WorldWideScience

Sample records for commercial building interfaced

  1. Commercial Buildings Characteristics, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-29

    Commercial Buildings Characteristics 1992 presents statistics about the number, type, and size of commercial buildings in the United States as well as their energy-related characteristics. These data are collected in the Commercial Buildings Energy Consumption Survey (CBECS), a national survey of buildings in the commercial sector. The 1992 CBECS is the fifth in a series conducted since 1979 by the Energy Information Administration. Approximately 6,600 commercial buildings were surveyed, representing the characteristics and energy consumption of 4.8 million commercial buildings and 67.9 billion square feet of commercial floorspace nationwide. Overall, the amount of commercial floorspace in the United States increased an average of 2.4 percent annually between 1989 and 1992, while the number of commercial buildings increased an average of 2.0 percent annually.

  2. Commercial Buildings Energy Performance within Context

    DEFF Research Database (Denmark)

    Lazarova-Molnar, Sanja; Kjærgaard, Mikkel Baun; Shaker, Hamid Reza

    2015-01-01

    Existing commercial buildings represent a challenge in the energy efficiency domain. Energy efficiency of a building, very often equalized to a building’s performance should not be observed as a standalone issue. For commercial buildings, energy efficiency needs to be observed and assessed within...

  3. Green commercial building insurance in Malaysia

    Science.gov (United States)

    Yang, Yu Xin Ou; Chew, Boon Cheong; Loo, Heoy Shin; Tan, Lay Hong

    2017-03-01

    Green building construction is growing tremendously globally even in Malaysia. Currently, there are approximate 636 buildings have registered and to be certified with Green Building Index. Among these buildings, 45 buildings have already fulfilled the requirements and fully certified. The other buildings still under provisional certification stage. Malaysia had adopted Green Building Index in 2009 to support a move to promote green building concept. Malaysia starts to move towards green building because Malaysian construction and building industry realizes that both energy consumed and waste produced are reduced without irreversible impacts to ecosystems. Consequently, insurance companies such as Fireman's Fund from America has started the green building insurance policies for their green building in the year of 2006, while Malaysia still remain the coverage for green buildings using conventional property insurance. There are lacks of efforts to be seen from insurance companies to propose green building insurance for these green buildings. There are a few factors which can take into consideration for insurance companies to start the very first green building insurance in Malaysia. Although there are challenges, some efficient strategies have been identified to overcome the problems. The methods used in this research topic is qualitative research. The results obtained shows that green commercial building insurance has a huge business opportunity in Malaysia because the number of green commercial buildings are increasing tremendously in Malaysia. It is a favor to implement green building insurance in Malaysia. Furthermore, insurance companies can consider to add in extra coverage in standard building policy to provide extra protection for non-certified green buildings which have the intention to rebuilt in green when damage happens. Generally, it is very important to introduce green commercial buildings insurance into Malaysia so that all of the green commercial

  4. Commercial Building Energy Asset Score

    Energy Technology Data Exchange (ETDEWEB)

    2017-05-26

    This software (Asset Scoring Tool) is designed to help building owners and managers to gain insight into the as-built efficiency of their buildings. It is a web tool where users can enter their building information and obtain an asset score report. The asset score report consists of modeled building energy use (by end use and by fuel type), building systems (envelope, lighting, heating, cooling, service hot water) evaluations, and recommended energy efficiency measures. The intended users are building owners and operators who have limited knowledge of building energy efficiency. The scoring tool collects minimum building data (~20 data entries) from users and build a full-scale energy model using the inference functionalities from Facility Energy Decision System (FEDS). The scoring tool runs real-time building energy simulation using EnergyPlus and performs life-cycle cost analysis using FEDS. An API is also under development to allow the third-party applications to exchange data with the web service of the scoring tool.

  5. Project materials [Commercial High Performance Buildings Project

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-01-01

    The Consortium for High Performance Buildings (ChiPB) is an outgrowth of DOE'S Commercial Whole Buildings Roadmapping initiatives. It is a team-driven public/private partnership that seeks to enable and demonstrate the benefit of buildings that are designed, built and operated to be energy efficient, environmentally sustainable, superior quality, and cost effective.

  6. Automated Continuous Commissioning of Commercial Buildings

    Science.gov (United States)

    2011-09-01

    Acronyms AHU: Air Handling Unit ANSI: American National Standards Institute API: Application Programming Interface ASHRAE : American Society of Heating... Refrigerating , and Air-Conditioning Engineers BACnet: Building Automation and Control Networks BMS: Building Management System CFM: Cubic Feet per Minute...from the database, performs computations, and archives the results back in the database. The visualization module is implemented as a stand The user

  7. Commercial Buildings High Performance Rooftop Unit Challenge

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-12-16

    The U.S. Department of Energy (DOE) and the Commercial Building Energy Alliances (CBEAs) are releasing a new design specification for high performance rooftop air conditioning units (RTUs). Manufacturers who develop RTUs based on this new specification will find strong interest from the commercial sector due to the energy and financial savings.

  8. Commercial Building Partnership General Merchandise Energy Savings Overview

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    The Commercial Building Partnership (CBP) paired selected commercial building owners and operators with representatives of DOE, national laboratories and private sector exports to explore energy efficiency measures across general merchandise commercial buildings.

  9. Commercial Building Partnership Retail Food Sales Energy Savings Overview

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    The Commercial Building Partnership (CBP) paired selected commercial building owners and operators with representatives of DOE, national laboratories and private sector exports to explore energy efficiency measures across general merchandise commercial buildings.

  10. Characterization of commercial building appliances. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.F.; Teagan, P.W.; Dieckmann, J.T.

    1993-08-01

    This study focuses on ``other`` end-uses category. The purpose of this study was to determine the relative importance of energy end-use functions other than HVAC and lighting for commercial buildings, and to identify general avenues and approaches for energy use reduction. Specific energy consuming technologies addressed include non-HVAC and lighting technologies in commercial buildings with significant energy use to warrant detailed analyses. The end-uses include office equipment, refrigeration, water heating, cooking, vending machines, water coolers, laundry equipment and electronics other than office equipment. The building types include offices, retail, restaurants, schools, hospitals, hotels/motels, grocery stores, and warehouses.

  11. High-performance commercial building systems

    Energy Technology Data Exchange (ETDEWEB)

    Selkowitz, Stephen

    2003-10-01

    This report summarizes key technical accomplishments resulting from the three year PIER-funded R&D program, ''High Performance Commercial Building Systems'' (HPCBS). The program targets the commercial building sector in California, an end-use sector that accounts for about one-third of all California electricity consumption and an even larger fraction of peak demand, at a cost of over $10B/year. Commercial buildings also have a major impact on occupant health, comfort and productivity. Building design and operations practices that influence energy use are deeply engrained in a fragmented, risk-averse industry that is slow to change. Although California's aggressive standards efforts have resulted in new buildings designed to use less energy than those constructed 20 years ago, the actual savings realized are still well below technical and economic potentials. The broad goal of this program is to develop and deploy a set of energy-saving technologies, strategies, and techniques, and improve processes for designing, commissioning, and operating commercial buildings, while improving health, comfort, and performance of occupants, all in a manner consistent with sound economic investment practices. Results are to be broadly applicable to the commercial sector for different building sizes and types, e.g. offices and schools, for different classes of ownership, both public and private, and for owner-occupied as well as speculative buildings. The program aims to facilitate significant electricity use savings in the California commercial sector by 2015, while assuring that these savings are affordable and promote high quality indoor environments. The five linked technical program elements contain 14 projects with 41 distinct R&D tasks. Collectively they form a comprehensive Research, Development, and Demonstration (RD&D) program with the potential to capture large savings in the commercial building sector, providing significant economic benefits to

  12. Energy Efficiency Building Code for Commercial Buildings in Sri Lanka

    Energy Technology Data Exchange (ETDEWEB)

    Busch, John; Greenberg, Steve; Rubinstein, Francis; Denver, Andrea; Rawner, Esther; Franconi, Ellen; Huang, Joe; Neils, Danielle

    2000-09-30

    1.1.1 To encourage energy efficient design or retrofit of commercial buildings so that they may be constructed, operated, and maintained in a manner that reduces the use of energy without constraining the building function, the comfort, health, or the productivity of the occupants and with appropriate regard for economic considerations. 1.1.2 To provide criterion and minimum standards for energy efficiency in the design or retrofit of commercial buildings and provide methods for determining compliance with them. 1.1.3 To encourage energy efficient designs that exceed these criterion and minimum standards.

  13. Commercial Building Partnerships Replication and Diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Antonopoulos, Chrissi A.; Dillon, Heather E.; Baechler, Michael C.

    2013-09-16

    This study presents findings from survey and interview data investigating replication efforts of Commercial Building Partnership (CBP) partners that worked directly with the Pacific Northwest National Laboratory (PNNL). PNNL partnered directly with 12 organizations on new and retrofit construction projects, which represented approximately 28 percent of the entire U.S. Department of Energy (DOE) CBP program. Through a feedback survey mechanism, along with personal interviews, PNNL gathered quantitative and qualitative data relating to replication efforts by each organization. These data were analyzed to provide insight into two primary research areas: 1) CBP partners’ replication efforts of technologies and approaches used in the CBP project to the rest of the organization’s building portfolio (including replication verification), and, 2) the market potential for technology diffusion into the total U.S. commercial building stock, as a direct result of the CBP program. The first area of this research focused specifically on replication efforts underway or planned by each CBP program participant. Factors that impact replication include motivation, organizational structure and objectives firms have for implementation of energy efficient technologies. Comparing these factors between different CBP partners revealed patterns in motivation for constructing energy efficient buildings, along with better insight into market trends for green building practices. The second area of this research develops a diffusion of innovations model to analyze potential broad market impacts of the CBP program on the commercial building industry in the United States.

  14. High-performance commercial building systems

    Energy Technology Data Exchange (ETDEWEB)

    Selkowitz, Stephen

    2003-10-01

    This report summarizes key technical accomplishments resulting from the three year PIER-funded R&D program, ''High Performance Commercial Building Systems'' (HPCBS). The program targets the commercial building sector in California, an end-use sector that accounts for about one-third of all California electricity consumption and an even larger fraction of peak demand, at a cost of over $10B/year. Commercial buildings also have a major impact on occupant health, comfort and productivity. Building design and operations practices that influence energy use are deeply engrained in a fragmented, risk-averse industry that is slow to change. Although California's aggressive standards efforts have resulted in new buildings designed to use less energy than those constructed 20 years ago, the actual savings realized are still well below technical and economic potentials. The broad goal of this program is to develop and deploy a set of energy-saving technologies, strategies, and techniques, and improve processes for designing, commissioning, and operating commercial buildings, while improving health, comfort, and performance of occupants, all in a manner consistent with sound economic investment practices. Results are to be broadly applicable to the commercial sector for different building sizes and types, e.g. offices and schools, for different classes of ownership, both public and private, and for owner-occupied as well as speculative buildings. The program aims to facilitate significant electricity use savings in the California commercial sector by 2015, while assuring that these savings are affordable and promote high quality indoor environments. The five linked technical program elements contain 14 projects with 41 distinct R&D tasks. Collectively they form a comprehensive Research, Development, and Demonstration (RD&D) program with the potential to capture large savings in the commercial building sector, providing significant economic benefits to

  15. Integrated urban water management in commercial buildings.

    Science.gov (United States)

    Trowsdale, S; Gabe, J; Vale, R

    2011-01-01

    Monitoring results are presented as an annual water balance from the pioneering Landcare Research green building containing commercial laboratory and office space. The building makes use of harvested roof runoff to flush toilets and urinals and irrigate glasshouse experiments, reducing the demand for city-supplied water and stormwater runoff. Stormwater treatment devices also manage the runoff from the carpark, helping curb stream degradation. Composting toilets and low-flow tap fittings further reduce the water demand. Despite research activities requiring the use of large volumes of water, the demand for city-supplied water is less than has been measured in many other green buildings. In line with the principles of sustainability, the composting toilets produce a useable product from wastes and internalise the wastewater treatment process.

  16. Diffusion of Energy Efficient Technology in Commercial Buildings: An Analysis of the Commercial Building Partnerships Program

    Science.gov (United States)

    Antonopoulos, Chrissi Argyro

    This study presents findings from survey and interview data investigating replication of green building measures by Commercial Building Partnership (CBP) partners that worked directly with the Pacific Northwest National Laboratory (PNNL). PNNL partnered directly with 12 organizations on new and retrofit construction projects, which represented approximately 28 percent of the entire U.S. Department of Energy (DOE) CBP program. Through a feedback survey mechanism, along with personal interviews, quantitative and qualitative data were gathered relating to replication efforts by each organization. These data were analyzed to provide insight into two primary research areas: 1) CBP partners' replication efforts of green building approaches used in the CBP project to the rest of the organization's building portfolio, and, 2) the market potential for technology diffusion into the total U.S. commercial building stock, as a direct result of the CBP program. The first area of this research focused specifically on replication efforts underway or planned by each CBP program participant. The second area of this research develops a diffusion of innovations model to analyze potential broad market impacts of the CBP program on the commercial building industry in the United States. Findings from this study provided insight into motivations and objectives CBP partners had for program participation. Factors that impact replication include motivation, organizational structure and objectives firms have for implementation of energy efficient technologies. Comparing these factors between different CBP partners revealed patterns in motivation for constructing energy efficient buildings, along with better insight into market trends for green building practices. The optimized approach to the CBP program allows partners to develop green building parameters that fit the specific uses of their building, resulting in greater motivation for replication. In addition, the diffusion model developed

  17. Energy simulation and optimization for a small commercial building through Modelica

    Science.gov (United States)

    Rivas, Bryan

    Small commercial buildings make up the majority of buildings in the United States. Energy consumed by these buildings is expected to drastically increase in the next few decades, with a large percentage of the energy consumed attributed to cooling systems. This work presents the simulation and optimization of a thermostat schedule to minimize energy consumption in a small commercial building test bed during the cooling season. The simulation occurs through the use of the multi-engineering domain Dymola environment based on the Modelica open source programming language and is optimized with the Java based optimization program GenOpt. The simulation uses both physically based modeling utilizing heat transfer principles for the building and regression analysis for energy consumption. GenOpt is dynamically coupled to Dymola through various interface files. There are very few studies that have coupled GenOpt to a building simulation program and even fewer studies have used Dymola for building simulation as extensively as the work presented here. The work presented proves Dymola as a viable alternative to other building simulation programs such as EnergyPlus and MatLab. The model developed is used to simulate the energy consumption of a test bed, a commissioned real world small commercial building, while maintaining indoor thermal comfort. Potential applications include smart or intelligent building systems, predictive simulation of small commercial buildings, and building diagnostics.

  18. Universal Library for Building Radar Operator Interface

    Directory of Open Access Journals (Sweden)

    A. A. Karankevich

    2014-01-01

    Full Text Available The article contains the results of the development of a software library, used for building software interfaces for radars being developed in BMSTU Radioelectronic Technics Scientific and Research Institute. The library is a software application library written in C++ using Qt and OpenGL libraries.The article describes the requirements, that the library is supposed to meet, in particular — cross-platform capabilities and versatility of the solution. The data types, that library uses, are described. The description of theinterface elements developed is shown, and some pictures of their operation are given.The article shows the main interface elements used. They are: «Matrix» that shows twodimensional data, «Waterfall», that is used for time scanning of the parameter specified, and «Plan Position Indicator» that shows circular scan from surveillance radar without geometric distortions.The part «Library implementation» shows the example of radiolocation station interface, that was based on this library, used in the working model of ultrashortpulse radar. Some results of the operation of this interface are also shown. The experiment shows the system working with two people in the field. As people start to move, the system becomes capable of distinguishing moving targets and stationary surface. The article shows the system operation the same way as the system operator can see it through his interface.The conclusion contains brief results of the development, the sphere of application of the software, and the prospects of the further development of the library.

  19. U.S. Department of Energy Commercial Reference Building Models of the National Building Stock

    Energy Technology Data Exchange (ETDEWEB)

    Deru, M.; Field, K.; Studer, D.; Benne, K.; Griffith, B.; Torcellini, P.; Liu, B.; Halverson, M.; Winiarski, D.; Rosenberg, M.; Yazdanian, M.; Huang, J.; Crawley, D.

    2011-02-01

    The U.S. Department of Energy (DOE) Building Technologies Program has set the aggressive goal of producing marketable net-zero energy buildings by 2025. This goal will require collaboration between the DOE laboratories and the building industry. We developed standard or reference energy models for the most common commercial buildings to serve as starting points for energy efficiency research. These models represent fairly realistic buildings and typical construction practices. Fifteen commercial building types and one multifamily residential building were determined by consensus between DOE, the National Renewable Energy Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory, and represent approximately two-thirds of the commercial building stock.

  20. Development of a California commercial building benchmarking database

    Energy Technology Data Exchange (ETDEWEB)

    Kinney, Satkartar; Piette, Mary Ann

    2002-05-17

    Building energy benchmarking is a useful starting point for commercial building owners and operators to target energy savings opportunities. There are a number of tools and methods for benchmarking energy use. Benchmarking based on regional data can provides more relevant information for California buildings than national tools such as Energy Star. This paper discusses issues related to benchmarking commercial building energy use and the development of Cal-Arch, a building energy benchmarking database for California. Currently Cal-Arch uses existing survey data from California's Commercial End Use Survey (CEUS), a largely underutilized wealth of information collected by California's major utilities. Doe's Commercial Building Energy Consumption Survey (CBECS) is used by a similar tool, Arch, and by a number of other benchmarking tools. Future versions of Arch/Cal-Arch will utilize additional data sources including modeled data and individual buildings to expand the database.

  1. Methodology for Modeling Building Energy Performance across the Commercial Sector

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.; Long, N.; Torcellini, P.; Judkoff, R.; Crawley, D.; Ryan, J.

    2008-03-01

    This report uses EnergyPlus simulations of each building in the 2003 Commercial Buildings Energy Consumption Survey (CBECS) to document and demonstrate bottom-up methods of modeling the entire U.S. commercial buildings sector (EIA 2006). The ability to use a whole-building simulation tool to model the entire sector is of interest because the energy models enable us to answer subsequent 'what-if' questions that involve technologies and practices related to energy. This report documents how the whole-building models were generated from the building characteristics in 2003 CBECS and compares the simulation results to the survey data for energy use.

  2. Industry Research and Recommendations for New Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, B.; Leach, M.; Gregory, N.; Pless, S.; Selkowitz, S.; Matthew, P.

    2014-05-01

    Researchers evaluated industry needs and developed logic models to support possible future commercial new construction research and deployment efforts that could be led or supported by DOE's Commercial Building Integration program or other national initiatives. The authors believe that these recommendations support a proposed course of action from the current state of commercial building energy efficiency to a possible long-term goal of achieving significant market penetration of cost-effective NZE buildings in all building sectors and climates by 2030.

  3. Software-Defined Solutions for Managing Energy Use in Small to Medium Sized Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Peffer, Therese [Univ. of California, Berkeley, CA (United States); Council on International Education Exchange (CIEE), Portland, ME (United States); Blumstein, Carl [Council on International Education Exchange (CIEE), Portland, ME (United States); Culler, David [Univ. of California, Berkeley, CA (United States). Electrical Engineering and Computer Sciences (EECS); Modera, Mark [Univ. of California, Davis, CA (United States). Western Cooling Efficiency Center (WCEC); Meier, Alan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-09-10

    The Project uses state-of-the-art computer science to extend the benefits of Building Automation Systems (BAS) typically found in large buildings (>100,000 square foot) to medium-sized commercial buildings (<50,000 sq ft). The BAS developed in this project, termed OpenBAS, uses an open-source and open software architecture platform, user interface, and plug-and-play control devices to facilitate adoption of energy efficiency strategies in the commercial building sector throughout the United States. At the heart of this “turn key” BAS is the platform with three types of controllers—thermostat, lighting controller, and general controller—that are easily “discovered” by the platform in a plug-and-play fashion. The user interface showcases the platform and provides the control system set-up, system status display and means of automatically mapping the control points in the system.

  4. Building as Interface: Sustainable Educational Ecologies

    Directory of Open Access Journals (Sweden)

    Suzanne de Castell

    2014-09-01

    Full Text Available This paper begins with the most obvious, and yet most elusive, of educational media ecologies, the buildings which are ‹home› to pedagogic communication and interaction, and considers how we might understand «building as interface», construed first as a noun, («a structure with roof and walls» – OED referring to places as physical structures, and then as a verb, («the action or trade of constructing something» – OED, referring to the activities of construction through which we can engage technologies central to theory, research and practice. Our concern is with exploring the larger question of educational sustainability: with what ‹sustainability› means when applied to a specifically educational context, and with the sustainability of the kinds of emerging educational environments in which new information and communications technologies play a significant role. This question of sustainable educational environments is driven by a need to be responsible and accountable for the impact of the technologies and practices we eagerly embrace in the name of «21st century learning», even as prospects for a 22nd century are so rapidly receding from view. As one prominent media ecologist put the point: «we have to find the environments in which it will be possible to live with our new inventions» (McLuhan 1967, 124.

  5. A Retrofit Tool for Improving Energy Efficiency of Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Levine, Mark; Feng, Wei; Ke, Jing; Hong, Tianzhen; Zhou, Nan

    2013-06-06

    Existing buildings will dominate energy use in commercial buildings in the United States for three decades or longer and even in China for the about two decades. Retrofitting these buildings to improve energy efficiency and reduce energy use is thus critical to achieving the target of reducing energy use in the buildings sector. However there are few evaluation tools that can quickly identify and evaluate energy savings and cost effectiveness of energy conservation measures (ECMs) for retrofits, especially for buildings in China. This paper discusses methods used to develop such a tool and demonstrates an application of the tool for a retrofit analysis. The tool builds on a building performance database with pre-calculated energy consumption of ECMs for selected commercial prototype buildings using the EnergyPlus program. The tool allows users to evaluate individual ECMs or a package of ECMs. It covers building envelope, lighting and daylighting, HVAC, plug loads, service hot water, and renewable energy. The prototype building can be customized to represent an actual building with some limitations. Energy consumption from utility bills can be entered into the tool to compare and calibrate the energy use of the prototype building. The tool currently can evaluate energy savings and payback of ECMs for shopping malls in China. We have used the tool to assess energy and cost savings for retrofit of the prototype shopping mall in Shanghai. Future work on the tool will simplify its use and expand it to cover other commercial building types and other countries.

  6. Energy end-use intensities in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    This report examines energy intensities in commercial buildings for nine end uses: space heating, cooling, ventilation, lighting, water heating, cooking, refrigeration, office equipment, and other. The objective of this analysis was to increase understanding of how energy is used in commercial buildings and to identify targets for greater energy efficiency which could moderate future growth in demand. The source of data for the analysis is the 1989 Commercial Buildings Energy Consumption survey (CBECS), which collected detailed data on energy-related characteristics and energy consumption for a nationally representative sample of approximately 6,000 commercial buildings. The analysis used 1989 CBECS data because the 1992 CBECS data were not yet available at the time the study was initiated. The CBECS data were fed into the Facility Energy Decision Screening (FEDS) system, a building energy simulation program developed by the US Department of Energy`s Pacific Northwest Laboratory, to derive engineering estimates of end-use consumption for each building in the sample. The FEDS estimates were then statistically adjusted to match the total energy consumption for each building. This is the Energy Information Administration`s (EIA) first report on energy end-use consumption in commercial buildings. This report is part of an effort to address customer requests for more information on how energy is used in buildings, which was an overall theme of the 1992 user needs study. The end-use data presented in this report were not available for publication in Commercial Buildings Energy Consumption and Expenditures 1989 (DOE/EIA-0318(89), Washington, DC, April 1992). However, subsequent reports on end-use energy consumption will be part of the Commercial Buildings Energy Consumption and Expenditures series, beginning with a 1992 data report to be published in early 1995.

  7. Recovery Act: Training Program Development for Commercial Building Equipment Technicians

    Energy Technology Data Exchange (ETDEWEB)

    Leah Glameyer

    2012-07-12

    The overall goal of this project has been to develop curricula, certification requirements, and accreditation standards for training on energy efficient practices and technologies for commercial building technicians. These training products will advance industry expertise towards net-zero energy commercial building goals and will result in a substantial reduction in energy use. The ultimate objective is to develop a workforce that can bring existing commercial buildings up to their energy performance potential and ensure that new commercial buildings do not fall below their expected optimal level of performance. Commercial building equipment technicians participating in this training program will learn how to best operate commercial buildings to ensure they reach their expected energy performance level. The training is a combination of classroom, online and on-site lessons. The Texas Engineering Extension Service (TEEX) developed curricula using subject matter and adult learning experts to ensure the training meets certification requirements and accreditation standards for training these technicians. The training targets a specific climate zone to meets the needs, specialized expertise, and perspectives of the commercial building equipment technicians in that zone. The combination of efficient operations and advanced design will improve the internal built environment of a commercial building by increasing comfort and safety, while reducing energy use and environmental impact. Properly trained technicians will ensure equipment operates at design specifications. A second impact is a more highly trained workforce that is better equipped to obtain employment. Organizations that contributed to the development of the training program include TEEX and the Texas Engineering Experiment Station (TEES) (both members of The Texas A&M University System). TEES is also a member of the Building Commissioning Association. This report includes a description of the project

  8. Residential and commercial buildings data book: Third edition

    Energy Technology Data Exchange (ETDEWEB)

    Amols, G.R.; Howard, K.B.; Nicholls, A.K.; Guerra, T.D.

    1988-02-01

    This Data Book updates and expands the previous Data Book originally published by the Department of Energy in September, 1986 (DOE/RL/01830/16). Energy-related information is provided under the following headings: Characteristics of Residential Buildings in the US; Characteristics of New Single Family Construction in the US; Characteristics of New Multi-Family Construction in the US; Household Appliances; Residential Sector Energy Consumption, Prices, and Expenditures; Characteristics of US Commercial Buildings; Commercial Buildings Energy Consumption, Prices, and Expenditures; and Additional Buildings and Community Systems Information. 12 refs., 59 figs., 118 tabs.

  9. Energy Efficiency, Building Productivity and the Commercial Buildings Market

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.W.

    2002-05-16

    The energy-efficiency gap literature suggests that building buyers are often short-sighted in their failure to apply life-cycle costing principles to energy efficient building technologies, with the result that under investment in these advanced technology occurs. This study examines the reasons this behavior may occur, by analyzing the pressures that market forces place on purchasers of buildings. Our basic conclusion is that the fundamental manner in which the buildings sector does business creates pressures to reduce initial capital outlays and to hedge against a variety of risks, including the ability of building owners to capture benefits from energy efficiency. Starting from the position that building buyers' willingness to pay drives choices over building attributes, we examine basic market principles, the structure of the buildings market, including the role of lenders, and policies that promote penetration of energy efficient technologies. We conclude that greater attention to buyers, and to the incentives and constraints they face, would promote a better understanding of building investment choices and contribute to better policies to promote the penetration of these technologies into markets.

  10. The Role of Energy Storage in Commercial Building

    Energy Technology Data Exchange (ETDEWEB)

    Kintner-Meyer, Michael CW; Subbarao, Krishnappa; Prakash Kumar, Nirupama; Bandyopadhyay, Gopal K.; Finley, C.; Koritarov, V. S.; Molburg, J. C.; Wang, J.; Zhao, Fuli; Brackney, L.; Florita, A. R.

    2010-09-30

    Motivation and Background of Study This project was motivated by the need to understand the full value of energy storage (thermal and electric energy storage) in commercial buildings, the opportunity of benefits for building operations and the potential interactions between a building and a smart grid infrastructure. On-site or local energy storage systems are not new to the commercial building sector; they have been in place in US buildings for decades. Most building-scale storage technologies are based on thermal or electrochemical storage mechanisms. Energy storage technologies are not designed to conserve energy, and losses associated with energy conversion are inevitable. Instead, storage provides flexibility to manage load in a building or to balance load and generation in the power grid. From the building owner's perspective, storage enables load shifting to optimize energy costs while maintaining comfort. From a grid operations perspective, building storage at scale could provide additional flexibility to grid operators in managing the generation variability from intermittent renewable energy resources (wind and solar). To characterize the set of benefits, technical opportunities and challenges, and potential economic values of storage in a commercial building from both the building operation's and the grid operation's view-points is the key point of this project. The research effort was initiated in early 2010 involving Argonne National Laboratory (ANL), the National Renewable Energy Laboratory (NREL), and Pacific Northwest National Laboratory (PNNL) to quantify these opportunities from a commercial buildings perspective. This report summarizes the early discussions, literature reviews, stakeholder engagements, and initial results of analyses related to the overall role of energy storage in commercial buildings. Beyond the summary of roughly eight months of effort by the laboratories, the report attempts to substantiate the importance of

  11. High-performance commercial building facades

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor; Selkowitz, Stephen; Bazjanac, Vladimir; Inkarojrit, Vorapat; Kohler, Christian

    2002-06-01

    This study focuses on advanced building facades that use daylighting, sun control, ventilation systems, and dynamic systems. A quick perusal of the leading architectural magazines, or a discussion in most architectural firms today will eventually lead to mention of some of the innovative new buildings that are being constructed with all-glass facades. Most of these buildings are appearing in Europe, although interestingly U.S. A/E firms often have a leading role in their design. This ''emerging technology'' of heavily glazed fagades is often associated with buildings whose design goals include energy efficiency, sustainability, and a ''green'' image. While there are a number of new books on the subject with impressive photos and drawings, there is little critical examination of the actual performance of such buildings, and a generally poor understanding as to whether they achieve their performance goals, or even what those goals might be. Even if the building ''works'' it is often dangerous to take a design solution from one climate and location and transport it to a new one without a good causal understanding of how the systems work. In addition, there is a wide range of existing and emerging glazing and fenestration technologies in use in these buildings, many of which break new ground with respect to innovative structural use of glass. It is unclear as to how well many of these designs would work as currently formulated in California locations dominated by intense sunlight and seismic events. Finally, the costs of these systems are higher than normal facades, but claims of energy and productivity savings are used to justify some of them. Once again these claims, while plausible, are largely unsupported. There have been major advances in glazing and facade technology over the past 30 years and we expect to see continued innovation and product development. It is critical in this process to be able to

  12. Overview of Commercial Building Partnerships in Higher Education

    Energy Technology Data Exchange (ETDEWEB)

    Schatz, Glenn [Energy Efficiency and Renewable Energy (EERE), Washington, DC (United States)

    2013-03-01

    Higher education uses less energy per square foot than most commercial building sectors. However, higher education campuses house energy-intensive laboratories and data centers that may spend more than this average; laboratories, in particular, are disproportionately represented in the higher education sector. The Commercial Building Partnership (CBP), a public/private, cost-shared program sponsored by the U.S. Department of Energy (DOE), paired selected commercial building owners and operators with representatives of DOE, its national laboratories, and private-sector technical experts. These teams explored energy-saving measures across building systems–including some considered too costly or technologically challenging–and used advanced energy modeling to achieve peak whole-building performance. Modeling results were then included in new construction or retrofit designs to achieve significant energy reductions.

  13. Transactive Control of Commercial Buildings for Demand Response

    Energy Technology Data Exchange (ETDEWEB)

    Hao, He; Corbin, Charles D.; Kalsi, Karanjit; Pratt, Robert G.

    2017-01-01

    Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Several case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.

  14. Duct thermal performance models for large commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.

    2003-10-01

    Despite the potential for significant energy savings by reducing duct leakage or other thermal losses from duct systems in large commercial buildings, California Title 24 has no provisions to credit energy-efficient duct systems in these buildings. A substantial reason is the lack of readily available simulation tools to demonstrate the energy-saving benefits associated with efficient duct systems in large commercial buildings. The overall goal of the Efficient Distribution Systems (EDS) project within the PIER High Performance Commercial Building Systems Program is to bridge the gaps in current duct thermal performance modeling capabilities, and to expand our understanding of duct thermal performance in California large commercial buildings. As steps toward this goal, our strategy in the EDS project involves two parts: (1) developing a whole-building energy simulation approach for analyzing duct thermal performance in large commercial buildings, and (2) using the tool to identify the energy impacts of duct leakage in California large commercial buildings, in support of future recommendations to address duct performance in the Title 24 Energy Efficiency Standards for Nonresidential Buildings. The specific technical objectives for the EDS project were to: (1) Identify a near-term whole-building energy simulation approach that can be used in the impacts analysis task of this project (see Objective 3), with little or no modification. A secondary objective is to recommend how to proceed with long-term development of an improved compliance tool for Title 24 that addresses duct thermal performance. (2) Develop an Alternative Calculation Method (ACM) change proposal to include a new metric for thermal distribution system efficiency in the reporting requirements for the 2005 Title 24 Standards. The metric will facilitate future comparisons of different system types using a common ''yardstick''. (3) Using the selected near-term simulation approach

  15. Energy consumption in commercial buildings: A comparison with BEPS budgets

    Science.gov (United States)

    1980-09-01

    Metered energy consumption data were collected on existing commercial buildings to help establish the proposed building energy performance standards (BEPS). The search has identified 84 buildings whose metered energy consumption is equal to or less than that proposed for their BEPS budgets and another 7 buildings whose metered consumption is less than 20 percent above their BEPS budgets. The methodology used to identify the buildings and to collect their metered energy consumption data are described. The data are analyzed and summarized and conclusions are drawn.

  16. Predictive Solar-Integrated Commercial Building Load Control

    Energy Technology Data Exchange (ETDEWEB)

    Glasgow, Nathan [EdgePower Inc., Aspen, CO (United States)

    2017-01-31

    This report is the final technical report for the Department of Energy SunShot award number EE0007180 to EdgePower Inc., for the project entitled “Predictive Solar-Integrated Commercial Building Load Control.” The goal of this project was to successfully prove that the integration of solar forecasting and building load control can reduce demand charge costs for commercial building owners with solar PV. This proof of concept Tier 0 project demonstrated its value through a pilot project at a commercial building. This final report contains a summary of the work completed through he duration of the project. Clean Power Research was a sub-recipient on the award.

  17. Commercial building energy use monitoring for utility load research

    Energy Technology Data Exchange (ETDEWEB)

    Mazzucchi, R.P.

    1987-01-01

    This paper describes a method to acquire empirical data regarding commercial building energy performance for utility load research. The method was devised and implemented for a large scale monitoring program being conducted for a federal electricity marketing and transmission agency in the Pacific Northwest states. An important feature of this method is its hierarchical approach, wherein building types, end-use loads, and key building characteristics are classified to accommodate analysis at many levels. Through this common taxonomy and measurement protocol, energy-use metering projects of varying detail and comprehensiveness can be coordinated. The procedures devised for this project have been implemented for approximately 150 buildings to date by specially trained contractors. Hence, this paper provides real-world insights of the complexity and power of end use measurements from commercial buildings to address utility load research topics. 6 refs.

  18. On Building a Search Interface Discovery System

    Science.gov (United States)

    Shestakov, Denis

    A huge portion of the Web known as the deep Web is accessible via search interfaces to myriads of databases on the Web. While relatively good approaches for querying the contents of web databases have been recently proposed, one cannot fully utilize them having most search interfaces unlocated. Thus, the automatic recognition of search interfaces to online databases is crucial for any application accessing the deep Web. This paper describes the architecture of the I-Crawler, a system for finding and classifying search interfaces. The I-Crawler is intentionally designed to be used in the deep web characterization surveys and for constructing directories of deep web resources.

  19. New Construction for Commercial Building (Restaurant By Considering The Green Building Strategies

    Directory of Open Access Journals (Sweden)

    MF Baharom

    2015-08-01

    Full Text Available The Green Building Index (GBI is one of green building strategies that are needed in order to decrease the human technologies and waste made by them. Moreover, GBI is the latest green building strategies that been implemented in the new building construction in Malaysia. It is proven as the building sector consumes 40% of the total energy consumption in the world, thus increasing the environmental problems. Mechanical, cooling, lighting and ventilating spaces consume by far the most energy in buildings. Besides the energy consumption, the cost needed to develop the new building also been increased. This project sought to provide an understanding on the new construction of commercial building (restaurant which is selected with the objectives which to design all the electrical installation including the lighting system, air-conditioner, switch socket outlet (SSO, protection system, and cable selection in the commercial building (restaurant based on the Malaysia’s GBI, to analyze the lighting system by using DIALux software and all the connected electrical loads after implementing the GBI standards, and lastly to analyze the energy consumption as well as the cost in the new construction for commercial building (restaurant. The electrical installation and building design are done by using AutoCAD software whereas the lighting system is analyzed by using DIALux software. The load calculation, energy and cost consumption are been analyzed based on the GBI and electrical standards. Based on the results obtained, the overall energy and cost consumptions in the commercial building had been improved after implementing the green building strategies. The overall electrical installation in the building will be based on energy efficiency criteria of the GBI assessment criteria on the non-residential (commercial building which having the highest point. An electrical installation design, AutoCAD design, load calculation, energy and cost consumption are made

  20. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  1. Demographic and Commercial Environments and Building Control Customer Services

    Directory of Open Access Journals (Sweden)

    Hope Peter

    2016-01-01

    Full Text Available A simple and cost effective business analytics schema developed in this study provides a basis for observing how demographic and commercial environmental impacts affect building control customer services. In order to overlay environmental impacts onto building control services, schematic mapping of resource distributions and services were plotted according to corporate jurisdiction, corporate virtues and customer type characteristics. Quantitative and qualitative surveys were conducted on corporate staff and material resources, business performance measures and targets, building control service manager observations and demographic and commercial environments. Results from this research provide a single view corporate map of people, material resources, and service performance in relation to customer characteristics, while reaching out to better understand the building control customer experience, general public expectation and market influences. In this regard, this research can provide a foundation for realising corporate virtue aspirations.

  2. Analysis of institutional mechanisms affecting residential and commercial buildings retrofit

    Energy Technology Data Exchange (ETDEWEB)

    1980-09-01

    Barriers to energy conservation in the residential and commercial sectors influence (1) the willingness of building occupants to modify their energy usage habits, and (2) the willingness of building owners/occupants to upgrade the thermal characteristics of the structures within which they live or work and the appliances which they use. The barriers that influence the willingness of building owners/occupants to modify the thermal efficiency characteristics of building structures and heating/cooling systems are discussed. This focus is further narrowed to include only those barriers that impede modifications to existing buildings, i.e., energy conservation retrofit activity. Eight barriers selected for their suitability for Federal action in the residential and commercial sectors and examined are: fuel pricing policies that in the short term do not provide enough incentive to invest in energy conservation; high finance cost; inability to evaluate contractor performance; inability to evaluate retrofit products; lack of well-integrated or one-stop marketing systems (referred to as lack of delivery systems); lack of precise or customized information; lack of sociological/psychological incentives; and use of the first-cost decision criterion (expanded to include short-term payback criterion for the commercial sector). The impacts of these barriers on energy conservation are separately assessed for the residential and commercial sectors.

  3. A Concept-Centric Framework for Building Natural Language Interfaces

    Science.gov (United States)

    Funakoshi, Kotaro; Nakano, Mikio; Hasegawa, Yuji; Tsujino, Hiroshi

    Natural language interfaces are expected to come into practical use in many situations. It is, however, not practical to expect to achieve a universal interface because language use is so diverse. To that end, not only advancements in speech and language technologies but also well-designed development frameworks are required so that developers can build domain-specific interfaces rapidly and easily. This paper proposes KNOLU, a framework for building natural language interfaces of a broad range of applications. Developers using this framework can easily build an interface capable of understanding subsets of natural language expressions just by providing an ontology (a concept hierarchy with semantic frames and a lexicon), an onomasticon (a set of instances and their names) and API functions that provide procedural knowledge required to connect the interface to a target application. To develop an interface using KNOLU, first developers define a concept hierarchy for a target domain. Then they provide other declarative and procedural knowledge components with these knowledge components asscicated to the hierarchy. This developmental flow affords an unobstructed view both for development and maintanance. KNOLU uses an existing general-purpose parser and requires neither grammar rules nor expression patterns. It does not require rules to generate semantic interpretations from parsing results, either. Therefore, developers can build an interface without deep knowledge and experience of natural language processing. We applied KNOLU to two applications and confirmed the effectiveness.

  4. Development of a Training Program for Commercial Building Technicians

    Energy Technology Data Exchange (ETDEWEB)

    Rinholm, Rod

    2013-05-31

    This project focused on developing and deploying a comprehensive program of 22 training modules, including certification requirements, and accreditation standards for commercial building technicians, to help achieve the full savings potential of energy efficient buildings, equipment, and systems. This curriculum extended the currently available commercial building technician programs -- training a labor force in a growing market area focused on energy efficiency. The program helps to remove a major market impediment to low energy/zero energy commercial building system acceptance, namely a lack of operating personnel capable of handling more complex high efficiency systems. The project developed a training curriculum for commercial building technicians, with particular focus on high-efficiency building technology, and systems. In Phase 1, the project team worked collaboratively in developing a draft training syllabus to address project objectives. The team identified energy efficiency knowledge gaps in existing programs and plans and plans to address the gaps with either modified or new curricula. In Phase 2, appropriate training materials were developed to meet project objectives. This material was developed for alternative modes of delivery, including classroom lecture materials, e-learning elements, video segments, exercises, and hands-on training elements. A Certification and Accreditation Plan and a Commercialization and Sustainability Plan were also investigated and developed. The Project Management Plan was updated quarterly and provided direction on the management approaches used to accomplish the expected project objectives. GTI project management practices tightly coordinate project activities using management controls to deliver optimal customer value. The project management practices include clear scope definition, schedule/budget tracking, risk/issue resolution and team coordination.

  5. Implementation of Energy Code Controls Requirements in New Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hatten, Mike [Solarc Energy Group, LLC, Seattle, WA (United States); Jones, Dennis [Group 14 Engineering, Inc., Denver, CO (United States); Cooper, Matthew [Group 14 Engineering, Inc., Denver, CO (United States)

    2017-03-24

    Most state energy codes in the United States are based on one of two national model codes; ANSI/ASHRAE/IES 90.1 (Standard 90.1) or the International Code Council (ICC) International Energy Conservation Code (IECC). Since 2004, covering the last four cycles of Standard 90.1 updates, about 30% of all new requirements have been related to building controls. These requirements can be difficult to implement and verification is beyond the expertise of most building code officials, yet the assumption in studies that measure the savings from energy codes is that they are implemented and working correctly. The objective of the current research is to evaluate the degree to which high impact controls requirements included in commercial energy codes are properly designed, commissioned and implemented in new buildings. This study also evaluates the degree to which these control requirements are realizing their savings potential. This was done using a three-step process. The first step involved interviewing commissioning agents to get a better understanding of their activities as they relate to energy code required controls measures. The second involved field audits of a sample of commercial buildings to determine whether the code required control measures are being designed, commissioned and correctly implemented and functioning in new buildings. The third step includes compilation and analysis of the information gather during the first two steps. Information gathered during these activities could be valuable to code developers, energy planners, designers, building owners, and building officials.

  6. Accuracy of CO2 sensors in commercial buildings: a pilotstudy

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

    2006-10-01

    Carbon dioxide (CO{sub 2}) sensors are often deployed in commercial buildings to obtain CO{sub 2} data that are used to automatically modulate rates of outdoor air supply. The goal is to keep ventilation rates at or above code requirements, but to also to save energy by avoiding over ventilation relative to code requirements. However, there have been many anecdotal reports of poor CO{sub 2} sensor performance in actual commercial building applications. This study evaluated the accuracy of 44 CO{sub 2} sensors located in nine commercial buildings to determine if CO{sub 2} sensor performance, in practice, is generally acceptable or problematic. CO{sub 2} measurement errors varied widely and were sometimes hundreds of parts per million. Despite its small size, this study provides a strong indication that the accuracy of CO{sub 2} sensors used in commercial buildings is frequently less than is needed to measure peak indoor-outdoor CO{sub 2} concentration differences with less than a 20% error. Thus, we conclude that there is a need for more accurate CO{sub 2} sensors and/or better sensor maintenance or calibration procedures.

  7. Indoor air quality measurements in 38 Pacific Northwest commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Turk, B.H.; Brown, J.T.; Geisling-Sobotka, K.; Froehlich, D.A.; Grimsrud, D.T.; Harrison, J.; Revzan, K.L.

    1986-06-01

    A Bonneville Power Administration-funded study monitored ventilation rates and a variety of indoor air pollutants in 38 Pacific Northwest commercial buildings. The buildings ranged in age from 6 months to 90 years, in size from 864 to 34,280 m/sup 2/, and occupancy from 25 to 2500 people. Building average formaldehyde (HCHO) concentrations were below the 20 ppB detection limit in 48% of the buildings. Nitrogen dioxide (NO/sub 2/) concentration averages ranged from 5 ppB to 43 ppB and were lower than outdoor concentrations in 8 of 13 buildings. At only one site, an elementary school classroom, did carbon dioxide (CO/sub 2/) exceed 1000 ppM. Radon (Rn) levels were elevated in one building with an average concentration of 7.4 pCiL/sup -1/. Respirable particles (RSP) concentrations in smoking areas in 32 buildings had a geometric mean of 44 ..mu..g m/sup -3/ and ranged up to 308 ..mu..g m/sup -3/ at one site. In non-smoking areas the geometric mean RSP was 15 ..mu..g m/sup -3/. Outside air ventilation rates did not appear to be the single dominant parameter in determining indoor pollutant concentrations. Measured pollutant concentrations in 2 ''complaint'' buildings were below accepted guidelines. The cause of the complaints was not identified.

  8. BEPS redesign of 168 commercial buildings: summary report

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J.L.; Deringer, J.J.; Moreno, S.; Misuriello, H.P.

    1984-05-01

    The objective of this report is to present, in usable form, summary data from the Building Energy Performance Standards (BEPS) Phase II commercial buildings energy research conducted in 1978-1979. Summary data presented were obtained from two major research efforts: the BEPS Phase II Redesign experiment; and the related research on ASHRAE Standard 90-75R. The bulk of this report consists of data tabulations of key energy parameters for the 168 sample buildings, which were tabulated from computer-stored files of the 1978-1979 data. Two kinds of tabulations are included: numerical tabulations that extracted information from the computer-stored data base for the 168 sample buildings; and graphic presentations of the computer-generated data, plus data extracted from other sources. The intent is to provide a single data compendium of key energy-related factors from the 1978 redesign experiment and the associated 1978-1979 ASHRAE Standard 90-75R research. This report also supplements the information for which there was not space in the magazine articles. Thus, for some building types, additional analysis, comments, and data tabulations are included that could not be included in the articles because space was limited. These additional analysis items are not consistent across building types because both the energy conservation opportunities and the design strategies applied by the building designers varied considerably by building type. The chapters have been entered individually into EDB and ERA.

  9. Energy consumption quota management of Wanda commercial buildings in China

    Science.gov (United States)

    Sun, D. B.; Xiao, H.; Wang, X.; Liu, J. J.; Wang, X.; Jin, X. Q.; Wang, J.; Xie, X. K.

    2016-08-01

    There is limited research of commercial buildings’ energy use data conducted based on practical analysis in China nowadays. Some energy consumption quota tools like Energy Star in U.S or VDI 3807 in Germany have limitation in China's building sector. This study introduces an innovative methodology of applying energy use quota model and empirical management to commercial buildings, which was in accordance of more than one hundred opened shopping centers of a real estate group in China. On the basis of statistical benchmarking, a new concept of “Modified coefficient”, which considers weather, occupancy, business layout, operation schedule and HVAC efficiency, is originally introduced in this paper. Our study shows that the average energy use quota increases from north to south. The average energy use quota of sample buildings is 159 kWh/(m2.a) of severe cold climate zone, 179 kWh/(m2.a) of cold zone, 188 kWh/(m2.a) of hot summer and cold winter zone, and 200 kWh/(m2.a) of hot summer and warm winter zone. The energy use quota model has been validated in the property management for year 2016, providing a new method of commercial building energy management to the industry. As a key result, there is 180 million energy saving potential based on energy quota management in 2016, equals to 6.2% saving rate of actual energy use in 2015.

  10. Commercial building design and energy conservation: a preliminary assessment

    Energy Technology Data Exchange (ETDEWEB)

    Nieves, A.; Rosoff, D.

    1982-02-01

    The purpose of the research was to determine the degree of change in commercial building design practice relating to energy conservation since the enactment of the Energy Conservation Standard for New Buildings Act of 1976. Data on current design practices consisted of information from 400 buildings advertised for bids or under construction in 1979 to 1980 on glass in windows and doors, exterior wall systems, roof system, heating plants, and lighting systems. In addition to these building design components, energy conservation measures used included: natural lighting; deadband thermostat; greenhouse-effect atrium collector, heat recovery from the top of the atrium, greenhouse passive heating panels; natural ventilation; insulating shutters, closable skylights, thermal shutters, Trombe wall, corridor trombe; attic ventilation; wind shielding, concrete wall; titlted windows; night flushing cycle; and cooling coils using cooling tower water. A brief explanation of these measures is given. (MCW)

  11. Commercial Buildings Partnerships - Overview of Higher education projects

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, Kristen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Robinson, Alastair [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Regnier, Cindy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-02-01

    The Commercial Building Partnership (CBP), a public/private, cost-shared program sponsored by the U.S. Department of Energy (DOE), paired selected commercial building owners and operators with representatives of DOE, its national laboratories, and private-sector technical experts. These teams explored energy-saving measures across building systems – including some considered too costly or technologically challenging – and used advanced energy modeling to achieve peak whole-building performance. Modeling results were then included in new construction or retrofit designs to achieve significant energy reductions. CBP design goals aimed to achieve 50 percent energy savings compared to ANSI/ASHRAE/IES Standard 90.1-2004 for new construction, while retrofits are designed to consume at least 30 percent less energy than either Standard 90.1-2004 or current consumption. After construction and commissioning of the project, laboratory staff continued to work with partners to collect and analyze data for verification of the actual energy reduction. CBP projects represent diverse building types in commercial real estate, including lodging, grocery, retail, higher education, office, and warehouse/storage facilities. Partners also commit to replicating low-energy technologies and strategies from their CBP projects throughout their building portfolios. As a result of CBP projects, five sector overviews (Lodging, Food Sales, General Merchandise, Higher Education, Offices) were created to capture successful strategies and recommended energy efficiency measures that could broadly be applied across these sectors. These overviews are supplemented with individual case studies providing specific details on the decision criteria, modeling results, and lessons learned on specific projects. Sector overviews and CBP case studies will also be updated to reflect verified data and replication strategies as they become available.

  12. Commercial Buildings Partnerships - Overview of Higher Education Projects

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, Kristen; Robinson, Alastair; Regnier, Cindy

    2013-02-01

    The Commercial Building Partnership (CBP), a public/private, cost-shared program sponsored by the U.S. Department of Energy (DOE), paired selected commercial building owners and operators with representatives of DOE, its national laboratories, and private-sector technical experts. These teams explored energy-saving measures across building systems – including some considered too costly or technologically challenging – and used advanced energy modeling to achieve peak whole-building performance. Modeling results were then included in new construction or retrofit designs to achieve significant energy reductions. CBP design goals aimed to achieve 50 percent energy savings compared to ANSI/ASHRAE/IES Standard 90.1-2004 for new construction, while retrofits are designed to consume at least 30 percent less energy than either Standard 90.1-2004 or current consumption. After construction and commissioning of the project, laboratory staff continued to work with partners to collect and analyze data for verification of the actual energy reduction. CBP projects represent diverse building types in commercial real estate, including lodging, grocery, retail, higher education, office, and warehouse/storage facilities. Partners also commit to replicating low-energy technologies and strategies from their CBP projects throughout their building portfolios. As a result of CBP projects, five sector overviews (Lodging, Food Sales, General Merchandise, Higher Education, Offices) were created to capture successful strategies and recommended energy efficiency measures that could broadly be applied across these sectors. These overviews are supplemented with individual case studies providing specific details on the decision criteria, modeling results, and lessons learned on specific projects. Sector overviews and CBP case studies will also be updated to reflect verified data and replication strategies as they become available.

  13. Commercial Building Design Pathways Using Optimization Analysis: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Long, N.; Hirsch, A.; Lobato, C.; Macumber, D.

    2010-08-01

    Whole-building simulation and analysis has demonstrated a significant energy savings potential in a wide variety of design projects. Commercial building design, however, traditionally integrates simulation and modeling analyses too late in the design process to make a substantial impact on energy use. The National Renewable Energy Laboratory (NREL) commercial building group created an optimization platform called Opt-E-Plus that uses multivariate and multi-objective optimization theory to navigate a large parameter space and find economically valid, energy-saving solutions. The analysis results provide designers and engineers valuable information that influences the design. The pathways are not full 'construction ready' design alternatives; rather, they offer guidance about performance and cost criteria to reach a range of energy and economic goals. Having this knowledge early in the design phase helps designers establish project goals and direct the design pathway before they make important decisions. Opt-E-Plus has been deployed on several projects, including a retrofit mixed-use building, a new NREL office building, and several nationwide design guides. Each of these projects had different design criteria, goals, and audiences. In each case the analysis results provided pathways that helped inform the design process.

  14. Using DOE Commercial Reference Buildings for Simulation Studies: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Field, K.; Deru, M.; Studer, D.

    2010-08-01

    The U.S. Department of Energy developed 256 EnergyPlus models for use in studies that aim to characterize about 70% of the U.S. commercial building stock. Sixteen building types - including restaurants, health care, schools, offices, supermarkets, retail, lodging, and warehouses - are modeled across 16 cities to represent the diversity of U.S. climate zones. Weighting factors have been developed to combine the models in proportions similar to those of the McGraw-Hill Construction Projects Starts Database for 2003-2007. This paper reviews the development and contents of these models and their applications in simulation studies.

  15. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

    2010-10-27

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

  16. Commercializing Government-sponsored Innovations: Twelve Successful Buildings Case Studies

    Science.gov (United States)

    Brown, M. A.; Berry, L. G.; Goel, R. K.

    1989-01-01

    This report examines the commercialization and use of R and D results funded by DOE's Office of Buildings and Community Systems (OBCS), an office that is dedicated to improving the energy efficiency of the nation's buildings. Three goals guided the research described in this report: to improve understanding of the factors that hinder or facilitate the transfer of OBCS R and D results, to determine which technology transfer strategies are most effective and under what circumstances each is appropriate, and to document the market penetration and energy savings achieved by successfully-commercialized innovations that have received OBCS support. Twelve successfully-commercialized innovations are discussed here. The methodology employed involved a review of the literature, interviews with innovation program managers and industry personnel, and data collection from secondary sources. Six generic technology transfer strategies are also described. Of these, contracting R and D to industrial partners is found to be the most commonly used strategy in our case studies. The market penetration achieved to date by the innovations studied ranges from less than 1% to 100%. For the three innovations with the highest predicted levels of energy savings (i.e., the flame retention head oil burner, low-E windows, and solid-state ballasts), combined cumulative savings by the year 2000 are likely to approach 2 quads. To date the energy savings for these three innovations have been about 0.2 quads. Our case studies illustrate the important role federal agencies can play in commercializing new technologies.

  17. Guidelines for Energy Simulation of Commercial Buildings: Final.

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, Michael; Caner, Phoebe

    1992-03-01

    This report distills the experience gained from intensive computer building simulation work for the Energy Edge project. The purpose of this report is twofold: to use that experience to guide conservation program managers in their use of modeling, and to improve the accuracy of design-phase computer models. Though the main emphasis of the report is on new commercial construction, it also addresses modeling as it pertains to retrofit construction. To achieve these purposes, this report will: (1) discuss the value of modeling for energy conservation programs; (2) discuss strengths and weaknesses of computer models; (3) provide specific guidelines for model input; (4) discuss input topics that are unusually large drivers of energy use and model inaccuracy; (5) provide guidelines for developing baseline models; (6) discuss types of energy conservation measures (ECMs) and building operation that are not suitable to modeling and present possible alternatives to modeling for analysis; and (7) provide basic requirements for model documentation. This project was initiated to determine whether commercial buildings can be designed and constructed to use at least 30% less energy than if they were designed and built to meet the current regional model energy code, the Model Conservation Standards (MCS) developed by the Pacific Northwest Electric Power and Conservation Planning Council. Secondary objectives of the project are to determine the incremental energy savings of a wide variety of ECMs and to compare the predictive accuracy of design-phase models with models that are carefully tuned to monitored building data.

  18. 2020 Leadership Agenda for Existing Commercial and Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Burr, Andrew [Dept. of Energy (DOE), Washington DC (United States). Office of Energy Efficiency and Renewable Energy; Goldthwaite, Carolyn Sarno [Northeast Energy Efficiency Partnerships (NEEP), Boston, MA (United States). High Performance Buildings; Coffman, Eric [Montgomery County Dept. of General Services, Rockville, MD (United States). Office of Energy and Sustainability

    2016-01-21

    Leadership by state and local governments is critical to unlock national energy efficiency opportunities and deliver the benefits of efficiency to all Americans. But related to building energy efficiency, what will it mean to be a public sector leader over the next several years? What are the energy efficiency solutions that cities, counties, and states are implementing today that will make their communities more affordable, livable, healthy, and economically competitive? The SEE Action Network 2020 Leadership Agenda for Existing Commercial and Multifamily Buildings establishes a benchmark for state and local government leadership on improving the energy efficiency of buildings and seeks two-way collaboration among state, local, and federal officials. It defines a suite of innovative, yet practical policies and programs for policymakers to consider implementing by 2020, focusing on six important areas.

  19. Building-to-Grid Integration through Commercial Building Portfolios Participating in Energy and Frequency Regulation Markets

    Science.gov (United States)

    Pavlak, Gregory S.

    Building energy use is a significant contributing factor to growing worldwide energy demands. In pursuit of a sustainable energy future, commercial building operations must be intelligently integrated with the electric system to increase efficiency and enable renewable generation. Toward this end, a model-based methodology was developed to estimate the capability of commercial buildings to participate in frequency regulation ancillary service markets. This methodology was integrated into a supervisory model predictive controller to optimize building operation in consideration of energy prices, demand charges, and ancillary service revenue. The supervisory control problem was extended to building portfolios to evaluate opportunities for synergistic effect among multiple, centrally-optimized buildings. Simulation studies performed showed that the multi-market optimization was able to determine appropriate opportunities for buildings to provide frequency regulation. Total savings were increased by up to thirteen percentage points, depending on the simulation case. Furthermore, optimizing buildings as a portfolio achieved up to seven additional percentage points of savings, depending on the case. Enhanced energy and cost savings opportunities were observed by taking the novel perspective of optimizing building portfolios in multiple grid markets, motivating future pursuits of advanced control paradigms that enable a more intelligent electric grid.

  20. Commercial Building Energy Asset Rating Program -- Market Research

    Energy Technology Data Exchange (ETDEWEB)

    McCabe, Molly J.; Wang, Na

    2012-04-19

    Under contract to Pacific Northwest National Laboratory, HaydenTanner, LLC conducted an in-depth analysis of the potential market value of a commercial building energy asset rating program for the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy. The market research objectives were to: (1) Evaluate market interest and need for a program and tool to offer asset rating and rapidly identify potential energy efficiency measures for the commercial building sector. (2) Identify key input variables and asset rating outputs that would facilitate increased investment in energy efficiency. (3) Assess best practices and lessons learned from existing national and international energy rating programs. (4) Identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to adopt a voluntary asset rating program and, as a consequence, deploy high-performance strategies and technologies across new and existing buildings. (5) Identify leverage factors and incentives that facilitate increased investment in these buildings. To meet these objectives, work consisted of a review of the relevant literature, examination of existing and emergent asset and operational rating systems, interviews with industry stakeholders, and an evaluation of the value implication of an asset label on asset valuation. This report documents the analysis methodology and findings, conclusion, and recommendations. Its intent is to support and inform the DOE Office of Energy Efficiency and Renewable Energy on the market need and potential value impacts of an asset labeling and diagnostic tool to encourage high-performance new buildings and building efficiency retrofit projects.

  1. Performance of thermal distribution systems in large commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Tengfang [Lawrence Berkeley National Lab. (LBNL), Univ. of California, Berkeley, CA (United States); Carrie, Remi F. [Lawrence Berkeley National Lab. (LBNL), Univ. of California, Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Univ. of California, Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Univ. of California, Berkeley, CA (United States); McWilliams, Jennifer [Lawrence Berkeley National Lab. (LBNL), Univ. of California, Berkeley, CA (United States); Wang, Duo [Lawrence Berkeley National Lab. (LBNL), Univ. of California, Berkeley, CA (United States); Modera, Mark P. [Lawrence Berkeley National Lab. (LBNL), Univ. of California, Berkeley, CA (United States)

    2001-12-08

    This paper presents major findings of a field study on the performance of five thermal distribution systems in four large commercial buildings. The five systems studied are typical single-duct or dual-duct constant air volume (CAV) systems and variable air volume (VAV) systems, each of which serves an office building or a retail building with floor area over 2000 m2. The air leakage from ducts is reported in terms of effective leakage area (ELA) at 25 Pa reference pressure, the ASHRAE-defined duct leakage class CL, and air leakage ratios. The specific ELAs ranged from 0.7 to 12.9 cm2/m2 of duct surface area, and from 0.1 to 7.7 cm2/m2 of floor area served. The ASHRAE-defined duct leakage classes ranged from 34 to 606 for the five systems and systems sections tested. The air leakage ratios were estimated to be up to approximately one-third of the fan-supplied airflow in the constant air volume systems. The specific ELAs and leakage classes indicated that air leakage in large commercial duct systems varied significantly from system to system, and from system section to system section even within the same thermal distribution system. Overall, the duct systems measured were much leakier than the ductwork specified as “unsealed ducts” by ASHRAE. On the other hand, thermal losses from supply ducts induced by conduction (including convection and radiation) were significant, on the scale that was comparable to the losses induced by air leakage in the duct systems. Furthermore, the energy losses induced by leakage and conduction suggested that there exist significant energy savings potentials from duct sealing and duct insulation practice in large commercial buildings.

  2. Potential for energy technologies in residential and commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Glesk, M.M.

    1979-11-01

    The residential-commercial energy technology model was developed as a planning tool for policy analysis in the residential and commercial building sectors. The model and its procedures represent a detailed approach to estimating the future acceptance of energy-using technologies both in new construction and for retrofit into existing buildings. The model organizes into an analytical framework all relevant information and data on building energy technology, building markets, and government policy, and it allows for easy identification of the relative importance of key assumptions. The outputs include estimates of the degree of penetration of the various building energy technologies, the levels of energy use savings associated with them, and their costs - both private and government. The model was designed to estimate the annual energy savings associated with new technologies compared with continued use of conventional technology at 1975 levels. The amount of energy used under 1975 technology conditions is referred to as the reference case energy use. For analytical purposes the technologies were consolidated into ten groupings: electric and gas heat pumps; conservation categories I, II, and III; solar thermal (hot water, heating, and cooling); photovoltaics, and wind systems. These groupings clearly do not allow an assessment of the potential for individual technologies, but they do allow a reasonable comparison of their roles in the R/C sector. Assumptions were made regarding the technical and economic performances of the technologies over the period of the analysis. In addition, the study assessed the non-financial characteristics of the technologies - aesthetics, maintenance complexity, reliability, etc. - that will also influence their market acceptability.

  3. Commercializing government-sponsored innovations: Twelve successful buildings case studies

    Energy Technology Data Exchange (ETDEWEB)

    Brown, M.A.; Berry, L.G.; Goel, R.K.

    1989-01-01

    This report examines the commercialization and use of R and D results funded by DOE's Office of Buildings and Community Systems (OBCS), an office that is dedicated to improving the energy efficiency of the nation's buildings. Three goals guided the research described in this report: to improve understanding of the factors that hinder or facilitate the transfer of OBCS R and D results, to determine which technology transfer strategies are most effective and under what circumstances each is appropriate, and to document the market penetration and energy savings achieved by successfully-commercialized innovations that have received OBCS support. Twelve successfully-commercialized innovations are discussed here. The methodology employed involved a review of the literature, interviews with innovation program managers and industry personnel, and data collection from secondary sources. Six generic technology transfer strategies are also described. Of these, contracting R and D to industrial partners is found to be the most commonly used strategy in our case studies. The market penetration achieved to date by the innovations studied ranges from less than 1% to 100%. For the three innovations with the highest predicted levels of energy savings (i.e., the flame retention head oil burner, low-E windows, and solid-state ballasts), combined cumulative savings by the year 2000 are likely to approach 2 quads. To date the energy savings for these three innovations have been about 0.2 quads. Our case studies illustrate the important role federal agencies can play in commercializing new technologies. 27 refs., 21 figs., 4 tabs.

  4. Integrated envelope and lighting systems for commercial buildings: a retrospective

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor S.; Selkowitz, Stephen E.

    1998-06-01

    Daylighting systems in use world-wide rarely capture the energy-savings predicted by simulation tools and that we believe are achievable in real buildings. One of the primary reasons for this is that window and lighting systems are not designed and operated as an integrated system. Our efforts over the last five years have been targeted toward (1) development and testing of new prototype systems that involve a higher degree of systems integration than has been typical in the past, and (2) addressing current design and technological barriers that are often missed with component-oriented research. We summarize the results from this body of cross-disciplinary research and discuss its effects on the existing and future practice of daylighting in commercial buildings.

  5. Commercial Buildings Partnership Projects - Metered Data Format and Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas

    2010-11-16

    A number of the Commercial Building Partnership Projects (CBPs) will require metering, monitoring, data analysis and verification of savings after the retrofits are complete. Although monitoring and verification (M&V) agents are free to use any metering and monitoring devices that they chose, the data they collect should be reported to Pacific Northwest National Laboratory (PNNL) in a standard format. PNNL will store the data collected in its CBP database for further use by PNNL and U.S. Department of Energy. This document describes the data storage process and the deliver format of the data from the M&V agents.

  6. Building energy, building leadership : recommendations for the adoption, development, and implementation of a commercial building energy code in Manitoba

    Energy Technology Data Exchange (ETDEWEB)

    Akerstream, T. [Manitoba Hydro, Winnipeg, MB (Canada); Allard, K. [City of Thompson, Thompson, MB (Canada); Anderson, N.; Beacham, D. [Manitoba Office of the Fire Commissioner, Winnipeg, MB (Canada); Andrich, R. [The Forks North Portage Partnership, MB (Canada); Auger, A. [Natural Resources Canada, Ottawa, ON (Canada). Office of Energy Efficiency; Downs, R.G. [Shindico Realty Inc., Winnipeg, MB (Canada); Eastwood, R. [Number Ten Architectural Group, Winnipeg, MB (Canada); Hewitt, C. [SMS Engineering Ltd., Winnipeg, MB (Canada); Joshi, D. [City of Winnipeg, Winnipeg, MB (Canada); Klassen, K. [Manitoba Dept. of Energy Science and Technology, Winnipeg, MB (Canada); Phillips, B. [Unies Ltd., Winnipeg, MB (Canada); Wiebe, R. [Ben Wiebe Construction Ltd., Winnipeg, MB (Canada); Woelk, D. [Bockstael Construction Ltd., Winnipeg, MB (Canada); Ziemski, S. [CREIT Management LLP, Winnipeg, MB (Canada)

    2006-09-15

    This report presented a strategy and a set of recommendations for the adoption, development and implementation of an energy code for new commercial construction in Manitoba. The report was compiled by an advisory committee comprised of industry representatives and government agency representatives. Recommendations were divided into 4 categories: (1) advisory committee recommendations; (2) code adoption recommendations; (3) code development recommendations; and (4) code implementation recommendations. It was suggested that Manitoba should adopt an amended version of the Model National Energy Code for Buildings (1997) as a regulation under the Buildings and Mobile Homes Act. Participation in a national initiative to update the Model National Energy Code for Buildings was also advised. It was suggested that the energy code should be considered as the first step in a longer-term process towards a sustainable commercial building code. However, the code should be adopted within the context of a complete market transformation approach. Other recommendations included: the establishment of a multi-stakeholder energy code task group; the provision of information and technical resources to help build industry capacity; the establishment of a process for energy code compliance; and an ongoing review of the energy code to assess impacts and progress. Supplemental recommendations for future discussion included the need for integrated design by building design teams in Manitoba; the development of a program to provide technical assistance to building design teams; and collaboration between post-secondary institutions to develop and deliver courses on integrated building design to students and professionals. 17 refs.

  7. Thermal energy storage for cooling of commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, H. (Lawrence Berkeley Lab., CA (USA)); Mertol, A. (Science Applications International Corp., Los Altos, CA (USA))

    1988-07-01

    The storage of coolness'' has been in use in limited applications for more than a half century. Recently, because of high electricity costs during utilities' peak power periods, thermal storage for cooling has become a prime target for load management strategies. Systems with cool storage shift all or part of the electricity requirement from peak to off-peak hours to take advantage of reduced demand charges and/or off-peak rates. Thermal storage technology applies equally to industrial, commercial, and residential sectors. In the industrial sector, because of the lack of economic incentives and the custom design required for each application, the penetration of this technology has been limited to a few industries. The penetration rate in the residential sector has been also very limited due to the absence of economic incentives, sizing problems, and the lack of compact packaged systems. To date, the most promising applications of these systems, therefore, appear to be for commercial cooling. In this report, the current and potential use of thermal energy storage systems for cooling commercial buildings is investigated. In addition, a general overview of the technology is presented and the applicability and cost-effectiveness of this technology for developed and developing countries are discussed. 28 refs., 12 figs., 1 tab.

  8. Using EMIS to Identify Top Opportunities for Commercial Building Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Guanjing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singla, Rupam [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Granderson, Jessica [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-04-11

    Energy Management and Information Systems (EMIS) comprise a broad family of tools and services to manage commercial building energy use. These technologies offer a mix of capabilities to store, display, and analyze energy use and system data, and in some cases, provide control. EMIS technologies enable 10–20 percent site energy savings in best practice implementations. Energy Information System (EIS) and Fault Detection and Diagnosis (FDD) systems are two key technologies in the EMIS family. Energy Information Systems are broadly defined as the web-based software, data acquisition hardware, and communication systems used to analyze and display building energy performance. At a minimum, an EIS provides daily, hourly or sub-hourly interval meter data at the whole-building level, with graphical and analytical capability. Fault Detection and Diagnosis systems automatically identify heating, ventilation, and air-conditioning (HVAC) system or equipment-level performances issues, and in some cases are able to isolate the root causes of the problem. They use computer algorithms to continuously analyze system-level operational data to detect faults and diagnose their causes. Many FDD tools integrate the trend log data from a Building Automation System (BAS) but otherwise are stand-alone software packages; other types of FDD tools are implemented as “on-board” equipment-embedded diagnostics. (This document focuses on the former.) Analysis approaches adopted in FDD technologies span a variety of techniques from rule-based methods to process history-based approaches. FDD tools automate investigations that can be conducted via manual data inspection by someone with expert knowledge, thereby expanding accessibility and breath of analysis opportunity, and also reducing complexity.

  9. Functional Testing Protocols for Commercial Building Efficiency Baseline Modeling Software

    Energy Technology Data Exchange (ETDEWEB)

    Jump, David; Price, Phillip N.; Granderson, Jessica; Sohn, Michael

    2013-09-06

    This document describes procedures for testing and validating proprietary baseline energy modeling software accuracy in predicting energy use over the period of interest, such as a month or a year. The procedures are designed according to the methodology used for public domain baselining software in another LBNL report that was (like the present report) prepared for Pacific Gas and Electric Company: ?Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing Protocols? (referred to here as the ?Model Analysis Report?). The test procedure focuses on the quality of the software?s predictions rather than on the specific algorithms used to predict energy use. In this way the software vendor is not required to divulge or share proprietary information about how their software works, while enabling stakeholders to assess its performance.

  10. A look at commercial buildings in 1995: Characteristics, energy consumption, and energy expenditures

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-10-01

    The commercial sector consists of business establishments and other organizations that provide services. The sector includes service businesses, such as retail and wholesale stores, hotels and motels, restaurants, and hospitals, as well as a wide range of facilities that would not be considered commercial in a traditional economic sense, such as public schools, correctional institutions, and religious and fraternal organizations. Nearly all energy use in the commercial sector takes place in, or is associated with, the buildings that house these commercial activities. Analysis of the structures, activities, and equipment associated with different types of buildings is the clearest way to evaluate commercial sector energy use. The Commercial Buildings Energy Consumption Survey (CBECS) is a national-level sample survey of commercial buildings and their energy suppliers conducted quadrennially (previously triennially) by the Energy Information Administration (EIA). The target population for the 1995 CBECS consisted of all commercial buildings in the US with more than 1,000 square feet of floorspace. Decision makers, businesses, and other organizations that are concerned with the use of energy--building owners and managers, regulators, legislative bodies and executive agencies at all levels of government, utilities and other energy suppliers--are confronted with a buildings sector that is complex. Data on major characteristics (e.g., type of building, size, year constructed, location) collected from the buildings, along with the amount and types of energy the buildings consume, help answer fundamental questions about the use of energy in commercial buildings.

  11. Commercial building end-use energy metering inventory

    Energy Technology Data Exchange (ETDEWEB)

    Heidell, J.A.; Mazzucchi, R.P.; Reilly, R.W.

    1985-03-01

    Pacific Northwest Laboratory conducted a comprehensive inventory of end-use metered data. The inventory did not discover many sources of metered end-use data; however, research into existing data bases and extensive discussions with professionals associated with building energy conservation have enabled a clear characterization to be developed of the types of metered data that are required to further energy conservation in commercial buildings. Based on the results of the inventory and this clarification of data requirements, the adequacy of existing data bases has been assessed, and recommendations have been developed for future federal data collection efforts. A summary of sources of existing metered end-use data is provided in Section 2.1 and its adequacy has been summarized. Collection of further end-use metered data is both desirable and valuable for many areas of building energy conservation research. Empirical data are needed to address many issues which to date have been addressed using only simulation techniques. The adequacy of using simulation techniques for various purposes needs to be assessed through comparison with measured data. While these data are expensive to acquire, it is cost-effective to do so in the long run, and the need is not being served by the private market. The preceding conclusion based on results from the inventory of existing data highlights two important facts: First, although the data are widely desired in the private sector, they are not widely available. Second, where suitable data are publicly available and contain the desired supporting information, their collection has generally been funded by government-sponsored research.

  12. Commercial Building Energy Asset Rating Tool User's Guide

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na; Makhmalbaf, Atefe; Matsumoto, Steven W.

    2012-05-01

    The U.S. Department of Energy’s Commercial Building Energy Asset Rating Tool is a web-based system that is designed to allow building owners, managers, and operators to more accurately assess the energy performance of their commercial buildings. This document provide a step-by-step instruction on how to use the tool.

  13. Software augmented buildings: Exploiting existing infrastructure to improve energy efficiency and comfort in commercial buildings

    Science.gov (United States)

    Balaji, Bharathan

    Commercial buildings consume 19% of energy in the US as of 2010, and traditionally, their energy use has been optimized through improved equipment efficiency and retrofits. Beyond improved hardware and infrastructure, there exists a tremendous potential in reducing energy use through better monitoring and operation. We present several applications that we developed and deployed to support our thesis that building energy use can be reduced through sensing, monitoring and optimization software that modulates use of building subsystems including HVAC. We focus on HVAC systems as these constitute 48-55% of building energy use. Specifically, in case of sensing, we describe an energy apportionment system that enables us to estimate real-time zonal HVAC power consumption by analyzing existing sensor information. With this energy breakdown, we can measure effectiveness of optimization solutions and identify inefficiencies. Central to energy efficiency improvement is determination of human occupancy in buildings. But this information is often unavailable or expensive to obtain using wide scale sensor deployment. We present our system that infers room level occupancy inexpensively by leveraging existing WiFi infrastructure. Occupancy information can be used not only to directly control HVAC but also to infer state of the building for predictive control. Building energy use is strongly influenced by human behaviors, and timely feedback mechanisms can encourage energy saving behavior. Occupants interact with HVAC using thermostats which has shown to be inadequate for thermal comfort. Building managers are responsible for incorporating energy efficiency measures, but our interviews reveal that they struggle to maintain efficiency due to lack of analytical tools and contextual information. We present our software services that provide energy feedback to occupants and building managers, improves comfort with personalized control and identifies energy wasting faults. For wide

  14. Energy Savings Modeling of Standard Commercial Building Re-tuning Measures: Large Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas; Katipamula, Srinivas; Wang, Weimin; Huang, Yunzhi; Liu, Guopeng

    2012-06-01

    Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS's capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This report investigates the energy savings potential of several common HVAC system retuning measures on a typical large office building prototype model, using the Department of Energy's building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated - each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All of these measures and combinations were simulated in 16 cities representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy

  15. Both Sides of the Interface: Building an Education Interface for a Digital Video Archive with an Interprofessional Group

    Science.gov (United States)

    Thompson, Ella Belzberg

    2014-01-01

    In 1999, it was necessary to build an interface for the Shoah Foundation's Visual History Archive (the world's largest digital video archive at the time) that constituted over 120,000 hours of video of over 52,000 video testimonies of Holocaust survivors, rescuers and witnesses. In order to build this educational research interface, an…

  16. An Examination of the Performance Based Building Code on the Design of a Commercial Building

    Directory of Open Access Journals (Sweden)

    John Greenwood

    2012-11-01

    Full Text Available The Building Code of Australia (BCA is the principal code under which building approvals in Australia are assessed. The BCA adopted performance-based solutions for building approvals in 1996. Performance-based codes are based upon a set of explicit objectives, stated in terms of a hierarchy of requirements beginning with key general objectives. With this in mind, the research presented in this paper aims to analyse the impact of the introduction of the performance-based code within Western Australia to gauge the effect and usefulness of alternative design solutions in commercial construction using a case study project. The research revealed that there are several advantages to the use of alternative designs and that all parties, in general, are in favour of the performance-based building code of Australia. It is suggested that change in the assessment process to streamline the alternative design path is needed for the greater use of the performance-based alternative. With appropriate quality control measures, minor variations to the deemed-to-satisfy provisions could easily be managed by the current and future building surveying profession.

  17. Exploring the Client–AEC Interface in Building Lifecycle Integration

    Directory of Open Access Journals (Sweden)

    John M. Kamara

    2013-07-01

    Full Text Available The creation and management of buildings over their lifecycle involves the cooperation of many organizations, which broadly fall into a client domain and AEC (architecture, engineering, construction domain. While this mix of expertise is essential, the ineffective management of the boundaries between these organizations can undermine building lifecycle performance. This paper explores client–AEC interactions at the project development and handover stages, with a view to discovering insights into client–AEC interface management for effective building lifecycle integration (BLI. The concept of boundary objects provided the theoretical framework to discuss findings from two case studies on the project development phase of a private finance initiative project, and the asset development process in a repeat client organization. The findings suggest that there are different emphases in boundary crossing activities at different stages, with boundary roles that relate to decision-making and authority to commit resources being more relevant at the project development stage, whereas the need to explain meanings appear to be more relevant at the handover stage. AEC professionals in client organizations play a crucial role in bridging knowledge boundaries about buildings, but this professional/functional strand to BLI needs to be effectively managed alongside the organizational boundaries, since the authority to resource BLI efforts resides within organizations.

  18. Commercial building systems analysis. Final report, January 1988-July 1989

    Energy Technology Data Exchange (ETDEWEB)

    Glazer, J.; Henninger, R.H.

    1991-07-01

    The report describes the methodology used for conducting an economic analysis of Gas Heat Pumps (GHP's) and competing space conditioning equipment in the light commercial range. The economic analysis began by obtaining equipment installed costs and determining the yearly energy usage for each type of space conditioning equipment applied to a small office building and quick service restaurant in 17 cities. The installed costs of competing technologies were obtained via a survey in various cities throughout the United States. The yearly energy costs for this equipment and GHP's were calculated by using the DOE-2.1C Hourly Energy Analysis Computer Program. The DOE-2 program was modified specifically to simulate the complexity of gas heat pumps by incorporating special FORTRAN algorithms. Performance curves were developed and included in the GHP computer model based on empirical data. An economic analysis was conducted comparing GHP's and competing equipment using both payback and net present value methods which included an examination of the effect of the change in future utility costs. The results of the analysis are not included in the report because they are based on proprietary performance information.

  19. Demand Responsive and Energy Efficient Control Technologies andStrategies in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Kiliccote, Sila

    2006-09-01

    Commercial buildings account for a large portion of summer peak electric demand. Research results show that there is significant potential to reduce peak demand in commercial buildings through advanced control technologies and strategies. However, a better understanding of commercial buildings contribution to peak demand and the use of energy management and control systems is required to develop this demand response resource to its full potential. The main objectives of the study were: (1) To evaluate the size of contributions of peak demand commercial buildings in the U.S.; (2) To understand how commercial building control systems support energy efficiency and DR; and (3) To disseminate the results to the building owners, facility managers and building controls industry. In order to estimate the commercial buildings contribution to peak demand, two sources of data are used: (1) Commercial Building Energy Consumption Survey (CBECS) and (2) National Energy Modeling System (NEMS). These two sources indicate that commercial buildings noncoincidental peak demand is about 330GW. The project then focused on technologies and strategies that deliver energy efficiency and also target 5-10% of this peak. Based on a building operations perspective, a demand-side management framework with three main features: (1) daily energy efficiency, (2) daily peak load management and (3) dynamic, event-driven DR are outlined. A general description of DR, its benefits, and nationwide DR potential in commercial buildings are presented. Case studies involving these technologies and strategies are described. The findings of this project are shared with building owners, building controls industry, researchers and government entities through a webcast and their input is requested. Their input is presented in the appendix section of this report.

  20. CO2 MONITORING FOR DEMAND CONTROLLED VENTILATION IN COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Sullivan, Douglas P.; Faulkner, David; Eliseeva, Ekaterina

    2010-03-17

    Carbon dioxide (CO{sub 2}) sensors are often deployed in commercial buildings to obtain CO{sub 2} data that are used, in a process called demand-controlled ventilation, to automatically modulate rates of outdoor air ventilation. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. Demand controlled ventilation is most often used in spaces with highly variable and sometime dense occupancy. Reasonably accurate CO{sub 2} measurements are needed for successful demand controlled ventilation; however, prior research has suggested substantial measurement errors. Accordingly, this study evaluated: (a) the accuracy of 208 CO{sub 2} single-location sensors located in 34 commercial buildings, (b) the accuracy of four multi-location CO{sub 2} measurement systems that utilize tubing, valves, and pumps to measure at multiple locations with single CO{sub 2} sensors, and (c) the spatial variability of CO{sub 2} concentrations within meeting rooms. The field studies of the accuracy of single-location CO{sub 2} sensors included multi-concentration calibration checks of 90 sensors in which sensor accuracy was checked at multiple CO{sub 2} concentrations using primary standard calibration gases. From these evaluations, average errors were small, -26 ppm and -9 ppm at 760 and 1010 ppm, respectively; however, the averages of the absolute values of error were 118 ppm (16%) and 138 ppm (14%), at concentrations of 760 and 1010 ppm, respectively. The calibration data are generally well fit by a straight line as indicated by high values of R{sup 2}. The Title 24 standard specifies that sensor error must be certified as no greater than 75 ppm for a period of five years after sensor installation. At 1010 ppm, 40% of sensors had errors greater than {+-}75 ppm and 31% of sensors has errors greater than {+-}100 ppm. At 760 ppm, 47% of sensors had errors greater than {+-}75 ppm and 37% of

  1. Small Commercial Building Re-tuning: A Primer

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Hostick, Donna J.; Underhill, Ronald M.; Fernandez, Nicholas; Katipamula, Srinivas

    2013-09-30

    To help building owners and managers address issues related to energy-efficient operation of small buildings, DOE has developed a Small Building Re-tuning training curriculum. This "primer" provides additional background information to understand some of the concepts presented in the Small Building Re-tuning training. The intent is that those who are less familiar with the buidling energy concepts will review this material before taking the building re-tuning training class.

  2. Ready to Retrofit: The Process of Project Team Selection, Building Benchmarking, and Financing Commercial Building Energy Retrofit Projects

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, Mark D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Parrish, Kristen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mathew, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-01

    This guide presents a process for three key activities for the building owner in preparing to retrofit existing commercial buildings: selecting project teams, benchmarking the existing building, and financing the retrofit work. Although there are other essential steps in the retrofit process, the three activities presented in this guide are the critical elements where the building owner has the greatest influence on the outcome of the project.

  3. 78 FR 9042 - Request for Information (RFI) for Commercial Building Energy Asset Score

    Science.gov (United States)

    2013-02-07

    ... of Energy Efficiency and Renewable Energy Request for Information (RFI) for Commercial Building Energy Asset Score AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy... its effort to achieve a 20 percent improvement in the energy efficiency of commercial buildings...

  4. 40 CFR 745.228 - Accreditation of training programs: public and commercial buildings, bridges and superstructures...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Accreditation of training programs: public and commercial buildings, bridges and superstructures. 745.228 Section 745.228 Protection of... of training programs: public and commercial buildings, bridges and superstructures....

  5. 77 FR 76996 - Lead; Renovation, Repair, and Painting Program for Public and Commercial Buildings; Request for...

    Science.gov (United States)

    2012-12-31

    ..., defined in the rule as a subset of public and commercial buildings in which young children spend a... EPA is interested in. The 2010 ANPRM contains a comprehensive history of this rulemaking and the lead... substances, Public and commercial buildings, Occupational safety and health, Renovations, Repair,...

  6. Commercial Building Tenant Energy Usage Aggregation and Privacy

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, Olga V.; Pulsipher, Trenton C.; Anderson, David M.; Wang, Na

    2014-10-31

    A growing number of building owners are benchmarking their building energy use. This requires the building owner to acquire monthly whole-building energy usage information, which can be challenging for buildings in which individual tenants have their own utility meters and accounts with the utility. Some utilities and utility regulators have turned to aggregation of customer energy use data (CEUD) as a way to give building owners whole-building energy usage data while protecting customer privacy. Meter profile aggregation adds a layer of protection that decreases the risk of revealing CEUD as the number of meters aggregated increases. The report statistically characterizes the similarity between individual energy usage patterns and whole-building totals at various levels of meter aggregation.

  7. Final report on the energy edge impact evaluation of 28 new, low-energy commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Piette, M.A.; Diamond, R.; Nordman, B. [and others

    1994-08-01

    This report presents the findings of the Energy Edge Impact Evaluation. It is the fourth and final report in a series of project impact evaluation reports. Energy Edge is a research-oriented demonstration of energy efficiency in 28 new commercial buildings. Beginning in 1985,the project, sponsored by the Bonneville Power Administration (BPA), was developed to evaluate the potential for electricity conservation in new commercial buildings. By focusing on the construction of new commercial buildings, Energy Edge meets the region`s goal of capturing otherwise lost opportunities to accomplish energy conservation. That is, the best time to add an energy-efficiency measure to a building is during the construction phase.

  8. 29 CFR 779.336 - Sales of building materials for commercial property construction.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Sales of building materials for commercial property... construction, maintenance or repair of commercial property or any other property not excepted in section 3(n... business for the construction, maintenance or repair of commercial property or any other property...

  9. Assessment of the Technical Potential for Achieving Net Zero-Energy Buildings in the Commercial Sector

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.; Long, N.; Torcellini, P.; Judkoff, R.; Crawley, D.; Ryan, J.

    2007-12-01

    This report summarizes the findings from research conducted at NREL to assess the technical potential for zero-energy building technologies and practices to reduce the impact of commercial buildings on the U.S. energy system. Commercial buildings currently account for 18% of annual U.S. energy consumption, and energy use is growing along with overall floor area. Reducing the energy use of this sector will require aggressive research goals and rapid implementation of the research results.

  10. Progress on Enabling an Interactive Conversation Between Commercial Building Occupants and Their Building To Improve Comfort and Energy Efficiency: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Schott, M.; Scheib, J.; Long, N.; Fleming, K.; Benne, K.; Brackney, L.

    2012-06-01

    Many studies have reported energy savings after installing a dashboard, but dashboards provide neither individual feedback to the occupant nor the ability to report individual comfort. The Building Agent (BA) provides an interface to engage the occupant in a conversation with the building control system and the building engineer. Preliminary outcomes of the BA-enabled feedback loop are presented, and the effectiveness of the three display modes will be compared to other dashboard studies to baseline energy savings in future research.

  11. Impacts of Regional Electricity Prices and Building Type on the Economics of Commercial Photovoltaic Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ong, S.; Campbell, C.; Clark, N.

    2012-12-01

    To identify the impacts of regional electricity prices and building type on the economics of solar photovoltaic (PV) systems, 207 rate structures across 77 locations and 16 commercial building types were evaluated. Results for expected solar value are reported for each location and building type. Aggregated results are also reported, showing general trends across various impact categories.

  12. Healthy Building Design for the Commercial, Industrial, and Institutional Marketplace.

    Science.gov (United States)

    Turner, William A.

    Building design and construction that helps deliver both superior air quality and occupant thermal comfort, while minimizing energy consumption, are examined. The paper explores an integrated building systems approach that combines the principles of "directed air flow control" and "demand controlled ventilation" where ventilation is effectively…

  13. Scenario Analysis of Peak Demand Savings for Commercial Buildings with Thermal Mass in California

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Rongxin; Kiliccote, Sila; Piette, Mary Ann; Parrish, Kristen

    2010-05-14

    This paper reports on the potential impact of demand response (DR) strategies in commercial buildings in California based on the Demand Response Quick Assessment Tool (DRQAT), which uses EnergyPlus simulation prototypes for office and retail buildings. The study describes the potential impact of building size, thermal mass, climate, and DR strategies on demand savings in commercial buildings. Sensitivity analyses are performed to evaluate how these factors influence the demand shift and shed during the peak period. The whole-building peak demand of a commercial building with high thermal mass in a hot climate zone can be reduced by 30percent using an optimized demand response strategy. Results are summarized for various simulation scenarios designed to help owners and managers understand the potential savings for demand response deployment. Simulated demand savings under various scenarios were compared to field-measured data in numerous climate zones, allowing calibration of the prototype models. The simulation results are compared to the peak demand data from the Commercial End-Use Survey for commercial buildings in California. On the economic side, a set of electricity rates are used to evaluate the impact of the DR strategies on economic savings for different thermal mass and climate conditions. Our comparison of recent simulation to field test results provides an understanding of the DR potential in commercial buildings.

  14. Advanced Controls and Communications for Demand Response andEnergy Efficiency in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kiliccote, Sila; Piette, Mary Ann; Hansen, David

    2006-01-17

    Commercial buildings account for a large portion of summer peak demand. Research results show that there is significant potential to reduce peak demand in commercial buildings through advanced control technologies and strategies. However, a better understanding of commercial building's contribution to peak demand and the use of energy management and control systems is required to develop this demand response resource to its full potential. This paper discusses recent research results and new opportunities for advanced building control systems to provide demand response (DR) to improve electricity markets and reduce electric grid problems. The main focus of this paper is the role of new and existing control systems for HVAC and lighting in commercial buildings. A demand-side management framework from building operations perspective with three main features: daily energy efficiency, daily peak load management and event driven, dynamic demand response is presented. A general description of DR, its benefits, and nationwide potential in commercial buildings is outlined. Case studies involving energy management and control systems and DR savings opportunities are presented. The paper also describes results from three years of research in California to automate DR in buildings. Case study results and research on advanced buildings systems in New York are also presented.

  15. Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Torcellini, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bonnema, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sheppy, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Shanti [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.

  16. Commercial and Multifamily Building Tenant Energy Usage Aggregation and Privacy

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, Olga V.; Pulsipher, Trenton C.; Wang, Na

    2014-11-17

    In a number of cities and states, building owners are required to disclose and/or benchmark their building energy use. This requires the building owner to possess monthly whole-building energy usage information, which can be challenging for buildings in which individual tenants have their own utility meters and accounts with the utility. Some utilities and utility regulators have turned to aggregation of customer data as a way to give building owners the whole-building energy usage data while protecting customer privacy. However, no utilities or regulators appear to have conducted a concerted statistical, cybersecurity, and privacy analysis to justify the level of aggregation selected. Therefore, the Tennant Data Aggregation Task was established to help utilities address these issues and provide recommendations as well as a theoretical justification of the aggregation threshold. This study is focused on the use case of submitting data for ENERGY STAR Portfolio Manager (ESPM), but it also looks at other potential use cases for monthly energy consumption data.

  17. An analysis of heating and cooling conservation features in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, R.J.

    1990-12-31

    One purpose of this study is to estimate the relationship in commercial buildings between conservation investments, fuel prices, building occupancy and building characteristics for new buildings and for existing buildings. The database is a nationwide survey of energy in commercial buildings conducted by the Energy Information Administration (EIA) in 1906. Some simple cross-tabulations indicate that conservation measures vary with building size, building age, and fuel used for building heating. Regression estimates of a conservation model indicate that the number of conservation model indicate that the number of conservation features installed during construction is a positive function of the price of the heating fuel at the time of construction. Subsequent additions of conservation features are positively correlated with increases in heating fuel prices. Given the EIA projection of relatively stable future energy prices, the number of retrofits may not increase significantly. Also, energy efficiency in new buildings may not continue to increase relative to current new buildings. If fuel prices affect consumption via initial conservation investments, current fuel prices, marginal or average, are not the appropriate specification. The fuel price regression results indicate that conservation investments in new buildings are responsive to market signals. Retrofits are less responsive to market signals. The number of conservation features in a building is not statistically related to the type of occupancy (owner versus renter), which implies that conservation strategies are not impeded by the renting or leasing of buildings.

  18. An analysis of heating and cooling conservation features in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, R.J.

    1990-01-01

    One purpose of this study is to estimate the relationship in commercial buildings between conservation investments, fuel prices, building occupancy and building characteristics for new buildings and for existing buildings. The database is a nationwide survey of energy in commercial buildings conducted by the Energy Information Administration (EIA) in 1906. Some simple cross-tabulations indicate that conservation measures vary with building size, building age, and fuel used for building heating. Regression estimates of a conservation model indicate that the number of conservation model indicate that the number of conservation features installed during construction is a positive function of the price of the heating fuel at the time of construction. Subsequent additions of conservation features are positively correlated with increases in heating fuel prices. Given the EIA projection of relatively stable future energy prices, the number of retrofits may not increase significantly. Also, energy efficiency in new buildings may not continue to increase relative to current new buildings. If fuel prices affect consumption via initial conservation investments, current fuel prices, marginal or average, are not the appropriate specification. The fuel price regression results indicate that conservation investments in new buildings are responsive to market signals. Retrofits are less responsive to market signals. The number of conservation features in a building is not statistically related to the type of occupancy (owner versus renter), which implies that conservation strategies are not impeded by the renting or leasing of buildings.

  19. Small- and Medium-Sized Commercial Building Monitoring and Controls Needs: A Scoping Study

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas; Underhill, Ronald M.; Goddard, James K.; Taasevigen, Danny J.; Piette, M. A.; Granderson, J.; Brown, Rich E.; Lanzisera, Steven M.; Kuruganti, T.

    2012-10-31

    Buildings consume over 40% of the total energy consumption in the U.S. A significant portion of the energy consumed in buildings is wasted because of the lack of controls or the inability to use existing building automation systems (BASs) properly. Much of the waste occurs because of our inability to manage and controls buildings efficiently. Over 90% of the buildings are either small-size (<5,000 sf) or medium-size (between 5,000 sf and 50,000 sf); these buildings currently do not use BASs to monitor and control their building systems from a central location. According to Commercial Building Energy Consumption Survey (CBECS), about 10% of the buildings in the U.S. use BASs or central controls to manage their building system operations. Buildings that use BASs are typically large (>100,000 sf). Lawrence Berkeley National Laboratory (LBNL), Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL) were asked by the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP) to identify monitoring and control needs for small- and medium-sized commercial buildings and recommend possible solutions. This study documents the needs and solutions for small- and medium-sized buildings.

  20. The analysis of energy consumption of a commercial building in Tianjin, China

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Jing [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China)], E-mail: zhaojing@tju.edu.cn; Zhu Neng [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China); Wu Yong [Department of Science and Technology, Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China)

    2009-06-15

    According to statistics and field investigation, the energy consumption situation and reality of commercial building is described in this paper. As the first step of large-scale public building energy efficiency supervision system encouraged by central government of China, the energy consumption of several typical commercial buildings and public buildings was analyzed in detail. The main contents of investigation are as follows: basic information of building, operational record of energy consumption equipment, energy consumption of indoor equipments, energy-efficiency assessment of energy consumption systems and equipments, investigation of behavior energy saving, etc. On this basis further analysis and diagnosis including indoor thermal and humid environment, operation state of air-conditioning water system, operation state of air-conditioning duct system and operation management of air-conditioning system were implemented. The results show that the most energy consumption of buildings in this city is commercial buildings, which can reach to about 240 W/m{sup 2} per year. Further analysis tells that air conditioning systems play the major role of building energy consumption, and building energy saving has great potential in this city. In this paper, the ways of diagnosis work for building energy consumption are also described and discussed. Reasonable test, diagnosis and analysis are meaningful for building energy efficiency retrofit and management.

  1. The analysis of energy consumption of a commercial building in Tianjin, China

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jing; Zhu, Neng [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China); Wu, Yong [Department of Science and Technology, Ministry of Housing and Urban-Rural Development of the People' s Republic of China, Beijing 100835 (China)

    2009-06-15

    According to statistics and field investigation, the energy consumption situation and reality of commercial building is described in this paper. As the first step of large-scale public building energy efficiency supervision system encouraged by central government of China, the energy consumption of several typical commercial buildings and public buildings was analyzed in detail. The main contents of investigation are as follows: basic information of building, operational record of energy consumption equipment, energy consumption of indoor equipments, energy-efficiency assessment of energy consumption systems and equipments, investigation of behavior energy saving, etc. On this basis further analysis and diagnosis including indoor thermal and humid environment, operation state of air-conditioning water system, operation state of air-conditioning duct system and operation management of air-conditioning system were implemented. The results show that the most energy consumption of buildings in this city is commercial buildings, which can reach to about 240 W/m{sup 2} per year. Further analysis tells that air conditioning systems play the major role of building energy consumption, and building energy saving has great potential in this city. In this paper, the ways of diagnosis work for building energy consumption are also described and discussed. Reasonable test, diagnosis and analysis are meaningful for building energy efficiency retrofit and management. (author)

  2. Energy and Energy Cost Savings Analysis of the IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian; Athalye, Rahul A.; Hart, Philip R.; Rosenberg, Michael I.; Xie, YuLong; Goel, Supriya; Mendon, Vrushali V.; Liu, Bing

    2013-08-30

    The purpose of this analysis is to assess the relative energy and energy cost performance of commercial buildings designed to meet the requirements found in the commercial energy efficiency provisions of the International Energy Conservation Code (IECC). Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. As many states have historically adopted the IECC for both residential and commercial buildings, PNNL has evaluated the impacts of the commercial provisions of the 2006, 2009, and 2012 editions of the IECC. PNNL also compared energy performance with corresponding editions of ANSI/ASHRAE/IES Standard 90.1 to help states and local jurisdictions make informed decisions regarding model code adoption.

  3. Destruction of Spores on Building Decontamination Residue in a Commercial Autoclave▿

    OpenAIRE

    Lemieux, P.; Sieber, R; Osborne, A.; Woodard, A.

    2006-01-01

    The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently r...

  4. Destruction of Spores on Building Decontamination Residue in a Commercial Autoclave▿

    OpenAIRE

    Lemieux, P.; Sieber, R.; Osborne, A.; Woodard, A.

    2006-01-01

    The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently r...

  5. Energy Efficiency Trends in Residential and Commercial Buildings - August 2010

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2010-08-01

    This report overviews trends in the construction industry, including profiles of buildings and the resulting impacts on energy consumption. It begins with an executive summary of the key findings found in the body of the report, so some of the data and charts are replicated in this section. Its intent is to provide in a concise place key data points and conclusions. The remainder of the report provides a specific profile of the construction industry and patterns of energy use followed by sections providing product and market insights and information on policy efforts, such as taxes and regulations, which are intended to influence building energy use. Information on voluntary programs is also offered.

  6. DOE passive solar commercial buildings program: project summaries

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    The 23 projects participating in this program comprise a wide range of building types including offices, retail establishments, educational facilities, public service facilities, community and visitor centers, and private specialized-use facilities, located throughout the United States. Summary data and drawings are presented for each project. (MHR)

  7. Commercial Building Energy Asset Score Program Overview and Technical Protocol (Version 1.1)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na; Goel, Supriya; Makhmalbaf, Atefe

    2013-08-09

    The U.S. Department of Energy (DOE) is developing a voluntary national scoring system for commercial buildings to help building owners and managers assess a building’s energy-related systems independent of operations. The goal of the score is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system, known as the Commercial Building Energy Asset Score, will allow building owners and managers to compare their building infrastructure against peers and track building upgrades over time. The system will also help other building stakeholders (e.g., building investors, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset scoring tool. The alternative methods that were considered prior to developing the current approach are described in the Program Overview and Technical Protocol Version 1.0.

  8. New Construction for Commercial Building (Restaurant) By Considering The Green Building Strategies

    OpenAIRE

    MF Baharom; Ahmad, K.; M. N. M. Nasir; W.M Bukhari; H.I. Jaafar

    2015-01-01

    The Green Building Index (GBI) is one of green building strategies that are needed in order to decrease the human technologies and waste made by them. Moreover, GBI is the latest green building strategies that been implemented in the new building construction in Malaysia. It is proven as the building sector consumes 40% of the total energy consumption in the world, thus increasing the environmental problems. Mechanical, cooling, lighting and ventilating spaces consume by far the most energy i...

  9. Development of an Online Toolkit for Measuring Commercial Building Energy Efficiency Performance -- Scoping Study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na

    2013-03-13

    This study analyzes the market needs for building performance evaluation tools. It identifies the existing gaps and provides a roadmap for the U.S. Department of Energy (DOE) to develop a toolkit with which to optimize energy performance of a commercial building over its life cycle.

  10. Development of whole-building energy design targets for commercial buildings: Phase 1, Planning: Volume 1, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Crawley, D.B.; Briggs, R.S.; Jones, J.W.; Seaton, W.W.; Kaufman, J.E.; Deringer, J.J.; Kennett, E.W.

    1987-04-01

    This report describes background research for preparation of a plan for development of whole-building energy targets for new commercial buildings. The lead laboratory for this program is the Pacific Northwest Laboratory. A wide variety of expertise and resources from industry, academia, other government entities, and other DOE laboratories are used in planning, reviewing and conducting research activities. Cooperative and complementary research development, and technology transfer activities with other interested organizations are actively pursued.

  11. SUPERVISORY CONTROL FOR PEAK REDUCTION IN COMMERCIAL BUILDINGS WHILE MAINTAINING COMFORT

    Energy Technology Data Exchange (ETDEWEB)

    Nutaro, James J [ORNL; Olama, Mohammed M [ORNL; Kuruganti, Teja [ORNL

    2016-01-01

    This paper describes a supervisory control strategy for limiting peak power demand by small and medium commercial buildings while still meeting the business needs of the occupants. This control strategy has two features that make it relevant to new and existing buildings. First, it is designed to operate with building equipment, such as air conditioning and refrigeration systems, as they are presently installed in most small and medium commercial buildings. Because of this, the supervisory control could be realized as a software-only retrofit to existing building management systems. Second, the proposed control acts as a supervisory management layer over existing control systems, rather than replacing them outright. The primary idea of this approach is that the controls for individual building equipment request energy resources for a control action and the supervisory control examines the requests and decides which control actions to allow while satisfying a limit on peak power demand.

  12. Commercial Building Loads Providing Ancillary Services in PJM

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, Jason; Kiliccote, Sila; Boch, Jim; Chen, Jonathan; Nawy, Robert

    2014-06-27

    The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

  13. India Commercial Buildings Data Framework: A Summary of Potential Use Cases

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, Paul,; Mathew, Sangeeta; Kumar, Satish; Singh, Mohini; Stratton, Hannah; Iyer, Maithili

    2017-09-06

    This report details a potential set of use cases for India’s Commercial Buildings Data Framework. The use cases are aimed at enabling data-driven, evidence-based policy making and at transforming the market for energy efficiency in the building sector by facilitating the adoption of (1) superior energy-efficient building design and operation and maintenance practices, and (2) better specification and procurement of end-use equipment and systems.

  14. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Ahlfeldt, Christopher [Navigant Consulting, Inc., Burlington, MA (United States); Hiraiwa, Hirokazu [Navigant Consulting, Inc., Burlington, MA (United States); Sathe, Amul [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States)

    2009-12-01

    This study characterizes and assesses the appliances used in commercial buildings. The primary objectives of this study were to document the energy consumed by commercial appliances and identify research, development and demonstration (RD&D) opportunities for efficiency improvements, excluding product categories such as HVAC, building lighting, refrigeration equipment, and distributed generation systems. The study included equipment descriptions, characteristics of the equipment’s market, national energy consumption, estimates of technical potential for energy-saving technologies, and recommendations for U.S. Department of Energy programs that can promote energy savings in commercial appliances.

  15. Energy Code Compliance in a Detailed Commercial Building Sample: The Effects of Missing Data

    Energy Technology Data Exchange (ETDEWEB)

    Biyani, Rahul K.; Richman, Eric E.

    2003-09-30

    Most commercial buildings in the U.S. are required by State or local jurisdiction to meet energy standards. The enforcement of these standards is not well known and building practice without them on a national scale is also little understood. To provide an understanding of these issues, a database has been developed at PNNL that includes detailed energy related building characteristics of 162 commercial buildings from across the country. For this analysis, the COMcheck? compliance software (developed at PNNL) was used to assess compliance with energy codes among these buildings. Data from the database for each building provided the program input with percentage energy compliance to the ASHRAE/IESNA Standard 90.1-1999 energy as the output. During the data input process it was discovered that some essential data for showing compliance of the building envelope was missed and defaults had to be developed to provide complete compliance information. This need for defaults for some data inputs raised the question of what the effect on documenting compliance could be due to missing data. To help answer this question a data collection effort was completed to assess potential differences. Using the program Dodge View, as much of the missing envelope data as possible was collected from the building plans and the database input was again run through COMcheck?. The outputs of both compliance runs were compared to see if the missing data would have adversely affected the results. Both of these results provided a percentage compliance of each building in the envelope and lighting categories, showing by how large a percentage each building either met or fell short of the ASHRAE/IESNA Standard 90.1-1999 energy code. The results of the compliance runs showed that 57.7 % of the buildings met or exceeded envelope requirements with defaults and that 68 % met or exceeded envelope requirements with the actual data. Also, 53.6 % of the buildings met or surpassed the lighting requirements

  16. Job/Task Analysis: Enhancing the Commercial Building Workforce Through the Development of Foundational Materials; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Studer, D.; Kemkar, S.

    2012-09-01

    For many commercial building operation job categories, industry consensus has not been reached on the knowledge, skills, and abilities that practitioners should possess. The goal of this guidance is to help streamline the minimum competencies taught or tested by organizations catering to building operations and maintenance personnel while providing a basis for developing and comparing new and existing training programs in the commercial building sector. The developed JTAs will help individuals identify opportunities to enhance their professional skills, enable industry to identify an appropriately skilled workforce, and allow training providers to ensure that they are providing the highest quality product possible.

  17. Final Technical Report for the Net-Zero Energy Commercial Buildings Consortium

    Energy Technology Data Exchange (ETDEWEB)

    Fazeli, Sandy [National Association of State Energy Officials, Arlington, VA (United States)

    2014-09-30

    The Commercial Buildings Consortium (CBC) was established in 2009, under the chairmanship of the National Association of State Energy Officials (NASEO), as a supporting organization to the Commercial Buildings Initiative (CBI). The CBI was created by Congress through the Energy Independence and Security Act of 2007 (EISA) and launched by the Department of Energy (DOE) in 2008 with the goal to “develop and disseminate technologies, practices, and policies for establishment of zero net energy commercial buildings.”. The impact of the CBC since 2009 has been multifold, resulting in increased collaboration, increased innovation, and increased demonstration and deployment. During the project performance period of 2009-2014, the CBC provided an organizational framework for sustained public-private collaboration among more than 600 commercial building professionals, researchers and educators, utilities, and government agencies at federal, state, and local level. The CBC’s research has identified emerging technologies, market strategies, and innovative public and corporate policies to help advance CBI’s zero-net-energy. Finally, the CBC worked in close partnership with DOE’s commercial building teams and the Better Buildings Alliances to identify opportunities for proving out and deploying energy-saving technologies and practices.

  18. Energy Efficiency Potential in Existing Commercial Buildings: Review of Selected Recent Studies

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, David B.

    2009-04-03

    This report reviews six recent studies (from 2002 through 2006) by states and utilities to assess the energy saving potential in existing commercial buildings. The studies cover all or portions of California, Connecticut, Vermont, Colorado, Illinois, and the Pacific Northwest. The studies clearly reveal that lighting remains the single largest and most cost effective end use that can be reduced to save energy. Overall the study indicated that with existing technologies and costs, a reasonable range of economic savings potential in existing commercial buildings is between 10 and 20 percent of current energy use. While not a focus of the study, an additional conclusion is that implementation of commercial building monitoring and controls would also play an important role in the nation’s efforts to improve energy efficiency of existing buildings.

  19. The potential for PVs in Greek commercial buildings

    Science.gov (United States)

    Samouil, Chris

    The photovoltaic sector has been growing explosively, worldwide, for the past few years. At present, grid-connected installations dominate the world market. The photovoltaic technology, types of systems, applications and the market of PVs are presented, placing emphasis on installations regarding the building sector. The main focus of the project is concentrated on Greece. The fact that Greece has favourable natural conditions for the exploitation of solar energy, coupled with the support scheme on phototovoltaics introduced with the new law on renewable energy sources voted in June 2006, makes it very interesting to invest in the Greek PV market. Using a newly built office building in Athens with a roof-top PV installation as a case study, this project looks at the viability of grid-connected systems in the building sector. The annual energy output of the system and CO2 emissions reduction were modelled. Embodied energy, installation cost and annual savings were also considered to determine payback periods. The economic payback period of the system was found to be shorter than its lifetime at 16.2 years, reducing to 9.7 years when grants were included. The carbon payback period was calculated at 6.3 years. A sensitivity analysis on the effect of different factors affecting the viability of the PV installation was carried out. Assuming constant electricity rate increases or a more favourable location for the project the results are more attractive. The same case study in Crete would have a payback period reduced by almost 20% compared to that in Athens. A method to extrapolate the findings for the whole building sector of Attica is proposed as a future research project. As an indication it is found that 60,000 similar to the base case roof-top PV systems can produce around 3.1% of the country's thermally produced electricity and save 0.9% of its CO2 emissions. Finally, the strengths and weeknesses of the new RES law are identified and suggestions are made in order

  20. Rationale for Measuring Duct Leakage Flows in Large Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.; Diamond, Richard C.; Sherman, Max H.

    2005-07-01

    Industry-wide methods of assessing duct leakage are based on duct pressurization tests, and focus on ''high pressure'' ducts. Even though ''low pressure'' ducts can be a large fraction of the system and tend to be leaky, few guidelines or construction specifications require testing these ducts. We report here on the measured leakage flows from ten large commercial duct systems at operating conditions: three had low leakage (less than 5% of duct inlet flow), and seven had substantial leakage (9 to 26%). By comparing these flows with leakage flows estimated using the industry method, we show that the latter method by itself is not a reliable indicator of whole-system leakage flow, and that leakage flows need to be measured.

  1. Building a Relationship between Robot Characteristics and Teleoperation User Interfaces.

    Science.gov (United States)

    Mortimer, Michael; Horan, Ben; Seyedmahmoudian, Mehdi

    2017-03-14

    The Robot Operating System (ROS) provides roboticists with a standardized and distributed framework for real-time communication between robotic systems using a microkernel environment. This paper looks at how ROS metadata, Unified Robot Description Format (URDF), Semantic Robot Description Format (SRDF), and its message description language, can be used to identify key robot characteristics to inform User Interface (UI) design for the teleoperation of heterogeneous robot teams. Logical relationships between UI components and robot characteristics are defined by a set of relationship rules created using relevant and available information including developer expertise and ROS metadata. This provides a significant opportunity to move towards a rule-driven approach for generating the designs of teleoperation UIs; in particular the reduction of the number of different UI configurations required to teleoperate each individual robot within a heterogeneous robot team. This approach is based on using an underlying rule set identifying robots that can be teleoperated using the same UI configuration due to having the same or similar robot characteristics. Aside from reducing the number of different UI configurations an operator needs to be familiar with, this approach also supports consistency in UI configurations when a teleoperator is periodically switching between different robots. To achieve this aim, a Matlab toolbox is developed providing users with the ability to define rules specifying the relationship between robot characteristics and UI components. Once rules are defined, selections that best describe the characteristics of the robot type within a particular heterogeneous robot team can be made. A main advantage of this approach is that rather than specifying discrete robots comprising the team, the user can specify characteristics of the team more generally allowing the system to deal with slight variations that may occur in the future. In fact, by using the

  2. Building a Relationship between Robot Characteristics and Teleoperation User Interfaces

    Directory of Open Access Journals (Sweden)

    Michael Mortimer

    2017-03-01

    Full Text Available The Robot Operating System (ROS provides roboticists with a standardized and distributed framework for real-time communication between robotic systems using a microkernel environment. This paper looks at how ROS metadata, Unified Robot Description Format (URDF, Semantic Robot Description Format (SRDF, and its message description language, can be used to identify key robot characteristics to inform User Interface (UI design for the teleoperation of heterogeneous robot teams. Logical relationships between UI components and robot characteristics are defined by a set of relationship rules created using relevant and available information including developer expertise and ROS metadata. This provides a significant opportunity to move towards a rule-driven approach for generating the designs of teleoperation UIs; in particular the reduction of the number of different UI configurations required to teleoperate each individual robot within a heterogeneous robot team. This approach is based on using an underlying rule set identifying robots that can be teleoperated using the same UI configuration due to having the same or similar robot characteristics. Aside from reducing the number of different UI configurations an operator needs to be familiar with, this approach also supports consistency in UI configurations when a teleoperator is periodically switching between different robots. To achieve this aim, a Matlab toolbox is developed providing users with the ability to define rules specifying the relationship between robot characteristics and UI components. Once rules are defined, selections that best describe the characteristics of the robot type within a particular heterogeneous robot team can be made. A main advantage of this approach is that rather than specifying discrete robots comprising the team, the user can specify characteristics of the team more generally allowing the system to deal with slight variations that may occur in the future. In fact, by

  3. Commercial applications of speech interface technology: an industry at the threshold.

    Science.gov (United States)

    Oberteuffer, J A

    1995-10-24

    Speech interface technology, which includes automatic speech recognition, synthetic speech, and natural language processing, is beginning to have a significant impact on business and personal computer use. Today, powerful and inexpensive microprocessors and improved algorithms are driving commercial applications in computer command, consumer, data entry, speech-to-text, telephone, and voice verification. Robust speaker-independent recognition systems for command and navigation in personal computers are now available; telephone-based transaction and database inquiry systems using both speech synthesis and recognition are coming into use. Large-vocabulary speech interface systems for document creation and read-aloud proofing are expanding beyond niche markets. Today's applications represent a small preview of a rich future for speech interface technology that will eventually replace keyboards with microphones and loud-speakers to give easy accessibility to increasingly intelligent machines.

  4. End-use energy consumption estimates for US commercial buildings, 1989

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D.B.; Wrench, L.E.; Marsh, T.L. [Pacific Northwest Lab., Richland, WA (United States)

    1993-11-01

    An accurate picture of how energy is used in the nation`s stock of commercial buildings can serve a variety of program planning and policy needs within the Department of Energy, by utilities, and other groups seeking to improve the efficiency of energy use in the building sector. This report describes an estimation of energy consumption by end use based upon data from the 1989 Commercial Building Energy Consumption Survey (CBECS). The methodology used in the study combines elements of engineering simulations and statistical analysis to estimate end-use intensities for heating, cooling, ventilation, lighting, refrigeration, hot water, cooking, and miscellaneous equipment. Billing data for electricity and natural gas were first decomposed into weather and nonweather dependent loads. Subsequently, Statistical Adjusted Engineering (SAE) models were estimated by building type with annual data. The SAE models used variables such as building size, vintage, climate region, weekly operating hours, and employee density to adjust the engineering model predicted loads to the observed consumption. End-use consumption by fuel was estimated for each of the 5,876 buildings in the 1989 CBECS. The report displays the summary results for eleven separate building types as well as for the total US commercial building stock.

  5. Load shape development for Swedish commercial and public buildings - methodologies and results

    Energy Technology Data Exchange (ETDEWEB)

    Noren, C.

    1999-06-01

    The knowledge concerning electricity consumption, and especially load demand, in Swedish commercial buildings is very limited. The current study deals with methods for electricity consumption indicator development and application of the different methodologies on measured data. Typical load shapes and consumption indicators are developed for four different types of commercial buildings: schools, hotels, grocery stores and department stores. Two different methodologies for consumption indicator development are presented and discussed. The influence on load demand from different factors such as, installations, outdoor temperature and building activities is studied. It is suggested that building floor area is not an accurate determinant of building electricity consumption and it is necessary to consider other factors as those just mentioned to understand commercial building electricity consumption. The application of the two methodologies on measured data shows that typical load shapes can be developed with reasonable accuracy. For most of the categories it is possible to use the typical load shapes for approximation of whole-building load shapes with error rates about 10-25% depending on day-type and building type. Comparisons of the developed load shapes with measured data show good agreement 49 refs, 22 figs, 3 tabs

  6. End-use energy consumption estimates for U.S. commercial buildings, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D.B.; Wrench, L.E.

    1997-03-01

    An accurate picture of how energy is used in the nation`s stock of commercial buildings can serve a variety of program planning and policy needs of the US Department of Energy, utilities, and other groups seeking to improve the efficiency of energy use in the building sector. This report describes an estimation of energy consumption by end use based upon data from the 1992 Commercial Building Energy Consumption Survey (CBECS). The methodology used in the study combines elements of engineering simulations and statistical analysis to estimate end-use intensities for heating, cooling, ventilation, lighting, refrigeration, hot water, cooking, and miscellaneous equipment. Statistical Adjusted Engineering (SAE) models were estimated by building type. The nonlinear SAE models used variables such as building size, vintage, climate region, weekly operating hours, and employee density to adjust the engineering model predicted loads to the observed consumption (based upon utility billing information). End-use consumption by fuel was estimated for each of the 6,751 buildings in the 1992 CBECS. The report displays the summary results for 11 separate building types as well as for the total US commercial building stock. 4 figs., 15 tabs.

  7. Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions for Buildings in 2016 and Later

    Energy Technology Data Exchange (ETDEWEB)

    Deru, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Field-Macumber, Kristin [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code (IRC) enacted in Section 1331 of the 2005 Energy Policy Act (EPAct) of 2005, noted in Internal Revenue Service (IRS) Notices 2006-52 (IRS 2006), 2008-40 (IRS 2008) and 2012-26 (IRS 2012), and updated by the Protecting Americans from Tax Hikes (PATH) Act of 2015. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning (HVAC); and service hot water (SHW) systems. This document applies to buildings placed in service on or after January 1, 2016.

  8. Project Management Plan/Progress Report UT/GTKS Training Program Development for Commercial Building Operators

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2013-03-31

    Universidad del Turabo (UT), in a collaborative effort with Global Turn Key Services, Inc. (GTKS), proposed to develop a training program and a commercialization plan for the development of Commercial Building Operators (CBOs). The CBOs will operate energy efficient buildings to help maintain existing buildings up to their optimal energy performance level, and ensure that net-zero-energy buildings continuously operate at design specifications, thus helping achieve progress towards meeting BTP Strategic Goals of creating technologies and design approaches that enable net-zero-energy buildings at low incremental costs by 2025. The proposed objectives were then: (1) Develop a Commercial Building Operator (CBO) training program and accreditation that will in turn provide a certification to participants recognized by Accreditation Boards such as the North American Board of Certified Energy Practitioners (NABCEP) and Leadership in Energy & Environmental Designs (LEED). (2) Develop and implement a commercialization and sustainability plan that details marketing, deployment, financial characterization, job placement, and other goals required for long-term sustainability of the project after the funding period. (3) After program development and deployment, provide potential candidates with the knowledge and skill sets to obtain employment in the commercial building green energy (net-zero-energy building) job market. The developed CBO training program will focus on providing skills for participants, such as displaced and unemployed workers, to enter the commercial building green energy (net-zeroenergy building) job market. This course was designed to allow a participant with minimal to no experience in commercial building green technology to obtain the required skill sets to enter the job market in as little as 12 weeks of intensive multi-faceted learning. After completion of the course, the CBO staff concluded the participant will meet minimum established accreditation

  9. Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California.

    Science.gov (United States)

    Bennett, D H; Fisk, W; Apte, M G; Wu, X; Trout, A; Faulkner, D; Sullivan, D

    2012-08-01

    This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale. © 2012 John Wiley & Sons A/S.

  10. Ventilation Relevant Contaminants of Concern in Commercial Buildings Screening Process and Results

    Energy Technology Data Exchange (ETDEWEB)

    Parthasarathy, Srinandini [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); McKone, Thomas E. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); Apte, Michael G. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)

    2011-04-29

    This report summarizes the screening procedure and its results for selecting contaminants of concern (COC), whose concentrations are affected by ventilation in commercial buildings. Many pollutants comprising criteria pollutants, volatile organic compounds (VOCs), semi-volatile organic compounds (SVOCs) and biological contaminants are found in commercial buildings. In this report, we focus primarily on identifying potential volatile organic COC, which are impacted by ventilation. In the future we plan to extend this effort to inorganic gases and particles. Our screening considers compounds detected frequently in indoor air and compares the concentrations to health-guidelines and thresholds. However, given the range of buildings under consideration, the contaminant sources and their concentrations will vary depending on the activity and use of the buildings. We used a literature review to identify a large list of chemicals found in commercial-building indoor air. The VOCs selected were subject to a two stage screening process, and the compounds of greater interest are included in priority List A. Other VOCs that have been detected in commercial buildings are included in priority List B. The compounds in List B, were further classified into groups B1, B2, B3, B4 in order of decreasing interest.

  11. Health effects associated with energy conservation measures in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, R.D.; Baechler, M.C.

    1990-09-01

    Indoor air quality can be impacted by hundreds of different chemicals. More than 900 different organic compounds alone have been identified in indoor air. Health effects that could arise from exposure to individual pollutants or mixtures of pollutants cover the full range of acute and chronic effects, including largely reversible responses, such as rashes and irritations, to the irreversible toxic and carcinogenic effects. These indoor contaminants are emitted from a large variety of materials and substances that are widespread components of everyday life. Pacific Northwest Laboratory conducted a search of the peer-reviewed literature on health effects associated with indoor air contaminants for the Bonneville Power Administration to aid the agency in the preparation of environmental documents. Results are reported in two volumes. Volume 1 summarizes the results of the search of the peer-reviewed literature on health effects associated with a selected list of indoor air contaminants. In addition, the report discusses potential health effects of polychlorinated biphenyls and chlorofluorocarbons. All references to the literature reviewed are found in this document Volume 2. Volume 2 provides detailed information from the literature reviewed, summarizes potential health effects, reports health hazard ratings, and discusses quantitative estimates of carcinogenic risk in humans and animals. Contaminants discussed in this report are those that; have been measured in the indoor air of a public building; have been measured (significant concentrations) in test situations simulating indoor air quality (as presented in the referenced literature); and have a significant hazard rating. 38 refs., 7 figs., 23 tabs.

  12. Indoor air quality issues related to the acquisition of conservation in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, M.C.; Hadley, D.L.; Marseille, T.J.

    1990-09-01

    The quality of indoor air in commercial buildings is dependent on the complex interaction between sources of indoor pollutants, environmental factors within buildings such as temperature and humidity, the removal of air pollutants by air-cleaning devices, and the removal and dilution of pollutants from outside air. To the extent that energy conservation measures (ECMs) may affect a number of these factors, the relationship between ECMs and indoor air quality is difficult to predict. Energy conservation measures may affect pollutant levels in other ways. Conservation measures, such as caulking and insulation, may introduce sources of indoor pollutants. Measures that reduce mechanical ventilation may allow pollutants to build up inside structures. Finally, heating, ventilation, and air-conditioning (HVAC) systems may provide surface areas for the growth of biogenic agents, or may encourage the dissemination of pollutants throughout a building. Information about indoor air quality and ventilation in both new and existing commercial buildings is summarized in this report. Sick building syndrome and specific pollutants are discussed, as are broader issues such as ventilation, general mitigation techniques, and the interaction between energy conservation activities and indoor air quality. Pacific Northwest Laboratory (PNL) prepared this review to aid the Bonneville Power Administration (Bonneville) in its assessment of potential environmental effects resulting from conservation activities in commercial buildings. 76 refs., 2 figs., 19 tabs.

  13. Nationwide Analysis of U.S. Commercial Building Solar Photovoltaic (PV) Breakeven Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gagnon, Pieter [National Renewable Energy Lab. (NREL), Golden, CO (United States); Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    The commercial sector offers strong potential for solar photovoltaics (PV) owing to abundant available roof space suitable for PV and the opportunity to offset the sector's substantial retail electricity purchases. This report evaluated the breakeven price of PV for 15 different building types and various financing options by calculating electricity savings based on detailed rate structures for most U.S. utility territories (representing approximately two thirds of U.S. commercial customers). We find that at current capital costs, an estimated 1/3 of U.S. commercial customers break even in the cash scenario and approximately 2/3 break even in the loan scenario. Variation in retail rates is a stronger driver of breakeven prices than is variation in building load or solar generation profiles. At the building level, variation in the average breakeven price is largely driven by the ability for a PV system to reduce demand charges.

  14. Miscellaneous equipment in commercial buildings: The inventory, utilization, and consumption by equipment type

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, R.G.; Williamson, M.A.; Richman, E.E.

    1990-09-01

    The nature of the miscellaneous equipment (devices other than permanently installed lighting and those used for space conditioning) in commercial buildings is diverse, comprising a wide variety of devices that are subject to varied patterns of use. This portion of the commercial load is frequently underestimated, and widely hypothesized to be growing. These properties make it a particularly difficult load to characterize for purposes of demand-side management. In the End-Use Load and Consumer Assessment Program (ELCAP), over 100 commercial sites in the Pacific Northwest have been metered at the end-use level for several years. Detailed inspections of the equipment in them have also been conducted. This paper describes how the ELCAP data have been used to estimate three fundamental properties of the various types of equipment in several classes of commercial buildings: (1) the installed capacity per unit floor area, (2) utilization of the equipment relative to the installed capacity, and (3) the resulting energy consumption by building type and for the Pacific Northwest commercial sector as a whole. Applications for the results include assessment of conservation potential, prediction of equipment loads from survey data, estimating equipment loads for energy audits, targeting of conservation technology development, and disaggregating building total or mixed end-use data. 4 tabs., refs.

  15. Expansion of the residential conservation service program to multi-family and small commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-11-01

    Alternative regulatory provisions are considered which might permit achievement of the building energy conservation regulatory goals at a lower cost. Major issues, regulatory and legislative options, and cost-benefit analyses are discussed for multi-family and commercial buildings. The following are presented: related government programs, urban and community impact analysis, institutional impacts, energy cost, Residential Conservation Service coverage, methods of analysis, and regional studies. (MHR)

  16. Analysis of variables that influence electric energy consumption in commercial buildings in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, M.M.Q. [Technical Drawing Department, Fluminense Federal University, Niteroi, Rio de Janeiro (Brazil); Energy Planning Program, Alberto Luiz Coimbra Institute for Research and Graduate Studies in Engineering - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); La Rovere, E.L. [Energy Planning Program, Alberto Luiz Coimbra Institute for Research and Graduate Studies in Engineering - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Goncalves, A.C.M. [Program for Graduate Studies in Architecture, School of Architecture and Urbanism, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2010-12-15

    Air conditioning systems in commercial buildings in Brazil are responsible for about 70% share of their energy consumption. According to BEN 2009 (The Brazilian Energy Balance), energy consumption in the residential, commercial and public sectors, where most buildings are found, represents 9.3% of the final energy consumption in Brazil. This paper aims to examine design factors that could contribute to greater reductions of electric energy consumption in commercial buildings, with emphasis on air conditioning. Simulations were carried out using shades and different types of glass, walls, flooring and roofing. The VisualDOE 2.61 was used as a simulation tool for calculating energy consumption of the analyzed building. This paper shows that the energy performance of the building is considerably influenced by the facade protection and shows, through tables, the impact that decisions related to the top-level and facades have on the energy consumption of the building. The authors concluded that the results confirm the importance of taking energy use into account in the very first design stages of the project, since appropriate choices of types of glass, external shading and envelope materials have a significant impact on energy consumption. (author)

  17. Maintenance of Vinyl Asbestos and Asphalt Tile Floors in Institutional, Industrial and Commercial Buildings.

    Science.gov (United States)

    Asphalt and Vinyl Asbestos Tile Inst., New York, NY.

    The claim is made that proper planning and modest outlays of time, labor, and material costs can provide and maintain a high appearance level for floors in institutional, commercial, and industrial buildings. Instructions for four basic steps in maintaining the good looks of vinyl asbestos and asphalt tile floors are treated in the booklet--(1)…

  18. A PILOT STUDY OF THE ACCURACY OF CO2 SENSORS IN COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

    2007-09-01

    Carbon dioxide (CO2) sensors are often deployed in commercial buildings to obtain CO2 data that are used to automatically modulate rates of outdoor air supply. The goal is to keep ventilation rates at or above design requirements and to save energy by avoiding ventilation rates exceeding design requirements. However, there have been many anecdotal reports of poor CO2 sensor performance in actual commercial building applications. This study evaluated the accuracy of 44 CO2 sensors located in nine commercial buildings to determine if CO2 sensor performance, in practice, is generally acceptable or problematic. CO2 measurement errors varied widely and were sometimes hundreds of parts per million. Despite its small size, this study provides a strong indication that the accuracy of CO2 sensors, as they are applied and maintained in commercial buildings, is frequently less than needed to measure typical values of maximum one-hour-average indoor-outdoor CO2 concentration differences with less than a 20percent error. Thus, we conclude that there is a need for more accurate CO2 sensors and/or better sensor maintenance or calibration procedures.

  19. 浅谈关于商业建筑的设计%Design of Commercial Buildings

    Institute of Scientific and Technical Information of China (English)

    王凯

    2011-01-01

    商业活动是以追求利润为目的,综合性是现代商业建筑的发展趋势,建筑师在设计商业建筑的方式和作用都发生了改变,不同的策划定位,商业特色和地方人文都影响着商业建筑的模式,设计合理,合情,合适的商业建筑,能够创造良好的社会和经济效益。%Business activities are based on profit for the purpose of integrated development of the modern trend of commercial buildings, architects design approach and the role of commercial buildings have changed, different planning position, business and local cultural characteristics all affect the pattern of commercial buildings, the design is reasonable, sensible, appropriate commercial buildings, to create a good social and economic benefits.

  20. Development of whole-building energy design targets for commercial buildings: Phase 1, Planning: Volume 2, Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Crawley, D.B.; Briggs, R.S.; Jones, J.W.; Seaton, W.W.; Kaufman, J.E.; Deringer, J.J.; Kennett, E.W.

    1987-08-01

    This is the second volume of the Phase 1 report and discusses the 10 tasks performed in Phase 1. The objective of this research is to develop a methodology for setting energy design targets to provide voluntary guidelines for the buildings industry. The whole-building energy targets project is being conducted at the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE) to encourage the construction of energy-efficient buildings by informing designers and owners about cost-effective goals for energy use in new commercial buildings. The outcome of this research will be a flexible methodology for setting such targets. The tasks are listed and discussed in this report as follows: Task 1 - Develop Detailed Project Goals and Objectives; Task 2 - Establish Buildings-Industry Liaison; Task 3 - Develop Approaches to the Energy Targets Model, Building Operations, and Climate; Task 4 - Develop an Approach for Treating Economic Considerations; Task 5 - Develop an Approach for Treating Energy Sources; Task 6 - Collect Energy-Use Data; Task 7 - Survey Energy Expert Opinion; Task 8 - Evaluation Procedure Specification and Integration; Task 9 - Phase 1 Report Development; and Task 10 - Phase 1 Review Planning.

  1. Better Building Alliance, Plug and Process Loads in Commercial Buildings: Capacity and Power Requirement Analysis (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    This brochure addresses gaps in actionable knowledge that can help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. This brochure should be used to make these decisions so systems can operate more energy efficiently; upfront capital costs will also decrease. This information can also be used to drive changes in negotiations about PPL energy demands. It should enable brokers and tenants to agree about lower PPL capacities. Owner-occupied buildings will also benefit. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems.

  2. Building user interfaces with Google Web Toolkit: usage properties analysis

    OpenAIRE

    Poklukar, Matej

    2012-01-01

    This Bachelor thesis provides an overview of different techniques used for web pages or web applications user interface development using Google Web Toolkit. During development process programmer and designer encounter the problem in which way should design be passed from designer to programmer. Designer can plot web page design easily on paper or in an appropriate program and sends it to the programmer. Or he can create design in more advanced form, as a multitude of different files. Prog...

  3. Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kiliccote, Sila; Piette, Mary Ann; Mathieu, Johanna; Parrish, Kristen

    2010-05-14

    California is a leader in automating demand response (DR) to promote low-cost, consistent, and predictable electric grid management tools. Over 250 commercial and industrial facilities in California participate in fully-automated programs providing over 60 MW of peak DR savings. This paper presents a summary of Open Automated DR (OpenADR) implementation by each of the investor-owned utilities in California. It provides a summary of participation, DR strategies and incentives. Commercial buildings can reduce peak demand from 5 to 15percent with an average of 13percent. Industrial facilities shed much higher loads. For buildings with multi-year savings we evaluate their load variability and shed variability. We provide a summary of control strategies deployed, along with costs to install automation. We report on how the electric DR control strategies perform over many years of events. We benchmark the peak demand of this sample of buildings against their past baselines to understand the differences in building performance over the years. This is done with peak demand intensities and load factors. The paper also describes the importance of these data in helping to understand possible techniques to reach net zero energy using peak day dynamic control capabilities in commercial buildings. We present an example in which the electric load shape changed as a result of a lighting retrofit.

  4. General Electric Company proposed demonstration Projects Matrix, commercial buildings, National Solar Demonstration Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-04-01

    The requirements for selecting commercial demonstrations are derived from the overall goal of the Federal program as stated in the ''National Program for Solar Heating and Cooling,'' ERDA 23-A, October 1975. This goal is to stimulate an industrial and commercial capability for producing and distributing solar heating and cooling (SHAC) systems. The development of the demonstration matrix consists of establishing selection criteria and developing a methodology for applying and evaluating these criteria. The output of this procedure results in a time phased matrix of location, SHAC systems, and building types which comprise the recommended National Solar Demonstration projects for commercial buildings. The Demonstration Matrix Definition is comprised of three principle elements: Demonstration identification; Specific Demonstration selection criteria; and Architect/Engineer (A/E) selection. (WDM)

  5. Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Stephen; Heaney, Michael; Jin, Xin; Robertson, Joseph; Cheung, Howard; Elmore, Ryan; Henze, Gregor

    2016-08-01

    Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energy models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.

  6. Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Stephen; Heaney, Michael; Jin, Xin; Robertson, Joseph; Cheung, Howard; Elmore, Ryan; Henze, Gregor

    2016-08-26

    Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energy models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.

  7. Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na; Gorrissen, Willy J.

    2013-01-11

    The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.

  8. Evaluation of different EEG acquisition systems concerning their suitability for building a brain-computer interface

    Directory of Open Access Journals (Sweden)

    Andreas Pinegger

    2016-09-01

    Full Text Available One important aspect in non-invasive brain-computer interface (BCI research is to acquire the electroencephalogram (EEG in a proper way. From an end-user perspective this means with maximum comfort and without any extra inconveniences (e.g., washing the hair. Whereas from a technical perspective, the signal quality has to be optimal to make the BCI work effectively and efficiently.In this work we evaluated three different commercially available EEG acquisition systems that differ in the type of electrode (gel-, water-, and dry-based, the amplifier technique, and the data transmission method. Every system was tested regarding three different aspects, namely, technical, BCI effectiveness and efficiency (P300 communication and control, and user satisfaction (comfort.We found that the water-based system had the lowest short circuit noise level, the hydrogel-based system had the highest P300 spelling accuracies, and the dry electrode system caused the least inconveniences.Therefore, building a reliable BCI is possible with all evaluated systems and it is on the user to decide which system meets the given requirements best.

  9. Optimization and Performance Study of Select Heating Ventilation and Air Conditioning Technologies for Commercial Buildings

    Science.gov (United States)

    Kamal, Rajeev

    Buildings contribute a significant part to the electricity demand profile and peak demand for the electrical utilities. The addition of renewable energy generation adds additional variability and uncertainty to the power system. Demand side management in the buildings can help improve the demand profile for the utilities by shifting some of the demand from peak to off-peak times. Heating, ventilation and air-conditioning contribute around 45% to the overall demand of a building. This research studies two strategies for reducing the peak as well as shifting some demand from peak to off-peak periods in commercial buildings: 1. Use of gas heat pumps in place of electric heat pumps, and 2. Shifting demand for air conditioning from peak to off-peak by thermal energy storage in chilled water and ice. The first part of this study evaluates the field performance of gas engine-driven heat pumps (GEHP) tested in a commercial building in Florida. Four GEHP units of 8 Tons of Refrigeration (TR) capacity each providing air-conditioning to seven thermal zones in a commercial building, were instrumented for measuring their performance. The operation of these GEHPs was recorded for ten months, analyzed and compared with prior results reported in the literature. The instantaneous COPunit of these systems varied from 0.1 to 1.4 during typical summer week operation. The COP was low because the gas engines for the heat pumps were being used for loads that were much lower than design capacity which resulted in much lower efficiencies than expected. The performance of equivalent electric heat pump was simulated from a building energy model developed to mimic the measured building loads. An economic comparison of GEHPs and conventional electrical heat pumps was done based on the measured and simulated results. The average performance of the GEHP units was estimated to lie between those of EER-9.2 and EER-11.8 systems. The performance of GEHP systems suffers due to lower efficiency at

  10. A Statistical Analysis of the Economic Drivers of Battery Energy Storage in Commercial Buildings: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Long, Matthew; Simpkins, Travis; Cutler, Dylan; Anderson, Katie

    2016-11-01

    There is significant interest in using battery energy storage systems (BESS) to reduce peak demand charges, and therefore the life cycle cost of electricity, in commercial buildings. This paper explores the drivers of economic viability of BESS in commercial buildings through statistical analysis. A sample population of buildings was generated, a techno-economic optimization model was used to size and dispatch the BESS, and the resulting optimal BESS sizes were analyzed for relevant predictor variables. Explanatory regression analyses were used to demonstrate that peak demand charges are the most significant predictor of an economically viable battery, and that the shape of the load profile is the most significant predictor of the size of the battery.

  11. A Statistical Analysis of the Economic Drivers of Battery Energy Storage in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Long, Matthew; Simpkins, Travis; Cutler, Dylan; Anderson, Kate

    2016-11-21

    There is significant interest in using battery energy storage systems (BESS) to reduce peak demand charges, and therefore the life cycle cost of electricity, in commercial buildings. This paper explores the drivers of economic viability of BESS in commercial buildings through statistical analysis. A sample population of buildings was generated, a techno-economic optimization model was used to size and dispatch the BESS, and the resulting optimal BESS sizes were analyzed for relevant predictor variables. Explanatory regression analyses were used to demonstrate that peak demand charges are the most significant predictor of an economically viable battery, and that the shape of the load profile is the most significant predictor of the size of the battery.

  12. Machine to machine (M2M) technology in demand responsive commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Watson, David S.; Piette, Mary Ann; Sezgen, Osman; Motegi, Naoya; ten Hope, Laurie

    2004-08-01

    Machine to Machine (M2M) is a term used to describe the technologies that enable computers, embedded processors, smart sensors, actuators and mobile devices to communicate with one another, take measurements and make decisions--often without human intervention. M2M technology was applied to five commercial buildings in a test. The goal was to reduce electric demand when a remote price signal rose above a predetermine price. In this system, a variable price signal was generated from a single source on the Internet and distributed using the meta-language, XML (Extensible Markup Language). Each of five commercial building sites monitored the common price signal and automatically shed site-specific electric loads when the price increased above predetermined thresholds. Other than price signal scheduling, which was set up in advance by the project researchers, the system was designed to operate without human intervention during the two-week test period. Although the buildings responded to the same price signal, the communication infrastructures used at each building were substantially different. This study provides an overview of the technologies used at each building site, the price generator/server, and each link in between. Network architecture, security, data visualization and site-specific system features are characterized. The results of the test are discussed, including: functionality at each site, measurement and verification techniques, and feedback from energy managers and building operators. Lessons learned from the test and potential implications for widespread rollout are provided.

  13. Results and Lessons Learned From the DOE Commercial Building Partnerships: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, A.; Deru, M.; Langner, R.; Stark, G.; Doebber, I.; Scheib, J.; Sheppy, M.; Bonnema, E.; Pless, S.; Livingood, B.; Torcellini, P.

    2014-09-01

    Over the course of 5 years, NREL worked with commercial building owners and their design teams in the DOE Commercial Building Partnerships (CBP) to cut energy consumption by 50% in new construction (versus code) and by 30% in existing building pilot projects (versus code or pre-retrofit operational energy use depending on the preference of the Partner) using strategies that could be replicated across their building portfolios. A number of different building types were addressed, including supermarket, retail merchandise, combination big box (general merchandise and food sales), high rise office space, and warehouse. The projects began in pre-design and included a year of measurement data to evaluate performance against design expectations. Focused attention was required throughout the entire process to achieve a design with the potential to hit the energy performance target and to operate the resulting building to reach this potential. This paper will report quantitative results and cover both the technical and the human sides of CBP, including the elements that were required to succeed and where stumbling blocks were encountered. It will also address the impact of energy performance goals and intensive energy modeling on the design process innovations and best practices.

  14. iHand: an interactive bare-hand-based augmented reality interface on commercial mobile phones

    Science.gov (United States)

    Choi, Junyeong; Park, Jungsik; Park, Hanhoon; Park, Jong-Il

    2013-02-01

    The performance of mobile phones has rapidly improved, and they are emerging as a powerful platform. In many vision-based applications, human hands play a key role in natural interaction. However, relatively little attention has been paid to the interaction between human hands and the mobile phone. Thus, we propose a vision- and hand gesture-based interface in which the user holds a mobile phone in one hand but sees the other hand's palm through a built-in camera. The virtual contents are faithfully rendered on the user's palm through palm pose estimation, and reaction with hand and finger movements is achieved that is recognized by hand shape recognition. Since the proposed interface is based on hand gestures familiar to humans and does not require any additional sensors or markers, the user can freely interact with virtual contents anytime and anywhere without any training. We demonstrate that the proposed interface works at over 15 fps on a commercial mobile phone with a 1.2-GHz dual core processor and 1 GB RAM.

  15. DEEP: A Database of Energy Efficiency Performance to Accelerate Energy Retrofitting of Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hoon Lee, Sang; Hong, Tianzhen; Sawaya, Geof; Chen, Yixing; Piette, Mary Ann

    2015-05-01

    The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions and 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct

  16. Comparison of Standard 90.1-2007 and the 2009 IECC with Respect to Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Conover, David R.; Bartlett, Rosemarie; Halverson, Mark A.

    2009-12-11

    The U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP) has been asked by some states and energy code stakeholders to address the comparability of the 2009 International Energy Conservation Code® (IECC) as applied to commercial buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 (hereinafter referred to as Standard 90.1-07). An assessment of comparability will help states respond to and implement conditions specified in the State Energy Program (SEP) Formula Grants American Recovery and Reinvestment Act Funding Opportunity, Number DE-FOA-0000052, and eliminate the need for the states individually or collectively to perform comparative studies of the 2009 IECC and Standard 90.1-07. The funding opportunity announcement contains the following conditions: (2) The State, or the applicable units of local government that have authority to adopt building codes, will implement the following: (A) A residential building energy code (or codes) that meets or exceeds the most recent International Energy Conservation Code, or achieves equivalent or greater energy savings. (B) A commercial building energy code (or codes) throughout the State that meets or exceeds the ANSI/ASHRAE/IESNA Standard 90.1-2007, or achieves equivalent or greater energy savings . (C) A plan to achieve 90 percent compliance with the above energy codes within eight years. This plan will include active training and enforcement programs and annual measurement of the rate of compliance. With respect to item (B) above, many more states, regardless of the edition date, directly adopt the IECC than Standard 90.1-07. This is predominately because the IECC is a model code and part of a coordinated set of model building codes that state and local government have historically adopted to regulate building design and construction. This report compares the 2009 IECC to Standard 90.1-07 with the intent of helping states address whether the adoption and application of the 2009 IECC for commercial

  17. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Zhuge, Jing Wei [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

    2015-09-01

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildings constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

  18. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhuge, Jing Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-06-01

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildings constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

  19. Earthdata User Interface Patterns: Building Usable Web Interfaces Through a Shared UI Pattern Library

    Science.gov (United States)

    Siarto, J.

    2014-12-01

    As more Earth science software tools and services move to the web--the design and usability of those tools become ever more important. A good user interface is becoming expected and users are becoming increasingly intolerant of websites and web applications that work against them. The Earthdata UI Pattern Library attempts to give these scientists and developers the design tools they need to make usable, compelling user interfaces without the associated overhead of using a full design team. Patterns are tested and functional user interface elements targeted specifically at the Earth science community and will include web layouts, buttons, tables, typography, iconography, mapping and visualization/graphing widgets. These UI elements have emerged as the result of extensive user testing, research and software development within the NASA Earthdata team over the past year.

  20. Monitoring the Energy-Use Effects of Cool Roofs on California Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Konopaki, Steve; Rainer, Leo

    2004-07-01

    Solar-reflective roofs stay cooler in the sun than solar-absorptive roofs. Such ''cool'' roofs achieve lower surface temperatures that reduce heat conduction into the building and the building's cooling load. The California Energy Commission has funded research in which Lawrence Berkeley National Laboratory (LBNL) has measured the electricity use and peak demand in commercial buildings to document savings from implementing the Commission's Cool Roofs program. The study seeks to determine the savings achieved by cool roofs by monitoring the energy use of a carefully selected assortment of buildings participating in the Cool Roofs program. Measurements were needed because the peak savings resulting from the application of cool roofs on different types of buildings in the diverse California climate zones have not been well characterized to date. Only a few occupancy categories (e.g., office and retail buildings) have been monitored before this, and those were done under a limited number of climatic conditions. To help rectify this situation, LBNL was tasked to select the buildings to be monitored, measure roof performance before and after replacing a hot roof by a cool roof, and document both energy and peak demand savings resulting from installation of cool roofs. We monitored the effects of cool roofs on energy use and environmental parameters in six California buildings at three different sites: a retail store in Sacramento; an elementary school in San Marcos (near San Diego); and a 4-building cold storage facility in Reedley (near Fresno). The latter included a cold storage building, a conditioning and fruit-palletizing area, a conditioned packing area, and two unconditioned packing areas (counted as one building).

  1. Water movement in building walls: interfaces influence on the moisture flux

    Science.gov (United States)

    Delgado, J. M. P. Q.; de Freitas, V. P.; Guimarães, A. S.

    2016-11-01

    Most building elements are a composite of different material layers; however the majority of the works presented in literature were developed for multi-layered elements with perfect contact interface, without resistance. Experimental results presented in literature showed that a considerable hydraulic resistance could be created by the imperfect contact between two porous building materials. Moisture transport in multi-layered building elements can deviate from the moisture transport found for the combination of the single material elements, so the assumption of perfect hydraulic contact could lead to significant errors in predicting the moisture transport. This work presents an experimental campaign and a critical analysis of water absorption in samples of two different building materials (clay brick and autoclaved aerated concrete) with and without joints at different positions (heights) and different contact configurations (natural contact and air space between layers). The results show that when the moisture reaches the interface there is a slowing of the wetting process due to the interfaces hygric resistance. The interfaces hygric resistance, in the AAC samples, is only observed for the joint located from a distance of 2 cm of the wetting plane. The penetration coefficient of the two building materials analysed is very different. Finally, the evolution of the distribution of liquid in the porous medium was analysed in terms of the Boltzmann transform method and anomalous diffusion equation.

  2. Field Experience with and Potential for Multi-time Scale Grid Transactions from Responsive Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Kiliccote, Sila; Ghatikar, Girish

    2014-08-01

    The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis is based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.

  3. Energy benchmarking of commercial buildings: a low-cost pathway toward urban sustainability

    Science.gov (United States)

    Cox, Matt; Brown, Marilyn A.; Sun, Xiaojing

    2013-09-01

    US cities are beginning to experiment with a regulatory approach to address information failures in the real estate market by mandating the energy benchmarking of commercial buildings. Understanding how a commercial building uses energy has many benefits; for example, it helps building owners and tenants identify poor-performing buildings and subsystems and it enables high-performing buildings to achieve greater occupancy rates, rents, and property values. This paper estimates the possible impacts of a national energy benchmarking mandate through analysis chiefly utilizing the Georgia Tech version of the National Energy Modeling System (GT-NEMS). Correcting input discount rates results in a 4.0% reduction in projected energy consumption for seven major classes of equipment relative to the reference case forecast in 2020, rising to 8.7% in 2035. Thus, the official US energy forecasts appear to overestimate future energy consumption by underestimating investments in energy-efficient equipment. Further discount rate reductions spurred by benchmarking policies yield another 1.3-1.4% in energy savings in 2020, increasing to 2.2-2.4% in 2035. Benchmarking would increase the purchase of energy-efficient equipment, reducing energy bills, CO2 emissions, and conventional air pollution. Achieving comparable CO2 savings would require more than tripling existing US solar capacity. Our analysis suggests that nearly 90% of the energy saved by a national benchmarking policy would benefit metropolitan areas, and the policy’s benefits would outweigh its costs, both to the private sector and society broadly.

  4. Modeling carbon dioxide emissions reductions for three commercial reference buildings in Salt Lake City

    Science.gov (United States)

    Lucich, Stephen M.

    In the United States, the buildings sector is responsible for approximately 40% of the national carbon dioxide (CO2) emissions. CO2 is created during the generation of heat and electricity, and has been linked to climate change, acid rain, a variety of health threats, surface water depletion, and the destruction of natural habitats. Building energy modeling is a powerful educational tool that building owners, architects, engineers, city planners, and policy makers can use to make informed decisions. The aim of this thesis is to simulate the reduction in CO2 emissions that may be achieved for three commercial buildings located in Salt Lake City, UT. The following two questions were used to guide this process: 1. How much can a building's annual CO2 emissions be reduced through a specific energy efficiency upgrade or policy? 2. How much can a building's annual CO2 emissions be reduced through the addition of a photovoltaic (PV) array? How large should the array be? Building energy simulations were performed with the Department of Energy's EnergyPlus software, commercial reference building models, and TMY3 weather data. The chosen models were a medium office building, a primary school, and a supermarket. Baseline energy consumption data were simulated for each model in order to identify changes that would have a meaningful impact. Modifications to the buildings construction and operation were considered before a PV array was incorporated. These modifications include (1) an improved building envelope, (2) reduced lighting intensity, and (3) modified HVAC temperature set points. The PV array sizing was optimized using a demand matching approach based on the method of least squares. The arrays tilt angle was optimized using the golden section search algorithm. Combined, energy efficiency upgrades and the PV array reduced building CO2 emissions by 58.6, 54.0, and 52.2% for the medium office, primary school, and supermarket, respectively. However, for these models, it was

  5. Energy management in residential and small commercial buildings. Annual report, fiscal year 1976

    Energy Technology Data Exchange (ETDEWEB)

    Batey, J.; Gazerro, V.; Salzano, F.J.; Berlad, A.L.

    1976-07-01

    The goal of the present program is to develop the technical basis for efficient energy use in space heating of residential and small commercial buildings. Efficiency measurements performed on conventional residential oil-fired hot water heating equipment, including both steady state and cyclic (part load) efficiency determinations are described. A list of preliminary recommendations for retrofit actions to improve efficiency is provided. A summary of work carried out in the areas of thermal storage media, fenestration, and building thermal dynamics is also presented.

  6. Analysis of Potential Benefits and Costs of Updating the Commercial Building Energy Code in Iowa

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Belzer, David B.; Richman, Eric E.; Winiarski, David W.

    2002-09-07

    The state of Iowa is considering adpoting ASHRAE 90.1-1999 as its commercial building energy code. In an effort to evaluate whether or not this is an appropraite code for the state, the potential benefits and costs of adopting this standard are considered. Both qualitative and quantitative benefits are assessed. The energy simulation and economic results suggest that adopting ASHRAE 90.1-1999 would provide postitive net benefits to the state relative to the building and design requirements currently in place.

  7. Modeling and Analysis of Commercial Building Electrical Loads for Demand Side Management

    Science.gov (United States)

    Berardino, Jonathan

    In recent years there has been a push in the electric power industry for more customer involvement in the electricity markets. Traditionally the end user has played a passive role in the planning and operation of the power grid. However, many energy markets have begun opening up opportunities to consumers who wish to commit a certain amount of their electrical load under various demand side management programs. The potential benefits of more demand participation include reduced operating costs and new revenue opportunities for the consumer, as well as more reliable and secure operations for the utilities. The management of these load resources creates challenges and opportunities to the end user that were not present in previous market structures. This work examines the behavior of commercial-type building electrical loads and their capacity for supporting demand side management actions. This work is motivated by the need for accurate and dynamic tools to aid in the advancement of demand side operations. A dynamic load model is proposed for capturing the response of controllable building loads. Building-specific load forecasting techniques are developed, with particular focus paid to the integration of building management system (BMS) information. These approaches are tested using Drexel University building data. The application of building-specific load forecasts and dynamic load modeling to the optimal scheduling of multi-building systems in the energy market is proposed. Sources of potential load uncertainty are introduced in the proposed energy management problem formulation in order to investigate the impact on the resulting load schedule.

  8. Development of a methodology for defining whole-building energy design targets for commercial buildings: Phase 2, Development Concept Stage Report

    Energy Technology Data Exchange (ETDEWEB)

    Deringer, J.J. (American Inst. of Architects, Washington, DC (USA)); Hall, J.D. (Deringer Group, Riva, MD (USA)); Jones, J.W. (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., New York, NY (USA)); McKay, H.N. (Illuminating Engineering Society of North America, New York, NY (USA)); Alley, P.K. (Pacific Northwest Lab., Richland, WA (USA))

    1990-09-01

    The primary focus of the Whole-Building Energy Design Targets project is to develop a flexible methodology for setting target guidelines with which to assess energy efficiency in commercial building design. The proposed methodology has several innovative features. In this report, the authors document their work to define the software development concepts upon which the overall Targets methodology will be based. Three task reports are included here. Development of the user interface--that critical connection through which the human end-user (architect, engineer, planner, owner) will apply the methodology--is described in Section 2. In Section 3, the use of the software engineering process in Targets model development efforts is described. Section 4 provides details on the data and system integration task, in which interactions between and among all the major components, termed modules, of the Targets model were examined to determine how to put them together to create a methodology that is effective and easy to use. 4 refs., 26 figs.

  9. Light Environment Analysis and Design Strategies of Large Commercial Buildings-A Case Study in Harbin

    Institute of Scientific and Technical Information of China (English)

    Hong Jin; XinXin Li

    2014-01-01

    This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information, subjective and objective fieldwork and online survey for three typical commercial building forms ( centralized form, covered mall shopping center, lifestyle center ) . Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality, subjective assessment among daylight and artificial illumination, effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis, the improving strategies for light environment are proposed in terms of making use of daylight, artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.

  10. Assessing Potential Energy Cost Savings from Increased Energy Code Compliance in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energy code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.

  11. Development and Evaluation of Algorithms to Improve Small- and Medium-Size Commercial Building Operations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woohyun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lutes, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Underhill, Ronald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    Small- and medium-sized (<100,000 sf) commercial buildings (SMBs) represent over 95% of the U.S. commercial building stock and consume over 60% of total site energy consumption. Many of these buildings use rudimentary controls that are mostly manual, with limited scheduling capability, no monitoring or failure management. Therefore, many of these buildings are operated inefficiently and consume excess energy. SMBs typically utilize packaged rooftop units (RTUs) that are controlled by an individual thermostat. There is increased urgency to improve the operating efficiency of existing commercial building stock in the U.S. for many reasons, chief among them is to mitigate the climate change impacts. Studies have shown that managing set points and schedules of the RTUs will result in up to 20% energy and cost savings. Another problem associated with RTUs is short-cycling, where an RTU goes through ON and OFF cycles too frequently. Excessive cycling can lead to excessive wear and lead to premature failure of the compressor or its components. The short cycling can result in a significantly decreased average efficiency (up to 10%), even if there are no physical failures in the equipment. Also, SMBs use a time-of-day scheduling is to start the RTUs before the building will be occupied and shut it off when unoccupied. Ensuring correct use of the zone set points and eliminating frequent cycling of RTUs thereby leading to persistent building operations can significantly increase the operational efficiency of the SMBs. A growing trend is to use low-cost control infrastructure that can enable scalable and cost-effective intelligent building operations. The work reported in this report describes three algorithms for detecting the zone set point temperature, RTU cycling rate and occupancy schedule detection that can be deployed on the low-cost infrastructure. These algorithms only require the zone temperature data for detection. The algorithms have been tested and validated using

  12. Increased use of solar energy in commercial buildings by integrating energy storage.

    OpenAIRE

    Nilsson, Nina

    2016-01-01

    From a comparison of available thermal energy storage (TES) technologies it can be concluded that the most mature and suitable storage methods for modern commercial buildings in Sweden are storage tanks, either for heat or cold energy, and underground storage solutions such as borehole thermal energy storage (BTES), aquifer storage and energy piles. In this study an integrated solar energy storage system for heating purpose has been designed with BTES, hot water storage tank(s) and solar ther...

  13. "Watts per person" paradigm to design net zero energy buildings: Examining technology interventions and integrating occupant feedback to reduce plug loads in a commercial building

    Science.gov (United States)

    Yagi Kim, Mika

    As building envelopes have improved due to more restrictive energy codes, internal loads have increased largely due to the proliferation of computers, electronics, appliances, imaging and audio visual equipment that continues to grow in commercial buildings. As the dependency on the internet for information and data transfer increases, the electricity demand will pose a challenge to design and operate Net Zero Energy Buildings (NZEBs). Plug Loads (PLs) as a proportion of the building load has become the largest non-regulated building energy load and represents the third highest electricity end-use in California's commercial office buildings, accounting for 23% of the total building electricity consumption (Ecova 2011,2). In the Annual Energy Outlook 2008 (AEO2008), prepared by the Energy Information Administration (EIA) that presents long-term projections of energy supply and demand through 2030 states that office equipment and personal computers are the "fastest growing electrical end uses" in the commercial sector. This thesis entitled "Watts Per Person" Paradigm to Design Net Zero Energy Buildings, measures the implementation of advanced controls and behavioral interventions to study the reduction of PL energy use in the commercial sector. By integrating real world data extracted from an energy efficient commercial building of its energy use, the results produce a new methodology on estimating PL energy use by calculating based on "Watts Per Person" and analyzes computational simulation methods to design NZEBs.

  14. Space Heaters, Computers, Cell Phone Chargers: How Plugged In AreCommercial Buildings?

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Marla; Webber, Carrie; Brown, Richard; Busch, John; Pinckard, Margaret; Roberson, Judy

    2007-02-28

    Evidenceof electric plug loads in commercial buildings isvisible everyday: space heaters, portable fans, and the IT technician'stwo monitors connected to one PC. The Energy Information Administrationestimates that office and miscellaneous equipment together will consume2.18 quads in 2006, nearly 50 percent of U.S. commercial electricity use.Although the importance of commercial plug loads is documented, its verynature (diverse product types, products not installed when buildinginitially constructed, and products often hidden in closets) makes itdifficult to accurately count and categorize the end use.We auditedsixteen buildings in three cities (San Francisco, Atlanta, Pittsburgh)including office, medical and education building types. We inventoriedthe number and types of office and miscellaneous electric equipment aswell as estimated total energy consumption due to these product types. Intotal, we audited approximately 4,000 units of office equipment and 6,000units of miscellaneous equipment and covered a diverse range of productsranging from electric pencil sharpeners with a unit energy consumption(UEC) of 1 kWh/yr to a kiln with a UEC of 7,000 kWh/yr. Our paperpresents a summary of the density and type of plug load equipment foundas well as the estimated total energy consumption of the equipment.Additionally, we present equipment trends observed and provide insightsto how policy makers can target energy efficiency for this growing enduse.

  15. Review of California and National Methods for Energy PerformanceBenchmarking of Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Matson, Nance E.; Piette, Mary Ann

    2005-09-05

    This benchmarking review has been developed to support benchmarking planning and tool development under discussion by the California Energy Commission (CEC), Lawrence Berkeley National Laboratory (LBNL) and others in response to the Governor's Executive Order S-20-04 (2004). The Executive Order sets a goal of benchmarking and improving the energy efficiency of California's existing commercial building stock. The Executive Order requires the CEC to propose ''a simple building efficiency benchmarking system for all commercial buildings in the state''. This report summarizes and compares two currently available commercial building energy-benchmarking tools. One tool is the U.S. Environmental Protection Agency's Energy Star National Energy Performance Rating System, which is a national regression-based benchmarking model (referred to in this report as Energy Star). The second is Lawrence Berkeley National Laboratory's Cal-Arch, which is a California-based distributional model (referred to as Cal-Arch). Prior to the time Cal-Arch was developed in 2002, there were several other benchmarking tools available to California consumers but none that were based solely on California data. The Energy Star and Cal-Arch benchmarking tools both provide California with unique and useful methods to benchmark the energy performance of California's buildings. Rather than determine which model is ''better'', the purpose of this report is to understand and compare the underlying data, information systems, assumptions, and outcomes of each model.

  16. Automated Demand Response Technology Demonstration Project for Small and Medium Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Page, Janie; Kiliccote, Sila; Dudley, Junqiao Han; Piette, Mary Ann; Chiu, Albert K.; Kellow, Bashar; Koch, Ed; Lipkin, Paul

    2011-07-01

    Small and medium commercial customers in California make up about 20-25% of electric peak load in California. With the roll out of smart meters to this customer group, which enable granular measurement of electricity consumption, the investor-owned utilities will offer dynamic prices as default tariffs by the end of 2011. Pacific Gas and Electric Company, which successfully deployed Automated Demand Response (AutoDR) Programs to its large commercial and industrial customers, started investigating the same infrastructures application to the small and medium commercial customers. This project aims to identify available technologies suitable for automating demand response for small-medium commercial buildings; to validate the extent to which that technology does what it claims to be able to do; and determine the extent to which customers find the technology useful for DR purpose. Ten sites, enabled by eight vendors, participated in at least four test AutoDR events per site in the summer of 2010. The results showed that while existing technology can reliably receive OpenADR signals and translate them into pre-programmed response strategies, it is likely that better levels of load sheds could be obtained than what is reported here if better understanding of the building systems were developed and the DR response strategies had been carefully designed and optimized for each site.

  17. Demand Shifting with Thermal Mass in Light and Heavy Mass Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Peng; Zagreus, Leah

    2009-05-01

    The potential for utilizing building thermal mass for load shifting and peak demand reduction has been demonstrated in a number of simulation, laboratory, and field studies. This project studied the potential of pre-cooling and demand limiting in a heavy mass and a light mass building in the Bay Area of California. The conclusion of the work to date is that pre-cooling has the potential to improve the demand responsiveness of commercial buildings while maintaining acceptable comfort conditions. Results indicate that pre-cooling increases the depth (kW) and duration (kWh) of the shed capacity of a given building, all other factors being equal. Due to the time necessary for pre-cooling, it is only applicable to day-ahead demand response programs. Pre-cooling can be very effective if the building mass is relatively heavy. The effectiveness of night pre-cooling under hot weather conditions has not been tested. Further work is required to quantify and demonstrate the effectiveness of pre-cooling in different climates. Research is also needed to develop screening tools that can be used to select suitable buildings and customers, identify the most appropriate pre-cooling strategies, and estimate the benefits to the customer and the utility.

  18. Economic analysis of solar assisted absorption chiller for a commercial building

    Science.gov (United States)

    Antonyraj, Gnananesan

    Dwindling fossil fuels coupled with changes in global climate intensified the drive to make use of renewable energy resources that have negligible impact on the environment. In this attempt, the industrial community produced various devices and systems to make use of solar energy for heating and cooling of building space as well as generate electric power. The most common components employed for collection of solar energy are the flat plate and evacuated tube collectors that produce hot water that can be employed for heating the building space. In order to cool the building, the absorption chiller is commonly employed that requires hot water at high temperatures for its operation. This thesis deals with economic analysis of solar collector and absorption cooling system to meet the building loads of a commercial building located in Chattanooga, Tennessee. Computer simulations are employed to predict the hourly building loads and performance of the flat plate and evacuated tube solar collectors using the hourly weather data. The key variables affecting the economic evaluation of such system are identified and the influence of these parameters is presented. The results of this investigation show that the flat plate solar collectors yield lower payback period compared to the evacuated tube collectors and economic incentives offered by the local and federal agencies play a major role in lowering the payback period.

  19. CO2 heat pumps for commercial building applications with simultaneous heating and cooling demand

    Science.gov (United States)

    Dharkar, Supriya

    Many commercial buildings, including data centers, hotels and hospitals, have a simultaneous heating and cooling demand depending on the season, occupation and auxiliary equipment. A data center on the Purdue University, West Lafayette campus is used as a case study. The electrical equipment in data centers produce heat, which must be removed to prevent the equipment temperature from rising to a certain level. With proper integration, this heat has the potential to be used as a cost-effective energy source for heating the building in which the data center resides or the near-by buildings. The proposed heat pump system utilizes carbon dioxide with global warming potential of 1, as the refrigerant. System simulations are carried out to determine the feasibility of the system for a 12-month period. In addition, energy, environmental and economic analyses are carried out to show the benefits of this alternative technology when compared to the conventional system currently installed in the facility. Primary energy savings of ~28% to ~61%, a payback period of 3 to 4.5 years and a decrease in the environmental impact value by ~36% makes this system an attractive option. The results are then extended to other commercial buildings.

  20. Improving HVAC operational efficiency in small-and medium-size commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woohyun; Katipamula, Srinivas; Lutes, Robert

    2017-08-01

    Small- and medium-size (<100,000 sf) commercial buildings (SMBs) represent over 95% of the U.S. commercial building stock and consume over 60% of total site energy consumption. Many of these buildings use rudimentary controls that are mostly manual, with limited scheduling capability, no monitoring, or failure management. Therefore, many of these buildings are operated inefficiently and consume excess energy. SMBs typically use packaged rooftop units (RTUs) that are controlled by an individual thermostat. There is increased urgency to improve the operating efficiency of existing commercial building stock in the United States for many reasons, chief among them being to mitigate the climate change impacts. Studies have shown that managing set points and schedules of the RTUs will result in up to 20% energy and cost savings. Another problem associated with RTUs is short cycling, when an RTU goes through ON and OFF cycles too frequently. Excessive cycling can lead to excessive wear and to premature failure of the compressor or its components. Also, short cycling can result in a significantly decreased average efficiency (up to 10%), even if there are no physical failures in the equipment. Ensuring correct use of the zone set points and eliminating frequent cycling of RTUs thereby leading to persistent building operations can significantly increase the operational efficiency of the SMBs. A growing trend is to use low-cost control infrastructure that can enable scalable and cost-effective intelligent building operations. The work reported in this paper describes two algorithms for detecting the zone set point temperature and RTU cycling rate that can be deployed on the low-cost infrastructure. These algorithms only require the zone temperature data for detection. The algorithms have been tested and validated using field data from a number of RTUs from six buildings in different climate locations. Overall, the algorithms were successful in detecting the set points and ON

  1. Measurement Issues for Energy Efficient Commercial Buildings: Productivity and Performance Uncertainties

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.W.

    2002-05-16

    In previous reports, we have identified two potentially important issues, solutions to which would increase the attractiveness of DOE-developed technologies in commercial buildings energy systems. One issue concerns the fact that in addition to saving energy, many new technologies offer non-energy benefits that contribute to building productivity (firm profitability). The second issue is that new technologies are typically unproven in the eyes of decision makers and must bear risk premiums that offset cost advantages resulting from laboratory calculations. Even though a compelling case can be made for the importance of these issues, for building decision makers to incorporate them in business decisions and for DOE to use them in R&D program planning there must be robust empirical evidence of their existence and size. This paper investigates how such measurements could be made and offers recommendations as to preferred options. There is currently little systematic information on either of these concepts in the literature. Of the two there is somewhat more information on non-energy benefits, but little as regards office buildings. Office building productivity impacts can be observed casually, but must be estimated statistically, because buildings have many interacting attributes and observations based on direct behavior can easily confuse the process of attribution. For example, absenteeism can be easily observed. However, absenteeism may be down because a more healthy space conditioning system was put into place, because the weather was milder, or because firm policy regarding sick days had changed. There is also a general dearth of appropriate information for purposes of estimation. To overcome these difficulties, we propose developing a new data base and applying the technique of hedonic price analysis. This technique has been used extensively in the analysis of residential dwellings. There is also a literature on its application to commercial and industrial

  2. The Power of Flexibility: Autonomous Agents That Conserve Energy in Commercial Buildings

    Science.gov (United States)

    Kwak, Jun-young

    Agent-based systems for energy conservation are now a growing area of research in multiagent systems, with applications ranging from energy management and control on the smart grid, to energy conservation in residential buildings, to energy generation and dynamic negotiations in distributed rural communities. Contributing to this area, my thesis presents new agent-based models and algorithms aiming to conserve energy in commercial buildings. More specifically, my thesis provides three sets of algorithmic contributions. First, I provide online predictive scheduling algorithms to handle massive numbers of meeting/event scheduling requests considering flexibility , which is a novel concept for capturing generic user constraints while optimizing the desired objective. Second, I present a novel BM-MDP ( Bounded-parameter Multi-objective Markov Decision Problem) model and robust algorithms for multi-objective optimization under uncertainty both at the planning and execution time. The BM-MDP model and its robust algorithms are useful in (re)scheduling events to achieve energy efficiency in the presence of uncertainty over user's preferences. Third, when multiple users contribute to energy savings, fair division of credit for such savings to incentivize users for their energy saving activities arises as an important question. I appeal to cooperative game theory and specifically to the concept of Shapley value for this fair division. Unfortunately, scaling up this Shapley value computation is a major hindrance in practice. Therefore, I present novel approximation algorithms to efficiently compute the Shapley value based on sampling and partitions and to speed up the characteristic function computation. These new models have not only advanced the state of the art in multiagent algorithms, but have actually been successfully integrated within agents dedicated to energy efficiency: SAVES, TESLA and THINC. SAVES focuses on the day-to-day energy consumption of individuals and

  3. Evaluating the energy performance of the first generation of LEED-certified commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, Rick; Opitz, Mike; Hicks, Tom; Von Neida, Bill; Herrera, Shawn

    2006-05-01

    Over three hundred buildings have been certified under the Leadership in Energy and Environmental Design (LEED) rating system for sustainable commercial buildings as of January 2006. This paper explores the modeled and actual energy performance of a sample of 21 of these buildings that certified under LEED between December 2001 and August 2005, including how extensively the design teams pursued LEED energy-efficiency credits, the modeled design and baseline energy performance, and the actual energy use during the first few years of operation. We collected utility billing data from 2003-2005 and compared the billed energy consumption with the modeled energy use. We also calculated Energy Star ratings for the buildings and compared them to peer groups where possible. The mean savings modeled for the sample was 27% compared to their modeled baseline values. For the group of 18 buildings for which we have both modeled and billed energy use, the mean value for actual consumption was 1% lower than modeled energy use, with a wide variation around the mean. The mean Energy Star score was 71 out of a total of 100 points, higher than the average score of 50 but slightly below the Energy Star award threshold of 75 points. The paper discusses the limitations inherent to this type of analysis, such as the small sample size of disparate buildings, the uncertainties in actual floor area, and the discrepancies between metered sections of the buildings. Despite these limitations, the value of the work is that it presents an early view of the actual energy performance for a set of 21 LEED-certified buildings.

  4. Pilot project for a commercial buildings Energy Analysis and Diagnostic Center (EADC) program. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Capehart, B.L.

    1996-02-01

    Commercial energy use costs businesses around $70 billion annually. Many of these businesses are small and medium sized organizations that do not have the resources to help themselves, or to pay for professional engineering services to help reduce their energy costs and improve their economic competitiveness. Energy cost reduction actions with payback times of around two years could save the commercial sector 15--20%, or $10--$15 billion per year. This project was initially intended to evaluate the feasibility of performing commercial energy audits as an adjunct to the industrial audit program run by the US Department of Energy Industrial Office. This program is housed in 30 universities throughout the United States. Formerly known as Energy Analysis and Diagnostic Centers (EADC`s), the university programs are now called Industrial Assessment Centers (IAC`s) to reflect their expansion from energy use analyses to include waste and productivity analyses. The success of the EADC/IAC program in helping the manufacturing sector provides an excellent model for a similar program in the commercial buildings sector. This project has investigated using the EADC/IAC approach to performing energy audits for the commercial sector, and has determined that such an approach is feasible and cost effective.

  5. Start point to savings - Better load demand analysis in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Abaravicius, Juozas; Pyrko, Jurek [Lund Univ., Dept of Energy Sciences (Sweden)

    2007-07-01

    Existing installations and energy systems in most commercial buildings could be used in a more efficient way to provide savings - both in terms of energy and load demand. The key for effective operation is a thorough and detailed analysis of energy use patterns that creates essential baseline for energy savings and the development of demand response (DR) strategies. The knowledge of energy demand variations is still very limited and the use of methods to analyse the load demand is rare. Many utilities have recently installed interval (hourly) metering even for smaller commercial users and households. This is a big step forward; however, experience shows that the data is being used only to a limited extent, mostly for billing purposes only. This paper reports about a study conducted with the objective of developing a detailed load demand analysis for commercial buildings. The study results should provide essential information for the formation and evaluation of future DR and energy efficiency strategies. This study was performed in collaboration with IKEA and E.ON and contributes to an ongoing IKEA energy efficiency programme. Two sample department stores in Sweden were selected and analysed within this project. The demand data analysis covers almost 3 years period, 2004-2006.This study contributes to new knowledge of energy use patterns (load demand) in commercial buildings. It proposes solutions of load-related problems, evaluates energy and load savings potential, identifies and analyses the needs, motives and barriers for participation in DR programmes. The study provides recommendations for ongoing and future efficiency and DR strategies and discusses the potential economic benefits from the DR measures.

  6. Web-based energy information systems for energy management and demand response in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Motegi, Naoya; Piette, Mary Ann; Kinney, Satkartar; Herter, Karen

    2003-04-18

    Energy Information Systems (EIS) for buildings are becoming widespread in the U.S., with more companies offering EIS products every year. As a result, customers are often overwhelmed by the quickly expanding portfolio of EIS feature and application options, which have not been clearly identified for consumers. The object of this report is to provide a technical overview of currently available EIS products. In particular, this report focuses on web-based EIS products for large commercial buildings, which allow data access and control capabilities over the Internet. EIS products combine software, data acquisition hardware, and communication systems to collect, analyze and display building information to aid commercial building energy managers, facility managers, financial managers and electric utilities in reducing energy use and costs in buildings. Data types commonly processed by EIS include energy consumption data; building characteristics; building system data, such as heating, ventilation, and air-conditioning (HVAC) and lighting data; weather data; energy price signals; and energy demand-response event information. This project involved an extensive review of research and trade literature to understand the motivation for EIS technology development. This study also gathered information on currently commercialized EIS. This review is not an exhaustive analysis of all EIS products; rather, it is a technical framework and review of current products on the market. This report summarizes key features available in today's EIS, along with a categorization framework to understand the relationship between EIS, Energy Management and Control Systems (EMCSs), and similar technologies. Four EIS types are described: Basic Energy Information Systems (Basic-EIS); Demand Response Systems (DRS); Enterprise Energy Management (EEM); and Web-based Energy Management and Control Systems (Web-EMCS). Within the context of these four categories, the following characteristics of EIS

  7. Improving Occupant Wellness in Commercial Office Buildings through Energy Conservation Retrofits

    Directory of Open Access Journals (Sweden)

    J. J. McArthur

    2015-10-01

    Full Text Available There is increasing literature demonstrating the link between building indoor environmental quality, and occupant health and productivity, driving the corporate real estate industry to investigate how to integrate wellness features in both new and existing building stock. Meanwhile, new voluntary standards to promote occupant health are becoming adopted alongside sustainability standards. As commercial building owners and tenants seek to improve occupant conditions and incorporate wellness, apparently conflicting priorities must be balanced, particularly improving indoor environmental conditions has the potential to increase energy. This paper presents a framework to consider retrofits holistically and considering the benefit of improved conditions both qualitatively and quantitatively. Where poor conditions exist, published literature demonstrates a lost productivity cost that exceeds typical building energy costs, and this is quantified in the financial analysis presented. Energy retrofits provide a unique opportunity to integrate wellness-enabling features because the energy savings can offset marginal energy or operating cost increases for particular wellness interventions. This paper presents a flexible, customizable framework to develop potential retrofit bundles and evaluate them considering economic, sustainability, wellness, risk and occupant experience factors to identify the optimal zone of retrofit. An illustrative case study using real building data demonstrates how the framework might be applied to a real project and customized to achieve unique stakeholder priorities.

  8. THE CO2 ABATEMENT POTENTIAL OF CALIFORNIA'S MID-SIZED COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Cardoso, Goncalo; Lipman, Tim; Megel, Olivier; Ganguly, Srirupa; Siddiqui, Afzal; Lai, Judy

    2009-12-31

    The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) todetermine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e. ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site?s annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB?s assumed utilization is far higher than is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at

  9. A Data Driven Pre-cooling Framework for Energy Cost Optimization in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Vishwanath, Arun; Chandan, Vikas; Mendoza, Cameron; Blake, Charles

    2017-05-16

    Commercial buildings consume significant amount of energy. Facility managers are increasingly grappling with the problem of reducing their buildings’ peak power, overall energy consumption and energy bills. In this paper, we first develop an optimization framework – based on a gray box model for zone thermal dynamics – to determine a pre-cooling strategy that simultaneously shifts the peak power to low energy tariff regimes, and reduces both the peak power and overall energy consumption by exploiting the flexibility in a building’s thermal comfort range. We then evaluate the efficacy of the pre-cooling optimization framework by applying it to building management system data, spanning several days, obtained from a large commercial building located in a tropical region of the world. The results from simulations show that optimal pre-cooling reduces peak power by over 50%, energy consumption by up to 30% and energy bills by up to 37%. Next, to enable ease of use of our framework, we also propose a shortest path based heuristic algorithmfor solving the optimization problemand show that it has comparable erformance with the optimal solution. Finally, we describe an application of the proposed optimization framework for developing countries to reduce the dependency on expensive fossil fuels, which are often used as a source for energy backup.We conclude by highlighting our real world deployment of the optimal pre-cooling framework via a software service on the cloud platform of a major provider. Our pre-cooling methodology, based on the gray box optimization framework, incurs no capital expense and relies on data readily available from a building management system, thus enabling facility managers to take informed decisions for improving the energy and cost footprints of their buildings

  10. Analysis of impact of large commercial aircraft on a prestressed containment building

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyoungsoo, E-mail: kylee@pvamu.edu [Center for Energy and Environmental Sustainability, Prairie View A and M University, Prairie view, TX, 77446 (United States); Han, Sang Eul, E-mail: hsang@inha.ac.kr [Department of Architectural Engineering, School of Architecture, Inha University, 253 Yonghyundong Nam-gu, Incheon, 402-751 (Korea, Republic of); Hong, Jung-Wuk, E-mail: j.hong@kaist.ac.kr [Department of Civil and Environmental Engineering, KAIST, 373-1 Guseon-dong, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

    2013-12-15

    Highlights: • Aircraft impact analyses are performed using the missile–target interaction method. • A large commercial B747 aircraft is considered with erosion effect. • The rigid wall impact test shows the validity of the developed aircraft model. • The parametric studies on the fictitious containment building are performed. • The plastic failure of the target is governed by the impulse of aircraft at the first momentum peak. - Abstract: In this paper, the results of nonlinear dynamic analyses of a concrete containment building under extreme loads are presented. The impact of a large commercial B747 airliner is investigated as the extreme load, and a rigid wall impact test is performed using commercial nonlinear finite element codes. The impact forces exerted by the aircraft are verified compared with the time-dependent impact force provided by OECD/NEA (2002), which was calculated based on the so-called Riera method. The rigid wall impact analysis shows that the finite element model of a B747 is appropriate for the purpose of the aircraft crash analysis exposed to the external hazard of “Beyond Design-Basis Events” defined by U.S. Nuclear Regulatory Commission. Finally, the applicability of this methodology is further studied and verified by conducting parametric studies on the critical infrastructures of nuclear power plant containment structures.

  11. ISO 50001 for Commercial Buildings: Lessons Learned From U.S. DOE Pilot Project: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Deru, M.; Field, K.; Punjabi, S.

    2014-08-01

    In the U.S., the ISO 50001 Standard, which establishes energy management systems (EnMSs) and processes, has shown uptake primarily in the industrial sector. The U.S. Department of Energy (DOE) undertook a pilot program to explore ISO 50001 implementation in commercial buildings. Eight organizations participated as pilots, with technical assistance provided by DOE, the National Renewable Energy Laboratory (NREL), the Lawrence Berkeley National Laboratory (LBNL), and the Georgia Institute of Technology (Georgia Tech). This paper shares important lessons learned from the pilot. Staff time was the most critical resource required to establish effective EnMSs in commercial buildings. The pilot also revealed that technical support and template/example materials were essential inputs. Crucial activities included evaluating performance, identifying goals, making connections, communicating operational controls, and tracking/reviewing progress. Benefits realized included enhanced intra-organizational connections, greater energy awareness, increased process efficiencies, and improved ability to make business cases. Incremental benefits for ISO 50001 certification were greater accountability, assurance of best practices, public relations opportunities, and potential to unlock verified savings credits or incentive money. Incremental certification costs included more staff/consultant time, money for certification, and a tendency to limit EnMS scope in order to ensure favorable audit results. Five best practices were identified - utilizing expert technical assistance, training, and other resources; focusing on implementation over documentation; keeping top management involved; considering organizational structure when selecting EnMS scope; and matching the implementation level to an EnMS's scope and scale. The last two practices are particularly relevant to the commercial buildings sector.

  12. Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Fisk, William J.

    2014-02-01

    Background - The goal of this project, with a focus on commercial buildings in California, was to develop a new framework for evidence-based minimum ventilation rate (MVR) standards that protect occupants in buildings while also considering energy use and cost. This was motivated by research findings suggesting that current prescriptive MVRs in commercial buildings do not provide occupants with fully safe and satisfactory indoor environments. Methods - The project began with a broad review in several areas ? the diverse strategies now used for standards or guidelines for MVRs or for environmental contaminant exposures, current knowledge about adverse human effects associated with VRs, and current knowledge about contaminants in commercial buildings, including their their presence, their adverse human effects, and their relationships with VRs. Based on a synthesis of the reviewed information, new principles and approaches are proposed for setting evidence-based VRs standards for commercial buildings, considering a range of human effects including health, performance, and acceptability of air. Results ? A review and evaluation is first presented of current approaches to setting prescriptive building ventilation standards and setting acceptable limits for human contaminant exposures in outdoor air and occupational settings. Recent research on approaches to setting acceptable levels of environmental exposures in evidence-based MVR standards is also described. From a synthesis and critique of these materials, a set of principles for setting MVRs is presented, along with an example approach based on these principles. The approach combines two sequential strategies. In a first step, an acceptable threshold is set for each adverse outcome that has a demonstrated relationship to VRs, as an increase from a (low) outcome level at a high reference ventilation rate (RVR, the VR needed to attain the best achievable levels of the adverse outcome); MVRs required to meet each

  13. Enabling Energy Efficiency in South Africa's Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    2016-04-01

    South Africa is leading a number of efforts to support a thriving economy while also reducing energy use. Increasing energy demand coupled with a highly energy intensive economy and energy inefficient industries provide the backdrop for strong government action underway in South Africa. This brochure details how the Clean Energy Solutions Center supported development of the Regulations on Allowance for the Energy Efficiency Savings legislation designed to provide a framework for effective energy efficiency regulation, incentives and energy reduction targets for South Africa's commercial buildings sector.

  14. General Electric Company proposed management plan, commercial buildings, National Solar Demonstration Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-04-01

    The National Solar Demonstration Plan (NSDP) for the solar heating and cooling of non-residential buildings is designed to meet the goals and objectives of ERDA 23A. The plan has been formulated for a matrix of two hundred (200) commercial demonstration projects. This report contains the General Electric recommendations for the NSDP pertaining to the management structure, demonstration implementation, schedules, data dissemination, and resource requirements. Closely associated with these major planning elements are the related elements in the other recent General Electric reports submitted under the SHACOB Phase I contract. (WDM)

  15. Analysis of Potential Free-Rider Eligibility for a Proposed Commercial Building Lighting Tax Deduction

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, David W.; Richman, Eric E.; Biyani, Rahul K.

    2004-09-30

    The report provides estimates of the potential volume of ''free riders'', in terms of both eligible square footage and associated available tax deductions, in a proposed commercial building lighting tax amendment to the 2003 Energy Bill. Determination of the actual tax rate for businesses and how the amendment may impact tax revenue collected by the treasury is beyond the scope of this effort. Others, such as the Treasury itself, are best equipped to make their own estimates of the eventual impact based on the total deductions available to taxable entities.

  16. Software-defined network abstractions and configuration interfaces for building programmable quantum networks

    Energy Technology Data Exchange (ETDEWEB)

    Dasari, Venkat [U.S. Army Research Laboratory, Aberdeen Proving Ground, MD; Sadlier, Ronald J [ORNL; Geerhart, Mr. Billy [U.S. Army Research Laboratory, Aberdeen Proving Ground, MD; Snow, Nikolai [U.S. Army Research Laboratory, Aberdeen Proving Ground, MD; Williams, Brian P [ORNL; Humble, Travis S [ORNL

    2017-01-01

    Well-defined and stable quantum networks are essential to realize functional quantum applications. Quantum networks are complex and must use both quantum and classical channels to support quantum applications like QKD, teleportation, and superdense coding. In particular, the no-cloning theorem prevents the reliable copying of quantum signals such that the quantum and classical channels must be highly coordinated using robust and extensible methods. We develop new network abstractions and interfaces for building programmable quantum networks. Our approach leverages new OpenFlow data structures and table type patterns to build programmable quantum networks and to support quantum applications.

  17. Software-defined network abstractions and configuration interfaces for building programmable quantum networks

    Science.gov (United States)

    Dasari, Venkat R.; Sadlier, Ronald J.; Geerhart, Billy E.; Snow, Nikolai A.; Williams, Brian P.; Humble, Travis S.

    2017-05-01

    Well-defined and stable quantum networks are essential to realize functional quantum communication applications. Quantum networks are complex and must use both quantum and classical channels to support quantum applications like QKD, teleportation, and superdense coding. In particular, the no-cloning theorem prevents the reliable copying of quantum signals such that the quantum and classical channels must be highly coordinated using robust and extensible methods. In this paper, we describe new network abstractions and interfaces for building programmable quantum networks. Our approach leverages new OpenFlow data structures and table type patterns to build programmable quantum networks and to support quantum applications.

  18. Review of Prior Commercial Building Energy Efficiency Retrofit Evaluation: A Report to Snohomish Public Utilities District

    Energy Technology Data Exchange (ETDEWEB)

    Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division

    2014-11-01

    Snohomish County Public Utilities District (the District or Snohomish PUD) provides electricity to about 325,000 customers in Snohomish County, Washington. The District has an incentive programs to encourage commercial customers to improve energy efficiency: the District partially reimburses the cost of approved retrofits if they provide a level of energy performance improvement that is specified by contract. In 2013 the District contracted with Lawrence Berkeley National Laboratory to provide a third-party review of the Monitoring and Verification (M&V) practices the District uses to evaluate whether companies are meeting their contractual obligations. This work helps LBNL understand the challenges faced by real-world practitioners of M&V of energy savings, and builds on a body of related work such as Price et al. (2013). The District selected a typical project for which they had already performed an evaluation. The present report includes the District's original evaluation as well as LBNL's review of their approach. The review is based on the document itself; on investigation of the load data and outdoor air temperature data from the building evaluated in the document; and on phone discussions with Bill Harris of the Snohomish County Public Utilities District. We will call the building studied in the document the subject building, the original Snohomish PUD report will be referred to as the Evaluation, and this discussion by LBNL is called the Review.

  19. CAN SORBENT-BASED GAS PHASE AIR CLEANING FOR VOCS SUBSTITUTE FOR VENTILATION IN COMMERCIAL BUILDINGS?

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Fisk, William J.

    2007-08-01

    This paper reviews current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings, as needed to enable reductions in ventilation rates and associated energy savings. The principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this application are summarized, and related priority research needs are identified. Major conclusions include: sorbent systems can remove a broad range of VOCs with moderate to high efficiency, sorbent technologies perform effectively when challenged with VOCs at the low concentrations present indoors, and there is a large uncertainty about the lifetime and associated costs of sorbent air cleaning systems when used in commercial buildings for indoor VOC control. Suggested priority research includes: experiments to determine sorbent system VOC removal efficiencies and lifetimes considering the broad range and low concentration of VOCs indoors; evaluations of in-situ regeneration of sorbents; and an updated analysis of the cost of sorbent air cleaning relative to the cost of ventilation.

  20. COMPREHENSIVE DIAGNOSTIC AND IMPROVEMENT TOOLS FOR HVAC-SYSTEM INSTALLATIONS IN LIGHT COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Abram Conant; Mark Modera; Joe Pira; John Proctor; Mike Gebbie

    2004-10-31

    Proctor Engineering Group, Ltd. (PEG) and Carrier-Aeroseal LLP performed an investigation of opportunities for improving air conditioning and heating system performance in existing light commercial buildings. Comprehensive diagnostic and improvement tools were created to address equipment performance parameters (including airflow, refrigerant charge, and economizer operation), duct-system performance (including duct leakage, zonal flows and thermal-energy delivery), and combustion appliance safety within these buildings. This investigation, sponsored by the National Energy Technology Laboratory, a division of the U.S. Department of Energy, involved collaboration between PEG and Aeroseal in order to refine three technologies previously developed for the residential market: (1) an aerosol-based duct sealing technology that allows the ducts to be sealed remotely (i.e., without removing the ceiling tiles), (2) a computer-driven diagnostic and improvement-tracking tool for residential duct installations, and (3) an integrated diagnosis verification and customer satisfaction system utilizing a combined computer/human expert system for HVAC performance. Prior to this work the aerosol-sealing technology was virtually untested in the light commercial sector--mostly because the savings potential and practicality of this or any other type of duct sealing had not been documented. Based upon the field experiences of PEG and Aeroseal, the overall product was tailored to suit the skill sets of typical HVAC-contractor personnel.

  1. Development of new methodologies for evaluating the energy performance of new commercial buildings

    Science.gov (United States)

    Song, Suwon

    The concept of Measurement and Verification (M&V) of a new building continues to become more important because efficient design alone is often not sufficient to deliver an efficient building. Simulation models that are calibrated to measured data can be used to evaluate the energy performance of new buildings if they are compared to energy baselines such as similar buildings, energy codes, and design standards. Unfortunately, there is a lack of detailed M&V methods and analysis methods to measure energy savings from new buildings that would have hypothetical energy baselines. Therefore, this study developed and demonstrated several new methodologies for evaluating the energy performance of new commercial buildings using a case-study building in Austin, Texas. First, three new M&V methods were developed to enhance the previous generic M&V framework for new buildings, including: (1) The development of a method to synthesize weather-normalized cooling energy use from a correlation of Motor Control Center (MCC) electricity use when chilled water use is unavailable, (2) The development of an improved method to analyze measured solar transmittance against incidence angle for sample glazing using different solar sensor types, including Eppley PSP and Li-Cor sensors, and (3) The development of an improved method to analyze chiller efficiency and operation at part-load conditions. Second, three new calibration methods were developed and analyzed, including: (1) A new percentile analysis added to the previous signature method for use with a DOE-2 calibration, (2) A new analysis to account for undocumented exhaust air in DOE-2 calibration, and (3) An analysis of the impact of synthesized direct normal solar radiation using the Erbs correlation on DOE-2 simulation. Third, an analysis of the actual energy savings compared to three different energy baselines was performed, including: (1) Energy Use Index (EUI) comparisons with sub-metered data, (2) New comparisons against

  2. Development of a methodology for defining whole-building energy design targets for commercial buildings: Phase 2, Development concept stage report

    Energy Technology Data Exchange (ETDEWEB)

    Jones, J.W. (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA (USA)); Deringer, J.J. (Deringer Group, Riva, MD (USA)); Hall, J.D. (American Inst. of Architects, Washington, DC (USA)) (comps.)

    1990-09-01

    The Whole-Building Energy Design Targets project is being conducted for the US Department of Energy (DOE) by the Pacific Northwest Laboratory (PNL). The objective of the project is to develop a flexible methodology for setting energy performance guidelines with which architects, engineers, planners, and owners can assess energy efficiency in commercial building design. This volume, the third in the four-volume report on the Targets project concept stage, contains the minutes of the workshops as well as summaries of the expert's written comments prepared at the close of each workshop. In Section 2, the building energy simulation workshop is summarized. Section 3 provides a summary of the building cost workshop.

  3. Estimates of U.S. Commercial Building Electricity Intensity Trends: Issues Related to End-Use and Supply Surveys

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, David B.

    2004-09-04

    This report examines measurement issues related to the amount of electricity used by the commercial sector in the U.S. and the implications for historical trends of commercial building electricity intensity (kWh/sq. ft. of floor space). The report compares two (Energy Information Administration) sources of data related to commercial buildings: the Commercial Building Energy Consumption Survey (CBECS) and the reporting by utilities of sales to commercial customers (survey Form-861). Over past two decades these sources suggest significantly different trend rates of growth of electricity intensity, with the supply (utility)-based estimate growing much faster than that based only upon the CBECS. The report undertakes various data adjustments in an attempt to rationalize the differences between these two sources. These adjustments deal with: 1) periodic reclassifications of industrial vs. commercial electricity usage at the state level and 2) the amount of electricity used by non-enclosed equipment (non-building use) that is classified as commercial electricity sales. In part, after applying these adjustments, there is a good correspondence between the two sources over the the past four CBECS (beginning with 1992). However, as yet, there is no satisfactory explanation of the differences between the two sources for longer periods that include the 1980s.

  4. The use of energy management and control systems to monitor the energy performance of commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Heinemeier, K E [Univ. of California, Berkeley, CA (United States). Dept. of Architecture

    1994-12-01

    Monitored data play a very important part in the implementation and evaluation of energy conservation technologies and programs. However, these data can be expensive to collect, so there is a need for lower-cost alternatives. In many situations, using the computerized Energy Management and Control Systems (EMCSs)--already installed in many buildings--to collect these commercial building performance data has advantages over more conventional methods. This method provides data without installing incremental hardware, and the large amounts of available operational data can be a very rich resource for understanding building performance. This dissertation addresses several of these issues. One specific objective is to describe a monitoring-project planning process that includes definition of objectives, constraints, resources and approaches for the monitoring. The choice of tools is an important part of this process. The dissertation goes on to demonstrate, through eight case studies, that EMCS monitoring is possible, and to identify and categorize the problems and issues that can be encountered. These issues lead to the creation, use, and testing of a set of methods for evaluation of EMCS monitoring, in the form of guidelines. Finally, EMCS monitoring is demonstrated and compared with conventional monitoring more methodically in a detailed case study.

  5. Characterization of changes in commercial building structure, equipment, and occupants: End-Use Load and Consumer Assessment Program

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, R.G.; Taylor, Z.T.; Miller, N.E.; Pratt, R.G.

    1990-12-01

    Changes in commercial building structure, equipment, and occupants result in changes in building energy use. The frequency and magnitude of those changes have substantial implications for conservation programs and resource planning. For example, changes may shorten the useful lifetime of a conservation measure as well as impact the savings from that measure. This report summarizes the frequency of changes in a commercial building sample that was end-use metered under the End-Use Load and Consumer Assessment Program (ELCAP). The sample includes offices, dry good retails, groceries, restaurants, warehouses, schools, and hotels. Two years of metered data, site visit records, and audit data were examined for evidence of building changes. The observed changes were then classified into 12 categories, which included business type, equipment, remodel, vacancy, and operating schedule. The analysis characterized changes in terms of frequency of types of change; relationship to building vintage and floor area; and variation by building type. The analysis also examined the energy impacts of various changes. The analysis determined that the rate of change in commercial buildings is high--50% of the buildings experienced one type of change during the 2 years for which monitoring data were examined. Equipment changes were found to be most frequent in offices and retail stores. Larger, older office buildings tend to experience a wider variety of changes more frequently than the smaller, newer buildings. Key findings and observations are presented in Section 2. Section 3 provides the underlying motivation and objectives. In Section 4, the methodology used is documented, including the commercial building sample and the data sources used. Included are the definitions of change events and the overall approach taken. Results are analyzed in Section 5, with additional technical details in Appendixes. 2 refs., 46 figs., 22 tabs. (JF)

  6. Carousel Trackers with 1-Sun or 3-Sun Modules for Commercial Building Rooftops

    Energy Technology Data Exchange (ETDEWEB)

    Gehl, Anthony C [ORNL; Maxey, L Curt [ORNL; Fraas, Dr. Lewis [JX Crystals, Inc.; Avery, James E. [JX Crystals, Inc.; Minkin, Leonid M [ORNL; Huang, H, [JX Crystals, Inc.

    2008-01-01

    The goal is lower cost solar electricity. Herein, two evolutional steps are described toward achieving this goal. The first step is to follow the sun with a solar tracker. Herein, a carousel tracker is described for mounting on commercial building flat rooftops in order to produce more kWh per kW relative to fixed PV modules. The second evolutionary improvement is to produce lower cost 3-sun CPV modules where two thirds of the expensive single crystal silicon material is replaced by less expensive mirror material. This paper describes the performance and durability of two prototype installations demonstrating these evolutionary innovations. In the first case, the installation and operation of 2 carousels equipped with traditional flat plate modules is described. In the second case, the operation of a carousel equipped with new 3-sun CPV modules is described. Both systems have been operating as expected for several months through the winter of 2007.

  7. VOLTTRON™: Tech-to-Market Best-Practices Guide for Small- and Medium-Sized Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Haack, Jereme N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Nicholls, Andrew K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-07-11

    VOLTTRON™ is an open-source distributed control and sensing platform developed by Pacific Northwest National Laboratory for the U.S. Department of Energy. It was developed to be used by the Office of Energy Efficiency and Renewable Energy to support transactive controls research and deployment activities. VOLTTRON is designed to be an overarching integration platform that could be used to bring together vendors, users, and developers and enable rapid application development and testing. The platform is designed to support modern control strategies, including the use of agent- and transaction-based controls. It also is designed to support the management of a wide range of applications, including heating, ventilation, and air-conditioning systems; electric vehicles; and distributed-energy and whole-building loads. This report was completed as part of the Building Technologies Office’s Technology-to-Market Initiative for VOLTTRON’s Market Validation and Business Case Development efforts. The report provides technology-to-market guidance and best practices related to VOLTTRON platform deployments and commercialization activities for use by entities serving small- and medium-sized commercial buildings. The report characterizes the platform ecosystem within the small- and medium-sized commercial building market and articulates the value proposition of VOLTTRON for three core participants in this ecosystem: 1) platform owners/adopters, 2) app developers, and 3) end-users. The report also identifies key market drivers and opportunities for open platform deployments in the small- and medium-sized commercial building market. Possible pathways to the market are described—laboratory testing to market adoption to commercialization. We also identify and address various technical and market barriers that could hinder deployment of VOLTTRON. Finally, we provide “best practice” tech-to-market guidance for building energy-related deployment efforts serving small- and

  8. A comprehensive framework to assess, model, and enhance the human role in conserving energy in commercial buildings

    Science.gov (United States)

    Azar, Elie

    Energy conservation and sustainability are subjects of great interest today, especially in the commercial building sector which is witnessing a very high and growing demand for energy. Traditionally, efforts to reduce energy consumption in this sector consisted of researching and developing energy efficient building technologies and systems. On the other hand, recent studies indicate that human actions are major determinants of building energy performance and can lead to excessive energy use even in advanced low-energy buildings. As a result, it is essential to determine if the approach to future energy reduction initiatives should remain solely technology-focused, or if a human-focused approach is also needed to complement advancements in technology and improve building operation and performance. In practice, while technology-focused solutions have been extensively researched, promoted, and adopted in commercial buildings, research efforts on the role of human actions and energy use behaviors in energy conservation remain very limited. This study fills the missing gap in literature by presenting a comprehensive framework to (1) understand and quantify the influence of human actions on building energy performance, (2) model building occupants' energy use behaviors and account for potential changes in these behaviors over time, and (3) test and optimize different human-focused energy reduction interventions to increase their adoption in commercial buildings. Results are significant and prove that human actions have a major role to play in reducing the energy intensity of the commercial building sector. This sheds the light on the need for a shift in how people currently use and control different buildings systems, as this is crucial to ensure efficient building operation and to maximize the return on investment in energy-efficient technologies. Furthermore, this study proposes methods and tools that can be applied on any individual or groups of commercial buildings

  9. Assessing Energy Efficiency Opportunities in US Industrial and Commercial Building Motor Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Prakash; Sheaffer, Paul; McKane, Aimee; Scheihing, Paul

    2015-09-01

    In 2002, the United States Department of Energy (USDOE) published an energy efficiency assessment of U.S. industrial sector motor systems titled United States Industrial Electric Motor Systems Market Opportunities Assessment. The assessment advanced motor system efficiency by providing a greater understanding of the energy consumption, use characteristics, and energy efficiency improvement potential of industrial sector motor systems in the U.S. Since 2002, regulations such as Minimum Energy Performance Standards, cost reductions for motor system components such as variable frequency drives, system-integrated motor-driven equipment, and awareness programs for motor system energy efficiency have changed the landscape of U.S. motor system energy consumption. To capture the new landscape, the USDOE has initiated a three-year Motor System Market Assessment (MSMA), led by Lawrence Berkeley National Laboratory (LBNL). The MSMA will assess the energy consumption, operational and maintenance characteristics, and efficiency improvement opportunity of U.S. industrial sector and commercial building motor systems. As part of the MSMA, a significant effort is currently underway to conduct field assessments of motor systems from a sample of facilities representative of U.S. commercial and industrial motor system energy consumption. The Field Assessment Plan used for these assessments builds on recent LBNL research presented at EEMODS 2011 and EEMODS 2013 using methods for characterizing and determining regional motor system energy efficiency opportunities. This paper provides an update on the development and progress of the MSMA, focusing on the Field Assessment Plan and the framework for assessing the global supply chain for emerging motors and drive technologies.

  10. Destruction of Spores on Building Decontamination Residue in a Commercial Autoclave▿

    Science.gov (United States)

    Lemieux, P.; Sieber, R.; Osborne, A.; Woodard, A.

    2006-01-01

    The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 106 spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in2 and 275°F and 75 min at 45 lb/in2 and 292°F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in2 and 275°F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process. PMID:17012597

  11. A microsystem integration platform dedicated to build multi-chip-neural interfaces.

    Science.gov (United States)

    Ayoub, Amer E; Gosselin, Benoit; Sawan, Mohamad

    2007-01-01

    In this paper, we present an electrical discharge machining (EDM) technique associated with electrochemical steps to construct an appropriate biological interface to neural tissues. The presented microprobe design permits to short the time of production compared to available techniques, while improving the integrity of the electrodes. In addition, we are using a 3D approach to create compact and independent microsystem integration platefrom incorporating array of electrodes and signal processing chips. System-in-package and die-stacking are used to connect the integrated circuits and the array of electrodes on the platform. This approach enables to build a device that will fit in a volume smaller than 1.7 x 1.7 x 3.0 mm(3). This demonstrates the possibility of creating small devices that are suitable to fit in restricted areas for interfacing the brain.

  12. Comparisons of Two Commercial and Two Low-cost Interfaces for Virtual Skiing

    DEFF Research Database (Denmark)

    Nilsson, Niels Chr.; Serafin, Stefania; Nordahl, Rolf

    2015-01-01

    In this paper we present two comparisons of two novel physical interface for interacting with a virtual environment in the form of a skiing game. The interfaces were compared through two separate within-subjects studies. In the first study we compared a wobble board augmented with a low-cost 3D...

  13. Closing the Loop with Sensors in Commercial Building Systems: Applying Lessons from Automotive Vehicles

    Science.gov (United States)

    Mantese, Joseph

    2011-08-01

    Automotive systems have evolved extensively over the past 50 years, providing a fully integrated system of sub-systems that work in concert for optimal vehicle level closed loop control. In this talk we look at several automotive sub-systems: stability and control, safety and security, emissions and comfort, diagnostics and maintenance, infotainment and communications; with an eye toward understanding their technology drivers and associated value propositions. Conversely, we examine how commercial building systems currently are represented as a collection of sub-systems that often work independently of each other for local optimization, often relying upon open loop control systems developed and installed decades ago. Reasoning primarily by analogy we explore opportunities for energy and efficiency, comfort and environment, and safety/security; asking whether there is sufficient value associated with a new class of building sensors and how those technologies might be brought to bear in improving performance. Finally, we examine the fundamental architecture of detection systems built upon sensing elements, with the aim of understanding trade-offs between: detection, false alarm rate, power, and cost.

  14. Distributed Energy Resources On-Site Optimization for Commercial Buildings with Electric and Thermal Storage Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Lacommare, Kristina S H; Stadler, Michael; Aki, Hirohisa; Firestone, Ryan; Lai, Judy; Marnay, Chris; Siddiqui, Afzal

    2008-05-15

    The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic as well as environmental attractiveness of on-site generation (e.g., PV, fuel cells, reciprocating engines or microturbines operating with or without CHP) and contribute to enhanced demand response. In order to examine the impact of storage technologies on demand response and carbon emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that has the minimization of annual energy costs as its objective function. By implementing this approach in the General Algebraic Modeling System (GAMS), the problem is solved for a given test year at representative customer sites, such as schools and nursing homes, to obtain not only the level of technology investment, but also the optimal hourly operating schedules. This paper focuses on analysis of storage technologies in DER optimization on a building level, with example applications for commercial buildings. Preliminary analysis indicates that storage technologies respond effectively to time-varying electricity prices, i.e., by charging batteries during periods of low electricity prices and discharging them during peak hours. The results also indicate that storage technologies significantly alter the residual load profile, which can contribute to lower carbon emissions depending on the test site, its load profile, and its adopted DER technologies.

  15. Duct leakage impacts on VAV system performance in California large commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.; Matson, Nance E.

    2003-10-01

    The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. Based on our analyses of the 54 simulation cases, the increase in annual fan energy is estimated to be 40 to 50% for a system with a total leakage of 19% at design conditions compared to a tight system with 5% leakage. Annual cooling plant energy also increases by about 7 to 10%, but reheat energy decreases (about 3 to 10%). In combination, the increase in total annual HVAC site energy is 2 to 14%. The total HVAC site energy use includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption. Using year 2000 average commercial sector energy prices for California ($0.0986/kWh and $7.71/Million Btu), the energy increases result in 9 to 18% ($7,400 to $9,500) increases in HVAC system annual operating costs. Normalized by duct surface area, the increases in annual operating costs are 0.14 to 0.18 $/ft{sup 2}. Using a suggested one-time duct sealing cost of $0.20 per square foot of duct surface area, these results indicate that sealing leaky ducts in VAV systems has a simple payback period of about 1.3 years. Even with total leakage rates as low as 10%, duct sealing is still cost effective. This suggests that duct sealing should be considered at least for VAV systems with 10% or more total duct

  16. Development of a commercial building/site evaluation framework for minimizing energy consumption and greenhouse gas emissions of transportation and building systems

    Science.gov (United States)

    Weigel, Brent A.

    In urbanized areas, building and transportation systems generally comprise the majority of energy consumption and greenhouse gas (GHG) emissions. Realization of global environmental sustainability depends upon efficiency improvements of building and transportation systems in the built environment. The selection of efficient buildings and locations can help to improve the efficient utilization of transportation and building systems. Green building design and rating frameworks provide some guidance and incentive for the development of more efficient building and transportation systems. However, current frameworks are based primarily on prescriptive, component standards, rather than performance-based, whole-building evaluations. This research develops a commercial building/site evaluation framework for the minimization of energy consumption and GHG emissions of transportation and building systems through building/site selection. The framework examines, under uncertainty, multiple dimensions of building/site operation efficiencies: transportation access to/from a building site; heating, ventilation, air conditioning, and domestic hot water; interior and exterior lighting; occupant conveyances; and energy supply. With respect to transportation systems, the framework leverages regional travel demand model data to estimate the activity associated with home-based work and non-homebased work trips. A Monte Carlo simulation approach is used to quantify the dispersion in the estimated trip distances, travel times, and mode choice. The travel activity estimates are linked with a variety of existing calculation resources for quantifying energy consumption and GHG emissions. With respect to building systems, the framework utilizes a building energy simulation approach to estimate energy consumption and GHG emissions. The building system calculation procedures include a sensitivity analysis and Monte Carlo analysis to account for the impacts of input parameter uncertainty on

  17. Development of a Service Quality Scale for Multiple Technology Interfaces in Commercial Banking

    Directory of Open Access Journals (Sweden)

    JAYA SANGEETHA

    2012-12-01

    Full Text Available The objective of this paper is to develop a service quality scale by identifying the dimensions affecting the service quality across various technology interfaces in retail banking. The paper examines the literature involving the various technology interfaces and aims to propose a conceptual model involving dimensions that affect the perceptions of service quality of the technology interfaces used in banks. The paper also seeks to establish the psychometric properties of the scale thus arrived. The literature review reveals that the models currently available to measure the service quality of the technology interfaces are limited in their focus, encompassing mostly one electronic channel – the internet – and few others studying the ATM and telephone banking cha nnels. However, there is a gap with regard to the study of other technology interfaces like call centers and queue systems used in the branches. In this study, an attempt is being made to explore the influence of the various technology interfaces on banks’ service quality like the ATM, telephone banking, call center services, queue systems in the branches etc. which the customers use in combination and thereby to develop a scale to measure technology interface service quality (TISQ.

  18. Comparisons of Two Commercial and Two Low-cost Interfaces for Virtual Skiing

    DEFF Research Database (Denmark)

    Nilsson, Niels Chr.; Serafin, Stefania; Nordahl, Rolf

    2015-01-01

    In this paper we present two comparisons of two novel physical interface for interacting with a virtual environment in the form of a skiing game. The interfaces were compared through two separate within-subjects studies. In the first study we compared a wobble board augmented with a low-cost 3D...... accelerometer with the Wii Balance Board, and in the second study we compared a step machine augmented with the same accelerometer with the Wii Balance Board. Keyboard and mouse peripherals were included in both studies in order to see how the novel interfaces and the Wii Balance Board would measure up against...

  19. Toward the Holy Grail of Perfect Information: Lessons Learned Implementing an Energy Information System in a Commercial Building

    Energy Technology Data Exchange (ETDEWEB)

    Kircher, Kevin; Ghatikar, Girish; Greenberg, Steve; Watson, Dave; Diamond, Rick; Sartor, Dale; Federspiel, Cliff; McEachern, Alex; Owen, Tom

    2010-05-14

    Energy information systems (real-time acquisition, analysis, and presentation of information from energy end-uses) in commercial buildings have demonstrated value as tools for improving energy efficiency and thermal comfort. These improvements include characterization through benchmarking, identification of retrofit opportunities, anomaly detection to inform retro-commissioning, and feedback to occupants to encourage shifts in behavior. Energy information systems can play a vital role in achieving a variety of ambitious sustainability goals for the existing stock of commercial buildings, but their implementation is often fraught with pitfalls. In this paper, we present a case study of an EIS and sub-metering project executed in a representative commercial office building. We describe the building, highlight a few of its problems, and detail the hardware and software technologies we employed to address them. We summarize the difficulties encountered and lessons learned, and suggest general guidelines for future EIS projects to improve performance and save energy in the commercial building fleet. These guidelines include measurement criteria, monitoring strategies, and analysis methods. In particular, we propose processes for: - Defining project goals, - Selecting end-use targets and depth of metering, - Selecting contractors and software vendors, - Installing and networking measurement devices, - Commissioning and using the energy information system.

  20. Energy Management in Small Commercial Buildings: A Look at How HVAC Contractors Can Deliver Energy Efficiency to this Segment

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin; Granderson, Jessica; Mathew, Paul

    2014-07-01

    While buildings smaller than 50,000 sq ft account for nearly half of the energy used in US commercial buildings, energy efficiency programs to-date have primarily focused on larger buildings. Interviews with stakeholders and a review of the literature indicate interest in energy efficiency from the small commercial building sector, provided solutions are simple and low-cost. An approach to deliver energy management to small commercial buildings via HVAC contractors and preliminary demonstration findings are presented. The energy management package (EMP) developed includes five technical elements: benchmarking and analysis of monthly energy use; analysis of interval electricity data (if available), a one-hour onsite walkthrough, communication with the building owner, and checking of results. This data-driven approach tracks performance and identifies low-cost opportunities, using guidelines and worksheets for each element to streamline the delivery process and minimize the formal training required. This energy management approach is unique from, but often complementary to conventional quality maintenance or retrofit-focused programs targeting the small commercial segment. Because HVAC contractors already serve these clients, the transaction cost to market and deliver energy management services can be reduced to the order of hundreds of dollars per year. This business model, outlined briefly in this report, enables the offering to benefit the contractor and client even at the modest expected energy savings in small buildings. Results from a small-scale pilot of this approach validated that the EMP could be delivered by contractors in 4-8 hours per building per year, and that energy savings of 3-5percent are feasible through this approach.

  1. Computer Modeling VRF Heat Pumps in Commercial Buildings using EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Raustad, Richard

    2013-07-01

    Variable Refrigerant Flow (VRF) heat pumps are increasingly used in commercial buildings in the United States. Monitored energy use of field installations have shown, in some cases, savings exceeding 30% compared to conventional heating, ventilating, and air-conditioning (HVAC) systems. A simulation study was conducted to identify the installation or operational characteristics that lead to energy savings for VRF systems. The study used the Department of Energy EnergyPlus? building simulation software and four reference building models. Computer simulations were performed in eight U.S. climate zones. The baseline reference HVAC system incorporated packaged single-zone direct-expansion cooling with gas heating (PSZ-AC) or variable-air-volume systems (VAV with reheat). An alternate baseline HVAC system using a heat pump (PSZ-HP) was included for some buildings to directly compare gas and electric heating results. These baseline systems were compared to a VRF heat pump model to identify differences in energy use. VRF systems combine multiple indoor units with one or more outdoor unit(s). These systems move refrigerant between the outdoor and indoor units which eliminates the need for duct work in most cases. Since many applications install duct work in unconditioned spaces, this leads to installation differences between VRF systems and conventional HVAC systems. To characterize installation differences, a duct heat gain model was included to identify the energy impacts of installing ducts in unconditioned spaces. The configuration of variable refrigerant flow heat pumps will ultimately eliminate or significantly reduce energy use due to duct heat transfer. Fan energy is also studied to identify savings associated with non-ducted VRF terminal units. VRF systems incorporate a variable-speed compressor which may lead to operational differences compared to single-speed compression systems. To characterize operational differences, the computer model performance curves used

  2. Tcl/Tk with DRAMA - A Natural for Building User Interfaces to Instrumentation Systems?

    Science.gov (United States)

    Farrell, T. J.; Bailey, J. A.; Shortridge, K.

    DRAMA allows you to build distributed real-time systems consisting of a set of event-driven tasks. The Tk windowing system is also event-driven---like most windowing systems. The similarities between the two have allowed them to be merged extremely effectively, providing an almost seamless interface between the two. The control system for the AAO's 2dF project has instrument control tasks written using DRAMA and running on VMS, UNIX, and VxWorks systems. These are tested and controlled by higher-level tasks whose user interfaces are provided by Tcl/Tk and which communicate with the rest of the system using purpose-built Tcl commands that invoke the DRAMA system routines. This gives the critical instrument control tasks the fixed nature and reliability that comes from a compiled, linked system, while allowing a very flexible user interface and test system that takes advantage of the ease of modification and the flexibility of an interactive language like Tcl/Tk.

  3. Walmart - Saving Energy, Saving Money Through Comprehensive Retrofits, Commercial Building Energy Efficiency (Fact Sheet); Energy Efficiency & Renewable Energy (EERE)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-01

    Walmart partnered with the U.S. Department of Energy (DOE) in 2009 to develop and demonstrate energy retrofits for existing buildings. The goal was to reduce energy consumption by at least 30% versus ASHRAE Standard 90.1-2007, as part of DOE's Commercial Building Partnerships (CBP) Program. The project presented here, the retrofit of a 213,000 square foot store in Centennial, Colorado, withefficiency measures across multiple building systems, is part of Walmart's ongoing environmental sustainability program, which originated in 2005.

  4. Engineering and commercialization of human-device interfaces, from bone to brain.

    Science.gov (United States)

    Knothe Tate, Melissa L; Detamore, Michael; Capadona, Jeffrey R; Woolley, Andrew; Knothe, Ulf

    2016-07-01

    Cutting edge developments in engineering of tissues, implants and devices allow for guidance and control of specific physiological structure-function relationships. Yet the engineering of functionally appropriate human-device interfaces represents an intractable challenge in the field. This leading opinion review outlines a set of current approaches as well as hurdles to design of interfaces that modulate transfer of information, i.a. forces, electrical potentials, chemical gradients and haptotactic paths, between endogenous and engineered body parts or tissues. The compendium is designed to bridge across currently separated disciplines by highlighting specific commonalities between seemingly disparate systems, e.g. musculoskeletal and nervous systems. We focus on specific examples from our own laboratories, demonstrating that the seemingly disparate musculoskeletal and nervous systems share common paradigms which can be harnessed to inspire innovative interface design solutions. Functional barrier interfaces that control molecular and biophysical traffic between tissue compartments of joints are addressed in an example of the knee. Furthermore, we describe the engineering of gradients for interfaces between endogenous and engineered tissues as well as between electrodes that physically and electrochemically couple the nervous and musculoskeletal systems. Finally, to promote translation of newly developed technologies into products, protocols, and treatments that benefit the patients who need them most, regulatory and technical challenges and opportunities are addressed on hand from an example of an implant cum delivery device that can be used to heal soft and hard tissues, from brain to bone. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  5. Greenhouse Gas Abatement with Distributed Generation in California's Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Cardoso, Goncalo; Megel, Olivier; Siddiqui, Afzal; Lai, Judy

    2009-08-15

    Lawrence Berkeley National Laboratory (LBL) is working with the California Energy Commission (CEC) to determine the role of distributed generation (DG) in greenhouse gas reductions. The impact of DG on large industrial sites is well known, and mostly, the potentials are already harvested. In contrast, little is known about the impact of DG on commercial buildings with peak electric loads ranging from 100 kW to 5 MW. We examine how DG with combined heat and power (CHP) may be implemented within the context of a cost minimizing microgrid that is able to adopt and operate various smart energy technologies, such as thermal and photovoltaic (PV) on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We use a mixed-integer linear program (MILP) that has the minimization of a site's annual energy costs as objective. Using 138 representative commercial sites in California (CA) with existing tariff rates and technology data, we find the greenhouse gas reduction potential for California's commercial sector. This paper shows results from the ongoing research project and finished work from a two year U.S. Department of Energy research project. To show the impact of the different technologies on CO2 emissions, several sensitivity runs for different climate zones within CA with different technology performance expectations for 2020 were performed. The considered sites can contribute between 1 Mt/a and 1.8 Mt/a to the California Air Resources Board (CARB) goal of 6.7Mt/a CO2 abatement potential in 2020. Also, with lower PV and storage costs as well as consideration of a CO2 pricing scheme, our results indicate that PV and electric storage adoption can compete rather than supplement each other when the tariff structure and costs of electricity supply have been taken into consideration. To satisfy the site's objective of minimizing energy costs, the batteries will be charged also by CHP systems during off-peak and mid

  6. Evaluation of Different EEG Acquisition Systems Concerning Their Suitability for Building a Brain–Computer Interface: Case Studies

    Science.gov (United States)

    Pinegger, Andreas; Wriessnegger, Selina C.; Faller, Josef; Müller-Putz, Gernot R.

    2016-01-01

    One important aspect in non-invasive brain–computer interface (BCI) research is to acquire the electroencephalogram (EEG) in a proper way. From an end-user perspective, it means with maximum comfort and without any extra inconveniences (e.g., washing the hair), whereas from a technical perspective, the signal quality has to be optimal to make the BCI work effectively and efficiently. In this work, we evaluated three different commercially available EEG acquisition systems that differ in the type of electrodes (gel-, water-, and dry-based), the amplifier technique, and the data transmission method. Every system was tested regarding three different aspects, namely, technical, BCI effectiveness and efficiency (P300 communication and control), and user satisfaction (comfort). We found that water-based system had the lowest short circuit noise level, the hydrogel-based system had the highest P300 spelling accuracies, and the dry electrode-based system caused the least inconveniences. Therefore, building a reliable BCI is possible with all the evaluated systems, and it is on the user to decide which system meets the given requirements best. PMID:27746714

  7. On Signage System in Commercial Building%商业建筑标识系统探析

    Institute of Scientific and Technical Information of China (English)

    蔡乙亿; 周强

    2013-01-01

    The importance of signage system in commercial building is analyzed. In such kind of buildings, the function of signage system is to guide the clear direction in commercial building, convey visual information and serve as a signage system element of the commercial complex as well. Based on the analysis on consumer psychology, design method of signage system in commercial building is discussed.%该文探析了标识系统在商业街建筑中的重要性。在商业建筑中,标识系统不仅具有导向性,在商业建筑环境中起到明确方向,指明地点的作用,还具有视觉信息传达功能,并可以作为一个商业综合体的识别系统元素。该文在对消费心理分析的基础上探讨了商业建筑中标识系统的设计方法。

  8. Examination of the technical potential of near-infrared switching thermochromic windows for commercial building applications

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Sabine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Building Technology and Urban Systems Dept.. Environmental Energy Technologies Division; Lee, Eleanor S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Building Technology and Urban Systems Dept.. Environmental Energy Technologies Division; Clavero, César [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Building Technology and Urban Systems Dept.. Environmental Energy Technologies Division

    2014-01-29

    Current thermochromic windows modulate solar transmission primarily within the visible range, resulting in reduced space-conditioning energy use but also reduced daylight, thereby increasing lighting energy use compared to conventional static, near-infrared selective, low-emittance windows. To better understand the energy savings potential of improved thermochromic devices, a hypothetical near-infrared switching thermochromic glazing was defined based on guidelines provided by the material science community. In this paper, EnergyPlus simulations were conducted on a prototypical large office building and a detailed analysis was performed showing the progression from switching characteristics to net window heat flow and perimeter zone loads and then to perimeter zone heating, ventilation, and air-conditioning (HVAC) and lighting energy use for a mixed hot/cold climate and a hot, humid climate in the US. When a relatively high daylight transmission is maintained when switched (Tsol=0.10–0.50 and Tvis=0.30–0.60) and if coupled with a low-e inboard glazing layer (e=0.04), the hypothetical thermochromic window with a low critical switching temperature range (14–20 °C) achieved reductions in total site annual energy use of 14.0–21.1 kW h/m2-floor-yr or 12–14% for moderate- to large-area windows (WWR≥0.30) in Chicago and 9.8–18.6 kW h/m2-floor-yr or 10–17% for WWR≥0.45 in Houston compared to an unshaded spectrally-selective, low-e window (window E1) in south-, east-, and west-facing perimeter zones. Finally, if this hypothetical thermochromic window can be offered at costs that are competitive to conventional low-e windows and meet esthetic requirements defined by the building industry and end users, then the technology is likely to be a viable energy-efficiency option for internal load dominated commercial buildings.

  9. Comparisons of Two Commercial and Two Low-cost Interfaces for Virtual Skiing

    DEFF Research Database (Denmark)

    Nilsson, Niels Chr.; Serafin, Stefania; Nordahl, Rolf

    2015-01-01

    accelerometer with the Wii Balance Board, and in the second study we compared a step machine augmented with the same accelerometer with the Wii Balance Board. Keyboard and mouse peripherals were included in both studies in order to see how the novel interfaces and the Wii Balance Board would measure up against...... these commonly used input devices. The interfaces were evaluated in terms of performance, perceived ease of use, and enjoyment. The results of the first study show that participants reported the wobble board to be the hardest to control, although their performance was better than using the Wii Balance Board...

  10. An analysis of the benefits of photovoltaic-coated glazing on owning and operating costs of high rise commercial buildings

    Science.gov (United States)

    Sylvester, Keith Everette

    Energy efficient glazing is necessary to reduce heat gains or losses that contribute to the high-energy use of buildings. However, high-rise commercial buildings that use energy efficient glazing are still consumptive. To reduce their energy use further, recent studies have integrated photovoltaic glazed window systems into the building shell. With limited light transmittance due to their required production of electricity, photovoltaic glazed windows can be developed with thermal properties similar to Low-E coatings. Consequently, these window systems can reduce operating costs of buildings without reducing the human satisfaction of the built environment. To understand the relationship between photovoltaic windows, energy use and human satisfaction, this study investigates the effects of photovoltaic glazed windows on energy use of large commercial buildings and includes an assessment of the overall human satisfaction of the workers within photovoltaic glazed office spaces. This study targets high-rise commercial buildings and their occupants in urban centers of the four census regions---North, Northeast, South, and Midwest. A prototypical building was used to develop the base case simulations for the DOE-2 energy simulation program and the PV F-Chart photovoltaic analysis program. By substituting the appropriate variable in the base case simulation for each site, building was simulated to evaluate the impact of the PV glazing on the building's heat loss/gaining as well as the amount of electricity that could be expected from the PV. To test for human satisfaction, a survey was performed to assess the overall preference of the subjects to the office spaces using the photovoltaic glazed windows. An analysis of the variance was also conducted to test for significantly different treatment means. Overall, the findings of this study show that photovoltaic windows significantly decrease the energy used by high-rise commercial buildings. Payback periods 11 to 20 years

  11. The application of photovoltaic roof shingles to residential and commercial buildings

    Science.gov (United States)

    Shepard, N. F., Jr.; Sanchez, L. E.

    1978-01-01

    The recent development of a shingle-type solar-cell module makes it possible to incorporate easily photovoltaic power generation into the sloping roofs of residential or commercial buildings. These modules, which use a closely packed array of nineteen 53-mm-diameter circular solar cells, are capable of producing 101 watts/sq m of module area under standard operating conditions. This module performance is achievable by the use of solar cells with an average efficiency of 13.3 percent at 1 kW/sq m air-mass-1.5 insolation and at a cell temperature of 28 C. When these modules are mounted on a sloping south-facing roof which is insulated on the rear surface, the annual energy generated at the maximum power operating point will vary from 255.6 to 137.3 kWh/sq m of module area depending on the site location, with Albuquerque, NM, and Seattle, WA, representing the highest and lowest values of the thirteen sites considered.

  12. Natural radioactivity in different commercial ceramic samples used in Yemeni buildings

    Science.gov (United States)

    Amin, Sahar A.; Naji, Mustafa

    2013-05-01

    In this work we calculated the radioactivity concentrations of the natural radioactive nuclides 238U, 232Th, 226Ra and 40K for 10 commercial samples collected from 10 different companies which are used in the construction of Yemeni buildings. Gamma ray spectroscopy was used to analyze the samples and the concentrations of radioisotopes were determined using a hyper-pure germanium (HPGe) detector in Bq/kg dry-weight. The average concentrations of 238U, 232Th, 226Ra and 40K were found to be 131.4, 83.55, 131.88 and 400.7 Bq/kg respectively. Different hazard indices were also determined. The results showed that the average radium equivalent activity (Raeq), the absorbed dose rate (Dr), the annual effective dose equivalent (AEDE), the external hazard index (Hex) and representation level index (Iγ) were: 307.52 Bq/kg, 139.31 nGy/h, 1.40 mSv/yr, 0.83 and 2.15 respectively. The mean value of (Raeq) obtained in this study is in good agreement with that of the international value while the mean values of the other indices are found to be higher than the international reference values. The measured activity concentrations for these radionuclide were compared with the reported data obtained from similar materials used in other countries.

  13. Control of disturbing loads in residential and commercial buildings via geometric algebra.

    Science.gov (United States)

    Castilla, Manuel-V

    2013-01-01

    Many definitions have been formulated to represent nonactive power for distorted voltages and currents in electronic and electrical systems. Unfortunately, no single universally suitable representation has been accepted as a prototype for this power component. This paper defines a nonactive power multivector from the most advanced multivectorial power theory based on the geometric algebra (GA). The new concept can have more importance on harmonic loads compensation, identification, and metering, between other applications. Likewise, this paper is concerned with a pioneering method for the compensation of disturbing loads. In this way, we propose a multivectorial relative quality index δ(~) associated with the power multivector. It can be assumed as a new index for power quality evaluation, harmonic sources detection, and power factor improvement in residential and commercial buildings. The proposed method consists of a single-point strategy based of a comparison among different relative quality index multivectors, which may be measured at the different loads on the same metering point. The comparison can give pieces of information with magnitude, direction, and sense on the presence of disturbing loads. A numerical example is used to illustrate the clear capabilities of the suggested approach.

  14. A Review of Approaches for Sensing, Understanding, and Improving Occupancy-Related Energy-Use Behaviors in Commercial Buildings

    Directory of Open Access Journals (Sweden)

    Hamed Nabizadeh Rafsanjani

    2015-10-01

    Full Text Available Buildings currently account for 30–40 percent of total global energy consumption. In particular, commercial buildings are responsible for about 12 percent of global energy use and 21 percent of the United States’ energy use, and the energy demand of this sector continues to grow faster than other sectors. This increasing rate therefore raises a critical concern about improving the energy performance of commercial buildings. Recently, researchers have investigated ways in which understanding and improving occupants’ energy-consuming behaviors could function as a cost-effective approach to decreasing commercial buildings’ energy demands. The objective of this paper is to present a detailed, up-to-date review of various algorithms, models, and techniques employed in the pursuit of understanding and improving occupants’ energy-use behaviors in commercial buildings. Previous related studies are introduced and three main approaches are identified: (1 monitoring occupant-specific energy consumption; (2 Simulating occupant energy consumption behavior; and (3 improving occupant energy consumption behavior. The first approach employs intrusive and non-intrusive load-monitoring techniques to estimate the energy use of individual occupants. The second approach models diverse characteristics related to occupants’ energy-consuming behaviors in order to assess and predict such characteristics’ impacts on the energy performance of commercial buildings; this approach mostly utilizes agent-based modeling techniques to simulate actions and interactions between occupants and their built environment. The third approach employs occupancy-focused interventions to change occupants’ energy-use characteristics. Based on the detailed review of each approach, critical issues and current gaps in knowledge in the existing literature are discussed, and directions for future research opportunities in this field are provided.

  15. North House : developing intelligent building technology and user interface in energy independent domestic environments

    Energy Technology Data Exchange (ETDEWEB)

    Velikov, K. [Waterloo Univ., Cambridge, ON (Canada). School of Architecture; Bartram, L. [Simon Fraser Univ., Surrey, BC (Canada). School of Interactive Arts and Technology

    2009-07-01

    This paper reported on the construction of the North House, a prototype solar-powered dwelling developed by a Canadian team for the 2009 Solar Decathlon. The prototype aims to develop a strategy for solar powered residential design that addresses the issues of how to build and live in the demanding northern context, how to design buildings that are adaptive to climate extremes and how new technologies and alternative energies can be used to create a viable and sustainable architecture. The occupant-focused design is meant to empower the occupants with both knowledge and control so that they can make intelligent choices and transform their own habits to live more sustainably. The residential occupant needs to operate as both user and manager of a green dwelling, and therefore requires specific information as well as access to help the building work more efficiently. The domestic environment is different from a workplace environment and therefore requires a unique means of control, display and integration with user lifestyle. The Adaptive Living Interface System for North House is based on interactive technologies that help occupants to both control the systems of the house while providing feedback on the operation of the house. The objective is to support behavioural transformation for energy saving living patterns. Once the competition is over, the North House will be reinstalled in Canada to undergo a minimum of 2 years of post-occupancy evaluation (POE) and testing. Both quantitative and qualitative data will be collected on energy performance, user livability, comfort and user satisfaction. Results were be measured against performance simulation during the design phase and will be used to provide feedback on simulation software. 11 refs., 5 figs.

  16. Interface

    DEFF Research Database (Denmark)

    Computerens interface eller grænseflade har spredt sig overalt. Mobiltelefoner, spilkonsoller, pc'er og storskærme indeholder computere – men computere indbygges også i tøj og andre hverdagslige genstande, så vi konstant har adgang til digitale data. Interface retter fokus mod, hvordan den digita...

  17. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-09-01

    This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  18. Establishing a Commercial Buildings Energy Data Framework for India: A Comprehensive Look at Data Collection Approaches, Use Cases and Institutions

    Energy Technology Data Exchange (ETDEWEB)

    Iyer, Maithili [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kumar, Satish [Synurja, LLC, Vienna, VA (United States); Mathew, Sangeeta [Synurja, LLC, Vienna, VA (United States); Stratton, Hannah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mathew, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singh, Mohini [Synurja, LLC, Vienna, VA (United States)

    2016-10-01

    Enhancing energy efficiency of the commercial building stock is an important aspect of any national energy policy. Understanding how buildings use energy is critical to formulating any new policy that may impact energy use, underscoring the importance of credible data. Data enables informed decision making and good quality data is essential for policy makers to prioritize energy saving strategies and track implementation. Given the uniqueness of the buildings sector and challenges to collecting relevant energy data, this study characterizes various elements involved in pertinent data collection and management, with the specific focus on well-defined data requirements, appropriate methodologies and processes, feasible data collection mechanisms, and approaches to institutionalizing the collection process. This report starts with a comprehensive review of available examples of energy data collection frameworks for buildings across different countries. The review covers the U.S. experience in the commercial buildings sector, the European experience in the buildings sector and other data collection initiatives in Singapore and China to capture the more systematic efforts in Asia in the commercial sector. To provide context, the review includes a summary and status of disparate efforts in India to collect and use commercial building energy data. Using this review as a key input, the study developed a data collection framework for India with specific consideration to relevant use cases. Continuing with the framework for data collection, this study outlines the key performance indicators applicable to the use cases and their collection feasibility, as well as immediate priorities of the participating stakeholders. It also discusses potential considerations for data collection and the possible approaches for survey design. With the specific purpose of laying out the possible ways to structure and organize data collection institutionally, the study collates existing

  19. Estimating energy impacts of residential and commercial building development. A manual for the Pacific Northwest and Alaska

    Energy Technology Data Exchange (ETDEWEB)

    1979-02-22

    This energy-impact manual presents information on energy implications of new building design and operation, providing a reasonably accurate means of assessing the total energy impact of new construction in the commercial and residential sectors. While developed specifically for the states of Alaska, Idaho, Oregon, and Washington, much of the data used are national averages; the procedures described are applicable to other regions of the nation, with appropriate adjustments for climatic differences. The manual is organized into three parts, each covering one aspect of the energy impacts of building development. Part I addresses the energy impact of erecting the building(s). This includes the energy cost of grading and excavating and other site preparation. It also takes into account the energy embodied in the fabrication of materials used in building construction, as well as the energy cost of transporting materials to the site and assembling them. Part II focuses on the end use of energy during normal building operation, i.e., the energy consumed for space heating, cooling, lighting, water heating, etc. A simplified calculation sequence is provided which allows the user to estimate the consumption of most combinations of building orientation, characteristics, and operating conditions. Part III examines the relationship of land use to energy consumption, principally the transportation energy impact of various land-development patterns, the embodied energy impacts of infrastructure requirements, and the impacts of various orientation and siting schemes. (MCW)

  20. Commercial building to low energy standards. Crucial decisions at building shell; Geschaeftsbau nach Passivhaus-Standard. Entscheidende Weichenstellungen beim Rohbau

    Energy Technology Data Exchange (ETDEWEB)

    Brenckle, R.

    2007-07-01

    This article describes the Customer Care Centre of the IWB utility in Basel, Switzerland, which was built to the Minergie-P extremely low energy consumption standard. In particular, the importance of crucial decisions made before the start of the construction of the building's shell is stressed. The optimal co-ordination of statics, insulation and permeability is discussed, as are aspects concerning the positioning of windows, waste-heat recovery and air-conditioning. The project and its background are discussed. The heating and ventilation concept, heat gains and losses and the associated ideas used in the building are looked at in detail.

  1. Interface

    DEFF Research Database (Denmark)

    Computerens interface eller grænseflade har spredt sig overalt. Mobiltelefoner, spilkonsoller, pc'er og storskærme indeholder computere – men computere indbygges også i tøj og andre hverdagslige genstande, så vi konstant har adgang til digitale data. Interface retter fokus mod, hvordan den digitale...... kunst og kultur skabes, spredes og opleves igennem interfaces. Forfatterne undersøger og diskuterer interfacets æstetik, ideologi og kultur – og analyserer aktuel interfacekunst på tværs af musik, kunst, litteratur og film. Bogen belyser interfacets oprindelse i den kolde krigs laboratorier og dets...

  2. Development of a methodology for defining whole-building energy design targets for commercial buildings: Phase 2, Development concept stage report

    Energy Technology Data Exchange (ETDEWEB)

    Jones, J.W. (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA (USA)); Deringer, J.J. (American Inst. of Architects, Washington, DC (USA)); McKay, H.N. (Illuminating Engineering Society of North America, New York, NY (USA))

    1990-09-01

    Since 1985, the Pacific Northwest Laboratory (PNL) has managed the Whole-Building Energy Design Targets project for the US Department of Energy (DOE) Office of Building Technologies (formerly the Office of Buildings and Community Systems). The primary focus of the Targets project is to develop a flexible methodology for buildings industry use in setting energy performance guidelines for commercial buildings and for determining compliance with those guidelines. The project is being conducted as a two-phase effort. In Phase 1, Planning, the project team determined the research that was necessary for developing the Targets methodology. In the concept stage of Phase 2, Development, the team sought to define the technical and software development concepts upon which the overall Targets methodology will be based. The concept stage work is documented in four volumes, of which this summary volume is the first. The three other volumes are Volume 2: Technical Concept Development Task Reports, Volume 3: Workshop Summaries, and Volume 4: Software Concept Development Task Reports. 8 refs., 14 figs.

  3. Final Scientific Technical Report: INTEGRATED PREDICTIVE DEMAND RESPONSE CONTROLLER FOR COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, Mike

    2013-10-14

    This project provides algorithms to perform demand response using the thermal mass of a building. Using the thermal mass of the building is an attractive method for performing demand response because there is no need for capital expenditure. The algorithms rely on the thermal capacitance inherent in the building?s construction materials. A near-optimal ?day ahead? predictive approach is developed that is meant to keep the building?s electrical demand constant during the high cost periods. This type of approach is appropriate for both time-of-use and critical peak pricing utility rate structures. The approach uses the past days data in order to determine the best temperature setpoints for the building during the high price periods on the next day. A second ?model predictive approach? (MPC) uses a thermal model of the building to determine the best temperature for the next sample period. The approach uses constant feedback from the building and is capable of appropriately handling real time pricing. Both approaches are capable of using weather forecasts to improve performance.

  4. Analysis of Plug Load Capacities and Power Requirements in Commercial Buildings: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Sheppy, M.; Torcellini, P.; Gentile-Polese, L.

    2014-08-01

    Plug and process load power requirements are frequently overestimated because designers often use estimates based on 'nameplate' data, or design assumptions are high because information is not available. This generally results in oversized heating, ventilation, and air-conditioning systems; increased initial construction costs; and increased energy use caused by inefficiencies at low, part-load operation. Rightsizing of chillers in two buildings reduced whole-building energy use by 3%-4%. If an integrated design approach could enable 3% whole-building energy savings in all U.S. office buildings stock, it could save 34 TBtu of site energy per year.

  5. Energy efficiency and existing buildings. Energetical sanitation of residential buildings and commercial buildings; Energieeffizienz + Bestand. Energetische Sanierung von Wohn- und Nutzgebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Sick, F. (ed.) [Fachhochschule fuer Technik und Wirtschaft, Berlin (Germany)

    2007-07-01

    Within the first International User Forum - energy efficiency and existing buildings - of the Ostbayerische Technologie Transfer Institut e.V. (Regensburg, Federal Republic of Germany) at 15th and 16th February, 2007, in Bad Staffelstein (Federal Republic of Germany) the following lectures were held: (1) Potentials and markets of the energetic building refurbishment (Andreas Wagner); (2) Implementation of the EU building regulation in the Federal Republic of Germany in DIN V 18599; energy pass, EnEV 2006, results of the legislation (Fred Weigl); (3) Financing and economic efficiency of measures of energetic building refurbishment (Frank Pinsler); (4) Saving energy in building pools - Experiences from 1,000 buildings of the capital Munich (Matthias Domke); (5) Solar housing estates - Energy efficiency and utilization of renewable energy in North-Rhine Westphalia (Hartmut Murschall); (6) Integrated planning - from single components to total project (Boris Mahler); (7) Dynamic simulation - Introduction into methods of calculation for non-residential buildings (Andreas Gerber); (8) Approaches of calculation according to DIN 18599 and evaluation (Helmut E. Feustel); (9) An overview on software tools for an energetic building refurbishment (Anja Rosenbach); (10) Incorporation of regenerative energies in building refurbishment - The 'Solar energy centre' in multi-storey residential buildings (Bernhard Jurisch); (11) Home-automation - networking of plants saves energy and operating costs (Manfred Riedel); (12) Cogeneration-cold coupling (Wolfgang Schoelkopf); (13) International significance of the energetic building refurbishment (Robert Hastings); (14) Energetic reconstruction of plate buildings in Germany, Eastern Austria, Russia and People's Republic of China (Alfred Kerschberger); (15) eea - European Energy Award - The European standard for energy efficient communities (Armand Duetz, Ilga Schwidder); (16) Best practice examples from Austria (Ernst

  6. Interface investigations of a commercial lithium ion battery graphite anode material by sputter depth profile X-ray photoelectron spectroscopy.

    Science.gov (United States)

    Niehoff, Philip; Passerini, Stefano; Winter, Martin

    2013-05-14

    Here we provide a detailed X-ray photoelectron spectroscopy (XPS) study of the electrode/electrolyte interface of a graphite anode from commercial NMC/graphite cells by intense sputter depth profiling using a polyatomic ion gun. The uniqueness of this method lies in the approach using 13-step sputter depth profiling (SDP) to obtain a detailed model of the film structure, which forms at the electrode/electrolyte interface often noted as the solid electrolyte interphase (SEI). In addition to the 13-step SDP, several reference experiments of the untreated anode before formation with and without electrolyte were carried out to support the interpretation. Within this work, it is shown that through charging effects during X-ray beam exposure chemical components cannot be determined by the binding energy (BE) values only, and in addition, that quantification by sputter rates is complicated for composite electrodes. A rough estimation of the SEI thickness was carried out by using the LiF and graphite signals as internal references.

  7. Scale Matters: An Action Plan for Realizing Sector-Wide"Zero-Energy" Performance Goals in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Selkowitz, Stephen; Selkowitz, Stephen; Granderson, Jessica; Haves, Philip; Mathew, Paul; Harris, Jeff

    2008-06-16

    It is widely accepted that if the United States is to reduce greenhouse gas emissions it must aggressively address energy end use in the building sector. While there have been some notable but modest successes with mandatory and voluntary programs, there have also been puzzling failures to achieve expected savings. Collectively, these programs have not yet reached the majority of the building stock, nor have they yet routinely produced very large savings in individual buildings. Several trends that have the potential to change this are noteworthy: (1) the growing market interest in 'green buildings' and 'sustainable design', (2) the major professional societies (e.g. AIA, ASHRAE) have more aggressively adopted significant improvements in energy efficiency as strategic goals, e.g. targeting 'zero energy', carbon-neutral buildings by 2030. While this vision is widely accepted as desirable, unless there are significant changes to the way buildings are routinely designed, delivered and operated, zero energy buildings will remain a niche phenomenon rather than a sector-wide reality. Toward that end, a public/private coalition including the Alliance to Save Energy, LBNL, AIA, ASHRAE, USGBC and the World Business Council for Sustainable Development (WBCSD) are developing an 'action plan' for moving the U.S. commercial building sector towards zero energy performance. It addresses regional action in a national framework; integrated deployment, demonstration and R&D threads; and would focus on measurable, visible performance indicators. This paper outlines this action plan, focusing on the challenge, the key themes, and the strategies and actions leading to substantial reductions in GHG emissions by 2030.

  8. Simulation-based coefficients for adjusting climate impact on energy consumption of commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na; Makhmalbaf, Atefe; Srivastava, Viraj; Hathaway, John E.

    2016-11-23

    This paper presents a new technique for and the results of normalizing building energy consumption to enable a fair comparison among various types of buildings located near different weather stations across the U.S. The method was developed for the U.S. Building Energy Asset Score, a whole-building energy efficiency rating system focusing on building envelope, mechanical systems, and lighting systems. The Asset Score is calculated based on simulated energy use under standard operating conditions. Existing weather normalization methods such as those based on heating and cooling degrees days are not robust enough to adjust all climatic factors such as humidity and solar radiation. In this work, over 1000 sets of climate coefficients were developed to separately adjust building heating, cooling, and fan energy use at each weather station in the United States. This paper also presents a robust, standardized weather station mapping based on climate similarity rather than choosing the closest weather station. This proposed simulated-based climate adjustment was validated through testing on several hundreds of thousands of modeled buildings. Results indicated the developed climate coefficients can isolate and adjust for the impacts of local climate for asset rating.

  9. Demand Shifting with Thermal Mass in Large Commercial Buildings in a California Hot Climate Zone

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Peng; Yin, Rongxin; Brown, Carrie; Kim, DongEun

    2009-06-01

    The potential for using building thermal mass for load shifting and peak energy demand reduction has been demonstrated in a number of simulation, laboratory, and field studies. Previous Lawrence Berkeley National Laboratory research has demonstrated that the approach is very effective in cool and moderately warm climate conditions (California Climate Zones 2-4). However, this method had not been tested in hotter climate zones. This project studied the potential of pre-cooling the building early in the morning and increasing temperature setpoints during peak hours to reduce cooling-related demand in two typical office buildings in hotter California climates ? one in Visalia (CEC Climate Zone 13) and the other in San Bernardino (CEC Climate Zone 10). The conclusion of the work to date is that pre-cooling in hotter climates has similar potential to that seen previously in cool and moderate climates. All other factors being equal, results to date indicate that pre-cooling increases the depth (kW) and duration (kWh) of the possible demand shed of a given building. The effectiveness of night pre-cooling in typical office building under hot weather conditions is very limited. However, night pre-cooling is helpful for office buildings with an undersized HVAC system. Further work is required to duplicate the tests in other typical buildings and in other hot climate zones and prove that pre-cooling is truly effective.

  10. The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Cardoso, Goncalo; Lipman, Tim; Megel, Olivier; Ganguly, Srirupa; Siddiqui, Afzal; Lai, Judy

    2009-11-16

    The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed

  11. The Influence of a CO2 Pricing Scheme on Distributed Energy Resources in California's Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Lai, Judy; Cardoso, Goncalo; Megel, Olivier; Siddiqui, Afzal

    2010-06-01

    The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial-sector distributed energy resources (DER) with combined heat and power (CHP) in greenhouse gas emissions (GHG) reductions. Historically, relatively little attention has been paid to the potential of medium-sized commercial buildings with peak electric loads ranging from 100 kW to 5 MW. In our research, we examine how these medium-sized commercial buildings might implement DER and CHP. The buildings are able to adopt and operate various technologies, e.g., photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, batteries and thermal storage systems. We apply the Distributed Energy Resources Customer Adoption Model (DER-CAM), which is a mixed-integer linear program (MILP) that minimizes a site?s annual energy costs and/or CO2 emissions. Using 138 representative mid-sized commercial sites in California, existing tariffs of major utilities, and expected performance data of available technologies in 2020, we find the GHG reduction potential for these buildings. We compare different policy instruments, e.g., a CO2 pricing scheme or a feed-in tariff (FiT), and show their contributions to the California Air Resources Board (CARB) goals of additional 4 GW CHP capacities and 6.7 Mt/a GHG reduction in California by 2020. By applying different price levels for CO2, we find that there is competition between fuel cells and PV/solar thermal. It is found that the PV/solar thermal adoption increases rapidly, but shows a saturation at high CO2 prices, partly due to limited space for PV and solar thermal. Additionally, we find that large office buildings are good hosts for CHP in general. However, most interesting is the fact that fossil-based CHP adoption also increases with increasing CO2 prices. We will show service territory specific results since the

  12. The analysis of energy consumption and greenhouse gas emissions of a large-scale commercial building in Shanghai, China

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2016-02-01

    Full Text Available Reasonable test, diagnosis, and analysis are meaningful for building energy efficiency retrofit and management. Energy consumption and greenhouse gas emission of a large-scale commercial building are described in this article. Basic information about energy consumption equipment is included in the investigation. Further diagnoses about the operational state of air-conditioning water systems, and ducted systems were implemented. Energy consumption decreased 200 kWh/m2 per year from 2007 to 2009 after energy-saving reconstruction in 2006. Next, a carbon audit was carried out; this comprised CO2 emission statistics associated with the energy use and categorization and structural analysis (categorization refers to energy categorization and structural analysis means the composition and its proportion relationship of all kinds of primary energy and secondary energy in energy production or consumption. Greenhouse gas emissions could be less than 150 kg/m2 per year from 2007 to 2009. An analysis of the correlation between CO2 emissions, building gross domestic product, and energy efficiency is also presented. This article makes an analysis on the energy utilization and energy-saving reconstruction of a public commercial building in Shanghai and then makes an analysis of carbon audit about greenhouse gas emissions related to energy utilization (it analyzes the status of building’s energy utilization and greenhouse gas emissions, to have a more comprehensive understanding on the internal relationship between energy consumption and its greenhouse gas emissions and provide researchful reference data for the development with reduction strategies of greenhouse gas emission in future building.

  13. Moisture Control Guidance for Commercial and Public Buildings (EPA 402-F-13053)

    Science.gov (United States)

    This document provides guidance to designers, construction mangers, and building operation/maintenance managers to improve IEQ and reduce risks of encountering IEQ problems due to insufficient moisture control. EPA will be producing a document entitled "Moisture Control Guida...

  14. An open-source automated continuous condition-based maintenance platform for commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas; Gowri, Krishnan; Hernandez, George

    2016-09-09

    This paper describes one such reference process that can be deployed to provide continuous automated conditioned-based maintenance management for buildings that have BIM, a building automation system (BAS) and a computerized maintenance management software (CMMS) systems. The process can be deployed using an open source transactional network platform, VOLTTRON™, designed for distributed sensing and controls and supports both energy efficiency and grid services.

  15. Life cycle cost analysis of commercial buildings with energy efficient approach

    OpenAIRE

    Nilima N. Kale; Deepa Joshi; Radhika Menon

    2016-01-01

    In any construction project, cost effectiveness plays a crucial role. The Life Cycle Cost (LCC) analysis provides a method of determining entire cost of a structure over its expected life along with operational and maintenance cost. LCC can be improved by adopting alternative modern techniques without much alteration in the building. LCC effectiveness can be calculated at various stages of entire span of the building. Moreover this provides decision makers with the financial information neces...

  16. A Retrospective Analysis of Commercial Building Energy Codes: 1990 – 2008

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, David B.; McDonald, Sean C.; Halverson, Mark A.

    2010-10-01

    Building Energy Codes Program's efforts are designed to result in increased stringency in national model energy codes, more rapid and broader adoption by states and localities of updated codes, and increased compliance and enforcement. Report estimates the historical impact of Building Energy Codes Program in terms of energy savings achieved that are based upon various editions of ANSI/ASHRAE/IESNA Standard 90.1 (ASHRAE Standard 90.1).

  17. Demand Shifting With Thermal Mass in Large Commercial Buildings:Field Tests, Simulation and Audits

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Peng; Haves, Philip; Piette, Mary Ann; Zagreus, Leah

    2005-09-01

    The principle of pre-cooling and demand limiting is to pre-cool buildings at night or in the morning during off-peak hours, storing cooling in the building thermal mass and thereby reducing cooling loads and reducing or shedding related electrical demand during the peak periods. Cost savings are achieved by reducing on-peak energy and demand charges. The potential for utilizing building thermal mass for load shifting and peak demand reduction has been demonstrated in a number of simulation, laboratory, and field studies (Braun 1990, Ruud et al. 1990, Conniff 1991, Andresen and Brandemuehl 1992, Mahajan et al. 1993, Morris et al. 1994, Keeney and Braun 1997, Becker and Paciuk 2002, Xu et al. 2003). This technology appears to have significant potential for demand reduction if applied within an overall demand response program. The primary goal associated with this research is to develop information and tools necessary to assess the viability of and, where appropriate, implement demand response programs involving building thermal mass in buildings throughout California. The project involves evaluating the technology readiness, overall demand reduction potential, and customer acceptance for different classes of buildings. This information can be used along with estimates of the impact of the strategies on energy use to design appropriate incentives for customers.

  18. Building web service interfaces to geoscience data sets: EarthCube GeoWS project activities at the IRIS DMC

    Science.gov (United States)

    Trabant, C. M.; Ahern, T. K.; Stults, M.

    2015-12-01

    At the IRIS Data Management Center (DMC) we have been developing web service data access interfaces for our, primarily seismological, repositories for five years. These interfaces have become the primary access mechanisms for all data extraction from the DMC. For the last two years the DMC has been a principal participant in the GeoWS project, which aims to develop common web service interfaces for data access across hydrology, geodesy, seismology, marine geophysics, atmospheric and other geoscience disciplines. By extending our approach we have converged, along with other project members, on a web service interface and presentation design appropriate for geoscience and other data. The key principles of the approach include using a simple subset of RESTful concepts, common calling conventions whenever possible, a common tabular text data set convention, human-readable documentation and tools to help scientific end users learn how to use the interfaces. The common tabular text format, called GeoCSV, has been incorporated into the DMC's seismic station and event (earthquake) services. In addition to modifying our existing services, we have developed prototype GeoCSV web services for data sets managed by external (unfunded) collaborators. These prototype services include interfaces for data sets at NGDC/NCEI (water level tides and meteorological satellite measurements), INTERMAGNET repository and UTEP gravity and magnetic measurements. In progress are interfaces for WOVOdat (volcano observatory measurements), NEON (ecological observatory measurements) and more. An important goal of our work is to build interfaces usable by non-technologist end users. We find direct usability by researchers to be a major factor in cross-discipline data use, which itself is a key to solving complex research questions. In addition to data discovery and collection by end users, these interfaces provide a foundation upon which federated data access and brokering systems are already being

  19. Approach for Estimating Exposures and Incremental Health Effects from Lead Due to Renovation Repair and Painting Activities in Public and Commercial Buildings

    Science.gov (United States)

    Approach for Estimating Exposures and Incremental Health Effects from Lead Due to Renovation Repair and Painting Activities in Public and Commercial Buildings: links to documents at www.regulations.gov, links to PDFs related to Approach document

  20. Life cycle cost analysis of commercial buildings with energy efficient approach

    Directory of Open Access Journals (Sweden)

    Nilima N. Kale

    2016-09-01

    Full Text Available In any construction project, cost effectiveness plays a crucial role. The Life Cycle Cost (LCC analysis provides a method of determining entire cost of a structure over its expected life along with operational and maintenance cost. LCC can be improved by adopting alternative modern techniques without much alteration in the building. LCC effectiveness can be calculated at various stages of entire span of the building. Moreover this provides decision makers with the financial information necessary for maintaining, improving, and constructing facilities. Financial benefits associated with energy use can also be calculated using LCC analysis. In the present work, case study of two educational buildings has been considered. The LCC of these buildings has been calculated with existing condition and with proposed energy efficient approach (EEA using net present value method. A solar panel having minimum capacity as well as solar panel with desired capacity as per the requirements of the building has been suggested. The comparison of LCC of existing structure with proposed solar panel system shows that 4% of cost can be reduced in case of minimum capacity solar panel and 54% cost can be reduced for desired capacity solar panel system, along with other added advantages of solar energy.

  1. interfaces

    Directory of Open Access Journals (Sweden)

    Dipayan Sanyal

    2005-01-01

    macroscopic conservation equations with an order parameter which can account for the solid, liquid, and the mushy zones with the help of a phase function defined on the basis of the liquid fraction, the Gibbs relation, and the phase diagram with local approximations. Using the above formalism for alloy solidification, the width of the diffuse interface (mushy zone was computed rather accurately for iron-carbon and ammonium chloride-water binary alloys and validated against experimental data from literature.

  2. GRO/EGRET data analysis software: An integrated system of custom and commercial software using standard interfaces

    Science.gov (United States)

    Laubenthal, N. A.; Bertsch, D.; Lal, N.; Etienne, A.; Mcdonald, L.; Mattox, J.; Sreekumar, P.; Nolan, P.; Fierro, J.

    1992-01-01

    The Energetic Gamma Ray Telescope Experiment (EGRET) on the Compton Gamma Ray Observatory has been in orbit for more than a year and is being used to map the full sky for gamma rays in a wide energy range from 30 to 20,000 MeV. Already these measurements have resulted in a wide range of exciting new information on quasars, pulsars, galactic sources, and diffuse gamma ray emission. The central part of the analysis is done with sky maps that typically cover an 80 x 80 degree section of the sky for an exposure time of several days. Specific software developed for this program generates the counts, exposure, and intensity maps. The analysis is done on a network of UNIX based workstations and takes full advantage of a custom-built user interface called X-dialog. The maps that are generated are stored in the FITS format for a collection of energies. These, along with similar diffuse emission background maps generated from a model calculation, serve as input to a maximum likelihood program that produces maps of likelihood with optional contours that are used to evaluate regions for sources. Likelihood also evaluates the background corrected intensity at each location for each energy interval from which spectra can be generated. Being in a standard FITS format permits all of the maps to be easily accessed by the full complement of tools available in several commercial astronomical analysis systems. In the EGRET case, IDL is used to produce graphics plots in two and three dimensions and to quickly implement any special evaluation that might be desired. Other custom-built software, such as the spectral and pulsar analyses, take advantage of the XView toolkit for display and Postscript output for the color hard copy. This poster paper outlines the data flow and provides examples of the user interfaces and output products. It stresses the advantages that are derived from the integration of the specific instrument-unique software and powerful commercial tools for graphics and

  3. Design of a mobile laboratory for ventilation studies and indoor air pollution monitoring. [Residences and commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Berk, J.V.; Hollowell, C.D.; Lin, C.I.; Pepper, J.H.

    1978-04-01

    A mobile laboratory for research and development studies of ventilation requirements and energy utilization in residential and commercial buildings was designed and fabricated. The mobile laboratory contains sampling, calibrating, and monitoring systems to measure the concentration of CO, CO/sub 2/, NO, NO/sub 2/, NO/sub x/, O/sub 3/, and SO/sub 2/, and infiltration rates can be monitored continuously using a tracer gas system in which the tracer is injected into the room, mixed with room air, and monitored.

  4. Alliance for Sustainable Colorado Renovation Raises Its Energy Performance to New Heights, Commercial Building Energy Efficiency (Fact Sheet); Energy Efficiency & Renewable Energy (EERE)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-01

    The Alliance for Sustainable Colorado (The Alliance) is a nonprofit organization aiming to transform sustainability from vision to reality. Part of its mission is to change the operating paradigms of commercial building design to make them more sustainable. Toward that end The Alliance uses its headquarters, The Alliance Center at 1536 Wynkoop Street in Denver, as a living laboratory, conductingpilot studies of innovative commercial-building-design solutions for using and generating energy.

  5. Commercialization strategy for the Department of Energy's Solar Buildings Demonstration Program

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    Efforts reported include: conducting a survey of existing commercial demonstration projects, categorizing these projects, determining criteria for evaluating the feasibility of continuing/aborting demonstration projects, and applying the criteria and making recommendations for which projects to continue and abort. It is recommended to refurbish 114 of the projects examined and to abandon 41. (LEW)

  6. A passive cooling system of residential and commercial buildings in summer or hot season

    Science.gov (United States)

    Rahman, M. M.; Mashud, M.; Chu, C. M.; Misaran, M. S. bin; Sarker, M.; Kumaresen, S.

    2015-12-01

    The increasing number of high rise buildings may contribute to lack of natural ventilation in modern buildings. Generally, fans and air conditioning are used in the modern building for cooling and air ventilation. Most of the energy in tropical regions are consumed by heating, cooling and ventilation appliances. Therefore, solar power appliances for cooling, heating and ventilation will be a suitable option for saving energy from the household sector. A modified-structure building is designed and constructed with solar chimney to enhance ventilation rate that increases cooling performance and ensure thermal comfort. An evaporative cooler is introduced with a newly designed room to enhance the temperature reduction capacity. The room temperature is compared with a non-modified room as well as with ambient temperature. The results show that passive cooling system with evaporative cooler was able to reduce temperature by 5°C compared to the ambient temperature and about 2°C to 3°C below the reference room temperature.

  7. 75 FR 24848 - Lead; Renovation, Repair, and Painting Program for Public and Commercial Buildings

    Science.gov (United States)

    2010-05-06

    ...., lessors of non- residential buildings and dwellings, non-residential property managers. Facilities support... information claimed as CBI must be submitted for inclusion in the public docket. Information so marked will..., bluish metallic chemical element mined from rock and found in its natural state all over the world. Lead...

  8. A comprehensive approach to integrated envelope and lighting systems for new commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, E.S.; Selkowitz, S.E.; Rubinstein, F.M.; Klems, J.H.; Beltran, L.O.; DiBartolomeo, D.L. [Lawrence Berkeley Lab., CA (United States). Building Technologies Program

    1994-05-01

    The authors define a comprehensive approach to integrated envelope and lighting systems design as one that balances energy efficiency with an equal regard to the resultant environmental quality. By integrating envelope components (glazing, shading, and daylighting), lighting components (fixtures and controls) and building HVAC/energy management control systems, they create building systems that have the potential to achieve significant decreases in electricity consumption and peak demand while satisfying occupant physiological and psychological concerns. This paper presents results on the development, implementation, and demonstration of two specific integrated envelope and lighting systems: (1) a system emphasizing dynamic envelope components and responsive electric lighting systems, that offer the potential to achieve energy efficiency goals and a near optimum comfort environment throughout the year by adapting to meteorological conditions and occupant preferences in real time, and (2) perimeter daylighting systems that increase the depth of daylight penetration from sidelight windows and improves visual comfort with the use of a small inlet aperture. The energy performance of the systems was estimated using the DOE-2 building energy simulation program. Field tests with reduced scale models were conducted to determine daylighting and thermal performance in real time under actual weather conditions. Demonstrations of these integrated systems are being planned or are in progress in collaboration with utility programs to resolve real-world implementation issues under complex site, building, and cost constraints. Results indicate that integrated systems offer solutions that not only achieve significant peak demand reductions but also realize consistent energy savings with added occupant comfort and satisfaction.

  9. What a New Energy Efficiency Measure for Commercial Buildings Means to You

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.

    2016-12-19

    This article describes a new path for compliance with ASHRAE Standard 90.1-2016. The new approach will lead to increased flexibility for designers, multiple uses for the same building energy models, increased recognition of energy saving design strategies, and lower energy modeling costs.

  10. Building the System Interface Management Environment for the Development of Complex System

    Directory of Open Access Journals (Sweden)

    Sung Gyun Oh

    2015-07-01

    Full Text Available Advanced systems have common characteristics of complexity as the level of their demanded emergent capability and the resulting interfaces among their components increase. These characteristics make it difficult to manage the interfaces and the failure of the management can lead to the failure of development projects. This study proposes a model-based systems engineering approach to facilitate the interface management for an IPT environment. A demonstration of the proposed approach to the magnetic levitation railway development project is provided to identify and control interfaces.

  11. Costs and Operating Dynamics of Integrating Distributed Energy Resources in Commercial and Industrial Buildings with Electric Vehicle Charging

    Science.gov (United States)

    Flores, Robert Joseph

    Growing concerns over greenhouse gas and pollutant emissions have increased the pressure to shift energy conversion paradigms from current forms to more sustainable methods, such as through the use of distributed energy resources (DER) at industrial and commercial buildings. This dissertation is concerned with the optimal design and dispatch of a DER system installed at an industrial or commercial building. An optimization model that accurately captures typical utility costs and the physical constraints of a combined cooling, heating, and power (CCHP) system is designed to size and operate a DER system at a building. The optimization model is then used with cooperative game theory to evaluate the financial performance of a CCHP investment. The CCHP model is then modified to include energy storage, solar powered generators, alternative fuel sources, carbon emission limits, and building interactions with public and fleet PEVs. Then, a separate plugin electric vehicle (PEV) refueling model is developed to determine the cost to operate a public Level 3 fast charging station. The CCHP design and dispatch results show the size of the building load and consistency of the thermal loads are critical to positive financial performance. While using the CCHP system to produce cooling can provide savings, heat production drives positive financial performance. When designing the DER system to reduce carbon emissions, the use of renewable fuels can allow for a gas turbine system with heat recovery to reduce carbon emissions for a large university by 67%. Further reductions require large photovoltaic installations coupled with energy storage or the ability to export electricity back to the grid if costs are to remain relatively low. When considering Level 3 fast charging equipment, demand charges at low PEV travel levels are sufficiently high to discourage adoption. Integration of the equipment can reduce demand charge costs only if the building maximum demand does not coincide

  12. Optimization of a hybrid electric power system design for large commercial buildings: An application design guide

    Science.gov (United States)

    Lee, Keun

    Renewable energy in different forms has been used in various applications for survival since the beginning of human existence. However, there is a new dire need to reevaluate and recalibrate the overall energy issue both nationally and globally. This includes, but is not limited to, the finite availability of fossil fuel, energy sustainability with an increasing demand, escalating energy costs, environmental impact such as global warming and green-house gases, to name a few. This dissertation is primarily focused and related to the production and usage of electricity from non-hydro renewable sources. Among non-hydro renewable energy sources, electricity generation from wind and solar energy are the fastest-growing technologies in the United States and in the world. However, due to the intermittent nature of such renewable sources, energy storage devices are required to maintain proper operation of the grid system and in order to increase reliability. A hybrid system, as the name suggests, is a combination of different forms of non-renewable and renewable energy generation, with or without storage devices. Hybrid systems, when applied properly, are able to improve reliability and enhance stability, reduce emissions and noise pollution, provide continuous power, increase operation life, reduce cost, and efficiently use all available energy. In the United States (U.S.), buildings consume approximately 40% of the total primary energy and 74% of the total electricity. Therefore, reduction of energy consumption and improved energy efficiency in U.S. buildings will play a vital role in the overall energy picture. Electrical energy usage for any such building varies widely depending on age (construction technique), electricity and natural gas usage, appearance, location and climate. In this research, a hybrid system including non-renewable and renewable energy generation with storage devices specifically for building applications, is studied in detail. This research deals

  13. Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Betts, Daniel [Be Power Tech, Deerfield Beach, FL (United States); Ally, Moonis Raza [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mudiraj, Shyam [Be Power Tech, Deerfield Beach, FL (United States); Tilghman, Matthew [Be Power Tech, Deerfield Beach, FL (United States); Graham, Matthew [Be Power Tech, Deerfield Beach, FL (United States)

    2017-04-30

    Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

  14. Construction execution and techology optimization – commercial and business building case study

    OpenAIRE

    Kumalić, Emir

    2010-01-01

    The key element for successful construction site is time-schedule, which allows us time organizing of construction site itself and reliable evaluation of construction course. In my work I discuss organization of construction site and construction technology, with emphasis on optimization of time-schedule. I applied it on the case of commercial-business object, which will be built in Ljubljana. After introduction, I have described this object further I described work technology and preparatory...

  15. Performance of a selective-surface trombe wall in a small commercial building

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, R.; Sokol, F.

    1981-03-01

    The design and construction of a 100% passive solar building utilizing a clerestory and a trombe wall are described. The use of three selectively absorptive and emissive coverings on the trombe wall outer surface are investigated. One of the coverings and its laminating adhesive are tested for degradation after a year of exposure under normal operating conditions. Ambient temperature, room air temperature, trombe wall interior and exterior surface temperatures, and solar radiation are measured.

  16. Methodology for Analyzing the Technical Potential for Energy Performance in the U.S. Commercial Buildings Sector with Detailed Energy Modeling: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.; Crawley, D.

    2006-11-01

    This paper summarizes a methodology for developing quantitative answers to the question, ''How low can energy use go within the commercial buildings sector''? The basic process is to take each building in the 1999 CBECS public use data files and create a baseline building energy model for it as if it were being built new in 2005 with code-minimum energy performance.

  17. Safety assessment of A92 reactor building for large commercial aircraft crash

    Energy Technology Data Exchange (ETDEWEB)

    Kostov, M., E-mail: marin.kostov@riskeng.bg [Risk Engineering Ltd., Sofia (Bulgaria); Henkel, F.O. [Woelfel Beratende Ingenieure, Hoechberg (Germany); Andonov, A. [Risk Engineering Ltd., Sofia (Bulgaria)

    2014-04-01

    The current paper presents key elements of the comprehensive analyses of the effects due to a large aircraft collision with the reactor building of Belene NPP in Bulgaria. The reactor building is a VVER A92; it belongs to the third+ generation and includes structural measures for protection against an aircraft impact as standard design. The A92 reactor building implements a double shell concept and is composed of thick RC external walls and an external shell which surrounds an internal pre-stressed containment and the internal walls of the auxiliary building. The malevolent large aircraft impact is considered as a beyond design base accident (Design Extended Conditions, DEC). The main issues under consideration are the structural integrity, the equipment safety due to the induced vibrations, and the fire safety of the entire installation. Many impact scenarios are analyzed varying both impact locations and loading intensity. A large number of non-linear dynamic analyses are used for assessment of the structural response and capacity, including different type of structural models, different finite element codes, and different material laws. The corresponding impact loadings are represented by load time functions calculated according to three different approaches, i.e. loading determined by Riera's method (Riera, 1968), load time function calculated by finite element analysis (Henkel and Klein, 2007), and coupled dynamic analysis with dynamic interaction between target and projectile. Based on the numerical results and engineering assessments the capacity of the A92 reactor building to resist a malevolent impact of a large aircraft is evaluated. Significant efforts are spent on safety assessment of equipment by using an evaluation procedure based on damage indicating parameters. As a result of these analyses several design modifications of structure elements are performed. There are changes of the layout of reinforcement, special arrangements and spatial

  18. Chemical and electronic interface structure of spray pyrolysis deposited undoped and Al-doped ZnO thin films on a commercial Cz-Si solar cell substrate

    Energy Technology Data Exchange (ETDEWEB)

    Gabas, M.; Ramos-Barrado, J.R. [Dpto. de Fisica Aplicada I, Lab. de Materiales y Superficies, Universidad de Malaga 29071 Malaga (Spain); Barrett, N.T. [CEA DSM/IRAMIS/SPCSI, CEA Saclay, 91191 Gif sur Yvette (France); Gota, S. [Laboratoire Leon Brillouin, UMR 012 CEA-CNRS CEA Saclay, 91191 Gif sur Yvette (France); Rojas, T.C. [Instituto de Ciencia de Materiales de Sevilla, CSIC, Americo Vespucio 49, 41092 Sevilla (Spain); Lopez-Escalante, M.C. [Isofoton S.A., Parque Tecnologico de Andalucia, Severo Ochoa, 50, 29590 Malaga (Spain)

    2009-08-15

    We have studied differences in the interface between undoped and Al-doped ZnO thin films deposited on commercial Si solar cell substrates. The undoped ZnO film is significantly thicker than the Al-doped film for the same deposition time. An extended silicate-like interface is present in both samples. Transmission electron microscopy (TEM) and photoelectron spectroscopy (PES) probe the presence of a zinc silicate and several Si oxides in both cases. Although Al doping improves the conductivity of ZnO, we present evidence for Al segregation at the interface during deposition on the Si substrate and suggest the presence of considerable fixed charge near the oxidized Si interface layer. The induced distortion in the valence band, compared to that of undoped ZnO, could be responsible for considerable reduction in the solar cell performance. (author)

  19. An improved assessment model of variable frequency-driven direct expansion air-conditioning system in commercial buildings for Taiwan green building rating system

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kuan-Hsiung [Department of Mechanical and Electro-mechanical Engineering, National Sun Yet-Sen University, 70 Lien-hai Rd., Kaohsiung 804 (China); Hwang, Ruey-Lung [Department of Safety and Health of Occupant, China Medical University, 91 Huseh-Shin Rd, Taichung, 404 (China)

    2007-10-15

    Because of the superior performance of the multi-unit variable frequency-driven (VFD) direct expansion (DX) air-conditioning system, installing this kind of system in rental commercial buildings, dwelling houses, and schools is becoming more and more popular in Taiwan. Even though the features and characteristics of the multi-unit VFD DX system are different from those of the central system, it is still assessed by the conventional method used for evaluating the efficiency of all air-conditioning systems, which is designed mainly for central systems. This article explains the problems that occur when the current assessment method is applied to the multi-unit VFD DX system. An alternative assessment method is proposed. (author)

  20. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  1. How to Estimate Demand Charge Savings from PV on Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Bird, Lori A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-28

    Rooftop photovoltaic (PV) systems are compensated through retail electricity tariffs - and for commercial and industrial customers, these are typically comprised of three components: a fixed monthly charge, energy charges, and demand charges. Of these, PV's ability to reduce demand charges has traditionally been the most difficult to estimate. In this fact sheet we explain the basics of demand charges, and provide a new method that a potential customer or PV developer can use to estimate a range of potential demand charge savings for a proposed PV system. These savings can then be added to other project cash flows, in assessing the project's financial performance.

  2. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Patrick O' Neill

    2009-06-30

    This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests

  3. Flat conductor cable commercialization project

    Science.gov (United States)

    Hogarth, P.; Wadsworth, E.

    1977-01-01

    An undercarpet flat conductor cable and a baseboard flat conductor cable system were studied for commercialization. The undercarpet system is designed for use in office and commercial buildings. It employs a flat power cable, protected by a grounded metal shield, that terminates in receptacles mounted on the floor. It is designed to interface with a flat conductor cable telephone system. The baseboard system consists of a flat power cable mounted in a plastic raceway; both the raceway and the receptacles are mounted on the surface of the baseboard. It is designed primarily for use in residential buildings, particularly for renovation and concrete and masonry construction.

  4. Prediction of Indoor Air Exposure from Outdoor Air Quality Using an Artificial Neural Network Model for Inner City Commercial Buildings

    Directory of Open Access Journals (Sweden)

    Avril Challoner

    2015-12-01

    Full Text Available NO2 and particulate matter are the air pollutants of most concern in Ireland, with possible links to the higher respiratory and cardiovascular mortality and morbidity rates found in the country compared to the rest of Europe. Currently, air quality limits in Europe only cover outdoor environments yet the quality of indoor air is an essential determinant of a person’s well-being, especially since the average person spends more than 90% of their time indoors. The modelling conducted in this research aims to provide a framework for epidemiological studies by the use of publically available data from fixed outdoor monitoring stations to predict indoor air quality more accurately. Predictions are made using two modelling techniques, the Personal-exposure Activity Location Model (PALM, to predict outdoor air quality at a particular building, and Artificial Neural Networks, to model the indoor/outdoor relationship of the building. This joint approach has been used to predict indoor air concentrations for three inner city commercial buildings in Dublin, where parallel indoor and outdoor diurnal monitoring had been carried out on site. This modelling methodology has been shown to provide reasonable predictions of average NO2 indoor air quality compared to the monitored data, but did not perform well in the prediction of indoor PM2.5 concentrations. Hence, this approach could be used to determine NO2 exposures more rigorously of those who work and/or live in the city centre, which can then be linked to potential health impacts.

  5. Baseline indoor air quality measurements collected from 136 metropolitan New York region commercial office buildings between 1997-1999.

    Science.gov (United States)

    Springston, John P; Esposito, William A; Cleversey, Keith W

    2002-01-01

    Between January 1997 and December 1999, 648 surveys were performed in 136 commercial office buildings in the metropolitan New York region as part of an ongoing proactive indoor environmental quality (IEQ) program. Sampling was performed on a spot basis in "nonproblem" buildings, during normal business hours, either quarterly or semiannually. Carbon dioxide (CO2), carbon monoxide (CO), and total volatile organic compounds (TVOCs) were among the various physical and gaseous parameters sampled for. More than 15,000 data points were collected, and the results were analyzed to determine the mean, median, mode, and standard deviation for each of those parameters. The data was then compared to various standards and/or guidelines applicable to the indoor environment. The results indicated that 98% of the CO2 readings were below 1000 ppm, and 99.9% of the CO readings were below 10 ppm. However, for TVOCs, nearly 88% of the readings exceeded the proposed European guideline value of 0.3 mg/m3. Ultimately, these results can be used to compare both baseline and periodic readings collected in future studies, and to help determine if potential problems exist within a building.

  6. Fire protection design of commercial and residential building%浅议商住楼的消防设计

    Institute of Scientific and Technical Information of China (English)

    张苏文

    2014-01-01

    With the development of the city, commercial buildings appear in large numbers, but the specification of current fire technical on the definition, building classification is not clear, some places are not reasonable. Architectural design personnel, fire engineering inspection personnel, fire supervision and inspection personnel of this understanding is not uniform, different points of view, objectively affect the development of fire supervision. In this paper, the definition, classification, building fire design requirements are analyzed, to put forward the reasonable suggestions for improvement.%随着城市化的发展,商住楼大量出现,但现行消防技术规范对其定义、建筑分类的规定不清晰,有些地方也不合理。建筑设计人员、消防工程审验人员、消防监督检查人员对此认识不统一、观点分歧,客观上影响了消防监督工作的开展。本文对其定义、建筑分类、消防设计要求等进行了分析,提出了合理化改进建议。

  7. Are we there yet? Evaluating commercial grade brain-computer interface for control of computer applications by individuals with cerebral palsy.

    Science.gov (United States)

    Taherian, Sarvnaz; Selitskiy, Dmitry; Pau, James; Claire Davies, T

    2017-02-01

    Using a commercial electroencephalography (EEG)-based brain-computer interface (BCI), the training and testing protocol for six individuals with spastic quadriplegic cerebral palsy (GMFCS and MACS IV and V) was evaluated. A customised, gamified training paradigm was employed. Over three weeks, the participants spent two sessions exploring the system, and up to six sessions playing the game which focussed on EEG feedback of left and right arm motor imagery. The participants showed variable inconclusive results in the ability to produce two distinct EEG patterns. Participant performance was influenced by physical illness, motivation, fatigue and concentration. The results from this case study highlight the infancy of BCIs as a form of assistive technology for people with cerebral palsy. Existing commercial BCIs are not designed according to the needs of end-users. Implications for Rehabilitation Mood, fatigue, physical illness and motivation influence the usability of a brain-computer interface. Commercial brain-computer interfaces are not designed for practical assistive technology use for people with cerebral palsy. Practical brain-computer interface assistive technologies may need to be flexible to suit individual needs.

  8. Electrochromic windows for commercial buildings: Monitored results from a full-scale testbed

    OpenAIRE

    Eleanor S. Lee; DiBartolomeo, Dennis L.; Selkowitz, Stephen E.

    2000-01-01

    Electrochromic glazings promise to be the next major advance in energy-efficient window technology, helping to transform windows and skylights from an energy liability to an energy source for the nation's building stock. Monitored results from a full-scale demonstration of large-area electrochromic windows are given. The test consisted of two side-by-side, 3.7x4.6-m, office-like rooms. In each room, five 62x173-cm lower electrochromic windows and five 62x43-cm upper electrochromic windo...

  9. Application of DOE-2 in the predesign phase of commercial-building design

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, J.L.; Hunn, B.D.

    1982-01-01

    This paper presents the results of a study in applying a high-level, computer-dynamic tool, DOE-2, to the predesign process for a standard test office building. This study was part of a larger study wherein five analysis tools, ranging from manual to computer-dynamic methods, were used to provide predesign energy information. The purpose was to test whether computer-dynamic tools, such as DOE-2 and BLAST, can readily provide the necessary predesign information in a usable visual format and without excessive cost.

  10. Passive solar commercial buildings: design assistance and demonstration program. Phase 1. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-01-26

    The final design of the Mount Airy Public Library is given. Incremental passive design costs are discussed. Performance and economic analyses are made and the results reported. The design process is thoroughly documented. Considerations discussed are: (1) building energy needs; (2) site energy potentials, (3) matching energy needs with site energy potentials, (4) design indicators for best strategies and concepts, (5) schematic design alternatives, (6) performance testing of the alternatives, (7) design selection, and (8) design development. Weather data and Duke Power electric rates are included. (LEW)

  11. Passive solar commercial buildings: design assistance and demonstration program. Phase 1. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-01-26

    The final design of the Mount Airy Public Library is given. Incremental passive design costs are discussed. Performance and economic analyses are made and the results reported. The design process is thoroughly documented. Considerations discussed are: (1) building energy needs; (2) site energy potentials, (3) matching energy needs with site energy potentials, (4) design indicators for best strategies and concepts, (5) schematic design alternatives, (6) performance testing of the alternatives, (7) design selection, and (8) design development. Weather data and Duke Power electric rates are included. (LEW)

  12. Using Models to Provide Predicted Ranges for Building-Human Interfaces: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Long, N.; Scheib, J.; Pless, S.; Schott, M.

    2013-09-01

    Most building energy consumption dashboards provide only a snapshot of building performance; whereas some provide more detailed historic data with which to compare current usage. This paper will discuss the Building Agent(tm) platform, which has been developed and deployed in a campus setting at the National Renewable Energy Laboratory as part of an effort to maintain the aggressive energyperformance achieved in newly constructed office buildings and laboratories. The Building Agent(tm) provides aggregated and coherent access to building data, including electric energy, thermal energy, temperatures, humidity, and lighting levels, and occupant feedback, which are displayed in various manners for visitors, building occupants, facility managers, and researchers. This paper focuseson the development of visualizations for facility managers, or an energy performance assurance role, where metered data are used to generate models that provide live predicted ranges of building performance by end use. These predicted ranges provide simple, visual context for displayed performance data without requiring users to also assess historical information or trends. Several energymodelling techniques were explored including static lookup-based performance targets, reduced-order models derived from historical data using main effect variables such as solar radiance for lighting performance, and integrated energy models using a whole-building energy simulation program.

  13. InterTechnology Corporation report of solar energy systems installation costs for selected commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-12-01

    The results of a study in which the primary objective was to determine actual costs associated with the installation of solar collector and thermal energy storage subsystems in specific non-residential building applications are presented. A secondary objective of the study was to assemble details of existing solar collector and storage subsystem installations, including caveats concerning cost estimating, logistics and installation practices. The study began with the development of an exhaustive listing and compilation of basic data and contacts for non-residential applications of solar heating and cooling of buildings. Both existing projects and those under construction were surveyed. Survey summary sheets for each project encountered are provided as a separate appendix. Subsequently, the rationale used to select the projects studied in-depth is presented. The results of each of the detailed studies are then provided along with survey summary sheets for each of the projects studied. Installation cost data are summarized and the significance of the differences and similarities between the reported projects is discussed. After evaluating the data obtained from the detailed studies, methods for reducing installation labor costs are postulated based on the experience of the study. Some of the methods include modularization of collectors, preplumbing and preinsulating, and collector placement procedures. Methods of cost reduction and a summary discussion of prominent problems encountered in the projects are considered.(WHK)

  14. Intertechnology Corporation proposed test and evaluation plan, commercial buildings. National Solar Demonstration Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-09-01

    This report has three major parts. The first of these derives the requirements for the Test and Evaluation plan from the System Level Plan which is summarized in Section II. The second part contains the proposed plan to fill these requirements and includes hardware and software recommendations as well as procedures and management considerations. Primary emphasis has been given to the remote site because this is the area in which the commercial part of the demonstration is most unique. Finally, some pre-demonstration activities are described. The pilot program is intended to resolve a number of issues which arose in the course of the T and E plan. These relate to choice of scan frequencies, compression algorithms, etc. It is also intended to confirm performance and cost effectiveness of the site data collection package. The base line measurements of attitudes, etc. provide a reference mark against which one can measure the non-technical effectiveness of the demonstration program. (WDM)

  15. Building a fingerprint database for modern art materials: PIXE analysis of commercial painting and drawing media

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, A., E-mail: alessandro.zucchiatti@uam.es [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Climent-Font, A. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Departamento de Física Aplicada, Universidad Autónoma de Madrid, Avda. Francisco Tomás y Valiente 7, 28049 Madrid (Spain); Gómez-Tejedor, J. García [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain); Martina, S. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Universitá degli Studi di Torino, Turin (Italy); Muro García, C.; Gimeno, E.; Hernández, P.; Canelo, N. [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain)

    2015-11-15

    We have examined by PIXE (and by RBS in parallel) about 180 samples of commercial painting and drawing media including pencils, pastels, waxes, inks, paints and paper. Given the high PIXE sensitivity we produced X-ray spectra at low collected charges and currents, operating in good conservation conditions. For drawing media containing inorganic components or a unique marker element, we have defined colouring agent fingerprints which correspond, when applicable, to the composition declared by the manufacturer. For thin layers, the ratios of areal densities of elements are close to those expected given the declared composition, which is promising from the perspective of compiling the database. The quantitative PIXE and RBS analysis of part of the set of samples is provided.

  16. Making Energy-Efficiency and Productivity Investments in Commercial Buildings: Choice of Investment Models

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.W.

    2002-05-16

    This study examines the decision to invest in buildings and the types of investment decision rules that may be employed to inform the ''go--no go'' decision. There is a range of decision making tools available to help in investment choices, which range from simple rules of thumb such as payback periods, to life-cycle analysis, to decision theoretic approaches. Payback period analysis tends to point toward lower first costs, whereas life-cycle analysis tends to minimize uncertainties over future events that can affect profitability. We conclude that investment models that integrate uncertainty offer better explanations for the behavior that is observed, i.e., people tend to delay investments in technologies that life-cycle analysis finds cost-effective, and these models also lead to an alternative set of policies targeted at reducing of managing uncertainty.

  17. The Optimization of a Cogeneration System for Commercial Buildings by the Particle Swarm Optimization

    Science.gov (United States)

    Miyazaki, Takahiko; Akisawa, Atsushi; Kashiwagi, Takao

    The cogeneration system provides electricity as well as heating and cooling, which consequently leads to a complexity of the design and operation of the system. It requires, therefore, the optimization of parameters such as the number of machines and the capacity of equipment. Generally, the problem can be expressed as a mixed integer nonlinear programming problem, and a lot of efforts would be required to solve it. In this paper, we present a different approach to the optimization of cogeneration systems, which facilitates to find a quasi-optimum solution. The particle swarm optimization combined with a simulation of the system is applied to the minimization of the primary energy consumption and of the system cost. The results present the optimum system constitutions for medium- and large-sized buildings. The result of the system cost minimization under a constraint of the energy saving rate is also discussed.

  18. Participation through Automation: Fully Automated Critical PeakPricing in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote,Sila; Linkugel, Eric

    2006-06-20

    California electric utilities have been exploring the use of dynamic critical peak prices (CPP) and other demand response programs to help reduce peaks in customer electric loads. CPP is a tariff design to promote demand response. Levels of automation in DR can be defined as follows: Manual Demand Response involves a potentially labor-intensive approach such as manually turning off or changing comfort set points at each equipment switch or controller. Semi-Automated Demand Response involves a pre-programmed demand response strategy initiated by a person via centralized control system. Fully Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. The receipt of the external signal initiates pre-programmed demand response strategies. They refer to this as Auto-DR. This paper describes the development, testing, and results from automated CPP (Auto-CPP) as part of a utility project in California. The paper presents the project description and test methodology. This is followed by a discussion of Auto-DR strategies used in the field test buildings. They present a sample Auto-CPP load shape case study, and a selection of the Auto-CPP response data from September 29, 2005. If all twelve sites reached their maximum saving simultaneously, a total of approximately 2 MW of DR is available from these twelve sites that represent about two million ft{sup 2}. The average DR was about half that value, at about 1 MW. These savings translate to about 0.5 to 1.0 W/ft{sup 2} of demand reduction. They are continuing field demonstrations and economic evaluations to pursue increasing penetrations of automated DR that has demonstrated ability to provide a valuable DR resource for California.

  19. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy's Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE's Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  20. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy`s Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE`s Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  1. Building

    OpenAIRE

    Seavy, Ryan

    2014-01-01

    Building for concrete is temporary. The building of wood and steel stands against the concrete to give form and then gives way, leaving a trace of its existence behind. Concrete is not a building material. One does not build with concrete. One builds for concrete. MARCH

  2. Improved Design of Motors for Increased Efficiency in Residential Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Pragasen Pillay

    2008-12-31

    Research progress on understanding magnetic steel core losses is presented in this report. Three major aspects have been thoroughly investigated: 1, experimental characterization of core losses, 2, fundamental physical understanding of core losses and development of core loss formulas, and 3, design of more efficient machine based on the new formulations. Considerable progress has been achieved during the four years of research and the main achievements are summarized in the following: For the experimental characterization, a specially designed advanced commercial test bench was commissioned in addition to the development of a laboratory system with advanced capabilities. The measured properties are core losses at low and higher frequencies, with sinusoidal and non-sinusoidal excitations, at different temperatures, with different measurement apparatus (Toroids, Epstein etc). An engineering-based core loss formula has been developed which considers skin effect. The formula can predict core losses for both sinusoidal and non-sinusoidal flux densities and frequencies up to 4000 Hz. The formula is further tested in electric machines. The formula error range is 1.1% - 7.6% while the standard formulas can have % errors between -8.5% {-+} 44.7%. Two general core loss formulas, valid for different frequencies and thickness, have been developed by analytically and numerically solving Maxwell's equations based on a physical investigation of the dynamic hysteresis effects of magnetic materials. To our knowledge, they are the first models that can offer accurate core loss prediction over a wide range of operating frequencies and lamination thicknesses without a massive experimental database of core losses. The engineering core loss formula has been used with commercial software. The formula performs better than the modified Steinmetz and Bertotti's model used in Cedrat/Magsoft Flux 2D/3D. The new formula shows good correlation with measured results under both

  3. Comparative Study of DC and AC Microgrids in Commercial Buildings Across Different Climates and Operating Profiles: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Fregosi, D.; Ravula, S.; Brhlik, D.; Saussele, J.; Frank, S.; Bonnema, E.; Scheib, J.; Wilson, E.

    2015-04-22

    Bosch has developed and demonstrated a novel DC microgrid system designed to maximize utilization efficiency for locally generated photovoltaic energy while offering high reliability, safety, redundancy, and reduced cost compared to equivalent AC systems. Several demonstration projects validating the system feasibility and expected efficiency gains have been completed and additional ones are in progress. This work gives an overview of the Bosch DC microgrid system and presents key results from a large simulation study done to estimate the energy savings of the Bosch DC microgrid over conventional AC systems. The study examined the system performance in locations across the United States for several commercial building types and operating profiles and found that the Bosch DC microgrid uses generated PV energy 6%–8% more efficiently than traditional AC systems.

  4. Building the institutional capacity for managing commercial high-level radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-05-01

    In July 1981, the Office of Nuclear Waste Management of the Department of Energy contracted with the National Academy of Public Administration for a study of institutional issues associated with the commercial radioactive waste management program. The two major sets of issues which the Academy was asked to investigate were (1) intergovernmental relationships, how federal, state, local and Indian tribal council governments relate to each other in the planning and implementation of a waste management program, and (2) interagency relationships, how the federal agencies with major responsibilities in this public policy arena interact with each other. The objective of the study was to apply the perspectives of public administration to a difficult and controversial question - how to devise and execute an effective waste management program workable within the constraints of the federal system. To carry out this task, the Academy appointed a panel composed of individuals whose background and experience would provide the several types of knowledge essential to the effort. The findings of this panel are presented along with the executive summary. The report consists of a discussion of the search for a radioactive waste management strategy, and an analysis of the two major groups of institutional issues: (1) intergovernmental, the relationship between the three major levels of government; and (2) interagency, the relationships between the major federal agencies having responsibility for the waste management program.

  5. Texas State Building Energy Code: Analysis of Potential Benefits and Costs of Commercial Lighting Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Richman, Eric E.; Belzer, David B.; Winiarski, David W.

    2005-09-15

    The State Energy Conservation Office of Texas has asked the U.S. Department of Energy to analyze the potential energy effect and cost-effectiveness of the lighting requirements in the 2003 IECC as they consider adoption of this energy code. The new provisions of interest in the lighting section of IECC 2003 include new lighting power densities (LPD) and requirements for automatic lighting shutoff controls. The potential effect of the new LPD values is analyzed as a comparison with previous values in the nationally available IECC codes and ASHRAE/IESNA 90.1. The basis for the analysis is a set of lighting models developed as part of the ASHRAE/IES code process, which is the basis for IECC 2003 LPD values. The use of the models allows for an effective comparison of values for various building types of interest to Texas state. Potential effects from control requirements are discussed, and available case study analysis results are provided but no comprehensive numerical evaluation is provided in this limited analysis effort.

  6. Predicting the Texas Windstorm Insurance Association claim payout of commercial buildings from Hurricane Ike

    Directory of Open Access Journals (Sweden)

    J. M. Kim

    2013-08-01

    Full Text Available Following growing public awareness of the danger from hurricanes and tremendous demands for analysis of loss, many researchers have conducted studies to develop hurricane damage analysis methods. Although researchers have identified the significant indicators, there currently is no comprehensive research for identifying the relationship among the vulnerabilities, natural disasters, and economic losses associated with individual buildings. To address this lack of research, this study will identify vulnerabilities and hurricane indicators, develop metrics to measure the influence of economic losses from hurricanes, and visualize the spatial distribution of vulnerability to evaluate overall hurricane damage. This paper has utilized the Geographic Information System to facilitate collecting and managing data, and has combined vulnerability factors to assess the financial losses suffered by Texas coastal counties. A multiple linear regression method has been applied to develop hurricane economic damage predicting models. To reflect the pecuniary loss, insured loss payment was used as the dependent variable to predict the actual financial damage. Geographical vulnerability indicators, built environment vulnerability indicators, and hurricane indicators were all used as independent variables. Accordingly, the models and findings may possibly provide vital references for government agencies, emergency planners, and insurance companies hoping to predict hurricane damage.

  7. Integrated Multi-Scale Data Analytics and Machine Learning for the Distribution Grid and Building-to-Grid Interface

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Emma M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hendrix, Val [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chertkov, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Deka, Deepjyoti [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-16

    This white paper introduces the application of advanced data analytics to the modernized grid. In particular, we consider the field of machine learning and where it is both useful, and not useful, for the particular field of the distribution grid and buildings interface. While analytics, in general, is a growing field of interest, and often seen as the golden goose in the burgeoning distribution grid industry, its application is often limited by communications infrastructure, or lack of a focused technical application. Overall, the linkage of analytics to purposeful application in the grid space has been limited. In this paper we consider the field of machine learning as a subset of analytical techniques, and discuss its ability and limitations to enable the future distribution grid and the building-to-grid interface. To that end, we also consider the potential for mixing distributed and centralized analytics and the pros and cons of these approaches. Machine learning is a subfield of computer science that studies and constructs algorithms that can learn from data and make predictions and improve forecasts. Incorporation of machine learning in grid monitoring and analysis tools may have the potential to solve data and operational challenges that result from increasing penetration of distributed and behind-the-meter energy resources. There is an exponentially expanding volume of measured data being generated on the distribution grid, which, with appropriate application of analytics, may be transformed into intelligible, actionable information that can be provided to the right actors – such as grid and building operators, at the appropriate time to enhance grid or building resilience, efficiency, and operations against various metrics or goals – such as total carbon reduction or other economic benefit to customers. While some basic analysis into these data streams can provide a wealth of information, computational and human boundaries on performing the analysis

  8. The Viewpoint of Advertisements Installation in Commercial Buildings%关于商业建筑立面中广告设置的一些思考

    Institute of Scientific and Technical Information of China (English)

    王诗朗

    2014-01-01

    在商业建筑中,立面广告是重要的组成部分。但是不加以组织和控制的立面广告会破坏商业建筑的整体效果。本文试图从广告模式、复合设计以及新技术的应用三个角度,对如何整合商业建筑立面与广告这个问题提出一些思考。%Facade advertisements have been the significant part of commercial building. However the advertisement without elaborative design may do harm to the overal effect of the commercial buildings. For the problem of integration between commercial buildings` facade and advertisements, this paper elaborates from three aspects:advertising model, integrated design, new technology.

  9. Assessing the effects of building social intelligence in a robotic interface for the home

    NARCIS (Netherlands)

    Ruyter, B.E.R. de; Saini, P.; Markopoulos, P.; Breemen, A. van

    2005-01-01

    This paper reports an exploration of the concept of social intelligence in the context of designing home dialogue systems for an Ambient Intelligence home. It describes a Wizard of Oz experiment involving a robotic interface capable of simulating several human social behaviours. Our results show tha

  10. Next-generation heat pump systems in residential buildings and commercial premises; Naesta generations vaermepumpssystem i bostaeder och lokaler

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Lindahl, Markus; Alsbjer, Markus; Nordman, Roger; Rolfsman, Lennart; Axell, Monica

    2009-07-01

    Summarising, the following conclusions can be drawn from this work. - Installation of a heat pump system is a very efficient way of reducing a building's energy demand without making any greater changes to the building's climate screen, and can therefore assist Sweden's achievement of its energy efficiency improvement targets. - A new generation of cost-effective smaller heat pumps is needed for installation in new detached houses or those being renovated and upgraded. - There also seems to be an excellent market potential for heat pumps that are larger than has previously been common: there should be good prospects for selling them for use in apartment buildings and in commercial or similar premises. - Heat pump installations are particularly competitive in applications where there are simultaneous heating and cooling demands in the property, and also in those cases where heating is required for most of the year and cooling for some other part of the year. If these suggested system arrangements are to be fully realised, there will be a need for further research in certain cases. Particularly, there is a need for research and development of more efficient pumps, fans and speed-controlled compressors in order to get such products on to the market. Performance measurements and follow-up of real systems are needed in order to obtain a clear picture of the efficiency of both present-day and proposed systems. This knowledge is essential for further development of systems, not only for residential buildings but also, even more importantly, for commercial and similar premises. Actual heating and cooling requirements in different types of non-residential premises need to be known more accurately in order to decide how systems should be controlled in order to minimise total energy use. Much indicates that future detached houses will be more energy-efficient, which could have the undesirable result of greater use of direct electric heating, as the investment

  11. Next-generation heat pump systems in residential buildings and commercial premises; Naesta generations vaermepumpssystem i bostaeder och lokaler

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Lindahl, Markus; Alsbjer, Markus; Nordman, Roger; Rolfsman, Lennart; Axell, Monica

    2009-07-01

    Summarising, the following conclusions can be drawn from this work. - Installation of a heat pump system is a very efficient way of reducing a building's energy demand without making any greater changes to the building's climate screen, and can therefore assist Sweden's achievement of its energy efficiency improvement targets. - A new generation of cost-effective smaller heat pumps is needed for installation in new detached houses or those being renovated and upgraded. - There also seems to be an excellent market potential for heat pumps that are larger than has previously been common: there should be good prospects for selling them for use in apartment buildings and in commercial or similar premises. - Heat pump installations are particularly competitive in applications where there are simultaneous heating and cooling demands in the property, and also in those cases where heating is required for most of the year and cooling for some other part of the year. If these suggested system arrangements are to be fully realised, there will be a need for further research in certain cases. Particularly, there is a need for research and development of more efficient pumps, fans and speed-controlled compressors in order to get such products on to the market. Performance measurements and follow-up of real systems are needed in order to obtain a clear picture of the efficiency of both present-day and proposed systems. This knowledge is essential for further development of systems, not only for residential buildings but also, even more importantly, for commercial and similar premises. Actual heating and cooling requirements in different types of non-residential premises need to be known more accurately in order to decide how systems should be controlled in order to minimise total energy use. Much indicates that future detached houses will be more energy-efficient, which could have the undesirable result of greater use of direct electric heating, as the investment

  12. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-1999 as a Commercial Building Energy Code in Illinois Jurisdictions

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, David B.; Cort, Katherine A.; Winiarski, David W.; Richman, Eric E.; Friedrich, Michele

    2002-05-01

    ASHRAE Standard 90.1-1999 was developed in an effort to set minimum requirements for energy efficienty design and construction of new commercial buildings. This report assesses the benefits and costs of adopting this standard as the building energy code in Illinois. Energy and economic impacts are estimated using BLAST combined with a Life-Cycle Cost approach to assess corresponding economic costs and benefits.

  13. A hamiltonian replica exchange method for building protein-protein interfaces applied to a leucine zipper.

    Science.gov (United States)

    Cukier, Robert I

    2011-01-28

    Leucine zippers consist of alpha helical monomers dimerized (or oligomerized) into alpha superhelical structures known as coiled coils. Forming the correct interface of a dimer from its monomers requires an exploration of configuration space focused on the side chains of one monomer that must interdigitate with sites on the other monomer. The aim of this work is to generate good interfaces in short simulations starting from separated monomers. Methods are developed to accomplish this goal based on an extension of a previously introduced [Su and Cukier, J. Phys. Chem. B 113, 9595, (2009)] hamiltonian temperature replica exchange method (HTREM), which scales the hamiltonian in both potential and kinetic energies that was used for the simulation of dimer melting curves. The new method, HTREM_MS (MS designates mean square), focused on interface formation, adds restraints to the hamiltonians for all but the physical system, which is characterized by the normal molecular dynamics force field at the desired temperature. The restraints in the nonphysical systems serve to prevent the monomers from separating too far, and have the dual aims of enhancing the sampling of close in configurations and breaking unwanted correlations in the restrained systems. The method is applied to a 31-residue truncation of the 33-residue leucine zipper (GCN4-p1) of the yeast transcriptional activator GCN4. The monomers are initially separated by a distance that is beyond their capture length. HTREM simulations show that the monomers oscillate between dimerlike and monomerlike configurations, but do not form a stable interface. HTREM_MS simulations result in the dimer interface being faithfully reconstructed on a 2 ns time scale. A small number of systems (one physical and two restrained with modified potentials and higher effective temperatures) are sufficient. An in silico mutant that should not dimerize because it lacks charged residues that provide electrostatic stabilization of the dimer

  14. A Hamiltonian replica exchange method for building protein-protein interfaces applied to a leucine zipper

    Science.gov (United States)

    Cukier, Robert I.

    2011-01-01

    Leucine zippers consist of alpha helical monomers dimerized (or oligomerized) into alpha superhelical structures known as coiled coils. Forming the correct interface of a dimer from its monomers requires an exploration of configuration space focused on the side chains of one monomer that must interdigitate with sites on the other monomer. The aim of this work is to generate good interfaces in short simulations starting from separated monomers. Methods are developed to accomplish this goal based on an extension of a previously introduced [Su and Cukier, J. Phys. Chem. B 113, 9595, (2009)] Hamiltonian temperature replica exchange method (HTREM), which scales the Hamiltonian in both potential and kinetic energies that was used for the simulation of dimer melting curves. The new method, HTREM_MS (MS designates mean square), focused on interface formation, adds restraints to the Hamiltonians for all but the physical system, which is characterized by the normal molecular dynamics force field at the desired temperature. The restraints in the nonphysical systems serve to prevent the monomers from separating too far, and have the dual aims of enhancing the sampling of close in configurations and breaking unwanted correlations in the restrained systems. The method is applied to a 31-residue truncation of the 33-residue leucine zipper (GCN4-p1) of the yeast transcriptional activator GCN4. The monomers are initially separated by a distance that is beyond their capture length. HTREM simulations show that the monomers oscillate between dimerlike and monomerlike configurations, but do not form a stable interface. HTREM_MS simulations result in the dimer interface being faithfully reconstructed on a 2 ns time scale. A small number of systems (one physical and two restrained with modified potentials and higher effective temperatures) are sufficient. An in silico mutant that should not dimerize because it lacks charged residues that provide electrostatic stabilization of the dimer

  15. Architecture and pervasive Computing when buildings and design artifacts become popular interfaces

    DEFF Research Database (Denmark)

    Krogh, Peter Gall; Grønbæk, Kaj

    2001-01-01

    computing we are on the brink of an even greater increase: IT components and systems for intelligent buildings will change from being proprietary, specialized solutions with a narrow market to be part of the developing mainstream mass market for pervasive computing. This paper will illustrate...

  16. Double network bacterial cellulose hydrogel to build a biology-device interface.

    Science.gov (United States)

    Shi, Zhijun; Li, Ying; Chen, Xiuli; Han, Hongwei; Yang, Guang

    2014-01-21

    Establishing a biology-device interface might enable the interaction between microelectronics and biotechnology. In this study, electroactive hydrogels have been produced using bacterial cellulose (BC) and conducting polymer (CP) deposited on the BC hydrogel surface to cover the BC fibers. The structures of these composites thus have double networks, one of which is a layer of electroactive hydrogels combined with BC and CP. The electroconductivity provides the composites with capabilities for voltage and current response, and the BC hydrogel layer provides good biocompatibility, biodegradability, bioadhesion and mass transport properties. Such a system might allow selective biological functions such as molecular recognition and specific catalysis and also for probing the detailed genetic and molecular mechanisms of life. A BC-CP composite hydrogel could then lead to a biology-device interface. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) are used here to study the composite hydrogels' electroactive property. BC-PAni and BC-PPy respond to voltage changes. This provides a mechanism to amplify electrochemical signals for analysis or detection. BC hydrogels were found to be able to support the growth, spreading and migration of human normal skin fibroblasts without causing any cytotoxic effect on the cells in the cell culture. These double network BC-CP hydrogels are biphasic Janus hydrogels which integrate electroactivity with biocompatibility, and might provide a biology-device interface to produce implantable devices for personalized and regenerative medicine.

  17. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Patrick O' Neill

    2009-06-30

    This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests

  18. 居住区商业建筑设计探析%Initial analysis on design of commercial building in residential district

    Institute of Scientific and Technical Information of China (English)

    乔飞

    2009-01-01

    Combining with the development process and development situation of Chinese commercial building in residential district, the author describes the planning thought of the commercial building in residential district and the idea principle which should be followed in design proeess, provides getting whole process design and distinctive creation of the commercial building in residential district, so as to improve and perfeet the design level of the commercial building in residential district.%结合我国居住区商业建筑的发展演变进程和发展现状,阐述了居住区商业建筑规划思路和设计过程中应遵循的理念原则,提出居住区商业建筑应进行全过程设计及有特色的创造,以期提高和完善居住区商业建筑设计水平.

  19. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-2001 as the Commercial Building Energy Code in Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Winiarski, David W.; Belzer, David B.; Richman, Eric E.

    2004-09-30

    ASHRAE Standard 90.1-2001 Energy Standard for Buildings except Low-Rise Residential Buildings (hereafter referred to as ASHRAE 90.1-2001 or 90.1-2001) was developed in an effort to set minimum requirements for the energy efficient design and construction of new commercial buildings. The State of Tennessee is considering adopting ASHRAE 90.1-2001 as its commercial building energy code. In an effort to evaluate whether or not this is an appropriate code for the state, the potential benefits and costs of adopting this standard are considered in this report. Both qualitative and quantitative benefits and costs are assessed. Energy and economic impacts are estimated using the Building Loads Analysis and System Thermodynamics (BLAST) simulations combined with a Life-Cycle Cost (LCC) approach to assess corresponding economic costs and benefits. Tennessee currently has ASHRAE Standard 90A-1980 as the statewide voluntary/recommended commercial energy standard; however, it is up to the local jurisdiction to adopt this code. Because 90A-1980 is the recommended standard, many of the requirements of ASHRAE 90A-1980 were used as a baseline for simulations.

  20. Analysis of Energy Air Conditioning Consumption Management in Commercial Buildings%公共建筑空调系统运行能耗管理分析

    Institute of Scientific and Technical Information of China (English)

    王洪卫

    2012-01-01

    公共建筑成为建筑中的用能大户,其空调系统高能耗问题逐渐突出。通过对商场、宾馆、办公楼和综合性建筑等类型的公共建筑的能耗调研,对公共建筑空调系统能耗状况及空调系统运行管理的现状进行分析。认为公共建筑集中空调系统用能水平和运行管理水平较低是空调系统能耗在建筑运行过程中高能耗的原因,合理的采暖空调能耗管理制度是公共建筑节能的关键环节。%Energy consumption of the commercial buildings is the most part of energy consumption of buildings, and energy consumption in central air conditioning is the important part of energy consumption in commercial buildings. In order to obtain the status of energy consumption in central air conditioning of commercial buildings, investigates energy consump- tion in stores, hotels, offices and so on. Assesses the energy consumption and management situation of commercial buildings. Points out that the level of building energy use and managements is low, which is the reason of high energy consumption. Reasonable management of energy consumption is the key factor of energy efficiency of central air conditioning.

  1. Regulation proposal for voluntary energy efficiency labelling of commercial buildings; Regulamentacao de etiquetagem voluntaria de nivel de eficiencia energetica de edificios comerciais e publicos

    Energy Technology Data Exchange (ETDEWEB)

    Lamberts, Roberto; Goulart, Solange; Carlo, Joyce; Westphal, Fernando [Universidade Federal de Santa Catarina (UFSC/LabEEE), Florianopolis, SC (Brazil). Lab. de Eficiencia Energetica em Edificacoes], e-mail: lamberts@ecv.ufsc.br, e-mail: solange@labeee.ufsc.br, e-mail: joyce@labeee.ufsc.br, e-mail: fernando@labeee.ufsc.br

    2006-07-01

    Despite of Brazil not being between the major world energy consumers, the consumption of electricity has significantly increased in the late years. The National Energy Balance of 2005, published by the Brazilian Ministry of Energy, showed an increasing of the participation of electricity in the final energy consumption of 15.7% in 2002 to 16.2% in 2004. Initially, a brief review of the initiatives taken by Brazilian Government aiming to limit and control the energy consumption in buildings is presented. Then, the regulation proposal containing the technical requirements to classify the energy efficiency level of buildings is shown. The purpose of this voluntary regulation is to provide conditions to certify the energy efficiency level of Brazilian buildings (commercial and public). It specifies the methods for energy efficiency rating of buildings and includes requirements to attend energy conservation measures in three main issues: lighting system; air conditioning system and envelope. The regulation applies to large buildings (minimum total area of 500 m{sup 2} or when the energy demand is greater than or equal to 2,3 kV, including: Conditioned buildings; Partially conditioned buildings and Naturally ventilated buildings. (author)

  2. Tool coupling for the design and operation of building energy and control systems based on the Functional Mock-up Interface standard

    Energy Technology Data Exchange (ETDEWEB)

    Nouidui, Thierry Stephane; Wetter, Michael

    2014-03-01

    This paper describes software tools developed at the Lawrence Berkeley National Laboratory (LBNL) that can be coupled through the Functional Mock-up Interface standard in support of the design and operation of building energy and control systems. These tools have been developed to address the gaps and limitations encountered in legacy simulation tools. These tools were originally designed for the analysis of individual domains of buildings, and have been difficult to integrate with other tools for runtime data exchange. The coupling has been realized by use of the Functional Mock-up Interface for co-simulation, which standardizes an application programming interface for simulator interoperability that has been adopted in a variety of industrial domains. As a variety of coupling scenarios are possible, this paper provides users with guidance on what coupling may be best suited for their application. Furthermore, the paper illustrates how tools can be integrated into a building management system to support the operation of buildings. These tools may be a design model that is used for real-time performance monitoring, a fault detection and diagnostics algorithm, or a control sequence, each of which may be exported as a Functional Mock-up Unit and made available in a building management system as an input/output block. We anticipate that this capability can contribute to bridging the observed performance gap between design and operational energy use of buildings.

  3. Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Blum, Helcio; Sathaye, Jayant

    2010-05-14

    We investigate the existence of the principal-agent (PA) problem in non-government, non-mall commercial buildings in the U.S. in 2003. The analysis concentrates on space heating and cooling energy consumed by centrally installed equipment in order to verify whether a market failure caused by the PA problem might have prevented the installation of energy-efficient devices in non-owner-occupied buildings (efficiency problem) and/or the efficient operation of space-conditioning equipment in these buildings (usage problem). Commercial Buildings Energy Consumption Survey (CBECS) 2003 data for single-owner, single-tenant and multi-tenant occupied buildings were used for conducting this evaluation. These are the building subsets with the appropriate conditions for assessing both the efficiency and the usage problems. Together, these three building types represent 51.9percent of the total floor space of all buildings with space heating and 59.4percent of the total end-use energy consumption of such buildings; similarly, for space cooling, they represent 52.7percent of floor space and 51.6percent of energy consumption. Our statistical analysis shows that there is a usage PA problem. In space heating it applies only to buildings with a small floor area (<_50,000 sq. ft.). We estimate that in 2003 it accounts for additional site energy consumption of 12.3 (+ 10.5 ) TBtu (primary energy consumption of 14.6 [+- 12.4] TBtu), corresponding to 24.0percent (+- 20.5percent) of space heating and 10.2percent (+- 8.7percent) of total site energy consumed in those buildings. In space cooling, however, the analysis shows that the PA market failure affects the complete set of studied buildings. We estimate that it accounts for a higher site energy consumption of 8.3 (+-4.0) TBtu (primary energy consumption of 25.5 [+- 12.2]TBtu), which corresponds to 26.5percent (+- 12.7percent) of space cooling and 2.7percent (+- 1.3percent) of total site energy consumed in those buildings.

  4. Geomorphology and the urban tropics: building an interface between research and usage

    Science.gov (United States)

    Gupta, Avijit; Ahmad, Rafi

    1999-12-01

    The developing countries, located almost entirely within the tropics, are currently undergoing urbanization at a rapid pace. Many of these cities are not more than a few centuries old, having been established to function as regional trading posts or administrative centers by either colonial or regional powers. It is doubtful that the site conditions were taken into consideration, and consequently, many of these cities were established in hazardous or environmentally sensitive areas. As these cities developed over time, they spread across a wide range of terrain conditions much of which are unsuitable, such as floodplains, coastal swamps, steep slopes, or sand dunes. For a number of these cities, which are located near active plate margins and tropical cyclone belts, such problems are magnified. Increased demand for water has required subsurface extraction, leading to problems of subsidence and quality. We examine the range of these cities with reference to (1) their site-related problems, (2) the nature of geomorphological information required for specific ameliorating actions, and (3) the level of management required for city maintenance. Management requires interfacing geomorphology with engineering practices and urban planning. We present case studies of cities ranging from those with limited problems and possible engineering and land-zoning solutions (Singapore) to cities where the hazards (either natural or anthropogenic) are so acute and widespread that a practical solution is difficult to achieve (Kingston, Bangkok). Precise geomorphological and geological information and long-term data sets are not available for most of the cities. Furthermore, it is necessary to present the information in formats appreciated by the engineering and planning communities. Often a set of specialized maps are extremely useful. We complete the discussion with several examples and suggestions for collection of geomorphological information and inventory preparation for

  5. Analysis of Potential Benefits and Costs of Adopting ASHRAE Standard 90.1-1999 as a Commercial Building Energy Code in Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Belzer, David B.; Halverson, Mark A.; Richman, Eric E.; Winiarski, David W.

    2002-09-30

    The state of Michigan is considering adpoting ASHRAE 90.1-1999 as its commercial building energy code. In an effort to evaluate whether or not this is an appropraite code for the state, the potential benefits and costs of adopting this standard are considered. Both qualitative and quantitative benefits are assessed. The energy simulation and economic results suggest that adopting ASHRAE 90.1-1999 would provide postitive net benefits to the state relative to the building and design requirements currently in place.

  6. Reducing Mortality from Terrorist Releases of Chemical and Biological Agents: I. Filtration for Ventilation Systems in Commercial Building

    Energy Technology Data Exchange (ETDEWEB)

    Thatcher, Tracy L.; Daisey, Joan M.

    1999-09-01

    There is growing concern about potential terrorist attacks involving releases of chemical and/or biological (CB) agents, such as sarin or anthrax, in and around buildings. For an external release, the CB agent can enter the building through the air intakes of a building's mechanical ventilation system and by infiltration through the building envelope. For an interior release in a single room, the mechanical ventilation system, which often recirculates some fraction of the air within a building, may distribute the released CB agent throughout the building. For both cases, installing building systems that remove chemical and biological agents may be the most effective way to protect building occupants. Filtration systems installed in the heating, ventilating and air-conditioning (HVAC) systems of buildings can significantly reduce exposures of building occupants in the event of a release, whether the release is outdoors or indoors. Reduced exposures can reduce the number of deaths from a terrorist attack. The purpose of this report is to provide information and examples of the design of filtration systems to help building engineers retrofit HVAC systems. The report also provides background information on the physical nature of CB agents and brief overviews of the basic principles of particle and vapor filtration.

  7. Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing

    Energy Technology Data Exchange (ETDEWEB)

    Price, Phillip N.; Granderson, Jessica; Sohn, Michael; Addy, Nathan; Jump, David

    2013-09-01

    The overarching goal of this work is to advance the capabilities of technology evaluators in evaluating the building-level baseline modeling capabilities of Energy Management and Information System (EMIS) software. Through their customer engagement platforms and products, EMIS software products have the potential to produce whole-building energy savings through multiple strategies: building system operation improvements, equipment efficiency upgrades and replacements, and inducement of behavioral change among the occupants and operations personnel. Some offerings may also automate the quantification of whole-building energy savings, relative to a baseline period, using empirical models that relate energy consumption to key influencing parameters, such as ambient weather conditions and building operation schedule. These automated baseline models can be used to streamline the whole-building measurement and verification (M&V) process, and therefore are of critical importance in the context of multi-measure whole-building focused utility efficiency programs. This report documents the findings of a study that was conducted to begin answering critical questions regarding quantification of savings at the whole-building level, and the use of automated and commercial software tools. To evaluate the modeling capabilities of EMIS software particular to the use case of whole-building savings estimation, four research questions were addressed: 1. What is a general methodology that can be used to evaluate baseline model performance, both in terms of a) overall robustness, and b) relative to other models? 2. How can that general methodology be applied to evaluate proprietary models that are embedded in commercial EMIS tools? How might one handle practical issues associated with data security, intellectual property, appropriate testing ‘blinds’, and large data sets? 3. How can buildings be pre-screened to identify those that are the most model-predictable, and therefore those

  8. Investigation and Analysis on Energy Consumption of Commercial Office Buildings%商务办公建筑能耗调研及分析

    Institute of Scientific and Technical Information of China (English)

    陈晓欣; 李永安

    2016-01-01

    对山东某地区商务办公建筑进行了调研。应用抽样调查的方法,对该地区37个样本量的能耗进行统计处理,得出了该地区单位面积建筑能耗为72.14 kW·h/(m2·a),单位面积供暖能耗为14.74 kgce/(m2·a)。研究结果表明,山东某地区的商务办公建筑在用能方面还存在一些问题,建筑节能潜力较大。这对于科学确定商务办公建筑的能耗指标,进而实施用能超定额加价政策具有一定的参考价值。%The method of sampling investigation is utilized to survey the energy consumption about 37 commercial office buildings in Shandong. The conclusion shows that the building energy consumption per unit area is 72.14 kW·h/(m2·a) and the heating energy consumption per unit area is 14.74 kgce/(m2·a). According to the research, although there are some problems about energy consumption in local commercial office buildings, it shows great potentials in building energy efficiency. The research will determine the energy consumption index for commercial office building scientifically to implement price increasing policy if the energy consumption excesses the quota.

  9. 浅谈大型商业建筑设计要点%On the Key Points of the Design of Large Commercial Buildings

    Institute of Scientific and Technical Information of China (English)

    张郁

    2015-01-01

    The rapid growth of economy makes people pay attention to the development potential of today's commercial circles. The world is tending towards peace and development, so violent profits has become an unlikely way. But the war did not therefore dispersed. In the continuous development of society, another intangible battlefield quietly filled the war atmosphere. It is the commercial war. Although there are no soldiers, there is murderous look. As a carrier of commercial development, commercial building's value is embodied. Without a commercial building good in quality and quantity, the development of commercial circle is impossible, and the commercial construction environment is unable to construct, so the design essentials of the commercial building is particularly important.%经济的迅猛提升使人们关注到了当今商业圈的发展潜力,在世界趋于和平发展的过程中,暴力谋取利润已经成为了一种不可能的方式。但是战争的硝烟却并没有因此而散去,在社会不断发展变革的过程中,另一处无形的战场悄然弥漫了战争的气息。那就是商业硝烟的弥漫。虽不见万千军马奔腾,但杀气却丝毫不逊色于当年的战场。而作为商业发展的一个载体,商业建筑的价值就得到了体现,如果没有一个保质保量的商业建筑,那么商业圈的发展就无从谈起,商业建设的大环境就无法构造,所以在进行设计要点在商业建筑过程中尤为重要。

  10. Owgis 2.0: Open Source Java Application that Builds Web GIS Interfaces for Desktop Andmobile Devices

    Science.gov (United States)

    Zavala Romero, O.; Chassignet, E.; Zavala-Hidalgo, J.; Pandav, H.; Velissariou, P.; Meyer-Baese, A.

    2016-12-01

    OWGIS is an open source Java and JavaScript application that builds easily configurable Web GIS sites for desktop and mobile devices. The current version of OWGIS generates mobile interfaces based on HTML5 technology and can be used to create mobile applications. The style of the generated websites can be modified using COMPASS, a well known CSS Authoring Framework. In addition, OWGIS uses several Open Geospatial Consortium standards to request datafrom the most common map servers, such as GeoServer. It is also able to request data from ncWMS servers, allowing the websites to display 4D data from NetCDF files. This application is configured by XML files that define which layers, geographic datasets, are displayed on the Web GIS sites. Among other features, OWGIS allows for animations; streamlines from vector data; virtual globe display; vertical profiles and vertical transects; different color palettes; the ability to download data; and display text in multiple languages. OWGIS users are mainly scientists in the oceanography, meteorology and climate fields.

  11. Development of a methodology for defining whole-building energy design targets for commercial buildings: Phase 2, Development Concept Stage Report

    Energy Technology Data Exchange (ETDEWEB)

    McKay, H.N. (Illuminating Engineering Society of North America, New York, NY (USA)); Deringer, J.J. (American Inst. of Architects, Washington, DC (USA)); Jones, J.W. (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA (USA)); Hall, J.D. (Deringer Group, Riva, MD (USA))

    1990-09-01

    This report documents eight tasks performed as part of the Whole-Building Energy Design Targets project, in which detailed conceptual approaches were produced for each element of the proposed Targets model. The eight task reports together describe the important modules proposed for inclusion in the Targets model: input module, energy module, characteristic development moduel, building cost module, analysis control module, energy cost module, search routines module, and economic analysis module. 16 refs., 16 figs., 5 tabs.

  12. Environmental Assessment Methodologies for Commercial Buildings: An Elicitation Study of U.S. Building Professionals’ Beliefs on Leadership in Energy and Environmental Design (LEED

    Directory of Open Access Journals (Sweden)

    Jasmin Kientzel

    2011-12-01

    Full Text Available Voluntary environmental programs (VEPs have become increasingly popular around the world to address energy efficiency issues that mandatory building codes have not been able to tackle. Even though the utility of voluntary schemes is widely debated, they have become a de facto reality for many professionals in the building and construction sector. One topic that is neglected, however, in both academic and policy discussions, relates to how professionals (architects, engineers, real estate developers, etc. perceive the rise of voluntary rating schemes. In order to fill this gap in the literature, the present study investigates beliefs underlying adoption behavior regarding one of the most prominent voluntary assessment and certification programs in the U.S. building industry, the Leadership in Energy and Environmental Design (LEED scheme. In this paper, an elicitation study, based on 14 semi-structured interviews with building professionals in the North East of the United States, was conducted to analyze this question. Building on the Reasoned Action Approach, this paper shows that, in addition to more conventional factors such as financial calculations and marketing aspects, the understanding of beliefs held by building professionals offers important insights into their decisions to work with Voluntary Environmental Assessment and Rating Programs.

  13. Commercial-sector energy-consumption data-base-development project. Volume III. Analysis of energy consumption in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-04-01

    Results are presented of an effort to develop comprehensive and reliable energy consumption data for office buildings. A survey was conducted of readily available energy consumption data and the literature that describes the factors which drive energy use in such buildings was analyzed. Information on heating, ventilating, and air conditioning (HVAC) systems was assembled. A number of building energy use simulation programs were reviewed to determine their suitability for estimating energy consumption by function and the effects of tradeoffs in building design and operating parameters on building energy use. Simulations using the AXCESS program were conducted. The 1975 data base of the Building Owners and Managers Association (BOMA) was obtained and analyzed. Data describing energy use on a regional and national basis were developed, and regression equations based on these were obtained. The ability of these equations to predict average energy use was then confirmed by applying them to four office buildings not in the BOMA data base. A number of proposals for the further improvement of the equations were developed, including additional data collection. Specifically, the survey of actual and simulated data on a regional basis is reported in Section 2. HVAC systems are discussed in Sections 3 and 4. BOMA obtains annual data on about 1000 buildings covering such items as location, floor area, height, age, average occupancy rate, average number of employees, types of tenants, type of air conditioning, and energy consumption by fuel and the description and analyses of the BOMA data are presented in Sections 5 and 6.

  14. SPECIAL COLLOQUIUM : Building a Commercial Space Launch System and the Role of Space Tourism in the Future (exceptionally on Tuesday)

    CERN Document Server

    CERN. Geneva

    2010-01-01

    The talk will explore a little of the history of space launch systems and rocketry, will explain why commercial space tourism did not take off after Apollo, and what is happening right now with commercial space systems such as Virgin's, utilising advances in aerospace technology not exploited by conventional ground-based rocket systems. I will then explain the Virgin Galactic technology, its business plan as a US-regulated space tourism company, and the nature of its applications. I will then go on to say a little of how our system can be utilised for sub-orbital space science based on a commercial business plan

  15. Measuring local genetic variability in populations of codling moth (Lepidoptera: Tortricidae) across an unmanaged and commercial orchard interface.

    Science.gov (United States)

    Fuentes-Contreras, Eduardo; Basoalto, Esteban; Franck, Pierre; Lavandero, Blas; Knight, Alan L; Ramírez, Claudio C

    2014-04-01

    The genetic structure of adult codling moth, Cydia pomonella (L.), populations was characterized both inside a managed apple, Malus domestica Borkdhausen, orchard and in surrounding unmanaged hosts and nonhost trees in central Chile during 2006-2007. Adult males were collected using an array of sex pheromone-baited traps. Five microsatellite genetic markers were used to study the population genetic structure across both spatial (1-100 ha) and temporal (generations within a season) gradients. Analysis of molecular variance (AMOVA) found a significant, but weak, association in both the spatial and temporal genetic structures. Discriminant analysis also found significant differentiation between the first and second generation for traps located either inside or outside the managed orchard. The Bayesian assignment test detected three genetic clusters during each of the two generations, which corresponded to different areas within the unmanaged and managed apple orchard interface. The lack of a strong spatial structure at a local scale was hypothesized to be because of active adult movement between the managed and unmanaged hosts and the asymmetry in the insecticide selection pressure inside and outside the managed habitats. These data highlight the importance of developing area-wide management programs that incorporate management tactics effective at the landscape level for successful codling moth control.

  16. Future comfort cooling in domestic and commercial buildings in Sweden; Naesta generations klimatkyla i bostaeder och lokaler

    Energy Technology Data Exchange (ETDEWEB)

    Nordman, Roger; Haglund Stignor, Caroline; Rolfsman, Lennart; Lindahl, Markus; Alsbjer, Markus; Axell, Monica

    2010-09-15

    This report presents results from a national project on future potential for comfort cooling in the built sector. Results from an interview study are presented. Future changes in energy demand for comfort cooling in different building types based on scenarios are also presented and discussed. It is clear from the simulated results that the future need for comfort cooling will decrease due to a number of factors, including user behavior, regulations and new building codes

  17. Research on Building Envelope Energy Conservation for Commercial Buildings in Hot Summer and Warm Winter Zone%夏热冬暖地区商业建筑围护结构节能研究

    Institute of Scientific and Technical Information of China (English)

    马杰; 聂金哲; 冯莹莹; 李晓锋

    2012-01-01

    In recent years, studies on building energy conservation in hot summer and warm winter zone were mainly focused on residential buildings and office buildings, but not for the large commercial buildings which consumed highest energy per unit area. Furthermore, these studies were mainly concentrated on HVAC system,while the design of building envelope was not well concerned. In this paper,the energy consumption of a commercial building in Guangzhou was simulated using the software of DeST,and the building envelope was optimized by analyzing the energy conservation performance with different structure combinations. The results indicated that the sunshade and ventilation could play an important role for building energy conservation. In addition, the suggestions for optimizing the building envelope design were provided.%近年来,夏热冬暖地区的建筑节能研究多集中在住宅建筑和办公建筑,而对单位建筑面积能耗最高的大型商业建筑研究较少.且现有的对商业建筑的节能研究多集中在空调系统,对围护结构的研究基本停留在定性分析的层面.为了更好地了解夏热冬暖地区商业建筑节能设计中围护结构优化设计的节能潜力和重要意义,本研究利用建筑能耗模拟软件DeST,并采用其它软件作为辅助,以广州某大型商业建筑为例,对其围护结构热工性能进行了数值模拟和分析.计算结果表明,遮阳和通风对其节能设计起到了极为重要的作用.在此基础上,对其围护结构优化设计的方向提出了建议.

  18. Solar heating and cooling of buildings (SHACOB) commercialization report: options and strategies. Part A. Volume II. Technical report. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1977-07-15

    The national and regional perspectives for SHACOB are presented. An overview is given of the participants in SHACOB commercialization. Economic, institutional, legal, and other barriers constraining commercialization are discussed. Various analytical models are examined which project the future extent of SHACOB use or market penetration and future SHACOB to US energy supplies under alternative government policies. The results for the baseline case (no further government action, of several market penetration models are presented. Possible ways to overcome each of the barriers are presented. Qualitative analyses are given for the various incentives. Each incentive is examined to assess its impact on barriers to SHACOB commercialization and its impact on various income and interest groups. Individual incentives are compared and combined into alternative policy strategies and options. (MHR)

  19. Building blocks for the development of an interface for high-throughput thin layer chromatography/ambient mass spectrometric analysis: a green methodology.

    Science.gov (United States)

    Cheng, Sy-Chyi; Huang, Min-Zong; Wu, Li-Chieh; Chou, Chih-Chiang; Cheng, Chu-Nian; Jhang, Siou-Sian; Shiea, Jentaie

    2012-07-17

    Interfacing thin layer chromatography (TLC) with ambient mass spectrometry (AMS) has been an important area of analytical chemistry because of its capability to rapidly separate and characterize the chemical compounds. In this study, we have developed a high-throughput TLC-AMS system using building blocks to deal, deliver, and collect the TLC plate through an electrospray-assisted laser desorption ionization (ELDI) source. This is the first demonstration of the use of building blocks to construct and test the TLC-MS interfacing system. With the advantages of being readily available, cheap, reusable, and extremely easy to modify without consuming any material or reagent, the use of building blocks to develop the TLC-AMS interface is undoubtedly a green methodology. The TLC plate delivery system consists of a storage box, plate dealing component, conveyer, light sensor, and plate collecting box. During a TLC-AMS analysis, the TLC plate was sent to the conveyer from a stack of TLC plates placed in the storage box. As the TLC plate passed through the ELDI source, the chemical compounds separated on the plate would be desorbed by laser desorption and subsequently postionized by electrospray ionization. The samples, including a mixture of synthetic dyes and extracts of pharmaceutical drugs, were analyzed to demonstrate the capability of this TLC-ELDI/MS system for high-throughput analysis.

  20. Guidelines for Quality Assurance Inspection of Commercial Activities Contracts for Real Property Maintenance Activities. Guide Number 7: Building Services

    Science.gov (United States)

    1993-10-01

    for leaks ( Johnson 1993). (3) Bolts, pipe hangers, stainers , or drain covers are not damaged or missing. (4) Commodes are firmly fixed and do not rock...Building Services by James H. Johnson Paul C. Bresnahan OTIC .I ••JAN 0 5 1994 A Quality Assurance (QA) Program allows the Army to evaluate and...Guide #7: Building Services AT41 SB-A5 I 6. AUTHOR(S) James H. Johnson and Paul C. Bresnahan 7. PERFORMING ORGANIZATION NAME(S) AND AODRESS(ES) 8

  1. Study on Auto-DR and Pre-Cooling of Commercial Buildings with Thermal Mass in California

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Rongxin; Xu, Peng; Piette, Mary Ann; Kiliccote, Sila

    2010-01-09

    This paper discusses how to optimize pre-cooling strategies for buildings in a hot California climate zone with the Demand Response Quick Assessment Tool (DRQAT), a building energy simulation tool. This paper outlines the procedure used to develop and calibrate DRQAT simulation models, and applies this procedure to eleven field test buildings. The results of a comparison between the measured demand savings during the peak period and the savings predicted by the simulation model indicate that the predicted demand shed match well with measured data for the corresponding auto-demand response (Auto-DR) days. The study shows that the accuracy of the simulation models is greatly improved after calibrating the initial models with measured data. These improved models can be used to predict load reductions for automated demand response events. The simulation results were compared with field test data to confirm the actual effect of demand response strategies. Results indicate that the optimal demand response strategies worked well for most of the buildings tested in this hot climate zone.

  2. Laboratory investigation of fire transfer from exterior wood decks to buildings in the wildland-urban interface

    Science.gov (United States)

    Laura E. Hasburgh; Donald S. Stone; Samuel L. Zelinka

    2017-01-01

    In the wildland-urban interface, wood decks are a target for wildfire and may be ignited by firebrands or flaming debris. Wood decks also present a potential source for ignition of structures in the wildland-urban interface. However, their role in ignition of the adjacent structure is unclear and current regulation is based in part on anecdotal evidence. This paper...

  3. Deconstruct the Seduction Clothes of Commercial Buildings House%解构商业建筑的霓裳羽衣

    Institute of Scientific and Technical Information of China (English)

    姜宣宇

    2014-01-01

    In today’s era, consumption has become a cultural symbol and symbolic consumption behavior. This article thro-ugh the rich international cases, deconstructs three kinds of common design methods of commercial construction epider-mis, and illustrates the commercial skin how to motivate the customer the visual sense experience and imagination.%当今时代,消费已成为一种符号和象征性消费的文化行为。文中通过丰富的国际案例,解构了商业建筑表皮的三种常用设计手法,并阐释了商业表皮如何激发顾客的视觉感官体验和幻想。

  4. Demonstration of Energy Savings in Commercial Buildings for Tiered Trim and Respond Method in Resetting Static Pressure for VAV Systems

    Science.gov (United States)

    2017-03-01

    damper position as an indication of system cooling load and sets a target of 90% to 95% Open for the maximum damper in the system (Point “A” to Point...building types with different DDC systems . The demonstration results are reasonable because, in theory , the TTR would save somewhat less energy than...Graphic #2 In theory , static pressure reset strategy should work if HVAC system design is done properly and system operations run as intended. All zones

  5. Green building technique application to a commercial complex%商业综合体绿色建筑技术应用研究

    Institute of Scientific and Technical Information of China (English)

    夏春海; 刘鹏

    2012-01-01

    Studies the object building which was awarded China's two-star, green building design certification. The complex involves some green building techniques such as performance simulation verification, roof greening, water permeable pavement, extract air heat recovery, natural ventilation, daylighting, CO2 gas concentration monitoring, etc. According to the characteristics of commercial complex such as large volume, multi-function and high energy consumption, proposes adopting passive energy-saving measures, designing stereoscopic landscape, optimizing HVAC system design, energy consumption monitoring.%对获得国家二星级绿色建筑设计标识认证的某商业综合体进行了研究,该项目采用了性能模拟验证、屋顶绿化、透水地面、排风热回收、自然通风、自然采光、CO2浓度监测等绿色建筑技术.针对商业综合体体量大、功能多、能耗高的特点,提出采用被动式节能措施、立体景观设计、优化空调系统设计、实施能耗监测等对策.

  6. Talking about the design concept of large-scale commercial building with Nanjing Aqua city as an example%以南京水游城为例谈大型商业建筑设计思想

    Institute of Scientific and Technical Information of China (English)

    陈卓

    2012-01-01

    针对南京水游城这个大型商业建筑项目进行了研究,分析了该项目与传统商业建筑设计理念的差别,阐述了该商业建筑整体性特点和人性化的设计原则,并总结其独特的设计手法,以期指导今后同类建筑设计。%The paper studies the large-scale commercial building project of Nanjing Aqua city, analyzes the design concept difference of the project and the traditional commercial building, describes the integrity characteristics and personal design principles of the commercial building, and summarizes its unique design tactics, with a view to guide similar building design in future.

  7. Using air-conditioning waste water and stormwater as supply management in a commercial building, case study

    Directory of Open Access Journals (Sweden)

    Celso Silva Bastos

    2013-12-01

    Full Text Available The concept of rational use as applied to water conservation consists in managing water supply and demand by trying to meet lesser quality water demands with alternative or reused water supply. This project attempts to demonstrate the application of a system that uses water drained from air conditioning system evaporators and rainwater as alternative sources. Given that each evaporator produces 4.80 liters of water per hour and considering the average use of an air conditioning system to be approximately 10 hours per day, the daily total of a single evaporator would be 48 liters. This would implicate a daily volume of 4,298 liters for the whole 137 units spread throughout the building, which in time would represent 77.72% of the daily demand of wastewater (5,53 liter/day. For the rainwater collection system, the total accumulated volume corresponds to 10% of the site area multiplied by a factor of 0.05, for a retention time of 1 hour, which will produce a total volume 14.8m³ of water. This system´s primary objective is to significantly reduce the consumption of potable water, which nowadays is used for every single activity, thus contributing to a more sustainable building and minimizing the environmental impact caused by the construction.

  8. The correlation of Acanthamoeba from the ventilation system with other environmental parameters in commercial buildings as possible indicator for indoor air quality

    Science.gov (United States)

    OOI, Soo Shen; MAK, Joon Wah; CHEN, Donald K.F.; AMBU, Stephen

    2016-01-01

    The free-living protozoan Acanthamoeba is an opportunistic pathogen that is ubiquitous in our environment. However, its role in affecting indoor air quality and ill-health of indoor occupants is relatively unknown. The present study investigated the presence of Acanthamoeba from the ventilation system and its correlation with other indoor air quality parameters, used in the industry code of practice and its potential as an indicator for indoor air quality. Indoor air quality assessments were carried out in nine commercial buildings with approval from the building management, and the parameters assessed were as recommended by the Department of Occupational Safety and Health. The presence of Acanthamoeba was determined through dust swabs from the ventilation system and indoor furniture. Logistic regression was performed to study the correlation between assessed parameters and occupants’ complaints. A total of 107 sampling points were assessed and 40.2% of the supplying air diffuser and blowing fan and 15% of the furniture were positive for cysts. There was a significant correlation between Acanthamoeba detected from the ventilation system with ambient total fungus count (r=0.327; p=0.01) and respirable particulates (r=0.276; p=0.01). Occupants’ sick building syndrome experience also correlated with the presence of Acanthamoeba in the ventilation system (r=0.361; p=0.01) and those detected on the furniture (r=0.290; p=0.01). Logistic regression showed that there was a five-fold probability of sick building syndrome among occupants when Acanthamoeba was detected in the ventilation system. PMID:27476379

  9. 商业建筑的智能化节能降耗%Using the Intelligent Technology to Realize the Energy-saving of Commercial Building

    Institute of Scientific and Technical Information of China (English)

    郭开华

    2012-01-01

    Commercial intelligent building includes the types ol olfice buildings, hotels, shopping malls etc, it combines the building automation system, office automation system and communication network system automation to realize the optimal combination of the structure, systems, services, management, to provide a safe, efficient, comfortable, convenient construction environment. It has remarkable economic benefits taking energy-saving measures on business intelligence architecture, this article mainly elaborated stages of the energy-saving measures of the building energy sources, plaiming, design, and implementation. It introduces how to use intelligent technology to realize the energy-saving and consumption reducing.%商业智能建筑包括写字楼、酒店、商场等类型,其以建筑为平台,兼备建筑设备自动化、办公自动化和通信网络系统自动化,以结构、系统、服务、管理之间的最优化组合为目的,向人们提供一个安全、高效、舒适、便利的建筑环境。实践证明,如果对商业智能建筑采取节能措施,将具有显著的经济效益。本文主要阐述了建筑能耗的来源,规划、设计、实施各阶段的节能措施,以及如何利用智能化技术来实现节能降耗。

  10. Implementation and testing of a fault detection software tool for improving control system performance in a large commercial building

    Energy Technology Data Exchange (ETDEWEB)

    Salsbury, T.I.; Diamond, R.C.

    2000-05-01

    This paper describes a model-based, feedforward control scheme that can detect faults in the controlled process and improve control performance over traditional PID control. The tool uses static simulation models of the system under control to generate feed-forward control action, which acts as a reference of correct operation. Faults that occur in the system cause discrepancies between the feedforward models and the controlled process. The scheme facilitates detection of faults by monitoring the level of these discrepancies. We present results from the first phase of tests on a dual-duct air-handling unit installed in a large office building in San Francisco. We demonstrate the ability of the tool to detect a number of preexisting faults in the system and discuss practical issues related to implementation.

  11. Effect of Heat and Electricity Storage and Reliability on Microgrid Viability: A Study of Commercial Buildings in California and New York States

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Siddiqui, Afzal; Lai, Judy; Coffey, Brian; Aki, Hirohisa

    2009-03-10

    Berkeley Lab has for several years been developing methods for selection of optimal microgrid systems, especially for commercial building applications, and applying these methods in the Distributed Energy Resources Customer Adoption Model (DER-CAM). This project began with 3 major goals: (1) to conduct detailed analysis to find the optimal equipment combination for microgrids at a few promising commercial building hosts in the two favorable markets of California and New York, (2) to extend the analysis capability of DER-CAM to include both heat and electricity storage, and (3) to make an initial effort towards adding consideration of power quality and reliability (PQR) to the capabilities of DER-CAM. All of these objectives have been pursued via analysis of the attractiveness of a Consortium for Electric Reliability Technology Solutions (CERTS) Microgrid consisting of multiple nameplate 100 kW Tecogen Premium Power Modules (CM-100). This unit consists of an asynchronous inverter-based variable speed internal combustion engine genset with combined heat and power (CHP) and power surge capability. The essence of CERTS Microgrid technology is that smarts added to the on-board power electronics of any microgrid device enables stable and safe islanded operation without the need for complex fast supervisory controls. This approach allows plug and play development of a microgrid that can potentially provide high PQR with a minimum of specialized site-specific engineering. A notable feature of the CM-100 is its time-limited surge rating of 125 kW, and DER-CAM capability to model this feature was also a necessary model enhancement.

  12. Effect of Heat and Electricity Storage and Reliability on Microgrid Viability:A Study of Commercial Buildings in California and New York States

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Siddiqui, Afzal; Lai, Judy; Coffey, Brian; Aki, Hirohisa

    2008-12-01

    In past work, Berkeley Lab has developed the Distributed Energy Resources Customer Adoption Model (DER-CAM). Given end-use energy details for a facility, a description of its economic environment and a menu of available equipment, DER-CAM finds the optimal investment portfolio and its operating schedule which together minimize the cost of meeting site service, e.g., cooling, heating, requirements. Past studies have considered combined heat and power (CHP) technologies. Methods and software have been developed to solve this problem, finding optimal solutions which take simultaneity into account. This project aims to extend on those prior capabilities in two key dimensions. In this research storage technologies have been added as well as power quality and reliability (PQR) features that provide the ability to value the additional indirect reliability benefit derived from Consortium for Electricity Reliability Technology Solutions (CERTS) Microgrid capability. This project is intended to determine how attractive on-site generation becomes to a medium-sized commercial site if economical storage (both electrical and thermal), CHP opportunities, and PQR benefits are provided in addition to avoiding electricity purchases. On-site electrical storage, generators, and the ability to seamlessly connect and disconnect from utility service would provide the facility with ride-through capability for minor grid disturbances. Three building types in both California and New York are assumed to have a share of their sensitive electrical load separable. Providing enhanced service to this load fraction has an unknown value to the facility, which is estimated analytically. In summary, this project began with 3 major goals: (1) to conduct detailed analysis to find the optimal equipment combination for microgrids at a few promising commercial building hosts in the two favorable markets of California and New York; (2) to extend the analysis capability of DER-CAM to include both heat and

  13. Particle deposition from turbulent flow: Review of published research and its applicability to ventilation ducts in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark R.; Nazaroff, William W.

    2002-06-01

    This report reviews published experimental and theoretical investigations of particle deposition from turbulent flows and considers the applicability of this body of work to the specific case of particle deposition from flows in the ducts of heating, ventilating and air conditioning (HVAC) systems. Particle deposition can detrimentally affect the performance of HVAC systems and it influences the exposure of building occupants to a variety of air pollutants. The first section of this report describes the types of HVAC systems under consideration and discusses the components, materials and operating parameters commonly found in these systems. The second section reviews published experimental investigations of particle deposition rates from turbulent flows and considers the ramifications of the experimental evidence with respect to HVAC ducts. The third section considers the structure of turbulent airflows in ventilation ducts with a particular emphasis on turbulence investigations that have been used as a basis for particle deposition models. The final section reviews published literature on predicting particle deposition rates from turbulent flows.

  14. Liquid filled prismatic louver façade for enhanced daylighting in high-rise commercial buildings.

    Science.gov (United States)

    Vlachokostas, A; Madamopoulos, N

    2015-07-27

    A liquid filled prismatic louver (LFPL) façade that can perform daylight and thermal energy harvesting with the potential to offer enhanced natural illumination levels to office spaces and thermally assist secondary thermal driven applications is proposed and analyzed. We focus the present simulation study on the evaluation of daylight enhancement in indoor space by redirecting light from a window opening to the ceiling of the room, and then-after a diffusive reflection from the ceiling-onward to the work plane of the room. Illumination simulations using LightTools, a forward ray tracing illumination simulation software, are performed for an office building space located in New York City. We show that the LFPL system achieves deeper natural light penetration, better uniformity and higher illuminance levels compared to an office space without the LFPL system. We further extend our study to a number of other representative cities in the continental US, covering different climatic zones. The LFPL system achieves good daylight harvesting performance. Finally, we discuss the potential of the LFPL system to capture solar infrared radiation heat within the liquid (e.g., water) volume and use it to assist in secondary thermal energy applications.

  15. Structure of Polystyrenesulfonate/Surfactant Mixtures at Air-Water Interfaces and Their Role as Building Blocks for Macroscopic Foam.

    Science.gov (United States)

    Schulze-Zachau, Felix; Braunschweig, Björn

    2017-04-11

    Air/water interfaces were modified by oppositely charged poly(sodium 4-styrenesulfonate) (NaPSS) and hexadecyltrimethylammonium bromide (CTAB) polyelectrolyte/surfactant mixtures and were studied on a molecular level with vibrational sum-frequency generation (SFG), tensiometry, surface dilatational rheology and ellipsometry. In order to deduce structure property relations, our results on the interfacial molecular structure and lateral interactions of PSS(-)/CTA(+) complexes were compared to the stability and structure of macroscopic foam as well as to bulk properties. For that, the CTAB concentration was fixed to 0.1 mM, while the NaPSS concentration was varied. At NaPSS monomer concentrations 0.1 mM result in a significant decrease in surface pressure and a complete loss in foamability. However, SFG and surface dilatational rheology provide strong evidence for the existence of PSS(-)/CTA(+) complexes at the interface. At polyelectrolyte concentrations >10 mM, air-water interfaces are dominated by an excess of free PSS(-) polyelectrolytes and small amounts of PSS(-)/CTA(+) complexes which, however, provide higher foam stabilities compared to CTAB free foams. The foam structure undergoes a transition from wet to polyhedral foams during the collapse.

  16. Errata, nursing homes. Budget percentiles for baseline and redesigned commercial type buildings: cities with try weather tapes; based on resource utilization factors (RUF); based on price weighting factors (PWF)

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-22

    Corrected data are presented for the P50 Redesign figure for nursing homes in the following documents in the series entitled Budget Percentiles for Baseline and Redesigned Commercial Type Buildings: For Cities with TRY Weather Tapes, Based on Price Weighing Factors (PWF), and Based on Resource Utilization Factors (RUF). (MCW)

  17. 某商业建筑地下水源热泵系统设计%The System Design of Ground Water Heat Pumps in a Commercial Building

    Institute of Scientific and Technical Information of China (English)

    高亮

    2014-01-01

    地下水源热泵是地源热泵的一种形式。与土壤源热泵比,其具有投资小、运行费用低的特点,因此在工程实际中可推广性更强。文章以某商业建筑为例,以建筑形式、面积为基础,进行了水源热泵系统设计,并对工程投资和运行费用进行了估算。%Ground water heat pump is a form of ground source heat pumps, and compare with the soil source heat pump, its investment smal and operating cost low, so it has stronger generalization in engineering practice. This article takes a commercial building as example and based on the architectural form and area, designs the water heat pump system and estimate the engineering investment and operation cost.

  18. Green Building Techniques and Cost Analysis for a Commercial Building in Foshan%佛山某商业楼绿色建筑技术及成本分析

    Institute of Scientific and Technical Information of China (English)

    廖小琴; 胡文斌

    2012-01-01

    在贯彻国家“四节一环保(节地、节能、节水、节材和环境保护)”方针基础上,以佛山某商业楼绿色设计及施工为例,结合地区气候特征,详细介绍了所采取的绿色建筑技术措施,围护结构保温、可再生资源利用、空调系统热回收以及水资源的利用情况,并具体分析了可再生资源利用、空调系统热回收以及水资源利用在本地区的技术可行性.通过对绿色技术增量成本分析,有效降低绿色建筑增量成本,取得良好的社会效益和经济效益.%To implement the ' Four Savings and One Environment Protection ' ( saving energy, saving water, saving material, saving land and one environment protection) policy promoted by the government, using a commercial building in Foshan as an example, this paper introduced in detail the green building techniques, the use of renewable resources, recovery of air conditioning system heat and utilization of water resources. Incremental cost was also performed to obtain good social and economic benefits.

  19. Technology evaluation report, commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    None,

    1976-04-01

    Criteria are presented which are to be met by solar hardware for inclusion in the demonstration program. Assessments are made, based on a survey made of solar hardware manufacturers and developers, of when components, subsystems, and systems will be available for demonstration according to the technology status categories set forth in ERDA 23A. Task outlines are provided for development activity recommended to improve available systems or develop advanced systems for later demonstration cycles. (WDM)

  20. Buildings Interoperability Landscape

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephan, Eric G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Widergren, Steven E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-12-31

    Through its Building Technologies Office (BTO), the United States Department of Energy’s Office of Energy Efficiency and Renewable Energy (DOE-EERE) is sponsoring an effort to advance interoperability for the integration of intelligent buildings equipment and automation systems, understanding the importance of integration frameworks and product ecosystems to this cause. This is important to BTO’s mission to enhance energy efficiency and save energy for economic and environmental purposes. For connected buildings ecosystems of products and services from various manufacturers to flourish, the ICT aspects of the equipment need to integrate and operate simply and reliably. Within the concepts of interoperability lie the specification, development, and certification of equipment with standards-based interfaces that connect and work. Beyond this, a healthy community of stakeholders that contribute to and use interoperability work products must be developed. On May 1, 2014, the DOE convened a technical meeting to take stock of the current state of interoperability of connected equipment and systems in buildings. Several insights from that meeting helped facilitate a draft description of the landscape of interoperability for connected buildings, which focuses mainly on small and medium commercial buildings. This document revises the February 2015 landscape document to address reviewer comments, incorporate important insights from the Buildings Interoperability Vision technical meeting, and capture thoughts from that meeting about the topics to be addressed in a buildings interoperability vision. In particular, greater attention is paid to the state of information modeling in buildings and the great potential for near-term benefits in this area from progress and community alignment.

  1. Interfacing with the WEB

    CERN Document Server

    Dönszelmann, M

    1995-01-01

    Interfacing to the Web or programming interfaces for the Web is used to provide dynamic information for Web users. Using the Web as a transport system of information poses three constraints: namespace, statelessness and performance. To build interfaces on either server or client side of the Web one has to meet these constraints. Several examples, currently in use in High Energy Physics Experiments are described. They range from an interface to show where buildings are located to an interface showing active values of the On-line System of the DELPHI (CERN)..

  2. Surface tectonics of nanoporous networks of melamine-capped molecular building blocks formed through interface Schiff-base reactions.

    Science.gov (United States)

    Liu, Xuan-He; Wang, Dong; Wan, Li-Jun

    2013-10-01

    Control over the assembly of molecules on a surface is of great importance for the fabrication of molecule-based miniature devices. Melamine (MA) and molecules with terminal MA units are promising candidates for supramolecular interfacial packing patterning, owing to their multiple hydrogen-bonding sites. Herein, we report the formation of self-assembled structures of MA-capped molecules through a simple on-surface synthetic route. MA terminal groups were successfully fabricated onto rigid molecular cores with 2-fold and 3-fold symmetry through interfacial Schiff-base reactions between MA and aldehyde groups. Sub-molecular scanning tunneling microscopy (STM) imaging of the resultant adlayer revealed the formation of nanoporous networks. Detailed structural analysis indicated that strong hydrogen-bonding interactions between the MA groups persistently drove the formation of nanoporous networks. Herein, we demonstrate that functional groups with strong hydrogen-bond-formation ability are promising building blocks for the guided assembly of nanoporous networks and other hierarchical 2D assemblies. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Development of valence-directed nanoparticle building blocks on the basis of controlled bio/nano-interfacing chemistry

    Science.gov (United States)

    Kim, Jeong-Hwan

    The assembly of nanoparticles in controllable and predictable ways would not only aid practical nanoscale assembly, which requires accurate and scalable assembly of large and complex nanoscale structures, but also would increase their utility for many applications, including electronics, optics, sensing and imaging, medical diagnostics, etc. Well-defined and controlled functionality and directionality of the building blocks are essential to actively control the molecular assembly processes at the nanometer scale. Such controls over the functionality and directionality would enable us to construct sophisticated nanostructures to take advantage of the increasing number of available nanocomponents and ultimately to approximate the complexity and the functionality of current microfabrication. We have developed a serial solid-phase placement approach to synthesize anisotropically or symmetrically functionalized gold nanoparticles (AuNPs), in which the functionality and directionality (e.g., numbers, locations, and orientations) of the functional ligands are controlled. Two types of bi-functionalized (bif-) AuNPs were synthesized at a site-specific manner with increased yield and accuracy: (1) homo-bif-AuNPs with two carboxyl groups at ˜180° angle (para-configuration) and (2) hetero-bif-AuNPs with one carboxyl and one amine functional groups at less than 180°, but greater than 90° angle (meta-configuration). With such control, we successfully demonstrated the assembly of intentionally designed one-dimensional (1D) chains with homo-bif-AuNPs and two-dimensional (2D) rings with hetero-bif-AuNPs, confirming the high functional as well as directional selectivity of the functionalized NPs. This study represents an important step towards accurate, reliable, and scaled-up manufacturing of complex nanoscale structures, potentially making 'bottom-up' nanofabrication of practical use. We have further developed the ligand replacement technology to achieve such active controls

  4. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading

    NARCIS (Netherlands)

    Ccahuana Vasqueza, Vanessa Zulema; Ozcan, Mutlu; Kimpara, Estevao Tomomitsu

    2009-01-01

    Objectives. This study evaluated the effect of thermal- and mechanical-cycling on the shear bond strength of three low-fusing glassy matrix dental ceramics to commercial pure titanium (cpTi) when compared to conventional feldspathic ceramic fused to gold alloy. Methods. Metallic frameworks (diameter

  5. Trki ptic v stekleno pročelje poslovne stavbe v Ljubljani (osrednja Slovenija jeseni 2012/ Bird collisions with glass façade of a commercial building in Ljubljana (central Slovenia in autumn 2012

    Directory of Open Access Journals (Sweden)

    Šumrada Tanja

    2015-11-01

    Full Text Available From 28 Sep to 7 Oct 2012, bird collisions with the glass façade of a commercial building in the centre of Ljubljana were monitored. The observations lasted 45-60 minutes in the morning (7.00-10.00 hrs, around midday (11.00-14.00 hrs and in the afternoon (15.00-18.00 hrs. Behaviour of all birds and scavengers, which could potentially be looking for bird carcasses in the vicinity of the building, was noted. In 27.25 hours of observation, 16 collisions (3 resulting in death, 13 cases with birds flying away seemingly unharmed and 19 near collisions, when birds avoided the building at the last moment before collision, were recorded. The total collision rate was 0.59 collisions per hour of observation. All birds that collided with the building, except Feral Pigeon Columba livia f. domestica, were passerines, among which tits Paridae predominated (62.5% of birds that collided with the building. The glass façade functioned as a mirror, reflecting tree crowns from across the street. Data show that most collisions occurred in the middle part of the building during the morning. Among potential scavengers, domestic cat Felis domesticus and Hooded Crow Corvus cornix were observed. The latter regularly flew around the building during the observation period, possibly looking for bird carcasses.

  6. Marketing mix - commercial gas

    Energy Technology Data Exchange (ETDEWEB)

    Ford, M.F.

    1975-07-01

    British Gas Corp. points out that a substantial increase in the use of gas in Great Britain's commercial energy market has occurred in the past 6 yr. Some of the newest applications of gas are in the areas of the cook/freeze system of preparing frozen foods in commercial catering, commissariats preparing in-flight food, and heating/cooling systems of large buildings. The variety of buildings and institutions using gas-fired systems indicates that, with the sensible pricing policies and the security of an indigenous fuel, the commercial market for gas will continue to develop for several years in Britain.

  7. 商业建筑的整体空间规划设计与人流动线设计%Design of the Overall Space Planning and Passengers Flow line of Commercial Buildings

    Institute of Scientific and Technical Information of China (English)

    黄明星

    2013-01-01

    Thesuccess and failure of Commercial building depends primarily on commercial building’s degree of attracting, in other words, whether it can attract people and stimulate people's consumption desire is quite important. Planning the commercial building overall space, using a line organization reasonably ,creating personalized shopping environment, and control ing the consumer shopping psychology accurately is the key to create and enhance business value. In order to discuss this theme, Shanghai ZhongyeXiangtengCity Square design as an example. This paper combines with the key points of commercial construction overal plan and passenger lfow line system planning and design to research and guide the design of commercial buildings.We wil do our best and be committed to create the maximize business value of the shopping center.%  商业建筑的成与败主要取决于商业建筑自身对人的吸引程度,即是否能留住人、是否能刺激人的消费欲望。通过商业建筑的整体空间规划、合理的动线组织,营造人性化的购物环境、准确把控消费者的购物心理,是创造并提升商业价值的关键。文章结合上海中冶祥腾城市广场设计实例,结合商业建筑的整体规划与人流动线系统规划设计关键点的研究分析,来指导商业建筑的方案设计,以期最大限度的创造购物中心的商业价值。

  8. Academic Institutions and One Health: Building Capacity for Transdisciplinary Research Approaches to Address Complex Health Issues at the Animal-Human-Ecosystem Interface.

    Science.gov (United States)

    Allen-Scott, Lisa K; Buntain, Bonnie; Hatfield, Jennifer M; Meisser, Andrea; Thomas, Christopher James

    2015-07-01

    To improve health at the human, animal, and ecosystem interface, defined as One Health, training of researchers must transcend individual disciplines to develop a new process of collaboration. The transdisciplinary research approach integrates frameworks and methodologies beyond academic disciplines and includes involvement of and input from policy makers and members of the community. The authors argue that there should be a significant shift in academic institutions' research capacity to achieve the added value of a transdisciplinary approach for addressing One Health problems. This Perspective is a call to action for academic institutions to provide the foundations for this salient shift. The authors begin by describing the transdisciplinary approach, propose methods for building transdisciplinary research capacity, and highlight three value propositions that support the case. Examples are provided to illustrate how the transdisciplinary approach to research adds value through improved sustainability of impact, increased cost-effectiveness, and enhanced abilities to mitigate potentially harmful unintended consequences. The authors conclude with three key recommendations for academic institutions: (1) a focus on creating enabling environments for One Health and transdisciplinary research, (2) the development of novel funding structures for transdisciplinary research, and (3) training of "transmitters" using real-world-oriented educational programs that break down research silos through collaboration across disciplines.

  9. Academic Institutions and One Health: Building Capacity for Transdisciplinary Research Approaches to Address Complex Health Issues at the Animal–Human–Ecosystem Interface

    Science.gov (United States)

    Allen-Scott, Lisa K.; Buntain, Bonnie; Hatfield, Jennifer M.; Meisser, Andrea

    2015-01-01

    To improve health at the human, animal, and ecosystem interface, defined as One Health, training of researchers must transcend individual disciplines to develop a new process of collaboration. The transdisciplinary research approach integrates frameworks and methodologies beyond academic disciplines and includes involvement of and input from policy makers and members of the community. The authors argue that there should be a significant shift in academic institutions’ research capacity to achieve the added value of a transdisciplinary approach for addressing One Health problems. This Perspective is a call to action for academic institutions to provide the foundations for this salient shift. The authors begin by describing the transdisciplinary approach, propose methods for building transdisciplinary research capacity, and highlight three value propositions that support the case. Examples are provided to illustrate how the transdisciplinary approach to research adds value through improved sustainability of impact, increased cost-effectiveness, and enhanced abilities to mitigate potentially harmful unintended consequences. The authors conclude with three key recommendations for academic institutions: (1) a focus on creating enabling environments for One Health and transdisciplinary research, (2) the development of novel funding structures for transdisciplinary research, and (3) training of “transmitters” using real-world-oriented educational programs that break down research silos through collaboration across disciplines. PMID:25650827

  10. The financial feasible electric energy conservation potential in brazilian public and commercial buildings - retrofit demonstrations; O potencial de conservacao de energia eletrica financeiramente viavel em edificios publicos e comerciais do Brasil: demonstracoes de retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lomardon, Louise Land B. [Universidade Federal Fluminense, Niteroi, RJ (Brazil); Lamberts, Roberto [Santa Catarina Univ., Florianopolis, SC (Brazil); Thome, Mabele [ELETROBRAS, Rio de Janeiro, RJ (Brazil). PROCEL

    1998-12-31

    In order to help the development of energy efficiency building standard in Brazil, to demonstrate state of art technologies and to encourage the use of hourly energy simulation tools, the National Energy Conservation Program (PROCEL) has started the 6 Cities Project. The project is being developed in six cities around the country. For this project a standard methodology was developed and applied. The methodology consists of a survey in the local utilities to establish the highest energy consumers in the commercial and public sector. A data-base is being created with information on energy consumption intensity and demand intensity in 15 buildings in each city. The data-base was designed to help the standards development. Among those buildings, in each city, two were selected, one is a public building and the other a private building, for a detailed energy audit. The audit data was used to calibrate a DOE2 simulation model. Simulations were performed and state of art technologies for energy efficiency are being tested and will be implemented. An after retrofit monitoring program is planed. In this paper the results of the first buildings will be showed, whose results point for reductions of electricity consumption, financially viable, between 25% and 35%. (author) 8 refs., 9 figs., 4 tabs.; e-mail: louise at ppe.ufrj.br; lamberts at ecv.ufsc.br

  11. Building the Commercial Education Professional Competency Profile Construyendo el perfil por competencias para el profesional en Educación Comercial

    Directory of Open Access Journals (Sweden)

    Isabel Araya Muñoz

    2012-11-01

    Full Text Available

    This paper provides a complete description of the Commercial Education Professional Competency Profile that resulted from the curricular diagnosis of the Licenciatura en Educación Comercial , at the Universidad Nacional, Costa Rica.  The methodological strategy used relies on the principles of research on education. Upon expert validation, written questionnaires were applied to first-year students, students of the licenciatura, practicing professionals and employers. The objective was to describe a particular education situation. Data was analyzed according to two categories: intentions/principles and scope/development. The findings resulted in the characteristics of the Commercial Education professionals, i.e. characteristics related to the discipline, characteristics related to the administrative management of teaching, specific and general characteristics of education and pedagogy, and characteristics associated to human development. Based on those criteria, on the curricular requirements of the information sources and on the curricular perspectives of the Academic Unit, ideas were put into practice to build the competency profile. The ideas proposed comprise the curricular fundamentals of the educational project on which the profile is set out, which include the subject of the study program, the global competency or training goal, the generic competencies as cross-cutting approaches, as well as the –pedagogical and disciplinary− specific competencies. The specific competencies of the discipline are focused on four competency areas: document production, organizational support, technological resources and information management.

    (1 Translator’s Note: One-year post-Bachelor study program in Commercial Education.

    Recibido 01 de marzo de 2012 • Corregido 09 de octubre de 2012 • Aceptado 07 de noviembre de 2012

    Este trabajo detalla las competencias del perfil por competencias para el profesional en Educaci

  12. Weighting Factors for the Commercial Building Prototypes Used in the Development of ANSI/ASHRAE/IESNA Standard 90.1-2010

    Energy Technology Data Exchange (ETDEWEB)

    Jarnagin, Ronald E.; Bandyopadhyay, Gopal K.

    2010-01-21

    Detailed construction data from the McGraw Hill Construction Database was used to develop construction weights by climate zones for use with DOE Benchmark Buildings and for the ASHRAE Standard 90.1-2010 development. These construction weights were applied to energy savings estimates from simulation of the benchmark buildings to establish weighted national energy savings.

  13. Approach for Estimating Exposures and Incremental Health Effects from Lead During Renovation, Repair, and Painting Activities in Public and Commercial Buildings

    Science.gov (United States)

    Approach for Estimating Exposures and Incremental Health Effects from Lead During Renovation, Repair, and Painting Activities in Public and Commercial Buildings” (Technical Approach Document). Also available for public review and comment are two supplementary documents: the detai...

  14. 沿街商业建筑立面广告位的改造设计思考%Modification design of the advertisement on the commercial building facade along the road

    Institute of Scientific and Technical Information of China (English)

    席文川; 杨彩虹; 王旭彤; 石丽丽

    2011-01-01

    The advertisement on the commercial buildings along the mad was designed to overcome the common problems such as the disorder, the diversified forms, the various meterials from the following 4 aspects: the integration, the unity, submissiveness and instructive, taking the reconstruction project of the commercial building facade in Qianjing avenue of Handan. The disorderly commercial advertisements were uniformed by unifying the size and regulating the design. The elements of the commercial advertisements was ordered, organized and rationalized to integrate into the existing design of commercial building facade.The dominant building facade should be protected and the subordinate removed. The existing shop sign was redesign by advertising project and installation design to cohere with the style of the whole street.%针对沿街建筑立面改造中的商业广告位存在的杂乱、种类繁多、材质不一等问题,以邯郸市前进大街沿街商业建筑立面改造工程为例,依据相关城市法规条例从整体性、统一性、主从性、控制引导性等4个方面对商业建筑广告位进行改造设计.通过统一尺寸、规范设计,对街区内无序设置的商业广告位的整合;将广告位的元素秩序化、组织化、合理化地融入既有建筑立面的设计中;保护主要的建筑立面,拆除次要的广告位;通过广告位设计将一些商家原本定型的店铺招牌以规划设计手段进行控制,并引导其进行广告安装设计,以满足整条街区风格协调的目的.

  15. Hawaii demand-side management resource assessment. Final report, Reference Volume 2: Final residential and commercial building prototypes and DOE-2.1E developed UECs and EUIs; Part 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    This section contains the detailed measured impact results and market segment data for each DSM case examined for this building type. A complete index of all base and measure cases defined for this building type is shown first. This index represents an expansion of the base and measure matrix presented in Table 1 (residential) or Table 2 (commercial) for the applicable sector. Following this index, a summary report sheet is provided for each DSM measure case in the order shown in the index. The summary report sheet contains a host of information and selected graphs which define and depict the measure impacts and outline the market segment data assumptions utilized for each case in the DBEDT DSM Forecasting models. The variables and figures included in the summary report sheet are described. Numerous tables and figures are included.

  16. Internet Financial Innovation and Brand Building Model of Commercial Banks%互联网金融创新与商业银行品牌塑造模式

    Institute of Scientific and Technical Information of China (English)

    谢治春

    2016-01-01

    With the influence of Internet banking,commercial banks’ digital and network transformation would bear upon the better service ability for economy and inclusive finance promotion. In this process of transformation, brand management has become an important part. Should commercial banks have a new model to adapt to digital and network transformation? We believe that the Internet has a direct impact on commercial banks brand foundation. At first, this paper analyzes Internet financial innovation how to shape the brand foundation. It is proved that products or services provider, product or service users, information exchange, product and service delivery channels are the four contents of brand foundation. Then, it puts forward a new brand building model -Co-construction brand building model, and discusses how to build the new brand model of commercial banks.%在互联网金融影响下,商业银行的数字化和网络化转型与服务实体经济及推广普惠金融有重要关系。在这个转型过程中,品牌管理成为重要内容。商业银行是否应该有一种新的品牌塑造模式来适应数字化和网络化转型?我们认为,互联网金融创新直接影响了商业银行品牌塑造基础。本文首先分析了互联网金融创新对品牌塑造基础的影响,认为品牌塑造基础由产品和服务的提供者、产品和服务的使用者、信息交换方式、产品和服务交付渠道等四个方面构成。接着,作者提出了一种新的品牌塑造模式———共建式品牌塑造模式,并对商业银行如何实施共建式品牌塑造模式进行了讨论。

  17. Study on livability in the landscape design of commercial buildings%融入宜居性的景观设计在商业建筑中的应用研究

    Institute of Scientific and Technical Information of China (English)

    赵光玲

    2015-01-01

    随着城市生活节奏的加快,人们工作压力的加大,在进行商业建筑景观设计时,宜居性越来越成为重要的考虑因素。本文从宜居性的概念出发,提出了在商业建筑景观设计中,宜居性的架构和表达,即贯穿以人为本;健全生态绿化设计观念;尊重人的私密性和社会性;适应使用者消费心理;树立绿色发展理念。并以上海市杨浦区海上海商业街的景观设计为研究对象,阐述商业建筑景观设计的宜居特性表现,以期提出科学的参考依据,使其能在城市环境景观系统的开发中发挥出更大的作用。%With the city to accelerate the pace of life, increasing work pressure, in the landscape design of commercial building, livability has become a more and more important role. In this paper, from the concept of livability, and the expression of the livability of architecture in the landscape design of commercial building is presented, to perfect the ecological greening, respect people's privacy and social adaptation and consumer psychology of the users, and establish the concept of green development. Lastly, the performance characteristics of the commercial building livable landscape design is described in the landscape design of Haishanghai commercial street in Yangpu district Shanghai, and it can be concluded that livability play a greater role in the development of the urban environment and landscape in the landscape design.

  18. Evaluation of energy savings related to building envelope retrofit techniques and ventilation strategies for low energy cooling in offices and commercial sector

    OpenAIRE

    Grignon-Massé, Laurent; Marchio, Dominique; Pietrobon, Marco; Pagliano, Lorenzo

    2010-01-01

    International audience; The energy savings achievable in the end-use space cooling depend on a number of variables related to the building envelope, the plants and to some extent the behavior of occupants. They are hence complex to evaluate and consequently often underrepresented in designers, energy managers and policy makers decisions.This paper is based on some results of the European Commission supported project KeepCool2. It discusses a methodology for bottom-up assessment of the energy ...

  19. Research on Influence of Commercial Features Factor on Decision of Building Energy Conservation Scheme%商务特征指标对建筑节能方案决策的影响研究

    Institute of Scientific and Technical Information of China (English)

    薛汝才; 杨红昌; 柴保双; 邱枫

    2016-01-01

    Decision of building energy conservation scheme is a complicated and integrated process with numerous of indices,and there is no mature theoretical evaluation system or decision method so far. Based on the establishment of evaluation system covering technical and economical feature indexes,the paper introduces commercial feature indexes of policies and regulations risk,business contract risk,project operation cycle,business opportunity cost. Then,takes an electric power dispatching center as an example,builds a comprehensive optimized decision model considering "technology + economy + business" features from the feasibility schemes with CRITIC method,verifies the influence of commercial features factor on the decision of building energy saving conservation scheme,provides reference for the relevant enterprises to carry out decision from feasible investment schemes for energy saving.%建筑节能方案决策是一个复杂的多项指标综合分析过程,尚未形成成熟的决策方法或理论体系.在构建涵盖技术特征、经济特征评价指标体系的基础上,引入政策法规风险、商务合同风险、项目运作周期、商务机会成本等商务特征指标,以某项目为例,采用CRITIC客观权重赋权方法,构建"技术+经济+商务"特征的可行性方案综合优选决策模型,验证商务特征指标对建筑节能改造方案决策的影响,为相关企业进行节能改造可行性投资方案选择提供参考.

  20. Plan of Using Modern Agriculture High-New Information Technology for Building Stable Nation Commercial Grain and Green Agriculture Base of China

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The North-East China is nation commercial grain base of China. It provides important grain supply for other areas of the country every year. The nation and modern farmers are looking for advanced technological solutions to increase production and preserve environment. Considering of this aim,this paper introduce a new planning that using 3S technology to develop precision farming, explaining its technology frame, operation steps and advantages. On the other hand,this paper also introduce the concept of precision farming and discusses the role of 3S technology as a data collection,management and analysis tool.

  1. Product and market study for Los Alamos National Laboratory. Building resources for technology commercialization: The SciBus Analytical, Inc. paradigm

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    The study project was undertaken to investigate how entrepreneurial small businesses with technology licenses can develop product and market strategies sufficiently persuasive to attract resources and exploit commercialization opportunities. The study attempts to answer two primary questions: (1) What key business development strategies are likely to make technology transfers successful, and (2) How should the plan best be presented in order to attract resources (e.g., personnel, funding, channels of distribution)? In the opinion of the investigator, Calidex Corporation, if the business strategies later prove to be successful, then the plan model has relevance for any technology licensee attempting to accumulate resources and bridge from technology resident in government laboratories to the commercial marketplace. The study utilized SciBus Analytical, Inc. (SciBus), a Los Alamos National Laboratory CRADA participant, as the paradigm small business technology licensee. The investigator concluded that the optimum value of the study lay in the preparation of an actual business development plan for SciBus that might then have, hopefully, broader relevance and merit for other private sector technology transfer licensees working with various Government agencies.

  2. The Java Legacy Interface

    DEFF Research Database (Denmark)

    Korsholm, Stephan

    2007-01-01

    The Java Legacy Interface is designed to use Java for encapsulating native legacy code on small embedded platforms. We discuss why existing technologies for encapsulating legacy code (JNI) is not sufficient for an important range of small embedded platforms, and we show how the Java Legacy...... Interface offers this previously missing functionality. We describe an implementation of the Java Legacy Interface for a particular virtual machine, and how we have used this virtual machine to integrate Java with an existing, commercial, soft real-time, C/C++ legacy platform....

  3. The Java Legacy Interface

    DEFF Research Database (Denmark)

    Korsholm, Stephan

    2007-01-01

    The Java Legacy Interface is designed to use Java for encapsulating native legacy code on small embedded platforms. We discuss why existing technologies for encapsulating legacy code (JNI) is not sufficient for an important range of small embedded platforms, and we show how the Java Legacy...... Interface offers this previously missing functionality. We describe an implementation of the Java Legacy Interface for a particular virtual machine, and how we have used this virtual machine to integrate Java with an existing, commercial, soft real-time, C/C++ legacy platform....

  4. Buildings interoperability landscape - Draft

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Dave B. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Stephan, Eric G. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Widergren, Steven E. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

    2015-02-01

    Buildings are an integral part of our nation’s energy economy. The advancement in information and communications technology (ICT) has revolutionized energy management in industrial facilities and large commercial buildings. As ICT costs decrease and capabilities increase, buildings automation and energy management features are transforming the small-medium commercial and residential buildings sectors. A vision of a connected world in which equipment and systems within buildings coordinate with each other to efficiently meet their owners’ and occupants’ needs, and where buildings regularly transact business with other buildings and service providers (such as gas and electric service providers) is emerging. However, while the technology to support this collaboration has been demonstrated at various degrees of maturity, the integration frameworks and ecosystems of products that support the ability to easily install, maintain, and evolve building systems and their equipment components are struggling to nurture the fledging business propositions of their proponents.

  5. Kinetic Interface

    DEFF Research Database (Denmark)

    2009-01-01

    A kinetic interface for orientation detection in a video training system is disclosed. The interface includes a balance platform instrumented with inertial motion sensors. The interface engages a participant's sense of balance in training exercises.......A kinetic interface for orientation detection in a video training system is disclosed. The interface includes a balance platform instrumented with inertial motion sensors. The interface engages a participant's sense of balance in training exercises....

  6. 三坊七巷古建筑改建商用场所消防安全分析%Fire safety analysis of reconstructing the Sanfangqixiang historica buildings into commercial buildings

    Institute of Scientific and Technical Information of China (English)

    张琳; 陈秉安

    2013-01-01

    利用FDS和Building EXODUS软件实例分析了某三坊七巷历史文化街区古建筑中改建的某商用场所(聚春园驿馆)的消防安全性能,模拟烟气运动过程得到人员可用安全疏散时间,模拟人员运动疏散过程得到人员必需疏散时间,验证场所的消防安全性,并提出类似场所消防管理的改进建议,对类似场所的消防审批和监管提供参考.

  7. 上海某商务办公楼暖通空调绿色、低碳设计%Green Low-Carbon HVAC Design of a Commercial Office Building in Shanghai

    Institute of Scientific and Technical Information of China (English)

    吴玉涛

    2016-01-01

    结合上海某商务办公楼绿色、低碳设计实例,阐述了暖通空调节能新技术的系统设计思路,并对设计方法、设计难点进行重点分析和总结,为同类工程设计提供借鉴。设计综合采用了高性能围护结构保温系统、地源热泵系统、温湿独立控制系统、末端辐射系统、热泵热水系统等一系列节能措施。%Combined with green low carbon design examples of a commercial office building in Shanghai, this paper expounds the system design ideas of new energy saving technology. The design method and design difficulty are analyzed and summarized, which can provide reference for similar engineering pro-ject. The HVAC systems include high-performance insulation system of building envelope, soil source heat pump system, temperature and humidity independent control system, roof radiation system, heat pump hot water system, etc.

  8. Building Energy Management Open Source Software

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Saifur [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States)

    2017-08-25

    Funded by the U.S. Department of Energy in November 2013, a Building Energy Management Open Source Software (BEMOSS) platform was engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. According to the Energy Information Administration (EIA), small- (5,000 square feet or smaller) and medium-sized (between 5,001 to 50,000 square feet) commercial buildings constitute about 95% of all commercial buildings in the U.S. These buildings typically do not have Building Automation Systems (BAS) to monitor and control building operation. While commercial BAS solutions exist, including those from Siemens, Honeywell, Johnsons Controls and many more, they are not cost effective in the context of small- and medium-sized commercial buildings, and typically work with specific controller products from the same company. BEMOSS targets small and medium-sized commercial buildings to address this gap.

  9. Sand-lime bricks in commercial and industrial buildings: Optimum sound and heat insulation. Increasing requirements on sound and heat insulation in commercial and industrial buildings; Kalksandstein im Gewerbe- und Industriebau: optimaler Schallschutz und hoher Waermeschutz. Schallschutz- und waermetechnische Gesichtspunkte gewinnen im Gewerbe- und Industriebau immer mehr an Bedeutung

    Energy Technology Data Exchange (ETDEWEB)

    Niebuhr, B.

    1998-01-01

    The contribution shows how sound and heat insulation can be optimized, using real buildings constructed of sand-lime bricks as examples. (GL) [Deutsch] Wie zukunftsbewusst denkende und handelnde Unternehmer optimalen Schall- und Waermeschutz unter einen Hut bringen koennen, wird an konkreten Baukonstruktionen mit dem Wandbaustoff Kalksandstein praxisgerecht verdeutlicht. (GL)

  10. Space Commercialization

    Science.gov (United States)

    Martin, Gary L.

    2011-01-01

    A robust and competitive commercial space sector is vital to continued progress in space. The United States is committed to encouraging and facilitating the growth of a U.S. commercial space sector that supports U.S. needs, is globally competitive, and advances U.S. leadership in the generation of new markets and innovation-driven entrepreneurship. Energize competitive domestic industries to participate in global markets and advance the development of: satellite manufacturing; satellite-based services; space launch; terrestrial applications; and increased entrepreneurship. Purchase and use commercial space capabilities and services to the maximum practical extent Actively explore the use of inventive, nontraditional arrangements for acquiring commercial space goods and services to meet United States Government requirements, including measures such as public-private partnerships, . Refrain from conducting United States Government space activities that preclude, discourage, or compete with U.S. commercial space activities. Pursue potential opportunities for transferring routine, operational space functions to the commercial space sector where beneficial and cost-effective.

  11. Planning and Operation of Commercial Application Center

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Yeon; Kim, Kye Ryung; Lee, Tae Joon; Lee, Jae Hyeong; Park, Je Won; Lee, Jae Sang

    2003-06-15

    The objectives of this R and D project are as follows : First, transferring developed technologies to outside companies and operating technology market to vitalize technology transactions, Second, developing commercial application projects to transfer technologies for commercial purposes and to solve interface problems in commercial applications, Third, enhancing commercial utilizations of developed accelerator and beam utilization technologies, Finally. preparing infra-structures for the development of over 30 venture- businesses based on achieved technologies through the Proton Engineering Frontier Project.

  12. Estimated potential of energy saving and reduction of the demand commercial buildings illumination; Potencial estimado de ahorro de energia y reduccion de la demanda en iluminacion de edificios comerciales

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Gomez, Victor Hugo; Morillon Galvez, David [Posgrado en Energetica de la DEPFI-UNAM, Mexico, D. F. (Mexico)

    1999-07-01

    In this paper the estimated energy saving potential in illumination, the energy end use and the technology used in commercial buildings of different use is analyzed. Estimation that departs from information of the Fideicomiso para el Ahorro de Energia (FIDE) demonstrative cases, presents the energy saving and the demand reduction in a sample of 29 buildings, among which are shopping malls, hospitals, schools, hotels, restaurants and public buildings in which energy saving programs have been carried out, with measures such as the cleaning of the luminaries and its replacement for more efficient ones. The average saving obtained is of 21.81%, in the following areas: illumination, air conditioning and others. In addition, in a sample of 4 buildings, it was observed that before applying the energy saving programs, two of them did not fulfill with the norm NOM-007-1995 (electric power density in interior lighting systems W/m{sup 2}) and later did fulfill the values and criteria of the norm. [Spanish] En el presente trabajo se analiza el potencial estimado de ahorro de energia en iluminacion, el uso final de la energia y la tecnologia empleada en edificios comerciales de uso distinto. Estimacion que parte de la informacion de los casos demostrativos del Fideicomiso para el Ahorro de Energia (FIDE), se presenta el ahorro y reduccion de la demanda en una muestra de 29 edificios, entre los que se tienen centros comerciales, hospitales, escuelas, hoteles, restaurantes y edificios publicos en los cuales se ha llevado a cabo programas de ahorro de energia, con medidas como la limpieza de las luminarias y su remplazo por otros mas eficientes. El ahorro promedio obtenido es de 21.81%, en las siguientes areas: iluminacion, aire acondicionado y otros. Ademas, en una muestra de 4 edificios, se observo que antes de aplicar los programas de ahorro de energia, dos no cumplian con la norma NOM-007-ENER-1995 (densidad de potencia electrica en alumbrado interior W/m{sup 2}) y

  13. Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Apte, Mike G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-10-31

    This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These

  14. Interface Consistency

    DEFF Research Database (Denmark)

    Staunstrup, Jørgen

    1998-01-01

    This paper proposes that Interface Consistency is an important issue for the development of modular designs. Byproviding a precise specification of component interfaces it becomes possible to check that separately developedcomponents use a common interface in a coherent matter thus avoiding a very...... significant source of design errors. Awide range of interface specifications are possible, the simplest form is a syntactical check of parameter types.However, today it is possible to do more sophisticated forms involving semantic checks....

  15. 体验营销模式下历史性商业建筑改造设计研究%STUDY ON TRANSFORMATION DESIGN FOR HISTORIC COMMERCIAL BUILDINGS UNDER EXPERIENCE MARKETING MODE

    Institute of Scientific and Technical Information of China (English)

    陈菲; 林建群; 付伟庆

    2012-01-01

    本文基于体验经济和体验营销的相关理论,分析体验营销模式在哈尔滨秋林公司环境改造中的作用.提出改造设计所应遵循的三个主要原则.据此对秋林老店地下一层需要改造的重要元素进行分析,制定体验情境改造设计方案.以进一步对历史性商业建筑营销环境的改造方法进行探索%Based on some theories of experience economy and experience marketing, this paper analysis the roles of experience marketing model in transformation design of Qiulin old store environment. The paper also proposes three important principles which the transformation design needs to be followed: import principle, protection and renewal principle, and reflect principle. Accordingly the three principles, the paper analysis some important elements in transformation design of basement of Qiulin old store, and brings experience situational transformation design and introductions. The design explores a new solution for marketing environment transformation of our historic commercial building.

  16. 一种用于图形设备接口的笔画模型方法%A Method Named Stroke Modeling for Building Graphics Device Interface

    Institute of Scientific and Technical Information of China (English)

    黄东运; 雷欢; 卢杏坚

    2012-01-01

      When the live video surveillance system interacts with users, it needs fast implementation for drawing or painting user controls, interested region picks, activity marks as well as digital images to avoid a frozen display, that requires the graphics device interface modules to draw or paint quickly. We propose a new method named stroke modeling, which takes the advantages of drawing primitives provided by DirectX to transform drawing tasks into stroke objects, enabling the video systems in its run time to fulfill a fast implementation for render or display by submitting the pre-generated stoke objects to the DirectX, cutting off the drawing time dramatically. Following the method, we have developed a graphics device interface module which may be used for quick graphical rendering or drawing.%  视频监控的在屏交互过程中,需要快速地对交互控件、感兴趣区域、活动标记等图形和图像进行绘制,为避免画面的停滞感,要求图形设备接口能快速进行绘制。为此,提出了一种笔画模型方法。利用 DirectX的原始绘制能力,该方法将绘制任务转换成笔画对象,使视频系统在实时运行过程中,只需将已转换的笔画对象的绘制数据提交给 DirectX 进行渲染和显示即可,降低重复绘制时间,满足系统的快速绘制要求。基于笔画模型方法,开发了一种可快速绘制的图形设备接口。

  17. Interface models

    DEFF Research Database (Denmark)

    Ravn, Anders P.; Staunstrup, Jørgen

    1994-01-01

    This paper proposes a model for specifying interfaces between concurrently executing modules of a computing system. The model does not prescribe a particular type of communication protocol and is aimed at describing interfaces between both software and hardware modules or a combination of the two....... The model describes both functional and timing properties of an interface...

  18. Ventilation in Commercial and Residential Buildings

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    A number of areas have to be considered in connection with indoor air quality and ventilation. The selection of ventilation principle and components in the ventilation system will have influence on the indoor air quality and this subject will be discussed on the following pages. The main object o...

  19. Commercial Building Motor Protection Response Report

    Energy Technology Data Exchange (ETDEWEB)

    James, Daniel P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kueck, John [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-06-17

    When voltages recover, motors may immediately reenergize and reaccelerate, or delay for a few minutes, or stay stalled. The estimated motor response is given for both the voltage sag magnitude and voltage sag duration. These response estimates are based on experience and available test data. Good data is available for voltage sag response for many components such as relays and contactors, but little data is available for both voltage sag and recovery response. The tables in Appendix A include data from recent voltage sag and recovery tests performed by SCE and BPA on air conditioners and energy management systems. The response of the motor can vary greatly depending on the type of protection and control. The time duration for the voltage sag consists of those times that are of interest for bulk power system modelers.

  20. Mold Remediation in Schools and Commercial Buildings.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    This document describes how to investigate and evaluate moisture and mold problems in educational facilities, and presents the key steps for implementing a remediation plan. A checklist is provided for conducting mold remediation efforts along with a resource list of helpful organizations and governmental agencies. Appendices contain a glossary,…

  1. Building Energy Management Open Source Software

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-20

    This is the repository for Building Energy Management Open Source Software (BEMOSS), which is an open source operating system that is engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. BEMOSS offers the following key features: (1) Open source, open architecture – BEMOSS is an open source operating system that is built upon VOLTTRON – a distributed agent platform developed by Pacific Northwest National Laboratory (PNNL). BEMOSS was designed to make it easy for hardware manufacturers to seamlessly interface their devices with BEMOSS. Software developers can also contribute to adding additional BEMOSS functionalities and applications. (2) Plug & play – BEMOSS was designed to automatically discover supported load controllers (including smart thermostats, VAV/RTUs, lighting load controllers and plug load controllers) in commercial buildings. (3) Interoperability – BEMOSS was designed to work with load control devices form different manufacturers that operate on different communication technologies and data exchange protocols. (4) Cost effectiveness – Implementation of BEMOSS deemed to be cost-effective as it was built upon a robust open source platform that can operate on a low-cost single-board computer, such as Odroid. This feature could contribute to its rapid deployment in small- or medium-sized commercial buildings. (5) Scalability and ease of deployment – With its multi-node architecture, BEMOSS provides a distributed architecture where load controllers in a multi-floor and high occupancy building could be monitored and controlled by multiple single-board computers hosting BEMOSS. This makes it possible for a building engineer to deploy BEMOSS in one zone of a building, be comfortable with its operation, and later on expand the deployment to the entire building to make it more energy efficient. (6) Ability to provide local and remote monitoring – BEMOSS provides both local and remote monitoring

  2. Building energy governance in Shanghai

    Science.gov (United States)

    Kung, YiHsiu Michelle

    With Asia's surging economies and urbanization, the region is adding to its built environment at an unprecedented rate, especially those population centers in China and India. With numerous existing buildings, plus a new building boom, construction in these major Asian cities has caused momentous sustainability challenges. This dissertation focuses on China's leading city, Shanghai, to explore and assess its existing commercial building energy policies and practices. Research estimates that Shanghai's commercial buildings might become a key challenge with regard to energy use and CO2 emissions as compared to other major Asian cities. Relevant building energy policy instruments at national and local levels for commercial buildings are reviewed. In addition, two benchmarks are established to further assess building energy policies in Shanghai. The first benchmark is based on the synthesis of relevant criteria and policy instruments as recommended by professional organizations, while the second practical benchmark is drawn from an analysis of three global cities: New York, London and Tokyo. Moreover, two large-scale commercial building sites - Shanghai IKEA and Plaza 66 - are selected for investigation and assessment of their efforts on building energy saving measures. Detailed building energy savings, CO2 reductions, and management cost reductions based on data availability and calculations are presented with the co-benefits approach. The research additionally analyzes different interventions and factors that facilitate or constrain the implementation process of building energy saving measures in each case. Furthermore, a multi-scale analytical framework is employed to investigate relevant stakeholders that shape Shanghai's commercial building energy governance. Research findings and policy recommendations are offered at the close of this dissertation. Findings and policy recommendations are intended to facilitate commercial building energy governance in Shanghai and

  3. Energy consumptions in existing buildings; Les consommations d'energie des batiments existants

    Energy Technology Data Exchange (ETDEWEB)

    Nuss, St. [Ecole Nationale Superieure des Arts et Industries de Strasbourg, 78 - Saint-Remy-Les-Chevreuse (France)]|[Costic, 78 - Sainte Remy les Chevreuses (France)

    2002-05-01

    This document presents a sectoral analysis of the energy consumptions in existing French buildings: 1) - residential sector: social buildings, private dwellings; 2) - tertiary sector: office buildings, hotels, commercial buildings, school buildings, hospitals; 3) - industry; 4) - general status. (J.S.)

  4. Interface dermatitis

    Directory of Open Access Journals (Sweden)

    Rajiv Joshi

    2013-01-01

    Full Text Available Interface dermatitis includes diseases in which the primary pathology involves the dermo-epidermal junction. The salient histological findings include basal cell vacuolization, apoptotic keratinocytes (colloid or Civatte bodies, and obscuring of the dermo-epidermal junction by inflammatory cells. Secondary changes of the epidermis and papillary dermis along with type, distribution and density of inflammatory cells are used for the differential diagnoses of the various diseases that exhibit interface changes. Lupus erythematosus, dermatomyositis, lichen planus, graft versus host disease, erythema multiforme, fixed drug eruptions, lichen striatus, and pityriasis lichenoides are considered major interface diseases. Several other diseases (inflammatory, infective, and neoplastic may show interface changes.

  5. Interface Screenings

    DEFF Research Database (Denmark)

    Thomsen, Bodil Marie Stavning

    2015-01-01

    and memories. From a transvisual perspective, the question is whether or not these (by now realized) diagrammatic modes involving the body in ubiquitous global media can be analysed in terms of the affects and events created in concrete interfaces. The examples used are filmic as felt sensations...... of an interface are invisible and not easy to describe....

  6. Fluid Interfaces

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius

    2001-01-01

    Fluid interaction, interaction by the user with the system that causes few breakdowns, is essential to many user interfaces. We present two concrete software systems that try to support fluid interaction for different work practices. Furthermore, we present specificity, generality, and minimality...... as design goals for fluid interfaces....

  7. Interface Realisms

    DEFF Research Database (Denmark)

    Pold, Søren

    2005-01-01

    This article argues for seeing the interface as an important representational and aesthetic form with implications for postmodern culture and digital aesthetics. The interface emphasizes realism due in part to the desire for transparency in Human-Computer Interaction (HCI) and partly to the devel...

  8. Testing Interfaces

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Henriksen, Mogens; Nilson, Jesper K.;

    1999-01-01

    The wide use of solid insulating materials combinations in combinations has introduced problems in the interfaces between components. The most common insulating materials are cross-linked polyethylene (XLPE), silicone rubber (SIR) and ethylene-propylene rubbers (EPR). Assemblies of these materials...... have caused major failures. In the Netherlands, a major black out was caused by interface problems in 150kV cable terminations, causing a cascade of breakdowns. There is a need to investigate the reasons for this and other similar breakdowns.The major problem is expected to lie in the interface between...... two different materials. Environmental influence, surface treatment, defects in materials and interface, design, pressure and rubbing are believed to have an effect on interface degradation. These factors are believed to increase the possibility of partial discharges (PD). PD will, with time, destroy...

  9. Commercialization of nanotechnology.

    Science.gov (United States)

    Hobson, David W

    2009-01-01

    The emerging and potential commercial applications of nanotechnologies clearly have great potential to significantly advance and even potentially revolutionize various aspects of medical practice and medical product development. Nanotechnology is already touching upon many aspects of medicine, including drug delivery, diagnostic imaging, clinical diagnostics, nanomedicines, and the use of nanomaterials in medical devices. This technology is already having an impact; many products are on the market and a growing number is in the pipeline. Momentum is steadily building for the successful development of additional nanotech products to diagnose and treat disease; the most active areas of product development are drug delivery and in vivo imaging. Nanotechnology is also addressing many unmet needs in the pharmaceutical industry, including the reformulation of drugs to improve their bioavailability or toxicity profiles. The advancement of medical nanotechnology is expected to advance over at least three different generations or phases, beginning with the introduction of simple nanoparticulate and nanostructural improvements to current product and process types, then eventually moving on to nanoproducts and nanodevices that are limited only by the imagination and limits of the technology itself. This review looks at some recent developments in the commercialization of nanotechnology for various medical applications as well as general trends in the industry, and explores the nanotechnology industry that is involved in developing medical products and procedures with a view toward technology commercialization.

  10. The Strategy Of Ecological Design Of Commercial Buildings Based On The Atrium Type In Hot Summer And Cold Winter Area%基于商业建筑中庭类型的生态设计策略探讨--以夏热冬冷地区为例

    Institute of Scientific and Technical Information of China (English)

    刘宏成; 向俊米

    2016-01-01

    Take the commercial buildings in hot summer and cold winter area as examples, based on the "passive priority" principle ,the article discuss diferent atrium types toward the use of layout, the natural ventilation and lighting and shading ecological strategies,in order to improve the indoor environment of commercial buildings and reduce energy consumption.%本文以夏热冬冷地区的商业建筑为例,以“被动优先”为原则,探讨不同中庭类型的朝向布局、自然采光通风与遮阳等生态策略的运用,以达到改善商业建筑室内环境与减少能源消耗的目的。

  11. Analysis of process and interface structure of straw geopolymer building material with heat preservation%秸秆土聚物保温建筑材料工艺及界面结构分析

    Institute of Scientific and Technical Information of China (English)

    金漫彤; 朱聪颖; 金赞芳

    2015-01-01

    and metakaolin was 0.10. The samples should be cured at temperate of (20±2)℃ and relative humidity of 70%±2% for 7d. The compressive strength of straw-geopolymer can be up to 54.58MPa, and the thermal conductivities of straw-geopolymer which were synthesised under the optimal formula with different straw content (0-6%) were also been studied. Thermal conductivity measurement was based on steady-state method. The results showed that the thermal conductivity of straw-geopolymer decreased with the increase of straw content, and the thermal conductivity of straw-geopolymer at 4% straw content was 0.0681W/(m·K). Comparing the thermal conductivity of straw-geopolymer material with other thermal insulation materials, it can be seen that the thermal conductivity of this material was close to that of cotton stalk insulation board and even smaller than foam concrete. Meanwhile, considering its high temperature resistance,cost saving and environmental contribution, the material synthesized in present work showed potential for building thermal insulation application. As a typical composite material, the interface between geopolymer and reinforcing straw had a significant correlation with the macroscopic properties of straw-reinforced geopolymer. The interface between straw and geopolymer was also studied through XRD, SEM, FT-IR analyses. XRD, SEM and FT-IR analyses results showed that the phases of straw-geopolymer were mainly composed of amorphous phase and crystalline phases of Quartz. The straw-geopolymer was semi-crystal, amorphous phase with Si, O and Al elements. Gaps and cracks were appeared near the straw/geopolymer interface. The cracks were diverged when there were straw, and secondary cracks appeared. The combination interface was week in the geopolymer matrix propagate and grow along the interface between straw and geopolymer. Moreover, new cracks generated approximately perpendicular to the strike direction of the original crack which could absorb plenty of

  12. 75 FR 66709 - Commercial Radio Operators Rules

    Science.gov (United States)

    2010-10-29

    ... delivery, by commercial overnight courier, or by first-class or overnight U.S. Postal Service mail. All... building. The filing hours at this location are 8 a.m. to 7 p.m. Commercial overnight mail (other than U.S... rate of speed specified in Sec. 13.203(b). (2) To pass a sending telegraphy examination, an examinee is...

  13. Integrating a commercial industrial control system to the accelerator control system: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Momal, F. (CERN, Geneva (Switzerland)); Brahy, J. (CERN, Geneva (Switzerland)); Saban, R. (CERN, Geneva (Switzerland)); Sollander, P. (CERN, Geneva (Switzerland))

    1994-12-15

    At CERN a large number of systems providing services (cooling and ventilation, cryogenics, electricity distribution, personnel and building safety, etc.) are controlled by industrial PLCs. A commercial supervision package is used as a gateway to the accelerator control system. The integration of such a system in the CERN accelerator control environment addresses issues such as the connection to control-rooms and desktop computers, alarm logging and remote or alien man-machine interfaces. The paper describes the components of the system and reports the first operational experience. ((orig.))

  14. Integrating a commercial industrial control system to the accelerator control system: a case study

    Science.gov (United States)

    Momal, F.; Brahy, J.; Saban, R.; Sollander, P.

    1994-12-01

    At CERN a large number of systems providing services (cooling and ventilation, cryogenics, electricity distribution, personnel and building safety, etc.) are controlled by industrial PLCs. A commercial supervision package is used as a gateway to the accelerator control system. The integration of such a system in the CERN accelerator control environment addresses issues such as the connection to control-rooms and desktop computers, alarm logging and remote or alien man-machine interfaces. The paper describes the components of the system and reports the first operational experience.

  15. Artful interfaces within biological materials

    Directory of Open Access Journals (Sweden)

    John W.C. Dunlop

    2011-03-01

    Full Text Available Biological materials have a wide range of mechanical properties matching their biological function. This is achieved via complex structural hierarchies, spanning many length scales, arising from the assembly of different sized building blocks during growth. The interfaces between these building blocks can increase resistance to fracture, join materials of different character, make them deform more easily and provide motility. While they represent only a tiny fraction of the overall volume, interfaces are essential for the integrity and function of the overall tissue. Understanding their construction principles, often based on specialized molecular assemblies, may change our current thinking about composite materials.

  16. Precise tuning in platinum-nickel/nickel sulfide interface nanowires for synergistic hydrogen evolution catalysis

    Science.gov (United States)

    Wang, Pengtang; Zhang, Xu; Zhang, Jin; Wan, Sheng; Guo, Shaojun; Lu, Gang; Yao, Jianlin; Huang, Xiaoqing

    2017-01-01

    Comprising abundant interfaces, multicomponent heterostructures can integrate distinct building blocks into single entities and yield exceptional functionalities enabled by the synergistic components. Here we report an efficient approach to construct one-dimensional metal/sulfide heterostructures by directly sulfuring highly composition-segregated platinum-nickel nanowires. The heterostructures possess a high density of interfaces between platinum-nickel and nickel sulfide components, which cooperate synergistically towards alkaline hydrogen evolution reaction. The platinum-nickel/nickel sulfide heterostructures can deliver a current density of 37.2 mA cm−2 at an overpotential of 70 mV, which is 9.7 times higher than that of commercial Pt/C. The heterostructures also offer enhanced stability revealed by long-term chronopotentiometry measurements. The present work highlights a potentially powerful interface-engineering strategy for designing multicomponent heterostructures with advanced performance in hydrogen evolution reaction and beyond. PMID:28239145

  17. Microprocessor interfacing

    CERN Document Server

    Vears, R E

    2014-01-01

    Microprocessor Interfacing provides the coverage of the Business and Technician Education Council level NIII unit in Microprocessor Interfacing (syllabus U86/335). Composed of seven chapters, the book explains the foundation in microprocessor interfacing techniques in hardware and software that can be used for problem identification and solving. The book focuses on the 6502, Z80, and 6800/02 microprocessor families. The technique starts with signal conditioning, filtering, and cleaning before the signal can be processed. The signal conversion, from analog to digital or vice versa, is expl

  18. SIA model for buildings: energy-efficiency path for commercial and residential buildings. Preliminary study on the Swiss model for buildings - Basics for the revision of the 'SIA energy-efficiency path' - Final report; Gebaeudeparkmodell 'SIA Effizienzpfad Energie', Dienstleistungs- und Wohngebaeude. Vorstudie zum Gebaeudeparkmodell Schweiz - Grundlagen zur Ueberarbeitung des SIA Effizienzpfades Energie - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Heeren, N.; Gabathuler, M.; Wallbaum, H. [Institut fuer Bauplanung und Baubetrieb, Eidgenoessische Technische Hochschule Zuerich (ETHZ), Zuerich (Switzerland); Jakob, M.; Martius, M.; Gross, N. [TEP Energy GmbH, Technology Economics Policy - Research and Advice, Zuerich (Switzerland)

    2009-10-15

    The aim of the project was to provide a basis for the revision of the so-called 'Efficiency Path' of the Swiss Association of Engineers and Architects (SIA) in the context of the goals of the 2000-Watt-Society. Particularly, the objective is to find the conditions in which the specific goals of the 2000-Watt-Society for residential, school and office buildings could be reached. Considered indicators are the per capita primary energy use in terms of average power and the greenhouse gas emissions. A bottom-up model was developed to estimate final and primary energy demand of the mentioned building types, broken down by different types of energy utilisation. Assumptions were made regarding the most important physical drivers as well as for regarding energy efficiency parameters of new buildings, building retrofits, building technologies and other energy applications in the residential, school and office buildings. Two basic scenarios were developed: an ambitious efficiency scenario was compared to a reference scenario which included current and foreseeable energy policy elements. Regarding electricity supply three scenario-variants of the so-called Swiss Energy Perspectives of the Swiss Federal Office of Energy (SFOE) were used: variant I b 'business-as-usual - nuclear and central fossil plants', IV a: Path to the 2000-Watt-Society - nuclear' and, IV e 'Path to the 2000-Watt-Society - renewable energies'. With this respect it was found that in the case of the efficiency scenario the influence of the electricity generation mix is relatively small. This finding is explained by the fact that hydro power (which is held more or less at the current level) has a large share in the power supply mix in the case of the efficiency scenario with moderate electricity demand and that hydro power is efficient in terms of primary energy and has considerably low greenhouse gas emissions. The results of the study show that with the underlying

  19. Interface Input/Output Automata

    DEFF Research Database (Denmark)

    Larsen, Kim Guldstrand; Nyman, Ulrik; Wasowski, Andrzej

    2006-01-01

    Building on the theory of interface automata by de Alfaro and Henzinger we design an interface language for Lynch’s I/O, a popular formalism used in the development of distributed asynchronous systems, not addressed by previous interface research. We introduce an explicit separation of assumptions...... from guarantees not yet seen in other behavioral interface theories. Moreover we derive the composition operator systematically and formally, guaranteeing that the resulting compositions are always the weakest in the sense of assumptions, and the strongest in the sense of guarantees. We also present...... a method for solving systems of relativized behavioral inequalities as used in our setup and draw a formal correspondence between our work and interface automata....

  20. Interface-assisted molecular spintronics

    Energy Technology Data Exchange (ETDEWEB)

    Raman, Karthik V. [Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560012 (India)

    2014-09-15

    Molecular spintronics, a field that utilizes the spin state of organic molecules to develop magneto-electronic devices, has shown an enormous scientific activity for more than a decade. But, in the last couple of years, new insights in understanding the fundamental phenomena of molecular interaction on magnetic surfaces, forming a hybrid interface, are presenting a new pathway for developing the subfield of interface-assisted molecular spintronics. The recent exploration of such hybrid interfaces involving carbon based aromatic molecules shows a significant excitement and promise over the previously studied single molecular magnets. In the above new scenario, hybridization of the molecular orbitals with the spin-polarized bands of the surface creates new interface states with unique electronic and magnetic character. This study opens up a molecular-genome initiative in designing new handles to functionalize the spin dependent electronic properties of the hybrid interface to construct spin-functional tailor-made devices. Through this article, we review this subject by presenting a fundamental understanding of the interface spin-chemistry and spin-physics by taking support of advanced computational and spectroscopy tools to investigate molecular spin responses with demonstration of new interface phenomena. Spin-polarized scanning tunneling spectroscopy is favorably considered to be an important tool to investigate these hybrid interfaces with intra-molecular spatial resolution. Finally, by addressing some of the recent findings, we propose novel device schemes towards building interface tailored molecular spintronic devices for applications in sensor, memory, and quantum computing.

  1. Embodied agents in de interface

    NARCIS (Netherlands)

    Evers, M.J.; Nijholt, A.

    2001-01-01

    Steeds meer zien we het gebruik van mensachtige, geanimeerde figuren in interfaces en andere software applicaties, niet alleen in onderzoeksprojecten maar ook in commerciële software. Een voorbeeld dat bijna iedereen wel kent (en waar velen wel wat op aan te merken hebben) is de ‘office assistant’ i

  2. Indoor Air Quality Building Education and Assessment Model Forms

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  3. Indoor Air Quality Building Education and Assessment Model

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM), released in 2002, is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  4. A Buildings Module for the Stochastic Energy Deployment System

    Energy Technology Data Exchange (ETDEWEB)

    Lacommare, Kristina S H; Marnay, Chris; Stadler, Michael; Borgeson, Sam; Coffey, Brian; Komiyama, Ryoichi; Lai, Judy

    2008-05-15

    The U.S. Department of Energy (USDOE) is building a new long-range (to 2050) forecasting model for use in budgetary and management applications called the Stochastic Energy Deployment System (SEDS), which explicitly incorporates uncertainty through its development within the Analytica(R) platform of Lumina Decision Systems. SEDS is designed to be a fast running (a few minutes), user-friendly model that analysts can readily run and modify in its entirety through a visual programming interface. Lawrence Berkeley National Laboratory is responsible for implementing the SEDS Buildings Module. The initial Lite version of the module is complete and integrated with a shared code library for modeling demand-side technology choice developed by the National Renewable Energy Laboratory (NREL) and Lumina. The module covers both commercial and residential buildings at the U.S. national level using an econometric forecast of floorspace requirement and a model of building stock turnover as the basis for forecasting overall demand for building services. Although the module is fundamentally an engineering-economic model with technology adoption decisions based on cost and energy performance characteristics of competing technologies, it differs from standard energy forecasting models by including considerations of passive building systems, interactions between technologies (such as internal heat gains), and on-site power generation.

  5. Configurable Radiation Hardened High Speed Isolated Interface ASIC Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NVE Corporation will design and build an innovative, low cost, flexible, configurable, radiation hardened, galvanically isolated, interface ASIC chip set that will...

  6. General purpose operator interface

    Energy Technology Data Exchange (ETDEWEB)

    Bennion, S. I.

    1979-07-01

    The Hanford Engineering Development Laboratory in Richland, Washington is developing a general-purpose operator interface for controlling set-point driven processes. The interface concept is being developed around graphics display devices with touch-sensitive screens for direct interaction with the displays. Additional devices such as trackballs and keyboards are incorporated for the operator's convenience, but are not necessary for operation. The hardware and software are modular; only those capabilities needed for a particular application need to be used. The software is written in FORTRAN IV with minimal use of operating system calls to increase portability. Several ASCII files generated by the user define displays and correlate the display variables with the process parameters. It is also necessary for the user to build an interface routine which translates the internal graphics commands into device-specific commands. The interface is suited for both continuous flow processes and unit operations. An especially useful feature for controlling unit operations is the ability to generate and execute complex command sequences from ASCII files. This feature relieves operators of many repetitive tasks. 2 figures.

  7. Digital interface for high-resolution displays

    Science.gov (United States)

    Hermann, David J.; Gorenflo, Ronald L.

    1999-08-01

    Commercial display interfaces are currently transitioning from analog to digital. Although this transition is in the very early stages, the military needs to begin planning their own transition to digital. There are many problems with the analog interface in high-resolution display systems that are solved by changing to a digital interface. Also, display system cost can be lower with a digital interface to a high resolution display. Battelle is under contract with DARPA to develop an advanced Display Interface (ADI) to replace the analog RGB interfaces currently used in high definition workstation displays. The goal is to create a standard digital display interface for military applications that is based on emerging commercial standards. Support for military application- specific functionality is addressed, including display test and control. The main challenges to implementing a digital display interface are described, along with approaches to address the problems. Conceptual ADI architectures are described and contrasted. The current and emerging commercial standards for digital display interfaces are reviewed in detail. Finally, the tasks required to complete the ADI effort are outlined and described.

  8. Designing Interfaces

    CERN Document Server

    Tidwell, Jenifer

    2010-01-01

    Despite all of the UI toolkits available today, it's still not easy to design good application interfaces. This bestselling book is one of the few reliable sources to help you navigate through the maze of design options. By capturing UI best practices and reusable ideas as design patterns, Designing Interfaces provides solutions to common design problems that you can tailor to the situation at hand. This updated edition includes patterns for mobile apps and social media, as well as web applications and desktop software. Each pattern contains full-color examples and practical design advice th

  9. Utilizing Bayesian Techniques for User Interface Intelligence

    Science.gov (United States)

    1996-12-01

    rea - soning and knowledge) have placed little or no emphasis on the expert system user interface. These developers spend most resources perfecting the...1994). 24. Cesta, Amedeo and Daniela DAloisi. "Building Interfaces as Personal Assis- tants," SIGCHI Bulletin, 28(3):108-113 (1996). 25. Chappel, H

  10. Building Air Quality Guide: A Guide for Building Owners and Facility Managers

    Science.gov (United States)

    The Building Air Quality, developed by the EPA and the National Institute for Occupational Safety and Health, provides practical suggestions on preventing, identifying, and resolving indoor air quality (IAQ) problems in public and commercial buildings.

  11. Building Materials

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ Building Materials Sub-council of CCPIT is the other sub-council in construction field. CCPIT Building Materials Sub-council (CCPITBM), as well as CCOIC Build-ing Materials Chamber of Commerce, is au-thorized by CCPIT and state administration of building materials industry in 1992. CCPITBM is a sub-organization of CCPIT and CCOIC.

  12. Gesture Interfaces

    NARCIS (Netherlands)

    Fikkert, F.W.

    2007-01-01

    Take away mouse and keyboard. Now, how do you interact with a computer? Especially one that has a display that is the size of an entire wall. One possibility is through gesture interfaces. Remember Minority Report? Cool stuff, but that was already five years ago.. So, what is already possible now an

  13. Manufacturing Interfaces

    NARCIS (Netherlands)

    Houten, van F.J.A.M.

    1992-01-01

    The paper identifies the changing needs and requirements with respect to the interfacing of manufacturing functions. It considers the manufacturing system, its components and their relationships from the technological and logistic point of view, against the background of concurrent engineering. Desi

  14. Testing Interfaces

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Henriksen, Mogens; Nilson, Jesper K.;

    1999-01-01

    The wide use of solid insulating materials combinations in combinations has introduced problems in the interfaces between components. The most common insulating materials are cross-linked polyethylene (XLPE), silicone rubber (SIR) and ethylene-propylene rubbers (EPR). Assemblies of these materials...

  15. High Performance Commercial Fenestration Framing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mike Manteghi; Sneh Kumar; Joshua Early; Bhaskar Adusumalli

    2010-01-31

    A major objective of the U.S. Department of Energy is to have a zero energy commercial building by the year 2025. Windows have a major influence on the energy performance of the building envelope as they control over 55% of building energy load, and represent one important area where technologies can be developed to save energy. Aluminum framing systems are used in over 80% of commercial fenestration products (i.e. windows, curtain walls, store fronts, etc.). Aluminum framing systems are often required in commercial buildings because of their inherent good structural properties and long service life, which is required from commercial and architectural frames. At the same time, they are lightweight and durable, requiring very little maintenance, and offer design flexibility. An additional benefit of aluminum framing systems is their relatively low cost and easy manufacturability. Aluminum, being an easily recyclable material, also offers sustainable features. However, from energy efficiency point of view, aluminum frames have lower thermal performance due to the very high thermal conductivity of aluminum. Fenestration systems constructed of aluminum alloys therefore have lower performance in terms of being effective barrier to energy transfer (heat loss or gain). Despite the lower energy performance, aluminum is the choice material for commercial framing systems and dominates the commercial/architectural fenestration market because of the reasons mentioned above. In addition, there is no other cost effective and energy efficient replacement material available to take place of aluminum in the commercial/architectural market. Hence it is imperative to improve the performance of aluminum framing system to improve the energy performance of commercial fenestration system and in turn reduce the energy consumption of commercial building and achieve zero energy building by 2025. The objective of this project was to develop high performance, energy efficient commercial

  16. The design of an intelligent human-computer interface for the test, control and monitor system

    Science.gov (United States)

    Shoaff, William D.

    1988-01-01

    The graphical intelligence and assistance capabilities of a human-computer interface for the Test, Control, and Monitor System at Kennedy Space Center are explored. The report focuses on how a particular commercial off-the-shelf graphical software package, Data Views, can be used to produce tools that build widgets such as menus, text panels, graphs, icons, windows, and ultimately complete interfaces for monitoring data from an application; controlling an application by providing input data to it; and testing an application by both monitoring and controlling it. A complete set of tools for building interfaces is described in a manual for the TCMS toolkit. Simple tools create primitive widgets such as lines, rectangles and text strings. Intermediate level tools create pictographs from primitive widgets, and connect processes to either text strings or pictographs. Other tools create input objects; Data Views supports output objects directly, thus output objects are not considered. Finally, a set of utilities for executing, monitoring use, editing, and displaying the content of interfaces is included in the toolkit.

  17. Energy Consumption and Energy Conservation Potential Analysis for One Commercial-and-Residential Building in Shanghai%上海某大型商住两用建筑的用能情况分析及节能潜力研究

    Institute of Scientific and Technical Information of China (English)

    孔繁伟

    2013-01-01

    The basic information and energy consumption of a commercial-and-residential building in Shanghai were investigated. The energy conservation potential and economical efficiency were expounded with the data statistic and division analysis of energy consumption ac-cording to different building systems.%  通过对上海地区某大型商住两用建筑的基本信息及用能情况进行实地调研,按照建筑内用能系统进行能耗拆分统计。在此基础上对建筑节能潜力进行研究,并对节能改造的经济性进行分析。

  18. Modules in historic building construction according to the Copenhagen Building Code

    DEFF Research Database (Denmark)

    Kudsk, Anders; Thuesen, Christian Langhoff; Hvam, Lars

    2011-01-01

    This paper describes an analysis of building works from Copenhagen, Denmark in the period 1850 to 1950. In the study we investigate, based on the theory of product architecture and product modularization, if examples of the use of well-defined interfaces can be found. Furthermore, the aim...... is to study how the use of such interfaces has influenced former building processes and how they were implemented and kept stable over decades. The result of the study is that at that time a number of standardized interfaces between the individual parts of the building work existed, and that these interfaces......, and arrangements / agreements between the individual professional groups....

  19. Interface learning

    DEFF Research Database (Denmark)

    Thorhauge, Sally

    2014-01-01

    "Interface learning - New goals for museum and upper secondary school collaboration" investigates and analyzes the learning that takes place when museums and upper secondary schools in Denmark work together in local partnerships to develop and carry out school-related, museum-based coursework...... for students. The research focuses on the learning that the students experience in the interface of the two learning environments: The formal learning environment of the upper secondary school and the informal learning environment of the museum. Focus is also on the learning that the teachers and museum...... professionals experience as a result of their collaboration. The dissertation demonstrates how a given partnership’s collaboration affects the students’ learning experiences when they are doing the coursework. The dissertation presents findings that museum-school partnerships can use in order to develop...

  20. Museets interface

    DEFF Research Database (Denmark)

    Pold, Søren

    2007-01-01

    Søren Pold gør sig overvejelser med udgangspunkt i museumsprojekterne Kongedragter.dk og Stigombord.dk. Han argumenterer for, at udviklingen af internettets interfaces skaber nye måder at se, forstå og interagere med kulturen på. Brugerne får nye medievaner og perceptionsmønstre, der må medtænkes i...

  1. Museets interface

    DEFF Research Database (Denmark)

    Pold, Søren

    2007-01-01

    Søren Pold gør sig overvejelser med udgangspunkt i museumsprojekterne Kongedragter.dk og Stigombord.dk. Han argumenterer for, at udviklingen af internettets interfaces skaber nye måder at se, forstå og interagere med kulturen på. Brugerne får nye medievaner og perceptionsmønstre, der må medtænkes i...

  2. 探访安藤忠雄的商业建筑与入驻品牌%The Visit of Commercial Buildings with the Brands Designed by TADAO ANDO

    Institute of Scientific and Technical Information of China (English)

    黄国磊; 孙斐; 高博

    2011-01-01

    Through introduction of five individual works of commercial architecture designed by Tadao Andou in Kobe,Kyoto and Osaka,The paper unfolds design feature of Tadao Andou with outstanding individuality again,though the type,function and usage rate investigation of these commercial brands,it further discusses the suitability principle between personalized commercial space and commercial content,brand.%通过介绍安藤忠雄在神户、京都、大阪等地五座个性的商业建筑作品,再一次展现了安藤忠雄个性鲜明的设计特点在商业空间中的体现;通过对入驻其中商业品牌的种类、功能与使用率状况进行的调研分析,进一步探讨了个性化商业空间与其承载的商业内容及品牌的适配性原则。

  3. The conversational interface talking to smart devices

    CERN Document Server

    McTear, Michael; Griol, David

    2016-01-01

    This book provides a comprehensive introduction to the conversational interface, which is becoming the main mode of interaction with virtual personal assistants, smart devices, various types of wearables, and social robots. The book consists of four parts: Part I presents the background to conversational interfaces, examining past and present work on spoken language interaction with computers; Part II covers the various technologies that are required to build a conversational interface along with practical chapters and exercises using open source tools; Part III looks at interactions with smart devices, wearables, and robots, and then goes on to discusses the role of emotion and personality in the conversational interface; Part IV examines methods for evaluating conversational interfaces and discusses future directions. · Presents a comprehensive overview of the various technologies that underlie conversational user interfaces; · Combines descriptions of conversational user interface technologies with a gui...

  4. 以消费者行为为导向的体验式商业建筑设计--以山西临汾西华名邸商业街为例%Design of Experiential Commercial Buildings to the Consumer Behavior Oriented -- Taking Shanxi Linfen Xihua Mingdi Commercial Street as an Example

    Institute of Scientific and Technical Information of China (English)

    丁曦明; 李军祥

    2014-01-01

    商业街作为一种特殊形态的空间,是以消费者的行为为基础的。本文在消费行为研究的基础上,结合当前体验式商业模式的发展方向,以山西临汾西华名邸商业街的规划和设计理念为例,探讨了现代商业街的规划设计方法。%Commercial Street, as a special form of space, is based on the consumer behavior. This paper based on study of consumer behavior, combined with the development direction of current experiential commercial patern, with the planning and the design idea of Shanxi Linfen Xihua Mingdi Comme- rcial Street as an example, discussed the planning method for modern commercial streets.

  5. SNE Industrial Fieldbus Interface

    Science.gov (United States)

    Lucena, Angel; Raines, Matthew; Oostdyk, Rebecca; Mata, Carlos

    2011-01-01

    Programmable logic controllers (PLCs) have very limited diagnostic and no prognostic capabilities, while current smart sensor designs do not have the capability to communicate over Fieldbus networks. The aim is to interface smart sensors with PLCs so that health and status information, such as failure mode identification and measurement tolerance, can be communicated via an industrial Fieldbus such as ControlNet. The SNE Industrial Fieldbus Interface (SIFI) is an embedded device that acts as a communication module in a networked smart sensor. The purpose is to enable a smart sensor to communicate health and status information to other devices, such as PLCs, via an industrial Fieldbus networking protocol. The SNE (Smart Network Element) is attached to a commercial off-the-shelf Any bus-S interface module through the SIFI. Numerous Anybus-S modules are available, each one designed to interface with a specific Fieldbus. Development of the SIFI focused on communications using the ControlNet protocol, but any of the Anybus-S modules can be used. The SIFI communicates with the Any-bus module via a data buffer and mailbox system on the Anybus module, and supplies power to the module. The Anybus module transmits and receives data on the Fieldbus using the proper protocol. The SIFI is intended to be connected to other existing SNE modules in order to monitor the health and status of a transducer. The SIFI can also monitor aspects of its own health using an onboard watchdog timer and voltage monitors. The SIFI also has the hardware to drive a touchscreen LCD (liquid crystal display) unit for manual configuration and status monitoring.

  6. Chapter 15: Commercial New Construction Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Keates, S.

    2014-09-01

    This protocol is intended to describe the recommended method when evaluating the whole-building performance of new construction projects in the commercial sector. The protocol focuses on energy conservation measures (ECMs) measures (or packages of measures) where evaluators can best analyze impacts using building simulation. These ECMs typically require the use of calibrated building simulations under Option D of the International Performance Measurement and Verification Protocol. Examples of such measures include Leadership in Energy and Environmental Design building certification, novel and/or efficient heating, ventilation, and air conditioning system designs, and extensive building controls systems. In general, it is best to evaluate any ECM (or set of measures) expected to significantly interact with other systems within the building and with savings sensitive to seasonal variations in weather.

  7. MARKETING STRATEGY OF COMMERCIALIZATION OF INNOVATION

    OpenAIRE

    2013-01-01

    The purpose of the article is to develop an original approach to the formation of a marketing strategy of commercialization of innovations. The existing views on the process of creating marketing strategies were examined and classified and the algorithm of building marketing strategies for the processes commercialization of innovations was offered. The results can be used by industrial companies and in the educational process of marketing, strategic marketing and innovation management discipl...

  8. MARKETING STRATEGY OF COMMERCIALIZATION OF INNOVATION

    Directory of Open Access Journals (Sweden)

    Savelyeva Irina Petrovna

    2013-04-01

    Full Text Available The purpose of the article is to develop an original approach to the formation of a marketing strategy of commercialization of innovations. The existing views on the process of creating marketing strategies were examined and classified and the algorithm of building marketing strategies for the processes commercialization of innovations was offered. The results can be used by industrial companies and in the educational process of marketing, strategic marketing and innovation management disciplines.

  9. An Interface Theory for Input/Output Automata

    DEFF Research Database (Denmark)

    Larsen, Kim Guldstrand; Nyman, Ulrik; Wasowski, Andrzej

    Building on the theory of interface automata by de~Alfaro and Henzinger we design an interface language for Lynch's Input/Output Automata, a popular formalism used in the development of distributed asynchronous systems, not addressed by previous interface research. We introduce an explicit separa...

  10. Refinement of a SPR sensor for application within air-tight buildings

    Science.gov (United States)

    Bryce, Emma; Sommerville, James; Aidoo, Kofi

    2009-08-01

    The development of air-tight buildings to significantly reduce the carbon emissions from buildings is a relatively new building technique. However the side effects of the new approach have not been fully investigated. One potential issue arising is from insufficient ventilation resulting in an increase in poor indoor air quality from exacerbated microbial growth through elevated humidity and temperature. At the moment there is no in situ real-time sensor for the detection of multiple microbes within the built environment. Developing a sensor utilizing the phenomena of Surface Plasmon Resonance as its detection method to continuously monitor in situ multiple microbial species and fungi is being undertaken. The research involves the refinement of the specialised instruments commercially available, simplifying the components and advancing the architecture of the interface allowing for the monitoring of multiple species and a novel output detection method.

  11. Improving Building Energy Efficiency in India: State-level Analysis of Building Energy Efficiency Policies

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sha; Tan, Qing; Evans, Meredydd; Kyle, Gordon P.; Vu, Linh D.; Patel, Pralit L.

    2017-11-01

    India is expected to add 40 billion m2 of new buildings till 2050. Buildings are responsible for one third of India’s total energy consumption today and building energy use is expected to continue growing driven by rapid income and population growth. The implementation of the Energy Conservation Building Code (ECBC) is one of the measures to improve building energy efficiency. Using the Global Change Assessment Model, this study assesses growth in the buildings sector and impacts of building energy policies in Gujarat, which would help the state adopt ECBC and expand building energy efficiency programs. Without building energy policies, building energy use in Gujarat would grow by 15 times in commercial buildings and 4 times in urban residential buildings between 2010 and 2050. ECBC improves energy efficiency in commercial buildings and could reduce building electricity use in Gujarat by 20% in 2050, compared to the no policy scenario. Having energy codes for both commercial and residential buildings could result in additional 10% savings in electricity use. To achieve these intended savings, it is critical to build capacity and institution for robust code implementation.

  12. Commercialization and Pasisir Culture

    OpenAIRE

    Suryo, Djoko

    2013-01-01

    Commercialization process and the establishment of coastal culture in Javawas one united history process where one cannot be separated from the other. The commercialization process and the establishment of the coastal culture cannot be separated from the commercialization process and the establishment of Malay World in South East Asia. In other words, we can say that basically, commercialization process and the establishment of the coastal culture had been part of commercialization process an...

  13. From Cultural Identity to Consumptive Identity: Commercial Analysis on Cultural Building%从文化认同到消费认同——文化建筑的商业图解

    Institute of Scientific and Technical Information of China (English)

    董屹

    2012-01-01

    Starting from the symbiosis of culture and consumption, this article makes a thought on the new problems brought by the cultural building as a social public platform that is more and more permeated by the consumptive activities. It also makes a discussion on the transformation from cultural identity to consumptive identity and the change of the design of cultural building based on the consumptive identity. It puts forward an opinion that we should have a critical attitude towards the relationship between the culture and consumption in the cultural building and focus on the promoting value between them.%本文从文化与消费的共生切入,思考当今文化建筑作为社会公共活动平台,越来越多的被消费活动所渗透而带来的新问题,探讨从文化认同到消费认同的过程和消费图解下的文化建筑设计的改变,提出应批判看待文化建筑中文化与消费的关系,并且关注二者相互间的促进价值。

  14. Energy Innovations for Healthy Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Bogucz, Edward A. [Syracuse Univ., NY (United States)

    2016-09-23

    Healthy buildings provide high indoor environmental quality for occupants while simultaneously reducing energy consumption. This project advanced the development and marketability of envisioned healthy, energy-efficient buildings through studies that evaluated the use of emerging technologies in commercial and residential buildings. The project also provided resources required for homebuilders to participate in DOE’s Builders Challenge, concomitant with the goal to reduce energy consumption in homes by at least 30% as a first step toward achieving envisioned widespread availability of net-zero energy homes by 2030. In addition, the project included outreach and education concerning energy efficiency in buildings.

  15. Building calculations

    DEFF Research Database (Denmark)

    Jensen, Bjarne Christian; Hansen, Svend Ole

    Textbook on design of large panel building including rules on robustness and a method for producing the Statical documentattion......Textbook on design of large panel building including rules on robustness and a method for producing the Statical documentattion...

  16. Building America

    Energy Technology Data Exchange (ETDEWEB)

    Brad Oberg

    2010-12-31

    IBACOS researched the constructability and viability issues of using high performance windows as one component of a larger approach to building houses that achieve the Building America 70% energy savings target.

  17. Solar building

    OpenAIRE

    Zhang, Luxin

    2014-01-01

    In my thesis I describe the utilization of solar energy and solar energy with building integration. In introduction it is also mentioned how the solar building works, trying to make more people understand and accept the solar building. The thesis introduces different types of solar heat collectors. I compared the difference two operation modes of solar water heating system and created examples of solar water system selection. I also introduced other solar building applications. It is conv...

  18. The Commercial Energy Consumer: About Whom Are We Speaking?

    Energy Technology Data Exchange (ETDEWEB)

    Payne, Christopher

    2006-05-12

    Who are commercial sector customers, and how do they make decisions about energy consumption and energy efficiency investment? The energy policy field has not done a thorough job of describing energy consumption in the commercial sector. First, the discussion of the commercial sector itself is dominated by discussion of large businesses/buildings. Second, discussion of this portion of the commercial sectors consumption behavior is driven primarily by theory, with very little field data collected on the way commercial sector decision-makers describe their own options, choices, and reasons for taking action. These limitations artificially constrain energy policy options. This paper reviews the extant literature on commercial sector energy consumption behavior and identifies gaps in our knowledge. In particular, it argues that the primary energy policy model of commercial sector energy consumption is a top-down model that uses macro-level investment data to make conclusions about commercial behavior. Missing from the discussion is a model of consumption behavior that builds up to a theoretical framework informed by the micro-level data provided by commercial decision-makers themselves. Such a bottom-up model could enhance the effectiveness of commercial sector energy policy. In particular, translation of some behavioral models from the residential sector to the commercial sector may offer new opportunities for policies to change commercial energy consumption behavior. Utility bill consumption feedback is considered as one example of a policy option that may be applicable to both the residential and small commercial sector.

  19. Healthy Buildings?

    Science.gov (United States)

    Grubb, Deborah

    Health problems related to school buildings can be categorized in five major areas: sick-building syndrome; health-threatening building materials; environmental hazards such as radon gas and asbestos; lead poisoning; and poor indoor air quality due to smoke, chemicals, and other pollutants. This paper provides an overview of these areas,…

  20. Building envelope

    CSIR Research Space (South Africa)

    Gibberd, Jeremy T

    2009-01-01

    Full Text Available This chapter describes the way building envelopes can contribute to developing green buildings and sets out some objectives that could be aimed for. It also proposes a number of approaches that can be used to help design green building envelopes...

  1. Commercial Communication in the Spanish Language.

    Science.gov (United States)

    Reinhardt-Childers, Ilva

    A college course in commercial Spanish is described. The course objectives are to: build a solid foundation of business and professional vocabulary, grammar, spelling, and punctuation; prepare for oral and written communication with commonly-used Spanish business phrases and terminology; expose students to the different types of written…

  2. System Integration and Interface Transition Issues.

    Science.gov (United States)

    1977-04-01

    Continue onl reverse side It necesay and identify by block number) System Interfaces Program Objectives System-Level Issues Digitization Strategy DCS... DIGITIZATION STRATEGY IV-1 1. Digitization Considerations IV-l a. Commercial IV-1 b. Current DCS Digitization IV-2 c. DCS Transition IV-2 2. Overseas...Subsystems and Elements 3. AUTOSEVOCOM Il/Digital Transmission Interface VIII-I 4. Transmission Digitization Strategy - PCM Vs. DM VIII-2 5. DCS Encryption

  3. 城区商业楼停车场规划与设计案例分析%Case analysis on parking planning and design of commercial urban building

    Institute of Scientific and Technical Information of China (English)

    汪涛

    2014-01-01

    By selecting famous commercial mansions in Shanghai and Guangzhou as cases, the paper mainly compares and analyzes parking de-sign and operation benefits from aspects of regional characteristics, spatial layout, traffic organization and traffic facility construction, which has important referring value for domestic underground comer parking planning and management.%选取上海及广州著名商业大厦为案例蓝本,重点从区位特征、空间布局、交通组织、交通设施建设等方面对比分析其配套停车场的设计和运营效益,研究成果对我国商业建筑地下停车场规划、运营及管理具有重要的实践参考价值。

  4. Pulse-width modulation for small heat pump installations - Phase 2: implementation in a commercial controller and tests in a residential building; Pulsbreitenmodulation fuer Kleinwaermepumpenanlagen. Phase 2: Implementierung in handelsuebliche Regler und Erprobung in einem Wohnhaus

    Energy Technology Data Exchange (ETDEWEB)

    Gabathuler, H.R.; Mayer, H. [Gabathuler AG, Diessenhofen (Switzerland); Shafai, E.; Wimmer, R. [Eidgenoessische Technische Hochschule, Institut fuer Mess- und Regeltechnik, Zuerich (Switzerland); Frei, R. [Satag Thermotechnik AG, Arbon (Switzerland); Illi, B.; Sidler, F. [Siemens Building Technologies AG, Zug (Switzerland)

    2002-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project in which a new type of controller for small heat pumps used to heat single-family houses was developed. Instead of the two-point controller normally used to control flow or return temperatures in the heating system, three new approaches are described that deliver the heating energy required for a whole day in portions according to prevailing weather conditions and the thermal characteristics of the house and the heat pump. Electricity tariffs are also taken into account and peak-rate periods avoided. The results of the investigations show that all three variants can be implemented using commercially available controllers. Further investigations, including a complete and representative comparison of the three concepts and a conventional control system are foreseen in phase 3 of the project.

  5. Straw insulated buildings. Nature building materials; Strohgedaemmte Gebaeude. Naturbaustoffe

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-06-01

    Straw is one of the major agricultural by-products and is mainly used as litter in animal husbandry and to compensate the balance of humus. A relatively recent development is the use of straw bales for the construction of buildings. The brochure under consideration documents the technical development of straw construction in Germany. Possibilities of the use of straw in single family homes up to commercial buildings are described.

  6. On commercial media bias

    OpenAIRE

    Germano, Fabrizio

    2008-01-01

    Within the spokes model of Chen and Riordan (2007) that allows for non-localized competition among arbitrary numbers of media outlets, we quantify the effect of concentration of ownership on quality and bias of media content. A main result shows that too few commercial outlets, or better, too few separate owners of commercial outlets can lead to substantial bias in equilibrium. Increasing the number of outlets (commercial and non-commercial) tends to bring down this bias; but the strongest ef...

  7. Commercial Radio as Communication.

    Science.gov (United States)

    Rothenbuhler, Eric W.

    1996-01-01

    Compares the day-to-day work routines of commercial radio with the principles of a theoretical communication model. Illuminates peculiarities of the conduct of communication by commercial radio. Discusses the application of theoretical models to the evaluation of practicing institutions. Offers assessments of commercial radio deriving from…

  8. Sustainable building versus ecological building

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2010-04-01

    Full Text Available and sensitivity to a site that are required to efficiently meet the energy needs of a building and occupants with renewable energy (solar, wind, geothermal, etc), designers must apply holistic design principles and take advantage of the free, naturally... Building Handbook Volume 1 Sustainable Building versus Ecological Building Llewellyn van Wyk Principal Researcher CSIR Background and Context ?Evidence is mounting that humankind, and the environment that shapes its existence, are in the midst...

  9. Interfaces habladas

    Directory of Open Access Journals (Sweden)

    María Teresa Soto Sanfiel

    2012-04-01

    Full Text Available Este artículo describe y piensa al fenómeno de las Interfaces habladas (IH desde variados puntos de vista y niveles de análisis. El texto se ha concebido con los objetivos específicos de: 1.- procurar una visión panorámica de aspectos de la producción y consumo comunicativo de las IH; 2.- ofrecer recomendaciones para su creación y uso eficaz, y 3.- llamar la atención sobre su proliferación e inspirar su estudio desde la comunicación. A pesar de la creciente presencia de las IF en nues-tras vidas cotidianas, hay ausencia de textos que las caractericen y analicen por sus aspectos comunicativos. El trabajo es pertinente porque el fenómeno significa un cambio respecto a estadios comunica-tivos precedentes con consecuencias en las concepciones intelectuales y emocionales de los usuarios. La proliferación de IH nos abre a nue-vas realidades comunicativas: hablamos con máquinas.

  10. Assessment of Structural Strength of Commercial Sandcrete Blocks ...

    African Journals Online (AJOL)

    makorede

    construction of residential, industrial and commercial buildings ... (i.e. 460 mm thick blocks) or as partition walls (the 150 mm .... Compressive strength for sandcrete /masonry is presented ... strength, even if the materials are of the required.

  11. Web Interfacing for Task Supervision and Specification

    OpenAIRE

    Tomatis, N.; Moreau, B.

    2001-01-01

    The Autonomous Systems Lab at the Swiss Federal Institute of Technology Lausanne (EPFL) is engaged in mobile robotics research. The lab’s research focuses mainly on indoor localization and map building, outdoor locomotion and navigation, and micro mobile robotics. In the framework of a research project on mobile robot localization, a graphical web interface for our indoor robots has been developed. The purpose of this interface is twofold: it serves as a tool for task supervision for the rese...

  12. Sustainable Building in China—A Green Leap Forward?

    OpenAIRE

    Jialiang Wang; Hongwei Mao; Yongcong Guo; Yutong Li; Tao Yan; Wei Feng; Qing Ye; Diamond, Richard C.

    2013-01-01

    China is constructing new commercial buildings at an enormous rate—roughly 2 billion square meters per year, with considerable interest and activity in green design and construction. We review the context of commercial building design and construction in China, and look at a specific project as an example of a high performance, sustainable design, the Shenzhen Institute of Building Research (IBR). The IBR building incorporates over 40 sustainable technologies and strategies, including dayligh...

  13. Recycling Sounds in Commercials

    DEFF Research Database (Denmark)

    Larsen, Charlotte Rørdam

    2012-01-01

    such references to the past and ‘the good old days’ can be achieved through sounds. In particular, I will look at commercials for Danish non-dairy spreads, especially for OMA margarine. These commercials are notable in that they contain a melody and a slogan – ‘Say the name: OMA margarine’ – that have basically......: in general, the soundtracks of margarine commercials seem to merge into one, they are somewhat alike. The OMA commercials are no exception, but the OMA melody makes a distinction. In general the soundtracks of OMA margarine commercials (and the use of melody) seem to have shifted from using a predominantly...

  14. DIRAC: Secure web user interface

    Energy Technology Data Exchange (ETDEWEB)

    Casajus Ramo, A [University of Barcelona, Diagonal 647, ES-08028 Barcelona (Spain); Sapunov, M, E-mail: sapunov@in2p3.f [Centre de Physique des Particules de Marseille, 163 Av de Luminy Case 902 13288 Marseille (France)

    2010-04-01

    Traditionally the interaction between users and the Grid is done with command line tools. However, these tools are difficult to use by non-expert users providing minimal help and generating outputs not always easy to understand especially in case of errors. Graphical User Interfaces are typically limited to providing access to the monitoring or accounting information and concentrate on some particular aspects failing to cover the full spectrum of grid control tasks. To make the Grid more user friendly more complete graphical interfaces are needed. Within the DIRAC project we have attempted to construct a Web based User Interface that provides means not only for monitoring the system behavior but also allows to steer the main user activities on the grid. Using DIRAC's web interface a user can easily track jobs and data. It provides access to job information and allows performing actions on jobs such as killing or deleting. Data managers can define and monitor file transfer activity as well as check requests set by jobs. Production managers can define and follow large data productions and react if necessary by stopping or starting them. The Web Portal is build following all the grid security standards and using modern Web 2.0 technologies which allow to achieve the user experience similar to the desktop applications. Details of the DIRAC Web Portal architecture and User Interface will be presented and discussed.

  15. Sector-specific issues and reporting methodologies supporting the General Guidelines for the voluntary reporting of greenhouse gases under Section 1605(b) of the Energy Policy Act of 1992. Volume 1: Part 1, Electricity supply sector; Part 2, Residential and commercial buildings sector; Part 3, Industrial sector

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-01

    DOE encourages you to report your achievements in reducing greenhouse gas emissions and sequestering carbon under this program. Global climate change is increasingly being recognized as a threat that individuals and organizations can take action against. If you are among those taking action, reporting your projects may lead to recognition for you, motivation for others, and synergistic learning for the global community. This report discusses the reporting process for the voluntary detailed guidance in the sectoral supporting documents for electricity supply, residential and commercial buildings, industry, transportation, forestry, and agriculture. You may have reportable projects in several sectors; you may report them separately or capture and report the total effects on an entity-wide report.

  16. Connecting Buildings to Public Safety Networks

    Directory of Open Access Journals (Sweden)

    David Holmberg

    2009-12-01

    Full Text Available The operation of modern commercial buildings uses digital control systems which monitor a vast amount of sensors. These sensors in turn produce data that is available for building control but also can be mission-critical for effective emergency response. First responders can be notified of designated building alerts in real-time so that actions can be performed promptly. The capability to monitor building devices and to keep the first responder community updated with the latest building information during emergency situations, as well as the ability to remotely control certain building devices and processes, can be realized. This paper presents a framework for standards-based communication of real-time building alerts, via public safety networks, to 9-1-1 dispatch and into the hands of emergency responders. This research will assist in the development and deployment of commercial products with new levels of capability for situational awareness to help save lives and properties in emergency situations.

  17. Methodology to Assess No Touch Audit Software Using Simulated Building Utility Data

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Howard [Purdue Univ., West Lafayette, IN (United States); Braun, James E. [Purdue Univ., West Lafayette, IN (United States); Langner, M. Rois [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-10-01

    This report describes a methodology developed for assessing the performance of no touch building audit tools and presents results for an available tool. Building audits are conducted in many commercial buildings to reduce building energy costs and improve building operation. Because the audits typically require significant input obtained by building engineers, they are usually only affordable for larger commercial building owners. In an effort to help small building and business owners gain the benefits of an audit at a lower cost, no touch building audit tools have been developed to remotely analyze a building's energy consumption.

  18. Better Buildings Neighborhood Program: BetterBuildings Lowell Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Heslin, Thomas

    2014-01-31

    The City of Lowell set four goals at the beginning of the Better Buildings Neighborhood Program: 1. Improve the Downtown Historic Park District’s Carbon Footprint 2. Develop a sustainable and replicable model for energy efficiency in historic buildings 3. Create and retain jobs 4. Promote multi-stakeholder partnerships The City of Lowell, MA was awarded $5 million in May 2010 to conduct energy efficiency retrofits within the downtown National Historical Park (NHP). The City’s target was to complete retrofits in 200,000 square feet of commercial space and create 280 jobs, while adhering to the strict historical preservation regulations that govern the NHP. The development of a model for energy efficiency in historic buildings was successfully accomplished. BetterBuildings Lowell’s success in energy efficiency in historic buildings was due to the simplicity of the program. We relied strongly on the replacement of antiquated HVAC systems and air sealing and a handful of talented energy auditors and contractors. BetterBuildings Lowell was unique for the Better Buildings Neighborhood Program because it was the only program that focused solely on commercial properties. BetterBuildings Lowell did target multi-family properties, which were reported as commercial, but the majority of the building types and uses were commercial. Property types targeted were restaurants, office buildings, museums, sections of larger buildings, mixed use buildings, and multifamily buildings. This unique fabric of building type and use allows for a deeper understanding to how different properties use energy. Because of the National Historical Park designation of downtown Lowell, being able to implement energy efficiency projects within a highly regulated historical district also provided valuable research and precedent proving energy efficiency projects can be successfully completed in historical districts and historical buildings. Our program was very successful in working with the local

  19. Links Related to the Indoor Air Quality Building Education and Assessment Model

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  20. Bibliography for the Indoor Air Quality Building Education and Assessment Model

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  1. Evaluation and simulation of event building techniques for a detector at the LHC

    CERN Document Server

    Spiwoks, R

    1995-01-01

    The main objectives of future experiments at the Large Hadron Collider are the search for the Higgs boson (or bosons), the verification of the Standard Model and the search beyond the Standard Model in a new energy range up to a few TeV. These experiments will have to cope with unprecedented high data rates and will need event building systems which can offer a bandwidth of 1 to 100GB/s and which can assemble events from 100 to 1000 readout memories at rates of 1 to 100kHz. This work investigates the feasibility of parallel event building sys- tems using commercially available high speed interconnects and switches. Studies are performed by building a small-scale prototype and by modelling this proto- type and realistic architectures with discrete-event simulations. The prototype is based on the HiPPI standard and uses commercially available VME-HiPPI interfaces and a HiPPI switch together with modular and scalable software. The setup operates successfully as a parallel event building system of limited size in...

  2. Thermal Convection Affects Shape Of Solid/Liquid Interface

    Science.gov (United States)

    Mennetrier, C.; Chopra, M. A.; Yao, M.; De Groh, H. C., III; Yeoh, G. H.; De Vahl Davis, G.; Leonardi, E.

    1994-01-01

    Report describes experimental and theoretical study of effect of thermal convection on shape of interface between solid and liquid succinonitrile, clear commercially available plastic, in Bridgman (directional-solidification) apparatus in vertical and horizontal orientations.

  3. [Technology transfer of building materials by ECOMAT

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-01

    This report discusses the plan for technology transfer of building materials developed by ECOMAT to the commercial private sector. Some of the materials are briefly discussed like foams, fiber reinforcement, fly ash development, and polymer fillers.

  4. Commercial thermal distribution systems, Final report for CIEE/CEC

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Tengfang; Bechu, Olivier; Carrie, Remi; Dickerhoff, Darryl; Fisk, William; Franconi, Ellen; Kristiansen, Oyvind; Levinson, Ronnen; McWilliams, Jennifer; Wang, Duo; Modera, Mark; Webster, Tom; Ring, Erik; Zhang, Qiang; Huizenga, Charlie; Bauman, Fred; Arens, Ed

    1999-12-01

    According to the California Energy Commission (CEC 1998a), California commercial buildings account for 35% of statewide electricity consumption, and 16% of statewide gas consumption. Space conditioning accounts for roughly 16,000 GWh of electricity and 800 million therms of natural gas annually, and the vast majority of this space conditioning energy passes through thermal distribution systems in these buildings. In addition, 8600 GWh per year is consumed by fans and pumps in commercial buildings, most of which is used to move the thermal energy through these systems. Research work at Lawrence Berkeley National Laboratory (LBNL) has been ongoing over the past five years to investigate the energy efficiency of these thermal distribution systems, and to explore possibilities for improving that energy efficiency. Based upon that work, annual savings estimates of 1 kWh/ft{sup 2} for light commercial buildings, and 1-2 kWh/ft{sup 2} in large commercial buildings have been developed for the particular aspects of thermal distribution system performance being addressed by this project. Those savings estimates, combined with a distribution of the building stock based upon an extensive stock characterization study (Modera et al. 1999a), and technical penetration estimates, translate into statewide saving potentials of 2000 GWh/year and 75 million thermal/year, as well as an electricity peak reduction potential of 0.7 GW. The overall goal of this research program is to provide new technology and application knowledge that will allow the design, construction, and energy services industries to reduce the energy waste associated with thermal distribution systems in California commercial buildings. The specific goals of the LBNL efforts over the past year were: (1) to advance the state of knowledge about system performance and energy losses in commercial-building thermal distribution systems; (2) to evaluate the potential of reducing thermal losses through duct sealing, duct

  5. Commercial thermal distribution systems, Final report for CIEE/CEC

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Tengfang; Bechu, Olivier; Carrie, Remi; Dickerhoff, Darryl; Fisk, William; Franconi, Ellen; Kristiansen, Oyvind; Levinson, Ronnen; McWilliams, Jennifer; Wang, Duo; Modera, Mark; Webster, Tom; Ring, Erik; Zhang, Qiang; Huizenga, Charlie; Bauman, Fred; Arens, Ed

    1999-12-01

    According to the California Energy Commission (CEC 1998a), California commercial buildings account for 35% of statewide electricity consumption, and 16% of statewide gas consumption. Space conditioning accounts for roughly 16,000 GWh of electricity and 800 million therms of natural gas annually, and the vast majority of this space conditioning energy passes through thermal distribution systems in these buildings. In addition, 8600 GWh per year is consumed by fans and pumps in commercial buildings, most of which is used to move the thermal energy through these systems. Research work at Lawrence Berkeley National Laboratory (LBNL) has been ongoing over the past five years to investigate the energy efficiency of these thermal distribution systems, and to explore possibilities for improving that energy efficiency. Based upon that work, annual savings estimates of 1 kWh/ft{sup 2} for light commercial buildings, and 1-2 kWh/ft{sup 2} in large commercial buildings have been developed for the particular aspects of thermal distribution system performance being addressed by this project. Those savings estimates, combined with a distribution of the building stock based upon an extensive stock characterization study (Modera et al. 1999a), and technical penetration estimates, translate into statewide saving potentials of 2000 GWh/year and 75 million thermal/year, as well as an electricity peak reduction potential of 0.7 GW. The overall goal of this research program is to provide new technology and application knowledge that will allow the design, construction, and energy services industries to reduce the energy waste associated with thermal distribution systems in California commercial buildings. The specific goals of the LBNL efforts over the past year were: (1) to advance the state of knowledge about system performance and energy losses in commercial-building thermal distribution systems; (2) to evaluate the potential of reducing thermal losses through duct sealing, duct

  6. Laboratory Building

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, Joshua M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    This report is an analysis of the means of egress and life safety requirements for the laboratory building. The building is located at Sandia National Laboratories (SNL) in Albuquerque, NM. The report includes a prescriptive-based analysis as well as a performance-based analysis. Following the analysis are appendices which contain maps of the laboratory building used throughout the analysis. The top of all the maps is assumed to be north.

  7. Laboratory Building.

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, Joshua M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    This report is an analysis of the means of egress and life safety requirements for the laboratory building. The building is located at Sandia National Laboratories (SNL) in Albuquerque, NM. The report includes a prescriptive-based analysis as well as a performance-based analysis. Following the analysis are appendices which contain maps of the laboratory building used throughout the analysis. The top of all the maps is assumed to be north.

  8. Study of Setting the Sky Lobby of Office Building in High Commercial Value Area-- Taking the Official Lobby of Angel in Bagualing, Shenzhen as an Example%高商业价值地段办公建筑设置空中大堂研究--以深圳八卦岭安吉尔办公大堂为例

    Institute of Scientific and Technical Information of China (English)

    何强; 陈佳伟; 陈林

    2014-01-01

    本文通过分析深圳海岸城办公建筑首层大堂与低层商业位置排斥的现象以及香港高商业价值地段办公建筑设置空中大堂的现象、原因及优缺点,对相似地段的深圳八卦岭安吉尔办公大堂的实例设计,探究了该模式的可行性。%This paper analyzed the phenomenon that the first floor office lobby of Shenzhen Coastal City rejected low-rise commercial and the phenomenon, reasons, advantages and disadvantages of set ing sky lobbies in lots of buildings that with high commercial value section in Hong Kong,then made study on the official lobby of Angel in Bagualing, Shenzhen as wel which is similar to the Hong Kong model, so as to make a preliminary study on the feasibility of the model.

  9. Concept of software interface for BCI systems

    Science.gov (United States)

    Svejda, Jaromir; Zak, Roman; Jasek, Roman

    2016-06-01

    Brain Computer Interface (BCI) technology is intended to control external system by brain activity. One of main part of such system is software interface, which carries about clear communication between brain and either computer or additional devices connected to computer. This paper is organized as follows. Firstly, current knowledge about human brain is briefly summarized to points out its complexity. Secondly, there is described a concept of BCI system, which is then used to build an architecture of proposed software interface. Finally, there are mentioned disadvantages of sensing technology discovered during sensing part of our research.

  10. 75 FR 53349 - NASA Advisory Council; Commercial Space Committee; Meeting

    Science.gov (United States)

    2010-08-31

    ... SPACE ADMINISTRATION NASA Advisory Council; Commercial Space Committee; Meeting AGENCY: National... announces a meeting of the Commercial Space Committee of the NASA Advisory Council. DATES: Tuesday September 14, 8 a.m. to 12 noon CDT. ADDRESSES: NASA Johnson Space Center, Building 1, Room 966. FOR...

  11. 77 FR 38678 - NASA Advisory Council; Commercial Space Committee; Meeting

    Science.gov (United States)

    2012-06-28

    ... SPACE ADMINISTRATION NASA Advisory Council; Commercial Space Committee; Meeting AGENCY: National... (NASA) announces a meeting of the Commercial Space Committee of the NASA Advisory Council (NAC). This.... ] ADDRESSES: NASA Goddard Space Flight Center (GSFC), Building 1, Room E100B, 8800 Greenbelt Road, Greenbelt...

  12. Specifying a green building

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, F.; McGregor, A. [Ove Arup and Partners, (United States)

    1998-11-01

    The concept of a `green` building is defined as a building that works with, rather than in spite of, the local climate to minimize fossil fuel consumption. It minimizes water consumption and waste. It uses construction materials that have a long life, are non-toxic, and which require minimum energy to produce, deliver to the building site and install. It is sufficiently flexible to permit successive changes without major construction work. With this definition as the background, this paper concentrates on the reduction of fossil fuel energy consumption in commercial buildings, and the various means available to achieve it, such as natural ventilation, thermal storage, control of solar gain, maximizing the use of daylight for illumination, and passive and active solar energy collection. Also discussed are some of the reasons why some buildings fail to satisfy owners and occupants. A strategy involving performance-based contracting, elements of value engineering and occupant education to assure energy efficiency and owner/occupants satisfaction is presented. 15 refs.

  13. Intelligent Buildings and pervasive computing

    DEFF Research Database (Denmark)

    Grønbæk, Kaj; Kyng, Morten; Krogh, Peter Gall

    2001-01-01

    Intelligent Buildings have been the subject of research and commercial interest for more than two decades. The different perspectives range from monitoring and controlling energy consumption over interactive rooms supporting work in offices and leisure in the home, to buildings providing...... information to by-passers in plazas and urban environments. This paper puts forward the hypothesis that the coming decade will witness a dramatic increase in both quality and quantity of intelligent buildings due to the emerging field of pervasive computing: the next generation computing environments where...

  14. Commercial Technology at the Tactical Edge

    Science.gov (United States)

    2013-06-01

    be encrypted with common methods, such as AES, since by the time an adversary decrypted the message, it would have little value. Another aspect of...Portability App Management App ecosystem 6 Hardened Smartphones, Tablets Sample Military Features -Ruggedized -Tactical Radio Interface - Encryption ... app stores, and new generations of cellular networks. Due to the initiatives of individual soldiers, commercial devices on the front lines are already

  15. Abating Earthquake Effects on Buildings by Active Slip Brace Devices

    Directory of Open Access Journals (Sweden)

    Zekai Akbay

    1995-01-01

    Full Text Available A hybrid control system for reducing building vibration under a spectrum of earthquake load amplitudes is presented. The hybrid control is accomplished by an energy dissipation device called the active slip brace device (ASBD. The hybrid control system uses the ASBD to regulate the energy dissipation characteristics of the building during its response to earthquakes by utilizing active control principles. The ASBD consists of a Coulomb friction interface with a clamping mechanism on the interface. The clamping force on the friction interface is altered at short time intervals during building vibration. Computer simulations of building response with and without ASBD are compared.

  16. Building Languages

    Science.gov (United States)

    ... Training Manually Coded English (MCE) Natural Gestures Speech Speech Reading (Lip Reading) Even though American Sign Language (ASL) is not a building block, it is sometimes used together with one or more building blocks. Close Information For... Media Policy Makers File Formats Help: How do I view ...

  17. Building Procurement

    DEFF Research Database (Denmark)

    Andersson, Niclas

    2007-01-01

    ‘The procurement of construction work is complex, and a successful outcome frequently elusive’. With this opening phrase of the book, the authors take on the challenging job of explaining the complexity of building procurement. Even though building procurement systems are, and will remain, comple...

  18. Commercialization of space

    Science.gov (United States)

    Rose, James T.; Stone, Barbara A.

    1988-01-01

    Space-commercialization activities are grouped into five categories: private sector development from existing technology for private sector use; pure privatization; private sector development for U.S. government use; private sector development from novel technology for private sector use; and, finally, full commercialization. The commercialization of space categories is defined, and the key issues in each are highlighted. A description of key NASA actions is included for each category. It is concluded that NASA and other government agency involvement is a common thread across the spectrum of space commercialization activities.

  19. NEBULAS A High Performance Data-Driven Event-Building Architecture based on an Asynchronous Self-Routing Packet-Switching Network

    CERN Multimedia

    Costa, M; Letheren, M; Djidi, K; Gustafsson, L; Lazraq, T; Minerskjold, M; Tenhunen, H; Manabe, A; Nomachi, M; Watase, Y

    2002-01-01

    RD31 : The project is evaluating a new approach to event building for level-two and level-three processor farms at high rate experiments. It is based on the use of commercial switching fabrics to replace the traditional bus-based architectures used in most previous data acquisition sytems. Switching fabrics permit the construction of parallel, expandable, hardware-driven event builders that can deliver higher aggregate throughput than the bus-based architectures. A standard industrial switching fabric technology is being evaluated. It is based on Asynchronous Transfer Mode (ATM) packet-switching network technology. Commercial, expandable ATM switching fabrics and processor interfaces, now being developed for the future Broadband ISDN infrastructure, could form the basis of an implementation. The goals of the project are to demonstrate the viability of this approach, to evaluate the trade-offs involved in make versus buy options, to study the interfacing of the physics frontend data buffers to such a fabric, a...

  20. Using Vim as User Interface for Your Applications

    CERN Document Server

    CERN. Geneva

    2017-01-01

    The Vim editor offers one of the cleverest user interfaces. It's why many developers write programs with vi keyboard bindings. Now, imagine how powerful it gets to build applications literally on top of Vim itself.