WorldWideScience

Sample records for column inverse gas

  1. Phase Equilibrium and Diffusion of Solvents in Polybutadiene: A Capillary-Column Inverse Gas Chromatography Study

    NARCIS (Netherlands)

    Cai, W.D.; Ramesh, N.; Tihminlioglu, F.; Danner, R.P.; Duda, J.L.; de Haan, A.B.

    2002-01-01

    The capillary-column inverse gas chromatography method was used to measure the diffusion and partition coefficients of ethylbenzene, styrene, and acrylonitrile in polybutadiene (PBD) at infinite dilution of the solvents. Experiments were performed over a temperature range of 50-125 °C. At

  2. TCAP HYDROGEN ISOTOPE SEPARATION USING PALLADIUM AND INVERSE COLUMNS

    Energy Technology Data Exchange (ETDEWEB)

    Heung, L.; Sessions, H.; Xiao, S.

    2010-08-31

    The Thermal Cycling Absorption Process (TCAP) was further studied with a new configuration. Previous configuration used a palladium packed column and a plug flow reverser (PFR). This new configuration uses an inverse column to replace the PFR. The goal was to further improve performance. Both configurations were experimentally tested. The results showed that the new configuration increased the throughput by a factor of more than 2.

  3. Circulation in gas-slurry column reactors

    Energy Technology Data Exchange (ETDEWEB)

    Clark, N.; Kuhlman, J.; Celik, I.; Gross, R.; Nebiolo, E.; Wang, Yi-Zun.

    1990-08-15

    Circulation in bubble columns, such as those used in fischer-tropsch synthesis, detracts from their performance in that gas is carried on average more rapidly through the column, and the residence time distribution of the gas in the column is widened. Both of these factors influence mass-transfer operations in bubble columns. Circulation prediction and measurement has been undertaken using probes, one-dimensional models, laser Doppler velocimetry, and numerical modeling. Local void fraction was measured using resistance probes and a newly developed approach to determining air/water threshold voltage for the probe. A tall column of eight inch diameter was constructed of Plexiglas and the distributor plate was manufactured to distribute air evenly through the base of the column. Data were gathered throughout the volume at three different gas throughputs. Bubble velocities proved difficult to measure using twin probes with cross-correlation because of radial bubble movement. A series of three-dimensional mean and RMS bubble and liquid velocity measurements were also obtained for a turbulent flow in a laboratory model of a bubble column. These measurements have been made using a three-component laser Doppler velocimeter (LDV), to determine velocity distributions non-intrusively. Finally, the gas-liquid flow inside a vertically situated circular isothermal column reactor was simulated numerically. 74 refs., 170 figs., 5 tabs.

  4. Non-planar microfabricated gas chromatography column

    Science.gov (United States)

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  5. Axial and Radial Gas Holdup in Bubble Column Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Wagh, Sameer M.; Ansari, Mohashin E Alan; Kene, Pragati T. [RTMNU Nagpur, Nagpur (India)

    2014-06-15

    Bubble column reactors are considered the reactor of choice for numerous applications including oxidation, hydrogenation, waste water treatment, and Fischer-Tropsch (FT) synthesis. They are widely used in a variety of industrial applications for carrying out gas-liquid and gas-liquid-solid reactions. In this paper, the computational fluid dynamics (CFD) model is used for predicting the gas holdup and its distribution along radial and axial direction are presented. Gas holdup increases linearly with increase in gas velocity. Gas bubbles tends to concentrate more towards the center of the column and follows a wavy path.

  6. Insights into Tikhonov regularization: application to trace gas column retrieval and the efficient calculation of total column averaging kernels

    Directory of Open Access Journals (Sweden)

    T. Borsdorff

    2014-02-01

    Full Text Available Insights are given into Tikhonov regularization and its application to the retrieval of vertical column densities of atmospheric trace gases from remote sensing measurements. The study builds upon the equivalence of the least-squares profile-scaling approach and Tikhonov regularization method of the first kind with an infinite regularization strength. Here, the vertical profile is expressed relative to a reference profile. On the basis of this, we propose a new algorithm as an extension of the least-squares profile scaling which permits the calculation of total column averaging kernels on arbitrary vertical grids using an analytic expression. Moreover, we discuss the effective null space of the retrieval, which comprises those parts of a vertical trace gas distribution which cannot be inferred from the measurements. Numerically the algorithm can be implemented in a robust and efficient manner. In particular for operational data processing with challenging demands on processing time, the proposed inversion method in combination with highly efficient forward models is an asset. For demonstration purposes, we apply the algorithm to CO column retrieval from simulated measurements in the 2.3 μm spectral region and to O3 column retrieval from the UV. These represent ideal measurements of a series of spaceborne spectrometers such as SCIAMACHY, TROPOMI, GOME, and GOME-2. For both spectral ranges, we consider clear-sky and cloudy scenes where clouds are modelled as an elevated Lambertian surface. Here, the smoothing error for the clear-sky and cloudy atmosphere is significant and reaches several percent, depending on the reference profile which is used for scaling. This underlines the importance of the column averaging kernel for a proper interpretation of retrieved column densities. Furthermore, we show that the smoothing due to regularization can be underestimated by calculating the column averaging kernel on a too coarse vertical grid. For both

  7. Fluid dynamics of gas-liquid bubble columns

    NARCIS (Netherlands)

    Delnoij, E.

    1999-01-01

    Gas-liquid bubble columns are used extensively in the process industries. The gas-liquid twophase flow prevailing in this type of process equipment is extremely complex, inherently unsteady and dominated by phenomena with widely varying time- and length-scales. it is for this reason that many

  8. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  9. Design, testing, and simulation of microscale gas chromatography columns

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, M.L.; Kottenstette, R.; Matzke, C.M.; Frye-Mason, G.C.; Shollenberger, K.A.; Adkins, D.R.; Wong, C.C.

    1998-08-01

    A microscale gas chromatography column is one component in a microscale chemistry laboratory for detecting chemical agents. Several columns were fabricated using the Bosch etch process which allows deep, high aspect ratio channels of rectangular cross-section. A design tool, based on analytical models, was developed to evaluate the effects of operating conditions and column specifications on separation resolution and time. The effects of slip flow, channel configuration, and cross-sectional shape were included to evaluate the differences between conventional round, straight columns and the microscale rectangular, spiral columns. Experimental data were obtained and compared with the predicted flowrates and theoretical number of plates. The design tool was then employed to select more optimum channel dimensions and operating conditions for high resolution separations.

  10. Completing electron scattering studies with the inert gas column:e - Rn scattering and Ionization

    CERN Document Server

    Joshi, Foram M; Chaudhari, Asha S; Modi, Hitesh S; Pindaria, Manish J

    2016-01-01

    Interest in the inert or noble- gas atoms in general arises because they are ideal as test systems for various theoretical models of electron scattering and also since their interaction processes serve as reference for the determination of instrumental responses in electron scattering experiments. The ionization cross section data of ground state inert gas atoms He through Xe are considered to be benchmark data. Our aim in this paper is to provide theoretical results on electron scattering with Radon atoms, as it would complete the studies on the entire inert gas column. That is possible with this particular column only, in view of the preceding literature on He through Xe . Inert gas radon is radioactive, and would be a difficult target for electron scattering experiments. In the present calculations, the complications arising from radioactivity are not considered. We provide hitherto unavailable cross sections on atomic radon, and also provide opportunity of the comparison of electron impact cross sections ...

  11. Methane gas seepage - Disregard of significant water column filter processes?

    Science.gov (United States)

    Schneider von Deimling, Jens; Schmale, Oliver

    2016-04-01

    Marine methane seepage represents a potential contributor for greenhouse gas in the atmosphere and is discussed as a driver for climate change. The ultimate question is how much methane is released from the seafloor on a global scale and what fraction may reach the atmosphere? Dissolved fluxes from methane seepage sites on the seabed were found to be very efficiently reduced by benthic microbial oxidation, whereas transport of free gas bubbles from the seabed is considered to bypass the effective benthic methane filter. Numerical models are available today to predict the fate of such methane gas bubble release to the water column in regard to gas exchange with the ambient water column, respective bubble lifetime and rise height. However, the fate of rising gas bubbles and dissolved methane in the water column is not only governed by dissolution, but is also affected by lateral oceanographic currents and vertical bubble-induced upwelling, microbial oxidation, and physico-chemical processes that remain poorly understood so far. According to this gap of knowledge we present data from two study sites - the anthropogenic North Sea 22/4b Blowout and the natural Coal Oil point seeps - to shed light into two new processes gathered with hydro-acoustic multibeam water column imaging and microbial investigations. The newly discovered processes are hereafter termed Spiral Vortex and Bubble Transport Mechanism. Spiral Vortex describes the evolution of a complex vortical fluid motion of a bubble plume in the wake of an intense gas release site (Blowout, North Sea). It appears very likely that it dramatically changes the dissolution kinetics of the seep gas bubbles. Bubble Transport Mechanism prescribes the transport of sediment-hosted bacteria into the water column via rising gas bubbles. Both processes act as filter mechanisms in regard to vertical transport of seep related methane, but have not been considered before. Spiral Vortex and Bubble Transport Mechanism represent the

  12. Population Inversion and Gain Measurements for Soft X-Ray Laser Development in a Magnetically Confined Plasma Column.

    Science.gov (United States)

    1985-09-01

    INVERSION AND GAIN MEASUREMENTS FOR ’I SOFT X-RAY LASER DEVELOPMENT IN A MAGNET ICALLY CONFINED PLASMA COLUMN" For the Period: Nov. 1, 1983 t hr u Sept...proposal to AFOSR entitled "Population Inversion and Gain Measurements for X-Ray Laser Development in Magnetically Confined Plasma Column," Princeton, March...I* INTRODUCTION Extensive research on x-ray laser development has provided a number of interesting results for different schemes, e.g. recombination

  13. Combinatorial Algorithms for Computing Column Space Bases ThatHave Sparse Inverses

    Energy Technology Data Exchange (ETDEWEB)

    Pinar, Ali; Chow, Edmond; Pothen, Alex

    2005-03-18

    This paper presents a combinatorial study on the problem ofconstructing a sparse basis forthe null-space of a sparse, underdetermined, full rank matrix, A. Such a null-space is suitable forsolving solving many saddle point problems. Our approach is to form acolumn space basis of A that has a sparse inverse, by selecting suitablecolumns of A. This basis is then used to form a sparse null-space basisin fundamental form. We investigate three different algorithms forcomputing the column space basis: Two greedy approaches that rely onmatching, and a third employing a divide and conquer strategy implementedwith hypergraph partitioning followed by the greedy approach. We alsodiscuss the complexity of selecting a column basis when it is known thata block diagonal basis exists with a small given block size.

  14. Sol-gel multicapillary columns for gas-solid chromatography.

    Science.gov (United States)

    Sidelnikov, Vladimir N; Patrushev, Yuri V; Belov, Yuri P

    2006-01-06

    In this work, we report the method for the preparation of multicapillary columns (MCCs) for gas-solid chromatography. The porous layer adsorbent is formed on capillary walls by the hydrolysis of aluminum alkoxide in the presence of polypropylene glycol (PPG) and HCl. Porosity and selectivity of the adsorbent depend on reaction conditions and the concentration of PPG. Sol-gel MCCs are well suited for high-speed chromatographic analysis of light hydrocarbons by gas-solid chromatography. Nine-component mixtures of C1-C4 hydrocarbons are separated within 8-12 s. The efficiency of 25-30 cm long alumina sol-gel MCCs consisting of approximately 1400 capillaries of 40 microm diameter is up to 2500-3000 theoretical plates.

  15. Investigating the constraint imposed by column averaged PBL CO2 data within an atmospheric inversion framework

    Science.gov (United States)

    Schuh, A. E.; Kawa, S. R.; Denning, A. S.; Baker, D. F.; Ramanathan, A. K.

    2014-12-01

    It was initially hoped that the proposed Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) NASA mission could rectify diurnal fluxes through it's ability to measure during both days and nights. However, initial simulation results (Kawa et al 2010) showed limited skill at identifying diurnal differences in fluxes. We investigate the possibility of (1) supplementing ASCENDS with well chosen in-situ surface sites and/or (2) adding distinct column measurements for the PBL and free troposphere into the inversion framework to determine the impact on recovering net ecosystem exchange (NEE), as well as distinct gross primary production (GPP) and respiration fluxes. In particular, we run forward simulations and inversions with distinct respiration and GPP fluxes calculated from the SiB model (Baker et al 2008) and test the ability of an EnKF based inversion framework to recover a hypothetical tropical CO2 fertilization effect resulting in enhanced GPP. Baker, I. T.; Prihodko, L.; Denning, A. S.; Goulden, M.; Miller, S. & da Rocha, H. R. (2008), 'Seasonal drought stress in the Amazon: Reconciling 3 models and observations', Journal of Geophysical Research 113. Kawa, S. R.; MAO, J.; ABSHIRE, J. B.; J., C. G.; SUN, X. & WEAVER, C. J. (2010), 'Simulation studies for a space-based CO2 lidar mission.', Tellus B 62, 759-769.

  16. Investigating Interphase Development in Woodpolymer Composites by Inverse Gas Chromatography

    Science.gov (United States)

    Timothy G. Rials; John Simonsen

    2000-01-01

    The influence of secondary interactions on the development of interfacial structure in composites of wood and amorphous thermoplastic polymers is not well understood. This study used inverse gas chromatography to investigate the effect of different polymers on the surface energy of partially or fully coated white pine wood meal. In this way, the development of the...

  17. High-dimensional Sparse Precision Matrix Estimation via Sparse Column Inverse Operator

    CERN Document Server

    Liu, Weidong

    2012-01-01

    This paper proposes a new method for estimating sparse precision matrices in the high dimensional setting. This procedure applies a novel Sparse Column-wise Inverse Operator (SCIO) to modified sample covariance matrices. We establish the convergence rates of this procedure under various matrix norms. Under the Frobenius norm loss, we prove theoretical guarantees on using cross validation to pick data-driven tunning parameters. Another important advantage of this estimator is its efficient computation for large-scale problems, using a path-following coordinate descent algorithm we provide. Numerical merits of our estimator are also illustrated using simulated and real datasets. In particular, this method is found to perform favorably on analyzing an HIV brain tissue dataset and an ADHD resting fMRI dataset.

  18. Study of Differential Column Measurements for Urban Greenhouse Gas Emission Monitoring

    Science.gov (United States)

    Chen, Jia; Hedelius, Jacob K.; Viatte, Camille; Jones, Taylor; Franklin, Jonathan E.; Parker, Harrison; Wennberg, Paul O.; Gottlieb, Elaine W.; Dubey, Manvendra K.; Wofsy, Steven C.

    2016-04-01

    Urban areas are home to 54% of the total global population and account for ˜ 70% of total fossil fuel emissions. Accurate methods for measuring urban and regional scale carbon fluxes are required in order to design and implement policies for emissions reduction initiatives. In this paper, we demonstrate novel applications of compact solar-tracking Fourier transform spectrometers (Bruker EM27/SUN) for differential measurements of the column-averaged dry-air mole fractions (DMFs) of CH4 and CO2 within urban areas. Our differential column method uses at least two spectrometers to make simultaneous measurements of CO2, CH4 and O2 column number densities. We then compute the column-averaged DMFs XG for a gas G and the differences ΔXG between downwind and upwind stations. By accurately measuring the small differences in integrated column amounts across local and regional sources, we directly observe the mass loading of the atmosphere due to the influence of emissions in the intervening locale. The inference of the source strength is much more direct than inversion modeling using only surface concentrations, and less subject to errors associated with modeling small-scale transport phenomena. We characterize the differential sensor system using Allan variance analysis and show that the differential column measurement has a precision of 0.01% for XCO2 and XCH4 using an optimum integration time of 10 min, which corresponds to standard deviations of 0.04 ppm, and 0.2 ppb, respectively. The sensor system is very stable over time and after relocation across the contiguous US, i.e. the scaling factors between the two Harvard EM27/SUNs and the measured instrument line function parameters are consistent. We use the differential column measurements to determine the emission of an area source. We measure the downwind minus upwind column gradient ΔXCH4 (˜ 2 ppb, 0.1%) across dairy farms in the Chino California area, and input the data to a simple column model for comparison with

  19. CFD Analysis of Gas Distributor in Packed Column--Prediction of Gas Flow and Effect of Tower Internals Geometry Structure

    Institute of Scientific and Technical Information of China (English)

    张吕鸿; 周海鹰; 李鑫钢; 杜玉萍

    2004-01-01

    Computational fluid dynamics (CFD) simulations were carried out on the gas flow patterns of twin-tangential annular deflector gas distributor in the absence of liquid flow in a packed column (6.4 m in diameter), and the gas flow field in the column was presented close to reality on the whole. Furthermore, after ame-lioration of this gas distributor frame, turbulence energy and turbulence energy dissipation rate were both decreased greatly.Simulation results showed that the flow pattern and the distribution of gas flow were strongly affected by the column bottom frame; the proper column bottom frame could decrease the flow pressure drop greatly. Multifold factors, such as the column bottom geometry structure and distributor structure which affects the distribution capacity, must be considered.

  20. Development of an Exhaled Breath Monitoring System with Semiconductive Gas Sensors, a Gas Condenser Unit, and Gas Chromatograph Columns

    Directory of Open Access Journals (Sweden)

    Toshio Itoh

    2016-11-01

    Full Text Available Various volatile organic compounds (VOCs in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls, and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls. The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis.

  1. Development of an Exhaled Breath Monitoring System with Semiconductive Gas Sensors, a Gas Condenser Unit, and Gas Chromatograph Columns.

    Science.gov (United States)

    Itoh, Toshio; Miwa, Toshio; Tsuruta, Akihiro; Akamatsu, Takafumi; Izu, Noriya; Shin, Woosuck; Park, Jangchul; Hida, Toyoaki; Eda, Takeshi; Setoguchi, Yasuhiro

    2016-11-10

    Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis.

  2. On the statistical optimality of CO2 atmospheric inversions assimilating CO2 column retrievals

    Directory of Open Access Journals (Sweden)

    F. Chevallier

    2015-04-01

    Full Text Available The extending archive of the Greenhouse Gases Observing SATellite (GOSAT measurements (now covering about six years allows increasingly robust statistics to be computed, that document the performance of the corresponding retrievals of the column-average dry air-mole fraction of CO2 (XCO2. Here, we compare a model simulation constrained by surface air-sample measurements with one of the GOSAT retrieval products (NASA's ACOS. The retrieval-minus-model differences result from various error sources, both in the retrievals and in the simulation: we discuss the plausibility of the origin of the major patterns. We find systematic retrieval errors over the dark surfaces of high-latitude lands and over African savannahs. More importantly, we also find a systematic over-fit of the GOSAT radiances by the retrievals over land for the high-gain detector mode, which is the usual observation mode. The over-fit is partially compensated by the retrieval bias-correction. These issues are likely common to other retrieval products and may explain some of the surprising and inconsistent CO2 atmospheric inversion results obtained with the existing GOSAT retrieval products. We suggest that reducing the observation weight in the retrieval schemes (for instance so that retrieval increments to the retrieval prior values are halved for the studied retrieval product would significantly improve the retrieval quality and reduce the need for (or at least reduce the complexity of ad-hoc retrieval bias correction. More generally, we demonstrate that atmospheric inversions cannot be rigorously optimal when assimilating XCO2 retrievals, even with averaging kernels.

  3. Technical Note: Detection of gas bubble leakage via correlation of water column multibeam images

    Directory of Open Access Journals (Sweden)

    J. Schneider von Deimling

    2012-03-01

    Full Text Available Hydroacoustic detection of natural gas release from the seafloor has been conducted in the past by using singlebeam echosounders. In contrast, modern multibeam swath mapping systems allow much wider coverage, higher resolution, and offer 3-D spatial correlation. Up to the present, the extremely high data rate hampers water column backscatter investigations and more sophisticated visualization and processing techniques are needed. Here, we present water column backscatter data acquired with a 50 kHz prototype multibeam system over a period of 75 seconds. Display types are of swath-images as well as of a "re-sorted" singlebeam presentation. Thus, individual and/or groups of gas bubbles rising from the 24 m deep seafloor clearly emerge in the acoustic images, making it possible to estimate rise velocities. A sophisticated processing scheme is introduced to identify those rising gas bubbles in the hydroacoustic data. We apply a cross-correlation technique adapted from particle imaging velocimetry (PIV to the acoustic backscatter images. Temporal and spatial drift patterns of the bubbles are assessed and are shown to match very well to measured and theoretical rise patterns. The application of this processing to our field data gives clear results with respect to unambiguous bubble detection and remote bubble rise velocimetry. The method can identify and exclude the main source of misinterpretations, i.e. fish-mediated echoes. Although image-based cross-correlation techniques are well known in the field of fluid mechanics for high resolution and non-inversive current flow field analysis, we present the first application of this technique as an acoustic bubble detector.

  4. Characterization of solute transport parameters in leach ore:inverse modeling based on column experiments

    Institute of Scientific and Technical Information of China (English)

    Sheng PENG

    2009-01-01

    Heap leaching is essentially a process in which metals are extracted from mine ores with lixiant. For a better understanding and modeling of this process, solute transport parameters are required to characterize the solute transport system of the leach heap. For porous media like leach ores, which contain substantial gravelly particles and have a broad range of particle size distributions, traditional small-scale laboratory experimental apparatus is not appropriate. In this paper, a 2.44m long, 0.3 m inner diameter column was used for tracer test with boron as the tracer. Tracer tests were conducted for 2 bulk densities (1.92 and 1.62g/cm3) and 2 irrigation rates (2 and 5 L/(mE. h-i)). Inverse modeling with two-region transport model using computer code CXTFIT was conducted based on the measured breakthrough curves to estimate the transport parameters. Fitting was focused on three parameters: dispersion coefficient D, partition coefficient r, and mass transfer coefficient ω. The results turned out to fall within reasonable ranges. Sensitivity analysis was conducted for the three parameters and showed that the order of sensitivity is β > ω > D. In addition, scaling of these parameters was discussed and applied to a real scale heap leach to predict the tracer breakthrough.

  5. Influence of structured packing on gas holdup in a three-phase bubble column

    DEFF Research Database (Denmark)

    Monsalvo, Matias Alfonso; Böhm, Ursula

    2007-01-01

    In this work, the influence of structured packing on gas holdup in gas-liquid-solid dispersions has been studied. The experiments were carried out in an empty column and in column containing structured packing operating under identical conditions. Glass beads and silicon carbide particles were used....... The influence of structured packing on the total gas holdup for different superficial gas velocities was found to be similar with and without suspended solids. Therefore, the results obtained in this work were analysed on the basis of correlations derived earlier for gas-liquid dispersions. Excepting...... as the solid material and the volumetric fraction of solids was varied from 0% to around 10%. The liquid viscosity was strongly modified using water, CMC solution and glycerol. The experimental results obtained with both columns were compared with previous results obtained in two-phase bubble columns...

  6. Surface characterization of polymers by inverse gas chromatography

    Directory of Open Access Journals (Sweden)

    ALEKSANDRA B. NASTASOVIC

    2007-04-01

    Full Text Available An inverse gas chromatographic (IGC study of the sorption properties of macroporous crosslinked poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate, PGME, and PGME modified with ethylene diamine, PGME-en, was presented. At infinite dilution, the thermodynamic parameters of adsorption, the dispersive components of the surface free energies, the acid/base constants and the interaction parameters for the initial and modified copolymer samples were investigated. The adsorption isotherms determined by IGC under conditions of finite surface coverage were used to estimate the surface area, the isosteric heat of adsorption and the adsorption energy distribution on the surface of the initial and modified copolymer samples.

  7. [Evaluation of inverse gas chromatography (IGC) methods to measure astragaloside solubility parameter from Buyang Huanwu decoction].

    Science.gov (United States)

    Tang, Yu; Hu, Chao; Liao, Qiong; Liu, Wen-long; Yang, Yan-tao; He, Hong; He, Fu-yuan

    2015-01-01

    The solubility parameter determination of astrageloside from Buyang Huanwu decoction with inverse gas chromatography (IGC) method evaluation was investigated in this paper. Di-n-octyl phthalate Kwai alternative sample was used to carry out methodological study. The accuracy of the measured correlation coefficient was 0.992 1. Experimental precision measured by IGC experiments showed that the results were accurate and reliable. The sample was uniformly coated on the surface of an inert carrier and N2 gas was carrier gas, a variety of polar solvents such as isopropanol, toluene, acetone, chloroform, cyclohexane as probes. TCD detector temperature was 150 degrees C, gas room temperature was 120 degrees C. Similar headspace method was used whichever over 1 μL gas into the GC measurement, Retention time t(R), t(0) and all the parameters of air and probes molecules within the column were tested. Astragaloside solubility parameter was (21.02 ± 2.4) [J x cm(-3)] ½, literature value was 19.24 [J x cm(-3)] ½, and relevant coefficient was 0.984 5. IGC method is effective and accurate to measure ingredients solubility parameter.

  8. Eulerian modeling of reactive gas-liquid flow in a bubble column

    NARCIS (Netherlands)

    Zhang, D.

    2007-01-01

    Despite the widespread application of bubble columns and intensive research efforts devoted to understand their complex behavior, detailed knowledge on the fluid flow, mass transfer and chemical reactions as well as their interactions is currently very limited. Gas-liquid flow in bubble column

  9. Planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as stationary phase

    Science.gov (United States)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.

    2016-04-01

    The high selectivity of the adsorption layer for low-boiling alkanes is shown, the separation factor (α) couple iso-butane / butane is 1.9 at a column temperature of 50 °C.The paper presents sorption and selective properties of planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as the stationary phase.

  10. Planar gas chromatography column on glass plate with nanodispersed silica as the stationary phase

    Science.gov (United States)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.; Agafonov, A. N.

    2016-04-01

    The paper presents the GC column in the plane of the glass plate with the adsorption layer nanodispersed silica. Created gas chromatographic column allows to separate a mixture of five alkanes from pentane to nonane in isothermal (90 ° C) mode less than one minute.

  11. Eulerian modeling of reactive gas-liquid flow in a bubble column

    NARCIS (Netherlands)

    Zhang, Dongsheng

    2007-01-01

    Despite the widespread application of bubble columns and intensive research efforts devoted to understand their complex behavior, detailed knowledge on the fluid flow, mass transfer and chemical reactions as well as their interactions is currently very limited. Gas-liquid flow in bubble column react

  12. Research on the Interaction of Hydrogen-Bond Acidic Polymer Sensitive Sensor Materials with Chemical Warfare Agents Simulants by Inverse Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2015-06-01

    Full Text Available Hydrogen-bond acidic polymers are important high affinity materials sensitive to organophosphates in the chemical warfare agent sensor detection process. Interactions between the sensor sensitive materials and chemical warfare agent simulants were studied by inverse gas chromatography. Hydrogen bonded acidic polymers, i.e., BSP3, were prepared for micro-packed columns to examine the interaction. DMMP (a nerve gas simulant and 2-CEES (a blister agent simulant were used as probes. Chemical and physical parameters such as heats of absorption and Henry constants of the polymers to DMMP and 2-CEES were determined by inverse gas chromatography. Details concerning absorption performance are also discussed in this paper.

  13. Research on the interaction of hydrogen-bond acidic polymer sensitive sensor materials with chemical warfare agents simulants by inverse gas chromatography.

    Science.gov (United States)

    Yang, Liu; Han, Qiang; Cao, Shuya; Huang, Feng; Qin, Molin; Guo, Chenghai; Ding, Mingyu

    2015-06-02

    Hydrogen-bond acidic polymers are important high affinity materials sensitive to organophosphates in the chemical warfare agent sensor detection process. Interactions between the sensor sensitive materials and chemical warfare agent simulants were studied by inverse gas chromatography. Hydrogen bonded acidic polymers, i.e., BSP3, were prepared for micro-packed columns to examine the interaction. DMMP (a nerve gas simulant) and 2-CEES (a blister agent simulant) were used as probes. Chemical and physical parameters such as heats of absorption and Henry constants of the polymers to DMMP and 2-CEES were determined by inverse gas chromatography. Details concerning absorption performance are also discussed in this paper.

  14. Analysis of the surface energy of pharmaceutical powders by inverse gas chromatography.

    Science.gov (United States)

    Grimsey, Ian M; Feeley, Jane C; York, Peter

    2002-02-01

    The behavior of pharmaceutical solids, during either processing or use, can be noticeably affected by the surface energetics of the constituent particles. Several techniques exist to measure the surface energy, for example, sessile drop, and dynamic contact angle measurements. Inverse gas chromatography (IGC) is an alternative technique where the powder surface is characterized by the retention behavior of minute quantities of well-characterized vapors that are injected into a column containing the material of interest. Recently published articles using IGC on pharmaceutical powders have ranged from linking surface energetic data with triboelectric charging to studying the effect of surface moisture on surface energetics. Molecular modelling has also recently been used to explore the links between IGC data and the structural and chemical factors that influence surface properties, thereby achieving predictive knowledge regarding powder behavior during processing. In this minireview, the reported applications of IGC in the analysis of pharmaceutical powders are summarized and the major findings highlighted.

  15. Inverse gas chromatographic study of the oxidation stability of lubricating base oils via solubility parameter calculations.

    Science.gov (United States)

    Moustafa, Nagy Emam; Eissa, Elham Ahmed

    2007-11-01

    The Flory-Huggins interaction parameter (chi1, 2(infinity)) and solubility parameter (delta2) and its hydrogen bonding sensing component (delta(h)) were determined using inverse gas chromatography (IGC). These parameters were successfully used in the probes of chemical changes that occur during the oxidation of naphthenic and paraffinic base oils in a GC column. Changes in chi1, 2(infinity) values reflect the different types of intermolecular interactions (dispersive, polar, hydrogen bonding) of the given lubricating base oil during oxidation. The obtained results showed that delta(h) component of solubility parameter is the most important parameter for probing the oxidative-chemical changes during the oxidation of given lubricating oils.

  16. Application of mass spectrometer-inverse gas chromatography to study polymer-solvent diffusivity and solubility.

    Science.gov (United States)

    Galdámez, J Román; Danner, Ronald P; Duda, J Larry

    2007-07-20

    The application of a mass spectrometer detector in capillary column inverse gas chromatography is shown to be a valuable tool in the measurement of diffusion and solubility in polymer-solvent systems. The component specific detector provides excellent results for binary polymer-solvent systems, but it is particularly valuable because it can be readily applied to multicomponent systems. Results for a number of infinitely dilute solvents in poly(vinyl acetate) (PVAc) are reported over a range of temperature from 60 to 150 degrees C. Results are also reported for finite concentrations of toluene and methanol in PVAc from 60 to 110 degrees C. Finally, the technique was applied to study the effect of finite concentrations of toluene on the diffusion coefficients of THF and cyclohexane in PVAc. The experimental data compare well with literature values for both infinite and finite concentrations, indicating that the experimental protocol described in this work is sound.

  17. Inverse modeling of GOSAT-retrieved ratios of total column CH4 and CO2 for 2009 and 2010

    NARCIS (Netherlands)

    Pandey, S.

    2016-01-01

    This study investigates the constraint provided by greenhouse gas measurements from space on surface fluxes. Imperfect knowledge of the light path through the atmosphere, arising from scattering by clouds and aerosols, can create biases in column measurements retrieved from space. To minimize the im

  18. Inverse modeling of GOSAT-retrieved ratios of total column CH4 and CO2 for 2009 and 2010

    NARCIS (Netherlands)

    Pandey, Sudhanshu; Houweling, Sander; Krol, Maarten; Aben, Ilse; Chevallier, Frédéric; Dlugokencky, Edward J.; Gatti, Luciana V.; Gloor, Emanuel; Miller, John B.; Detmers, Rob; Machida, Toshinobu; Röckmann, Thomas

    2016-01-01

    This study investigates the constraint provided by greenhouse gas measurements from space on surface fluxes. Imperfect knowledge of the light path through the atmosphere, arising from scattering by clouds and aerosols, can create biases in column measurements retrieved from space. To minimize the

  19. Surface Characterization of Glass Fiber by Inverse Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    HUANG Xiaohua; LI Bin; SHI Baoli; GUO Xuefei; JIA Lina

    2008-01-01

    The surface properties of glass fiber were quantificationally analyzed by inverse gas chromatography (IGC). Five n-alkanes (C6, C7, C8, C9, and C10) were chosen as apolar probes to characterize the dispersive component of surface free energy. Trichloromethane (CHCl3), acetone,and tetrahydrofuran (THF) were chosen as polar probes to detect the Lewis acid-base parameters. It is found that the dispersive components of free energy are 32.3, 30.5, 27.5, and 26.9 Mj/m2 at 70,80, 90, and 100 ℃, respectively. The Lewis acidic number Ka of the glass fiber is 0.512 4, and the basic number Kb is 2.862. The results mean the glass fiber is a Lewis basic material.

  20. Hansen solubility parameters for polyethylene glycols by inverse gas chromatography.

    Science.gov (United States)

    Adamska, Katarzyna; Voelkel, Adam

    2006-11-03

    Inverse gas chromatography (IGC) has been applied to determine solubility parameter and its components for nonionic surfactants--polyethylene glycols (PEG) of different molecular weight. Flory-Huggins interaction parameter (chi) and solubility parameter (delta(2)) were calculated according to DiPaola-Baranyi and Guillet method from experimentally collected retention data for the series of carefully selected test solutes. The Hansen's three-dimensional solubility parameters concept was applied to determine components (delta(d), delta(p), delta(h)) of corrected solubility parameter (delta(T)). The molecular weight and temperature of measurement influence the solubility parameter data, estimated from the slope, intercept and total solubility parameter. The solubility parameters calculated from the intercept are lower than those calculated from the slope. Temperature and structural dependences of the entopic factor (chi(S)) are presented and discussed.

  1. Evaluation of Gas Retention in Waste Simulants: Tall Column Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Shimskey, Rick W.; Denslow, Kayte M.; Powell, Michael R.; Boeringa, Gregory K.; Bontha, Jagannadha R.; Karri, Naveen K.; Fifield, Leonard S.; Tran, Diana N.; Sande, Susan; Heldebrant, David J.; Meacham, Joseph E.; Smet, Dave; Bryan, Wesley E.; Calmus, Ronald B.

    2014-05-16

    Gas generation in Hanford’s underground waste storage tanks can lead to gas accumulation within the layer of settled solids (sludge) at the tank bottom. The gas, which typically has hydrogen as the major component together with other flammable species, is formed principally by radiation-driven chemical reactions. Accumulation of these gases within the sludge in a waste tank is undesirable and limits the amount of tank volume for waste storage. Further, accumulation of large amounts of gas in the sludge may potentially result in an unacceptable release of the accumulated gas if the sludge-layer density is reduced to less than that of the overlying sludge or that of the supernatant liquid. Rapid release of large amounts of flammable gases could endanger personnel and equipment near the tank. For this reason, a thorough understanding of the circumstances that can lead to a potentially problematic gas accumulation in sludge layers is needed. To respond to this need, the Deep Sludge Gas Release Event Program (DSGREP) was commissioned to examine gas release behavior in sludges.

  2. Improved micromachined column design and fluidic interconnects for programmed high-temperature gas chromatography separations.

    Science.gov (United States)

    Gaddes, David; Westland, Jessica; Dorman, Frank L; Tadigadapa, Srinivas

    2014-07-01

    This work focuses on the development and experimental evaluation of micromachined chromatographic columns for use in a commercial gas chromatography (GC) system. A vespel/graphite ferrule based compression sealing technique is presented using which leak-proof fluidic interconnection between the inlet tubing and the microchannel was achieved. This sealing technique enabled separation at temperatures up to 350°C on a μGC column. This paper reports the first high-temperature separations in microfabricated chromatographic columns at these temperatures. A 2m microfabricated column using a double Archimedean spiral design with a square cross-section of 100μm×100μm has been developed using silicon microfabrication techniques. The microfabricated column was benchmarked against a 2m 100μm diameter commercial column and the performance between the two columns was evaluated in tests performed under identical conditions. High temperature separations of simulated distillation (ASTM2887) and polycyclic aromatic hydrocarbons (EPA8310) were performed using the μGC column in temperature programmed mode. The demonstrated μGC column along with the high temperature fixture offers one more solution toward potentially realizing a portable μGC device for the detection of semi-volatile environmental pollutants and explosives without the thermal limitations reported to date with μGC columns using epoxy based interconnect technology.

  3. Research on the Interaction of Hydrogen-Bond Acidic Polymer Sensitive Sensor Materials with Chemical Warfare Agents Simulants by Inverse Gas Chromatography

    OpenAIRE

    Liu Yang; Qiang Han; Shuya Cao; Feng Huang; Molin Qin; Chenghai Guo; Mingyu Ding

    2015-01-01

    Hydrogen-bond acidic polymers are important high affinity materials sensitive to organophosphates in the chemical warfare agent sensor detection process. Interactions between the sensor sensitive materials and chemical warfare agent simulants were studied by inverse gas chromatography. Hydrogen bonded acidic polymers, i.e., BSP3, were prepared for micro-packed columns to examine the interaction. DMMP (a nerve gas simulant) and 2-CEES (a blister agent simulant) were used as probes. Chemical an...

  4. A three-demensional CFD model for gas-liquid bubble columns.

    NARCIS (Netherlands)

    Delnoij, E.; Kuipers, J.A.M.; van Swaaij, Willibrordus Petrus Maria

    1999-01-01

    This paper discusses the development of a three-dimensional Euler¿Lagrange CFD model for a gas¿liquid bubble column. The model resolves the time-dependent, three-dimensional motion of small, spherical gas bubbles in a liquid. Our model incorporates all relevant forces acting on a bubble rising in a

  5. Gas-Liquid Mass Transfer in a Slurry Bubble Column Reactor under High Temperature and

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The gas-liquid mass transfer of H2 and CO in a high temperature and high-pressure three-phase slurry bubble column reactor is studied. The gas-liquid volumetric mass transfer coefficients κLα are obtained by measuring the dissolution rate of H2 and CO. The influences of the main operation conditions, such as temperature, pressure, superficial gas velocity and solid concentration, are studied systematically. Two empirical correlations are proposed to predict κLα values for H2 and CO in liquid paraffin/solid particles slurry bubble column reactors.

  6. Developing a Method for Resolving NOx Emission Inventory Biases Using Discrete Kalman Filter Inversion, Direct Sensitivities, and Satellite-Based Columns

    Science.gov (United States)

    An inverse method was developed to integrate satellite observations of atmospheric pollutant column concentrations and direct sensitivities predicted by a regional air quality model in order to discern biases in the emissions of the pollutant precursors.

  7. Experimental engineering section off-gas decontamination facility's fractionator column: installation and performance

    Energy Technology Data Exchange (ETDEWEB)

    Gilliam, T. M.; Fowler, V. L.; Inman, D. J.

    1978-03-01

    A detailed description of the third column recently installed in the Experimental Engineering Section Off-Gas Decontamination Facility (EES-ODF) is presented. The EES-ODF is being used to provide engineering-scale experiments (nominal gas and liquid flows of 5 scfm and 0.5 gpm, respectively) in the development of the Krypton Absorption in Liquid CO/sub 2/ (KALC) process. A detailed discussion of the column's construction is provided. This discussion includes the peripherals associated with the column, such as refrigeration, heat exchangers, instrumentation, etc. The compressibility of Goodloe packing (the packing in the other columns) and the possible reduced throughput due to this compression have revealed the desirablility of a random (i.e., noncompressible) packing. Toward this end, the third column is packed with a new random packing (PRO-PAK). A preliminary comparison between this packing and the woven wire mesh packing (Goodloe) used in the other two columns has been made. Experiments comparing the throughput capacity indicate that the PRO-PAK packing has approximately 60% the capacity of Goodloe for a CO/sub 2/ system. When used as a fractionator or stripper with the basic O/sub 2/-Kr-CO/sub 2/ KALC system, the PRO-PAK column produced HTU values less than or equal to the GOODLOE columns under similar operating conditions.

  8. Cross-column prediction of gas-chromatographic retention indices of saturated esters.

    Science.gov (United States)

    D'Archivio, Angelo Antonio; Maggi, Maria Anna; Ruggieri, Fabrizio

    2014-08-15

    We combine computational molecular descriptors and variables related with the gas-chromatographic stationary phase into a comprehensive model able to predict the retention of solutes in external columns. To explore the quality of various approaches based on alternative column descriptors, we analyse the Kováts retention indices (RIs) of 90 saturated esters collected with seven columns of different polarity (SE-30, OV-7, DC-710, OV-25, XE-60, OV-225 and Silar-5CP). Cross-column retention prediction is evaluated on an internal validation set consisting of data of 40 selected esters collected with each of the seven columns, sequentially excluded from calibration. The molecular descriptors are identified by a genetic algorithm variable selection method applied to a large set of non-empirical structural quantities aimed at finding the best multi-linear quantitative structure-retention relationship (QSRR) for the column OV-25 having intermediate polarity. To describe the columns, we consider the sum of the first five McReynolds phase constants and, alternatively, the coefficients of the corresponding QSRRs. Moreover, the mean RI value for the subset of esters used in QSRR calibration or RIs of a few selected compounds are used as column descriptors. For each combination of solute and column descriptors, the retention model is generated both by multi-linear regression and artificial neural network regression. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. On the use of satellite-derived CH4 : CO2 columns in a joint inversion of CH4 and CO2 fluxes

    NARCIS (Netherlands)

    Pandey, S.

    2015-01-01

    We present a method for assimilating total column CH4 : CO2 ratio measurements from satellites for inverse modeling of CH4 and CO2 fluxes using the variational approach. Unlike conventional approaches, in which retrieved CH4 : CO2 are multiplied by model-derived total column CO2 and only the resulti

  10. On the use of satellite-derived CH4 : CO2 columns in a joint inversion of CH4 and CO2 fluxes

    NARCIS (Netherlands)

    Pandey, S.

    2015-01-01

    We present a method for assimilating total column CH4 : CO2 ratio measurements from satellites for inverse modeling of CH4 and CO2 fluxes using the variational approach. Unlike conventional approaches, in which retrieved CH4 : CO2 are multiplied by model-derived total column CO2 and only the resulti

  11. Textural characterization of silica gel from adsorption columns of the natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Rockmann, Rico [Wilhelm Ostwald Inst. fuer Physikalische und Theoretische Chemie, Univ. Leipzig (Germany); Messow, Ulf [Univ. Leipzig (Germany); Kleinitz, Wolfram [Gaz de France Produktion Exploration Deutschland GmbH, Lingen (Ems) (Germany); Kalies, Grit [Inst. fuer Experimentelle Physik I, Univ. Leipzig (Germany)

    2008-12-15

    Commercial silica gel used in adsorption columns for the removal of natural gas liquids from a natural gas stream is analyzed in its textured parameters such as porosity, pore size distribution and surface area. The texture of the original material before application in adsorptions columns is compared with that of samples of material which had been in operation for almost seven years in natural gas adsorption columns. In order to obtain relevant structural information, different well-established experimental techniques are applied such as low-temperature adsorption volumetry, mercury intrusion and scanning electron microscopy. It is shown that experimental pore-size techniques are appropriate to characterize the adsorption capacity of a physical solvent and to obtain in this way information about the remaining efficiency of technical adsorber fillings. (orig.)

  12. Pressure Tuning of First Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Marriott, Philip J

    2016-09-20

    The experimental approach and mechanism of pressure tuning (PT) are introduced for the first stage of a comprehensive two-dimensional gas chromatography (GC × GC) separation. The PT-GC × GC system incorporates a first dimension ((1)D) coupled column ensemble comprising a pair of (1)D columns ((1)D1 and (1)D2) connected via a microfluidic splitter device, allowing variable decompression of carrier gas across each (1)D column, and a conventional (2)D narrow bore column. By variation of junction pressure between the (1)D1 and (1)D2 columns, tunable total (1)D retentions of analytes are readily derived. Separations of a standard mixture comprising a number of different chemical classes (including alkanes, monoaromatics, alcohols, aldehydes, ketones, and esters) and Australian tea tree oil (TTO) were studied as practical examples of the PT-GC × GC system application. This illustrated the change of analyte retention time with experimental conditions depending on void time and retention on the different columns. In addition to void time change, variation of carrier gas relative decompression in the (1)D ensemble leads to tunable contribution of the (1)D1/(1)D2 columns that changes apparent polarity and selectivity of the ensemble. The resulting changes in (1)D elution order further altered elution temperature and thus retention of each analyte on the (2)D column in temperature-programmed GC × GC. 2D orthogonality measurements were then conducted to evaluate overall separation performance under application of different (1)D junction pressure. As a result, distribution and selectivity of particular target compounds, monoterpenes, sesquiterpenes, and oxygenated terpenes in 2D space, and thus orthogonality, could be adequately tuned. This indicates the potential of PT-GC × GC to be applicable for practical sample separation and provides a general approach to tune selectivity of target compounds.

  13. Effective rates of heavy metal release from alkaline wastes--quantified by column outflow experiments and inverse simulations.

    Science.gov (United States)

    Wehrer, Markus; Totsche, Kai Uwe

    2008-10-23

    Column outflow experiments operated at steady state flow conditions do not allow the identification of rate limited release processes. This requires an alternative experimental methodology. In this study, the aim was to apply such a methodology in order to identify and quantify effective release rates of heavy metals from granular wastes. Column experiments were conducted with demolition waste and municipal waste incineration (MSWI) bottom ash using different flow velocities and multiple flow interruptions. The effluent was analyzed for heavy metals, DOC, electrical conductivity and pH. The breakthrough-curves were inversely modeled with a numerical code based on the advection-dispersion equation with first order mass-transfer and nonlinear interaction terms. Chromium, Copper, Nickel and Arsenic are usually released under non-equilibrium conditions. DOC might play a role as carrier for those trace metals. By inverse simulations, generally good model fits are derived. Although some parameters are correlated and some model deficiencies can be revealed, we are able to deduce physically reasonable release-mass-transfer time scales. Applying forward simulations, the parameter space with equifinal parameter sets was delineated. The results demonstrate that the presented experimental design is capable of identifying and quantifying non-equilibrium conditions. They show also that the possibility of rate limited release must not be neglected in release and transport studies involving inorganic contaminants.

  14. Building Generalized Inverses of Matrices Using Only Row and Column Operations

    Science.gov (United States)

    Stuart, Jeffrey

    2010-01-01

    Most students complete their first and only course in linear algebra with the understanding that a real, square matrix "A" has an inverse if and only if "rref"("A"), the reduced row echelon form of "A", is the identity matrix I[subscript n]. That is, if they apply elementary row operations via the Gauss-Jordan algorithm to the partitioned matrix…

  15. Building Generalized Inverses of Matrices Using Only Row and Column Operations

    Science.gov (United States)

    Stuart, Jeffrey

    2010-01-01

    Most students complete their first and only course in linear algebra with the understanding that a real, square matrix "A" has an inverse if and only if "rref"("A"), the reduced row echelon form of "A", is the identity matrix I[subscript n]. That is, if they apply elementary row operations via the Gauss-Jordan algorithm to the partitioned matrix…

  16. Flow of gas-liquid-solid system and its application in packed flotation column

    Institute of Scientific and Technical Information of China (English)

    丁一刚; 吴元欣; 李定或

    2002-01-01

    A packed flotation column, which is packed with multiple board ripple packings, was described. Based on comprehensive steady state models, chemical reactor developed previously in chemical engineering subjects, have been extended to packed flotation column for mineral separation. The experimental results verify that tanks in series model is better than axially-dispersed plug flow model to describe flow pattern in the collection zone of column by RTD (residence time distribution), and the error of experimental data and calculated data of both models are 0.07%~0.1% and 0.18%~0.45% respectively. And, RTD of gas phase was also considered, results also show that gas in the whole column appears plug flow. The cleaning process through adding wash water in froth zone of column was described, and the effect of superficial air velocity and superficial wash water velocity on the cleaning action of froth zone were discussed. Flotation experiment for single column was conducted for phosphate ores. The recovery for P2O5 was 85.8%, and the grade was 26.8%.

  17. Micro-fabricated packed gas chromatography column based on laser etching technology.

    Science.gov (United States)

    Sun, J H; Guan, F Y; Zhu, X F; Ning, Z W; Ma, T J; Liu, J H; Deng, T

    2016-01-15

    In this work, a micro packed gas chromatograph column integrated with a micro heater was fabricated by using laser etching technology (LET) for analyzing environmental gases. LET is a powerful tool to etch deep well-shaped channels on the glass wafer, and it is the most effective way to increase depth of channels. The fabricated packed GC column with a length of over 1.6m, to our best knowledge, which is the longest so far. In addition, the fabricated column with a rectangular cross section of 1.2mm (depth) × 0.6mm (width) has a large aspect ratio of 2:1. The results show that the fabricated packed column had a large sample capacity, achieved a separation efficiency of about 5800 plates/m and eluted highly symmetrical Gaussian peaks.

  18. Prediction of Gas Holdup in Bubble Columns Using Artificial Neural Network

    Institute of Scientific and Technical Information of China (English)

    吴元欣; 罗湘华; 陈启明; 李定或; 李世荣; M.H.Al-Dahhan; M.P.Dudukovic

    2003-01-01

    A new correlation for the prediction of gas hod up in bubble columns was proposed based on an extensive experimental database set up from the literature published over last 30 years .The updated estimation method relying on artificial neural network,dimensional analysis and phenomenological approaches was used and the model prediction agreed with the experimental data with average relative error less than 10%.

  19. The gas holdup in a multiphase reciprocating plate column filled with carboxymethylcellulose solutions

    Directory of Open Access Journals (Sweden)

    I. S. STAMENKOVIC

    2005-12-01

    Full Text Available Gas holdup was investigated in a gas–liquid and gas–liquid-solid reciprocating plate column (RPC under various operation conditions. Aqueous carboxymethylcellulose (sodium salt, CMC solutions were used as the liquid phase, the solid phase was spheres placed into interplate spaces, and the gas plase was air. The gas holdup in the RPC was influenced by: the vibration intensity, i.e., the power consumption, the superficial gas velocity, the solids content and the rheological properties of the liquid phase. The gas holdup increased with increasing vibration intensity and superficial gas velocity in both the two- and three-phase system. With increasing concentration of the CMC PP 50 solution (Newtonian fluid, the gas holdup decreased, because the coalescence of the bubbles was favored by the higher liquid viscosity. In the case of the CMC PP 200 solutions (non-Newtonian liquids, the gas holdup depends on the combined influence of the rheological properties of the liquid phase, the vibration intensity and the superficial gas velocity. The gas holdup in the three-phase systems was greater than that in the two-phase ones under the same operating conditions. Increasing the solids content has little influence on the gas holdup. The gas holdup was correlated with the power consumption (either the time-averaged or total power consuption and the superficial gas velocity.

  20. Operational trace gas column observations from GOME-2 on MetOp

    Science.gov (United States)

    Valks, Pieter; Hao, Nan; Pinardi, Gaia; Hedelt, Pascal; Liu, Song; Van Roozendael, Michel; De Smedt, Isabelle; Theys, Nicolas; Koukouli, MariLiza; Balis, Dimitris

    2017-04-01

    This contribution focuses on the operational GOME-2 trace gas column products developed in the framework of EUMETSAT's Satellite Application Facility on Atmospheric Composition Monitoring (AC-SAF). We present an overview of the retrieval algorithms for ozone, OClO, NO2, SO2 and formaldehyde, and we show examples of various applications such as air quality and climate monitoring, using observations from the GOME-2 instruments on MetOp-A and MetOp-B. Total ozone and the minor trace gas columns from GOME-2 are retrieved with the latest version 4.8 of the GOME Data Processor (GDP), which uses an optimized Differential Optical Absorption Spectroscopy (DOAS) algorithm, with air mass factor conversions based on the LIDORT model. Improved total and tropospheric NO2 columns are retrieved in the visible wavelength region between 425 and 497 nm. SO2 emissions from volcanic and anthropogenic sources can be measured by GOME-2 using the UV wavelength region around 320 nm. For formaldehyde, an optimal DOAS fitting window around 335 nm has been determined for GOME-2. The GOME-2 trace gas columns have reached the operational EUMETSAT product status, and are available to the users in near real time (within two hours after sensing by GOME-2). The use of trace gas observations from the GOME-2 instruments on MetOp-A and MetOp-B for air quality purposed will be illustrated, e.g. for South-East Asia and Europe. Furthermore, comparisons of the GOME-2 satellite observations with ground-based measurements will be shown. Finally, the use of GOME-2 trace-gas column data in the Copernicus Atmosphere Monitoring Service (CAMS) will be presented.

  1. Gas-Liquid flow characterization in bubble columns with various gas-liquid using electrical resistance tomography

    Science.gov (United States)

    Jin, Haibo; Yuhuan, Han; Suohe, Yang

    2009-02-01

    Electrical resistance tomography (ERT) is an advanced and new detecting technique that can measure and monitor the parameters of two-phase flow on line, such as gas-liquid bubble column. It is fit for the industrial process where the conductible medium serves as the disperse phase to present the key bubble flow characteristics in multi-phase medium. Radial variation of the gas holdup and mean holdups are investigated in a 0.160 m i. d. bubble column using ERT with two axial locations (Plane 1 and Plane 2). In all the experiments, air was used as the gas phase, tap water as liquid phase, and a series of experiments were done by adding KCl, ethanol, oil sodium, and glycerol to change liquid conductivity, liquid surface tension and viscosity. The superficial gas velocity was varied from 0.02 to 0.2 m/s. The effect of conductivity, surface tension, viscosity on the mean holdups and radial gas holdup distribution is discussed. The results showed that the gas holdup decrease with the increase of surface tension and increase with the increase of viscosity. Meanwhile, the settings of initial liquid conductivity slightly influence the gas holdup values, and the experimental data increases with the increase of the initial setting values in the same conditions.

  2. Gas-Liquid Mass Transfer Characteristics in a Gas-Liquid-Solid Bubble Column under Elevated Pressure and Temperature

    Institute of Scientific and Technical Information of China (English)

    Haibo Jin; Suohe Yang; Guangxiang He; Delin Liu; Zemin Tong; Jianhua Zhu

    2014-01-01

    abstract The volumetric mass transfer coefficient kLa of gases (H2, CO, CO2) and mass transfer coefficient kL on liquid par-affin side were studied using the dynamic absorption method in slurry bubble column reactors under elevated temperature and elevated pressure. Meanwhile, gas-holdup and gas-liquid interfacial area a were obtained. The effects of temperature, pressure, superficial gas velocity and solid concentration on the mass transfer coeffi-cient were discussed. Experimental results show that the gas-liquid volumetric mass transfer coefficient kLa and interfacial area a increased with the increase of pressure, temperature, and superficial gas velocity, and decreased with the slurry concentration. The mass transfer coefficient kL increased with increasing superficial gas velocity and temperature and decreased with higher slurry concentration, while it changed slightly with pressure. Ac-cording to analysis of experimental data, an empirical correlation is obtained to calculate the values of kLa for H2 (CO, CO2) in the gas-paraffin-quartz system in a bubble column under elevated temperature and elevated pressure.

  3. Characterization of gas transfer and mixing in a bubble column equipped with a rubber membrane diffuser

    Science.gov (United States)

    Poulsen; Iversen

    1998-06-20

    Gas transfer and mixing were characterized in a 32-L bubble column reactor equipped with a commercially available rubber membrane diffuser. The performance of the membrane diffuser indicates that the slits in the membrane are best described as holes with elastic lids, acting as valves cutting off bubbles from the gas stream. The membrane diffuser thus functions as a one-way valve preventing backflow of liquid. Our design of the bottom plate of the reactor enabled us to optimize the aeration by changing the tension of the membrane. We thereby achieved mass transfer coefficients higher than those previously reported in bubble columns. A strong dependence of mass transfer on gas holdup and bubble size was indicated by estimates based on these two variables. The microalga, Rhodomonas sp. , sensitive to chemical and physical stress, was maintained for 8 months in continuous culture with a productivity identical to cultures grown in stirred tank reactors. Copyright 1998 John Wiley & Sons, Inc.

  4. Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

    Energy Technology Data Exchange (ETDEWEB)

    Read, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sillerud, Colin Halliday [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

  5. An inverse gas chromatographic methodology for studying gas-liquid mass transfer.

    Science.gov (United States)

    Paloglou, A; Martakidis, K; Gavril, D

    2017-01-13

    A novel methodology of reversed flow inverse gas chromatography (RF-IGC) is presented. It permits the simultaneous determination of mass transfer coefficients across the gas liquid interface as well as the respective solubility parameters and thermodynamic functions of dissolution of gases into liquids. The standard deviation of the experimentally determined parameters is estimated for first time, which combined with the successful comparison of the values of the present parameters with other literature ones ascertain the reliability of the methodology. Another novelty of the present work is that the chromatographic sampling of the physicochemical phenomena is done without performing the usual flow reversals procedure. Vinyl chloride monomer's (VCM) interaction with various composition liquid foods: orange juice, milk and olive oil was used as model system. The present transfer rates are controlled by the gas film at lower temperatures, but at higher temperatures the resistances in both films tend to become equal. The found liquid diffusivity values express the total mass transfer from the gas phase into the liquid's bulk and they decrease with rising temperature, as the solubilities of gases in liquids do. Solubility, expressed by Henry's law constant and the mean values of interfacial thickness are of the same order of magnitude to literature ones. From the thermodynamic point of view, VCM dissolution in all liquids is accompanied by significant heat release and it is a slightly non-spontaneous process, near equilibrium, while the entropy change values are negative. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Controllable preparation of copper phthalocyanine single crystal nano column and its chlorine gas sensing properties

    Directory of Open Access Journals (Sweden)

    Jianhong Zhao

    2016-09-01

    Full Text Available The unsubstituted copper phthalocyanine (CuPc single crystal nano columns were fabricated for the first time as chlorine (Cl2 gas sensors in this paper. The nano columns of CuPc have been prepared on different substrates via template-free physical vapor deposition (PVD approach. The growth mechanism of CuPc nano column on quartz was explored and the same condition used on other substrates including glass, sapphire (C-plane, M-plane, R-plane, Si and SiO2/Si came to a same conclusion, which confirmed that the aligned growth of CuPc nano column is not substrate-dependent. And then the CuPc nano column with special morphology was integrated as in-situ sensor device which exhibits high sensitivity and selectivity towards Cl2 at room temperature with a minimum detection limit as low as 0.08 ppm. The response of sensor was found to increase linearly (26∼659% with the increase for Cl2 within concentration range (0.08∼4.0ppm. These results clearly demonstrate the great potential of the nano column growth and device integration approach for sensor device.

  7. Removal of dichloromethane from waste gas streams using a hybrid bubble column/biofilter bioreactor.

    Science.gov (United States)

    Abtahi, Mehrnoosh; Naddafi, Kazem; Mesdaghinia, Alireza; Yaghmaeian, Kamyar; Nabizadeh, Ramin; Jaafarzadeh, Nematollah; Rastkari, Noushin; Nazmara, Shahrokh; Saeedi, Reza

    2014-01-09

    The performance of a hybrid bubble column/biofilter (HBCB) bioreactor for the removal of dichloromethane (DCM) from waste gas streams was studied in continuous mode for several months. The HBCB bioreactor consisted of two compartments: bubble column bioreactor removing DCM from liquid phase and biofilter removing DCM from gas phase. Effect of inlet DCM concentration on the elimination capacity was examined in the DCM concentration range of 34-359 ppm with loading rates ranged from 2.2 to 22.8 g/m3.h and constant total empty bed retention time (EBRT) of 200 s. In the equal loading rates, the elimination capacity and removal efficiency of the biofilter were higher than the corresponding values of the bubble column bioreactor. The maximum elimination capacity of the HBCB bioreactor was determined to be 15.7 g/m3.h occurred in the highest loading rate of 22.8 g/m3.h with removal efficiency of 69%. The overall mineralization portion of the HBCB bioreactor was in the range of 72-79%. The mixed liquor acidic pH especially below 5.5 inhibited microbial activity and decreased the elimination capacity. Inhibitory effect of high ionic strength was initiated in the mixed liquor electrical conductivity of 12.2 mS/cm. This study indicated that the HBCB bioreactor could benefit from advantages of both bubble column and biofilter reactors and could remove DCM from waste gas streams in a better manner.

  8. Determination of thermodynamic properties of poly(cyclohexyl methacrylate)by inverse gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Ismet KAYA; Cigdem Yigit PALA

    2014-01-01

    In this work,some thermodynamic properties of poly( cyclohexyl methacrylate)were studied by inverse gas chromatography( IGC). For this purpose,the polymeric substance was coated on Chromosorb W and which was filled into a glass column. The retention times(tr)of the probes were determined from the interactions of poly(cyclohexyl methacrylate)with n-pentane,n-hexane,n-heptane,n-octane,n-decane, methanol,ethanol,2-propanol,butanol,acetone,ethyl methyl ketone,benzene,toluene and o-xylene by IGC technique. Then,the specific volume(V0g)was determined for each probe molecule. By using(1/T;lnV0g) graphics,the glass transition temperature of poly( cyclohexyl methacrylate)was found to be 373 K. The adsorp-tion heat under the glass transition temperature(ΔH a ),and partial molar heat of sorption above the glass tran-sition(ΔHS1 ),partial molar free energy of sorption(ΔGS1 )and partial molar entropy of sorption(ΔSS1 )belong-ing to sorption for every probe were calculated. The partial molar heat of mixing at infinite dilution(ΔH∞1 ), partial molar free energy of mixing at infinite dilution(ΔG∞1 ),Flory-Huggins interaction parameter(χ∞12 )and weight fraction activity coefficient(a1/w1)∞ values of polymer-solute systems were calculated at different col-umn temperatures. The solubility parameters(δ2 )of the polymer were obtained by IGC technique.

  9. A Semianalytical Ocean Color Inversion Algorithm with Explicit Water Column Depth and Substrate Reflectance Parameterization

    Science.gov (United States)

    Mckinna, Lachlan I. W.; Werdell, P. Jeremy; Fearns, Peter R. C.; Weeks, Scarla J.; Reichstetter, Martina; Franz, Bryan A.; Shea, Donald M.; Feldman, Gene C.

    2015-01-01

    A semianalytical ocean color inversion algorithm was developed for improving retrievals of inherent optical properties (IOPs) in optically shallow waters. In clear, geometrically shallow waters, light reflected off the seafloor can contribute to the water-leaving radiance signal. This can have a confounding effect on ocean color algorithms developed for optically deep waters, leading to an overestimation of IOPs. The algorithm described here, the Shallow Water Inversion Model (SWIM), uses pre-existing knowledge of bathymetry and benthic substrate brightness to account for optically shallow effects. SWIM was incorporated into the NASA Ocean Biology Processing Group's L2GEN code and tested in waters of the Great Barrier Reef, Australia, using the Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua time series (2002-2013). SWIM-derived values of the total non-water absorption coefficient at 443 nm, at(443), the particulate backscattering coefficient at 443 nm, bbp(443), and the diffuse attenuation coefficient at 488 nm, Kd(488), were compared with values derived using the Generalized Inherent Optical Properties algorithm (GIOP) and the Quasi-Analytical Algorithm (QAA). The results indicated that in clear, optically shallow waters SWIM-derived values of at(443), bbp(443), and Kd(443) were realistically lower than values derived using GIOP and QAA, in agreement with radiative transfer modeling. This signified that the benthic reflectance correction was performing as expected. However, in more optically complex waters, SWIM had difficulty converging to a solution, a likely consequence of internal IOP parameterizations. Whilst a comprehensive study of the SWIM algorithm's behavior was conducted, further work is needed to validate the algorithm using in situ data.

  10. Investigation of surface properties of physico-chemically modified natural fibres using inverse gas chromatography

    CSIR Research Space (South Africa)

    Cordeiro, N

    2011-01-01

    Full Text Available Inverse gas chromatography (IGC) is a suitable method to determine surface energy of natural fibres when compared to wetting techniques. In the present study, the surface properties of raw and modified lignocellulosic fibres have been investigated...

  11. Application of finite inverse gas chromatography in hypromellose acetate succinate-water-acetone systems.

    Science.gov (United States)

    Chiu, Sheng-Wei; Sturm, Derek R; Moser, Justin D; Danner, Ronald P

    2016-09-30

    A modification of a GC was developed to investigate both infinitely dilute and finite concentrations of solvents in polymers. Thermodynamic properties of hypromellose acetate succinate (HPMCAS-L)-acetone-water systems are important for the optimization of spray-drying processes used in pharmaceutical manufacturing of solid dispersion formulations. These properties, at temperatures below the glass transition temperature, were investigated using capillary column inverse gas chromatography (CCIGC). Water was much less soluble in the HPMCAS-L than acetone. Experiments were also conducted at infinitely dilute concentrations of one of the solvents in HPMCAS-L that was already saturated with the other solvent. Overall the partitioning of the water was not significantly affected by the presence of either water or acetone in the polymer. The acetone partition coefficient decreased as either acetone or water was added to the HPMCAS-L. A representation of the HPMCAS-L structure in terms of UNIFAC groups has been developed. With these groups, the UNIFAC-vdw-FV model did a reasonable job of predicting the phase equilibria in the binary and ternary systems. The Flory-Huggins correlation with fitted interaction parameters represented the data well.

  12. Estimation of mechanical dispersion and dispersivity in a soil-gas system by column experiments and the dusty gas model.

    Science.gov (United States)

    Hibi, Yoshihiko; Kanou, Yuki; Ohira, Yuki

    2012-04-01

    In a previous study, column experiments were carried out with Toyoura sand (permeability 2.05×10(-11)m(2)) and Toyoura sand mixed with bentonite (permeability 9.96×10(-13)m(2)) to obtain the molecular diffusion coefficient, the Knudsen diffusion coefficient, the tortuosity for the molecular diffusion coefficient, and the mechanical dispersion coefficient of soil-gas systems. In this study, we conducted column experiments with field soil (permeability 2.0×10(-13)m(2)) and showed that the above parameters can be obtained for both less-permeable and more-permeable soils by using the proposed method for obtaining the parameters and performing column experiments. We then estimated dispersivity from the mechanical dispersion coefficients obtained by the column experiments. We found that the dispersivity depended on the mole fraction of the tracer gas and could be represented by a quadratic equation. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. A micro gas chromatography column with a micro thermal conductivity detector for volatile organic compound analysis.

    Science.gov (United States)

    Sun, J H; Cui, D F; Chen, X; Zhang, L L; Cai, H Y; Li, H

    2013-02-01

    In this paper, a micro gas chromatography (μGC) system contained a μGC column and a micro thermal conductivity detector (μTCD) was proposed. In order to reduce the volume of the system, some micro heaters were integrated on the surface and backside of the GC column, which could provide a robust temperature programming capability and rapidly increase the temperature of the μGC column. In addition, a silicon-glass μTCD with four-thermistor thermal conductivity cells that can offer significant advantages over previously reported designs including low dead volume, good thermal isolation, and elimination of the thermal noise was proposed in this paper. Experimental results have indicated that the μGC system with a detection limit of several ppm concentration levels separated and detected the benzene, toluene, and styrene in less than 3 min, and the μGC system also exhibited a good linear response in the test range.

  14. Gas chromatography on wall-coated open-tubular columns with ionic liquid stationary phases.

    Science.gov (United States)

    Poole, Colin F; Lenca, Nicole

    2014-08-29

    Ionic liquids have moved from novel to practical stationary phases for gas chromatography with an increasing portfolio of applications. Ionic liquids complement conventional stationary phases because of a combination of thermophysical and solvation properties that only exist for ionic solvents. Their high thermal stability and low vapor pressure makes them suitable as polar stationary phases for separations requiring high temperatures. Ionic liquids are good solvents and can be used to expand the chemical space for separations. They are the only stationary phases with significant hydrogen-bond acidity in common use; they extend the hydrogen-bond basicity of conventional stationary phases; they are as dipolar/polarizable as the most polar conventional stationary phases; and some ionic liquids are significantly less cohesive than conventional polar stationary phases. Problems in column coating techniques and related low column performance, column activity, and stationary phase reactivity require further exploration as the reasons for these features are poorly understood at present.

  15. The opposing effects of bacterial activity and gas production on anaerobic TCE degradation in soil columns.

    Science.gov (United States)

    Singhal, Naresh; Jaffé, Peter; Maier, Walter; Jho, Eun Hea

    2007-11-01

    This laboratory study explores the effect of growth substrate concentration on the anaerobic degradation of trichloroethylene (TCE) in sand packed columns. In all columns the growth substrate rapidly degraded to gas, that formed a separate phase. Biomass accumulated in the 0-4.8 cm section of the columns in proportion to the influent growth substrate concentration and biomass concentrations in the remaining sections of all columns were similar to the column receiving the lowest substrate concentration. Increases in growth substrate concentration up to 3030 mg-CODl(-1) promoted TCE degradation, but a further increase to 14300 mg-CODl(-1) reduced the amount of TCE completely dechlorinated but did not affect the production of chlorinated TCE intermediates. The mathematical model developed here satisfactorily described the enhancement in TCE dehalogenation for substrate concentration up to 3030 mg-CODl(-1); reproducing TCE dehalogenation for 14300 mg-CODl(-1) required that the moisture content used in simulation be lowered to 0.1. The study shows that volatilization of TCE can be significant and volatilization losses should be taken into account when anaerobic activity in in-situ bioremediation applications is stimulated via addition of growth substrates. An implication of the modeling simulations is that maintaining a lower, but uniform, substrate concentration over the contaminated region may lead to faster contaminant degradation.

  16. On-column micro gas chromatography detection with capillary-based optical ring resonators.

    Science.gov (United States)

    Shopova, Siyka I; White, Ian M; Sun, Yuze; Zhu, Hongying; Fan, Xudong; Frye-Mason, Greg; Thompson, Aaron; Ja, Shiou-jyh

    2008-03-15

    We developed a novel on-column micro gas chromatography (microGC) detector using capillary based optical ring resonators (CBORRs). The CBORR is a thin-walled fused silica capillary with an inner diameter ranging from a few tens to a few hundreds of micrometers. The interior surface of the CBORR is coated with a layer of stationary phase for gas separation. The circular cross section of the CBORR forms a ring resonator and supports whispering gallery modes (WGMs) that circulate along the ring resonator circumference hundreds of times. The evanescent field extends into the core and is sensitive to the refractive index change induced by the interaction between the gas sample and the stationary phase. The WGM can be excited and monitored at any location along the CBORR by placing a tapered optical fiber against the CBORR, thus enabling on-column real-time detection. Rapid separation of both polar and nonpolar samples was demonstrated with subsecond detection speed. Theoretical work was also established to explain the CBORR detection mechanism. While low-nanogram detection limits are observed in these preliminary tests, many methods for improvements are under investigation. The CBORR is directly compatible with traditional capillary GC columns without any dead volumes. Therefore, the CBORR-based muGC is a very promising technology platform for rapid, sensitive, and portable analytical devices.

  17. Study of the gas content in two-phase downflow in a sieve-plate column

    Energy Technology Data Exchange (ETDEWEB)

    Utkin, V.A.; Chekhov, O.S.; Stepanov, A.M.

    1986-04-10

    This paper presents a thorough study of the gas content in two-phase downflow in a column sectioned by sieve plates. The air-water system was used in the experiments and the mass flow rates of the gas and liquid in the column were varied in the ranges of 0.5-10 and 200-900 kg m/sup -2/.sec/sup -1/, respectively. The gas content of the stream was determined by gamma radioscopy. A scintilalation counter was used as the gamma-radiation detector. Determination of the gas content over the height of the apparatus showed that the flow structure is formed immediately after the first plate and then remains constant. The influence of the viscosity of the liquid on the gas content of the stream was studied with the use of plates of 40.5% open cross section. Statistical analysis of the experimental data revealed the existence of two patterns of two-phase flow in the apparatus.

  18. The influence of polymeric membrane gas spargers on hydrodynamics and mass transfer in bubble column bioreactors

    DEFF Research Database (Denmark)

    Tirunehe, Gossay; Norddahl, B.

    2016-01-01

    Gas sparging performances of a flat sheet and tubular polymeric membranes were investigated in 3.1 m bubble column bioreactor operated in a semi batch mode. Air–water and air–CMC (Carboxymethyl cellulose) solutions of 0.5, 0.75 and 1.0 % w/w were used as interacting gas–liquid mediums. CMC...... solutions were employed in the study to simulate rheological properties of bioreactor broth. Gas holdup, bubble size distribution, interfacial area and gas–liquid mass transfer were studied in the homogeneous bubbly flow hydrodynamic regime with superficial gas velocity (UG) range of 0.0004–0.0025 m....../s. The study indicated that the tubular membrane sparger produced the highest gas holdup and densely populated fine bubbles with narrow size distribution. An increase in liquid viscosity promoted a shift in bubble size distribution to large stable bubbles and smaller specific interfacial area. The tubular...

  19. Reliability of gas holdup measurements using the differential pressure method in a cyclone-static micro-bubble flotation column

    Institute of Scientific and Technical Information of China (English)

    Xia Wencheng; Yang Jianguo; Wang Yuling

    2011-01-01

    Gas holdup iS one of the Key parameters in flotation process.Gas holclup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method.The errors were used to establish optimum measurement positions.The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius).The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column.The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column.The average gas holdup measurement can be replaced bv regional gas holdup values.

  20. Study on the Holdup and Mass Transfer Performances for Gas-Liquid-Liquid System in a Screen Plate Column

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The gas and dispersed phase holdups and mass transfer coefficients of liquid-iquid were determined for gas-liquid-liquid three phase system in a screen plate column. The flow pattern of gas-liquid-liquid three phase system was studied under different gas velocities. The shape factors showed the geometric properties of screen plates and the corrected drop characteristic velocities were introduced. The phase holdup in two phases was correlated. The research results indicated that mass transfer coefficient for liquid-liquid system in a column with screen plates and gas agitation was found to increase apparently.

  1. Rapid tandem-column micro-gas chromatography based on optofluidic ring resonators with multi-point on-column detection.

    Science.gov (United States)

    Sun, Yuze; Liu, Jing; Howard, Daniel J; Frye-Mason, Greg; Thompson, Aaron K; Ja, Shiou-jyh; Fan, Xudong

    2010-01-01

    We demonstrated a novel tandem-column micro-gas chromatography (microGC) based on optofluidic ring resonator (OFRR). The OFRR is a thin-walled fused silica capillary whose interior surface is coated with a polymeric stationary phase. The circular cross section of the OFRR forms the micro-ring resonator and supports whispering gallery modes (WGMs). Via tapered optical fibers in contact with the OFRR, the WGM can be excited externally at any positions along the OFRR capillary, thus enabling multi-point, on-column, real-time detection of vapor molecules flowing through the OFRR. In the present OFRR-based tandem-column-based microGC implementation, a 180 cm long conventional GC column coated with a nonpolar stationary phase was followed by a relatively short OFRR column coated with a polar phase. Two detection positions, one at the inlet of the OFRR and the other a few centimeters downstream, were used to monitor the separation achieved by the first and the second column, respectively. Owing to the multi-point on-column detection that provides complementary retention time information on each chemical compound, co-eluted analytes can be well separated and identified on at least one detection channel and no modulation is needed at the interface of tandem columns. Separation and detection of twelve analytes with various volatilities and polarities within four minutes were demonstrated. In addition, the chromatograms obtained from three different locations along the OFRR column demonstrated the system's capability of on-column monitoring of the separation process for the target analyte in a vapor mixture. Our results will lead to the development of a rapid, simple, and portable microGC system with significantly improved selectivity and chemical identification capabilities.

  2. Polar Factorization and Generalized Inverse for Row (Column) Skew Symmetric Matrix%行(列)反对称矩阵的极分解及其广义逆

    Institute of Scientific and Technical Information of China (English)

    袁晖坪

    2013-01-01

    The author studied the polar factorization and generalized inverse of row (column) skew symmetric matrix, which leads to some new results. In addition, the formula of the polar factorization and generalized inverse of row (column) skew symmetric matrix were given, which makes calculation easier, and some perturbation bounds of polar factorization of row (column) skew symmetric matrix were also presented.%考虑行(列)反对称矩阵的极分解和广义逆,给出了行(列)反对称矩阵的极分解和广义逆计算公式,并对行(列)反对称矩阵的极分解作了扰动分析.结果表明,所给方法既减少了计算量与存储量,又保证了数值精度.

  3. 行(列)对称矩阵的极分解与广义逆%Polar Factorization and Generalized Inverse for Row (Column)Symmetric Matrix

    Institute of Scientific and Technical Information of China (English)

    袁晖坪

    2015-01-01

    考虑行(列)对称矩阵的极分解与广义逆,给出了行(列)对称矩阵的极分解和广义逆的计算公式,并导出了行(列)对称矩阵极分解的系列扰动界。结果表明,所给方法既减少了计算量与存储量,又不会降低数值精度。%The author studied the polar factorization and generalized inverse of row (column ) symmetric matrix.In addition,the formulae of the polar factorization and generalized inverse of row (column) symmetric matrix were given,which make calculation easier.And some perturbation bounds of the polar factorization of row (column)symmetric matrix were also presented.

  4. Column Density Maps of the I-GALFA HI Survey: Evidence for Dark Gas?

    Science.gov (United States)

    Gibson, Steven J.; Koo, B.; Douglas, K. A.; Newton, J. H.; Peek, J. E.; Hughes, J. M.; Spraggs, M.; Park, G.; Kang, J.; Heiles, C. E.; Korpela, E. J.

    2014-01-01

    The gas in galactic disks, including our own, occurs in a wide range of temperatures and densities, most of which are unsuitable for star formation. Somehow, diffuse atomic clouds are collected into colder, denser molecular clouds that can collapse under their own gravity. The molecular condensation process is not directly observable, and the gas itself is often ``dark'' to standard probes like optically thin HI 21cm emission or the CO 2.6mm line. However, the presence of this dark gas can often be inferred from infrared dust emission in excess of what is expected for the observed HI and CO content. We have mapped apparent HI column densities in the Inner-Galaxy Arecibo L-band Feed Array (I-GALFA) survey, which covers a 1600 square degree region at 4-arcminute resolution in the first Galactic quadrant. We compare these ``naive'' HI columns to others derived from Planck first-release CO and dust maps and NE2001 model dispersion measures to identify a number of areas with potentially significant dark gas. We discuss whether optically thick HI or CO-free H2 is more likely to dominate the dark column, and we consider the effects of possible biases on our results. We acknowledge support from the National Science Foundation, the NASA Kentucky Space Grant Consortium, Western Kentucky University, and the Gatton Academy. I-GALFA (www.naic.edu igalfa) is a GALFA-HI survey observed with the 7-beam ALFA receiver on the 305-meter William E. Gordon Telescope. The Arecibo Observatory is a U.S. National Science Foundation facility operated under sequential cooperative agreements with Cornell University and SRI International, the latter in alliance with the Ana G. Mendez-Universidad Metropolitana and the Universities Space Research Association.

  5. Performance of a Novel Gas Separation Research Column at Sanford Laboratory

    Science.gov (United States)

    Alanson Chiller, Angela; Chiller, Christopher; Mei, Dongming

    2014-03-01

    A world-wide rise in demand for ultrapure materials has necessitated innovation in the production of low impurity and isotopically separated materials that either has not been utilized in these new applications or relies on aging or energy intensive methods. These materials are sought after for large physics investigations, nuclear non-proliferation detection industries, medical imaging and new frontiers in electronic applications. Techniques in separating and purifying nuclear magnetic resonance isotopes of carbon, oxygen, xenon, krypton, and nitrogen are being developed at Sanford Laboratory, Lead, SD. A two-meter laboratory scale selective phase change column designed specifically for real-time sampling of the gas space at specific temperature and pressure is operated at gas/liquid and gas/solid equilibrium temperatures and pressures for selected gases. We report initial results and future applications. Research Funded by SD Governors 2010 Center.

  6. Relating pressure tuned coupled column ensembles with the solvation parameter model for tunable selectivity in gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Chin, Sung-Tong; Marriott, Philip J

    2016-07-15

    The differential pressure drop of carrier gas by tuning the junction point pressure of a coupled column gas chromatographic system leads to a unique selectivity of the overall separation, which can be tested using a mixture of compounds with a wide range of polarity. This study demonstrates a pressure tuning (PT) GC system employing a microfluidic Deans switch located at the mid-point of the two capillary columns. This PT system allowed variations of inlet-outlet pressure differences of the two columns in a range of 52-17psi for the upstream column and 31-11psi for the downstream column. Peak shifting (differential migration) of compounds due to PT difference are related to a first order regression equation in a Plackett-Burman factorial study. Increased first (upstream) column pressure drop makes the second column characteristics more significant in the coupled column retention behavior, and conversely increased second (downstream) column pressure drop makes the first column characteristics more apparent; such variation can result in component swapping between polar and non-polar compounds. The coupled column system selectivity was evaluated in terms of linear solvation energy relationship (LSER) parameters, and their relation with different pressure drop effects has been constructed by applying multivariate principle component analysis (PCA). It has been found that the coupled column PT system descriptors provide a result that shows a clear clustering of different pressure settings, somewhat intermediate between those of the two commercial columns. This is equivalent to that obtained from a conventional single-column GC analysis where the interaction energy contributed from the stationary phases can be significantly adjusted by choice of midpoint PT. This result provides a foundation for pressure differentiation for selectivity enhancement.

  7. The Carina Nebula and Gum 31 molecular complex: I. Molecular gas distribution, column densities and dust temperatures

    CERN Document Server

    Rebolledo, David; Green, Anne; Braiding, Catherine; Molinari, Sergio; Wong, Graeme; Blackwell, Rebecca; Elia, Davide; Schisano, Eugenio

    2015-01-01

    We report high resolution observations of the $^{12}$CO$(1\\rightarrow0)$ and $^{13}$CO$(1\\rightarrow0)$ molecular lines in the Carina Nebula and the Gum 31 region obtained with the 22-m Mopra telescope as part of the The Mopra Southern Galactic Plane CO Survey. We cover 8 deg$^2$ from $l = 285^{\\circ}$ to 290$^{\\circ}$, and from $b = -1.5^{\\circ}$ to +0.5$^{\\circ}$. The molecular gas column density distributions from both tracers have a similar range of values. By fitting a grey-body function to the observed infrared spectral energy distribution from Herschel maps, we derive gas column densities and dust temperatures. The gas column density has values in the range from $6.3\\times\\ 10^{20}$ to $1.4\\times 10^{23}$ cm$^{-2}$, while the dust temperature has values in the range from 17 to 43 K. The gas column density derived from the dust emission is approximately described by a log-normal function for a limited range of column densities. A high-column density tail is clearly evident for the gas column density dis...

  8. A Gas Chromatographic Analysis of Light Hydrocarbons on a Column Packed with Modified Silica Gel

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A one-meter long column packed with silica gel is used to separate light hydrocarbons. The silica gel has been modified with several kinds of gas chromatography stationary phases. Among these, PEG 2000 shows fairly good effect when using 80-100 meshes silica gel for the separation of mixture of methane, ethane, ethylene, acetylene, propane, propylene and n-, i-butane. The different behavior of silica gel between batch to batch is also found. When silica gel is coated with a small amount of Al2O3 prepared with sol-gel method, better resolution has been observed on a 2-meter column compared with the non-modified silica gel.

  9. The influence of polymeric membrane gas spargers on hydrodynamics and mass transfer in bubble column bioreactors.

    Science.gov (United States)

    Tirunehe, Gossaye; Norddahl, B

    2016-04-01

    Gas sparging performances of a flat sheet and tubular polymeric membranes were investigated in 3.1 m bubble column bioreactor operated in a semi batch mode. Air-water and air-CMC (Carboxymethyl cellulose) solutions of 0.5, 0.75 and 1.0 % w/w were used as interacting gas-liquid mediums. CMC solutions were employed in the study to simulate rheological properties of bioreactor broth. Gas holdup, bubble size distribution, interfacial area and gas-liquid mass transfer were studied in the homogeneous bubbly flow hydrodynamic regime with superficial gas velocity (U(G)) range of 0.0004-0.0025 m/s. The study indicated that the tubular membrane sparger produced the highest gas holdup and densely populated fine bubbles with narrow size distribution. An increase in liquid viscosity promoted a shift in bubble size distribution to large stable bubbles and smaller specific interfacial area. The tubular membrane sparger achieved greater interfacial area and an enhanced overall mass transfer coefficient (K(L)a) by a factor of 1.2-1.9 compared to the flat sheet membrane.

  10. Modeling gas formation and mineral precipitation in a granular iron column.

    Science.gov (United States)

    Jeen, Sung-Wook; Amos, Richard T; Blowes, David W

    2012-06-19

    In granular iron permeable reactive barriers (PRBs), hydrogen gas formation, entrapment and release of gas bubbles, and secondary mineral precipitation have been known to affect the permeability and reactivity. The multicomponent reactive transport model MIN3P was enhanced to couple gas formation and release, secondary mineral precipitation, and the effects of these processes on hydraulic properties and iron reactivity. The enhanced model was applied to a granular iron column, which was studied for the treatment of trichloroethene (TCE) in the presence of dissolved CaCO(3). The simulation reasonably reproduced trends in gas formation, secondary mineral precipitation, permeability changes, and reactivity changes observed over time. The simulation showed that the accumulation of secondary minerals reduced the reactivity of the granular iron over time, which in turn decreased the rate of mineral accumulation, and also resulted in a gradual decrease in gas formation over time. This study provides a quantitative assessment of the evolving nature of geochemistry and permeability, resulting from coupled processes of gas formation and mineral precipitation, which leads to a better understanding of the processes controlling the granular iron reactivity, and represents an improved method for incorporating these factors into the design of granular iron PRBs.

  11. Acoustic 2D full waveform inversion to solve gas cloud challenges

    Directory of Open Access Journals (Sweden)

    Srichand Prajapati

    2015-09-01

    Full Text Available The existing conventional inversion algorithm does not provide satisfactory results due to the complexity of propagated wavefield though the gas cloud. Acoustic full waveform inversion has been developed and applied to a realistic synthetic offshore shallow gas cloud feature with Student-t approach, with and without simultaneous sources encoding. As a modeling operator, we implemented the grid based finite-difference method in frequency domain using second order elastic wave equation. Jacobin operator and its adjoint provide a necessary platform for solving full waveform inversion problem in a reduced Hessian matrix. We invert gas cloud model in 5 frequency band selected from 1 to 12 Hz, each band contains 3 frequencies. The inversion results are highly sensitive to the misfit. The model allows better convergence and recovery of amplitude losses. This approach gives better resolution then the existing least-squares approach. In this paper, we implement the full waveform inversion for low frequency model with minimum number of iteration providing a better resolution of inversion results.

  12. High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column

    Science.gov (United States)

    Zhu, Xiaofeng; Sun, Jianhai; Ning, Zhanwu; Zhang, Yanni; Liu, Jinhua

    2016-04-01

    Monitoring Volatile organic compounds (VOCs) was a very important measure for preventing environmental pollution, therefore, a mini gas chromatography (GC) flame ionization detector (FID) system integrated with a mini H2 generator and a micro GC column was developed for environmental VOC monitoring. In addition, the mini H2 generator was able to make the system explode from far away due to the abandoned use of a high pressure H2 source. The experimental result indicates that the fabricated mini GC FID system demonstrated high repeatability and very good linear response, and was able to rapidly monitor complicated environmental VOC samples.

  13. Effects of Gravity on Cocurrent Two-Phase Gas-Liquid Flows Through Packed Columns

    Science.gov (United States)

    Motil, Brian J.; Balakotaiah, Vemuri; Kamotani, Yasuhiro

    2001-01-01

    This work presents the experimental results of research on the influence of gravity on flow pattern transitions, pressure drop and flow characteristics for cocurrent gas-liquid two-phase flow through packed columns. The flow pattern transition data indicates that the pulse flow regime exists over a wider range of gas and liquid flow rates under reduced gravity conditions compared to normal gravity cocurrent down-flow. This is illustrated by comparing the flow regime transitions found in reduced gravity with the transitions predicted by Talmor. Next, the effect of gravity on the total pressure drop in a packed column is shown to depend on the flow regime. The difference is roughly equivalent to the liquid static head for bubbly flow but begins to decrease at the onset of pulse flow. As the spray flow regime is approached by increasing the gas to liquid ratio, the effect of gravity on pressure drop becomes negligible. Finally, gravity tends to suppress the amplitude of each pressure pulse. An example of this phenomenon is presented.

  14. Identification of collapse columns using acoustic impedance inversion%声波阻抗反演识别陷落柱研究

    Institute of Scientific and Technical Information of China (English)

    管永伟; 陈同俊; 崔若飞; 赵立明; 彭刘亚

    2016-01-01

    岩溶陷落柱是煤田开采中一种常见的地质灾害体.为研究利用反演方法识别陷落柱,根据煤矿陷落柱的地质特征,设计了整体塌落型和垮落型两类陷落柱地质模型,并通过正演模拟获得了相应的地震剖面.通过对正演剖面进行声波阻抗反演,发现整体塌落型陷落柱的波阻抗值明显高于煤层,垮落型陷落柱柱体与煤层接触的部位的波阻抗值略高于煤层,并且柱内地层存在沉降现象.将这一结论应用到实际三维地震采区,发现与实际资料的吻合度较好,陷落柱的位置和规模在反演上有较清晰的显示,能够识别直径小于50 m的小型陷落柱异常.%Karst collapse column is a common geologic hazards in coal mining,in order to research and identify the collapse column by seismic inversion methods,according to the geology features of collapse column,overall collapsing collapse column model which has the integrity of the formation and caving collapse column model which is filled with gravel are designed.Seismic forward modeling of collapse column model with different macroaxis of two types and the inversion of the forward results are studied.The results show that the overall collapsing collapse column has higher impedance than coal seam,the caving collapse column has higher impedance when contact with the coal seam and its inner formation displays subsidence.The conclusions above are applied to study on 3D seismic data of a real mining district and the results are highly consistent with actual data.The location and scale of collapse column are displayed clearly on inversion results.Moreover,the small collapse column whose macroaxis are less than 50m are identified.

  15. Determinations of gas-liquid partition coefficients using capillary chromatographic columns. Alkanols in squalane.

    Science.gov (United States)

    Tascon, Marcos; Romero, Lílian M; Acquaviva, Agustín; Keunchkarian, Sonia; Castells, Cecilia

    2013-06-14

    This study focused on an investigation into the experimental quantities inherent in the determination of partition coefficients from gas-liquid chromatographic measurements through the use of capillary columns. We prepared several squalane - (2,6,10,15,19,23-hexamethyltetracosane) - containing columns with very precisely known phase ratios and determined solute retention and hold-up times at 30, 40, 50 and 60°C. We calculated infinite dilution partition coefficients from the slopes of the linear regression of retention factors as a function of the reciprocal of the phase ratio by means of fundamental chromatographic equations. In order to minimize gas-solid and liquid-solid interface contributions to retention, the surface of the capillary inner wall was pretreated to guarantee a uniform coat of stationary phase. The validity of the proposed approach was first tested by estimating the partition coefficients of n-alkanes between n-pentane and n-nonane, for which compounds data from the literature were available. Then partition coefficients of sixteen aliphatic alcohols in squalane were determined at those four temperatures. We deliberately chose these highly challenging systems: alcohols in the reference paraffinic stationary phase. These solutes exhibited adsorption in the gas-liquid interface that contributed to retention. The corresponding adsorption constant values were estimated. We fully discuss here the uncertainties associated with each experimental measurement and how these fundamental determinations can be performed precisely by circumventing the main drawbacks. The proposed strategy is reliable and much simpler than the classical chromatographic method employing packed columns.

  16. Simple, specific analysis of organophosphorus and carbamate pesticides in sediments using column extraction and gas chromatography

    Science.gov (United States)

    Belisle, A.A.; Swineford, D.M.

    1988-01-01

    A simple, specific procedure was developed for the analysis of organophosphorus and carbamate pesticides in sediment. The wet soil was mixed with anhydrous sodium sulfate to bind water and the residues were column extracted in acetone:methylene chloride (1:l,v/v). Coextracted water was removed by additional sodium sulfate packed below the sample mixture. The eluate was concentrated and analyzed directly by capillary gas chromatography using phosphorus and nitrogen specific detectors. Recoveries averaged 93 % for sediments extracted shortly after spiking, but decreased significantly as the samples aged.

  17. Separation of alkanes and aromatic compounds by packed column gas chromatography using functionalized multi-walled carbon nanotubes as stationary phases.

    Science.gov (United States)

    Speltini, Andrea; Merli, Daniele; Quartarone, Eliana; Profumo, Antonella

    2010-04-23

    In the present work, we show a novel application of pristine and functionalized Multi-Walled Carbon Nanotubes (MWCNTs) as stationary phase in low-cost packed columns for the gas chromatographic separation of alkanes and aromatic hydrocarbons. The MWCNTs were deeply investigated by means of physical and chemical methods, like thermal analysis, IR and atomic force microscopy, and Inverse Gas Chromatography (IGC) in order to correlate the adsorption process and surface properties with the material purity level and functionalization degree. The derivatization process of the pristine nanotubes was a key factor to achieve a successful separation of both the light n-alkanes (C3-C5) and the related isomers (C4-C5 branched alkanes). Satisfactory results were similarly obtained in the case of separation of aromatic hydrocarbons (BTX).

  18. Macroporous polymer monoliths as second dimension columns in comprehensive two-dimensional gas chromatography: a feasibility study

    NARCIS (Netherlands)

    D. Peroni; R.J. Vonk; W. van Egmond; H.-G. Janssen

    2012-01-01

    When the typical column combinations are used, comprehensive two-dimensional gas chromatography (GC × GC) suffers from the impossibility to operate both dimensions at their optimum carrier gas velocities at the same time. This as a result of the flow mismatch caused by the different dimensions of th

  19. Gas-Liquid Mass Transfer in a Slurry Bubble Column Reactor under High Temperature andHigh Pressure

    Institute of Scientific and Technical Information of China (English)

    杨卫国; 王金福; 金涌

    2001-01-01

    The gas-liquid mass transfer of H2 and CO in a high temperature and high-pressure three-phase slurry bubble column reactor is studied. The gas-liquid volumetric mass transfer coefficients kLa are obtained by measuring the dissolution rate of H2 and CO. The influences of the main operation conditions, such as temperature, pressure,superficial gas velocity and solid concentration, are studied systematically. Two empirical correlations are proposed to predict kLa values for H2 and CO in liquid paraffln/solid particles slurry bubble column reactors.

  20. Surface Energy Characteristics of Toner Particles by Automated Inverse Gas Chromatography

    NARCIS (Netherlands)

    Segeren, L.H.G.J.; Wouters, M.E.L.; Bos, M.; van den Berg, J.W.A.; Vancso, Gyula J.

    2002-01-01

    Inverse gas chromatography (IGC) was applied to the surface energy study of surfaces of toner particles. The dispersive component of the surface energy was determined for three toner materials by infinite dilution IGC. The values obtained were comparable to the values obtained from contact angle

  1. Wind driven vertical transport in a vegetated, wetland water column with air-water gas exchange

    Science.gov (United States)

    Poindexter, C.; Variano, E. A.

    2010-12-01

    gas transfer coefficient, k, for both a vegetated condition and a control condition (no cylinders). The presence of cylinders in the tank substantially increased the rate of the gas transfer. For the highest wind speed, the gas transfer coefficient was several times higher when cylinders were present compared to when they were not. The gas transfer coefficient for the vegetated condition also proved sensitive to wind speed, increasing markedly with increasing mean wind speeds. Profiles of dissolved oxygen revealed well-mixed conditions in the bulk water column following prolonged air-flow above the water surface, suggesting application of the thin-film model is appropriate. The enhanced gas exchange observed might be explained by increased turbulent kinetic energy within the water column and the anisotropy of the cylinder array, which constrains horizontal motions more than vertical motions. Improved understanding of gas exchange in vegetated water columns may be of particularly use to investigations of carbon fluxes and soil accretion in wetlands. Reference: Nepf, H. (1999), Drag, turbulence, and diffusion in flow through emergent vegetation, Water Resour. Res., 35(2), 479-489.

  2. Total Column Greenhouse Gas Monitoring in Central Munich: Automation and Measurements

    Science.gov (United States)

    Chen, Jia; Heinle, Ludwig; Paetzold, Johannes C.; Le, Long

    2016-04-01

    It is challenging to use in-situ surface measurements of CO2 and CH4 to derive emission fluxes in urban regions. Surface concentrations typically have high variance due to the influence of nearby sources, and they are strongly modulated by mesoscale transport phenomena that are difficult to simulate in atmospheric models. The integrated amount of a tracer through the whole atmosphere is a direct measure of the mass loading of the atmosphere given by emissions. Column measurements are insensitive to vertical redistribution of tracer mass, e.g. due to growth of the planetary boundary layer, and are also less influenced by nearby point sources, whose emissions are concentrated in a thin layer near the surface. Column observations are more compatible with the scale of atmospheric models and hence provide stronger constraints for inverse modeling. In Munich we are aiming at establishing a regional sensor network with differential column measurements, i.e. total column measurements of CO2 and CH4 inside and outside of the city. The inner-city station is equipped with a compact solar-tracking Fourier transform spectrometer (Bruker EM27/SUN) in the campus of Technische Universität München, and our measurements started in Aug. 2015. The measurements over seasons will be shown, as well as preliminary emission studies using these observations. To deploy the compact spectrometers for stationary monitoring of the urban emissions, an automatic protection and control system is mandatory and a challenging task. It will allow solar measurements whenever the sun is out and reliable protection of the instrument when it starts to rain. We have developed a simplified and highly reliable concept for the enclosure, aiming for a fully automated data collection station without the need of local human interactions. Furthermore, we are validating and combining the OCO-2 satellite-based measurements with our ground-based measurements. For this purpose, we have developed a software tool that

  3. Partition coefficients of organic compounds in new imidazolium based ionic liquids using inverse gas chromatography.

    Science.gov (United States)

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noël

    2009-06-05

    Partition coefficients of organic compounds in four ionic liquids: 1-ethanol-3-methylimidazolium tetrafluoroborate, 1-ethanol-3-methylimidazolium hexafluorophosphate, 1,3-dimethylimidazolium dimethylphosphate and 1-ethyl-3-methylimidazolium diethylphosphate were measured using inverse gas chromatography from 303.3 to 332.55K. The influence of gas-liquid and gas-solid interfacial adsorption of different solutes on ionic liquids was also studied. Most of the polar solutes were retained largely by partition while light hydrocarbons were retained predominantly by interfacial adsorption on the ionic liquids studied in this work. The solvation characteristics of the ionic liquids were evaluated using the Abraham solvation parameter model.

  4. Determination of selenium and tellurium in the gas phase using specific columns and atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Muangnoicharoen, S.; Chiou, K.Y.; Manuel, O.K.

    1986-11-01

    Total selenium and tellurium in the gas phase were analyzed after adsorption on gold-coated beads and charcoal. The thermally eluting gas was trapped on columns filled with quartz beads that were cooled in an ice bath. The beads were boiled in dilute HCl, and the resulting solution was analyzed for Se and Te by graphite furnace atomic absorption spectrometry. Their results demonstrate that gold-coated beads efficiently trap gaseous Se and Te at a low gas flow rate, but at higher flow rates charcoal traps are more expedient. With charcoal traps, it was found that local air samples contain Se in the range of 0.92-3.05 ng m/sup -3/ and Te in the range of 0.10-0.34 ng m/sup -3/. Detection limits down to about 0.1 ng m/sup -3/ allow the ready detection of Se and Te in rural air with a precision of about +/- 6% at the nanogram level of Te and about +/- 4% at the nanogram level of Se.

  5. [Determination of ethylene glycol in workplace air by capillary column gas chromatography].

    Science.gov (United States)

    Li, Tiandi; Lin, Yiran; Zhang, Wen; He, Juntao

    2015-12-01

    To establish the method of capillary column gas chromatography for determination of ethylene glycol in workplace air. Ethylene glycol in workplace air was collected with silicone tube, desorbed with methanol, separated with FFAP (nitroterephthalic acid-modified polyethylene glycol)capillary column, and measured with flame ionization detector. The detection limit of ethylene glycol was 0.41 mg/L, the lower limit of quantification was 1.4 mg/L, the range of measurement was 1.4~163.9 mg/L, and the minimum detectable concentration was 0.3 mg/m3 (1.5 L of air was collected as the sample). This method had a good repeatability, the relative standard deviation was 1.4%~5.2%, the average desorption efficiency was 94.4%~101.7%, and the sampling efficiency was 99.2%~100%. The penetrating capacity of 200 mg silicone was higher than 6.9 mg, and the samples could be preserved for 14 days at room temperature. The method has a low detection limit, high accuracy, and good precision, which is feasible for determination of ethylene glycol in workplace air.

  6. Balloon-Borne Full-Column Greenhouse Gas Profiling Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Marc L [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-03-01

    The vertical distributions of CO2, CH4, and other gases provide important constraints for the determination of terrestrial and ocean sources and sinks of carbon and other biogeochemical processes in the Earth system. The DOE Biological and Environmental Research Program (DOE-BER) and the NOAA Earth System Research Laboratory (NOAA-ESRL) collaborate to quantify the vertically resolved distribution of atmospheric carbon-cycle gases (CO2, and CH4) within approximately 99% of the atmospheric column at the DOE ARM Southern Great Plains Facility in Oklahoma. In 2015, flights were delayed while research at NOAA focused on evaluating sources of systematic errors in the gas collection and analysis system and modifying the sampling system to provide duplicate air samples in a single flight package. In 2017, we look forward to proposing additional sampling and analysis at ARM-SGP (and other sites) that characterize the vertical distribution of CO2 and CH4 over time and space.

  7. Comparison of the effect of grounding the column wall in gas-solid fluidized beds on electrostatic charge generation

    Energy Technology Data Exchange (ETDEWEB)

    Sowinski, Andrew; Mayne, Antonio; Javed, Bassam; Mehrani, Poupak, E-mail: poupak.mehrani@uottawa.ca [University of Ottawa, Chemical and Biological Engineering Department, 161 Louis Pasteur St., Ottawa, Ontario, K1N 6N5 (Canada)

    2011-06-23

    In gas-solid fluidized beds as particles are fluidized, they continuously come into contact with other particles, as well as the fluidization column wall. This generates electrostatic charges by means of triboelectrification and frictional charging, leading to particle agglomeration, reactor wall fouling, and eventually process downtime and large financial losses. Grounding the fluidization column has been considered as a means of helping electrostatic charge dissipation within fluidized beds; however, in industrial applications despite the process vessels being grounded, the electrostatic problem still persists. This work focused on the effect of fluidization column grounding on particle wall fouling. Experiments were conducted in an atmospheric system consist of a 0.1 m in diameter carbon steel fluidization column. The mass and charge-to-mass ratio (q/m) of the particles that remained adhered to the column wall upon the completion of one hour fluidization period were measured in an electrically isolated and grounded columns to quantitatively determine the amount of reactor wall fouling. Polyethylene particles with different particle size ranges (300- 1000 {mu}m) were fluidized with extra dry air at 1.5 times their respective minimum fluidization velocity (u{sub mf}). Results obtained in the grounded fluidization column were not significantly different from those in the isolated column for all particle size ranges tested where the particles mass collected and q/m and were found to be generally similar.

  8. Nitrogen transformations and greenhouse gas emissions from a riparian wetland soil: An undisturbed soil column study

    Energy Technology Data Exchange (ETDEWEB)

    Munoz-Leoz, Borja [Department of Chemical and Environmental Engineering, University of the Basque Country, UPV/EHU, E-48013 Bilbao (Spain); Antigueedad, Inaki [Department of Geodynamic, University of the Basque Country, UPV/EHU, E-48940 Leioa (Spain); Garbisu, Carlos [Department of Ecosystems, NEIKER-Tecnalia, E-48160 Derio (Spain); Ruiz-Romera, Estilita, E-mail: estilita.ruiz@ehu.es [Department of Chemical and Environmental Engineering, University of the Basque Country, UPV/EHU, E-48013 Bilbao (Spain)

    2011-01-15

    Riparian wetlands bordering intensively managed agricultural fields can act as biological filters that retain and transform agrochemicals such as nitrate and pesticides. Nitrate removal in wetlands has usually been attributed to denitrification processes which in turn imply the production of greenhouse gases (CO{sub 2} and N{sub 2}O). Denitrification processes were studied in the Salburua wetland (northern Spain) by using undisturbed soil columns which were subsequently divided into three sections corresponding to A-, Bg- and B2g-soil horizons. Soil horizons were subjected to leaching with a 200 mg NO{sub 3}{sup -} L{sup -1} solution (rate: 90 mL day{sup -1}) for 125 days at two different temperatures (10 and 20 {sup o}C), using a new experimental design for leaching assays which enabled not only to evaluate leachate composition but also to measure gas emissions during the leaching process. Column leachate samples were analyzed for NO{sub 3}{sup -} concentration, NH{sub 4}{sup +} concentration, and dissolved organic carbon. Emissions of greenhouse gases (CO{sub 2} and N{sub 2}O) were determined in the undisturbed soil columns. The A horizon at 20 {sup o}C showed the highest rates of NO{sub 3}{sup -} removal (1.56 mg N-NO{sub 3}{sup -} kg{sup -1} DW soil day{sup -1}) and CO{sub 2} and N{sub 2}O production (5.89 mg CO{sub 2} kg{sup -1} DW soil day{sup -1} and 55.71 {mu}g N-N{sub 2}O kg{sup -1} DW soil day{sup -1}). For the Salburua wetland riparian soil, we estimated a potential nitrate removal capacity of 1012 kg N-NO{sub 3}{sup -} ha{sup -1} year{sup -1}, and potential greenhouse gas emissions of 5620 kg CO{sub 2} ha{sup -1} year{sup -1} and 240 kg N-N{sub 2}O ha{sup -1} year{sup -1}. - Research Highlights: {yields}A new experimental design is proposed for leaching assays to simulate nitrogen transformations in riparian wetland soil. {yields}Denitrification is the main process responsible for nitrate removal in the riparian zone of Salburua wetland. {yields

  9. Gas Holdups of Small and Large Bubbles in a Large-scale Bubble Column with Elevated Pressure

    Institute of Scientific and Technical Information of China (English)

    JIN Hai-bo; YANG Suo-he; ZHANG Tong-wang; TONG Ze-min

    2004-01-01

    Gas holdups of large bubbles and small bubbles were measured by means of dynamic gas disengagement approach in the pressured bubble column with a diameter of 0. 3 m and a height of 6. 6 m. The effects of superficial gas velocity, liquid surface tension, liquid viscosity andsystem pressure on gas holdups of small bubbles and large bubbles were investigated. The holdup of large bubbles increases and the holdup of small bubbles decreases with an increase of liquid viscosity. Meanwhile, the holdup of large bubbles decreases with increasing the system pressure. A correlation for the holdup of small bubbles was obtained from the experimental data.

  10. Evaluation of a subsurface oxygenation technique using colloidal gas aphron injections into packed column reactors

    Energy Technology Data Exchange (ETDEWEB)

    Wills, R.A.; Coles, P.

    1991-11-01

    Bioremediation may be a remedial technology capable of decontaminating subsurface environments. The objective of this research was to evaluate the use of colloidal gas aphron (CGA) injection, which is the injection of micrometer-size air bubbles in an aqueous surfactant solution, as a subsurface oxygenation technique to create optimal growth conditions for aerobic bacteria. Along with this, the capability of CGAs to act as a soil-washing agent and free organic components from a coal tar-contaminated matrix was examined. Injection of CGAs may be useful for remediation of underground coal gasification (UCG) sites. Because of this, bacteria and solid material from a UCG site located in northeastern Wyoming were used in this research. Colloidal gas aphrons were generated and pumped through packed column reactors (PCRS) containing post-burn core materials. For comparison, PCRs containing sand were also studied. Bacteria from this site were tested for their capability to degrade phenol, a major contaminant at the UCG site, and were also used to bioaugment the PCR systems. In this study we examined: (1) the effect of CGA injection on dissolved oxygen concentrations in the PCR effluents, (2) the effect of CGA, H[sub 2]O[sub 2], and phenol injections on bacterial populations, (3) the stability and transport of CGAs over distance, and (4) CGA injection versus H[sub 2]O[sub 2] injection as an oxygenation technique.

  11. Evaluation of a subsurface oxygenation technique using colloidal gas aphron injections into packed column reactors

    Energy Technology Data Exchange (ETDEWEB)

    Wills, R.A.; Coles, P.

    1991-11-01

    Bioremediation may be a remedial technology capable of decontaminating subsurface environments. The objective of this research was to evaluate the use of colloidal gas aphron (CGA) injection, which is the injection of micrometer-size air bubbles in an aqueous surfactant solution, as a subsurface oxygenation technique to create optimal growth conditions for aerobic bacteria. Along with this, the capability of CGAs to act as a soil-washing agent and free organic components from a coal tar-contaminated matrix was examined. Injection of CGAs may be useful for remediation of underground coal gasification (UCG) sites. Because of this, bacteria and solid material from a UCG site located in northeastern Wyoming were used in this research. Colloidal gas aphrons were generated and pumped through packed column reactors (PCRS) containing post-burn core materials. For comparison, PCRs containing sand were also studied. Bacteria from this site were tested for their capability to degrade phenol, a major contaminant at the UCG site, and were also used to bioaugment the PCR systems. In this study we examined: (1) the effect of CGA injection on dissolved oxygen concentrations in the PCR effluents, (2) the effect of CGA, H{sub 2}O{sub 2}, and phenol injections on bacterial populations, (3) the stability and transport of CGAs over distance, and (4) CGA injection versus H{sub 2}O{sub 2} injection as an oxygenation technique.

  12. Measurement of Infinite Diluted Activity Coefficient of Solvents in Polymer by Inverse Gas Chromatography Method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@1 INTRODUCTION Due to its short experimental time, little sample needed, suitable for broad temperature range, inverse gas chromatography (IGC) has been widely used to measure variety of properties of polymer systems, such as the intinite diluted activity coefficients of solvent in polymer, the glass transition temperature of polymer and the surface properties of polymer[1-5], etc. Those data have been used to develop the group contribution method for the prediction of thermodynamic proper-ties of polymer solution[6].

  13. Surface energy of bovine dentin and enamel by means of inverse gas chromatography.

    Science.gov (United States)

    Okulus, Zuzanna; Strzemiecka, Beata; Czarnecka, Beata; Buchwald, Tomasz; Voelkel, Adam

    2015-04-01

    Adhesion between tooth tissues and dental fillings depends on the surface energy of both connected materials. Bond strength can be determined directly or indirectly as a work of adhesion on the basis of values of surface energy of these materials. Inverse gas chromatography (IGC) is one of the methods of surface energy examination. In this study the values of total surface energy components of wet and dry teeth fragments (enamel, crown dentin and root dentin) were determined with the use of inverse gas chromatography. Inverse gas chromatography has never been used for investigation of surface energy of natural tooth tissues. Different storage conditions were examined - wet and dry. Different values of surface energy are observed according to the type of tooth tissue (dentin or enamel), occurring place (crown or root) and storage conditions (dry or wet). The effect of tissue type and occurring place was the greatest, while storage conditions were of secondary importance. Surface energy depends on composition of tissue, its surface area and the presence of pores. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. From slant column densities to trace gas profiles: Post processing data from the new MAX-DOAS network in Mexico City

    Science.gov (United States)

    Friedrich, M. M.; Stremme, W.; Rivera, C. I.; Arellano, E. J.; Grutter, M.

    2014-12-01

    The new MAX-DOAS network in Mexico City provides results of O4, HCHO and NO2 slant column densities (SCD). Here, we present a new numerical code developed to retrieve gas profiles of NO2 and HCHO using radiative transfer simulations. We present first results of such profiles from the MAX-DOAS station located at UNAM campus. The code works in two steps: First, the O4 slant column density information is used to retrieve an aerosol profile. As an a-priori aerosol profile, we use averaged ceilometer data measured at UNAM and scaled to the total optical depth provided by the Aeronet data base. In the second step, the retrieved aerosol profile information is used together with the trace gas (HCHO or NO2) SCDs to retrieve the trace gas profiles. The inversion is based on a gauss-newton iteration scheme and uses constrained least square fitting with either optimal estimation or Tihkonov regularization. For the latter, the regulation matrix is currently constructed from the discrete first derivative operator. The forward model uses the radiative transfer code VLIDORT. The inputs to VLIDORT are calculated using temperature and pressure information from daily radiosounde measurements and aerosol single scattering optical depths and asymmetry factors from the Aeronet data base for Mexico City. For the gas absorption cross sections we use the same values as were used for the SCD calculation from the recorded spectra using QDOAS. Besides demonstrating the functionality of the algorithm showing profile retrievals of simulated SCDs with added random noise, we present HCHO and NO2 profiles retrieved from SCDs calculated from the MAX-DOAS measurements at UNAM campus at selected days.

  15. 3D joint inversion using seismic data and marine controlled-source electromagnetic data for evaluating gas hydrate concentrations

    Science.gov (United States)

    Kim, B.; Byun, J.; Seol, S. J.; Jeong, S.; Chung, Y.; Kwon, T.

    2015-12-01

    For many decades, gas hydrates have been received great attention as a potential source of natural gas. Therefore, the detailed information of structures of buried gas hydrates and their concentrations are prerequisite for the production for the gas hydrate as a reliable source of alternate energy. Recently, for this reason, a lot of gas hydrate assessment methods have been proposed by many researchers. However, it is still necessary to establish as new method for the further improvement of the accuracy of the 3D gas hydrate distribution. In this study, we present a 3D joint inversion method that provides superior quantitative information of gas hydrate distributions using 3D seismic data obtained by ocean-bottom cable (OBC) and marine controlled-source electromagnetic (CSEM) data. To verify our inversion method, we first built the general 3D gas hydrate model containing vertical methane-flow pathways. With the described model, we generated synthetic 3D OBC data and marine CSEM data using finite element modeling algorithms, respectively. In the joint inversion process, to obtain the high-resolution volumetric P-wave velocity structure, we applied the 3D full waveform inversion algorithm to the acquired OBC data. After that, the obtained P-wave velocity model is used as the structure constraint to compute cross-gradients with the updated resistivity model in the EM inversion process. Finally, petrophysical relations were applied to estimate volumetric gas hydrate concentrations. The proposed joint inversion process makes possible to obtain more precise quantitative gas hydrate assessment than inversion processes using only seismic or EM data. This technique can be helpful for accurate decision-making in gas hydrate development as well as in their production monitoring.

  16. Development of micromachined preconcentrators and gas chromatographic separation columns by an electroless gold plating technology

    Science.gov (United States)

    Kuo, C.-Y.; Chen, P.-S.; Chen, H.-T.; Lu, C.-J.; Tian, W.-C.

    2017-03-01

    In this study, a simple process for fabricating a novel micromachined preconcentrator (μPCT) and a gas chromatographic separation column (μSC) for use in a micro gas chromatograph (μGC) using one photomask is described. By electroless gold plating, a high-surface-area gold layer was deposited on the surface of channels inside the μPCT and μSC. For this process, (3-aminopropyl) trimethoxysilane (APTMS) was used as a promoter for attaching gold nanoparticles on a silicon substrate to create a seed layer. For this purpose, a gold sodium sulfite solution was used as reagent for depositing gold to form heating structures. The microchannels of the μPCT and μSC were coated with the adsorbent and stationary phase, Tenax-TA and polydimethylsiloxane (DB-1), respectively. μPCTs were heated at temperatures greater than 280 °C under an applied electrical power of 24 W and a heating rate of 75 °C s‑1. Repeatable thermal heating responses for μPCTs were achieved; good linearity (R 2  >  0.9997) was attained at three heating rates for the temperature programme for the μSC (0.2, 0.5 and 1 °C s‑1). The volatile organic compounds (VOCs) toluene and m-xylene were concentrated over the μPCT by rapid thermal desorption (peak width of half height (PWHH)  7900. The VOCs acetone, benzene, toluene, m-xylene and 1,3,5-trimethylbenzene were also separated on the μSC as evidenced by their different retention times (47–184 s).

  17. Atmospheric inverse modeling with known physical bounds: an example from trace gas emissions

    Directory of Open Access Journals (Sweden)

    S. M. Miller

    2013-09-01

    Full Text Available Many inverse problems in the atmospheric sciences involve parameters with known physical constraints. Examples include non-negativity (e.g., emissions of some urban air pollutants or upward limits implied by reaction or solubility constants. However, probabilistic inverse modeling approaches based on Gaussian assumptions cannot incorporate such bounds and thus often produce unrealistic results. The atmospheric literature lacks consensus on the best means to overcome this problem, and existing atmospheric studies rely on a limited number of the possible methods with little examination of the relative merits of each. This paper investigates the applicability of several approaches to bounded inverse problems and is also the first application of Markov chain Monte Carlo (MCMC to estimation of atmospheric trace gas fluxes. The approaches discussed here are broadly applicable. A common method of data transformations is found to unrealistically skew estimates for the examined example application. The method of Lagrange multipliers and two MCMC methods yield more realistic and accurate results. In general, the examined MCMC approaches produce the most realistic result but can require substantial computational time. Lagrange multipliers offer an appealing alternative for large, computationally intensive problems when exact uncertainty bounds are less central to the analysis. A synthetic data inversion of US anthropogenic methane emissions illustrates the strengths and weaknesses of each approach.

  18. Rise characteristics of gas bubbles in a 2D rectangular column: VOF simulations vs experiments

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, R.; Baten, J.M. van

    1999-10-01

    About five centuries ago, Leonardo da Vinci described the sinuous motion of gas bubbles rising in water. The authors have attempted to simulate the rise trajectories of bubbles of 4, 5, 7, 8, 9, 12, and 20 mm in diameter rising in a 2D rectangular column filled with water. The simulations were carried out using the volume-of-fluid (VOF) technique developed by Hirt and Nichols (J. Computational Physics, 39, 201--225 (1981)). To solve the Navier-Stokes equations of motion the authors used a commercial solver, CFX 4.1c of AEA Technology, UK. They developed their own bubble-tracking algorithm to capture sinuous bubble motions. The 4 and 5 mm bubbles show large lateral motions observed by Da Vinci. The 7, 8 and 9 mm bubble behave like jellyfish. The 12 mm bubble flaps its wings like a bird. The extent of lateral motion of the bubbles decreases with increasing bubble size. Bubbles larger than 20 mm in size assume a spherical cap form and simulations of the rise characteristics match experiments exactly. VOF simulations are powerful tools for a priori determination of the morphology and rise characteristics of bubbles rising in a liquid. Bubble-bubble interactions are also properly modeled by the VOF technique.

  19. Inverse Gas Chromatography with Film Cell Unit: An Attractive Alternative Method to Characterize Surface Properties of Thin Films.

    Science.gov (United States)

    Klein, Géraldine L; Pierre, Guillaume; Bellon-Fontaine, Marie-Noëlle; Graber, Marianne

    2015-09-01

    Inverse gas chromatography (IGC) is widely used for the characterization of surfaces. The present work describes a novel IGC tool, the recently developed film cell module, which measures monolithic thin solid film surface properties, whereas only samples in powder or fiber state or polymer-coated supports can be studied by classic IGC. The surface energy of four different solid supports was measured using both classic IGC with columns packed with samples in the powder state, and IGC with the new film cell module or the sessile drop technique, using samples in the film state. The total surface energy and its dispersive and specific components were measured for glass, polyethylene, polyamide and polytetrafluoroethylene. Similar results were obtained for the four materials using the three different techniques. The main conclusion is that the new film cell module for IGC is an attractive alternative to the sessile drop technique as it gives very accurate and reproducible results for surface energy components, with significant savings in time and the possible control of sample humidity and temperature. This film cell module for IGC extends the application field of IGC to any thin solid film and can be used to study the effect of any surface treatment on surface energy.

  20. Closed-Flow Column Experiments - A Numerical Study on Breakthrough Oscillations Reveals a Decreased Uncertainty in the Inverse Determination of Transport Parameters

    Science.gov (United States)

    Ritschel, Thomas; Totsche, Kai Uwe

    2016-04-01

    The identification of transport parameters by inverse modeling often suffers from large uncertainties due to equifinality or parameter correlation when models are fitted to observations of the solute breakthrough in column outflow experiments. This issue can be approached by increasing the information potential of the observation, e.g. by running multiple experiments at different boundary conditions. A promising complementary approach of designing soil column experiments in order to further increase the obtained information is the closed-flow mode that is characterized by the recirculation of the effluent solution into the solution supply vessel. Depending on the experimental conditions, the solute concentration in the mixing vessel and the effluent follows a damped sinusoidal oscillation. As a result, the closed-flow experiment provides additional observables in the breakthrough curve, which are the initial exponential decrease in concentration in mixing vessel concentration, the oscillation wavelength and the extent of damping, each indicative for corresponding transport parameters. Furthermore, the concentration in the porous medium and the mixing vessel converges to equilibrium due to the closed loop. The evaluation of these emergent features allows intrinsic control over boundary conditions and impacts the uncertainty of parameters in inverse modeling. We present a comprehensive numerical sensitivity analysis to illustrate the potential application of closed-flow experiments. We can show that the sensitivity with respect to the apparent dispersion can be controlled by the experimenter leading to a decrease in parameter uncertainty as compared to classical experiments by an order of magnitude for optimal settings. With these finding we are also able to show a reduction of equifinality found for situations, where rate-limited interactions impede a proper determination of the apparent dispersion and rate coefficients. This renders the closed-flow mode a useful

  1. MAMAP - a new spectrometer system for column-averaged methane and carbon dioxide observations from aircraft: retrieval algorithm and first inversions for point source emission rates

    Science.gov (United States)

    Krings, T.; Gerilowski, K.; Buchwitz, M.; Reuter, M.; Tretner, A.; Erzinger, J.; Heinze, D.; Burrows, J. P.; Bovensmann, H.

    2011-04-01

    MAMAP is an airborne passive remote sensing instrument designed for measuring columns of methane (CH4) and carbon dioxide (CO2). The MAMAP instrument consists of two optical grating spectrometers: One in the short wave infrared band (SWIR) at 1590-1690 nm to measure CO2 and CH4 absorptions and another one in the near infrared (NIR) at 757-768 nm to measure O2 absorptions for reference purposes. MAMAP can be operated in both nadir and zenith geometry during the flight. Mounted on an airplane MAMAP can effectively survey areas on regional to local scales with a ground pixel resolution of about 29 m × 33 m for a typical aircraft altitude of 1250 m and a velocity of 200 km h-1. The retrieval precision of the measured column relative to background is typically ≲ 1% (1σ). MAMAP can be used to close the gap between satellite data exhibiting global coverage but with a rather coarse resolution on the one hand and highly accurate in situ measurements with sparse coverage on the other hand. In July 2007 test flights were performed over two coal-fired powerplants operated by Vattenfall Europe Generation AG: Jänschwalde (27.4 Mt CO2 yr-1) and Schwarze Pumpe (11.9 Mt CO2 yr-1), about 100 km southeast of Berlin, Germany. By using two different inversion approaches, one based on an optimal estimation scheme to fit Gaussian plume models from multiple sources to the data, and another using a simple Gaussian integral method, the emission rates can be determined and compared with emissions as stated by Vattenfall Europe. An extensive error analysis for the retrieval's dry column results (XCO2 and XCH4) and for the two inversion methods has been performed. Both methods - the Gaussian plume model fit and the Gaussian integral method - are capable of delivering reliable estimates for strong point source emission rates, given appropriate flight patterns and detailed knowledge of wind conditions.

  2. 列分块矩阵的Moore-Penrose逆%The Moore-Penrose Inverse of Column Partitioned Matrix

    Institute of Scientific and Technical Information of China (English)

    邱红兵; 罗季

    2012-01-01

    利用矩阵分块,给出了求一般矩阵Moore-Penrose逆的一种新方法,且新方法只需利用矩阵的初等变换即可实现.%A new method of solving the Moor-Penrose inverse of a matrix with partitioned matrix is given, and the method can be realized only with the elementary transformation of matrix.

  3. Determination of Surface Energy of Natural Zeolite by Inverse Gas Chromatography

    Science.gov (United States)

    Bilgiç, Ceyda; Karakehya, Naile

    2016-10-01

    In this study, surface energy of natural zeolite was investigated using inverse gas chromatography (IGC). Purified zeolite was prepared from natural zeolite applying decantation and centrifugation process together. For IGC studies, retention time of n-octane, n-nonane and n-decane were measured at infinite dilution conditions, between 250 and 280 °C. Dispersive component of the surface energy (γd S)of purified zeolite was calculated. γd S values calculated using Schultz et al methods decrease with temperature.

  4. Acid-base and surface energy characterization of grafted polyethylene using inverse gas chromatography.

    Science.gov (United States)

    Uhlmann, Petra; Schneider, Steffen

    2002-09-06

    For a specific design of interfaces, i.e. in composites and blends, it is essential to know the surface thermodynamics of the components. Polyethylene grafted with maleic anhydride and maleic anhydride-styrene mixtures, respectively, was the component of interest of our investigations. Inverse gas chromatography (IGC) at infinite dilution was shown to be an appropriate method to evaluate the dispersive and acid-base surface characteristics although there is an influence of bulk absorption and morphology when performing IGC above the glass transition temperature of the polymer.

  5. Inverse gas chromatography determination of some physicochemical parameters of a high rank Colombian coal

    Energy Technology Data Exchange (ETDEWEB)

    Baquero-Haeberlin, M.C.; Rincon, J.M. [Universidad Nacional de Colombia, Santafe de Bogota (Colombia). Departamento de Quimica

    1997-12-31

    Dispersive component of the free surface energy of a Colombian semianthracite type coal - Paramo de Guerrero - was determined by Inverse Gas Chromatography (IGC), at zero coverage injecting the series of n-alkanes at 313, 333, 353 and 373 K. For the retention time, the mass center determination was used instead of the maximum peak in the chromatograms. The free surface energy (-{Delta}G{sub A}) increase linearly with the carbon atom number to the alkanes but is not constant due, probably to the conformational structure of the probes. The IGC study of the adsorption process in function of the temperature, provides the respective Enthalpy and Entropy values. (orig.)

  6. Use of inverse gas chromatography to characterize cotton fabrics and their interactions with fragrance molecules at controlled relative humidity.

    Science.gov (United States)

    Cantergiani, Ennio; Benczédi, Daniel

    2002-09-06

    The present work focused on the surface characterization and fragrance interactions of a common cotton towel at different relative humidities (RHs) using inverse gas chromatography (IGC) and dynamic vapour sorption. The sigmoidal water sorption isotherms showed a maximum of 16% (w/w) water uptake with limited swelling at 100% RH. This means that water interacts strongly with cotton and might change its initial physico-chemical properties. The same cotton towel was then packed in a glass column and characterized by IGC at different relative humidities, calculating the dispersive and specific surface energy components. The dispersive component of the surface energy decreases slightly as a function of relative humidity (42 mJ/m2 at 0% RH to 36 mJ/m2 at 80% RH) which would be expected from swelling of the humidified cotton. The Gutmann's donor constant Kd increased from 0.28 kJ/mol at 0% RH to 0.42 kJ/mol at 80% RH, indicating that a greater hydrophilic surface exists at 80% RH, which is also as expected. Water, undecane and four fragrance molecules (dimetol, benzyl acetate, decanal and phenylethanol) were used to investigate cotton-fragrance interactions between 0 and 80% RH. The adsorption enthalpies and the Henry's constants were calculated and are discussed. The higher values for the adsorption enthalpies of polar molecules such as dimetol and phenylethanol suggest the presence of hydrogen bonds as the main adsorption mechanism. The Henry's constant of dimetol was also determined by headspace gas chromatography measurements at 20% RH, giving a similar value (230 nmol/Pa g by IGC and 130 nmol/Pa g by headspace GC), supporting the usefulness of IGC for such determinations. This work confirms the usefulness of chromatographic methods to investigate biopolymers such as textiles, starches and hairs.

  7. Studies on Chromatographic Properties of Perhydroxycucurbit[6]uril as a New Type of Gas Chromatographic Column Packing Material

    Institute of Scientific and Technical Information of China (English)

    LI Lai-Sheng; WANG Shang-Wen; CHEN Xiong-Quan; LIU Chao; XU Li-Li

    2008-01-01

    Perhydroxycucurbit[6]uril{(HO)12CB[6]}has been used successfully as a stationary phase for packed column gas chromatography for the first time.Perhydroxycucurbit[6]uril stationary phase(PSP)exhibited wide operational temperature,outstanding thermostability and good selectivities to various organic compounds,such as alkanes,aromatic hydrocarbons,alcohols,esters,ketones,amines,etc.It was also found that some positional isomers,such as disubstituted benzenes could be well separated on this column.PSP has excellent separation abilities to some complicate samples,for example,commercial toilet water.Some mechanism of the new packing for GC-separation was preliminarily discussed.It was observed that the partial inclusion complexation of PSP with analytes could improve separation selectivity and column efficiency,instead of complete inclusion.Moreover,PSP exhibited low baseline shift even at dramatically programmed temperature for complicate samples covering a wide boiling point range so as to fast assay.

  8. Ionic liquids as novel stationary phases in gas liquid chromatography: inverse or normal isotope effect?

    Science.gov (United States)

    Schmarr, Hans-Georg; Slabizki, Petra; Müntnich, Sabrina; Metzger, Carmen; Gracia-Moreno, Elisa

    2012-12-28

    The separation of deuterated and non-deuterated compounds in gas liquid partitioning chromatography (GLC) on silicone type stationary phase usually results in the inverse isotope effect. With ionic liquids (ILs) as stationary phase, however, this may show a totally different nature. The inverse isotope effect, in which heavier (deuterated) isotopic compounds (isotopologues) elute earlier, is to be expected when van der Waals (London) dispersion forces play a dominant role in the solute-stationary phase interaction. Such (apolar) interactions seem to play only a minor role when ILs are the stationary phases, leading to only a marginal inverse isotope effect, e.g. for the separation of 2,4,6-trichloroanisole and its [(2)H(5)]-isotopologue on 1,12-di(tripropylphosphonium) dodecane bis(trifluoromethansulfonyl) amide (commercialized as SLB-IL59, Supelco). Indeed, with the most polar stationary phase available (commercialized as SLB-IL111; Supelco), this separation showed a normal isotope effect. Further examples are presented and the nature of the isotope effect observed is discussed.

  9. Comparison of two gas-liquid chromatograph columns for the analysis of fatty acids in ruminant meat.

    Science.gov (United States)

    Alves, Susana P; Bessa, Rui J B

    2009-06-26

    Two gas-liquid chromatograph capillary columns for the analysis of fatty acids (FA) in ruminant fat are compared. Those columns are the CP-Sil 88 of 100 m long with a highly polar stationary phase and the Omegawax 250 of 30 m long with a stationary phase of intermediate polarity. Fatty acid methyl ester (FAME) patterns of branched-chain, cis and trans octadecenoate isomers, as well as conjugated and non-conjugated 18:2 and 18:3 isomers are fairly different between columns, even though most of the FAME could be separated on either column. However, the CP-Sil 88 showed better resolution of 18:1 isomers than Omegawax 250. The analysis of 96 samples of ruminant meat fat in both chromatographic systems showed that averages obtained for total FA content and for most of the individual FA did not differ between columns. Moreover, regression analysis of Omegawax and CP-Sil 88 data is highly correlated. Quantitative differences between chromatographic systems were detected for samples containing more than 66 mg fatty acids per gram of muscle dry matter.

  10. Execute Elementary Row and Column Operations on the Partitioned Matrix to Compute M-P Inverse A†

    Directory of Open Access Journals (Sweden)

    Xingping Sheng

    2014-01-01

    Full Text Available We first study the complexity of the algorithm presented in Guo and Huang (2010. After that, a new explicit formula for computational of the Moore-Penrose inverse A† of a singular or rectangular matrix A. This new approach is based on a modified Gauss-Jordan elimination process. The complexity of the new method is analyzed and presented and is found to be less computationally demanding than the one presented in Guo and Huang (2010. In the end, an illustrative example is demonstrated to explain the corresponding improvements of the algorithm.

  11. Investigation of Pinus mugo essential oil oxygenated fraction by combined use of gas chromatography and dry column chromatography.

    Science.gov (United States)

    A, M B; Coran, S A; Giannellini, V; Vincieri, F F; Moneti, G

    1981-09-01

    The oxygenated compounds of Pinus mugo Turra essential oil were investigated by a combination of GC and dry column chromatography (DCC) coordinated by GC data processing. The collected data resulted in a bar graph ("normalized" gas chromatogram) giving the RRT's and relative amounts of 68 components; 38 of them were identified by MS and IR. The described procedure may be used for essential oil analysis in general.

  12. Alignment of retention time obtained from multicapillary column gas chromatography used for VOC analysis with ion mobility spectrometry.

    Science.gov (United States)

    Perl, Thorsten; Bödeker, Bertram; Jünger, Melanie; Nolte, Jürgen; Vautz, Wolfgang

    2010-07-01

    Multicapillary column (MCC) ion mobility spectrometers (IMS) are increasingly in demand for medical diagnosis, biological applications and process control. In a MCC-IMS, volatile compounds are differentiated by specific retention time and ion mobility when rapid preseparation techniques are applied, e.g. for the analysis of complex and humid samples. Therefore, high accuracy in the determination of both parameters is required for reliable identification of the signals. The retention time in the MCC is the subject of the present investigation because, for such columns, small deviations in temperature and flow velocity may cause significant changes in retention time. Therefore, a universal correction procedure would be a helpful tool to increase the accuracy of the data obtained from a gas-chromatographic preseparation. Although the effect of the carrier gas flow velocity and temperature on retention time is not linear, it could be demonstrated that a linear alignment can compensate for the changes in retention time due to common minor deviations of both the carrier gas flow velocity and the column temperature around the MCC-IMS standard operation conditions. Therefore, an effective linear alignment procedure for the correction of those deviations has been developed from the analyses of defined gas mixtures under various experimental conditions. This procedure was then applied to data sets generated from real breath analyses obtained in clinical studies using different instruments at different measuring sites for validation. The variation in the retention time of known signals, especially for compounds with higher retention times, was significantly improved. The alignment of the retention time--an indispensable procedure to achieve a more precise identification of analytes--using the proposed method reduces the random error caused by small accidental deviations in column temperature and flow velocity significantly.

  13. An inverse method for flue gas shielded metal surface temperature measurement based on infrared radiation

    Science.gov (United States)

    Zhang, B.; Xu, C. L.; Wang, S. M.

    2016-07-01

    The infrared temperature measurement technique has been applied in various fields, such as thermal efficiency analysis, environmental monitoring, industrial facility inspections, and remote temperature sensing. In the problem of infrared measurement of the metal surface temperature of superheater surfaces, the outer wall of the metal pipe is covered by radiative participating flue gas. This means that the traditional infrared measurement technique will lead to intolerable measurement errors due to the absorption and scattering of the flue gas. In this paper, an infrared measurement method for a metal surface in flue gas is investigated theoretically and experimentally. The spectral emissivity of the metal surface, and the spectral absorption and scattering coefficients of the radiative participating flue gas are retrieved simultaneously using an inverse method called quantum particle swarm optimization. Meanwhile, the detected radiation energy simulated using a forward simulation method (named the source multi-flux method) is set as the input of the retrieval. Then, the temperature of the metal surface detected by an infrared CCD camera is modified using the source multi-flux method in combination with these retrieved physical properties. Finally, an infrared measurement system for metal surface temperature is built to assess the proposed method. Experimental results show that the modified temperature is closer to the true value than that of the direct measured temperature.

  14. 广义行(列)对称矩阵的Moore-Penrose逆%The Moore-Penrose Inverse for Generalized Row(Column)Symmetric Matrix

    Institute of Scientific and Technical Information of China (English)

    郭伟

    2012-01-01

    The concept of generalized row(column)symmetric matrix is given,its full rank decomposition and singular value decomposition are studied.By the two decompositions and orthogonal equivalence,three shortcut counting methods of the Moore-Penrose inverse for generalized row(column)symmetric matrix are obtained,which can dramatically reduce the amount of calculation and save the CPU time and memory,which extend the results of the related references and which spread its application scope.%提出了广义行(列)对称矩阵概念,研究了它的满秩分解和奇异值分解,利用这两种分解以及正交相抵,得到3种广义行列对称矩阵Moore-Penrose逆的快速算法,可极大节省其计算量和存储量;推广了相关文献的结果,使其应用范围更广.

  15. A New Method for the Measurement of Gas Holdup in Solid-Suspended Bubble Columns

    OpenAIRE

    "宮原, 敏郎; ミヤハラ, トシロウ"; Toshiro, "Miyahara

    1996-01-01

    A method for the measurement for gas holdup in gas-liquid-solid multiphase devices is developed. The method depends on measurements of hydrostatic pressuress in the three-phase dispersion followed by interruption of gas flow and solids and liquid holdups without gas flow.

  16. MAMAP – a new spectrometer system for column-averaged methane and carbon dioxide observations from aircraft: retrieval algorithm and first inversions for point source emission rates

    Directory of Open Access Journals (Sweden)

    H. Bovensmann

    2011-09-01

    Full Text Available MAMAP is an airborne passive remote sensing instrument designed to measure the dry columns of methane (CH4 and carbon dioxide (CO2. The MAMAP instrument comprises two optical grating spectrometers: the first observing in the short wave infrared band (SWIR at 1590–1690 nm to measure CO2 and CH4 absorptions, and the second in the near infrared (NIR at 757–768 nm to measure O2 absorptions for reference/normalisation purposes. MAMAP can be operated in both nadir and zenith geometry during the flight. Mounted on an aeroplane, MAMAP surveys areas on regional to local scales with a ground pixel resolution of approximately 29 m × 33 m for a typical aircraft altitude of 1250 m and a velocity of 200 km h−1. The retrieval precision of the measured column relative to background is typically ≲1% (1σ. MAMAP measurements are valuable to close the gap between satellite data, having global coverage but with a rather coarse resolution, on the one hand, and highly accurate in situ measurements with sparse coverage on the other hand. In July 2007, test flights were performed over two coal-fired power plants operated by Vattenfall Europe Generation AG: Jänschwalde (27.4 Mt CO2 yr−1 and Schwarze Pumpe (11.9 Mt CO2 yr−1, about 100 km southeast of Berlin, Germany. By using two different inversion approaches, one based on an optimal estimation scheme to fit Gaussian plume models from multiple sources to the data, and another using a simple Gaussian integral method, the emission rates can be determined and compared with emissions reported by Vattenfall Europe. An extensive error analysis for the retrieval's dry column results (XCO2 and XCH4 and for the two inversion methods has been performed. Both methods – the Gaussian plume model fit and the Gaussian integral method – are capable of deriving

  17. MAMAP – a new spectrometer system for column-averaged methane and carbon dioxide observations from aircraft: retrieval algorithm and first inversions for point source emission rates

    Directory of Open Access Journals (Sweden)

    J. P. Burrows

    2011-04-01

    Full Text Available MAMAP is an airborne passive remote sensing instrument designed for measuring columns of methane (CH4 and carbon dioxide (CO2. The MAMAP instrument consists of two optical grating spectrometers: One in the short wave infrared band (SWIR at 1590–1690 nm to measure CO2 and CH4 absorptions and another one in the near infrared (NIR at 757–768 nm to measure O2 absorptions for reference purposes. MAMAP can be operated in both nadir and zenith geometry during the flight. Mounted on an airplane MAMAP can effectively survey areas on regional to local scales with a ground pixel resolution of about 29 m × 33 m for a typical aircraft altitude of 1250 m and a velocity of 200 km h−1. The retrieval precision of the measured column relative to background is typically ≲ 1% (1σ. MAMAP can be used to close the gap between satellite data exhibiting global coverage but with a rather coarse resolution on the one hand and highly accurate in situ measurements with sparse coverage on the other hand. In July 2007 test flights were performed over two coal-fired powerplants operated by Vattenfall Europe Generation AG: Jänschwalde (27.4 Mt CO2 yr−1 and Schwarze Pumpe (11.9 Mt CO2 yr−1, about 100 km southeast of Berlin, Germany. By using two different inversion approaches, one based on an optimal estimation scheme to fit Gaussian plume models from multiple sources to the data, and another using a simple Gaussian integral method, the emission rates can be determined and compared with emissions as stated by Vattenfall Europe. An extensive error analysis for the retrieval's dry column results (XCO2 and XCH4 and for the two inversion methods has been performed. Both methods – the Gaussian plume model fit and the Gaussian integral method – are capable of delivering reliable estimates for strong point source emission rates, given appropriate flight patterns and detailed knowledge of wind conditions.

  18. MAMAP - a new spectrometer system for column-averaged methane and carbon dioxide observations from aircraft: retrieval algorithm and first inversions for point source emission rates

    Science.gov (United States)

    Krings, T.; Gerilowski, K.; Buchwitz, M.; Reuter, M.; Tretner, A.; Erzinger, J.; Heinze, D.; Pflüger, U.; Burrows, J. P.; Bovensmann, H.

    2011-09-01

    MAMAP is an airborne passive remote sensing instrument designed to measure the dry columns of methane (CH4) and carbon dioxide (CO2). The MAMAP instrument comprises two optical grating spectrometers: the first observing in the short wave infrared band (SWIR) at 1590-1690 nm to measure CO2 and CH4 absorptions, and the second in the near infrared (NIR) at 757-768 nm to measure O2 absorptions for reference/normalisation purposes. MAMAP can be operated in both nadir and zenith geometry during the flight. Mounted on an aeroplane, MAMAP surveys areas on regional to local scales with a ground pixel resolution of approximately 29 m × 33 m for a typical aircraft altitude of 1250 m and a velocity of 200 km h-1. The retrieval precision of the measured column relative to background is typically ≲ 1% (1σ). MAMAP measurements are valuable to close the gap between satellite data, having global coverage but with a rather coarse resolution, on the one hand, and highly accurate in situ measurements with sparse coverage on the other hand. In July 2007, test flights were performed over two coal-fired power plants operated by Vattenfall Europe Generation AG: Jänschwalde (27.4 Mt CO2 yr-1) and Schwarze Pumpe (11.9 Mt CO2 yr-1), about 100 km southeast of Berlin, Germany. By using two different inversion approaches, one based on an optimal estimation scheme to fit Gaussian plume models from multiple sources to the data, and another using a simple Gaussian integral method, the emission rates can be determined and compared with emissions reported by Vattenfall Europe. An extensive error analysis for the retrieval's dry column results (XCO2 and XCH4) and for the two inversion methods has been performed. Both methods - the Gaussian plume model fit and the Gaussian integral method - are capable of deriving estimates for strong point source emission rates that are within ±10% of the reported values, given appropriate flight patterns and detailed knowledge of wind conditions.

  19. Evaluation of crystallization behavior on the surface of nifedipine solid dispersion powder using inverse gas chromatography.

    Science.gov (United States)

    Miyanishi, Hideo; Nemoto, Takayuki; Mizuno, Masayasu; Mimura, Hisashi; Kitamura, Satoshi; Iwao, Yasunori; Noguchi, Shuji; Itai, Shigeru

    2013-02-01

    To investigate crystallization behavior on the surface of amorphous solid dispersion powder using inverse gas chromatography (IGC) and to predict the physical stability at temperatures below the glass transition temperature (T (g)). Amorphous solid dispersion powder was prepared by melt-quenching of a mixture of crystalline nifedipine and polyvinylpyrrolidon (PVP) K-30. IGC was conducted by injecting undecane (probe gas) and methane (reference gas) repeatedly to the solid dispersion at temperatures below T (g). Surface crystallization was evaluated by the retention volume change of undecane based on the observation that the surface of the solid dispersion with crystallized nifedipine gives an increased retention volume. On applying the retention volume change to the Hancock-Sharp equation, surface crystallization was found to follow a two-dimensional growth of nuclei mechanism. Estimation of the crystallization rates at temperatures far below T (g) using the Avrami-Erofeev equation and Arrhenius equation showed that, to maintain its quality for at least three years, the solid dispersion should be stored at -20°C (T (g) - 65°C). IGC can be used to evaluate crystallization behavior on the surface of a solid dispersion powder, and, unlike traditional techniques, can also predict the stability of the solid dispersion based on the surface crystallization behavior.

  20. Understanding Methane Emission from Natural Gas Activities Using Inverse Modeling Techniques

    Science.gov (United States)

    Abdioskouei, M.; Carmichael, G. R.

    2015-12-01

    Natural gas (NG) has been promoted as a bridge fuel that can smooth the transition from fossil fuels to zero carbon energy sources by having lower carbon dioxide emission and lower global warming impacts in comparison to other fossil fuels. However, the uncertainty around the estimations of methane emissions from NG systems can lead to underestimation of climate and environmental impacts of using NG as a replacement for coal. Accurate estimates of methane emissions from NG operations is crucial for evaluation of environmental impacts of NG extraction and at larger scale, adoption of NG as transitional fuel. However there is a great inconsistency within the current estimates. Forward simulation of methane from oil and gas operation sites for the US is carried out based on NEI-2011 using the WRF-Chem model. Simulated values are compared against measurements of observations from different platforms such as airborne (FRAPPÉ field campaign) and ground-based measurements (NOAA Earth System Research Laboratory). A novel inverse modeling technique is used in this work to improve the model fit to the observation values and to constrain methane emission from oil and gas extraction sites.

  1. Description and evaluation of REFIST v1.0: a regional greenhouse gas flux inversion system in Canada

    OpenAIRE

    2016-01-01

    A regional greenhouse gas flux inversion system (REFIST v1.0) is described. This paper provides a comprehensive evaluation of REFIST for three provinces in Canada that include Alberta (AB), Saskatchewan (SK) and Ontario (ON). Using year 2009 fossil fuel CO2 CarbonTracker model results as the target, the synthetic data experiment analyses examined the impacts of the errors from the Bayesian optimisation method, inversion time span, prior flux distribution, region definition and the atmospheric...

  2. Evaluation of the retention pattern on ionic liquid columns for gas chromatographic analyses of fatty acid methyl esters.

    Science.gov (United States)

    Lin, Chen-Chen; Wasta, Ziar; Mjøs, Svein A

    2014-07-11

    Fatty acid methyl esters from marine sources were analyzed by gas chromatography-mass spectrometry on three ionic liquid columns, SLB-IL61, SLB-IL82 and SLB-IL100 (Supelco). Retention indices (equivalent chain lengths) are reported for more than 100 compounds and the overlap patterns are evaluated from these data. The influence of chromatographic conditions on the retention indices of unsaturated fatty acid methyl esters is also evaluated. Compared to typical alternative phases the retention patterns on all three columns are highly dependent on the conditions. The SLB-IL61 phase had overlaps between nutritionally important fatty acids that could not be resolved by changing the chromatographic conditions. This column is therefore regarded as unsuitable for clinical and nutritional studies of the fatty acid composition, but similar overlaps may be avoided on IL82 and IL100. On all three columns double bonds close to the carboxyl group in the analytes contribute with limited retention, which makes it challenging to predict the retention of polyunsaturated fatty acid methyl esters.

  3. Dispersive surface properties of glass-ionomer cements determined by inverse gas chromatography

    Science.gov (United States)

    Andrzejewska, E.; Voelkel, A.; Andrzejewski, M.; Limanowska-Shaw, H.

    2005-05-01

    The surface properties of several glass-ionomer cements (GIC), restorative dental materials, (GC-Fuji, Chemadent G-J, Ketac Fil and Ketac Molar) were investigated for the first time by means of inverse gas chromatography. This method enables characterization of surface activity in dispersive (non-polar) and acid-base interactions. The ability of the surface of glass-ionomers to participate in dispersive interactions was expressed by the use of the dispersive component of surface free energy γsd. This parameter was determined with satisfactory precision, meaning that the values of γsd can be further used in the discussion of the influence of the type of GIC, its preparation and the storage time on the surface properties. The greatest capacity for dispersive interactions was revealed by Ketac Molar and the lowest by GC-Fuji. Dispersive interactions in the surface activity of glass-ionomers increased with increasing storage time after cement preparation.

  4. Surface Lewis acid-base properties of polymers measured by inverse gas chromatography.

    Science.gov (United States)

    Shi, Baoli; Zhang, Qianru; Jia, Lina; Liu, Yang; Li, Bin

    2007-05-18

    Surface Lewis acid-base properties are significant for polymers materials. The acid constant, K(a) and base constant, K(b) of many polymers were characterized by some researchers with inverse gas chromatography (IGC) in recent years. In this paper, the surface acid-base constants, K(a) and K(b) of 20 kinds of polymers measured by IGC in recent years are summarized and discussed, including seven polymers characterized in this work. After plotting K(b) versus K(a), it is found that the polymers can be encircled by a triangle. They scatter in two regions of the triangle. Four polymers exist in region I. K(b)/K(a) of the polymers in region I are 1.4-2.1. The other polymers exist in region II. Most of the polymers are relative basic materials.

  5. New procedure for the determination of Hansen solubility parameters by means of inverse gas chromatography.

    Science.gov (United States)

    Adamska, K; Bellinghausen, R; Voelkel, A

    2008-06-27

    The Hansen solubility parameter (HSP) seems to be a useful tool for the thermodynamic characterization of different materials. Unfortunately, estimation of the HSP values can cause some problems. In this work different procedures by using inverse gas chromatography have been presented for calculation of pharmaceutical excipients' solubility parameter. The new procedure proposed, based on the Lindvig et al. methodology, where experimental data of Flory-Huggins interaction parameter are used, can be a reasonable alternative for the estimation of HSP values. The advantage of this method is that the values of Flory-Huggins interaction parameter chi for all test solutes are used for further calculation, thus diverse interactions between test solute and material are taken into consideration.

  6. Carbonyl sulfide as an inverse tracer for biogenic organic carbon in gas and aerosol phases

    Science.gov (United States)

    de Gouw, J. A.; Warneke, C.; Montzka, S. A.; Holloway, J. S.; Parrish, D. D.; Fehsenfeld, F. C.; Atlas, E. L.; Weber, R. J.; Flocke, F. M.

    2009-03-01

    Carbonyl sulfide (COS) is a long-lived trace gas in the atmosphere with an oceanic source and a surface sink through the uptake by vegetation and soils. We demonstrate the use of COS as an inverse tracer for the impact of biogenic emissions on an air mass including the formation of secondary organic aerosol (SOA). Using airborne data from the summer of 2004 over the northeastern U.S., we find that air masses with reduced COS in the continental boundary layer had on average higher mixing ratios of biogenic VOCs (isoprene, monoterpenes, methanol) and their photo-oxidation products (methacrolein, methyl vinyl ketone, methyl furan and MPAN, a peroxyacyl nitrate derived from isoprene). Measurements of water-soluble organic carbon were only weakly correlated with COS, indicating that SOA formation from biogenic precursors was a small contribution to the total.

  7. Hydraulic Performance and Gas Behavior of a Tall Crystalline Silicotitanate Ion-Exchange Column

    Energy Technology Data Exchange (ETDEWEB)

    Welch, T.D.; Anderson, K.K.; Bostick, D.A.; Dillow, T.A.; Getting, M.W.; Hunt, R.D.; Lenarduzzi, R.; Mattus, A.J.; Taylor, P.A.; Wilmarth, W.R.

    2000-02-01

    Crystalline silicotitanate (CST) sorbent is one of several technologies being evaluated by the Savannah River Site (SRS) for removing cesium from high-level tank-waste supernatant. As currently envisioned, three large 5-ft-diam, 20-ft-high ion-exchange columns will be operated in series at a superficial velocity of 4.1 cm/min. The CST will be subjected to a high radiation field from the sorbed cesium. The tests described in this work were conducted to evaluate column hydraulics, to identify changes in the CST particles during operation, to explore how radiolytic gases generated during operation behave, and to demonstrate sluicing of CST into and out of columns.

  8. Gas chromatographic separation of fatty acid esters of cholesterol and phytosterols on an ionic liquid capillary column.

    Science.gov (United States)

    Hammann, Simon; Vetter, Walter

    2015-12-15

    Steryl esters are high molecular weight compounds (600-700g/mol) regularly present as a minor lipid class in animal and plant lipids. Different sterol backbones (e.g., cholesterol, β-sitosterol and brassicasterol) which can be esterified with various fatty acids can result in highly complex steryl ester patterns in food samples. The gas chromatographic (GC) analysis of intact steryl esters is challenging, since high elution temperatures are required for their elution. On nonpolar GC phases, steryl esters with fatty acids with differing degree of unsaturation (e.g., oleate and linoleate) cannot be separated and there are only few polar columns available with sufficient temperature stability. In this study, we used gas chromatography with mass spectrometry (GC/MS) and analyzed intact steryl esters on a commercial room temperature ionic liquid (RTIL) column which was shortened to a length of 12m. The column separated the steryl esters both by total carbon number and by degree of unsaturation of the fatty acid. For instance, cholesteryl esters with stearic acid (18:0), oleic acid (18:1n-9), linoleic acid (18:2n-6) and α-linolenic acid (18:3n-3) could be resolved (R≥1.3) from each other. By analysis of synthesized standard substances, the elution orders for different steryl backbones and different fatty acids on a given sterol backbone could be determined. Analysis of spreads and plant oils allowed to determine retention times for 37 steryl esters, although a few co-elutions were observed. The ionic liquid column proved to be well-suited for the analysis of intact steryl esters.

  9. A water column study of methane around gas flares located at the West Spitsbergen continental margin

    DEFF Research Database (Denmark)

    Gentz, Torben; Damm, Ellen; von Deimling, Jens Schneider

    2014-01-01

    L1. Our results suggest that the methane dissolved from gas bubbles is efficiently trapped below the pycnocline and thus limits the methane concentration in surface water and the air–sea exchange during summer stratification. During winter the lateral stratification breaks down and fractions...... the fate of the released gas due to dissolution of methane from gas bubbles and subsequent mixing, transport and microbial oxidation. The oceanographic data indicated a salinity-controlled pycnocline situated ∼20 m above the seafloor. A high resolution sampling program at the pycnocline at the active gas...... in the δ13CCH4 values point to a 13C depleted methane source (∼ –60‰ VPDB) being mainly mixed with a background values of the ambient water (∼–37.5‰ VPDB). A gas bubble dissolution model indicates that ∼80% of the methane released from gas bubbles into the ambient water takes place below the pycnocline...

  10. Simulation and Optimization of Strengthening the Gas-Liquid Mass Transfer Structure in Tray Column

    Directory of Open Access Journals (Sweden)

    Duan Jihai

    2015-01-01

    Full Text Available This paper presented the analysis of the effect of the mesh layers, installation height and opening rate on gas-liquid two-phase flow field by numerical simulation, which based on Euler-Euler model and identified the best liquid-gas ratio. The simulation results showed that: when the installation height of the square mesh was 25 mm and opening rate was 55.7%, the gas holdup distribution in the upper part of the mesh became higher and improved the liquid velocity distribution. Meanwhile, the gas-liquid distribution on trays was more uniform.

  11. Comprehensive two-dimensional gas chromatography for enhanced analysis of naphthas: new column combination involving permethylated cyclodextrin in the second dimension.

    Science.gov (United States)

    Adam, Frédérick; Vendeuvre, Colombe; Bertoncini, Fabrice; Thiébaut, Didier; Espinat, Didier; Hennion, Marie-Claire

    2008-01-18

    A new column association using comprehensive two-dimensional gas chromatography for the detailed molecular analysis of hydrocarbon mixtures is reported in this paper. In order to compare the impact of two different secondary columns, a novel column combination relying on a GC x 2GC system was used. This system is based on a non-polar first column (PONA) combined with both a permethylated beta-cyclodextrin (beta-Dex 120) stationary phase and a polysilphenylensiloxane (BPX 50) in the second dimension. Compared to BPX 50 stationary phase, the implementation of beta-cyclodextrin columns as the second dimension was found to improve the resolution between paraffins and naphthenes in the naphtha range but not in the middle distillate range. Attempts to improve the results and to understand the interaction mechanism remained unsuccessful. Therefore, the benefits of the beta-Dex 120-column are only demonstrated on heavy naphtha cut for the quantitation of hydrocarbons.

  12. Fabrication and characterization of microelectromechanical systems-based gas chromatography column with embedded micro-posts for separation of environmental carcinogens.

    Science.gov (United States)

    Sun, Jianhai; Cui, Dafu; Chen, Xing; Zhang, Lulu; Cai, Haoyuan; Li, Hui

    2013-05-24

    In this paper, a micro gas chromatography (μGC) column with embedded micro-posts was developed for increasing overall surface area of the columns which is able to support more of the stationary phase and reducing the effective width of the column, leading to higher separation efficiency. The proposed columns have a higher sample capacity as the overall surface area is about 3 times larger than that of open columns with the same dimensions. In order to achieve an even flow velocity in the channels, the location of the micro-posts in the linear channels and the configuration of curved channels were optimized by numerical simulation. The results have indicated that the proposed column separated 5 environmental carcinogens in less than 50s, achieved a separation efficiency of about 9500plates/m and eluted highly symmetrical Gaussian peaks.

  13. Direct determination of melamine in dairy products by gas chromatography/mass spectrometry with coupled column separation

    Energy Technology Data Exchange (ETDEWEB)

    Xu Xiaomin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou, 310028 (China); Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, 310051 (China); Ren Yiping [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, 310051 (China); Zhu Yun [Xinjiang Uygur Autonomous Region Center for Disease Control and Prevention, Urumchi, 830002 (China); Cai Zengxuan; Han Jianlong; Huang Baifen [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, 310051 (China); Zhu Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou, 310028 (China)

    2009-09-14

    A coupled capillary column system was developed for the qualitative and quantitative determination of melamine with isotope internal standard in dairy products by gas chromatography/mass spectrometry (GC/MS) without derivatization. A 30 m of DB-5ms ((5%-phenyl)-methylpolysiloxane, 0.25 mm i.d., 0.25 {mu}m df) coupled with a 1.5 m of Innowax (polyethylene glycol, 0.32 mm i.d., 0.25 {mu}m df) by a quartz capillary column connector was introduced as separation column. Three advantages were discussed for the coupled system. The sample was fortified with a ring-labeled {sup 13}C{sub 3}{sup 15}N{sub 3}-melamine as an isotope internal standard and extracted by 1% of trichloroacetic acid aqueous solution. 2.2% of lead acetate solution was then added to deposit protein in the sample matrix. After purification by cation exchange cartridge, the sample solution was directly injected and detected by GC/MS. A six-point calibration curve ranging from 0.05 to 2 mg kg{sup -1} of melamine in sample was used to establish instrument response. The recovery was 93.9-102% with relative standard deviation from 3.1 to 8.7% when isotope internal standard used. The calculated method detection limit was 0.01 mg kg{sup -1}.

  14. Optimum geometry of tuned liquid column-gas damper for control of offshore jacket platform vibrations under seismic excitation

    Science.gov (United States)

    Mousavi, Seyed Amin; Zahrai, Seyed Mehdi; Bargi, Khosrow

    2012-12-01

    In this study, the effectiveness of a tuned liquid column-gas damper, TLCGD, on the suppression of seismicinduced vibrations of steel jacket platforms is evaluated. TLCGD is an interesting choice in the case of jacket platforms because it is possible to use the structural elements as the horizontal column of the TLCGD. The objective here is to find the optimum geometric parameters, namely orientation and configuration of vertical columns, length ratio, and area ratio of the TLCGD, considering nonlinear damping of the TLCGD and water-structure interaction between the jacket platform and sea water. The effects of different characteristics of ground motion such as PGA and frequency content on the optimum geometry are also investigated and it is observed that these features have some influence on the optimum area ratio. Finally it is observed that pulse arrangement of ground acceleration is one of the most important parameters affecting the efficiency of a TLCGD. In other words, it is found that the TLCGD's capability to reduce the RMS responses depends only on the frequency content of the ground acceleration, but its capability to reduce the maximum responses depends on both the frequency content and the pulse arrangement of the ground acceleration.

  15. A DIRECT MEASUREMENT OF THE TOTAL GAS COLUMN DENSITY IN ORION KL

    Energy Technology Data Exchange (ETDEWEB)

    Plume, R. [Department of Physics and Astronomy and the Institute for Space Imaging Sciences, University of Calgary, Calgary, AB T2N 1N4 (Canada); Bergin, E. A.; Wang, S.; Crockett, N. R. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109 (United States); Phillips, T. G.; Lis, D. C. [California Institute of Technology, Cahill Center for Astronomy and Astrophysics 301-17, Pasadena, CA 91125 (United States); Caux, E. [Universite de Toulouse, UPS-OMP, IRAP, Toulouse (France); Comito, C.; Schilke, P. [Max-Planck-Institut fuer Radioastronomie, Auf dem Huegel 69, 53121 Bonn (Germany); Goldsmith, P. F., E-mail: plume@ras.ucalgary.ca [Jet Propulsion Laboratory, Caltech, Pasadena, CA 91109 (United States)

    2012-01-01

    The large number of high-J lines of C{sup 18}O available via the Herschel Space Observatory provide an unprecedented ability to model the total CO column density in hot cores. Using the emission from all the observed lines (up to J = 15-14), we sum the column densities in each individual level to obtain the total column after correcting for the population in the unobserved states. With additional knowledge of source size, V{sub LSR}, and line width, and both local thermodynamic equilibrium (LTE) and non-LTE modeling, we have determined the total C{sup 18}O column densities in the Extended Ridge, Outflow/Plateau, Compact Ridge, and Hot Core components of Orion KL to be 1.4 Multiplication-Sign 10{sup 16} cm{sup -2}, 3.5 Multiplication-Sign 10{sup 16} cm{sup -2}, 2.2 Multiplication-Sign 10{sup 16} cm{sup -2}, and 6.2 Multiplication-Sign 10{sup 16} cm{sup -2}, respectively. We also find that the C{sup 18}O/C{sup 17}O abundance ratio varies from 1.7 in the Outflow/Plateau, 2.3 in the Extended Ridge, 3.0 in the Hot Core, and to 4.1 in the Compact Ridge. This is in agreement with models in which regions with higher ultraviolet radiation fields selectively dissociate C{sup 17}O, although care must be taken when interpreting these numbers due to the size of the uncertainties in the C{sup 18}O/C{sup 17}O abundance ratio.

  16. Gas chromatographic-mass spectrometric analysis of acrylamide and acetamide in cigarette mainstream smoke after on-column injection.

    Science.gov (United States)

    Diekmann, Joerg; Wittig, Arno; Stabbert, Regina

    2008-08-01

    A method is described for the simultaneous determination of two short-chained amides, acrylamide and acetamide (classified by the International Agency for Research on Cancer as probable and possible human carcinogens, respectively), in total particulate matter using gas chromatography-on-column injection and mass spectrometric detection. Sample preparation is kept to a minimum, and the proposed analytical procedure proves to be fast, sensitive, and precise. Validation studies show good linearity with a regression coefficient of r2=.000 for both compounds. Quantitation limits are 32 ng/mL for acrylamide and 70 ng/mL for acetamide. In the particulate phase of mainstream smoke from the University of Kentucky Reference Cigarette 2R4F, 2.3 microg/cig acrylamide and 4.7 microg/cig acetamide are found; no acetamide and only .0074 microg/cig acrylamide is found in the gas phase. Possible mechanisms of formation in cigarette smoke are discussed.

  17. Gas Hold-Up, Mixing Time and Circulation Time in Internal Loop Airlift Bubble Column

    Directory of Open Access Journals (Sweden)

    Ali Abdul Rahman–Al Ezzi

    2014-01-01

    Full Text Available The effects of superficial gas in the riser (Vgr and liquid phase properties on the gas hold-up(ɛg , mixing time (Tm and circulation time (TC were studied in 8 liter internal air lift loop reactor (down comer-to-riser crosssectional area ratio = 0.249. Air was used as a gas phase. Water and four aqueous solutions of 10% concentration methanol, ethanol, (were used to simulate the behavior of non-coalescing organic liquids 50% glycerol and 2% Carboxy Methyl Cellulose (CMC were used to simulate the behavior of coalescing viscous liquids. Polyethylene-non-porous-solid particles with a concentration of (50 Kg/m3 were used as solid phase. Superficial gas velocity varied from 0.01 m/s to 0.1 m/s and air dispersed into the center of the draught tube by using a porous gas distributor. The results showed that (εg increased with increasing gas velocity and coalescence inhibition of liquid, while Tm and Tc decrease with increasing gas velocity. It was found that increasing liquid viscosity and coalescence reduces (εg but increases (Tm and (Tc. The gas holdup was correlated with dimensionless groups and independent parameter with correlation coefficient is 0.967, the following correlation is obtained.

  18. Extending the upper temperature range of gas chromatography with all-silicon microchip columns using a heater/clamp assembly.

    Science.gov (United States)

    Ghosh, Abhijit; Johnson, Jacob E; Nuss, Johnathan G; Stark, Brittany A; Hawkins, Aaron R; Tolley, Luke T; Iverson, Brian D; Tolley, H Dennis; Lee, Milton L

    2017-09-29

    Miniaturization of gas chromatography (GC) instrumentation is of interest because it addresses current and future issues relating to compactness, portability and field application. While incremental advancements continue to be reported in GC with columns fabricated in microchips (referred to in this paper as "microchip columns"), the current performance is far from acceptable. This lower performance compared to conventional GC is due to factors such as pooling of the stationary phase in corners of non-cylindrical channels, adsorption of sensitive compounds on incompletely deactivated surfaces, shorter column lengths and less than optimum interfacing to injector and detector. In this work, a GC system utilizing microchip columns was developed that solves the latter challenge, i.e., microchip interfacing to injector and detector. A microchip compression clamp was constructed to heat the microchip (i.e., primary heater), and seal the injector and detector fused silica interface tubing to the inlet and outlet ports of the microchip channels with minimum extra-column dead volume. This clamp allowed occasional operation up to 375°C and routine operation up to 300°C. The compression clamp was constructed of a low expansion alloy, Kovar™, to minimize leaking due to thermal expansion mismatch at the interface during repeated thermal cycling, and it was tested over several months for more than one hundred injections without forming leaks. A 5.9m long microcolumn with rectangular cross section of 158μm×80μm, which approximately matches a 100μm i.d. cylindrical fused silica column, was fabricated in a silicon wafer using deep reactive ion etching (DRIE) and high temperature fusion bonding; finally, the channel was coated statically with a 1% vinyl, 5% phenyl, 94% methylpolysiloxane stationary phase. High temperature separations of C10-C40 n-alkanes and a commercial diesel sample were demonstrated using the system under both temperature programmed GC (TPGC) and thermal

  19. Flare-Shaped Acoustic Anomalies in the Water Column Along the Ecuadorian Margin: Relationship with Active Tectonics and Gas Hydrates

    Science.gov (United States)

    Michaud, Francois; Proust, Jean-Noël; Dano, Alexandre; Collot, Jean-Yves; Guiyeligou, Grâce Daniella; Hernández Salazar, María José; Ratzov, Gueorgui; Martillo, Carlos; Pouderoux, Hugo; Schenini, Laure; Lebrun, Jean-Frederic; Loayza, Glenda

    2016-10-01

    With hull-mounted multibeam echosounder data, we report for the first time along the active Ecuadorian margin, acoustic signatures of water column fluid emissions and seep-related structures on the seafloor. In total 17 flare-shaped acoustic anomalies were detected from the upper slope (1250 m) to the shelf break (140 m). Nearly half of the flare-shaped acoustic anomalies rise 200-500 m above the seafloor. The base of the flares is generally associated with high-reflectivity backscatter patches contrasting with the neighboring seafloor. We interpret these flares as caused by fluid escape in the water column, most likely gases. High-resolution seismic profiles show that most flares occur close to the surface expression of active faults, deformed areas, slope instabilities or diapiric structures. In two areas tectonic deformation disrupts a Bottom Simulating Reflector (BSR), suggesting that buried frozen gas hydrates are destabilized, thus supplying free gas emissions and related flares. This discovery is important as it opens the way to determine the nature and origin of the emitted fluids and their potential link with the hydrocarbon system of the forearc basins along the Ecuadorian margin.

  20. Express analysis of explosives, chemical warfare agents and drugs with multicapillary column gas chromatography and ion mobility increment spectrometry.

    Science.gov (United States)

    Buryakov, Igor A

    2004-02-05

    Description of a gas chromatograph designed for express analysis of explosives (2,4-dinitrotoluene, 2,4,6-trinitrotoluene, pentaerythritol tetranitrate), chemical warfare agents (mustard gas, lewisite, sarin) and drugs (heroin, cocaine hydrochloride, crack) is given. The devices comprises a multicapillary chromatographic column and an ion mobility increment spectrometer (MCC-IMIS). The main analytical characteristics of an IMIS (estimated detection limit (DL), linear dynamic range (LDR), speed of response) and a chromatographic column (separation power, degree of separation, a number of possible peaks at a chromatogram section, divided by analysis time) are determined. The maximum value of DL equal to 5 pg/ml was registered for cis-alpha-LW, and the lowest one of 0.001 pg/ml was for cocaine. The maximum value of LDR equal to 1000 was registered for sarin and the lowest one of 150 was for the ions of lewisite. Speed of response of one compound detection with the IMIS was 0.7 s.

  1. Characterization of moderate ash-and-gas explosions at Santiaguito volcano, Guatemala, from infrasound waveform inversion and thermal infrared measurements

    Science.gov (United States)

    Angelis, S. De; Lamb, O. D.; Lamur, A.; Hornby, A. J.; Aulock, F. W.; Chigna, G.; Lavallée, Y.; Rietbrock, A.

    2016-06-01

    The rapid discharge of gas and rock fragments during volcanic eruptions generates acoustic infrasound. Here we present results from the inversion of infrasound signals associated with small and moderate gas-and-ash explosions at Santiaguito volcano, Guatemala, to retrieve the time history of mass eruption rate at the vent. Acoustic waveform inversion is complemented by analyses of thermal infrared imagery to constrain the volume and rise dynamics of the eruption plume. Finally, we combine results from the two methods in order to assess the bulk density of the erupted mixture, constrain the timing of the transition from a momentum-driven jet to a buoyant plume, and to evaluate the relative volume fractions of ash and gas during the initial thrust phase. Our results demonstrate that eruptive plumes associated with small-to-moderate size explosions at Santiaguito only carry minor fractions of ash, suggesting that these events may not involve extensive magma fragmentation in the conduit.

  2. Methanotrophic activity in the water column above shallow gas flares west of Prins Karls Forland, Arctic Ocean

    Science.gov (United States)

    Gründger, Friederike; Svenning, Mette M.; Niemann, Helge; Silyakova, Anna; Serov, Pavel; Pavlov, Alexey K.; Granskog, Mats A.; Ferre, Bénédicte; Carroll, JoLynn

    2016-04-01

    Numerous gas flares, interpreted to be streams of methane bubbles, were discovered in shallow waters (average water depth about 90 m) on the continental shelf west of Prins Karls Forland (Western Svalbard) in the Arctic Ocean. Gas is released from the seabed to the water column and potentially transferred into the atmosphere where it acts as a potent greenhouse gas. In order to resolve the fate of dissolved methane in the water column, we carried out grid-pattern biogeochemical measurements in the study area of 30 x 15 km. Specifically, we measured concentrations of dissolved methane and microbial methane oxidation (MOx) rates at 8 water depths at 31 sampling stations and performed 16S rRNA sequencing analysis on selected samples to characterize the microbial community composition. Availability of dissolved methane is essential for the process of microbial methane oxidation. However, our measurements reveal that high concentrations of dissolved methane in the water column do not necessarily lead to high MOx rates. Our results indicated that the presence of marine methanotrophic biomass as well as dissolved organic matter is of larger importance for the process of microbial methane oxidation. For example, we found MOx hot spots with values up to 13 nmol l-1 d-1 at bottom water depth with dissolved methane concentrations less than 160 nmol l-1. In contrast, at stations where bottom methane concentration values reached 640 nmol l-1, MOx rates were less than 0.7 nmol l-1 d-1. To interpret observed interconnection between methane concentrations and MOx rates, we use vertical distributions of seawater temperature, salinity and properties of colored dissolved organic matter (CDOM). This information helps us characterize the oceanographic setting and circulation patterns in the area, which we believe has a major impact on the origin and distribution of methanotrophic microbial biomass and methane oxidation in methanerich bottom water. This study is part of the Centre for

  3. Study of a core-shell type impact modifier by inverse gas chromatography.

    Science.gov (United States)

    Santos, J M R C A; Guthrie, J T

    2005-04-08

    Inverse gas chromatography (IGC) has been used to study the Lewis acid-base properties of a technologically and commercially important core-shell type elastomer (MBS rubber). The parameters determined were the dispersive component of the surface tension, the surface free energy, the enthalpy and the entropy of adsorption of polar and apolar probes, the surface Lewis acidity constant (Ka), and the surface Lewis basicity constant (Kb). The results show that the MBS rubber is amphoteric but strongly Lewis basic. It is weakly Lewis acidic. The results are in accord with the analysis of the molecular structure of PMMA, the shell component of this impact modifier (IM). The interactivity of this elastomer with the remaining materials in multicomponent polymeric systems is expected to be strongly influenced by the particular surface energetic properties of the MBS rubber. The results presented would contribute to the interpretation, forecast and optimization of the adhesion properties and phase preferences shown by this impact modifier when incorporated in such complex polymeric systems as polymer blends and composites.

  4. The effective surface energy of heterogeneous solids measured by inverse gas chromatography at infinite dilution.

    Science.gov (United States)

    Sun, Chenhang; Berg, John C

    2003-04-15

    Inverse gas chromatography (IGC) at infinite dilution has been widely used to access the nonspecific surface free energy of solid materials. Since most practical surfaces are heterogeneous, the effective surface energy given by IGC at infinite dilution is somehow averaged over the whole sample surface, but the rule of averaging has thus far not been established. To address this problem, infinite dilution IGC analysis was carried out on mixtures of known heterogeneity. These materials are obtained by mixing two types of solid particles with significantly different surface energies as characterized individually with IGC, and results are obtained for binary combinations in varying proportions. It is found that when all surface components have the same accessibility by probe molecules, the effective surface energy of such a heterogeneous surface is related to the surface energy distribution by a square root linear relationship, square root sigma(eff)(LW)= summation operator (i)phi(i) square root sigma(i)(LW), where sigma(i)(LW) refers to the nonspecific (Lifshitz-van der Waals) surface energy of patches i, and phi(i) to their area fraction.

  5. [Surface properties of ZuMgAl hydrotalcite-like compounds by inverse gas chromatography].

    Science.gov (United States)

    Zhou, Liangqin; Fu, Dayou; Yuan, Dong; Fan, Jinlong; Tan, Wenyuan

    2015-01-01

    The structure of ZnMgAl hydrotalcite-like compounds (ZnMgAl-HTLC) prepared by hydrothermal synthesis was studied by X-ray diffraction (XRD). With a series of polar and nonpolar molecules as probes, inverse gas chromatography (IGC) was used to measure the surface properties of ZnMgAl-HTLC. It was found that the XRD pattern of ZnMgAl-HTLC was narrow, sharp and high. The results showed that ZnMgAl-HTLC with a higher purity was obtained by hydrothermal synthesis. The surface adsorption free energy was less than zero. The surface dispersive free energy was 6.02 mJ/m2. The acid-base interaction free energy was 5.33 kJ/mol. The adsorption enthalpy was 43.6 kJ/mol, and the adsorption entropy was 0.15 kJ/mol. The IGC method is significant in the study of the surface properties of ZnMgAl-HTLC.

  6. Characterization of the surface tension and solubility parameter of epoxy resin by using inverse gas chromatography.

    Science.gov (United States)

    Shi, Fenghui; Dai, Zhishuang; Zhang, Baoyan

    2010-07-01

    Inverse gas chromatography (IGC) was used to measure the surface tension and solubility parameter of E51 epoxy resin in this work. By using the Schultz method, decane, nonane, octane and heptane were chosen as the neutral probes to calculate the dispersive surface tensions (gamma(D)). Based on the Good-van Oss equation, the specific surface tension (gamma(SP)) of E51 epoxy resin was calculated with the acidic probe of dichloromethane and the basic probe of toluene. The results showed that the gamma(D) and gamma(SP) of the E51 resin decreased linearly with the increase of temperature. According to the Flory-Huggins parameters (chi) between the resin and a series of probes, the solubility parameters (delta) of E51 resin at different temperatures were estimated using the method developed by DiPaola-Baranyi and Guillet. It was found that the values of delta of the E51 resin were 11.78, 11.57, 11.48 and 11.14 MPa1/2 at 30, 40, 50 and 60 degrees C, respectively. The dispersive component (delta(D)) and the specific component (delta(SP)) of solubility parameter at different temperatures of the E51 resin were investigated according to the relationships between surface tension, cohesion energy and solubility parameter. The results showed that the values of delta(D) were higher than those of delta(SP) for the epoxy resin, and both of them decreased with the increase of temperature.

  7. Solubility and surface thermodynamics of conducting polymers by inverse gas chromatography. III: polypyrrole chloride.

    Science.gov (United States)

    Duaij, Omar K; Alghamdi, Ali; Al-Saigh, Zeki Y

    2013-05-24

    Inverse gas chromatography, IGC, was applied to characterize conducting polypyrrole chloride (PPyCl) using twenty three solvents. IGC is able to reveal the change in the morphology, the strength of solvent-PPyCl interactions, thermodynamics parameters (χ12, Ω1(∞)), solvent and polymer solubility parameters, and molar heats of sorption, mixing and evaporation (ΔH1(s), ΔH1(∞), ΔH1(v)). The following solvents showed stronger interactions than others; yet, none of these solvents are good solvents for PPyCl: dodecane among the alkane family, tetrahydrofuran and methyl ethyl ketone among the oxy and keto group, dichloromethane among the chlorinated group up to 120°C and chloroform at 180°C, and toluene among the cyclic and aromatic group. Overall, the groups showed higher affinities to PPyCl are: acetates, oxy and cyclic, and chlorinated groups. Comprehensive solvents and PPyCl solubility parameters are obtained. The latter showed that PPyCl is not soluble in any solvent used.

  8. [Determination of solubility parameters for asymmetrical dicationic ionic liquids by inverse gas chromatography].

    Science.gov (United States)

    Wang, Jun; Yang, Xuzhao; Wu, Jinchao; Song, Hao; Zou, Wenyuan

    2015-12-01

    Inverse gas chromatographic (IGC) technology was used to determine the solubility parameters of three asymmetrical dicationic ionic liquids ([ PyC5Pi] [ NTf2]2, [MpC5Pi] [NTf2]2 and [PyC6Pi] [NTf2]2) at 343.15-363.15 K. Five alkanes were applied as test probes including octane (n-C8) , decane (n-C10), dodecane (n-C12), tetradecane (n-C14), hexadecane (n-C16). Some thermodynamic parameters were obtained by IGC data analysis, such as the specific retention volumes of the solvents (V0(g)), the molar enthalpies of sorption (ΔHs(1)), the partial molar enthalpies of mixing at infinite dilution (ΔH∞91)), the molar enthalpies of vaporization (ΔH)v)), the activity coefficients at infinite dilution (Ω∞(1)), and Flory-Huggins interaction parameters (χ∞(12)) between ionic liquids and probes. The solubility parameters (δ2) of the three dicationic ionic liquids at room temperature (298.15 K) were 28.52-32.66 (J x cm(-3)) ½. The solubility parameters (δ2) of cationic structure with 4-methyl morpholine are bigger than those of the cationic structure with pyridine. The bigger the solubility parameter (δ2) is, the more the carbon numbers of linking group of the ionic liquids are. The results are of great importance to the study of the solution behavior and the applications of ionic liquid.

  9. Gas-liquid mass transfer coefficient of methane in bubble column reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jaewon; Ha, Kyoung-Su; Lee, Jinwon; Kim, Choongik [Sogang University, Seoul (Korea, Republic of); Yasin, Muhammad; Park, Shinyoung; Chang, In Seop [Gwangju Institute of Science and Technology (GIST), Gwangju (Korea, Republic of); Lee, Eun Yeol [Kyung Hee University, Yongin (Korea, Republic of)

    2015-06-15

    Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k{sub L}a). The feasibility of the new reactor was demonstrated by measuring k{sub L}a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k{sub L}a value of 102.9 h{sup -1} was obtained.

  10. Three years of greenhouse gas column-averaged dry air mole fractions retrieved from satellite – Part 1: Carbon dioxide

    Directory of Open Access Journals (Sweden)

    O. Schneising

    2008-07-01

    Full Text Available Carbon dioxide (CO2 and methane (CH4 are the two most important anthropogenic greenhouse gases. SCIAMACHY on ENVISAT is the first satellite instrument whose measurements are sensitive to concentration changes of the two gases at all altitude levels down to the Earth's surface where the source/sink signals are largest. We have processed three years (2003–2005 of SCIAMACHY near-infrared nadir measurements to simultaneously retrieve vertical columns of CO2 (from the 1.58 μm absorption band, CH4 (1.66 μm and oxygen (O2 A-band at 0.76 μm using the scientific retrieval algorithm WFM-DOAS. We show that the latest version of WFM-DOAS, version 1.0, which is used for this study, has been significantly improved with respect to its accuracy compared to the previous versions while essentially maintaining its high processing speed (~1 min per orbit, corresponding to ~6000 single measurements, and per gas on a standard PC. The greenhouse gas columns are converted to dry air column-averaged mole fractions, denoted XCO2 (in ppm and XCH4 (in ppb, by dividing the greenhouse gas columns by simultaneously retrieved dry air columns. For XCO2 dry air columns are obtained from the retrieved O2 columns. For XCH4 dry air columns are obtained from the retrieved CO2 columns because of better cancellation of light path related errors compared to using O2 columns retrieved from the spectrally distant O2 A-band. Here we focus on a discussion of the XCO2 data set. The XCH4 data set is discussed in a separate paper (Part 2. In order to assess the quality of the retrieved XCO2 we present comparisons with Fourier Transform Spectroscopy (FTS XCO2 measurements at two northern hemispheric mid-latitude ground stations. To assess the quality globally, we present detailed comparisons with

  11. Spatial Variability in Column CO2 Inferred from High Resolution GEOS-5 Global Model Simulations: Implications for Remote Sensing and Inversions

    Science.gov (United States)

    Ott, L.; Putman, B.; Collatz, J.; Gregg, W.

    2012-01-01

    Column CO2 observations from current and future remote sensing missions represent a major advancement in our understanding of the carbon cycle and are expected to help constrain source and sink distributions. However, data assimilation and inversion methods are challenged by the difference in scale of models and observations. OCO-2 footprints represent an area of several square kilometers while NASA s future ASCENDS lidar mission is likely to have an even smaller footprint. In contrast, the resolution of models used in global inversions are typically hundreds of kilometers wide and often cover areas that include combinations of land, ocean and coastal areas and areas of significant topographic, land cover, and population density variations. To improve understanding of scales of atmospheric CO2 variability and representativeness of satellite observations, we will present results from a global, 10-km simulation of meteorology and atmospheric CO2 distributions performed using NASA s GEOS-5 general circulation model. This resolution, typical of mesoscale atmospheric models, represents an order of magnitude increase in resolution over typical global simulations of atmospheric composition allowing new insight into small scale CO2 variations across a wide range of surface flux and meteorological conditions. The simulation includes high resolution flux datasets provided by NASA s Carbon Monitoring System Flux Pilot Project at half degree resolution that have been down-scaled to 10-km using remote sensing datasets. Probability distribution functions are calculated over larger areas more typical of global models (100-400 km) to characterize subgrid-scale variability in these models. Particular emphasis is placed on coastal regions and regions containing megacities and fires to evaluate the ability of coarse resolution models to represent these small scale features. Additionally, model output are sampled using averaging kernels characteristic of OCO-2 and ASCENDS measurement

  12. Spatial variability in column CO2 inferred from high resolution GEOS-5 global model simulations: Implications for remote sensing and inversions

    Science.gov (United States)

    Ott, L.; Putman, W. M.; Pawson, S.; Collatz, G. J.; Gregg, W. W.

    2012-12-01

    Column CO2 observations from current and future remote sensing missions represent a major advancement in our understanding of the carbon cycle and are expected to help constrain source and sink distributions. However, data assimilation and inversion methods are challenged by the difference in scale of models and observations. OCO-2 footprints represent an area of several square kilometers while NASA's future ASCENDS lidar mission is likely to have an even smaller footprint. In contrast, the resolution of models used in global inversions are typically hundreds of kilometers wide and often cover areas that include combinations of land, ocean and coastal areas and areas of significant topographic, land cover, and population density variations. To improve understanding of scales of atmospheric CO2 variability and representativeness of satellite observations, we will present results from a global, 10-km simulation of meteorology and atmospheric CO2 distributions performed using NASA's GEOS-5 general circulation model. This resolution, typical of mesoscale atmospheric models, represents an order of magnitude increase in resolution over typical global simulations of atmospheric composition allowing new insight into small scale CO2 variations across a wide range of surface flux and meteorological conditions. The simulation includes high resolution flux datasets provided by NASA's Carbon Monitoring System Flux Pilot Project at half degree resolution that have been downscaled to 10-km using remote sensing datasets. Probability distribution functions are calculated over larger areas more typical of global models (100-400 km) to characterize subgrid-scale variability in these models. Particular emphasis is placed on coastal regions and regions containing megacities and fires to evaluate the ability of coarse resolution models to represent these small scale features. Additionally, model output are sampled using averaging kernels characteristic of OCO-2 and ASCENDS measurement

  13. Evaluation and application of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry for complex sample analysis.

    Science.gov (United States)

    Denawaka, Chamila J; Fowlis, Ian A; Dean, John R

    2014-04-18

    An evaluation of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS) has been undertaken to assess its applicability for the determination of 32 volatile compounds (VCs). The key experimental variables of sample incubation time and temperature have been evaluated alongside the MCC-GC variables of column polarity, syringe temperature, injection temperature, injection volume, column temperature and carrier gas flow rate coupled with the IMS variables of temperature and drift gas flow rate. This evaluation resulted in six sets of experimental variables being required to separate the 32 VCs. The optimum experimental variables for SHS-MCC-GC-IMS, the retention time and drift time operating parameters were determined; to normalise the operating parameters, the relative drift time and normalised reduced ion mobility for each VC were determined. In addition, a full theoretical explanation is provided on the formation of the monomer, dimer and trimer of a VC. The optimum operating condition for each VC calibration data was obtained alongside limit of detection (LOD) and limit of quantitation (LOQ) values. Typical detection limits ranged from 0.1ng bis(methylthio)methane, ethylbutanoate and (E)-2-nonenal to 472ng isovaleric acid with correlation coefficient (R(2)) data ranging from 0.9793 (for the dimer of octanal) through to 0.9990 (for isobutyric acid). Finally, the developed protocols were applied to the analysis of malodour in sock samples. Initial work involved spiking an inert matrix and sock samples with appropriate concentrations of eight VCs. The average recovery from the inert matrix was 101±18% (n=8), while recoveries from the sock samples were lower, that is, 54±30% (n=8) for sock type 1 and 78±24% (n=6) for sock type 2. Finally, SHS-MCC-GC-IMS was applied to sock malodour in a field trial based on 11 volunteers (mixed gender) over a 3-week period. By applying the SHS-MCC-GC-IMS database, four VCs were

  14. A Miniaturized Laser Heterodyne Radiometer for Greenhouse Gas Measurements in the Atmospheric Column

    Science.gov (United States)

    Steel, Emily Wilson

    2015-01-01

    Laser Heterodyne Radiometry is a technique adapted from radio receiver technology has been used to measure trace gases in the atmosphere since the 1960s.By leveraging advances in the telecommunications industry, it has been possible to miniaturize this technology.The mini-LHR (Miniaturized Laser Heterodyne Radiometer) has been under development at NASA Goddard Space flight Center since 2009. This sun-viewing instrument measures carbon dioxide and methane in the atmospheric column and operates in tandem with an AERONET sun photometer producing a simultaneous measure of aerosols. The mini-LHR has been extensively field tested in a range of locations ranging in the continental US as well as Alaska and Hawaii and now operates autonomously with sensitivities of approximately 0.2 ppmv and approximately10 ppbv, for carbon dioxide and methane respectively, for 10 averaged scans under clear sky conditions.

  15. Greenhouse Gas Emissions of Indianapolis using a High-Density Surface Tower Network and an Atmospheric Inversion

    Science.gov (United States)

    Lauvaux, T.; Miles, N. L.; Davis, K. J.; Richardson, S.; Deng, A.; Sarmiento, D. P.; Wu, K.; Sweeney, C.; Karion, A.; Hardesty, R. M.; Brewer, A.; Turnbull, J. C.; Iraci, L. T.; Hillyard, P. W.; Podolske, J. R.; Gurney, K. R.; Patarasuk, R.; Cambaliza, M. O. L.; Shepson, P. B.; Whetstone, J. R.

    2014-12-01

    The Indianapolis Flux Experiment (INFLUX) was designed to develop and evaluate methods of detection and attribution of greenhouse gas fluxes from urban environments. Determination of greenhouse gas fluxes and uncertainty bounds is essential for the evaluation of the effectiveness of mitigation strategies. Indianapolis is intended to serve as a test bed for these methods; the results will inform efforts at measuring emissions from urban centers worldwide, including megacities. The generally accepted method for determining urban greenhouse gas emissions is inventories, which are compiled from records of land use and human activity. Atmospheric methods, in which towers are instrumented with sensors to measure greenhouse gas mole fractions and these data are used in an inversion model, have the potential to provide independent determination of emissions. The current INFLUX observation network includes twelve in-situ tower-based, continuous measurements of CO2. A subset of five towers additionally measure CH4, and a different subset measure CO. The subset measuring CO also include weekly flask samples of a wide variety of trace gases including 14CO2. Here we discuss the observed urban spatial and temporal patterns in greenhouse gas mole fraction in Indianapolis, with the critical result being the detectability of city emissions with this high-density network. We also present the first atmospheric inversion results for both CO2 and CH4, compare these results to inventories, and discuss the effects of critical assumptions in the inversion framework. The construction of unbiased atmospheric modeling systems and well-defined prior errors remains an important step in atmospheric emissions monitoring over urban areas. In order to minimize transport model errors, we developed a WRF-Chem FDDA modeling system ingesting surface and profile measurements of horizontal mean wind, temperature, and moisture. We demonstrate the impact of the meteorological data assimilation system on

  16. Glass transition of adsorbed stereoregular PPMA by inverse gas chromatography at infinite dilution

    Science.gov (United States)

    Hamieh, T.; Rezzaki, M.; Grohens, Y.; Schultz, J.

    1998-10-01

    In this paper, we used inverse gas chromatography (IGC) at infinite dilution that proved to be a powerful technique to determine glass transition and other transitions of PMMA adsorbed on α-alumina. We highlighted the glass transition temperature of the system PMMA/α-Al2O3 with defined polymer tacticity at various covered surface fractions. Thus, the Tg of the adsorbed isotactic PMMA increases strongly as compared to the bulk value. The study of the physical chemical properties of PMMA/α-alumina revealed an important difference in the acidic and basic behaviour, in Lewis terms, of aluminium oxide covered by various concentrations of PMMA. It appears that there is a stabilisation of the physical chemical properties of PMMA/α-Al2O3 for a surface coverage above 50%. This study also highlighted an important effect of the tacticity of the polymer on the acid-base character of the system PMMA/Al2O3. Dans cet article, nous montrons que la chromatographie gazeuse inverse (CGI) à dilution infinie se révèle être une technique très intéressante pour la détermination de la transition vitreuse de polymères stéréoréguliers adsorbés sur des substrats solides tels que l'alumine. Nous avons mis en évidence des transitions attribuées aux phénomènes de relaxation béta, transition vitreuse et autres transitions des systèmes PMMA/Al2O3 de tacticité définie à différents taux de recouvrement. Ainsi, la Tg du PMMA isotactique adsorbé augmente de façon significative par rapport a celle du polymère massique. L'étude des propriétés physico-chimiques du système PMMA/Al2O3, révèle une différence importante dans le comportement acido-basique, au sens de Lewis, de l'alumine pour de taux de recouvrement en PMMA variables. Il apparaît qu'il y a stabilisation des propriétés physico-chimiques de PMMA/Al2O3 pour un taux de recouvrement en PMMA supérieur à 50 %. Cette étude a montré également une influence importante de la tacticité du polymère sur le

  17. [The rapid analysis of polychlorinated quaterphenyls in blood using different diameter capillary column with the high-resolution gas chromatograph high-resolution mass spectrometer].

    Science.gov (United States)

    Yasutake, Daisuke; Ashizuka, Yuki; Hori, Tsuguhide; Kurokawa, Youichi; Kajiwara, Jumboku; Hirata, Teruaki; Ishiguro, Yasuhisa; Iida, Takao; Uchi, Hiroshi; Furue, Masutaka

    2011-04-01

    The polychlorinated quaterphenyl (PCQ) concentrations in blood are important discriminative parameters in yusho patient. In this study, a rapid analytical method for PCQ using different diameter capillary column (rapid-Rtx65TG) with high-resolution gas chromatograph high-resolution mass spectrometer (HRGC/HRMS) instead of the gas chromatograph electron capture detector (ECD/GC) was developed. Using different diameter capillary columns, the analysis time of the HRGC/HRMS was drastically shortened, and the detection sensitivity was improved. In the rapid-Rtx65TG column, a small-bore capillary column (length 1m, I.D. 0.1mm) was connected with the inlet side of the GC, and behind that column, a large-bore capillary column (length 15mm, I.D. 0.53mm) for octadecachloroquaterphenyl (ODCQ) analysis was connected. In the HRGC/HRMS measurement of ODCQ by the rapid-Rtx65TG column, the minimum limit of detection for the apparatus was 0.4 pg, and the minimum limit of determination for the blood was 0.008 ppb. On ECD/GC in the conventional method and HRGC/HRMS in this study, the PCQ concentration in blood including yusho patients and yusho suspected persons was almost equivalent.

  18. Murphree efficiency for calculating column height in CO{sub 2} absorption from atmospheric gas using amines

    Energy Technology Data Exchange (ETDEWEB)

    Oi, L.E. [Telemark Univ. College, Porsgrunn (Norway)

    2009-07-01

    Murphree efficiencies (EMURPHREE) are used to improve the calculation of column height for carbon dioxide (CO{sub 2}) removal. This presentation reported on a study in which EMURPHREE was calculated for typical conditions for CO{sub 2} absorption into monoethanol amine (MEA) from atmospheric exhaust using a structured packing with specific area 250 m{sup 2}/m{sup 3}. When the inlet gas and liquid temperature was 40 degrees C, the temperatures at top stage and bottom stage conditions were 44 and 42 degrees C. The EMURPHREE calculations were based on a pseudo first order reaction between CO{sub 2} and MEA. The calculated EMURPHREE increased as temperature increased. EMURPHREE was also calculated with approximation methods from literature. The deviation in calculated EMURPHREE was less than 5 per cent when the inlet temperature was 40 degrees C. The deviation increased with temperature and CO{sub 2} loading. It was concluded that Murphree efficiencies are as accurate as more rigorous models, as long as the absorption is in the pseudo first order regime. A more rigorous model has the same uncertainties in estimation of effective specific area, CO{sub 2} solubilities and in the concentration of molecular amine in the bulk liquid. Murphree efficiencies for CO{sub 2} absorption calculations have an advantage because they can be used in robust stage by stage column models that are currently used in commercial process simulation programs.

  19. Contribution of tuned liquid column gas dampers to the performance of offshore wind turbines under wind, wave, and seismic excitations

    Science.gov (United States)

    Bargi, Khosrow; Dezvareh, Reza; Mousavi, Seyed Amin

    2016-09-01

    The main intention of the present study is to reduce wind, wave, and seismic induced vibrations of jackettype offshore wind turbines (JOWTs) through a newly developed vibration absorber, called tuned liquid column gas damper (TLCGD). Using a Simulink-based model, an analytical model is developed to simulate global behavior of JOWTs under different dynamic excitations. The study is followed by a parametric study to explore efficiency of the TLCGD in terms of nacelle acceleration reduction under wind, wave, and earthquake loads. Study results indicate that optimum frequency of the TLCGD is rather insensitive to excitation type. In addition, while the gain in vibration control from TLCGDs with higher mass ratios is generally more pronounced, heavy TLCGDs are more sensitive to their tuned frequency such that ill-regulated TLCGD with high mass ratio can lead to destructive results. It is revealed that a well regulated TLCGD has noticeable contribution to the dynamic response of the JOWT under any excitation.

  20. A new efficient empirical correlation for filtrate flux in slurry bubble column reactor of a gas-to-liquid process

    Energy Technology Data Exchange (ETDEWEB)

    Hemmati, Mohammad Reza [Entekhab Petrochemical Co., Tehran (Iran, Islamic Republic of); Khodagholi, Mohammad Ali [Research Institute of Petroleum Industry, Tehran (Iran, Islamic Republic of)

    2015-12-15

    Gas to Liquid has recently become of great interest. In this technology slurry bubble column reactors are favored for many reasons. Separation of liquid wax from the slurry is still a major problem that may be done by internal or external filtration. A system of sintered metal candle filters are designed and operated to collect experimental data of internal filtration. Data for 4 and 8 micron filter elements with different pressure differences and kinematic viscosity were collected. Data analysis revealed that these data could be correlated as a simple function of time, pressure drop and kinematic viscosity. This new and efficient correlation shows excellent ability to reproduce original data at moderate filtration conditions, but it is less precious in severe conditions. It was understood that main reason for this behavior is different filtrate flux regimes through filter media pores, led to inability of a single correlation to fit both regimes properly.

  1. [Surface characterization of urushiol-titanium chelate polymers by inverse gas chromatography].

    Science.gov (United States)

    Xu, Yanlian; Lin, Jinhuo; Xia, Jianrong; Hu, Binghuan

    2011-03-01

    Urushiol-titanium chelate polymer (UTP), the reaction product of urushiol with titanium compound, is a special eco-friendly polymer with excellent performances, such as strong acids-resistance, strong alkalis-resistance, salt solution-resistance and several organic solvent-resistance. Inverse gas chromatography (IGC) was used to measure the dispersive component of surface free energy (gamma(s)d) and the Lewis acid-base parameters of UTP in this work. The gamma(s)d and the acid/base characters of UTP' surfaces were estimated by the retention time with different non-polar and polar probes at infinite dilution region. n-Pentane (C5), n-hexane (C6), n-heptane (C7), n-octane (C8) and n-nonane (C9) were chosen as the non-polar probes to characterize the gamma(s)d. Trichloromethane (CHCl3), tetrahydrofuran (THF) and acetone were chosen as polar probes to detect the Lewis acid-base parameters. The specific free energy (deltaG(a)AB) and the enthalpy (deltaH(a)AB) of adsorption corresponding to acid-base surface interactions were determined. By correlating deltaH(a)AB with the donor and acceptor numbers of the probes, the acidic (K(a)) and the basic (K(b)) parameters of the samples were calculated. The results showed that the dispersive components of the free energy of UTP were 37.68, 33.53, 35.92, 24.01 and 31.32 mJ/m2 at 70, 80, 90, 100 and 110 degrees C, respectively. The Lewis acidic number K(a) of UTP was 0.185 3, and the Lewis basic number K(b) was 0.966 2. The results were of great importance to the study of the surface properties and the applications for urushiol-metal chelate polymers.

  2. Trace gas column retrieval from IR nadir spectra - a model study for SCIAMACHY

    Science.gov (United States)

    de Beek, R.; Buchwitz, M.; Rozanov, V. V.; Burrows, J. P.

    2004-01-01

    The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY (SCIAMACHY) is part of the European satellite ENVISAT launched at 1st March 2002. It is a follow-on instrument of the Global Ozone Monitoring Experiment (GOME) flying on ERS-2 and, compared to GOME, has extended capabilities. Using measurements of the direct extra-terrestrial solar spectrum and sun-light reflected and scattered by the earth atmosphere or surface SCIAMACHY detects atmospheric absorption of several trace species absorbing in spectral regions from the ultraviolet to the near infrared (240-2380 nm). Vertical columns of H 2O, N 2O, CO, and CH 4 can be retrieved using SCIAMACHY Channel 8 near-infrared nadir measurements. In this study, selected atmospheric and instrument specific errors relevant for the retrieval are analysed. Spectral windows of Channel 8 are considered, which are currently used for the operational near-real-time processing. For this purpose, spectral error patterns have been simulated as well as sun-normalised model radiances for nadir scanning mode, the latter using the radiative transfer model SCIATRAN. Focus are the polarisation sensitivity and dark signals of the instrument. Further on, accuracy estimates for a number of different atmospheric scenarios are presented.

  3. Full-Column Greenhouse Gas Sampling 2012-2014 Final Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, M. L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, C. [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.

    2016-01-01

    The vertical distributions of CO2, CH4, and other gases provide important constraints when determining terrestrial and ocean sources and sinks of carbon and other biogeochemical processes in the Earth system. The U.S. Department of Energy's (DOE) Office of Biological and Environmental Research and the National Oceanic and Atmospheric Administration's Earth System Research Laboratory to quantify the vertically resolved distribution of atmospheric carbon-cycle gases(CO2, CH4 ) within approximately 99% of the atmospheric column at the DOE ’s Atmospheric Radiation Measurement Southern Great Plains (SGP) site in Oklahoma . During the 2012 to 2014 campaign period, 12 successful Air C ore flights were conducted from the SGP site . In addition to providing critical data for evaluating remote sensing and earth system models, valuable lessons were learned that motivate improvements to the sampling and recovery systems and campaign logistics . With the launch of the Orbiting Carbon Observatory - 2 (OCO - 2) and Greenhouse gases Observing Satellite ( GOSAT ) satellites, we look forward to proposing additional sampling and analysis efforts at the SGP site and at other sites to characterize the vertical distribution of CO2, CH4 over time and space.

  4. Detection of fusion residues produced by inverse kinematic reactions using a gas-filled split-pole spectrograph

    CERN Document Server

    Liang, J F; Beene, J R; Bierman, J D; Galindo-Uribarri, A; Gomez-Campo, J D; Gross, C J; Halbert, M L; Harding, T J; McNab, A I; McNeal, S P; Varner, R L; Zhao, K

    1999-01-01

    A focal plane detector has been constructed for detecting fusion residues in a gas-filled Enge split-pole spectrograph. It provides position, timing and energy for particle identification. With a timing channel plate detector in the target chamber, the particle time-of-flight can be measured. This detector system is particularly suitable for studying fusion-evaporation reactions in inverse kinematics. (author)

  5. Exploring reverse shape selectivity and molecular sieving effect of metal-organic framework UIO-66 coated capillary column for gas chromatographic separation.

    Science.gov (United States)

    Chang, Na; Yan, Xiu-Ping

    2012-09-28

    Metal-organic frameworks (MOFs) which offer a variety of topologies, porous networks and high surface areas are promising and have potential for the applications of specific adsorption, isomerization, catalysis and separation. UIO-66 is the first MOF that has been observed to have reverse shape selectivity. However, such reverse shape selectivity of MOFs has never been explored for capillary gas chromatographic separation. Here we report the fabrication of MOF UIO-66 coated capillary column and exploration of the reverse shape selectivity and molecular sieving effect of such column for capillary gas chromatographic separation of alkane isomers and benzene homologues with excellent selectivity and precision. The adsorption enthalpies and entropies on the interaction between hydrocarbons and UIO-66 were measured to illustrate the energy effect on the separation of alkane isomers and benzene homologues on the UIO-66 coated capillary column. UIO-66 coated capillary column gave preferential retention of branched alkane isomers over their linear isomer, showing reverse shape selectivity, making UIO-66 coated capillary column attractive for capillary gas chromatographic separation of alkane isomers. iso-Propylbenzene (branched) eluted after n-propylbenzene on the UIO-66 coated capillary column again shows reverse shape selectivity. However, much bulkier 1,3,5-trimethylbenzene eluted earlier than n-propylbenzene and iso-propylbenzene on the UIO-66 coated capillary column, exhibiting molecular sieving effect. The combination of reverse shape selectivity with molecular sieving effect makes the UIO-66 coated capillary column promising for the separation of structural isomers. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Characterization of underivatized lipid biomarkers from microorganisms with pyrolysis short-column gas chromatography/ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, A.P. (Army Chemical Research, Aberdeen Proving Ground, MD (USA)); McClennen, W.H.; Dworzanski, J.P.; Meuzelaar, H.L.C. (Univ. of Utah, Salt Lake City (USA))

    1990-12-01

    A microvolume Curie-point pyrolysis short-column (5 m) gas chromatography/mass spectrometry (Py-Gc/MS) procedure was developed for the characterization of various lipid moieties in microorganisms. High linear flow rates (approximately 175 cm/s) characterized the GC conditions in order to effect an efficient chromatographic transfer and elution of the underivatized diglycerides and monoglycerides, and small modifications were necessary to the ion trap MS system in order for it to accommodate the relatively high gas load. During a typical analysis run anhydrodiacylglycerides eluted within a 5-6-min time frame. Gram-positive bacilli and Gram-negative species were differentiated from each other by the pyrolysis patterns of their lipid components. In spite of the complexity of the analyte, a straightforward visual analysis was achieved with the aid of simple computerized data display procedures. These procedures included examination of (1) total ion current (TIC) profiles of the lipid region of the reconstructed chromatogram, (2) the integrated mass spectrum of this region, (3) selected reconstructed ion chromatograms (RICs), (4) RIC intensity distributions, and (5) corresponding mass spectra. An appealing aspect of the lipid data reduction procedure is that most of it can be accomplished visually without requiring computerized pattern recognition techniques.

  7. Gas chromatography for in situ analysis of a cometary nucleus. II. Analysis of permanent gases and light hydrocarbons with a carbon molecular sieve porous layer open tubular column.

    Science.gov (United States)

    Szopa, C; Sternberg, R; Coscia, D; Raulin, F; Vidal-Madjar, C

    2000-12-22

    Considering the severe constraints of space instrumentation, a great improvement for the in situ gas chromatographic (GC) determination of permanent and noble gases in a cometary nucleus is the use of a new carbon molecular sieve porous layer open tubular (PLOT) column called Carbobond. No exhaustive data dealing with this column being available, studies were carried out to entirely characterize its analytical performances, especially when used under the operating conditions of the cometary sampling and composition (COSAC) experiment of the European Space Agency (ESA) Rosetta space mission to be launched in 2003 for a rendezvous with comet 46 P/Wirtanen in 2011. The high efficiency and speed of analysis of this column at both atmospheric and vacuum outlet column pressure is demonstrated, and the kinetic mass transfer contribution of this carbon molecular sieve adsorbent is calculated. Besides, differential adsorption enthalpies of several gases and light hydrocarbons were determined from the variation of retention volume with temperature. The data indicate close adsorption behaviors on the Carbobond porous layer adsorbent and on the carbon molecular sieve Carboxen support used to prepare the packed columns. Moreover, taking into account the in situ operating conditions of the experiment, a study of two columns with different porous layer thicknesses allowed one to optimize the separation of the target components and to select the column parameters compatible with the instrument constraints. Comparison with columns of similar selectivity shows that these capillary columns are the first ones able to perform the same work as the packed and micro-packed columns dedicated to the separation of this range of compounds in GC space exploration.

  8. TOXICOLOGICAL ANALYSIS OF WHOLE-BLOOD SAMPLES BY MEANS OF BOND-ELUT CERTIFY COLUMNS AND GAS-CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

    NARCIS (Netherlands)

    ZWEIPFENNING, PGM; WILDERINK, AHCM; HORSTHUIS, P; FRANKE, JP; DEZEEUW, RA

    1994-01-01

    The application of Bond-Elut Certify solid-phase extraction columns to the systematic toxicological analysis of whole blood was evaluated. The reproducibility of the extraction was tested with thirteen drugs varying in physico-chemical properties. Analysis was performed with capillary gas chromatogr

  9. TOXICOLOGICAL ANALYSIS OF WHOLE-BLOOD SAMPLES BY MEANS OF BOND-ELUT CERTIFY COLUMNS AND GAS-CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

    NARCIS (Netherlands)

    ZWEIPFENNING, PGM; WILDERINK, AHCM; HORSTHUIS, P; FRANKE, JP; DEZEEUW, RA

    1994-01-01

    The application of Bond-Elut Certify solid-phase extraction columns to the systematic toxicological analysis of whole blood was evaluated. The reproducibility of the extraction was tested with thirteen drugs varying in physico-chemical properties. Analysis was performed with capillary gas

  10. Renewed methane increase (2007-2014): contribution of oil and natural gas emissions determined from methane and ethane column observations

    Science.gov (United States)

    Hausmann, Petra; Sussmann, Ralf; Smale, Dan

    2016-04-01

    Harmonized time series of column-averaged mole fractions of atmospheric methane and ethane over the period 1999-2014 are derived from solar Fourier transform infrared (FTIR) measurements at the Zugspitze summit (47° N, 2964 m a.s.l.) and at Lauder (45° S, 370 m a.s.l.). Long-term trend analysis reveals a consistent renewed methane increase since 2007 of 6.2 [5.6, 6.9] ppb yr-1 at the Zugspitze and 6.0 [5.3, 6.7] ppb yr-1 at Lauder (95 % confidence intervals). Several recent studies provide pieces of evidence that the renewed methane increase is most likely driven by two main factors: (i) increased methane emissions from tropical wetlands, followed by (ii) increased thermogenic methane emissions due to growing oil and natural gas production. Here, we quantify the magnitude of the second class of sources, using long-term measurements of atmospheric ethane as tracer for thermogenic methane emissions. In 2007, after years of weak decline, the Zugspitze ethane time series shows the sudden onset of a significant positive trend (2.3 [1.8, 2.8] × 10-2 ppb yr-1 for 2007-2014), while a negative trend persists at Lauder after 2007 (-0.4 [-0.6, -0.1] × 10-2 ppb yr-1). Zugspitze methane and ethane time series are significantly correlated for the period 2007-2014 and can be assigned to thermogenic methane emissions with an ethane-to-methane ratio of 10-21 %. We present optimized emission scenarios for 2007-2014 derived from an atmospheric two-box model. From our trend observations we infer a total ethane emission increase over the period 2007-2014 from oil and natural gas sources of 1-11 Tg yr-1 along with an overall methane emission increase of 24-45 Tg yr-1. Based on these results, the oil and natural gas emission contribution C to the renewed methane increase is deduced using three different emission scenarios with dedicated ranges of methane-to-ethane ratios (MER). Reference scenario 1 assumes an oil and gas emission combination with MER = 3.3-7.6, which results in a

  11. Inverse gas chromatography for natural fibre characterisation: Identification of the critical parameters to determine the Brunauer-Emmett-Teller specific surface area.

    Science.gov (United States)

    Legras, A; Kondor, A; Heitzmann, M T; Truss, R W

    2015-12-18

    Inverse gas chromatography (IGC) is an alternative technique to determine the specific surface area of natural fibres. Natural fibres have a complex surface chemistry and unique microstructure that challenge the current capabilities to perform surface characterisation. This study investigated the influence of multiple parameters on the measured Brunauer-Emmett-Teller (BET) specific surface area for samples of flax, kenaf and BioMid(®) cellulose fibres using IGC. The BET surface area of kenaf and flax differed with 0.51m(2)g(-1) and 1.35m(2)g(-1) respectively, the former being similar to the cellulose fibres (0.54m(2)g(-1)). The data was calculated under conditions where the BET equation showed good linearity (R(2)⩾0.995). Repeatability was excellent so that two runs sufficed to obtain representative BET surface area values. The findings showed the choice of solvent was important for all specimens to avoid any misleading data comparison due to molecular orientation effects that impact the adsorbent-adsorbate interactions. The higher surface area of the flax sample, and its higher variability, was correlated with a higher surface roughness observed under optical microscopy. Packing the chromatography column with long or chopped fibres produced results that were statistically insignificant.

  12. Dispersive Surface Energy and Acid-Base Parameters of Tosylate Functionalized Poly(ethylene glycol via Inverse Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Feyza Sesigur

    2014-01-01

    Full Text Available An inverse gas chromatographic (IGC study of the sorption properties of poly(ethylene glycol modified with tosylate (PEG-TOS was presented. PEG-TOS was synthesized via the tosylation of the corresponding poly(ethylene glycol (PEG with p-toluenesulfonyl chloride in the basic medium. The synthesized PEG-Tos was characterized by FTIR-ATR and 1HNMR techniques. The retention diagrams of n-hexane, n-heptane, n-octane, n-nonane, n-decane, dichloromethane, chloroform, acetone, tetrahydrofuran, ethyl acetate, and ethanol on the PEG and PEG-Tos were plotted at temperatures in K between 303 and 373 by inverse gas chromatography technique. The dispersive component of the surface-free energy, γSD, of studied adsorbent surface was estimated using retention times of different nonpolar organics in the infinite dilution region. Thermodynamic parameters of adsorption (free energy, ΔGAS, enthalpy, ΔHAS, and entropy, ΔSAS, dispersive components of the surface energies, γSD, and the acid, KA, and base, KD, constants for the PEG and PEG-Tos were calculated and the results were discussed.

  13. Atmospheric inverse modeling with known physical bounds: an example from trace gas emissions

    Directory of Open Access Journals (Sweden)

    S. M. Miller

    2014-02-01

    the relative merits of each. This paper investigates the applicability of several approaches to bounded inverse problems. A common method of data transformations is found to unrealistically skew estimates for the examined example application. The method of Lagrange multipliers and two Markov chain Monte Carlo (MCMC methods yield more realistic and accurate results. In general, the examined MCMC approaches produce the most realistic result but can require substantial computational time. Lagrange multipliers offer an appealing option for large, computationally intensive problems when exact uncertainty bounds are less central to the analysis. A synthetic data inversion of US anthropogenic methane emissions illustrates the strengths and weaknesses of each approach.

  14. Studies of Trace Gas Chemical Cycles Using Observations, Inverse Methods and Global Chemical Transport Models

    Science.gov (United States)

    Prinn, Ronald G.

    2001-01-01

    For interpreting observational data, and in particular for use in inverse methods, accurate and realistic chemical transport models are essential. Toward this end we have, in recent years, helped develop and utilize a number of three-dimensional models including the Model for Atmospheric Transport and Chemistry (MATCH).

  15. Investigation of error sources in regional inverse estimates of greenhouse gas emissions in Canada

    Directory of Open Access Journals (Sweden)

    E. Chan

    2015-08-01

    Full Text Available Inversion models can use atmospheric concentration measurements to estimate surface fluxes. This study is an evaluation of the errors in a regional flux inversion model for different provinces of Canada, Alberta (AB, Saskatchewan (SK and Ontario (ON. Using CarbonTracker model results as the target, the synthetic data experiment analyses examined the impacts of the errors from the Bayesian optimisation method, prior flux distribution and the atmospheric transport model, as well as their interactions. The scaling factors for different sub-regions were estimated by the Markov chain Monte Carlo (MCMC simulation and cost function minimization (CFM methods. The CFM method results are sensitive to the relative size of the assumed model-observation mismatch and prior flux error variances. Experiment results show that the estimation error increases with the number of sub-regions using the CFM method. For the region definitions that lead to realistic flux estimates, the numbers of sub-regions for the western region of AB/SK combined and the eastern region of ON are 11 and 4 respectively. The corresponding annual flux estimation errors for the western and eastern regions using the MCMC (CFM method are -7 and -3 % (0 and 8 % respectively, when there is only prior flux error. The estimation errors increase to 36 and 94 % (40 and 232 % resulting from transport model error alone. When prior and transport model errors co-exist in the inversions, the estimation errors become 5 and 85 % (29 and 201 %. This result indicates that estimation errors are dominated by the transport model error and can in fact cancel each other and propagate to the flux estimates non-linearly. In addition, it is possible for the posterior flux estimates having larger differences than the prior compared to the target fluxes, and the posterior uncertainty estimates could be unrealistically small that do not cover the target. The systematic evaluation of the different components of the

  16. Investigation of error sources in regional inverse estimates of greenhouse gas emissions in Canada

    Science.gov (United States)

    Chan, E.; Chan, D.; Ishizawa, M.; Vogel, F.; Brioude, J.; Delcloo, A.; Wu, Y.; Jin, B.

    2015-08-01

    Inversion models can use atmospheric concentration measurements to estimate surface fluxes. This study is an evaluation of the errors in a regional flux inversion model for different provinces of Canada, Alberta (AB), Saskatchewan (SK) and Ontario (ON). Using CarbonTracker model results as the target, the synthetic data experiment analyses examined the impacts of the errors from the Bayesian optimisation method, prior flux distribution and the atmospheric transport model, as well as their interactions. The scaling factors for different sub-regions were estimated by the Markov chain Monte Carlo (MCMC) simulation and cost function minimization (CFM) methods. The CFM method results are sensitive to the relative size of the assumed model-observation mismatch and prior flux error variances. Experiment results show that the estimation error increases with the number of sub-regions using the CFM method. For the region definitions that lead to realistic flux estimates, the numbers of sub-regions for the western region of AB/SK combined and the eastern region of ON are 11 and 4 respectively. The corresponding annual flux estimation errors for the western and eastern regions using the MCMC (CFM) method are -7 and -3 % (0 and 8 %) respectively, when there is only prior flux error. The estimation errors increase to 36 and 94 % (40 and 232 %) resulting from transport model error alone. When prior and transport model errors co-exist in the inversions, the estimation errors become 5 and 85 % (29 and 201 %). This result indicates that estimation errors are dominated by the transport model error and can in fact cancel each other and propagate to the flux estimates non-linearly. In addition, it is possible for the posterior flux estimates having larger differences than the prior compared to the target fluxes, and the posterior uncertainty estimates could be unrealistically small that do not cover the target. The systematic evaluation of the different components of the inversion

  17. Comparison of column phase configurations for comprehensive two dimensional gas chromatographic analysis of crude oil and bitumen

    Energy Technology Data Exchange (ETDEWEB)

    Tran, T.C.; Harynuk, J.; Marriott, P. [RMIT University, Melbourne (Australia). Dept. of Applied Chemistry; Logan, G.A.; Grosjean, E. [Geoscience Australia, Canberra (Australia); Ryan, D. [Charles Sturt University, Wagga Wagga (Australia). School of Science and Technology

    2006-09-15

    An inverted phase (polar to non-polar) column set has been compared with a non-polar to polar column set for the GC x GC separation of petroleum hydrocarbons. This column configuration is shown to provide greatly enhanced resolution for less polar compounds and makes greater use of the two dimensional separation space. It improves resolution of a greater number of components within one analysis and offers new possibilities for crude oil fingerprinting. (Author)

  18. Gas-Filled Hollow Core Fiber Lasers Based on Population Inversion

    Science.gov (United States)

    2013-12-05

    levels of C2H2 with the pump ( optical parametric oscillator in the telecom C band) and observed lasing transitions. The fiber ends were housed in...FA9550-10-1-0515 FA9550-10-1-0515 AFOSR unlimited Hollow-core Optical Fiber Gas LASer (HOFGLAS) have been created, and explored in pulsed mode with...were created. HOFGLAS, Optically -pumped gas lasers, photonic crystal fiber , microstructured fiber , hollow-core fiber , mid-IR lasers, IR lasers, fiber

  19. 气液两相逆流状态下金属板波纹填料塔内液体流动分布%LIQUID FLOW DISTRIBUTION IN GAS-LIQUID COUNTER-CONTACTING PACKED COLUMN

    Institute of Scientific and Technical Information of China (English)

    高瑞昶; 宋宝东; 袁孝竞

    1999-01-01

    According to the structure of Mellapak type packing, liquid flow and mixing mechanisms were analyzed in gas-liquid counter-contacting packed column. A new liquid flow distribution mathematical model , specific for Mellapak type packing columns, was presented. Experimental data of the liquid flow distribution measurements agreed quite well with the theoretical prediction. Furthermore, the effects of gas initial maldistribution and gas load on liquid flow distribution were discussed, and the wall zone liquid flow was preliminarily studied.

  20. Gas chromatography for in situ analysis of a cometary nucleus V. Study of capillary columns' robustness submitted to long-term reduced environmental pressure conditions.

    Science.gov (United States)

    Szopa, C; Sternberg, R; Coscia, D; Goesmann, F; Gomes, R; Legrand, S; Jerome, M; Meierhenrich, U J; Raulin, F

    2014-11-14

    With the European Space Agency's Rosetta space mission to comet 67P/Churyumov-Gerasimenko, a gas chromatograph, part of the COmetary Sampling And Composition (COSAC) experiment, travelled for about 10 years in the interplanetary medium before operating at the surface of the cometary nucleus in November 2014. During its journey in space, the instrument was exposed to the constraining conditions of the interplanetary medium, including reduced environmental pressures. In order to estimate the potential influence of this severe condition on the chromatographic capillary columns, their stationary phase and the subsequent separation capability, a set of flight spare columns were kept under reduced environmental pressure in the laboratory for the same duration as the probe sent to the comet. The columns' analytical performances were evaluated recently and compared to the original ones obtained just before the launch of the Rosetta probe. The results presented here show that the chromatographic performances of the spare chromatographic columns were not altered in time. From this result, it can be expected that the flight instrument will perform nominally for the analysis of the first cometary nucleus sample to be collected ever, and that the preparation of the interpretation of the data to be taken at the cometary surface nucleus can be done through calibration of these spare columns, and other spare components of the instrument. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Spiral multicapillary columns

    Science.gov (United States)

    Efimenko, A. P.; Naumenko, I. I.; Soboleva, V. K.

    2008-08-01

    It was shown in a theoretical study and confirmed by experiment that a spiral multicapillary column had maximum efficiency if the bunch of capillaries was additionally coiled around its longitudinal axis to produce an integral number of coils. This technique made it possible to manufacture gas-chromatographic columns with performance as high as 12 to 16 thousand theoretical plates. These columns can find various applications, especially if quick separation is required.

  2. Novel pre-fractionation method of trans fatty acids by gas chromatography with silver-ion cartridge column.

    Science.gov (United States)

    Goto, Hirofumi; Shionoya, Noriko; Sugie, Megumi; Tominaga, Makoto; Shimelis, Olga; Taniguchi, Makoto; Igarashi, Tomoji; Hirata, Yoshiaki

    2012-01-01

    We developed a novel pre-separation method of trans fatty acids (TFAs) using a silver-ion cartridge column and GC. As a preliminary study, a mixture of fatty acid methyl esters consisting of saturated, cis-unsaturated, and trans-unsaturated fatty acids was dissolved in dichloromethane and loaded onto a Bond Elut SCX ion-exchange cartridge column that was converted to the silver-ion form. The column was then eluted with dichloromethane to obtain the saturated fatty acids, dichloromethane/ethyl acetate (90/10) for the trans mono-ene, dichloromethane/ethyl acetate (65/35) for the cis mono-ene, dichloromethane/acetone (60/40) for the trans di-ene, and acetone/acetonitrile (80/20) for the others. Satisfactory separation of the cis/trans isomers was confirmed by GC analysis. To generalize this technique, the elution conditions of the ready-to-use Discovery Ag-ION SPE cartridge column were also optimized. Both cartridge columns had good separation, recovery, and repeatability. Peer laboratory verification was carried out between two laboratories using different production lots of the ready-to-use cartridge column, and the robustness of the product and reproducibility of the method were found to be satisfactory. This technique is therefore a powerful tool not only for routine analyses of TFAs in oils, fats, and foods but also for detailed analyses of TFAs in various research fields.

  3. LIQUID PHASE FLOW ESTIMATION IN GAS-LIQUID TWO-PHASE FLOW USING INVERSE ANALYSIS AND PARTICLE TRACKING VELOCIMETRY

    Institute of Scientific and Technical Information of China (English)

    CHENG Wen; MURAI Yuichi; SASAKI Toshio; YAMAMOTO Fujio

    2004-01-01

    An inverse analysis algorithm is proposed for estimating liquid phase flow field from measurement data of bubble motion. This kind of technology will be applied in future for various estimation of fluid flow in rivers, lakes, sea surface flow, and also microscopic channel flow as the problem-handling in civil, mechanical, electronic, and chemical engineering. The relationship between the dispersion motion and the carrier phase flow is governed and expressed by the translational motion equation of spherical dispersion. The equation consists of all the force components including inertia, added inertia, drag, lift, pressure gradient force and gravity force. Using this equation enables us to estimate the carrier phase flow structure using only the data of the dispersion motion. Whole field liquid flow structure is also estimated using spatial or temporal interpolation method. In order to verify this principle, the Taylor-Green vortex flow, and the Karman vortex shedding from a square cylinder have been chosen. The results show that the combination of the inverse analysis and Particle Tracking Velocimetry (PTV) with the spatio-temporal post-processing algorithm could reconstruct well the carrier phase flow of the gas-liquid two-phase flow.

  4. Moment tensor inversion for two micro-earthquakes occurring inside the Háje gas storage facilities, Czech Republic

    Science.gov (United States)

    Benetatos, Christoforos; Málek, Jiří; Verga, Francesca

    2013-04-01

    Broadband data from the Příbram seismological network was used to investigate the source of two earthquakes, with magnitudes M w = 0.2 and 0.4 respectively, occurring in the period of October-November 2009 in the Háje natural gas storage area (Czech Republic). Both events were located inside the limits of the storage area and at depths similar to those of the underground caverns where the gas is stored. We applied an inversion technique using the software ISOLA for moment tensor retrieval in order to assess the source process of both events and recognize whether a significant isotropic component existed that could be interpreted as a possible cavern collapse. We also performed an uncertainty analysis so as to confirm the reliability of the focal mechanism solutions and we controlled the consistency between the inverted focal mechanisms and those calculated using the P-waves first motions. Our results showed that the nodal plane orientation, the centroid depth, and the magnitude remained stable. Furthermore, we calculated synthetic waveforms for collapse-type ruptures and compared them with the original records. The match between the synthetic and the original data was very poor supporting the interpretation of the shear character of the events. The combination of the inversion results, which indicated significant double-couple components and of the synthetic tests, which supported the inexistence of an isotropic component at the source, led to the conclusion that the possibility of rocks falling from the ceiling of the caverns or a cavern collapse is highly unlikely.

  5. 气-液-固三相逆流化床动力学研究%Kinetic Study on Gas-Liquid-Solid Three Phases Inverse Fluidized Bed

    Institute of Scientific and Technical Information of China (English)

    丁洁

    2016-01-01

    A gas-liquid-solid three phases inverse fluidized bed with 0.152 m inner diameter and 2.5 m height was employed to investigate the hydrodynamics. Effect of gas and liquid velocities and particle density (polyethylene and polypropylene) on the individual phase holdup and the minimum liquid fluidization velocity was determined. The results show that the minimum liquid fluidization velocity decreases with increasing of gas velocity in the gas-liquid-solid three phases inverse fluidized bed. The gas and liquid and solid holdups increase with increasing of the gas or liquid velocity in the gas-liquid-solid three phases inverse fluidized bed.%在内径0.152 m,高2.5 m的气-液-固三相逆流化床中系统研究了动力学特性。获得了气体和液体速度及聚乙烯和聚丙烯颗粒密度对各相含率和最小液体流化速度的影响规律。研究发现随着气体速度的增加,液体最小流化速度降低;随着气体或液体速度增加,气体、液体和固体含率均增加。

  6. The Study on the Alteration of Simulated HLLW Glass in Aqueous Media by Inverse Gas Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhentao; Gan, Xueying; Yuan, Wenyi; Wang, Lei; Xing, Haiqing [China Institute of Atomic Energy, P.O.Box 275-93, Beijing, 102413 (China); Balard, Henri [Laboratoire de Chimie Physique, Ecole Nationale Superieure de Chimie de Mulhouse, 3 rue Alfred Werner, 68057 Mulhouse (France)

    2008-07-01

    There exist webs of fissures inside the glass block accessible to underground water and theses fissures will influence the alteration of the glass significantly. It is very necessary to study the fissure surface properties of the glass under deep geological conditions. The alteration tests were conducted using the simulated high level radioactive glass powder immersed in Beishan (candidate disposal site) underground water with S/V ratio of 8000 m{sup -1} at 150 deg. C and 90 deg. C for different periods. After immersion, the glass powder was filtered and dried at 120 deg. C for 3 hours. The surface properties of the dried glass powder were evaluated by inverse chromatography. The results showed that the specific surface area of the glass increases abruptly at the beginning of immersion and then increase slowly afterwards. At higher immersion temperature, the secondary phase is condensing crystals; at the lower immersion temperature, the secondary phases were loosely 'islands' with cracks or fissures. (authors)

  7. Adsorption isotherms of some alkyl aromatic hydrocarbons and surface energies on partially dealuminated Y faujasite zeolite by inverse gas chromatography.

    Science.gov (United States)

    Kondor, Anett; Dallos, András

    2014-10-03

    Adsorption isotherm data of some alkyl aromatic hydrocarbons (benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene) measured in the temperature range of 423-523K on a partially dealuminated faujasite type DAY F20 zeolite by inverse gas chromatography are presented in this work. The temperature dependent form of Tóth's equation has been fitted to the multiple temperature adsorption isotherms of benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene with standard deviations of 4.6, 5.0, 5.9, 4.3, 5.1 and 6.3mmolkg(-1) and coefficients of determinations (r(2)) of 0.977, 0.971, 0.974, 0.975, 0.991 and 0.991, respectively. The gas-solid equilibria and modeling were interpreted on the basis of the interfacial properties of the zeolite, by dispersive, specific and total surface energy heterogeneity profiles and distributions of the adsorbent measured by surface energy analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Analysis of essential oils and fragrances with a new generation of highly inert gas chromatographic columns coated with ionic liquids.

    Science.gov (United States)

    Cagliero, Cecilia; Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara

    2017-04-28

    In the fields of essential oils and fragrances, samples often consist of mixtures of compounds with similar structural and physical characteristics (e.g. mono- and sesquiterpenoids), whose correct identification closely depends on the synergic combination of chromatographic and mass spectral data. This sample complexity means that new GC stationary phases with different selectivities are continually being investigated. Ionic liquids (ILs) are of great interest as GC stationary phases in this field because of their selectivity (significantly different than that of currently phases) and their high temperature stability. A first generation of IL GC columns was found to be competitive when applied to these field, in terms of selectivity and efficiency, compared to conventional columns (polydimethylsiloxane, (e.g. OV-1), methyl-polysiloxane 5%-phenyl (e.g. SE-52), 7%-cyanopropyl, 7%-phenyl polysiloxane (e.g. OV-1701), and polyethylen glycol (e.g. PEG-20M). However, these columns showed significant activity towards polar or active analytes, which primarily affected their quantitative performance. A new generation of highly-inactive columns coated with three of the most widely-used ionic liquid GC stationary phases has recently been introduced; these phases are SLB-IL60i (1,12-di(tripropylphosphonium) dodecane bis(trifluoromethylsulfonyl) imide [NTf2], SLB-IL76i (tri-(tripropylphosphonium-hexanamido)-triethylamine [NTf2]), and SLB-IL111i (1,5-di (2,3-dimethyllimidazolium) pentane [NTf2]). This study carefully tested the new inert IL columns, in view of their routine application in the fragrance and essential oil fields. They were found to have unusually high selectivity, comparable to that of first-generation IL columns, while their inertness and efficiency were competitive with those of currently-used conventional columns. The IL column performance of first and second generations was compared, through the quali-quantitative analysis of components in a group of different

  9. Evidence of Fluid/Gas Along the Backthrust Offshore Central Sumatra from Seismic Full Waveform Inversion

    Science.gov (United States)

    Singh, S. C.; Huot, G.

    2014-12-01

    The Sumatra subduction zone is one of the most seismically active zones on the earth and has experienced great earthquakes in the last decade, including one of the largest earthquakes of the 21st century on December 26, 2004 (M 9.3) producing a devastating tsunami. Geodetic and seismological studies suggest that a part of the subduction is still fully locked and may produce a great earthquake up to Mw=9 in the coming future. In order to understand the earthquake and subduction zone processes, we applied elastic full waveform inversion (FWI) on 50km deep seismic reflection data from Benkulu forearc basin. Data were acquired in partnership with CGG in 2009 using a 15 km ultra-long offset streamer, with shots every 50m and receivers every 12.5m. Unlike usual exploration data, the streamer was dived at 22.5m and the source was triggered at 15m. These characteristics provided wide aperture and low frequencies to the data which are required for FWI. To match our modelling with the observed data before applying FWI, we first estimated the source wavelet from simulated far-offset signature. Then, the same pass-band filter was applied to both the source and the observed data from 1 to 15 Hz frequency bandwidth. Additionally, an f-k filter was applied to the real data to remove the remaining swell noise up to 4 Hz, without losing any useful signal. Our starting 2D Vp model was found by applying traveltime tomography to a smooth 1D model. Our Vs model was linked by empirical relationship to our Vp model. By inverting first for far-offset refraction to recover the background velocity model and using a multi-scale strategy by going from 1Hz to 15Hz, we image the forearc basin down to 10km depth. We highlight the presence of a 10km wide low velocity structure at 3km depth. The sharp velocity change from 4km/s to 2km/s indicates the presence of gaz or fluid which could come from the mantle through the backthrust fault. The complexity of the sea floor makes the reflection

  10. Utilization of exhaust gas from predistillation column of methanol plant%甲醇装置预精馏塔放空气的利用

    Institute of Scientific and Technical Information of China (English)

    乔思怀; 周文生; 齐辉; 马新广; 王会升

    2012-01-01

    The non-condensable gas from the predistillation column of methanol plants was seldom utilized, but discharged to air directly, that could cause safety and environmental problems. Recycling of this gas, which contained mainly carbon dioxide, to natural gas reformer to increase the hydrogen/carbon ratio of the syngas in a natural gas-based methanol plant was made, and some questions referring to the technique were discussed. Reuse of the exhaust gas could reduce carbon dioxide emission and increase methanol output.%甲醇装置预精馏塔排放的不凝气大部分没有得到利用而是直接放空,存在安全隐患、污染环境的问题.在一个天然气甲醇厂中将该主要含二氧化碳的不凝气循环回天然气转化炉作为原料,提高所得合成气的氢碳比,讨论了该循环利用技术中涉及的一些问题.该不凝气的利用降低了二氧化碳排放,增加了甲醇产量.

  11. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection.

    Science.gov (United States)

    Nakamoto, Akihiro; Nishida, Manami; Saito, Takeshi; Kishiyama, Izumi; Miyazaki, Shota; Murakami, Katsunori; Nagao, Masataka; Namura, Akira

    2010-02-19

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d(5) was used as an internal standard. The linear ranges were 0.01-5.0 microg mL(-1) for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 microg mL(-1) for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation > or = 0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 microg mL(-1) of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio > or = 3) in urine was 5 ng mL(-1) for MA and MDMA and 10 ng mL(-1) for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.

  12. Modeling and simulation of a pseudo-two-phase gas-liquid column reactor for thermal hydrocracking of petroleum heavy fractions

    Directory of Open Access Journals (Sweden)

    E.M. Matos

    2002-07-01

    Full Text Available This work presents a model to predict the behavior of velocity, gas holdup and local concentration fields in a pseudo-two-phase gas-liquid column reactor applied for thermal hydrocracking of petroleum heavy fractions. The model is based on the momentum and mass balances for the system, using an Eulerian-Eulerian approach. Using the k-epsilon model,fluid dynamics accounts for both laminar and turbulent flows, with discrete small bubbles (hydrogen flowing in a continuous pseudohomogeneous liquid phase (oil and catalyst particles. The petroleum is assumed to be a mixture of pseudocomponents, grouped by similar chemical structural properties, and the thermal hydrocracking is taken into account using a kinetic network based on these pseudocomponents.

  13. Evaluation of Gas Retention in Waste Simulants: Intermediate-Scale Column and Open-Channel-Depth Tests

    Energy Technology Data Exchange (ETDEWEB)

    Powell, Michael R.; Gauglitz, Phillip A.; Denslow, Kayte M.; Fischer, Christopher M.; Heldebrant, David J.; Prowant, Matthew S.; Sande, Susan; Davis, James M.; Telander, Monty R.

    2014-02-14

    Gas generation in Hanford’s radioactive waste storage tanks can lead to gas accumulation within the layer of settled solids (sludge) at the tank bottom. The gas, which may be hazardous and/or flammable, is formed principally by radiation-driven chemical reactions. Accumulation of these gases within the sludge increases the sludge-layer volume, which decreases the available tank volume for waste storage. Further, accumulation of large amounts of gas in the sludge can potentially result in a relatively rapid release of the accumulated gas if the sludge-layer density is reduced to less than that of the overlying sludge or that of the supernatant liquid. The potential for rapid release of large amounts of hazardous and/or flammable gases is a safety hazard that needs to be managed. Accordingly, a thorough understanding is needed of the circumstances that can lead to problematic gas accumulation in sludge layers. The Deep-Sludge Gas Release Event Project (DSGREP) is tasked with developing an improved understanding of these gas release events.

  14. Column flotation

    Energy Technology Data Exchange (ETDEWEB)

    Kohmuench, J.N.; Norrgran, D.A.; Luttrell, E.; Luttrell, G.H. [Virginia Tech. (United States)

    2008-04-15

    Over the last decade, column flotation has been recognised in the industry to be most efficient and economical means of recovering fine coal while maximizing product grade. When designed properly, flotation columns provide a high combustible recovery while maintaining a low product ash. The paper looks at the benefits of using column flotation for fine coal recovery. 2 refs., 5 figs.

  15. Effect of impregnating agent and relative humidity on surface characteristics of sorbents determined by inverse gas chromatography.

    Science.gov (United States)

    Kasperkowiak, M; Kołodziejek, J; Strzemiecka, B; Voelkel, A

    2013-05-03

    Sorbents that potentially can be used for separation of the products of biotechnological conversion of glycerol were examined. Properties of Zeolite 5A, resins: Amberlite, Diaion and their samples impregnated with an aqueous solutions of 1,2,3-propanetriol, 1,3-propanediol, 2,3-butanediol, acetic acid, succinic acid and model fermentation broth were investigated. Because surface properties will probably depend on the ambient humidity the IGC experiments were carried out under different conditions of relative humidity RH=0, 40 and 80%. Activity of the sorbents surface was expressed by the value of the dispersive component of the free surface energy. Inverse gas chromatography was also used to express acid-base properties of materials described by KA and KD parameters. The changes in the activity of investigated sorbents significantly varied depending on the type of impregnating agent. Moreover, the obtained results demonstrate that humidity can strongly influence, in some cases, the dispersive component of the free surface energy and the ability to specific interactions (KA and KD).

  16. An exploration of inter-relationships between contact angle, inverse phase gas chromatography and triboelectric charging data.

    Science.gov (United States)

    Ahfat, N M; Buckton, G; Burrows, R; Ticehurst, M D

    2000-01-01

    Surfaces of pharmaceutical powders have been assessed using contact angle, inverse phase gas chromatography (IGC) and triboelectric (electrostatic) charging techniques. The suitability of the Dynamic Angle Tester (DAT), an instrument based on the sessile drop technique, in determining contact angles and then the surface energy of pharmaceutical powders was assessed. The dispersive components of the surface energy of powders determined from the DAT and IGC method ranked the powders in the same order. The dispersive component values obtained by IGC were, as expected, higher than those from the DAT, due to IGC probing the highest energy sites on the powder surface. IGC and triboelectric studies allow materials to be characterised in terms of their electron donating-accepting tendencies, so inter-relationships between the data from the two techniques were explored. Although the data set was limited, there appeared to be a correlation between the charges developed by the powders on contact with stainless steel and the ratio of the electron-donating to electron-accepting tendencies of the materials as obtained from IGC.

  17. Determination of surface heterogeneity of D-mannitol by sessile drop contact angle and finite concentration inverse gas chromatography.

    Science.gov (United States)

    Ho, Raimundo; Hinder, Steven J; Watts, John F; Dilworth, Sarah E; Williams, Daryl R; Heng, Jerry Y Y

    2010-03-15

    The sensitivity of two techniques in tracking changes in surface energetics was investigated for a crystalline excipient, D-mannitol. Macroscopic crystals of D-mannitol were grown from saturated water solution by slow cooling, and sessile drop contact angle was employed to measure the anisotropic surface energy. The facet-specific surface energy was consistent with localised hydroxyl group concentrations determined by X-ray photoelectron spectroscopy (XPS), and was also in excellent agreement with the surface energy distribution of the powder form of mannitol measured via a new methodology using inverse gas chromatography (IGC) at finite concentrations. The gamma(SV)(d) was found to vary between 39.5 mJ/m(2) and 44.1 mJ/m(2) for contact angle and between 40 mJ/m(2) and 49 mJ/m(2) for IGC measurements. We report here, a high level of surface heterogeneity on the native mannitol crystal surfaces. When the surfaces of both D-mannitol samples (powder and large single crystals) were modified by dichlorodimethylsilane to induce surface hydrophobicity, both IGC and contact angle revealed a homogeneous surface due to functionalisation of mannitol crystal surface with methyl groups resulting in gamma(SV)(d) of approximately 34 mJ/m(2). It was shown that both IGC and contact angle techniques are able to detect surface chemical variations and detailed surface energetic distribution.

  18. Surface Energy Determined by Inverse Gas Chromatography as a Tool to Investigate Particulate Interactions in Dry Powder Inhalers.

    Science.gov (United States)

    Das, Shyamal C; Tucker, Ian G; Stewart, Peter J

    2015-01-01

    Dry powder inhalers (DPIs) usually contain drug particles energy of particles. Inverse gas chromatography (IGC) has been used to determine the surface energy of powder particles used in DPI to characterize materials and to understand aerosolization behaviour. Early studies used an infinite dilution technique to determine nonpolar surface energy and free energy of adsorption for polar interactions separately. Although some correlations were observed with the change in nonpolar surface energy before and after micronization, milling and storage, a lack of consistency in the change of free energy of adsorption was common. Moreover, a consistent relationship between complex de-agglomeration behaviour and surface energy has not been established and there are even some examples of negative correlation. In fact, nonpolar surface energy at infinite dilution is an incomplete representation of powder surface characteristics. The techniques for measuring polar surface energy, total surface energy and surface energy distribution have provided more revealing information about surface energetics of powders. Surface energy distributions determined by IGC or surface energy analyser have been successfully used to understand energetic heterogeneity of surfaces, characterize different polymorphs and understand changes due to micronization, structural relaxation, dry coating and storage. Efforts have been made to utilize surface energy distribution data to calculate powder strength distribution and to explain complex de-agglomeration behaviour of DPI formulations.

  19. Surface properties of calcium and magnesium oxide nanopowders grafted with unsaturated carboxylic acids studied with inverse gas chromatography.

    Science.gov (United States)

    Maciejewska, Magdalena; Krzywania-Kaliszewska, Alicja; Zaborski, Marian

    2012-09-28

    Inverse gas chromatography (IGC) was applied at infinite dilution to evaluate the surface properties of calcium and magnesium oxide nanoparticles and the effect of surface grafted unsaturated carboxylic acid on the nanopowder donor-acceptor characteristics. The dispersive components (γ(s)(D)) of the free energy of the nanopowders were determined by Gray's method, whereas their tendency to undergo specific interactions was estimated based on the electron donor-acceptor approach presented by Papirer. The calcium and magnesium oxide nanoparticles exhibited high surface energies (79 mJ/m² and 74 mJ/m², respectively). Modification of nanopowders with unsaturated carboxylic acids decreased their specific adsorption energy. The lowest value of γ(s)(D) was determined for nanopowders grafted with undecylenic acid, approximately 55 mJ/m². The specific interactions were characterised by the molar free energy (ΔG(A)(SP)) and molar enthalpy (ΔH(A)(SP)) of adsorption as well as the donor and acceptor interaction parameters (K(A), K(D)).

  20. Determination of the solubility parameter of ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate by inverse gas chromatography.

    Science.gov (United States)

    Ma, Xiaohong; Wang, Qiang; Li, Xiaoping; Tang, Jun; Zhang, Zhengfang

    2015-11-01

    Thermodynamic properties of ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM] BF4) were determined via inverse gas chromatography (IGC). Two groups of solvents with different chemical natures and polarities were used to obtain information about [BMIM] BF4-solvent interactions. The specific retention volume, molar heat of sorption, weight fraction activity coefficient, Flory-Huggins interaction parameter as well as solubility parameter were also determined in a temperature range of 333 - 373 K. The results showed that the selected solvents n-C10 to n-C12, carbon tetrachloride, cyclohexane and toluene were poor solvents for [BMIM] BF4, while dichloromethane, acetone, chloroform, methyl acetate, ethanol and methanol were favorite solvents for [BMIM] BF4. In addition, the solubility parameter of [ BMIM] BF4 was determined as 23.39 (J/cm3)0.5 by the extrapolation at 298 K. The experiment proved that IGC was a simple and accurate method to obtain the thermodynamic properties of ionic liquids. This study could be used as a reference to the application and research of the ionic liquids.

  1. Slurry bubble column hydrodynamics

    Science.gov (United States)

    Rados, Novica

    Slurry bubble column reactors are presently used for a wide range of reactions in both chemical and biochemical industry. The successful design and scale up of slurry bubble column reactors require a complete understanding of multiphase fluid dynamics, i.e. phase mixing, heat and mass transport characteristics. The primary objective of this thesis is to improve presently limited understanding of the gas-liquid-solid slurry bubble column hydrodynamics. The effect of superficial gas velocity (8 to 45 cm/s), pressure (0.1 to 1.0 MPa) and solids loading (20 and 35 wt.%) on the time-averaged solids velocity and turbulent parameter profiles has been studied using Computer Automated Radioactive Particle Tracking (CARPT). To accomplish this, CARPT technique has been significantly improved for the measurements in highly attenuating systems, such as high pressure, high solids loading stainless steel slurry bubble column. At a similar set of operational conditions time-averaged gas and solids holdup profiles have been evaluated using the developed Computed Tomography (CT)/Overall gas holdup procedure. This procedure is based on the combination of the CT scans and the overall gas holdup measurements. The procedure assumes constant solids loading in the radial direction and axially invariant cross-sectionally averaged gas holdup. The obtained experimental holdup, velocity and turbulent parameters data are correlated and compared with the existing low superficial gas velocities and atmospheric pressure CARPT/CT gas-liquid and gas-liquid-solid slurry data. The obtained solids axial velocity radial profiles are compared with the predictions of the one dimensional (1-D) liquid/slurry recirculation phenomenological model. The obtained solids loading axial profiles are compared with the predictions of the Sedimentation and Dispersion Model (SDM). The overall gas holdup values, gas holdup radial profiles, solids loading axial profiles, solids axial velocity radial profiles and solids

  2. Slow photon amplification of gas-phase ethanol photo-oxidation in titania inverse opal photonic crystals

    Science.gov (United States)

    Jovic, Vedran; Idriss, Hicham; Waterhouse, Geoffrey I. N.

    2016-11-01

    Here we describe the successful fabrication of six titania inverse opal (TiO2 IO) photocatalysts with fcc[1 1 1] pseudo photonic band gaps (PBGs) tuned to span the UV-vis region. Photocatalysts were fabricated by a colloidal crystal templating and sol-gel approach - a robust and highly applicable bottom-up scheme which allowed for precise control over the geometric and optical properties of the TiO2 IO photocatalysts. Optical properties of the TiO2 IO thin films were investigated in detail by UV-vis transmittance and reflectance measurements. The PBG along the fcc[1 1 1] direction in the TiO2 IOs was dependent on the inter-planar spacing in the [1 1 1] direction, the incident angle of light and the refractive index of the medium filling the macropores in the IOs, in agreement with a modified Bragg's law expression. Calculated photonic band structures for the photocatalysts revealed a PBG along the Γ → L direction at a/λ ∼ 0.74, in agreement with the experimental optical data. By coupling the low frequency edge of the PBG along the [1 1 1] direction with the electronic absorption edge of anatase TiO2, a two-fold enhancement in the rate of gas phase ethanol photo-oxidation in air was achieved. This enhancement appears to be associated with a 'slow photon' effect that acts to both enhance TiO2 absorption and inhibit spontaneous emission (i.e. suppress electron-hole pair recombination).

  3. Removal of high concentration CO2 from natural gas at elevated pressure via absorption process in packed column

    Institute of Scientific and Technical Information of China (English)

    L.S.Tan; K.K.Lau; M.A.Bustam; A.M.Shariff

    2012-01-01

    Carbon dioxide (CO2) removal is an essential step in natural gas (NG) processing to provide high quality gas stream products and minimize operational difficulties.This preliminary study aims to investigate the removal of CO2 at high concentration level from the mixture of CO2-NG gas stream at elevated pressure via absorption process.This is to explore the possibility of exploring high CO2 content natural gas reserves by treatment at offshore platform.A mixed amine solvent,Stonvent-Ⅱ,was used for the absorption of approximately 75 vol% CO2 in CO2-NG stream at a pressure of 10 barg.The initial solvent temperature was varied in order to study the impact of initial temperature on the absorption performance.Preliminary study at temperatures of 35 ℃ and 45 ℃ indicates that Stonvent-Ⅱ was able to perform almost 100% removal of CO2 under both conditions.However,the CO2 absorption effect took place faster when the initial liquid temperature was lower.This is because when the initial liquid temperature is high,the temperature increase in the packing bed caused by the reaction heat is high which impacts the efficiency of absorption negatively.

  4. CHARACTERISTIC OF SHALE GAS RESERVOIR USING LMR (LAMBDA-MU-RHO INVERSION: CASE STUDY BARNETT SHALE, FORT WORTH BASIN TEXAS, USA

    Directory of Open Access Journals (Sweden)

    Hagayudha Timotius

    2017-07-01

    Full Text Available The decreasing of fossil fuel reserves in the conventional reservoir has made geologists and geophysicists to explore alternative energy source that could answer energy needs in the future. Therefore the exploration of oil and gas that is still trapped in the source rock (shale is needed, and one of them still developed in shale gas. The method of Amplitude Versus Offset (AVO Inversion is used for Lambda-Mu-Rho attributes, that is expected to assess values of physical parameters of shale. Fort Worth Basin is chosen to be a study area because, the Barnett Shale Formation has proven contains of oil and gas. This study using synthetic seismic data, based on geological model and well log data obtained from Vermylen (2012. It is expected from the study of Barnett Shale that related to shale gas development could be applied.

  5. Influence of the gas-liquid flow configuration in the absorption column on photosynthetic biogas upgrading in algal-bacterial photobioreactors.

    Science.gov (United States)

    Toledo-Cervantes, Alma; Madrid-Chirinos, Cindy; Cantera, Sara; Lebrero, Raquel; Muñoz, Raúl

    2017-02-01

    The potential of an algal-bacterial system consisting of a high rate algal pond (HRAP) interconnected to an absorption column (AC) via recirculation of the cultivation broth for the upgrading of biogas and digestate was investigated. The influence of the gas-liquid flow configuration in the AC on the photosynthetic biogas upgrading process was assessed. AC operation in a co-current configuration enabled to maintain a biomass productivity of 15gm(-2)d(-1), while during counter-current operation biomass productivity decreased to 8.7±0.5gm(-2)d(-1) as a result of trace metal limitation. A bio-methane composition complying with most international regulatory limits for injection into natural gas grids was obtained regardless of the gas-liquid flow configuration. Furthermore, the influence of the recycling liquid to biogas flowrate (L/G) ratio on bio-methane quality was assessed under both operational configurations obtaining the best composition at an L/G ratio of 0.5 and co-current flow operation.

  6. Solution of an Inverse Problem of Heat Conduction of 45 Steel with Martensite Phase Transformation in High Pressure during Gas Quenching

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In order to simulate thermal strains, thermal stresses, residual stresses and microstructure of the steel during gas quenching by means of the numerical method, it is necessary to obtain an accurate boundary condition of temperature field. The surface heat transfer coefficient is a key parameter. The explicit finite difference method, nonlinear estimation method and the experimental relation between temperature and time during gas quenching have been used to solve the inverse problem of heat conduction. The relationship between surface temperature and surface heat transfer coefficient of a cylinder has been given. The nonlinear surface heat transfer coefficients include the coupled effects between martensitic phase transformation and temperature.

  7. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Akihiro [Scientific Investigation Laboratory, Hiroshima Prefectural Police Headquarters, Kohnan 2-26-3, Naka-ku, Hiroshima 730-0825 (Japan); Nishida, Manami [Hiroshima University Technical Center, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan); Saito, Takeshi [Department of Emergency and Critical Care Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara, Kanagawa 259-1143 (Japan); Kishiyama, Izumi; Miyazaki, Shota [GL Sciences Inc., Sayamagahara 237-2, Iruma, Saitama 358-0032 (Japan); Murakami, Katsunori [Scientific Investigation Laboratory, Hiroshima Prefectural Police Headquarters, Kohnan 2-26-3, Naka-ku, Hiroshima 730-0825 (Japan); Nagao, Masataka [Department of Forensic Medicine, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan); Namura, Akira, E-mail: namera@hiroshima-u.ac.jp [Department of Forensic Medicine, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan)

    2010-02-19

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d{sub 5} was used as an internal standard. The linear ranges were 0.01-5.0 {mu}g mL{sup -1} for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 {mu}g mL{sup -1} for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation {>=}0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 {mu}g mL{sup -1} of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio {>=} 3) in urine was 5 ng mL{sup -1} for MA and MDMA and 10 ng mL{sup -1} for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.

  8. Separating methane emissions from biogenic sources and natural gas by vertical column enhancements of ammonia, ethane, and methane in the Colorado Front Range

    Science.gov (United States)

    Chiu, R.; Volkamer, R. M.; Blumenstock, T.; Hase, F.; Hannigan, J. W.; Kille, N.; Frey, M.; Kumar Sha, M.; Orphal, J.

    2015-12-01

    Methane sources in the Colorado Front Range include biogenic sources from cattle feedlots and natural gas operations. Although numerous studies have measured methane emissions, there remains significant uncertainty regarding the relative contributions of these various methane emission sources. Here we present data from a March 2015 field campaign that deployed two Bruker EM27 Sun Fourier Transform Spectrometers (FTS) and the University of Colorado Solar Occultation Flux (CU-SOF) FTS in Eaton, Colorado; the former were used to measure enhancements in the methane vertical column densities (VCD), while the latter was used to measure ethane and ammonia VCDs. A third EM27 FTS was deployed to a background site in Westminster, Colorado which was far removed from cattle and petroleum operations. Northerly winds make possible the determination of methane VCD column enhancement from Westminster to Eaton. All instruments were compared during several background days at the National Center for Atmospheric Research (NCAR) in Boulder, Colorado. This presentation explores the potential of methane source attribution using ammonia as a tracer for feedlot emissions and ethane as a tracer for petroleum emissions.

  9. Quantitative extraction of methylgermanium species at trace levels and determination by on-column capillary gas chromatography with flame photometric detector

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    A solvent extraction procedure for the quantitativeextraction of trace levels of methylgermanium species as theirchloride complex has been developed and the extract was determinedby an on-column capillary gas chromatography with a lab-modifiedflame phorometric detector(FPD) using quartz surface-inducedgermanium emission after pentylation with Grignard reaction. Theextracted percentages for TMGe, DMGe and MMGe in a 100-ml 9mol/LHCl aqueous solution by a single extraction with 1 ml hexane are86.6%, 87.4% and 96.2%, respectively. The precision for overallprocedure range from 3.9% to 7.5%. The extraction was found to beindependent of the initial concentration of methylgermanium speciesin the aqueous phase, which typically varied from 0.1 to 10 μg. This method is suitable for most types of environmental samples and, are superior to all hydride generation coupled spectrometric andspectrophotometric methods in terms of selectivity and toleranceability to interference.

  10. Static headspace-multicapillary column with gas chromatography coupled to ion mobility spectrometry as a simple approach for the discrimination of crude and processed traditional Chinese medicines.

    Science.gov (United States)

    Cao, Gang; Shou, Qiyang; Li, Qinglin; Jiang, Jianping; Chen, Xiaocheng

    2014-11-01

    The processing procedure can alter the nature and chemical transformation of traditional Chinese medicine to accommodate different clinical dispensing and preparation requirements. In this study, static headspace-multicapillary column with gas chromatography coupled to ion mobility spectrometry was developed for the rapid and sensitive discrimination of crude and processed traditional Chinese medicine. Using Radix Paeoniae Alba as a traditional Chinese medicine model, the combined power of this approach was illustrated by classifying the crude and processed Radix Paeoniae Alba samples into two main categories. The contents of the main components in Radix Paeoniae Alba varied significantly. The established method could promote the use of ion mobility spectrometry in intrinsic quality control and differentiation of herbal medicines from other processed products or preparations.

  11. 鼓泡塔中水合物法分离混合气体的数值模拟%Numerical Simulation of Separating Gas Mixtures via Hydrate Formation in Bubble Column

    Institute of Scientific and Technical Information of China (English)

    罗艳托; 朱建华; 陈光进

    2007-01-01

    To develop a new technique for separating gas mixtures via hydrate formation, a set of medium-sized experimental bubble column reactor equipment was constructed.On the basis of the structure parameters of the experimental bubble column reactor, assuming that the liquid phase was in the axial dispersion regime and the gas phase was in the plug flow regime, in the presence of hydrate promoter tetrahydrofuran (THF), the rate of hydrogen enrichment for CH4+H2 gas mixtures at different operational conditions (such as temperature, pressure, concentration of gas components, gas flow rate, liquid flow rate) were simulated.The heat product of the hydrate reaction and its axial distribution under different operational conditions were also calculated.The results would be helpful not only to setting and optimizing operation conditions and design of multi-refrigeration equipment, but also to hydrate separation technique industrialization.

  12. Transverse ionization instability of the elongated dust cloud in the gas discharge uniform positive column under microgravity conditions

    Science.gov (United States)

    Zobnin, A. V.; Usachev, A. D.; Lipaev, A. M.; Petrov, O. F.; Fortov, V. E.; Pustylnik, M. Yu; Thomas, H. M.; Fink, M. A.; Thoma, M. H.; Padalka, G. I.

    2016-11-01

    A new kind of dusty plasma instability was observed in the joint Russian-European “Plasma Kristall-4” space experiment on board of the International Space Station. An elongated cylindrical dust particle cloud of 0.9 cm diameter with a length of 20 cm was formed in the uniform positive column of a dc discharge operating in a polarity switching mode (dc/ps-mode). The discharge was operated in a glass tube of 3 cm inner diameter with a total length of 85 cm filled by argon at a pressure of 0.5 mbar. The dc/ps discharge was operated at 1 mA with a polarity switching frequency of 500 Hz. During the experiment, all the dust particles vibrated synchronized in the same phase in the direction perpendicular to the tube axis with a frequency of 24 Hz and peak-to-peak amplitude of 0.2 mm. The vibration was attended by discharge glow fluctuation. The nature of the cloud vibration is discussed.

  13. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chlorinated pesticides in aquatic tissue by capillary-column gas chromatography with electron-capture detection

    Science.gov (United States)

    Leiker, Thomas J.; Madsen, J.E.; Deacon, J.R.; Foreman, W.T.

    1995-01-01

    A method for the determination of chlorinated organic compounds in aquatic tissue by dual capillary-column gas chromatography with electron-capture detection is described. Whole-body-fish or corbicula tissue is homogenized, Soxhlet extracted, lipid removed by gel permeation chromatography, and fractionated using alumina/silica adsorption chromatography. The extracts are analyzed by dissimilar capillary-column gas chromatography with electron-capture detection. The method reporting limits are 5 micrograms per kilogram (μg/kg) for chlorinated compounds, 50 μg/kg for polychlorinated biphenyls, and 200 μg/kg for toxaphene.

  14. Probing the Reaction Intermediates for the Water-Gas Shift over Inverse CeOx/Au(111) Catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, J.A.; Senanayake, S.D.; Stacchiola, D.; Evans, J.; Estrella, M.; Barrio-Pliego, L.; Pérez, M.; Hrbek, J.

    2010-05-04

    The water-gas shift (WGS) is an important reaction for the production of molecular H{sub 2} from CO and H{sub 2}O. An inverse CeO{sub x}/Au(1 1 1) catalyst exhibits a very good WGS activity, better than that of copper surfaces or Cu nanoparticles dispersed on a ZnO(0 0 0 {bar 1}) substrate which model current WGS industrial catalysts. In this work we report on intermediates likely to arise during the CO + H{sub 2}O reaction over CeO{sub x}/Au(1 1 1) using soft X-ray photoemission (sXPS) and near-edge X-ray absorption fine structure (NEXAFS). Several potential intermediates including formates (HCOO), carbonates (CO{sub 3}) and carboxylates (HOCO) are considered. Adsorption of HCOOH and CO{sub 2} is used to create both HCOO and CO{sub 3} on the CeO{sub x}/Au(1 1 1) surface, respectively. HCOO appears to have greater stability with desorption temperatures up to 600 K while CO{sub 3} only survives on the surface up to 300 K. On the CeO{sub x}/Au(1 1 1) catalysts, the presence of Ce{sup 3+} leads to the dissociation of H{sub 2}O to give OH groups. We demonstrate experimentally that the OH species are stable on the surface up to 600 K and interact with CO to yield weakly bound intermediates. When there is an abundance of Ce{sup 4+}, the OH concentration is diminished and the likely intermediates are carbonates. As the surface defects are increased and the Ce{sup 3+}/Ce{sup 4+} ratio grows, the OH concentration also grows and both carbonate and formate species are observed on the surface after dosing CO to H{sub 2}O/CeO{sub x}/Au(1 1 1). The addition of ceria nanoparticles to Au(1 1 1) is essential to generate an active WGS catalyst and to increase the production and stability of key reaction intermediates (OH, HCOO and CO{sub 3}).

  15. Probing the Reaction Intermediates for the Water–gas Shift over Inverse CeOx / Au(1 1 1) Catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Senanayake, S.; Stacchiola, D; Evans, J; Estrella, M; Barrio, L; Perez, M; Hrbek, J; Rodriguez, J

    2010-01-01

    The water-gas shift (WGS) is an important reaction for the production of molecular H{sub 2} from CO and H{sub 2}O. An inverse CeO{sub x}/Au(1 1 1) catalyst exhibits a very good WGS activity, better than that of copper surfaces or Cu nanoparticles dispersed on a ZnO(0 0 0 {bar 1}) substrate which model current WGS industrial catalysts. In this work we report on intermediates likely to arise during the CO + H{sub 2}O reaction over CeO{sub x}/Au(1 1 1) using soft X-ray photoemission (sXPS) and near-edge X-ray absorption fine structure (NEXAFS). Several potential intermediates including formates (HCOO), carbonates (CO{sub 3}) and carboxylates (HOCO) are considered. Adsorption of HCOOH and CO{sub 2} is used to create both HCOO and CO{sub 3} on the CeO{sub x}/Au(1 1 1) surface, respectively. HCOO appears to have greater stability with desorption temperatures up to 600 K while CO{sub 3} only survives on the surface up to 300 K. On the CeO{sub x}/Au(1 1 1) catalysts, the presence of Ce{sup 3+} leads to the dissociation of H{sub 2}O to give OH groups. We demonstrate experimentally that the OH species are stable on the surface up to 600 K and interact with CO to yield weakly bound intermediates. When there is an abundance of Ce{sup 4+}, the OH concentration is diminished and the likely intermediates are carbonates. As the surface defects are increased and the Ce{sup 3+}/Ce{sup 4+} ratio grows, the OH concentration also grows and both carbonate and formate species are observed on the surface after dosing CO to H{sub 2}O/CeO{sub x}/Au(1 1 1). The addition of ceria nanoparticles to Au(1 1 1) is essential to generate an active WGS catalyst and to increase the production and stability of key reaction intermediates (OH, HCOO and CO{sub 3}).

  16. Reading Columns

    OpenAIRE

    Coutts, Marion

    2008-01-01

    Reading Columns are twin permanent public sculptures commissioned as part of a £245m scheme for the redevelopment of the Chatham Place area in Reading. Dimensions: 3.5m high x 1.3m diameter each Field of knowledge: The work consists of twin bespoke columns of stainless steel and glass over digital colour transparencies. The piece revisits and reworks the idea of the Morris Column, a 19th C feature characteristic of major European metropolitan centres. A wraparound image on each of ...

  17. [Quantification of acrylamide in foods by gas chromatography-mass spectrometry coupled with pro-column derivatization].

    Science.gov (United States)

    Yang, Sichao; Zhang, Hui; Wang, Junhan; Chen, Fang

    2011-05-01

    The quantification of acrylamide in foods was investigated by gas chromatography-mass spectrometry (GC-MS). In this method, (13)C3-acrylamide was used as an internal standard. The samples were homogenized, defatted with hexane and extracted with ethyl acetate for twice. The derivatization of acrylamide into 2-bromopropenamide (2-BPA) was done using potassium bromide/potassium bromate at 4 degrees C for 90 min. Selective ion monitoring mode was chosen to monitor objective chromatography. This method had a good linearity between 0.05-2.00 mg/kg (r2 = 0.9995), and the limits of detection and quantification were 3 microg/kg and 7 microg/kg, respectively. The recoveries of acrylamide were in the range of 62.7%-65.5%. In order to confirm this GC-MS method, the acrylamide in foods was also determined by high performance liquid chromatography coupled to quadrupole tandem mass spectrometry (HPLC-MS/MS), which had been proved in our laboratory. The concentrations of acrylamide in the samples quantified by GC-MS were slightly higher than those detected by HPLC-MS/MS. This method can be used to quantify acrylamide in normal foods.

  18. A Laboratory Experiment To Measure Henry's Law Constants of Volatile Organic Compounds with a Bubble Column and a Gas Chromatography Flame Ionization Detector (GC-FID)

    Science.gov (United States)

    Lee, Shan-Hu; Mukherjee, Souptik; Brewer, Brittany; Ryan, Raphael; Yu, Huan; Gangoda, Mahinda

    2013-01-01

    An undergraduate laboratory experiment is described to measure Henry's law constants of organic compounds using a bubble column and gas chromatography flame ionization detector (GC-FID). This experiment is designed for upper-division undergraduate laboratory courses and can be implemented in conjunction with physical chemistry, analytical…

  19. A Laboratory Experiment To Measure Henry's Law Constants of Volatile Organic Compounds with a Bubble Column and a Gas Chromatography Flame Ionization Detector (GC-FID)

    Science.gov (United States)

    Lee, Shan-Hu; Mukherjee, Souptik; Brewer, Brittany; Ryan, Raphael; Yu, Huan; Gangoda, Mahinda

    2013-01-01

    An undergraduate laboratory experiment is described to measure Henry's law constants of organic compounds using a bubble column and gas chromatography flame ionization detector (GC-FID). This experiment is designed for upper-division undergraduate laboratory courses and can be implemented in conjunction with physical chemistry, analytical…

  20. Analysis of polycyclic aromatic hydrocarbons I. Determination by gas chromatography with glass and fused silica capillary columns; Analisis de Hidrocarburos aromaticos policiclicos. I. Determinacion por cromatografia de gases con columnas capilares de vidrio de silice fundida

    Energy Technology Data Exchange (ETDEWEB)

    Perez, M. M.; Gonzalez, D.

    1987-07-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silica capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (Author) 17 refs.

  1. 高瓦斯矿井瓦排巷墩柱式支护技术研究%Research on pier column supporting technology for gas discharge laneway of high gas mine

    Institute of Scientific and Technical Information of China (English)

    史红邈

    2016-01-01

    高瓦斯矿井综采工作面的瓦排巷二次支护采用木垛支护,存在承载力低、巷道变形严重、通风效果差等一系列问题,针对这些问题提出采用聚苯乙烯泡沫(EPS)混凝土墩柱式巷道支护技术,并在余吾煤业 N2202工作面的外错瓦排巷进行了工业现场试验。结果表明采用墩柱式支护的巷道顶底板移近量较小,巷道围岩变形小,支护效果明显强于木垛支护;墩柱式支护具有重量轻、承载力大、抗压强度大的特性,且其耐久性和耐燃性都强于木垛支护。介绍了墩柱的结构、材料、抗压性能及应用效果。%Currently,wood cribs were used for the secondary support of gas discharge lanew-ay in fully mechanized working face of high gas mine,but their bearing capacity was low,the roadway deformation was serious and the ventilation effect was bad��Aiming at these problems, the roadway supporting technology of concrete pier with expandable polystyrene foam was put forward,and the industrial field test was carried out in outward located gas discharge laneway of N2202 working face of Yuwu Coal Mine��The results showed that the displacement between roof and floor in pier column supporting roadway was less,the surrounding rock deformation was lit-tle,and the supporting effect was obviously better than wood crib supporting��The pier column supporting method had light weight,large bearing capacity and big compressive strength,and its durability and flame resistance were stronger than wood crib supporting��Besides,the structure, compressive property and application effects of pier column were introduced.

  2. 实际气体分子间吸引相互作用对转换温度的影响%The Effect about Attractive Interaction among the Actual Gas Molecules to Inversion Temperature

    Institute of Scientific and Technical Information of China (English)

    张永梅

    2015-01-01

    讨论了实际气体分子间吸引相互作用对焦耳汤姆孙效应转换温度和转换曲线的影响,并与 CO 2气体的实验值进行了比较。%Considering the effect of attractive interaction between the actual gas molecules , the inversion temperature and inversion curve of Joule Thomson effect were discussed theoretically .In the mean time ,the experimental values of inversion temperatures of CO 2 actual gas were compared with theoretical values .

  3. Retrieval of sea surface temperature and trace gas column averaged from GOSAT, IASI-A, and IASI-B over the Arctic Ocean in summer 2010 and 2013

    Science.gov (United States)

    Payan, Sébastien; Camy-Peyret, Claude; Bureau, Jérôme

    2016-04-01

    The Arctic Ocean is a very important region of the globe in which the effect of climate change can be detected over short time periods. We have used the possibility provided by the three infrared sounders TANSO-FTS on the GOSAT platform, IASI-A, and IASI-B on the MetOp platforms to retrieve the sea surface temperature (Tsurf) and the column averaged mixing ratio of several trace gases (CO2, CH4, N2O, O3) for pairs of nearly coinciding footprints (IFOVs) at small time separations (typically for IASI 46 min and 54 min depending on which satellite has first observed the corresponding scene). A strict filtering based on the AVHRR cloud fraction and the radiance analysis within the GOSAT and IASI footprints lead to a large number of quasi-coinciding IFOVs for which a 1D-var inversion (Tsurf and XCO2 as the main parameters in the state vector, plus scaling factors for the profiles of H2O and O3) has been performed. As an example, we used during retrieval the atmospheric window between 940 and 980 cm-1 (CO2 laser band) for which the sensitivity to the surface is maximum. The statistics of the comparison between IASI-A and IASI-B retrievals is presented and compared to the corresponding Eumetsat L2 products. The months of July and August for the years 2010 and 2013 have been considered since in these Arctic summer conditions the ice pack coverage is reduced. The differences between these two consecutive years is discussed and a comparison with 2010 (for which only IASI-A was in orbit) is confirming that IASI can indeed be used for climate change studies.

  4. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  5. Gas/slurry flow in coal-liquefaction processes (fluid dynamics in a three-phase-flow column). Final technical progress report, 1 October 1979-31 March 1982

    Energy Technology Data Exchange (ETDEWEB)

    Ying, D.H.S.; Sivasubramanian, R.; Moujaes, S.F.; Givens, E.N.

    1982-04-01

    A commercial coal liquefaction plant will employ vertical tubular reactors feeding slurry and gas concurrently upward through these vessels. In the SRC-I plant design the reactor is essentially an empty vessel with only a distributor plate located near the inlet. Because the commercial plant represents a considerable scale-up over Wilsonville or any pilot plant, this program addressed the need for additional data on behavior of three phase systems in large vessels. Parameters that were investigated in this program were studied at conditions that relate directly to projected plant operating conditions. The fluid dynamic behavior of the three-phase upflow system was studied by measuring gas and slurry holdup, liquid dispersion, solids suspension and solids accumulation. The dependent parameters are gas and liquid velocities, solid particle size, solids concentration, liquid viscosity, liquid surface tension and inlet distributor. Within the range of liquid superficial velocity from 0.0 to 0.5 ft/sec, gas holdup is found to be independent of liquid flow which agrees with other investigators. The results also confirm our previous finding that gas holdup is independent of column diameter when the column diameter is 5 inches or larger. The gas holdup depends strongly on gas flow rate; gas holdup increases with increasing gas velocity. The effect of solids particles on gas holdup depends on the gas flow rate. Increasing liquid viscosity and surface tension reduce gas holdup which agrees with other investigators. Because of the complexity of the system, we could not find a single correlation to best fit all the data. The degree of liquid backmixing markedly affects chemical changes occurring in the dissolver, such as sulfur removal, and oil and distillate formation.

  6. Analysis of alkyl phosphates in petroleum samples by comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection and post-column Deans switching.

    Science.gov (United States)

    Nizio, Katie D; Harynuk, James J

    2012-08-24

    Alkyl phosphate based gellants used as viscosity builders for fracturing fluids used in the process of hydraulic fracturing have been implicated in numerous refinery-fouling incidents in North America. In response, industry developed an inductively coupled plasma optical emission spectroscopy (ICP-OES) based method for the analysis of total volatile phosphorus in distillate fractions of crude oil; however, this method is plagued by poor precision and a high limit of detection (0.5±1μg phosphorus mL(-1)). Furthermore this method cannot provide speciation information, which is critical for developing an understanding of the challenge of alkyl phosphates at a molecular level. An approach using comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection (GC×GC-NPD) and post-column Deans switching is presented. This method provides qualitative and quantitative profiles of alkyl phosphates in industrial petroleum samples with increased precision and at levels comparable to or below those achievable by ICP-OES. A recovery study in a fracturing fluid sample and a profiling study of alkyl phosphates in four recovered fracturing fluid/crude oil mixtures (flowback) are also presented.

  7. Determination of Wastewater Compounds in Whole Water by Continuous Liquid-Liquid Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.

    2006-01-01

    A method for the determination of 69 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals on aquatic organisms in wastewater. This method also is useful for evaluating the effects of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are indicators of wastewater or have endocrine-disrupting potential. These compounds include the alkylphenol ethoxylate nonionic surfactants, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Wastewater compounds in whole-water samples were extracted using continuous liquid-liquid extractors and methylene chloride solvent, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 0.5 microgram per liter averaged 72 percent ? 8 percent relative standard deviation. The concentration of 21 compounds is always reported as estimated because method recovery was less than 60 percent, variability was greater than 25 percent relative standard deviation, or standard reference compounds were prepared from technical mixtures. Initial method detection limits averaged 0.18 microgram per liter. Samples were preserved by adding 60 grams of sodium chloride and stored at 4 degrees Celsius. The laboratory established a sample holding-time limit prior to sample extraction of 14 days from the date of collection.

  8. Sequential extraction of inorganic arsenic compounds and methyl arsenate in human urine using mixed-mode monolithic silica spin column coupled with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Namera, Akira; Takeuchi, Akito; Saito, Takeshi; Miyazaki, Shota; Oikawa, Hiroshi; Saruwatari, Tatsuro; Nagao, Masataka

    2012-09-01

    A sequential analytical method was developed for the detection of arsenite, arsenate, and methylarsenate in human urine by gas chromatography-mass spectrometry (GC-MS). The combination of a derivatization of trivalent arsenic compounds by 2,3-dithio-1-propanol (British antilewisite; BAL) and a reduction of pentavalent arsenic compounds (arsenate and methylarsenate) were accomplished to carry out the analysis of arsenic compounds in urine. The arsenic derivatives obtained using BAL were extracted in a stepwise manner using a monolithic spin column and analyzed by GC-MS. A linear curve was observed for concentrations of arsenic compounds of 2.0 to 200 ng/mL, where the correlation coefficients of calibration curves were greater than 0.996 (for a signal-to-noise (S/N) ratio >10). The detection limits were 1 ng/mL (S/N > 3). Recoveries of the targets in urine were in the range 91.9-106.5%, and RSDs of the intra- and interday assay for urine samples containing 5, 50, and 150 ng/mL of arsenic compounds varied between 2.95 and 13.4%. The results from real samples obtained from a patient suspected of having ingested As containing medications using this proposed method were in good agreement with those obtained using high-performance liquid chromatography with inductively coupled plasma mass spectrometry.

  9. Simultaneous determination of 3-monochloropropane-1,2-diol and acrylamide in food by gas chromatography-triple quadrupole mass spectrometry with coupled column separation.

    Science.gov (United States)

    Xu, Xiao-min; He, Hua-li; Zhu, Yan; Feng, Liang; Ying, Ying; Huang, Bai-fen; Shen, Hai-tao; Han, Jian-long; Ren, Yi-ping

    2013-01-14

    Both 3-monochloropropane-1,2-diol (3-MCPD) and acrylamide are contaminants found in heat-processed foods and their related products. A quantitative method was developed for the simultaneous determination of both contaminants in food by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). The analytes were purified and extracted by the matrix solid-phase dispersion extraction (MSPDE) technique with Extrelut NT. A coupled column (a 3 m Innowax combined with a 30 m DB-5 ms) was developed to separate both compounds efficiently without derivatization. Triple quadrupole mass spectrometry in multiple reaction monitoring mode (MRM) was applied to suppress matrix interference and obtain good sensitivity in the determination of both analytes. The limit of detection (LOD) in the sample matrix was 5 μg kg(-1) for 3-MCPD or acrylamide. The average recoveries for 3-MCPD and acrylamide in different food matrices were 90.5-107% and 81.9-95.7%, respectively, with the intraday relative standard deviations (RSDs) of 5.6-13.5% and 5.3-13.4%, respectively. The interday RSDs were 6.1-12.6% for 3-MCPD and were 5.0-12.8% for acrylamide. Both contaminants were found in samples of bread, fried chips, fried instant noodles, soy sauce, and instant noodle flavoring. Neither 3-MCPD nor acrylamide was detected in the samples of dairy products (solid or liquid samples) and non-fried instant noodles. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by C-18 solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    Science.gov (United States)

    Zaugg, Steven D.; Sandstrom, Mark W.; Smith, Steven G.; Fehlberg, Kevin M.

    1995-01-01

    A method for the isolation of 41 pesticides and pesticide metabolites in natural-water samples using C-18 solid-phase extraction and determination by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction columns containing octadecyl-bonded porous silica to extract the pesticides. The columns are dried using carbon dioxide or nitrogen gas, and adsorbed pesticides are removed from the columns by elution with 3.0 milliliters of hexane-isopropanol (3:1). Extracted pesticides are determined by capillary- column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 4 micrograms per liter (g/L) for most pesticides, with the exception of widely used corn herbicides--atrazine, alachlor, cyanazine, and metolachlor--which have upper concentration limits of 20 g/L. Single- operator method detection limits in reagent-water samples range from 0.001 to 0.018 g/L. Average short-term single-operator precision in reagent- water samples is 7 percent at the 0.1- and 1.0-g/L levels and 8 percent at the 0.01-g/L level. Mean recoveries in reagent-water samples are 73 percent at the 0.1- and 1.0-g/L levels and 83 percent at the 0.01-g/L level. The estimated holding time for pesticides after extraction on the solid-phase extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time.

  11. Column: lef

    NARCIS (Netherlands)

    Reep, Frans van der

    2012-01-01

    1e alinea column: Ook in je beleggingsbeslissingen is het voor echte performance wellicht tijd om eens voorbij best practices (dan word je namelijk hoogstens tweede) te kijken naar next practices. Als je op zeker speelt, verdien je weinig geld. Want anderen gingen je al voor. Maar kun je nog meer op

  12. Comprehensive theoretical studies on the gas phase SN2 reactions of anionic nucleophiles toward chloroamine and N-chlorodimethylamine with inversion and retention mechanisms.

    Science.gov (United States)

    Ren, Yi; Geng, Song; Wei, Xi-Guang; Wong, Ning-Bew; Li, Wai-Kee

    2011-12-01

    The anionic S(N)2 reactions at neutral nitrogen, Nu(-) + NR(2)Cl → NR(2)Nu + Cl(-) (R = H, Me; Nu = F, Cl, Br, OH, SH, SeH, NH(2), PH(2), AsH(2)) have been systematically studied computationally at the modified G2(+) level. Two reaction mechanisms, inversion and retention of configuration, have been investigated. The main purposes of this work are to explore the reactivity trend of anions toward NR(2)Cl (R = H, Me), the steric effect on the potential energy surfaces, and the leaving ability of the anion in S(N)2@N reactions. Our calculations indicate that the complexation energies are determined by the gas basicity (GB) of the nucleophile and the electronegativity (EN) of the attacking atom, and the overall reaction barrier in the inversion pathway is basically controlled by the GB value of the nucleophile. The retention pathway in the reactions of NR(2)Cl with Nu(-) (Nu = F, Cl, Br, OH, SH, SeH) is energetically unfavorable due to the barriers being larger than those in the inversion pathway by more than 120 kJ mol(-1). Activation strain model analyses show that a higher deformation energy and a weaker interaction between deformed reactants lead to higher overall barriers in the reactions of NMe(2)Cl than those in the reactions of NH(2)Cl. Our studies on the reverse process of the title reactions suggest that the leaving ability of the anion in the gas phase anionic S(N)2@N reactions is mainly determined by the strength of the N-LG bond, which is related to the negative hyperconjugation inherent in NR(2)Nu (R = H, Me; Nu = HO, HS, HSe, NH(2), PH(2), AsH(2)).

  13. Determination of Wastewater Compounds in Sediment and Soil by Pressurized Solvent Extraction, Solid-Phase Extraction, and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Burkhardt, Mark R.; Zaugg, Steven D.; Smith, Steven G.; ReVello, Rhiannon C.

    2006-01-01

    A method for the determination of 61 compounds in environmental sediment and soil samples is described. The method was developed in response to increasing concern over the effects of endocrine-disrupting chemicals in wastewater and wastewater-impacted sediment on aquatic organisms. This method also may be used to evaluate the effects of combined sanitary and storm-sewer overflow on the water and sediment quality of urban streams. Method development focused on the determination of compounds that were chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Sediment and soil samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from interfering matrix components by high-pressure water/isopropyl alcohol extraction. The compounds were isolated using disposable solid-phase extraction (SPE) cartridges containing chemically modified polystyrene-divinylbenzene resin. The cartridges were dried with nitrogen gas, and then sorbed compounds were eluted with methylene chloride (80 percent)-diethyl ether (20 percent) through Florisil/sodium sulfate SPE cartridge, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-sand samples fortified at 4 to 72 micrograms averaged 76 percent ?13 percent relative standard deviation for all method compounds. Initial method reporting levels for single-component compounds ranged from 50 to 500 micrograms per kilogram. The concentrations of 20 out of 61 compounds initially will be reported as estimated with the 'E' remark code for one of three reasons: (1) unacceptably low-biased recovery (less than 60 percent) or highly variable method performance

  14. Inverse Gas Chromatographic Study of the Oxidation Stability of Lubricating Base Oils via Solubility Parameter Calculations%采用反相气相色谱法通过计算溶解度参数考察润滑油的氧化稳定性

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The Flory-Huggins interaction parameter (χ∞1,2) and solubility parameter (δ2) and its hydrogen bonding sensing component (δh) were determined using inverse gas chromatography (IGC). These parameters were successfully used in the probes of chemical changes that occur during the oxidation of naphthenic and paraffinic base oils in a GC column. Changes in χ∞1,2 values reflect the different types of intermolecular interactions ( dispersive, polar, hydrogen bonding) of the given lubricating base oil during oxidation. The obtained results showed that δh component of solubility parameter is the most important parameter for probing the oxidativechemical changes during the oxidation of given lubricating oils.

  15. 出口压减压下非极性薄涂气相色谱柱的特性及应用%Performance and Application of Decompression and Low Coated Non-polar Liquid Phases in Gas Chromatographic Column

    Institute of Scientific and Technical Information of China (English)

    袁晓燕; 陈贻文

    2001-01-01

    In this paper,performance of decompression and low coated gas chromatographic column of non-polar liquid phases is described. Chromatographic parameters of a column packed with 0.5% OV-101 on glazing support (φ0.18~0.25mm) 302 was studied for C、C7、C8、C9 n-alkanes samples. The results showed that the column pressure 0.068 MPa was best,the column temperature for n-octane could be decreased to 52°C,column efficiency was four time as high as ordinary pressure detection.%以甲基硅油0V-101、210为固定液,研究了出口压减压下薄涂气相色谱柱的特性,从柱压、柱温、保留值、柱效、柱的稳定性等方面进行了探讨。应用于烷烃及几种农药的分离,效果良好。

  16. 高效填料塔中用柠檬酸/柠檬酸钠溶液 进行烟气脱硫的研究%Flue Gas Desulfurization by Citrate Solution in Packing Columns

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    以柠檬酸/柠檬酸钠溶液为缓冲液在高效规整填料塔中进行烟气脱硫。模拟的烟气首先在吸收塔中用柠檬酸钠溶液脱硫,然后富液在解吸塔中释放出SO2,再生的缓冲液返回吸收塔循环使用。研究了影响吸收及解吸效率的各种重要参数,确定了最佳操作条件。对解决SO2污染问题提供了应用基础。%FGD process using citric acid / sodium citrate buffer solution has been carried out in structured packing columns.SO2 in analog flue gas was first absorbed in aqueous sodium citrate solution in an absorption column and then recovered from the loaded solution in a desorption column.The regenerative buffer solution circulated to absorption column again for use.Several important factors that may affect SO2 absorption and desorption efficiency were tested individually.The optimal operating conditions for sodium citrate FGD process in pilot packing columns were determined,which can be extended into largescale FGD design.

  17. Oil- water separation efficiency in a gas- liquid cross- flow multi- stage flotation column%气-液错流式多级浮选塔内油水分离效率

    Institute of Scientific and Technical Information of China (English)

    严超宇; 刘艳升; 曹睿; 孙曙光

    2011-01-01

    以空气-含柴油污水为实验介质,在2级错流浮选塔中,考察了表观气速、液体流量和含油质量浓度对分离效率的影响.结果表明,总分离效率随表观气速的增大呈先增后降的变化趋势;液体流量的增大会显著降低浮选塔的总分离效率;污水含油质量浓度的提高会增大浮选塔的总分离效率.在液体流量为80 L/h,表观气速为3.75×10-3m/s的条件下,总分离效率较第1级提高了53.03%.%The effects of superficial gas velocity, liquid flux and oil mass concentration on the oil -water separation efficiency were investigated in a two - stage cross - flow flotation column with the air - diesel oil containing wastewater as experimental medium. The results showed that the oil removal efficiency increased with increasing the superficial gas velocity, then decreased when the superficial gas velocity approached to a certain value. The increases of liquid flux could significantly decrease the overall separation efficiency of the flotation column. The in-crement of oil mass concentration in the wastewater increased the overall separation efficiency. Under the condition of liquid flux 80 L/h and superficial gas velocity 3.75 x 10~3m/s,the overall separation efficiency for the two - stage flotation column was enhanced over 53.03% than that of the single - stage flotation column.

  18. 反相气相色谱法表征HDPE的表面性质%Characterization of surface properties of high density polyethylene by inverse gas chromatography

    Institute of Scientific and Technical Information of China (English)

    田华; 张正方; 刘睿婷; 唐军; 王强

    2011-01-01

    采用反相气相色谱技术,分别测定不同分子探针在不同温度下通过高密度聚乙烯(H DPE)的保留时间,计算HDPE表面色散自由能与表面Lewis酸碱常数.HDPE表面色散自由能随温度的升高呈线性降低,且为弱碱性的Lewis两性聚合物材料.%The retention time of different molecular probes through high-density polyethylene(HDPE) were determined by inverse gas chromatography technology at different temperatures. The surface free energy and Lewis number of HDPE were figured out. The surface free energy decreased linearly with the increase in temperature, and HDPE was an alkalescent Lewis amphoteric polymer.

  19. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  20. Pre-drill Pore pressure estimation in shale gas reservoirs using seismic genetic inversion: Application to Barnett shale.

    Science.gov (United States)

    Ouadfeul, Sid-Ali; Aliouane, Leila; Eladj, Said

    2017-04-01

    In this paper, the seismic genetic inversion is used for estimation of the pore pressure before drilling, the first stage is to invert the 3D seismic cube recorded in the Fot Worth basin located in the United States of America using the artificial neural network. The Multilayer Perceptron neural network is trained in a supervised mode using the stacked 3D seismic amplitudes near three wells as an input and the calculated acoustic impedances derived from the density and sonic logs recorded in these wells as an output. During the training the weights of connections between neurons are optimized, then the whole seismic cube is propagated though the neural machine. The output of this machine is the cube of the acoustic impedance. A linear relationship between the depth and velocity are derived using sonic well-log data of a vertical well, this relationship will be us ed as a vertical trend in the Eaton's model. The acoustic impedances are used to deduce the pore pressure from the Eaton's model. The proposed process is applied to derive the pore pressure in the Lower Barnett shale, obtained results can be used for well-bore stability and hydraulic fracture planning and simulation.

  1. Study of 20O via the (d,p) reaction in inverse kinematics employing the active gas target detector ANASEN

    Science.gov (United States)

    Santiago-Gonzalez, D.; Wiedenhöver, I.; Baby, L. T.; Koshchiy, E.; Rogachev, G. V.; Blackmon, J. C.; Linhardt, L. E.

    2013-10-01

    The energetic location of the d3/2-orbital in neutron-rich nuclei is of particular interest as it determines the location of the drip-line in the oxygen isotopes. Its behavior has recently been described as a consequence of three-body forces. Manifestations of such forces are traced through the location of the d3/2 orbital, which closer to stability leads to highly excited states. In order to study the location and fragmentation of this orbital in 20O a beam of the short-lived 19O was produced at the RESOLUT radioactive beam facility of the Florida State University with an intensity of 1 ×105 pps, 65 % purity and 4.11 MeV/u. The chamber of the active gas target detector ANASEN was filled with molecular deuterium gas (D2) which yielded 20O via the 19O (d , p) reaction. The ejected protons were measured with large solid angle coverage and for beam energies between 2.9 and 3.7 MeV/u. Data from the 17O(d , p) 18O reaction was acquired to verify our experimental methods and analysis techniques. We will present the latest advances in the analysis of the 19O(d , p) 20O data and demonstrate the capabilities of ANASEN. Work supported by the National Science Foundation.

  2. Direct and inverse neural networks modelling applied to study the influence of the gas diffusion layer properties on PBI-based PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Lobato, Justo; Canizares, Pablo; Rodrigo, Manuel A.; Linares, Jose J. [Chemical Engineering Department, University of Castilla-La Mancha, Campus Universitario s/n, 13004 Ciudad Real (Spain); Piuleac, Ciprian-George; Curteanu, Silvia [Faculty of Chemical Engineering and Environmental Protection, Department of Chemical Engineering, ' ' Gh. Asachi' ' Technical University Iasi Bd. D. Mangeron, No. 71A, 700050 IASI (Romania)

    2010-08-15

    This article shows the application of a very useful mathematical tool, artificial neural networks, to predict the fuel cells results (the value of the tortuosity and the cell voltage, at a given current density, and therefore, the power) on the basis of several properties that define a Gas Diffusion Layer: Teflon content, air permeability, porosity, mean pore size, hydrophobia level. Four neural networks types (multilayer perceptron, generalized feedforward network, modular neural network, and Jordan-Elman neural network) have been applied, with a good fitting between the predicted and the experimental values in the polarization curves. A simple feedforward neural network with one hidden layer proved to be an accurate model with good generalization capability (error about 1% in the validation phase). A procedure based on inverse neural network modelling was able to determine, with small errors, the initial conditions leading to imposed values for characteristics of the fuel cell. In addition, the use of this tool has been proved to be very attractive in order to predict the cell performance, and more interestingly, the influence of the properties of the gas diffusion layer on the cell performance, allowing possible enhancements of this material by changing some of its properties. (author)

  3. 工业浮选柱的气含率测定及其影响因素研究%Measurement of gas holdup of industrial flotation columns and study on influential factors

    Institute of Scientific and Technical Information of China (English)

    岳双凌; 刘炯天; 廖寅飞

    2012-01-01

    The gas holdup is one of the important parameters that affect separation efficiency of the flotation column.The pressure difference method was used to measure the gas holdup inside the flotation column,and a system of measuring the gas holdup of the industrial flotation column was designed based on direct digital control(DDC) technology and MCGS configuration software.The influences of circulating pressure,air flow and frother dosage on the gas holdup of the industrial flotation column were studied by single-factor test.The results showed that the circulating pressure,air flow and frother dosage significantly affected the gas holdup.Within a certain range,the gas holdup increased along with the increase in the circulating pressure,air flow and frother dosage,while reaching a certain extent,the increase rate gradually decreased.%气含率是影响浮选柱分选效果的重要参数之一。采用压差法测定浮选柱内部的气含率,并基于直接数字控制(DDC)技术和MCGS组态软件,设计开发了适合于工业浮选柱的气含率测试系统。通过对循环压力、充气量和起泡剂用量3个因素进行试验,研究了它们对工业浮选柱气含率的影响。结果表明:循环压力、充气量和起泡剂用量对气含率影响显著;在一定范围内气含率随着循环压力、充气量和起泡剂用量增大而增大,当增大到一定程度时气含率增大的幅度逐渐减小。

  4. Column: Every Last Byte

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-06-01

    Full Text Available Inheritance powder is the name that was given to poisons, especially arsenic, that were commonly used in the 17th and early 18th centuries to hasten the death of the elderly. For most of the 17th century, arsenic was deadly but undetectable, making it nearly impossible to prove that someone had been poisoned. The first arsenic test produced a gas—hardly something that a scientist could show to a judge. Faced with a growing epidemic of poisonings, doctors and chemists spent decades searching for something better.(see PDF for full column

  5. 基于BP神经网络的旋流-静态微泡浮选柱气含率预测%Prediction of gas holdup in cyclonic-static micro-bubble flotation column based on BP neural networks

    Institute of Scientific and Technical Information of China (English)

    廖寅飞; 刘炯天; 王永田; 曹亦俊

    2011-01-01

    分析了影响旋流-静态微泡浮选柱气含率的因素,选取循环压力、进气量和起泡剂浓度3个主控因素作为BP神经网络模型的基本特征量,建立了浮选柱气含率与主控因素之间的相关关系和BP神经网络预测模型,并对气含率进行了预测分析.结果表明:BP神经网络能合理地表达浮选柱气含率与其主控因素之间的非线性映射关系,预测结果与实测值之间的相对误差一般小于5%,达到了较高的预测精度.%The factors that affect the gas holdup in cyclonic-static micro-bubble flotation column were analyzed. Taking the main controlling factors, including pressure of circulating pump, air flow and frother concentration, as the basic characteristic quantity of BP neural networks models, the correlation between the gas holdup, the factors, and the BP neural networks prediction model were proposed for prediction of the gas holdup in flotation column. The results show that the BP neural networks model can actually reflect the nonlinear relationship between the gas holdup in flotation column and main controlling factors. A better accurate prediction in which the errors between the predicted values and measured values are less than 5 % is achieved.

  6. Critical assessment of inverse gas chromatography as means of assessing surface free energy and acid-base interaction of pharmaceutical powders.

    Science.gov (United States)

    Telko, Martin J; Hickey, Anthony J

    2007-10-01

    Inverse gas chromatography (IGC) has been employed as a research tool for decades. Despite this record of use and proven utility in a variety of applications, the technique is not routinely used in pharmaceutical research. In other fields the technique has flourished. IGC is experimentally relatively straightforward, but analysis requires that certain theoretical assumptions are satisfied. The assumptions made to acquire some of the recently reported data are somewhat modified compared to initial reports. Most publications in the pharmaceutical literature have made use of a simplified equation for the determination of acid/base surface properties resulting in parameter values that are inconsistent with prior methods. In comparing the surface properties of different batches of alpha-lactose monohydrate, new data has been generated and compared with literature to allow critical analysis of the theoretical assumptions and their importance to the interpretation of the data. The commonly used (simplified) approach was compared with the more rigorous approach originally outlined in the surface chemistry literature.

  7. Physicochemical characterization of D-mannitol polymorphs: the challenging surface energy determination by inverse gas chromatography in the infinite dilution region.

    Science.gov (United States)

    Cares-Pacheco, M G; Vaca-Medina, G; Calvet, R; Espitalier, F; Letourneau, J-J; Rouilly, A; Rodier, E

    2014-11-20

    Nowadays, it is well known that surface interactions play a preponderant role in mechanical operations, which are fundamental in pharmaceutical processing and formulation. Nevertheless, it is difficult to correlate surface behaviour in processes to physical properties measurement. Indeed, most pharmaceutical solids have multiple surface energies because of varying forms, crystal faces and impurities contents or physical defects, among others. In this paper, D-mannitol polymorphs (α, β and δ) were studied through different characterization techniques highlighting bulk and surface behaviour differences. Due to the low adsorption behaviour of β and δ polymorphs, special emphasis has been paid to surface energy analysis by inverse gas chromatography, IGC. Surface energy behaviour has been studied in Henry's domain showing that, for some organic solids, the classical IGC infinite dilution zone is never reached. IGC studies highlighted, without precedent in literature, dispersive surface energy differences between α and β mannitol, with a most energetically active α form with a γ(s)(d) of 74.9 mJ·m⁻². Surface heterogeneity studies showed a highly heterogeneous α mannitol with a more homogeneous β (40.0 mJ·m⁻²) and δ mannitol (40.3 mJ·m⁻²). Moreover, these last two forms behaved similarly considering surface energy at different probe concentrations.

  8. Characterization of cis- and trans-octadecenoic acid positional isomers in edible fat and oil using gas chromatography-flame ionisation detector equipped with highly polar ionic liquid capillary column.

    Science.gov (United States)

    Yoshinaga, Kazuaki; Asanuma, Masaharu; Mizobe, Hoyo; Kojima, Koichi; Nagai, Toshiharu; Beppu, Fumiaki; Gotoh, Naohiro

    2014-10-01

    In this study, the characterisation of all cis- and trans-octadecenoic acid (C18:1) positional isomers in partially hydrogenated vegetable oil (PHVO) and milk fat, which contain several cis- and trans-C18:1 positional isomers, was achieved by gas chromatography-flame ionisation detector equipped with a highly polar ionic liquid capillary column (SLB-IL111). Prior to analysis, the cis- and trans-C18:1 fractions in PHVO and milk fat were separated using a silver-ion cartridge. The resolution of all cis-C18:1 positional isomers was successfully accomplished at the optimal isothermal column temperature of 120 °C. Similarly, the positional isomers of trans-C18:1, except for trans-6-C18:1 and trans-7-C18:1, were separated at 120 °C. The resolution of trans-6-C18:1 and trans-7-C18:1 isomers was made possible by increasing the column temperature to 160 °C. This analytical method is suitable for determining the cis- and trans-C18:1 positional isomers in edible fats and oils.

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of organochlorine pesticides and polychlorinated biphenyls in bottom sediment by dual capillary-column gas chromatography with electron-capture detection

    Science.gov (United States)

    Foreman, William T.; Connor, Brooke F.; Furlong, Edward T.; Vaught, Deborah G.; Merten, Leslie M.

    1995-01-01

    A method for the determination of 30 individual organochlorine pesticides, total toxaphene, and total polychlorinated biphenyls (PCBs) in bottom sediment is described. The method isolates the pesticides and PCBs by solvent extraction with dichlorobenzene, removes inorganic sulfur, large naturally occurring molecules, and other unwanted interferences by gel permeation chromatography, and further cleans up and class fractionates the extract using adsorption chromatography. The com- pounds then are instrumentally determined using dual capillary-column gas chromatography with electron-capture detection. Reporting limits range from 1 to 5 micrograms per kilogram for 30 individual pesticides, 50 micrograms per kilogram for total PCBs, and 200 micrograms per kilogram for total toxaphene. The method also is designed to allow the simultaneous isolation of 79 other semivolatile organic compounds from the sediment, which are separately quantified using gas chromatography with mass spectrometric detection. The method was developed in support of the U.S. Geological Survey's National Water-Quality Assessment program.

  10. Development of gas chromatography-flame ionization detection system with a single column and liquid nitrogen-free for measuring atmospheric C2-C12 hydrocarbons.

    Science.gov (United States)

    Liu, Chengtang; Mu, Yujing; Zhang, Chenglong; Zhang, Zhibo; Zhang, Yuanyuan; Liu, Junfeng; Sheng, Jiujiang; Quan, Jiannong

    2016-01-04

    A liquid nitrogen-free GC-FID system equipped with a single column has been developed for measuring atmospheric C2-C12 hydrocarbons. The system is consisted of a cooling unit, a sampling unit and a separation unit. The cooling unit is used to meet the temperature needs of the sampling unit and the separation unit. The sampling unit includes a dehydration tube and an enrichment tube. No breakthrough of the hydrocarbons was detected when the temperature of the enrichment tube was kept at -90 °C and sampling volume was 400 mL. The separation unit is a small round oven attached on the cooling column. A single capillary column (OV-1, 30 m × 0.32 mm I.D.) was used to separate the hydrocarbons. An optimal program temperature (-60 ∼ 170 °C) of the oven was achieved to efficiently separate C2-C12 hydrocarbons. There were good linear correlations (R(2)=0.993-0.999) between the signals of the hydrocarbons and the enrichment amount of hydrocarbons, and the relative standard deviation (RSD) was less than 5%, and the method detection limits (MDLs) for the hydrocarbons were in the range of 0.02-0.10 ppbv for sampling volume of 400 mL. Field measurements were also conducted and more than 50 hydrocarbons from C2 to C12 were detected in Beijing city.

  11. A Two-Dimensional Post-Stack Seismic Inversion for Acoustic Impedance of Gas and Hydrate Bearing Deep-Water Sediments Within the Continental Slope of the Ulleung Basin, East Sea, Korea

    Directory of Open Access Journals (Sweden)

    Keumsuk Lee

    2013-01-01

    Full Text Available A post-stack inversion of 2D seismic data was conducted to estimate the spatial distribution of acoustic impedance associated with gas and hydrates in the Ulleung Basin, East Sea, Korea constrained by logs from three boreholes drilled on its continental margin. A model-based inversion was applied to a Plio-Quaternary succession composed of alternations of unconsolidated mass-flow deposits/turbidites. A comparison of seismic reflections and synthetic data computed from impedance logs is shown for two zones. An upper (steep slope zone contains a moderately continuous, possibly bottom-simulating reflector feature along the corresponding section. This feature may be associated with a lithology boundary near a drill site in addition to, or instead of, a stability boundary of gas hydrates (i.e., gas below and hydrates above. The lower (gentle slope zone has locally cross-cutting reflection patterns that are more likely to be attributed to gas- and hydrate-related physical phenomena than to spatiotemporal changes in lithology. This seismic inversion is informative and useful, making a contribution to enhance the interpretability of the seismic profiles for a potential hydrate recovery.

  12. 反相气相色谱研究金属离子中介甲醛印迹聚合物的气相识别%Investigation on Gas Phase Recognition for Metal-Ion Mediated Formaldehyde Imprinted Polymer by Inversed Phase Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    李辉; 逯翠梅; 谢凤; 许苗苗; 王素素; 李志平

    2014-01-01

    A Co2+ ion-mediated formaldehyde imprinted polymer ( MIP) was prepared by coordination polymerization method in present work and its surface structure characterized by using IR spectrum and scanning electron microscope ( SEM). Inversed phase gas chromatography ( IGC) technique using this formaldehyde imprinted polymer as stationary phase was utilized to investigate on the retention selectivity, isotherm adsorption and adsorption thermodynamics for this imprint material toward the template and its structural analogue. Also, the ability of this polymer in the removal of formaldehyde from room atmosphere was explored. Results indicated that the capacity of the template on the molecularly imprinted polymers (MIPs) column was much higher than that of aldehyde and the lower column temperature and flow rate of carrier gas was beneficial for the selective retention of imprint material toward the template molecule, possessing a higher capacity factor of 61. 1 for the template and a higher separation factor of 10. 66 for this imprint polymer toward formaldehyde and aldehyde under the optimized chromatographic conditions ( column temperature: 363 K;flow rate of carrier gase: 7. 0 mL/ min; injection volume: 3. 0 μL). An approximate linear adsorption isotherm for the template and a BET Ⅲ one for the analogue on the MIPs was observed. In addition, this molecularly imprinted polymer was shown with higher capability in the removal of formaldehyde from room atmosphere.%采用配位聚合法制备了 Co2+中介的甲醛印迹聚合物,用红外光谱和扫描电镜研究了分子印迹聚合物的表面结构。以甲醛印迹聚合物作为气相色谱固定相,采用反相气相色谱技术研究了印迹材料对模板及其结构相似物的选择保留性能、等温吸附及吸附热力学,并探讨了分子印迹聚合物对室内空气中甲醛的脱除效果。结果表明,在相同色谱条件下,分子印迹柱对模板分子的容量因子均远高于乙醛。

  13. 催化干气回收乙烯装置中脱碳塔内件形式优化改造%Optimal Modification of Internals in Decarbonization Column of Catalytic Dry Gas Ethylene Recovery Unit

    Institute of Scientific and Technical Information of China (English)

    刘玉花

    2016-01-01

    脱碳塔是影响催化干气回收乙烯装置处理量的瓶颈。装置低负荷运行时脱碳塔操作平稳,而负荷升高时塔顶部分液罐中液位升高,操作不正常,净化气带胺液跑损严重。分析了脱碳塔的特殊性,结合现场操作存在问题,选用消泡型内件及填料对脱碳塔进行改造,改造后装置操作弹性增加,处理能力提高,脱碳塔胺液夹带现象明显降低,胺液补充量显著减少,经济效益显著,可为类似系统内件改造提供借鉴。%Decarbonization column is the bottleneck which affecting the capacity of the catalytic dry gas ethylene recovery unit.When the unit operating in low load,the decarbonization column under steady state.However,when the operation load increase,the liquid level of the liquid sep-arate pot will rise and the operation state gets bad.The particularity of decarbonization column is analyzed and combined with the problems encountered in actual operating situation,and the opti-mal modification of the internals in decarbonization column is put forward.Through selecting the defoaming internals and modifying,the flexibility of the operation and the capacity of the unit is increased.Moreover,the amine liquid consumption is decreased obviously and the economic bene-fit is remarkable.An important reference for the similar device is provided.

  14. Methods of analysis by the U. S. Geological Survey National Water Quality Laboratory - determination of organonitrogen herbicides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    Science.gov (United States)

    Sandstrom, Mark W.; Wydoski, Duane S.; Schroeder, Michael P.; Zamboni, Jana L.; Foreman, William T.

    1992-01-01

    A method for the isolation of organonitrogen herbicides from natural water samples using solid-phase extraction and analysis by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction cartridges containing octadecyl-bonded porous silica to remove the herbicides. The cartridges are dried using carbon dioxide, and adsorbed herbicides are removed from the cartridges by elution with 1.8 milliliters of hexaneisopropanol (3:1). Extracts of the eluants are analyzed by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of at least three characteristic ions. The method detection limits are dependent on sample matrix and each particular herbicide. The method detection limits, based on a 100-milliliter sample size, range from 0.02 to 0.25 microgram per liter. Recoveries averaged 80 to 115 percent for the 23 herbicides and 2 metabolites in 1 reagent-water and 2 natural-water samples fortified at levels of 0.2 and 2.0 micrograms per liter.

  15. Preparation and Separation Performance of Three New Gas Chromatography Capillary Columns Coated with Cyclodextrin Derivatives%环糊精衍生物涂渍毛细管柱的制备及分离性能

    Institute of Scientific and Technical Information of China (English)

    颜霞; 方智利; 林纯; 王国梁; 范军; 郑盛润; 贾成俊; 章伟光

    2013-01-01

    以3种环糊精衍生物分别涂覆在毛细管内壁制得气相色谱毛细管柱,以正十二烷为溶质,测得理论塔板数均在2800/m以上,柱效较高.研究了它们对一系列苯系物位置异构体的分离性能,探讨了硝基氯苯、硝基苯胺和苯二胺等化合物在不同柱上的拆分机理.底物分子和固定相之间的弱相互作用(如氢键、偶极相互作用和π-π堆积作用)等直接影响毛细管柱对底物的分离性能.对于苯二胺的位置异构体,在全对氯苯异氰酸酯化β-CD涂覆的毛细管柱(ACD)上的分离因子为1.88,在多叠氮β-CD衍生物涂覆的毛细管柱(NMCD)上的分离因子为1.41,但在单叠氮β-CD衍生物涂覆的毛细管柱(NSCD)上无法分开;对于硝基氯苯,在NMCD柱和ACD柱上的分离因子相近(前者为1.13/1.11;后者为1.08/1.15),在NSCD柱上则无分离趋势;对于硝基苯胺,在NMCD柱上无分离趋势.同时,苯环上不同取代基间电子效应则影响了异构体在气相色谱中出峰顺序.%Three kinds of capillary columns were obtained by coating cyclodextrin derivatives onto inner surface of fused capillary.According to the literature's method,all the theoretical plate numbers are over 2800/m by using n-dodecane,indicating that they have high column efficiencies.Then,separation and mechanism of isomeric benzene derivatives,such as nitrochlorobenzene,nitroaniline,and phenylenediamine by capillary column gas chromatography have been investigated in detail.The interactions such as hydrogen bonding,dipolar-dipolar attraction and π-π stacking between analytes and stationary phases have significant effect on the separation performances of these capillary columns.For phenylenediamine,separation factors on the heptakis (6-azido-6-deoxy-2,3-di-O-p-chlorophenylcarbamoylated)-b-CD (NMCD) and per(pchlorophenylcarbamoylated)-b-CD(ACD) columns are 1.41 and 1.88,respectively,however the positional isomers can not be separated on the NSCD column

  16. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    Science.gov (United States)

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  17. Spatial and Temporal Variability of Trace Gas Columns Derived from WRF/Chem Regional Model Output: Planning for Geostationary Observations of Atmospheric Composition

    Science.gov (United States)

    Follette-Cook, M. B.; Pickering, K.; Crawford, J.; Duncan, B.; Loughner, C.; Diskin, G.; Fried, A.; Weinheimer, A.

    2015-01-01

    We quantify both the spatial and temporal variability of column integrated O3, NO2, CO, SO2, and HCHO over the Baltimore / Washington, DC area using output from the Weather Research and Forecasting model with on-line chemistry (WRF/Chem) for the entire month of July 2011, coinciding with the first deployment of the NASA Earth Venture program mission Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ). Using structure function analyses, we find that the model reproduces the spatial variability observed during the campaign reasonably well, especially for O3. The Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument will be the first NASA mission to make atmospheric composition observations from geostationary orbit and partially fulfills the goals of the Geostationary Coastal and Air Pollution Events (GEO-CAPE) mission. We relate the simulated variability to the precision requirements defined by the science traceability matrices of these space-borne missions. Results for O3 from 0- 2 km altitude indicate that the TEMPO instrument would be able to observe O3 air quality events over the Mid-Atlantic area, even on days when the violations of the air quality standard are not widespread. The results further indicated that horizontal gradients in CO from 0-2 km would be observable over moderate distances (= 20 km). The spatial and temporal results for tropospheric column NO2 indicate that TEMPO would be able to observe not only the large urban plumes at times of peak production, but also the weaker gradients between rush hours. This suggests that the proposed spatial and temporal resolutions for these satellites as well as their prospective precision requirements are sufficient to answer the science questions they are tasked to address.

  18. Inverse Limits

    CERN Document Server

    Ingram, WT

    2012-01-01

    Inverse limits provide a powerful tool for constructing complicated spaces from simple ones. They also turn the study of a dynamical system consisting of a space and a self-map into a study of a (likely more complicated) space and a self-homeomorphism. In four chapters along with an appendix containing background material the authors develop the theory of inverse limits. The book begins with an introduction through inverse limits on [0,1] before moving to a general treatment of the subject. Special topics in continuum theory complete the book. Although it is not a book on dynamics, the influen

  19. Automated Composite Column Wrapping

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    The Automated Composite Column Wrapping is performed by a patented machine known as Robo-Wrapper. Currently there are three versions of the machine available for bridge retrofit work depending on the size of the columns being wrapped. Composite column retrofit jacket systems can be structurally just as effective as conventional steel jacketing in improving the seismic response characteristics of substandard reinforced concrete columns.

  20. Enantiomeric separation of chiral polychlorinated biphenyls on B-cyclodextrin capillary columns by means of heart-cut multidimensional gas chromatography and comprehensive two-dimensional gas chromatography. Application to food samples

    NARCIS (Netherlands)

    Bordajandi, L.R.; Korytar, P.; Boer, de J.; Gonzalez, M.J.

    2005-01-01

    Three commercially available chiral capillary columns, Chirasil-Dex, BGB-176SE. and BGB-172, have been evaluated for the separation into enantiomers of the 19 chiral polychlorinated biphenyls (PCB) congeners stable at room temperature. The enantiomers of 15 chiral PCBs were, at least to some extent,

  1. Determination of lignin in marine sediment using alkaline cupric oxide oxidation-solid phase extraction-on-column derivatization-gas chromatography

    Science.gov (United States)

    Zhang, Ting; Li, Xianguo; Sun, Shuwen; Lan, Haiqing; Du, Peirui; Wang, Min

    2013-03-01

    Lignin serves as one of the most important molecular fossils for tracing Terrestrial Organic Matters (TOMs) in marine environment. Extraction and derivatization of lignin oxidation products (LOPs) are crucial for accurate quantification of lignin in marine sediment. Here we report a modification of the conventional alkaline cupric oxide (CuO) oxidation method, the modification consisting in a solid phase extraction (SPE) and a novel on-column derivatization being employed for better efficiency and reproducibility. In spiking blanks, recoveries with SPE for the LOPs are between 77.84% and 99.57% with relative standard deviations (RSDs) ranging from 0.57% to 8.04% ( n=3), while those with traditional liquid-liquid extraction (LLE) are from 44.52% to 86.16% with RSDs being from 0.53% to 13.14% ( n=3). Moreover, the reproducibility is greatly improved with SPE, with less solvent consumption and shorter processing time. The average efficiency of on-column derivatization for LOPs is 100.8% ± 0.68%, which is significantly higher than those of in-vial or in-syringe derivatization, thus resulting in still less consumption of derivatizing reagents. Lignin in the surface sediments sampled from the south of Yangtze River estuary, China, was determined with the established method. Recoveries of 72.66% to 85.99% with standard deviation less than 0.01mg/10g dry weight are obtained except for p-hydroxyben-zaldehyde. The lignin content Σ8 (produced from 10 g dry sediment) in the research area is between 0.231 and 0.587 mg. S/V and C/V ratios (1.028 ± 0.433 and 0.192 ± 0.066, respectively) indicate that the TOMs in this region are originated from a mixture of woody and nonwoody angiosperm plants; the high values of (Ad/Al)v suggest that the TOMs has been highly degraded.

  2. Beam Studies with Electron Columns

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V.; Valishev, A.; Kuznetsov, G.; /Fermilab; Kamerdzhiev, V.; /Julich, Forschungszentrum; Romanov, A.; /Novosibirsk, IYF

    2009-04-01

    We report preliminary results of experimental studies of 'electron columns' in the Tevatron and in a specialized test setup. In the Tevatron, a beam of 150 GeV protons ionizes residual gas and ionization electrons are stored in an electrostatic trap immersed into strong longitudinal magnetic field. Shifts of proton betatron frequencies are observed. In the test setup, we observe effects pointing to accumulation and escape of ionization electrons.

  3. Mechanistic model for dispersion coefficients in bubble column

    CSIR Research Space (South Africa)

    Skosana, PJ

    2015-05-01

    Full Text Available A mechanistic model describing the mass and momentum exchange in bubble columns is proposed that is based on the observations that the gas distribution in a bubble column is not uniform across the column and that as a consequence large liquid...

  4. Temperature-compensated 8-bit column driver for AMLCD

    Science.gov (United States)

    Dingwall, Andrew G. F.; Lin, Mark L.

    1995-06-01

    An all-digital, 5 V input, 50 Mhz bandwidth, 10-bit resolution, 128- column, AMLCD column driver IC has been designed and tested. The 10-bit design can enhance display definition over 6-bit nd 8-bit column drivers. Precision is realized with on-chip, switched-capacitor DACs plus transparently auto-offset-calibrated, opamp outputs. Increased resolution permits multiple 10-bit digital gamma remappings in EPROMs over temperature. Driver IC features include externally programmable number of output column, bi-directional digital data shifting, user- defined row/column/pixel/frame inversion, power management, timing control for daisy-chained column drivers, and digital bit inversion. The architecture uses fewer reference power supplies.

  5. Characterization of sulfur and nitrogen compounds in Brazilian petroleum derivatives using ionic liquid capillary columns in comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection.

    Science.gov (United States)

    Cappelli Fontanive, Fernando; Souza-Silva, Érica Aparecida; Macedo da Silva, Juliana; Bastos Caramão, Elina; Alcaraz Zini, Claudia

    2016-08-26

    Diesel and naphtha samples were analyzed using ionic liquid (IL) columns to evaluate the best column set for the investigation of organic sulfur compounds (OSC) and nitrogen(N)-containing compounds analyses with comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry detector (GC×GC/TOFMS). Employing a series of stationary phase sets, namely DB-5MS/DB-17, DB-17/DB-5MS, DB-5MS/IL-59, and IL-59/DB-5MS, the following parameters were systematically evaluated: number of tentatively identified OSC, 2D chromatographic space occupation, number of polyaromatic hydrocarbons (PAH) and OSC co-elutions, and percentage of asymmetric peaks. DB-5MS/IL-59 was chosen for OSC analysis, while IL59/DB-5MS was chosen for nitrogen compounds, as each stationary phase set provided the best chromatographic efficiency for these two classes of compounds, respectively. Most compounds were tentatively identified by Lee and Van den Dool and Kratz retention indexes, and spectra-matching to library. Whenever available, compounds were also positively identified via injection of authentic standards.

  6. Electron transfer and ionic displacements at the origin of the 2D electron gas at the LAO/STO interface: direct measurements with atomic-column spatial resolution.

    Science.gov (United States)

    Cantoni, Claudia; Gazquez, Jaume; Miletto Granozio, Fabio; Oxley, Mark P; Varela, Maria; Lupini, Andrew R; Pennycook, Stephen J; Aruta, Carmela; di Uccio, Umberto Scotti; Perna, Paolo; Maccariello, Davide

    2012-08-02

    Using state-of-the-art, aberration-corrected scanning transmission electron microscopy and electron energy loss spectroscopy with atomic-scale spatial resolution, experimental evidence for an intrinsic electronic reconstruction at the LAO/STO interface is shown. Simultaneous measurements of interfacial electron density and system polarization are crucial for establishing the highly debated origin of the 2D electron gas. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Modeling Stone Columns

    Directory of Open Access Journals (Sweden)

    Jorge Castro

    2017-07-01

    Full Text Available This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the “unit cell”, longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns.

  8. Modeling Stone Columns

    Science.gov (United States)

    2017-01-01

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the “unit cell”, longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns. PMID:28773146

  9. Inverse disjuncties

    NARCIS (Netherlands)

    Malepaard, J.

    2007-01-01

    Balansschikkingen (of negatief gebonden of-constructies) zijn volgens de in dit artikel ontwikkelde hypothese inverse disjuncties (id's). Het zijn tweeledige zinnen waarvan het eerste lid een verplichte negatieve of minimaliserende constituent bevat en het tweede lid met of begint. Evenals

  10. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  11. Determination of hexavalent chromium concentration in industrial waste incinerator stack gas by using a modified ion chromatography with post-column derivatization method.

    Science.gov (United States)

    Miyake, Yuichi; Tokumura, Masahiro; Iwazaki, Yuta; Wang, Qi; Amagai, Takashi; Horii, Yuichi; Otsuka, Hideyuki; Tanikawa, Noboru; Kobayashi, Takeshi; Oguchi, Masahiro

    2017-06-16

    An ion chromatography with post-column derivatization with 1,5-diphenylcarbazide (IC-DPC) analytical method was modified to enable measurement of trace-level hexavalent chromium (Cr(VI)) in air. One of the difficulties in determining trace levels of Cr(VI) in air with conventional IC-DPC methods is co-elution of the solvent and ion peaks due to high concentrations of ionic compounds in the extract. However, by using gradient elution rather than isocratic elution we were able to fully resolve the Cr(VI) ion peak from the solvent peak without the need for diluting the extract, which would have reduced the minimum quantifiable level of the method. With this method, we were able to detect Cr(VI) in air at concentrations of 5.3ng/m(3) (assuming a sampling volume of 1m(3) and a final solution volume of 10mL). Recovery tests at three different concentrations of Cr(VI) (50, 250, 1000ng) were performed with or without fly ash; recovery rates at all the concentrations of Cr(VI), with or without fly ash, ranged from 68% to 110% (mean±relative standard deviation, 96%±11%), and there were no differences in recovery rates with respect to the presence or absence of fly ash. Finally, we used the developed method to determine the concentration of Cr(VI) in stack gases collected from eight industrial waste incinerators located in Japan. The concentration of Cr(VI) in the stack gases ranged from below the method quantification limit to 3100ng/m(3). The highest concentrations of Cr(VI) detected in the stack gases were two to three orders of magnitude higher than that in ambient air in Japan. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Analysis of Listeria using exogenous volatile organic compound metabolites and their detection by static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS).

    Science.gov (United States)

    Taylor, Carl; Lough, Fraser; Stanforth, Stephen P; Schwalbe, Edward C; Fowlis, Ian A; Dean, John R

    2017-07-01

    Listeria monocytogenes is a Gram-positive bacterium and an opportunistic food-borne pathogen which poses significant risk to the immune-compromised and pregnant due to the increased likelihood of acquiring infection and potential transmission of infection to the unborn child. Conventional methods of analysis suffer from either long turn-around times or lack the ability to discriminate between Listeria spp. reliably. This paper investigates an alternative method of detecting Listeria spp. using two novel enzyme substrates that liberate exogenous volatile organic compounds in the presence of α-mannosidase and D-alanyl aminopeptidase. The discriminating capabilities of this approach for identifying L. monocytogenes from other species of Listeria are investigated. The liberated volatile organic compounds (VOCs) are detected using an automated analytical technique based on static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS). The results obtained by SHS-MCC-GC-IMS are compared with those obtained by the more conventional analytical technique of headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The results found that it was possible to differentiate between L. monocytogenes and L. ivanovii, based on their VOC response from α-mannosidase activity.

  13. Modeling of column apparatus processes

    CERN Document Server

    Boyadjiev, Christo; Boyadjiev, Boyan; Popova-Krumova, Petya

    2016-01-01

    This book presents a new approach for the modeling of chemical and interphase mass transfer processes in industrial column apparatuses, using convection-diffusion and average-concentration models. The convection-diffusion type models are used for a qualitative analysis of the processes and to assess the main, small and slight physical effects, and then reject the slight effects. As a result, the process mechanism can be identified. It also introduces average concentration models for quantitative analysis, which use the average values of the velocity and concentration over the cross-sectional area of the column. The new models are used to analyze different processes (simple and complex chemical reactions, absorption, adsorption and catalytic reactions), and make it possible to model the processes of gas purification with sulfur dioxide, which form the basis of several patents.

  14. A New Two-fluid Radiation-hydrodynamical Model for X-Ray Pulsar Accretion Columns

    Science.gov (United States)

    West, Brent F.; Wolfram, Kenneth D.; Becker, Peter A.

    2017-02-01

    Previous research centered on the hydrodynamics in X-ray pulsar accretion columns has largely focused on the single-fluid model, in which the super-Eddington luminosity inside the column decelerates the flow to rest at the stellar surface. This type of model has been relatively successful in describing the overall properties of the accretion flows, but it does not account for the possible dynamical effect of the gas pressure. On the other hand, the most successful radiative transport models for pulsars generally do not include a rigorous treatment of the dynamical structure of the column, instead assuming an ad hoc velocity profile. In this paper, we explore the structure of X-ray pulsar accretion columns using a new, self-consistent, “two-fluid” model, which incorporates the dynamical effect of the gas and radiation pressures, the dipole variation of the magnetic field, the thermodynamic effect of all of the relevant coupling and cooling processes, and a rigorous set of physical boundary conditions. The model has six free parameters, which we vary in order to approximately fit the phase-averaged spectra in Her X-1, Cen X-3, and LMC X-4. In this paper, we focus on the dynamical results, which shed new light on the surface magnetic field strength, the inclination of the magnetic field axis relative to the rotation axis, the relative importance of gas and radiation pressures, and the radial variation of the ion, electron, and inverse-Compton temperatures. The results obtained for the X-ray spectra are presented in a separate paper.

  15. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Wastewater Compounds by Polystyrene-Divinylbenzene Solid-Phase Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.; Barber, Larry B.; Burkhardt, Mark R.

    2002-01-01

    A method for the determination of 67 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals in wastewater on aquatic organisms. This method also may be useful for evaluating the impact of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are an indicator of wastewater or that have been chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclicaromatic hydrocarbons, and high-use domestic pesticides. Water samples are filtered to remove suspended particulate matter and then are extracted by vacuum through disposable solid-phase cartridges that contain polystyrene-divinylbenzene resin. Cartridges are dried with nitrogen gas, and then sorbed compounds are eluted with dichloromethane-diethyl ether (4:1) and determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 4 micrograms per liter averaged 74 percent ? 7 percent relative standard deviation for all method compounds. Initial method detection limits for single-component compounds (excluding hormones and sterols) averaged 0.15 microgram per liter. Samples are preserved by filtration, the addition of 60 grams NaCl, and storage at 4 degrees Celsius. The laboratory has established a sample-holding time (prior to sample extraction) of 14 days from the date of sample collection until a statistically accepted method can be used to determine the effectiveness of these sample-preservation procedures.

  16. Unraveling the Active Site in Copper-ceria Systems for the Water Gas Shift Reaction: In-situ Characterization of an Inverse Powder CeO2-x/CuO-Cu Catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, J.A.; Barrio, L.; Estrella, M.; Zhou, G.; Wen, W.; Hanson, J.C.; Hungría, A.B.; Hornés, A.; Fernández-García, M.; Arturo Martínez-Arias, A.

    2010-03-04

    An inverse powder system composed of CeO{sub 2} nanoparticles dispersed over a CuO-Cu matrix is proposed as a novel catalyst for the water-gas shift reaction. This inverse CeO{sub 2}/CuO-Cu catalyst exhibits a higher activity than standard Cu/CeO{sub 2} catalysts. In situ synchrotron characterization techniques were employed to follow the structural changes of CeO{sub 2}/CuO-Cu under reaction conditions. Time-resolved X-ray diffraction experiments showed the transformation of CuO to metallic Cu via a Cu{sub 2}O intermediate. Short-order structural changes were followed by pair distribution function analysis and corroborated the results obtained by diffraction. Moreover, X-ray absorption spectroscopy also revealed oxidation state changes from Cu{sup 2+} to Cu{sup 0} and the partial reduction of CeOx nanoparticles. The activity data obtained by mass spectrometry revealed that hydrogen production starts once the copper has been fully reduced. The strong interaction of ceria and copper boosted the catalytic performance of the sample. The inverse catalyst was active at low temperatures, stable to several reaction runs and to redox cycles. These characteristics are highly valuable for mobile fuel cell applications. The active phases of the inverse CeO{sub 2}/CuO-Cu catalyst are partially reduced ceria nanoparticles strongly interacting with metallic copper. The nature and structure of the ceria nanoparticles are of critical importance because they are involved in processes related to water dissociation over the catalyst surface.

  17. Unraveling the Active Site in Copper-Ceria Systems for the Water-Gas Shift Reaction: In Situ Characterization of an Inverse Powder CeO2-x/CuO-Cu Catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Barrio, L.; Estrella, M; Zhou, G; Wen, W; Hanson, J; Hungria, A; Hornes, A; Fernandez-Garcia, M; Martinez-Arias, A; Rodriguez, J

    2010-01-01

    An inverse powder system composed of CeO{sub 2} nanoparticles dispersed over a CuO-Cu matrix is proposed as a novel catalyst for the water-gas shift reaction. This inverse CeO{sub 2}/CuO-Cu catalyst exhibits a higher activity than standard Cu/CeO{sub 2} catalysts. In situ synchrotron characterization techniques were employed to follow the structural changes of CeO{sub 2}/CuO-Cu under reaction conditions. Time-resolved X-ray diffraction experiments showed the transformation of CuO to metallic Cu via a Cu{sub 2}O intermediate. Short-order structural changes were followed by pair distribution function analysis and corroborated the results obtained by diffraction. Moreover, X-ray absorption spectroscopy also revealed oxidation state changes from Cu{sup 2+} to Cu{sup 0} and the partial reduction of CeO{sub x} nanoparticles. The activity data obtained by mass spectrometry revealed that hydrogen production starts once the copper has been fully reduced. The strong interaction of ceria and copper boosted the catalytic performance of the sample. The inverse catalyst was active at low temperatures, stable to several reaction runs and to redox cycles. These characteristics are highly valuable for mobile fuel cell applications. The active phases of the inverse CeO{sub 2}/CuO-Cu catalyst are partially reduced ceria nanoparticles strongly interacting with metallic copper. The nature and structure of the ceria nanoparticles are of critical importance because they are involved in processes related to water dissociation over the catalyst surface.

  18. Study on Calculation Method of Liquid Holdup of Gas-Liquid Two-phase Flow in Inclined Tube Column%倾斜管柱气液两相流持液率计算方法研究

    Institute of Scientific and Technical Information of China (English)

    曾祥柱; 罗威; 刘政轩; 张瑞尧

    2016-01-01

    The calculation method of liquid holdup of gas-liquid two-phase flow in inclined tube column plays an important role in petroleum industry. In this paper, Beggs-Brill correlation, Mukherjee-Brill correlation, Eaton correlation and Dukler II correlation formula were used to calculate liquid holdup. Through experiments, the liquid holdup in inclined tube column with different angles under the same gas liquid volume flow rate was tested, and the accuracies of the four formulas were analyzed. The results showed that Beggs-Brill correlation was more accurate. The Beggs Brill correlation were analyzed. It's found that when the other conditions are the same, the calculated liquid holdup has symmetry with the tube column tilting angle, symmetry axis is 50 degrees, calculated liquid holdups of tilt angle of 90 degrees and 10 degrees are equal. Combined with the measured experimental data, the drawn curve shows that liquid holdup between 45 and 60 degrees inclination angle is the maximum, and the liquid holdup of 90 degree is close to the liquid holdup of 10 degrees, on the whole, the liquid holdup has a certain symmetry with the change of the angle.%倾斜管柱气液两相流持液率的计算方法在石油工业中具有重要地位。采用 Beggs-Brill 相关式、Mukherjee-Brill 相关式、Eaton 相关式和杜克勒Ⅱ相关式计算了倾斜管柱的持液率,通过实验手段测量相同气液体积流量下,不同角度的持液率数据,分析了上述4种计算式的准确性,发现 Beggs-Brill 相关式比较准确。对Beggs-Brill 相关式进行了分析,发现当其他条件一定时,其计算的持液率关于管柱倾斜角度具有一定的对称性,对称轴为50°,倾斜角度为90°时和10°时计算的持液率相等,结合所测量的实验数据,做出曲线发现在倾斜角度在45°到60°之间持液率最大,倾斜角度为90°的持液率与为10°的持液率比较接近,同时持液率随角度的变化具有一定的对称性。

  19. Methods of analysis and quality-assurance practices of the U.S. Geological Survey organic laboratory, Sacramento, California; determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Crepeau, Kathryn L.; Domagalski, Joseph L.; Kuivila, Kathryn M.

    1994-01-01

    Analytical method and quality-assurance practices were developed for a study of the fate and transport of pesticides in the Sacramento-San Joaquin Delta and the Sacramento and San Joaquin River. Water samples were filtered to remove suspended parti- culate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide, and the pesticides were eluted with three 2-milliliter aliquots of hexane:diethyl ether (1:1). The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for analytes determined per 1,500-milliliter samples ranged from 0.006 to 0.047 microgram per liter. Recoveries ranged from 47 to 89 percent for 12 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.05 and 0.26 microgram per liter. The method was modified to improve the pesticide recovery by reducing the sample volume to 1,000 milliliters. Internal standards were added to improve quantitative precision and accuracy. The analysis also was expanded to include a total of 21 pesticides. The method detection limits for 1,000-milliliter samples ranged from 0.022 to 0.129 microgram per liter. Recoveries ranged from 38 to 128 percent for 21 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.10 and 0.75 microgram per liter.

  20. JCE Feature Columns

    Science.gov (United States)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  1. Glass-silicon column

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Conrad M.

    2003-12-30

    A glass-silicon column that can operate in temperature variations between room temperature and about 450.degree. C. The glass-silicon column includes large area glass, such as a thin Corning 7740 boron-silicate glass bonded to a silicon wafer, with an electrode embedded in or mounted on glass of the column, and with a self alignment silicon post/glass hole structure. The glass/silicon components are bonded, for example be anodic bonding. In one embodiment, the column includes two outer layers of silicon each bonded to an inner layer of glass, with an electrode imbedded between the layers of glass, and with at least one self alignment hole and post arrangement. The electrode functions as a column heater, and one glass/silicon component is provided with a number of flow channels adjacent the bonded surfaces.

  2. Seismic processing in the inverse data space

    NARCIS (Netherlands)

    Berkhout, A.J.

    2006-01-01

    Until now, seismic processing has been carried out by applying inverse filters in the forward data space. Because the acquired data of a seismic survey is always discrete, seismic measurements in the forward data space can be arranged conveniently in a data matrix (P). Each column in the data matrix

  3. Effect of Solid Properties on Axial Liquid Dispersion in Bubble Column

    Directory of Open Access Journals (Sweden)

    Ali Raad Mohammed Jawad

    2012-01-01

    Full Text Available Experiments were conducted to study axial liquid dispersion coefficient in slurry bubble column of 0.15 m inside diameter and 1.6 m height using perforated plate gas distributor of 54 holes of a size equal to 1 mm diameter and with a 0.24 free area of holes to the cross sectional area of the column. The three phase system consists of air, water and PVC used as the solid phase. The effect of solid loading (0, 30 and 60 kg/m3 and solid diameter (0.7, 1.5 and 3 mm on the axial liquid dispersion coefficient at different axial location (25, 50 and 75 cm and superficial gas velocity covered homogeneous-heterogeneous flow regime (1-10 cm/s were studied in the present work. The results show that the axial liquid dispersion coefficient increases with increasing superficial gas velocity, axial distance, solid concentration and an inverse relationship with particles diameter

  4. Distillation Column Flooding Predictor

    Energy Technology Data Exchange (ETDEWEB)

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid

  5. Bayesian statistical modeling of spatially correlated error structure in atmospheric tracer inverse analysis

    Directory of Open Access Journals (Sweden)

    C. Mukherjee

    2011-01-01

    Full Text Available Inverse modeling applications in atmospheric chemistry are increasingly addressing the challenging statistical issues of data synthesis by adopting refined statistical analysis methods. This paper advances this line of research by addressing several central questions in inverse modeling, focusing specifically on Bayesian statistical computation. Motivated by problems of refining bottom-up estimates of source/sink fluxes of trace gas and aerosols based on increasingly high-resolution satellite retrievals of atmospheric chemical concentrations, we address head-on the need for integrating formal spatial statistical methods of residual error structure in global scale inversion models. We do this using analytically and computationally tractable spatial statistical models, know as conditional autoregressive spatial models, as components of a global inversion framework. We develop Markov chain Monte Carlo methods to explore and fit these spatial structures in an overall statistical framework that simultaneously estimates source fluxes. Additional aspects of the study extend the statistical framework to utilize priors in a more physically realistic manner, and to formally address and deal with missing data in satellite retrievals. We demonstrate the analysis in the context of inferring carbon monoxide (CO sources constrained by satellite retrievals of column CO from the Measurement of Pollution in the Troposphere (MOPITT instrument on the TERRA satellite, paying special attention to evaluating performance of the inverse approach using various statistical diagnostic metrics. This is developed using synthetic data generated to resemble MOPITT data to define a~proof-of-concept and model assessment, and then in analysis of real MOPITT data.

  6. C+/H2 gas in star-forming clouds and galaxies

    Science.gov (United States)

    Nordon, Raanan; Sternberg, Amiel

    2016-11-01

    We present analytic theory for the total column density of singly ionized carbon (C+) in the optically thick photon dominated regions (PDRs) of far-UV irradiated (star-forming) molecular clouds. We derive a simple formula for the C+ column as a function of the cloud (hydrogen) density, the far-UV field intensity, and metallicity, encompassing the wide range of galaxy conditions. When assuming the typical relation between UV and density in the cold neutral medium, the C+ column becomes a function of the metallicity alone. We verify our analysis with detailed numerical PDR models. For optically thick gas, most of the C+ column is mixed with hydrogen that is primarily molecular (H2), and this `C+/H2' gas layer accounts for almost all of the `CO-dark' molecular gas in PDRs. The C+/H2 column density is limited by dust shielding and is inversely proportional to the metallicity down to ˜0.1 solar. At lower metallicities, H2 line blocking dominates and the C+/H2 column saturates. Applying our theory to CO surveys in low-redshift spirals, we estimate the fraction of C+/H2 gas out of the total molecular gas to be typically ˜0.4. At redshifts 1 < z < 3 in massive disc galaxies the C+/H2 gas represents a very small fraction of the total molecular gas (≲ 0.16). This small fraction at high redshifts is due to the high gas surface densities when compared to local galaxies.

  7. Topological inverse semigroups

    Institute of Scientific and Technical Information of China (English)

    ZHU Yongwen

    2004-01-01

    That the projective limit of any projective system of compact inverse semigroups is also a compact inverse semigroup,the injective limit of any injective system of inverse semigroups is also an inverse semigroup, and that a compact inverse semigroup is topologically isomorphic to a strict projective limit of compact metric inverse semigroups are proved. It is also demonstrated that Horn (S,T) is a topological inverse semigroup provided that S or T is a topological inverse semigroup with some other conditions. Being proved by means of the combination of topological semigroup theory with inverse semigroup theory,all these results generalize the corresponding ones related to topological semigroups or topological groups.

  8. Determination of the Mercury Alkyl Mercuryalkylide in Municipal Sewage by Gas Chromatography Method Using DB-WAX Capillary Column%毛细管柱气相色谱法测定城市污水中烷基汞

    Institute of Scientific and Technical Information of China (English)

    张继蓉; 印成; 周金元

    2015-01-01

    A gas chromatography method using DB-WAX capillary column was established to determine the mercury alkyl mercuryalkylide in municipal sewage.On optimum condition , the measurement range was 0.10~1.00 mg/L, the correlation coefficient of methylmercury was 0.9998 , the correlation coefficient of ethylmercury was 0.9999.When 1 L water sample was taken , the detection limit of methylmercury was 6.9 ng/L, the detection limit of ethylmercury was 4.4 ng/L.Through the recovery of standard addition , the recovery rate of methylmercury and ethylmercury was in the ring of 90%~105%, the RSD was less than 1%.%建立了DB-WAX毛细管柱气相色谱法测定城市污水中烷基汞的方法。在优化条件下,测定范围为0.10~1.00 mg/L,甲基汞和乙基汞的相关系数分别为R=0.9998、0.9999。当水样取1 L时,甲基汞检出限为6.9 ng/L,乙基汞检出限为4.4 ng/L。通过基体加标回收,甲基汞和乙基汞的回收率均可控制在90%~105%之间,测定结果的RSD均<1%。

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organophosphate pesticides in whole water by continuous liquid-liquid extraction and capillary-column gas chromatography with flame photometric detection

    Science.gov (United States)

    Jha, Virendra K.; Wydoski, Duane S.

    2003-01-01

    A method for the isolation of 20 parent organophosphate pesticides and 5 organophosphate pesticide degradates from natural-water samples is described. Compounds are extracted from water samples with methylene chloride using a continuous liquid-liquid extractor for 6 hours. The solvent is evaporated using heat and a flow of nitrogen to a volume of 1 milliliter and solvent exchanged to ethyl acetate. Extracted compounds are determined by capillary-column gas chromatography with flame photometric detection. Single-operator derived method detection limits in three water-matrix samples ranged from 0.003 to 0.009 microgram per liter. Method performance was validated by spiking all compounds in three different matrices at three different concentrations. Eight replicates were analyzed at each concentration in each matrix. Mean recoveries of most method compounds spiked in surface-water samples ranged from 54 to 137 percent and those in ground-water samples ranged from 40 to 109 percent for all pesticides. Recoveries in reagent-water samples ranged from 42 to 104 percent for all pesticides. The only exception was O-ethyl-O-methyl-S-propylphosphorothioate, which had variable recovery in all three matrices ranging from 27 to 79 percent. As a result, the detected concentration of O-ethyl-O-methyl-S-propylphosphorothioate in samples is reported in this method with an estimated remark code. Based on the performance issue, two more compounds, disulfoton and ethion monoxon, also will be reported in this method with an estimated remark code. Estimated-value compounds, which are ?E-coded? in the data base, do not meet the performance criteria for unqualified quantification, but are retained in the method because the compounds are important owing to high use or potential environmental effects and because analytical performance has been consistent and reproducible.

  10. Point source emission rate estimates from MAMAP airborne remote sensing total column observations of atmospheric CO2 and CH4

    Science.gov (United States)

    Krings, Thomas; Gerilowski, Konstantin; Buchwitz, Michael; Hartmann, Jörg; Sachs, Torsten; Erzinger, Jörg; Burrows, John P.; Bovensmann, Heinrich

    2013-04-01

    Large parts of the anthropogenic greenhouse gas emissions of CO2 and CH4 are released from localised and point sources such as power plants or as fugitive emissions from fossil fuel mining and production sites. These emissions, however, are often not readily assessed by current measurement systems and networks. A tool developed to better understand point sources of CO2 and CH4 is the optical remote sensing instrument MAMAP (Methane Airborne MAPer), operated from aircraft. After a recent instrument modification, retrievals of the column averaged dry air mole fractions for methane XCH4 (or for carbon dioxide XCO2) derived from MAMAP observations in the short-wave infrared, have a precision of about 0.4% significantly improving data quality. MAMAP total column data also serve as a testbed for inversion concepts for greenhouse gas emissions from point sources using total column atmospheric concentration measurements. As information on wind speed is an important input parameter for the inference of emission rates using MAMAP data, recent measurement campaigns comprised an in-situ wind probe operated onboard the same aircraft. Incorporation of these wind measurements in combination with model data leads to a large reduction of uncertainties on the inversion result. Using the examples of two coal mine ventilation shafts in Western Germany as well as other anthropogenic targets, the value of high resolution total column data to obtain emission rate estimates is demonstrated. MAMAP has also been tested in sunglint geometry over the ocean and has therefore the potential for application also to offshore emission sites.

  11. If You Were a Molecule in a Chromatography Column, What Would You See?

    Science.gov (United States)

    Mattice, John

    2008-01-01

    To visualize what takes place in a chromatography column, enlarge the molecules to human size and expand the columns to keep the ratio of size of molecule to size of column the same. If we were molecules, what would the columns be like? A typical gas chromatography (GC) capillary column would be 50 x 10 [superscript 6] 6 km (31 million mi) long,…

  12. Determination of Thirteen Plasticizers in Food Plastic Packaging Materials by Capillary Column Gas Chromatography%食品包装材料中13种增塑剂的毛细管气相色谱法测定

    Institute of Scientific and Technical Information of China (English)

    马康; 汤福寿; 何雅娟; 刘菲

    2011-01-01

    A capillary column gas chromatographic method was developed for the separation and determination of thirteen plasticizers, including dimethyl phthalate acid ester(DMP), diethyl phthalate acid ester( DEP), dipropyl phthalate acid ester( DnPP), diisobutyl phthalate acid ester( DIBP), dibutyl phthalate acid ester( DBP), diamyl phthalate acid ester( DAP), bisphenol A( BIA), di-n-hexyl phthalate acid ester(DHP), butyl benzyl phthalate acid ester(BBP), di-2-ethylhexyl adipate (DEHA), di(2-ethylhexyl) phthalate acid ester(DEHP), dioctyl phthalate acid ester(DOP) and dinonyl phthalate acid ester(DNP) in plastic packaging materials for foodstuff. The analytes were extracted with hexane from samples by Soxhlet extraction technique, then purified by silica solid phase extraction. Three key factors such as rinse solvent, eluting solvent and eluting volume were optimized. Hexane and toluene ( 1: 1, by volume) were used as rinse solvents, 2 mL ethyl acetate was used as eluting solvent. After filtration, the eluate was determined by gas chromatography with flame ionization detector(GC/FID). The calibration curves of thirteen plasticizers were linear in the range of O. 1 - 1 000 mg/L with detection limits of 0. 005 - 0. 030 mg/L. The spiked recoveries ranged from 90% to 116% with relative standard deviations of 2. 2% -4. 9%. The method was successfully applied in the determination of plasticizers in plastic packaging materials for foodstuff.%建立了索氏提取、固相萃取净化浓缩、毛细管气相色谱法测定塑料食品包装材料中13种增塑剂的方法.优化了固相萃取淋洗剂、洗脱剂和洗脱剂体积等参数.样品经正己烷索氏提取后,用硅胶小柱净化浓缩.以正己烷-甲苯为淋洗剂,2 mL乙酸乙酯为洗脱剂.过滤后的洗脱液用气相色谱仪分析.结果显示,13种增塑剂在0.1~1000 mg/L范围内呈良好线性,检出限为0.005~O.030 mg/L.样品的加标回收率为90%~116%,相对标准偏差为2.2%~4.9%.

  13. Eruption column physics

    Energy Technology Data Exchange (ETDEWEB)

    Valentine, G.A.

    1997-03-01

    In this paper the author focuses on the fluid dynamics of large-scale eruption columns. The dynamics of these columns are rooted in multiphase flow phenomena, so a major part of the paper sets up a foundation on that topic that allows one to quickly assess the inherent assumptions made in various theoretical and experimental approaches. The first part is centered on a set of complex differential equations that describe eruption columns, but the focus is on a general understanding of important physical processes rather than on the mathematics. The author discusses briefly the relative merits and weaknesses of different approaches, emphasizing that the largest advances in understanding are made by combining them. He then focuses on dynamics of steady eruption columns and then on transient phenomena. Finally he briefly reviews the effects of varying behavior of the ambient medium through which an eruption column moves. These final sections will emphasize concepts and a qualitative understanding of eruption dynamics. This paper relies on principles of continuum mechanics and transport processes but does not go into detail on the development of those principles. 36 refs., 36 figs., 3 tabs.

  14. Determination of volatile halohydrocarbons in drinking water by capillary column gas chromatography%毛细管柱气相色谱法测定生活饮用水中挥发性卤代烃

    Institute of Scientific and Technical Information of China (English)

    董玉英; 张瑞雨; 欧利华

    2013-01-01

    Objective: To establish a method for determination of seven volatile halohydrocarbons in drinking water. Methods: The seven volatile halohydrocarbons (chlorofrom, tetrachloromethane, trichloroethylene, bromodi-chloromethane, tetrachloroethylene, dibromochloromethane, bromoform) in drinking water were determined by head-space Gas Chromatography with DB - 624 capillary column. Results: Under the optimal experimental conditions, the recoveries of the seven volatile halohydrocarbons were in the range of 92.5% -102%, the relative standard deviation was between 1.20% ~4.61%, and the determination limit was between 0.01 μg/L ~ 1.00 μg/L. Conclusion: The developed methjod is sensitive, simple, rapid and accurate, and seven volatile halohydrocarbons in drinking water can be determined simultaneously.%目的:建立一种快速、准确测定生活饮用水中7种挥发性卤代烃的方法.方法:采用DB-624毛细管柱、顶空气相色谱法测定生活饮用水中三氯甲烷、四氯化碳、三氯乙烯、二氯一溴甲烷、四氯乙烯、一氯二溴甲烷及三溴甲烷.结果:在所选择的实验条件下,7种挥发性卤代烃的平均回收率在92.5%~102%之间,相对标准偏差(RSD)为1.20% ~4.61%,检出限为0.01 μg/L ~1.00 μg/L.结论:所建立的分析方法灵敏、简便、快速、准确,可同时测定生活饮用水中的7种挥发性卤代烃.

  15. Columns in Clay

    Science.gov (United States)

    Leenhouts, Robin

    2010-01-01

    This article describes a clay project for students studying Greece and Rome. It provides a wonderful way to learn slab construction techniques by making small clay column capitols. With this lesson, students learn architectural vocabulary and history, understand the importance of classical architectural forms and their influence on today's…

  16. Slender CRC Columns

    DEFF Research Database (Denmark)

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    CRC is a high-performance steel fibre reinforced concrete with a typical compressive strength of 150 MPa. Design methods for a number of structural elements have been developed since CRC was invented in 1986, but the current project set out to further investigate the range of columns for which...

  17. Locally Inverse Semigroups with Inverse Transversals

    Institute of Scientific and Technical Information of China (English)

    SHAO Yong; ZHAO Xian Zhong

    2009-01-01

    Let S be a locally inverse semigroup with an inverse transversal S°. In this paper, we construct an amenable partial order on S by an R-cone. Conversely, every amenable partial order on S can be constructed in this way. We give some properties of a locally inverse semigroup with a Clifford transversal. In particular, if S is a locally inverse semigroup with a Clifford transversal, then there is an order-preserving bijection from the set of all amenable partial orders on S to the set of all R-cones of S.

  18. Water Column Variability in Coastal Regions

    Science.gov (United States)

    2016-06-07

    offshore waters of energy, mass, and biota. OBJECTIVES Our objective is to determine the processes that cause water column variations in coastal regions...meteorological conditions (solar radiation, wind velocity, and heat fluxes), (iv) tidal mixing, stratification, water mass variations, (v) runoff from land...air-sea gas exchange and biological activity in these offshore waters. Two papers are being submitted to Limnology and Oceanography on the annual

  19. Using Dividing Wall Columns (DWC) in LNG Production: deviding wall column, double dividing wall column, prefractionator arrangement, Petlyuk column, NGL recovery, distillation

    OpenAIRE

    Ashrafian, Roohollah

    2014-01-01

    The Dividing Wall Columns (DWC) distillation has attracted growing interest for fractionation of multicomponent mixture due to reduction of energy consumption, auxiliary equipment and space within fractionation process. Recent developments of the process show considerable energy saving, up to 30%-40%, compared to conventional fractionation schemes. The objective of this thesis is to introduce DWC configurations, governing equations and applications in LNG and gas processing as well as explana...

  20. DESIGN PARAMETERS ESTIMATION FOR SCALE-UP OF HIGH-PRESSURE BUBBLE-COLUMNS

    NARCIS (Netherlands)

    WILKINSON, PM; SPEK, AP; VANDIERENDONCK, LL

    1992-01-01

    Experiments were carried out in bubble columns for a number of liquids at pressures between 0.1 and 2.0 MPa for two column sizes. Based on the experimental results as well as extensive literature data, the extent of the effect column dimensions have on gas holdup were determined, both at low and hig

  1. Ozone and nitrogen dioxide total columns and vertical distributions at the Italian Antarctic station during 1996-2008

    Science.gov (United States)

    Bortoli, D.; Ravegnani, F.; Giovanelli, G.; Kostadinov, Iv.; Petritoli, A.; Masieri, S.; Premuda, M.; Martins, H. T.; Silva, A. M.

    2009-09-01

    The GASCOD (Gas Analyzer Spectrometer Correlating Optical Differences) has been installed at the 'Mario Zucchelli' Antarctic station since 1996. It measures the zenith sky radiation in the 405-465 nm spectral range in unattended and automatic mode. The application to the spectral data of the DOAS (Differential Optical Absorption Spectroscopy) algorithms coupled with a Radiative Transfer Model (RTM) for the computation of the Air Mass Factor (AMF), allows for the retrieval of the total content of the main absorber in this spectral range, namely nitrogen dioxide (NO2). Moreover, the application of sophisticated inversion schemes to the output of the DOAS program, using the AMF matrix as the kernel of the inversion algorithm, permits the determination of the vertical distribution of the above mentioned compound. The full dataset of the spectral data obtained with GASCOD during the period 1996-2008, was re-analyzed with a modified version of the software tool previously utilized. Even if the spectral range examined with GASCOD is not the most favorable for the ozone total column and vertical profile retrieval, the re-processing of the spectral data allowed for the determination of the total ozone columns (TOC). The uncertainties range from 4% to 8% for ozone and 3% to 6% for NO2. The peculiar features of the seasonal variation of NO2 total columns (i.e. the normal decreasing during the austral fall and the irregular growing towards the summer month) are presented and discussed. The confirmations of the significant declining of the ozone total columns during the 'Ozone Hole' periods (mid-August to mid-October) are reported. The vertical distributions obtained for the preceding atmospheric compounds are shown and examined.

  2. Sparse Matrix Inversion with Scaled Lasso

    CERN Document Server

    Sun, Tingni

    2012-01-01

    We propose a new method of learning a sparse nonnegative-definite target matrix. Our primary example of the target matrix is the inverse of a population covariance matrix or correlation matrix. The algorithm first estimates each column of the matrix by scaled Lasso, a joint estimation of regression coefficients and noise level, and then adjusts the matrix estimator to be symmetric. The procedure is efficient in the sense that the penalty level of the scaled Lasso for each column is completely determined by the data via convex minimization, without using cross-validation. We prove that this method guarantees the fastest proven rate of convergence in the spectrum norm under conditions of weaker form than those in the existing analyses of other $\\ell_1$ algorithms, and has faster guaranteed rate of convergence when the ratio of the $\\ell_1$ and spectrum norms of the target inverse matrix diverges to infinity. A simulation study also demonstrates the competitive performance of the proposed estimator.

  3. Enhanced reductive dechlorination in columns treated with edible oil emulsion

    Science.gov (United States)

    Long, Cameron M.; Borden, Robert C.

    2006-09-01

    The effect of edible oil emulsion treatment on enhanced reductive dechlorination was evaluated in a 14 month laboratory column study. Experimental treatments included: (1) emulsified soybean oil and dilute HCl to inhibit biological activity; (2) emulsified oil only; (3) emulsified oil and anaerobic digester sludge; and (4) continuously feeding soluble substrate. A single application of emulsified oil was effective in generating strongly reducing, anaerobic conditions for over 14 months. PCE was rapidly reduced to cis-DCE in all three live columns. Bioaugmentation with a halorespiring enrichment culture resulted in complete dechlorination of PCE to ethene in the soluble substrate column (yeast extract and lactate). However, an additional treatment with a pulse of yeast extract and bioaugmentation culture was required to stimulate complete dechlorination in the emulsion treated columns. Once the dechlorinating population was established, the emulsion only column degraded PCE from 90-120 μM to below detection with concurrent ethene production in a 33 day contact time. The lower biodegradation rates in the emulsion treated columns compared to the soluble substrate column suggest that emulsified oil barriers may require a somewhat longer contact time for effective treatment. In the HCl inhibited column, partitioning of PCE to the retained oil substantially delayed PCE breakthrough. However, reduction of PCE to more soluble degradation products ( cis-DCE, VC and ethene) greatly reduced the impact of oil-water partitioning in live columns. There was only a small decline in the hydraulic conductivity ( K) of column #1 (low pH + emulsion, Kfinal/ Kinitial = 0.57) and column #2 (live + emulsion, Kfinal/ Kinitial = 0.73) indicating emulsion injection did not result in appreciable clogging of the clayey sand. However, K loss was greater in column #3 (sludge +emulsion, Kfinal/ Kinitial = 0.12) and column #4 (soluble substrate, Kfinal/ Kinitial = 0.03) indicating clogging due

  4. Comparison of the cohesion-adhesion balance approach to colloidal probe atomic force microscopy and the measurement of Hansen partial solubility parameters by inverse gas chromatography for the prediction of dry powder inhalation performance.

    Science.gov (United States)

    Jones, Matthew D; Buckton, Graham

    2016-07-25

    The abilities of the cohesive-adhesive balance approach to atomic force microscopy (AFM) and the measurement of Hansen partial solubility parameters by inverse gas chromatography (IGC) to predict the performance of carrier-based dry powder inhaler (DPI) formulations were compared. Five model drugs (beclometasone dipropionate, budesonide, salbutamol sulphate, terbutaline sulphate and triamcinolone acetonide) and three model carriers (erythritol, α-lactose monohydrate and d-mannitol) were chosen, giving fifteen drug-carrier combinations. Comparison of the AFM and IGC interparticulate adhesion data suggested that they did not produce equivalent results. Comparison of the AFM data with the in vitro fine particle delivery of appropriate DPI formulations normalised to account for particle size differences revealed a previously observed pattern for the AFM measurements, with a slightly cohesive AFM CAB ratio being associated with the highest fine particle fraction. However, no consistent relationship between formulation performance and the IGC data was observed. The results as a whole highlight the complexity of the many interacting variables that can affect the behaviour of DPIs and suggest that the prediction of their performance from a single measurement is unlikely to be successful in every case.

  5. Behavior of Columns During Earthquakes

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The behavior of columns during earthquakes is very important since column failures may lead to additional structural failures and result in total building collapses....

  6. Determination of Two Columns Performance

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    When protein is analyzed by high performance liquid chromatography (HPLC), the selection of column is one of the most important factors. There are four quality control parameters for the column, which are theoretical plates n, capacity facto

  7. NMFS Water Column Sonar Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water column sonar data are an important component of fishery independent surveys, habitat studies and other research. NMFS water column sonar data are archived here.

  8. Inverse anticipating chaos synchronization.

    Science.gov (United States)

    Shahverdiev, E M; Sivaprakasam, S; Shore, K A

    2002-07-01

    We derive conditions for achieving inverse anticipating synchronization where a driven time-delay chaotic system synchronizes to the inverse future state of the driver. The significance of inverse anticipating chaos in delineating synchronization regimes in time-delay systems is elucidated. The concept is extended to cascaded time-delay systems.

  9. Locative Inversion in Cantonese.

    Science.gov (United States)

    Mok, Sui-Sang

    This study investigates the phenomenon of "Locative Inversion" in Cantonese. The term "Locative Inversion" indicates that the locative phrase (LP) syntactic process in Cantonese and the appears at the sentence-initial position and its logical subject occurs postverbally. It is demonstrated that this Locative Inversion is a…

  10. Spray formation: an inverse cascade

    CERN Document Server

    Ling, Yue; Tryggvason, Gretar; zaleski, Stephane

    2015-01-01

    We present a study of droplet formation in a gas-liquid mixing layer using direct numerical simulation. It is seen that two mechanisms compete to generate the droplets: fingering at the tip of the waves and hole formation in the thin liquid sheet. The three dimensional liquid structures are much shorter than the longitudinal wavelength of the instability at the first instant of their formation. As time evolves, the structures evolves to larger and larger scales, in a way similar to the inverse cascade of length scales in droplet impact and impact crown formation.

  11. Why Hexagonal Basalt Columns?

    Science.gov (United States)

    Hofmann, Martin; Anderssohn, Robert; Bahr, Hans-Achim; Weiß, Hans-Jürgen; Nellesen, Jens

    2015-10-09

    Basalt columns with their preferably hexagonal cross sections are a fascinating example of pattern formation by crack propagation. Junctions of three propagating crack faces rearrange such that the initial right angles between them tend to approach 120°, which enables the cracks to form a pattern of regular hexagons. To promote understanding of the path on which the ideal configuration can be reached, two periodically repeatable models are presented here involving linear elastic fracture mechanics and applying the principle of maximum energy release rate. They describe the evolution of the crack pattern as a transition from rectangular start configuration to the hexagonal pattern. This is done analytically and by means of three-dimensional finite element simulation. The latter technique reproduces the curved crack path involved in this transition.

  12. Column: File Cabinet Forensics

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-12-01

    Full Text Available Researchers can spend their time reverse engineering, performing reverse analysis, or making substantive contributions to digital forensics science. Although work in all of these areas is important, it is the scientific breakthroughs that are the most critical for addressing the challenges that we face.Reverse Engineering is the traditional bread-and-butter of digital forensics research. Companies like Microsoft and Apple deliver computational artifacts (operating systems, applications and phones to the commercial market. These artifacts are bought and used by billions. Some have evil intent, and (if society is lucky, the computers end up in the hands of law enforcement. Unfortunately the original vendors rarely provide digital forensics tools that make their systems amenable to analysis by law enforcement. Hence the need for reverse engineering.(see PDF for full column

  13. European Analytical Column

    DEFF Research Database (Denmark)

    Karlberg, B.; Grasserbauer, M.; Andersen, Jens Enevold Thaulov

    2009-01-01

    The European Analytical Column has once more invited a guest columnist to give his views on various matters related to analytical chemistry in Europe. This year, we have invited Professor Manfred Grasserbauer of the Vienna University of Technology to present some of the current challenges...... for European analytical chemistry. During the period 2002–07, Professor Grasserbauer was Director of the Institute for Environment and Sustainability, Joint Research Centre of the European Commission (EC), Ispra, Italy. There is no doubt that many challenges exist at the present time for all of us representing...... a major branch of chemistry, namely analytical chemistry. The global financial crisis is affecting all branches of chemistry, but analytical chemistry, in particular, since our discipline by tradition has many close links to industry. We have already noticed decreased industrial commitment with respect...

  14. SPIRAL CONTACTOR FOR SOLVENT EXTRACTION COLUMN

    Science.gov (United States)

    Cooley, C.R.

    1961-06-13

    The patented extraction apparatus includes a column, perforated plates extending across the column, liquid pulse means connected to the column, and an imperforate spiral ribbon along the length of the column.

  15. Direct Waveform Inversion by Iterative Inverse Propagation

    CERN Document Server

    Schlottmann, R B

    2009-01-01

    Seismic waves are the most sensitive probe of the Earth's interior we have. With the dense data sets available in exploration, images of subsurface structures can be obtained through processes such as migration. Unfortunately, relating these surface recordings to actual Earth properties is non-trivial. Tomographic techniques use only a small amount of the information contained in the full seismogram and result in relatively low resolution images. Other methods use a larger amount of the seismogram but are based on either linearization of the problem, an expensive statistical search over a limited range of models, or both. We present the development of a new approach to full waveform inversion, i.e., inversion which uses the complete seismogram. This new method, which falls under the general category of inverse scattering, is based on a highly non-linear Fredholm integral equation relating the Earth structure to itself and to the recorded seismograms. An iterative solution to this equation is proposed. The res...

  16. Inverse Kinematics using Quaternions

    DEFF Research Database (Denmark)

    Henriksen, Knud; Erleben, Kenny; Engell-Nørregård, Morten

    In this project I describe the status of inverse kinematics research, with the focus firmly on the methods that solve the core problem. An overview of the different methods are presented Three common methods used in inverse kinematics computation have been chosen as subject for closer inspection....... suite, developed in this project and in [4]. Source code developed for this project includes the CCD method , improvements on the BFGS method and Jacobian inverse originally developed in [4]....

  17. Compact electron beam focusing column

    Energy Technology Data Exchange (ETDEWEB)

    Persaud, Arun; Leung, Ka-Ngo; Reijonen, Jani

    2001-07-13

    A novel design for an electron beam focusing column has been developed at LBNL. The design is based on a low-energy spread multicusp plasma source which is used as a cathode for electron beam production. The focusing column is 10 mm in length. The electron beam is focused by means of electrostatic fields. The column is designed for a maximum voltage of 50 kV. Simulations of the electron trajectories have been performed by using the 2-D simulation code IGUN and EGUN. The electron temperature has also been incorporated into the simulations. The electron beam simulations, column design and fabrication will be discussed in this presentation.

  18. Inverse periodic shadowing properties

    CERN Document Server

    Osipov, Alexey V

    2011-01-01

    We consider inverse periodic shadowing properties of discrete dynamical systems generated by diffeomorphisms of closed smooth manifolds. We show that the $C^1$-interior of the set of all diffeomorphisms having so-called inverse periodic shadowing property coincides with the set of $\\Omega$-stable diffeomorphisms. The equivalence of Lipschitz inverse periodic shadowing property and hyperbolicity of the closure of all periodic points is proved. Besides, we prove that the set of all diffeomorphisms that have Lipschitz inverse periodic shadowing property and whose periodic points are dense in the nonwandering set coincides with the set of Axiom A diffeomorphisms.

  19. Cold and Warm Atomic Gas around the Perseus Molecular Cloud. II. The Impact of High Optical Depth on the HI Column Density Distribution and Its Implication for the HI-to-H2 Transition

    CERN Document Server

    Lee, Min-Young; Murray, Claire E; Heiles, Carl; Miller, Jesse

    2015-01-01

    We investigate the impact of high optical depth on the HI surface density (Sigma_HI) saturation observed in the Perseus molecular cloud. We use Arecibo HI emission and absorption measurements obtained toward 26 radio continuum sources to derive the spin temperature and optical depth of individual HI components along each line of sight. The derived properties are used to estimate the correction for high optical depth. We examine two different methods for the correction, Gaussian decomposition and isothermal approximation methods, and find that they are consistent as having the maximum correction factor of ~1.2 likely due to the relatively low optical depth and insignificant contribution from the diffuse radio continuum emission for Perseus. We apply the correction to the HI column density image derived in the optically thin approximation on a pixel-by-pixel basis, and find that the total HI mass increases by only ~10%. Using the corrected HI column density image and far-infrared data from the Improved Reproces...

  20. Rapid methods for inversion of MAXDOAS elevation profiles to surface-associated box concentrations, visibility, and heights: application to analysis of Arctic BrO events

    Directory of Open Access Journals (Sweden)

    D. Donohoue

    2010-11-01

    Full Text Available Multiple Axis Differential Optical Absorption Spectroscopy (MAXDOAS is a remote sensing technique that measures surface-associated trace gas profiles using simple automated instrumentation that requires very low power and is deployable at remote sites. However, the analysis of MAXDOAS data is complex and often cannot be applied rapidly or consistently over long measurement periods. Here we present three transparent methods to analyze MAXDOAS data. The box profile method finds the best trace gas layer height and surface-associated vertical column density (VCD to simultaneously fit oxygen collisional dimer (O4 and trace gas differential slant column density (dSCD observations. The elevated viewing method estimates the surface-associated VCD from observations at high view elevations, such as 10° and 20°. The horizon viewing method estimates the surface concentration of a trace gas by using near-horizon view trace gas and O4 data. We apply these methods to a two-month data set and show that the methods retrieve information 80% of the time and provides a consistent time series. Surface-associated trace gas VCD observations by the elevated viewing method correlate (r2 > 0.93 with the box profile method with slopes within 15% of unity. Surface-associated concentration observations from the horizon viewing method correlate well (r2 > 0.90 with the box profile method and a slope within 4% of unity. Application of these retrieval methods to UV-absorbing trace gases other than BrO is straightforward, and application in other spectral regions is discussed. These methods provide rapid and comprehensive inversions of MAXDOAS spectral data that are useful during field campaigns, as well as, verification of more complex (e.g. optimal estimate inversion methods.

  1. An Axial Dispersion Model for Evaporating Bubble Column Reactor

    Institute of Scientific and Technical Information of China (English)

    谢刚; 李希

    2004-01-01

    Evaporating bubble column reactor (EBCR) is a kind of aerated reactor in which the reaction heat is removed by the evaporation of volatile reaction mixture. In this paper, a mathematical model that accounts for the gas-liquid exothermic reaction and axial dispersions of both gas and liquid phase is employed to study the performance of EBCR for the process of p-xylene(PX) oxidation. The computational results show that there are remarkable concentration and temperature gradients in EBCR for high ratio of height to diameter (H/DT). The temperature is lower at the bottom of column and higher at the top, due to rapid evaporation induced by the feed gas near the bottom. The concentration profiles in the gas phase are more nonuniform than those (except PX) in the liquid phase, which causes more solvent burning consumption at high H/DT ratio. For p-xylene oxidation, theo ptimal H/DT is around 5.

  2. Dynamical inverse problems

    CERN Document Server

    Gladwell, Graham ML

    2011-01-01

    The papers in this volume present an overview of the general aspects and practical applications of dynamic inverse methods, through the interaction of several topics, ranging from classical and advanced inverse problems in vibration, isospectral systems, dynamic methods for structural identification, active vibration control and damage detection, imaging shear stiffness in biological tissues, wave propagation, to computational and experimental aspects relevant for engineering problems.

  3. Practical design of stepped columns

    NARCIS (Netherlands)

    Girao Coelho, A.M.; Simao, P.D.; Bijlaard, F.S.K.

    2012-01-01

    This paper deals with buckling aspects of the design of stepped columns in heavy mill buildings. In these structures, columns have to carry significant axial loads that usually act eccentrically and strength reducing bending moments due to lateral loads. A simple physical model for buckling behaviou

  4. An Undergraduate Column Chromatography Experiment.

    Science.gov (United States)

    Danot, M.; And Others

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for an experiment designed to introduce undergraduate students to the theoretical and technical aspects of column chromatography. The experiment can also be shortened to serve as a demonstration of the column chromatography technique. (JN)

  5. Inverse Symmetric Inflationary Attractors

    CERN Document Server

    Odintsov, S D

    2016-01-01

    We present a class of inflationary potentials which are invariant under a special symmetry, which depends on the parameters of the models. As we show, in certain limiting cases, the inverse symmetric potentials are qualitatively similar to the $\\alpha$-attractors models, since the resulting observational indices are identical. However, there are some quantitative differences which we discuss in some detail. As we show, some inverse symmetric models always yield results compatible with observations, but this strongly depends on the asymptotic form of the potential at large $e$-folding numbers. In fact when the limiting functional form is identical to the one corresponding to the $\\alpha$-attractors models, the compatibility with the observations is guaranteed. Also we find the relation of the inverse symmetric models with the Starobinsky model and we highlight the differences. In addition, an alternative inverse symmetric model is studied and as we show, not all the inverse symmetric models are viable. Moreove...

  6. 0-Semidistributive Inverse Semigroups

    Institute of Scientific and Technical Information of China (English)

    田振际

    2004-01-01

    @@ For an inverse semigroup S, the set L(S) of all inverse subsemigroups (including the empty set) of S forms a lattice with respect to intersection denoted as usual by ∩ and union, where the union is the inverse subsemigroup generated by inverse subsemigroups A, B of S. The set LF(S) of all full inverse subsemigroups of S forms a complete sublattice of L(S), with Es as zero element (Es is the set of all idempotent of S)(see [3,5,6]). Note, that if S a group, then LF(S)=L(S), its lattice of all subgroups of S. If S = G0 is a group with adjoined zero, then clearly LF(S) ≌ L(G).

  7. Optimization of bubble column performance for nanoparticle collection.

    Science.gov (United States)

    Cadavid-Rodriguez, M C; Charvet, A; Bemer, D; Thomas, D

    2014-04-30

    Fibrous media embody the most effective and widely used method of separating ultrafine particles from a carrier fluid. The main problem associated with them is filter clogging, which induces an increasingly marked pressure drop with time and thus imposes regular media cleaning or replacement. This context has prompted the idea of investigating bubble columns, which operate at constant pressure drop, as alternatives to fibrous filters. This study examines the influence of different operating conditions, such as liquid height, air flow rate, bubble size and presence of granular beds on ultrafine particle collection. Experimental results show that bubble columns are characterised by high collection efficiency, when they feature a large liquid height and small diameter bubbling orifices, while their efficiencies remain lower than those of fibrous filters. Gas velocity does not greatly influence collection efficiency, but the inclusion of a granular bed, composed of beads, increases the bubble residence time in the column, thereby increasing the column collection efficiency.

  8. Optimized determination of trace jet fuel volatile organic compounds in human blood using in-field liquid-liquid extraction with subsequent laboratory gas chromatographic-mass spectrometric analysis and on-column large-volume injection.

    Science.gov (United States)

    Liu, S; Pleil, J D

    2001-03-05

    A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing techniques, and a new on-column large-volume injection method for GC-MS analysis. With the optimized methods, the extraction efficiency was improved by 4.3 to 20.1 times and the detection sensitivity increased up to 660 times over the standard method. Typical detection limits in the parts-per-trillion (ppt) level range were achieved for all monitored JP-8 constituents; this is sufficient for assessing human fuels exposures at trace environmental levels as well as occupational exposure levels. The sample extractions are performed in the field and only solvent extracts need to be shipped to the laboratory. The method is implemented with standard biological laboratory equipment and a modest bench-top GC-MS system.

  9. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  10. Numerical Simulation and Analysis of Gas Flow Field in Serrated Valve Column%齿边浮阀塔内气相流场的数值模拟和分析

    Institute of Scientific and Technical Information of China (English)

    王良华; 崔党剑; 姚克俭

    2008-01-01

    A three-dimensional computational fluid dynamics (CFD) model for gas flow through a seffated valve tray was presented.The flow field.as well as the dry-pressure drop of the valve under the full-opening condition was simulated based on the proposed model by using FLUENT 6.0 software.Compared with t11e values of dry-pressure drop in difierent tUrbulent models.the simulated results using RNG κ-ε model are in reasonable agreement with experimental data.indicating that RNG κ-ε modeliS suitable in simulating gas flow through the serrated valve tray.Then the CFD model combining RNG κ-εmodel was used to study the three-dimensional gas flow through the considered serfated valve trav.The simulated results showed that various eddies existed on the serrated valve tray,and both the eddy and the non-eddy areas were nearly equal.The existence of addendum Can decrease the eddy area caused by gas passing through the lateral outlet slots.The size of eddies Call be reduced by optimizing the distance between valyes.

  11. Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography – tandem mass spectrometry

    Science.gov (United States)

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...

  12. Inversion for sediment geoacoustic properties at the New England Bight

    Science.gov (United States)

    Potty, Gopu R.; Miller, James H.; Lynch, James F.

    2003-10-01

    This article discusses inversions for bottom geoacoustic properties using broadband acoustic signals obtained from explosive sources. Two different inversion schemes for estimating the compressional wave speeds and attenuation are presented in this paper. In addition to these sediment parameters, source-receiver range is also estimated using the arrival time data. The experimental data used for the inversions are SUS charge explosions acquired on a vertical hydrophone array during the Shelf Break Primer Experiment conducted south of New England in the Middle Atlantic Bight in August 1996. The modal arrival times are extracted using a wavelet analysis. In the first inversion scheme, arrival times corresponding to various modes and frequencies from 10 to 200 Hz are used for the inversion of compressional wave speeds. A hybrid inversion scheme based on a genetic algorithm (GA) is used for the inversion. In an earlier study, Potty et al. [J. Acoust. Soc. Am. 108(3), 973-986 (2000)] have used this hybrid scheme in a range-independent environment. In the present study results of range-dependent inversions are presented. The sound speeds in the water column and bathymetry are assumed range dependent, whereas the sediment compressional wave speeds are assumed range independent. The variations in the sound speeds in the water column are represented using empirical orthogonal functions (EOFs). The replica fields corresponding to the unknown parameters were constructed using adiabatic theory. In the second inversion scheme, modal attenuation coefficients are calculated using modal amplitude ratios. The ratios of the modal amplitudes are also calculated using time-frequency diagrams. A GA-based inversion scheme is used for this search. Finally, as a cross check, the computed compressional wave speeds along with the modal arrival times were used to estimate the source-receiver range. The inverted sediment properties and ranges are seen to compare well with in situ measurements

  13. 固相萃取-双柱气相色谱法测定水中多种有机磷农药残留%Determination of multiple organophosphorous pesticide residues in water by dual-column gas chromatography coupled with solid phase extraction

    Institute of Scientific and Technical Information of China (English)

    陈烨; 许秀艳; 吕怡兵; 滕恩江; 邢冠华; 王超

    2011-01-01

    针对单一气相色谱柱定性分析易出现假阳性误判的情况,采用固相萃取-气相色谱双柱技术测定环境水体中多种有机磷农药的残留量.水样中的有机磷农药通过HLB固相萃取小柱富集,经洗脱浓缩后,用DB-35MS和HP-5毛细管气相色谱柱、火焰光度检测器测定.方法的平均加标回收率为86.1%~118%,相对标准偏差为3.2%~6.8%,最低检出限为20~40 ng/L,可满足环境水体中痕量有机磷农药残留的分析需要.%To avoid the case of false positive when analyzing by single column, the dual-column gas chromatography coupled with solid phase extraction was applied to the multi -residue determination of organophosphorous pesticides in environmental water. The organophosphorous pesticides were extracted from water with HLB solid phase extraction cartridges and then eluted. After concentrated, the eluents were detected by GC-FPD with DB-35MS and HP-5 capillary columns. The average recoveries of 5 replicates for analytes ranged from 86.1% to 118%, with relative standard deviations between 3.2% and 6.8%. And the method detection limits were within the range of 20 ng/L to 40 ng/L. The results showed that the proposed method is suitable for the determination of trace amounts of multiple organophosphorous pesticide residues in environmental water.

  14. Approximate inverse preconditioners for general sparse matrices

    Energy Technology Data Exchange (ETDEWEB)

    Chow, E.; Saad, Y. [Univ. of Minnesota, Minneapolis, MN (United States)

    1994-12-31

    Preconditioned Krylov subspace methods are often very efficient in solving sparse linear matrices that arise from the discretization of elliptic partial differential equations. However, for general sparse indifinite matrices, the usual ILU preconditioners fail, often because of the fact that the resulting factors L and U give rise to unstable forward and backward sweeps. In such cases, alternative preconditioners based on approximate inverses may be attractive. We are currently developing a number of such preconditioners based on iterating on each column to get the approximate inverse. For this approach to be efficient, the iteration must be done in sparse mode, i.e., we must use sparse-matrix by sparse-vector type operatoins. We will discuss a few options and compare their performance on standard problems from the Harwell-Boeing collection.

  15. How well does wind speed predict air-sea gas transfer in the sea ice zone? A synthesis of radon deficit profiles in the upper water column of the Arctic Ocean

    Science.gov (United States)

    Loose, B.; Kelly, R. P.; Bigdeli, A.; Williams, W.; Krishfield, R.; Rutgers van der Loeff, M.; Moran, S. B.

    2017-05-01

    We present 34 profiles of radon-deficit from the ice-ocean boundary layer of the Beaufort Sea. Including these 34, there are presently 58 published radon-deficit estimates of air-sea gas transfer velocity (k) in the Arctic Ocean; 52 of these estimates were derived from water covered by 10% sea ice or more. The average value of k collected since 2011 is 4.0 ± 1.2 m d-1. This exceeds the quadratic wind speed prediction of weighted kws = 2.85 m d-1 with mean-weighted wind speed of 6.4 m s-1. We show how ice cover changes the mixed-layer radon budget, and yields an "effective gas transfer velocity." We use these 58 estimates to statistically evaluate the suitability of a wind speed parameterization for k, when the ocean surface is ice covered. Whereas the six profiles taken from the open ocean indicate a statistically good fit to wind speed parameterizations, the same parameterizations could not reproduce k from the sea ice zone. We conclude that techniques for estimating k in the open ocean cannot be similarly applied to determine k in the presence of sea ice. The magnitude of k through gaps in the ice may reach high values as ice cover increases, possibly as a result of focused turbulence dissipation at openings in the free surface. These 58 profiles are presently the most complete set of estimates of k across seasons and variable ice cover; as dissolved tracer budgets they reflect air-sea gas exchange with no impact from air-ice gas exchange.

  16. CENTRAL COMPOSITE STATISTICAL ASSESSMENT OF GAS-LIQUID MASS TR ANSFER IN SLURRY BUBBLE COLUMN REACTOR%中心复合设计法研究浆液床反应器的气液传质特性

    Institute of Scientific and Technical Information of China (English)

    门卓武; Arsam,B

    2000-01-01

    Central composite statistical design approach was employ ed to study the effects of pressure (P),superficial gas velocity (UG) and solid concentration (Cv) on the volumetric gas-liquid mass transfer c oefficient (kLa).The kLa values were found to increase with the increase of superficial gas velocity and pressure,on the other hand,it decre ased with the increase of solid concentration.In the pressure range of 0.1~1.5 MPa,the equilibrium solubility of CH4 appears to follow Henry's Law.%采用中心复合设计法研究系统压力(P)、气体表观气速(UG)以及固体颗粒体积浓度(Cv)对浆液床中体积气液传质系数(kLa)的影响。在实验中发现,体积气液传质系数随系统压力和气体表观气速的增加而增加,当增加固体颗粒体积浓度时反而下降。在0.1~1.5 MPa的压力范围内,甲烷的饱和溶解度遵守亨利定律。

  17. Numerical models of Plinian eruption columns and pyroclastic flows

    Science.gov (United States)

    Valentine, Greg A.; Wohletz, Kenneth H.

    1989-02-01

    Numerical simulations of physical processes governing the large-scale dynamics of Plinian eruption columns reveal conditions contributing to column collapse and emplacement of pyroclastic flows. The simulations are based on numerical solution of the time-dependent, two-phase, compressible Navier-Stokes equations for jets in a gravitational field. This modeling effort is directed toward studying the steady discharge phase of eruptions in contrast to our previous models of the initial, unsteady blast phase. Analysis of 51 eruption models covers a wide range of vent exit pressures, inertial and buoyancy driving forces, and coupling of energy and momentum between gas and pyroclasts. Consideration of three dimensionless groups (Richardson and Rouse numbers and thermogravitational parameter) facilitates this analysis and defines conditions leading to column collapse. For eruptions with similar particle size characteristics, exit pressure ratios are also very important in determining column behavior; column behavior is much more sensitive to exit pressure ratio than to the density ratio between the column and the atmosphere. Model eruption columns with exit pressures exceeding atmospheric pressure have diamond-shaped patterns at their bases with internal dynamics that correspond closely to observations of overpressured jets in laboratory experiments. Collapsing fountains form pyroclastic flows that consist of low-concentration fronts, relatively thick heads, vortex development along the top surfaces, and rising clouds of buoyant ash. The presence of coarse-grained proximal deposits primarily reflects tephra size sorting within the eruption column before collapse, as opposed to that which occurs during lateral transport of the material in pyroclastic flows. The dynamics and particle behavior in the proximal zone around collapsing eruption columns is examined; the modeling indicates that flow within a few kilometers of a vent will be at its highest particle concentration

  18. Comparison of SX of uranium using mixer settler and columns

    Energy Technology Data Exchange (ETDEWEB)

    Grinbaum, B., E-mail: baruchgr@bateman.co.il [Bateman Advanced Technologies, Yokneam (Israel); Kotze, M. [Mintek, Randburg (South Africa); Buchalter, E. [Bateman Advanced Technologies, Yokneam (Israel)

    2010-07-01

    Two types of equipment are used in the industry for solvent extraction (SX) of U: mixer-settlers (MS) and columns. Currently the only published type of columns applied in U SX is the Bateman Pulsed Columns (BPC). These columns have been applied for extraction of U for more than 13 years in Olympic Dam plant in Australia and in recent years were also introduced to additional plants in Australia and South Africa. Other plants are using MS of various types. The columns are currently used in the extraction battery only. For stripping and scrubbing only MS are currently used. Although pilot tests prove that the pH gradient required in the stripping may be successfully obtained in the BPC, they have not yet been applied in the industry. The paper compares the extraction and stripping in both types of equipment, regarding the capital cost, operating costs and operating conditions. The capital cost of the BPC is lower by 33-40%, depending on the size of the plant and the quality of the ore. The operating costs with the BPC are slightly lower, due to smaller losses of solvent. From operating point of view the BPC has the ability to recover from phase inversion and precipitation of yellow cake without the need to shut down the plant, if the problem is addressed within a few minutes. (author)

  19. A new approach for inversion of large random matrices in massive MIMO systems.

    Directory of Open Access Journals (Sweden)

    Muhammad Ali Raza Anjum

    Full Text Available We report a novel approach for inversion of large random matrices in massive Multiple-Input Multiple Output (MIMO systems. It is based on the concept of inverse vectors in which an inverse vector is defined for each column of the principal matrix. Such an inverse vector has to satisfy two constraints. Firstly, it has to be in the null-space of all the remaining columns. We call it the null-space problem. Secondly, it has to form a projection of value equal to one in the direction of selected column. We term it as the normalization problem. The process essentially decomposes the inversion problem and distributes it over columns. Each column can be thought of as a node in the network or a particle in a swarm seeking its own solution, the inverse vector, which lightens the computational load on it. Another benefit of this approach is its applicability to all three cases pertaining to a linear system: the fully-determined, the over-determined, and the under-determined case. It eliminates the need of forming the generalized inverse for the last two cases by providing a new way to solve the least squares problem and the Moore and Penrose's pseudoinverse problem. The approach makes no assumption regarding the size, structure or sparsity of the matrix. This makes it fully applicable to much in vogue large random matrices arising in massive MIMO systems. Also, the null-space problem opens the door for a plethora of methods available in literature for null-space computation to enter the realm of matrix inversion. There is even a flexibility of finding an exact or approximate inverse depending on the null-space method employed. We employ the Householder's null-space method for exact solution and present a complete exposition of the new approach. A detailed comparison with well-established matrix inversion methods in literature is also given.

  20. A new approach for inversion of large random matrices in massive MIMO systems.

    Science.gov (United States)

    Anjum, Muhammad Ali Raza; Ahmed, Muhammad Mansoor

    2014-01-01

    We report a novel approach for inversion of large random matrices in massive Multiple-Input Multiple Output (MIMO) systems. It is based on the concept of inverse vectors in which an inverse vector is defined for each column of the principal matrix. Such an inverse vector has to satisfy two constraints. Firstly, it has to be in the null-space of all the remaining columns. We call it the null-space problem. Secondly, it has to form a projection of value equal to one in the direction of selected column. We term it as the normalization problem. The process essentially decomposes the inversion problem and distributes it over columns. Each column can be thought of as a node in the network or a particle in a swarm seeking its own solution, the inverse vector, which lightens the computational load on it. Another benefit of this approach is its applicability to all three cases pertaining to a linear system: the fully-determined, the over-determined, and the under-determined case. It eliminates the need of forming the generalized inverse for the last two cases by providing a new way to solve the least squares problem and the Moore and Penrose's pseudoinverse problem. The approach makes no assumption regarding the size, structure or sparsity of the matrix. This makes it fully applicable to much in vogue large random matrices arising in massive MIMO systems. Also, the null-space problem opens the door for a plethora of methods available in literature for null-space computation to enter the realm of matrix inversion. There is even a flexibility of finding an exact or approximate inverse depending on the null-space method employed. We employ the Householder's null-space method for exact solution and present a complete exposition of the new approach. A detailed comparison with well-established matrix inversion methods in literature is also given.

  1. On Generalized Inverse Transversals

    Institute of Scientific and Technical Information of China (English)

    Rong Hua ZHANG; Shou Feng WANG

    2008-01-01

    Let S be a regular semigroup,S° an inverse subsemigroup of S.S° is called a generalized inverse transversal of S,if V(x) ∩N S°≠φ.In this paper,some properties of this kind of semigroups are discussed.In particular,a construction theorem is obtained which contains some recent results in the literature as its special cases.

  2. Water Column Sonar Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The collection and analysis of water column sonar data is a relatively new avenue of research into the marine environment. Primary uses include assessing biological...

  3. The inverse electroencephalography pipeline

    Science.gov (United States)

    Weinstein, David Michael

    The inverse electroencephalography (EEG) problem is defined as determining which regions of the brain are active based on remote measurements recorded with scalp EEG electrodes. An accurate solution to this problem would benefit both fundamental neuroscience research and clinical neuroscience applications. However, constructing accurate patient-specific inverse EEG solutions requires complex modeling, simulation, and visualization algorithms, and to date only a few systems have been developed that provide such capabilities. In this dissertation, a computational system for generating and investigating patient-specific inverse EEG solutions is introduced, and the requirements for each stage of this Inverse EEG Pipeline are defined and discussed. While the requirements of many of the stages are satisfied with existing algorithms, others have motivated research into novel modeling and simulation methods. The principal technical results of this work include novel surface-based volume modeling techniques, an efficient construction for the EEG lead field, and the Open Source release of the Inverse EEG Pipeline software for use by the bioelectric field research community. In this work, the Inverse EEG Pipeline is applied to three research problems in neurology: comparing focal and distributed source imaging algorithms; separating measurements into independent activation components for multifocal epilepsy; and localizing the cortical activity that produces the P300 effect in schizophrenia.

  4. Generalized emissivity inverse problem.

    Science.gov (United States)

    Ming, DengMing; Wen, Tao; Dai, XianXi; Dai, JiXin; Evenson, William E

    2002-04-01

    Inverse problems have recently drawn considerable attention from the physics community due to of potential widespread applications [K. Chadan and P. C. Sabatier, Inverse Problems in Quantum Scattering Theory, 2nd ed. (Springer Verlag, Berlin, 1989)]. An inverse emissivity problem that determines the emissivity g(nu) from measurements of only the total radiated power J(T) has recently been studied [Tao Wen, DengMing Ming, Xianxi Dai, Jixin Dai, and William E. Evenson, Phys. Rev. E 63, 045601(R) (2001)]. In this paper, a new type of generalized emissivity and transmissivity inverse (GETI) problem is proposed. The present problem differs from our previous work on inverse problems by allowing the unknown (emissivity) function g(nu) to be temperature dependent as well as frequency dependent. Based on published experimental information, we have developed an exact solution formula for this GETI problem. A universal function set suggested for numerical calculation is shown to be robust, making this inversion method practical and convenient for realistic calculations.

  5. Precipitation of CuS and ZnS in a bubble column reactor

    NARCIS (Netherlands)

    Al-Tarazi, M.; Heesink, A. Bert M.; Versteeg, G. F.; Azzam, M. O. J.; Azzam, K.

    2005-01-01

    This work presents an experimental study into the precipitation of CuS and ZnS in a semibatch-wise operated bubble column. First the applied bubble column was characterized with respect to mass transfer phenomena. The influences of ionic strength and superficial gas velocity on volumetric mass trans

  6. Effect of Solid Loading on Carbon Dioxide Absorptionin Bubble Column

    Directory of Open Access Journals (Sweden)

    Alyaa Khadhier Mageed

    2011-01-01

    Full Text Available In the present work experiments were conducted to study the effect of solid loading (1,5 and 9 vol.% on the enhancement of carbon dioxide absorption in bubble column at various volumetric gas flow rate (0.75, 1 and 1.5 m3/h and absorbent concentration (caustic soda( 0.1,0.5 and 1 M . Activated carbon and alumina oxide (Al2O3 are used as solid particles. The Danckwerts method was used to calculate interfacial area and individual mass transfer coefficients during absorption of carbon dioxide in a bubble column. The results show that the absorption rate was increased with increasing volumetric gas flow rate, caustic soda concentration and solid loading. Mass transfer coefficient and interfacial area were increased with increasing volumetric gas flow rate, and solid loading.

  7. Characterization of surface properties of polybutadiene rubber by inverse gas chromatography%反相气相色谱法表征聚丁二烯橡胶的表面性质

    Institute of Scientific and Technical Information of China (English)

    王强; 马凤云; 田华; 宋玉萍; 徐文清; 唐军

    2011-01-01

    Inverse gas chromatography was applied to the characterization of the surface properties of polybutadiene rubber (PBR). Four n-alkanes (C6, C7, C8 and C9-alkanes) were chosen as the apolar probes to characterize the dispersive component of surface free energy.Dichloromethane, trichloromethane, acetone, ethyl acetate, diethylether and tetrahydrofuran were chosen as the polar probes to detect the Lewis acid-base parameters. It was found that the dispersive components of surface free energy were 47.07, 46.46, 45.85, 45.60 and 45.09 mJ/m2 at 303, 313, 323, 333 and 343 K, respectively. The results showed that the surface free energy decreased linearly with the increase of temperature. The Lewise acidic number Ka of PBR was 0.34, and the basic number Kb was 1.77. The fact Kb/Ka > 1 means that the surface of PBR was amphoteric with dominant basic character and the total ability of the surface to acid-base interactions was 2.11. The free energies of adsorption - ΔGa s and - ΔHa 8 by Lewis acid-base interaction were also figured out.%采用反相气相色谱技术测定了聚丁二烯橡胶的表面性质.以正己烷、正庚烷、正辛烷、正壬烷作为非极性探针测定其表面色散自由能,以二氯甲烷、三氯甲烷、丙酮、乙酸乙酯、乙醚和四氢呋喃作为极性探针测定其路易斯酸碱常数.经计算得出聚丁二烯橡胶在303、313、323、333和343 K的表面色散自由能分别为47.07、46.46、45.85、45.60和45.09 mJ/m.结果表明,聚丁二烯橡胶表面色散自由能随着温度的升高呈线性降低,路易斯酸常数K,为0.34,碱常数K为1.77,总酸碱作用能力2.11,该聚合物为弱碱性Lewis两性聚合物材料.此外还计算出聚丁二烯橡胶的酸碱作用吸附自由能(-△G)和吸附焓(-△H).

  8. On column density thresholds and the star formation rate

    CERN Document Server

    Clark, Paul C

    2013-01-01

    We present the results of a numerical study designed to address the question of whether there is a column density threshold for star formation within molecular clouds. We have simulated a large number of different clouds, with volume and column densities spanning a wide range of different values, using a state-of-the-art model for the coupled chemical, thermal and dynamical evolution of the gas. We show that for low-mass clouds, around 1000 solar masses and below, star formation is only possible if the mean cloud column density exceeds 10^21 cm^-2. In more massive clouds, the required mean column density is a factor of a few lower. We demonstrate that this behaviour is well-described by a simple Jeans mass argument: clouds must contain multiple Jeans masses in order to form stars, and hence star-forming clouds cannot have arbitrarily low column densities. We have also examined the question of whether there is a column density threshold for the regions within clouds where star formation occurs. We show that th...

  9. Power Plant Emission Monitoring in Munich Using Differential Column Measurements

    Science.gov (United States)

    Chen, Jia; Nguyen, Hai; Toja-Silva, Francisco; Heinle, Ludwig; Hase, Frank; Butz, André

    2017-04-01

    Differential column measurements using compact Fourier transform spectrometers (EM27/SUN) have shown to be an effective method to determine the greenhouse gas emissions. Citywide measurement campaigns were carried out in Boston, Indianapolis, San Francisco, etc., focusing on city (e.g. emissions from natural gas infrastructure) and local sources. We are particularly working on validating this novel method for attributing and quantifying local emission sources. Optimal strategies are developed for measuring in different seasons with various sun elevations. We have deployed two spectrometers to monitor the CO2 and CH4 emission rates (kg s-1) of a natural gas fired combined heat-and-power plant in Munich, Germany (Heizkraftwerk Süd). We placed our spectrometers in the vicinity (differential column measurements for determining power plant emissions and explore their sensitivities to meteorological and model parameters. In addition, we present measurement strategies and experimental design criteria for different meteorological conditions and time of the year, including winter when the sun elevation is low and the column inclination becomes very important. Differential column measurements using compact spectrometers are shown to be a reliable method to monitor power plant emissions.

  10. Bubble Size Distribution in a Vibrating Bubble Column

    Science.gov (United States)

    Mohagheghian, Shahrouz; Wilson, Trevor; Valenzuela, Bret; Hinds, Tyler; Moseni, Kevin; Elbing, Brian

    2016-11-01

    While vibrating bubble columns have increased the mass transfer between phases, a universal scaling law remains elusive. Attempts to predict mass transfer rates in large industrial scale applications by extrapolating laboratory scale models have failed. In a stationary bubble column, mass transfer is a function of phase interfacial area (PIA), while PIA is determined based on the bubble size distribution (BSD). On the other hand, BSD is influenced by the injection characteristics and liquid phase dynamics and properties. Vibration modifies the BSD by impacting the gas and gas-liquid dynamics. This work uses a vibrating cylindrical bubble column to investigate the effect of gas injection and vibration characteristics on the BSD. The bubble column has a 10 cm diameter and was filled with water to a depth of 90 cm above the tip of the orifice tube injector. BSD was measured using high-speed imaging to determine the projected area of individual bubbles, which the nominal bubble diameter was then calculated assuming spherical bubbles. The BSD dependence on the distance from the injector, injector design (1.6 and 0.8 mm ID), air flow rates (0.5 to 5 lit/min), and vibration conditions (stationary and vibration conditions varying amplitude and frequency) will be presented. In addition to mean data, higher order statistics will also be provided.

  11. Long-term analysis of carbon dioxide and methane column-averaged mole fractions retrieved from SCIAMACHY

    Science.gov (United States)

    Schneising, Oliver; Buchwitz, Michael; Reuter, Maximilian; Heymann, Jens; Bovensmann, Heinrich; Burrows, John P.

    2010-05-01

    Carbon dioxide (CO2) and methane (CH4) are the two most important anthropogenic greenhouse gases contributing to climate change. Despite their importance our knowledge about their variable natural and anthropogenic sources and sinks has significant gaps. Satellite observations can add important global scale information on greenhouse gas sources and sinks provided the data are accurate and precise enough and are sensitive to the lowest atmospheric layers where the variability is largest. High sensitivity to near-surface greenhouse gas concentration changes can be achieved using reflected solar radiation in the near-infrared/shortwave-infrared (NIR/SWIR) spectral region. SCIAMACHY onboard ENVISAT (launch 2002) was the first and is now besides TANSO onboard GOSAT (launch 2009) the only satellite instrument currently in space covering important absorption bands of both gases in this spectral range. Global SCIAMACHY nadir observations from the time period 2003-2009 have been used to retrieve carbon dioxide and methane column-averaged mole fractions (which are the quantities needed for inverse modelling to get information on the sources and sinks) constituting seven years of greenhouse gas information derived from European EO data and offering temporal overlap with GOSAT. These new improved WFM-DOAS multi-year global data sets extending afore existing retrievals will be presented and discussed including an analysis of the long-term characteristics and comparison of the retrieved mole fractions with independent data, e.g., a first analysis of how the SCIAMACHY results compare with GOSAT retrievals for the overlapping time period.

  12. Determination of ten steroid hormones in animal waste manure and agricultural soil using inverse and integrated clean-up pressurized liquid extraction and gas chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, Martin; Krogh, Kristine A; Halling-Sørensen, Bent

    2011-01-01

    ... Martin Hansen , Kristine A. Krogh , Bent Halling ... in a 22 mL PLE cell : firstly by flushing the sample with heptane to remove unwanted matrix components (inverse- PLE , i- PLE ) and secondly, performing internal clean-up (ic- PLE ) and eluting the steroid hormones by attaching an ...

  13. Radiotracer Imaging of Sediment Columns

    Science.gov (United States)

    Moses, W. W.; O'Neil, J. P.; Boutchko, R.; Nico, P. S.; Druhan, J. L.; Vandehey, N. T.

    2010-12-01

    Nuclear medical PET and SPECT cameras routinely image radioactivity concentration of gamma ray emitting isotopes (PET - 511 keV; SPECT - 75-300 keV). We have used nuclear medical imaging technology to study contaminant transport in sediment columns. Specifically, we use Tc-99m (T1/2 = 6 h, Eγ = 140 keV) and a SPECT camera to image the bacteria mediated reduction of pertechnetate, [Tc(VII)O4]- + Fe(II) → Tc(IV)O2 + Fe(III). A 45 mL bolus of Tc-99m (32 mCi) labeled sodium pertechnetate was infused into a column (35cm x 10cm Ø) containing uranium-contaminated subsurface sediment from the Rifle, CO site. A flow rate of 1.25 ml/min of artificial groundwater was maintained in the column. Using a GE Millennium VG camera, we imaged the column for 12 hours, acquiring 44 frames. As the microbes in the sediment were inactive, we expected most of the iron to be Fe(III). The images were consistent with this hypothesis, and the Tc-99m pertechnetate acted like a conservative tracer. Virtually no binding of the Tc-99m was observed, and while the bolus of activity propagated fairly uniformly through the column, some inhomogeneity attributed to sediment packing was observed. We expect that after augmentation by acetate, the bacteria will metabolically reduce Fe(III) to Fe(II), leading to significant Tc-99m binding. Imaging sediment columns using nuclear medicine techniques has many attractive features. Trace quantities of the radiolabeled compounds are used (micro- to nano- molar) and the half-lives of many of these tracers are short (Image of Tc-99m distribution in a column containing Rifle sediment at four times.

  14. Structural variation of solid core and thickness of porous shell of 1.7 μm core-shell silica particles on chromatographic performance: narrow bore columns.

    Science.gov (United States)

    Omamogho, Jesse O; Hanrahan, John P; Tobin, Joe; Glennon, Jeremy D

    2011-04-15

    Chromatographic and mass transfer kinetic properties of three narrow bore columns (2.1×50 mm) packed with new core-shell 1.7 μm EIROSHELL™-C(18) (EiS-C(18)) particles have been studied. The particles in each column varied in the solid-core to shell particle size ratio (ρ), of 0.59, 0.71 and 0.82, with a porous silica shell thickness of 350, 250 and 150 nm respectively. Scanning and transmission electron microscopy (SEM and TEM), Coulter counter analysis, gas pycnometry, nitrogen sorption analysis and inverse size exclusion chromatography (ISEC) elucidated the physical properties of these materials. The porosity measurement of the packed HILIC and C(18) modified phases provided the means to estimate the phase ratios of the three different shell columns (EiS-150-C(18), EiS-250-C(18) and EiS-350-C(18)). The dependence of the chromatographic performance to the volume fraction of the porous shell was observed for all three columns. The naphtho[2,3-a]pyrene retention factor of k'∼10 on the three EiS-C(18s) employed to obtain the height equivalents to theoretical plates (HETPs) data were achieved by varying the mobile phase compositions and applying the Wilke and Chang relationship to obtain a parallel reduced linear velocity. The Knox fit model gave the coefficient of the reduce HETPs for the three EiS-C(18s). The reduced plate height minimum h(min)=1.9 was achieved for the EiS-150-C(18) column, and generated an efficiency of over 350,000 N/m and h(min)=2.5 equivalent to an efficiency of 200,000 N/m for the EiS-350-C(18) column. The efficiency loss of the EiS-C18 column emanating from the system extra-column volume was discussed with respect to the porous shell thickness.

  15. A comparison study of commercially-available column flotation technologies

    Energy Technology Data Exchange (ETDEWEB)

    Honaker, R.Q.; Mohanty, M.K.; Paul, B.C. [Southern Illinois Univ., Carbondale, IL (United States). Dept. of Mining Engineering; Ho, K. [Illinois Clean Coal Inst., Carterville, IL (United States)

    1994-12-31

    A direct comparison of three commercially-available column flotation technologies, i.e., Jameson Cell, Microcel, and Packed-Column, has been conducted using a {minus}100 mesh Illinois No. 5 flotation feed coal sample. The separation performance of each flotation technology was optimized and their performance levels compared on the basis of both ash rejection, sulfur rejection, and throughput capacities. A parametric study using a statistically-designed experimental program was conducted to optimize the critical operating parameter values of each column. The ultimate performance curves for each column were generated by conducting additional tests using the optimized operating parameter values. The throughput capacity of each flotation cell was determined by conducting tests over a range of feed rates at the maximum superficial gas rate while maintaining the other parameters at their optimum values. The separation performance achieved by each of the three flotation cells was found to be comparable to the idealistic flotation performance predicted by release analysis. However, the fraction of wash water reporting to tailings (bias factor) was found to be critical in achieving the near idealistic performance. The bias factor required for the Packed-Column was found to be less than that required by the other two flotation cells. The sulfur rejection achieved by the Microcel and the Packed-Column were found to be greater than that achieved by the Jameson Cell and all three produced sulfur rejections exceeding the values obtained from release analysis. The throughput capacity, on the other hand, differed among the three flotation columns. The Jameson Cell and the Microcel were found to have comparable throughput capacities while the Packed-Column was found to have a lower capacity.

  16. 高柱容量毛细管气相色谱柱研究进展%Progress of High Column Capacity Capillary Column

    Institute of Scientific and Technical Information of China (English)

    周阳; 吴波; 高尧华; 刘磊; 牛娜

    2012-01-01

    随着分析技术和色谱技术的发展,作为气相色谱仪的核心―毛细管柱的制备改进工作取得了丰富的研究成果。本文综述了近年来毛细管气相色谱柱,主要包括大口径、厚液膜毛细管柱、微填充柱、集束毛细管柱、环形毛细管柱及纤维填充柱,在柱容量改进方面的工作及其应用进展。%With the development of analysis and chromatography technology, the preparation of capillary gas chromatography column, as the core of capillary gas chromatography, has obtained abundant research achievements. In this paper, the progress on the development of capillary gas chromatography column capacity and its applications, mainly including those on wide-bore capillary column, micro-packed column, multicapillary column, annular capillary column and fiber packed capillary column, were reviewed.

  17. Sharp spatially constrained inversion

    DEFF Research Database (Denmark)

    Vignoli, Giulio G.; Fiandaca, Gianluca G.; Christiansen, Anders Vest C A.V.C.;

    2013-01-01

    We present sharp reconstruction of multi-layer models using a spatially constrained inversion with minimum gradient support regularization. In particular, its application to airborne electromagnetic data is discussed. Airborne surveys produce extremely large datasets, traditionally inverted...... by using smoothly varying 1D models. Smoothness is a result of the regularization constraints applied to address the inversion ill-posedness. The standard Occam-type regularized multi-layer inversion produces results where boundaries between layers are smeared. The sharp regularization overcomes......, the results are compatible with the data and, at the same time, favor sharp transitions. The focusing strategy can also be used to constrain the 1D solutions laterally, guaranteeing that lateral sharp transitions are retrieved without losing resolution. By means of real and synthetic datasets, sharp...

  18. Multi-Column Experimental Test Bed for Xe/Kr Separation

    Energy Technology Data Exchange (ETDEWEB)

    Greenhalgh, Mitchell Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Garn, Troy Gerry [Idaho National Lab. (INL), Idaho Falls, ID (United States); Welty, Amy Keil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lyon, Kevin Lawrence [Idaho National Lab. (INL), Idaho Falls, ID (United States); Watson, Tony Leroy [Idaho National Lab. (INL), Idaho Falls, ID (United States)ry

    2015-08-31

    Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both

  19. Limits to Nonlinear Inversion

    DEFF Research Database (Denmark)

    Mosegaard, Klaus

    2012-01-01

    For non-linear inverse problems, the mathematical structure of the mapping from model parameters to data is usually unknown or partly unknown. Absence of information about the mathematical structure of this function prevents us from presenting an analytical solution, so our solution depends on our......-heuristics are inefficient for large-scale, non-linear inverse problems, and that the 'no-free-lunch' theorem holds. We discuss typical objections to the relevance of this theorem. A consequence of the no-free-lunch theorem is that algorithms adapted to the mathematical structure of the problem perform more efficiently than...

  20. 'Inverse' temporomandibular joint dislocation.

    Science.gov (United States)

    Alemán Navas, R M; Martínez Mendoza, M G

    2011-08-01

    Temporomandibular joint (TMJ) dislocation can be classified into four groups (anterior, posterior, lateral, and superior) depending on the direction of displacement and the location of the condylar head. All the groups are rare except for anterior dislocation. 'Inverse' TMJ dislocation is a bilateral anterior and superior dislocation with impaction of the mandible over the maxilla; to the authors' knowledge only two cases have previously been reported in the literature. Inverse TMJ dislocation has unique clinical and radiographic findings, which are described for this case. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. VELOCITY AND CONCENTRATION OF BUBBLES IN OZONIZATION COLUMNS WITH CROSS SECTIONS OF DIFFERENT SIZES

    OpenAIRE

    Salla, Marcio Ricardo; Vieira Soares,Leonardo; Alamy Filho,José Eduardo; Daniel,Luiz Antonio; Schulz, Harry Edmar

    2008-01-01

    The size of the cross section of an ozonization column influences its hydrodynamic characteristics, which, on its turn, has effects on phenomena that depend on the relative movement between gas bubbles and liquid. To observe the influence of the cross sectional area on gas concentration and bubbles velocity, two columns were used. The first column had a square cross section with side of 0.19m and the second had a circular cross section with diameter of 0.10 m. The ascendant velocities of the ...

  2. Column flotation monitoring based on electrical capacitance volume tomography: A preliminary study

    Science.gov (United States)

    Haryono, Didied; Harjanto, Sri; Nugraha, Harisma; Huda, Mahfudz Al; Taruno, Warsito Purwo

    2017-01-01

    A preliminary study of column flotation monitoring process using electrical capacitance volume tomography (ECVT) was conducted. ECVT was one of the monitoring systems which based on the capacitance measurement. It was used to understand the phenomenon that occurs inside the column in a three-dimensional (3-D) image. A linear back projection (LBP) algorithm technique was used to reconstruct the 3-D ECVT images from all measurement data obtained in this study. As a preliminary study, the effect of gas injection in the two-phase (liquid and gas) system was conducted. This study is conducted to assess the possibility of ECVT system in the monitoring of column flotation process. The experiments were conducted by using column flotation with 5 cm diameter and 150 cm height in which a sparger was installed at the bottom of column to inject air inside the column. 32-CH rectangular ECVT sensor was installed at 13 cm above the sparger and placed around the column. The gas injection variations used were 2-7 l/min with interval 1 l/min and all experiments were conducted at room temperature. Based on the signal and image analysis, the signals and 3-D ECVT images showed differences when the gas injection was varied. An increase in gas injection will decrease the fluctuation of signal intensity which correlates to the 3-D ECVT images. Average signals obtained by ECVT when given gas injection variations were in the range of 440.09 to 453.62 mV from high to low gas injection. Based on these results, ECVT has a prospect as an imaging tool to monitor the column flotation process. And also, hopefully, based on the analysis of 3-D images generated by ECVT system, the metallurgical performance would be analyzed in the further researches.

  3. The Effect of Aeration on the Growth and Lipid Content on Chlorella vulgaris LICME002 in the Applied Alumina Gas Distributor Bubbling Column Photobioreactor%氧化铝气体分布器应用小球藻培养的研究

    Institute of Scientific and Technical Information of China (English)

    张齐; 高振; 黄和; 梁西海; 纪晓俊; 郑洪立; 尹丰伟

    2011-01-01

    In the study of photobioreactor, gas distributor has great influence to the growth of microalgae,especially in the bubbling column reactor. The effect of the gas-flow rate and CO2 concentration on the biomass,chlorophyll a, and lipid accumulation of Chlorella vulgaris LICME002 in the 5L bubbling photobioreactor with a alumina gas distributor. The results showed that the 3% CO2 is the optimum condition for biomass, chlorophyll a, oil accumulation. When the CO2 concentration exceeded 6% , the algae's parameters decreased significantly.With the analysis of the algae's parameters at 0. lvvm ,0. 4vvm ,0. 7vvm , 1. Ovvm , and the gas-flow rate 0. 4vvm is the best one. Results showed that the optimum gas-flow rate and CO2 concentration, the microalgae biomass can achieve 1. 52 g/L , oil content achieved 31. 5% .%光生物反应器设计中,气体分布器对微藻生长有较大的影响,尤其是在鼓泡式光生物反应器中更为显著.实验考察了采用氧化铝烧制的多孔气体分布器的5L鼓泡式光生物反应器中通气速率、CO2浓度对小球藻HCME002生物量、叶绿素含量、油脂积累的影响.对该气体分布器下的CO2浓度和通气速率对小球藻的作用机理进行了初步的探讨.结果表明,CO2浓度为3%时,该株微藻生物量、叶绿素、油脂积累的最佳;CO2浓度超过6%时各项指标显著下降.通过对0.1vvm,0.4vvm,0.7vvm、1.0vvm的通气速条件下的各项指标的分析,确定最佳通气条件为0.4vvm.结论显示,在最佳通气速率和CO2浓度下,微藻生物量能达到1.52g/L,油脂含量达到31.5%.

  4. Image Appraisal for 2D and 3D Electromagnetic Inversion

    Energy Technology Data Exchange (ETDEWEB)

    Alumbaugh, D.L.; Newman, G.A.

    1999-01-28

    Linearized methods are presented for appraising image resolution and parameter accuracy in images generated with two and three dimensional non-linear electromagnetic inversion schemes. When direct matrix inversion is employed, the model resolution and posterior model covariance matrices can be directly calculated. A method to examine how the horizontal and vertical resolution varies spatially within the electromagnetic property image is developed by examining the columns of the model resolution matrix. Plotting the square root of the diagonal of the model covariance matrix yields an estimate of how errors in the inversion process such as data noise and incorrect a priori assumptions about the imaged model map into parameter error. This type of image is shown to be useful in analyzing spatial variations in the image sensitivity to the data. A method is analyzed for statistically estimating the model covariance matrix when the conjugate gradient method is employed rather than a direct inversion technique (for example in 3D inversion). A method for calculating individual columns of the model resolution matrix using the conjugate gradient method is also developed. Examples of the image analysis techniques are provided on 2D and 3D synthetic cross well EM data sets, as well as a field data set collected at the Lost Hills Oil Field in Central California.

  5. Mapping collapsed columns in coal mines utilizing Microtremor Survey Methods

    Energy Technology Data Exchange (ETDEWEB)

    Xu, P.F.; Li, C.J.; Ling, S.Q.; Zhang, Y.B.; Hou, Z.; Sun, Y.J. [Chinese Academy of Sciences, Beijing (China)

    2009-07-15

    Collapsed columns post one of the deadly safety risks to coal miners. Therefore, how to effectively map collapsed columns has become an urgent business matter for improving coal mine safety and coal production. This article documents the first application of the microtremor survey method to map geological hazards in the coal mining areas. Our results demonstrated the usefulness and effectiveness of the method, primarily due to the sensitivity of shear waves to the low-velocity collapsed columns. In the 2002 working region within the Shanxi Lu'an Zhangcun coal mine area, both the S-wave velocity structure inverted using the simple-point inversion method and the apparent S-wave velocity section obtained using the 2D microtremor profiling method clearly display the known collapsed columns. The collapsed column positions displayed in the 2D microtremor section are consistent with those seen from the tunnel, having a boundary error approximately 10 m. The microtremor method has been proved a very effective and useful geophysical tool to improve coal mining safety, because of the following characteristics: (1) high resolution, (2) no need of using the artificial source, (3) convenient and low-cost field data acquisition, and (4) little effect from local cultural structures. The microtremor survey method is also technically superior to any other geophysical method in detecting or mapping these low or high S-wave velocity anomalies. Therefore, it has a bright future in many geological and geophysical applications, such as investigation of coal seam structures and collapsed columns underneath villages.

  6. 工作场所空气中6种有毒物质的填充柱气相色谱测定法%Simultaneous determination of 6 kinds toxic substances in the air of workplace by packed column gas chromatography

    Institute of Scientific and Technical Information of China (English)

    黄奕涛; 房树超

    2013-01-01

    [Objective] To study and establish a method for simultaneous determination of n- hexane, acetone, methyl ethyl ketone, benzene, toluene, xylene in the air of workplace by packed column gas chromatography. [Methods] Samples were collected by using active carbon tubes, desorbed with carbon bisulfide, separated with constant temperature packed column and detected using FID detector. [Results] Under the established experiment conditions, the 6 kinds of toxic substances were well separated by packed column. The correlative coefficient r was above 0.999. The labeled recovery was from 86.4% to 95.2%. [ Conclusion] This method can effectively separate and accurately determine n- hexane, acetone, methyl ethyl ketone, benzene, toluene, xylene in the air of workplace. Moreover, this method has a simple operation and cheap equipment, and it is especially suitable for laboratory at the grass-roots level.%目的 建立同时测定工作场所空气中正己烷、丙酮、丁酮、苯、甲苯、二甲苯等6种有毒物质的填充物气相色谱法.方法 采用活性炭管吸附采集样品,经二硫化碳解吸后进样,恒温法,填充柱分离,FID检测器气相色谱法检测.结果 在建立的实验条件下,6种待测物质在填充柱上分离良好,工作曲线的相关系数r值在0.999以上,加标回收率在86.4% ~95.2%之间.结论 该方法能有效分离和准确测定工作场所空气中正己烷、丙酮、丁酮、苯、甲苯、二甲苯等6种有毒物质,且操作简单,所需仪器设备便宜,尤其适用于基层实验室.

  7. A hybrid genetic algorithm to optimize simple distillation column sequences

    Institute of Scientific and Technical Information of China (English)

    GAN YongSheng; Andreas Linninger

    2004-01-01

    Based on the principles of Genetic Algorithms (GAs), a hybrid genetic algorithm used to optimize simple distillation column sequences was established. A new data structure, a novel arithmetic crossover operator and a dynamic mutation operator were proposed. Together with the feasibility test of distillation columns, they are capable to obtain the optimum simple column sequence at one time without the limitation of the number of mixture components, ideal or non-ideal mixtures and sloppy or sharp splits. Compared with conventional algorithms, this hybrid genetic algorithm avoids solving complicated nonlinear equations and demands less derivative information and computation time. Result comparison between this genetic algorithm and Underwood method and Doherty method shows that this hybrid genetic algorithm is reliable.

  8. Study on the Axial Dispersion of Liquid in Column Flotation

    Institute of Scientific and Technical Information of China (English)

    周鵾; 曾爱武; 高长宝; 余国琮

    2003-01-01

    An experimental study on the axial dispersion of liquid was carried out in a 0.382-m-ID flotation column packed with different structured packings or free of packings. The correlations of axial Peclet numbers with the liquid and gas superficial Reynolds numbers were developed for various packings. Among the packings tested, it is found that in the column packed with 250Y or 350Y packings the axial dispersion is the lowest. The addition of frother can decrease the axial dispersion. By the simulation analysis of the one-dimension dispersion model of packed flotation column, it is found that small axial dispersion, high collection rate constant and low axial liquid velocity can increase the collection zone recovery.

  9. Inversion domains in AlN grown on (0001) sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Jasinski, J.; Liliental-Weber, Z.; Paduano, Q.S.; Weyburne, D.W.

    2003-08-25

    Al-polarity inversion domains formed during AlN layer growth on (0001) sapphire were identified using transmission electron microscopy (TEM). They resemble columnar inversion domains reported for GaN films grown on (0001) sapphire. However, for AlN, these columns have a V-like shape with boundaries that deviate by 2 {+-} 0.5{sup o} from the c-axis. TEM identification of these defects agrees with the post-growth surface morphology as well as with the microstructure revealed by etching in hot aqueous KOH.

  10. Locative Inversion in English

    NARCIS (Netherlands)

    Broekhuis, H.

    2005-01-01

    This article aims at reformulating in more current terms Hoekstra and Mulder’s (1990) analysis of the Locative Inversion (LI) construction. The new proposal is crucially based on the assumption that Small Clause (SC) predicates agree with their external argument in phi-features, which may be morphol

  11. Nitrogen removal from urban stormwater runoff through layered bioretention columns.

    Science.gov (United States)

    Hsieh, Chi-hsu; Davis, Allen P; Needelman, Brian A

    2007-11-01

    Bioretention is a low-impact technology used for the treatment of stormwater runoff in developed areas. The fates of mineral nitrogen compounds in two bioretention columns (RP1 and RP2) with different media-layering characteristics were investigated under multiple loadings of simulated urban runoff. The immediate capture of nitrogen was evaluated, with nitrogen transformation reactions that occurred during the drying periods between rainfall events. A greater proportion of ammonium was removed from runoff in RP2 (68 +/- 16%), which had a high permeability layer over a lower permeability layer, than in RP1 (12 +/- 6%), which had the inverse configuration. Both column systems demonstrated nitrate export (9 +/- 32% and 54 +/- 22% greater than input for RP1 and RP2, respectively), attributed to washout of nitrate resulting from nitrification processes between runoff loading events. Bioretention media with a less permeable bottom soil layer could form an anoxic/anaerobic zone for promoting nitrification/denitrification processes.

  12. Bayesian seismic AVO inversion

    Energy Technology Data Exchange (ETDEWEB)

    Buland, Arild

    2002-07-01

    A new linearized AVO inversion technique is developed in a Bayesian framework. The objective is to obtain posterior distributions for P-wave velocity, S-wave velocity and density. Distributions for other elastic parameters can also be assessed, for example acoustic impedance, shear impedance and P-wave to S-wave velocity ratio. The inversion algorithm is based on the convolutional model and a linearized weak contrast approximation of the Zoeppritz equation. The solution is represented by a Gaussian posterior distribution with explicit expressions for the posterior expectation and covariance, hence exact prediction intervals for the inverted parameters can be computed under the specified model. The explicit analytical form of the posterior distribution provides a computationally fast inversion method. Tests on synthetic data show that all inverted parameters were almost perfectly retrieved when the noise approached zero. With realistic noise levels, acoustic impedance was the best determined parameter, while the inversion provided practically no information about the density. The inversion algorithm has also been tested on a real 3-D dataset from the Sleipner Field. The results show good agreement with well logs but the uncertainty is high. The stochastic model includes uncertainties of both the elastic parameters, the wavelet and the seismic and well log data. The posterior distribution is explored by Markov chain Monte Carlo simulation using the Gibbs sampler algorithm. The inversion algorithm has been tested on a seismic line from the Heidrun Field with two wells located on the line. The uncertainty of the estimated wavelet is low. In the Heidrun examples the effect of including uncertainty of the wavelet and the noise level was marginal with respect to the AVO inversion results. We have developed a 3-D linearized AVO inversion method with spatially coupled model parameters where the objective is to obtain posterior distributions for P-wave velocity, S

  13. A "Greenhouse Gas" Experiment for the Undergraduate Laboratory

    Science.gov (United States)

    Gomez, Elaine; Paul, Melissa; Como, Charles; Barat, Robert

    2014-01-01

    This experiment and analysis offer an effective experience in greenhouse gas reduction. Ammoniated water is flowed counter-current to a simulated flue gas of air and CO2 in a packed column. The gaseous CO2 concentrations are measured with an on-line, non- dispersive, infrared analyzer. Column operating parameters include total gas flux, dissolved…

  14. Calculation of the inverse data space via sparse inversion

    KAUST Repository

    Saragiotis, Christos

    2011-01-01

    The inverse data space provides a natural separation of primaries and surface-related multiples, as the surface multiples map onto the area around the origin while the primaries map elsewhere. However, the calculation of the inverse data is far from trivial as theory requires infinite time and offset recording. Furthermore regularization issues arise during inversion. We perform the inversion by minimizing the least-squares norm of the misfit function by constraining the $ell_1$ norm of the solution, being the inverse data space. In this way a sparse inversion approach is obtained. We show results on field data with an application to surface multiple removal.

  15. Pseudo waveform inversion

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Chang Soo; Park, Keun Pil [Korea Inst. of Geology Mining and Materials, Taejon (Korea, Republic of); Suh, Jung Hee; Hyun, Byung Koo; Shin, Sung Ryul [Seoul National University, Seoul (Korea, Republic of)

    1995-12-01

    The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. However, the imagining of subsurface based on the conventional data processing is almost impossible to obtain the information on physical properties of the subsurface such as velocity and density. Since seismic data are implicitly function of velocities of subsurface, it is necessary to develop the inversion method that can delineate the velocity structure using seismic topography and waveform inversion. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that calculate the travel time of the complex geologic structure using shooting ray tracing by subdividing the geologic model into blocky structure having the constant velocity. With the travel time calculation, the partial derivatives of travel time can be calculated efficiently without difficulties. Since the current ray tracing technique has a limitation to calculate the travel times for extremely complex geologic model, our aim in the future is to develop the powerful ray tracer using the finite element technique. After applying the pseudo waveform inversion to the seismic data of Korea offshore, we can obtain the subsurface velocity model and use the result in bring up the quality of the seismic data processing. If conventional seismic data processing and seismic interpretation are linked with this inversion technique, the high quality of seismic data processing can be expected to image the structure of the subsurface. Future research area is to develop the powerful ray tracer of ray tracing which can calculate the travel times for the extremely complex geologic model. (author). 39 refs., 32 figs., 2 tabs.

  16. Column Holdup Formula of Soil Solute Transport

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The shortcomings of the present two formulae for describing column holdup are analyzed and deductions are made to find a new formula. The column holdup, Hw, described by the new formula is dimensional,and related to soil solute transport kinesis and column physical properties. Compared with the other two column holdups, Hw is feasible to describe dimensional column holdup during solute transport process. The relationships between Hw and retardation factor, R, in different solute transport boundary conditions are established.

  17. Methodological analysis of gamma tomography system for large random packed columns

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, Pablo A.S.; De Mesquita, Carlos H. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900, Sao Paulo (Brazil); LeRoux, Galo A.C. [Departamento de Engenharia Quimica, Escola Politecnica da Universidade de Sao Paulo, Prof. Luciano Gualberto, Trav. 3, 380-Cidade Universitaria, 05508-900, Sao Paulo (Brazil); Hamada, Margarida M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900, Sao Paulo (Brazil)], E-mail: mmhamada@ipen.br

    2010-04-15

    Gamma ray tomography experiments have been carried out to detect spatial patterns in the porosity in a 0.27 m diameter column packed with steel Rashig rings of different sizes: 12.6, 37.9, and 76 mm. using a first generation CT system. A fast Fourier transform tomographic reconstruction algorithm has been used to calculate the spatial variation over the column cross section. Cross-sectional gas porosity and solid holdup distribution were determinate. The values of cross-sectional average gas porosity were {epsilon}=0.849, 0.938 and 0.966 for the 12.6, 37.9, and 76 mm rings, respectively. Radial holdup variation within the packed bed has been determined. The variation of the circumferentially averaged gas holdup in the radial direction indicates that the porosity in the column wall region is a somewhat higher than that in the bulk region, due to the effect of the column wall.

  18. Partially saturated granular column collapse

    Science.gov (United States)

    Turnbull, Barbara; Johnson, Chris

    2017-04-01

    Debris flows are gravity-driven sub-aerial mass movements containing water, sediments, soil and rocks. These elements lead to characteristics common to dry granular media (e.g. levee formation) and viscous gravity currents (viscous fingering and surge instabilities). The importance of pore fluid in these flows is widely recognised, but there is significant debate over the mechanisms of build up and dissipation of pore fluid pressure within debris flows, and the resultant effect this has on dilation and mobility of the grains. Here we specifically consider the effects of the liquid surface in the flow. We start with a simple experiment constituting a classical axisymmetric granular column collapse, but with fluid filling the column up to a depth comparable to the depth of grains. Thus, as the column collapses, capillary forces may be generated between the grains that prevent dilation. We explore a parameter space to uncover the effects of fluid viscosity, particle size, column size, aspect ratio, grain shape, saturation level, initial packing fraction and significantly, the effects of fine sediments in suspension which can alter the capillary interaction between wetted macroscopic grains. This work presents an initial scaling analysis and attempts to relate the findings to current debris flow modelling approaches.

  19. Neural network based control of an absorption column in the process of bioethanol production

    Directory of Open Access Journals (Sweden)

    Eduardo Eyng

    2009-08-01

    Full Text Available Gaseous ethanol may be recovered from the effluent gas mixture of the sugar cane fermentation process using a staged absorption column. In the present work, the development of a nonlinear controller, based on a neural network inverse model (ANN controller, was proposed and tested to manipulate the absorbent flow rate in order to control the residual ethanol concentration in the effluent gas phase. Simulation studies were carried out, in which a noise was applied to the ethanol concentration signals from the rigorous model. The ANN controller outperformed the dynamic matrix control (DMC when step disturbances were imposed to the gas mixture composition. A security device, based on a conventional feedback algorithm, and a digital filter were added to the proposed strategy to improve the system robustness when unforeseen operating and environmental conditions occured. The results demonstrated that ANN controller was a robust and reliable tool to control the absorption column.Deseja-se recuperar o etanol perdido por evaporação durante o processo de fermentação da cana-de-açúcar. Para tanto, faz-se uso de uma coluna de absorção. O controle da concentração de etanol no efluente gasoso da coluna é realizado pela manipulação da vazão de solvente, sendo esta determinada pelo controlador não linear proposto, baseado em um modelo inverso de redes neurais (controlador ANN. Foram feitas simulações adicionando-se um sinal de ruído a medida de concentração de etanol na fase gasosa. Quando perturbações degrau foram inseridas na mistura gasosa afluente, o controlador ANN demonstrou desempenho superior ao controle por matriz dinâmica (DMC. Um dispositivo de segurança, baseado em um controlador feedback convencional, e um filtro digital foram implementados à estratégia de controle proposta para agregar robustez no tratamento de distúrbios ocorridos no ambiente operacional. Os resultados demonstraram que o controlador ANN é uma

  20. The Moore-Penrose Inverse of Block Magic Rectangles

    Science.gov (United States)

    Hakopian, Y. R.; Eloyan, A. N.

    2007-01-01

    As is known, a semi-magic square is an "n x n" matrix having the sum of entries in each row and each column equal to a constant. This note generalizes this notion and introduce a special class of block matrices called "block magic rectangles." It is proved that the Moore-Penrose inverse of a block magic rectangle is also a block magic rectangle.

  1. Stratigraphic inversion of pre-stack multicomponent data; Inversion stratigraphique multicomposante avant sommation

    Energy Technology Data Exchange (ETDEWEB)

    Agullo, Y.

    2005-09-15

    This thesis present the extension of mono-component seismic pre-stack data stratigraphical inversion method to multicomponent data, with the objective of improving the determination of reservoir elastic parameters. In addiction to the PP pressure waves, the PS converted waves proved their interest for imaging under gas clouds; and their potential is highly significant for the characterization of lithologies, fluids, fractures... Nevertheless the simultaneous use ol PP and PS data remains problematic because of their different the time scales. To jointly use the information contained in PP and PS data, we propose a method in three steps first, mono-component stratigraphic inversions of PP then PS data; second, estimation of the PP to PS time conversion law; third, multicomponent stratigraphic inversion. For the second point, the estimation of the PP to PS conversion law is based on minimizing the difference between the S impedances obtained from PP and PS mono-component stratigraphic inversion. The pre-stack mono-component stratigraphic inversions was adapted to the case of multicomponent data by leaving each type of data in its own time scale in order to avoid the distortion of the seismic wavelet. The results obtained on a realistic synthetic PP-PS case show on one hand that determining PP to PS conversion law (from the mono-component inversion results) is feasible, and on the other hand that the joint inversion of PP and PS data with this conversion law improves the results compared to the mono-component inversion ones. Although this is presented within the framework of the PP and PS multi-component data, the developed methodology adapts directly to PP and SS data for example. (author)

  2. Anaerobic digestion of dairy wastewater by inverse fluidization: the inverse fluidized bed and the inverse turbulent bed reactors.

    Science.gov (United States)

    Arnaiz, C; Buffiere, P; Elmaleh, S; Lebrato, J; Moletta, R

    2003-11-01

    This paper describes the application of the inverse fluidization technology to the anaerobic digestion of dairy wastewater. Two reactors were investigated: the inverse fluidized bed reactor and the inverse turbulent reactor. In these reactors, a granular floating solid is expanded by a down-flow current of effluent or an up-flow current of gas, respectively. The carrier particles (Extendospheres) were chosen for their large specific surface area (20,000 m2m(-3)) and their low energy requirements for fluidization (gas velocity of 1.5 mm s(-1), 5.4 m h(-1)). Organic load was increased stepwise by reducing hydraulic retention time from more than 60 days to 3 days, while maintaining constant the feed COD concentration. Both reactors achieved more than 90% of COD removal, at an organic loading rate of 10-12 kgCOD m(-3) d(-1), respectively. The performances observed were similar or even higher than that of other previously tested fluidized bed technologies treating the same wastewater. It was found that the main advantages of this system are: low energy requirement, because of the low fluidization velocities required; there is no need of a settling device, because solids accumulate at the bottom of the reactor, so they can be easily drawn out and particles with high-biomass content can be easily recovered. Lipid phosphate concentration has been revealed as a good method for biomass estimation in biofilms since it only includes living biomass.

  3. Influence of Water Addition on Crystalline Silicotitanate Column Operation

    Energy Technology Data Exchange (ETDEWEB)

    Stallings, M.E.

    2001-09-11

    The proposed use of crystalline silicotitanate (CST) for removal of radiocesium from Savannah River high level waste has received significant research over the past few years. Engineering evaluations of the proposed flow sheet identified several risks. These risks include chemical and thermal stability of the resin, gas generation in the large ion exchange columns, and size reduction and sampling issues for interfacing with the Defense Waste Processing Facility. Research into these potential risks provided information that mitigates or eliminates these risks.

  4. Noble gas fractionation during subsurface gas migration

    Science.gov (United States)

    Sathaye, Kiran J.; Larson, Toti E.; Hesse, Marc A.

    2016-09-01

    Environmental monitoring of shale gas production and geological carbon dioxide (CO2) storage requires identification of subsurface gas sources. Noble gases provide a powerful tool to distinguish different sources if the modifications of the gas composition during transport can be accounted for. Despite the recognition of compositional changes due to gas migration in the subsurface, the interpretation of geochemical data relies largely on zero-dimensional mixing and fractionation models. Here we present two-phase flow column experiments that demonstrate these changes. Water containing a dissolved noble gas is displaced by gas comprised of CO2 and argon. We observe a characteristic pattern of initial co-enrichment of noble gases from both phases in banks at the gas front, followed by a depletion of the dissolved noble gas. The enrichment of the co-injected noble gas is due to the dissolution of the more soluble major gas component, while the enrichment of the dissolved noble gas is due to stripping from the groundwater. These processes amount to chromatographic separations that occur during two-phase flow and can be predicted by the theory of gas injection. This theory provides a mechanistic basis for noble gas fractionation during gas migration and improves our ability to identify subsurface gas sources after post-genetic modification. Finally, we show that compositional changes due to two-phase flow can qualitatively explain the spatial compositional trends observed within the Bravo Dome natural CO2 reservoir and some regional compositional trends observed in drinking water wells overlying the Marcellus and Barnett shale regions. In both cases, only the migration of a gas with constant source composition is required, rather than multi-stage mixing and fractionation models previously proposed.

  5. Columns

    Institute of Scientific and Technical Information of China (English)

    于晓悠; 丁燕燕; 韩多妮; Ray; Carrie; 未冉

    2010-01-01

    <正>New York Whitney艺术双年展今年第75届纽约Whitney双年展不设题目,但以"2010"指示策展方向,继续以发掘年轻艺术家、展示创作实验为目标。参展的55位艺术家,最年轻的是23岁摄影师Tam Tran,最老资历的是75岁的概念艺术家Lorraine O’Grady。这届的另一先创性,是每位艺术家只限一件或一个系列的作品,避免了去届双年展的"小型个人回顾展"现象,而五层楼的展场各有特色,如录像及短片将独立于三楼展出,而美术馆馆藏则移师五楼。这届双年展由著名的意大利策展人Francesco Bonami联同助手Gary Carrion-Murayarn共同制作,两位策展人说明,双年展的重要性是预示未来,创新及前瞻性依然是取决原则。

  6. Columns

    Institute of Scientific and Technical Information of China (English)

    Carrie Tsang; 丁燕燕; 韩多妮; RAY

    2009-01-01

    <正>Paris承诺的展现33岁的墨西哥艺术家Mario Garcia Torres是近年国际艺坛炙手可热的新星,他以录象、摄影、幻灯及装置为创作形式,透过个人视点及独特演绎手法来重新思考历史。他是一个思考型艺术家,同时又是一个淘气的大孩子,作品往往反映了他的双重性格——嬉戏中带有深沉的历史感。这次是GarciaTorres首次在法国的国家博物馆举行展览,整合出版了他过往两年间在

  7. Technical Note: Methods for interval constrained atmospheric inversion of methane

    Directory of Open Access Journals (Sweden)

    J. Tang

    2010-08-01

    Full Text Available Three interval constrained methods, including the interval constrained Kalman smoother, the interval constrained maximum likelihood ensemble smoother and the interval constrained ensemble Kalman smoother are developed to conduct inversions of atmospheric trace gas methane (CH4. The negative values of fluxes in an unconstrained inversion are avoided in the constrained inversion. In a multi-year inversion experiment using pseudo observations derived from a forward transport simulation with known fluxes, the interval constrained fixed-lag Kalman smoother presents the best results, followed by the interval constrained fixed-lag ensemble Kalman smoother and the interval constrained maximum likelihood ensemble Kalman smoother. Consistent uncertainties are obtained for the posterior fluxes with these three methods. This study provides alternatives of the variable transform method to deal with interval constraints in atmospheric inversions.

  8. Reduced Bayesian Inversion

    OpenAIRE

    Himpe, Christian; Ohlberger, Mario

    2014-01-01

    Bayesian inversion of models with large state and parameter spaces proves to be computationally complex. A combined state and parameter reduction can significantly decrease the computational time and cost required for the parameter estimation. The presented technique is based on the well-known balanced truncation approach. Classically, the balancing of the controllability and observability gramians allows a truncation of discardable states. Here the underlying model, being a linear or nonline...

  9. The Fukushima Inverse Problem

    OpenAIRE

    Martinez-Camara, Marta; Dokmanic, Ivan; Ranieri, Juri; Scheibler, Robin; Vetterli, Martin; STOHL Andreas

    2013-01-01

    Knowing what amount of radioactive material was released from Fukushima in March 2011 and at what time instants is crucial to assess the risk, the pollution, and to understand the scope of the consequences. Moreover, it could be used in forward simulations to obtain accurate maps of deposition. But these data are often not publicly available. We propose to estimate the emission waveforms by solving an inverse problem. Previous approaches have relied on a detailed expert guess of how the relea...

  10. Mass transfer in wetted-wall columns: correlations at high Reynolds numbers

    DEFF Research Database (Denmark)

    Nielsen, Christian H.E.; Kiil, Søren; Thomsen, Henrik W.;

    1998-01-01

    The rate of gas-and liquid-phase mass transport in a pilot-scale wetted-wall column with an inner diameter of 3.26 cm and a length of 5 m was investigated. Empirical correlations for the physical liquid-phase mass transfer coefficient (k(L)(O)) and the gas-phase mass transfer coefficient (k...

  11. Method of analysis and quality-assurance practices for determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry at the U.S. Geological Survey California District Organic Chemistry Laboratory, 1996-99

    Science.gov (United States)

    Crepeau, Kathryn L.; Baker, Lucian M.; Kuivila, Kathryn M.

    2000-01-01

    A method of analysis and quality-assurance practices were developed to study the fate and transport of pesticides in the San Francisco Bay-Estuary by the U.S. Geological Survey. Water samples were filtered to remove suspended-particulate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide and the pesticides were eluted with three cartridge volumes of hexane:diethyl ether (1:1) solution. The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for pesticides ranged from 0.002 to 0.025 microgram per liter for 1-liter samples. Recoveries ranged from 44 to 140 percent for 25 pesticides in samples of organic-free reagent water and Sacramento-San Joaquin Delta and Suisun Bay water fortified at 0.05 and 0.50 microgram per liter. The estimated holding time for pesticides after extraction on C-8 solid-phase extraction cartridges ranged from 10 to 257 days.

  12. [Total inversion of the uterus].

    Science.gov (United States)

    Novachkov, V; Baltadzhieva, B; Ilieva, A; Rachev, E

    2008-01-01

    Non puerperal inversion of the uterus is very uncommon. Patients may present with pelvic pain, vaginal bleeding or hemodynamic shock. We report a fifty five old woman with uterus inversion second stage.

  13. Mathematical analysis of intermittent gas injection model in oil production

    Science.gov (United States)

    Tasmi, Silvya, D. R.; Pudjo, S.; Leksono, M.; Edy, S.

    2016-02-01

    Intermittent gas injection is a method to help oil production process. Gas is injected through choke in surface and then gas into tubing. Gas forms three areas in tubing: gas column area, film area and slug area. Gas column is used to propel slug area until surface. A mathematical model of intermittent gas injection is developed in gas column area, film area and slug area. Model is expanding based on mass and momentum conservation. Using assume film thickness constant in tubing, model has been developed by Tasmi et. al. [14]. Model consists of 10 ordinary differential equations. In this paper, assumption of pressure in gas column is uniform. Model consist of 9 ordinary differential equations. Connection of several variables can be obtained from this model. Therefore, dynamics of all variables that affect to intermittent gas lift process can be seen from four equations. To study the behavior of variables can be analyzed numerically and mathematically. In this paper, simple mathematically analysis approach is used to study behavior of the variables. Variables that affect to intermittent gas injection are pressure in upstream valve and in gas column. Pressure in upstream valve will decrease when gas mass in valve greater than gas mass in choke. Dynamic of the pressure in the gas column will decrease and increase depending on pressure in upstream valve.

  14. Comparison of drug substance impurity profiles generated with extended length columns during packed-column SFC.

    Science.gov (United States)

    Roston, D A; Ahmed, S; Williams, D; Catalano, T

    2001-10-01

    The current study assesses the effect of extending column length during gradient packed column sub/supercritical fluid chromatography (PCSFC) experiments on the detection of known and unknown impurities in a drug substance sample. Quantitative drug substance impurity profiles were generated and compared using multiple column PCSFC and HPLC conditions. Also, chromatographic figures of merit were estimated and compared for components of a standard mixture during PCSFC experiments, which used one column, four columns, and six columns in series.

  15. Water Column Methylation in Estuaries

    Science.gov (United States)

    Schartup, A. T.; Calder, R.; Soerensen, A. L.; Mason, R. P.; Balcom, P. H.; Sunderland, E. M.

    2014-12-01

    Methylmercury (MeHg) is a neurotoxin that bioaccumulates in aquatic food webs and affects humans and wildlife through fish consumption. Many studies have measured active methylation/demethylation in ocean margin sediments but few have reported similar rates for the marine water column. This presentation will review available evidence for water column methylation in estuaries, including new experimental measurements of methylation/demethylation rates from a deep subarctic fjord in Labrador Canada collected in Spring and Fall of 2012-2013. We used these and other data to construct a mass budget for MeHg in the estuary and show that water column methylation (with rates ranging from 1.5 to 2.8 % day-1), is the largest contributor, followed by inputs from rivers (4.9 mol year-1), to the in situ pool of MeHg available for uptake by biota. By contrast, the sediment in this system is a net sink for MeHg (-1.5 mol year-1). We discuss the relationship between observed MeHg and other ancillary environmental factors (organic carbon, sulfur and nutrients) as well as implications for the response time of fish to future changes in mercury inputs.

  16. ENGINEERING DEVELOPMENT OF SLURRY BUBBLE COLUMN REACTOR (SBCR) TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Bernard A. Toseland

    2000-12-31

    The major technical objectives of this program are threefold: (1) to develop the design tools and a fundamental understanding of the fluid dynamics of a slurry bubble column reactor to maximize reactor productivity, (2) to develop the mathematical reactor design models and gain an understanding of the hydrodynamic fundamentals under industrially relevant process conditions, and (3) to develop an understanding of the hydrodynamics and their interaction with the chemistries occurring in the bubble column reactor. Successful completion of these objectives will permit more efficient usage of the reactor column and tighter design criteria, increase overall reactor efficiency, and ensure a design that leads to stable reactor behavior when scaling up to large-diameter reactors. Washington University's work during the reporting period involved the implementation of the automated calibration device, which will provide an advanced method of determining liquid and slurry velocities at high pressures. This new calibration device is intended to replace the original calibration setup, which depended on fishing lines and hooks to position the radioactive particle. The report submitted by Washington University contains a complete description of the new calibration device and its operation. Improvements to the calibration program are also discussed. Iowa State University utilized air-water bubble column simulations in an effort to determine the domain size needed to represent all of the flow scales in a gas-liquid column at a high superficial velocity. Ohio State's report summarizes conclusions drawn from the completion of gas injection phenomena studies, specifically with respect to the characteristics of bubbling-jetting at submerged single orifices in liquid-solid suspensions.

  17. Unveiling Sources of Heating in the Vicinity of the Orion BN/KL Hot Core as Traced by Highly Excited Inversion Transitions of Ammonia

    CERN Document Server

    Goddi, C; Humphreys, E M L; Chandler, C J; Matthews, L D

    2011-01-01

    Using the Expanded Very Large Array, we have mapped the vicinity of the Orion BN/KL Hot Core with sub-arcsecond angular resolution in seven metastable inversion transitions of ammonia: (J,K)=(6,6) to (12,12). This emission comes from levels up to 1500 K above the ground state, enabling identification of source(s) responsible for heating the region. We used this multi-transition dataset to produce images of the rotational/kinetic temperature and the column density of ammonia for ortho and para species separately and on a position-by-position basis. We find rotational temperature and column density in the range 160-490 K and (1-4)x10^17 cm^-2, respectively. Our spatially-resolved images show that the highest (column) density and hottest gas is found in a northeast-southwest elongated ridge to the southeast of Source I. We have also measured the ortho-para ratio of ammonia, estimated to vary in the range 0.9-1.6. Enhancement of ortho with respect to para and the offset of hot ammonia emission peaks from known (p...

  18. Some hydrodynamic aspects of 3-phase inverse fluidized bed

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Hydrodynamics of 3-phase inverse fluidized bed is studied experimentally using low density particles for different liquid and gas velocities.The hydrodynamic characteristics studied include pressure drop, minimum liquid and gas fluidization velocities and phase holdups. The minimum liquid fluidization velocity determined using the bed pressure gradient, decreases with increase in gas velocity. The axial profiles of phase holdups shows that the liquid holdup increases along the bed height, whereas the solid holdup decreases down the bed. However, the gas holdup is almost uniform in the bed.

  19. A novel gridding algorithm to create regional trace gas maps from satellite observations

    Directory of Open Access Journals (Sweden)

    G. Kuhlmann

    2014-02-01

    Full Text Available The recent increase in spatial resolution for satellite instruments has made it feasible to study distributions of trace gas column densities on a regional scale. For this application a new gridding algorithm was developed to map measurements from the instrument's frame of reference (level 2 onto a longitude–latitude grid (level 3. The algorithm is designed for the Ozone Monitoring Instrument (OMI and can easily be employed for similar instruments – for example, the upcoming TROPOspheric Monitoring Instrument (TROPOMI. Trace gas distributions are reconstructed by a continuous parabolic spline surface. The algorithm explicitly considers the spatially varying sensitivity of the sensor resulting from the instrument function. At the swath edge, the inverse problem of computing the spline coefficients is very sensitive to measurement errors and is regularised by a second-order difference matrix. Since this regularisation corresponds to the penalty term for smoothing splines, it similarly attenuates the effect of measurement noise over the entire swath width. Monte Carlo simulations are conducted to study the performance of the algorithm for different distributions of trace gas column densities. The optimal weight of the penalty term is found to be proportional to the measurement uncertainty and the width of the instrument function. A comparison with an established gridding algorithm shows improved performance for small to moderate measurement errors due to better parametrisation of the distribution. The resulting maps are smoother and extreme values are more accurately reconstructed. The performance improvement is further illustrated with high-resolution distributions obtained from a regional chemistry model. The new algorithm is applied to tropospheric NO2 column densities measured by OMI. Examples of regional NO2 maps are shown for densely populated areas in China, Europe and the United States of America. This work demonstrates that the newly

  20. A novel gridding algorithm to create regional trace gas maps from satellite observations

    Directory of Open Access Journals (Sweden)

    G. Kuhlmann

    2013-08-01

    Full Text Available Recent increase of spatial resolution for satellite instruments has it made feasible to study distributions of trace gas column densities on a regional scale. For this application a new gridding algorithm was developed to map measurements from the instrument's frame of reference (Level 2 onto a longitude-latitude grid (Level 3. The algorithm is designed for the Ozone Monitoring Instrument (OMI and can be employed easily to similar instruments, for example, the upcoming TROPOspheric Monitoring Instrument (TROPOMI. Trace gas distributions are reconstructed by a continuous parabolic spline surface. The algorithm explicitly considers the spatially varying sensitivity of the sensor resulting from the instrument function. At the swath edge, the inverse problem of computing the spline coefficients is very sensitive to measurement errors and is regularised by a second-order difference matrix. Since this regularisation corresponds to the penalty term for smoothing splines, it similarly attenuates the effect of measurement noise over the entire swath width. Monte Carlo simulations are conducted to study the performance of the algorithm for different distributions of trace gas column densities. The optimal weight of the penalty term is found to be proportional to the measurement uncertainty and the width of the instrument function. A comparison with an established gridding algorithm shows improved performance for small to moderate measurement errors due to better parametrization of the distribution. The resulting maps are smoother and extreme values are more accurately reconstructed. The performance improvement is further illustrated with high-resolution distributions obtained from a regional chemistry model. The new algorithm is applied to tropospheric NO2 column densities measured by OMI. Examples of regional NO2 maps are shown for densely populated areas in China, Europe and the United States of America. This work demonstrates that the newly developed

  1. A radiation-hydrodynamics model of accretion columns for ultra-luminous X-ray pulsars

    Science.gov (United States)

    Kawashima, Tomohisa; Mineshige, Shin; Ohsuga, Ken; Ogawa, Takumi

    2016-10-01

    Prompted by the recent discovery of pulsed emission from an ultra-luminous X-ray source, M 82 X-2 ("ULX-pulsar"), we perform a two-dimensional radiation-hydrodynamics simulation of a supercritical accretion flow onto a neutron star through a narrow accretion column. We set an accretion column with a cone shape filled with tenuous gas with the density of 10-4 g cm-3 above a neutron star and solve the two-dimensional gas motion and radiative transfer within the column. The side boundaries are set such that radiation can freely escape, but gas cannot. Since the initial gas layer is not in a hydrostatic balance, the column gas falls onto the neutron-star surface, and thereby a shock is generated. As a result, the accretion column is composed of two regions: an upper, nearly free-fall region and a lower settling region, as noted by Basko and Sunyaev (1976, MNRAS, 175, 395). The average accretion rate is very high; dot{M}˜ 10^{2{-}3} L_E/c2 (with LE being the Eddington luminosity), and so radiation energy dominates over gas internal energy entirely within the column. Despite the high accretion rate, the radiation flux in the laboratory frame is kept barely below LE/(4πr2) at a distance r in the settling region so that matter can slowly accrete. This adjustment is made possible, since a large amount of photons produced via dissipation of kinetic energy of matter can escape through the side boundaries. The total luminosity can greatly exceed LE by several orders of magnitude, whereas the apparent luminosity observed from the top of the column is much less. Due to such highly anisotropic radiation fields, the observed flux should exhibit periodic variations with the rotation period, provided that the rotation and magnetic axes are misaligned.

  2. Inversion assuming weak scattering

    DEFF Research Database (Denmark)

    Xenaki, Angeliki; Gerstoft, Peter; Mosegaard, Klaus

    2013-01-01

    The study of weak scattering from inhomogeneous media or interface roughness has long been of interest in sonar applications. In an acoustic backscattering model of a stationary field of volume inhomogeneities, a stochastic description of the field is more useful than a deterministic description...... due to the complex nature of the field. A method based on linear inversion is employed to infer information about the statistical properties of the scattering field from the obtained cross-spectral matrix. A synthetic example based on an active high-frequency sonar demonstrates that the proposed...

  3. Inverse Degree and Connectivity

    Institute of Scientific and Technical Information of China (English)

    MA Xiao-ling; TIAN Ying-zhi

    2013-01-01

    Let G be a connected graph with vertex set V(G),order n =丨V(G)丨,minimum degree δ(G) and connectivity κ(G).The graph G is called maximally connected if κ(G) =δ(G).Define the inverse degree of G with no isolated vertices as R(G) =Σv∈V(G)1/d(v),where d(v) denotes the degree of the vertex v.We show that G is maximally connected if R(G) < 1 + 2/δ + n-2δ+1/(n-1)(n-3).

  4. Eruption column height: a comparison between ground and satellite measurements

    Science.gov (United States)

    Scollo, Simona; Prestifilippo, Michele; Pecora, Emilio; Corradini, Stefano; Merucci, Luca; Spata, Gaetano; Coltelli, Mauro

    2014-05-01

    The eruption column height estimation is an essential parameter to evaluate the total mass eruption rate, the gas and aerosol plume dispersal and retrievals. The column height may be estimated using different systems (e.g. satellite, aircraft and ground observations) which may present marked differences. In this work we use the calibrated images collected by the video-surveillance system of the Istituto Nazionale di Geofisica e Vulcanologia, Osservatorio Etneo, from the visible camera located in Catania, 27 km from the vent. The analysis is carried out on twenty lava fountains from the New South East Crater during the recent Etna explosive activity. Firstly, we calibrated the camera to estimate its intrinsic parameters and the full camera model. Furthermore, we selected the images which recorded the maximum phase of the eruptive activity. Hence, we applied an appropriate correction to take into account the wind effect. The column height was also evaluated using SEVIRI and MODIS satellite images collected at the same time of the video camera measurements. The satellite column height retrievals is realized by comparing the 11 μm brightness temperature of the most opaque plume pixels with the atmospheric temperature profile measured at Trapani WMO Meteo station (the nearest WMO station to the Etnean area). The comparison between satellite and ground data show a good agreement and the column altitudes ranges between 7.5 and 9 km (upper limit of the camera system). For nine events we evaluated also the thickness of the volcanic plumes in the umbrella region (near the vent) which ranges between 2 and 3 km. The proposed approach help to quantitatively evaluate the column height that may be used by volcanic ash dispersal and sedimentation models for improving forecasts and reducing risks to aviation during volcanic crisis.

  5. A radiation-hydrodynamic model of accretion columns for ultra-luminous X-ray pulsars

    CERN Document Server

    Kawashima, Tomohisa; Ohsuga, Ken; Ogawa, Takumi

    2016-01-01

    Prompted by the recent discovery of pulsed emission from an ultra-luminous X-ray source, M82 X-2 ("ULX-pulsar"), we perform a two-dimensional radiation-hydrodynamic simulation of a super-critical accretion flow onto a neutron star through a narrow accretion column. We set an accretion column with a cone shape filled with tenuous gas with density of $10^{-4} {\\rm g}~ {\\rm cm}^{-3}$ above a neutron star and solve the two dimensional gas motion and radiative transfer within the column. The side boundaries are set such that radiation can freely escape, while gas cannot. Since the initial gas layer is not in a hydrostatic balance, the column gas falls onto the neutron-star surface, thereby a shock being generated. As a result, the accretion column is composed of two regions: an upper, nearly free-fall region and a lower settling region, as was noted by Basko \\& Sunyaev (1976). The average accretion rate is very high; ${\\dot M}\\sim 10^{2-3} L_{\\rm E}/c^2$ (with $L_{\\rm E}$ being the Eddington luminosity), and s...

  6. Aactor GT - Development of an inverse gas-turbine that uses renewable energy sources and industrial waste heat - Phase 2; Aactor GT - Entwicklung einer Inversen Gasturbine 'Aactor' zur Nutzung erneuerbarer Energie und industrieller Abwaerme. Phase 2 - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, M.

    2009-09-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of the second phase of the development of a small-scale gas turbine that can use lean gas. The aim of this project phase - the design of a project development unit (PDU) for a micro-turbine with a nominal grid feeding power of 2.4 kWe is discussed. Parallel to this work, peripheral components such as burner and recovery device shall also be designed, produced and tested in the laboratories of the Swiss Center for Appropriate Technology and Social Ecology. The burner is specially designed for the combustion of lean gases. The goals of the following project phase, including the production and field-testing of the unit are discussed. On the basis of this PDU, a prototype lean gas micro-turbine with 9 kWe electrical generation power is to be derived. Project goals, work done and results obtained are reviewed, as is further work to be done.

  7. Extension of the system constants database for open-tubular columns: system maps at low and intermediate temperatures for four new columns.

    Science.gov (United States)

    Atapattu, Sanka N; Eggers, Kimberly; Poole, Colin F; Kiridena, Waruna; Koziol, Wladyslaw W

    2009-03-06

    The solvation parameter model is used to characterize the separation properties of four open-tubular columns for gas chromatography at low and intermediate column temperatures covering the range 60-240 degrees C. Solute descriptors for compounds suitable for characterizing columns over the intermediate temperature range are optimized using an iterative procedure. These compounds, and those previously recommended for the lower temperature range, are used to provide system constant maps for Rxi-5Sil MS, Rxi-17, Rtx-TNT and Rtx-TNT2 columns suitable for merging with a system constants database with entries for more than 50 columns. The Rxi-5Sil MS column is shown to have separation properties similar to the silphenylene-dimethylsiloxane copolymer stationary phase (DB-5ms) but these two columns are not selectivity equivalent. The Rxi-17 column has similar separation properties to the Rxi-50 column but is not selectivity equivalent to it. Rxi-17 is a poly(dimethyldiphenylsiloxane) stationary phase containing 50% diphenylsiloxane monomer and Rxi-50 a poly(methylphenylsiloxane) stationary phase with the same nominal composition but a different monomer structure. The difference in monomer structure results in only small changes in selectivity, and for all but the most demanding separations, the columns are interchangeable. The application-specific column (energetic materials) Rtx-TNT is shown to be selectivity equivalent to columns coated with the poly(dimethyldiphenylsiloxane) stationary phases containing 5% diphenylsiloxane monomer. The Rtx-TNT2 column is selectivity equivalent to the proprietary Rtx-OPPesticides column. Rtx-OPPesticides is a low bleed stationary phase, possibly based on silarylene-siloxane chemistry, with a composition designed to mimic the separation properties of the poly(dimethylmethyltrifluoropropylsiloxane) stationary phases containing 35% methyltrifluoropropylsiloxane monomer. Selectivity equivalence of columns is determined by the statistical

  8. Calibration of the Total Carbon Column Observing Network using aircraft profile data

    Directory of Open Access Journals (Sweden)

    D. Wunch

    2010-10-01

    Full Text Available The Total Carbon Column Observing Network (TCCON produces precise measurements of the column average dry-air mole fractions of CO2, CO, CH4, N2O and H2O at a variety of sites worldwide. These observations rely on spectroscopic parameters that are not known with sufficient accuracy to compute total columns that can be used in combination with in situ measurements. The TCCON must therefore be calibrated to World Meteorological Organization (WMO in situ trace gas measurement scales. We present a calibration of TCCON data using WMO-scale instrumentation aboard aircraft that measured profiles over four TCCON stations during 2008 and 2009. These calibrations are compared with similar observations made in 2004 and 2006. The results indicate that a single, global calibration factor for each gas accurately captures the TCCON total column data within error.

  9. Improved Thermal Modulator for Gas Chromatography

    Science.gov (United States)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  10. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas; Aldén, Marcus; Li, Zhongshan, E-mail: zhongshan.li@forbrf.lth.se, E-mail: alpers@ma.tum.de [Division of Combustion Physics, Lund University, P.O. Box 118, S-221 00 Lund (Sweden); Moseev, Dmitry [Max-Planck-Institut für Plasmaphysik, D-85748 Garching bei München (Germany); FOM Institute DIFFER, 3430 BE Nieuwegein (Netherlands); Kusano, Yukihiro [Department of Wind Energy, Section for Composites and Materials Mechanics, Technical University of Denmark, Risø Campus, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Salewski, Mirko [Department of Physics, Section for Plasma Physics and Fusion Energy, Technical University of Denmark, DK-2800 Kongens Lyngby (Denmark); Alpers, Andreas, E-mail: zhongshan.li@forbrf.lth.se, E-mail: alpers@ma.tum.de; Gritzmann, Peter; Schwenk, Martin [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany)

    2015-01-26

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

  11. Gas Chromatography

    Science.gov (United States)

    Qian, Michael C.

    Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.

  12. The Inverse Problem for the Dipole Field

    CERN Document Server

    Epp, V

    2015-01-01

    The Inverse problem for an electromagnetic field produced by a dipole is solved. It is assumed that the field of an arbitrary changing dipole is known. Obtained formulae allow calculation of the position and dynamics of the dipole which produces the measured field. The derived results can be used in investigations on radiative process in solids caused by changing of the charge distribution. For example, generation of the electromagnetic field caused by oscillations of atoms or electron gas at the trace of a particle channeling in a crystal, or fields arising at solids cracking or dislocation formation -- in any case when one is interested in the details of the dipole field source.

  13. Integrated inversion using combined wave-equation tomography and full waveform inversion

    Science.gov (United States)

    Wang, Haiyang; Singh, Satish C.; Calandra, Henri

    2014-07-01

    Wave-equation tomography (WT) and full waveform inversion (FWI) are combined through a hybrid misfit function to estimate high-resolution subsurface structures starting from a poorly constrained initial velocity model. Both methods share the same wavefield forward modelling and inversion schemes, while they differ only on the ways to calculate misfit functions and hence the ways to sample in the model space. Aiming at minimizing the cross-correlation phase delay between synthetic and real data, WT can be used to retrieve the long- and middle-wavelength model components, which are essential to FWI. Compared to ray-based traveltime tomography that is based on asymptotic high-frequency approximation, WT provides a better resolution by exploring the band-limited feature of seismic wavefield. On the other hand, FWI is capable of resolving the short-wavelength model component, complementing the WT. In this study, we apply WT to surface first-arrival refraction data, and apply FWI to both refraction and reflection data. We assign adaptive weights to the two different misfit measurements and build a progressive inversion strategy. To illustrate the advantage of our strategy over conventional `ray tomography + FWI' approach, we show in a synthetic lens test that WT can provide extra subsurface information that is critical for a successful FWI application. To further show the efficiency, we test our strategy on the 2-D Marmousi model where satisfactory inversion results are achieved without much manual intervention. Finally, we apply the inversion strategy to a deep-water seismic data set acquired offshore Sumatra with a 12-km-long streamer. In order to alleviate several practical problems posed by the deep-water setting, we apply downward continuation (DC) to generate a virtual ocean bottom experiment data set prior to inversion. The new geometry after DC boosts up the shallow refractions, as well as avoiding cumbersome modelling through the thick water column, thus

  14. Multi-Column Experimental Test Bed Using CaSDB MOF for Xe/Kr Separation

    Energy Technology Data Exchange (ETDEWEB)

    Welty, Amy Keil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Greenhalgh, Mitchell Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Garn, Troy Gerry [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    Processing of spent nuclear fuel produces off-gas from which several volatile radioactive components must be separated for further treatment or storage. As part of the Off-gas Sigma Team, parallel research at INL and PNNL has produced several promising sorbents for the selective capture of xenon and krypton from these off-gas streams. In order to design full-scale treatment systems, sorbents that are promising on a laboratory scale must be proven under process conditions to be considered for pilot and then full-scale use. To that end, a bench-scale multi-column system with capability to test multiple sorbents was designed and constructed at INL. This report details bench-scale testing of CaSDB MOF, produced at PNNL, and compares the results to those reported last year using INL engineered sorbents. Two multi-column tests were performed with the CaSDB MOF installed in the first column, followed with HZ-PAN installed in the second column. The CaSDB MOF column was placed in a Stirling cryocooler while the cryostat was employed for the HZ-PAN column. Test temperatures of 253 K and 191 K were selected for the first column while the second column was held at 191 K for both tests. Calibrated volume sample bombs were utilized for gas stream analyses. At the conclusion of each test, samples were collected from each column and analyzed for gas composition. While CaSDB MOF does appear to have good capacity for Xe, the short time to initial breakthrough would make design of a continuous adsorption/desorption cycle difficult, requiring either very large columns or a large number of smaller columns. Because of the tenacity with which Xe and Kr adhere to the material once adsorbed, this CaSDB MOF may be more suitable for use as a long-term storage solution. Further testing is recommended to determine if CaSDB MOF is suitable for this purpose.

  15. Elastic stability of non-uniform columns

    Science.gov (United States)

    Lee, S. Y.; Kuo, Y. H.

    1991-07-01

    A simple and efficient method is proposed to investigate the elastic stability of three different tapered columns subjected to uniformly distributed follower forces. The influences of the boundary conditions and taper ratio on critical buckling loads are investigated. The critical buckling loads of columns of rectangular cross section with constant depth and linearly varied width ( T1), constant width and linearly varied depth ( T2) and double taper ( T3) are investigated. Among the three different non-uniform columns considered, taper ratio has the greatest influence on the critical buckling load of column T3 and the lowest influence on that of column T1. The types of instability mechanisms for hinged-hinged and cantilever non-uniform columns are divergence and flutter respectively. However, for clamped-hinged and clamped-clamped non-uniform columns, the type of instability mechanism for column T1 is divergence, while that for columns T2 and T3 is divergence only when the taper ratio of the columns is greater than certain critical values and flutter for the rest value of taper ratio. When the type of instability mechanism changes from divergence to flutter, there is a finite jump for the critical buckling load. The influence of taper ratio on the elastic stability of cantilever column T3 is very sensitive for small values of the taper ratio and there also exist some discontinieties in the critical buckling loads of flutter instability. For a hinged-hinged non-uniform column ( T2 or T3) with a rotational spring at the left end of the column, when the taper ratio is less than the critical value the instability mechanism changes from divergence to flutter as the rotational spring constant is increased. For a clamped-elastically supported non-uniform column, when the taper ratio is greater than the critical value the instability mechanism changes from flutter to divergence as the translational spring constant is increased.

  16. Dark Radiative Inverse Seesaw

    CERN Document Server

    Ahriche, Amine; Nasri, Salah

    2016-01-01

    We present a minimal model that simultaneously accounts for neutrino masses and the origin of dark matter (DM) and where the electroweak phase transition is strong enough to allow for electroweak baryogenesis. The Standard Model is enlarged with a Majorana fermion, three generations of chiral fermion pairs, and a single complex scalar that plays a central role in DM production and phenomenology, neutrino masses, and the strength of the phase transition. All the new fields are singlets under the SM gauge group. Neutrino masses are generated via a new variant of radiative inverse seesaw where the required small mass term is generated via loops involving DM and no large hierarchy is assumed among the mass scales. The model offers all the advantage of low-scale neutrino mass models as well as a viable dark matter candidate that is testable with direct detection experiments.

  17. Inverse Queries For Multidimensional Spaces

    CERN Document Server

    Bernecker, Thomas; Kriegel, Hans-Peter; Mamoulis, Nikos; Renz, Matthias; Zhang, Shiming; Züfle, Andreas

    2011-01-01

    Traditional spatial queries return, for a given query object $q$, all database objects that satisfy a given predicate, such as epsilon range and $k$-nearest neighbors. This paper defines and studies {\\em inverse} spatial queries, which, given a subset of database objects $Q$ and a query predicate, return all objects which, if used as query objects with the predicate, contain $Q$ in their result. We first show a straightforward solution for answering inverse spatial queries for any query predicate. Then, we propose a filter-and-refinement framework that can be used to improve efficiency. We show how to apply this framework on a variety of inverse queries, using appropriate space pruning strategies. In particular, we propose solutions for inverse epsilon range queries, inverse $k$-nearest neighbor queries, and inverse skyline queries. Our experiments show that our framework is significantly more efficient than naive approaches.

  18. CO2 variability from in situ and vertical column measurements in Mexico City

    Science.gov (United States)

    Baylon, J. L.; Grutter, M.; Stremme, W.; Bezanilla, A.; Plaza, E.

    2014-12-01

    UNAM started a program to measure, among many other atmospheric parameters, greenhouse gas concentrations at six stations in the Mexican territory as part of the "Red Universitaria de Observatorios Atmosfericos", RUOA (www.ruoa.unam.mx). In this work we present recent time series of CO2 measured at the station located in the university campus in Mexico City, and compare them to total vertical columns of this gas measured at the same location. In situ measurements are continuously carried out with a cavity ring-down spectrometer (Picarro Inc., G2401) since July 2014 and the columns are retrieved from solar absorption measurements taken with a Fourier transform infrared spectrometer (Bruker, Vertex 80) when conditions allow. The retrieval method is described and results of the comparison of both techniques and a detailed analysis of the variability of this important greenhouse gas is presented. Simultaneous surface and column CO2 data are useful to constrain models and estimate emissions.

  19. Control of packed column fouling in the continuous fermentation and stripping of ethanol.

    Science.gov (United States)

    Taylor, F; Kurantz, M J; Goldberg, N; Craig, J C

    1996-07-05

    By recycling the contents of a 14 L fermentor through a stripping column to continuously remove ethanol and reduce product inhibition, continuous complete conversion of nutrient feed containing 600 g/L glucose was achieved in a small pilot plant. Ethanol was recovered from the carbon dioxide stripping gas in a refrigerated condenser, and the gas was reheated with steam and recycled by a blower. Productivity of ethanol in the fermentor as high as 15.8 g/L/h and condensate production of up to 10 L/day of almost 50% by volume ethanol were maintained for up to 60 days of continuous operation. Weekly washing of the column packing in situ was required to prevent loss of performance caused by attached growth of yeast cells, which restricts the gas flow rate through the stripping column. (c) 1996 John Wiley & Sons, Inc.

  20. Temperature of Steel Columns under Natural Fire

    Directory of Open Access Journals (Sweden)

    F. Wald

    2004-01-01

    Full Text Available Current fire design models for time-temperature development within structural elements as well as for structural behaviour are based on isolated member tests subjected to standard fire regimes, which serve as a reference heating, but do not model natural fire. Only tests on a real structure under a natural fire can evaluate future models of the temperature developments in a fire compartment, of the transfer of heat into the structure and of the overall structural behaviour under fire.To study overall structural behaviour, a research project was conducted on an eight storey steel frame building at the  Cardington Building Research Establishment laboratory on January 16, 2003. A fire compartment 11×7 m was prepared on the fourth floor. A fire load of 40 kg/m2 was applied with 100 % permanent mechanical load and 65 % of imposed load. The paper summarises the experimental programme and shows the temperature development of the gas in the fire compartment and of the fire protected columns bearing the unprotected floors.

  1. World Natural Gas Model

    Energy Technology Data Exchange (ETDEWEB)

    1994-12-01

    RAMSGAS, the Research and Development Analysis Modeling System World Natural Gas Model, was developed to support planning of unconventional gaseoues fuels research and development. The model is a scenario analysis tool that can simulate the penetration of unconventional gas into world markets for oil and gas. Given a set of parameter values, the model estimates the natural gas supply and demand for the world for the period from 1980 to 2030. RAMSGAS is based on a supply/demand framwork and also accounts for the non-renewable nature of gas resources. The model has three fundamental components: a demand module, a wellhead production cost module, and a supply/demand interface module. The demand for gas is a product of total demand for oil and gas in each of 9 demand regions and the gas share. Demand for oil and gas is forecast from the base year of 1980 through 2030 for each demand region, based on energy growth rates and price-induced conservation. For each of 11 conventional and 19 unconventional gas supply regions, wellhead production costs are calculated. To these are added transportation and distribution costs estimates associated with moving gas from the supply region to each of the demand regions and any economic rents. Based on a weighted average of these costs and the world price of oil, fuel shares for gas and oil are computed for each demand region. The gas demand is the gas fuel share multiplied by the total demand for oil plus gas. This demand is then met from the available supply regions in inverse proportion to the cost of gas from each region. The user has almost complete control over the cost estimates for each unconventional gas source in each year and thus can compare contributions from unconventional resources under different cost/price/demand scenarios.

  2. Liquid-Phase Back mixing in Bubble Columns

    Directory of Open Access Journals (Sweden)

    Burhan S. Abdulrazak

    2013-05-01

    Full Text Available Liquid-phase axial dispersion coefficients have been measured for air-water system in bubble columns of 10, 15 and 30 cm diameter. The experiments are carried out using a transient method (the tracer response method.  Dispersion coefficient is obtained by adjusting the experimental profiles of tracer concentration with the predictions of the model. The experimental results show that one-dimensional axial dispersion coefficient, Dax,L, reveal strong scale dependence. Backmixing of liquid phase increases with the increase of reactor diameter and superficial gas velocity.  Axial dispersion coefficient for large column reactors can be easily predicted from the developed relation . Comparison of calculated with the experimental data and with the published data of other authors shows good agreement which ensure the reliability and confusability of the adopted correlations to be used in further design and scale-up purposes. 

  3. Anaerobic digestion of dairy wastewater by inverse fluidization: the inverse fluidized bed and the inverse turbulent bed reactors

    Energy Technology Data Exchange (ETDEWEB)

    Arnaiz, C.; Buffiere, P.; Elmaleh, S.; Lebrato, J.; Moletta, R.

    2003-11-01

    This paper describes the application of the inverse fluidization technology to the anaerobic digestion of dairy wastewater. Two reactors were investigated: the inverse fluidized bed reactor and the inverse turbulent reactor. In these reactors, a granular floating solid is expanded by a down-flow current of effluent or an up-flow current of gas, respectively. The carrier particles (Extendospheres) were chosen for their large specific surface area (20,000 m{sup 2} m{sup -3}) and their low energy requirements for fluidization (gas velocity of 1.5 mm s{sup -1}, 5.4 m h{sup -1}). Organic load was increased stepwise by reducing hydraulic retention time from more than 60 days to 3 days, while maintaining constant the feed COD concentration. Both reactors achieved more than 90% of COD removal, at an organic loading rate of 10-12 kg{sub COD} m{sup -3} d{sup -1}, respectively. The performances observed were similar or even higher than that of other previously tested fluidized bed technologies treating the same wastewater. It was found that the main advantages of this system are: low energy requirement, because of the low fluidization velocities required; there is no need of a settling device, because solids accumulate at the bottom of the reactor, so they can be easily drawn out and particles with high-biomass content can be easily recovered. Lipid phosphate concentration has been revealed as a good method for biomass estimation in biofilms since it only includes living biomass. (Author)

  4. Produced fluids separation using a coalascer column

    Energy Technology Data Exchange (ETDEWEB)

    Renouf, G.; Soveran, D.; Soveran, L. [Saskatchewan Research Council, Saskatoon, SK (Canada)

    2005-07-01

    This paper reports the results of a laboratory study in which a coalescer column was used to successfully remove water from produced heavy oil emulsions. The coalescer column is a simple, inexpensive, and environmentally friendly technology that can improve basic sediment and water values after 4 hours of settling time by about 38 per cent. The laboratory study tested the use of the column, and the effects of column length, column packing size, temperature, flow rate, demulsifier concentration, and water addition. More than 100 tests were conducted and 24 pairs of tests compared the treating effects with and without the column. The use of the coalescer column in the treatment facility resulted in a a reduction of demulsifier concentration from 250 ppm to 70 ppm, translating to an annual cost savings of $320,000 to $1,100,000 per battery. Incorporating the coalescer column also allowed operators to reduce both temperatures and demulsifier concentrations. The column also promoted faster treating. Water droplets grew by as much as 34 per cent, suggesting that treating time could be faster by 21 to 80 per cent. It was concluded that the coalescer column was very successful at improving water removal from heavy oil battery emulsions. 22 refs., 9 tabs., 7 figs.

  5. Approximation Theorems of Moore-Penrose Inverse by Outer Inverses

    Institute of Scientific and Technical Information of China (English)

    Qianglian Huang; Zheng Fang

    2006-01-01

    Let X and Y be Hilbert spaces and T a bounded linear operator from X into Y with a separable range. In this note, we prove, without assuming the closeness of the range of T, that the Moore-Penrose inverse T+ of T can be approximated by its bounded outer inverses T#n with finite ranks.

  6. Column flotation testing at Suncor Energy Inc.

    Energy Technology Data Exchange (ETDEWEB)

    Cleyle, P.; Lee, L. [Suncor Energy Inc. Oil Sands, Fort McMurray, AB (Canada)

    2006-07-01

    The operations at Suncor's primary extraction plant were reviewed with reference to the column flotation process and the history of column flotation testing at Suncor. Tertiary bitumen recovery processes were also reviewed. In March and August 2005, an in-plant pilot scale column flotation test was conducted at Suncor's Millennium Primary Extraction plant near Fort McMurray, Alberta. The purpose was to evaluate the feasibility of using column flotation for tertiary bitumen recovery from cyclone overflow. The test was performed in a 4 ft diameter by 25 ft high column to determine the effects of column feed flow rate, froth wash water supply, and froth depth. The feed ranged from 0.14 to 3.79 wt per cent bitumen. Feed flow rate ranged from 59 to 237 USGPM. The test results indicated that wash water reduced froth mineral content. Increasing the wash water did not make any difference in mineral rejection. Although bitumen upgrading improved when the test column was operated at a deeper froth depth, the mineral content was not reduced. Both mechanical cell and flotation column tailings samples were collected in the flotation column tests. The average tailings composition for the last cell in the tertiary mechanical bank was 0.22 per cent bitumen, 12.10 per cent mineral, and 87.66 per cent water. At an average test column feed rate of 158 USGPM, the average tailings composition was 0.23 per cent bitumen, 12.13 per cent mineral, and 87.62 per cent water. It was concluded that flotation columns are capable of producing a tailings product similar to that of the tertiary mechanical bank. Therefore, it is feasible to use flotation columns as an alternative to mechanical cells. In fact, since there are no rotating parts requiring off-line maintenance work, flotation columns may be a better alternative from a maintenance and operations perspective. tabs., figs.

  7. X-ray laser experiments by using a gas puff target with the ASTERIX IV facility

    Energy Technology Data Exchange (ETDEWEB)

    Fiedorowicz, H.; Bartnik, A.; Fill, E.; Li, Y.; Pretzler, G.; Szczurek, M. [Institute of Optoelectronics, Military University of Technology, Warsaw (Poland)

    1996-05-01

    We report the first X-ray laser experiments with the use of laser-irradiated gas puff targets. The targets, produced by pulsed injection of a small amount of gas from a high-pressure solenoid valve through a nozzle in a form of a slit, has been characterized by optical interferometry and X-ray backlighting. The formation of elongated hot plasma columns up to 30-mm long is demonstrated. The spatial uniformity of the column was monitored by means of an X-ray pinhole camera. XUV spectra measurements for SF{sub 6} gas puff targets show predominant 3{endash}2 line of hydrogenic fluorine ({lambda}=8.1 nm), however, only linear increasing of its intensity with the target length was observed. An inversion on the lithium-like 4{ital d}-3{ital p} line can be inferred from the relative intensities of the Li-like resonance lines. Results for Kr target indicate that the plasma temperature was too low to create Ne-like ions. {copyright} {ital 1996 American Institute of Physics.}

  8. Sum of ranking differences to rank stationary phases used in packed column supercritical fluid chromatography.

    Science.gov (United States)

    West, Caroline; Khalikova, Maria A; Lesellier, Eric; Héberger, Károly

    2015-08-28

    The identification of a suitable stationary phase in supercritical fluid chromatography (SFC) is a major source of difficulty for those with little experience in this technique. Several protocols have been suggested for column classification in high-performance liquid chromatography (HPLC), gas chromatography (GC), and SFC. However, none of the proposed classification schemes received general acceptance. A fair way to compare columns was proposed with the sum of ranking differences (SRD). In this project, we used the retention data obtained for 86 test compounds with varied polarity and structure, analyzed on 71 different stationary phases encompassing the full range in polarity of commercial packed columns currently available to the SFC chromatographer, with a single set of mobile phase and operating conditions (carbon dioxide-methanol mobile phase, 25°C, 150bar outlet pressure, 3ml/min). First, a reference column was selected and the 70 remaining columns were ranked based on this reference column and the retention data obtained on the 86 analytes. As these analytes previously served for the calculation of linear solvation energy relationships (LSER) on the 71 columns, SRD ranks were compared to LSER methodology. Finally, an external comparison based on the analysis of 10 other analytes (UV filters) related the observed selectivity to SRD ranking. Comparison of elution orders of the UV filters to the SRD rankings is highly supportive of the adequacy of SRD methodology to select similar and dissimilar columns.

  9. Oscillating water column structural model

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, Guild [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bull, Diana L [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jepsen, Richard Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gordon, Margaret Ellen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    An oscillating water column (OWC) wave energy converter is a structure with an opening to the ocean below the free surface, i.e. a structure with a moonpool. Two structural models for a non-axisymmetric terminator design OWC, the Backward Bent Duct Buoy (BBDB) are discussed in this report. The results of this structural model design study are intended to inform experiments and modeling underway in support of the U.S. Department of Energy (DOE) initiated Reference Model Project (RMP). A detailed design developed by Re Vision Consulting used stiffeners and girders to stabilize the structure against the hydrostatic loads experienced by a BBDB device. Additional support plates were added to this structure to account for loads arising from the mooring line attachment points. A simplified structure was designed in a modular fashion. This simplified design allows easy alterations to the buoyancy chambers and uncomplicated analysis of resulting changes in buoyancy.

  10. Comparison of near surface and column-integrated atmospheric aerosol optical properties

    Science.gov (United States)

    Aryal, Rudra Prasad

    Optical and chemical properties of size-resolved aerosols in near-surface air at Tudor Hill, Bermuda were measured between July 2006 and June 2009. Vertical distributions of aerosol backscattering and column-averaged aerosol optical properties were characterized with a Micro-pulse lidar (MPL) and a CIMEL automated sun-sky radiometer. The chemical species in size-segregated aerosols in marine air were compared with the surface level aerosol optical properties. The aerosol concentration, along with chemical components, was compared with the surface level wind speed and showed a significant correlation with the sea salt components. The non-sea salt components such as non-sea salt sulfate and ammonium did not show a correlation with the surface level wind speed. A comparison between scattering data at surface level with the extinction coefficient at the lowest altitude bin (75m) from the lidar inversion shows a consistent correlation but is quantitatively different. This quantitative discrepancy was explained based on the hygroscopic growth due to differences in relative humidity in measurement conditions. Aerosol optical properties measured near the surface were often significantly correlated with those averaged over the column. These include scattering by near-surface bulk aerosol at 530 nm versus column aerosol optical depth (AOD), near-surface sub-microm scattering fraction versus column averaged sub-microm scattering fraction, and the average angstrom exponent over column and lidar ratio derived using column integrated size distribution and complex refractive index. We also found that the single scattering albedo (ω o) measured at the surface by combining daily averages of the aerosol absorption and aerosol light scattering were in the same range as the instantaneous ω o retrieved for the column. The relative contribution of submicron aerosol light scattering to total aerosol light scattering is slightly higher in the column relative to the surface. Surface

  11. Study on a continuous heat integrated distillation column

    Energy Technology Data Exchange (ETDEWEB)

    Glenchur, T.; Govind, R.

    1987-12-01

    A novel continuous heat integrated distillation column called a concentric column has been studied using computer simulation. It is shown that a concentric column is a novel implementation of a thermodynamically reversible distillation column and has a lower energy loss than an ordinary distillation column. Their studies show that a concentric column has reduced column height, since the stripping section is configured concentrically around the rectifying section, and uses less utilities than a conventional column.

  12. Formaldehyde (HCHO) column measurements from airborne instruments: Comparison with airborne in-situ measurements, model, and satellites

    Science.gov (United States)

    Kwon, Hyeong-Ahn; Park, Rokjin; Nowlan, Caroline; González Abad, Gonzalo; Chance, Kelly; Janz, Scott

    2017-04-01

    Trace gas measurements from airborne instruments are useful to evaluate and improve a retrieval algorithm developed for the Geostationary Environment Monitoring Spectrometer (GEMS). We used radiances measured from two airborne 2D array sensors, the GeoCAPE Airborne Simulator (GCAS) and the Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) for DISCOVER-AQ Texas in 2013 and for KORUS-AQ in 2016 to retrieve formaldehyde (HCHO) columns and to evaluate the GEMS retrieval algorithm. In addition, we used simulated aerosol concentrations constrained by airborne LIDAR observations for AMF calculation to convert slant columns to vertical columns. We compared retrieved HCHO columns with vertical columns obtained from in-situ airborne HCHO measurements. Optical properties and distributions of aerosols are found to be important factors, affecting HCHO retrievals. Finally, additional comparisons of retrieved results with model simulations and low-orbiting satellites provides quantitative information for improving bottom-up emission estimates of volatile organic carbon emissions.

  13. The jet flotation column control system

    Energy Technology Data Exchange (ETDEWEB)

    Xu Zhiqiang; Ming Shangzhi; Liu Lijian; Huangfu Jinghua; Huo Sen; Zhang Rongzeng [China Univ. of Mining and Technology, Beijing (China). Mineral Processing Dept.; Yang Hongjun [Hebi Coal Mine Administrative (China)

    1998-12-31

    Compared with the conventional mechanical flotation column, the jet flotation column has the advantages of high selectivity of separation, low investment and production cost, low floor space requirement, low dosage of reagent, easy control; it is more suitable to process fine particles. Recently, many new types of flotation columns have been developed with new methods. Mineral Processing Dept., China University of Mining and Technology (Beijing) designed an aerated, double-jet flotation column in the lab and the industrial trial will be put into operation. One of the significant characteristics of the new type of flotation column is high selectivity of separation, fast bubble mineralization speed. As it is sensitive to various factors, a control system for flotation column has been developed to stabilize the working condition, and this set of control system has been operated in the lab experiment.

  14. Multiples waveform inversion

    KAUST Repository

    Zhang, D. L.

    2013-01-01

    To increase the illumination of the subsurface and to eliminate the dependency of FWI on the source wavelet, we propose multiples waveform inversion (MWI) that transforms each hydrophone into a virtual point source with a time history equal to that of the recorded data. These virtual sources are used to numerically generate downgoing wavefields that are correlated with the backprojected surface-related multiples to give the migration image. Since the recorded data are treated as the virtual sources, knowledge of the source wavelet is not required, and the subsurface illumination is greatly enhanced because the entire free surface acts as an extended source compared to the radiation pattern of a traditional point source. Numerical tests on the Marmousi2 model show that the convergence rate and the spatial resolution of MWI is, respectively, faster and more accurate then FWI. The potential pitfall with this method is that the multiples undergo more than one roundtrip to the surface, which increases attenuation and reduces spatial resolution. This can lead to less resolved tomograms compared to conventional FWI. The possible solution is to combine both FWI and MWI in inverting for the subsurface velocity distribution.

  15. Inverse problem in hydrogeology

    Science.gov (United States)

    Carrera, Jesús; Alcolea, Andrés; Medina, Agustín; Hidalgo, Juan; Slooten, Luit J.

    2005-03-01

    The state of the groundwater inverse problem is synthesized. Emphasis is placed on aquifer characterization, where modelers have to deal with conceptual model uncertainty (notably spatial and temporal variability), scale dependence, many types of unknown parameters (transmissivity, recharge, boundary conditions, etc.), nonlinearity, and often low sensitivity of state variables (typically heads and concentrations) to aquifer properties. Because of these difficulties, calibration cannot be separated from the modeling process, as it is sometimes done in other fields. Instead, it should be viewed as one step in the process of understanding aquifer behavior. In fact, it is shown that actual parameter estimation methods do not differ from each other in the essence, though they may differ in the computational details. It is argued that there is ample room for improvement in groundwater inversion: development of user-friendly codes, accommodation of variability through geostatistics, incorporation of geological information and different types of data (temperature, occurrence and concentration of isotopes, age, etc.), proper accounting of uncertainty, etc. Despite this, even with existing codes, automatic calibration facilitates enormously the task of modeling. Therefore, it is contended that its use should become standard practice. L'état du problème inverse des eaux souterraines est synthétisé. L'accent est placé sur la caractérisation de l'aquifère, où les modélisateurs doivent jouer avec l'incertitude des modèles conceptuels (notamment la variabilité spatiale et temporelle), les facteurs d'échelle, plusieurs inconnues sur différents paramètres (transmissivité, recharge, conditions aux limites, etc.), la non linéarité, et souvent la sensibilité de plusieurs variables d'état (charges hydrauliques, concentrations) des propriétés de l'aquifère. A cause de ces difficultés, le calibrage ne peut êtreséparé du processus de modélisation, comme c'est le

  16. Inverse problems for Maxwell's equations

    CERN Document Server

    Romanov, V G

    1994-01-01

    The Inverse and Ill-Posed Problems Series is a series of monographs publishing postgraduate level information on inverse and ill-posed problems for an international readership of professional scientists and researchers. The series aims to publish works which involve both theory and applications in, e.g., physics, medicine, geophysics, acoustics, electrodynamics, tomography, and ecology.

  17. Inversion exercises inspired by mechanics

    Science.gov (United States)

    Groetsch, C. W.

    2016-02-01

    An elementary calculus transform, inspired by the centroid and gyration radius, is introduced as a prelude to the study of more advanced transforms. Analysis of the transform, including its inversion, makes use of several key concepts from basic calculus and exercises in the application and inversion of the transform provide practice in the use of technology in calculus.

  18. SNAP-TITE Composite Column Reinforcement

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Recent earthquakes throughout the world have demonstrated the vulnerabilities of older reinforced concrete columns to seismic deformation demands. The Snap Tite Composite Column Reinforcement strengthens a concrete column by confining it in an external composite jacket, which prevents the concrete from expanding during seismic activity or prolonged freeze-thaw cycles. The pre-manufactured fiberglass jacket is comprised of glass fibers and corrosion resistant isopolyester resins.

  19. Parametric resonance in concrete beam-columns

    OpenAIRE

    Sharma,Mamta R.; Singh,Arbind K; Benipal,Gurmail S

    2014-01-01

    A dynamic instability, called parametric resonance, is exhibited by undampedelastic beam-columns when under the action of pulsating axial force. The scope of the existing theory of parametric resonance is restricted to physically linear beam-columns undergoing finite lateral displacements. In this Paper, the dynamic behaviour of physically nonlinear elastic cracked concrete beam-columns under pulsating axial force and constant lateral force is investigated. The constitutive equations derived ...

  20. Multiscale Modelling and Inverse Problems

    CERN Document Server

    Nolen, J; Stuart, A M

    2010-01-01

    The need to blend observational data and mathematical models arises in many applications and leads naturally to inverse problems. Parameters appearing in the model, such as constitutive tensors, initial conditions, boundary conditions, and forcing can be estimated on the basis of observed data. The resulting inverse problems are often ill-posed and some form of regularization is required. These notes discuss parameter estimation in situations where the unknown parameters vary across multiple scales. We illustrate the main ideas using a simple model for groundwater flow. We will highlight various approaches to regularization for inverse problems, including Tikhonov and Bayesian methods. We illustrate three ideas that arise when considering inverse problems in the multiscale context. The first idea is that the choice of space or set in which to seek the solution to the inverse problem is intimately related to whether a homogenized or full multiscale solution is required. This is a choice of regularization. The ...

  1. Continuous absorption of CO2 in packed column using MDEA solution for biomethane preparation

    Science.gov (United States)

    Mindaryani, A.; Budhijanto, W.; Ningrum, S. S.

    2016-11-01

    Nowadays, the energy consumption in Indonesia is increasing. Raising of energy consumption force Indonesia to find other energy resources. Biogas is one of the renewable energy, which was developed in anticipation to the fossil energy reduction. Reducing the content of impurities in biogas may reduce the corrosion impact and increase the combustion efficiency. The biomethane can be utilised as fuel for generator in small and medium scale industries (IKM). Continuous CO2 absorption in packed column using MDEA solution as absorbent is studied for biomethane preparation. CO2 absorption experiments was performed continuously in the packed absorption column with a diameter of 6 cm and 75 cm length. Gas is sparged from the bottom of the column while the liquid is pumped through the top of the column. The concentration of CO2 at exit gas is analysed by GC and recorded as a function of time. The flowrate of the inlet gas was varied at 1 LPM; 1.5 LPM; and 1.8 LPM. Variation of MDEA solution concentration used was 20% and 35.31%. Mathematical model for unsteady state CO2 absorption in packed column was developed. The reaction rate constant (k) and mass transfer coefficient KGa were determined by fitting the outlet CO2 concentration data as a function of time to the model solution with smallest Sum of Square of Errors (SSE). The experimental data shows that absorption of 1 LPM gas flow rate with 0,15 LPM MDEA solution flow rate may reduce 40 % CO2 to be 17 % CO2 in outlet gas. The steady state process reaches at 10 minutes. Increasing gas flow rates shows the higher overall mass transfer coefficient. The reaction rate constant is not affected by gas flow rate variation.

  2. Sediment and water column geochemistry related to methane seepage along the northern US Atlantic margin

    Science.gov (United States)

    Pohlman, J.; Ruppel, C. D.; Colwell, F. S.; Krause, S.; Treude, T.; Graw, M.; Casso, M.; Boze, L. G.; Buczkowski, B.; Brankovits, D.

    2015-12-01

    Many of the more than 550 gas plumes recently identified along the northern US Atlantic margin (USAM) using multibeam water-column backscatter data lie at, or shallower than, the upper limit of gas hydrate stability on the continental slope. Important questions remain unanswered regarding the gas sources feeding these seeps, the export of carbon from the seafloor and the fundamental biogeochemical processes that regulate the flux and transformation of carbon along this margin. In addition, few programs have ever systematically studied the dynamics across the upper slope transition from no hydrate to hydrate. In September 2015, the US Geological Survey, Oregon State University, Geomar and UCLA conducted a multidisciplinary study aboard the R/V Sharp that included piston coring, multicoring, seafloor heat flow measurements, imaging of sub-seafloor sediments and water column methane plumes, and sampling of methane plumes in the water column. This presentation provides some of the basic geochemical results from the cruise, focusing on the pore water characteristics in upper slope gas hydrate provinces that will be used to constrain the fundamental biogeochemical processes operating at methane seeps, including data on the origin of seep methane at sites with and without a possible association with gas hydrate degradation. Water column profiling of methane and other biogeochemically relevant species (e.g., dissolved inorganic and organic carbon) are also used to establish how carbon exported from the seeps affects ocean chemistry and carbon availability in the deep ocean.

  3. Physical inversion of the full IASI spectra: Assessment of atmospheric parameters retrievals, consistency of spectroscopy and forward modelling

    Science.gov (United States)

    Liuzzi, G.; Masiello, G.; Serio, C.; Venafra, S.; Camy-Peyret, C.

    2016-10-01

    Spectra observed by the Infrared Atmospheric Sounder Interferometer (IASI) have been used to assess both retrievals and the spectral quality and consistency of current forward models and spectroscopic databases for atmospheric gas line and continuum absorption. The analysis has been performed with thousands of observed spectra over sea surface in the Pacific Ocean close to the Mauna Loa (Hawaii) validation station. A simultaneous retrieval for surface temperature, atmospheric temperature, H2O, HDO, O3 profiles and gas average column abundance of CO2, CO, CH4, SO2, N2O, HNO3, NH3, OCS and CF4 has been performed and compared to in situ observations. The retrieval system considers the full IASI spectrum (all 8461 spectral channels on the range 645-2760 cm-1). We have found that the average column amount of atmospheric greenhouse gases can be retrieved with a precision better than 1% in most cases. The analysis of spectral residuals shows that, after inversion, they are generally reduced to within the IASI radiometric noise. However, larger residuals still appear for many of the most abundant gases, namely H2O, CH4 and CO2. The H2O ν2 spectral region is in general warmer (higher radiance) than observations. The CO2ν2 and N2O/CO2ν3 spectral regions now show a consistent behavior for channels, which are probing the troposphere. Updates in CH4 spectroscopy do not seem to improve the residuals. The effect of isotopic fractionation of HDO is evident in the 2500-2760 cm-1 region and in the atmospheric window around 1200 cm-1.

  4. Metal-absorption column densities in fast radiative shocks

    OpenAIRE

    Gnat, Orly; Sternberg, Amiel

    2009-01-01

    In this paper we present computations of the integrated metal-ion column densities produced in the post-shock cooling layers behind fast, radiative shock-waves. For this purpose, we have constructed a new shock code that calculates the non-equilibrium ionization and cooling; follows the radiative transfer of the shock self-radiation through the post-shock cooling layers; takes into account the resulting photoionization and heating rates; follows the dynamics of the cooling gas; and self-consi...

  5. Natural gas; Gas Natural

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Carlos A.; Moraes, Claudia C.D. [Eletricidade de Sao Paulo S.A. (ELETROPAULO), Sao Paulo, SP (Brazil); Fonseca, Carlos H.F. [Centrais Eletricas de Santa Catarina S.A., Florianopolis, SC (Brazil); Silva, Clecio Fabricio da; Alves, Ricardo P. [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil); Sposito, Edivaldo Soares; Hulle, Lutero [Espirito Santo Centrais Eletricas S.A. (ESCELSA), Vitoria, ES (Brazil); S. Martins, Icaro da [Centrais Eletricas do Norte do Brasil S.A. (ELETRONORTE), Belem, PA (Brazil); Vilhena, Joao Luiz S. de [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil); Fagundes, Zaluar Aquino [Companhia Estadual de Energia Eletrica do Estado do Rio Grande do Sul, Porto Alegre, RS (Brazil)

    1996-12-31

    An increase in the consumption of natural gas in Brazil is an expected fact in what concerns energetic planning. This work presents the existing situation in what concerns natural gas utilization in the main world economies, as well as an analysis of the participation of this fuel among the energy final consumption per sources. The Brazilian consumption of natural gas is also analysed as well as the international agreement between Brazil and Bolivia for natural gas commercialization. Some legal, institutional and political aspects related to natural gas commercialization are also discussed. Finally, several benefits to be brought by the utilization of natural gas are presented 10 refs., 3 tabs.

  6. Flow patterns in a slurry-bubble-column reactor under reaction conditions

    Energy Technology Data Exchange (ETDEWEB)

    Toselane, B.A.; Brown, D.M.; Zou, B.S.; Dudukovic, M.P. [Washington Univ., St. Louis, MO (United States)

    1995-12-31

    The gas and liquid radioactive tracer response curves obtained in an industrial bubble column reactor of height to diameter ratio of 10 are analyzed and the suitability of the axial dispersion model for interpretation of the results is discussed. The relationship between the tracer concentration distribution and measured detector response of the soluble gas tracer (Ar-41) is possibly dominated by the dissolved gas. The one dimensional axial dispersion model cannot match all the experimental observations well and the flow pattern of the undissolved gas cannot be determined with certainty.

  7. A rainbow inverse problem

    Directory of Open Access Journals (Sweden)

    Calvez V.

    2010-12-01

    Full Text Available We consider the radiative transfer equation (RTE with reflection in a three-dimensional domain, infinite in two dimensions, and prove an existence result. Then, we study the inverse problem of retrieving the optical parameters from boundary measurements, with help of existing results by Choulli and Stefanov. This theoretical analysis is the framework of an attempt to model the color of the skin. For this purpose, a code has been developed to solve the RTE and to study the sensitivity of the measurements made by biophysicists with respect to the physiological parameters responsible for the optical properties of this complex, multi-layered material. On étudie l’équation du transfert radiatif (ETR dans un domaine tridimensionnel infini dans deux directions, et on prouve un résultat d’existence. On s’intéresse ensuite à la reconstruction des paramètres optiques à partir de mesures faites au bord, en s’appuyant sur des résultats de Choulli et Stefanov. Cette analyse sert de cadre théorique à un travail de modélisation de la couleur de la peau. Dans cette perspective, un code à été développé pour résoudre l’ETR et étudier la sensibilité des mesures effectuées par les biophysiciens par rapport aux paramètres physiologiques tenus pour responsables des propriétés optiques de ce complexe matériau multicouche.

  8. GPR Diagnostics of columns in archaeological contexts

    Science.gov (United States)

    Soldovieri, Francesco; Masini, Nicola; Persico, Raffaele; Catapano, Ilaria

    2017-04-01

    columns during a previous work carried out about thirty years ago and whose memory documentation was lost. Both the GPR surveys were carried out by using the K2-RIS IDS system equipped with a high frequency antenna, working at the central frequency of 2GHz. Moreover, the imaging results have been obtained by processing the raw data by means of the end-user friendly software interface designed at the Institute for Electromagnetic Sensing of the Environment - National Research Council of Italy. This interface was some years ago to make possible a simple management of 2D and 3D microwave tomographic approaches based on the Born approximation [4-6].The GPR surveys have confirmed the presence of metallic elements inside few of the investigated columns. [1] Masini N., Nuzzo L., Rizzo E. 2007, GPR investigations for the study and the restoration of the Rose Window of Troia Cathedral (Southern Italy), Near Surface Geophysics, 5 (5), pp. 287-300, doi: 10.3997/1873-0604.2007010 [2] Leucci G., Masini N., Persico R., Soldovieri F. 2011. GPR and sonic tomography for structural restoration: the case of the cathedral of Tricarico, Journal of Geophysics and Engineering, 8 (3), 76-92, doi: 10.1088/1742-2132/8/3/S08 [3] Masini N., Persico R., Rizzo E., Calia A., Giannotta M.T., Quarta G., Pagliuca A. 2010, Integrated Techniques for Analysis and Monitoring of Historical Monuments: the case of S.Giovanni al Sepolcro in Brindisi (Southern Italy), Near Surface Geophysics, 8(5), 423-432, doi:10.3997/1873-0604.2010012 [4] F. Soldovieri, J. Hugenschmidt, R. Persico, G. Leone, A linear inverse scattering algorithm for realistic GPR applications. Near Surf. Geophys. 5(1), 29-42 (2007) [5] I. Catapano, A. Affinito, G. Gennarelli, F.di Maio, A. Loperte, F. Soldovieri, "Full three-dimensional imaging via ground penetrating radar: assessment in controlled conditions and on field for archaeological prospecting", Appl. Phys. A, 2013 [6] I. Catapano, A. Affinito, F. Soldovieri, A user friendly interface

  9. 柱前衍生-气相色谱法同时测定不同柑橘汁中的糖和肌醇(英文)%Simultaneous Determination of Inositols and Carbohydrates in Different Citrus Juices by Gas Chromatography with Pre-column Derivatization

    Institute of Scientific and Technical Information of China (English)

    张耀海; 赵其阳; 张雪莲; 王磊; 焦必宁; 周志钦

    2012-01-01

    A gas chromatographic method using pre-column derivatization was described for the quantitative analysis of fructose,glucose,sucrose,chiro-,scyllo-and myo-inositol in different citrus juices.Juices from different fresh citrus(looseskin mandarin,sweet orange,pummelo,lemon and kumquat) were prepared in the laboratory.Inositols and carbohydrates were analyzed by GC as their oximes derivatives and their identities were confirmed by retention of pure standards.The method was evaluated for precision and recovery using methyl-α-D-glucoside as an internal standard.The recoveries of the method evaluated at two spiked levels were in the range of 98.1%-106.9% with RSDs from 0.6%-6.1%.The limits of detection(LODs) were from 0.29×10-3-0.41×10-3 μg/L(R SN =3).The results support the suitability of the method.The method is simple,quick and reproducible,and applicable to confirm inositols and carbohydrates in different kinds of citrus juice.%为建立柱前衍生-气相色谱技术同时测定不同柑橘汁(宽皮柑橘、甜橙、柚子、柠檬和金柑)中3种肌醇(肌肌醇、鲨肌醇、手性肌醇)和3种可溶性糖(果糖、葡萄糖、蔗糖)的方法,以内标物(甲基-α-D-葡萄糖苷)定量,标准物质的保留时间定性。结果表明:在两个添加水平下,6种成分的平均回收率为98.1%~106.9%,相对标准偏差为0.6%~6.1%,检测限在0.29×10-3~0.41×10-3μg/L(RSN=3)。本方法简便快速,结果准确可靠。

  10. Simultaneous determination of eleven preservatives in food by capillary column-gas chromatography after ultrasound-assisted dispersive liquid-liquid microextraction%超声分散液相微萃取-气相色谱法同时测定食品中11种防腐剂

    Institute of Scientific and Technical Information of China (English)

    杨金玲; 江阳; 薛勇; 孙成均

    2015-01-01

    目的:建立食品中11种防腐剂的超声分散液相微萃取-气相色谱法。方法样品经9∶1二氯甲烷‐乙酸乙酯超声分散液相微萃取,FFAP毛细管色谱柱分离、FID 检测器检测。结果方法线性范围为0.068~400μg/m l ,相关系数为0.9990~0.9999,回收率为84%~122%,相对标准偏差为3.11%~5.83%,方法检出限为0.026~0.23μg/m l。结论该法简便、高效、经济、环境友好,适于不同食品中11种防腐剂同时快速测定。%Objective To establish a method for simultaneous determination of eleven preservatives in foods by gas chromatography after ultrasound‐assisted dispersive liquid-liquid microextraction .Methods The target pre‐servatives in food samples were ultrasound‐assisted dispersive liquid-liquid microextracted ,and then they were separated with FFAP capillary column and detected with FID detector .Results Linear ranges of the method were between 0 .068 and 400μg/mL with correlation coefficients varying from 0 .9990 to 0 .9999 .Recoveries and rela‐tive standard deviations (RSDs)were in the range from 84% to 122% and from 3 .11% to 5 .83% ,respectively . The limitation of detection was in the range form 0 .026μg/ml to 0 .23μg/ml with enrichment factors ranging from 57 to 225 for all target compounds .Conclusion The method is simple ,efficient ,cheap ,eco‐friendly and is suitable for simultaneous determination of 11 preservatives in different foods .

  11. Performance of Inclined Baffle Column for Pectin Continuous Extraction Process from Cocoa Peel (Theobromacacao

    Directory of Open Access Journals (Sweden)

    Soemargono

    2016-01-01

    Full Text Available Pectin from cocoa peel was successfully prepared by extraction method in the bubble column reactor. The process could be carried out in batch and continuous, with co-current or counter current flow. Bubble pipe reactor with inclined baffle is expected to reduce the problem from gas flow patterns, jagged sloping bulkhead serves as a bubble breaker that could replace mechanical stirrer. In this study the reactor column sloping bulkhead was used as extractor to recover pectin in the cocoa peel by citric acid (1 N solvent. Cocoa peel paste and citric acid were entered to the top of the column at 1 : 1 rate ratio by streamed using dosing pump. Nitrogen gas as a medium stirrer flowed counter current from the bottom of the column. Once extraction was completed, the liquid then precipitated by acid alcohol. Pectin solids were washed with alcohol (96%. The temperature of extraction process is maintained at 70° C. The residence time in the column material was determined by feed flow rate (cocoa paste and citric acid, and the volume of suspension that remains in the reactor (V. Residence time equation obtained is: t = (7045.86G-0.1275/L. The yield of yellowish white precipitate reached up to 5.2973% and methoxyl concentration reached 5,21% for 72 minutes. The experiment shows that the continuous extraction process of pectin in baffle columns is better than batch process.

  12. More rational design of bubble columns; Kihoto sekkei no genjo to kadai

    Energy Technology Data Exchange (ETDEWEB)

    Kawase, Y.; Shimizu, K. [Toyo University, Saitama (Japan)

    1998-04-05

    Design and scale-up of bubble columns are not easy even at present. For not the conventional empirical design and scale-up by 1-D dispersion model or vessel line model but more rational approach, simulation is essential. This paper outlines approaches to design and scale-up of bubble columns from the viewpoints of gas dispersion as an important factor for design of bubble columns, and flow analysis of bubble columns. A large part of the design and scale-up of bubble columns is dependent on previous experiences. However, for more precise design and scale-up of bubble columns, those should be conducted through simulation. More precise simulation should be based on simultaneous solution of a motion equation on flow in gas-liquid two-phase system, a diffusion equation of mass transfer including a reaction term, and a heat transmission equation on heat transfer, reducing participation of an empirical correlation equation as much as possible. The importance of simulation will surely increase in the future. 14 refs., 5 figs.

  13. Monthly distribution of diurnal total column ozone based on the 2011 satellite data in Peninsular Malaysia

    Directory of Open Access Journals (Sweden)

    Jasim M. Rajab

    2013-06-01

    Full Text Available Ozone (O3 is a radiatively active trace gas, and naturally present in our atmosphere, that plays a prominent role in atmosphere heating rates due to its good capability to absorb the infrared radiation. O3 occurs both naturally in the Earth’s upper atmosphere and at the ground level. As we breathe the air on Earth, O3 causes damage to the lung tissue and plants as it is an injurious pollutant; it is a major constituent of smog. The atmospheric O3 observations can only be made on global and continental scales by remote sensing instruments situated in the space. The satellite-borne sensor, namely the Atmospheric Infrared Sounder (AIRS included on the EOS Aqua satellite, was employed to investigate the spatial and temporal variations of diurnal total column Ozone burden over Peninsular Malaysia for the year 2011. The analysis of O3 above five dispersed stations in the study area shows the seasonal variation in the O3 fluctuated considerably observed between NEM and SWM seasons. The mean and the standard deviation of monthly O3 was 244.7 ± 26.8 DU for the entire period, and O3 values strongly correlated with weather conditions. The highest O3 values occurred over industrial and congested urban zones (271.5 DU on May at Johor. The lowest O3 values were observed during NEM in the pristine coastal environment on December at Kuantan (217 DU; at 3.45°N, 103.20°E. The O3 has an inverse relationship with the rain and positive with temperature. The monthly O3 maps were obtained from the NASA-operated Giovanni portal (http://disc.sci.gsfc.nasa.gov/giovanni. The AIRS data and the satellite measurements are able to measure the increase of the atmosphere O3 concentrations over different areas.

  14. Column: Factors Affecting Data Decay

    Directory of Open Access Journals (Sweden)

    Kevin Fairbanks

    2012-06-01

    Full Text Available In nuclear physics, the phrase decay rate is used to denote the rate that atoms and other particles spontaneously decompose. Uranium-235 famously decays into a variety of daughter isotopes including Thorium and Neptunium, which themselves decay to others. Decay rates are widely observed and wildly different depending on many factors, both internal and external. U-235 has a half-life of 703,800,000 years, for example, while free neutrons have a half-life of 611 seconds and neutrons in an atomic nucleus are stable.We posit that data in computer systems also experiences some kind of statistical decay process and thus also has a discernible decay rate. Like atomic decay, data decay fluctuates wildly. But unlike atomic decay, data decay rates are the result of so many different interplaying processes that we currently do not understand them well enough to come up with quantifiable numbers. Nevertheless, we believe that it is useful to discuss some of the factors that impact the data decay rate, for these factors frequently determine whether useful data about a subject can be recovered by forensic investigation.(see PDF for full column

  15. Spherical Resorcinol-Formaldehyde Synthesis by Inverse Suspension Polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Ray, Robert J.; Scrivens, Walter A.; Nash, Charles

    2005-10-21

    Base catalyzed sol-gel polycondensation of resorcinol (1,3-dihydroxybenzene) with formaldehyde by inverse suspension polymerization leads to the formation of uniform, highly cross-linked, translucent, spherical gels, which have increased selectivity and capacity for cesium ion removal from high alkaline solutions. Because of its high selectivity for cesium ion, resorcinol-formaldehyde (R-F) resins are being considered for process scale column radioactive cesium removal by ion-exchange at the Waste Treatment and Immobilization Plant (WTP), which is now under construction at the Hanford site. Other specialty resins such as Superlig{reg_sign} 644 have been ground and sieved and column tested for process scale radioactive cesium removal but show high pressure drops across the resin bed during transition from column regeneration to loading and elution. Furthermore, van Deemter considerations indicate better displacement column chromatography by the use of spherical particle beads rather than irregularly shaped ground or granular particles. In our studies batch contact equilibrium experiments using a high alkaline simulant show a definite increase in cesium loading onto spherical R-F resin. Distribution coefficient (Kd) values ranged from 777 to 429 mL/g in the presence of 0.1M and 0.7M potassium ions, respectively. Though other techniques for making R-F resins have been employed, to our knowledge no one has made spherical R-F resins by inverse suspension polymerization. Moreover, in this study we discuss the data comparisons to known algebraic isotherms used to evaluate ion-exchange resins for WTP plant scale cesium removal operations.

  16. Structural model for the dynamic buckling of a column under constant rate compression

    CERN Document Server

    Kuzkin, Vitaly A

    2015-01-01

    Dynamic buckling behavior of a column (rod, beam) under constant rate compression is considered. The buckling is caused by prescribed motion of column ends toward each other with constant velocity. Simple model with one degree of freedom simulating static and dynamic buckling of a column is derived. In the case of small initial disturbances the model yields simple analytical dependencies between the main parameters of the problem: critical force, compression rate, and initial disturbance. It is shown that the time required for buckling is inversely proportional to cubic root of compression velocity and logarithmically depends on the initial disturbance. Analytical expression for critical buckling force as a function of compression velocity is derived. It is shown that in a range of compression rates typical for laboratory experiments the dependence is accurately approximated by a power law with exponent equal to $2/3$. Theoretical findings are supported by available results of laboratory experiments. Keywords...

  17. Multidimensional NMR Inversion without Kronecker Products: Multilinear Inversion

    CERN Document Server

    Medellín, David; Torres-Verdín, Carlos

    2016-01-01

    Multidimensional NMR inversion using Kronecker products poses several challenges. First, kernel compression is only possible when the kernel matrices are separable, and in recent years, there has been an increasing interest in NMR sequences with non-separable kernels. Second, in three or more dimensions, the singular value decomposition is not unique; therefore kernel compression is not well-defined for higher dimensions. Without kernel compression, the Kronecker product yields matrices that require large amounts of memory, making the inversion intractable for personal computers. Finally, incorporating arbitrary regularization terms is not possible using the Lawson-Hanson (LH) or the Butler-Reeds-Dawson (BRD) algorithms. We develop a minimization-based inversion method that circumvents the above problems by using multilinear forms to perform multidimensional NMR inversion without using kernel compression or Kronecker products. The new method is memory efficient, requiring less than 0.1% of the memory required...

  18. Gas arc constriction for plasma arc welding

    Science.gov (United States)

    McGee, William F. (Inventor); Rybicki, Daniel J. (Inventor)

    1994-01-01

    A welding torch for plasma arc welding apparatus has an inert gas applied circumferentially about the arc column externally of the constricting nozzle so as to apply a constricting force on the arc after it has exited the nozzle orifice and downstream of the auxiliary shielding gas. The constricting inert gas is supplied to a plenum chamber about the body of the torch and exits through a series of circumferentially disposed orifices in an annular wall forming a closure at the forward end of the constricting gas plenum chamber. The constricting force of the circumferential gas flow about the arc concentrates and focuses the arc column into a more narrow and dense column of energy after exiting the nozzle orifice so that the arc better retains its energy density prior to contacting the workpiece.

  19. Dust extinction bias in the column density distribution of gamma-ray bursts; high column density, low redshift GRBs are more heavily obscured

    CERN Document Server

    Watson, Darach

    2012-01-01

    The afterglows of gamma-ray bursts (GRBs) have more soft X-ray absorption than expected from the foreground gas column in the Galaxy. While the redshift of the absorption can in general not be constrained from current X-ray observations, it has been assumed that the absorption is due to metals in the host galaxy of the GRB. The large sample of X-ray afterglows and redshifts now available allows the construction of statistically meaningful distributions of the metal column densities. We construct such a sample and show, as found in previous studies, that the typical absorbing column density (N_HX) increases substantially with redshift, with few high column density objects found at low to moderate redshifts. We show, however, that when highly extinguished bursts are included in the sample, using redshifts from their host galaxies, high column density sources are also found at low to moderate redshift. We infer from individual objects in the sample and from observations of blazars, that the increase in column de...

  20. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique...... of existence of measures with given marginals....

  1. Influence of tray hydraulics on tray column

    NARCIS (Netherlands)

    Betlem, Bernardus H.L.; Rijnsdorp, J.E.; Rijnsdorp, J.E.; Azink, R.F.

    1998-01-01

    To column control, in contrast to column design, tray hold-up and dependencies of tray hold-up on the operating conditions play an important role. The essence of this article is the development of an improved model of tray hydraulics over a broad operating range and its experimental validation by

  2. Givental graphs and inversion symmetry

    CERN Document Server

    Dunin-Barkowski, P; Spitz, L

    2012-01-01

    Inversion symmetry is a very non-trivial discrete symmetry of Frobenius manifolds. It was obtained by Dubrovin from one of the elementary Schlesinger transformations of a special ODE associated to Frobenius manifold. In this paper, we review the Givental group action on Frobenius manifolds in terms of Feynman graphs and then we obtain an interpretation of the inversion symmetry in terms of the action of the Givental group. We also consider the implication of this interpretation of the inversion symmetry for the Schlesinger transformations and for the Hamiltonians of the associated principle hierarchy.

  3. Inverse Doppler Effects in Flute

    CERN Document Server

    Zhao, Xiao P; Liu, Song; Shen, Fang L; Li, Lin L; Luo, Chun R

    2015-01-01

    Here we report the observation of the inverse Doppler effects in a flute. It is experimentally verified that, when there is a relative movement between the source and the observer, the inverse Doppler effect could be detected for all seven pitches of a musical scale produced by a flute. Higher tone is associated with a greater shift in frequency. The effect of the inverse frequency shift may provide new insights into why the flute, with its euphonious tone, has been popular for thousands of years in Asia and Europe.

  4. Novel techniques for slurry bubble column hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Dudukovic, M.P.

    1999-05-14

    The objective of this cooperative research effort between Washington University, Ohio State University and Exxon Research Engineering Company was to improve the knowledge base for scale-up and operation of slurry bubble column reactors for syngas conversion and other coal conversion processes by increased reliance on experimentally verified hydrodynamic models. During the first year (July 1, 1995--June 30, 1996) of this three year program novel experimental tools (computer aided radioactive particle tracking (CARPT), particle image velocimetry (PIV), heat probe, optical fiber probe and gamma ray tomography) were developed and tuned for measurement of pertinent hydrodynamic quantities, such as velocity field, holdup distribution, heat transfer and bubble size. The accomplishments were delineated in the First Technical Annual Report. The second year (July, 1996--June 30, 1997) was spent on further development and tuning of the novel experimental tools (e.g., development of Monte Carlo calibration for CARPT, optical probe development), building up the hydrodynamic data base using these tools and comparison of the two techniques (PIV and CARPT) for determination of liquid velocities. A phenomenological model for gas and liquid backmixing was also developed. All accomplishments were summarized in the Second Annual Technical Report. During the third and final year of the program (July 1, 1997--June 30, 1998) and during the nine months no cost extension, the high pressure facility was completed and a set of data was taken at high pressure conditions. Both PIV, CT and CARPT were used. More fundamental hydrodynamic modeling was also undertaken and model predictions were compared to data. The accomplishments for this period are summarized in this report.

  5. Inversion of Array Induction Logs and Its Application

    Institute of Scientific and Technical Information of China (English)

    Gao Jie; Zhao Aibin; Peng Fei; Li Hongqi

    2007-01-01

    With the help of the modified geometrical factor theory, the Marquardt method was used to calculate the true electrical parameters of the formation from array induction logs. The inversion results derived from the assumed model and some practical cases show that the rebuilt formation profile determined by 2-ft resolution array induction logs is reasonable when the formation thickness is greater than 1 m, which thus indicates that the inversion method is reliable and can provide quantitative information for the discrimination of oil/gas or water zone.

  6. COMPARATIVE ANALYSIS OF EXERGETIC BALANCE METHODS IN ALCOHOLIC DISTILLATION COLUMNS

    Directory of Open Access Journals (Sweden)

    Arletis Cruz Llerena

    2017-04-01

    Full Text Available The comparison between three methods to calculate the exergy of the currents involved in the exergetic balance of alcoholic distillation columns is presented. Exergy of the currents was considered as: 1 flow exergies, 2 heat exergies and 3 the sum of flow exergy and chemical exergy. The implementation of the exergetic analysis was examined as a key point to improve the efficiency of the process. A case study, where the methods are applied for the evaluation of the exergy is analyzed; differences among the methods were obtained between the 15% and 30 %. The influence of the studied columns in total work capacity loss was determined, concluding that regardless of the method, the distillation column has shown the higher loss. An economic analysis was made applying the first method to the case study, where the percentage of ethanol in wine increases from 5.8 ºGL to 9 ºGL, which led to a decrease of vapor consumption of 23.66%, an exergetic yield increase of 28.02 % and a combustion gas flow reduction of 24 627 034.4 m3/year.

  7. A Nonlinear Solute Transport Model and Data Reconstruction with Parameter Determination in an Undisturbed Soil-Column Experiment

    Directory of Open Access Journals (Sweden)

    Gongsheng Li

    2011-01-01

    Full Text Available A real undisturbed soil-column infiltrating experiment in Zibo, Shandong, China, is investigated, and a nonlinear transport model for a solute ion penetrating through the column is put forward by using nonlinear Freundlich's adsorption isotherm. Since Freundlich's exponent and adsorption coefficient and source/sink terms in the model cannot be measured directly, an inverse problem of determining these parameters is encountered based on additional breakthrough data. Furthermore, an optimal perturbation regularization algorithm is introduced to determine the unknown parameters simultaneously. Numerical simulations are carried out and then the inversion algorithm is applied to solve the real inverse problem and reconstruct the measured data successfully. The computational results show that the nonlinear advection-dispersion equation discussed in this paper can be utilized by hydrogeologists to research solute transport behaviors with nonlinear adsorption in porous medium.

  8. Preface for the Special Column of the INRET 2006

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ I would like to take this opportunity to thank the editorial board of Journal of Natural Gas Chemistry for allowing me to write a preface for this special column. The articles appearing in this section are specially selected from the First International Conference on Natural Resources Engineering and Technology 2006 (INRET 2006). In line with the theme of JNGC, the selected articles are focused on natural gas or low hydrocarbon conversions to important chemicals, fuels and materials.The conference was held on July 24-25, 2006 in Marriott Putrajaya, Malaysia. It was organized by the Chemical and Biotechnology (ChemBio) Focus Group, under the Research Management Centre,Universiti Teknologi Malaysia.

  9. Signal analysis of NEMS sensors at the output of a chromatography column

    Energy Technology Data Exchange (ETDEWEB)

    Bertholon, François; Harant, Olivier; Bourlon, Bertrand; Gerfault, Laurent; Grangeat, Pierre [Université Grenoble Alpes, F-38000 Grenoble (France); Jutten, Christian [Université Grenoble Alpes, F-38000 Grenoble, France and Grenoble Image Parole Signal Automatique lab, GIPSA lab UMR 5216 CNRS, 11 Rue des Mathématiques, 38400 Saint-Martin-d' Hères (France)

    2015-01-13

    This article introduces a joined Bayesian estimation of gas samples issued from a gas chromatography column (GC) coupled with a NEMS sensor based on Giddings Eyring microscopic molecular stochastic model. The posterior distribution is sampled using a Monte Carlo Markov Chain and Gibbs sampling. Parameters are estimated using the posterior mean. This estimation scheme is finally applied on simulated and real datasets using this molecular stochastic forward model.

  10. Signal analysis of NEMS sensors at the output of a chromatography column

    Science.gov (United States)

    Bertholon, François; Harant, Olivier; Jutten, Christian; Bourlon, Bertrand; Gerfault, Laurent; Grangeat, Pierre

    2015-01-01

    This article introduces a joined Bayesian estimation of gas samples issued from a gas chromatography column (GC) coupled with a NEMS sensor based on Giddings Eyring microscopic molecular stochastic model. The posterior distribution is sampled using a Monte Carlo Markov Chain and Gibbs sampling. Parameters are estimated using the posterior mean. This estimation scheme is finally applied on simulated and real datasets using this molecular stochastic forward model.

  11. Analyzing insulin samples by size-exclusion chromatography: a column degradation study.

    Science.gov (United States)

    Teska, Brandon M; Kumar, Amit; Carpenter, John F; Wempe, Michael F

    2015-04-01

    Investigating insulin analogs and probing their intrinsic stability at physiological temperature, we observed significant degradation in the size-exclusion chromatography (SEC) signal over a moderate number of insulin sample injections, which generated concerns about the quality of the separations. Therefore, our research goal was to identify the cause(s) for the observed signal degradation and attempt to mitigate the degradation in order to extend SEC column lifespan. In these studies, we used multiangle light scattering, nuclear magnetic resonance, and gas chromatography-mass spectrometry methods to evaluate column degradation. The results from these studies illustrate: (1) that zinc ions introduced by the insulin product produced the observed column performance issues; and (2) that including ethylenediaminetetraacetic acid, a zinc chelator, in the mobile phase helped to maintain column performance.

  12. Development and design of a multi-column experimental setup for Kr/Xe separation

    Energy Technology Data Exchange (ETDEWEB)

    Garn, Troy G. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Greenhalgh, Mitchell [Idaho National Lab. (INL), Idaho Falls, ID (United States); Watson, Tony [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-12-01

    As a precursor to FY-15 Kr/Xe separation testing, design modifications to an existing experimental setup are warranted. The modifications would allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents prepared using an INL patented process. A new cooling apparatus capable of achieving test temperatures to -40° C and able to house a newly designed Xe column was acquired. Modifications to the existing setup are being installed to allow for multi-column testing and gas constituent analyses using evacuated sample bombs. The new modifications will allow for independent temperature control for each column enabling a plethora of test conditions to be implemented. Sample analyses will be used to evaluate the Xe/Kr selectivity of the AgZ-PAN sorbent and determine the Kr purity of the effluent stream following Kr capture using the HZ-PAN sorbent.

  13. Investigations on the transition between column and micropinch mode of plasma focus operation

    Science.gov (United States)

    Lebert, R.; Engel, A.; Neff, W.

    1995-12-01

    X-ray emission from pinch plasma devices with pinch currents ranging from 200 to 400 kA operated with pure high-Z gases are investigated with temporal spatial and spectral resolution. If operated using elements Zneon) K-shell emission is observed from column-like volumes several 100 μm in diameter and several mm in length (bulk or column mode). For Z≳18 (e.g., krypton or xenon) emission with hν≳1 keV is only observed from micropinches. For argon (Z=18) both modes of operation can be observed. The occurrence of a specific mode depends on the initial gas pressure. In this paper the transition regime between column and micropinches is investigated with particular regard to argon. A criterion is proposed to decide whether column mode or micropinch mode is expected.

  14. Laboratory evaporation experiments in undisturbed peat columns for determining peat soil hydraulic properties

    Science.gov (United States)

    Dettmann, U.; Frahm, E.; Bechtold, M.

    2013-12-01

    Knowledge about hydraulic properties of organic soils is crucial for the interpretation of the hydrological situation in peatlands. This in turn is the basis for designing optimal rewetting strategies, for assessing the current and future climatic water balance and for quantifying greenhouse gas emissions of CO2, CH4 and N2O, which are strongly controlled by the depth of the peat water table. In contrast to mineral soils, the hydraulic properties of organic soils differ in several aspects. Due to the high amount of organic components, strong heterogeneity, and shrinkage and swelling of peat, accompanied by changing soil volume and bulk density, the applicability of standard hydraulic functions developed for mineral soils for describing peat soil moisture dynamics is often questioned. Hence, the objective of this study was to investigate the applicability of the commonly applied van Genuchten-Mualem (VGM) parameterization and to evaluate model errors for various peat types. Laboratory column experiments with undisturbed peat soils (diameter: 30 cm, height: 20 cm) from 5 different peatlands in Germany were conducted. In numerical simulations using HYDRUS-1D the experimental data were used for an inverse estimation of the soil hydraulic parameters. Using the VGM parameterization, the model errors between observed and measured pressure heads were quantified with a root mean square error (RMSE) of 20 - 65 cm. The RMSE increased for soils with higher organic carbon content and higher porosity. Optimizing the VGM 'tortuosity' parameter (τ) instead of fixing it to its default of 0.5 strongly reduced the RMSE, especially for the soils that showed high pressure head gradients during the experiment. Due to the fact, that very negative pressure heads in peatlands occur rarely, we reduced the range of pressured heads in the inversion to a 'field-relevant' range from 0 to -200 cm which strongly reduced the RMSE to 6 - 12 cm and makes the VGM parameterization applicable for all

  15. Validating the Goldstein-Wehner Law for the Stratified Positive Column of DC Discharge in an Undergraduate Laboratory

    Science.gov (United States)

    Lisovskiy, V. A.; Koval, V. A.; Artushenko, E. P.; Yegorenkov, V. D.

    2012-01-01

    In this paper we suggest a simple technique for validating the Goldstein-Wehner law for a stratified positive column of dc glow discharge while studying the properties of gas discharges in an undergraduate laboratory. To accomplish this a simple device with a pre-vacuum mechanical pump, dc source and gas pressure gauge is required. Experiments may…

  16. Effect of liquid viscosity on hydrodynamic behavior in inverse three-phase turbulent bed%液体黏度对气液固逆流三相湍动床动力学行为的影响

    Institute of Scientific and Technical Information of China (English)

    曹长青; 刘明言; 王一平; 秦秀云; 胡宗定

    2005-01-01

    Local phase holdups in an inverse three-phase turbulent bed of 150 mm i.d. auu 4350 mm height were measured simultaneously by micro-electrical conductivity probe technique in this study. Theexperiments were carried out with polyethylene particles (dp=4.01 mm, ps=926 kg·m-3), air, and water [0.05% (mass) SCMC, 0.20% (mass) SCMC] as solid phase, gas phase and liquid phase respectively. 540 sets of experimental data of local phase holdups in radial direction were obtained under Ug=Ug3. It was found that the distribution of local solid holdup showed a maximum peak at r/R=(0.75-0.90). The range of maximum peaks was larger than that of conventional fluidized beds. The distribution of local gas holdup in radial direction showed a maximum value at the column center and a minimum value near the wall. Moreover, the non-homogeneous distribution of local gas holdup in radial directions was more evident than that of conventional fluidized beds. The different operation regimes as well as the corresponding three specific gas velocities (Ug1, Ug2 and Ug3) were obtained on the basis of the axial distribution characteristics of cross-sectional average solid holdups. The effect of the operating conditions (liquid viscosity, initial volume fraction of solids Hs0/H0, initial liquid height Hl0) on the specific gas velocities was presented.

  17. Carbon monoxide total column retrievals from TROPOMI shortwave infrared measurements

    Science.gov (United States)

    Landgraf, Jochen; aan de Brugh, Joost; Scheepmaker, Remco; Borsdorff, Tobias; Hu, Haili; Houweling, Sander; Butz, Andre; Aben, Ilse; Hasekamp, Otto

    2016-10-01

    The Tropospheric Monitoring Instrument (TROPOMI) spectrometer is the single payload of the Copernicus Sentinel 5 Precursor (S5P) mission. It measures Earth radiance spectra in the shortwave infrared spectral range around 2.3 µm with a dedicated instrument module. These measurements provide carbon monoxide (CO) total column densities over land, which for clear sky conditions are highly sensitive to the tropospheric boundary layer. For cloudy atmospheres over land and ocean, the column sensitivity changes according to the light path through the atmosphere. In this study, we present the physics-based operational S5P algorithm to infer atmospheric CO columns satisfying the envisaged accuracy ( information on atmospheric scattering. For efficient processing, we deploy a linearized two-stream radiative transfer model as forward model and a profile scaling approach to adjust the CO abundance in the inversion. Based on generic measurement ensembles, including clear sky and cloudy observations, we estimated the CO retrieval precision to be ≤ 11 % for surface albedo ≥ 0.03 and solar zenith angle ≤ 70°. CO biases of ≤ 3 % are introduced by inaccuracies in the methane a priori knowledge. For strongly enhanced CO concentrations in the tropospheric boundary layer and for cloudy conditions, CO errors in the order of 8 % can be introduced by the retrieval of cloud parameters of our algorithm. Moreover, we estimated the effect of a distorted spectral instrument response due to the inhomogeneous illumination of the instrument entrance slit in the flight direction to be < 2 % with pseudo-random characteristics when averaging over space and time. Finally, the CO data exploitation is demonstrated for a TROPOMI orbit of simulated shortwave infrared measurements. Overall, the study demonstrates that for an instrument that performs in compliance with the pre-flight specifications, the CO product will meet the required product performance well.

  18. Isotopic fractionation of fentanyl and its deuterated analogues by capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan)

    1997-12-01

    Isotopic fractionation of fentanyl (FT) and its deuterated analogues by gas chromatography using capillary columns (CBP1 and CBP5) has been investigated. Seven kinds of analogues were labeled with 5 to 19 deuterium atoms at the anilino, propionyl and/or phenylethyl group of FT. The retention times of deuterated FT in CBP1 and CBP5 columns are inversely proportional to the number of labeled deuterium atoms in the molecule. The difference in free enegy changes ({Delta}{Delta}G) had a linear relationship with the number of labeled deuterium atoms, except for labeling at anilino and phenylethyl group. The contribution of a deuterium atom to the {Delta}{Delta}G value was estimated to be 1.13 cal/mol in CBP1 and 1.40 cal/mol in CBP5, respectively. While, its contribution in the propiony group was 2.84 cal/mol in CBP1 and 2.48 cal/mol in CBP5, respectively. An important factor in separation by GC may differences in interactions between the stationary phase of the column with the three dimensional protrusive moiety in the molecule. (author)

  19. Parameter estimation and inverse problems

    CERN Document Server

    Aster, Richard C; Thurber, Clifford H

    2005-01-01

    Parameter Estimation and Inverse Problems primarily serves as a textbook for advanced undergraduate and introductory graduate courses. Class notes have been developed and reside on the World Wide Web for faciliting use and feedback by teaching colleagues. The authors'' treatment promotes an understanding of fundamental and practical issus associated with parameter fitting and inverse problems including basic theory of inverse problems, statistical issues, computational issues, and an understanding of how to analyze the success and limitations of solutions to these probles. The text is also a practical resource for general students and professional researchers, where techniques and concepts can be readily picked up on a chapter-by-chapter basis.Parameter Estimation and Inverse Problems is structured around a course at New Mexico Tech and is designed to be accessible to typical graduate students in the physical sciences who may not have an extensive mathematical background. It is accompanied by a Web site that...

  20. Testing earthquake source inversion methodologies

    KAUST Repository

    Page, Morgan T.

    2011-01-01

    Source Inversion Validation Workshop; Palm Springs, California, 11-12 September 2010; Nowadays earthquake source inversions are routinely performed after large earthquakes and represent a key connection between recorded seismic and geodetic data and the complex rupture process at depth. The resulting earthquake source models quantify the spatiotemporal evolution of ruptures. They are also used to provide a rapid assessment of the severity of an earthquake and to estimate losses. However, because of uncertainties in the data, assumed fault geometry and velocity structure, and chosen rupture parameterization, it is not clear which features of these source models are robust. Improved understanding of the uncertainty and reliability of earthquake source inversions will allow the scientific community to use the robust features of kinematic inversions to more thoroughly investigate the complexity of the rupture process and to better constrain other earthquakerelated computations, such as ground motion simulations and static stress change calculations.