methods reported in Part I of this work, and tested therein against experimental data, we predict the occurrence of an enhanced common mode rejection of the GGG accelerometer. We demonstrate that the best rejection of common mode disturbances can be tuned in a controlled way by varying the spin frequency of the GGG rotor

  2. 7 CFR 58.644 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...

  3. Comparison of shear-wave velocity measurements by crosshole, downhole and seismic cone penetration test methods

    Energy Technology Data Exchange (ETDEWEB)

    Suthaker, N.; Tweedie, R. [Thurber Engineering Ltd., Edmonton, AB (Canada)

    2009-07-01

    Shear wave velocity measurements are an integral part of geotechnical studies for major structures and are an important tool in their design for site specific conditions such as site-specific earthquake response. This paper reported on a study in which shear wave velocities were measured at a proposed petrochemical plant site near Edmonton, Alberta. The proposed site is underlain by lacustrine clay, glacial till and upper Cretaceous clay shale and sandstone bedrock. The most commonly used methods for determining shear wave velocity include crosshole seismic tests, downhole seismic tests, and seismic cone penetration tests (SCPT). This paper presented the results of all 3 methods used in this study and provided a comparison of the various test methods and their limitations. The crosshole test results demonstrated a common trend of increasing shear wave velocity with depth to about 15 m, below which the velocities remained relatively constant. An anomaly was noted at one site, where the shear wave velocity was reduced at a zone corresponding to clay till containing stiff high plastic clay layers. The field study demonstrated that reasonable agreement in shear wave velocity measurements can be made using crosshole, downhole and seismic tests in the same soil conditions. The National Building Code states that the shear wave velocity is the fundamental method for determining site classification, thus emphasizing the importance of obtaining shear wave velocity measurements for site classification. It was concluded that an SCPT program can be incorporated into the field program without much increase in cost and can be supplemented by downhole or crosshole techniques. 5 refs., 2 tabs., 10 figs.

  4. Lactose tolerance tests

    Science.gov (United States)

    Hydrogen breath test for lactose tolerance ... Two common methods include: Lactose tolerance blood test Hydrogen breath test The hydrogen breath test is the preferred method. It measures the amount of hydrogen ...

  5. [Inappropriate test methods in allergy].

    Science.gov (United States)

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  6. 30 CFR 36.41 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 36.41 Section 36.41 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Requirements § 36.41 Testing methods. Mobile diesel-powered transportation equipment submitted for...

  7. Comparison of Methods for Adjusting Incorrect Assignments of Items to Subtests Oblique Multiple Group Method Versus Confirmatory Common Factor Method

    NARCIS (Netherlands)

    Stuive, Ilse; Kiers, Henk A.L.; Timmerman, Marieke E.

    2009-01-01

    A common question in test evaluation is whether an a priori assignment of items to subtests is supported by empirical data. If the analysis results indicate the assignment of items to subtests under study is not supported by data, the assignment is often adjusted. In this study the authors compare

  8. An electron moiré method for a common SEM

    Institute of Scientific and Technical Information of China (English)

    Y.M.Xing; S.Kishimoto; Y.R.Zhao

    2006-01-01

    In the electron moiré method,a high-frequency grating is used to measure microscopic deformation,which promises significant potential applications for the method in the microscopic analysis of materials.However,a special beam scanning control device is required to produce a grating and generate a moiré fringe pattern for the scanning electron microscope (SEM).Because only a few SEMs used in the material science studies are equipped with this device,the use of the electron moiré method is limited.In this study,an electron moiré method for a common SEM without the beam control device is presented.A grating based on a multi-scanning concept is fabricated in any observing mode.A real-time moiré pattern can also be generated in the SEM or an optical filtering system.Without the beam control device being a prerequisite,the electron moiré method can be more widely used.The experimental results from three different types of SEMS show that high quality gratings with uniform lines and less pitch error can be fabricated by this method,and moiré patterns can also be correctly generated.

  9. "Tension" in South Asian women: developing a measure of common mental disorder using participatory methods.

    Science.gov (United States)

    Karasz, Alison; Patel, Viraj; Kabita, Mahbhooba; Shimu, Parvin

    2013-01-01

    Although common mental disorder (CMD) is highly prevalent among South Asian immigrant women, they rarely seek mental treatment. This may be owing in part to the lack of conceptual synchrony between medical models of mental disorder and the social models of distress common in South Asian communities. Furthermore, common mental health screening and diagnostic measures may not adequately capture distress in this group. Community-based participatory research (CBPR) is ideally suited to help address measurement issues in CMD as well as to develop culturally appropriate treatment models. To use participatory methods to identify an appropriate, culturally specific mental health syndrome and develop an instrument to measure this syndrome. We formed a partnership between researchers, clinicians, and community members. The partnership selected a culturally specific model of emotional distress/illness, "tension," as a focus for further study. Partners developed a scale to measure Tension and tested the new scale on 162 Bangladeshi immigrant women living in the Bronx. The 24-item "Tension Scale" had high internal consistency (α = 0.83). On bivariate analysis, the scale significantly correlated in the expected direction with depressed as measured by the Patient Health Questionnaire (PHQ-2), age, education, self-rated health, having seen a physician in the past year, and other variables. Using participatory techniques, we created a new measure designed to assess CMD in an isolated immigrant group. The new measure shows excellent psychometric properties and will be helpful in the implementation of a community-based, culturally synchronous intervention for depression. We describe a useful strategy for the rapid development and field testing of culturally appropriate measures of mental distress and disorder.

  10. A multi-frequency fatigue testing method for wind turbine rotor blades

    Science.gov (United States)

    Eder, M. A.; Belloni, F.; Tesauro, A.; Hanis, T.

    2017-02-01

    Rotor blades are among the most delicate components of modern wind turbines. Reliability is a crucial aspect, since blades shall ideally remain free of failure under ultra-high cycle loading conditions throughout their designated lifetime of 20-25 years. Full-scale blade tests are the most accurate means to experimentally simulate damage evolution under operating conditions, and are therefore used to demonstrate that a blade type fulfils the reliability requirements to an acceptable degree of confidence. The state-of-the-art testing method for rotor blades in industry is based on resonance excitation where typically a rotating mass excites the blade close to its first natural frequency. During operation the blade response due to external forcing is governed by a weighted combination of its eigenmodes. Current test methodologies which only utilise the lowest eigenfrequency induce a fictitious damage where additional tuning masses are required to recover the desired damage distribution. Even with the commonly adopted amplitude upscaling technique fatigue tests remain a time-consuming and costly endeavour. The application of tuning masses increases the complexity of the problem by lowering the natural frequency of the blade and therefore increasing the testing time. The novel method presented in this paper aims at shortening the duration of the state-of-the-art fatigue testing method by simultaneously exciting the blade with a combination of two or more eigenfrequencies. Taking advantage of the different shapes of the excited eigenmodes, the actual spatial damage distribution can be more realistically simulated in the tests by tuning the excitation force amplitudes rather than adding tuning masses. This implies that in portions of the blade the lowest mode is governing the damage whereas in others higher modes contribute more significantly due to their higher cycle count. A numerical feasibility study based on a publicly available large utility rotor blade is used to

  11. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  12. An intuitive method to automatically detect the common and not common frequencies for two or more time-varying signals

    International Nuclear Information System (INIS)

    Doca, C.; Paunoiu, C.; Doca, L.

    2013-01-01

    Sampling a time-varying signal and his spectral analysis are, both, subjected to theoretically compelling, such as Shannon's theorem and the objectively limiting of the frequencys resolution. After obtaining the signals (Fourier) spectrum, this is processed and interpreted usually by a scientist who, presumably, has sufficient prior information about the monitored signal to conclude, for example, on the significant frequencies. Obviously, processing and interpretation of individual spectra are routine tasks that can be automated by suitable software (PC application). The problems complicate if we need to compare two or more spectra corresponding to different signals and/or phenomena. In the above context, this paper presents an intuitive method for automatic identification of the common and not common frequencies for two or more congruent spectra. The method is illustrated by numerical simulations, and by the results obtained in the analysis of the noise from some experimental measured signals. (authors)

  13. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  14. Development of Dissolution Test Method for Drotaverine ...

    African Journals Online (AJOL)

    Development of Dissolution Test Method for Drotaverine ... Methods: Sink conditions, drug stability and specificity in different dissolution media were tested to optimize a dissolution test .... test by Prism 4.0 software, and differences between ...

  15. Two-step nuclear reactions: The Surrogate Method, the Trojan Horse Method and their common foundations

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Mahir S. [DCTA, Instituto Tecnologico de Aeronautica, Sao Jose dos Campos, SP (Brazil); Universidade de Sao Paulo, Instituto de Estudos Avancados, C. P. 72012, Sao Paulo, SP (Brazil); Universidade de Sao Paulo, Instituto de Fisica, C. P. 66318, Sao Paulo, SP (Brazil)

    2017-05-15

    In this Letter I argue that the Surrogate Method, used to extract the fast neutron capture cross section on actinide target nuclei, which has important practical application for the next generation of breeder reactors, and the Trojan Horse Method employed to extract reactions of importance to nuclear astrophysics, have a common foundation, the Inclusive Non-Elastic Breakup (INEB) Theory. Whereas the Surrogate Method relies on the premise that the extracted neutron cross section in a (d, p) reaction is predominantly a compound-nucleus one, the Trojan Horse Method assumes a predominantly direct process for the secondary reaction induced by the surrogate fragment. In general, both methods contain both direct and compound contributions, and I show how these seemingly distinct methods are in fact the same but at different energies and different kinematic regions. The unifying theory is the rather well developed INEB theory. (orig.)

  16. Two-step nuclear reactions: The Surrogate Method, the Trojan Horse Method and their common foundations

    International Nuclear Information System (INIS)

    Hussein, Mahir S.

    2017-01-01

    In this Letter I argue that the Surrogate Method, used to extract the fast neutron capture cross section on actinide target nuclei, which has important practical application for the next generation of breeder reactors, and the Trojan Horse Method employed to extract reactions of importance to nuclear astrophysics, have a common foundation, the Inclusive Non-Elastic Breakup (INEB) Theory. Whereas the Surrogate Method relies on the premise that the extracted neutron cross section in a (d, p) reaction is predominantly a compound-nucleus one, the Trojan Horse Method assumes a predominantly direct process for the secondary reaction induced by the surrogate fragment. In general, both methods contain both direct and compound contributions, and I show how these seemingly distinct methods are in fact the same but at different energies and different kinematic regions. The unifying theory is the rather well developed INEB theory. (orig.)

  17. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  18. The Implementation of APIQ Creative Mathematics Game Method in the Subject Matter of Greatest Common Factor and Least Common Multiple in Elementary School

    Science.gov (United States)

    Rahman, Abdul; Saleh Ahmar, Ansari; Arifin, A. Nurani M.; Upu, Hamzah; Mulbar, Usman; Alimuddin; Arsyad, Nurdin; Ruslan; Rusli; Djadir; Sutamrin; Hamda; Minggi, Ilham; Awi; Zaki, Ahmad; Ahmad, Asdar; Ihsan, Hisyam

    2018-01-01

    One of causal factors for uninterested feeling of the students in learning mathematics is a monotonous learning method, like in traditional learning method. One of the ways for motivating students to learn mathematics is by implementing APIQ (Aritmetika Plus Intelegensi Quantum) creative mathematics game method. The purposes of this research are (1) to describe students’ responses toward the implementation of APIQ creative mathematics game method on the subject matter of Greatest Common Factor (GCF) and Least Common Multiple (LCM) and (2) to find out whether by implementing this method, the student’s learning completeness will improve or not. Based on the results of this research, it is shown that the responses of the students toward the implementation of APIQ creative mathematics game method in the subject matters of GCF and LCM were good. It is seen in the percentage of the responses were between 76-100%. (2) The implementation of APIQ creative mathematics game method on the subject matters of GCF and LCM improved the students’ learning.

  19. A reproducible accelerated in vitro release testing method for PLGA microspheres.

    Science.gov (United States)

    Shen, Jie; Lee, Kyulim; Choi, Stephanie; Qu, Wen; Wang, Yan; Burgess, Diane J

    2016-02-10

    The objective of the present study was to develop a discriminatory and reproducible accelerated in vitro release method for long-acting PLGA microspheres with inner structure/porosity differences. Risperidone was chosen as a model drug. Qualitatively and quantitatively equivalent PLGA microspheres with different inner structure/porosity were obtained using different manufacturing processes. Physicochemical properties as well as degradation profiles of the prepared microspheres were investigated. Furthermore, in vitro release testing of the prepared risperidone microspheres was performed using the most common in vitro release methods (i.e., sample-and-separate and flow through) for this type of product. The obtained compositionally equivalent risperidone microspheres had similar drug loading but different inner structure/porosity. When microsphere particle size appeared similar, porous risperidone microspheres showed faster microsphere degradation and drug release compared with less porous microspheres. Both in vitro release methods investigated were able to differentiate risperidone microsphere formulations with differences in porosity under real-time (37 °C) and accelerated (45 °C) testing conditions. Notably, only the accelerated USP apparatus 4 method showed good reproducibility for highly porous risperidone microspheres. These results indicated that the accelerated USP apparatus 4 method is an appropriate fast quality control tool for long-acting PLGA microspheres (even with porous structures). Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  1. 40 CFR 63.465 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.465 Section 63.465... Halogenated Solvent Cleaning § 63.465 Test methods. (a) Except as provided in paragraphs (f) and (g) of this... Reference Method 307 in appendix A of this part. (b) Except as provided in paragraph (g) of this section for...

  2. The Prevalence of Common Mental Disorders Among South Africans Seeking HIV Testing.

    Science.gov (United States)

    Kagee, Ashraf; Saal, Wylene; De Villiers, Laing; Sefatsa, Mpho; Bantjes, Jason

    2017-06-01

    We administered the Structured Clinical Interview for the DSM to 485 persons seeking HIV testing at five community testing centres in South Africa to determine the prevalence of common mental disorders among this population. The prevalence estimates for the various disorders were as follows: major depressive disorder: 14.2 % (95 % CI [11.1, 17.3]); generalised anxiety disorder 5.0 % (95 % CI [3.07, 6.93]); posttraumatic stress disorder 4.9 % (95 % CI [2.98, 6.82]); and alcohol use disorder 19.8 % (95 % CI [16.26, 23.34]). Our findings imply the need to research the integration of screening and referral trajectories in the context of voluntary HIV counselling and testing.

  3. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Reliability Quantification Method for Safety Critical Software Based on a Finite Test Set

    International Nuclear Information System (INIS)

    Shin, Sung Min; Kim, Hee Eun; Kang, Hyun Gook; Lee, Seung Jun

    2014-01-01

    Software inside of digitalized system have very important role because it may cause irreversible consequence and affect the whole system as common cause failure. However, test-based reliability quantification method for some safety critical software has limitations caused by difficulties in developing input sets as a form of trajectory which is series of successive values of variables. To address these limitations, this study proposed another method which conduct the test using combination of single values of variables. To substitute the trajectory form of input using combination of variables, the possible range of each variable should be identified. For this purpose, assigned range of each variable, logical relations between variables, plant dynamics under certain situation, and characteristics of obtaining information of digital device are considered. A feasibility of the proposed method was confirmed through an application to the Reactor Protection System (RPS) software trip logic

  5. 40 CFR 59.207 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...

  6. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  7. Test Methods for Robot Agility in Manufacturing.

    Science.gov (United States)

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  8. Planar quadrature RF transceiver design using common-mode differential-mode (CMDM transmission line method for 7T MR imaging.

    Directory of Open Access Journals (Sweden)

    Ye Li

    Full Text Available The use of quadrature RF magnetic fields has been demonstrated to be an efficient method to reduce transmit power and to increase the signal-to-noise (SNR in magnetic resonance (MR imaging. The goal of this project was to develop a new method using the common-mode and differential-mode (CMDM technique for compact, planar, distributed-element quadrature transmit/receive resonators for MR signal excitation and detection and to investigate its performance for MR imaging, particularly, at ultrahigh magnetic fields. A prototype resonator based on CMDM method implemented by using microstrip transmission line was designed and fabricated for 7T imaging. Both the common mode (CM and the differential mode (DM of the resonator were tuned and matched at 298MHz independently. Numerical electromagnetic simulation was performed to verify the orthogonal B1 field direction of the two modes of the CMDM resonator. Both workbench tests and MR imaging experiments were carried out to evaluate the performance. The intrinsic decoupling between the two modes of the CMDM resonator was demonstrated by the bench test, showing a better than -36 dB transmission coefficient between the two modes at resonance frequency. The MR images acquired by using each mode and the images combined in quadrature showed that the CM and DM of the proposed resonator provided similar B1 coverage and achieved SNR improvement in the entire region of interest. The simulation and experimental results demonstrate that the proposed CMDM method with distributed-element transmission line technique is a feasible and efficient technique for planar quadrature RF coil design at ultrahigh fields, providing intrinsic decoupling between two quadrature channels and high frequency capability. Due to its simple and compact geometry and easy implementation of decoupling methods, the CMDM quadrature resonator can possibly be a good candidate for design blocks in multichannel RF coil arrays.

  9. Development of a magnet power supply with sub-ppm ripple performance for J-PARC with a novel common-mode rejection method with an NPC inverter

    International Nuclear Information System (INIS)

    Koseki, K.; Kurimoto, Y.

    2014-01-01

    The mechanism that generates common-mode noise in inverter circuits, which are widely used in magnet power supplies, was evaluated by a circuit simulation. By following asymmetric operational sequences, pulsed voltage is applied to the parasitic capacitance of power cables that causes a common-mode current at each switching period of the semiconductor switches. Common-mode noise was also found to disturb the normal-mode excitation current by inducing higher frequency components in the applied voltage to the magnet. To eliminate the disturbing effect by the common-mode noise, a newly developed operational method that uses a neutral point clamped, NPC, inverter with reduced switching sequences was evaluated both by a circuit simulation and experimentally. The operational method for the NPC inverter could sufficiently reduce the common-mode noise. A high-power test operation performed using 16 bending magnets at the J-PARC facility achieved a ripple of less than 1 ppm in the excitation current

  10. Development of a magnet power supply with sub-ppm ripple performance for J-PARC with a novel common-mode rejection method with an NPC inverter

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, K., E-mail: kunio.koseki@kek.jp; Kurimoto, Y.

    2014-05-21

    The mechanism that generates common-mode noise in inverter circuits, which are widely used in magnet power supplies, was evaluated by a circuit simulation. By following asymmetric operational sequences, pulsed voltage is applied to the parasitic capacitance of power cables that causes a common-mode current at each switching period of the semiconductor switches. Common-mode noise was also found to disturb the normal-mode excitation current by inducing higher frequency components in the applied voltage to the magnet. To eliminate the disturbing effect by the common-mode noise, a newly developed operational method that uses a neutral point clamped, NPC, inverter with reduced switching sequences was evaluated both by a circuit simulation and experimentally. The operational method for the NPC inverter could sufficiently reduce the common-mode noise. A high-power test operation performed using 16 bending magnets at the J-PARC facility achieved a ripple of less than 1 ppm in the excitation current.

  11. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    8933 Com (661) 277 8933 email jon.morgan.2.ctr@us.af.mil Secretariat, Range Commanders Council ATTN: TEDT-WS-RCC 1510 Headquarters Avenue White...Sands Missile Range, New Mexico 88002-5110 Phone: DSN 258-1107 Com (575) 678-1107 Fax: DSN 258-7519 Com (575) 678-7519 email ...Method for Testing Syntax The test method is as follows. 1. Initialize the programming environment. 2. Write test application code to use the

  12. Analysis of unbalanced sensor in eddy current method of non destructive testing

    International Nuclear Information System (INIS)

    Chegodaev, V.V.

    2001-01-01

    Different types of sensors are used in eddy current method of non-destructive testing. The choosing of sensor type depends on control object. Different types of sensors can have the same schemes of cut-in in device for formation of information signal. The most common scheme of sensor cut-in is presented. The calculation of output voltage when the sensor is on a segment of the control object, which has not defect is made. The conditions of balancing are adduced and it was shown that the balancing of sensor is very difficult. The methods of compensation or account of voltage of an imbalance are indicated. (author)

  13. ANA Testing: What should we know about the methods, indication and interpretation?

    Directory of Open Access Journals (Sweden)

    Au Elaine Yuen Ling

    2017-11-01

    Full Text Available Though ANA is a common test requested in several settings, one may not be aware of the potential traps for interpretation. Nowadays, there is a trend for autoantibodies diagnostics to move from traditional time honored manual methods to high throughput automated platforms. Nevertheless, the clinical significance and assay performance characteristics may be different from those “historical” methods. Though indirect immunofluorescence is the gold standard method for ANA tests, different laboratories vary in the slides (from different cell lines and commercial source, e.g., Hep 2, Hep 2000, etc., screening dilutions, terminology, reporting format and expertise. Hence, discrepancy in results among different laboratories is not uncommon and could be confusing. Knowing the assay characteristic and limitations helps proper results interpretation and facilitate patient’s management. Indeed, the titer and pattern by indirect immunofluorescence do provide valuable information in screening patients. In particular, DFS pattern with the associated anti-DFS70 antibodies has been shown to have a role to risk stratify cases referred for suspected autoimmune rheumatic disease.

  14. Test of a mosquito eggshell isolation method and subsampling procedure.

    Science.gov (United States)

    Turner, P A; Streever, W J

    1997-03-01

    Production of Aedes vigilax, the common salt-marsh mosquito, can be assessed by determining eggshell densities found in soil. In this study, 14 field-collected eggshell samples were used to test a subsampling technique and compare eggshell counts obtained with a flotation method to those obtained by direct examination of sediment (DES). Relative precision of the subsampling technique was assessed by determining the minimum number of subsamples required to estimate the true mean and confidence interval of a sample at a predetermined confidence level. A regression line was fitted to cube-root transformed eggshell counts obtained from flotation and DES and found to be significant (P eggshells present. Eggshells obtained with the flotation method can be used to predict those from DES using the following equation: DES count = [1.386 x (flotation count)0.33 - 0.01]3.

  15. A Teaching Method on Basic Chemistry for Freshman (II) : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2004-01-01

    This report deals with review of a teaching method on basic chemistry for freshman in this first semester. We tried to review this teaching method with pre-test and post-test by means of the official and private questionnaires. Several hints and thoughts on teaching skills are obtained from this analysis.

  16. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  17. Analysis of protein carbonylation - pitfalls and promise in commonly used methods

    DEFF Research Database (Denmark)

    Rogowska-Wrzesinska, A.; Wojdyla, K.; Nedic, O.

    2014-01-01

    that research scientists are becoming more eager to be able to measure accurately the level of oxidized protein in biological materials, and to determine the precise site of the oxidative attack on the protein, in order to get insights into the molecular mechanisms involved in the progression of diseases....... Several methods for measuring protein carbonylation have been implemented in different laboratories around the world. However, to date no methods prevail as the most accurate, reliable, and robust. The present paper aims at giving an overview of the common methods used to determine protein carbonylation...... in biological material as well as to highlight the limitations and the potential. The ultimate goal is to give quick tips for a rapid decision making when a method has to be selected and taking into consideration the advantage and drawback of the methods....

  18. Analysis of protein carbonylation-pitfalls and promise in commonly used methods

    DEFF Research Database (Denmark)

    Rogowska-Wrzesinska, Adelina; Wojdyla, K; Nedić, O

    2014-01-01

    that research scientists are becoming more eager to be able to measure accurately the level of oxidized protein in biological materials, and to determine the precise site of the oxidative attack on the protein, in order to get insights into the molecular mechanisms involved in the progression of diseases....... Several methods for measuring protein carbonylation have been implemented in different laboratories around the world. However, to date no methods prevail as the most accurate, reliable, and robust. The present paper aims at giving an overview of the common methods used to determine protein carbonylation...... in biological material as well as to highlight the limitations and the potential. The ultimate goal is to give quick tips for a rapid decision making when a method has to be selected and taking into consideration the advantage and drawback of the methods....

  19. Variation of strain rate sensitivity index of a superplastic aluminum alloy in different testing methods

    Science.gov (United States)

    Majidi, Omid; Jahazi, Mohammad; Bombardier, Nicolas; Samuel, Ehab

    2017-10-01

    The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.

  20. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  1. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  2. Validity of Commonly Used Clinical Tests to Diagnose and Screen for Spinal Pain in Adolescents

    DEFF Research Database (Denmark)

    Aartun, Ellen; Hartvigsen, Jan; Hestbaek, Lise

    2016-01-01

    , the area under the receiver operating characteristic curve ranged from 0.60 to 0.65. None of the selected tests could predict incidence cases of neck pain, mid back pain, or low back pain. CONCLUSION: Clinical tests commonly used in spinal screening in adolescents could not detect present spinal pain...... under the receiver operating characteristic curve was calculated for evaluation of all tests combined. RESULTS: The sensitivity was low, and specificity was high for all tests at both baseline (age, 11-13 years) and follow-up (age, 13-15 years). When all tests were evaluated collectively in 1 model...

  3. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximat...... and the sky temperature. Based on the investigations, recommendations for change of the test methods and test conditions are considered. The investigations are carried out within the NEGST (New Generation of Solar Thermal Systems) project financed by EU.......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...... equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approximation determined as a constant equal to the specific heat of the solar collector fluid at the temperature Tm...

  4. Methods for Equating Mental Tests.

    Science.gov (United States)

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...three IRT equating methods were examined in this study; two sections of TOEFL were each (separately) equated. The IRT methods included the following: (a...group. A separate base form was established for each of the six equating methods. Instead of equating the base-form TOEFL to itself, the last (eighth

  5. Effects of common chronic medical conditions on psychometric tests used to diagnose minimal hepatic encephalopathy

    DEFF Research Database (Denmark)

    Lauridsen, M M; Poulsen, L; Rasmussen, C K

    2016-01-01

    Many chronic medical conditions are accompanied by cognitive disturbances but these have only to a very limited extent been psychometrically quantified. An exception is liver cirrhosis where hepatic encephalopathy is an inherent risk and mild forms are diagnosed by psychometric tests. The preferred...... diagnostic test battery in cirrhosis is often the Continuous Reaction Time (CRT) and the Portosystemic Encephalopathy (PSE) tests but the effect on these of other medical conditions is not known. We aimed to examine the effects of common chronic (non-cirrhosis) medical conditions on the CRT and PSE tests. We...

  6. Standard Test Method for Measuring Heat Flux Using Flush-Mounted Insert Temperature-Gradient Gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes the measurement of the net heat flux normal to a surface using gages inserted flush with the surface. The geometry is the same as heat-flux gages covered by Test Method E 511, but the measurement principle is different. The gages covered by this standard all use a measurement of the temperature gradient normal to the surface to determine the heat that is exchanged to or from the surface. Although in a majority of cases the net heat flux is to the surface, the gages operate by the same principles for heat transfer in either direction. 1.2 This general test method is quite broad in its field of application, size and construction. Two different gage types that are commercially available are described in detail in later sections as examples. A summary of common heat-flux gages is given by Diller (1). Applications include both radiation and convection heat transfer. The gages used for aerospace applications are generally small (0.155 to 1.27 cm diameter), have a fast time response ...

  7. A review of common methods to convert morphine to methadone

    Directory of Open Access Journals (Sweden)

    Eric Wong

    2013-01-01

    Full Text Available When dosed appropriately on carefully chosen patients, methadone can be a very safe and effective choice in managing chronic pain. Many authors have discussed important issues surrounding patient selection, drug interactions, screening for QTc prolongation and monitoring. This article will focus on the dosing dilemma that exists after the patient is deemed an appropriate candidate for methadone and a conversion is necessary from another opioid. Despite many publications dedicated to addressing this challenging topic, there is no consensus on the most appropriate method for converting an opioid regimen to methadone. Given the lack of concrete guidance, clinicians in a community setting are likely to be faced with an increased challenge if there are no available pain specialists to provide clinical support. Common methods for converting morphine to methadone will be reviewed and two clinical patient scenarios used to illustrate the outcomes of applying the methods.

  8. Thermal test requirements and their verification by different test methods

    International Nuclear Information System (INIS)

    Droste, B.; Wieser, G.; Probst, U.

    1993-01-01

    The paper discusses the parameters influencing the thermal test conditions for type B-packages. Criteria for different test methods (by analytical as well as by experimental means) will be developed. A comparison of experimental results from fuel oil pool and LPG fire tests will be given. (J.P.N.)

  9. A survey of methods used for antimicrobial susceptibility testing in veterinary diagnostic laboratories in the United States.

    Science.gov (United States)

    Dargatz, David A; Erdman, Matthew M; Harris, Beth

    2017-09-01

    Antimicrobial resistance is a serious threat to animal and human health worldwide, requiring a collaborative, holistic approach. The U.S. Government has developed a national strategy to address antimicrobial resistance, with one component being to monitor antimicrobial resistance in agricultural settings. We developed a survey to collect information about antimicrobial susceptibility testing (AST) from the veterinary diagnostic laboratory community in the United States, assessing current practices and technologies and determining how AST information is shared. Of the 132 surveys administered, 52 (39%) were returned. Overall, responding laboratories conducted susceptibility tests on 98,788 bacterial isolates in 2014, with Escherichia coli being the most common pathogen tested across all animal species. The 2 most common AST methods employed were the disk diffusion method (71%) and the Sensititre platform broth microdilution system (59%). Laboratories primarily used the Clinical Laboratory Standards Institute (CLSI) VET-01 standard (69%) and the automatically calculated interpretations provided by the commercial AST systems (61%) for interpreting their AST data. Only 22% of laboratories published AST data on a periodic basis, usually via annual reports published on the laboratory's website or through peer-reviewed journals for specific pathogens. Our results confirm that disk diffusion and broth microdilution remain the standard AST methods employed by U.S. veterinary diagnostic laboratories, and that CLSI standards are commonly used for interpreting AST results. This information will help determine the most efficient standardized methodology for future surveillance. Furthermore, the current infrastructure within laboratories, once harmonized, will help provide a mechanism for conducting national surveillance programs.

  10. A new method of testing space-based high-energy electron detectors with radioactive electron sources

    Science.gov (United States)

    Zhang, S. Y.; Shen, G. H.; Sun, Y.; Zhou, D. Z.; Zhang, X. X.; Li, J. W.; Huang, C.; Zhang, X. G.; Dong, Y. J.; Zhang, W. J.; Zhang, B. Q.; Shi, C. Y.

    2016-05-01

    Space-based electron detectors are commonly tested using radioactive β-sources which emit a continuous spectrum without spectral lines. Therefore, the tests are often to be considered only qualitative. This paper introduces a method, which results in more than a qualitative test even when using a β-source. The basic idea is to use the simulated response function of the instrument to invert the measured spectrum and compare this inverted spectrum with a reference spectrum obtained from the same source. Here we have used Geant4 to simulate the instrument response function (IRF) and a 3.5 mm thick Li-drifted Si detector to obtain the reference 90Sr/90Yi source spectrum to test and verify the geometric factors of the Omni-Direction Particle Detector (ODPD) on the Tiangong-1 (TG-1) and Tiangong-2 (TG-2) spacecraft. The TG spacecraft are experimental space laboratories and prototypes of the Chinese space station. The excellent agreement between the measured and reference spectra demonstrates that this test method can be used to quantitatively assess the quality of the instrument. Due to its simplicity, the method is faster and therefore more efficient than traditional full calibrations using an electron accelerator.

  11. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1993-01-01

    This report documents progress to date under a three-year contract for developing ''Methods for Testing Transport Models.'' The work described includes (1) choice of best methods for producing ''code emulators'' for analysis of very large global energy confinement databases, (2) recent applications of stratified regressions for treating individual measurement errors as well as calibration/modeling errors randomly distributed across various tokamaks, (3) Bayesian methods for utilizing prior information due to previous empirical and/or theoretical analyses, (4) extension of code emulator methodology to profile data, (5) application of nonlinear least squares estimators to simulation of profile data, (6) development of more sophisticated statistical methods for handling profile data, (7) acquisition of a much larger experimental database, and (8) extensive exploratory simulation work on a large variety of discharges using recently improved models for transport theories and boundary conditions. From all of this work, it has been possible to define a complete methodology for testing new sets of reference transport models against much larger multi-institutional databases

  12. A Quantitative Method to Screen Common Bean Plants for Resistance to Bean common mosaic necrosis virus.

    Science.gov (United States)

    Strausbaugh, C A; Myers, J R; Forster, R L; McClean, P E

    2003-11-01

    ABSTRACT A quantitative method to screen common bean (Phaseolus vulgaris) plants for resistance to Bean common mosaic necrosis virus (BCMNV) is described. Four parameters were assessed in developing the quantitative method: symptoms associated with systemic virus movement, plant vigor, virus titer, and plant dry weight. Based on these parameters, two rating systems (V and VV rating) were established. Plants from 21 recombinant inbred lines (RILs) from a Sierra (susceptible) x Olathe (partially resistant) cross inoculated with the BCMNV-NL-3 K strain were used to evaluate this quantitative approach. In all, 11 RILs exhibited very susceptible reactions and 10 RILs expressed partially resistant reactions, thus fitting a 1:1 susceptible/partially resistant ratio (chi(2) = 0.048, P = 0.827) and suggesting that the response is mediated by a single gene. Using the classical qualitative approach based only on symptom expression, the RILs were difficult to separate into phenotypic groups because of a continuum of responses. By plotting mean percent reduction in either V (based on visual symptoms) or VV (based on visual symptoms and vigor) rating versus enzyme-linked immunosorbent assay (ELISA) absorbance values, RILs could be separated clearly into different phenotypic groups. The utility of this quantitative approach also was evaluated on plants from 12 cultivars or pure lines inoculated with one of three strains of BCMNV. Using the mean VV rating and ELISA absorbance values, significant differences were established not only in cultivar and pure line comparisons but also in virus strain comparisons. This quantitative system should be particularly useful for the evaluation of the independent action of bc genes, the discovery of new genes associated with partial resistance, and assessing virulence of virus strains.

  13. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  14. Alternative Test Method for Olefins in Gasoline

    Science.gov (United States)

    This action proposes to allow for an additional alternative test method for olefins in gasoline, ASTM D6550-05. The allowance of this additional alternative test method will provide more flexibility to the regulated industry.

  15. Correlation of geotextile puncture test methods : research brief.

    Science.gov (United States)

    2017-05-01

    Geotextiles are commonly used in pavements, earth retaining structures, landfills and other geotechnical contexts. Various tests are conducted to evaluate and classify geotextiles to determine their suitability for each of these applications. The AST...

  16. A strategy to discover genes that carry multi-allelic or mono-allelic risk for common diseases: A cohort allelic sums test (CAST)

    International Nuclear Information System (INIS)

    Morgenthaler, Stephan; Thilly, William G.

    2007-01-01

    A method is described to discover if a gene carries one or more allelic mutations that confer risk for any specified common disease. The method does not depend upon genetic linkage of risk-conferring mutations to high frequency genetic markers such as single nucleotide polymorphisms. Instead, the sums of allelic mutation frequencies in case and control cohorts are determined and a statistical test is applied to discover if the difference in these sums is greater than would be expected by chance. A statistical model is presented that defines the ability of such tests to detect significant gene-disease relationships as a function of case and control cohort sizes and key confounding variables: zygosity and genicity, environmental risk factors, errors in diagnosis, limits to mutant detection, linkage of neutral and risk-conferring mutations, ethnic diversity in the general population and the expectation that among all exonic mutants in the human genome greater than 90% will be neutral with regard to any effect on disease risk. Means to test the null hypothesis for, and determine the statistical power of, each test are provided. For this 'cohort allelic sums test' or 'CAST', the statistical model and test are provided as an Excel (TM) program, CASTAT (C) at http://epidemiology.mit.edu. Based on genetics, technology and statistics, a strategy of enumerating the mutant alleles carried in the exons and splice sites of the estimated ∼25,000 human genes in case cohort samples of 10,000 persons for each of 100 common diseases is proposed and evaluated: A wide range of possible conditions of multi-allelic or mono-allelic and monogenic, multigenic or polygenic (including epistatic) risk are found to be detectable using the statistical criteria of 1 or 10 ''false positive'' gene associations per 25,000 gene-disease pair-wise trials and a statistical power of >0.8. Using estimates of the distribution of both neutral and gene-inactivating nondeleterious mutations in humans and

  17. HIV Testing and Care in Canadian Aboriginal Youth: A community based mixed methods study

    Directory of Open Access Journals (Sweden)

    Myers Ted

    2008-10-01

    Full Text Available Abstract Background HIV infection is a serious concern in the Canadian Aboriginal population, particularly among youth; however, there is limited attention to this issue in research literature. The purpose of this national study was to explore HIV testing and care decisions of Canadian Aboriginal youth. Methods A community-based mixed-method design incorporating the Aboriginal research principles of Ownership, Control, Access and Possession (OCAP was used. Data were collected through surveys (n = 413 and qualitative interviews (n = 28. Eleven community-based organizations including urban Aboriginal AIDS service organizations and health and friendship centres in seven provinces and one territory assisted with the recruitment of youth (15 to 30 years. Results Average age of survey participants was 21.5 years (median = 21.0 years and qualitative interview participants was 24.4 years (median = 24.0. Fifty-one percent of the survey respondents (210 of 413 youth and 25 of 28 interview participants had been tested for HIV. The most common reason to seek testing was having sex without a condom (43.6% or pregnancy (35.4% while common reasons for not testing were the perception of being low HIV risk (45.3% or not having had sex with an infected person (34.5%. Among interviewees, a contributing reason for not testing was feeling invulnerable. Most surveyed youth tested in the community in which they lived (86.5% and 34.1% visited a physician for the test. The majority of surveyed youth (60.0% had tested once or twice in the previous 2 years, however, about one-quarter had tested more than twice. Among the 26 surveyed youth who reported that they were HIV-positive, 6 (23.1% had AIDS at the time of diagnosis. Delays in care-seeking after diagnosis varied from a few months to seven years from time of test. Conclusion It is encouraging that many youth who had tested for HIV did so based on a realistic self-assessment of HIV risk behaviours; however, for others

  18. Evaluation of Two Methods for Modeling Measurement Errors When Testing Interaction Effects with Observed Composite Scores

    Science.gov (United States)

    Hsiao, Yu-Yu; Kwok, Oi-Man; Lai, Mark H. C.

    2018-01-01

    Path models with observed composites based on multiple items (e.g., mean or sum score of the items) are commonly used to test interaction effects. Under this practice, researchers generally assume that the observed composites are measured without errors. In this study, we reviewed and evaluated two alternative methods within the structural…

  19. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  20. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  1. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  2. Common Allergens Identified Based on Patch Test Results in Patients with Suspected Contact Dermatitis of the Scalp.

    Science.gov (United States)

    Aleid, Nouf M; Fertig, Raymond; Maddy, Austin; Tosti, Antonella

    2017-03-01

    Contact dermatitis of the scalp is common and might be caused by many chemicals including metals, ingredients of shampoos and conditioners, dyes, or other hair treatments. Eliciting a careful history and patch tests are necessary to identify the responsible allergen and prevent relapses. To identify allergens that may cause contact dermatitis of the scalp by reviewing patch test results. We reviewed the records of 1,015 patients referred for patch testing at the Dermatology Department of the University of Miami. A total of 226 patients (205 females and 21 males) with suspected scalp contact dermatitis were identified, and the patch test results and clinical data for those patients were analyzed. Most patients were referred for patch testing from a specialized hair clinic at our institution. The most common allergens in our study population were nickel (23.8%), cobalt (21.0%), balsam of Peru (18.2%), fragrance mix (14.4%), carba mix (11.6%), and propylene glycol (PG) (8.8%). The majority of patients were females aged 40-59 years, and scalp itching or burning were reported as the most common symptom. Frequent sources of allergens for metals include hair clasps, pins, and brushes, while frequent sources of allergens for preservatives, fragrance mix, and balsam of Peru include shampoos, conditioners, and hair gels. Frequent sources of allergens for PG include topical medications.

  3. Test-retest reliability of Common Mental Disorders Questionnaire (CMDQ) in patients with total hip replacement (THR)

    DEFF Research Database (Denmark)

    Bilberg, Randi; Nørgaard, Birgitte; Roessler, Kirsten Kaya

    2014-01-01

    BACKGROUND: The Common Mental Disorders Questionnaire (CMDQ) is used to assess patients' mental health. It has previously been shown to provide a sensitive and specific instrument for general practitioner setting but has so far not been tested in hospital setting or for changes over time (test....... TRIAL REGISTRATION: Current Controlled Trials: NCT01205295....

  4. Cathodic Delamination Accelerated Life Test Method

    National Research Council Canada - National Science Library

    Ramotowski, Thomas S

    2007-01-01

    A method for conducting an accelerated life test of a polymer coated metallic sample includes placing the sample below the water surface in a test tank containing water and an oxygen containing gas...

  5. 41 CFR 301-72.1 - Why is common carrier presumed to be the most advantageous method of transportation?

    Science.gov (United States)

    2010-07-01

    ... presumed to be the most advantageous method of transportation? 301-72.1 Section 301-72.1 Public Contracts... Transportation § 301-72.1 Why is common carrier presumed to be the most advantageous method of transportation? Travel by common carrier is presumed to be the most advantageous method of transportation because it...

  6. Further Experiments with Lok-Test and Ultrasonic Test in Relation to Fresh and Hardened Concrete

    DEFF Research Database (Denmark)

    Jensen, Jens Kristian Jehrbo

    Lok-test is mainly a non-destructive pull-out test for determination of concrete strength. The method is deseribed in (l) and it is detailed discussed in theory (2). The method is welknown in practice. Ultrasonic is commonly used for investigations of several materials, especially concrete. In a ....... In a project (3) about non-destructive testing of concrete different methods and the relations to concrete are discussed in theory and practice. This paper point out some interesting results from further experiments in this area.......Lok-test is mainly a non-destructive pull-out test for determination of concrete strength. The method is deseribed in (l) and it is detailed discussed in theory (2). The method is welknown in practice. Ultrasonic is commonly used for investigations of several materials, especially concrete...

  7. Test Methods for Telemetry Systems and Subsystems. Volume 2: Test Methods for Telemetry Radio Frequency (RF) Subsystems

    Science.gov (United States)

    2012-09-01

    interference test is to measure the effect on bit error probability ( BEP ) of signals in adjacent frequency slots. The results will be a function of...is to have the two interfering signals 20 dB larger than the victim signal. Vary the attenuator that is common to the two interferers until the BEP ...measurement of bit error probability ( BEP ) improvement (or degradation) when signals are combined as compared with single channel operation. The BEP is

  8. A Novel Transfer Learning Method Based on Common Space Mapping and Weighted Domain Matching

    KAUST Repository

    Liang, Ru-Ze; Xie, Wei; Li, Weizhi; Wang, Hongqi; Wang, Jim Jing-Yan; Taylor, Lisa

    2017-01-01

    In this paper, we propose a novel learning framework for the problem of domain transfer learning. We map the data of two domains to one single common space, and learn a classifier in this common space. Then we adapt the common classifier to the two domains by adding two adaptive functions to it respectively. In the common space, the target domain data points are weighted and matched to the target domain in term of distributions. The weighting terms of source domain data points and the target domain classification responses are also regularized by the local reconstruction coefficients. The novel transfer learning framework is evaluated over some benchmark cross-domain data sets, and it outperforms the existing state-of-the-art transfer learning methods.

  9. A Novel Transfer Learning Method Based on Common Space Mapping and Weighted Domain Matching

    KAUST Repository

    Liang, Ru-Ze

    2017-01-17

    In this paper, we propose a novel learning framework for the problem of domain transfer learning. We map the data of two domains to one single common space, and learn a classifier in this common space. Then we adapt the common classifier to the two domains by adding two adaptive functions to it respectively. In the common space, the target domain data points are weighted and matched to the target domain in term of distributions. The weighting terms of source domain data points and the target domain classification responses are also regularized by the local reconstruction coefficients. The novel transfer learning framework is evaluated over some benchmark cross-domain data sets, and it outperforms the existing state-of-the-art transfer learning methods.

  10. An engineering approach to common mode failure analysis

    International Nuclear Information System (INIS)

    Gangloff, W.C.; Franke, T.H.

    1975-01-01

    Safety systems for nuclear reactors can be designed using standard reliability engineering techniques such that system failure due to random component faults is extremely unlikely. However, the common-mode failure where several components fail together from a common cause is not susceptible to prevention by the usual tactics. In systems where a high degree of redundancy has been employed, the actual reliability of the system in service may be limited by common-mode failures. A methodical and thorough procedure for evaluation of system vulnerability to common-mode failures is presented. This procedure was developed for use in nuclear reactor safety systems and has been applied specifically to reactor protection. The method offers a qualitative assessment of a system whereby weak points can be identified and the resistance to common-mode failure can be judged. It takes into account all factors influencing system performance including design, manufacturing, installation, operation, testing, and maintenance. It is not a guarantee or sure solution, but rather a practical tool which can provide good assurance that the probability of common-mode protection failure has been made acceptably low. (author)

  11. A new method for explicit modelling of single failure event within different common cause failure groups

    International Nuclear Information System (INIS)

    Kančev, Duško; Čepin, Marko

    2012-01-01

    Redundancy and diversity are the main principles of the safety systems in the nuclear industry. Implementation of safety components redundancy has been acknowledged as an effective approach for assuring high levels of system reliability. The existence of redundant components, identical in most of the cases, implicates a probability of their simultaneous failure due to a shared cause—a common cause failure. This paper presents a new method for explicit modelling of single component failure event within multiple common cause failure groups simultaneously. The method is based on a modification of the frequently utilised Beta Factor parametric model. The motivation for development of this method lays in the fact that one of the most widespread softwares for fault tree and event tree modelling as part of the probabilistic safety assessment does not comprise the option for simultaneous assignment of single failure event to multiple common cause failure groups. In that sense, the proposed method can be seen as an advantage of the explicit modelling of common cause failures. A standard standby safety system is selected as a case study for application and study of the proposed methodology. The results and insights implicate improved, more transparent and more comprehensive models within probabilistic safety assessment.

  12. Common fluoroscopic studies in radiology : conduct and analysis method

    International Nuclear Information System (INIS)

    Valverde Sanchez, Allan

    2011-01-01

    A countless number of radiological procedures, that have involved the use of fluoroscopy and contrast media of different indole, have been carried out in all radiology services and medical images of Costa Rica for the diagnosis of diseases or conditions, in both adults and in children. Fluoroscopic studies, often called special or contrast studies, have had particular conditions for its realization. Some from the medical point of view: adequate training in the technical and cognitive development when evaluating the images to not miss important details. Other by the patient: adequate preparation to achieve the best images for optimal diagnosis. For example, adequate bowel preparation is essential for a barium enema, to cooperation by the patient to meet specific indications that the physician dictates when swallowing postures or just when you are prompted. Criteria have been met and unified for contrast studies in different hospitals and clinics. The indications, contra, method, technique of procedure, points to remember, number of images or projections minimum required in the interpretation of contrast studies, as well as a report template of standard and ideal study are presented in a simple, systematic and logical. The manual is intended for residents and attending physicians specialists in radiology and medical imaging including contrast studies more common. Spaces are promoted with current technology studies to set aside more complicated and less sophisticated as have been the fluoroscopic studies; however, in the national reality, access to computerized tomography and magnetic resonance imaging is not as easy. Radiological studies with fluoroscopy performed by trained staff led the treating physician to make sound decisions based on studies relatively simple and easy to do. The tests with the use of fluoroscopic have been named: the esophagogram, gastroduodenal series, gastro intestinal transit, the hysterosalpingography, the cystography and the

  13. A new method of testing space-based high-energy electron detectors with radioactive electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S.Y. [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Shen, G.H., E-mail: shgh@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Sun, Y., E-mail: sunying@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhou, D.Z., E-mail: dazhuang.zhou@gmail.com [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhang, X.X., E-mail: xxzhang@cma.gov.cn [National Center for Space Weather, Beijing (China); Li, J.W., E-mail: lijw@cma.gov.cn [National Center for Space Weather, Beijing (China); Huang, C., E-mail: huangc@cma.gov.cn [National Center for Space Weather, Beijing (China); Zhang, X.G., E-mail: zhangxg@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Dong, Y.J., E-mail: dyj@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhang, W.J., E-mail: zhangreatest@163.com [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Zhang, B.Q., E-mail: zhangbinquan@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China); Shi, C.Y., E-mail: scy@nssc.ac.cn [National Space Science Center, Chinese Academy of Sciences, Beijing (China); Beijing Key Laboratory of Space Environment Exploration, Beijing (China)

    2016-05-01

    Space-based electron detectors are commonly tested using radioactive β-sources which emit a continuous spectrum without spectral lines. Therefore, the tests are often to be considered only qualitative. This paper introduces a method, which results in more than a qualitative test even when using a β-source. The basic idea is to use the simulated response function of the instrument to invert the measured spectrum and compare this inverted spectrum with a reference spectrum obtained from the same source. Here we have used Geant4 to simulate the instrument response function (IRF) and a 3.5 mm thick Li-drifted Si detector to obtain the reference {sup 90}Sr/{sup 90}Yi source spectrum to test and verify the geometric factors of the Omni-Direction Particle Detector (ODPD) on the Tiangong-1 (TG-1) and Tiangong-2 (TG-2) spacecraft. The TG spacecraft are experimental space laboratories and prototypes of the Chinese space station. The excellent agreement between the measured and reference spectra demonstrates that this test method can be used to quantitatively assess the quality of the instrument. Due to its simplicity, the method is faster and therefore more efficient than traditional full calibrations using an electron accelerator.

  14. A new method of testing space-based high-energy electron detectors with radioactive electron sources

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Shen, G.H.; Sun, Y.; Zhou, D.Z.; Zhang, X.X.; Li, J.W.; Huang, C.; Zhang, X.G.; Dong, Y.J.; Zhang, W.J.; Zhang, B.Q.; Shi, C.Y.

    2016-01-01

    Space-based electron detectors are commonly tested using radioactive β-sources which emit a continuous spectrum without spectral lines. Therefore, the tests are often to be considered only qualitative. This paper introduces a method, which results in more than a qualitative test even when using a β-source. The basic idea is to use the simulated response function of the instrument to invert the measured spectrum and compare this inverted spectrum with a reference spectrum obtained from the same source. Here we have used Geant4 to simulate the instrument response function (IRF) and a 3.5 mm thick Li-drifted Si detector to obtain the reference "9"0Sr/"9"0Yi source spectrum to test and verify the geometric factors of the Omni-Direction Particle Detector (ODPD) on the Tiangong-1 (TG-1) and Tiangong-2 (TG-2) spacecraft. The TG spacecraft are experimental space laboratories and prototypes of the Chinese space station. The excellent agreement between the measured and reference spectra demonstrates that this test method can be used to quantitatively assess the quality of the instrument. Due to its simplicity, the method is faster and therefore more efficient than traditional full calibrations using an electron accelerator.

  15. Revealing barriers and facilitators to use a new genetic test: comparison of three user involvement methods.

    Science.gov (United States)

    Rhebergen, Martijn D F; Visser, Maaike J; Verberk, Maarten M; Lenderink, Annet F; van Dijk, Frank J H; Kezic, Sanja; Hulshof, Carel T J

    2012-10-01

    We compared three common user involvement methods in revealing barriers and facilitators from intended users that might influence their use of a new genetic test. The study was part of the development of a new genetic test on the susceptibility to hand eczema for nurses. Eighty student nurses participated in five focus groups (n = 33), 15 interviews (n = 15) or questionnaires (n = 32). For each method, data were collected until saturation. We compared the mean number of items and relevant remarks that could influence the use of the genetic test obtained per method, divided by the number of participants in that method. Thematic content analysis was performed using MAXQDA software. The focus groups revealed 30 unique items compared to 29 in the interviews and 21 in the questionnaires. The interviews produced more items and relevant remarks per participant (1.9 and 8.4 pp) than focus groups (0.9 and 4.8 pp) or questionnaires (0.7 and 2.3 pp). All three involvement methods revealed relevant barriers and facilitators to use a new genetic test. Focus groups and interviews revealed substantially more items than questionnaires. Furthermore, this study suggests a preference for the use of interviews because the number of items per participant was higher than for focus groups and questionnaires. This conclusion may be valid for other genetic tests as well.

  16. Two micro fatigue test methods for irradiated materials

    International Nuclear Information System (INIS)

    Nunomura, Shigetomo; Noguchi, Shinji; Okamura, Yuichi; Kumai, Shinji

    1993-01-01

    This paper demonstrates two miniature fatigue test methods in response to the requirements of the fusion reactor wall materials development program. It is known that the fatigue strength evaluated by the axial loading test is independent of the specimen size, while that evaluated by the bend test or torsion test is dependent upon the size of specimen. The new type of gripping system for the axial, tension-tension, fatigue testing of TEM disk-size specimens that has been developed is described in this paper. An alignment tool assists in gripping the miniature specimen. The miniature tension-tension fatigue test method seems to provide reliable S-N curves for SUS304 and SUS316L stainless steels. An indentation method has also been developed to determine fatigue properties. A hard steel ball or ceramic ball was used for cyclically loading the specimen, and an S-N curve was subsequently obtained. The merit of this method is primarily simple handling. S-N curves obtained from four materials by this indentation method compared well with those obtained from the rotary bend fatigue test employing a standard-size specimen

  17. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Consumption of Central Air Conditioners and Heat Pumps 1. DEFINITIONS 2. TESTING CONDITIONS 2.1Test room... more common ducts within each test room that contains multiple indoor coils. At the plane where each...

  18. Multipath interference test method for distributed amplifiers

    Science.gov (United States)

    Okada, Takahiro; Aida, Kazuo

    2005-12-01

    A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.

  19. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  20. A Bayesian reliability evaluation method with integrated accelerated degradation testing and field information

    International Nuclear Information System (INIS)

    Wang, Lizhi; Pan, Rong; Li, Xiaoyang; Jiang, Tongmin

    2013-01-01

    Accelerated degradation testing (ADT) is a common approach in reliability prediction, especially for products with high reliability. However, oftentimes the laboratory condition of ADT is different from the field condition; thus, to predict field failure, one need to calibrate the prediction made by using ADT data. In this paper a Bayesian evaluation method is proposed to integrate the ADT data from laboratory with the failure data from field. Calibration factors are introduced to calibrate the difference between the lab and the field conditions so as to predict a product's actual field reliability more accurately. The information fusion and statistical inference procedure are carried out through a Bayesian approach and Markov chain Monte Carlo methods. The proposed method is demonstrated by two examples and the sensitivity analysis to prior distribution assumption

  1. Test equating methods and practices

    CERN Document Server

    Kolen, Michael J

    1995-01-01

    In recent years, many researchers in the psychology and statistical communities have paid increasing attention to test equating as issues of using multiple test forms have arisen and in response to criticisms of traditional testing techniques This book provides a practically oriented introduction to test equating which both discusses the most frequently used equating methodologies and covers many of the practical issues involved The main themes are - the purpose of equating - distinguishing between equating and related methodologies - the importance of test equating to test development and quality control - the differences between equating properties, equating designs, and equating methods - equating error, and the underlying statistical assumptions for equating The authors are acknowledged experts in the field, and the book is based on numerous courses and seminars they have presented As a result, educators, psychometricians, professionals in measurement, statisticians, and students coming to the subject for...

  2. A well test analysis method accounting for pre-test operations

    International Nuclear Information System (INIS)

    Silin, D.B.; Tsang, C.-F.

    2003-01-01

    We propose to use regular monitoring data from a production or injection well for estimating the formation hydraulic properties in the vicinity of the wellbore without interrupting the operations. In our approach, we select a portion of the pumping data over a certain time interval and then derive our conclusions from analysis of these data. A distinctive feature of the proposed approach differing it form conventional methods is in the introduction of an additional parameter, an effective pre-test pumping rate. The additional parameter is derived based on a rigorous asymptotic analysis of the flow model. Thus, we account for the non-uniform pressure distribution at the beginning of testing time interval caused by pre-test operations at the well. By synthetic and field examples, we demonstrate that deviation of the matching curve from the data that is usually attributed to skin and wellbore storage effects, can also be interpreted through this new parameter. Moreover, with our method, the data curve is matched equally well and the results of the analysis remain stable when the analyzed data interval is perturbed, whereas traditional methods are sensitive to the choice of the data interval. A special efficient minimization procedure has been developed for searching the best fitting parameters. We enhanced our analysis above with a procedure of estimating ambient reservoir pressure and dimensionless wellbore radius. The methods reported here have been implemented in code ODA (Operations Data Analysis). A beta version of the code is available for free testing and evaluation to interested parties

  3. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  4. The Empirical Verification of an Assignment of Items to Subtests : The Oblique Multiple Group Method Versus the Confirmatory Common Factor Method

    NARCIS (Netherlands)

    Stuive, Ilse; Kiers, Henk A.L.; Timmerman, Marieke E.; ten Berge, Jos M.F.

    2008-01-01

    This study compares two confirmatory factor analysis methods on their ability to verify whether correct assignments of items to subtests are supported by the data. The confirmatory common factor (CCF) method is used most often and defines nonzero loadings so that they correspond to the assignment of

  5. Manned/Unmanned Common Architecture Program (MCAP) net centric flight tests

    Science.gov (United States)

    Johnson, Dale

    2009-04-01

    Properly architected avionics systems can reduce the costs of periodic functional improvements, maintenance, and obsolescence. With this in mind, the U.S. Army Aviation Applied Technology Directorate (AATD) initiated the Manned/Unmanned Common Architecture Program (MCAP) in 2003 to develop an affordable, high-performance embedded mission processing architecture for potential application to multiple aviation platforms. MCAP analyzed Army helicopter and unmanned air vehicle (UAV) missions, identified supporting subsystems, surveyed advanced hardware and software technologies, and defined computational infrastructure technical requirements. The project selected a set of modular open systems standards and market-driven commercial-off-theshelf (COTS) electronics and software, and, developed experimental mission processors, network architectures, and software infrastructures supporting the integration of new capabilities, interoperability, and life cycle cost reductions. MCAP integrated the new mission processing architecture into an AH-64D Apache Longbow and participated in Future Combat Systems (FCS) network-centric operations field experiments in 2006 and 2007 at White Sands Missile Range (WSMR), New Mexico and at the Nevada Test and Training Range (NTTR) in 2008. The MCAP Apache also participated in PM C4ISR On-the-Move (OTM) Capstone Experiments 2007 (E07) and 2008 (E08) at Ft. Dix, NJ and conducted Mesa, Arizona local area flight tests in December 2005, February 2006, and June 2008.

  6. Kidney function tests

    Science.gov (United States)

    Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...

  7. MODERN METHODS OF FOOD INTOLERANCE TESTING

    Directory of Open Access Journals (Sweden)

    M. Yu. Rosensteyn

    2016-01-01

    Full Text Available Аn analytical review of modern methods of food intolerance diagnostics based on interpretation of markers used in the various tests is рresented. It is shown that tests based on observation of the reaction of specific antibodies of the immune system to food antigens tested, are the most accurate, reliable and representative for the diagnosis of food intolerance.

  8. A Method for Generating Educational Test Items That Are Aligned to the Common Core State Standards

    Science.gov (United States)

    Gierl, Mark J.; Lai, Hollis; Hogan, James B.; Matovinovic, Donna

    2015-01-01

    The demand for test items far outstrips the current supply. This increased demand can be attributed, in part, to the transition to computerized testing, but, it is also linked to dramatic changes in how 21st century educational assessments are designed and administered. One way to address this growing demand is with automatic item generation.…

  9. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  10. Functional tests of a prototype for the CMS-ATLAS common non-event data handling framework

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00366910; The ATLAS collaboration; Formica, Andrea

    2017-01-01

    Since 2014 the ATLAS and CMS experiments share a common vision on the database infrastructure for the handling of the non-event data in forthcoming LHC runs. The wide commonality in the use cases has allowed to agree on a common overall design solution that is meeting the requirements of both experiments. A first prototype has been completed in 2016 and has been made available to both experiments. The prototype is based on a web service implementing a REST api with a set of functions for the management of conditions data. In this contribution, we describe this prototype architecture and the tests that have been performed within the CMS computing infrastructure, with the aim of validating the support of the main use cases and of suggesting future improvements.

  11. Common genetic variants associated with cognitive performance identified using the proxy-phenotype method

    NARCIS (Netherlands)

    C.A. Rietveld (Niels); T. Esko (Tõnu); G. Davies (Gail); T.H. Pers (Tune); P. Turley (Patrick); B. Benyamin (Beben); C.F. Chabris (Christopher F.); V. Emilsson (Valur); A.D. Johnson (Andrew); J.J. Lee (James J.); C. de Leeuw (Christiaan); R.E. Marioni (Riccardo); S.E. Medland (Sarah Elizabeth); M. Miller (Mike); O. Rostapshova (Olga); S.J. van der Lee (Sven); A.A.E. Vinkhuyzen (Anna A.); N. Amin (Najaf); D. Conley (Dalton); J. Derringer; C.M. van Duijn (Cornelia); R.S.N. Fehrmann (Rudolf); L. Franke (Lude); E.L. Glaeser (Edward L.); N.K. Hansell (Narelle); C. Hayward (Caroline); W.G. Iacono (William); C.A. Ibrahim-Verbaas (Carla); V.W.V. Jaddoe (Vincent); J. Karjalainen (Juha); D. Laibson (David); P. Lichtenstein (Paul); D.C. Liewald (David C.); P.K. Magnusson (Patrik); N.G. Martin (Nicholas); M. McGue (Matt); G. Mcmahon (George); N.L. Pedersen (Nancy); S. Pinker (Steven); D.J. Porteous (David J.); D. Posthuma (Danielle); F. Rivadeneira Ramirez (Fernando); B.H. Smithk (Blair H.); J.M. Starr (John); H.W. Tiemeier (Henning); N.J. Timpsonm (Nicholas J.); M. Trzaskowskin (Maciej); A.G. Uitterlinden (André); F.C. Verhulst (Frank); M.E. Ward (Mary); M.J. Wright (Margaret); G.D. Smith; I.J. Deary (Ian J.); M. Johannesson (Magnus); R. Plomin (Robert); P.M. Visscher (Peter); D.J. Benjamin (Daniel J.); D. Cesarini (David); Ph.D. Koellinger (Philipp)

    2014-01-01

    textabstractWe identify common genetic variants associated with cognitive performance using a two-stage approach, which we call the proxyphenotype method. First, we conduct a genome-wide association study of educational attainment in a large sample (n = 106,736), which produces a set of 69

  12. A Method to Test Model Calibration Techniques: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, Ron; Polly, Ben; Neymark, Joel

    2016-09-01

    This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

  13. Standard Test Method for Wet Insulation Integrity Testing of Photovoltaic Arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure to determine the insulation resistance of a photovoltaic (PV) array (or its component strings), that is, the electrical resistance between the array's internal electrical components and is exposed, electrically conductive, non-current carrying parts and surfaces of the array. 1.2 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Testing for a Common Volatility Process and Information Spillovers in Bivariate Financial Time Series Models

    NARCIS (Netherlands)

    J. Chen (Jinghui); M. Kobayashi (Masahito); M.J. McAleer (Michael)

    2016-01-01

    textabstractThe paper considers the problem as to whether financial returns have a common volatility process in the framework of stochastic volatility models that were suggested by Harvey et al. (1994). We propose a stochastic volatility version of the ARCH test proposed by Engle and Susmel (1993),

  15. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  16. On sine dwell or broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung; Wada, Ben K.

    1987-01-01

    For large, complex spacecraft structural systems, the objectives of the modal test are outlined. Based on these objectives, the comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantages or disadvantages of each method are examined. The usefulness or shortcoming of the methods are given from a practicing engineer's view point.

  17. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1991-01-01

    Substantial progress has been made over the past year on six aspects of the work supported by this grant. As a result, we have in hand for the first time a fairly complete set of transport models and improved statistical methods for testing them against large databases. We also have initial results of such tests. These results indicate that careful application of presently available transport theories can reasonably well produce a remarkably wide variety of tokamak data

  18. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    Science.gov (United States)

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment

  19. Latency in Visionic Systems: Test Methods and Requirements

    Science.gov (United States)

    Bailey, Randall E.; Arthur, J. J., III; Williams, Steven P.; Kramer, Lynda J.

    2005-01-01

    A visionics device creates a pictorial representation of the external scene for the pilot. The ultimate objective of these systems may be to electronically generate a form of Visual Meteorological Conditions (VMC) to eliminate weather or time-of-day as an operational constraint and provide enhancement over actual visual conditions where eye-limiting resolution may be a limiting factor. Empirical evidence has shown that the total system delays or latencies including the imaging sensors and display systems, can critically degrade their utility, usability, and acceptability. Definitions and measurement techniques are offered herein as common test and evaluation methods for latency testing in visionics device applications. Based upon available data, very different latency requirements are indicated based upon the piloting task, the role in which the visionics device is used in this task, and the characteristics of the visionics cockpit display device including its resolution, field-of-regard, and field-of-view. The least stringent latency requirements will involve Head-Up Display (HUD) applications, where the visionics imagery provides situational information as a supplement to symbology guidance and command information. Conversely, the visionics system latency requirement for a large field-of-view Head-Worn Display application, providing a Virtual-VMC capability from which the pilot will derive visual guidance, will be the most stringent, having a value as low as 20 msec.

  20. APME launches common method

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    A common approach for carrying out ecological balances for commodity thermoplastics is due to be launched by the Association of Plastics Manufacturers in Europe (APME; Brussels) and its affiliate, The European Centre for Plastics in the Environment (PWMI) this week. The methodology report is the latest stage of a program started in 1990 that aims to describe all operations up to the production of polymer powder or granules at the plant gate. Information gathered will be made freely available to companies considering the use of polymers. An industry task force, headed by PWMI executive director Vince Matthews, has gathered information on the plastics production processes from oil to granule, and an independent panel of specialists, chaired by Ian Boustead of the U.K.'s Open University, devised the methodology and analysis. The methodology report stresses the need to define the system being analyzed and discusses how complex chemical processes can be analyzed in terms of consumption of fuels, energy, and raw materials, as well as solid, liquid, and gaseous emissions

  1. Comparative study of in-situ filter test methods

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1981-01-01

    Available methods of testing high efficiency particulate aerosol (HEPA) filters in-situ have been reviewed. In order to understand the relationship between the results produced by different methods a selection has been compared. Various pieces of equipment for generating and detecting aerosols have been tested and their suitability assessed. Condensation-nuclei, DOP (di-octyl phthalate) and sodium-flame in-situ filter test methods have been studied, using the 500 cfm (9000 m 3 /h) filter test rig at Harwell and in the field. Both the sodium-flame and DOP methods measure the penetration through leaks and filter material. However the measured penetration through filtered leaks depends on the aerosol size distribution and the detection method. Condensation-nuclei test methods can only be used to measure unfiltered leaks since condensation nuclei have a very low penetration through filtered leaks. A combination of methods would enable filtered and unfiltered leaks to be measured. A condensation-nucleus counter using n-butyl alcohol as the working fluid has the advantage of being able to detect any particle up to 1 μm in diameter, including DOP, and so could be used for this purpose. A single-particle counter has not been satisfactory because of interference from particles leaking into systems under extract, particularly downstream of filters, and because the concentration of the input aerosol has to be severely limited. The sodium-flame method requires a skilled operator and may cause safety and corrosion problems. The DOP method using a total light scattering detector has so far been the most satisfactory. It is fairly easy to use, measures reasonably low values of penetration and gives rapid results. DOP has had no adverse effect on HEPA filters over a long series of tests

  2. Fluorescent penetration crack testing method

    International Nuclear Information System (INIS)

    Roth, A.

    1979-01-01

    The same cleaning, penetration, washing, development and evaluation agents are used in this method as for known methods. In order to accelerate or shorten the testing, the drying process is performed only to optical dryness of the material surface by blowing on it with pressurized air, the development by simple pressing into or dusting of the material with the developer and the temperature of the washing water is selected within room temperature range. (RW) [de

  3. In Silico Toxicology – Non-Testing Methods

    Science.gov (United States)

    Raunio, Hannu

    2011-01-01

    In silico toxicology in its broadest sense means “anything that we can do with a computer in toxicology.” Many different types of in silico methods have been developed to characterize and predict toxic outcomes in humans and environment. The term non-testing methods denote grouping approaches, structure–activity relationship, and expert systems. These methods are already used for regulatory purposes and it is anticipated that their role will be much more prominent in the near future. This Perspective will delineate the basic principles of non-testing methods and evaluate their role in current and future risk assessment of chemical compounds. PMID:21772821

  4. Stratum corneum profiles of inflammatory mediators in patch test reactions to common contact allergens and sodium lauryl sulfate

    NARCIS (Netherlands)

    Koppes, S. A.; Ljubojevic Hadzavdic, S.; Jakasa, I.; Franceschi, N.; Jurakić Tončić, R.; Marinović, B.; Brans, R.; Gibbs, S.; Frings-Dresen, M. H. W.; Rustemeyer, T.; Kezic, S.

    2017-01-01

    Background Recent studies have demonstrated allergen-specific differences in the gene expression of inflammatory mediators in patch tested skin. Objectives To determine levels of various inflammatory mediators in the stratum corneum (SC) after patch testing with common contact allergens and the skin

  5. A Comparison of Four Linear Equating Methods for the Common-Item Nonequivalent Groups Design Using Simulation Methods. ACT Research Report Series, 2013 (2)

    Science.gov (United States)

    Topczewski, Anna; Cui, Zhongmin; Woodruff, David; Chen, Hanwei; Fang, Yu

    2013-01-01

    This paper investigates four methods of linear equating under the common item nonequivalent groups design. Three of the methods are well known: Tucker, Angoff-Levine, and Congeneric-Levine. A fourth method is presented as a variant of the Congeneric-Levine method. Using simulation data generated from the three-parameter logistic IRT model we…

  6. Performing Pumping Test Data Analysis Applying Cooper-Jacob’s Method for Estimating of the Aquifer Parameters

    Directory of Open Access Journals (Sweden)

    Dana Khider Mawlood

    2016-06-01

    Full Text Available Single well test is more common than aquifer test with having observation well, since the advantage of single well test is that the pumping test can be conducted on the production well with the absence of observation well. A kind of single well test, which is step-drawdown test used to determine the efficiency and specific capacity of the well, however in case of single well test it is possible to estimate Transmissivity, but the other parameter which is Storativity is overestimated, so the aim of this study is to analyze four pumping test data located in KAWRGOSK area by using cooper-Jacob’s (1946 time drawdown approximation of Theis method to estimate the aquifer parameters, also in order to determine the reasons which are affecting the reliability of the Storativity value and obtain the important aspect behind that in practice.

  7. Validity and power of association testing in family-based sampling designs: evidence for and against the common wisdom.

    Science.gov (United States)

    Knight, Stacey; Camp, Nicola J

    2011-04-01

    Current common wisdom posits that association analyses using family-based designs have inflated type 1 error rates (if relationships are ignored) and independent controls are more powerful than familial controls. We explore these suppositions. We show theoretically that family-based designs can have deflated type-error rates. Through simulation, we examine the validity and power of family designs for several scenarios: cases from randomly or selectively ascertained pedigrees; and familial or independent controls. Family structures considered are as follows: sibships, nuclear families, moderate-sized and extended pedigrees. Three methods were considered with the χ(2) test for trend: variance correction (VC), weighted (weights assigned to account for genetic similarity), and naïve (ignoring relatedness) as well as the Modified Quasi-likelihood Score (MQLS) test. Selectively ascertained pedigrees had similar levels of disease enrichment; random ascertainment had no such restriction. Data for 1,000 cases and 1,000 controls were created under the null and alternate models. The VC and MQLS methods were always valid. The naïve method was anti-conservative if independent controls were used and valid or conservative in designs with familial controls. The weighted association method was generally valid for independent controls, and was conservative for familial controls. With regard to power, independent controls were more powerful for small-to-moderate selectively ascertained pedigrees, but familial and independent controls were equivalent in the extended pedigrees and familial controls were consistently more powerful for all randomly ascertained pedigrees. These results suggest a more complex situation than previously assumed, which has important implications for study design and analysis. © 2011 Wiley-Liss, Inc.

  8. Reduction Methods for Real-time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian

    2016-01-01

    Hybrid testing constitutes a cost-effective experimental full scale testing method. The method was introduced in the 1960's by Japanese researchers, as an alternative to conventional full scale testing and small scale material testing, such as shake table tests. The principle of the method...... is performed on a glass fibre reinforced polymer composite box girder. The test serves as a pilot test for prospective real-time tests on a wind turbine blade. The Taylor basis is implemented in the test, used to perform the numerical simulations. Despite of a number of introduced errors in the real...... is to divide a structure into a physical substructure and a numerical substructure, and couple these in a test. If the test is conducted in real-time it is referred to as real time hybrid testing. The hybrid testing concept has developed significantly since its introduction in the 1960', both with respect...

  9. Evaluation of shrinkage and cracking in concrete of ring test by acoustic emission method

    Science.gov (United States)

    Watanabe, Takeshi; Hashimoto, Chikanori

    2015-03-01

    Drying shrinkage of concrete is one of the typical problems related to reduce durability and defilation of concrete structures. Lime stone, expansive additive and low-heat Portland cement are used to reduce drying shrinkage in Japan. Drying shrinkage is commonly evaluated by methods of measurement for length change of mortar and concrete. In these methods, there is detected strain due to drying shrinkage of free body, although visible cracking does not occur. In this study, the ring test was employed to detect strain and age cracking of concrete. The acoustic emission (AE) method was adopted to detect micro cracking due to shrinkage. It was recognized that in concrete using lime stone, expansive additive and low-heat Portland cement are effective to decrease drying shrinkage and visible cracking. Micro cracking due to shrinkage of this concrete was detected and evaluated by the AE method.

  10. Test Method for Spalling of Fire Exposed Concrete

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt

    2005-01-01

    A new material test method is presented for determining whether or not an actual concrete may suffer from explosive spalling at a specified moisture level. The method takes into account the effect of stresses from hindered thermal expansion at the fire-exposed surface. Cylinders are used, which...... in many countries serve as standard specimens for testing the compressive strength. Consequently, the method is quick, cheap and easy to use in comparison to the alternative of testing full-scale or semi full-scale structures with correct humidity, load and boundary conditions. A number of concretes have...

  11. [Do different interpretative methods used for evaluation of checkerboard synergy test affect the results?].

    Science.gov (United States)

    Ozseven, Ayşe Gül; Sesli Çetin, Emel; Ozseven, Levent

    2012-07-01

    In recent years, owing to the presence of multi-drug resistant nosocomial bacteria, combination therapies are more frequently applied. Thus there is more need to investigate the in vitro activity of drug combinations against multi-drug resistant bacteria. Checkerboard synergy testing is among the most widely used standard technique to determine the activity of antibiotic combinations. It is based on microdilution susceptibility testing of antibiotic combinations. Although this test has a standardised procedure, there are many different methods for interpreting the results. In many previous studies carried out with multi-drug resistant bacteria, different rates of synergy have been reported with various antibiotic combinations using checkerboard technique. These differences might be attributed to the different features of the strains. However, different synergy rates detected by checkerboard method have also been reported in other studies using the same drug combinations and same types of bacteria. It was thought that these differences in synergy rates might be due to the different methods of interpretation of synergy test results. In recent years, multi-drug resistant Acinetobacter baumannii has been the most commonly encountered nosocomial pathogen especially in intensive-care units. For this reason, multidrug resistant A.baumannii has been the subject of a considerable amount of research about antimicrobial combinations. In the present study, the in vitro activities of frequently preferred combinations in A.baumannii infections like imipenem plus ampicillin/sulbactam, and meropenem plus ampicillin/sulbactam were tested by checkerboard synergy method against 34 multi-drug resistant A.baumannii isolates. Minimum inhibitory concentration (MIC) values for imipenem, meropenem and ampicillin/sulbactam were determined by the broth microdilution method. Subsequently the activity of two different combinations were tested in the dilution range of 4 x MIC and 0.03 x MIC in

  12. Toward generally accepted forensic assessment practices among clinical neuropsychologists: a survey of professional practice and common test use.

    Science.gov (United States)

    LaDuke, Casey; Barr, William; Brodale, Donald L; Rabin, Laura A

    2018-01-01

    This study investigated professional practice and common test use among clinical neuropsychologists engaging in forensic assessment.  Doctorate-level psychologists active in the practice of neuropsychology and on the INS and NAN membership listings (n = 502) were surveyed about their demographics, professional practice, and common test use. Participants who reported engaging in forensic practice (n = 255) were further surveyed about their forensic practice. Forensic participants were more likely to be male and Caucasian, and reported higher ages, more years of professional experience, and a higher prevalence of board certification. While characteristics of their professional and forensic practice varied, forensic participants reported spending most of their professional time conducting neuropsychological assessments with adult clients in a private or group practice setting, focusing on civil referrals and civil legal questions involving older adult issues, developmental issues, head injury, and psychiatric issues. Common test use across neuropsychological assessment domains is presented for board-certified forensic participants (n = 77). An examination of these results reveals that the current pattern of test use is similar to the results of a more general survey of neuropsychological test use.  The findings provide insight into the practice of forensic neuropsychological assessment, and further establish the admissibility of neuropsychological evidence in the United States legal system. Results will be useful for clinical neuropsychologists, field leaders, and legal professionals hoping to gain insight into the role of clinical neuropsychology in civil and criminal legal decision-making.

  13. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  14. Development of a test method for sowing machines concerning the drift of dust abrasion

    Directory of Open Access Journals (Sweden)

    Bahmer, Roland

    2014-02-01

    Full Text Available For a long time the seed treatment was regarded as the most effective and in terms of the impact of the natural environment as the safest form of plant protection. Since the serious damage of bees, caused by dust of abraded seed treatment in the Rhine Valley five years ago, the admission of seed treatment products containing insecticide is in the discussion. To evaluate the emission characteristics of sowing machines during sowing based on secure data, the technical basis for a test method for measuring the drift of abraded seed-dust in sowing machines were developed at the Centre for Agricultural Technology Augustenberg. An indoor test bench was created and a standardized test method by which it is possible to evaluate the drift behavior of sowing machines in comparison was developed. A granulate which is stained with a fluorescent Tracer is used as test seed. The „tracer technique“ allows a reproducible, rapid and inexpensive assessment of the drift behavior of the sowing technology, which is commonly used. To classify the obtained drift values in the test bench, measurements in the field were carried out for comparison. The determined drift volumes of those measurements were at a similar level as the measured values in the test stand. Therefore the standardized measurement of drift in the test stand is suitable for the calculation of exposure scenarios for the sowing of treated seeds.

  15. Comparison of test methods for mould growth in buildings

    DEFF Research Database (Denmark)

    Bonderup, Sirid; Gunnarsen, Lars Bo; Knudsen, Sofie Marie

    2016-01-01

    renovation needs. This is of importance when hidden surface testing would require destructive measures and subsequent renovation. After identifying available methods on the Danish market for assessing mould growth in dwellings, a case study was conducted to test the usefulness of the methods in four......The purpose of this work is to compare a range of test methods and kits for assessing whether a building structure is infested by mould fungi. A further purpose of this work is to evaluate whether air-based methods for sampling fungal emissions provide information qualifying decisions concerning...... methods measure different aspects relating to mould growth and vary in selectivity and precision. The two types of air samples indicated low levels of mould growth, even where the results of the other methods indicated high to moderate growth. With methods based on culture and DNA testing some differences...

  16. 40 CFR Appendix A to Part 63 - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods A Appendix A to Part 63... to Part 63—Test Methods Method 301—Field Validation of Pollutant Measurement Methods from Various Waste Media 1. Applicability and principle 1.1Applicability. This method, as specified in the applicable...

  17. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  18. THE METHOD OF GEOMETRIC CALIBRATION OF OPTOELECTRONIC SYSTEMS BASED ON ELECTRONIC TEST OBJECT

    Directory of Open Access Journals (Sweden)

    D. A. Kozhevnikov

    2017-01-01

    Full Text Available Designing remote sensing of the Earth devices is requires a lot of attention to evaluation lens distortion level and providing the required accuracy values of geometric calibration of optoelectronic systems at all. Test- objects known as most common tools for optical systems geometric calibration. The purpose of the research was creating an automatically method of distortion correction coefficients calculating with a 3 μm precision in the measurement process. The method of geometric calibration of the internal orientation elements of the optical system based on the electronic test object is proposed. The calculation of the test string brightness image from its multispectral image and filtered signal extrema position determination are presented. Ratio of magnitude of the distortion and interval center is given. Three variants of electronic test-objects with different step and element size are considered. Оptimal size of calibration element was defined as 3×3 pixels due to shape of the subpixels with the aspect ratio of the radiating areas about 1 : 3. It is advisable to use IPS as an electronic test object template. An experimental test and measurement stand functional diagram based on the collimator and optical bench «OSK-2CL» is showed. It was determined that test objects with a grid spacing of 4 and 8 pixels can’t provide tolerable image because of non-collimated emission of active sites and scattering on optical surfaces – the shape of the elements is substantially disrupted. Test-object with a 12 pixels grid spacing was used to distortion level analyzing as most suitable.Ratio of coordinate increment and element number graphs for two photographic lenses (Canon EF-S 17-85 f/4-5.6 IS USM and EF-S 18-55 f/3.5-5.6 IS II are presented. A calculation of the distortion values in edge zones was held, which were respectively 43 μm and 51.6 μm. The technique and algorithm of software implementation is described. Possible directions of the

  19. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    Shin, Sung Min; Kim, Hee Eun; Kang, Hyun Gook; Lee, Sung Jiun

    2014-01-01

    The V and V method has been utilized for this safety critical software, while SRGM has difficulties because of lack of failure occurrence data on developing phase. For the safety critical software, however, failure data cannot be gathered after installation in real plant when we consider the severe consequence. Therefore, to complement the V and V method, the test-based method need to be developed. Some studies on test-based reliability quantification method for safety critical software have been conducted in nuclear field. These studies provide useful guidance on generating test sets. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values. The other problem is number of tests needed. To satisfy a target reliability with reasonable confidence level, very large number of test sets are required. Development of this number of test sets is a herculean

  20. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... different vehicles. A unified method for testing the efficiency of the charger in EVs, without direct access to the component, is presented. The method is validated through extensive tests of the models Renault Zoe, Nissan LEAF and Peugeot iOn. The results show a loss between 15 % and 40 %, which is far...

  1. Factors that affect the physical science career interest of female students: Testing five common hypotheses

    Science.gov (United States)

    Hazari, Zahra; Potvin, Geoff; Lock, Robynne M.; Lung, Florin; Sonnert, Gerhard; Sadler, Philip M.

    2013-12-01

    There are many hypotheses regarding factors that may encourage female students to pursue careers in the physical sciences. Using multivariate matching methods on national data drawn from the Persistence Research in Science and Engineering (PRiSE) project (n=7505), we test the following five commonly held beliefs regarding what factors might impact females’ physical science career interest: (i) having a single-sex physics class, (ii) having a female physics teacher, (iii) having female scientist guest speakers in physics class, (iv) discussing the work of female scientists in physics class, and (v) discussing the underrepresentation of women in physics class. The effect of these experiences on physical science career interest is compared for female students who are matched on several factors, including prior science interests, prior mathematics interests, grades in science, grades in mathematics, and years of enrollment in high school physics. No significant effects are found for single-sex classes, female teachers, female scientist guest speakers, and discussing the work of female scientists. However, discussions about women’s underrepresentation have a significant positive effect.

  2. Comparison of performance of some common Hartmann-Shack centroid estimation methods

    Science.gov (United States)

    Thatiparthi, C.; Ommani, A.; Burman, R.; Thapa, D.; Hutchings, N.; Lakshminarayanan, V.

    2016-03-01

    The accuracy of the estimation of optical aberrations by measuring the distorted wave front using a Hartmann-Shack wave front sensor (HSWS) is mainly dependent upon the measurement accuracy of the centroid of the focal spot. The most commonly used methods for centroid estimation such as the brightest spot centroid; first moment centroid; weighted center of gravity and intensity weighted center of gravity, are generally applied on the entire individual sub-apertures of the lens let array. However, these processes of centroid estimation are sensitive to the influence of reflections, scattered light, and noise; especially in the case where the signal spot area is smaller compared to the whole sub-aperture area. In this paper, we give a comparison of performance of the commonly used centroiding methods on estimation of optical aberrations, with and without the use of some pre-processing steps (thresholding, Gaussian smoothing and adaptive windowing). As an example we use the aberrations of the human eye model. This is done using the raw data collected from a custom made ophthalmic aberrometer and a model eye to emulate myopic and hyper-metropic defocus values up to 2 Diopters. We show that the use of any simple centroiding algorithm is sufficient in the case of ophthalmic applications for estimating aberrations within the typical clinically acceptable limits of a quarter Diopter margins, when certain pre-processing steps to reduce the impact of external factors are used.

  3. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  4. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  5. 26 CFR 1.401(a)(26)-7 - Testing methods.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Testing methods. 1.401(a)(26)-7 Section 1.401(a... (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.401(a)(26)-7 Testing methods... the rules in § 1.401(a)(26)-5. (b) Simplified testing method. A plan is treated as satisfying the...

  6. Helium leak testing methods in nuclear applications

    International Nuclear Information System (INIS)

    Ahmad, Anis

    2004-01-01

    Helium mass-spectrometer leak test is the most sensitive leak test method. It gives very reliable and sensitive test results. In last few years application of helium leak testing has gained more importance due to increased public awareness of safety and environment pollution caused by number of growing chemical and other such industries. Helium leak testing is carried out and specified in most of the critical area applications like nuclear, space, chemical and petrochemical industries

  7. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  8. Alternative method of inservice hydraulic testing of difficult to test pumps

    International Nuclear Information System (INIS)

    Stockton, N.B.; Shangari, S.

    1994-01-01

    The pump test codes require that system resistance be varied until the independent variable (either the pump flow rate or differential pressure) equals its reference value. Variance from this fixed reference value is not specifically allowed. However, the design of many systems makes it impractical to set the independent variable to an exact value. Over a limited range of pump operation about the fixed reference value, linear interpolation between two points of pump operation can be used to accurately determine degradation at the reference value without repeating reference test conditions. This paper presents an overview of possible alternatives for hydraulic testing of pumps and a detailed discussion of the linear interpolation method. The approximation error associated with linear interpolation is analyzed. Methods to quantify and minimize approximation error are presented

  9. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  10. 40 CFR 60.1300 - What test methods must I use to stack test?

    Science.gov (United States)

    2010-07-01

    ... to the Administrator for approval under § 60.8(b) to use a reference method with minor changes in... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...

  11. 40 CFR 76.15 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...

  12. Practicable group testing method to evaluate weight/weight GMO content in maize grains.

    Science.gov (United States)

    Mano, Junichi; Yanaka, Yuka; Ikezu, Yoko; Onishi, Mari; Futo, Satoshi; Minegishi, Yasutaka; Ninomiya, Kenji; Yotsuyanagi, Yuichi; Spiegelhalter, Frank; Akiyama, Hiroshi; Teshima, Reiko; Hino, Akihiro; Naito, Shigehiro; Koiwa, Tomohiro; Takabatake, Reona; Furui, Satoshi; Kitta, Kazumi

    2011-07-13

    Because of the increasing use of maize hybrids with genetically modified (GM) stacked events, the established and commonly used bulk sample methods for PCR quantification of GM maize in non-GM maize are prone to overestimate the GM organism (GMO) content, compared to the actual weight/weight percentage of GM maize in the grain sample. As an alternative method, we designed and assessed a group testing strategy in which the GMO content is statistically evaluated based on qualitative analyses of multiple small pools, consisting of 20 maize kernels each. This approach enables the GMO content evaluation on a weight/weight basis, irrespective of the presence of stacked-event kernels. To enhance the method's user-friendliness in routine application, we devised an easy-to-use PCR-based qualitative analytical method comprising a sample preparation step in which 20 maize kernels are ground in a lysis buffer and a subsequent PCR assay in which the lysate is directly used as a DNA template. This method was validated in a multilaboratory collaborative trial.

  13. Nondestructive testing methods for 55-gallon, waste storage drums

    International Nuclear Information System (INIS)

    Ferris, R.H.; Hildebrand, B.P.; Hockey, R.L.; Riechers, D.M.; Spanner, J.C.; Duncan, D.R.

    1993-06-01

    The Westinghouse Hanford Company (WHC) authorized Pacific Northwest Laboratory (PNL) to conduct a feasibility study to identify promising nondestructive testing (NDT) methods for detecting general and localized (both pitting and pinhole) corrosion in the 55-gal drums that are used to store solid waste materials at the Hanford Site. This document presents results obtained during a literature survey, identifies the relevant reference materials that were reviewed, provides a technical description of the methods that were evaluated, describes the laboratory tests that were conducted and their results, identifies the most promising candidate methods along with the rationale for these selections, and includes a work plan for recommended follow-on activities. This report contains a brief overview and technical description for each of the following NDT methods: magnetic testing techniques; eddy current testing; shearography; ultrasonic testing; radiographic computed tomography; thermography; and leak testing with acoustic detection

  14. Stopping test of iterative methods for solving PDE

    International Nuclear Information System (INIS)

    Wang Bangrong

    1991-01-01

    In order to assure the accuracy of the numerical solution of the iterative method for solving PDE (partial differential equation), the stopping test is very important. If the coefficient matrix of the system of linear algebraic equations is strictly diagonal dominant or irreducible weakly diagonal dominant, the stopping test formulas of the iterative method for solving PDE is proposed. Several numerical examples are given to illustrate the applications of the stopping test formulas

  15. Methods of Usability Testing in Libraries Web Sites

    Directory of Open Access Journals (Sweden)

    Eman Fawzy

    2006-03-01

    Full Text Available A Study about libraries' web sites evaluation, that is the Usability, the study talking about methods of usability testing and define it, and its important in web sites evaluation, then details the methods of usability: questionnaire, core groups, testing experimental model, cards arrangement, and composed evaluation.

  16. Voter Perceptions: Common Core State Standards & Tests

    Science.gov (United States)

    Achieve, Inc., 2014

    2014-01-01

    Since June 2010, 46 states and Washington DC have adopted the Common Core State Standards (CCSS)--K-12 standards in mathematics and English language arts/literacy developed through a multi-state initiative led by the National Governors Association and the Council of Chief State School Officers. Implementation of the standards is underway in all of…

  17. A review of the effects on IRT item parameter estimates with a focus on misbehaving common items in test equating

    Directory of Open Access Journals (Sweden)

    Michalis P Michaelides

    2010-10-01

    Full Text Available Many studies have investigated the topic of change or drift in item parameter estimates in the context of Item Response Theory. Content effects, such as instructional variation and curricular emphasis, as well as context effects, such as the wording, position, or exposure of an item have been found to impact item parameter estimates. The issue becomes more critical when items with estimates exhibiting differential behavior across test administrations are used as common for deriving equating transformations. This paper reviews the types of effects on IRT item parameter estimates and focuses on the impact of misbehaving or aberrant common items on equating transformations. Implications relating to test validity and the judgmental nature of the decision to keep or discard aberrant common items are discussed, with recommendations for future research into more informed and formal ways of dealing with misbehaving common items.

  18. A Review of the Effects on IRT Item Parameter Estimates with a Focus on Misbehaving Common Items in Test Equating.

    Science.gov (United States)

    Michaelides, Michalis P

    2010-01-01

    Many studies have investigated the topic of change or drift in item parameter estimates in the context of item response theory (IRT). Content effects, such as instructional variation and curricular emphasis, as well as context effects, such as the wording, position, or exposure of an item have been found to impact item parameter estimates. The issue becomes more critical when items with estimates exhibiting differential behavior across test administrations are used as common for deriving equating transformations. This paper reviews the types of effects on IRT item parameter estimates and focuses on the impact of misbehaving or aberrant common items on equating transformations. Implications relating to test validity and the judgmental nature of the decision to keep or discard aberrant common items are discussed, with recommendations for future research into more informed and formal ways of dealing with misbehaving common items.

  19. ξ common cause failure model and method for defense effectiveness estimation

    International Nuclear Information System (INIS)

    Li Zhaohuan

    1991-08-01

    Two issues have been dealt. One is to develop an event based parametric model called ξ-CCF model. Its parameters are expressed in the fraction of the progressive multiplicities of failure events. By these expressions, the contribution of each multiple failure can be presented more clearly. It can help to select defense tactics against common cause failures. The other is to provide a method which is based on the operational experience and engineering judgement to estimate the effectiveness of defense tactics. It is expressed in terms of reduction matrix for a given tactics on a specific plant in the event by event form. The application of practical example shows that the model in cooperation with the method can simply estimate the effectiveness of defense tactics. It can be easily used by the operators and its application may be extended

  20. Methods for testing of geometrical down-scaled rotor blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    further developed since then. Structures in composite materials are generally difficult and time consuming to test for fatigue resistance. Therefore, several methods for testing of blades have been developed and exist today. Those methods are presented in [1]. Current experimental test performed on full...

  1. Two Classification Methods for Grouping Common Environmental Sounds in Terms of Perceived Pleasantness

    Science.gov (United States)

    2016-02-01

    NUMBER OF PAGES 24 19a. NAME OF RESPONSIBLE PERSON Kelly Dickerson a. REPORT Unclassified b. ABSTRACT Unclassified c . THIS...ARL-TR-7960 ● FEB 2016 US Army Research Laboratory Two Classification Methods for Grouping Common Environmental Sounds in Terms...of Perceived Pleasantness by Kelly Dickerson, Brandon S Perelman, Laura Sherry, and Jeremy R Gaston Approved for public

  2. Corrosion evaluation in insulated pipes by non destructive testing method

    International Nuclear Information System (INIS)

    Abd Razak Hamzah; Azali Muhammad; Mohammad Pauzi Ismail; Abd Nassir Ibrahim; Abd Aziz Mohamed; Sufian Saad; Saharuddin Sayuti; Shukri Ahmad

    2002-01-01

    In engineering plants, detection of corrosion and evaluation of deposit in insulated pipes using radiography method are considered as a very challenging tasks. In General this degradation problem is attributed to water condensation. It causes the formation of deposit and scale inside the pipe, as well as between the insulation and pipe in cold temperature pipes. On the other hand, for hot temperature pipes the main problem is mainly due to corrosion/erosion attack inside the pipe. In the study of corrosion in pipelines, one of the most important parameters to be monitored and measured is the wall thickness. Currently, most pipeline corrosion monitoring and evaluation for both insulated and non-insulated pipes is performed using an ultrasonic method. The most common technique is that based on the A-Scan, using either a normal flaw detector or some form of dedicated equipment. However, with recent development of ultrasonic technology, more advance method, namely B-Scan and C-scan techniques are also available. The most notable disadvantage of using this method is that the insulation covering the pipe has to be removed before the inspection can be carried out and this is considered as not so cost effective. Due to this reason, the possibility of employing other alternative NDT method, namely radiographic testing method were studied. The technique used in this studied are known as tangential technique. In this study it was found that the result found using tangential technique is consistent with the actual thickness of the pipe. Result of this study is presented and discussed in this paper. (Author)

  3. Alternative method for intramuscular fat analysis using common laboratory equipment.

    Science.gov (United States)

    Segura, J; Calvo, L; Óvilo, C; González-Bulnes, A; Olivares, A; Cambero, M I; López-Bote, C J

    2015-05-01

    A procedure to quantify intramuscular fat was developed using common inexpensive laboratory equipment. Three homogenization methods of lyophilized muscle samples (Ball-mill, Grinder and Mortar) and two extraction methods (Ball-mill or Vortex) were used in turkey meat and pork. Two-hundred mg of lyophilized and homogenized samples were accurately weighed and mixed with 1.5 mL of dichloromethane-methanol (8:2) and shaken either in a Mixer Mill (MM400, Retsch Technology) or in a Vortex. The final mixture was separated by centrifugation. Solvent was evaporated under a nitrogen stream and lipid content was gravimetrically determined. Besides, it was checked that the fatty acid profile was not altered by the protocol used. Moreover, the analysis of 4 replicas from the same sample showed different variation coefficients (16-29%) for the new procedures proposed over a wide range of IMF content. The combination of Grinder and Vortex methodologies can be proposed as a simple and inexpensive alternative to previous ones. Copyright © 2015. Published by Elsevier Ltd.

  4. Testing method for ceramic armour and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2016-01-01

    TNO developed an alternative, more configuration independent ceramic test method than the Depth-of-Penetration test method. In this alternative test ceramic tiles and ceramic based armour are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  5. Testing method for ceramic armor and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2014-01-01

    TNO has developed an alternative, more configuration independent ceramic test method than the standard Depth-of-Penetration test method. In this test ceramic tiles and ceramic based armor are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  6. Comparison of sine dwell and broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  7. Yield and cost of individual common diagnostic tests in new primary care outpatients in Japan.

    Science.gov (United States)

    Takemura, Yuzuru; Ishida, Haku; Inoue, Yuji; Beck, J Robert

    2002-01-01

    Appropriate diagnostic testing involves considerations of cost-effectiveness. We examined the cost-effectiveness of individual tests in a panel of tests defined by the Japan Society of Clinical Pathology. We studied 540 new, symptomatic primary care outpatients with a set of 30 common diagnostic tests [the Essential Laboratory Tests (2); ELT(2) panel] for clinical evaluation and identification of occult disease. A useful result (UR) of testing was defined as a finding that contributed to a change in a physician's diagnosis or decision-making relating to a "tentative initial diagnosis" obtained from history and physical examination alone. The ELT(2) panel testing yielded 398 URs and uncovered 261 occult diseases among 540 patients. In total, 1592 tests contributed to either UR-generation or discovery of occult disease. The cost per effective test (cost required per test that contributed to either definition of effectiveness) ranged from 108 yen (approximately 0.92 US dollars) for total cholesterol to 6200 yen (approximately 52.50 dollars) for chest x-ray. Contribution rates and the cost per effective test varied among disease categories. We restructured panel components considering the effectiveness of each test. Subsets of the ELT(2) would have improved cost-effectiveness and achieved cost savings in five of eight disease categories. Assembly of tests based on cost-effectiveness can improve clinical efficiency and decrease total cost of panel testing for selected patient groups.

  8. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test method for uranium by Iron (II) reduction in phosphoric acid followed by chromium (VI) titration in the presence of vanadium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method, commonly referred to as the Modified Davies and Gray technique, covers the titration of uranium in product, fuel, and scrap materials after the material is dissolved. The test method is versatile and has been ruggedness tested. With appropriate sample preparation, this test method can give precise and unbiased uranium assays over a wide variety of material types (1, 2). Details of the titration procedure in the presence of plutonium with appropriate modifications are given in Test Method C1204. 1.2 Uranium levels titrated are usually 20 to 50 mg, but up to 200 mg uranium can be titrated using the reagent volumes stated in this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determ...

  10. Performance Validity Testing in Neuropsychology: Methods for Measurement Development and Maximizing Diagnostic Accuracy.

    Science.gov (United States)

    Wodushek, Thomas R; Greher, Michael R

    2017-05-01

    In the first column in this 2-part series, Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review, the authors introduced performance validity tests (PVTs) and their function, provided a justification for why they are necessary, traced their ongoing endorsement by neuropsychological organizations, and described how they are used and interpreted by ever increasing numbers of clinical neuropsychologists. To enhance readers' understanding of these measures, this second column briefly describes common detection strategies used in PVTs as well as the typical methods used to validate new PVTs and determine cut scores for valid/invalid determinations. We provide a discussion of the latest research demonstrating how neuropsychologists can combine multiple PVTs in a single battery to improve sensitivity/specificity to invalid responding. Finally, we discuss future directions for the research and application of PVTs.

  11. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Antifungal susceptibility testing of vaginal candida isolates: the broth microdilution method

    Directory of Open Access Journals (Sweden)

    Mahmoudi Rad M

    2010-02-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Vulvovaginal candidiasis is a common mucosal infection among immunocompetent, healthy women, and is caused by opportunistic yeasts that belong to genus Candida. In this study, we isolated and identified the Candida species in the vagina of patients who admitted in Gynecology Department of Mahdieh Hospital in Tehran, Iran to evaluate the in vitro activities of fluconazole, miconazole, itraconazole and flucytosine against 191 clinical Candida isolates by the NCCLS microdilution method."n"nMethods: 191 Candida were isolated from vaginal secretions and identified with conventional mycological methods in the diagnosis of Candida species. The identity of all strains was confirmed genotypically by multiplex PCR. In vitro susceptibility testing of vaginal Candida isolates was performed by the NCCLS broth microdilution method. The results were read at 48 h."n"nResults: Most C. albicans isolates (>90% were sensitive in vitro to the antifungal agents tested. Most C. glabrata isolates showed sensitivity to miconazole and then flucytosine while they were more resistant to Itraconazole and fluconazole. Many isolates of C. tropicalis were susceptible to miconazole and then fluconazole. They showed a little resistance to

  13. Leakage localisation method in a water distribution system based on sensitivity matrix: methodology and real test

    OpenAIRE

    Pascual Pañach, Josep

    2010-01-01

    Leaks are present in all water distribution systems. In this paper a method for leakage detection and localisation is presented. It uses pressure measurements and simulation models. Leakage localisation methodology is based on pressure sensitivity matrix. Sensitivity is normalised and binarised using a common threshold for all nodes, so a signatures matrix is obtained. A pressure sensor optimal distribution methodology is developed too, but it is not used in the real test. To validate this...

  14. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  15. Well test imaging - a new method for determination of boundaries from well test data

    Energy Technology Data Exchange (ETDEWEB)

    Slevinsky, B.A.

    1997-08-01

    A new method has been developed for analysis of well test data, which allows the direct calculation of the location of arbitrary reservoir boundaries which are detected during a well test. The method is based on elements of ray tracing and information theory, and is centered on the calculation of an instantaneous {open_quote}angle of view{close_quote} of the reservoir boundaries. In the absence of other information, the relative reservoir shape and boundary distances are retrievable in the form of a Diagnostic Image. If other reservoir information, such as 3-D seismic, is available; the full shape and orientation of arbitrary (non-straight line or circular arc) boundaries can be determined in the form of a Reservoir Image. The well test imaging method can be used to greatly enhance the information available from well tests and other geological data, and provides a method to integrate data from multiple disciplines to improve reservoir characterization. This paper covers the derivation of the analytical technique of well test imaging and shows examples of application of the technique to a number of reservoirs.

  16. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  17. An evaluation of the whole effluent toxicity test method

    International Nuclear Information System (INIS)

    Osteen, D.V.

    1999-01-01

    Whole effluent toxicity (WET) testing has become increasingly more important to the Environmental Protection Agency (EPA) and the States in the permitting of wastewater discharges from industry and municipalities. The primary purpose of the WET test is to protect aquatic life by predicting the effect of an effluent on the receiving stream. However, there are both scientific and regulatory concerns that using WET tests to regulate industrial effluents may result in either false positives and/or false negatives. In order to realistically predict the effect of an effluent on the receiving stream, the test should be as representative as possible of the conditions in the receiving stream. Studies (Rand and Petrocelli 1985) suggested several criteria for an ideal aquatic toxicity test organism, one of which is that the organism be indigenous to, or representative of, the ecosystem receiving the effluent. The other component needed in the development of a predictive test is the use of the receiving stream water or similar synthetic water as the control and dilution water in the test method. Use of an indigenous species and receiving water in the test should help reduce the variability in the method and allow the test to predict the effect of the effluent on the receiving stream. The experience with toxicity testing at the Savannah River Site (SRS) has yielded inconclusive data because of the inconsistency and unreliability of the results. The SRS contention is that the WET method in its present form does not adequately mimic actual biological/chemical conditions of the receiving streams and is neither reasonable nor accurate. This paper discusses the rationale for such a position by SRS on toxicity testing in terms of historical permitting requirements, outfall effluent test results, standard test method evaluation, scientific review of alternate test species, and concerns over the test method expressed by other organizations. This paper presents the Savannah River Site

  18. Comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1996-07-01

    In this paper the classical sequential probability ratio testing method (SPRT) is reconsidered. Every individual boundary crossing event of the SPRT is regarded as a new piece of evidence about the problem under hypothesis testing. The Bayes method is applied for belief updating, i.e. integrating these individual decisions. The procedure is recommended to use when the user (1) would like to be informed about the tested hypothesis continuously and (2) would like to achieve his final conclusion with high confidence level. (Author).

  19. Seismic test qualification of electrical equipment - testing methods in use to EDF

    International Nuclear Information System (INIS)

    Fabries, R.

    1981-01-01

    At the beginning, for the 900 MW Power Plant level, the testing method in application used the single axis test by sine beat of 10 cycles according to the specifications of the guide IEEE 344-71. When the french guide UTEC 20-420 came into force we have had to define another testing method (EDF standard: HN20 E52) which utilize the single-axis test either by a sine beat of 5-cycles or by a synthetized time history. We present here the mains criterions allowing to justify: -The single-axis test. The single frequency wave (when the Initial Response Spectrum (IRS) present a narrow band). The use of one sine beat of 5-cycles or one synthetized time history. The need of taking into account the high stress level. This oligocyclic stress fatigue explains why one beat of 5-cycles may be as severe as one time history of 20 seconds (with the same level of strong response spectrum). Then, we conclude that the durating of the testing wave applied to the equipment shall be considered as a relative parameter only. The weight of the SSE tests by respect to the OBE tests. The precautions to take in order to: generate and check accurately the synthetized time history, choice the test frequencies when the sine beat is used. (orig./HP)

  20. From the Kirsch-Kress potential method via the range test to the singular sources method

    International Nuclear Information System (INIS)

    Potthast, R; Schulz, J

    2005-01-01

    We review three reconstruction methods for inverse obstacle scattering problems. We will analyse the relation between the Kirsch-Kress potential method 1986, the range test of Kusiak, Potthast and Sylvester (2003) and the singular sources method of Potthast (2000). In particular, we show that the range test is a logical extension of the Kirsch-Kress method into the category of sampling methods employing the tool of domain sampling. Then we will show how a multi-wave version of the range test can be set up and we will work out its relation to the singular sources method. Numerical examples and demonstrations will be provided

  1. Design of clinical trials involving multiple hypothesis tests with a common control.

    Science.gov (United States)

    Schou, I Manjula; Marschner, Ian C

    2017-07-01

    Randomized clinical trials comparing several treatments to a common control are often reported in the medical literature. For example, multiple experimental treatments may be compared with placebo, or in combination therapy trials, a combination therapy may be compared with each of its constituent monotherapies. Such trials are typically designed using a balanced approach in which equal numbers of individuals are randomized to each arm, however, this can result in an inefficient use of resources. We provide a unified framework and new theoretical results for optimal design of such single-control multiple-comparator studies. We consider variance optimal designs based on D-, A-, and E-optimality criteria, using a general model that allows for heteroscedasticity and a range of effect measures that include both continuous and binary outcomes. We demonstrate the sensitivity of these designs to the type of optimality criterion by showing that the optimal allocation ratios are systematically ordered according to the optimality criterion. Given this sensitivity to the optimality criterion, we argue that power optimality is a more suitable approach when designing clinical trials where testing is the objective. Weighted variance optimal designs are also discussed, which, like power optimal designs, allow the treatment difference to play a major role in determining allocation ratios. We illustrate our methods using two real clinical trial examples taken from the medical literature. Some recommendations on the use of optimal designs in single-control multiple-comparator trials are also provided. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  3. Corrosion and deposit evaluation in industrial plants by non destructive testing method

    International Nuclear Information System (INIS)

    Azali Muhammad; Abd Razak Hamzah; Abd Aziz Mohamed; Mohd Pauzi Ismail; S Saad; S Sayuti; S Ahmad

    2000-01-01

    In petrochemical plants, the detection of corrosion and evaluation of deposit in insulated pipes using a radiography method are very challenging tasks. This main degradation problem experienced by pipelines is due to water condensation. It will cause deposit and scale inside the pipe, as well as between the insulation and pipe for the cold temperature pipes. On the other hand, for the hot temperature pipes the main problem is mainly due to corrosion/erosion attack inside the pipe. In the case of corrosion study one of the most important parameters in a piping or pipeline to be monitored and measured is that the wall thickness. In general, most pipeline corrosion monitoring and evaluation for both insulated and non-insulated pipes is done by using an ultrasonic method. The most common technique for corrosion is that based on the A-Scan, using either a normal flow detector or some form of dedicated equipment. However, with recent development of ultrasonic technology, more advance method, namely B-Scan and C-scan techniques are also available. The most notable disadvantage of using this current method is that the insulation covered the pipe has to be removed before the inspection can be carried out and this is considered as not so cost effective. Due to this reason other alternative NDT method, namely radiographic testing method has been studied. The testing technique used in this studied are tangential technique and double wall radiographic technique which involve studying the changing in density of radiographic film. The result found using tangential technique is consistent with real thickness of the pipe. However for the later technique the result is only achieved with a reasonable accuracy when the changing in wall thickness is very small. The result of the studies is discussed in this paper

  4. Free-free and fixed base modal survey tests of the Space Station Common Module Prototype

    Science.gov (United States)

    Driskill, T. C.; Anderson, J. B.; Coleman, A. D.

    1992-01-01

    This paper describes the testing aspects and the problems encountered during the free-free and fixed base modal surveys completed on the original Space Station Common Module Prototype (CMP). The CMP is a 40-ft long by 14.5-ft diameter 'waffle-grid' cylinder built by the Boeing Company and housed at the Marshall Space Flight Center (MSFC) near Huntsville, AL. The CMP modal survey tests were conducted at MSFC by the Dynamics Test Branch. The free-free modal survey tests (June '90 to Sept. '90) included interface verification tests (IFVT), often referred to as impedance measurements, mass-additive testing and linearity studies. The fixed base modal survey tests (Feb. '91 to April '91), including linearity studies, were conducted in a fixture designed to constrain the CMP in 7 total degrees-of-freedom at five trunnion interfaces (two primary, two secondary, and the keel). The fixture also incorporated an airbag off-load system designed to alleviate the non-linear effects of friction in the primary and secondary trunnion interfaces. Numerous test configurations were performed with the objective of providing a modal data base for evaluating the various testing methodologies to verify dynamic finite element models used for input to coupled load analysis.

  5. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  6. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  7. Development of standard testing methods for nuclear-waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.

    1981-11-01

    Standard test methods for waste package component development and design, safety analyses, and licensing are being developed for the Nuclear Waste Materials Handbook. This paper describes mainly the testing methods for obtaining waste form materials data

  8. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  9. A method for evaluating horizontal well pumping tests.

    Science.gov (United States)

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  10. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  11. Potassium Dichromate as a Reference Substance for Embryonic Tests of Toxicity in the Common Carp (Cyprinus carpio L.

    Directory of Open Access Journals (Sweden)

    R. Krejčí

    2006-01-01

    Full Text Available Potassium dichromate (K2Cr2O7 has already been used as a reference substance in tests of toxicity with aquatic animals. The aim of this study was to determine and compare values of LC50 for potassium dichromate during the whole period of embryonic development (i.e., 120 h and 48 h after hatching of embryos in the common carp (Cyprinus carpio L.. Fish eggs and embryos were exposed to 5 different concentrations of potassium dichromate (i.e., 372, 409, 450, 495, 545 mg l-1 during two experiments. Such characteristics as the cumulative mortality, the start and the end of hatching, the number of deformities, body length, and body mass of surviving individuals were studied during the tests. The highest mortality was found in the hatched embryos. Mortality and frequency of deformities increased with the growing concentration of potassium dichromate. The value of 120 LC50 for potassium dichromate was 464.91 ± 23.83 mg l-1 and the value of 48 LC50 was 458.94 ± 4.14 mg l-1 (mean ± SD. No statistically significant difference between values 120 LC50 a 48 LC50 was found. This is why reduction of the exposure period to only 48 h after hatching seems a reasonable method to study the control of susceptibility using potassium dichromate in embryonic tests of toxicity.

  12. Project size and common pool size: An empirical test using Danish municipal mergers

    DEFF Research Database (Denmark)

    Hansen, Sune Welling

    The paper examines the proposition that project size tends to increase with common pool size from the law of 1 over n (Weingast et al, 1981). This remains under-investigated and a recent study conducted by Primo & Snyder (2008) argues, and empirically substantiates, a reverse law of 1 over n...... across two research designs, two outcome variables, two subsamples, and several model specifications The implications of the findings, combined with the limited potential for empirically testing Primo & Snyder’s alternative model, suggest a re-appreciation of the law of 1 over n as it was originally...

  13. Testing and Validation of the Dynamic Inertia Measurement Method

    Science.gov (United States)

    Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David

    2015-01-01

    The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

  14. System diagnosis using finite memory observers: Common Rail application; Diagnostic des systemes a l'aide d'observateurs a memoire finie: application au Common Rail

    Energy Technology Data Exchange (ETDEWEB)

    Graton, G.

    2005-12-15

    The aim of this work was to propose a fault detection method on the high pressure direct injection system (called Common Rail system) set up on Diesel vehicles. The importance of the fault detection procedure implementation was highlighted thanks to the description of the stakes (lowers consumption, reduction in the pollutant emissions and sound, increase of performances) and constraints dependent on Common Rail (high pressure, high frequency, gas oil lubrication, high precision machining, standards EURO respect,...) but also through a listing of failures which can occur on Common Rail. A synthesis on the different diagnosis methods of systems contributed to select a fault detection method with expected performances (detection of fault beginning, detection speed, isolation and characterization of detected fault and minimizing false alarm and bad detections). After a detailed study (properties, sequential formulations and sensitivity study) of the selected detection method (finite memory observers) and a modeling of the Common Rail various bodies behavior, the algorithm of detection was tested on three different models of the system Common Rail. Moreover, the comparison between the finite memory observer and a Luenberger observer and a Kalman filter allow to appreciate the residual robustness degree. Obtained results allow to conclude on good detection of actuator and sensor faults. (author)

  15. Comparability and repeatability of three commonly used methods for measuring endurance capacity.

    Science.gov (United States)

    Baxter-Gilbert, James; Mühlenhaupt, Max; Whiting, Martin J

    2017-12-01

    Measures of endurance (time to exhaustion) have been used to address a wide range of questions in ecomorphological and physiological research, as well as being used as a proxy for survival and fitness. Swimming, stationary (circular) track running, and treadmill running are all commonly used methods for measuring endurance. Despite the use of these methods across a broad range of taxa, how comparable these methods are to one another, and whether they are biologically relevant, is rarely examined. We used Australian water dragons (Intellagama lesueurii), a species that is morphologically adept at climbing, swimming, and running, to compare these three methods of endurance and examined if there is repeatability within and between trial methods. We found that time to exhaustion was not highly repeatable within a method, suggesting that single measures or a mean time to exhaustion across trials are not appropriate. Furthermore, we compared mean maximal endurance times among the three methods, and found that the two running methods (i.e., stationary track and treadmill) were similar, but swimming was distinctly different, resulting in lower mean maximal endurance times. Finally, an individual's endurance rank was not repeatable across methods, suggesting that the three endurance trial methods are not providing similar information about an individual's performance capacity. Overall, these results highlight the need to carefully match a measure of performance capacity with the study species and the research questions being asked so that the methods being used are behaviorally, ecologically, and physiologically relevant. © 2018 Wiley Periodicals, Inc.

  16. Combined Common Person and Common Item Equating of Medical Science Examinations.

    Science.gov (United States)

    Kelley, Paul R.

    This equating study of the National Board of Medical Examiners Examinations was a combined common persons and common items equating, using the Rasch model. The 1,000-item test was administered to about 3,000 second-year medical students in seven equal-length subtests: anatomy, physiology, biochemistry, pathology, microbiology, pharmacology, and…

  17. Application of the X-in-the-Loop Testing Method in the FCV Hybrid Degree Test

    Directory of Open Access Journals (Sweden)

    Haiyu Gao

    2018-02-01

    Full Text Available With the development of fuel cell vehicle technology, an effective testing method that can be applied to develop and verify the fuel cell vehicle powertrain system is urgently required. This paper presents the X-in-the-Loop (XiL testing method in the fuel cell vehicle (FCV hybrid degree test to resolve the first and key issues for the powertrain system design, and the test process and scenarios were designed. The hybrid degree is redefined into the static hybrid degree for system architecture design and the dynamic hybrid degree for vehicle control strategy design, and an integrated testing platform was introduced and a testing application was implemented by following the designed testing flowchart with two loops. Experimental validations show that the sizing of the FCE (Fuel Cell Engine, battery pack, and traction motor with the powertrain architecture can be determined, the control strategy can be evaluated seamlessly, and a systematic powertrain testing solution can be achieved through the whole development process. This research has developed a new testing platform and proposed a novel testing method on the fuel cell vehicle powertrain system, which will be a contribution to fuel cell vehicle technology and its industrialization.

  18. Best methods for evaluating educational impact: a comparison of the efficacy of commonly used measures of library instruction.

    Science.gov (United States)

    Schilling, Katherine; Applegate, Rachel

    2012-10-01

    Libraries are increasingly called upon to demonstrate student learning outcomes and the tangible benefits of library educational programs. This study reviewed and compared the efficacy of traditionally used measures for assessing library instruction, examining the benefits and drawbacks of assessment measures and exploring the extent to which knowledge, attitudes, and behaviors actually paralleled demonstrated skill levels. An overview of recent literature on the evaluation of information literacy education addressed these questions: (1) What evaluation measures are commonly used for evaluating library instruction? (2) What are the pros and cons of popular evaluation measures? (3) What are the relationships between measures of skills versus measures of attitudes and behavior? Research outcomes were used to identify relationships between measures of attitudes, behaviors, and skills, which are typically gathered via attitudinal surveys, written skills tests, or graded exercises. Results provide useful information about the efficacy of instructional evaluation methods, including showing significant disparities between attitudes, skills, and information usage behaviors. This information can be used by librarians to implement the most appropriate evaluation methods for measuring important variables that accurately demonstrate students' attitudes, behaviors, or skills.

  19. Evaluation of the Thermo Scientific SureTect Salmonella species assay. AOAC Performance Tested Method 051303.

    Science.gov (United States)

    Cloke, Jonathan; Clark, Dorn; Radcliff, Roy; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-01-01

    The Thermo Scientific SureTect Salmonella species Assay is a new real-time PCR assay for the detection of Salmonellae in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Salmonella species Assay in comparison to the reference method detailed in International Organization for Standardization 6579:2002 in a variety of food matrixes, namely, raw ground beef, raw chicken breast, raw ground pork, fresh bagged lettuce, pork frankfurters, nonfat dried milk powder, cooked peeled shrimp, pasteurized liquid whole egg, ready-to-eat meal containing beef, and stainless steel surface samples. With the exception of liquid whole egg and fresh bagged lettuce, which were tested in-house, all matrixes were tested by Marshfield Food Safety, Marshfield, WI, on behalf of Thermo Fisher Scientific. In addition, three matrixes (pork frankfurters, lettuce, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled laboratory study by the University of Guelph, Canada. No significant difference by probability of detection or McNemars Chi-squared statistical analysis was found between the candidate or reference methods for any of the food matrixes or environmental surface samples tested during the validation study. Inclusivity and exclusivity testing was conducted with 117 and 36 isolates, respectively, which demonstrated that the SureTect Salmonella species Assay was able to detect all the major groups of Salmonella enterica subspecies enterica (e.g., Typhimurium) and the less common subspecies of S. enterica (e.g., arizoniae) and the rarely encountered S. bongori. None of the exclusivity isolates analyzed were detected by the SureTect Salmonella species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation (enrichment time

  20. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Science.gov (United States)

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  1. Comparison of Disk Diffusion and E-Test Methods for Doripenem Susceptibility of Nosocomial Acinetobacter Baumannii Strains

    Directory of Open Access Journals (Sweden)

    Yesim Cekin

    2014-03-01

    Full Text Available Aim: Acinetobacter species are amoung the most common two cause of infections isolated from patients of intensive care unit in our hospital. Doripenem which acts by inhibiting cell wall synthesis is resently introduced for use in our country is broad spectrum antibiotic belonging to carbapenems. There are many studies investigating the susceptibility of doripenem of Acinetobacter baumannii which is isolated as a cause of ventilatory associated pneumonia in the literature. We aimed to compare e-test and disc diffusion methods for doripenem susceptibility of acinetobacter baumannii strains as nosocomial infections Acinetobacter baumanni isolates detected as nosocomial infection. Material and Method:. Between January to December, 2009 a total of 94 Acinetobacter baumanni strains isolated from different clinical specimens from intensive care units have been studied for doripenem susceptibility by disc diffusion and E-test methods. Minimal inhibitory consantrations (MIC were accepted as; sensitive %u22641 %u03BCg/ml, intermadiate 2-4 %u03BCg/ml, resistant >4 %u03BCg/ml and diameters of inhibition zone with 10 µg disc; sensitive

  2. Variation and Commonality in Phenomenographic Research Methods

    Science.gov (United States)

    Akerlind, Gerlese S.

    2012-01-01

    This paper focuses on the data analysis stage of phenomenographic research, elucidating what is involved in terms of both commonality and variation in accepted practice. The analysis stage of phenomenographic research is often not well understood. This paper helps to clarify the process, initially by collecting together in one location the more…

  3. Comments on Thermal Physical Properties Testing Methods of Phase Change Materials

    Directory of Open Access Journals (Sweden)

    Jingchao Xie

    2013-01-01

    Full Text Available There is no standard testing method of the thermal physical properties of phase change materials (PCM. This paper has shown advancements in this field. Developments and achievements in thermal physical properties testing methods of PCM were commented, including differential scanning calorimetry, T-history measurement, the water bath method, and differential thermal analysis. Testing principles, advantages and disadvantages, and important points for attention of each method were discussed. A foundation for standardized testing methods for PCM was made.

  4. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  5. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  6. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    Science.gov (United States)

    Silva, F.; Sousa, S. P. B.; Arezes, P.; Swuste, P.; Ribeiro, M. C. S.; Baptista, J. S.

    2015-05-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health & Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field.

  7. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    International Nuclear Information System (INIS)

    Silva, F; Sousa, S P B; Ribeiro, M C S; Arezes, P; Swuste, P; Baptista, J S

    2015-01-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health and Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field. (paper)

  8. 49 CFR Appendix B to Part 178 - Alternative Leakproofness Test Methods

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Alternative Leakproofness Test Methods B Appendix... FOR PACKAGINGS Pt. 178, App. B Appendix B to Part 178—Alternative Leakproofness Test Methods In addition to the method prescribed in § 178.604 of this subchapter, the following leakproofness test methods...

  9. Usage of capillary electrophoresis for common hemoglobinopathies screening

    Directory of Open Access Journals (Sweden)

    Alireza Ebrahimi

    2016-06-01

    Full Text Available Hemoglobinopathies are most common inherited disorders in the world; approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. The hemoglobin disorders inherit as autosomal recessive and are very common in the Mediterranean area and much of the Asia and Africa. The control of this inherited disorders need to genetic counseling and accurate screening by more advanced and more accurate methods. This study explains features of current Iran hemoglobin disorders, nominates the accessible methods for screening them and introduces the capillary zone electrophoresis as a rapid and more accurate method. The required data were extracted of various articles and then for good explanation, current Iran hemoglobinopathies properties were showed in the tables and electropherograms of important hemoglobin disorders in Iran population were provided for help to interpretation results of blood tests by capillary zone electrophoresis method. Hemoglobin disorders are including thalassemias and hemoglobin variants; Disruption in the production and malfunction of globin chains cause types of hemoglobin disorders. We cannot introduce one of clinical laboratory tests as critical and basic method for screening and distinguishing types of inherited hemoglobin disorders as alone. For distinguishing the types of them must be prepared enough information and data of the hemoglobin disorders and for more accurate analysis must be used simultaneously different methods as gel electrophoresis, high performance liquid chromatography, isoelectric focusing, capillary zone electrophoresis or molecular tests. The capillary electrophoresis is an accurate and rapid method for screening types of the hemoglobin disorders. Other side this method cannot analyze all of them, so must be used biochemical, biophysical and molecular methods for confirmation the results. This review showed we can use the capillary electrophoresis and HPLC as two

  10. New methods of testing nonlinear hypothesis using iterative NLLS estimator

    Science.gov (United States)

    Mahaboob, B.; Venkateswarlu, B.; Mokeshrayalu, G.; Balasiddamuni, P.

    2017-11-01

    This research paper discusses the method of testing nonlinear hypothesis using iterative Nonlinear Least Squares (NLLS) estimator. Takeshi Amemiya [1] explained this method. However in the present research paper, a modified Wald test statistic due to Engle, Robert [6] is proposed to test the nonlinear hypothesis using iterative NLLS estimator. An alternative method for testing nonlinear hypothesis using iterative NLLS estimator based on nonlinear hypothesis using iterative NLLS estimator based on nonlinear studentized residuals has been proposed. In this research article an innovative method of testing nonlinear hypothesis using iterative restricted NLLS estimator is derived. Pesaran and Deaton [10] explained the methods of testing nonlinear hypothesis. This paper uses asymptotic properties of nonlinear least squares estimator proposed by Jenrich [8]. The main purpose of this paper is to provide very innovative methods of testing nonlinear hypothesis using iterative NLLS estimator, iterative NLLS estimator based on nonlinear studentized residuals and iterative restricted NLLS estimator. Eakambaram et al. [12] discussed least absolute deviation estimations versus nonlinear regression model with heteroscedastic errors and also they studied the problem of heteroscedasticity with reference to nonlinear regression models with suitable illustration. William Grene [13] examined the interaction effect in nonlinear models disused by Ai and Norton [14] and suggested ways to examine the effects that do not involve statistical testing. Peter [15] provided guidelines for identifying composite hypothesis and addressing the probability of false rejection for multiple hypotheses.

  11. 77 FR 8865 - Recent Postings of Broadly Applicable Alternative Test Methods

    Science.gov (United States)

    2012-02-15

    ... Applicable Alternative Test Methods AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This notice announces the broadly applicable alternative test method approval decisions... INFORMATION CONTACT: An electronic copy of each alternative test method approval document is available on the...

  12. Overview of multi-input frequency domain modal testing methods with an emphasis on sine testing

    Science.gov (United States)

    Rost, Robert W.; Brown, David L.

    1988-01-01

    An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.

  13. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  14. Validation of qualitative microbiological test methods

    NARCIS (Netherlands)

    IJzerman-Boon, Pieta C.; van den Heuvel, Edwin R.

    2015-01-01

    This paper considers a statistical model for the detection mechanism of qualitative microbiological test methods with a parameter for the detection proportion (the probability to detect a single organism) and a parameter for the false positive rate. It is demonstrated that the detection proportion

  15. 46 CFR 57.06-3 - Method of performing production testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Method of performing production testing. 57.06-3 Section 57.06-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Production Tests § 57.06-3 Method of performing production testing. (a) Except as...

  16. Test reactor risk assessment methodology

    International Nuclear Information System (INIS)

    Jennings, R.H.; Rawlins, J.K.; Stewart, M.E.

    1976-04-01

    A methodology has been developed for the identification of accident initiating events and the fault modeling of systems, including common mode identification, as these methods are applied in overall test reactor risk assessment. The methods are exemplified by a determination of risks to a loss of primary coolant flow in the Engineering Test Reactor

  17. Moisture distribution in sludges based on different testing methods

    Institute of Scientific and Technical Information of China (English)

    Wenyi Deng; Xiaodong Li; Jianhua Yan; Fei Wang; Yong Chi; Kefa Cen

    2011-01-01

    Moisture distributions in municipal sewage sludge, printing and dyeing sludge and paper mill sludge were experimentally studied based on four different methods, i.e., drying test, thermogravimetric-differential thermal analysis (TG-DTA) test, thermogravimetricdifferential scanning calorimetry (TG-DSC) test and water activity test. The results indicated that the moistures in the mechanically dewatered sludges were interstitial water, surface water and bound water. The interstitial water accounted for more than 50% wet basis (wb) of the total moisture content. The bond strength of sludge moisture increased with decreasing moisture content, especially when the moisture content was lower than 50% wb. Furthermore, the comparison among the four different testing methods was presented.The drying test was advantaged by its ability to quantify free water, interstitial water, surface water and bound water; while TG-DSC test, TG-DTA test and water activity test were capable of determining the bond strength of moisture in sludge. It was found that the results from TG-DSC and TG-DTA test are more persuasive than water activity test.

  18. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  19. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha......In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method...

  20. Testing three common stocking methods: Differences in smolt size, migration rate and timing of two strains of stocked Atlantic salmon ( Salmo salar )

    DEFF Research Database (Denmark)

    Birnie-Gauvin, Kim; Larsen, Martin Hage; Thomassen, Søren T.

    2018-01-01

    The influence of three common stocking practices for two strains (Ätran and Burrishoole) of hatchery-reared Atlantic salmon, Salmo salar, on smolt size, migration probability and migration timing were investigated in situ. Using a common garden experiment, fish from these populations were release...... to inherited factors, and emphasize the importance of considering age of fish and time spent in the hatchery when stocking populations in the wild to maximize smolt output......The influence of three common stocking practices for two strains (Ätran and Burrishoole) of hatchery-reared Atlantic salmon, Salmo salar, on smolt size, migration probability and migration timing were investigated in situ. Using a common garden experiment, fish from these populations were released...... as fry, half-year olds and oneyear olds. Our results indicate that fish released at the fry and half-year stage produce smaller smolts, and migrate later in the year than their counterparts released at one-year of age, for both the Ätran and the Burrishoole populations. While fry had the lowest...

  1. Supplementary test method for carbon filters

    International Nuclear Information System (INIS)

    Normann, B.; Pettersson, S.-O.

    1980-11-01

    A test method for carbon filters using freon to detect leakage is described. The filters are used in nuclear power plants and in air-raid shelters to separate radioactive iodine.Sampling and detection limits are described and a proposal for a complete equipment is made.(G.B.)

  2. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    Science.gov (United States)

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  3. Method of measurement on materials shielding effectiveness test in time domain

    International Nuclear Information System (INIS)

    Liu Shunkun; Han Jun; Chen Xiangyue

    2009-01-01

    Windows method is a measurement of slot coupling effect in nature when it is used to measure material's shielding effectiveness. The error of measurement will become serious when it is used to measure material's shielding effectiveness in low frequency band. It is difficult to measure material's shielding effectiveness of electromagnetic pulse with Windows method. Device under test method (DUT method) was presented in this paper to overcome the limitations of Windows method in material's shielding effectiveness test. The method can be used to measure any material's shielding Effectiveness effectively through the design and the test of the DUT.The method was used to measure shielding effectiveness of special cement .Compared with theoretical analysis,the measurement result prove the DUT method to be very efficient in material's shielding effectiveness test. (authors)

  4. Calculation of Core Damage Frequency for the Change of the Common Cause Failure Parameters According to the Testing Strategies

    International Nuclear Information System (INIS)

    Kang, Dae Il; Kim, Kil You; Jin, Young Ho; Kim, Tae Woon

    2011-01-01

    Common cause failure (CCF) probabilities are differently estimated according to testing strategies. There are two representative testing schemes; staggered testing and non-staggered testing schemes. For the cases where trains or channels of standby safety systems consisting of more than two redundant components are tested in a staggered manner, the standby safety components within a train can be tested simultaneously or consecutively. In this case, mixed testing scheme, staggered and non-staggered testing schemes, are used for testing the components. Kang et al. derived the formulas for the estimations of the CCF probabilities of the components under the mixed testing scheme. This paper presents the sensitivity study results on the core damage frequency (CDF) of the SMART (System-integrated Modular Advanced Reactor) for the changes of the CCF parameters according to the testing strategies

  5. Characterization methods for ultrasonic test systems

    International Nuclear Information System (INIS)

    Busse, L.J.; Becker, F.L.; Bowey, R.E.; Doctor, S.R.; Gribble, R.P.; Posakony, G.J.

    1982-07-01

    Methods for the characterization of ultrasonic transducers (search units) and instruments are presented. The instrument system is considered as three separate components consisting of a transducer, a receiver-display, and a pulser. The operation of each component is assessed independently. The methods presented were chosen because they provide the greatest amount of information about component operation and were not chosen based upon such conditions as cost, ease of operation, field implementation, etc. The results of evaluating a number of commercially available ultrasonic test instruments are presented

  6. Standard practice for digital imaging and communication in nondestructive evaluation (DICONDE) for ultrasonic test methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice facilitates the interoperability of ultrasonic imaging equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This document is intended to be used in conjunction with Practice E 2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E 2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, transfer and archival storage. The goal of Practice E 2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE test results on any system conforming to the DICONDE standard. Toward that end, Practice E 2339 provides a data dictionary and set of information modules that are applicable to all NDE modalities. This practice supplements Practice E 2339 by providing information object definitions, information ...

  7. Acute sensitivity of freshwater mollusks and commonly tested invertebrates to select chemicals with different toxic models of action

    Science.gov (United States)

    Previous studies indicate that freshwater mollusks are more sensitive than commonly tested organisms to some chemicals, such as copper and ammonia. Nevertheless, mollusks are generally under-represented in toxicity databases. Studies are needed to generate data with which to comp...

  8. Abandoning the common law: medical negligence, genetic tests and wrongful life in the Australian High Court.

    Science.gov (United States)

    Faunce, Thomas; Jefferys, Susannah

    2007-05-01

    The Australian High Court recently found that the common law could allow parents to claim tortious damages when medical negligence was proven to have led to the birth of an unplanned, but healthy, baby (Cattanach v Melchior (2003) 215 CLR 1). In Harriton v Stephens (2006) 80 ALJR 791; [2006] HCA 15 and Waller v James; Waller v Hoolahan (2006) 80 ALJR 846; [2006] HCA 16 the High Court in a six-to-one decision (Kirby J dissenting) decided that no such claim could be made by a child when medical negligence in failing to order an in utero genetic test caused the child severe disability. In an era when almost all pregnancies will soon require patented fetal genetic tests as part of the professional standard of care, the High Court, by barring so-called "wrongful life" (better termed "wrongful suffering") claims, may have created a partial immunity from suit for their corporate manufacturers and the doctors who administer them. What lessons can be learnt from this case about how the Australian High Court is, or should be, approaching medical negligence cases and its role as guardian of the Australian common law?

  9. Standard Guide for Testing Polymer Matrix Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide summarizes the application of ASTM standard test methods (and other supporting standards) to continuous-fiber reinforced polymer matrix composite materials. The most commonly used or most applicable ASTM standards are included, emphasizing use of standards of Committee D30 on Composite Materials. 1.2 This guide does not cover all possible standards that could apply to polymer matrix composites and restricts discussion to the documented scope. Commonly used but non-standard industry extensions of test method scopes, such as application of static test methods to fatigue testing, are not discussed. A more complete summary of general composite testing standards, including non-ASTM test methods, is included in the Composite Materials Handbook (MIL-HDBK-17). Additional specific recommendations for testing textile (fabric, braided) composites are contained in Guide D6856. 1.3 This guide does not specify a system of measurement; the systems specified within each of the referenced standards shall appl...

  10. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  11. Standard Test Methods for Photovoltaic Modules in Cyclic Temperature and Humidity Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods provide procedures for stressing photovoltaic modules in simulated temperature and humidity environments. Environmental testing is used to simulate aging of module materials on an accelerated basis. 1.2 Three individual environmental test procedures are defined by these test methods: a thermal cycling procedure, a humidity-freeze cycling procedure, and an extended duration damp heat procedure. Electrical biasing is utilized during the thermal cycling procedure to simulate stresses that are known to occur in field-deployed modules. 1.3 These test methods define mounting methods for modules undergoing environmental testing, and specify parameters that must be recorded and reported. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 Any of the individual environmental tests may be performed singly, or may be combined into a test sequence with other environmental or non-envir...

  12. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  13. Nonlinear Parameter Estimation in Microbiological Degradation Systems and Statistic Test for Common Estimation

    DEFF Research Database (Denmark)

    Sommer, Helle Mølgaard; Holst, Helle; Spliid, Henrik

    1995-01-01

    Three identical microbiological experiments were carried out and analysed in order to examine the variability of the parameter estimates. The microbiological system consisted of a substrate (toluene) and a biomass (pure culture) mixed together in an aquifer medium. The degradation of the substrate...... and the growth of the biomass are described by the Monod model consisting of two nonlinear coupled first-order differential equations. The objective of this study was to estimate the kinetic parameters in the Monod model and to test whether the parameters from the three identical experiments have the same values....... Estimation of the parameters was obtained using an iterative maximum likelihood method and the test used was an approximative likelihood ratio test. The test showed that the three sets of parameters were identical only on a 4% alpha level....

  14. Test methods for determining asphaltene stability in crude oils

    Energy Technology Data Exchange (ETDEWEB)

    Asomaning, S. [Baker Petrolite, Sugar Land, TX (United States)

    2001-07-01

    The development of test methods for the determination of the stability of asphaltenes in crude oils was rendered necessary, due to the high cost of remediating asphaltene deposition in harsh production environments, namely the underwater systems in offshore deepwater. The Oliensis Spot Test, two saturates, aromatics, resins and asphaltenes (SARA)-based screens (the Colloidal Instability Index and Asphaltene-Resin ratio), a solvent titration method with near infrared radiation (NIR) solids detection, and live oil depressurization were used for the purposes of this study, to predict the stability of asphaltenes in crude oils with different API gravity. A complete description of the test methods was provided, and the experimental data obtained as a result was presented. Correlation with data on the deposition histories of the oils was used to validate the experimental stability data. The author discussed the effectiveness of the different tests for the prediction of the stability of asphaltenes in crude oils. The prediction of a crude oil's propensity towards asphaltene precipitation was more accurate with the Colloidal Instability Index and the solvent titration method. Live oil depressurization proved to be very effective for the prediction of the stability of asphaltenes for light oils, where most stability tests fail. tabs., 31 figs.

  15. Relationship between Processing Method and the Glycemic Indices of Ten Sweet Potato (Ipomoea batatas Cultivars Commonly Consumed in Jamaica

    Directory of Open Access Journals (Sweden)

    Perceval S. Bahado-Singh

    2011-01-01

    Full Text Available This study investigated the effect of different traditional cooking methods on glycemic index (GI and glycemic response of ten Sweet potato (Ipomoea batatas cultivars commonly eaten in Jamaica. Matured tubers were cooked by roasting, baking, frying, or boiling then immediately consumed by the ten nondiabetic test subjects (5 males and 5 females; mean age of 27 ± 2 years. The GI varied between 41 ± 5–93 ± 5 for the tubers studied. Samples prepared by boiling had the lowest GI (41 ± 5–50 ± 3, while those processed by baking (82 ± 3–94 ± 3 and roasting (79 ± 4–93 ± 2 had the highest GI values. The study indicates that the glycemic index of Jamaican sweet potatoes varies significantly with the method of preparation and to a lesser extent on intravarietal differences. Consumption of boiled sweet potatoes could minimize postprandial blood glucose spikes and therefore, may prove to be more efficacious in the management of type 2 diabetes mellitus.

  16. A comprehensive review of regulatory test methods for endocrine adverse health effects.

    Science.gov (United States)

    Manibusan, M K; Touart, L W

    2017-07-01

    Development of new endocrine disruption-relevant test methods has been the subject of intensive research efforts for the past several decades, prompted in part by mandates in the 1996 Food Quality Protection Act (FQPA). While scientific understanding and test methods have advanced, questions remain on whether current scientific methods are capable of adequately addressing the complexities of the endocrine system for regulatory health and ecological risk assessments. The specific objective of this article is to perform a comprehensive, detailed evaluation of the adequacy of current test methods to inform regulatory risk assessments of whether a substance has the potential to perturb endocrine-related pathways resulting in human adverse effects. To that end,  approximately 42 existing test guidelines (TGs) were considered in the evaluation of coverage for endocrine-related adverse effects. In addition to evaluations of whether test methods are adequate to capture endocrine-related effects, considerations of further enhancements to current test methods, along with the need to develop novel test methods to address existing test method gaps are described. From this specific evaluation, up to 35 test methods are capable of informing whether a chemical substance perturbs known endocrine related biological pathways. Based on these findings, it can be concluded that current validated test methods are adequate to discern substances that may perturb the endocrine system, resulting in an adverse health effect. Together, these test methods predominantly form the core data requirements of a typical food-use pesticide registration submission. It is recognized, however, that the current state of science is rapidly advancing and there is a need to update current test methods to include added enhancements to ensure continued coverage and public health and environmental protection.

  17. Leak test method for radioactive material packagings without pressure valve connections

    International Nuclear Information System (INIS)

    Johnson, S.F.; Stenbaeck, A.

    1976-01-01

    A leak test method has been developed at Studsvik which provides the possibility of testing Type B packagings unequipped with valves for evacuation or pressurizing. Even large packagings with pressure valve connections can be leak tested by this method. The method is a pressure test method. The test gas comprises a mixture of helium and nitrogen or helium and air. Excess pressure in a valveless packaging is achieved by vaporization of liquid nitrogen. All parts of the packaging or package where leaks might be expected are covered by plastic sheet. Samples of the gas accumulated under the plastic sheets are taken using evacuated glass ampoules which are initially sealed off to a breakable point. The gas samples are measured with a He-mass spectrometer. The sensitivity of this method of leak testing is, in practice, of the order of 10 -7 atmcm 3 s -1 . (author)

  18. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  19. "Comparison of some Structural Analyses Methods used for the Test Pavement in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Baltzer, S.; Zhang, W.; Macdonald, R.

    1998-01-01

    A flexible test pavement, instrumented to measure stresses and strains in the three primary axes with the upper 400 mm of the subgrade, has been constructed and load tested in the Danish Road Testing Machine (RTM). One objective of this research, which is part of the International Pavement Subgrade...... Pressure Cells, Thermistors and Pore Pressure Sensors. Routine monitoring of instrument responses and surface profiles with a Profilometer and FWD/LWD structural testing were undertaken at regular intervals during the construction and load testing programmes.This paper compares various structural analysis...... methods used for the RTM test pavement with data from FWD testing undertaken after the construction and loading programmes. Multilayer linear elastic forward and backcalculation methods, a finite element program and MS Excel spreadsheet based methods are compared....

  20. testing a consensus conference method by discussing

    African Journals Online (AJOL)

    hi-tech

    2000-10-10

    Oct 10, 2000 ... Objectives: To test the recommended consensus conference methods in Tanzania by discussing the management ... “wrong”, based on recommendations advocated in western ..... future scenarios sponsored the conference.

  1. Test Methods for Effects on Organisms:Springtails

    OpenAIRE

    Krogh, P. H.

    1997-01-01

    NORD-UTTE er Nordisk koordineringsgrupp för utvekling av testmetoder inom toxicologi och ekotoxicology. The Nordic Co-ordination Group for the Development of Test Methods for Toxicology and Ecotoxicology

  2. Accelerated Test Method for Corrosion Protective Coatings

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as...

  3. On the assessment of usability testing methods for children

    NARCIS (Netherlands)

    Markopoulos, P.; Bekker, M.M.

    2003-01-01

    The paper motivates the need to acquire methodological knowledge for involving children as test users in usability testing. It introduces a methodological framework for delineating comparative assessments of usability testing methods for children participants. This framework consists in three

  4. Inverse modelling of aquifer parameters in basaltic rock with the help of pumping test method using MODFLOW software

    Directory of Open Access Journals (Sweden)

    Kanak Moharir

    2017-11-01

    The present study of estimation of aquifer factors such as transmissivity (T and storativity (S are vital for the evaluation of groundwater resources. There are several methods to estimate the accurate aquifer parameters (i.e. hydrograph analysis, pumping test, etc.. In initial days, these parameters are projected either by means of in-situ test or execution test on aquifer well samples carried in the laboratory. The simultaneous information on the hydraulic behavior of the well (borehole that provides on this method, the reservoir and the reservoir boundaries, are important for efficient aquifer and well data management and analysis. The most common in-situ test is pumping test performed on wells, which involves the measurement of the fall and increase of groundwater level with respect to time. The alteration in groundwater level (drawdown/recovery is caused due to pumping of water from the well. Theis (1935 was first to propose method to evaluate aquifer parameters from the pumping test on a bore well in a confined aquifer. It is essential to know the transmissivity (T = Kb, where b is the aquifer thickness; pumping flow rate, Q = TW (dh/dl flow through an aquifer and storativity (confined aquifer: S = bSs, unconfined: S = Sy, for the characterization of the aquifer parameters in an unknown area so as to predict the rate of drawdown of the groundwater table/potentiometric surface throughout the pumping test of an aquifer. The determination of aquifer's parameters is an important basis for groundwater resources evaluation, numerical simulation, development and protection as well as scientific management. For determining aquifer's parameters, pumping test is a main method. A case study shows that these techniques have been fast speed and high correctness. The results of parameter's determination are optimized so that it has important applied value for scientific research and geology engineering preparation.

  5. Testing and Validation of the Dynamic Interia Measurement Method

    Science.gov (United States)

    Chin, Alexander; Herrera, Claudia; Spivey, Natalie; Fladung, William; Cloutier, David

    2015-01-01

    This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.

  6. Comparison of E-test with other conventional susceptibility testing methods for ciprofloxacin and gentamicin against gram negative enteric bacilli.

    Science.gov (United States)

    Ogbolu, D O; Terry-Alli, O A; Daini, O A; Olabiyi, F A; Igharo, E A

    2012-06-01

    Increasing antibiotic resistance in Gram negative bacteria has led to the need for a faster and reliable method for determining antimicrobial susceptibility testing. In a resource poor setting like ours, it's also important to look for methods that will be clinically and economically beneficial to the patient. This study was aimed at evaluating the Epsilometer test (E-test) and conventional methods for determining antimicrobial susceptibility of isolates of Gram-negative enteric bacteria to ciprofloxacin and gentamicin. Disc diffusion, E-test, broth dilution and agar dilution methods were performed on 54 bacterial isolates. Using the E-test, 88.9% of bacterial isolates were resistant to ciprofloxacin, 92.6% were resistant using broth microdilution, 96.3% were resistant using agar dilution and 72.2% were resistant using disc diffusion. Minimum inhibitory concentration (MIC50) of isolates for gentamicin showed significant difference for all the techniques (p 0.05). Both E-test and broth dilution methods showed high levels of agreement (p > 0.05), there were low levels of agreement between E-test and agar dilution method (p < 0.05), especially at MIC50. The E-test can therefore be considered a reliable method to determine antimicrobial susceptibility testing and it gives results which are at least as accurate as those obtained by the broth dilution method.

  7. Satellite Vibration Testing: Angle optimisation method to Reduce Overtesting

    Science.gov (United States)

    Knight, Charly; Remedia, Marcello; Aglietti, Guglielmo S.; Richardson, Guy

    2018-06-01

    Spacecraft overtesting is a long running problem, and the main focus of most attempts to reduce it has been to adjust the base vibration input (i.e. notching). Instead this paper examines testing alternatives for secondary structures (equipment) coupled to the main structure (satellite) when they are tested separately. Even if the vibration source is applied along one of the orthogonal axes at the base of the coupled system (satellite plus equipment), the dynamics of the system and potentially the interface configuration mean the vibration at the interface may not occur all along one axis much less the corresponding orthogonal axis of the base excitation. This paper proposes an alternative testing methodology in which the testing of a piece of equipment occurs at an offset angle. This Angle Optimisation method may have multiple tests but each with an altered input direction allowing for the best match between all specified equipment system responses with coupled system tests. An optimisation process that compares the calculated equipment RMS values for a range of inputs with the maximum coupled system RMS values, and is used to find the optimal testing configuration for the given parameters. A case study was performed to find the best testing angles to match the acceleration responses of the centre of mass and sum of interface forces for all three axes, as well as the von Mises stress for an element by a fastening point. The angle optimisation method resulted in RMS values and PSD responses that were much closer to the coupled system when compared with traditional testing. The optimum testing configuration resulted in an overall average error significantly smaller than the traditional method. Crucially, this case study shows that the optimum test campaign could be a single equipment level test opposed to the traditional three orthogonal direction tests.

  8. What Happened to Remote Usability Testing? An Empirical Study of Three Methods

    DEFF Research Database (Denmark)

    Stage, Jan; Andreasen, M. S.; Nielsen, H. V.

    2007-01-01

    The idea of conducting usability tests remotely emerged ten years ago. Since then, it has been studied empirically, and some software organizations employ remote methods. Yet there are still few comparisons involving more than one remote method. This paper presents results from a systematic...... empirical comparison of three methods for remote usability testing and a conventional laboratorybased think-aloud method. The three remote methods are a remote synchronous condition, where testing is conducted in real time but the test monitor is separated spatially from the test subjects, and two remote...

  9. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  10. Application of WST-method fore fracture testing of fibre-reinforced concrete

    DEFF Research Database (Denmark)

    Löfgren, Ingemar; Olesen, John Forbes; Flansbjer, Mathias

    be drawn from this study are that: § the wedge-splitting test method is a suitable test method for assessment of fracture properties of steel fibre-reinforced concrete; § the test method is easy to handle and relatively fast to execute § the test can be run with CMOD-control or without, in a machine...... more than three times the fibre length; § using inverse analysis, the tensile fracture properties can be interpreted from the test result as a bi-linear stress-crack opening relationship.......To evaluate the reproducibility of the wedge-splitting test method and to provide guidelines, a round robin study was conducted in which three labs participated. The participating labs were: § DTU – the Technical University of Denmark, Department of Civil Engineering; § CTH – Chalmers University...

  11. Standard test method for nondestructive assay of special nuclear material in low density scrap and waste by segmented passive gamma-Ray scanning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the transmission-corrected nondestructive assay (NDA) of gamma-ray emitting special nuclear materials (SNMs), most commonly 235U, 239Pu, and 241Am, in low-density scrap or waste, packaged in cylindrical containers. The method can also be applied to NDA of other gamma-emitting nuclides including fission products. High-resolution gamma-ray spectroscopy is used to detect and measure the nuclides of interest and to measure and correct for gamma-ray attenuation in a series of horizontal segments (collimated gamma detector views) of the container. Corrections are also made for counting losses occasioned by signal processing limitations (1-3). 1.2 There are currently several systems in use or under development for determining the attenuation corrections for NDA of radioisotopic materials (4-8). A related technique, tomographic gamma-ray scanning (TGS), is not included in this test method (9, 10, 11). 1.2.1 This test method will cover two implementations of the Segmented Gamma Scanning ...

  12. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    Science.gov (United States)

    2016-12-16

    materials . The results demonstrated that the Midscale test is a quick and cost-effective method for evaluation of FR performance of design features...standard and novel FR materials and design configurations during fire engulfment. Details of the test method and its development can be found in the...employed in the FRACU is a ripstop fabric blend of 65% FR rayon, 25% para- aramid and 10% nylon. The iCVC material is Nylon/Cotton/Nomex. All three

  13. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

  15. Small punch test evaluation methods for material characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Janča, Adam, E-mail: adam.janca@fjfi.cvut.cz; Siegl, Jan, E-mail: jan.siegl@fjfi.cvut.cz; Haušild, Petr, E-mail: petr.hausild@fjfi.cvut.cz

    2016-12-01

    The Small Punch Test (SPT) is one of the most widespread mechanical testing methods using miniaturized specimens. The paper presented deals with the time independent SPT, in which a flat specimen is bent by means of a (hemi)spherical punch moving at a constant velocity. The main goal is to relate the measured data to deformation processes taking place during specimen loading. Understanding of such relations is crucial for characterizing a material using any non-standardized experimental procedure. Using enhanced instrumentation, not only traditional load-displacement or load-deflection curves could be obtained, but also specimen thinning could be continuously measured and evaluated. Five alloys having a broad range of mechanical properties were tested. The results obtained were evaluated using both traditional and newly proposed methods and they were correlated with results of the conventional tensile test. The methods proposed seem to lead to a universal correlation between SPT results and tensile characteristics. - Highlights: • The newly proposed methodology significantly improved results of SPT. • Plastic deformation starts inside the specimen from the very beginning of loading. • Specimen thinning = punch displacement−specimen deflection. • Material response to loading is well illustrated by the novel load-thinning curve.

  16. Measurement environments and testing

    Science.gov (United States)

    Marvin, A. C.

    1991-06-01

    The various methods used to assess both the emission (interference generation) performance of electronic equipment and the immunity of electronic equipment to external electromagnetic interference are described. The measurement methods attempt to simulate realistic operating conditions for the equipment being tested, yet at the same time they must be repeatable and practical to operate. This has led to the development of a variety of test methods, each of which has its limitations. Concentration is on the most common measurement methods such as open-field test sites, screened enclosures and transverse electromagnetic (TEM) cells. The physical justification for the methods, their limitations, and measurement precision are described. Ways of relating similar measurements made by different methods are discussed, and some thoughts on future measurement improvements are presented.

  17. Test equating, scaling, and linking methods and practices

    CERN Document Server

    Kolen, Michael J

    2014-01-01

    This book provides an introduction to test equating, scaling, and linking, including those concepts and practical issues that are critical for developers and all other testing professionals.  In addition to statistical procedures, successful equating, scaling, and linking involves many aspects of testing, including procedures to develop tests, to administer and score tests, and to interpret scores earned on tests. Test equating methods are used with many standardized tests in education and psychology to ensure that scores from multiple test forms can be used interchangeably.  Test scaling is the process of developing score scales that are used when scores on standardized tests are reported. In test linking, scores from two or more tests are related to one another. Linking has received much recent attention, due largely to investigations of linking similarly named tests from different test publishers or tests constructed for different purposes. In recent years, researchers from the education, psychology, and...

  18. PAPI based federation as a test-bed for a common security infrastructure in EFDA sites

    International Nuclear Information System (INIS)

    Castro, R.; Vega, J.; Portas, A.; Lopez, D.R.; Balme, S.; Theis, J.M.; Lebourg, P.; Fernandes, H.; Neto, A.; Duarte, A.; Oliveira, F.; Reis, F.; Purahoo, K.; Thomsen, K.; Schiller, W.; Kadlecsik, J.

    2008-01-01

    Federated authentication and authorization systems provide several advantages to collaborative environments, for example, easy authentication integration, simpler user management, easier security policy implementation and quicker implementation of access control elements for new type of resources. A federation integrates different aspects that have to be coordinated by all the organizations involved. The most relevant are: definition of common schemas and attributes, definition of common policies and procedures, management of keys and certificates, management of common repositories and implementation of a home location service. A federation enabling collaboration of European sites has been put into operation. Four laboratories have been integrated and two more organizations (EFDA and KFKI/HAS) are finishing their integration. The federation infrastructure is based on Point of Access to Providers of Information (PAPI), a distributed authentication and authorization system. PAPI technology gives some important features, such as, single sign on for accessing to different resources, mobility for users, and compatibility with open and standard technologies: Java, JNLP protocol, XML-RPC and web technologies among others. In this article, the test-bed of EFDA federation is presented. Some examples of resources, securely shared inside the federation, are shown. Specific issues and experience gained in deploying federated collaboration systems will be addressed as well

  19. PAPI based federation as a test-bed for a common security infrastructure in EFDA sites

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)], E-mail: rodrigo.castro@ciemat.es; Vega, J.; Portas, A. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); Lopez, D.R. [Departamento RedIRIS, Entidad publica empresarial Red.es, Madrid (Spain); Balme, S.; Theis, J.M.; Lebourg, P. [Association EURATOM-CEA, CEA/DSM/Departement de Recherches sur la Fusion Controlee DRFC, CEA-Cadarache (France); Fernandes, H.; Neto, A.; Duarte, A.; Oliveira, F.; Reis, F. [Centro de Fusao Nuclear, Associacao EURATOM/IST, Lisboa (Portugal); Purahoo, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Thomsen, K.; Schiller, W. [EFDA Close Support Unit Garching, Max Planck Institut fuer Plasmaphysik, Boltzmannstr. 2, D-85748 Garching (Germany); Kadlecsik, J. [KFKI R.I. for Particle and Nuclear Physics of the Hungarian Academy of Sciences, and the Association EURATOM/HAS, Budapest (Hungary)

    2008-04-15

    Federated authentication and authorization systems provide several advantages to collaborative environments, for example, easy authentication integration, simpler user management, easier security policy implementation and quicker implementation of access control elements for new type of resources. A federation integrates different aspects that have to be coordinated by all the organizations involved. The most relevant are: definition of common schemas and attributes, definition of common policies and procedures, management of keys and certificates, management of common repositories and implementation of a home location service. A federation enabling collaboration of European sites has been put into operation. Four laboratories have been integrated and two more organizations (EFDA and KFKI/HAS) are finishing their integration. The federation infrastructure is based on Point of Access to Providers of Information (PAPI), a distributed authentication and authorization system. PAPI technology gives some important features, such as, single sign on for accessing to different resources, mobility for users, and compatibility with open and standard technologies: Java, JNLP protocol, XML-RPC and web technologies among others. In this article, the test-bed of EFDA federation is presented. Some examples of resources, securely shared inside the federation, are shown. Specific issues and experience gained in deploying federated collaboration systems will be addressed as well.

  20. Inhibitory effect of common microfluidic materials on PCR outcome

    KAUST Repository

    Kodzius, Rimantas; Xiao, Kang; Wu, Jinbo; Yi, Xin; Gong, Xiuqing; Foulds, Ian G.; Wen, Weijia

    2013-01-01

    In this study, we established a simple method for evaluating the PCR compatibility of various common materials employed when fabricating microfluidic chips, including silicon, several kinds of silicon oxide, glasses, plastics, wax, and adhesives. Two-temperature PCR was performed with these materials to determine their PCR-inhibitory effect. In most cases, adding bovine serum albumin effectively improved the reaction yield. We also studied the individual PCR components from the standpoint of adsorption. Most of the materials did not inhibit the DNA, although they noticeably interacted with the polymerase. We provide a simple method of performing PCR-compatibility testing of materials using inexpensive instrumentation that is common in molecular biology laboratories. Furthermore, our method is direct, being performed under actual PCR conditions with high temperature. Our results provide an overview of materials that are PCR-friendly for fabricating microfluidic devices. The PCR reaction, without any additives, performed best with pyrex glass, and it performed worst with PMMA or acrylic glue materials.

  1. Inhibitory effect of common microfluidic materials on PCR outcome

    KAUST Repository

    Kodzius, Rimantas

    2013-10-10

    In this study, we established a simple method for evaluating the PCR compatibility of various common materials employed when fabricating microfluidic chips, including silicon, several kinds of silicon oxide, glasses, plastics, wax, and adhesives. Two-temperature PCR was performed with these materials to determine their PCR-inhibitory effect. In most cases, adding bovine serum albumin effectively improved the reaction yield. We also studied the individual PCR components from the standpoint of adsorption. Most of the materials did not inhibit the DNA, although they noticeably interacted with the polymerase. We provide a simple method of performing PCR-compatibility testing of materials using inexpensive instrumentation that is common in molecular biology laboratories. Furthermore, our method is direct, being performed under actual PCR conditions with high temperature. Our results provide an overview of materials that are PCR-friendly for fabricating microfluidic devices. The PCR reaction, without any additives, performed best with pyrex glass, and it performed worst with PMMA or acrylic glue materials.

  2. Testing of abrasion materials

    International Nuclear Information System (INIS)

    Hummert, G.

    1983-01-01

    A method of abrasion testing according to ASTM C 704-76 a is presented for steel fibre concrete mortar, fusion-cast basalt and a surface coating material and results of practical interest are mentioned. Due to the high technical demands on these materials and their specific fields of application, the very first test already supplied interesting findings. From the user's point of view, the method is an interesting alternative to the common test methods, e.g. according to DIN 52 108 (wheel test according to Boehme). In English-speaking countries, testing according to ASTM is often mandatory in the refractory industry in order to assure constant quality of refractory materials after setting. The method is characterized by good comparability and high accuracy of measurement. Only the test piece is exchanged while the test conditions remain constant, so that accurate information on the material studied is obtained. (orig.) [de

  3. Standard test method for drop-weight tear tests of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers drop-weight tear tests (DWTT) on ferritic steels with thicknesses between 3.18 and 19.1 mm. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  5. Relative accuracy of three common methods of parentage analysis in natural populations

    KAUST Repository

    Harrison, Hugo B.; Saenz Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P.; Berumen, Michael L.

    2012-01-01

    Parentage studies and family reconstructions have become increasingly popular for investigating a range of evolutionary, ecological and behavioural processes in natural populations. However, a number of different assignment methods have emerged in common use and the accuracy of each may differ in relation to the number of loci examined, allelic diversity, incomplete sampling of all candidate parents and the presence of genotyping errors. Here, we examine how these factors affect the accuracy of three popular parentage inference methods (colony, famoz and an exclusion-Bayes' theorem approach by Christie (Molecular Ecology Resources, 2010a, 10, 115) to resolve true parent-offspring pairs using simulated data. Our findings demonstrate that accuracy increases with the number and diversity of loci. These were clearly the most important factors in obtaining accurate assignments explaining 75-90% of variance in overall accuracy across 60 simulated scenarios. Furthermore, the proportion of candidate parents sampled had a small but significant impact on the susceptibility of each method to either false-positive or false-negative assignments. Within the range of values simulated, colony outperformed FaMoz, which outperformed the exclusion-Bayes' theorem method. However, with 20 or more highly polymorphic loci, all methods could be applied with confidence. Our results show that for parentage inference in natural populations, careful consideration of the number and quality of markers will increase the accuracy of assignments and mitigate the effects of incomplete sampling of parental populations. © 2012 Blackwell Publishing Ltd.

  6. Relative accuracy of three common methods of parentage analysis in natural populations

    KAUST Repository

    Harrison, Hugo B.

    2012-12-27

    Parentage studies and family reconstructions have become increasingly popular for investigating a range of evolutionary, ecological and behavioural processes in natural populations. However, a number of different assignment methods have emerged in common use and the accuracy of each may differ in relation to the number of loci examined, allelic diversity, incomplete sampling of all candidate parents and the presence of genotyping errors. Here, we examine how these factors affect the accuracy of three popular parentage inference methods (colony, famoz and an exclusion-Bayes\\' theorem approach by Christie (Molecular Ecology Resources, 2010a, 10, 115) to resolve true parent-offspring pairs using simulated data. Our findings demonstrate that accuracy increases with the number and diversity of loci. These were clearly the most important factors in obtaining accurate assignments explaining 75-90% of variance in overall accuracy across 60 simulated scenarios. Furthermore, the proportion of candidate parents sampled had a small but significant impact on the susceptibility of each method to either false-positive or false-negative assignments. Within the range of values simulated, colony outperformed FaMoz, which outperformed the exclusion-Bayes\\' theorem method. However, with 20 or more highly polymorphic loci, all methods could be applied with confidence. Our results show that for parentage inference in natural populations, careful consideration of the number and quality of markers will increase the accuracy of assignments and mitigate the effects of incomplete sampling of parental populations. © 2012 Blackwell Publishing Ltd.

  7. Simplified pressure method for respirator fit testing.

    Science.gov (United States)

    Han, D; Xu, M; Foo, S; Pilacinski, W; Willeke, K

    1991-08-01

    A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

  8. A common base method for analysis of qPCR data and the application of simple blocking in qPCR experiments.

    Science.gov (United States)

    Ganger, Michael T; Dietz, Geoffrey D; Ewing, Sarah J

    2017-12-01

    qPCR has established itself as the technique of choice for the quantification of gene expression. Procedures for conducting qPCR have received significant attention; however, more rigorous approaches to the statistical analysis of qPCR data are needed. Here we develop a mathematical model, termed the Common Base Method, for analysis of qPCR data based on threshold cycle values (C q ) and efficiencies of reactions (E). The Common Base Method keeps all calculations in the logscale as long as possible by working with log 10 (E) ∙ C q , which we call the efficiency-weighted C q value; subsequent statistical analyses are then applied in the logscale. We show how efficiency-weighted C q values may be analyzed using a simple paired or unpaired experimental design and develop blocking methods to help reduce unexplained variation. The Common Base Method has several advantages. It allows for the incorporation of well-specific efficiencies and multiple reference genes. The method does not necessitate the pairing of samples that must be performed using traditional analysis methods in order to calculate relative expression ratios. Our method is also simple enough to be implemented in any spreadsheet or statistical software without additional scripts or proprietary components.

  9. Characteristics of Pediatric Performance on a Test Battery Commonly Used in the Diagnosis of Central Auditory Processing Disorder.

    Science.gov (United States)

    Weihing, Jeffrey; Guenette, Linda; Chermak, Gail; Brown, Mallory; Ceruti, Julianne; Fitzgerald, Krista; Geissler, Kristin; Gonzalez, Jennifer; Brenneman, Lauren; Musiek, Frank

    2015-01-01

    Although central auditory processing disorder (CAPD) test battery performance has been examined in adults with neurologic lesions of the central auditory nervous system (CANS), similar data on children being referred for CAPD evaluations are sparse. This study characterizes CAPD test battery performance in children using tests commonly administered to diagnose the disorder. Specifically, this study describes failure rates for various test combinations, relationships between CAPD tests used in the battery, and the influence of cognitive function on CAPD test performance and CAPD diagnosis. A comparison is also made between the performance of children with CAPD and data from patients with neurologic lesions of the CANS. A retrospective study. Fifty-six pediatric patients were referred for CAPD testing. Participants were administered four CAPD tests, including frequency patterns (FP), low-pass filtered speech (LPFS), dichotic digits (DD), and competing sentences (CS). In addition, they were given the Wechsler Intelligence Scale for Children (WISC). Descriptive analyses examined the failure rates of various test combinations, as well as how often children with CAPD failed certain combinations when compared with adults with CANS lesions. A principal components analysis was performed to examine interrelationships between tests. Correlations and regressions were conducted to determine the relationship between CAPD test performance and the WISC. Results showed that the FP and LPFS tests were most commonly failed by children with CAPD. Two-test combinations that included one or both of these two tests and excluded DD tended to be failed more often. Including the DD and CS test in a battery benefited specificity. Tests thought to measure interhemispheric transfer tended to be correlated. Compared with adult patients with neurologic lesions, children with CAPD tended to fail LPFS more frequently and DD less frequently. Both groups failed FP with relatively equal frequency

  10. Methods and characteristics of assembly language software testing

    International Nuclear Information System (INIS)

    Wang Lingfang

    2001-01-01

    Single chip micro-controllers are widely implemented to the controlling and testing products in industrial controlling and national defence embedded controlling systems. The invalidation of the source programs could lead to the unreliability of the whole systems, even to cause fatal results. Therefore, software testing is the necessary measures to reduce the mistakes and to improve the quality of the software. In the paper, the development of the software testing is presented. The distinctions between the assembly language testing and those of the high level languages is introduced. And the essential flow and methods of software testing are discussed in detail

  11. Study on operation I and C DCS test method of EPR project

    International Nuclear Information System (INIS)

    Meng Ying; Lv Zhihong; Huang Xinnian; Fan Haiying; Li Zhuojia; Xiao Shushu

    2014-01-01

    Through summarization and optimization of the method for operation I and C DCS test of the European pressurized reactor project, the conclusions play a guiding role on the operation I and C DCS test of the domestic advanced nuclear power plant. The study of the method focuses on the test platform, the test process and the optimization of method of operation I and C DCS test with the practical experience. The reasonable and reliable test method for operation I and C DCS test of the European pressurized reactor project is worthy of the reference and the development in the project of the domestic advanced nuclear power plant. (authors)

  12. 40 CFR 63.1046 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1046 Test methods... vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... test, the cover and closure devices shall be secured in the closed position. (3) The detection...

  13. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1990-01-01

    Methods are proposed for the construction of weakly parallel tests, that is, tests with the same test information function. A mathematical programing model for constructing tests with a prespecified test information function and a heuristic for assigning items to tests such that their information

  14. No sulfates, no parabens, and the "no-poo" method: a new patient perspective on common shampoo ingredients.

    Science.gov (United States)

    Cline, Abigail; Uwakwe, Laura N; McMichael, Amy J

    2018-01-01

    The ingredients in shampoos and other cosmetic products have become scrutinized by the general public and the Internet has contributed to misinformation about certain shampoos. Dermatologists must be prepared to acknowledge the concerns that their patients have about common shampoo ingredients to dispel the myths that may misinform patient decision-making. This article reviews the controversy surrounding the use of sulfates and parabens in shampoos, as well as commonly used shampoo alternatives, often called the "no-poo" method.

  15. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  16. Advantages and applicability of commonly used homogenisation methods for climate data

    Science.gov (United States)

    Ribeiro, Sara; Caineta, Júlio; Henriques, Roberto; Soares, Amílcar; Costa, Ana Cristina

    2014-05-01

    Homogenisation of climate data is a very relevant subject since these data are required as an input in a wide range of studies, such as atmospheric modelling, weather forecasting, climate change monitoring, or hydrological and environmental projects. Often, climate data series include non-natural irregularities which have to be detected and removed prior to their use, otherwise it would generate biased and erroneous results. Relocation of weather stations or changes in the measuring instruments are amongst the most relevant causes for these inhomogeneities. Depending on the climate variable, its temporal resolution and spatial continuity, homogenisation methods can be more or less effective. For example, due to its natural variability, precipitation is identified as a very challenging variable to be homogenised. During the last two decades, numerous methods have been proposed to homogenise climate data. In order to compare, evaluate and develop those methods, the European project COST Action ES0601, Advances in homogenisation methods of climate series: an integrated approach (HOME), was released in 2008. Existing homogenisation methods were improved based on the benchmark exercise issued by this project. A recent approach based on Direct Sequential Simulation (DSS), not yet evaluated by the benchmark exercise, is also presented as an innovative methodology for homogenising climate data series. DSS already proved to be a successful geostatistical method in environmental and hydrological studies, and it provides promising results for the homogenisation of climate data. Since DSS is a geostatistical stochastic approach, it accounts for the joint spatial and temporal dependence between observations, as well as the relative importance of stations both in terms of distance and correlation. This work presents a chronological review of the most commonly used homogenisation methods for climate data and available software packages. A short description and classification is

  17. Factors that encourage females to pursue physical science careers: Testing five common hypotheses

    Science.gov (United States)

    Hazari, Zahra; Potvin, Geoff; Lock, Robynne M.; Lung, Florin; Sadler, Philip M.; Sonnert, Gerhard

    2012-03-01

    There are many hypotheses regarding factors that may encourage female students to pursue careers in the physical sciences. Using Propensity Score Matching (PSM) on national data (n=7505) drawn from the Persistence Research in Science and Engineering (PRiSE) project, we test five commonly held beliefs including having a single-sex physics class, having a female physics teacher, having female scientist guest speakers in physics class, discussing the work of women scientists in physics class, and discussing the under-representation of women in physics class. The effect of these experiences is compared for female students who are matched on several factors, including parental education, prior science/math interests, and academic background, thereby controlling for the effect of many confounding variables.

  18. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  19. Further comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Kulacsy, K. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1997-05-23

    The Bayesian method for belief updating proposed in Racz (1996) is examined. The interpretation of the belief function introduced therein is found, and the method is compared to the classical binary Sequential Probability Ratio Testing method (SPRT). (author).

  20. Test cases for interface tracking methods: methodology and current status

    International Nuclear Information System (INIS)

    Lebaigue, O.; Jamet, D.; Lemonnier, E.

    2004-01-01

    Full text of publication follows:In the past decade, a large number of new methods have been developed to deal with interfaces in the numerical simulation of two-phase flows. We have collected a set of 36 test cases, which can be seen as a tool to help engineers and researchers selecting the most appropriate method(s) for their specific fields of application. This set can be use: - To perform an initial evaluation of the capabilities of available methods with regard to the specificity of the final application and the most important features to be recovered from the simulation. - To measure the maximum mesh size to be used for a given physical problem in order to obtain an accurate enough solution. - To assess and quantify the performances of a selected method equipped with its set of physical models. The computation of a well-documented test case allows estimating the error due to the numerical technique by comparison with reference solutions. This process is compulsory to gain confidence and credibility on the prediction capabilities of a numerical method and its physical models. - To broaden the capabilities of a given numerical technique. The test cases may be used to identify the need for improvement of the overall numerical scheme or to determine the physical part of the model, which is responsible for the observed limitations. Each test case falls within one of the following categories: - Analytical solutions of well-known sets of equations corresponding to simple geometrical situations. - Reference numerical solutions of moderately complex problems, produced by accurate methods (e.g., boundary Fitted coordinate method) on refined meshes. - Separate effects analytical experiments. The presentation will suggest how to use the test cases for assessing the physical models and the numerical methods. The expected fallout of using test cases is indeed on the one hand to identify the merits of existing methods and on the other hand to orient further research towards

  1. Improvements in in-situ filter test methods using a total light-scattering detector

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1986-01-01

    This paper presents research aimed at providing useful data on a commonly used technique; a DOP (di-2-ethylhexyl phthalate) aerosol and a total light-scattering photometer. Methods of increasing the sensitivity of this technique are described. Alternative methods of in-situ filter testing are also considered. The sensitivity of a typical, modern, total light-scattering photometer, as a function of particle diameter, has a broad maximum in mass terms between 0.1 and 0.4 um. At its maximum usable sensitivity the instrument can detect approx. 1 particle/cm 3 . This response can be explained by light scattering theory and particle loss in the instrument inlet. The mass median diameter of the aerosols produced by various DOP generators varies from 0.2 to 1.0μm. Experiments with good quality HEPA filters indicate a maximum penetration for particles of 0.15 - 0.2μm. Details of the studies are given and the consequences discussed. It is shown that filter penetration of -3 % can be measured in-situ with existing equipment. Methods of extending the sensitivity to measure a penetration of approx.10 -5 % are described. (author)

  2. Test methods for protective footwear against AP mine blast

    NARCIS (Netherlands)

    Cronin, D.S.; Williams, K.; Bass, C.R.; Magnan, P.; Dosquet, F.; Bergeron, D.M.; Bree, J.L.M.J. van

    2003-01-01

    The testing and development of protective footwear for anti-personnel landmine blast threats is of great importance to civilian and military deminers, and peacekeepers. This study will review the wide range of test methods that have been developed by NATO countries to test footwear against the

  3. Standardization of waste acceptance test methods by the Materials Characterization Center

    International Nuclear Information System (INIS)

    Slate, S.C.

    1985-01-01

    This paper describes the role of standardized test methods in demonstrating the acceptability of high-level waste (HLW) forms for disposal. Key waste acceptance tests are standardized by the Materials Characterization Center (MCC), which the US Department of Energy (DOE) has established as the central agency in the United States for the standardization of test methods for nuclear waste materials. This paper describes the basic three-step process that is used to show that waste is acceptable for disposal and discusses how standardized tests are used in this process. Several of the key test methods and their areas of application are described. Finally, future plans are discussed for using standardized tests to show waste acceptance. 9 refs., 1 tab

  4. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  5. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  6. Statistical evidence for common ancestry: Application to primates.

    Science.gov (United States)

    Baum, David A; Ané, Cécile; Larget, Bret; Solís-Lemus, Claudia; Ho, Lam Si Tung; Boone, Peggy; Drummond, Chloe P; Bontrager, Martin; Hunter, Steven J; Saucier, William

    2016-06-01

    Since Darwin, biologists have come to recognize that the theory of descent from common ancestry (CA) is very well supported by diverse lines of evidence. However, while the qualitative evidence is overwhelming, we also need formal methods for quantifying the evidential support for CA over the alternative hypothesis of separate ancestry (SA). In this article, we explore a diversity of statistical methods using data from the primates. We focus on two alternatives to CA, species SA (the separate origin of each named species) and family SA (the separate origin of each family). We implemented statistical tests based on morphological, molecular, and biogeographic data and developed two new methods: one that tests for phylogenetic autocorrelation while correcting for variation due to confounding ecological traits and a method for examining whether fossil taxa have fewer derived differences than living taxa. We overwhelmingly rejected both species and family SA with infinitesimal P values. We compare these results with those from two companion papers, which also found tremendously strong support for the CA of all primates, and discuss future directions and general philosophical issues that pertain to statistical testing of historical hypotheses such as CA. © 2016 The Author(s). Evolution © 2016 The Society for the Study of Evolution.

  7. A method for automatically constructing the initial contour of the common carotid artery

    Directory of Open Access Journals (Sweden)

    Yara Omran

    2013-10-01

    Full Text Available In this article we propose a novel method to automatically set the initial contour that is used by the Active contours algorithm.The proposed method exploits the accumulative intensity profiles to locate the points on the arterial wall. The intensity profiles of sections that intersect the artery show distinguishable characterstics that make it possible to recognize them from the profiles of sections that do not intersect the artery walls. The proposed method is applied on ultrasound images of the transverse section of the common carotid artery, but it can be extended to be used on the images of the longitudinal section. The intensity profiles are classified using Support vector machine algorithm, and the results of different kernels are compared. The extracted features used for the classification are basically statistical features of the intensity profiles. The echogenicity of the arterial lumen, and gives the profiles that intersect the artery a special shape that helps recognizing these profiles from other general profiles.The outlining of the arterial walls may seem a classic task in image processing. However, most of the methods used to outline the artery start from a manual, or semi-automatic, initial contour.The proposed method is highly appreciated in automating the entire process of automatic artery detection and segmentation.

  8. Institutional investors' involuntary trading behaviors,commonality in liquidity change and stock price fragility

    Institute of Scientific and Technical Information of China (English)

    Guojin Chen; Aihuan Xu; Xiangqin Zhao

    2013-01-01

    Purpose-The aim of this paper is to empirically analyze the source of commonality in liquidity change in China's stock market.Design/methodology/approach-This paper used two-step test method in Coughenour and Saad and empirically tested the relationship between institutional investors' involuntary trading behaviors and commonality in liquidity change in China's stock market.Findings-The results showed that to take the open-end fund as a representative of institutional investors,their involuntary trading behaviors were an important source of commonality in liquidity change in China's stock market.Originality/value-For a long time,the domestic researchers have ignored the study about the source of commonality in liquidity change in China's stock market.But,this study's conclusion expanded the explanation about the source of commonality in liquidity change in China's stock market from a new point of view that the demand-side explanation.Because there is no market-maker trading behaviors in China's stock market,the paper cannot explain the source of commonality in liquidity change in China's stock market from the point of view of the supply-side explanation.

  9. Multiple HEPA filter test methods, January--December 1976

    International Nuclear Information System (INIS)

    Schuster, B.; Kyle, T.; Osetek, D.

    1977-06-01

    The testing of tandem high-efficiency particulate air (HEPA) filter systems is of prime importance for the measurement of accurate overall system protection factors. A procedure, based on the use of an intra-cavity laser particle spectrometer, has been developed for measuring protection factors in the 10 8 range. A laboratory scale model of a filter system was constructed and initially tested to determine individual HEPA filter characteristics with regard to size and state (liquid or solid) of several test aerosols. Based on these laboratory measurements, in-situ testing has been successfully conducted on a number of single and tandem filter installations within the Los Alamos Scientific Laboratory as well as on extraordinary large single systems at Rocky Flats. For the purpose of recovery and for simplified solid waste disposal, or prefiltering purposes, two versions of an inhomogeneous electric field air cleaner have been devised and are undergoing testing. Initial experience with one of the systems, which relies on an electrostatic spraying phenomenon, indicates performance efficiency of greater than 99.9% for flow velocities commonly used in air cleaning systems. Among the effluents associated with nuclear fuel reprocessing is 129 I. An intra-cavity laser detection system is under development which shows promise of being able to detect mixing ratios of one part in 10 7 , I 2 in air

  10. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  11. Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method

    Energy Technology Data Exchange (ETDEWEB)

    Diprete, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-28

    The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested a method using commercial sorbents containing Aliquat® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137Cs removal step. The method was initially tested on SRS tank waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.

  12. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  13. Standard test methods for analysis of sintered gadolinium oxide-uranium dioxide pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover procedures for the analysis of sintered gadolinium oxide-uranium dioxide pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Section Carbon (Total) by Direct CombustionThermal Conductivity Method C1408 Test Method for Carbon (Total) in Uranium Oxide Powders and Pellets By Direct Combustion-Infrared Detection Method Chlorine and Fluorine by Pyrohydrolysis Ion-Selective Electrode Method C1502 Test Method for Determination of Total Chlorine and Fluorine in Uranium Dioxide and Gadolinium Oxide Gadolinia Content by Energy-Dispersive X-Ray Spectrometry C1456 Test Method for Determination of Uranium or Gadolinium, or Both, in Gadolinium Oxide-Uranium Oxide Pellets or by X-Ray Fluorescence (XRF) Hydrogen by Inert Gas Fusion C1457 Test Method for Determination of Total Hydrogen Content of Uranium Oxide Powders and Pellets by Carrier Gas Extraction Isotopic Uranium Composition by Multiple-Filament Surface-Ioni...

  14. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  15. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1992-01-01

    Several methods are proposed for the construction of weakly parallel tests [i.e., tests with the same test information function (TIF)]. A mathematical programming model that constructs tests containing a prespecified TIF and a heuristic that assigns items to tests with information functions that are

  16. CNOSSOS-EU: Development of a common environmental noise assessment method in the European Union

    International Nuclear Information System (INIS)

    Aspuru Soloaga, I.; Segues Echazarreta Segues, F.

    2011-01-01

    This article presents the main aspects of the work undertaken in the development of the common european method of environmental noise assessment CNOSSOS-EU. It summarizes the design, structure and content, and the methodological basis on which it is based. Taking into account the experience gained in the first round of strategic noise mapping, some conclusions are settled about its applications for the third round, and tits implications for the Spanish case. (Author) 9 refs.

  17. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  19. A Fuzzy Logic Based Method for Analysing Test Results

    Directory of Open Access Journals (Sweden)

    Le Xuan Vinh

    2017-11-01

    Full Text Available Network operators must perform many tasks to ensure smooth operation of the network, such as planning, monitoring, etc. Among those tasks, regular testing of network performance, network errors and troubleshooting is very important. Meaningful test results will allow the operators to evaluate network performanceof any shortcomings and to better plan for network upgrade. Due to the diverse and mainly unquantifiable nature of network testing results, there is a needs to develop a method for systematically and rigorously analysing these results. In this paper, we present STAM (System Test-result Analysis Method which employs a bottom-up hierarchical processing approach using Fuzzy logic. STAM is capable of combining all test results into a quantitative description of the network performance in terms of network stability, the significance of various network erros, performance of each function blocks within the network. The validity of this method has been successfully demonstrated in assisting the testing of a VoIP system at the Research Instiute of Post and Telecoms in Vietnam. The paper is organized as follows. The first section gives an overview of fuzzy logic theory the concepts of which will be used in the development of STAM. The next section describes STAM. The last section, demonstrating STAM’s capability, presents a success story in which STAM is successfully applied.

  20. A basis of common approach to the development of universal steganalysis methods for digital images

    Directory of Open Access Journals (Sweden)

    Alla А. Kobozeva

    2014-12-01

    Full Text Available In this paper a new common approach to the organization of steganalysis in digital images is developed. New features of formal parameters defining the image are identified, theoretically grounded and practically tested. For the first time characteristics of mutual disposition of the left and right singular vectors corresponding to the largest singular value of the matrix (block of matrix of an image and the vector composed of the singular values obtained as a result of normal singular decomposition of the matrix (block matrix are obtained. It is shown that for the majority of the blocks of the original image (regardless of the storage format — lossy, lossless the angle between the left (right singular vector and the vector composed of singular numbers is determined by the angle between the n-optimal vector and the standard space basis of the corresponding dimension. It is shown that the discovered feature is violated for the mentioned formal parameters in the disturbed image. This is an indicator of integrity violation, particularly steganotransformation, and it can be used to develop new universal steganalysis methods and algorithms. Their efficiency does not depend on the specifics of steganoalgorithm used for insertion of additional information.

  1. Abrasive Wear Resistance of the Iron- and WC-based Hardfaced Coatings Evaluated with Scratch Test Method

    Directory of Open Access Journals (Sweden)

    A. Vencl

    2013-06-01

    Full Text Available Abrasive wear is one of the most common types of wear, which makesabrasive wear resistance very important in many industries. Thehard facing is considered as useful and economical way to improve theperformance of components submitted to severe abrasive wear conditions, with wide range of applicable filler materials. The abrasive wear resistance of the three different hardfaced coatings (two iron‐based and one WC‐based, which were intended to be used for reparation of the impact plates of the ventilation mill, was investigated and compared. Abrasive wear tests were carried‐out by using the scratch tester under the dry conditions. Three normal loads of 10, 50 and 100 N and the constant sliding speed of 4 mm/s were used. Scratch test was chosen as a relatively easy and quick test method. Wear mechanism analysis showed significant influence of the hardfaced coatings structure, which, along with hardness, has determined coatings abrasive wear resistance.

  2. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Science.gov (United States)

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  3. An accelerated test method for efflorescence in clay bricks

    International Nuclear Information System (INIS)

    Beggan, John Edward

    1998-01-01

    An investigation into the creation of accelerated efflorescence in clay bricks was undertaken with a view to creating a viable test procedure for determining efflorescence potential. The testing programme incorporated ambient conditions similar to those which promote efflorescence growth in bricks in use. Theoretical investigations into the physical mechanism underlying the creation of efflorescence directed the attempts to accelerate the process. It was found that calcium sulphate efflorescence could not be sufficiently accelerated such that a useful efflorescence test procedure could be proposed. The inability to produce accelerated efflorescence in brick samples was attributed to limitations associated with time dependent salt diffusion in the efflorescence mechanism. The preliminary testing that was undertaken into the creation of efflorescence prompted the use of acid assisted methods to accelerate efflorescence. The acid assisted method that was adopted to provide a possible indication of efflorescence potential relies upon the transformation of low solubility calcium to a more soluble form. The movement of the transformed salt is then induced by cyclic temperature exposure at temperatures similar to those experienced in Spring. The appearance of the transformed calcium salt on the surface of the brick specimen provides an indication of the efflorescence potential. Brick piers constructed on an exposed site and monitored over a 12 month period provided information on the validity of the acid assisted test method. The efflorescence observed on the piers correlated well with that predicted by the acid assisted test, suggesting that the new test has the potential to accurately predict the efflorescence potential of clay bricks Relationships between other properties such as air permeability, sorptivity and tensile strength were investigated such that an alternative method of predicting efflorescence could be achieved. It was found that (within the bounds of the

  4. Intercomparison of leach-testing methods and the effects of waste-form composition on test type and duration

    International Nuclear Information System (INIS)

    Harvey, K.B.; Jensen, C.D.

    1982-01-01

    Several leach-testing methods were evaluated for their relevance as scoping tests appropriate to proposed Canadian conditions for the disposal of high-level nuclear waste, and a static, terminated leach test was chosen. For a particular glass composition, methods in which the leachant was replenished gave apparent leach rates up to ten times less than did the static test. Under static leaching conditions, the leach rate of a number of sodium borosilicate glasses was observed to first rise and then fall with leaching time. This behavior is explained in terms of a pH change in the leachant, which is itself a function of the glass composition. The implications of these observations on glass compositions and on leach-testing methods that are relevant to the needs of final disposal are briefly discussed

  5. TTC- Based Test as an Efficient Method to Determine Antibiofilm Activity of Silver Nanoparticles

    Directory of Open Access Journals (Sweden)

    Chojniak Joanna

    2017-01-01

    Full Text Available Among metal nanoparticles, silver nanoparticles are a widely used in various life sectors such as in biomedical applications, air and water purification, food production, cosmetics, garments and in various household products. There are several methods for production of silver nanoparticles. Generally, silver nanoparticles can be prepared by chemical methods such as chemical reduction and electrochemical techniques, physical methods, and biological methods such as the use of microorganisms. The biological route of synthesis provides a great diversity in choice for its raw materials such as bacteria, algae, fungi and plants. The aim of the study was to evaluate the tetrazolium/formazan test as a method to determine antibiofilm activity of biological synthetized silver nanoparticles. In this study Bacillus subtilis grown on brewery effluent and produced biosurfactant was used for silver nanoparticles (Ag-NPs synthesis. The culture supernatants were used in synthesis of Ag-NPs. The formation of nanoparticles accompanied by colour changes of the used reaction system was confirmed by UV-vis spectroscopy. The bacteria isolated from the biofilm of water supply system were used in the evaluation of the antibiofilm activity of biologically synthetized Ag-NPs. To compare the results the commonly used crystal violet assay (CV for biofilm analysis was applied.

  6. Estimation of common cause failure parameters with periodic tests

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Anne [Institut Charles Delaunay - Universite de technologie de Troyes - FRE CNRS 2848, 12, rue Marie Curie - BP 2060 -10010 Troyes cedex (France)], E-mail: anne.barros@utt.fr; Grall, Antoine [Institut Charles Delaunay - Universite de technologie de Troyes - FRE CNRS 2848, 12, rue Marie Curie - BP 2060 -10010 Troyes cedex (France); Vasseur, Dominique [Electricite de France, EDF R and D - Industrial Risk Management Department 1, av. du General de Gaulle- 92141 Clamart (France)

    2009-04-15

    In the specific case of safety systems, CCF parameters estimators for standby components depend on the periodic test schemes. Classically, the testing schemes are either staggered (alternation of tests on redundant components) or non-staggered (all components are tested at the same time). In reality, periodic tests schemes performed on safety components are more complex and combine staggered tests, when the plant is in operation, to non-staggered tests during maintenance and refueling outage periods of the installation. Moreover, the CCF parameters estimators described in the US literature are derived in a consistent way with US Technical Specifications constraints that do not apply on the French Nuclear Power Plants for staggered tests on standby components. Given these issues, the evaluation of CCF parameters from the operating feedback data available within EDF implies the development of methodologies that integrate the testing schemes specificities. This paper aims to formally propose a solution for the estimation of CCF parameters given two distinct difficulties respectively related to a mixed testing scheme and to the consistency with EDF's specific practices inducing systematic non-simultaneity of the observed failures in a staggered testing scheme.

  7. 40 CFR 63.750 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... method in production on actual production parts or assemblies for a period of time sufficient to coat an... a laboratory or pilot production area, using parts and coatings representative of the process(es) where the alternative method is to be used. The laboratory test will use the same part configuration(s...

  8. 40 CFR 63.1257 - Test methods and compliance procedures.

    Science.gov (United States)

    2010-07-01

    ... chemical engineering principles, measurable process parameters, or physical or chemical laws or properties... flow rate and concentration; temperature; and the reaction kinetics of the constituents with the... Method 8260 or 8270 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA...

  9. An analytic data analysis method for oscillatory slug tests.

    Science.gov (United States)

    Chen, Chia-Shyun

    2006-01-01

    An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.

  10. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  11. 40 CFR 63.425 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... maximum allowable 5-minute pressure increase is 130 mm H2 O (5 in. H2 O). (f) Leak detection test. The leak detection test shall be performed using Method 21, appendix A, 40 CFR part 60, except omit section... between each leak detection. The duration of the purge shall be in excess of two instrument response times...

  12. Pythium root rot of common bean: biology and control methods. A review

    Directory of Open Access Journals (Sweden)

    Baudoin, JP.

    2012-01-01

    Full Text Available Pythium root rot constitutes a highly damaging constraint on the common bean, Phaseolus vulgaris L., grown in several areas of Eastern and Central Africa. Here, this food legume is cultivated intensively under poor conditions of crop rotation due to the exiguity of the land in the region. Yield losses of up to 70% in traditional local bean cultivars have been reported in Kenya and Rwanda. In this study, a detailed analysis of the biology and diversity of the Pythium genus was carried out in order to understand the mechanisms leading to the development of the disease. Various control methods for reducing the damage provoked by this disease were analyzed.

  13. TESTING METHODS FOR MECHANICALLY IMPROVED SOILS: RELIABILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Ana Petkovšek

    2017-10-01

    Full Text Available A possibility of in-situ mechanical improvement for reducing the liquefaction potential of silty sands was investigated by using three different techniques: Vibratory Roller Compaction, Rapid Impact Compaction (RIC and Soil Mixing. Material properties at all test sites were investigated before and after improvement with the laboratory and the in situ tests (CPT, SDMT, DPSH B, static and dynamic load plate test, geohydraulic tests. Correlation between the results obtained by different test methods gave inconclusive answers.

  14. Facts about the Common Cold

    Science.gov (United States)

    ... different viruses. Rhinovirus is the most common cause, accounting for 10 to 40 percent of colds. Other common cold viruses include coronavirus and ... RSS | Terms Of Use | Privacy | Sitemap Our Family Of Sites ... Introduction Risk Factors Screening Symptoms Tumor Testing Summary '; var ...

  15. Using common mycorrhizal networks for controlled inoculation of Quercus spp. with Tuber melanosporum: the nurse plant method.

    Science.gov (United States)

    Pereira, Guillermo; Palfner, Götz; Chávez, Daniel; Suz, Laura M; Machuca, Angela; Honrubia, Mario

    2013-07-01

    The high cost and restricted availability of black truffle spore inoculum for controlled mycorrhiza formation of host trees produced for truffle orchards worldwide encourage the search for more efficient and sustainable inoculation methods that can be applied globally. In this study, we evaluated the potential of the nurse plant method for the controlled inoculation of Quercus cerris and Quercus robur with Tuber melanosporum by mycorrhizal networks in pot cultures. Pine bark compost, adjusted to pH 7.8 by liming, was used as substrate for all assays. Initially, Q. robur seedlings were inoculated with truffle spores and cultured for 12 months. After this period, the plants presenting 74 % mycorrhizal fine roots were transferred to larger containers. Nurse plants were used for two treatments of two different nursling species: five sterilized acorns or five 45-day-old, axenically grown Q. robur or Q. cerris seedlings, planted in containers around the nurse plant. After 6 months, colonized nursling plant root tips showed that mycorrhiza formation by T. melanosporum was higher than 45 % in the seedlings tested, with the most successful nursling combination being Q. cerris seedlings, reaching 81 % colonization. Bulk identification of T. melanosporum mycorrhizae was based on morphological and anatomical features and confirmed by sequencing of the internal transcribed spacer region of the ribosomal DNA of selected root tips. Our results show that the nurse plant method yields attractive rates of mycorrhiza formation by the Périgord black truffle and suggest that establishing and maintaining common mycorrhizal networks in pot cultures enables sustained use of the initial spore inoculum.

  16. Comparison of manual mycobacteria growth indicator tube and epsilometer test with agar proportion method for susceptibility testing of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    N Karabulut

    2014-01-01

    Full Text Available Background and Objectives: Antimycobacterial susceptibility tests take weeks, and delayed therapy can lead to spread of Mycobacterium tuberculosis. Therefore, rapid, accurate and cost-effective methods are required for proper therapy selection. In this study, the Mycobacteria growth indicator tube (MGIT and epsilometer test (Etest methods were compared to the agar proportion method for susceptibility testing of Mycobacterium tuberculosis. Materials and Methods: The susceptibility tests against isoniazid (INH, rifampin (RIF, streptomycin (STM and ethambutol (ETM of 51 M. tuberculosis complex isolates were analyzed by the MGIT, Etest and agar proportion methods. Results: The concordance between MGIT/Etest and agar proportion methods was 98% for INH and 100% for RIF, STM, ETM. There were not statistically significant differences in results of the susceptibility tests between MGIT/Etest and the reference agar proportion method. Conclusion: The results have shown that MGIT and Etest methods can be used instead of the agar proportion method, because these two methods are more rapid and easier than the agar proportion method.

  17. Comparative study of durability test methods for pellets and briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Temmerman, Michaeel; Rabier, Fabienne [Centre wallon de Recherches agronomiques (CRA-W), 146, chaussee de Namur, B-5030, Gembloux (Belgium); Jensen, Peter Daugbjerg [Forest and Landscape, The Royal Veterinary and Agricultural University, Rolighedsvej 23, DK-1958 Frederiksberg C (Denmark); Hartmann, Hans; Boehm, Thorsten [Technologie- und Foerderzentrum fuer Nachwachsende Rohstoffe-TFZ, Schulgasse 18, D-94315 Straubing (Germany)

    2006-11-15

    Different methods for the determination of the mechanical durability (DU) of pellets and briquettes were compared by international round robin tests including different laboratories. The DUs of five briquette and 26 pellet types were determined. For briquettes, different rotation numbers of a prototype tumbler and a calculated DU index are compared. For pellets testing, the study compares two standard methods, a tumbling device according to ASAE S 269.4, the Lignotester according to ONORM M 7135 and a second tumbling method with a prototype tumbler. For the tested methods, the repeatability, the reproducibility and the required minimum number of replications to achieve given accuracy levels were calculated. Additionally, this study evaluates the relation between DU and particle density. The results show for both pellets and briquettes, that the measured DU values and their variability are influenced by the applied method. Moreover, the variability of the results depend on the biofuel itself. For briquettes of DU above 90%, five replications lead to an accuracy of 2%, while 39 replications are needed to achieve an accuracy of 10%, when briquettes of DU below 90% are tested. For pellets, the tumbling device described by the ASAE standard allows to reach acceptable accuracy levels (1%) with a limited number of replications. Finally, for the tested pellets and briquettes no relation between DU and particle density was found. (author)

  18. A non-destructive selection method for faster growth at suboptimal temperature in common bean (Phaseolus vulgaris)

    NARCIS (Netherlands)

    Drijfhout, E.; Oeveren, J.C. van; Jansen, R.C.

    1991-01-01

    A non-destructive method has been developed to select common bean (Phaseolus vulgaris L.) plants whose growth is less effected at a suboptimal temperature. Shoot weight was determined at a suboptimal (14°C) and optimal temperature (20°C), 38 days after sowing and accessions identified with a

  19. Impact Strength of Natural Fibre Composites Measured by Different Test Methods: A Review

    Directory of Open Access Journals (Sweden)

    Navaranjan Namasivayam

    2017-01-01

    Full Text Available Different types of impact test methods have been used in recent years to measure the impact resistance of natural fibre composites (NFCs. After reviewing the literature, the impact resistance of flax, hemp, sisal, wood and jute fibre composites that were measured using different test methods have been compared and discussed. It has been learned that the test methods were selected for research interest, industry requirement or availability of test equipment. Each method had its own advantages and limitations. The result from a particular test could be compared but not with the result from other test methods. Most impact test methods were developed for testing ductile-brittle transition of metals. However, each NFC has a different morphology and cannot be comparable to metals in failure mode and energy absorption characteristic during an impact test. A post evaluation of morphology of an NFC sample after an impact test is important to characterise the material.

  20. Feasibility of supervised self-testing using an oral fluid-based HIV rapid testing method: a cross-sectional, mixed method study among pregnant women in rural India

    OpenAIRE

    Sarkar, Archana; Mburu, Gitau; Shivkumar, Poonam Varma; Sharma, Pankhuri; Campbell, Fiona; Behera, Jagannath; Dargan, Ritu; Mishra, Surendra Kumar; Mehra, Sunil

    2016-01-01

    Introduction: HIV self-testing can increase coverage of essential HIV services. This study aimed to establish the acceptability, concordance and feasibility of supervised HIV self-testing among pregnant women in rural India. Methods: A cross-sectional, mixed methods study was conducted among 202 consenting pregnant women in a rural Indian hospital between August 2014 and January 2015. Participants were provided with instructions on how to self-test using OraQuick® HIV antibody test, and subse...

  1. Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Tracers and Tracer Testing: Design, Implementation, Tracer Selection, and Interpretation Methods

    Energy Technology Data Exchange (ETDEWEB)

    G. Michael Shook; Shannon L.; Allan Wylie

    2004-01-01

    Conducting a successful tracer test requires adhering to a set of steps. The steps include identifying appropriate and achievable test goals, identifying tracers with the appropriate properties, and implementing the test as designed. When these steps are taken correctly, a host of tracer test analysis methods are available to the practitioner. This report discusses the individual steps required for a successful tracer test and presents methods for analysis. The report is an overview of tracer technology; the Suggested Reading section offers references to the specifics of test design and interpretation.

  3. Nondestructive testing method for a new generation of electronics

    Directory of Open Access Journals (Sweden)

    Azin Anton

    2018-01-01

    Full Text Available The implementation of the Smart City system needs reliable and smoothly operating electronic equipment. The study is aimed at developing a nondestructive testing method for electronic equipment and its components. This method can be used to identify critical design defects of printed circuit boards (PCB and to predict their service life, taking into account the nature of probable operating loads. The study uses an acoustic emission method to identify and localize critical design defects of printed circuit boards. Geometric dimensions of detected critical defects can be determined by the X-ray tomography method. Based on the results of the study, a method combining acoustic emission and X-ray tomography was developed for nondestructive testing of printed circuit boards. The stress-strain state of solder joints containing detected defects was analyzed. This paper gives an example of using the developed method for estimating the degree of damage to joints between PCB components and predicting the service life of the entire PCB.

  4. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  5. Test method research on weakening interface strength of steel - concrete under cyclic loading

    Science.gov (United States)

    Liu, Ming-wei; Zhang, Fang-hua; Su, Guang-quan

    2018-02-01

    The mechanical properties of steel - concrete interface under cyclic loading are the key factors affecting the rule of horizontal load transfer, the calculation of bearing capacity and cumulative horizontal deformation. Cyclic shear test is an effective method to study the strength reduction of steel - concrete interface. A test system composed of large repeated direct shear test instrument, hydraulic servo system, data acquisition system, test control software system and so on is independently designed, and a set of test method, including the specimen preparation, the instrument preparation, the loading method and so on, is put forward. By listing a set of test results, the validity of the test method is verified. The test system and the test method based on it provide a reference for the experimental study on mechanical properties of steel - concrete interface.

  6. Comparative study of heuristic evaluation and usability testing methods.

    Science.gov (United States)

    Thyvalikakath, Thankam Paul; Monaco, Valerie; Thambuganipalle, Himabindu; Schleyer, Titus

    2009-01-01

    Usability methods, such as heuristic evaluation, cognitive walk-throughs and user testing, are increasingly used to evaluate and improve the design of clinical software applications. There is still some uncertainty, however, as to how those methods can be used to support the development process and evaluation in the most meaningful manner. In this study, we compared the results of a heuristic evaluation with those of formal user tests in order to determine which usability problems were detected by both methods. We conducted heuristic evaluation and usability testing on four major commercial dental computer-based patient records (CPRs), which together cover 80% of the market for chairside computer systems among general dentists. Both methods yielded strong evidence that the dental CPRs have significant usability problems. An average of 50% of empirically-determined usability problems were identified by the preceding heuristic evaluation. Some statements of heuristic violations were specific enough to precisely identify the actual usability problem that study participants encountered. Other violations were less specific, but still manifested themselves in usability problems and poor task outcomes. In this study, heuristic evaluation identified a significant portion of problems found during usability testing. While we make no assumptions about the generalizability of the results to other domains and software systems, heuristic evaluation may, under certain circumstances, be a useful tool to determine design problems early in the development cycle.

  7. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2000-01-01

    Software test is the important stage in software process. The has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test class method based on interface object. In this method a set of basic test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  8. Evaluation of rapid radiometric method for drug susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Libonati, J.P.; Middlebrook, G.

    1981-01-01

    A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with 14 C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests results reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations

  9. Nondestructive testing of concrete structures

    International Nuclear Information System (INIS)

    Rufino, Randy R.; Relunia, Estrella

    1999-01-01

    Nondestructive testing of concrete is highly inhomogeneous which makes it cumbersome to setup experimental procedures and analyze experimental data. However, recent research and development activities have discovered the different methods of NDT, like the electromagnetic method, ultrasonic pulse velocity test, pulse echo/impact echo test, infrared thermography, radar or short pulse radar techniques, neutron and gamma radiometry, radiography, carbonation test and half-cell potential method available for NDT of concrete structures. NDT of concrete is emerging as a useful tool for quality control and assurance. This papers also describes the more common NDT methods discussed during the two-week course on 'Nondestructive Testing of Concrete Structures', held at the Malaysian Institute for Nuclear Technology Research (MINT) in Malaysia, which was jointly organized by MINT and the International Atomic Energy Agency (IAEA)

  10. Lessons learned in preparing method 29 filters for compliance testing audits.

    Science.gov (United States)

    Martz, R F; McCartney, J E; Bursey, J T; Riley, C E

    2000-01-01

    Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the

  11. Test report for cesium powder and pellets inner container decontamination method determination test

    International Nuclear Information System (INIS)

    Kelly, D.L.

    1998-01-01

    This report documents the decontamination method determination testing that was performed on three cesium powder and pellets inner container test specimens The test specimens were provided by B and W Hanford Company (BVMC). The tests were conducted by the Numatec Hanford Company (NHC), in the 305 Building. Photographic evidence was also provided by NHC. The Test Plan and Test Report were provided by Waste Management Federal Services, Inc., Northwest Operations. Witnesses to testing included a test engineer, a BC project engineer, and a BC Quality Assurance (QA) representative. The Test Plan was modified with the mutual decision of the test engineer, the BWHC project engineer, and the BVMC QA representative. The results of this decision were written in red (permanent type) ink on the official copy of the test procedure, Due to the extent of the changes, a summary of the test results are provided in Section 3.0 of this Test Report. In addition, a copy of the official copy field documentation obtained during testing is included in Appendix A. The original Test Plan (HNF-2945) will be revised to indicate that extensive changes were required in the field during testing, however, the test documentation will stand as is (i.e., it will not be retyped, text shaded, etc.) due to the inclusion of the test parameters and results into this Test Report

  12. Critical wall shear stress for the EHEDG test method

    DEFF Research Database (Denmark)

    Jensen, Bo Boye Busk; Friis, Alan

    2004-01-01

    In order to simulate the results of practical cleaning tests on closed processing equipment, based on wall shear stress predicted by computational fluid dynamics, a critical wall shear stress is required for that particular cleaning method. This work presents investigations that provide a critical...... wall shear stress of 3 Pa for the standardised EHEDG cleaning test method. The cleaning tests were performed on a test disc placed in a radial flowcell assay. Turbulent flow conditions were generated and the corresponding wall shear stresses were predicted from CFD simulations. Combining wall shear...... stress predictions from a simulation using the low Re k-epsilon and one using the two-layer model of Norris and Reynolds were found to produce reliable predictions compared to empirical solutions for the ideal flow case. The comparison of wall shear stress curves predicted for the real RFC...

  13. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  14. WE-E-201-01: Use and Abuse of Common Statistics in Radiological Physics

    Energy Technology Data Exchange (ETDEWEB)

    Labby, Z. [University of Wisconsin (United States)

    2015-06-15

    Physicists are often expected to have a solid grounding in experimental design and statistical analysis, sometimes filling in when biostatisticians or other experts are not available for consultation. Unfortunately, graduate education on these topics is seldom emphasized and few opportunities for continuing education exist. Clinical physicists incorporate new technology and methods into their practice based on published literature. A poor understanding of experimental design and analysis could Result in inappropriate use of new techniques. Clinical physicists also improve current practice through quality initiatives that require sound experimental design and analysis. Academic physicists with a poor understanding of design and analysis may produce ambiguous (or misleading) results. This can Result in unnecessary rewrites, publication rejection, and experimental redesign (wasting time, money, and effort). This symposium will provide a practical review of error and uncertainty, common study designs, and statistical tests. Instruction will primarily focus on practical implementation through examples and answer questions such as: where would you typically apply the test/design and where is the test/design typically misapplied (i.e., common pitfalls)? An analysis of error and uncertainty will also be explored using biological studies and associated modeling as a specific use case. Learning Objectives: Understand common experimental testing and clinical trial designs, what questions they can answer, and how to interpret the results Determine where specific statistical tests are appropriate and identify common pitfalls Understand the how uncertainty and error are addressed in biological testing and associated biological modeling.

  15. WE-E-201-01: Use and Abuse of Common Statistics in Radiological Physics

    International Nuclear Information System (INIS)

    Labby, Z.

    2015-01-01

    Physicists are often expected to have a solid grounding in experimental design and statistical analysis, sometimes filling in when biostatisticians or other experts are not available for consultation. Unfortunately, graduate education on these topics is seldom emphasized and few opportunities for continuing education exist. Clinical physicists incorporate new technology and methods into their practice based on published literature. A poor understanding of experimental design and analysis could Result in inappropriate use of new techniques. Clinical physicists also improve current practice through quality initiatives that require sound experimental design and analysis. Academic physicists with a poor understanding of design and analysis may produce ambiguous (or misleading) results. This can Result in unnecessary rewrites, publication rejection, and experimental redesign (wasting time, money, and effort). This symposium will provide a practical review of error and uncertainty, common study designs, and statistical tests. Instruction will primarily focus on practical implementation through examples and answer questions such as: where would you typically apply the test/design and where is the test/design typically misapplied (i.e., common pitfalls)? An analysis of error and uncertainty will also be explored using biological studies and associated modeling as a specific use case. Learning Objectives: Understand common experimental testing and clinical trial designs, what questions they can answer, and how to interpret the results Determine where specific statistical tests are appropriate and identify common pitfalls Understand the how uncertainty and error are addressed in biological testing and associated biological modeling

  16. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  17. 40 CFR 60.46 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... material balance over the steam generating system shall be used to confirm the rate. (d) The owner or...-Fired Steam Generators for Which Construction Is Commenced After August 17, 1971 § 60.46 Test methods... D2015, or D5865 (solid fuels), D240 (liquid fuels), or D1826 (gaseous fuels) (all of these methods are...

  18. IgE Sensitization Patterns to Commonly Consumed Foods Determined by Skin Prick Test in Korean Adults

    OpenAIRE

    Kim, Sung Ryeol; Park, Hye Jung; Park, Kyung Hee; Lee, Jae-Hyun; Park, Jung-Won

    2016-01-01

    Offending food allergens can vary with regional preferences in food consumption. In this study, we analysed sensitization rates to commonly consumed foods in Korean adults suspected of having food allergy. One hundred and thirty four subjects underwent a skin prick test (SPT) with 55 food allergens, of which 13 were made by our laboratory and the rest were commercially purchased. Of the 134 patients, 73 (54.5%) were sensitized to one or more food allergens. Sensitization to chrysalis was dete...

  19. The influence of technical testing methods on perceptions of constructions

    International Nuclear Information System (INIS)

    Oestberg, Gustaf

    2002-01-01

    In principle, methods of testing the reliability and safety of constructions are designed with the aim of representing critical conditions for their use. Because of variations within technical systems, including the one for which a certain test was once developed, the validity of the method also varies. The adoption of a standardized test for different applications had to be based on the assumption that the test deals adequately with a real situation. As a consequence of this acceptance of a trustworthy relationship between test and reality, an imprint of the former on the latter occurs. This effect may even cause the perception of a reality to be defined by the corresponding test. Examples of such an influence may be found in the field of materials testing. Related phenomena can be dealt with by reference to current concepts of cognitive science and psychology of the perception of images

  20. Study of test methods for radionuclide migration in aerated zone

    International Nuclear Information System (INIS)

    Li Shushen; Guo Zede; Wang Zhiming

    1993-01-01

    Aerated zone is an important natural barrier against transport of radionuclides released from disposal facilities of LLRW. This paper introduces study methods for radionuclide migration in aerated zone, including determination of water movement, laboratory simulation test, and field tracing test. For one purpose, results obtained with different methods are compared. These methods have been used in a five-year cooperative research project between CIRP and JAERI for an establishment of methodology for safety assessment on shallow land disposal of LLRW

  1. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2001-01-01

    Software test is the important stage in software process. There has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test-class method based on interface object. A set of basis test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  2. Standard test method for plane-strain (Chevron-Notch) fracture toughness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers the determination of plane-strain (chevron-notch) fracture toughnesses, KIv or KIvM, of metallic materials. Fracture toughness by this method is relative to a slowly advancing steady state crack initiated at a chevron-shaped notch, and propagating in a chevron-shaped ligament (Fig. 1). Some metallic materials, when tested by this method, exhibit a sporadic crack growth in which the crack front remains nearly stationary until a critical load is reached. The crack then becomes unstable and suddenly advances at high speed to the next arrest point. For these materials, this test method covers the determination of the plane-strain fracture toughness, KIvj or KIvM, relative to the crack at the points of instability. Note 1—One difference between this test method and Test Method E 399 (which measures KIc) is that Test Method E 399 centers attention on the start of crack extension from a fatigue precrack. This test method makes use of either a steady state slowly propagating crack, or a...

  3. The pattern and technique in the clinical evaluation of the adult hip: the common physical examination tests of hip specialists.

    Science.gov (United States)

    Martin, Hal D; Kelly, Bryan T; Leunig, Michael; Philippon, Marc J; Clohisy, John C; Martin, RobRoy L; Sekiya, Jon K; Pietrobon, Ricardo; Mohtadi, Nicholas G; Sampson, Thomas G; Safran, Marc R

    2010-02-01

    The purpose of this study was to systematically evaluate the technique and tests used in the physical examination of the adult hip performed by multiple clinicians who regularly treat patients with hip problems and identify common physical examination patterns. The subjects included 5 men and 6 women with a mean age (+/-SD) of 29.8 +/- 9.4 years. They underwent physical examination of the hip by 6 hip specialists with a strong interest in hip-related problems. All examiners were blind to patient radiographs and diagnoses. Patient examinations were video recorded and reviewed. It was determined that 18 tests were most frequently performed (>or=40%) by the examiners, 3 standing, 11 supine, 3 lateral, and 1 prone. Of the most frequently performed tests, 10 were performed more than 50% of the time. The tests performed in the supine position were as follows: flexion range of motion (ROM) (percentage of use, 98%), flexion internal rotation ROM (98%), flexion external rotation ROM (86%), passive supine rotation test (76%), flexion/adduction/internal rotation test (70%), straight leg raise against resistance test (61%), and flexion/abduction/external rotation test (52%). The tests performed in the standing position were the gait test (86%) and the single-leg stance phase test (77%). The 1 test in the prone position was the femoral anteversion test (58%). There are variations in the testing that hip specialists perform to examine and evaluate their patients, but there is enough commonality to form the basis to recommend a battery of physical examination maneuvers that should be considered for use in evaluating the hip. Patients presenting with groin, abdominal, back, and/or hip pain need to have a basic examination to ensure that the hip is not overlooked. A comprehensive physical examination of the hip will benefit the patient and the physician and serve as the foundation for future multicenter clinical studies. (c) 2010 Arthroscopy Association of North America. Published

  4. Common tester platform concept.

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, Michael James

    2008-05-01

    This report summarizes the results of a case study on the doctrine of a common tester platform, a concept of a standardized platform that can be applicable across the broad spectrum of testing requirements throughout the various stages of a weapons program, as well as across the various weapons programs. The common tester concept strives to define an affordable, next-generation design that will meet testing requirements with the flexibility to grow and expand; supporting the initial development stages of a weapons program through to the final production and surveillance stages. This report discusses a concept investing key leveraging technologies and operational concepts combined with prototype tester-development experiences and practical lessons learned gleaned from past weapons programs.

  5. Analysis of Power Transfer Efficiency of Standard Integrated Circuit Immunity Test Methods

    Directory of Open Access Journals (Sweden)

    Hai Au Huynh

    2015-01-01

    Full Text Available Direct power injection (DPI and bulk current injection (BCI methods are defined in IEC 62132-3 and IEC 62132-4 as the electromagnetic immunity test method of integrated circuits (IC. The forward power measured at the RF noise generator when the IC malfunctions is used as the measure of immunity level of the IC. However, the actual power that causes failure in ICs is different from forward power measured at the noise source. Power transfer efficiency is used as a measure of power loss of the noise injection path. In this paper, the power transfer efficiencies of DPI and BCI methods are derived and validated experimentally with immunity test setup of a clock divider IC. Power transfer efficiency varies significantly over the frequency range as a function of the test method used and the IC input impedance. For the frequency range of 15 kHz to 1 GHz, power transfer efficiency of the BCI test was constantly higher than that of the DPI test. In the DPI test, power transfer efficiency is particularly low in the lower test frequency range up to 10 MHz. When performing the IC immunity tests following the standards, these characteristics of the test methods need to be considered.

  6. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Usability Testing as a Method to Refine a Health Sciences Library Website.

    Science.gov (United States)

    Denton, Andrea H; Moody, David A; Bennett, Jason C

    2016-01-01

    User testing, a method of assessing website usability, can be a cost-effective and easily administered process to collect information about a website's effectiveness. A user experience (UX) team at an academic health sciences library has employed user testing for over three years to help refine the library's home page. Test methodology used in-person testers using the "think aloud" method to complete tasks on the home page. Review of test results revealed problem areas of the design and redesign; further testing was effective in refining the page. User testing has proved to be a valuable method to engage users and provide feedback to continually improve the library's home page.

  8. The former Semipalatinsk Test Site survey by field γ-spectrometry method

    International Nuclear Information System (INIS)

    Pakhomov, S.A.; Dubasov, Yu.V.; Biryukov, E.I.; Gavrilin, S.S.; Ilyin, L.I.

    2001-01-01

    Full text: Field γ-spectrometry method is the most productive method of getting an information on gamma-irradiating radionuclides contents in objects under survey. For many years the Radium Institute was the most active participant of works on radiation survey of the Semipalatinsk Test Site, field γ-spectrometry method including. In field γ-spectrometry method realization the existence of corresponding apparatus, and methodic software is supposed to be allowing to carry out both measurement, recording of γ-spectrometry energetic characteristics in field conditions and final treatment (using corresponding physical models) ensuring obtaining the information on radionuclides' contents. Different variants of such apparatus were developed and made at the Radium Institute. Under conditions of complex spectral structure and high intensity existence a portable variant of Ge(Li)-detector spectrometer fed by alkaline accumulators and allowing to record a spectrum at high load was elaborated. For walk γ-survey in common with the University two variants of portable spectrometers 'Skif-3' were elaborated: one of them with a standard scintillation detector on the base of Nal(Ti) crystal, having the size of 63x63 mm, and the other is an 'X-ray' detector of large dimension on the base of CsI crystal with a diameter of 165 mm, designated for soft gamma-irradiation registration, 241 Am including. During 8 hours of independent works 'Skif-3' is able to record into internal memory up to 100 spectra with an exposure up to 9999 s. At 10 min exposure in its sensitivity of 241 Am finding (10 Bq/kg) a spectrometer 'Skif-3' excels a portable spectrometer 'InSpector' (Canberra) working with the exposure of 1 hour. For automobile measurements a car spectrometer was elaborated fed. from car board supply and having four detectors based on NaI crystals with the dimensions 200x110 mm and total volume of about 121. For express treatment of a 'Skif-3' spectrometer scintillation spectra special

  9. In vitro antifungal susceptibility testing of Scopulariopsis brevicaulis strains using agar diffusion method.

    Science.gov (United States)

    Skóra, Magdalena; Macura, Anna B

    2011-01-01

    The genus Scopulariopsis is a common soil saprotroph and has been isolated from air, organic waste and also from plant, animal and human tissues. Scopulariopsis has mainly been associated in humans with superficial mycoses, but it has also been described as the cause of subcutaneous and invasive infections. The most common aetiological agent of infections in humans is Scopulariopsis brevicaulis. This species has been reported to be resistant in vitro to broad-spectrum antifungal agents available today. The aim of the study was to establish in vitro antifungal susceptibility of 35 S. brevicaulis strains against amphotericin B (AMB), flucytosine (FC), caspofungin (CAS), terbinafine (TER), ciclopirox (CIC), voriconazole (VOR), clotrimazole (CTR), miconazole (MCZ), econazole (ECO), ketoconazole (KET), itraconazole (ITR), and fluconazole (FLU). Antifungal susceptibility tests were evaluated by an agar diffusion method (Neo-Sensitabs, Rosco, Denmark). AMB, FC, CAS, ITR and FLU showed no antifungal activity against S. brevicaulis. TER, CIC, CTR, KET, VOR, ECO, and MCZ revealed inhibitory activity for S. brevicaulis, but it varied for each of the drugs. The best antifungal effect was observed for TER and CIC. All isolates had large inhibition zones for TER and CIC. CTR was also inhibitory for all tested S. brevicaulis isolates, but the diameters of inhibition zones were smaller than for TER and CIC. Nearly 89% isolates showed inhibition zones for KET and the mean diameter of the inhibition zone was comparable to CTR. The least antifungal activity exhibited VQR, ECO and MCZ. Because of the multiresistance of S. brevicaulis, infections due to this species may not respond to particular antifungal treatment and other therapeutic approaches should be considered, e.g., combined therapy and/or surgery.

  10. Study on the system-level test method of digital metering in smart substation

    Science.gov (United States)

    Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing

    2017-03-01

    Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.

  11. Testing of VVER reactor pressure vessels by TOFD method

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2002-01-01

    The Time of Flight Diffraction Method (TOFD) - one of the new testing methods capable to obtain the real dimensions of flaws - is presented in the paper.The laboratory experiments on samples with artificial flaws and samples with artificially prepared cracks confirmed the high accuracy of flaw through wall extent sizing by TOFD. This accuracy was confirmed by qualification of methods and systems used by Skoda JS for the in-service inspections of WWER 440 vessel circumferential weld. The qualification also confirmed the ability of TOFD to detect reliably flaws, which can are not reliably detected by standard pulse echo testing. Based on the result of experiments and qualification, the TOFD method shall be used routinely by Skoda JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level

  12. Common Fluorescence In Situ Hybridization Applications in Cytology.

    Science.gov (United States)

    Savic, Spasenija; Bubendorf, Lukas

    2016-12-01

    - Fluorescence in situ hybridization (FISH) is a well-established method for detection of genomic aberrations in diagnostic, prognostic, and predictive marker testing. - To review common applications of FISH in cytology. - The published literature was reviewed. - Cytology is particularly well suited for all kinds of FISH applications, which is highlighted in respiratory tract cytology with an increasing demand for predictive FISH testing in lung cancer. Fluorescence in situ hybridization is the gold standard for detection of predictive anaplastic lymphoma kinase gene (ALK) rearrangements, and the same evaluation criteria as in histology apply to cytology. Several other gene rearrangements, including ROS proto-oncogene 1 receptor tyrosine kinase (ROS1), are becoming clinically important and share the same underlining cytogenetic mechanisms with ALK. MET amplification is one of the most common mechanisms of acquired resistance to epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors and can be targeted by crizotinib. As genomic aberrations are a hallmark of malignant cells, FISH is a valuable objective ancillary diagnostic tool. In urinary tract cytology, atypical urothelial cells equivocal for malignancy are a common diagnostic dilemma and multitarget FISH can help clarify such cells. Diagnosis of malignant mesothelioma remains one of the most challenging fields in effusion cytology, and ancillary FISH is useful in establishing the diagnosis. Fluorescence in situ hybridization is a morphology-based technique, and the prerequisite for reliable FISH results is a targeted evaluation of the cells in question (eg, cancer or atypical cells). Cytopathologists and cytotechnicians should therefore be involved in molecular testing in order to select the best material and to provide their morphologic expertise.

  13. Nondestructive testing methods in building industry '83. Part 1

    International Nuclear Information System (INIS)

    1983-10-01

    The conference heard 52 papers of which 11 were incorporated in INIS. The subject of these was the use of radiometric methods and instruments for nondestructive testing of building materials and ways of testing the quality of concrete during nuclear power plant construction. (J.P.)

  14. Evaluation of phosphatic fertilizers of different solubility for common bean using isotopic methods

    International Nuclear Information System (INIS)

    Garcia Altunaga, Aurelio; Hernandez Barrueta, German; Nuviola Montoya, Antonio; Mendez Perez, Nancy; Herrero Echevarria, Grisel; Drevon, Jean Jacques

    2005-01-01

    Glass house experiments were carried out in the Experimental Station La Renee located in Habana province in the year 2003. The objective of this study was to evaluate the effectiveness of phosphorus (P) sources varying in solubility for common bean (Phaseolus vulgaris L.) nutrition using the isotopic dilution method with 32 P , growing under two soils: Acrisol and Rhodic Ferralsol. The P sources, evaluated in both soils were phosphate rock (PR) Trinidad de Guedes and PR partially solubilized at 50% with H 2 SO 4 , namely FPA 50, whereas single super phosphate (SS) and triple super phosphate (TSP) were used in the Acrisol and Rhodic Ferralsol Soils, respectively. The common bean genotypes were BAT 477, DOR 364, DOR 390 and Censa, and BAT 58, BAT 477, DOR 364 and CC-25-9(N) in the Acrisol and Rhodic Felrrasol soils, respectively. Dry matter production, P extraction, and the fraction and quantity of P in plants obtained from different P sources were evaluated, and P use efficiency of each P fertilizer were calculated. Single and tripe super phosphate and FPA 50 were effective P fertilizers in both soils whereas RF was not. (author) [es

  15. Alternative containment integrity test methods, an overview of possible techniques

    International Nuclear Information System (INIS)

    Spletzer, B.L.

    1986-01-01

    A study is being conducted to develop and analyze alternative methods for testing of containment integrity. The study is focused on techniques for continuously monitoring containment integrity to provide rapid detection of existing leaks, thus providing greater certainty of the integrity of the containment at any time. The study is also intended to develop techniques applicable to the currently required Type A integrated leakage rate tests. A brief discussion of the range of alternative methods currently being considered is presented. The methods include applicability to all major containment types, operating and shutdown plant conditions, and quantitative and qualitative leakage measurements. The techniques are analyzed in accordance with the current state of knowledge of each method. The bulk of the techniques discussed are in the conceptual stage, have not been tested in actual plant conditions, and are presented here as a possible future direction for evaluating containment integrity. Of the methods considered, no single method provides optimum performance for all containment types. Several methods are limited in the types of containment for which they are applicable. The results of the study to date indicate that techniques for continuous monitoring of containment integrity exist for many plants and may be implemented at modest cost

  16. 100 statistical tests

    CERN Document Server

    Kanji, Gopal K

    2006-01-01

    This expanded and updated Third Edition of Gopal K. Kanji's best-selling resource on statistical tests covers all the most commonly used tests with information on how to calculate and interpret results with simple datasets. Each entry begins with a short summary statement about the test's purpose, and contains details of the test objective, the limitations (or assumptions) involved, a brief outline of the method, a worked example, and the numerical calculation. 100 Statistical Tests, Third Edition is the one indispensable guide for users of statistical materials and consumers of statistical information at all levels and across all disciplines.

  17. Standard test methods for characterizing duplex grain sizes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These test methods provide simple guidelines for deciding whether a duplex grain size exists. The test methods separate duplex grain sizes into one of two distinct classes, then into specific types within those classes, and provide systems for grain size characterization of each type. 1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to consult appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.

  18. Standard test method for determining residual stresses by the hole-drilling strain-gage method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 Residual Stress Determination: 1.1.1 This test method specifies a hole-drilling procedure for determining residual stress profiles near the surface of an isotropic linearly elastic material. The test method is applicable to residual stress profile determinations where in-plane stress gradients are small. The stresses may remain approximately constant with depth (“uniform” stresses) or they may vary significantly with depth (“non-uniform” stresses). The measured workpiece may be “thin” with thickness much less than the diameter of the drilled hole or “thick” with thickness much greater than the diameter of the drilled hole. Only uniform stress measurements are specified for thin workpieces, while both uniform and non-uniform stress measurements are specified for thick workpieces. 1.2 Stress Measurement Range: 1.2.1 The hole-drilling method can identify in-plane residual stresses near the measured surface of the workpiece material. The method gives localized measurements that indicate the...

  19. Reliability Verification of DBE Environment Simulation Test Facility by using Statistics Method

    International Nuclear Information System (INIS)

    Jang, Kyung Nam; Kim, Jong Soeg; Jeong, Sun Chul; Kyung Heum

    2011-01-01

    In the nuclear power plant, all the safety-related equipment including cables under the harsh environment should perform the equipment qualification (EQ) according to the IEEE std 323. There are three types of qualification methods including type testing, operating experience and analysis. In order to environmentally qualify the safety-related equipment using type testing method, not analysis or operation experience method, the representative sample of equipment, including interfaces, should be subjected to a series of tests. Among these tests, Design Basis Events (DBE) environment simulating test is the most important test. DBE simulation test is performed in DBE simulation test chamber according to the postulated DBE conditions including specified high-energy line break (HELB), loss of coolant accident (LOCA), main steam line break (MSLB) and etc, after thermal and radiation aging. Because most DBE conditions have 100% humidity condition, in order to trace temperature and pressure of DBE condition, high temperature steam should be used. During DBE simulation test, if high temperature steam under high pressure inject to the DBE test chamber, the temperature and pressure in test chamber rapidly increase over the target temperature. Therefore, the temperature and pressure in test chamber continue fluctuating during the DBE simulation test to meet target temperature and pressure. We should ensure fairness and accuracy of test result by confirming the performance of DBE environment simulation test facility. In this paper, in order to verify reliability of DBE environment simulation test facility, statistics method is used

  20. Application of ISRM testing methods to fracture toughness testing of graphite

    International Nuclear Information System (INIS)

    Hashida, T.; Fukasawa, T.; Takahashi, H.; Ishiyama, S.; Oku, T.

    1987-01-01

    Fracture toughness measurements of nuclear grade graphites, IG11 and PGX, were made by means of AE technique. Tests were conducted on edge-notched round bend bar, edge-notched short bar and round compact tension specimens. These round-shaped specimens used in this study have been proposed for standard fracture toughness tests of rock as a draft of testing standard of International Society for Rock Mechanics (ISRM). Taking the observed nonlinear deformation behavior into account, J-integral approach was utilized to determine the fracture toughness of the graphites. It is shown that the critical J integral determined by AE technique, J iAE , is independent of specimen geometry. Based on this experimental results, the fracture toughness K IC of the graphites was determined from the J iAE values. K IC value of IG11 was 1.04 MPa√m, and 0.77 MPa√m for PGX respectively. Furthermore, the specimen size effect of the fracture toughness determined by the J-integral/AE method is discussed. (author)

  1. Inhibition of Common Cold-Induced Aggravation of Childhood Asthma by Leukotriene Receptor Antagonists

    OpenAIRE

    Shigemi Yoshihara; Hironobu Fukuda; Toshio Abe; Mitsuhiro Nishida; Yumi Yamada; Noriko Kanno; Osamu Arisaka

    2012-01-01

    Background: : Virus infection is an important risk factor for aggravation of childhood asthma. The objective of this study was to examine the effect of drugs on aggravation of asthma induced by a common cold. Methods: : Asthma control was examined in a survey of 1,014 Japanese pediatric patients with bronchial asthma. The occurrence of common cold, asthma control, and drugs used for asthma control were investigated using a modified Childhood Asthma Control Test (C-ACT) for patients aged

  2. Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.

    Science.gov (United States)

    Stern, C H; Jaasma, D R; Champion, M R

    1993-03-01

    A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.

  3. New engine method for biodiesel cetane number testing

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2008-01-01

    Full Text Available Substitution of fossil fuels with fuels that come from part renewable sources has been a subject of many studies and researches in the past decade. Considering the higher cost and limits of production resources, a special attention is focused on raising the energy efficiency of biofuel usage, mainly through optimization of the combustion process. Consequently, in biofuel applications, there is a need for determination of auto-ignition quality expressed by cetane number as a dominant characteristic that influences combustion parameters. The fact that the method for cetane number determination is comparative in nature has led us to try to develop substitute engine method for cetane number determination, by the use of the available laboratory equipment and serial, mono-cylinder engine with direct injection, DMB LDA 450. Description of the method, results of optimization of engine’s working parameters for conduction of the test and method’s Accuracy estimation are given in the paper. The paper also presents the results of domestic biodiesel fuels cetane number testing with the application of described engine method, developed at the Laboratory for internal combustion engines and fuels and lubricants of the Faculty of Mechanical Engineering from Kragujevac, Serbia.

  4. Testing methods of steel wi re ropes at the anchor

    Directory of Open Access Journals (Sweden)

    Stanislav Kropuch

    2012-12-01

    Full Text Available The present paper introduces an application of the acoustic andthermographic method in the defectoscopic testing of immobilesteel wire ropes at the most critical point, the anchor. Firstmeasurements and their results by these new defectoscopic methodsare shown. In defectoscopic tests at the anchor, the widelyused magnetic method gives unreliable results, and therefore presentsa problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enableincreased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  5. File Type Identification of File Fragments using Longest Common Subsequence (LCS)

    Science.gov (United States)

    Rahmat, R. F.; Nicholas, F.; Purnamawati, S.; Sitompul, O. S.

    2017-01-01

    Computer forensic analyst is a person in charge of investigation and evidence tracking. In certain cases, the file needed to be presented as digital evidence was deleted. It is difficult to reconstruct the file, because it often lost its header and cannot be identified while being restored. Therefore, a method is required for identifying the file type of file fragments. In this research, we propose Longest Common Subsequences that consists of three steps, namely training, testing and validation, to identify the file type from file fragments. From all testing results we can conlude that our proposed method works well and achieves 92.91% of accuracy to identify the file type of file fragment for three data types.

  6. Ruling the Commons. Introducing a new methodology for the analysis of historical commons

    Directory of Open Access Journals (Sweden)

    Tine de Moor

    2016-10-01

    Full Text Available Despite significant progress in recent years, the evolution of commons over the long run remains an under-explored area within commons studies. During the last years an international team of historians have worked under the umbrella of the Common Rules Project in order to design and test a new methodology aimed at advancing our knowledge on the dynamics of institutions for collective action – in particular commons. This project aims to contribute to the current debate on commons on three different fronts. Theoretically, it explicitly draws our attention to issues of change and adaptation in the commons – contrasting with more static analyses. Empirically, it highlights the value of historical records as a rich source of information for longitudinal analysis of the functioning of commons. Methodologically, it develops a systematic way of analyzing and comparing commons’ regulations across regions and time, setting a number of variables that have been defined on the basis of the “most common denominators” in commons regulation across countries and time periods. In this paper we introduce the project, describe our sources and methodology, and present the preliminary results of our analysis.

  7. Common factors method to predict the carcass composition tissue in kid goats

    Directory of Open Access Journals (Sweden)

    Helen Fernanda Barros Gomes

    2013-03-01

    Full Text Available The objective of this work was to analyze the interrelations among weights and carcass measures of the longissimus lumborum muscle thickness and area, and of sternum tissue thickness, measured directly on carcass and by ultrasound scan. Measures were taken on live animals and after slaughter to develop models of multiple linear regression, to estimate the composition of shoulder blade, from selected variables in 89 kids of both genders and five breed groups, raised in feedlot system. The variables considered relevant and not redundant on the information they carry, for the common factor analysis, were used in the carcass composition estimate development models. The presuppositions of linear regression models relative to residues were evaluated, the estimated residues were subjected to analysis of variance and the means were compared by the Student t test. Based in these results, the group of 32 initial variables could be reduced to four variables: hot carcass weight, rump perimeter, leg length and tissue height at the fourth sternum bone. The analysis of common factors was shown as an effective technique to study the interrelations among the independent variables. The measures of carcass dimension, alone, did not add any information to hot carcass weight. The carcass muscle weight can be estimated with high precision from simple models, without the need for information related to gender and breed, and they could be built based on carcass weight, which makes it easy to be applied. The fat and bones estimate models were not as accurate.

  8. A new method of ergonomic testing of gloves protecting against cuts and stabs during knife use.

    Science.gov (United States)

    Irzmańska, Emilia; Tokarski, Tomasz

    2017-05-01

    The paper presents a new method of ergonomic evaluation of gloves protecting against cuts and stabs during knife use, consisting of five manual dexterity tests. Two of them were selected based on the available literature and relevant safety standards, and three were developed by the authors. All of the tests were designed to simulate occupational tasks associated with meat processing as performed by the gloved hand in actual workplaces. The tests involved the three most common types of protective gloves (knitted gloves made of a coverspun yarn, metal mesh gloves, and metal mesh gloves with an ergonomic polyurethane tightener) and were conducted on a group of 20 males. The loading on the muscles of the upper limb (adductor pollicis, flexor carpi ulnaris, flexor carpi radialis, and biceps brachii) was measured using surface electromyography. For the obtained muscle activity values, correlations were found between the glove type and loading of the upper limb. ANOVA showed that the activity of all muscles differed significantly between the five tests. A relationship between glove types and electromyographic results was confirmed at a significance level of α = 0.05. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Standard test method for damage to contacting solid surfaces under fretting conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the studying or ranking the susceptibility of candidate materials to fretting corrosion or fretting wear for the purposes of material selection for applications where fretting corrosion or fretting wear can limit serviceability. 1.2 This test method uses a tribological bench test apparatus with a mechanism or device that will produce the necessary relative motion between a contacting hemispherical rider and a flat counterface. The rider is pressed against the flat counterface with a loading mass. The test method is intended for use in room temperature air, but future editions could include fretting in the presence of lubricants or other environments. 1.3 The purpose of this test method is to rub two solid surfaces together under controlled fretting conditions and to quantify the damage to both surfaces in units of volume loss for the test method. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5...

  10. Desalination Processes Evaluation at Common Platform: A Universal Performance Ratio (UPR) Method

    KAUST Repository

    Wakil Shahzad, Muhammad

    2018-01-31

    The inevitable escalation in economic development have serious implications on energy and environment nexus. The International Energy Outlook 2016 (IEO2016) predicted that the Non Organization for Economic Cooperation and Development (non-OECD) countries will lead with 71% rise in energy demand in contrast with only 18% in developed countries from 2012-2040. In Gulf Cooperation Council (GCC) countries, about 40% of primary energy is consumed for cogeneration based power and desalination plants. The cogeneration based plants are struggling with unfair primary fuel cost apportionment to electricity and desalination. Also, the desalination processes performance evaluated based on derived energy, providing misleading selection of processes. There is a need of (i) appropriate primary fuel cost appointment method for multi-purposed plants and (ii) desalination processes performance evaluation method based on primary energy. As a solution, we proposed exergetic analysis for primary fuel percentage apportionment to all components in the cycle according to the quality of working fluid utilized. The proposed method showed that the gas turbine was under charged by 40%, steam turbine was overcharged by 71% and desalination was overcharged by 350% by conventional energetic apportionment methods. We also proposed a new and most suitable desalination processes performance evaluation method based on primary energy, called universal performance ratio (UPR). Since UPR is based on primary energy, it can be used to evaluate any kind of desalination processes, thermally driven, pressure driven & humidification-dehumidification etc. on common platform. We showed that all desalination processes are operating only at 10-13% of thermodynamic limit (TL) of UPR. For future sustainability, desalination must achieve 25-30% of TL and it is only possible either by hybridization of different processes or by innovative membrane materials.

  11. Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients.

    Science.gov (United States)

    Asadian, Simin; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Rezaei, Mansour

    2016-01-01

    An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients' body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (Ptemperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%). Paired t-test demonstrated an acceptable precision with forehead (P=0.132), left (P=0.18) and right (P=0.318) tympanic membranes, oral (P=1.00), and axillary (P=1.00) methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left) for assessing a patient's body temperature in the intensive care units because of high accuracy and acceptable precision.

  12. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    Science.gov (United States)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  13. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  15. Common cause failure analysis methodology for complex systems

    International Nuclear Information System (INIS)

    Wagner, D.P.; Cate, C.L.; Fussell, J.B.

    1977-01-01

    Common cause failure analysis, also called common mode failure analysis, is an integral part of a complex system reliability analysis. This paper extends existing methods of computer aided common cause failure analysis by allowing analysis of the complex systems often encountered in practice. The methods presented here aid in identifying potential common cause failures and also address quantitative common cause failure analysis

  16. 20 CFR 404.1007 - Common-law employee.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Common-law employee. 404.1007 Section 404... Common-law employee. (a) General. The common-law rules on employer-employee status are the basic test for.... Even though you are considered self-employed under the common-law rules, you may still be an employee...

  17. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  18. Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance. 1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level. 1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Immunocapture RT-PCR detection of Bean common mosaic virus and strain blackeye cowpea mosaic in common bean and black gram in India

    DEFF Research Database (Denmark)

    Udayashankar, A.C.; Nayaka, S. Chandra; Niranjana, S.R.

    2012-01-01

    The strains of Bean common mosaic virus (BCMV) and blackeye cowpea mosaic (BICM), genus Potyvirus, were detected from 25 common bean and 14 black gram seeds among 142 seed samples collected from different legume-growing regions of India. The samples were subjected to a growing-on test, an indicator...... plant test, an electron microscopic observations, an enzyme linked immunosorbent assay and an immunocapture RT-PCR. The incidence of the two tested viruses in common bean and black gram seed samples was 1–6% and 0.5–3.5%, respectively in growing-on test evaluations. Electron microscopic observations...

  20. Statistically rigorous calculations do not support common input and long-term synchronization of motor-unit firings

    Science.gov (United States)

    Kline, Joshua C.

    2014-01-01

    Over the past four decades, various methods have been implemented to measure synchronization of motor-unit firings. In this work, we provide evidence that prior reports of the existence of universal common inputs to all motoneurons and the presence of long-term synchronization are misleading, because they did not use sufficiently rigorous statistical tests to detect synchronization. We developed a statistically based method (SigMax) for computing synchronization and tested it with data from 17,736 motor-unit pairs containing 1,035,225 firing instances from the first dorsal interosseous and vastus lateralis muscles—a data set one order of magnitude greater than that reported in previous studies. Only firing data, obtained from surface electromyographic signal decomposition with >95% accuracy, were used in the study. The data were not subjectively selected in any manner. Because of the size of our data set and the statistical rigor inherent to SigMax, we have confidence that the synchronization values that we calculated provide an improved estimate of physiologically driven synchronization. Compared with three other commonly used techniques, ours revealed three types of discrepancies that result from failing to use sufficient statistical tests necessary to detect synchronization. 1) On average, the z-score method falsely detected synchronization at 16 separate latencies in each motor-unit pair. 2) The cumulative sum method missed one out of every four synchronization identifications found by SigMax. 3) The common input assumption method identified synchronization from 100% of motor-unit pairs studied. SigMax revealed that only 50% of motor-unit pairs actually manifested synchronization. PMID:25210152

  1. Sensitivity of Equated Aggregate Scores to the Treatment of Misbehaving Common Items

    Science.gov (United States)

    Michaelides, Michalis P.

    2010-01-01

    The delta-plot method (Angoff, 1972) is a graphical technique used in the context of test equating for identifying common items with aberrant changes in their item difficulties across administrations or alternate forms. This brief research report explores the effects on equated aggregate scores when delta-plot outliers are either retained in or…

  2. Evaluation of snubber functional test methods: Tier 1

    International Nuclear Information System (INIS)

    Brown, D.P.

    1993-07-01

    The objective of the research is to establish technical bases in support of efforts on the part of the Snubber Utility Group (SNUG) and the Subsection ISTD Working Group of the ASME O ampersand M Code in developing guidelines and methodologies for snubber functional testing to ensure that snubbers are tested in a manner that ensures reliable and meaningful test results. The methodology used in this research includes both a review of available industry information as well as the testing of different snubber models using various test machines. Information is provided pertaining to current industry practices in regard to snubber testing including recommended test procedures, technical description of various test machines, and the number and types of snubbers used in the nuclear power industry. A review of previous test methodology research conducted by the Snubber Utility Group is also included. The effects of variations in controllable test parameters on snubber test results are discussed. Also included are the results of confirmatory tests in which various snubber models were tested using various test machines. Recommendations are provided for standard test methods to be included in Subsection ISTD of the ASME O ampersand M Code [4]. General information and recommendations are provided that may be used by utility personnel in specifying snubber test equipment that is most suited for plant-specific needs as well as information that may be effectively used in the review and interpretation of test results

  3. An accelerated test method of luminous flux depreciation for LED luminaires and lamps

    International Nuclear Information System (INIS)

    Qian, C.; Fan, X.J.; Fan, J.J.; Yuan, C.A.; Zhang, G.Q.

    2016-01-01

    Light Emitting Diode (LED) luminaires and lamps are energy-saving and environmental friendly alternatives to traditional lighting products. However, current luminous flux depreciation test at luminaire and lamp level requires a minimum of 6000 h testing, which is even longer than the product development cycle time. This paper develops an accelerated test method for luminous flux depreciation to reduce the test time within 2000 h at an elevated temperature. The method is based on lumen maintenance boundary curve, obtained from a collection of LED source lumen depreciation data, known as LM-80 data. The exponential decay model and Arrhenius acceleration relationship are used to determine the new threshold of lumen maintenance and acceleration factor. The proposed method has been verified by a number of simulation studies and experimental data for a wide range of LED luminaire and lamp types from both internal and external experiments. The qualification results obtained by the accelerated test method agree well with traditional 6000 h tests. - Highlights: • We develop an accelerated test method for LED luminaires and lamps. • The method is proposed based on a “Boundary Curve” concept. • The parameters of the boundary curve are extracted from LM-80 test reports. • Qualification results from the proposed method agree with ES requirements.

  4. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  5. Test Method for High β Particle Emission Rate of 63Ni Source Plate

    OpenAIRE

    ZHANG Li-feng

    2015-01-01

    For the problem of measurement difficulties of β particle emission rate of Ni-63 source plate used for Ni-63 betavoltaic battery, a relative test method of scintillation current method was erected according to the measurement principle of scintillation detector.β particle emission rate of homemade Ni-63 source plate was tested by the method, and the test results were analysed and evaluated, it was initially thought that scintillation current method was a feasible way of testing β particle emi...

  6. Interesting Developments in Testing Methods Applied to Foundation Piles

    Science.gov (United States)

    Sobala, Dariusz; Tkaczyński, Grzegorz

    2017-10-01

    Both: piling technologies and pile testing methods are a subject of current development. New technologies, providing larger diameters or using in-situ materials, are very demanding in terms of providing proper quality of execution of works. That concerns the material quality and continuity which define the integral strength of pile. On the other side we have the capacity of the ground around the pile and its ability to carry the loads transferred by shaft and pile base. Inhomogeneous nature of soils and a relatively small amount of tested piles imposes very good understanding of small amount of results. In some special cases the capacity test itself form an important cost in the piling contract. This work presents a brief description of selected testing methods and authors remarks based on cooperation with Universities constantly developing new ideas. Paper presents some experience based remarks on integrity testing by means of low energy impact (low strain) and introduces selected (Polish) developments in the field of closed-end pipe piles testing based on bi-directional loading, similar to Osterberg idea, but without sacrificial hydraulic jack. Such test is suitable especially when steel piles are used for temporary support in the rivers, where constructing of conventional testing appliance with anchor piles or kentledge meets technical problems. According to the author’s experience, such tests were not yet used on the building site but they bring a real potential especially, when the displacement control can be provided from the river bank using surveying techniques.

  7. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Development of test bolus tracking method and usefulness in coronary CT angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Takayoshi; Takahashi, Daichi

    2009-01-01

    The test bolus tracking (TBT) method is a new injection method of contrast medium that we developed. The TBT method is an injection technique that continuously performs the test bolus injection and the main bolus injection, such that the best acquisition of scan timing and the improvement of examination efficiency can be expected. We compared the TBT method and the test injection method by coronary CT angiography. The results demonstrated that the contrast enhancement of the coronary arteries was high and the variation of the CT value was also small in the TBT method. When the scan timing expected by the TI method and the TBT method were compared, it was different of two seconds or more by the case with 43%. However, the variation of CT value was small for the TBT method in these cases. Therefore, the TBT method is a very useful method for coronary CT angiography (CCTA). (author)

  9. Experimental Study of WBFC method for testing electromagnetic immunity of integrated circuits

    OpenAIRE

    香川, 直己; カガワ, ナオキ; Naoki, KAGAWA

    2004-01-01

    The author made a workbench faraday cage, WBFC, in order to estimate performance of the WBFC method for the measurement of common mode noise immunity of integrated circuits. In this report, characteristics of the constructed workbench faraday cage and results of experimental study of effects of the common mode noise on a circuit board including an electronic device are shown. Selected DUT, LM324 is popular operational amplifier for electrical circuits in vehicles.

  10. A new Laplace transformation method for dynamic testing of solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Perers, Bengt; Fan, Jianhua

    2015-01-01

    A new dynamic method for solar collector testing is developed. It is characterized by using the Laplace transformation technique to solve the differential governing equation. The new method was inspired by the so called New Dynamic Method (NDM) (Amer E. et al (1999) [1]) but totally different....... By integration of the Laplace transformation technique with the Quasi Dynamic Test (QDT) model (Fischer S. et al (2004) [2]), the Laplace – QDT (L-QDT) model is derived. Two experimental methods are then introduced. One is the shielding method which needs to shield and un-shield solar collector continuously...

  11. Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests

    Science.gov (United States)

    Sinharay, Sandip

    2018-01-01

    Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…

  12. Testing statistical significance scores of sequence comparison methods with structure similarity

    Directory of Open Access Journals (Sweden)

    Leunissen Jack AM

    2006-10-01

    Full Text Available Abstract Background In the past years the Smith-Waterman sequence comparison algorithm has gained popularity due to improved implementations and rapidly increasing computing power. However, the quality and sensitivity of a database search is not only determined by the algorithm but also by the statistical significance testing for an alignment. The e-value is the most commonly used statistical validation method for sequence database searching. The CluSTr database and the Protein World database have been created using an alternative statistical significance test: a Z-score based on Monte-Carlo statistics. Several papers have described the superiority of the Z-score as compared to the e-value, using simulated data. We were interested if this could be validated when applied to existing, evolutionary related protein sequences. Results All experiments are performed on the ASTRAL SCOP database. The Smith-Waterman sequence comparison algorithm with both e-value and Z-score statistics is evaluated, using ROC, CVE and AP measures. The BLAST and FASTA algorithms are used as reference. We find that two out of three Smith-Waterman implementations with e-value are better at predicting structural similarities between proteins than the Smith-Waterman implementation with Z-score. SSEARCH especially has very high scores. Conclusion The compute intensive Z-score does not have a clear advantage over the e-value. The Smith-Waterman implementations give generally better results than their heuristic counterparts. We recommend using the SSEARCH algorithm combined with e-values for pairwise sequence comparisons.

  13. Methods study of homogeneity and stability test from cerium oxide CRM candidate

    International Nuclear Information System (INIS)

    Samin; Susanna TS

    2016-01-01

    The methods study of homogeneity and stability test from cerium oxide CRM candidate has been studied based on ISO 13258 and KAN DP. 01. 34. The purpose of this study was to select the test method homogeneity and stability tough on making CRM cerium oxide. Prepared 10 sub samples of cerium oxide randomly selected types of analytes which represent two compounds, namely CeO_2 and La_2O_3. At 10 sub sample is analyzed CeO_2 and La_2O_3 contents in duplicate with the same analytical methods, by the same analyst, and in the same laboratory. Data analysis results calculated statistically based on ISO 13528 and KAN DP.01.34. According to ISO 13528 Cerium Oxide samples said to be homogeneous if Ss ≤ 0.3 σ and is stable if | Xr – Yr | ≤ 0.3 σ. In this study, the data of homogeneity test obtained CeO_2 is Ss = 2.073 x 10-4 smaller than 0.3 σ (0.5476) and the stability test obtained | Xr - Yr | = 0.225 and the price is < 0.3 σ. Whereas for La_2O_3, the price for homogeneity test obtained Ss = 1.649 x 10-4 smaller than 0.3 σ (0.4865) and test the stability of the price obtained | Xr - Yr | = 0.2185 where the price is < 0.3 σ. Compared with the method from KAN, a sample of cerium oxide has also been homogenized for Fcalc < Ftable and stable, because | Xi - Xhm | < 0.3 x n IQR. Provided that the results of the evaluation homogeneity and stability test from CeO_2 CRM candidate test data were processed using statistical methods ISO 13528 is not significantly different with statistical methods from KAN DP.01.34, which together meet the requirements of a homogeneous and stable. So the test method homogeneity and stability test based on ISO 13528 can be used to make CRM cerium oxide. (author)

  14. Self-test Monte Carlo method

    International Nuclear Information System (INIS)

    Ohta, Shigemi

    1996-01-01

    The Self-Test Monte Carlo (STMC) method resolves the main problems in using algebraic pseudo-random numbers for Monte Carlo (MC) calculations: that they can interfere with MC algorithms and lead to erroneous results, and that such an error often cannot be detected without known exact solution. STMC is based on good randomness of about 10 10 bits available from physical noise or transcendental numbers like π = 3.14---. Various bit modifiers are available to get more bits for applications that demands more than 10 10 random bits such as lattice quantum chromodynamics (QCD). These modifiers are designed so that a) each of them gives a bit sequence comparable in randomness as the original if used separately from each other, and b) their mutual interference when used jointly in a single MC calculation is adjustable. Intermediate data of the MC calculation itself are used to quantitatively test and adjust the mutual interference of the modifiers in respect of the MC algorithm. STMC is free of systematic error and gives reliable statistical error. Also it can be easily implemented on vector and parallel supercomputers. (author)

  15. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  16. Testing methods of ECR ion source experimental platform

    International Nuclear Information System (INIS)

    Zhou Changgeng; Hu Yonghong; Li Yan

    2006-12-01

    The principle and structure of ECR ion source experimental platform were introduce. The testing methods of the parameters of single main component and the comprehensive parameters under the condition of certain beam current and beam spot diameter were summarized in process of manufacturing. Some appropriate testing dates were given. The existent questions (the parameters of plasma density in discharge chamber and accurate hydrogen flow, etc. can not be measured in operation) and resolutions were also put forward. (authors)

  17. Effect of testing methods on the bond strength of resin to zirconia-alumina ceramic : microtensile versus shear test

    NARCIS (Netherlands)

    Valandro, Luiz F.; Ozcan, Mutlu; Amaral, Regina; Vanderlei, Aleska; Bottino, Marco A.

    2008-01-01

    This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC)

  18. Quantitative Evaluation of gamma-Spectrum Analysis Methods using IAEA Test Spectra

    DEFF Research Database (Denmark)

    Nielsen, Sven Poul

    1982-01-01

    A description is given of a γ-spectrum analysis method based on nonlinear least-squares fitting. The quality of the method is investigated by using statistical tests on the results from analyses of IAEA test spectra. By applying an empirical correction factor of 0.75 to the calculated peak-area u...

  19. Representative assessment of long bone shaft biomechanical properties: an optimized testing method

    NARCIS (Netherlands)

    Bramer, J. A.; Barentsen, R. H.; vd Elst, M.; de Lange, E. S.; Patka, P.; Haarman, H. J.

    1998-01-01

    Whole bone bending tests are commonly used in mechanical evaluation of long bones. Reliable information about the midshaft can only be obtained if the bending moment is uniformly distributed along the shaft, and if the distribution of the bending stress is not adversely influenced by rigid clamping

  20. A test of inflated zeros for Poisson regression models.

    Science.gov (United States)

    He, Hua; Zhang, Hui; Ye, Peng; Tang, Wan

    2017-01-01

    Excessive zeros are common in practice and may cause overdispersion and invalidate inference when fitting Poisson regression models. There is a large body of literature on zero-inflated Poisson models. However, methods for testing whether there are excessive zeros are less well developed. The Vuong test comparing a Poisson and a zero-inflated Poisson model is commonly applied in practice. However, the type I error of the test often deviates seriously from the nominal level, rendering serious doubts on the validity of the test in such applications. In this paper, we develop a new approach for testing inflated zeros under the Poisson model. Unlike the Vuong test for inflated zeros, our method does not require a zero-inflated Poisson model to perform the test. Simulation studies show that when compared with the Vuong test our approach not only better at controlling type I error rate, but also yield more power.

  1. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  2. Mirror bootstrap method for testing hypotheses of one mean

    OpenAIRE

    Varvak, Anna

    2012-01-01

    The general philosophy for bootstrap or permutation methods for testing hypotheses is to simulate the variation of the test statistic by generating the sampling distribution which assumes both that the null hypothesis is true, and that the data in the sample is somehow representative of the population. This philosophy is inapplicable for testing hypotheses for a single parameter like the population mean, since the two assumptions are contradictory (e.g., how can we assume both that the mean o...

  3. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  4. Exact association test for small size sequencing data.

    Science.gov (United States)

    Lee, Joowon; Lee, Seungyeoun; Jang, Jin-Young; Park, Taesung

    2018-04-20

    Recent statistical methods for next generation sequencing (NGS) data have been successfully applied to identifying rare genetic variants associated with certain diseases. However, most commonly used methods (e.g., burden tests and variance-component tests) rely on large sample sizes. Notwithstanding, due to its-still high cost, NGS data is generally restricted to small sample sizes, that cannot be analyzed by most existing methods. In this work, we propose a new exact association test for sequencing data that does not require a large sample approximation, which is applicable to both common and rare variants. Our method, based on the Generalized Cochran-Mantel-Haenszel (GCMH) statistic, was applied to NGS datasets from intraductal papillary mucinous neoplasm (IPMN) patients. IPMN is a unique pancreatic cancer subtype that can turn into an invasive and hard-to-treat metastatic disease. Application of our method to IPMN data successfully identified susceptible genes associated with progression of IPMN to pancreatic cancer. Our method is expected to identify disease-associated genetic variants more successfully, and corresponding signal pathways, improving our understanding of specific disease's etiology and prognosis.

  5. Testing for common cycles in non-stationary VARs with varied frecquency data

    NARCIS (Netherlands)

    Götz, T.B.; Hecq, A.W.; Urbain, J.R.Y.J.

    2013-01-01

    This paper proposes a new way for detecting the presence of common cyclical features when several time series are observed/sampled at different frequencies, hence generalizing the common-frequency approach introduced by Engle and Kozicki (1993) and Vahid and Engle (1993). We start with the

  6. Examining Method Effect of Synonym and Antonym Test in Verbal Abilities Measure

    Directory of Open Access Journals (Sweden)

    Wahyu Widhiarso

    2015-08-01

    Full Text Available Many researchers have assumed that different methods could be substituted to measure the same attributes in assessment. Various models have been developed to accommodate the amount of variance attributable to the methods but these models application in empirical research is rare. The present study applied one of those models to examine whether method effects were presents in synonym and antonym tests. Study participants were 3,469 applicants to graduate school. The instrument used was the Graduate Academic Potential Test (PAPS, which includes synonym and antonym questions to measure verbal abilities. Our analysis showed that measurement models that using correlated trait–correlated methods minus one, CT-C(M–1, that separated trait and method effect into distinct latent constructs yielded slightly better values for multiple goodness-of-fit indices than one factor model. However, either for the synonym or antonym items, the proportion of variance accounted for by the method is smaller than trait variance. The correlation between factor scores of both methods is high (r = 0.994. These findings confirm that synonym and antonym tests represent the same attribute so that both tests cannot be treated as two unique methods for measuring verbal ability.

  7. Examining Method Effect of Synonym and Antonym Test in Verbal Abilities Measure.

    Science.gov (United States)

    Widhiarso, Wahyu; Haryanta

    2015-08-01

    Many researchers have assumed that different methods could be substituted to measure the same attributes in assessment. Various models have been developed to accommodate the amount of variance attributable to the methods but these models application in empirical research is rare. The present study applied one of those models to examine whether method effects were presents in synonym and antonym tests. Study participants were 3,469 applicants to graduate school. The instrument used was the Graduate Academic Potential Test (PAPS), which includes synonym and antonym questions to measure verbal abilities. Our analysis showed that measurement models that using correlated trait-correlated methods minus one, CT-C(M-1), that separated trait and method effect into distinct latent constructs yielded slightly better values for multiple goodness-of-fit indices than one factor model. However, either for the synonym or antonym items, the proportion of variance accounted for by the method is smaller than trait variance. The correlation between factor scores of both methods is high (r = 0.994). These findings confirm that synonym and antonym tests represent the same attribute so that both tests cannot be treated as two unique methods for measuring verbal ability.

  8. Standard test methods for determining chemical durability of nuclear, hazardous, and mixed waste glasses and multiphase glass ceramics: The product consistency test (PCT)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These product consistency test methods A and B evaluate the chemical durability of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, and/or multiphase glass ceramic waste forms hereafter collectively referred to as “glass waste forms” by measuring the concentrations of the chemical species released to a test solution. 1.1.1 Test Method A is a seven-day chemical durability test performed at 90 ± 2°C in a leachant of ASTM-Type I water. The test method is static and conducted in stainless steel vessels. Test Method A can specifically be used to evaluate whether the chemical durability and elemental release characteristics of nuclear, hazardous, and mixed glass waste forms have been consistently controlled during production. This test method is applicable to radioactive and simulated glass waste forms as defined above. 1.1.2 Test Method B is a durability test that allows testing at various test durations, test temperatures, mesh size, mass of sample, leachant volume, a...

  9. A permutation-based multiple testing method for time-course microarray experiments

    Directory of Open Access Journals (Sweden)

    George Stephen L

    2009-10-01

    Full Text Available Abstract Background Time-course microarray experiments are widely used to study the temporal profiles of gene expression. Storey et al. (2005 developed a method for analyzing time-course microarray studies that can be applied to discovering genes whose expression trajectories change over time within a single biological group, or those that follow different time trajectories among multiple groups. They estimated the expression trajectories of each gene using natural cubic splines under the null (no time-course and alternative (time-course hypotheses, and used a goodness of fit test statistic to quantify the discrepancy. The null distribution of the statistic was approximated through a bootstrap method. Gene expression levels in microarray data are often complicatedly correlated. An accurate type I error control adjusting for multiple testing requires the joint null distribution of test statistics for a large number of genes. For this purpose, permutation methods have been widely used because of computational ease and their intuitive interpretation. Results In this paper, we propose a permutation-based multiple testing procedure based on the test statistic used by Storey et al. (2005. We also propose an efficient computation algorithm. Extensive simulations are conducted to investigate the performance of the permutation-based multiple testing procedure. The application of the proposed method is illustrated using the Caenorhabditis elegans dauer developmental data. Conclusion Our method is computationally efficient and applicable for identifying genes whose expression levels are time-dependent in a single biological group and for identifying the genes for which the time-profile depends on the group in a multi-group setting.

  10. Applicability and interpretation of fracture test methods for metals

    International Nuclear Information System (INIS)

    Langford, W.J.

    1978-05-01

    Fracture tests are conducted usually out of a conviction (sometimes only vaguely defined) that they will guarantee a certain level of protecton from metal failure. Qualitative tests, such as the Charpy V-notch, produce results which cannot be rigorously related to a measure of fracture tolerance: rather, they indicate metal quality so that fracture tolerance may be inferred. Quantitative tests on the other hand provide parameters which may be used directly in equations to determine the likelihood of fracture. Both types of tests have limitations which should be understood: the paper tries to provide guidance on the relative merits of either approach for a particular purpose, and gives an insight into near-future test methods which will extend the range of usefullness of quantitative tests. (author)

  11. Standard test method for splitting tensile strength for brittle nuclear waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This test method is used to measure the static splitting tensile strength of cylindrical specimens of brittle nuclear waste forms. It provides splitting tensile-strength data that can be used to compare the strength of waste forms when tests are done on one size of specimen. 1.2 The test method is applicable to glass, ceramic, and concrete waste forms that are sufficiently homogeneous (Note 1) but not to coated-particle, metal-matrix, bituminous, or plastic waste forms, or concretes with large-scale heterogeneities. Cementitious waste forms with heterogeneities >1 to 2 mm and 5 mm can be tested using this procedure provided the specimen size is increased from the reference size of 12.7 mm diameter by 6 mm length, to 51 mm diameter by 100 mm length, as recommended in Test Method C 496 and Practice C 192. Note 1—Generally, the specimen structural or microstructural heterogeneities must be less than about one-tenth the diameter of the specimen. 1.3 This test method can be used as a quality control chec...

  12. Functional tests of a prototype for the CMS-ATLAS common non-event data handling framework

    CERN Document Server

    Formica, Andrea; The ATLAS collaboration

    2016-01-01

    Since the 2014 the experiments ATLAS and CMS have started to share a common vision for the Condition Database infrastructure required for the forthcoming LHC runs. The large commonality in the use cases to be satisfied has allowed to agree to an overall design solution which could meet the requirements for both experiments. A first prototype implementing these solutions has been completed in 2015 and made available to both the experiments. The prototype is based on a web service implementing a REST api with a set of functions for the management of conditions data. The objects which constitute the elements of the data model are seen as resources on which CRUD operations can be performed via standard HTTP methods. The choice to insert a REST api in the architecture has several advantages: 1) the conditions data are exchanged in a neutral format ( JSON or XML), allowing to be processed by different technologies in different frameworks. 2) the client is agnostic with respect to the underlying technology adopted f...

  13. Algorithms for solving common fixed point problems

    CERN Document Server

    Zaslavski, Alexander J

    2018-01-01

    This book details approximate solutions to common fixed point problems and convex feasibility problems in the presence of perturbations. Convex feasibility problems search for a common point of a finite collection of subsets in a Hilbert space; common fixed point problems pursue a common fixed point of a finite collection of self-mappings in a Hilbert space. A variety of algorithms are considered in this book for solving both types of problems, the study of which has fueled a rapidly growing area of research. This monograph is timely and highlights the numerous applications to engineering, computed tomography, and radiation therapy planning. Totaling eight chapters, this book begins with an introduction to foundational material and moves on to examine iterative methods in metric spaces. The dynamic string-averaging methods for common fixed point problems in normed space are analyzed in Chapter 3. Dynamic string methods, for common fixed point problems in a metric space are introduced and discussed in Chapter ...

  14. A Common Opinion on Croatian Journalists Tested by PR Profesionals

    Directory of Open Access Journals (Sweden)

    Ana Sušić

    2016-06-01

    Full Text Available Journalists in Croatia do not enjoy formidable reputation among the public due to the beliefs that their writing is, inter alia, biased, inclined to sensationalism and manipulation, and that they lack analytical skills (see also Kanižaj and Skoko, 2010; Jokoš and Kanižaj, 2012. The aim of this research is to verify how journalistic work and journalistic profession in Croatia is perceived by corporate sector PR professionals who cooperate with them on a daily basis. Using the method of in-depth interviews conducted with eight PR professionals, the reputation of Croatian journalists has been put to the test. The research revealed that the interviewed PR professionals perceive Croatian journalists mostly as superficial and biased reporters who search for sensation rather than the truth. However, it turned out that the interviewees do not percieve journalists as being envious, irresponsible or corruptible. They even demonstrated true understanding of the difficulties that journalists encounter, especially in the context of the economic crisis.

  15. The four-principle formulation of common morality is at the core of bioethics mediation method.

    Science.gov (United States)

    Ahmadi Nasab Emran, Shahram

    2015-08-01

    Bioethics mediation is increasingly used as a method in clinical ethics cases. My goal in this paper is to examine the implicit theoretical assumptions of the bioethics mediation method developed by Dubler and Liebman. According to them, the distinguishing feature of bioethics mediation is that the method is useful in most cases of clinical ethics in which conflict is the main issue, which implies that there is either no real ethical issue or if there were, they are not the key to finding a resolution. I question the tacit assumption of non-normativity of the mediation method in bioethics by examining the various senses in which bioethics mediation might be non-normative or neutral. The major normative assumption of the mediation method is the existence of common morality. In addition, the four-principle formulation of the theory articulated by Beauchamp and Childress implicitly provides the normative content for the method. Full acknowledgement of the theoretical and normative assumptions of bioethics mediation helps clinical ethicists better understand the nature of their job. In addition, the need for a robust philosophical background even in what appears to be a purely practical method of mediation cannot be overemphasized. Acknowledgement of the normative nature of bioethics mediation method necessitates a more critical attitude of the bioethics mediators towards the norms they usually take for granted uncritically as valid.

  16. Study on the Related Teaching of "Narrative Creation" and "Narrative Reading" : Making use of "the method of narrative" as a common element

    OpenAIRE

    Mitoh, Yasuhiro

    2014-01-01

    This study has explored the related teaching of "narrative creation" and "narrative reading". For this study, I hypothesized as follows. There is "the method of narrative" in "narrative creation" and "narrative reading" as a common element. By this related teaching that used "the method of narrative" as a common element, children’s ability of "narrative creation" and "narrative reading" will increase. As a result of this study, the following conclusions were obtained. Children surely make use...

  17. THE USEFULNESS OF USER TESTING METHODS IN IDENTIFYING PROBLEMS ON UNIVERSITY WEBSITES

    Directory of Open Access Journals (Sweden)

    Layla Hasan

    2014-10-01

    Full Text Available This paper aims to investigate the usefulness of three user testing methods (observation, and using both quantitative and qualitative data from a post-test questionnaire in terms of their ability or inability to find specific usability problems on university websites. The results showed that observation was the best method, compared to the other two, in identifying large numbers of major and minor usability problems on university websites. The results also showed that employing qualitative data from a post-test questionnaire was a useful complementary method since this identified additional usability problems that were not identified by the observation method. However, the results showed that the quantitative data from the post-test questionnaire were inaccurate and ineffective in terms of identifying usability problems on such websites.

  18. Instrumentation and measurement method for the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Chu, In Chul; Eu, Dong Jin; Kang, Kyong Ho; Kim, Yeon Sik; Song, Chul Hwa; Baek, Won Pil

    2007-03-15

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS is constructed by thermal-hydraulic safety research division in KAERI. The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400 which is a Korean evolution type nuclear reactors. A total 1300 instrumentations is equipped in the ATLAS test facility. In this report, the instrumentation of ATLAS test facility and related measurement methods were introduced.

  19. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Development of laboratory acceleration test method for service life prediction of concrete structures

    International Nuclear Information System (INIS)

    Cho, M. S.; Song, Y. C.; Bang, K. S.; Lee, J. S.; Kim, D. K.

    1999-01-01

    Service life prediction of nuclear power plants depends on the application of history of structures, field inspection and test, the development of laboratory acceleration tests, their analysis method and predictive model. In this study, laboratory acceleration test method for service life prediction of concrete structures and application of experimental test results are introduced. This study is concerned with environmental condition of concrete structures and is to develop the acceleration test method for durability factors of concrete structures e.g. carbonation, sulfate attack, freeze-thaw cycles and shrinkage-expansion etc

  1. A Novel Vibration Mode Testing Method for Cylindrical Resonators Based on Microphones

    Directory of Open Access Journals (Sweden)

    Yongmeng Zhang

    2015-01-01

    Full Text Available Non-contact testing is an important method for the study of the vibrating characteristic of cylindrical resonators. For the vibratory cylinder gyroscope excited by piezo-electric electrodes, mode testing of the cylindrical resonator is difficult. In this paper, a novel vibration testing method for cylindrical resonators is proposed. This method uses a MEMS microphone, which has the characteristics of small size and accurate directivity, to measure the vibration of the cylindrical resonator. A testing system was established, then the system was used to measure the vibration mode of the resonator. The experimental results show that the orientation resolution of the node of the vibration mode is better than 0.1°. This method also has the advantages of low cost and easy operation. It can be used in vibration testing and provide accurate results, which is important for the study of the vibration mode and thermal stability of vibratory cylindrical gyroscopes.

  2. Poisson Approximation-Based Score Test for Detecting Association of Rare Variants.

    Science.gov (United States)

    Fang, Hongyan; Zhang, Hong; Yang, Yaning

    2016-07-01

    Genome-wide association study (GWAS) has achieved great success in identifying genetic variants, but the nature of GWAS has determined its inherent limitations. Under the common disease rare variants (CDRV) hypothesis, the traditional association analysis methods commonly used in GWAS for common variants do not have enough power for detecting rare variants with a limited sample size. As a solution to this problem, pooling rare variants by their functions provides an efficient way for identifying susceptible genes. Rare variant typically have low frequencies of minor alleles, and the distribution of the total number of minor alleles of the rare variants can be approximated by a Poisson distribution. Based on this fact, we propose a new test method, the Poisson Approximation-based Score Test (PAST), for association analysis of rare variants. Two testing methods, namely, ePAST and mPAST, are proposed based on different strategies of pooling rare variants. Simulation results and application to the CRESCENDO cohort data show that our methods are more powerful than the existing methods. © 2016 John Wiley & Sons Ltd/University College London.

  3. Diagnostic tests for Helicobacter pylori : A prospective evaluation of their accuracy, without selecting a single test as the gold standard

    NARCIS (Netherlands)

    Thijs, J C; van Zwet, A A; Thijs, W J; Oey, H B; Karrenbeld, A; Stellaard, F; Luijt, D S; Meyer, B C; Kleibeuker, J H

    1996-01-01

    OBJECTIVE: To assess the accuracy of six commonly used diagnostic tests for Helicobacter pylori in a prospective study without using any specific test as the gold standard (the patient was regarded as H. pylori-infected if two or more tests, whatever their nature, were positive). METHODS: In 105

  4. Comparison of methods for estimating the cost of human immunodeficiency virus-testing interventions.

    Science.gov (United States)

    Shrestha, Ram K; Sansom, Stephanie L; Farnham, Paul G

    2012-01-01

    The Centers for Disease Control and Prevention (CDC), Division of HIV/AIDS Prevention, spends approximately 50% of its $325 million annual human immunodeficiency virus (HIV) prevention funds for HIV-testing services. An accurate estimate of the costs of HIV testing in various settings is essential for efficient allocation of HIV prevention resources. To assess the costs of HIV-testing interventions using different costing methods. We used the microcosting-direct measurement method to assess the costs of HIV-testing interventions in nonclinical settings, and we compared these results with those from 3 other costing methods: microcosting-staff allocation, where the labor cost was derived from the proportion of each staff person's time allocated to HIV testing interventions; gross costing, where the New York State Medicaid payment for HIV testing was used to estimate program costs, and program budget, where the program cost was assumed to be the total funding provided by Centers for Disease Control and Prevention. Total program cost, cost per person tested, and cost per person notified of new HIV diagnosis. The median costs per person notified of a new HIV diagnosis were $12 475, $15 018, $2697, and $20 144 based on microcosting-direct measurement, microcosting-staff allocation, gross costing, and program budget methods, respectively. Compared with the microcosting-direct measurement method, the cost was 78% lower with gross costing, and 20% and 61% higher using the microcosting-staff allocation and program budget methods, respectively. Our analysis showed that HIV-testing program cost estimates vary widely by costing methods. However, the choice of a particular costing method may depend on the research question being addressed. Although program budget and gross-costing methods may be attractive because of their simplicity, only the microcosting-direct measurement method can identify important determinants of the program costs and provide guidance to improve

  5. Significance tests in mutagen screening: another method considering historical control frequencies

    International Nuclear Information System (INIS)

    Traut, H.

    1983-01-01

    Recently a method has been devised for testing the significance of the difference between a mutation frequency observed after chemical treatment or iradiation and the historical ('stable') control frequency. Another test is proposed serving the same purpose. Both methods are applied to several examples (experimental frequency versus historical control frequency). The results (P values) obtained agree well. (author)

  6. Microbial activity in aquatic environments measured by dimethyl sulfoxide reduction and intercomparison with commonly used methods.

    Science.gov (United States)

    Griebler, C; Slezak, D

    2001-01-01

    A new method to determine microbial (bacterial and fungal) activity in various freshwater habitats is described. Based on microbial reduction of dimethyl sulfoxide (DMSO) to dimethyl sulfide (DMS), our DMSO reduction method allows measurement of the respiratory activity in interstitial water, as well as in the water column. DMSO is added to water samples at a concentration (0.75% [vol/vol] or 106 mM) high enough to compete with other naturally occurring electron acceptors, as determined with oxygen and nitrate, without stimulating or inhibiting microbial activity. Addition of NaN(3), KCN, and formaldehyde, as well as autoclaving, inhibited the production of DMS, which proves that the reduction of DMSO is a biotic process. DMSO reduction is readily detectable via the formation of DMS even at low microbial activities. All water samples showed significant DMSO reduction over several hours. Microbially reduced DMSO is recovered in the form of DMS from water samples by a purge and trap system and is quantified by gas chromatography and detection with a flame photometric detector. The DMSO reduction method was compared with other methods commonly used for assessment of microbial activity. DMSO reduction activity correlated well with bacterial production in predator-free batch cultures. Cell-production-specific DMSO reduction rates did not differ significantly in batch cultures with different nutrient regimes but were different in different growth phases. Overall, a cell-production-specific DMSO reduction rate of 1.26 x 10(-17) +/- 0. 12 x 10(-17) mol of DMS per produced cell (mean +/- standard error; R(2) = 0.78) was calculated. We suggest that the relationship of DMSO reduction rates to thymidine and leucine incorporation is linear (the R(2) values ranged from 0.783 to 0.944), whereas there is an exponential relationship between DMSO reduction rates and glucose uptake, as well as incorporation (the R(2) values ranged from 0.821 to 0.931). Based on our results, we

  7. Testing the multi-configuration time-dependent Hartree-Fock method

    International Nuclear Information System (INIS)

    Zanghellini, Juergen; Kitzler, Markus; Brabec, Thomas; Scrinzi, Armin

    2004-01-01

    We test the multi-configuration time-dependent Hartree-Fock method as a new approach towards the numerical calculation of dynamical processes in multi-electron systems using the harmonic quantum dot and one-dimensional helium in strong laser pulses as models. We find rapid convergence for quantities such as ground-state population, correlation coefficient and single ionization towards the exact results. The method converges, where the time-dependent Hartree-Fock method fails qualitatively

  8. The anchors of steel wire ropes, testing methods and their results

    Directory of Open Access Journals (Sweden)

    J. Krešák

    2012-10-01

    Full Text Available The present paper introduces an application of the acoustic and thermographic method in the defectoscopic testing of immobile steel wire ropes at the most critical point, the anchor. First measurements and their results by these new defectoscopic methods are shown. In defectoscopic tests at the anchor, the widely used magnetic method gives unreliable results, and therefore presents a problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enable increased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  9. Predictive validity of common mental disorders screening questionnaire as a screening instrument in long sickness absence

    DEFF Research Database (Denmark)

    Søgaard, Hans Jørgen; Bech, Per

    2010-01-01

    AIMS: Screening instruments for detection of common mental disorders have not been validity tested in long term sickness absence (LSA), which is the aim of this study for the Common Mental Disorders Screening Questionnaire (CMD-SQ). METHODS: Of all 2,414 incident persons on continuous sick...... in Denmark there is not a legal requirement that sick-listed persons are certified as sick by a physician....

  10. Test of a method for phase retrieval in HRTEM

    International Nuclear Information System (INIS)

    Beeching, M.J.; Spargo, A.E.C.

    1992-01-01

    Several methods of phase retrieval from the high resolution transmission electron microscopy image intensity distributions have been proposed but no standard method has emerged. The results achieved using a technique based on a development of the focus variation method, are reported. The dependence of the retrieved wavefunction on various experimental parameters is investigated and the method tested using computer simulated images. The method is shown to be useful in finding the complex wavefield at the exit surface of the specimen but the relationship of this to the specimen structure is considered as a separate issue. 1 ref., 3 figs

  11. Research Article Comparing covariance matrices: random skewers method compared to the common principal components model

    Directory of Open Access Journals (Sweden)

    James M. Cheverud

    2007-03-01

    Full Text Available Comparisons of covariance patterns are becoming more common as interest in the evolution of relationships between traits and in the evolutionary phenotypic diversification of clades have grown. We present parallel analyses of covariance matrix similarity for cranial traits in 14 New World Monkey genera using the Random Skewers (RS, T-statistics, and Common Principal Components (CPC approaches. We find that the CPC approach is very powerful in that with adequate sample sizes, it can be used to detect significant differences in matrix structure, even between matrices that are virtually identical in their evolutionary properties, as indicated by the RS results. We suggest that in many instances the assumption that population covariance matrices are identical be rejected out of hand. The more interesting and relevant question is, How similar are two covariance matrices with respect to their predicted evolutionary responses? This issue is addressed by the random skewers method described here.

  12. Explaining Post-Communist Respect for Civil Liberty: A Multi-Methods Test

    DEFF Research Database (Denmark)

    Skaaning, Svend Erik

    2007-01-01

    This article explains the level of respect for civil liberty in post-communist countries. The methodological triangulation employs both QCA methods and OLS-regression to test the influence of structural conditions, the democratization literature emphasizes. The results show that the political leg...... the results of the methods applied diverge. Expect a lack of congruence given their different assumptions and logics. As to the QCA methods in specific, they are apparently valuable supplements, and at times even plausible alternatives, to standard statistical tests....

  13. Note on a simple test method for estimaing J/sub Ic/

    International Nuclear Information System (INIS)

    Whipple, T.A.; McHenry, H.I.

    1980-01-01

    Fracture toughness testing is generally a time-consuming and expensive procedure; therefore, there has been a significant amount of effort directed toward developing an inexpensive and rapid method of estimating the fracture toughness of materials. In this paper, a simple method for estimating J/sub Ic/ through the use of small, notched, bend bars is evaluated. The test only involves the measurement of the energy necessary to fracture the sample. Initial tests on Fe-18Cr-3Ni-13Mn and 304L stainless steel at 76 and 4 0 K have yielded results consistent with other fracture toughness tests, for materials in the low- to medium-toughness range

  14. The gastro-oesophageal common cavity revisited

    NARCIS (Netherlands)

    Aanen, M. C.; Bredenoord, A. J.; Samsom, M.; Smout, A. J. P. M.

    2006-01-01

    The manometric common cavity phenomenon has been used as indicator of gastro-oesophageal reflux of liquid or gaseous substances. Using combined pH and impedance recording as reference standard the value of a common cavity as indicator of gastro-oesophageal reflux was tested. Ten healthy male

  15. A powerful nonparametric method for detecting differentially co-expressed genes: distance correlation screening and edge-count test.

    Science.gov (United States)

    Zhang, Qingyang

    2018-05-16

    Differential co-expression analysis, as a complement of differential expression analysis, offers significant insights into the changes in molecular mechanism of different phenotypes. A prevailing approach to detecting differentially co-expressed genes is to compare Pearson's correlation coefficients in two phenotypes. However, due to the limitations of Pearson's correlation measure, this approach lacks the power to detect nonlinear changes in gene co-expression which is common in gene regulatory networks. In this work, a new nonparametric procedure is proposed to search differentially co-expressed gene pairs in different phenotypes from large-scale data. Our computational pipeline consisted of two main steps, a screening step and a testing step. The screening step is to reduce the search space by filtering out all the independent gene pairs using distance correlation measure. In the testing step, we compare the gene co-expression patterns in different phenotypes by a recently developed edge-count test. Both steps are distribution-free and targeting nonlinear relations. We illustrate the promise of the new approach by analyzing the Cancer Genome Atlas data and the METABRIC data for breast cancer subtypes. Compared with some existing methods, the new method is more powerful in detecting nonlinear type of differential co-expressions. The distance correlation screening can greatly improve computational efficiency, facilitating its application to large data sets.

  16. Research on Generating Method of Embedded Software Test Document Based on Dynamic Model

    Science.gov (United States)

    Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying

    2018-03-01

    This paper provides a dynamic model-based test document generation method for embedded software that provides automatic generation of two documents: test requirements specification documentation and configuration item test documentation. This method enables dynamic test requirements to be implemented in dynamic models, enabling dynamic test demand tracking to be easily generated; able to automatically generate standardized, standardized test requirements and test documentation, improved document-related content inconsistency and lack of integrity And other issues, improve the efficiency.

  17. 16 CFR 1509.6 - Component-spacing test method.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Component-spacing test method. 1509.6 Section 1509.6 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT... applied to the wedge perpendicular to the plane of the crib side. ...

  18. Uncertainties and quantification of common cause failure rates and probabilities for system analyses

    International Nuclear Information System (INIS)

    Vaurio, Jussi K.

    2005-01-01

    Simultaneous failures of multiple components due to common causes at random times are modelled by constant multiple-failure rates. A procedure is described for quantification of common cause failure (CCF) basic event probabilities for system models using plant-specific and multiple-plant failure-event data. Methodology is presented for estimating CCF-rates from event data contaminated with assessment uncertainties. Generalised impact vectors determine the moments for the rates of individual systems or plants. These moments determine the effective numbers of events and observation times to be input to a Bayesian formalism to obtain plant-specific posterior CCF-rates. The rates are used to determine plant-specific common cause event probabilities for the basic events of explicit fault tree models depending on test intervals, test schedules and repair policies. Three methods are presented to determine these probabilities such that the correct time-average system unavailability can be obtained with single fault tree quantification. Recommended numerical values are given and examples illustrate different aspects of the methodology

  19. Test–Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Clare E. Palmer

    2018-01-01

    Full Text Available Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington’s disease (HD and Parkinson’s disease (PD across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test–retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test–retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test–retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT from the combined-Simon-Stop-Signal task showed moderate test–retest reliability, however, the combined SSRT interference effect showed poor test–retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  20. Verification methods for treaties limiting and banning nuclear tests

    International Nuclear Information System (INIS)

    Voloshin, N.P.

    1998-01-01

    Treaty on limitation of underground nuclear weapon tests and treaty on world banning of nuclear tests contribute to and accompany the process of nuclear disarmament. Test ban in three (Moscow treaty of 1963) as well as the Threshold Test Ban up to 1991 was controlled only with national means. But since 1991 nuclear test threshold of 150 kt has been measured with hydrodynamic and tele seismic methods and checked by the inspection. Distinctive feature of this control is that control is that it is bilateral. This conforms to Treaty on limitation of underground nuclear weapon tests signed by two countries - USA and USSR. The inspection at the place of tests requires monitoring of the test site of the party conducting a test and geological information of rock in the area of explosion. In the treaty of the World Nuclear Test Ban the following ways of international control are provided for: - seismologic measurements; - radionuclide measurements; - hydro-acoustics measurements; - infra-sound measurements; - inspection at the place of the tests conduction