WorldWideScience

Sample records for colorectal stent placement

  1. Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hyung; Shin, Ji Hoon; Kim, Jin Hyoung; Lim, Jin-Oh; Kim, Kyung Rae [Asan Medical Center, Radiology and Research Institute of Radiology, Seoul (Korea); Song, Ho-Young [Asan Medical Center - Radiology, Songpa-gu, Seoul (Korea); Park, In Kook [Dongguk University, Life Science, Seoul (Korea); Choi, Eugene K. [Weill Medical College of Cornell University, New York, NY (United States)

    2008-11-15

    The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to presence of nearly complete small bowel obstruction. The average length of stricture was 6.15 cm (range, 3 cm to 20 cm) in patients with the colorectal stricture. There were no procedure-related complications. In conclusion, the multifunctional coil catheter seems to be useful in colorectal stent placement. (orig.)

  2. [Two Cases of Obstructive Colorectal Cancer Effectively Treated with Colonic Stent Placement].

    Science.gov (United States)

    Masuda, Taiki; Kobayashi, Kenta; Kakimoto, Masaki; Koshiishi, Haruya; Yoshimura, Tetsunori

    2016-11-01

    We report 2 cases of obstructive colorectal cancer that were successfully treated with a self-expanding metallic stent (SEMS). They were both diagnosed with obstructive colorectal cancer. Colonoscopy was performed to make a definitive and qualitative diagnosis and to relieve the stenosis using a SEMS. The SEMSs were inserted without complications. A few days later, the patients underwent laparoscope-assisted sigmoidectomy with lymph node resection. Despite the colon obstruction, a primary anastomosis was performed. They were both discharged without complications. Obstructive colorectal cancer is an oncological emergency commonly observed in our daily clinical practice. Conventional treatments such as stoma creation or insertion of a trans-analdrainage tube have been performed. However, these treatments significantly reduce the patient's QOL. On the other hand, colonic stent placement plays a satisfactory role in improvement of the patient's QOL by paying scrupulous attention to retaining the colonic stent.

  3. Delayed colonic perforation following stent placement for colorectal obstruction: a description of two cases with stent palliation.

    Directory of Open Access Journals (Sweden)

    Jalal Vahedian Ardakani

    2013-10-01

    Full Text Available Bowel stent insertion has a variety of complications one major of which is colonic perforation. The purpose of this article is to reveal two cases with delayed colonic perforation after stent placement to relieve bowel obstruction caused by rectal cancer. The first patient was a 55 year-old man who was a candidate for stent placement to avoid palliative surgery and relieve his bowel obstruction. Although the procedure resulted in complete relief of patient symptoms, but he returned with signs of peritonitis 10 days after the stent placement. A perforation was found at rectosigmoid junction on laparotomy. The second patient was a 60 year-old man who underwent a successful stent placement and returned 3 months later with a complaint of abdominal pain that showed up to be due to a rectal perforation on investigations. In conclusion, bowel perforation following stent placement can be a major complication, so close follow-up is necessary to detect it as soon as possible and prevent it from becoming an irreparable complication.

  4. Trajectory surgical guide stent for implant placement.

    Science.gov (United States)

    Adrian, E D; Ivanhoe, J R; Krantz, W A

    1992-05-01

    This article describes a new implant placement surgical guide that gives both implant location and trajectory to the surgeon. Radiopaque markers are placed on diagnostic dentures and a lateral cephalometric radiograph is made that shows the osseous anatomy at the symphysis and the anterior tooth location. The ideal implant location and trajectory data are transferred to a surgical stent that programs the angle and location of the fixtures at time of surgery. The stent has the additional benefit of acting as an occlusion rim, a mouth prop, and tongue retractor. Use of this stent has resulted in consistently programming the placement of implant fixtures that are prosthodontically ideal.

  5. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  6. A Dual Expandable Stent for Treatment of Malignant Colorectal Obstruction: Long-Term Follow-Up Results

    Energy Technology Data Exchange (ETDEWEB)

    Son, Won Young; Kang, Hee; Jung, Gyoo Sik [Dept. of Radiology, Kosin University College of Medicine, Gospel Hospital, Busan (Korea, Republic of)

    2012-11-15

    To analyze the long-term results and to evaluate the efficacy of a dual expandable stent for the treatment of malignant colorectal strictures. Under the fluoroscopic guidance, stents were placed in 60 patients with malignant colorectal strictures. A dual stent consists of two stents, the outer stent was placed into the stricture which was followed by coaxial placement of the inner bare stent. Technical and clinical success rates, complications, patient survival and stent patency during the follow-up period were evaluated in this study. Stent placement was technically successful in 57 of 60 patients (95%). Of them, obstructive symptoms resolved within two days in 12/12 (100%) patients in the preoperative group and in 36/45 (80%) patients in the palliative group. Complications associated with this procedure were perforation (n = 5), migration (n = 3), and tumor overgrowth (n = 2). Each of the six patients in the preoperative group underwent conventional laparotomy and laparoscopic surgery, respectively. The mean interval between stent insertion and surgery was nine days. In the palliative group, the median survival was 159 days (mean; 235) and the median patency of stent was 116 days (mean; 185). 1-month, 3-month, 6-month, 12-month and 24-month stent patency were 75%, 60%, 27%, 13% and 7%, respectively. Insertion of a dual expandable nitinol stent into malignant colorectal obstruction is a safe and effective procedure for the palliative treatment of malignant colorectal obstruction. This procedure is also effective for preoperative decompression.

  7. Self-Expandable Metal Stents for Colorectal Cancer: From Guidelines to Clinical Practice

    Directory of Open Access Journals (Sweden)

    Maria Pia Costa Santos

    2016-11-01

    Conclusions: In this study, stent placement was an effective procedure in obstructive colorectal cancer. It was mainly used as a bridge to elective surgery. However, a significant rate of silent perforation was observed, which may compromise the oncological outcome of these potentially curable patients. Prospective real life studies are warranted for a better definition of actual recommendations.

  8. Ultraflex precision colonic stent placement as a bridge to surgery in patients with malignant colon obstruction

    DEFF Research Database (Denmark)

    Fregonese, D.; Naspetti, R.; Ferrer, S.;

    2008-01-01

    Background: Emergency surgery for malignant colon obstruction entails relatively high morbidity and mortality rates and typically necessitates a 2-step resection. These problems might be potentially mitigated by placement of a self-expanding metal stent (SEMS) as a bridge to surgery. A nitinol...... colorectal SEMS may offer several advantages, but available evidence on the utility of this SEMS type remains highly limited. Objective: Our purpose was to evaluate the effectiveness and safety as a bridge to surgery of a nitinol SEMS designed for colorectal use. Design: Prospective and retrospective...... multicenter clinical study. Setting: Sixteen European study centers. Patients: Thirty-six patients with malignant colonic obstruction. Interventions: Nitinol colorectal SEMS placement. Main Outcome Measures: Technical success in accurate SEMS placement with coverage of the entire stricture length, clinical...

  9. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive......, probably caused by ischemic conditions developed before stent-decompression of the colon was revealed during the operation. The patient died in the postoperative course. We discuss the observation of patients treated with self-expanding metal stents based on the selection-strategy used to allocate patients...

  10. Metallic stent placement for the management of acute colorectal obstruction caused by colorectal carcinomas: its effect on scheduled surgery%急性结肠梗阻支架置入对结直肠癌择期手术的作用

    Institute of Scientific and Technical Information of China (English)

    曹燕; 刘冰妍; 茅爱武; 殷响; 高中度

    2011-01-01

    Objective To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent ( SEMS ) placement in the treatment of patients with acute malignant colorectal obstruction due to colorectal carcinomas. Methods During the period from April 2001 to October 2007 , a total of 52 patients with acute malignant colorectal obstruction were treated with stent placement by using a new designed SEMS, which was employed as a preoperative transit means. All the patients were followed up and the relevant data, including technical success rate, clinical efficacy, complications and overall survival rate, were documented. The results were analyzed. Results Stent placement was successfully carried out in all patients except for two patients who showed complete colorectal obstruction. No procedure-related complications occurred. Technical success rate was 96% ( 50/52 ). Two days after the treatment,, the relief rate of colorectal obstruction was 98% ( 49/50 ). Postoperative complications included stent migration ( n =4 ), anal pain ( n = 2 ) and stool impaction ( n = 1 ). The stool impaction seen in one patient was successfully removed away with endoscopic manipulation two days after stent placement. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS placement within a mean interval of ( 8 ± 2 ) days ( ranged 4 - 11 days ) after stent placement. Mean follow-up time was ( 36 ± 12 ) months with a range of ( 3 - 70 ) months. All patients remained alive at the time of this report. Conclusion The newly designed SEMS placement used as a preoperative transit means is a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction due to colorectal carcinomas.It can reliably ensure most of patients with colorectal carcinomas to successfully accomplish an elective surgery. ( J Intervent Radiol, 2011, 20 : 799-802 )%目的 探讨自膨胀金

  11. Development of VVF following double J stent placement.

    Science.gov (United States)

    Priyadarshi, Vinod; Sinhamahapatra, RajKumar; Kundu, Anup Kumar; Pal, DilipKumar

    2014-05-09

    Double J stent (DJ stent) is commonly used in various urological conditions. Theoretically stent-induced tissue erosion can be a possibility, but fistula formation is rarely reported. The present case was a case of genitourinary tuberculosis diagnosed 4 years ago and had received complete treatment. Two months ago she presented with recurrent urinary tract infection and diagnosed to have vesicoureteric reflux with secondary obstruction for which DJ stent was placed, after 15 days of which the patient reported leakage of urine per vagina. She was diagnosed to have vesicovaginal fistula (VVF) with in situ stent eroding through the bladder wall. Stent was removed and fistula was corrected surgically. This is the first reported case of stent-induced VVF, a rare complication of ureteral stent placement.

  12. Mathematical model of carotid artery for stent placement

    Science.gov (United States)

    Rahman, Tengku Husna Tengku Abdul; Din, Ummul Khair Salma; Ahmad, Rokiah @ Rozita

    2016-11-01

    The carotid artery stenting is one of the methods used to reduce the effect of artherosclerosis which caused by the thickening of the artery wall. In most of the studies, the measure of wall elasticity, shear stress and the blood pressure through the blood flow were considered. The aim of this study is to determine the position to place the stent inside the carotid artery. A mathematical model is reconstructed to determine the suitable location of the stent in the carotid artery. Throughout the study, differences in fluid flow between a normal carotid artery wall and stenosed carotid artery wall are investigated. Since the existence of the stenosis provides a resistance in the flow, it is important to identify the right position to place the stent. The stent will be placed in the position where stenosis exists to ease the blood to flow normally. Later after the stent placement, the blood flow normally through the blood vessel.

  13. Frequency and consequences of early in-stent lesions after carotid artery stent placement.

    NARCIS (Netherlands)

    Jongen, L.M.; Hendrikse, J.; Waaijer, A.; Worp, H.B. van der; Leijdekkers, V.J.; Lo, R.T.; Mali, W.P.Th.; Prokop, M.

    2009-01-01

    PURPOSE: To examine the prevalence of in-stent lesions 1 month after carotid artery stent placement with multidetector computed tomography (CT) angiography and to evaluate their possible causes and their consequences during 1-year follow-up. MATERIALS AND METHODS: Sixty-nine patients with symptomati

  14. Complications of stent placement for benign stricture of gastrointestinal tract

    Institute of Scientific and Technical Information of China (English)

    Ying-Sheng Cheng; Ming-Hua Li; Wei-Xiong Chen; Ni-Wei Chen; Qi-Xin Zhuang; Ke-Zhong Shang

    2004-01-01

    AIM: To observe the frequent complications of stent placement for stricture of the gastrointestinal tract and to find proper treatment.METHODS: A total number of 140 stents were inserted in 138 patients with benign stricture of the gastrointestinal tract. The procedure was completed under fluoroscopy in all of the patients.RESULTS: Stents were successfully placed in all the 138 patients. Pains occurred in 23 patients (16.7%), slight or dull pains were found in 21 patients and severe chest pain in 2 respectively.For the former type of pain, the patients received only analgesia or even no treatment, while peridural anesthesics was conducted for the latter condition. Reflux occurred in 16 of these patients (11.6%) after stent placement. It was managed by common antireflux procedures. Gastrointestinal bleeding occurred in 13 patients (9.4%), and was treated by hemostat. Restenosis of the gastrointestinal tract occurred in 8 patients (5.8%), and was apparently associated with hyperplasia of granulation tissue. In 2 patients, the second stent was placed under X-ray guidance. The granulation tissue was removed by cauterization through hot-node therapy under gastroscope guidance in 3 patients, and surgical reconstruction was performed in another 3 patients. Stent migration occurredin 5 patients (3.6%), and were extracted with the aid of a gastroscope. Food-bolus obstruction was encountered in 2 patients (1.4%) and was treated by endoscope removal. No perforation occurred in all patients.CONCLUSION: Frequent complications after stent placement for benign stricture of the gastrointestinal tract include pain,reflux, bleeding, restenosis, stent migration and food-bolus obstruction. They can be treated by drugs, the second stent placement or gastroscopic procedures according to the specific conditions.

  15. Long-term effect of stent placement in 115 patients with Budd-Chiari syndrome

    Institute of Scientific and Technical Information of China (English)

    Chun-Qing Zhang; Li-Na Fu; Lin Xu; Guo-Quan Zhang; Tao Jia; Ji-Yong Liu; Cheng-Yong Qin; Ju-Ren Zhu

    2003-01-01

    AIM: To report the long-term effect of stent placement in 115 patients with Budd-Chiari syndrome (BCS).METHODS: One hundred and fifteen patients with BCS were treated by percutaneous stent placement. One hundred and two patients had IVC stent placement, 30 patients had HV stent placement, 17 of them underwent both IVC stent and HV stent. All the procedures were performed with guidance of ultrasound.RESULTS: The successful rates in placing IVC stent and HV stent were 94 % (96/102) and 87 % (26/30), respectively.Ninety-seven patients with 112 stents (90 IVC stents, 22 HV stents) were followed up. 96.7 %(87/90) IVC stents and 90.9 %(20/22) HV stents remained patent during follow up periods (mean 49 months, 45 months, respectively). Five of 112 stents in the 97 patients developed occlusion. Absence of anticoagulants after the procedure and types of obstruction (segmental and occlusive) before the procedure were related to a higher incidence of stent occlusion.CONCLUSION: Patients with BCS caused by short length obstruction can be treated by IVC stent placement, HV stent placement or both IVC and HV stent placement depending on the sites of obstruction. The long-term effect is satisfactory.Anticoagulants are strongly recommended after the procedure especially for BCS patients caused by segmental occlusion.

  16. Stent placement for esophageal strictures : an update

    NARCIS (Netherlands)

    Hirdes, Meike Madeleine Catharine; Vleggaar, Frank Paul; Siersema, Peter Derk

    2011-01-01

    The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief

  17. Usefulness of flexible covered stent in malignant colorectal obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jee Hee; Kang, Sung Gwon; Kim, Hyung Jin; Noh, Hong Gi; Woo, Jae Hong; Suh, Chang Hae [Inha Univ. Hospital, Inchon (Korea, Republic of)

    1998-07-01

    To evaluate the usefulness of flexible covered stent in the treatment of acute colorectal obstruction secondary to colorectal carcinoma. Materials and Methods : Flexible covered stents were placed in 11 patients with clinical and radiologic signs of acute colonic obstruction secondary to colorectal carcinoma. The purposes of stent insertion were pre-operative bowel preparation in seven patients and palliative treatment in four. A fistula was present in two;in one this was between the proximal jejunum and colon, and the other was rectovaginal. The usefulness of stent insertion for the purpose of preoperative bowel preparation was evaluated according to the feasibility and status of bowel preparation, as decided by the operator. Palliative treatment for the relief of symptoms of acute bowel obstruction was evaluated according to the number and amount of defecation,bowel dilatation in simple abdomen radiography, and the presence of complications. Results : Bowel preparation for the purpose of preoperative bowel cleansing was easy in seven patients;the fecal materials remaining in the colon presented no problems during surgery. In one of four patients palliative treatment involved a colostomy;this was due to recurrent stent obstruction by fecal materials after three months, and in two other patients there was stent obstruction after two and five months, respectively. The stent in one of four patients who underwent palliative treatment was removed because of stent migration three days after insertion;the stents in two patients with fistulas covered the fistulas successfully. Complications after stent insertion were anal pain in three patients, anal bleeding in three and stent migration in one. Conclusion : The flexible covered stent was an effective device for the relief of acute colonic obstruction secondary to malignant rectosigmoid neoplasia. It allowed for single-stage operation and covered the fistula. We believe however that for further evaluation of the

  18. Endoscopic pancreatic duct stent placement for inflammatory pancreatic diseases

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The role of endoscopic therapy in the management of pancreatic diseases is continuously evolving; at present most pathological conditions of the pancreas are successfully treated by endoscopic retrograde cholangiopancreatography (ERCP) or endoscopic ultrasound (EUS),or both. Endoscopic placement of stents has played and still plays a major role in the treatment of chronic pancreatitis, pseudocysts, pancreas divisum, main pancreatic duct injuries, pancreatic fistulae, complications of acute pancreatitis, recurrent idiopathic pancreatitis,and in the prevention of post-ERCP pancreatitis. These stents are currently routinely placed to reduce intraductal hypertension, bypass obstructing stones, restore lumen patency in cases with dominant, symptomatic strictures,seal main pancreatic duct disruption, drain pseudocysts or fluid collections, treat symptomatic major or minor papilla sphincter stenosis, and prevent procedure-induced acute pancreatitis. The present review aims at updating and discussing techniques, indications, and results of endoscopic pancreatic duct stent placement in acute and chronic inflammatory diseases of the pancreas.

  19. Use of an introducer sheath for colonic stent placement

    Energy Technology Data Exchange (ETDEWEB)

    De Gregorio, Miguel A.; Mainar, Antonio; Alfonso, Eduardo; Gimeno, Maria Jose [Department of Interventional Radiology, University Hospital of Zaragoza, C/ San Juan Bosco, 15, 50009 Zaragoza (Spain); Tejero, Eloy [Department of Surgery, University Hospital of Zaragoza, C/ San Juan Bosco, 15, 50009 Zaragoza (Spain); Herrera, Marcos [Department of Radiology, Hennepin County Medical Center, Minneapolis, MN 55408 (United States)

    2002-09-01

    We describe a technical modification of Wallstent implantation for the treatment of malignant rectosigmoid and descending colonic obstructions. The modification is the routine placement of an introducer sheath via the rectum before stent implantation in order to straighten the rectosigmoid region. This device facilitates catheter and guide wire manipulations and obtaining specimen biopsies for histopathological studies. The introducer sheath has been used without complications in 21 consecutive patients. (orig.)

  20. Shortening of Wallstent RP during carotid artery stenting requires appropriate stent placement.

    Science.gov (United States)

    Aikawa, Hiroshi; Nagata, Shun-ichi; Onizuka, Masanari; Tsutsumi, Masanori; Iko, Minoru; Kodama, Tomonobu; Nii, Kouhei; Matsubara, Shuko; Etou, Hosei; Go, Yoshinori; Kazekawa, Kiyoshi

    2008-06-01

    Changes in the location and length of the Wallstent RP during carotid artery stenting (CAS) were evaluated using intraoperative videos of 28 patients with carotid artery stenosis who underwent CAS with a 10/20 mm Wallstent RP to determine the appropriate stent placement. The stent was deployed after its midpoint was positioned over a virtual center line, the perpendicular line which crossed the most stenotic point of the lesion on the road mapping image. The length of the stenotic lesion, the changes in the locations of the distal and proximal ends of the stent, and the changes in stent length were examined. The distal end of the stent moved a maximum of 6.1 mm toward the proximal side to a point 19.9 mm from the virtual center line. The proximal end moved a maximum of 11.3 mm toward the distal side to a point 14.7 mm from the virtual center line. The stent length ranged from 37.7 to 44.5 mm (mean 41.2 mm). The 10/20 mm Wallstent RP placed by our technique covers the entire lesion with no less than 5.7 mm of margin over the segment distal to the lesion in patients with stenotic segments shorter than 29.4 mm.

  1. Partial stent-in-stent placement of biliary metallic stents using a short double-balloon enteroscopy

    Institute of Scientific and Technical Information of China (English)

    Koichiro Tsutsumi; Hironari Kato; Takeshi Tomoda; Kazuyuki Matsumoto; Ichiro Sakakihara; Naoki Yamamoto; Yasuhiro Noma

    2012-01-01

    Endoscopic intervention is less invasive than percutaneous or surgical approaches and should be considered the primary drainage procedure in most cases with obstructive jaundice.Recently,therapeutic endoscopic retrograde cholangiopancreatography (ERCP) using double-balloon enteroscopy (DBE) has been shown to be feasible and effective,even in patients with surgically altered anatomies.On the other hand,endoscopic partial stent-in-stent (PSIS) placement of selfexpandable metallic stents (SEMSs) for malignant hilar biliary obstruction in conventional ERCP has also been shown to be feasible,safe and effective.We performed PSIS placement of SEMSs for malignant hilar biliary obstruction due to liver metastasis using a short DBE in a patient with Roux-en-Y anastomosis and achieved technical and clinical success.This procedure can result in quick relief from obstructive jaundice in a single session and with short-term hospitalization,even in patients with surgically altered anatomies.

  2. Clinical application of self-expanding metallic stent in the management of acute left-sided colorectal malignant obstruction

    Institute of Scientific and Technical Information of China (English)

    You-Ben Fan; Ying-Sheng Cheng; Ni-Wei Chen; Hui-Min Xu; Zhe Yang; Yue Wang; Yu-Yao Huang; Qi Zheng

    2006-01-01

    AIM: To summarize our experience with the application of self-expanding metallic stent (SEMS) in the management of acute left-sided colorectal malignant obstruction.METHODS: A retrospective chart review of all patients undergoing placement of SEMS between April 2000 and January 2004 was performed.RESULTS: Insertion of SEMS was attempted in 26patients under fluoroscopic guidance with occasional endoscopic assistance. The sites of lesions were located in splenic flexure of two patients, left colon of seven patients, sigmoid colon of eight patients and rectum of nine patients. The intended uses of SEMS were for palliation in 7 patients and as a bridge to elective surgery in 19 patients. In the latter group, placement of SEMS allowed for preoperative systemic and bowel preparation and the following one-stage anastomosis. Successful stent placement was achieved in 22 (85%) of the 26patients. The clinical bowel obstruction resolved 24 hours after successful stent placement in 21 (95%) patients.Three SEMS-related minor complications occurred, two stents migrated and one caused anal pain.CONCLUSION: SEMS represents an effective and safe tool in the management of acute malignant colorectal obstruction. As a bridge to surgery, SEMS can provide time for systematic support and bowel preparation and obviate the need for fecal diversion or on-table lavage.As a palliative measure, SEMS can eliminate the need for emergent colostomy.

  3. Very late stent thrombosis following the placement of a crossing Y-stent with dual closed-cell stents for the coiling of a wide-necked aneurysm.

    Science.gov (United States)

    Lee, Chang-Young; Kim, Chang-Hyun

    2015-02-01

    The crossing Y-stent technique is a viable option for coiling of wide-necked bifurcation aneurysms. However, little is known about the long-term impact of this technique. Very late (>1 year) stent thrombosis following the placement of a crossing Y-stent with dual closed-cell stents for the coiling of a wide-necked basilar tip aneurysm, which has not been reported to date, is described.

  4. Surgical gastrojejunostomy or endoscopic stent placement for the palliation of malignant gastric outlet obstruction (SUSTENT study): a multicenter randomized trial

    NARCIS (Netherlands)

    S.M. Jeurnink; E.W. Steyerberg; J.E. van Hooft; C.H.J. van Eijck; M.P. Schwartz; F.P. Vleggaar; E.J. Kuipers; P.D. Siersema

    2010-01-01

    BACKGROUND: Both gastrojejunostomy (GJJ) and stent placement are commonly used palliative treatments of obstructive symptoms caused by malignant gastric outlet obstruction (GOO). OBJECTIVE: Compare GJJ and stent placement. DESIGN: Multicenter, randomized trial. SETTING: Twenty-one centers in The Net

  5. Endovascular stent-graft placement for treatment of type B dissections

    Institute of Scientific and Technical Information of China (English)

    俞飞成

    2006-01-01

    Objective To evaluate the safety and effectiveness of endovascular stent-graft placement for treatment of type B dissection. Methods From April 2002 to December 2005,180 patients with type B dissection underwent endovascular stent-graft placement. There were 158 men and 22 women with mean age of 50. 4±10. 9 years. All patients were diagnosed by computed tomography(CT) or magnetic resonance imaging (MRI) scans. Stent-graft

  6. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung [Dept. of University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Yeoun Joo [Dept. of Pediatrics, Pusan National University Children' s Hospital, Yangsan (Korea, Republic of)

    2013-06-15

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  7. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ye Jin; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2012-10-15

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10-119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  8. Percutaneous transcholecystic approach for an experiment of biliary stent placement: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Medical School of Gachon, Inchon (Korea, Republic of); Song, Ho Young; Lim, Jin Oh; Ko, Gi Young; Sung, Kyu Bo; Kim, Tae Hyung; Lee, Ho Jung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-06-01

    To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2,4 and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrified, and a pathologic examination was performed. Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks. Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-period.

  9. Endovascular stent placement in the treatment of upper extremity central venous obstruction in hemodialysis patients

    Energy Technology Data Exchange (ETDEWEB)

    Aytekin, Cueneyt E-mail: cuneytaytekin@hotmail.com; Boyvat, Fatih; Yagmurdur, Mahmut Can; Moray, Goekhan; Haberal, Mehmet

    2004-01-01

    Objective: To evaluate the efficacy of stent placement for treating upper extremity central venous obstruction in chronic hemodialysis patients. Methods and Material: Between January 1999 and October 2001, we inserted metallic stents into the upper extremity central veins of 14 patients with shunt dysfunction and/or arm swelling. The indications for stent placement were stenosis or occlusion of the central vein in the upper extremity used for dialysis. Six of the individuals were diagnosed with subclavian vein stenosis, and 5 with brachiocephalic vein stenosis. Of the remaining 3 patients, 2 had subclavian vein occlusion, and 1 had left brachiocephalic vein occlusion. Results: All the stent placement procedures were technically successful, and there were no major complications. Follow-up ranged from 2 weeks to 29 months. The 1-, 3-, 6- and 12-month primary stent patency rates were 92.8, 85.7, 50 and 14.3%, respectively. Repeat interventions, including percutaneous transluminal angioplasty and additional stent placement, were required in 9 patients. The 3-, 6-, 12-month, and 2-year assisted primary stent patency rates were 100, 88.8, 55.5 and 33.3%, respectively. Conclusion: Endovascular stent placement is an effective alternative to surgery in patients with shunt dysfunction due to obstruction of an upper extremity central vein. Repeated interventions are usually required to prolong stent patency.

  10. Brachytherapy for the prevention of neointimal hyperplasia in the canine inferior vena cava after stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Isota, Masayuki; Kaminou, Toshio; Sakai, Yukimasa; Nakamura, Kenji; Yamada, Ryusaku [Osaka City Univ. (Japan). Medical School

    2002-06-01

    The aim of this study was to evaluate the efficacy of brachytherapy for preventing neointimal hyperplasia in the inferior vena cava (IVC) after stent placement. Sixteen beagles underwent Z-stent placement in the IVC and the aorta. For 8 of 16 beagles, irradiation (15 Gy) was delivered endoluminally to the stented segments of each vessel immediately after stent placement using the {sup 192}Ir. All animals were sacrificed after 6 weeks for morphometric and histopathologic examination. Morphometrically, neointimal thickness in the IVC of the radiation group was significantly decreased compared with the control group as well as that in the aorta (p<0.05). Histopathologic findings showed the neointima in the IVC of the control group contained markedly organization of thrombus and neovascularization though that in the IVC of the radiation group consisted mainly of smooth muscle cells without organization of thrombus and neovascularization. From these data intravenous irradiation may prevent clinical restenosis after stent placement. (author)

  11. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B [Division of Interventional Radiology, University of Michigan, Ann Arbor (United States)

    2011-11-15

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  12. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan [Asan Medical Center, Seoul (Korea, Republic of)

    2004-04-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications.

  13. Impact of myocardial bridge on clinical outcome after coronary stent placement.

    Science.gov (United States)

    Tsujita, Kenichi; Maehara, Akiko; Mintz, Gary S; Doi, Hiroshi; Kubo, Takashi; Castellanos, Celia; Liu, Jian; Yang, Junqing; Oviedo, Carlos; Franklin-Bond, Theresa; Sugirtharaj, Dorcas Deborah; Dangas, George D; Lansky, Alexandra J; Stone, Gregg W; Moses, Jeffrey W; Leon, Martin B; Mehran, Roxana

    2009-05-15

    Most intravascular ultrasound (IVUS)-identifiable myocardial bridges (MBs) were not appreciated angiographically, especially when they occurred adjacent to fixed proximal obstructive disease. The impact of MB stent placement on clinical outcome was determined in 317 consecutive patients with obstructive left anterior descending coronary artery lesions undergoing coronary stent placement. In these patients, IVUS identified 70 MBs, defined as a segment of coronary artery with both systolic compression and perivascular echolucent muscle. IVUS showed that the stent extended into the MB segment beyond the obstructive lesion in 24 patients (34%; MB stent group), although significant plaque was not observed within any MB segment. In the remaining 46 patients, the left anterior descending artery stent was implanted in only the obstructive lesion, avoiding the distal MB segment (non-MB stent group). Minimum stent area was significantly smaller in the MB stent group than non-MB stent group (4.8 +/- 1.1 vs 5.8 +/- 1.8 mm(2); p = 0.02). Rates of target-lesion revascularization, target-vessel revascularization, and composite end point (death/myocardial infarction/target-lesion revascularization/target-vessel revascularization, evaluated at a mean follow-up of 358 +/- 252 days) were more common in patients with versus without MB stent placement. Specifically, target-lesion revascularization rates were 24% versus 3%, respectively (log-rank p = 0.003). In-stent restenosis occurred within the stented MB segment in 3 of 5 MB stent group patients who required target-lesion revascularization (60%). In conclusion, inadvertent MB stent placement in left anterior descending artery lesions occurred commonly and may have been associated with an increased incidence of late events.

  14. Self-expandable nitinol stent placement in homocysteinemic porcine aorta

    Directory of Open Access Journals (Sweden)

    Luís Henrique Gil França

    2008-01-01

    Full Text Available PURPOSE: To compare aortic intimal thickening of normal and hyperhomocysteinemic pigs (induced with a methionine-rich diet following placement of a self-expanding nitinol stent. METHODS: Eighteen Macau pigs were used. They were older than eight weeks in age and had an average weight of 30 kg. Pigs were randomly divided into two groups. The first, Group C (control, was fed a regular diet, and the second group, Group M, was fed a methionine-rich diet for 30 days to induce hyperhomocysteinemia. The self-expandable nitinol stents were 25mm in length and 8 mm in diameter after expansion. Blood samples were collected to measure total cholesterol, triglycerides, HDL and homocysteine concentrations. All animals were subjected to angiography. Thirty days after the procedure, the animals were sacrificed, and the abdominal aorta was removed for histological and digital morphometry analysis. RESULTS: Under microscopic evaluation, the intima was significantly thicker in Group C than in Group M. When groups were compared by digital morphometric analysis, intimal thickening of the vessel wall was higher in Group C than in Group M. There was no significant change in total cholesterol, triglycerides or HDL concentrations in either group. In group C the levels of plasma homocysteine ranged from 14,40 to 16,73µmol/l; in Group M, plasma homocysteine levels ranged from 17.47 to 59.80 µmol/l after 30 days of a methionine-rich diet. CONCLUSION: Compared to normal pigs, less intimal hyperplasia was observed in the abdominal aortas of hyperhomocysteinemic pigs thirty days after the insertion of a self-expandable nitinol stent.

  15. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  16. Clinical evaluation of radiotherapy for advanced esophageal cancer after metallic stent placement

    Institute of Scientific and Technical Information of China (English)

    You-Tao Yu; Guang Yang; Yan Liu; Bao-Zhong Shen

    2004-01-01

    AIM: To evaluate the therapeutic effect of radiotherapy for esophageal cancer after expandable metallic stent placement.METHODS: Ten cases of advanced esophageal cancer were evaluated, 7 having complete obstruction and 3 with digestive-respiratory fistula. Ten nitinol stents were placed at the site of stenosis. Patients were treated with a total dose of 1 200 cGy divided into 3 fractions of 400 cGy 4-7 d after stents placement.RESULTS: All the 10 stents were placed successfully at one time. After radiotherapy for advanced esophageal cancer, the survival period of the cases ranged from 14 to 22 mo, with a mean survival of 17 mo. No re-stenosis occurred among all the 10 cases.CONCLUSION: Stent placement combined with radiotherapy for esophageal cancer is helpful to prolong patients' survival and reduce occurrence of re-stenosis.

  17. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  18. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  19. Colorectal stenting for colonic obstruction: The indications, complications, effectiveness and outcome-5-Year review

    Energy Technology Data Exchange (ETDEWEB)

    Athreya, S. [Department of Radiology, Gartnavel General Hospital, Great Western Road, Glasgow (United Kingdom)]. E-mail: harshavbs@yahoo.com; Moss, J. [Department of Radiology, Gartnavel General Hospital, Great Western Road, Glasgow (United Kingdom)]. E-mail: j.moss@clinmed.gla.ac.uk; Urquhart, G. [Department of Radiology, Southern General Hospital, Glasgow (United Kingdom); Edwards, R. [Department of Radiology, Gartnavel General Hospital, Great Western Road, Glasgow (United Kingdom); Downie, A. [Department of Radiology, Victoria Infirmary, Glasgow (United Kingdom); Poon, F.W. [Department of Radiology, Royal Infirmary, Glasgow (United Kingdom)

    2006-10-15

    Introduction: Currently self-expanding metallic stents are being used for palliation and acute decompression of colonic obstruction. The aim of this study is to review our experience of using these metallic stents over a 5-year period. Materials and methods: Case records of 102 patients who had colorectal stenting between 1998 and 2004 were reviewed retrospectively. The indications for colorectal stenting, efficacy of the procedure in relieving the obstruction, complications and clinical outcome were analysed. Results: Ninety-nine patients had malignant disease and in three patients a benign cause of obstruction was demonstrated. All procedures were performed during normal working hours. Stenting was technically successful in 87 patients (85%). A single stent was placed in 80 patients. Seven patients required two stents. Of the successful cases, 67 had stents placed by fluoroscopy alone and 20 by a combined fluoroscopy/endoscopy procedure. Four percent had early complications (within 30 days) which included four perforations. There were late complications (over 30 days) in 9% which included five stent migrations, two blocked stents and one colovesical fistula. Ninety percent (n = 76) of the successful patients needed no further radiological or surgical intervention later. Survival ranged from 14 days to 2 years. Conclusion: Colorectal stenting when technically successful is an effective procedure for both preoperative and palliative decompression of colonic obstruction.

  20. Endoscopic placement of pancreatic stents and drains in the management of pancreatitis.

    Science.gov (United States)

    Kozarek, R A; Patterson, D J; Ball, T J; Traverso, L W

    1989-01-01

    Although widely used in the biliary tree, little data is available on endoscopic placement of stents or drains within the pancreas. This report describes 17 patients, nine with acute relapsing pancreatitis and eight with chronic pancreatitis, who had drain or stent placement for hypertensive pancreatic duct (PD) sphincter, dominant ductal stenosis, duct disruption, or pseudocyst. Two patients have subsequently undergone surgery, and six other patients continue long-term stent placement with marked reduction of chronic pain or attacks of recurrent pancreatitis. All six pseudocysts resolved, although one recurred and required surgery. It is concluded that pancreatic drains or stents may obviate the need for surgery, temporize before definitive therapy, or direct a subsequent surgical procedure. Images Figs. 1A and B. Figs. 2A-C. Figs. 2A-C. Fig. 3. Figs. 4A-D. Figs. 5A and B. PMID:2923512

  1. “Bare Metal” Stent Placement Complications: Interventional Treatment

    Directory of Open Access Journals (Sweden)

    Nita D.

    2016-11-01

    Full Text Available The rapid implementation of stents in standard practice and expansion of the indication for their utilization also introduced a new problem: in-stent restenosis. Management of patients with restenosis after stent implantation is still considered an important clinical problem. Although balloon angioplasty is still one of the prefered strategies that provide satisfactory results and a low incidence of complication, repeat stenting with “drug eluting” stents or “drug balloon” angioplasty become a very atractive methods of treatment for selected lesions and patients.

  2. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of University, Masan (Korea, Republic of); Jeong, Kyung Soon [University of Ulsan Colleg of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-09-15

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer.

  3. Percutaneous pancreatic stent placement for postoperative pancreaticojejunostomy stenosis: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Koo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Yoon, Chang Jin [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-09-15

    Stenosis of the pancreatico-enteric anastomosis is one of the major complications of pancreaticoduodenectomy (PD). Endoscopic stent placement, has limited success rate as a nonsurgical treatment due to altered gastrointestinal anatomy. Percutaneous treatment is rarely attempted due to the technical difficulty in accessing the pancreatic duct. We reported a case of pancreaticojejunostomy stenosis after PD, in which a pancreatic stent was successfully placed using a rendezvous technique with a dual percutaneous approach.

  4. Portal vein stent placement with or without varix embolization of jejunal variceal bleeding after hepatopancreatobiliary surgery.

    Science.gov (United States)

    Shim, Dong Jae; Shin, Ji Hoon; Ko, Gi-Young; Kim, Yook; Han, Kichang; Gwon, Dong-Il; Ko, Heung-Kyu

    2017-04-01

    Background Extrahepatic portal hypertension after surgery involving the duodenum or jejunum might result in massive ectopic variceal bleeding. Purpose To report the results of portal vein stent placement with the addition of variceal embolization. Material and Methods Between January 2000 and June 2015, portal vein stent placement was attempted in 477 patients. Of these, 22 patients (age, 63 ± 10 years) with jejunal variceal bleeding caused by portal vein obstruction after surgery were included in this study. Computed tomography (CT) findings before and after treatment and the rates of technical and clinical success, complications, and clinical outcomes were retrospectively evaluated. Results Stent placement was successful in 19 of 22 patients. Additional variceal embolization was performed in five cases. Clinical success, defined as the cessation of bleeding without recurrence within 1 month, was achieved in 18 of 19 patients with technical success. One patient developed recurrent bleeding 4 days after stent placement and was successfully treated with additional variceal embolization. There were no procedure-related complications. A regression of the jejunal varices was noted in 14 of 19 patients on follow-up CT scans. During the follow-up period (258 days; range, 7-1196 days), stent occlusion and recurrent bleeding occurred in six and four patients, respectively, of the 19 patients who achieved technical success. Statistical analyses revealed no significant differences regarding stent patency between benign and malignant strictures. Conclusion Percutaneous, transhepatic, portal vein stent placement with or without jejunal variceal embolization appears to be a safe and effective treatment for jejunal variceal bleeding after surgery.

  5. Osteonecrosis of Femoral Head Occurred after Stent Placement of Femoral Artery

    Directory of Open Access Journals (Sweden)

    Akiyoshi Shimatani

    2014-01-01

    Full Text Available We present a case of osteonecrosis of femoral head (ONFH that occurred after stent angiography of femoral artery for the treatment of arteriosclerosis obliterans (ASO of left inferior limb in a 76-year-old woman. No case of late collapse of femoral head as a complication of endovascular procedure such as stent placement has been previously documented. We considered that ONFH occurred after detaining stent at a junction of left deep femoral artery for the treatment of the ischemia of left lateral and medial femoral circumflex artery.

  6. Comparison of Surgical Outcome in Endoscopic Dacryocystorhinostomy with and without Silicon Stent Placement

    Directory of Open Access Journals (Sweden)

    Hardik Shah

    2013-02-01

    Full Text Available Objective: The purpose of this study was to compare the long term surgical outcome in endonasal dacrycystorhinostomy (DCR with and without silicon stent placement. Subjects and method: A retrospective comparative analysis of 129 patients who underwent primary endoscopic DCR with stenting (group A or without stenting (group B was done. Success was defined as grade 0 or grade 1 epiphora at minimum 6 months follow up and complete patency of the lacrimal drainage system confirmed by irrigation. Patients were followed up for mean 28 weeks, (range 6 months to 2 years. Stents were usually removed at about three to six months (mean 21 weeks. Results: Out of the 129 patients, 90 underwent silicon stent placement (group A as against 39 patients in which DCR was done without stenting (group B. Out of 90 patients of group A, 84 ( 93.33% showed complete recovery of symptoms (epiphora grading 0-1 Out of 39 patients of group B 35( 92.30% showed complete recovery of symptoms at six months follow up. Patients with stent placements showed a slightly higher rate of success as compared to patients without stenting (93.33%/ 92.30%. There was however no statistical difference in the success rate between group A and group B (p- 0.8086. Conclusion: Silicon intubation of the nasolacrimal duct may not contribute to the success of endonasal DCR. Other factors such as size of the rhinostomy and presence of infection also play an important role in success of endonasal DCR. [Natl J of Med Res 2013; 3(1.000: 34-37

  7. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com; Yamaguchi, Masato, E-mail: masato03310402@yahoo.co.jp [Kobe University Hospital, Department of Radiology (Japan); Muradi, Akhmadu, E-mail: muradiakhmadu@gmail.com; Nomura, Yoshikatsu, E-mail: y_katsu1027@yahoo.co.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Uotani, Kensuke, E-mail: uotani@tenriyorozu.jp [Tenri Hospital, Department of Radiology (Japan); Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Miyamoto, Naokazu, E-mail: naoka_zu@yahoo.co.jp; Kawasaki, Ryota, E-mail: kawaryo1999@yahoo.co.jp [Hyogo Brain and Heart Center at Himeji, Department of Radiology (Japan); Taniguchi, Takanori, E-mail: tan9523929@yahoo.co.jp [Tenri Hospital, Department of Radiology (Japan); Okita, Yutaka, E-mail: yokita@med.kobe-u.ac.jp [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji, E-mail: kojirad@med.kobe-u.ac.jp [Kobe University Hospital, Department of Radiology (Japan)

    2013-08-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 {+-} 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35-1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary.

  8. Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2013-06-15

    Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

  9. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    Directory of Open Access Journals (Sweden)

    Liberato Manuel José

    2012-08-01

    Full Text Available Abstract Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS and plastic stents (PS.We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS, functional success (FS, early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III. Results The initial stent insertion was successful in 450 (93.8% patients. TS was achieved in 204 (88.3% patients treated with PS and in 246 (98.8% patients palliated with SEMS (p P P  Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients.

  10. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  11. Bleeding after expandable nitinol stent placement in patients with esophageal and upper gastrointestinal obstruction: incidence, management, and predictors.

    Science.gov (United States)

    Oh, Se Jin; Song, Ho-Young; Nam, Deok Ho; Ko, Heung Kyu; Park, Jung-Hoon; Na, Han Kyu; Lee, Jong Jin; Kang, Min Kyoung

    2014-11-01

    Placement of self-expandable nitinol stents is useful for the treatment of esophageal and upper gastrointestinal (GI) obstruction. However, complications such as stent migration, tumor overgrowth, and bleeding occur. Although stent migration and tumor overgrowth are well documented in previous studies, the occurrence of bleeding has not been fully evaluated. To evaluate the incidence, management strategies, and predictors of bleeding after placement of self-expandable nitinol stents in patients with esophageal and upper GI obstruction. We retrospectively reviewed the medical records and results of computed tomography and endoscopy of 1485 consecutive patients with esophageal and upper GI obstructions who underwent fluoroscopically guided stent placement. Bleeding occurred in 25 of 1485 (1.7%) patients 0 to 348 days after stent placement. Early stent-related bleeding occurred in 10 patients (40%) and angiographic embolization was used for 5/10. Late bleeding occurred in 15 patients (60%) and endoscopic hemostasis was used for 7/15. Twenty-two of 25 (88%) patients with bleeding had received prior radiotherapy and/or chemotherapy. Bleeding is a rare complication after placement of expandable nitinol stents in patients with esophageal and upper GI obstruction, but patients with early bleeding may require embolization for control. Care must be exercised on placing stents in patients who have received prior radiotherapy or chemotherapy. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction

    NARCIS (Netherlands)

    S.M. Jeurnink (Suzanne); A. Repici (Alessandro); C. Luigiano (Carmelo); N. Pagano (Nico); E.J. Kuipers (Ernst); P.D. Siersema (Peter)

    2009-01-01

    textabstractBackground: Stent placement in the distal duodenum or proximal jejunum with a therapeutic gastroscope can be difficult, because of the reach of the endoscope, loop formation in the stomach, and flexibility of the gastroscope. The use of a colonoscope may overcome these problems. Objectiv

  13. Endoscopic transcystic stent placement for an intrahepatic abscess due to gallbladder perforation

    Institute of Scientific and Technical Information of China (English)

    Myung Soo Kang; Do Hyun Park; Ki Du Kwon; Jeong Hoon Park; Suck-Ho Lee; Hong-Soo Kim; Sang-Heum Park; Sun-Joo Kim

    2007-01-01

    Perforation of the gallbladder with cholecystohepatic communication is a rare cause of liver abscess. Because it is a rare entity, the treatment modality has not been fully established. We report for the first time a patient with an intrahepatic abscess due to gallbladder perforation successfully treated by endoscopic stent placement into the gallbladder who had a poor response to continuous percutaneous drainage.

  14. Results of the Ticlid or Plavix Post-Stents (TOPPS) trial: do they justify the switch from ticlopidine to clopidogrel after coronary stent placement?

    Science.gov (United States)

    Berger, Peter B

    2000-01-01

    In the Ticlid or Plavix Post-Stents (TOPPS) trial, 1016 patients undergoing successful coronary stent placement were randomized to receive aspirin and either ticlopidine or clopidogrel. In this trial, the dosages and regimens of ticlopidine and clopidogrel resembled more closely those used in most catheterization laboratories than did the two previous randomized trials comparing ticlopidine and clopidogrel. The results of the TOPPS trial support the current practice of substituting ticlopidine for clopidogrel in stent patients.

  15. Results of the Ticlid or Plavix Post-Stents (TOPPS trial: do they justify the switch from ticlopidine to clopidogrel after coronary stent placement?

    Directory of Open Access Journals (Sweden)

    Berger Peter B

    2000-10-01

    Full Text Available Abstract In the Ticlid or Plavix Post-Stents (TOPPS trial, 1016 patients undergoing successful coronary stent placement were randomized to receive aspirin and either ticlopidine or clopidogrel. In this trial, the dosages and regimens of ticlopidine and clopidogrel resembled more closely those used in most catheterization laboratories than did the two previous randomized trials comparing ticlopidine and clopidogrel. The results of the TOPPS trial support the current practice of substituting ticlopidine for clopidogrel in stent patients.

  16. Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Huei-Lung; Pan, Huay-Ben; Lin, Yih-Huie; Chen, Chiung-Yu; Lai, Pin-Hong; Yang, Chien-Fang [Kaohsiung Veterans General Hospital, Kaohsiung (China); Chung, Hsiao-Min; Wu, Tung-Ho; Chou, Kang-Ju [National Yangming University, Taipei (China)

    2006-06-15

    We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patents (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8-10mm in diameter and 40-80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates ({+-}standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69%{+-}9 and 88%{+-}6,41% {+-}10 and 88%{+-}6, 30%{+-}10 and 77%{+-}10, and 12%{+-}8 and 61%{+-}13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51%{+-}16 and 86%{+-}13 vs 45%{+-}15 and 73%{+-}13 at 6 months, and 25%{+-}15 and 71%{+-}17 vs 23%{+-}17 and 73%{+-}13 at 12 months ({rho} = .436 and .224), respectively. Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen.

  17. Percutaneous “Y” biliary stent placement in palliative treatment of type 4 malignant hilar stricture

    Science.gov (United States)

    Centore, Luca; Soreca, Emilio; Corvino, Antonio; Farbo, Vincenzo; Bencivenga, Alfonso

    2016-01-01

    Background This study evaluated the technical and clinical efficacy of percutaneous bilateral biliary stent-in-stent (SIS) deployment technique with a “Y” configuration using open-cell-design stents in type 4 Klatskin tumor patients. Methods Retrospective evaluation ten patients with type IV Bismuth malignant hilar stricture (MHS) treated with percutaneous bilateral “Y” SIS deployment technique placement followed in our institution between March of 2012 and November of 2014. Results Bilateral SIS deployment was technically successful in all patients. One patient (10%) had major complications (episode of cholangitis); one patient (10%) had minor complications, including self-limiting hemobilia. Successful internal drainage was achieved in nine (90%) patients. Stent occlusion by tumor overgrowth and sludge formation occurred in two patient (20%). The median survival and stent patency time were 298 and 315 days respectively. Conclusions Percutaneous bilateral metal stenting using a Y-stent is a valid option for the palliative treatment of type 4 Bismuth MHS, improving quality patient’ life. PMID:27034794

  18. Stent placement for palliation of cor triatriatum dexter in a dog with suspected patent foramen ovale.

    Science.gov (United States)

    Barncord, Kristin; Stauthammer, Christopher; Moen, Sean L; Hanson, Melissa; Gruenstein, Daniel H

    2016-03-01

    An 11 month old spayed, female dog presented with exercise intolerance and cyanosis upon exertion. Echocardiography revealed an imperforate cor triatriatum dexter with mild tricuspid valve dysplasia, an underfilled right ventricle and significant right to left shunting across a presumptive patent foramen ovale. Balloon dilation of the abnormal atrial membrane was initially successful in creating a communication between the right atrial chambers, but stenosis of the original perforation and persistent clinical signs prompted a second intervention. A balloon expandable biliary stent was placed across the abnormal partition, improving caudal venous return to the right ventricle and reducing the right to left shunt. Three months after stent placement, resting oxygen saturation had normalized. Six months after stent placement, exercise tolerance had improved and exertional cyanosis had resolved. Long term follow up will be necessary to assess for remodeling of the right ventricle with improved venous return. Stent placement can be considered as a palliative treatment option for cor triatriatum dexter, especially for stenosis post-balloon dilation.

  19. Combined Placement of Covered Self-Expanding Metallic Stents and Nasojejunal Tube for Managing Large Lower Esophageal Perforations.

    Science.gov (United States)

    Rana, Surinder S; Gupta, Rajesh; Dahiya, Divya; Behera, Arunanshu; Bhasin, Deepak K

    2014-02-01

    Covered self-expanding metallic stents (cSEMSs) have emerged as effective treatment option for esophageal perforations. However, the large lower esophageal perforations where the cSEMS is placed across gastroesophageal junction have lower healing rates because refluxed gastric contents constantly irritate perforation and also there is increased risk of stent migration. Moreover, gastric mucosa tends to prolapse into lumen of lower end of stent causing its obstruction, leading to seepage of saliva and fluids from upper end of stent even in the patients who are on parenteral nutrition. We present our experience of a novel technique of combined cSEMS and nasojejunal tube (NJT) placement in four patients (two males) with benign large lower esophageal perforations. The NJT was placed through the stent into the jejunum through which patients were given enteral feeding. The stents were placed 5 - 21 days after esophageal perforation with the size of perforation ranging from 4 to 6 cm. As the NJT formed a loop in stomach, it prevented migration of stent. And also its presence in lumen of stent prevented its obstruction by prolapsing gastric mucosa, thereby preventing seepage of saliva and fluids from side of stent. Both stents and NJT were removed after 6 weeks and leak closed in all patients. Combined cSEMS and NJT placement seems to be safe and effective for treating large lower esophageal perforations. NJT placement seems to decrease risk of migration, prevents seepage of fluids and permits early enteral nutrition, thereby improving the healing rates.

  20. Frequency of Stent Placement after Ureteroscopic Lithotripsy in a University and a State Hospital

    Directory of Open Access Journals (Sweden)

    Huseyin Celik

    2016-03-01

    Full Text Available Objective: The aim of this study was to compare frequen­cy of ureteral stent placement after ureteroscopic litho­tripsy in a university and a state hospital of two different cities, which are endemic in terms of stone and often ure­terolithotripsy was performed for urolithiasis treatment. Methods: The patients who applied in to urology clinic of Inonu University Turgut Ozal Medical Center (TOMC and urology clinic of Osmaniye State Hospital (OSH between January 2014 and May 2014 were evaluated retrospec­tively. The patients who underwent ureteroscopic lithotrip­sy due to ureteral stone, were evaluated stone locations, stone sizes, grades of pelvicaliectasia and ureteral stent placement status. Results: About 92 patients were enrolled into the study from the both hospital. After the endoscopic ureteral stone treatment, Double J stent was placed in 85 patients in TOMC (92.3% and 82 patients in OSH (89.1%. Stent im­plantation rate in the university hospital was higher than the state hospital but this was not statistically significant. There was a statistically meaningful difference in mean operative time between the 2 groups. Conclusion: Double J stent placament is recently per­formed too often after the endoscopic ureteral stone treat­ment. According to our study, university hospitals have a higher rate of incidence of double j stent placement ac­cording to state hospitals. It can be reason for that, uni­versity hospitals as the last line treatment centers, more complicated cases that refer to these centers. But in this matter, prospective, multicenter and larger series studies are needed.

  1. The Clinicaal and Angiograghic Outcome of 290 Cases after Stent Placement in Small Coronary Vessels

    Institute of Scientific and Technical Information of China (English)

    郭文怡; 贾国良; 李伟杰; 秦涛; 李成祥; 栾荣华; 吕安林; 王小燕; 李媛

    2003-01-01

    Objectives To invest the success procedure,immediate outcome after procedure,the rate of main adverse cardiac events after procedure and restenosis after stent placement in small coronary vessels. Methods 290 patients with selected or emergency stent implantation in small vessels from April, 1997 to March, 2002. Total 299 vessels, 304 lesions and 316 stents were statisted. The successs rate of procedure, immediate outcome after procedure, the rate of main adverse cardiac events after procedure and restenosis after stent placement in small coronary vessels were assessed. The patients were followed up l month to 4 years. Re-catheter angiography were done in 122/290 patients. Results The narrow rate of lesion dropped from 89% ± 12% before procedure to 5% ±5% after procedure (diameter). 202 patients were followed up 1 month(69.7% ). 197/202 cases were survival. 5/202 cases died in 3hrs to 7days. 2/5 cases died of persistent hypotension after procedure. 1/5 case died of acute left heart failure. 2/5 cases died of sudden death. 180 cases were followed up 5 months to 4 years. The non-event survival (NES) rate was 73.3% (132/180). The re-angiography were done in 122 cases. Restenosis happened in 39 cases (30.3%). 37 patients repeated PCI. 2 patients went to CABG. 2 cases got angina recurrence and were proved second time restenosis by re-angiography. The third time PCI was done in 1 patient. The other patients went to CABG. 1 case died of chronic heart failure after 2 years. 1 case suffered acute myocardial infarction on artery stent implanted. Conclusions There are high success rate of procedure and perfect immediate outcome in stent placement in small vessels.Main adverse cardiac events did not increased. Non-event survial was satisfied in long term follow - up.Restenosis rate was showed slightly higher than the one of main vessels.

  2. Percutaneous placement of self-expandable metallic stents in patients with obstructive janudice secondary to metastalic gastric cancer after gastrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Seo, In Ho; Yu, Jung Rim; Mok, Young Jae; Oh, Joo Hyeong [Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kwon, Se Hwan [Dept. of Radiology, Kyung Hee University Medical Center, Seoul (Korea, Republic of); Kim, Sam Soo [Dept. of Radiology, Kangwon National University College of Medicine, Chuncheon (Korea, Republic of); Kim, Seung Kwon [Division of Interventional Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis (United States)

    2013-10-15

    To evaluate the outcomes of patients undergoing percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy. Fifty patients (mean age, 62.4 years; range, 27-86 years) who underwent percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy were included. The technical success rate, clinical success rate, complication rate, stent patency, patient survival and factors associated with stent patency were being evaluated. The median interval between the gastrectomy and stent placement was 23.1 months (range, 3.9-94.6 months). The 50 patients received a total of 65 stents without any major procedure-related complications. Technical success was achieved in all patients. The mean total serum bilirubin level, which had been 7.19 mg/dL ± 6.8 before stent insertion, decreased to 4.58 mg/dL ± 5.4 during the first week of follow-up (p < 0.001). Clinical success was achieved in 42 patients (84%). Percutaneous transhepatic biliary drainage catheters were removed from 45 patients (90%). Infectious complications were noted in two patients (4%), and stent malfunction occurred in seven patients (14%). The median stent patency was 233 ± 99 days, and the median patient survival was 179 ± 83 days. Total serum bilirubin level after stenting was an independent factor for stent patency (p = 0.009). Percutaneous transhepatic placement of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy is a technically feasible and clinically effective palliative procedure.

  3. Clinical outcomes and risk factors for technical and clinical failures of self-expandable metal stent insertion for malignant colorectal obstruction.

    Science.gov (United States)

    Yoon, Jin Young; Jung, Yoon Suk; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2011-10-01

    Although self-expandable metal stent (SEMS) insertion is widely used for relief of malignant colorectal obstructions, the immediate technical and clinical failure rates of SEMSs and the associated risk factors remain largely unknown. To identify rates and factors predictive of technical and clinical failure of SEMSs when their use is attempted for the decompression of malignant colorectal obstruction. Retrospective chart review. A tertiary-care academic medical center in South Korea. This study involved a total of 412 patients with malignant colorectal obstruction in whom SEMS insertion was attempted. Placement of colonic SEMSs. Technical success and immediate and long-term clinical success rates. Technical and clinical failures were found in 36 of 276 patients (13.0%) and 39 of 240 patients (16.3%) in the palliative group, respectively, and in 3 of 136 patients (2.2%) and 7 of 133 patients (5.3%) in the preoperative group, respectively. Factors associated with technical failure were extracolonic origin of tumor, the presence of carcinomatosis, and a proximal obstruction site. Factors associated with long-term clinical failure in the palliative group were combined dilation procedure, no additional chemotherapy, and extracolonic origin of the tumor. In the preoperative group, only older patients had both higher technical failure and clinical failure rates. This was a single-institution, retrospective analysis. Although colorectal SEMS placement is generally safe and effective, it is associated with clinically important technical and clinical failure rates. The identification of risk factors for the failure of colorectal SEMSs found in this study might help physicians decide between surgical decompression and endoscopic stenting in patients with malignant colorectal obstruction. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  4. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  5. PTA and stent placement distal to the superficial femoral artery; PTA und Stent distal der AFS

    Energy Technology Data Exchange (ETDEWEB)

    Rand, T.; Stadler, A.; Schoder, M.; Kettenbach, J. [Medizinische Universitaet Wien, Klinische Abteilung fuer Angiographie und Interventionelle Radiologie, Wien (Austria); Haumer, M. [Klinik fuer Innere Medizin II des Universitaetsklinikums Wien, Klinische Abteilung fuer Angiologie, Wien (Austria)

    2006-11-15

    Although angioplasty and stent applications in the iliac vessels and the superficial femoral artery have become routine procedures, their usefulness for the treatment of lesions of the popliteal artery and the lower leg arteries is still under discussion. For the popliteal artery, limitations are mainly due to the high mechanical stress in this area, causing high traction forces. Moreover, beyond the occlusive atherosclerotic changes, specific pathological entities such as aneurysms, emboli, entrapment syndromes, and cystic adventitial disease have to be differentiated. There is hope that the development of innovative stent designs with high flexibility might overcome the limitations. For lesions of the lower leg arteries treatment with percutaneous transluminal angioplasty (PTA) has become the method of choice. However, stent designs as used for cardiac interventions have been adapted for their application below the knee, and first encouraging results may help to justify their broad use in the future. Regarding PTA, innovative equipment and techniques for the treatment of arterial lesions below the knee include dedicated, long, and very flexible balloons, cutting balloon cryoplasty, and laser angioplasty. Regarding stents, bare metal stents, stents with passive or active coatings, and bioabsorbable stents have all been successfully used. (orig.) [German] Waehrend Angioplastie (PTA) und Stentbehandlung im Bereich der Beckengefaesse sich zu etablierten interventionellen Standardverfahren entwickelt haben, ist die endovaskulaere Behandlung von Laesionen der A. poplitea und auch der Unterschenkelgefaesse noch in Diskussion. Gruende hierfuer sind bei der A. poplitea v. a. die unguenstigen mechanischen Faktoren, die hohe Traktionskraefte am Gefaess wirken lassen und besonders die Gefaesspathologien, die neben der stenosierenden Atherosklerose auch andere spezifische Auspraegungen wie Aneurysmen, Embolien, Entrapmentsyndrome und die zystische Adventitianekrose umfassen

  6. Carotid angioplasty and stent placement for restenosis after endarterectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kadkhodayan, Yasha [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Moran, Christopher J.; Cross, DeWitte T. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Derdeyn, Colin P. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States)

    2007-04-15

    Recurrent carotid stenosis following endarterectomy is a common complication, and reoperation may be associated with increased morbidity. The goal of this study was to determine the procedural safety and long-term complication rates of carotid angioplasty and stenting for recurrent stenosis. Of 248 consecutive carotid angioplasty and/or stenting procedures performed at our institution between March 1996 and November 2005, 83 procedures for recurrent stenosis following endarterectomy were performed in 75 patients (mean age 68 years; 43 men, 32 women) without cerebral protection devices. The patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and long-term complication rates were calculated. Recurrent stenosis was reduced from a mean of 80.6% to no significant stenosis in 82 of 83 procedures. The procedural stroke rate was 3 out of 83 procedures (3.6%). The procedural transient ischemic attack (TIA) rate was 2 out of 83 procedures (2.4%). Mean follow-up was 22.4 months (range 0.1 to 86.7 months) with at least 6 months follow-up for 54 of 83 procedures (65%). There were five TIAs and no strokes on follow-up (new TIAs at 25.5 and 43.4 months; recurrent TIAs at 1, 11.1, and 12 months, all with normal angiograms). The composite 30-day stroke, myocardial infarction, or death rate was 5 of 83 procedures (6.0%). In this series, angioplasty and stenting were effective in relieving stenosis secondary to recurrent carotid disease after endarterectomy, and have low rates of ischemic complications. (orig.)

  7. Transfundal stent placement for treatment of complex basilar tip aneurysm: technical note

    Science.gov (United States)

    Vasquez, Ciro; Hubbard, Molly; Jagadeesan, Bharathi Dasan; Tummala, Ramachandra Prasad

    2014-01-01

    We describe a case where a complex unruptured basilar tip aneurysm was treated with a unique method of stent-assisted coil embolization. The aneurysm was considered to have a complex anatomy since both the left posterior cerebral artery and left superior cerebellar artery originated from the dome of the aneurysm. Also, the right posterior cerebral artery was incorporated in the aneurysm neck and needed to be protected prior to coil embolization. This case describes placement of a stent across the span of the aneurysm fundus in order to preserve the two branches arising from it, and the aneurysm dome was coiled without any complication. Using modifications of existing strategies for stent-assisted coil embolization, the aneurysm was treated without any complications and all of the vessels at risk were preserved. PMID:25336546

  8. Process mapping of PTA and stent placement in a university hospital interventional radiology department.

    Science.gov (United States)

    de Bucourt, Maximilian; Busse, Reinhard; Güttler, Felix; Reinhold, Thomas; Vollnberg, Bernd; Kentenich, Max; Hamm, Bernd; Teichgräber, Ulf K

    2012-08-01

    To apply the process mapping technique in an interdisciplinary approach in order to visualize, better understand, and efficiently organize percutaneous transluminal angioplasty (PTA) and stent placement procedures in a university hospital's interventional radiology department. After providing an overview of seven established mapping techniques for medical professionals, the process mapping technique was chosen and applied in an interdisciplinary approach including referrers (physicians, nurses, and other staff in referring departments, e.g., vascular surgery), providers (interventional radiologists, nurses, technicians, and staff of the angiography suite), and specialists of the hospital's controlling department. A generally binding and standardized process map was created, describing the entire procedure for a patient in whom the radiological intervention of PTA or stent treatment is contemplated from admission to the department of vascular surgery until discharge after successful treatment. This visualization tool assists in better understanding (especially given natural staff fluctuation over time) and efficiently organizing PTA and stent procedures. Process mapping can be applied for streamlining workflow in healthcare, especially in interdisciplinary settings. By defining exactly what a business entity does, who is responsible, to what standard a process should be completed, and how the success can be assessed, this technique can be used to eliminate waste and inefficiencies from the workplace while providing high-quality goods and services easily, quickly, and inexpensively. Process mapping can be used in a university hospital's interventional radiology department. • Process mapping can describe the patient's entire process from admission to PTA/stent placement until discharge. • Process mapping can be used in interdisciplinary teams (e.g., referrers, providers, and controlling specialists). • Process mapping can be used in order to more efficiently

  9. How to decide on stent insertion or surgery in colorectal obstruction?

    Science.gov (United States)

    Zahid, Assad; Young, Christopher John

    2016-01-27

    Colorectal cancer is one of the most common cancers in western society and malignant obstruction of the colon accounts for 8%-29% of all large bowel obstructions. Conventional treatment of these patients with malignant obstruction requiring urgent surgery is associated with a greater physiological insult on already nutritionally replete patients. Of late the utility of colonic stents has offered an option in the management of these patients in both the palliative and bridge to surgery setting. This has been the subject of many reviews which highlight its efficacy, particulary in reducing ostomy rates, allowing quicker return to oral diet, minimising extended post-operative recovery as well as some quality of life benefits. The uncertainity in managing patients with malignant colonic obstructions has lead to a more cautious use of stenting technology as community equipoise exists. Decision making analysis has demonstrated that surgeons' favored the use of stents in the palliative setting preferentially when compared to the curative setting where surgery was preferred. We aim to review the literature regarding the use of stent or surgery in colorectal obstruction, and then provide a discourse with regards to the approach in synthesising the data and applying it when deciding the appropriate application of stent or surgery in colorectal obstruction.

  10. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis

    Institute of Scientific and Technical Information of China (English)

    Hong Shan; Xiang-Sheng Xiao; Ming-Sheng Huang; Qiang Ouyang; Zai-Bo Jiang

    2005-01-01

    AIM: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis.METHODS: Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated.RESULTS: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3±4.7) cm H2O to (18.0±1.9) cm H2O. The portal blood flow restoredand the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. CONCLUSION: Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  11. Residual stenosis after conventional balloon angioplasty for hemodialysis shunt failure: treatment with metallic stent placement and post-balloon dilatation.

    Science.gov (United States)

    Kariya, Shuji; Tanigawa, Noboru; Kojima, Hiroyuki; Komemushi, Atsushi; Shiraishi, Tomokuni; Kawanaka, Toshiaki; Sawada, Satoshi

    2005-02-01

    The usefulness of metallic stent placement and post-balloon dilatation was investigated for patients with residual stenosis after conventional percutaneous transluminal balloon angioplasty (balloon PTA) of dialysis shunt vessels. Among 92 patients who had received balloon PTA for dialysis shunt vessels, seven patients who showed a residual waist on the balloon even under maximum inflation were enrolled in this study. In these patients with residual stenosis after balloon PTA, we inserted a stent in the residual stenosis, and post-balloon dilatation was immediately applied using the same balloon catheter. After balloon PTA, the average percent diameter stenosis declined to 45.5 +/- 7.30%, and the stenosis was further improved to an average of 19.3 +/- 7.09% after the placement of a stent and the additional balloon PTA. The average percent diameter dilatation of the balloon before the placement of a stent was 65.8 +/- 12.7%, while the average dilatation increased to 84.1 +/- 8.96% after the placement of a stent. Dialysis became possible immediately after the procedure in all cases. Metallic stent placement and post-balloon dilatation was effective for patients with residual stenosis after conventional balloon PTA of dialysis shunt vessels.

  12. Endoscopic placement of double-J ureteric stents in children as a treatment for primary obstructive megaureter

    Directory of Open Access Journals (Sweden)

    Carroll Daniel

    2010-01-01

    Full Text Available Aim: To determine the efficacy and potential complications of double-J ureteric stents in the treatment of persistent or progressive primary obstructive megaureter in pediatric patients within our institution. Materials and Methods: A retrospective case-note review of all patients with double-J ureteric stents, between 1997 and 2004, was performed. In all, 38 stents were inserted in 31 patients aged between 2 months and 15 years of age. Complications and results of follow-up investigations and the need for follow-up investigations were recorded. Patients were followed up clinically and radiologically for a minimum of 2 years following stent insertion. Results: Endoscopic placement of double-J ureteric stents in childhood is straightforward and complications are uncommon (8/38 insertions. In non-resolving or progressive primary non-refluxing megaureter, double-J ureteric stenting alone is effective with resolution of primary non-refluxing megaureter in 66% of cases (25/38 insertions. Conclusions: Ureteric stenting provides an alternative to early surgery in patients with primary non-refluxing megaureter. The youngest patient in our series was 2 months old at the time of endoscopic ureteric double-J stent insertion. Endoscopic placement of ureteric double-J stents should be considered as a first-line treatment in the management of persistent or progressive non-refluxing megaureter leading to progressive hydronephrosis or pyonephrosis.

  13. Treatment of benign biliary leaks with transhepatic placement of coated self-expanding metallic stents.

    Science.gov (United States)

    Páramo, M; García-Barquín, P; Carrillo, M; Millor Muruzábal, M; Vivas, I; Bilbao, J I

    To analyze the safety and efficacy of percutaneous placement of coated self-expanding metallic stents (SEMS) in patients with biliary leaks. This ethics committee at our center approved this study. We retrospectively reviewed all coated SEMS placed between October 2008 and September 2015. We analyzed patient-related factors such as the primary underlying disease, prior hepatic procedures, and clinical outcome. We evaluated the location, the number and type of leak (anastomotic or non-anastomotic), and the characteristics of the interventional procedure (number of stents deployed, location of the stents, technical success, and primary functionality). We recorded the complications registered. We studied 14 patients (11 men and 3 women). The mean follow-up period was 375.5 days (range 15-1920 days). Leaks were postsurgical in 12 patients. One patient developed an arteriobilioportal fistula. In another, the biliary leak occurred secondary to the rupture of the common bile duct after ERCP. A total of 23 coated SEMS were placed, including 21 Fluency(®) stents (Bard, Tempe, AZ, USA) and 2 Wallflex(®) stents (Boston Scientific, Galway, Republic of Ireland). The technical success of the procedure was considered total in 11 (78.6%) patients, partial in 2 (14.3%) patients, and null in 1 (7.2%) patient. The clinical outcome was good in 13 of the 14 patients. The mean period of primary functionality of the coated SEMS was 331 days (range 15-1920 days). No major complications were observed in 11 (78.6%) patients. Percutaneous placement of coated SEMS for the treatment of benign biliary leaks is safe and efficacious, with a high rate of technical and clinical success and a moderate rate of complications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Rescue AVE Stent Placement for Left Anterior Descending Coronary Artery Occlusion During Diagnostic Angiography.

    Science.gov (United States)

    van Dijk D; Ernst; Six; Plokker

    1996-06-01

    In a 65-year-old male with coronary artery disease a proximal occlusion of the left anterior descending coronary artery occurred during diagnostic coronary angiography. The most likely cause was an occlusive dissection. This resulted in acute myocardial ischemia and immediate cardiogenic shock. The decision was made to proceed to emergency percutaneous transluminal coronary angioplasty (PTCA). After balloon dilatation, a 3.5 mm AVE stent was deployed successfully at the site of the lesion. This resulted in a satisfactory angiographic result and an immediate improvement of the clinical picture. We conclude that placement of an AVE stent can provide a means for restoring flow in case of acute occlusive dissection during coronary angiography.

  15. Laparotomy enables retrograde dilatation and stent placement for malignant esophago-respiratory fistula

    Directory of Open Access Journals (Sweden)

    Iskender Özcan

    2008-01-01

    Full Text Available Abstract Background Malignant esophageal stenosis with complete obstruction and esophagorespiratory fistula (ERF is difficult to treat with standard endoscopic techniques. Case presentation We report a patient in whom with local recurrence of esophageal carcinoma an esophagotracheal fistula occurred. Initially the patient had undergone esophageal resection with interposition of a gastric tube. Due to complete obstruction of the lumen by recurrent tumor conventional transoral stent placement failed. For retrograde dilatation a laparotomy was performed. Via a duodenal incision endoscopic access to the gastric tube was achieved. Using a guidewire the esophageal obstruction was traversed and dilated. Then it was possible to place an esophageal stent via an antegrade approach. Conclusion Open surgery enables a safe access for retrograde endoscopic therapy in patients who had undergone esophageal resection with gastric interposition.

  16. Examination of Physicians’ Perception of the Indications of Colorectal Stents in the Management of Malignant Large Bowel Obstruction: A Provincial Survey

    Directory of Open Access Journals (Sweden)

    Jean-Frédéric LeBlanc

    2016-01-01

    Full Text Available Introduction. Data are conflicting when assessing indications for colorectal self-expandable metallic stents (SEMS in managing acute malignant large bowel obstruction (MLO. In November 2014, European and American Societies published guidelines to aid in understanding which patients might benefit from colorectal stenting. Yet, there remain marked disparities in clinical practice. Methods. A web-based survey was sent to Gastroenterologists and Surgical Specialists across Quebec to assess physicians’ knowledge and adherence to the indications for colonic SEMS placement in the management of MLO using eight clinical scenarios. Results. Out of 112 respondents, 74% preferred surgical intervention in young, healthy individuals with MLO. Advanced age and comorbidities motivated 56.3% (95% CI 47.1–65.5% of participants to opt for SEMS placement. In palliative settings of patients undergoing chemotherapy including bevacizumab, a minority of respondents followed guidelines, 12.5% (95% CI 6.4–18.6% for young patients and 25.0% for elderly patients (95% CI 17.0–33.0%. The pooled overall adherence to guidelines was 50.4% (95% CI 40.7–59.3%. Conclusion. This survey suggests that guidelines recommendations are not being implemented by at least half of specialists involved in the care of patients with MLO. Future studies should attempt to identify possible barriers responsible for this impaired knowledge translation and tailored educational initiatives planned accordingly.

  17. Examination of Physicians' Perception of the Indications of Colorectal Stents in the Management of Malignant Large Bowel Obstruction: A Provincial Survey

    Science.gov (United States)

    2016-01-01

    Introduction. Data are conflicting when assessing indications for colorectal self-expandable metallic stents (SEMS) in managing acute malignant large bowel obstruction (MLO). In November 2014, European and American Societies published guidelines to aid in understanding which patients might benefit from colorectal stenting. Yet, there remain marked disparities in clinical practice. Methods. A web-based survey was sent to Gastroenterologists and Surgical Specialists across Quebec to assess physicians' knowledge and adherence to the indications for colonic SEMS placement in the management of MLO using eight clinical scenarios. Results. Out of 112 respondents, 74% preferred surgical intervention in young, healthy individuals with MLO. Advanced age and comorbidities motivated 56.3% (95% CI 47.1–65.5%) of participants to opt for SEMS placement. In palliative settings of patients undergoing chemotherapy including bevacizumab, a minority of respondents followed guidelines, 12.5% (95% CI 6.4–18.6%) for young patients and 25.0% for elderly patients (95% CI 17.0–33.0%). The pooled overall adherence to guidelines was 50.4% (95% CI 40.7–59.3%). Conclusion. This survey suggests that guidelines recommendations are not being implemented by at least half of specialists involved in the care of patients with MLO. Future studies should attempt to identify possible barriers responsible for this impaired knowledge translation and tailored educational initiatives planned accordingly.

  18. Safety and efficacy of stent placement for treatment of intracranial aneurysms: a systematic review

    Institute of Scientific and Technical Information of China (English)

    YANG Peng-fei; HUANG Qing-hai; ZHAO Wen-yuan; HONG Bo; XU Yi; LIU Jian-min

    2012-01-01

    Objective To evaluate the safety and efficacy of stent placement for the treatment of complex intracranial aneurysms.Data sources We searched six databases,including Pubmed,Embase,SCI-expanded,the Cochrane Library,ISI Proceedings and ProQuest Dissertations & Theses for the relevant studies using multiple key words from December,1997 to February,2009.Study selection Thirty-three studies about stent placement for intracranial aneurysms were identified,which reported data from a total of 1069 patients with 1121 intracranial aneurysms.Data extraction We prepared a standardized data extraction form (DEF),which was used by two independent researchers to extract data from the included 33 studies.Results The overall initial complete occlusion rate was 52.5% (456/869,95% CI:49.2%-55.8%).The overall complication rate was 14.3% (162/1130,95% CI:12.3%-16.4%),of which 3.6% (38/1044,95% CI:2.5%-4.8%) were permanent.Clinical follow-up showed a dependence rate of 8.4% (39/465,95% CI:5.9%-10.9%).Angiographic follow-up showed an improvement rate of 24.3% (117/481,95% CI:20,5%-28.2%) and a recurrence rate of 12.9% (62/481,95% CI:9.9%-15.9%).Chi-squared tests were performed to compare the following subgroups:self-expandable vs.balloon-expandable stents,unruptured vs.acutely ruptured aneurysms,and with vs.without pre-medication.Statistical significance was reached in eight tests.Conclusions Intracranial stent is a safe and effective tool for embolizing complex intracranial aneurysms.Self-expandable stents are significantly easier and safer than balloon-expandable stents with respect to navigation and deployment through the tortuous cerebral vasculature.Patients with acutely ruptured aneurysms are more likely to be deoendent,but not more likely to suffer more procedure-related complications.

  19. Outcome of endoscopic self-expandable metal stents in acute malignant colorectal obstruction at a tertiary center

    Directory of Open Access Journals (Sweden)

    Eduardo Rodrigues-Pinto

    2015-09-01

    Full Text Available Background: Malignant colorectal obstruction (MCRO by advanced colonic cancer occurs in 8-13% of colonic cancer patients. Emergent surgery carries a high mortality and morbidity risk. Endoscopic self-expanding metal stents (SEMS may be used in acute MCRO. Aim: Evaluate clinical outcome of SEMS in acute MCRO and efficacy of SEMS placement considering fluoroscopy guidance. Methods: Retrospective study of patients with acute MCRO that placed SEMS in a 3 years period. Results: SEMS were placed in 47 patients, followed-up for a median time of 150 days. The intent of stenting was bridge to definitive surgery in 40% of the patients (n = 19 and palliation in the remaining 60% (n = 28. The location of the tumor did not influence the presence of lymph node involvement (p = 0.764 nor metastasis (p = 0.885. Mortality rate at year 1 was 61%. Survival was significantly higher in patients submitted later to combination therapy compared to chemotherapy, surgery or symptomatic treatment (p < 0.001. Fluoroscopy was used in 57% of the procedures. Clinical success was 79%. A second SEMS was needed during the procedure in 6% of the patients. Rate of early and late complications was 11% and 5%, respectively. Fluoroscopy guidance did not influence the occurrence of immediate (p = 0.385, early (p = 0.950 or late complications (p = 0.057. Thirty-three percent of patients underwent surgery at a later stage, with neo-adjuvant therapy in 18%. Conclusions: SEMS provide a relative safe and successful treatment in a palliative or bridge-to-surgery indication. No significant differences were found in SEMS placement success, early complications or late complications considering fluoroscopy guidance.

  20. Endovascular Treatment of Blunt Traumatic Abdominal Aortic Occlusion With Kissing Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp; Yamaguchi, Masato; Okada, Takuya [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan); Nomura, Yoshikatsu [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimura, Kazuro [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan); Okita, Yutaka [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan)

    2012-10-15

    Blunt traumatic abdominal aortic dissection is extremely rare and potentially deadly. We present the case of a 62-year-old man involved in a frontal car crash. After emergency undergoing laparotomy for bowel injuries, he was referred to our hospital due to acute ischemia of bilateral lower extremities on day 3 after the trauma. Computed tomography and aortography showed an aortobiiliac dissection with complete occlusion. This injury was successfully treated by endovascular treatment with 'kissing'-technique stent placement, which appears to be a safe, effective, and minimally invasive treatment.

  1. Stent placement for chronic iliac arterial occlusive disease: the results of 10 years experience in a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Bo; Do, Young Soo; Kim, Dong Ik; Kim, Duk Kyung; Kim, Young Wook; Shin, Sung Wook; Cho, Sung Ki; Choo, Sung Wook; Choe, Yeon Heyon; Choo, In Wook [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jae Hyung; Han, Yoon Hee [Inje Univ., Kimhae (Korea, Republic of)

    2005-12-15

    We wanted to retrospectively evaluate the long-term therapeutic results of iliac arterial stent placement that was done in a single institution for 10 years. From May 1994 to April 2004, 206 patients who underwent iliac arterial stent placement (mean age; 64 {+-} 8.8) were followed up for evaluating the long term stent patency. Combined or subsequent bypass surgery was performed in 72 patients. The follow up period ranged from one month to 120 months (mean; 31 {+-} 25.2 months). The factors that were analyzed for their effect on the patency of stents were age, the stent type and diameter, the lesion site, lesion shape, lesion length, the Society of Cardiovascular and Interventinal Radiology criteria, the total run off scores, the Fontaine stage and the cardiovascular risk factors (diabetes mellitus, hypertension and smoking). Follow-up included angiography and/or CT angiography, color Doppler sonography and clinical evaluation with the ankle-brachial index. Two hundred and eighty-four stents were placed in 249 limbs of 203 patients. The technical success rate was 98% (203/206). The primary patency rates of the stents at 3, 5, 7 and 10 year were 87%, 83%, 61% and 49%, respectively. One hundred seventy-seven patients maintained the primary stent patency until the final follow up and 26 patients showed stenosis or obstruction during the follow up. Secondary intervention was performed in thirteen patients. Lesions in the external iliac artery (EIA) or lesions in both the common iliac artery (CIA) and EIA were a poor prognostic factor for stent patency. The run off score and stent diameter also showed statistically significant influence on stent patency. The overall complication rate was 6%. Iliac arterial stent placement is a safe treatment with favorable long term patency. Lesions in the EIA or lesions in both the EIA and CIA, poor run off vessels and a stent having the same or a larger diameter than 10 mm were the poor prognostic factors for long term stent patency.

  2. A 5-fluorouracil-loaded polydioxanone weft-knitted stent for the treatment of colorectal cancer.

    Science.gov (United States)

    Li, Gang; Chen, Yufeng; Hu, Jun; Wu, Xiaojian; Hu, Junyan; He, Xiaowen; Li, Jiashen; Zhao, Zheng; Chen, Zexian; Li, Yuling; Hu, Hong; Li, Yi; Lan, Ping

    2013-12-01

    In-stents restenosis caused by tumour ingrowth is a major problem for patients undergoing stent displacement because the conventional stents often lack a sustained anti-tumour capability. The aim of this paper was to develop a weft-knitted polydioxanone stent which can slow release 5-fluorouracil (5-FU). In order to determine the most suitable drug concentration, the 5-FU safe concentration in vivo and appropriate loading percentage in the membranes were investigated, and then 5-FU-loaded poly-l-lactide membranes at concentration of 3.2%, 6.4% and 12.8% were coated onto the stent using electro-spinning method, respectively. The morphology, chemical structure and in vitro drug release property of the coating membranes were subsequently examined. Their anti-tumour activity and mechanism were assessed in vitro and in vivo using a human colorectal cancer cell line HCT-116 and tumour-bearing BALB/c nude mice. The half maximal inhibitory concentration (IC50) and the median lethal dose (LD50) demonstrated that the 6.4% and 12.8% membranes had better anti-tumour effects than pure 5-FU due to the sustainable drug releasing property of the coated membranes on the stent. The membranes possessing appropriate drug loading doses, such as 6.4% or 12.8% also provided better anti-in-stents restenosis effects than other groups tested. Therefore, it is concluded that the drug-loaded stents have great potential for the use in the treatment of intestinal cancers in the future.

  3. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  4. Percutaneous ureteral stent placement for the treatment of a benign ureteral obstruction in a Sumatran tiger (Panthera tigris sumatrae).

    Science.gov (United States)

    Delk, Katie W; Wack, Raymund F; Burgdorf-Moisuk, Anne; Palm, Carrie A; Zwingenberger, Allison; Glaiberman, Craig B; Ferguson, Kenneth H; Culp, William T N

    2015-01-01

    A 15-year-old, 113 kg intact male Sumatran tiger (Panthera tigris sumatrae) was evaluated for weight loss, polydipsia, and intermittent hematuria. The tiger was immobilized for diagnostic testing including blood work, urinalysis, and abdominal ultrasound. Laboratory testing demonstrated macro- and microhematuria, azotemia, and an increased urine protein:creatinine ratio. Abdominal ultrasound revealed bilateral ureterolithiasis as well as hydronephrosis and ureteral dilation. Ultrasonography performed 5 months later revealed worsening of the right-sided hydronephrosis and hydroureter and a decrease in the severity of dilation on the left side presumably from passage of the left-sided ureteral calculi. Nephroureteral decompression via the placement of a stent was elected. A pigtail ureteral catheter (8.2 French diameter) was placed in the right ureter via an antegrade percutaneous approach utilizing ultrasound and fluoroscopic-guidance. Following stent placement, macrohematuria resolved although microhematuria was noted in opportunistic urine samples. Five months after stent placement, the azotemia had mildly progressed, the urine protein:creatinine ratio was improved, the right hydronephrosis and hydroureter had completely resolved, and the ureteral stent remained in the appropriate position. The tiger had clinically improved with a substantial increase in appetite, weight, and activity level. Ureteral stenting allowed for nephroureteral decompression in the captive large felid of this report, and no complications were encountered. Ureteral stenting provided a minimally invasive method of managing ureteral obstruction in this patient and could be considered in future cases due to the clinical improvement and low morbidity.

  5. Clinical safety of cardiac magnetic resonance imaging at 3 T early after stent placement for acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Jehl, Jerome; Comte, Alexandre; Aubry, Sebastien; Kastler, Bruno [Hopital Jean Minjoz, Service de Radiologie A and C, Centre Hospitalier Universitaire de Besancon, Besancon (France); Meneveau, Nicolas; Schiele, Francois [Hopital Jean Minjoz, Service de Cardiologie, Centre Hospitalier Universitaire de Besancon, Besancon (France)

    2009-12-15

    The purpose of this study was to prospectively evaluate the safety of cardiac magnetic resonance (CMR) imaging at 3 T performed early (less than 14 days) after bare metal or drug-eluting coronary stent implantation in patients with acute myocardial infarction (AMI). Seventy-two consecutive patients with AMI treated by percutaneous revascularisation with a stent underwent CMR examination with a median delay of 6 days. Patients were followed-up for major adverse cardiac events, during hospitalisation and at 6 months. After CMR imaging, no acute stent thrombosis, death or repeated AMI were recorded at 6-month follow-up. Two symptomatic in-stent restenoses and two silent in-stent restenoses were recorded, at a mean delay of 106 days. In our population, we found a target revascularisation rate of 5.6%. This is consistent with the 6-month event rates after coronary artery stent (CAS) placement for AMI, evaluated by several studies. This preliminary clinical study supports the safety of 3-T CMR imaging performed early after coronary stent placement. (orig.)

  6. Impact of Carcinomatosis on Clinical Outcomes after Self-Expandable Metallic Stent Placement for Malignant Gastric Outlet Obstruction.

    Directory of Open Access Journals (Sweden)

    Ji Eun Lee

    Full Text Available It is still unclear whether the peritoneal carcinomatosis had a negative effect on the clinical outcomes of patients who underwent self-expandable metallic stent (SEMS placement for malignant gastric outlet obstruction (GOO. Although carcinomatosis may be associated with the development of multifocal gastrointestinal (GI tract obstruction or decreased bowel movement, previous studies investigated the occurrence of stent failure only and thus had limitation in evaluating clinical outcomes of patients with carcinomatosis.Between 2009 and 2013, 155 patients (88 patients without carcinomatosis and 67 patients with carcinomatosis underwent endoscopic SEMS placement for malignant GOO. Factors affecting clinical success and obstructive symptom-free survival (time period between SEMS placement and the recurrence of obstructive symptoms due to multifocal GI tract obstruction or decreased bowel movement as well as stent failure were assessed.Patients with carcinomatosis showed higher Eastern Cooperative Oncology Group (ECOG scale than those without carcinomatosis. Clinical success rates were 88.1% in patients with carcinomatosis and 97.7% in patients without carcinomatosis. In multivariate analysis, only ECOG scale was identified as an independent predictor of clinical success. During follow-up period, patients with carcinomatosis showed significantly shorter obstructive symptom-free survival than those without carcinomatosis. In multivariate analysis, the presence of carcinomatosis, chemotherapy or radiation therapy after SEMS placement, and obstruction site were identified as independent predictors of obstructive symptom-free survival. For patient without carcinomatosis, stent failure accounted for the recurrence of obstructive symptoms in 84.6% of cases. For patients with carcinomatosis, multifocal GI tract obstruction or decreased bowel movement accounted for 37.9% of cases with obstructive symptom recurrence and stent failure accounted for 44.8% of

  7. Endovascular stent-graft placement and secondary intervention for abdominal aortic aneurysm in a patient who had a previously inserted iliac stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Yong Sun; Cho, Soon Gu; Hong, Kee Chun [Inha University College of Medicine, Incheon (Korea, Republic of)

    2007-04-15

    Endovascular repair of abdominal aortic aneurysm is associated with low morbidity and mortality rates when compared to open surgery, and this can be used in patients who are at a high risk for open surgical repair. Also, secondary intervention is an important for achieving intermediate and long term success of endovascular repair of abdominal aortic aneurysm as this can resolve complications. We report here on endovascular stent-graft placement and a secondary interventional procedure in the abdominal aortic aneurysm of a patient who had a previously inserted iliac stent.

  8. Colorectal stenting as a bridge to surgery reduces morbidity and mortality in left-sided malignant obstruction: a predictive risk score-based comparative study.

    Science.gov (United States)

    Cennamo, Vincenzo; Luigiano, Carmelo; Manes, Gianpiero; Zagari, Rocco Maurizio; Ansaloni, Luca; Fabbri, Carlo; Ceroni, Liza; Catena, Fausto; Pinna, Antonio Daniele; Fuccio, Lorenzo; Mussetto, Alessandro; Casetti, Tino; Coccolini, Federico; D'Imperio, Nicola; Bazzoli, Franco

    2012-06-01

    The Physiological and Operative Severity Score for the enUmeration of Mortality and morbidity model, and its Portsmouth and colorectal modifications are used to predict postoperative mortality and morbidity after colorectal surgery. To compare stent placement as a bridge to surgery vs. emergency surgical resection in patients with acute left-sided colorectal cancer obstruction using P-POSSUM and CR-POSSUM. From January 2008 to December 2009, the physiological and operative scores, morbidity and mortality predicted by the P-POSSUM and CR-POSSUM scores were collected in all consecutive patients with LCCO who underwent surgical resection directly (Group A) or after stent placement (Group B). Eighty-six patients were enrolled (Group A-41 and Group B-45). The observed 30-day mortality rate was 9.8% (4/41) in Group A and 2.4% (1/45) in Group B. The 30-day morbidity rate was 61% (25/41) in Group A and 29% (13/45) in Group B. The mean values of P-POSSUM morbidity (A=70.5% vs. B=34.3%; p=0.001), P-POSSUM mortality (A=13.6% vs. B=2.4%; p=0.001) and CR-POSSUM mortality (A=15.1% vs. B=4.9%; p=0.001) were significantly lower in the Group B patients than in the Group A patients. Bridge to surgery strategy reduces the surgical risks in LCCO, and P-POSSUM and CR-POSSUM scores represent a good tool for comparing the two strategies. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  9. Management of urine leak after laparoscopic cyst decortication with retrograde endoscopic fibrin glue application and ureteral stent placement.

    Science.gov (United States)

    Chen, Mang L; Tomaszewski, Jeffrey J; Matoka, Derek J; Ost, Michael C

    2011-01-01

    Urine leakage is an uncommon complication after renal cyst decortication that typically resolves with adequate drainage. With prolonged large volume urine leakage from a perinephric drain, however, consideration for open surgical repair must be taken into account. We present the successful management of persistent urine leakage after laparoscopic cyst decortication with endoscopic retrograde fibrin glue injection and ureteral stent placement.

  10. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    Directory of Open Access Journals (Sweden)

    Yohei Kawatani

    2016-01-01

    Full Text Available Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN. This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8% developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P=0.017 and P=0.032, resp.. Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P=0.018, and 95% CI = 1.46–59.7. Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement.

  11. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  12. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report

    Directory of Open Access Journals (Sweden)

    Kumagai Hozumi

    2012-09-01

    Full Text Available Abstract Introduction Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient’s general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  13. Temporary metallic stent placement in the treatment of refractory benign esophageal strictures: results and factors associated with outcome in 55 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Kim, Kyung Rae; Shin, Ji Hoon; Lim, Jin-Oh [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Song, Ho-Young [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea)]|[University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Seoul (Korea); Choi, Eugene K. [Weill Medical College of Cornell University, New York, NY (United States)

    2009-02-15

    The purpose of this study was to evaluate the effectiveness of temporary metallic stenting in 55 patients with treatment-resistant benign esophageal strictures and to identify factors associated with clinical outcomes. Under fluoroscopic guidance, covered retrievable stents were placed in 55 patients with benign esophageal strictures and were removed with retrieval hook 1 week to 6 months after placement. Stent placement was successful in all patients, and the mean dysphagia score was reduced from 2.8 to 1.3 (p<0.001). The most common complications were tissue hyperproliferation (31%), severe pain (24%), and stent migration (25%). During follow-up (mean: 38 months), recurrence of the stricture necessitating balloon dilation was seen in 38 (69%) of 55 patients. Maintained patency rates after temporary stenting at 1, 3, and 6 months and 1, 2, and 4 years were 58%, 43%, 38%, 33%, 26%, and 21%, respectively. In multivariate analysis, length (p=0.003) of the stricture was the only significant factor associated with maintained patency after temporary stenting. In conclusion, temporary metallic stenting for refractory benign esophageal strictures may be effective during the period of stent placement, but is disadvantaged by the high recurrence rates after stent removal, particularly in patients with a long length of stricture (>7cm). (orig.)

  14. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair

    OpenAIRE

    Zhu, Kai; Lai, Hao; Guo, Changfa; Li, Jun; Wang, Chunsheng

    2014-01-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report...

  15. Short-Term Biliary Stent Placement Contributing Common Bile Duct Stone Disappearance with Preservation of Duodenal Papilla Function

    Directory of Open Access Journals (Sweden)

    Tatsuki Ueda

    2016-01-01

    Full Text Available Aims. To investigate the effect of biliary stent placement without endoscopic sphincterotomy (EST on common bile duct stones (CBDS disappearance and the contribution of preserving the duodenal papilla function to reduce recurrence of CBDS. Methods. Sixty-six patients admitted for acute obstructive cholangitis due to CBDS who underwent biliary stent placement without EST for 2 years from March 2011 were evaluated retrospectively. The second endoscopic retrograde cholangiopancreatography (ERCP was performed for treatment of CBDS 3 to 4 months after the first ERCP. We estimated the rate of stone disappearance at the time of second ERCP. Results. CBDS disappearance was observed in 32 (48.5% of 66 patients. The diameter of the bile ducts and the diameter of CBDS in patients with CBDS disappearance were significantly smaller than in those with CBDS requiring extraction (p=0.007 and p<0.001, resp.. Stone disappearance was evident when the diameter of bile ducts and that of CBDS were <10 and 7 mm, respectively (p=0.002. Conclusions. Short-term stent placement without EST eliminates CBDS while preserving duodenal papilla function and may be suitable for treating CBDS in patients with nondilated bile ducts and small CBDS.

  16. Percutaneous unilateral biliary metallic stent placement in patients with malignant obstruction of the biliary hila and contralateral portal vein steno-occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Son, Rak Chae; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi Young [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents.

  17. Transurethral resection of fibrotic scar tissue combined with temporary urethral stent placement for patients with in anterior urethral stricture

    Directory of Open Access Journals (Sweden)

    Cheol Yong Yoon

    2014-08-01

    Full Text Available Introduction Fibrotic scar formation is a main cause of recurrent urethral stricture after initial management with direct vision internal urethrotomy (DVIU. In the present study, we devised a new technique of combined the transurethral resection of fibrotic scar tissue and temporary urethral stenting, using a thermo-expandable urethral stent (MemokathTM 044TW in patients with anterior urethral stricture. Materials and Methods As a first step, multiple incisions were made around stricture site with cold-cutting knife and Collins knife electrode to release a stricture band. Fibrotic tissue was then resected with a 13Fr pediatric resectoscope before deployment of a MemokathTM 044TW stent (40 – 60mm on a pre-mounted sheath using 0° cystoscopy. Stents were removed within 12 months after initial placement. Results We performed this technique on 11 consecutive patients with initial (n = 4 and recurrent (n = 7 anterior urethral stricture (April 2009 – February 2013. At 18.9 months of mean follow-up (12-34 months, mean Qmax (7.8±3.9ml/sec vs 16.8 ± 4.8ml/sec, p < 0.001, IPSS (20.7 vs 12.5, p = 0.001 , and QoL score (4.7 vs 2.2, p < 0.001 were significantly improved. There were no significant procedure-related complications except two cases of tissue ingrowth at the edge of stent, which were amenable by transurethral resection. In 7 patients, an average 1.4 times (1-5 times of palliative urethral dilatation was carried out and no patients underwent open surgical urethroplasty during the follow-up period. Conclusion Combined transurethral resection and temporary urethral stenting is a effective therapeutic option for anterior urethral stricture. Further investigations to determine the long-term effects, and safety profile of this new technique are warranted.

  18. The risk of post-ERCP pancreatitis and the protective effect of rectal indomethacin in cases of attempted but unsuccessful prophylactic pancreatic stent placement.

    Science.gov (United States)

    Choksi, Neel S; Fogel, Evan L; Cote, Gregory A; Romagnuolo, Joseph; Elta, Grace H; Scheiman, James M; Chak, Amitabh; Mosler, Patrick; Higgins, Peter D R; Korsnes, Sheryl J; Schmidt, Suzette E; Sherman, Stuart; Lehman, Glen A; Elmunzer, B Joseph

    2015-01-01

    It is believed, based on limited observational data, that an unsuccessful attempt to place a prophylactic pancreatic stent substantially increases the risk of post-ERCP pancreatitis (PEP). To better understand the risk of PEP in patients with failed pancreatic stent placement (FPS) and the impact of rectal indomethacin on this risk. Secondary analysis of randomized, controlled trial data. University of Michigan and Indiana University. A total of 577 clinical trial participants at elevated risk for PEP. Pancreatic stent placement. Within the placebo group, we compared PEP rates in patients with FPS, patients who underwent successful stent placement, and in those without a stent attempt. We also performed a regression analysis evaluating the association between FPS and PEP. To define the protective effect of indomethacin, we repeated these analyses in the indomethacin group and in the full study cohort. The incidence of PEP among patients in the placebo group who experienced FPS was 34.7%, significantly exceeding rates in patients who underwent successful stent placement (16.4%) and in those without a stent attempt (12.1%). After we adjusted for known PEP risk factors, FPS was found to be independently associated with PEP. Among the indomethacin group and in the full cohort, FPS was not associated with a higher risk of PEP. Low event rate, FPS not prospectively captured. FPS appears to confer an increased risk of PEP, which is attenuated by rectal indomethacin administration. These findings highlight the importance of adequate training and proficiency before endoscopists attempt pancreatic stent placement and the routine use of rectal indomethacin in high-risk ERCP cases. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  19. Dutch iliac stent trial : Long-term results in patients randomized for primary or selective stent placement

    NARCIS (Netherlands)

    Klein, W.M.; van der Graaf, Y.; Seegers, J.; Spithoven, J.H.; Buskens, E.; van Baal, J.G.; Buth, J.; Moll, F.L.; Overtoom, T.T.C.; van Sambeek, M.R.H.M.; Mali, W.P.T.M.

    2006-01-01

    Purpose: To determine long-term results of the prospective Dutch Iliac Stent Trial. Materials and Methods: The study protocol was approved by local institutional review boards. All patients gave written informed consent. Two hundred seventy-nine patients (201 men, 78 women; mean age, 58 years) with

  20. Y-Shaped Bilateral Self-Expandable Metallic Stent Placement for Malignant Hilar Biliary Obstruction: Data from a Referral Center for Palliative Care

    Directory of Open Access Journals (Sweden)

    R. Di Mitri

    2014-01-01

    Full Text Available Background and Aim. Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. Methods. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Results. Twenty patients (9 males were treated (mean age 64.2 ± 15.3 years. The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%, IIIa in 1 (5%, and IV in 14 (70%. The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL. One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months, 13 of the 20 patients (65% had died. Conclusions. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  1. Obstructing fungal cholangitis complicating metal biliary stent placement in pancreatic cancer

    Institute of Scientific and Technical Information of China (English)

    Brian; Story; Michael; Gluck

    2010-01-01

    Biliary obstructions can lead to infections of the biliary system, particularly in patients with occluded biliary stents. Fungal organisms are frequently found in bili-ary aspirates of patients who have been on antibiotics and have stents; however, fungal masses, or "balls", that fully obstruct the biliary system are uncommon and exceedingly diff icult to eradicate. We present 4 cases of obstructing fungal cholangitis in patients who had metal biliary stents placed for pancreatic malignancies, and subsequen...

  2. Clinical analysis of biliary stent placement combined with gamma-knife for the treatment of complex hilar cholangiocarcinoma

    Directory of Open Access Journals (Sweden)

    Zhi-qiang FENG

    2011-05-01

    Full Text Available Objective To evaluate the therapeutic effect of biliary stent placement combined with gamma-knife for the treatment of complex hilar cholangiocarcinoma.Methods Five patients with type IV hilar cholangiocarcinoma,according to Bismuth classification,combined with stenosis of distant common bile duct were treated with biliary stent placement and gamma-knife.The left intrahepatic bile duct was catheterized under the guidance of ultrasound,followed by catheterization of right intrahepatic bile duct aided by percutaneous transhepatic cholangiography for drainage(PTCD.Three biliary stents were inserted to relieve obstruction.Patients then underwent gamma-knife treatment after subsidence of jaundice,and bilirubin,followed by determination of transaminase and observation of the condition of the tumor.Results Total bilrubin,direct bilrubin and alanine transaminase of patients were 289.38±101.43μmol/L,180.42±72.50μmol/L and 148.80±82.65 U/L respectively before PTCD,and 94.2±20.43μmol/L,62.37±30.41μmol/L and 109.27±45.52 U/L,respectively,7 days after PTCD,and they declined to 27.20±14.60μmol/L,20.58±9.33μmol/L and 59.80±35.18 U/L,respectively,one month after PTCD.Five patients survived for 10,13,14,17 and 24 months,respectively.The median survival time was 15 months.Conclusion The combination of insertion of metallic stents and gamma-knife therapy is a safe and effective treatment for complex hilar cholangiocarcinoma,and this therapeutic strategy may improve survival rate and control the rate of grouth of carcinoma.

  3. Prophylactic placement of a covered nitinol stent to prevent carotid blowout in a patient with supraclavicular lymph node metastasis from esophageal cancer.

    Science.gov (United States)

    Fujita, Takeshi; Ito, Katsuyoshi; Tanabe, Masahiro; Matsunaga, Naofumi

    2015-01-01

    Enlargement of primary tumor and metastatic lymph nodes in patients with head and neck cancer can be progressive and invade the surrounding vessels despite intensive treatment. Carotid blowout (CBS) tends to occur in these patients, and prompt treatment is required. Surgical management of carotid blowout is technically troublesome because exploration and repair of the previously irradiated or tumor-invaded field are difficult. Endovascular therapy with stent deployment is a good alternative to surgery. Even with such interventional procedures as stent grafting, it is sometimes difficult to obtain favorable outcomes in end-stage patients with poor general conditions. The prophylactic placement of a covered nitinol stent was performed to prevent carotid blowout in a patient with supraclavicular lymph node metastasis from esophageal cancer, and fatal bleeding due to carotid blowout was avoided. The usefulness of the prophylactic placement of a covered nitinol stent for preventing carotid blowout in an end-stage patient is presented.

  4. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair

    Science.gov (United States)

    Zhu, Kai; Guo, Changfa; Li, Jun

    2014-01-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report suggests that the palliative strategy may be an option for RAD in some specific situation. PMID:25590002

  5. Palliative stent graft placement combined with subsequent open surgery for retrograde ascending dissection intra-thoracic endovascular aortic repair.

    Science.gov (United States)

    Zhu, Kai; Lai, Hao; Guo, Changfa; Li, Jun; Wang, Chunsheng

    2014-12-01

    Thoracic endovascular aortic repair (TEVAR) is an effective strategy for type B dissection. Retrograde ascending dissection (RAD) intra-TEVAR is a rare complication on clinic. In this case, a 48-year-old Chinese man with Stanford type B aortic dissection suffered acute RAD during the TEVAR. And palliative stent grafts placement was performed in a local hospital, which earned the time for transfer and subsequent total arch replacement surgery in Zhongshan Hospital Fudan University. This report suggests that the palliative strategy may be an option for RAD in some specific situation.

  6. Placement of hemoparin-coated stents in the iliac arteries: Early experience and midterm results in 28 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kalmar, Peter I., E-mail: peter.kalmar@medunigraz.at; Portugaller, Rupert H., E-mail: rupert.portugaller@medunigraz.at; Schedlbauer, Peter, E-mail: peter.schedlbauer@klinikum-graz.at; Bohlsen, Dennis, E-mail: dennis.bohlsen@medunigraz.at; Deutschmann, Hannes A., E-mail: hannes.deutschmann@medunigraz.at

    2014-07-15

    Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents.

  7. Percutaneous Placement of Permanent Metallic Stents in the Cystic Duct to Treat Obstructive Cholecystitis.

    Science.gov (United States)

    Brown, Nicholas I; Jhamb, Ashu; Brooks, Duncan M; Little, Andrew F

    2015-12-01

    This report presents a series of five patients unsuitable for surgery who had nonretrievable self-expanding metallic stents deployed along the cystic duct as treatment for benign and malignant causes of gallbladder obstruction. Techniques are described for draining cholecystitis, removing gallstones, bypassing gallbladder obstructions, and inserting metallic stents across the cystic duct to restore permanent antegrade gallbladder drainage in acute and chronic cholecystitis. Symptoms resolved in all cases, and stents remained patent for as long as 22 months. This procedure may be an effective alternative to cholecystectomy or long-term gallbladder drainage for patients in inoperable condition.

  8. A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

    Directory of Open Access Journals (Sweden)

    Canena Jorge Manuel

    2012-06-01

    Full Text Available Abstract Background Refractory benign esophageal strictures (RBESs have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs, biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs, for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10, biodegradable stents (n = 10 or FCSEMSs (12 weeks, n = 10. Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60% in the SEPS group, 2 (20% in the biodegradable group and 3 (30% in the FCSEMS group (P = 0.16. A total of 8/30 patients (26.6% were dysphagia-free after the end of follow-up: 1 (10% in the SEPS group, 3 (30% in the biodegradable group and 4 (40% in the FCSEMS group (P = 0.27. More reinterventions were required in the SEPS group (n = 24 than in the biodegradable group (n = 13 or the FCSEMS group (n = 13 (P = 0.24. Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011. Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence.

  9. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Qining, E-mail: cqmufqn@163.com; Meng, Xiyun, E-mail: 383274177@qq.com; Li, Fenghe, E-mail: lfh-cqmu@gmail.com; Wang, Xuehu, E-mail: 184037696@qq.co; Cheng, Jun, E-mail: cqdcj@163.com; Huang, Wen, E-mail: dhuangwen@hotmail.com; Ren, Wei, E-mail: renwei9771@yahoo.com.cn; Zhao, Yu, E-mail: zhaoyu-cqmu@126.com [The First Affiliated Hospital of Chongqing Medical University, Department of Vascular Surgery (China)

    2015-06-15

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment.

  10. Combined stent placement and high dose PGE1 drip infusion for chronic occlusion of the superficial femoral artery as a modality to salvage chronic critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, Ichiro [Department of Radiology, Miyakonojo Medical Association Hospital, 5822-3 Oiwadacho, Miyakonojo 885-0062 (Japan)], E-mail: iku-i@fk.enjoy.ne.jp; Hirai, Toshinori [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University (Japan); Ishii, Akihiko [Department of Radiology, Miyakonojo Medical Association Hospital, 5822-3 Oiwadacho, Miyakonojo 885-0062 (Japan); Yamashita, Yasuyuki [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University (Japan)

    2008-04-15

    Purpose: To assess the initial effect, short-term patency, and limb salvage rates of combined stent placement and high-dose prostaglandin E-1 (PGE1) drip infusion for chronic occlusion of the superficial femoral artery (SFA). Materials and methods: A total of 15 arteriosclerotic occlusive lesions of the SFA were treated in 11 consecutive patients (mean age: 78.4 years old). All cases were of category 4 or 5, based on the criteria of the Society of Vascular Surgery and Intermittent Society for Cardiovascular Surgery (SVC/ISCVS). In all cases a self-expandable stainless steel stent was implanted. PGE1 treatment was started 3-5 days before stent placement and continued for 7-10 days after the intervention. The technical success, limb salvage outcomes, patency rates, and complications were examined. Results: In all cases, the technical success rate of the procedure was 100%. After stent implantation, the clinical status of all cases was improved by at least +2, and major amputation was not required in any cases. The 12-month primary, secondary patency rates, and limb salvage rate were 57%, 100%, and 100%, respectively. Conclusion: Combined stent placement and high-dose PGE1 drip infusion is a treatment of choice for salvaging the lower limb of a patient with chronic critical ischemia.

  11. Radiological image-guided placement of covered Niti-S stent for palliation of dysphagia in patients with cervical esophageal cancer.

    Science.gov (United States)

    Fujita, Takeshi; Tanabe, Masahiro; Shimizu, Kensaku; Iida, Etsushi; Matsunaga, Naofumi

    2013-06-01

    The aim of this study was to evaluate the clinical effectiveness of covered Niti-S stent placement under multidetector CT and fluoroscopy guidance for the palliation of dysphagia in patients with cervical esophageal cancer. Under radiological imaging guidance using axial and sagittal CT scans, and fluoroscopy, Niti-S esophageal stents were placed in ten consecutive patients with complete obstruction caused by cervical esophageal cancer (9 men and 1 woman; age range = 54-79 years; mean age = 68.1 years) between February 2010 and December 2011. The procedure time and technical success rate were evaluated. Swallowing improvement was assessed by the following items: ability to eat and/or swallow (graded as follows: 3 = ability to eat normal diet, 2 = ability to eat semisolids, 1 = ability to swallow liquids, 0 = complete obstruction). Procedural and post-procedural complications were also evaluated. Survival (mean ± SD) was examined. The mean (±SD) procedure time was 40 ± 19 min (range = 21-69 min). Stent placement was technically successful in all patients; inadequate stent deployment did not occur in any case. Ability to eat and/or swallow was improved and scored 2.4 (score 3 in 5 cases, score 2 in 4 cases, score 1 in 1 case, and score 0 in no case) after stent placement. No major or post-procedural complications were encountered. The mean survival time was 131 ± 77 days (range = 31-259 days). Niti-S stents appeared to be a safe and effective device for the palliation of dysphagia caused by advanced cervical esophageal cancer. Multidetector CT and fluoroscopy image guidance helped the operators accurately place the stents in the cervical esophagus.

  12. Anesthetic management of a large mediastinal mass for tracheal stent placement

    Directory of Open Access Journals (Sweden)

    Suman Rajagopalan

    2016-04-01

    Full Text Available ABSTRACT The anesthetic management of patients with large mediastinal masses can be complicated due to the pressure effects of the mass on the airway or major vessels. We present the successful anesthetic management of a 64-year-old female with a large mediastinal mass that encroached on the great vessels and compressed the trachea. A tracheal stent was placed to relieve the tracheal compression under general anesthesia. Spontaneous ventilation was maintained during the perioperative period with the use of a classic laryngeal mask airway. We discuss the utility of laryngeal mask airway for anesthetic management of tracheal stenting in patients with mediastinal masses.

  13. Evaluation of hemodynamics changes during interventional stent placement using Doppler optical coherence tomography

    Science.gov (United States)

    Vuong, Barry; Genis, Helen; Wong, Ronnie; Ramjist, Joel; Jivraj, Jamil; Farooq, Hamza; Sun, Cuiru; Yang, Victor X. D.

    2015-03-01

    Carotid atherosclerosis is a critical medical concern that can lead to ischemic stroke. Local hemodynamic patterns have also been associated with the development of atherosclerosis, particularly in regions with disturbed flow patterns such as bifurcations. Traditionally, this disease was treated using carotid endarterectomy, however recently there is an increasing trend of carotid artery stenting due to its minimally invasive nature. It is well known that this interventional technique creates changes in vasculature geometry and hemodynamic patterns due to the interaction of stent struts with arterial lumen, and is associated with complications such as distal emboli and restenosis. Currently, there is no standard imaging technique to evaluate regional hemodynamic patterns found in stented vessels. Doppler optical coherence tomography (DOCT) provides an opportunity to identify in vivo hemodynamic changes in vasculature using high-resolution imaging. In this study, blood flow profiles were examined at the bifurcation junction in the internal carotid artery (ICA) in a porcine model following stent deployment. Doppler imaging was further conducted using pulsatile flow in a phantom model, and then compared to computational fluid dynamics (CFD) simulation of a virtual bifurcation to assist with the interpretation of emphin vivo results.

  14. Spiral-CT angiography after intraarterial iliac stent placement; Spiral-CT-Angiographie nach arterieller iliakaler Stentapplikation

    Energy Technology Data Exchange (ETDEWEB)

    Freund, M. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik; Palmie, S. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik; Wesner, F. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik; Heller, M. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik

    1995-10-01

    In a prospective study 32 patients underwent CT-A after stent placement in the iliac arteries. The vascular morphology was analyzed regarding neointimal hyperplasia and calcification pattern. The results were compared with those of clinical findings (walking distance), Doppler ultrasound (ankle-brachial index) and DSA. All 47 stents were visible and patent (100%). One misplacement was identified. A good correlation was found between an improved ankle-brachial index and CT-A (88.5%) and extension of the walking distance and CT-A (92.3%). Concerning location, number and grade of stenoses the results between CT-A and DSA matched in 42.1%. An exact mapping of calcified plaques was possible in all cases. (orig./MG) [Deutsch] Nach perkutaner transluminaler Angioplastie (PTA) und Stenteinlage wurden 32 Patienten prospektiv mittels CT-A untersucht. Es erfolgte eine Analyse der Gefaessmorphologie hinsichtlich neointimaler Hyperplasien und Verkalkungsmuster. Weiterhin wurden die Ergebnisse mit denen der intraarteriellen digitalen Subtraktionsangiographie (i.a. DSA), dem klinischen Befund (Gehstrecke) und der Doppler-Ultraschalluntersuchung (Arm-Knoechel-Index/AKI) verglichen. Alle 47 Stents konnten in der CT-A exakt lokalisiert und als offen identifiziert werden (100%). Eine Stentfehllage wurde diagnostiziert. Der Nachweis neointimaler Hyperplasie gelang aufgrund von Metallartefakten im Stentniveau nicht. Verkalkungen waren in allen Faellen nachweisbar. Eine Uebereinstimmung zwischen DSA und CT-A hinsichtlich des Schweregrades, der Anzahl und Lokalisation von Stenosen fand sich nur in 42,1%. In 88,5% der Faelle bestand eine Uebereinstimmung zwischen CT-morphologischem Befund und verbessertem AKI, in 92,3% mit verlaengerter Gehstrecke. (orig./MG)

  15. Early local intracoronary platelet activation after drug-eluting stent placement

    Institute of Scientific and Technical Information of China (English)

    Ailiman Mahemuti; Nicolas Meneveau; Marie-France Seronde; Francois Schiele; Mariette Mercier; Evelyne Racadot; Jean-Pierre Bassand

    2007-01-01

    Background Early local platelet activation after coronary intervention identifies patients at increased risk of acute stent thrombosis (AST). However, early changes in platelet activation in coronary circulation following drug-eluting stent (DES) implantation have never been reported.Methods In a prospective study of 26 consecutive elective stable angina patients, platelet activation was analyzed by measuring soluble glycoprotein V (sGPV) and P-selectin (CD62P) before and after implantation of either DES or bare metal stent (BMS). All patients were pretreated with clopidogrel (300 mg loading dose) and aspirin (75 mg orally) the day before the procedure. Blood samples were drawn from the coronary ostium and 10 - 20 mm distal to the lesion site.Results Consistent with the lower baseline clinical risk, the levels of CD62P and sGPV were within normal reference range, both in the coronary ostium and distal to the lesion before percutaneous coronary intervention (PCl) procedure.The levels of CD62P and sGPV did not change significantly (CD62P: (31.1 ± 9.86) ng/ml vs (29.5 ± 9.02) ng/ml, P=0.319and sGPV: (52.4 ± 13.5) ng/ml vs (51.8 ± 11.7) ng/ml, P=0.674, respectively) after stent implantation when compared with baseline. Changes in these platelet activation markers did not differ between stent types.Conclusions Intracoronary local platelet activation does not occur in stable angina patients before and immediately following DES implantation when dual anti-platelet is administered.

  16. Role of self expandable stents in management of colorectalcancers

    Institute of Scientific and Technical Information of China (English)

    2016-01-01

    Acute malignant colorectal obstruction is a complicationof colorectal cancer that can occur in 7%-29% of patients. Self-expanding metallic stent placement formalignant colorectal obstruction has gained popularity asa safe and effective procedure for relieving obstruction.This technique can be used in the palliation of malignantcolorectal obstruction, as a bridge to elective surgery forresectable colorectal cancers, palliation of extracolonicmalignant obstruction, and for nonmalignant etiologiessuch as anastomotic strictures, Crohn's disease, radiationtherapy, and diverticular diseases. Self-expandingmetallic stent has its own advantages and disadvantagesover the surgery in these indications. During the insertionof the self-expanding metallic stent, and in the followup,short term and long term morbidities should be keptin mind. The most important complications of the stentsare perforation, stent obstruction, stent migration, andbleeding. Additionally, given the high risk of perforation,if a patient is treated or being consideredfortreatmentwithantiangiogenic agents such as bevacizumab, it isnot recommended to use self-expanding metallic stentas a palliative treatment for obstruction. Therefore, thereis a need for careful clinical evaluation for each patientwho is a candidate for this procedure. The purpose ofthis review was to evaluate self-expanding metallic stentin the management of the obstruction of the colon dueto the colorectal and extracolonic obstruction.

  17. Treatment of internal carotid artery dissections with endovascular stent placement: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-03-01

    Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  18. Retrograde Stent Placement for Coil Embolization of a Wide-Necked Posterior Inferior Cerebellar Artery Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee; Chun, Young IL; Choi, Jin Woo; Cho, Joon; Moon, Won Jin [University College of Medicine, Seoul (Korea, Republic of); Solander, Sten [University of North Carolina School of Medicine, Chapel Hill (United States)

    2012-07-15

    Wide-necked aneurysms of the posterior inferior cerebellar artery (PICA) are infrequently encountered in cerebrovascular practice, and endovascular treatment is difficult or impossible even with the use of several neck remodeling techniques. We present the case of a patient with a wide-necked aneurysm of the PICA, which was treated by the retrograde stenting through the contralateral vertebral artery and vertebrobasilar junction with antegrade coil embolization.

  19. Impotence due to external Iliac steal syndrome: Treatment with percutaneous transluminal angioplasty and stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Gur, Serkan [Sifa University, Dept. of Radiology, Izmir (Turkmenistan); Oguzkurt, Levent; Kaya, Bilal; Tekbas, Guven; Ozkan, Ugur [Baskent University, Faculty of Medicine, Dept. of Radiology, Adana (Turkmenistan)

    2013-01-15

    We report a case of erectile dysfunction caused by external iliac artery occlusion, associated with pelvic steal syndrome; bilateral internal iliac arteries were patent. The patient stated that he had experienced erectile dysfunction at similar times along with claudication, but he did not mention it before angiography. He expressed that the erectile dysfunction did not last long and that he felt completely okay after the interventional procedure, in addition to his claudication. Successful treatment of the occlusion, by percutaneous transluminal angioplasty and stent implantation, helped resolve erectile dysfunction completely and treat the steal syndrome.

  20. Placement of Endovascular Stent across the Branching Arteries: Long-term Serial Evaluation of Stent-tissue Responses Overlying the Arterial Orifices in an Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Il; Chung, Jin Wook, E-mail: chungjw@snu.ac.kr [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Kim, Hyun Beom [National Cancer Center of Korea, Department of Radiology and Center for Liver Cancer, Research Institute and Hospital (Korea, Republic of); Park, Jae Hyung [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Seo, Jeong Wook [Seoul National University College of Medicine, Department of Pathology (Korea, Republic of); Kim, Hyo-Cheol; Jae, Hwan Jun; Lee, Whal [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of)

    2012-10-15

    PurposeThis study was designed to investigate the effects of stenting across the branching arteries on the patency and stent-tissue responses over the branching arterial orifices. Methods: Thirteen dogs were observed after placing aortic stents across the celiac arteries (CA), superior mesenteric arteries (SMA), and renal arteries (RA). The animals were grouped according to stent types: large-cell group (n = 6) and small-cell group (n = 7). Angiography was performed to evaluate the branching artery patency at 2, 6, and 12 months after stent insertion, and the stent-tissue responses covering the orifices were evaluated on histopathologic examination. Results: All branching arteries were patent on follow-up angiography; however, three patterns of stent-tissue responses over the orifices were observed: neointimal layering, bridging septa, and papillary hyperplasia. Although neointimal layering and bridging septa were evenly observed, severe papillary hyperplasia was more frequent at SMA and CA than RA. Four RA showed less than 50% ostial patency, and localized infarct was observed in six kidneys (24%). The ostial patency tended to decrease with small-cell stent during the follow-up period. Conclusions: Various stent-tissue responses over the branching artery orifices are induced by the aortic stent covering the branching arteries and may not be easily detected by conventional angiography. Subclinical renal infarct also may occur despite patent renal angiography.

  1. Outcomes of Percutaneous Management of Anastomotic Ureteral Strictures in Renal Transplantation: Chronic Nephroureteral Stent Placement with and without Balloon Dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Uflacker, A., E-mail: andreuflacker@gmail.com; Sheeran, D., E-mail: dsheeran9@gmail.com; Khaja, M., E-mail: mkhaja@mac.com [University of Virginia/Interventional Radiology (United States); Patrie, J., E-mail: jp4h@virginia.edu [UVA Health System/Radiology (United States); Elias, G., E-mail: gae2y@virginia.edu [VCU Medical Center/Radiology (United States); Saad, W., E-mail: wspikes@yahoo.com [University of Michigan Health System (United States)

    2015-06-15

    PurposeThis study was designed o evaluate outcomes of percutaneous management of anastomotic ureteral strictures in renal transplants using nephroureteral stents with or without balloon dilatation.MethodsA retrospective audit of 1,029 consecutive renal transplants was performed. Anastomotic ureteral strictures were divided into two groups: nephroureteral stent only (NUS) and NUS+PTA (nephroureteral stent plus percutaneous transluminal angioplasty), with each cohort subdivided into early versus late presentation (obstructive uropathy occurring <90 day or >90 days from transplant, respectively). Overall and 6-month technical success were defined as removal of NUS any time with <30 % residual stenosis (any time lapse less or more than 6 months) and at >6 months, respectively. Patency was evaluated from NUS removal to last follow-up for both groups and compared.ResultsSixty-seven transplant patients with 70 ureteric anastomotic strictures (6.8 %, n = 70/1,029) underwent 72 percutaneous treatments. 34 % were late (>90 days, n = 24/70), and 66 % were early (<90 days, n = 46/70). Overall technical success was 82 % (n = 59/72) and 6-month success was 58 % (n = 42/72). Major and minor complications were 2.8 % (n = 2/72), and 12.5 % (n = 9/72). NUS+PTA did not improve graft survival (p = 0.354) or patency (p = 0.9) compared with NUS alone. There was no difference in graft survival between treated and nontreated groups (p = 0.74).ConclusionsThere is no advantage to PTA in addition to placement of NUS, although PTA did not negatively impact graft survival or long-term patency and both interventions were safe and effective. Neither the late or early groups benefited from PTA in addition to NUS. Earlier obstructions showed greater improvement in serum creatinine than later obstructions.

  2. The endoscopic trans-fourth ventricle aqueductoplasty and stent placement for the treatment of trapped fourth ventricle: Long-term results in a series of 18 consecutive patients

    Directory of Open Access Journals (Sweden)

    Pasquale Gallo

    2012-01-01

    Full Text Available Background: Different surgical approaches have been described in the past to treat a trapped fourth ventricle (TFV but, unfortunately, these techniques showed a high rate of dysfunction and complications. During the last 10 years the development of neuroendoscopy has dramatically changed the outcome of these patients. Materials and Methods: We conducted a retrospective evaluation of the safety, effectiveness, and long-term outcome of endoscopic aqueductoplasty and stent placement, performed in 18 consecutive patients with symptomatic TFV through a trans-fourth ventricle approach between 1994 and 2010. Thirteen patients underwent endoscopic aqueductoplasty and stent placement and 5 patients underwent aqueductoplasty alone using a tailored suboccipital approach through the foramen of Magendie in prone or sitting position. Results: The mean age of the patients at the time of surgery was 15.2 years. All patients but 3 had a supratentorial ventriculoperitoneal shunt. Fifteen patients presented with slit supratentorial ventricles. At a mean followup of 90.8 months all patients experienced a stable clinical improvement. Only two complications were observed: A transient diplopia due to dysconjugate eye movements in one patient and a transient trochlear palsy in another one. Conclusions: Our experience and the literature review suggest that endoscopic trans-fourth ventricle aqueductoplasty and stent placement is a minimally invasive, safe, and effective technique for the treatment of TFV and should be strongly recommended, especially in patients with supratentorial slit ventricles.

  3. Dobutamine Stress Cardiovascular Magnetic Resonance Imaging in Patients after Invasive Coronary Revascularization with Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Heilmaier, C.; Meier, F.; Forsting, M.; Schlosser, T.W. (Dept. of Diagnostic and Interventional Radiology and Neuroradiology, Univ. Hospital Essen, Essen (Germany)). e-mail: christina.heilmaier@uni-due.de; Bruder, O.; Jochims, M.; Sabin, G.V. (Dept. of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany)); Barkhausen, J. (Dept. of Radiology and Nuclear Medicine, Univ. Hospital Schleswig-Holstein, Campus Luebeck, Luebeck (Germany))

    2009-12-15

    Background: High-dose dobutamine stress magnetic resonance (DSMR) is a well-established imaging technique for the detection of coronary artery disease (CAD). Purpose: To investigate the value of DSMR for the detection of in-stent restenoses (ISR) in patients with prior coronary stenting, using invasive coronary angiography (ICA) as the standard of reference. Material and Methods: 50 patients with 74 stents and without wall motion abnormalities at rest were examined on a 1.5T MR scanner and underwent ICA for clinical reasons within 14 days after DSMR examination. A dobutamine/atropine stress protocol was employed until age-predicted heart rate was achieved, and imaging was performed in at least three long- and three short-axis views using a segmented steady-state free precession sequence (repetition/echo time [TR/TE] 3/1.5 ms, flip angle 60 deg). All examinations were read by an experienced cardiologist and radiologist in consensus, with myocardial ischemia being defined as a new stress-induced wall motion abnormality in at least one myocardial segment. Statistical analysis was performed on a per-vessel (left circumflex artery [LCX], left anterior descending artery [LAD], and right coronary artery [RCA]) basis and with regard to the number of affected vessels (one-, two- or three-vessel disease). Results: ICA yielded seven ISR, of which one was missed by DSMR (sensitivity 86%, 95% confidence interval [CI] 0.42-0.99). Sixty-seven coronary arteries showed no ISR in ICA; however, due to new wall motion abnormalities, seven ISR were suspected in DSMR (2xRCA, 3xLCX, and 2xLAD; sensitivity 86%, specificity 90%, positive predictive value 46%, negative predictive value 98%, and diagnostic accuracy 89%). The per-vessel analysis of the three main coronary arteries revealed highest sensitivity (100%), specificity (93%), and diagnostic accuracy (94%) for the LAD. Conclusion: High-dose DSMR is an accurate, noninvasive technique for the detection of ISR and reliably allows

  4. Placement of removable metal biliary stent in post-orthotopic liver transplantation anastomotic stricture

    Institute of Scientific and Technical Information of China (English)

    Hoi-Poh; Tee; Martin; W; James; Arthur; J; Kaffes

    2010-01-01

    Postoperative biliary strictures are the most common cause of benign biliary stricture in Western countries, secondary to either operative injury or bile duct anastomotic stricture following orthotopic liver transplantation(OLT).Surgery or endoscopic interventions are the mainstay of treatment for benign biliary strictures.We aim to report the outcome of 2 patients with refractory anastomotic biliary stricture post-OLT,who had successful temporary placement of a prototype removable covered self-expandable m...

  5. Changes in coronary bifurcations after stent placement in the main vessel and balloon opening of stent cells:theory and practical verification on a bench-test model

    Institute of Scientific and Technical Information of China (English)

    Dobrin Vassilev; Robert Gil

    2008-01-01

    Objective To describe changes that occur in stent morphology and structure after its implantation in coronary bifurcation.Side branch (SB) compromise after stenting of main vessel in coronary bifurcation is a major intraprocedural problem and for the long term,as a place of restenosis.Methods We created an elastic wall model (parent vessel diameter 3.5mm,daughter branches 3.5mm and 2.75mm)with 30,45 and 60 degree distal angulation between branches.After stent implantation,struts to the side branch were opened with 2.0mm and consequently 3.0mm diameter balloons.Subsequent balloon redilatations and kissing balloon inflations (KBI) were performed.All stages of the procedure were photographed with magnification up to 100 times.Results We found that the leading mechanism for side branch compromise was carina displacement,and discovered theoretical description for expected ostial stenosis severity.Based on our model we found that displacement of bifurcation flow divider cause SB stenosis with almost perfect coincidence with our theoretical predictions.Opening of stent cells through the proximal and distal stent struts always increased interslrut distance,but never achieved good apposition to the wall.Balloon diameter increase didn't give proportional enlargement in stent cell diameters.KBI leads to some small better stent positioning,correcting main vessel strut dislodgment from wall,but never gave full strut-wall contact.Distance between struts and wall was minimal only when the stent cell perfectly faced ostium of SB.This was also our observation that the shape of ostium of SB becomed eUiptically-bean shaped after stent implantation and generally kept that shape during consequent stages of experiment.Measured diameter and area stenosis were perfectly fitted and theoretically predicted from our concept Conclusion We have described stent-wall deformations in stent-balloon technique for treatment of coronary bifurcation demonstrating carina displacement as possibly main

  6. Lethal post-endoscopic retrograde cholangiopancreatography pancreatitis following fully covered metal stent placement in distal biliary obstruction due to unresectable cholangiocarcinoma.

    Science.gov (United States)

    Itoi, Takao; Tsuchiya, Takayoshi; Tanaka, Reina; Ikeuchi, Nobuhito; Sofuni, Atsushi

    2013-05-01

    Biliary self-expandable metallic stent (SEMS) is the preferred and first-line therapy for unresectable malignant biliary obstruction. To date, several reports have revealed the relatively high incidence of acute complications such as pancreatitis and cholecystitis due to mechanical stent compression. In the present case, we encountered fatal pancreatitis following fully covered metal stent placement. An 85-year-old man had middle bile duct strictures due to cholangiocarcinoma. A 10-mm diameter fully covered SEMS was placed across the papilla for biliary decompression. Laboratory data and physical evidence the following day revealed acute pancreatitis. Therefore, antibiotics and protein degeneration enzyme inhibitors were given. However, his condition did not improve. Two days after the procedure, we removed the stent and returned him to his original hospital. Serum amylase level decreased below 400 mg/dL 6 h after the procedure. However, the acute pancreatitis worsened. Although we treated the patient in the intensive care unit, he died 32 days after the second admission.

  7. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, Vimal, E-mail: drvimalmehta@yahoo.co.in; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay [G.B. Pant Institute of Postgraduate Medical Education and Research (India)

    2016-01-15

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory.

  8. The role of airway stent placement in the management of tracheobronchial stenosis caused by inoperable advanced lung cancer.

    Science.gov (United States)

    Furukawa, Kinya; Ishida, Junzo; Yamaguchi, Gaku; Usuda, Jitsuo; Tsutsui, Hidemitsu; Saito, Makoto; Konaka, Chimori; Kato, Harubumi

    2010-04-01

    To our knowledge there is no in-depth report on the benefits of airway stenting, which focuses specifically on patients with inoperable advanced lung cancer causing severe central airway obstruction. We evaluated the role of airway stenting as one aspect of the multidisciplinary management of advanced lung cancer. We performed airway stenting in 40 lung cancer patients, placing a total of 58 stents. Stenting was done as a final modality in 22 patients with terminal-stage lung cancer (group A). The other 18 patients received additional therapy after stenting (group B), 12 (66.7%) of whom were treatment-naïve on admission. The performance status (PS) and Hugh-Jones classification (H-J) scores improved in both groups after stenting: from 3.56 to 2.48 (P = 0.001) and 4.29 to 3.20 (P = 0.004) in group A, and from 3.15 to 1.25 (P Airway stenting followed by adjuvant therapy may improve the survival of treatment-naïve patients with severe symptomatic airway obstruction caused by advanced lung cancer.

  9. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren;

    2004-01-01

    condition. Three days after stent deployment, x-ray examinations revealed a small-bowel obstruction and emergency surgery was performed. Intraoperative findings demonstrated a segment of ileum fixated to the tumor in the small pelvis, resulting in the obstructive condition. Furthermore, a cecal perforation...... to this specific treatment. We conclude that although a patient is eligible for treatment with self-expanding metal stents, large-bowel obstruction can be too "old" for stent-decompression, causing ischemic perforation of the colon. Furthermore, we underline the need to focus on the possibility of obstructions...

  10. Two-year clinical outcomes after coronary drug-eluting stent placement in Chinese men and women: a multicenter, prospective registry study

    Directory of Open Access Journals (Sweden)

    Shrestha R

    2013-07-01

    Full Text Available Rajiv Shrestha,1 Sandeep Gami,1 Jing Xu,2 Du-Jiang Xie,2 Zhi-Zhong Liu,2 Tian Xu,1 Fei Ye,2 Shi-Qing Din,3 Xue-Song Qian,4 Song Yang,5 Yue-Qiang Liu,6 Feng Li,7 Ai-Ping Zhang,8 Shao-Liang Chen2 1Nanjing Medical University, Nanjing, 2Nanjing First Hospital, Nanjing Medical University, Nanjing, 3Huainan Xinhua Hospital, Huainan, 4Zhangjiagang People's Hospital, Zhangjiagang, 5Yixin People's Hospital, Yixin, 6Jintan People's Hospital, Jintan, 7Huainan Oriental General Hospital, Huainan, 8Huainan People's Hospital, Huainan, People's Republic of China Background: Previous studies have reported a discrepancy in baseline characteristics and outcomes after percutaneous coronary intervention between men and women. However, this finding has never been verified in the Chinese population. The present study analyzed two-year clinical outcomes after placement of coronary drug-eluting stents in Chinese men and women. Methods: From January 2005 to December 2010, a total of 3804 Chinese patients (2776 men, 1028 women who underwent drug-eluting stent implantation were studied prospectively. The primary endpoint was the composite major adverse cardiac event (MACE rate, including myocardial infarction, cardiac death, and target vessel revascularization at two years. Stent thrombosis served as the safety endpoint. Propensity score matching was used to compare the adjusted MACE rate between the two groups. Results: At two-year follow-up, unadjusted rates of myocardial infarction, non-ST segment elevation myocardial infarction, target vessel revascularization, and MACE were significantly different between men (6.84%, 4.6%, 13.1%, and 21.7%, respectively and women (3.8% [P = 0.001], 2.0% [P < 0.001] 10.3% [P = 0.025], and 16.3% [P < 0.001], respectively. After propensity score matching, there were no significant differences in composite MACE and individual endpoints at two years between the genders. Conclusion: Despite all the unfavorable risk factor clustering in

  11. Successful Self-Expandable Metallic Stent Placement for a Case of Distal Rectal Stenosis due to Gastric Cancer Metastasis

    Directory of Open Access Journals (Sweden)

    Takuya Okugawa

    2013-05-01

    Full Text Available A 47-year-old woman was diagnosed as having advanced gastric cancer with malignant ascites. Despite chemotherapy, recurrent peritoneal dissemination was seen 1.5 years after operation. A computed tomography scan revealed rectal stenosis due to Schnitzler's metastasis. When the distance from the distal end of the obstruction to the anal verge is less than 5 cm, stent replacement has been said to be contraindicated due to the development of anal pain and foreign body sensation. Although the distance from the distal end of the obstruction to the anal verge was 4 cm in this case, a WallFlex™ colonic stent could be placed. She stayed home, and luminal patency remained until she died 270 days after stent insertion. This report demonstrates that rectal obstruction located less than 5 cm from the anal verge due to Schnitzler's metastasis could be treated by stenting without any symptomatic or technical complications.

  12. Endoscopic ultrasound-guided biliary drainage with placement of a fully covered metal stent for malignant biliary obstruction

    Institute of Scientific and Technical Information of China (English)

    Tae Hyeon Kim; Seong Hun Kim; Hyo Jeong Oh; Young Woo Sohn; Seung Ok Lee

    2012-01-01

    AIM:To determine the utility of endoscopic ultrasoundguided biliary drainage (EUS-BD) with a fully covered self-expandable metal stent for managing malignant biliary stricture.METHODS:We collected data from 13 patients who presented with malignant biliary obstruction and underwent EUS-BD with a nitinol fully covered selfexpandable metal stent when endoscopic retrograde cholangiopancreatography (ERCP) fails.EUS-guided choledochoduodenostomy (EUS-CD) and EUS-guided hepaticogastrostomy (EUS-HG) was performed in 9 patients and 4 patients,respectively.RESULTS:The technical and functional success rate was 92.3% (12/13) and 91.7% (11/12),respectively.Using an intrahepatic approach (EUS-HG,n =4),there was mild peritonitis (n =1) and migration of the metal stent to the stomach (n =1).With an extrahepatic approach (EUS-CD,n =10),there was pneumoperitoneum (n =2),migration (n =2),and mild peritonitis (n =1).All patients were managed conservatively with antibiotics.During follow-up (range,1-12 mo),there was re-intervention (4/13 cases,30.7%) necessitated by stent migration (n =2) and stent occlusion (n =2).CONCLUSION:EUS-BD with a nitinol fully covered self-expandable metal stent may be a feasible and effective treatment option in patients with malignant biliary obstruction when ERCP fails.

  13. Stenting for malignant colonic obstruction: a comparison of efficacy and complications in colonic versus extracolonic malignancy.

    Science.gov (United States)

    Keswani, Rajesh N; Azar, Riad R; Edmundowicz, Steven A; Zhang, Qin; Ammar, Tarek; Banerjee, Bhaskar; Early, Dayna S; Jonnalagadda, Sreenivasa S

    2009-03-01

    Self-expandable metal stent placement for palliation of malignant colonic obstruction for colorectal cancer (CRC) is safe and efficacious. In contrast, outcomes of stent placement for extracolonic malignancy (ECM) are unclear. To compare the success and complication rates of colorectal stenting in patients with CRC versus those with ECM. Retrospective chart review. Tertiary-care academic medical center. Between September 2000 and December 2007, all patients with malignant colon obstruction in whom endoscopy was performed with the intention of placing a colonic metal stent. Technical and clinical success rates, surgical interventions, and procedure-related complications. Colonic stenting was performed for CRC in 34 patients and for ECM in 15 patients. Patients with CRC were more likely to have clinical success after all endoscopic therapy (94.1%) than those with ECM (20.0%) (P analysis (hazard ratio 21.0, P = .0013). A history of radiation therapy was the sole predictor of complications (hazard ratio 7.8, P = .048). Single institution, retrospective analysis, relatively small sample size. Colon stenting for large-bowel obstruction from ECM is infrequently successful and is associated with a significantly higher risk of complications in comparison with patients with CRC.

  14. Palliative gastrojejunostomy versus endoscopic stent placement for gastric outlet obstruction in patients with unresectable gastric cancer: a propensity score-matched analysis.

    Science.gov (United States)

    Jang, Seung Hyeon; Lee, Hyuk; Min, Byung-Hoon; Kim, Su Mi; Kim, Hye Seung; Carriere, Keumhee C; Min, Yang Won; Lee, Jun Haeng; Kim, Jae J

    2017-03-09

    It remains unclear whether selection of treatment modality affects the survival of patients with malignant gastric outlet obstruction (GOO). We compared the effect of gastrojejunostomy (GJ) and endoscopic self-expandable metallic stent (SEMS) placement on the long-term outcomes of patients with malignant GOO caused by unresectable gastric cancer. We conducted a retrospective study of gastric cancer patients undergoing GJ or endoscopic SEMS placement for the palliation of malignant GOO. To reduce the effect of selection bias, we performed a propensity score-matching analysis between two groups. In a propensity-matched analysis (45 and 99 in GJ and SEMS groups, respectively), clinical success rates were comparable between the GJ and SEMS groups (95.6 and 96.0%), while the SEMS group showed significantly shorter hospital stays than the GJ group. The GJ group showed a significantly longer reintervention period and overall survival (393 and 129 days) compared to the SEMS group. In multivariate Cox regression analysis, GJ, low ECOG scale (good performance status), and additional chemo- or radiation therapy were identified as independent favorable predictors of overall survival. GJ was also identified as an independent protective predictor against reintervention. We found that palliative GJ was significantly associated with longer overall survival and lower risk of reintervention than SEMS placement in patients with malignant GOO caused by unresectable gastric cancer. Given very limited expected survival in selected patients with unresectable gastric cancer and more favorable short-term outcomes in cases of SEMS placement, individualized approach might be required in treatment decision between palliative GJ and SEMS placement.

  15. Novel method of stent insertion for malignant lower rectal obstruction with proximal releasing delivery system (with video).

    Science.gov (United States)

    Lee, Kee Myung; Lim, Sun Gyo; Shin, Sung Jae; Kim, Jin Hong; Kang, Dae Hwan; Kim, Jae Keun; Hwang, Jae Chul; Kwon, Chang-Il; Cheong, Jae Yeon; Yoo, Byung Moo

    2013-12-01

    Self-expandable metal stents are an alternative to preoperative and palliative colostomy for patients with malignant colorectal obstruction. However, self-expandable metal stent placement is considered unsuitable or contraindicated for patients with malignant lower rectal obstruction within 5 cm of the anal verge because the exposed stent portion can irritate the distal rectum and cause anal pain and a foreign body sensation. To describe our experience with 6 patients with malignant lower rectal obstruction who underwent stent insertion with a proximal releasing delivery system (PRDS). Prospective clinical series outcome study. A tertiary-care referral university hospital. This study involved all patients at our center who had a malignant lower rectal obstruction within 5 cm of the anal verge caused by rectal cancer and bladder cancer. Uncovered stent with the PRDS with endoscopic and fluoroscopic guidance. Technical and clinical success rate, adverse event rate, and stent migration rate. All stents were placed at the expected location. Technical and clinical success rates were 100%. Two patients reported anal pain, which was controlled with analgesics. One case of tumor ingrowth occurred after 5 months and was treated with reinsertion of a stent with the PRDS. After stent insertion, the patients received chemotherapy, chemoradiotherapy, or conservative care. Small number of patients and no comparison group. Further prospective, randomized, controlled trials are needed. Uncovered stent insertion with the PRDS is a feasible, safe, and effective treatment for the patient with malignant lower rectal obstruction within 5 cm from the anal verge. Copyright © 2013. Published by Mosby, Inc.

  16. Gastrointestinal stenting

    Energy Technology Data Exchange (ETDEWEB)

    Zollikofer, C.L.; Schoch, E. [Dept. of Radiology, Kantonsspital Winterthur (Switzerland); Jost, R. [Dept. of Gastroenterology Internal Medicine, Kantonsspital Winterthur (Switzerland); Decurtins, M. [Dept. of Surgery, Kantonsspital Winterthur (Switzerland)

    2000-02-01

    Acute obstructions of the gastric outlet, the duodenum, or the large bowel require rapid treatment to relieve symptoms of retention or ileus. Large-caliber stents of 16 to 22 mm offer a new non-surgical alternative for treating these patients with minimal risks and high success rates. For gastroduodenal outlet obstructions palliated by self-expanded metal stents, clinical success rates are in the range of 80-100 %. Preoperative treatment of colorectal obstructions successfully relieves acute symptoms of ileus in 87-100 % allowing primary anastomosis and thereby reducing the costs caused by multiple operations and the need of intensive care by approximately 25 %. It is the purpose of this review to familiarize the reader with the indications, possibilities, and limits of intestinal stenting. (orig.)

  17. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong [Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-06-15

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT.

  18. Endoscopic Stenting as Bridge to Surgery versus Emergency Resection for Left-Sided Malignant Colorectal Obstruction: An Updated Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Niccolò Allievi

    2017-01-01

    Full Text Available Introduction. Emergency resection represents the traditional treatment for left-sided malignant obstruction. However, the placement of self-expanding metallic stents and delayed surgery has been proposed as an alternative approach. The aim of the current meta-analysis was to review the available evidence, with particular interest for the short-term outcomes, including a recent multicentre RCT. Methods. We considered randomized controlled trials comparing stenting as a bridge to surgery and emergency surgery for the management of left-sided malignant large bowel obstruction, performing a systematic review in MEDLINE, PubMed database, and the Cochrane libraries. Results. We initially identified a total of 2543 studies. After the elimination of duplicates and the screening of titles and abstracts, seven studies, for a total of 448 patients, were considered. The current meta-analysis revealed no difference in the mortality rate between the stent group and the emergency surgery group; the postoperative complication rate (37.84% versus 54.87%, P=0.02, the stoma rate (28.8% versus 46.02%, P<0.0001, and the incidence of wound infection (8.11% versus 15.49%, P=0.01 were reduced after stent as a bridge to surgery. Conclusion. Colonic stenting as a bridge to surgery appears to be a safe approach to malignant large bowel obstruction. Possible advantages of this treatment can be identified in a reduced incidence of postoperative complications and a lower stoma rate. Further RCTs considering long-term outcomes and cost-effectiveness analysis are needed.

  19. The New Nitinol Conformable Self-Expandable Metal Stents for Malignant Colonic Obstruction: A Pilot Experience as Bridge to Surgery Treatment

    Directory of Open Access Journals (Sweden)

    Roberto Di Mitri

    2014-01-01

    Full Text Available Introduction. Self-expandable metal stents (SEMS are a nonsurgical option for treatment of malignant colorectal obstruction also as a bridge to surgery approach. The new nitinol conformable stent has improved clinical outcomes in these kinds of patients. We report a pilot experience with nitinol conformable SEMS placement as bridge to surgery treatment in patients with colorectal obstruction. Materials and Methods. Between April and August 2012, we collected data on colonic nitinol conformable SEMS placement in a cohort of consecutive symptomatic patients, with malignant colorectal obstruction, who were treated as a bridge to surgery. Technical success, clinical success, and adverse events were recorded. Results. Ten patients (7 male (70%, with a mean age of 69.2 ± 10.1, were evaluated. The mean length of the stenosis was 3.6 ± 0.6 cm. Five patients (50% were treated on an emergency basis. The median time from stent placement to surgery was 16 days (interquartile range 7–21. Technical and clinical success was achieved in all patients with a significant early improvement of symptoms. No adverse events due to the SEMS placement were observed. Conclusion. This pilot study confirmed the important role of nitinol conformable SEMS as a bridge to surgery option in the treatment of symptomatic malignant colorectal obstruction.

  20. Placement of ¹²⁵I seed strands and stents for a type IV Klatskin tumor.

    Science.gov (United States)

    Zhang, Wen; Yang, Zheng-Qiang; Shi, Hai-Bin; Liu, Shen; Zhou, Wei-Zhong; Zhao, Lin-Bo

    2015-01-07

    Herein, we report a new technique that consists of placing two (125)I seed strands and two stents in the right and left intrahepatic bile ducts for the treatment of hilar cholangiocarcinoma. A 75-year-old man presented with jaundice and was diagnosed with Bismuth type IV Klatskin tumor. Abdominal computed tomography (CT) showed intrahepatic and extrahepatic bile duct dilatation and a soft tissue mass in the hepatic hilum. Because curative surgical resection was not possible, we placed (125)I seed strands and stents in the right and left intrahepatic bile ducts. Three months later, abdominal CT showed less intrahepatic and extrahepatic bile duct dilatation than before the procedure. This technique was feasible and could be considered for the treatment of patients with Bismuth type IV tumors.

  1. Role of Montgomery salivary stent placement during pharyngolaryngectomy, to prevent pharyngocutaneous fistula in high-risk patients.

    Science.gov (United States)

    Bondi, S; Giordano, L; Limardo, P; Bussi, M

    2013-01-01

    To evaluate the incidence of pharyngocutaneous fistula after pharyngolaryngectomy with and without a Montgomery salivary stent. Retrospective analysis of patients with factors that predispose to the development of pharyngocutaneous fistula (i.e. disease extending to the supraglottic region, base of the tongue or pyriform sinuses, and/or radiochemotherapy). Between 2002 and 2008, 85 pharyngolaryngectomies were performed in our clinic. Of these patients, 31 were at increased risk of fistula development, of whom 45 per cent developed fistulas post-operatively. This subgroup of 31 patients was compared with a second subgroup of 22 patients at high risk of fistula development, treated between 2009 and 2011 with pharyngolaryngectomy and with a Montgomery salivary stent placed in advance during closure of the neopharynx. Statistical analysis showed a significant reduction in the rate of fistula development, from 45 to 9 per cent (p fistula development.

  2. EUS-Guided Antegrade Transhepatic Placement of a Self-Expandable Metal Stent in Hepatico-Jejunal Anastomosis

    Directory of Open Access Journals (Sweden)

    Everson LA Artifon

    2011-11-01

    Full Text Available Context To demonstrate an EUS-guided biliary drainage in patient with gastrointestinal tract modified surgically. Case report An EUS guided access to the left intra hepatic duct, followed by an antegrade passage of a partially self-expandable metal stent that was removed by using an enteroscope, in one patient with hepatico-jejunal anastomosis. There were no early or delayed complications and the procedure was effective in relieving jaundice until the self-expandable metal stent was removed, 3 months later. A cholangiogram was obtained via enteroscopy, after removal of self-expandable metal stent, and found to be normal. The patient had an uneventful evaluation afterwards. Conclusion The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. EUS-guided biliary drainage is feasible when performed by professionals with expertise in biliopancreatic endoscopy and advanced echo-endoscopy and should be performed currently under rigorous protocol in educational institutions.

  3. Stent Placement in a Neonate with Sano Modification of the Norwood using Semi-Elective Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Mustafa Gulgun

    Full Text Available Abstract Extracorporeal membrane oxygenation (ECMO is a well-established tool of cardiopulmonary circulatory support for cardiopulmonary failure in children and adults. It has been used as a supportive strategy during interventional procedures in neonates with congenital heart disease. Herein, we describe a neonate with hypoplastic left heart syndrome who underwent stenting of the Sano shunt and left pulmonary artery after Norwood Sano operation using intra-procedural ECMO support. The use of ECMO as a bridge to recovery might be a feasible and reasonably safe adjunctive approach in the treatment of complications in selective case of neonates having undergone the Norwood Sano procedure.

  4. Stent Placement in a Neonate with Sano Modification of the Norwood using Semi-Elective Extracorporeal Membrane Oxygenation

    Science.gov (United States)

    Gulgun, Mustafa; Slack, Michael

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is a well-established tool of cardiopulmonary circulatory support for cardiopulmonary failure in children and adults. It has been used as a supportive strategy during interventional procedures in neonates with congenital heart disease. Herein, we describe a neonate with hypoplastic left heart syndrome who underwent stenting of the Sano shunt and left pulmonary artery after Norwood Sano operation using intra-procedural ECMO support. The use of ECMO as a bridge to recovery might be a feasible and reasonably safe adjunctive approach in the treatment of complications in selective case of neonates having undergone the Norwood Sano procedure.

  5. Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction: Effectiveness and Efficacy on 255 Patients with 12-Month's Follow-up

    Science.gov (United States)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G.; Repici, Alessandro; Xinopoulos, Dimitrios; Grund, Karl E.; Goldberg, Paul; Registry Group, The WallFlex Colonic

    2012-01-01

    Background. Self-expanding metal stents can alleviate malignant colonic obstruction in incurable patients and avoid palliative stoma surgery. Objective. Evaluate stent effectiveness and safety on palliation of patients with malignant colorectal strictures. Design. Two prospective, one Spanish and one global, multicenter studies. Settings. 39 centers (22 academic, 17 community hospitals) from 13 countries. Patients. A total of 257 patients were enrolled, and 255 patients were treated with a WallFlex uncovered enteral colonic stent. Follow-up was up to 12 months or until death or retreatment. Interventions(s). Self-expanding metal stent placement. Main Outcome Measures. Procedural success, clinical success, and safety. Results. Procedural success was 98.4% (251). Clinical success rates were 87.8% at 30 days, 89.7% at 3 months, 92.8% at 6 months, and 96% at 12 months. Overall perforation rate was 5.1%. Overall migration rate was 5.5%. Overall death rate during follow-up was 48.6% (124), with 67.7% of deaths related to the patient's colorectal cancer, unrelated in 32.3%. Only 2 deaths were related to the stent or procedure. Limitations. No control group. Conclusions. The primary palliative option for patients with malignant colonic obstruction should be self-expanding metal stent placement due to high rates of technical success and efficacy in symptom palliation and few complications. PMID:22761609

  6. Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction: Effectiveness and Efficacy on 255 Patients with 12-Month's Follow-up

    Directory of Open Access Journals (Sweden)

    Søren Meisner

    2012-01-01

    Full Text Available Background. Self-expanding metal stents can alleviate malignant colonic obstruction in incurable patients and avoid palliative stoma surgery. Objective. Evaluate stent effectiveness and safety on palliation of patients with malignant colorectal strictures. Design. Two prospective, one Spanish and one global, multicenter studies. Settings. 39 centers (22 academic, 17 community hospitals from 13 countries. Patients. A total of 257 patients were enrolled, and 255 patients were treated with a WallFlex uncovered enteral colonic stent. Follow-up was up to 12 months or until death or retreatment. Interventions(s. Self-expanding metal stent placement. Main Outcome Measures. Procedural success, clinical success, and safety. Results. Procedural success was 98.4% (251. Clinical success rates were 87.8% at 30 days, 89.7% at 3 months, 92.8% at 6 months, and 96% at 12 months. Overall perforation rate was 5.1%. Overall migration rate was 5.5%. Overall death rate during follow-up was 48.6% (124, with 67.7% of deaths related to the patient’s colorectal cancer, unrelated in 32.3%. Only 2 deaths were related to the stent or procedure. Limitations. No control group. Conclusions. The primary palliative option for patients with malignant colonic obstruction should be self-expanding metal stent placement due to high rates of technical success and efficacy in symptom palliation and few complications.

  7. Renal Artery Stent Outcomes

    Science.gov (United States)

    Murphy, Timothy P.; Cooper, Christopher J.; Matsumoto, Alan H.; Cutlip, Donald E.; Pencina, Karol M.; Jamerson, Kenneth; Tuttle, Katherine R.; Shapiro, Joseph I.; D’Agostino, Ralph; Massaro, Joseph; Henrich, William; Dworkin, Lance D.

    2016-01-01

    BACKGROUND Multiple randomized clinical trials comparing renal artery stent placement plus medical therapy with medical therapy alone have not shown any benefit of stent placement. However, debate continues whether patients with extreme pressure gradients, stenosis severity, or baseline blood pressure benefit from stent revascularization. OBJECTIVES The study sought to test the hypothesis that pressure gradients, stenosis severity, and/or baseline blood pressure affects outcomes after renal artery stent placement. METHODS Using data from 947 patients with a history of hypertension or chronic kidney disease from the largest randomized trial of renal artery stent placement, the CORAL (Cardiovascular Outcomes in Renal Atherosclerotic Lesions) study, we performed exploratory analyses to determine if subsets of patients experienced better outcomes after stent placement than the overall cohort. We examined baseline stenosis severity, systolic blood pressure, and translesion pressure gradient (peak systolic and mean) and performed interaction tests and Cox proportional hazards analyses for the occurrence of the primary endpoint through all follow-up, to examine the effect of these variables on outcomes by treatment group. RESULTS There were no statistically significant differences in outcomes based on the examined variables nor were there any consistent nonsignificant trends. CONCLUSIONS Based on data from the CORAL randomized trial, there is no evidence of a significant treatment effect of the renal artery stent procedure compared with medical therapy alone based on stenosis severity, level of systolic blood pressure elevation, or according to the magnitude of the transstenotic pressure gradient. (Benefits of Medical Therapy Plus Stenting for Renal Atherosclerotic Lesions [CORAL]; NCT00081731) PMID:26653621

  8. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  9. WallFlex™ Duodenal Stent Placement in a Gastric Cancer Patient with Malignant Stenosis of a Roux-en-Y Gastrojejunostomy following Distal Gastrectomy

    Directory of Open Access Journals (Sweden)

    Tomoyuki Kakuta

    2012-10-01

    Full Text Available A 69-year-old Japanese woman with a history of distal gastrectomy with a Roux-en-Y reconstruction for advanced gastric cancer was admitted to our hospital complaining of severe dysphagia. On admission, the patient was only able to take liquids, and a firm, fist-sized tumor was palpable in her left upper abdomen. An endoscopic examination disclosed stenosis of the jejunal limb of the gastrojejunostomy. Abdominal computed tomography revealed that a recurrent tumor, 5.0 cm in diameter, was compressing the jejunal limb of the gastrojejunostomy. A knitted nitinol self-expandable metallic stent (WallFlex™ duodenal stent was placed endoscopically at the stenotic jejunum from the gastrojejunostomy. The time required for stenting and total endoscopic manipulation was 12 and 35 minutes, respectively. No stent-related complications were observed. The patient could resume oral ingestion 1 day after endoscopic stenting and was discharged on the fifth day after treatment. She survived for 201 days after stenting. She continued oral ingestion for 194 days and stayed at home for 165 days. The WallFlex duodenal stent allows safe endoscopic stenting, even in cases of malignant stenosis of a gastrojejunostomy following distal gastrectomy. This stenting device will extend the indications for endoscopic palliation of gastric cancer patients with gastric outlet stenosis.

  10. Clinical Outcomes of Colonic Stent in a Tertiary Care Center

    Directory of Open Access Journals (Sweden)

    Mahesh Gajendran

    2014-01-01

    Full Text Available Introduction. Colonic obstruction is one of the manifestations of colon cancer for which self-expanding metal stents (SEMS have been effectively used, to restore the luminal patency either for palliative care or as a bridge to resective surgery. The aim of our study is to evaluate the efficacy and safety of large diameter SEMS in patients with malignant colorectal obstruction. Methods and Results. A four-year retrospective review of the Medical Archival System was performed and identified 16 patients. The average age was 70.8 years, of which 56% were females. The most common cause of obstruction was colon cancer (9/16, 56%. Rectosigmoid was the main site of obstruction (9/16 and complete obstruction occurred in 31% of cases. The overall technical and clinical success rates were 100% and 87%, respectively. There were no immediate complications (<24 hours, but stent stenosis due to kinking occurred within one week of stent placement in 2 patients. Stent migration occurred in 2 patients at 34 and 91 days, respectively. There were no perforations or bleeding complications. Conclusion. Large diameter SEMS provide a safe method for palliation or as a bridge to therapy in patients with malignant colonic obstruction with high technical success and very low complication rates.

  11. Angioplasty and stent placement - heart

    Science.gov (United States)

    ... angioplasty; Coronary artery angioplasty; Percutaneous transluminal coronary angioplasty; Heart artery dilatation ... to carefully guide the catheter up into your heart and arteries. Dye will be injected into your ...

  12. Ureteral Stent Placement for Ureteral Calculi during Pregnancy:An Analysis of 50 Cases%输尿管支架置入术治疗孕期输尿管结石50例临床分析

    Institute of Scientific and Technical Information of China (English)

    王进峰; 卢晓明; 王礼平; 尹九湖

    2015-01-01

    ABSTRACT:Objective To explorer the value of ureteral stent placement in the treatment of ure-teral calculi during pregnancy.Methods Clinical data of 50 patients who underwent ureteral stent placement for ureteral calculi during pregnancy were retrospectively analyzed.Auxiliary examina-tion confirmed that all patients had ureteral calculi complicated by renal colic and failed to respond to conservative drug treatment.Among the 50 patients,25 had right ureteral calculi,22 had left u-reteral calculi,3 had bilateral ureteral calculi,31 had middle/upper ureteral calculi,and 19 had lower ureteral calculi.Results Thirty-seven patients successfully underwent cystoscopic catheter-ization after topical anesthesia.Twelve patients underwent successful ureteroscopic catheterization after failed cystoscopic catheterization.One patient underwent successful percutaneous renal an-terograde catheterization under local anaesthesia after failed retrograde catheterization.After treatment,renal colic was relieved obviously and hydronephrosis was alleviated to varying degrees with no threatened abortion in all patients.Postoperative reexamination showed that ureteral stents were placed appropriately in 48 patients and were located in upper ureter in 1 patient.In ad-dition,ureteral stents fell out in 1 patient when urinary catheter was removed on postoperative day 3.However,ureteral stents were appropriately placed after recatheterization in this patient. Conclusion Ureteral stent placement is a simple,effective,safe and reliable treatment for ureteral calculi during pregnancy.%目的:探讨输尿管支架置入术在治疗孕期输尿管结石中的应用价值。方法对50例输尿管支架置入术治疗的孕期输尿管结石患者的临床资料进行回顾性分析。50例患者均经辅助检查证实输尿管结石,同时合并肾绞痛,经药物保守治疗无效,其中右输尿管结石25例、左输尿管结石22例、双侧输尿管结石3例,31例

  13. Three-dimensional CT imaging and virtual endoscopy for the placement of self-expandable stents in oesophageal and tracheobronchial neoplastic stenoses.

    Science.gov (United States)

    Di Simone, M P; Mattioli, S; D'Ovidio, F; Bassi, F

    2003-01-01

    We examined the value of multislice computed tomography (CT) with three-dimensional (3D) reconstruction of the images as a pre-treatment examination in order to plan endoluminal stenting in 14 patients with large tumours involving the oesophagus and/or the tracheobronchial tree. The measurement of the stenosis obtained during 3D reconstruction of the CT images corresponded to that obtained by endoscopy and to the prosthesis chosen in all cases, with the exception of one patient undergoing double stenting due to inadequate gaseous distension of the oesophageal lumen. 3D CT may add information with respect to axial imaging, and be helpful to better plan and perform stenting of the oesophagus and airways without burdening the preoperative work-up.

  14. Forgotten Ureteral Stents: An Avoidable Morbidity.

    Science.gov (United States)

    Murtaza, Badar; Alvi, Sarwar

    2016-03-01

    To assess the clinical presentation of forgotten ureteral stents and highlight the etiological factors resulting in the retention of these stents. Observational study. Department of Urology, Armed Forces Institute of Urology, Rawalpindi, from January 2010 to June 2011. Thirty-eight patients, with forgotten ureteral stents, retained for more than 6 months duration, were enrolled. A detailed evaluation was performed, along with the questions regarding the patients' opinion about the ureteral stents. They were specially asked whether they knew about the stents or were they formally informed regarding the stents. Subsequently, the patients were managed according to their clinical condition. The male to female ratio was 2.1:1 aged 23 - 69 years, mean being 40.24 ±12.59 years. The time of presentation after the ureteral stenting was 7 - 180 months (mean = 28.89 ±33.435 years). Seven patients (18.4%) reported with chronic kidney disease, including ESRD in two cases. Recurrent UTI was seen in 28 cases (73.6%), calculus formed over the stents in 20 cases (52.6%), and stent fragmented in 5 patients (13.1%). Majority of patients, (n = 23, 60.5%), were not even aware of the placement of these stents while 8 (21.0%) knew but were reluctant about its removal. In 3 cases (7.8%), the relatives knew about the stent but never informed the patients. The stent had been removed in 2 cases (5.2%), but the other broken fragment was missed. One case (2.6%) each had a misconception about the permanent placement of the stents like cardiac stents and regarding degradation of the stents in situ. Forgotten ureteral stents produce clinical features ranging from recurrent UTI to ESRD. This preventable urological complication is primarily due to the unawareness or ignorance of the patients and their relatives regarding the stent.

  15. Endovascular treatment of ruptured abdominal aortic aneurysm with aortocaval fistula based on aortic and inferior vena cava stent-graft placement.

    Science.gov (United States)

    Silveira, Pierre Galvagni; Cunha, Josué Rafael Ferreira; Lima, Guilherme Baumgardt Barbosa; Franklin, Rafael Narciso; Bortoluzzi, Cristiano Torres; Galego, Gilberto do Nascimento

    2014-11-01

    A ruptured abdominal aortic aneurysm (RAAA), complicated by an aortocaval fistula (ACF), is usually associated with high morbidity and mortality during open operative repair. We report a case of endovascular treatment of an RAAA with ACF. After accessing both common femoral arteries, a bifurcated aortic stent graft was placed. Subsequently, we accessed the fistula from the right femoral vein and a cava vein angiography showed a persistent massive flow from the cava to the excluded aneurysm sac. We proceeded by covering the fistula with an Excluder aortic stent-graft cuff to prevent pressurization of the aneurysm sac and secondary endoleaks. This procedure is feasible and may reduce the chances of posterior endoleaks.

  16. Balloon-expandable Metallic Stents for Airway Diseases.

    Science.gov (United States)

    Ohki, Takashi; Sugimoto, Seiichiro; Kurosaki, Takeshi; Otani, Shinji; Miyoshi, Kentaroh; Yamane, Masaomi; Miyoshi, Shinichiro; Oto, Takahiro

    2016-10-01

    Stent placement is an essential treatment for airway diseases. Although self-expandable metallic stents and silicone stents are commonly applied for the treatment of airway diseases, these stents are unsuitable for the treatment of small airway diseases encountered in pediatric patients and lung transplant recipients with airway complications. Currently, only vascular balloon-expandable metallic stents are available for the treatment of small airway diseases; however, little research has been conducted on the use of these stents in this field. We have launched a prospective feasibility study to clarify the safety and efficacy of balloon-expandable metallic stents for the treatment of airway diseases.

  17. Self-expanding metal stents in malignant esophageal obstruction: a comparison between two stent types.

    Science.gov (United States)

    Schmassmann, A; Meyenberger, C; Knuchel, J; Binek, J; Lammer, F; Kleiner, B; Hürlimann, S; Inauen, W; Hammer, B; Scheurer, U; Halter, F

    1997-03-01

    Self-expanding metal stents are a promising alternative in the palliation of malignant esophageal obstruction, but the relative value of different stent types is not well established. During a 3-year enrollment period in four different centers, 82 consecutive patients with malignant dysphagia without tumor recurrence after surgery or esophagorespiratory fistulas received either an uncovered Wallstent (44 patients) or a knitted nitinol stent (38 patients). Age (median: 79 yr), sex (F:M = 33:67), dysphagia score (median: 3), Karnofsky score (median: 53), body mass index (median: 19), type of pretreatment, tumor stage, stricture length (median: 5.4 cm), and stricture location were comparable in both stent groups. After stent placement, median dysphagia score improved markedly in both groups by two points. Procedure-related mortality (16 vs 0%; p < 0.01), early complication rate (32 vs 8%; p < 0.01), and severe persistent pain after stent placement (23 vs 0%; p < 0.002) were higher in the Wallstent compared with the knitted nitinol stent group. In contrast, stent dysfunction (7 vs 32%; p < 0.005), reintervention rate (9 vs 34%; p < 0.005), and costs were lower in the Wallstent compared with the nitinol stent group. In malignant esophageal obstruction, both stents markedly improved dysphagia. Uncovered Wallstents seem to cause more early severe complications than knitted nitinol stents. In contrast, stent dysfunction, reintervention rate, and costs appear to be higher in the nitinol stent group.

  18. Obstructed surgical porto-systemic shunts in the early postoperative period: interventional therapy by angioplasty (PTA) and stent placement; Obstruktion chirurgischer portosystemischer Shunts in der fruehen postoperativen Phase: interventionelle Behandlung durch Angioplastie und Stentimplantation

    Energy Technology Data Exchange (ETDEWEB)

    Strunk, H.; Textor, J.; Koenig, R.; Wilhelm, K.; Schild, H. [Bonn Univ. (Germany). Radiologische Klinik; Wolff, M. [Bonn Univ. (Germany). Chirurgische Klinik und Poliklinik

    2001-05-01

    Recurrent variceal bleeding in patients treated with surgical porto-systemic shunting is most often due to shunt stenoses or occlusion. Radiological interventional procedures are a possible method of therapy and our experience herein is described in this report. Patients and Methods: from 1997 to 1999 54 patients with recurrent variceal bleeding were treated with a surgical porto-systemic shunt procedure. Of these early shunt occlusion occurred in 5 patients, which was treated with percutaneous transcatheter techniques. Results: in only one patient was PTA alone sufficient to reestablish shunt patency, in four patient stent placement was necessary in addition. In the follow-up period 1 patient died 26 month after intervention with (autopsy-proven) patent shunt, in one patient shunt reocclusion occurred after 11 months and in 3 patients the shunt is still patent. Conclusions: PTA, if necessary in combination with stent placement, is an attractive alternative method of therapy in case of an early surgical porto-systemic shunt occlusion. (orig.) [German] Rezidivblutungen nach chirurgischer portosystemischer Shuntanlage sind meistens durch eine Shuntstenose oder einen Shuntverschluss bedingt. Hier stellen interventionelle Eingriffe einen moeglichen therapeutischen Ansatz dar, ueber den im Folgenden berichtet werden soll. Patienten und Methode: zwischen 1997 und 1999 wurde bei insgesamt 54 Patienten wegen rezidivierender Blutungen ein operativer portosystemischer Shunt angelegt. Von diesen zeigten fuenf Patienten in der unmittelbaren postoperativen Periode einen Shuntverschluss, der radiologisch interventionell therapiert wurde. Ergebnisse: bei einem der fuenf Patienten genuegte zur Wiederherstellung des Flusses eine alleinige Ballondilatation (PTA), bei vier Patienten musste zusaetzlich eine Stentimplantation durchgefuehrt werden. In der weiteren Nachsorge ist ein Pat. nach 26 Wochen mit autoptisch offenem Shunt verstorben, bei 3 Pat. ist der Shunt offen, bei einem

  19. [Multi-modarity treatment for colon liver metastases using biliary stent-report of a case].

    Science.gov (United States)

    Hasegawa, Hirofumi; Kudo, Kensuke; Kitagawa, Dai; Nakamura, Toshihiko; Shohji, Fumihiro; Kabashima, Akira; Teramoto, Seiichi; Funahashi, Wataru; Kitamura, Masayuki

    2013-11-01

    We report the case of a 69-year-old male patient with diagnoses of sigmoid colon cancer, ascending colon cancer, and metastatic liver cancer. We performed sigmoidectomy, right hemicolectomy, and central venous port placement. Because the liver metastasis was multifocal, chemotherapy was first initiated and then hepatic resection was performed. However, during chemotherapy, ileus, with a peritoneal dissemination to the small intestine, developed. Small intestine resection and radiation therapy to the pelvic region of the transition were further performed. Thereafter, obstructive jaundice due to obstruction of the bile duct in the hilar area developed, and therefore, we inserted a biliary stent. However, 2 years 9 months after the first medical examination, this patient died of colon cancer. The guidelines above, still chemotherapy developed, treatment policy of recurrent colorectal cancer, have recommended surgical resection with respect to what resectable as local therapy. This case shows that combination therapy with chemotherapy, surgical therapy, radiation therapy, and local therapy such as biliary stenting, is useful.

  20. Evaluation of short-term therapeutic efficacy of stent placement in hepatocellular carcinoma associated with inferior vena cava obstruction%支架置入术治疗原发性肝癌并下腔静脉阻塞的近期疗效观察

    Institute of Scientific and Technical Information of China (English)

    吴育民; 周汝明; 梁惠民; 邱水波; 刘闽华; 戴懿; 庄少育

    2011-01-01

    目的:探讨支架置入术治疗原发性肝癌并下腔静脉阻塞的近期疗效.方法:回顾性分析对30例因原发性肝癌并下腔静脉阻塞行介入治疗的患者资料.其中24例仅行下腔静脉支架置人术.4例行下腔静脉及右心房联合支架置入术.2例行下腔静脉及肝静脉联合支架置入术.观察其近期疗效.并对其进行评价分析.结果:30例患者支架置入术均成功.未发现有任何严重手术并发症.术后患者Child-Push分级及临床症状较术前明显改善(P<0.05).结论:支架置入术治疗肝癌并发下腔静脉阻塞的短期疗效显著.可使患者获得进一步积极治疗的机会.%Objective:The purpose of this study was to evaluate short-term therapeutic efficacy of stent placement in heparocellular carcinoma ( HCC) associated with inferior vena cava obstruction. Methods: A retrospective analysis was conducted of 30 patients who sufferd from HCC accompanied with inferior vena cava obstruction and received interventional therapy. Twenty-four ptients were merely treated with inferior vena cava stent placement, 4 patients underwent inferior vena cava and right atrium conbined stent placement, and 2 patients underwent inferior vena cava and hepatic vein conbined stent placement. Technical success. complication and short-term response to treatment. including Child-Pugh classification and clinical symptoms, were observed. Results : Stent placement was successfully performed in thirty patients. No complications occurred in these patients. There were significant improvement in Child-Pugh classification and clinical symptoms before and after stent placement ( P <0. 05). Conclusion: Stcnt placement had significant short-term effects on HCC accompanied with inferior vena cava.obstruction, by which some parients were able to be given the opportunity for further aggressive treatment.

  1. The forgotten biliary stent: an unusual cause of diarrhea.

    Science.gov (United States)

    Sran, Harkiran; Sebastian, Joseph; Doughan, Samer

    2016-09-01

    This case highlights the possible complications of biliary stents, which may include migration and impaction in the gastrointestinal tract. It also emphasizes the need for a robust follow-up system after stent placement, to minimize the risks and possible sequelae of a forgotten stent.

  2. Advances in drug eluting stents – focus on the Endeavor® zotarolimus stent

    Directory of Open Access Journals (Sweden)

    Jonathan Bridges

    2008-12-01

    Full Text Available Jonathan Bridges, Donald CutlipBeth Israel Deaconess Medical Center, Boston, Massachusetts, USAAbstract: Coronary artery disease remains one of the leading causes of death in the United States. Over the last 30 years, the development of coronary artery angioplasty and stenting has drastically reduced mortality during acute coronary syndromes while also reducing symptoms of chronic coronary artery disease. Unfortunately, the placement of stents in a coronary artery can be complicated by in-stent thrombosis or restenosis. In 2003–2004, a new generation of stents was introduced to the market with the goal of reducing the rate of restenosis. These stents, called drug eluting stents (DES, are coated with a pharmacological agent designed to reduce the neointimal hyperplasia associated with restenosis. Within a year, approximately 80% of all percutaneous coronary interventions performed within the US involved placement of a DES. In 2006, a controversy arose about the possibility of a statistically significant increased risk of acute stent thrombosis associated with DES especially when used for an “off label” indication. This risk was attributed to delayed endothelization. This controversy has led to a reduction in the use of DES along with longer use of dual platelet inhibition with aspirin and clopidogrel. Recently Medtronic introduced a new DES to the market called the Endeavor® stent – a zotarolimus eluting stent.Keywords: Endeavor® stent, zotarolimus stent, drug eluting stent

  3. Renin-angiotensin system intervention to prevent in-stent restenosis - An unclosed chapter

    NARCIS (Netherlands)

    Langeveld, B; Roks, AJM; Tio, RA; Voors, AA; Zijlstra, F; van Gilst, WH

    2005-01-01

    The occurrence of in-stent restenosis is a major drawback of percutaneous transluminal coronary angioplasty with stent placement. Target vessel revascularization is necessary in 15% of patients who receive a stent. Recent advances in the development of drug-eluting stents have reduced these numbers

  4. Local Delivery of Antiproliferative Agents via Stents

    Directory of Open Access Journals (Sweden)

    Hyuck Joon Kwon

    2014-03-01

    Full Text Available A stent is a medical device for serving as an internal scaffold to maintain or increase the lumen of a body conduit. Stent placement has become a primary treatment option in coronary artery disease for more than the last two decades. The stenting is also currently used for relieving the symptoms of narrowed lumen of nonvascular organs, such as esophagus, trachea and bronchi, small and large intestines, biliary, and urinary tract. Local delivery of active pharmaceutical agents via the stents can not only enhance healing of certain diseases, but it can also help decrease the potential risk of the stenting procedure to the surrounding tissue. In this review, we focus on reviewing a variety of drug-impregnated stents and local drug delivery systems using the stents.

  5. Coronary CT angiography-derived quantitative markers for predicting in-stent restenosis

    NARCIS (Netherlands)

    Tesche, Christian; De Cecco, Carlo N.; Vliegenthart, Rozemarijn; Duguay, Taylor M.; Stubenrauch, Andrew C.; Rosenberg, Russell D.; Varga-Szemes, Akos; Bayer, Richard R.; Yang, Junjie; Ebersberger, Ullrich; Baguet, Moritz; Jochheim, David; Hoffmann, Ellen; Steinberg, Daniel H.; Chiaramida, Salvatore A.; Schoepf, U. Joseph

    2016-01-01

    Objective: To evaluate quantitative markers derived from coronary CT angiography (coronary CTA) performed prior to percutaneous coronary intervention (PCI) with stent placement for predicting in-stent restenosis (ISR) as defined by quantitative coronary angiography (QCA). Materials and methods: We

  6. Percutaneous transfemoral placement of a new flexible stent-graft into the thoracic aorta followed by a percutaneous suture-mediated closure of the access site - initial experience; Perkutane transfemorale implantation einer neuen, flexiblen thorakalen Aortenendoprothese unter Verwendung eines perkutanen Nahtsystems zum Gefaessverschluss - erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Manke, C.; Lenhart, M.; Strotzer, M.; Feuerbach, S.; Link, J. [Klinikum der Univ. Regensburg (Germany). Inst. fuer Roentgendiagnostik; Kobuch, R.; Merk, J.; Birnbaum, F. [Klinikum der Univ. Regensburg (Germany). Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie

    2001-05-01

    To evaluate the transfemoral placement of a new, flexible stent-graft into the thoracic aorta and the suture-mediated closure of the femoral access. Patients and Methods: five patients were treated endovascularly with a stent-graft for an aneurysm (n = 3) or acute dissection (n = 2) of the thoracic aorta via a femoral 24 F sheath. The femoral access site was closed with two suture-mediated closure devices after placement of the stent-graft. Results: the aneurysm or the false lumen was excluded from perfusion by the placement of the stent-graft in all patients. Hemostasis at the femoral access site was successful in all patients with the percutaneous suture device. A minor stenosis of the femoral artery was found angiographically in four patients after suture-mediated closure. Besides a reversible renal failure due to the medically induced hypotension for the treatment of an acutely ruptured aneurysm, no complications resulted from the stent-graft placement or the percutaneous suture. Conclusion: the percutaneous transfemoral placement of stent-grafts in the thoracic aorta using a suture-mediated closure of the access site is technically feasible. Long-term results of the technique have to be awaited. (orig.) [German] Evaluation der transfemoralen Implantation einer neuen, flexiblen thorakalen Aortenprothese unter Verwendung eines perkutanen Nahtsystems zum Verschluss des femoralen Zugangs. Patienten und Methoden: fuenf Patienten wurden wegen Aneurysma (n = 3) oder akuter Dissektion (n = 2) der thorakalen Aorta endovaskulaer ueber eine perkutan eingebrachte 24F-Schleuse mit einem Stentgraft versogt. Der femorale Zugang wurde nach Plazierung der Endoprothese mit zwei perkutanen Nahtgeraeten verschlossen. Ergebnisse: bei allen Patienten fuehrte die Platzierung der Prothese zur Ausschaltung des Aneurysmas oder des falschen Lumens von der Perfusion. Mit der perkutanen Gefae paragraph naht konnte in allen Faellen ein Verschluss des femoralen Zugangs erreicht werden. In

  7. 原位肝移植术后门静脉狭窄内支架植入治疗的随访观察%Follow-up study of percutaneous transhepatic portal vein angioplasty and stent placement after liver transplantation

    Institute of Scientific and Technical Information of China (English)

    王欣; 王剑锋; 黄强; 高堃; 翟仁友; 杨伟利

    2013-01-01

    Objective To evaluate the efifcacy of the stent implantation in treatment of portal vein stenosis or thrombosis after liver transplantation. Methods From November 2004 to August 2012, 31 patients with portal vein stenosis after liver transplantation were referred for angiographic analysis and stent placement treatment successfully. After percutaneous transheptic balloon angioplasty, stents were deployed. Thrombolytic therapy for patients with portal vein thrombosis. Embolization was performed in patients with varices or portal vein lfow changes. The therapeutic results were monitored by the follow-up on clinical symptoms and imaging examinationsin inorder to know about the stent and complications. Results Thirty-nine stents were deployed subsequently. Four patients were given thrombolytic therapy, and 5 patients were given collateral embolization included. All the portal vein recanalized and the symptoms were relieved. Besides, 2 patients with portal vein stenosis and cavernous transformation were given stent placement successfully. Portal vein patency was all maintained in 29 patients for 6-99 months. The cumulative patency rate was 100%. In the follow-up study , the splenic vein thrombosis raised again in one case of portal vein thrombosis (PVT) after 17 months therapy. The short-time severe complication related to interventional therapy is thoracic cavity hemorrhage in 1 cases (3.2%);and the long-term complication is the blood lfown down in the other branch of portal vein in 1 cases (3.2%). Conclusions Interventional therapy is an effective method for the treatment of portal vein stenosis after liver transplantation and has low stent restenosis rate. For the patient with PVT, it still has the risk of thrombosis again in the long-term study. And we should be vigilant for possible complications.%目的:评价肝移植术后门静脉狭窄或伴血栓形成者内支架植入治疗的疗效。方法回顾性分析2004年11月至2012年8月,北

  8. A Dual Expandable Nitinol Stent: The Long-term Results in Patients with Malignant Gastroduodenal Strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hee; Jung, Gyoo Sik; Oh, Kyeung Seung [Kosin University College of Medicine, Busan (Korea, Republic of)

    2009-12-15

    We wanted to evaluate the long-term results of a dual expandable nitinol stent for the palliative treatment of malignant gastroduodenal strictures. The dual stent consists of two stents; an outer partially nylon covered stent and an inner bare nitinol stent. The outer stent was placed into the stricture and this was followed by coaxial placement of the inner bare stent. Using fluoroscopic guidance, dual expandable stents were placed in 86 patients with inoperable malignant gastroduodenal strictures. The technical and clinical success, the complication, survival and the stent patency were evaluated during the follow-up period. Stent placement was technically successful in 83 of the 86 patients. After stent placement, 74 of the 85 patients showed improvement of their symptoms. During the mean follow-up period of 133 days, 24 patients (28%) developed recurrent symptoms due to incomplete expansion (n=1), stent migration (n=4), food impaction (n=2), granulation tissue formation (n=2), tumor overgrowth (n=6), tumor ingrowth (n=1) and stent collapse (n=8). Eleven of them were successfully treated by means of placing a second stent. The median period of stent patency was 212 days (mean, 299 days). The 30-day, 60-day, 90-day and 180-day patency rates were 93%, 84%, 81% and 53%, respectively. The dual expandable nitinol stent seems to be effective for the palliation of malignant gastroduodenal strictures

  9. A Case of Successful Placement of a Fully Covered Metallic Stent for Hemobilia Secondary to Hepatocellular Carcinoma with Bile Duct Invasion

    Directory of Open Access Journals (Sweden)

    Yoshiaki Kawaguchi

    2012-12-01

    Full Text Available Hemobilia represents gastrointestinal bleeding that develops as a result of communication between blood vessels and the biliary tract, which causes the blood to reach the duodenal papilla. It is characterized by biliary colic as the initial symptom, and the complications of cholangitis, obstructive jaundice and/or anemia. In general, definitive diagnosis is made by esophagogastroduodenoscopy which confirms bleeding from the duodenal papilla. Abdominal US and abdominal enhanced CT are performed to identify the source of the bleeding, as well as ERCP for biliary drainage to control the comorbid cholangitis. If active hemorrhage accompanied by worsening of the anemia is suspected, abdominal angiography is performed to selectively image the hepatic artery. Then, embolization of the culprit vessel is recommended. In our patients with difficult hemostasis, because of the direct compression hemostasis to the tumor site achieved with the fully covered metallic stent and secondary compression hemostasis due to blood clots, the bleeding could be controlled.

  10. Bronchial stents

    Directory of Open Access Journals (Sweden)

    Ibrahim Emad

    2006-01-01

    Full Text Available Bronchial stents are mostly used as a Palliative relief of symptoms often caused by airway obstruction, It is also used for sealing of stump fistulas after pneumonectomy and dehiscence after bronchoplastic operations. Advances in airway prosthetics have provided a variety of silicone stents, expandable metal stents, and pneumatic dilators, enabling the correction of increasingly complex anatomical problems. Several series have been published describing the application and results of these techniques. This manuscript reviews the historical development of stents, types, indication, outcome, and complications. Alternative therapies for tracheobronchial stenting were also reviewed

  11. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  12. “双管法”镍钛记忆合金支架置入术治疗气管狭窄和气管瘘的临床应用%Clinical use of "double-barreled" nickel-titanium memory alloy stent placement for treatment of tracheal stenosis and fistula

    Institute of Scientific and Technical Information of China (English)

    魏宁; 顾玉明; 徐浩; 祖茂衡; 张庆桥; 许伟; 崔艳峰; 刘洪涛; 王文亮

    2012-01-01

    Objective To assess the efficacy of "double-barreled" nickel-titanium memory alloy stent placement for treatment of benign or malignant tracheal stenosis and tracheal fistula under local anesthesia and digital subtraction angiography(DSA) monitoring.Methods A retrospective analysis was performed on the profiles of 25 typical cases who received intubation via the nasal cavity or tracheal fistula (O2:2-4 L/min) followed by endotracheal placement of various n ickel-titanium memory alloy stents under DSA monitoring and laryngopharyngeal or tracheal local anesthesia between 2003 and 2011.Results Nickel-titanium stents,including 2 integrated inverted Y-shaped stents,a bullet-like membrane-coated stent,5 tubular membrane-coated stents and 20 tubular common stents,were successflly implanted in 25 patients.Stent placement was associated with marked improvement in dyspnea,and the grading reduced from Ⅲ-Ⅳ to 0- Ⅰ.Furthermore,pulse oxygen saturation (SPO2) was improved to (92.55±3.08)% during spontaneous breathing as compared with (73.24± 3.07)% previously during high-flow oxygen therapy (P< 0.05).Conclusion The "double-barreled" nickel-titanium memory alloy stent placement under local anesthesia and DSA monitoring is worthwhile for clinical application due to its safety,effectiveness and simplicity.%目的 探讨在局麻和数字减影血管造影机(DSA)监视下应用“双管法”置入镍钛记忆合金支架急诊治疗气管良恶性狭窄和气管瘘的疗效.方法 回顾性分析2003-2011年间,在DSA监视和咽喉、气管局麻下,先经鼻或气管瘘口留置通气导管,予以2~4 L/min流量供氧,再经气管置入不同类型镍钛记忆合金气管支架的25个典型病例.结果 25例患者行镍钛记忆合金支架均成功,共置入一体式倒Y型支架2枚,“子弹头”覆膜支架1枚,管状覆膜支架5枚,管状裸支架20枚.所有患者术后呼吸困难明显改善,气促评级由Ⅲ~Ⅳ级改善为0~Ⅰ级,氧饱

  13. Does rectal indomethacin eliminate the need for prophylactic pancreatic stent placement in patients undergoing high-risk ERCP? Post hoc efficacy and cost-benefit analyses using prospective clinical trial data.

    Science.gov (United States)

    Elmunzer, B Joseph; Higgins, Peter D R; Saini, Sameer D; Scheiman, James M; Parker, Robert A; Chak, Amitabh; Romagnuolo, Joseph; Mosler, Patrick; Hayward, Rodney A; Elta, Grace H; Korsnes, Sheryl J; Schmidt, Suzette E; Sherman, Stuart; Lehman, Glen A; Fogel, Evan L

    2013-03-01

    A recent large-scale randomized controlled trial (RCT) demonstrated that rectal indomethacin administration is effective in addition to pancreatic stent placement (PSP) for preventing post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP) in high-risk cases. We performed a post hoc analysis of this RCT to explore whether rectal indomethacin can replace PSP in the prevention of PEP and to estimate the potential cost savings of such an approach. We retrospectively classified RCT subjects into four prevention groups: (1) no prophylaxis, (2) PSP alone, (3) rectal indomethacin alone, and (4) the combination of PSP and indomethacin. Multivariable logistic regression was used to adjust for imbalances in the prevalence of risk factors for PEP between the groups. Based on these adjusted PEP rates, we conducted an economic analysis comparing the costs associated with PEP prevention strategies employing rectal indomethacin alone, PSP alone, or the combination of both. After adjusting for risk using two different logistic regression models, rectal indomethacin alone appeared to be more effective for preventing PEP than no prophylaxis, PSP alone, and the combination of indomethacin and PSP. Economic analysis revealed that indomethacin alone was a cost-saving strategy in 96% of Monte Carlo trials. A prevention strategy employing rectal indomethacin alone could save approximately $150 million annually in the United States compared with a strategy of PSP alone, and $85 million compared with a strategy of indomethacin and PSP. This hypothesis-generating study suggests that prophylactic rectal indomethacin could replace PSP in patients undergoing high-risk ERCP, potentially improving clinical outcomes and reducing healthcare costs. A RCT comparing rectal indomethacin alone vs. indomethacin plus PSP is needed.

  14. Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent

    Energy Technology Data Exchange (ETDEWEB)

    Sofue, Keitaro, E-mail: keitarosofue@yahoo.co.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp [National Cancer Center Hospital, Department of Diagnostic Radiology (Japan); Sugimura, Kazuro, E-mail: sugimura@med.kobe-u.ac.jp [Kobe University, Department of Radiology, Graduate School of Medicine (Japan)

    2013-02-15

    A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.

  15. Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Koepfli, Pascal; Gaemperli, Oliver; Eberli, Franz R.; Luescher, Thomas F. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Leschka, Sebastian; Desbiolles, Lotus; Husmann, Lars; Wildermuth, Simon; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2007-06-15

    We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 {+-} 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 {+-} 0.39 mm versus 2.49 {+-} 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 {+-} 6.2 mm, correlating well with CT (18.5 {+-} 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 {+-} 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA. (orig.)

  16. Assesment of placement of the esophageal self-expandable metallic stent in esophageal cancer in patients with or without citorreduction therapy Avaliação do emprego de prótese metálica auto-expansível no câncer avançado do esôfago em pacientes com ou sem terapia citorredutora

    Directory of Open Access Journals (Sweden)

    Gilson Kamiyama

    2007-09-01

    Full Text Available BACKGROUND: Placement of self-expanding metallic esophageal stent in patients with advanced esophageal cancer offers excellent palliation of dysphagia and tracheo-esophageal fistulas. However, the safety of stent in patients undergoing radio and/or chemotherapy is controversial, in terms of the greater risk of complications in cases where these two treatments are used in conjunction. AIM: To assess the use of stent in patients with advanced cancer of the mid-thoracic esophagus, by comparing patients undergoing cytoreductive therapy with patients who have not undergone this treatment, in relation to improvement in the dysphagia, rate of complications, period of effectiveness and survival time. METHODS: Fifty seven patients were evaluated retrospectively (16 women and 41 men, with an average age 62 years with advanced squamous cell carcinoma of the mid-thoracic esophagus who underwent placement of the Ultraflex™ self-expandable metallic coated stent, at the Gastrointestinal Endoscopy Unit of São Paulo University Medical School between October 1988 and October 2004. Out of the 57 patients, 24 patients received adjuvant cytoreductive therapy, and 33 patients were only treated with the stent placement. RESULTS: After stent placement, there was improvement in dysphagia in both groups; there were no differences in the rate of complications, such as migration, pain, fistula, obstruction and compression of the airways; the period of effectiveness was significantly higher in the group submitted to cytoreductive therapy (average 123 days compared to 63 days, as was the survival time (average of 210 days, compared with 120 days. CONCLUSIONS: Improvement in dysphagia was statistically significant in both groups, irrespective of whether the patient had undergone adjuvant cytoreductive therapy; there were no differences in the rate of complications between the two groups and both the period of effectiveness of the stent treatment and the survival time were

  17. Stent migration during transcatheter management of coarctation of aorta.

    Science.gov (United States)

    Kannan, Bhava R J; Srinivasan, Muthusamy

    2012-02-15

    A 13-year-old girl underwent endovascular stent placement for coarctation of aorta. The fully expanded stent migrated to ascending aorta which could be stabilized, recrimped, and repositioned with a 20-mm goose neck snare. Postdilatation was performed from the left brachial route resulting in a good outcome.

  18. Acute intracerebral haemorrhage complication after carotid artery stenting

    OpenAIRE

    Chiriac A.; Ion Georgiana; Dobrin N.; Poeata I.

    2015-01-01

    Intracranial hemorrhage following carotid artery stenting is a recognized rare complication but with potentially devastating evolution. Reports of acute cerebral hemorrhage injury following internal carotid artery (ICA) angioplasty are few, and usually were discussed in correlation with hyperperfusion syndrome. In this article we present a patient who experienced a fatal ipsilateral basal ganglia hemorrhage within 10 minutes after carotid angioplasty and stent placement

  19. Long term results of kissing stents in the aortic bifurcation

    NARCIS (Netherlands)

    Hinnen, J.W.; Konickx, M.A.; Meerwaldt, Robbert; Kolkert, J.L.P.; van der Palen, Jacobus Adrianus Maria; Huisman, A.B.

    2015-01-01

    BACKGROUND: To evaluate the long-term outcome after aortoiliac kissing stent placement and to analyze variables, which potentially influence the outcome of endovascular reconstruction of the aortic bifurcation. METHODS: All patients treated with aortoiliac kissing stents at our institution between

  20. Drug-eluting stents in renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M. [Marienhospital Stuttgart, Department of Radiology, Stuttgart (Germany); Pattynama, P.M.T. [Erasmus MC-University Medical Center Rotterdam, Rotterdam (Netherlands); Talen, A. [genae associates nv, Antwerp (Belgium); Sapoval, M. [Hopital Europeen Georges Pompidou, Service de Radiologie Cardio-Vasculaire, Paris (France); Inserm U 780 epidemiologie Cardio Vasculaire, Paris (France)

    2008-04-15

    Because of higher acute and long-term success rates compared with balloon angioplasty alone, percutaneous stent implantation has become an accepted therapy for the treatment of atherosclerotic renal artery stenosis. Restenosis rates after successful renal stent placement vary from 6 up to 40%, depending on the definition of restenosis, the diameter of the treated vessel segment and comorbidities. The safety and efficacy of drug-eluting stents for the treatment of renal-artery stenosis is poorly defined. The recently published GREAT study is the only prospective study, comparing bare-metal and sirolimus-coated low profile stent systems in renal artery stenosis, showing a relative risk reduction of angiographic binary in-stent restenosis by 50%. This is an opinion paper on indications, current treatment options and restenosis rates following renal artery stenting and the potential use of drug-eluting stents for this indication. (orig.)

  1. A long-forgotten indwelling single-J stent in a transplant kidney.

    Science.gov (United States)

    Lai, Dehui; He, Yongzhong; Dai, Yuping; Li, Tian; Chen, Meiling; Li, Xun

    2014-05-01

    Ureteral stent placement is usual after renal transplantation to avoid ureteral obstruction and facilitate reconstruction. However, stent is prone to infection, encrustation, migration, fragmentation, obstruction, and even obstructive nephropathy with a long-indwelling time. Forgotten ureteric stent in renal transplant recipients is scarcely reported. Here, we present a case of long-forgotten indwelling single-J stent for 5 years in a transplant patient.

  2. Stent explantation from an arteriovenous fistula for hemodialysis: a case report.

    Science.gov (United States)

    Nano, Giovanni; Dalainas, Ilias; Casana, Renato; Bianchi, Paolo; Lupattelli, Tommaso; Malacrida, Giovanni; Tealdi, Domenico G

    2006-01-01

    Percutaneous transluminal angioplasty is the first treatment of a dysfunctional vascular access for hemodialysis. A case of stenting of a native arteriovenous hemodialysis fistula is reported that was treated with a stent placement at the anastomosis level, with explantation of the stent after complete thrombosis of the fistula 48 hours after the procedure. It is preferable to treat arteriovenous fistulas with simple balloon dilatation, avoiding stenting of the fistula, especially in the anastomosis site.

  3. 直肠癌及腹膜后肿瘤术中输尿管支架置入预防泌尿系并发症%Cystoscopic Ureteral Stent Placement the Prevention of Urinary Complications After Operation of Rectal Cancer and Retroperitoneal Tumor

    Institute of Scientific and Technical Information of China (English)

    曹广鑫; 王小林; 黄健; 江晓晖

    2014-01-01

    目的:探讨在高手术难度直肠癌及腹膜后肿瘤术中联合膀胱镜下输尿管支架置入预防泌尿系并发症的临床价值。方法9例高手术难度直肠癌及腹膜后肿瘤患者手术前均在膀胱镜下行单侧或双侧输尿管支架置入,复发性直肠癌、新辅助放化疗后直肠癌、后腹膜肿瘤均行R0或R1切除,晚期直肠癌伴梗阻行R2切除。术后3个月门诊膀胱镜下取出支架。结果术中均未发生输尿管切断、损伤、误扎,膀胱损伤,术后均未发生尿瘘、输尿管狭窄等并发症。结论高手术难度直肠癌及腹膜后肿瘤术中先行膀胱镜下输尿管支架置入简单易行,且对于预防泌尿系并发症有重要意义。%Objective To investigate the clinical value of intraoperative cystoscopic ureteral stent placement in the prevention of urinary complications of rectal cancer and retroperitoneal tumor treated with high difficulty opera-tion. Methods Nine cases of rectal carcinoma and retroperitoneal tumor treated with high difficulty operation re-ceived the intraoperative cystoscopic ureteral stent placement,recurrent rectal cancer,rectal cancer after neoadjuvant chemoradiotherapy and retroperitoneal tumor were executed the R0 or R1 resection,advanced rectal cancer with intes-tinal obstruction were executed the R2 resection. Cystoscopic ureteral stent was taken out in the three months after operation. Results There was no ureteral injury and bladder injury in operation,there was no urinary fistula and u-reteral stricture after operation. Conclusion Cystoscopic ureteral stent placement was simple and easy,can be used in the prevention of urinary complications rectal cancer and retroperitoneal tumor treated with high difficulty opera-tion.

  4. Complications and the management of fully covered retrievable metal stent placement in benign tracheal stenosis%可回收全覆膜金属支架治疗良性气管狭窄的并发症及处理

    Institute of Scientific and Technical Information of China (English)

    王征宇; 王永利; 陈光利; 梁熙虹; 王振常; 马建中; 吴广忠; 张效平

    2012-01-01

    Objective To study complications and the management of the use of covered retrievable expandable metallic stents in the treatment of benign tracheal stenosis.Methods Fully covered retrievable metal stents were placed in 21 patients with benign tracheal stenosis.Stent-related complications and the management were reviewed and analysised.Results Twenty-eight fully covered retrievable metallic stents were successfully placed fluoroscopically in 21 patients.Stents were removed 4-12 months [mean (5.5 ±2.2) mouths] after placement in all patients.Stent-related complications included granulation tissue (n =18),stent migration (n =4),stent expectoration (n =2),halitosis (n =8),mucous retention (n =21)and mucus plugging(n =1).Granulation tissue was removed with a carbon dioxide laser in 2 patients.Stents were replaced for 2 times and 3 times respectively in 2 patients after stent migration and stent expectoration.An additional stent was placed in 2 patients after stent migration.Symptom of halitosis was relieved after prolonged course of systemic antibiotics treatment in 8 patients.Symptom of mucous retention was relieved with nebulized saline and N-acetylcysteine saline inhalation.Mucous plug was expelled after severe coughing after suctioning using an aspirator in one patient.There were statistically significant differences in stricture diameter,rank of tachypnea and pulmonary function (FEV1) in all 21 patients before stent insertion and after stents removal.No patient has experienced recurrence during the follow-up period of 1-36 months [mean (23.2 ± 8.0) months].Conclusion Fully covered retrievable metallic stent may be a safe and effective in benign tracheal stenosis.Stent-related complications may be effectively managed.%目的 探讨可回收全覆膜金属支架治疗良性气管狭窄的并发症及处理方法.方法 可回收全覆膜金属支架治疗良性气管狭窄患者21例,其中男18例,女3例,年龄16~ 65岁,平均年龄(33±15)岁,回顾总结分

  5. Extraction of a migrated coil from the Enterprise stent strut using a Solitaire AB stent.

    Science.gov (United States)

    Ge, Huijian; Jin, Hengwei; Li, Youxiang; Lv, Xianli

    2016-12-01

    A 56-year-old woman was admitted to stent-assisted coiling for a 2-mm A1 aneurysm of the left anterior cerebral artery and a left 3-mm internal carotid artery aneurysm. While coiling the A1 aneurysm, the first 2 mm × 20 mm coil migrated through the 4.5 mm × 37 mm Enterprise stent struts, lodging at the distal anterior cerebral artery. A 4 mm × 15 mm Solitaire AB stent was used successfully in this case to remove the displaced coil. The A1 aneurysm was re-treated with a 2 mm × 40 mm coil after placement of the Enterprise stent, and the ophthalmic ICA aneurysm was also coiled through the stent struts. The patient was neurologically intact after treatment. © The Author(s) 2016.

  6. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine . 10th ... Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of ...

  7. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine . 10th ... Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of ...

  8. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... 2010;376(9746):1028-1031. PMID: 20870079 www.ncbi.nlm.nih.gov/pubmed/20870079 . Brott TG, Halperin ... 2013;81(1)E76-E123. PMID: 23281092 www.ncbi.nlm.nih.gov/pubmed/23281092 . Brott TG, Hobson ...

  9. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... AHA/AANN/AANS/ACR/ASNR/CNS/SAIP/SCAI/SIR/SNIS/SVM/SVS guideline on the management of ... Interventions, Society of Interventional Radiology, Society of NeuroInterventional Surgery, Society for Vascular Medicine, and Society for Vascular ...

  10. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    Science.gov (United States)

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT.

  11. Percutaneous Biliary Drainage Using Open Cell Stents for Malignant Biliary Hilar Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sun Jun; Bae, Jae Ik; Han, Tae Sun; Won, Je Hwan; Kim, Ji Dae; Kwack, Kyu Sung; Lee, Jae Hee; Kim, Young Chul [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2012-11-15

    To evaluate the feasibility, safety and the effectiveness of the complex assembly of open cell nitinol stents for biliary hilar malignancy. During the 10 month period between January and October 2007, 26 consecutive patients with malignant biliary hilar obstruction underwent percutaneous insertion of open cell design nitinol stents. Four types of stent placement methods were used according to the patients' ductal anatomy of the hilum. We evaluated the technical feasibility of stent placement, complications, patient survival, and the duration of stent patency. Bilobar biliary stent placement was conducted in 26 patients with malignant biliary obstruction-T (n = 9), Y (n 7), crisscross (n = 6) and multiple intersecting types (n = 4). Primary technical success was obtained in 24 of 26 (93%) patients. The crushing of the 1st stent during insertion of the 2nd stent occurred in two cases. Major complications occurred in 2 of 26 patients (7.7%). One case of active bleeding from hepatic segmental artery and one case of sepsis after procedure occurred. Clinical success was achieved in 21 of 24 (87.5%) patients, who were followed for a mean of 141.5 days (range 25-354 days). The mean primary stent patency period was 191.8 days and the mean patient survival period was 299 days. Applying an open cell stent in the biliary system is feasible, and can be effective, especially in multiple intersecting stent insertions in the hepatic hilum.

  12. Clinical Effect Observation of Endoscopic Metal Stent Implantation for the Treatment of Low Colorectal Cancer with Obstruction%经内镜金属支架植入术治疗低位结直肠癌并梗阻的临床效果观察

    Institute of Scientific and Technical Information of China (English)

    张文凯; 房修椢

    2015-01-01

    Objective Toretrospectively analyze the effect of endoscopic metal stent implantation for the treatment of low colorectal cancer with obstruction. Methods From March,2007 to February 2014,121 patients with low colorectal cancer with obstruction were selected as the objects in two hospitals. 69 cases were given endoscopic metal stent implantation,52 cases were given emergency surgery. The hospitalization time,intestinal function recovery time and the incidence of complications were retrospective analyzed. Results For the patients with endoscopic metal stent implantation,the hospitalization time was 15.4±2.2 days,the intestinal function recovery time was 47.2±3.1 and complication rate was 7.25%. They were superior to emergency surgery group,P<0.05,the differences were statistical y significant. Conclusion Endoscopic metal stent implantation for the treatment of low colorectal cancer with obstruction can effectively improve the quality of life of patients and effectively al eviate the patient's mental anguish. Its clinical effects were significant.%目的:回顾分析经内镜金属支架植入术治疗低位结直肠癌并梗阻的临床效果。方法随机选择两家医院2007年3月至2014年2月收治的121例低位直肠癌合并肠梗阻患者为研究对象,其中经内镜金属支架植入术69例,急诊行手术治疗52例。回顾性分析两组患者的住院时间,肠道功能恢复时间以及并发症发生率。结果经内镜金属支架植入术治疗组患者住院时为(15.4±2.2)天,肠道功能恢复时间为(47.2±3.1)天以及并发症发生率为7.25%明显优于急诊手术治疗组,差异具有统计学意义。结论内镜支架治疗低位结直肠癌致急性梗阻,能够有效改善患者的生存质量,能够有效减轻病人的精神痛苦,临床效果显著。

  13. Percutaneous antegrade ureteric stent removal using a rigid alligator forceps.

    LENUS (Irish Health Repository)

    Given, M F

    2008-12-01

    To evaluate the safety and efficacy of percutaneous antegrade ureteric stent removal using a rigid alligator forceps. Twenty patients were included in our study. Indications for ureteric stent insertion included stone disease (n = 7), malignancy (n = 8) and transplant anastomotic strictures (n = 5). Stent retrieval was carried out for proximal stent placement\\/migration in seven patients and encrustation in the remaining 13. Twenty-two stents were successfully retrieved in 20 patients. There was one technical failure (5%). There were no major complications. We had four minor complications, which included nephrostomy site pain (n = 2), periprocedural sepsis (n = 1) and a small urinoma (n = 1). All patients settled with conservative management. Percutaneous radiologically guided antegrade ureteric stent removal with an alligator forceps is safe and effective, particularly when initial surgical removal has failed.

  14. Stenting for restenotic lesions with the BARD XT stent.

    Science.gov (United States)

    Rahel, Braim M; Suttorp, Maarten J; Te Riele, Hans A; Bal, Egbert T; Ernst, Sjef M; Mast, E Gijs; Ten Berg, Jurriën M; Kelder, Johannes C; Plokker, H W Thijs

    2003-06-01

    Conventional PTCA for the treatment of restenotic lesions is associated with a high rate of recurrence (30-50%). Primary stenting decreases the restenosis rate at long-term follow-up. One-hundred consecutive patients with restenosis received a Bard XT stent. Follow-up angiography was performed after 6 months. Angiograms were compared by means of computed quantitative analysis. The mean pretreatment reference diameter was 2.88 +/- 0.51 mm. The mean minimal luminal diameter (MLD) increased from 1.09 +/- 0.57 mm to 2.70 +/- 0.44 mm. The percent diameter stenosis decreased from 66 +/- 13% to 15 +/- 10%. The procedural success rate was 99%. At 6 month follow-up repeat angiography was performed in 86 patients. The mean MLD was 1.74 +/- 0.67 mm with a mean diameter stenosis of 41 +/- 20%. Residual anginal complaints were reported in 29% of patients. In-stent restenosis (defined as diameter stenosis of more than 50%) occurred in 18% of the patients. Placement of the Bard XT stent in restenotic lesions is feasible, has an excellent short term outcome and yields a favorable result at 6 month follow-up angiography.

  15. ENDOSCOPIC STENT FOR PALLIATING MALIGNANT AND BENIGN BILIARY OBSTRUCTION

    Institute of Scientific and Technical Information of China (English)

    缪林; 范志宁; 季国忠; 文卫; 蒋国斌; 吴萍; 刘政; 黄光明

    2004-01-01

    Objective: To study the techniques of placement of memory alloy plating gold biliary stent and plastic stent for palliation of malignant and benign biliary obstruction, and to assess its clinical effectiveness. Methods: The patients in plastic stent group included paplilla of duodenum inflamational strictures (n=24), common bile duct inflammational inferior segment strictures (n=4), choledocholithiasis (n=5), bile leak (n=11), bile duct surgery injurey (n=7) and pancreatic carcinoma (n=1). The patients in plating gold stent group included common bile duct carcinoma (n=5) and pancreatic carcinoma (n=6). Under fluoroscopic guidance the stent was inserted into biliary obstruction sites from oral cavity in all cases. Complications, liver function and blood serum amylase were investigated during the study period. Results: Successful stent placement was achieved in all cases. After operation of 7 days, in gold biliary stent groups, the rates of decrease of blood serum total bilirubin, glutamic-pyruvic transaminase, r-glutamyl transpeptidase and alkaline phosphatase were 67.16%, 58.37%, 40.63% and 41.54% respectively. In plastic stent group, the rates of decrease of STB, ALT, r-GT and AKP were 53.24%, 55.03%, 37.15%, 34.12% respectively. Early complication included post-ERCP pancreatitis and cholangititis. Occlusion of stent was the major late complication. Conclusion: Memory alloy plating gold biliary stent and plastic stent were safe and efficacious methods for malignant and benign biliary obstruction, and could improve patient's living quality. Plastic stent was an efficient complement for therapy of bile leak and bile duct injury.

  16. Symptomatic stent cast.

    Science.gov (United States)

    Keohane, John; Moore, Michael; O'Mahony, Seamus; Crosbie, Orla

    2008-02-01

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  17. Symptomatic stent cast.

    LENUS (Irish Health Repository)

    Keohane, John

    2012-02-03

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  18. Insertion of self-expanding metal stent for treatment of malignant obstruction in a pregnant woman

    Directory of Open Access Journals (Sweden)

    Noelia Alonso-Lázaro

    2014-03-01

    Full Text Available Colorectal cancer (CRC is the second most frequent cancer both in incidence and mortality in women, especially in those over 60 years of age. Diagnosis in women at gestational age is rare, so its incidence during pregnancy is low. However, an increase in its diagnosis is expected during the next years because of the raise in the average age of pregnancy. In most cases, the diagnosis is delayed because symptoms related to CRC can be attributed to pregnancy itself. Up to 30 % of CRC cases may present as an intestinal obstruction. In this situation, the main objective is to solve the clinical emergency in the safest way for mother and fetus, together with performing an accurate diagnostic approach to offer the best possible therapeutic management knowing the limitations and difficulties related to pregnancy. The self-expanding metallic stent (SEMS can be particularly useful in colon obstruction in a pregnant patient with CRC because it allows solving the acute condition providing time to perform a more accurate staging study and to prepare the patient for surgery, thus reducing both post-surgical morbidity and mortality. We report on the case of a patient who early in the second trimester of pregnancy presented with an acute colonic obstruction due to CRC which was successfully managed with the placement of a self-expanding metal stent.

  19. Efficacy of antiplatelet aggregation drugs in in-stent restenosis after intra-or extra-cerebral stent placement: evaluation by thrombelastogramy%血栓弹力图评价抗血小板药物疗效对颅内外动脉支架术后再狭窄的影响

    Institute of Scientific and Technical Information of China (English)

    李敏; 刘玲; 葛良; 蓝文雅; 侯华娟; 林颖; 杨昉; 刘亚红

    2013-01-01

    angioplasty and stenting (PTAS) by using thromboelastography (TEG) to assess the inhibitory rates of platelet aggregation. Methods Clinical data of 49 patients who were rehospitalizated in 6 to 12 months after PTAS for conventional re-evaluation by digital subtraction angiography (DSA) and TEG, and 6 patients with recurrent ischemic stroke (infarction or transient) after intra-or extra-cerebral stent placement in Jinling Hospital in November 2010 to May 2012 were collected. All patients were assessed the inhibitory rates of arachidonic acid (AA) pathway and adenosine diphosphate (ADP) receptor pathway in platelets by TEG DSA confirmed 14 ISR among 64 lesion vessels treated with stents (ISR group). Potential variables for restenosis and the inhibitory rates of AA pathway and ADP receptor pathway in platelets were analyzed for any predictive power for the ISR with SPSS version 15.0. Results (1) There was significant difference in male-to-female ratio between recurrent stroke group (male/female : 1/5) and non-recurrence group (male/female: 39/4; P 0.05). (2) Compared with non-ISR (control) group, variables in ISR group including age [(58.0 ?12.8) vs (64.6 ?9.8) years], the ratio of diabetes, and the ratio of lesion distributions in intra-and extra-cranial vessels (6/14 vs 7/14, 7/50 vs 43/50) were all significantly different (P < 0.05). Moreover, the serum concentration of hs-CRP was remarkably higher in ISR group than in non-ISR group [(6.1 ?7.6) vs (2.1 ?2.1) mg/L, P = 0.028]. Additionally, inhibitory rates of AA pathway and ADP receptor in patients with ISR were (58.0 ?3.8)% and (28.1 ?6.1)% whereas those in patients without ISR were (83.4 ?23.1)% and (52.8 ?29.5)% respectively, with significant difference (P < 0.01). (3) Logistic regression analysis showed that the inhibitory rate of ADP receptor or efficacy of clopidogrel (HR = 0.959; 95% CI 0.921 ~0.998; P= 0.039) was the only independent negative predictor for ISR after adjustment of the influence of other variables

  20. Product placement

    OpenAIRE

    Šafaříková, Kateřina

    2008-01-01

    The bachelor thesis deals with the product placement and its application in television production. The aim is to assess application of product placement in area European Union and United States of America on particular TV programmes and to enter the question which companies most frequently use product placement in TV production. The theoretical part of the thesis is focused on defining and determination of particular instruments of communication mix. In the practical part is compared legislat...

  1. Placement of a covered self-expandable nitinol stent for bile duct stricture that caused by ischemic injury after transcatheter arterial chemoembolization in a patient with hepatocellular carcinoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Kweon; Seo, Tae Seok; Cha, In Ho; Huh, Sik; Byun, Kwan Soo [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2008-10-15

    The authors report here on a case of focal stricture in the common hepatic duct that was caused by ischemic bile duct injury after repeat TACE procedures for hepatocellular carcinoma, and the patient was successfully treated with a covered self-expandable nitinol stent.

  2. Complications and management of forgotten long-term biliary stents.

    Science.gov (United States)

    Sohn, Se Hoon; Park, Jae Hyun; Kim, Kook Hyun; Kim, Tae Nyeun

    2017-01-28

    To evaluate complications and management outcomes of retained long-term plastic biliary stents. Endoscopic plastic biliary stent placement was performed in 802 patients at Yeungnam University Hospital between January 2000 and December 2014. Follow-up loss with a subsequently forgotten stent for more than 12 mo occurred in 38 patients. We retrospectively examined the cause of biliary stent insertion, status of stents, complications associated with biliary stents and management outcomes of long-term plastic biliary stents. Continuous variables were analyzed using the t test. Observed frequencies in subsets of the study population were compared using Fisher's exact test and χ(2) tests. Statistical significance was defined as P < 0.05 (two-tailed). Mean age of patients was 73.7 ± 12 years and male-to-female ratio was 2.2:1. Indications of plastic biliary stent insertion were bile duct stones (63.2%, 24/38) and benign bile duct stricture (52.6%, 20/38). Mean duration of retained plastic stent was 22.6 ± 12.2 mo, and in 10 cases (26.3%), stents were retained for more than 24 mo. Common bile duct (CBD) stones or sludge were found in most cases (92.1%, 35/38). The most common complication was acute cholangitis (94.7%, 36/38). Stent removal by endoscopic approach was successfully performed in 92.1% (35/38) of the cases. In 3 cases, an additional plastic stent was inserted alongside the previous stent due to failure of the stent removal. Endoscopic removal of bile duct stones was successful in 73.7% (28/38) of the cases. When patients were divided into two groups by duration of stent placement (12 to 24 mo vs over 24 mo), there were no differences in the development of cholangitis, presence of biliary stones, and success rate of endoscopic removal of stones and biliary stents. The most common complication of retained long-term plastic biliary stents was acute cholangitis associated with CBD stones. Endoscopic management was successfully performed in most cases.

  3. 裸支架腔内血管重建术治疗孤立性肠系膜上动脉夹层动脉瘤%Percutaneous endovascular reconstruction with endovascular stent placement for isolated spontaneous dissection of the superior mesenteric artery

    Institute of Scientific and Technical Information of China (English)

    苏浩波; 顾建平; 楼文胜; 何旭; 陈亮; 陈国平; 宋进华; 汪涛; 徐克

    2011-01-01

    目的 评价裸支架载瘤动脉腔内血管重建术治疗孤立性肠系膜上动脉夹层的安全性和疗效.方法 2007年至2010年对5例经腹部CT血管成像(CTA)及数字减影血管造影(DSA)明确诊断的肠系膜上动脉夹层动脉瘤患者行裸支架载瘤动脉腔内血管重建术治疗.按照Sakamoto血管影像学分型,Ⅰ、Ⅱ型各1例,Ⅲ型3例.患者术后继续给予抗凝、抗血小板治疗,术后1、3、6个月进行CTA或血管造影随访.结果 5例患者手术均获成功,其中支架联合弹簧圈栓塞2例,双支架重叠技术3例,无并发症发生.4例症状性患者术后3周内症状消失.5例患者术后3 ~ 6个月时肠系膜上动脉CTA及DSA显示动脉瘤腔不显影,支架腔内血流通畅.随访3 ~ 12个月(平均7.8个月)夹层动脉瘤无复发.结论 裸支架载瘤动脉腔内血管重建术是治疗孤立性肠系膜上动脉夹层安全、有效的方法.%Objective To evaluate the safely arid efficacy of percutaneous endovaseular reconstruction with endovaseular slent placement for Isolated spontaneous dissection of the superior mesenteric artery. Methods Five patients with Isolated spontaneous dissection of the superior mesenteric artery were enrolled in tliis study. The diagnosis was confirmed by abdominal computed tomography auglography (CTA ) and percutaneous transcatheter digital subtraction angiography (DSA ) in all the five patients. One asymptomatic case was discovered by medical examination, which was classified to type I (Sakamoto angiographic categorization). The other four cases were admitted to hospital with acute abdominal pain and diarrhea, which were classified to type JI( 1 case ) and type UK 3 cases). Fasting together with antiplatelet and antieoagulation therapy was initially employed. Then, percutaneous endovaseular reconstruction with stenting was carried out and the patients were kept on antiplatelet therapy. Follow-up checkups with CTA or DSA were conducted at 1. 3 and 6

  4. Lesion load in unprotected carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Papanagiotou, P.; Roth, C.; Karp, K.; Krick, C.; Schieber, H.; Mueller, M.; Reith, W. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Fassbender, K.; Haass, A. [University of the Saarland, Division of Neurology, Homburg (Germany)

    2009-05-15

    The purpose of the study was to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after unprotected carotid artery stent placement. We retrospectively reviewed a nonrandomized cohort of 197 patients presenting with carotid occlusive disease who underwent unprotected carotid artery stent placement between 2003 and 2006. Mean degree of stenosis was 86.94% {+-} 9.72. In all patients, DWI was obtained before and 24 h after stent placement. New lesions were evaluated according to size and location. In 59 of 197 patients (29.9%), new ischemic lesions were found on DWI in the vessel dependent area. In 23 of 197 patients (11.7%), new ischemic lesions were found in the vessel independent area. Combined stroke/death rate was 3.63%. In our series of unprotected carotid angioplasty with stent, we found new DWI lesions in 34% of the patients. Further studies should now show in how far protection devices can reduce these lesions. (orig.)

  5. Silver-nanoparticle-coated biliary stent inhibits bacterial adhesion in bacterial cholangitis in swine

    Institute of Scientific and Technical Information of China (English)

    Wei Wen; Li-Mei Ma; Wei He; Xiao-Wei Tang; Yin Zhang; Xiang Wang; Li Liu; Zhi-Ning Fan

    2016-01-01

    BACKGROUND: One of the major limitations of biliary stents is the stent occlusion, which is closely related to the over-growth of bacteria. This study aimed to evaluate the feasibility of a novel silver-nanoparticle-coated polyurethane (Ag/PU) stent in bacterial cholangitis model in swine. METHODS: Ag/PU was designed by coating silver nanopar-ticles on polyurethane (PU) stent. Twenty-four healthy pigs with bacterial cholangitis using Ag/PU and PU stents were ran-domly divided into an Ag/PU stent group (n=12) and a PU stent group (n=12), respectively. The stents were inserted by standard endoscopic retrograde cholangiopancreatography. Laboratory assay was performed for white blood cell (WBC) count, alanine aminotransferase (ALT), interleukin-1β (IL-1β), tumor necrosis factor-α (TNF-α) at baseline time, 8 hours, 1, 2, 3, and 7 days after stent placements. The segment of bile duct containing the stent was examined histologically ex vivo. Implanted bili-ary stents were examined by a scan electron microscope. The amount of silver release was also measured in vitro. RESULTS: The number of inflammatory cells and level of ALT, IL-1β and TNF-α were significantly lower in the Ag/PU stent group than in the PU stent group. Hyperplasia of the mucosa was more severe in the PU stent group than in the Ag/PU stent group. In contrast to the biofilm of bacteria on the PU stent, fewer bacteria adhered to the Ag/PU stent. CONCLUSIONS: PU biliary stents modified with silver nanoparticles are able to alleviate the inflammation of pigs with bacterial cholangitis. Silver-nanoparticle-coated stents are resistant to bacterial adhesion.

  6. Combination therapy of temporary tracheal stenting and radiofrequency ablation for multinodular thyroid goiter with airway compression

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Beak, Jung Hwan; Oh, Yeon Mok; Ha, Eun Ju; Lee, Jeong Hyun [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2013-10-15

    We report a case of multinodular thyroid goiter in an 80-year-old man who successfully underwent tracheal stent placement for respiratory distress caused by the thyroid goiter and following two radiofrequency (RF) ablation sessions performed for thyroid volume reduction. This sequential treatment allowed elective stent removals four weeks after the second RF ablation session because the thyroid volume had been progressively reduced. Combination therapy of temporary airway stenting and RF ablation for the treatment of thyroid goiter has two advantages, i.e., immediate reliefs of dyspnea with airway stenting and reductions of the thyroid volume with RF ablation, and thus, allowing symptom reliefs even after the stent removals.

  7. Clinical Application of Stents in Digestive Diseases

    Institute of Scientific and Technical Information of China (English)

    GUAN Yongsong

    2002-01-01

    Objective To evaluate clinical application of therapeutic stenting of digestive diseases as a new approach from conventional management. Methods 115 cases of disorders in digestive system were managed with stents clinically, 148 procedures of intervention in all. The cases were suffering from portal hypertension of cirrhosis, post - operative esophageal stricture, Stricture resulted from esophageal carcinoma, Buddi - Chari syndrome, narrowing of superior mesentery arteries and biliary tract, etc. All had had the strictured or obliterated original natural tube lumen been dilated or recanalized under the guidance of monitoring of the fluoroscope before the stent placement except those receiving TIPS needing the creation of an artificial passage within the liver to place the stent. Results Therapeutic stenting achieves clinical effects completely different from conventional internal medicine and surgery such as portal hypertension by cirrhosis with esophageal varices, megalospleen, ascites improved; jaundis relived then resided and liver function improved and appetite better in postoperative stricture of bile duct; ascites and edema of lower limbs resided in Buddi - Chari syndrom; intestininal distention disappeared, appetite and digestive function improved in stricture in superior mesentery artery; and no dysphagia and easy food intake, appetite improved in patients of stricture of postoperative esophagus and stricture resulted from esophageal carcinoma. Conclusion Therapeutic stenting is clinically unique, dramatically effective, with minor risks and worthy promoting in the management of certain digestive disorders.

  8. Outcomes of Self-Expanding Metal Stents in Malignant Colonic Obstruction are Independent of Location or Length of the Stenosis: Results of a Retrospective, Single-Center Series.

    Science.gov (United States)

    Schoonbeek, Paul K; Genzel, Pim; van den Berg, Eline H; van Dobbenburgh, O Aart; Ter Borg, Frank

    2017-08-16

    To evaluate the length and location of stenosis in the colon as predictors of technical and clinical outcomes of stent placement in patients presenting with obstructive colorectal cancer. A prospective single-center cohort study of patients treated with a colonic stent for malignant obstruction, regardless of stenosis length or location. Stenosis length was assessed globally on the appropriate CT slice as well as by 3D CT reconstruction. We analyzed whether outcomes were different in patients with a right sided-tumor and/or a stenosis >4 cm long. One hundred forty-one patients were evaluated, 63 with a stenosis >4 cm, 48 with a stenosis proximal to the splenic flexure. Technical failure (n = 9) was mainly caused because of looping or due to the difficulty in engaging the stenosis precluding analysis of the relation between the stenosis length and technical success. Both measurement methods showed good agreement. Clinical outcomes were not associated with stenosis length or location. Clinical outcomes of stenting did not differ between groups regardless of stenosis length or location. Measuring stenosis length more precisely using 3D CT reconstructions is not of help. © 2017 S. Karger AG, Basel.

  9. [The application of Y-shaped self-expandable covered metal stents in the thoracostomach-airway fistula: a single center, 11 years experience].

    Science.gov (United States)

    Fang, Yi; Li, Tengfei; Han, Xinwei; Wu, Gang; Ren, Jianzhuang; Ren, Kewei; Lu, Huibin; Zhang, Quanhui; Li, Zongming

    2015-08-01

    To investigate the clinical feasibility and efficacy of Y-shaped self-expandable covered metal stents (Y-stents) in the management of thoracostomach-airway fistula. Retrospective analysis was performed for 108 patients treated for thoracostomach-airway fistula with Y-shaped self-expandable coated metal stents between April 2003 and October 2014. Y-stents were designed based on the dimensions of trachea and bronchus and sites of the fistula and then were inserted under DSA monitoring. There were 65 cases with single big Y-stent placement, 26 cases with single small Y-stent placement, 23 cases with double Y-stents placement, and 1 case with 3 Y-stents placement. Stent implantation was successfully accomplished with single manipulation in all patients. Complete occlusion of the fistula was obtained in 104 patients after the primary manipulation, and 4 patients required a secondary manipulation where a double Y-stents was inserted because of failure of primary manipulate. Ninety-two patients completed the follow-up , while 16 were lost. Fifty-nine patients died while 33 were alive with marked improvement in their quality of life. The placement of Y-stents can effectively occlude the thoracostomach-airway fistula in patients who had had the esophageal tumors resected. The technique is not only feasible but reliable to improve the quality of life of the patients.

  10. Renal subcapsular haematoma: an unusual complication of renal artery stenting

    Institute of Scientific and Technical Information of China (English)

    XIA Dan; CHEN Shan-wen; ZHANG Hong-kun; WANG Shuo

    2011-01-01

    After successful renal artery angioplasty and stent placement, a patient in a fully anticoagulated state developed hypotension and flank pain. Computed tomography (CT) of the abdomen revealed a large renal subcapsular haematoma which was successfully managed conservatively without embolotherapy and surgical intervention. To prevent hemorrhage after renal artery stenting, it is necessary to underscore the importance of reducing the contrast volume and pressure of angiography, controlling systemic blood pressure, and monitoring guide wire position at all times.

  11. Acute intracerebral haemorrhage complication after carotid artery stenting

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2015-06-01

    Full Text Available Intracranial hemorrhage following carotid artery stenting is a recognized rare complication but with potentially devastating evolution. Reports of acute cerebral hemorrhage injury following internal carotid artery (ICA angioplasty are few, and usually were discussed in correlation with hyperperfusion syndrome. In this article we present a patient who experienced a fatal ipsilateral basal ganglia hemorrhage within 10 minutes after carotid angioplasty and stent placement

  12. Bronchial stump fistula :treatment with covered retrievable hinged metallic stents-preliminary clinical experience

    Institute of Scientific and Technical Information of China (English)

    LI Yong-dong; HAN Xin-wei; WU Gang; LI Ming-hua

    2007-01-01

    Objective To evaluate the preliminaily clinical efficacy and retrievability of a retrievable hinged covered metallic stent in the treatment of the bronchial stump fistula (BSF). Methods Between April 2003 and March 2005, 8 patients with bronchial stump fistula after pneumonectomy or lobectomy were treated with two types (A and B) of retrievable hinged covered metallic stents. Type A stent was placed in 6 patients and type B in 2 under fluoroscopic guidance. The stent was removed with a retrieval set when BSF was healed or complications occurred. Results Stent placement in the bronchial tree was technically successful in all patients, without procedure-related complications. Immediate closure of the BSF was achieved in all patients after the procedure. Stents were removed from all patients but one. Removal of the stents was difficult in two patients due to tissue hyperplasia. Patients were followed up for 6 - 21 months. Placement of the stents remained stable in all patients except one due to severe cough. Permanent closure of BSF was achieved in 7(87.5%) of 8 patients. Conclusion Use of a retrievable hinged covered expandable metallic stent is a simple,safe, and effective procedure for closure of the BSF. Retrieval of the stent seems to be feasible. (J Intervent Radiol, 2007, 16: 253-257)[ Key words ] Fistula, pulmonary; Bronchialpleural fistula; Stents and prostheses; Computed tomography

  13. VLSI placement

    Energy Technology Data Exchange (ETDEWEB)

    Hojat, S.

    1986-01-01

    The placement problem of assigning modules to module sites in a regular array must be addressed in VLSI and WSI. The placement problem of assigning heterogeneous modules to module sites in a regular array is NP-complete. The placement problem could be simplified if one could find a footprint with the property that all modules of the optimum placement occupy locations in the footprint, with no vacancies within the footprint region. If such footprints were known, they could be precomputed for each system size and the optimization problem would be reduced to a search of placements meeting the footprint constraint. The author shows that the placement problem could not be simplified by finding footprints. As result, several heuristic algorithms for the placement problem were developed and compared to each other and other established algorithms with respect to time complexity and performance measured, by the expected distance traversed by an intermodule message. Compared to previous algorithms, one new heuristic algorithm gave better performance in a shorter execution time on all test examples.

  14. Percutaneous nephrostomy and antegrade ureteral stenting: technique - indications - complications

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, Klaus A. [Klagenfurt General Hospital, Department of Radiology, Klagenfurt (Austria); Portugaller, Horst R. [University Hospital of Graz, Department of Radiology, Graz (Austria)

    2006-09-15

    In this review the technique, indication for and complications of percutaneous nephrostomy (PCN) and antegrade ureter stent insertion are described. In the majority of the cases PCN is performed to relieve urinary obstruction, which can be of benign or malignant nature. Another indication for PCN is for treatment of urinary fistulas. PCN can be performed under ultrasound and/or fluoroscopic guidance, with a success rate of more than 90%. The complication rate is approximately 10% for major and minor complications together and 4-5% for major complications only. Percutaneous antegrade double-J stent insertion usually is performed if retrograde ureter stenting has not been successful. However, especially in malignant obstructions, the success rate for antegrade stenting is higher than for retrograde transvesical double-J stent insertion. In the case of severe infection and bleeding after PCN JJ-stent insertion may be contraindicated so long as there is no sufficient concomitant drainage via a PCN. Lower urinary tract dysfunction should be excluded before stent placement. The complication rate is 2-4%. Consequent stent surveillance with regular stent exchange is mandatory. (orig.)

  15. A RARE CASE OF LARGE VESICAL CALCULUS AROUND A PROL ONGED DOUBLE J STENT: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Sunil Kr.

    2013-04-01

    Full Text Available ABSTRACT: D/J stents constitute an important armamentarium in the hands of an urosurgeon. During short term placement (4-12 weeks, they may c ause flank pain and irritative voiding symptoms, referred to as “stent syndrome.” Complicati ons occur in patients with long term placement of stents who do not come for follow-up - t he forgotten stent. We report a female case with something coming out from external meatus since 2 days with past history of open surgery for right PUJ obstruction with D/J stent in sertion 9 years ago. X-ray KUB & USG abdomen shows a huge vesical calculus around remain ing of the D/J stent. We operated the case with good outcome. This type of rare presentation o f D/J stent motivate us to report this case

  16. Biliary drainage of the common bile duct with an enteral metal stent

    NARCIS (Netherlands)

    dek, I.M.; van den Elzen, B.D.J.; Fockens, P.; Rauws, E.A.J.

    2009-01-01

    In this case report we present an elderly patient who was referred to our hospital with recurrent episodes of cholangitis that persisted after placement of five metal stents for a distal common bile duct (CBD) stenosis. All metal stents were endoscopically removed from the CBD by forceps after

  17. Tracheobronchial Polyflex stents for the management of benign refractory hypopharyngeal strictures

    Institute of Scientific and Technical Information of China (English)

    Rui Almeida Silva; Nuno Mesquita; Pedro Pimentel Nunes; Elisabete Cardoso; Ricardo Marcos Pinto; Luís Moreira Dias

    2012-01-01

    AIM: To describe a modified technique for placement of a tracheobronchial self-expanding plastic stent (SEPS) in patients with benign refractory hypopharyngeal strictures in order to improve dysphagia and allow stricture remodeling.METHODS: A case series of four consecutive patients with complex hypopharyngeal strictures after combined therapy for laryngeal cancer, previously submitted to multiple sessions of dilation without lasting improvement, is presented. All patients underwent placement of a small diameter and unflared tracheobronchial SEPS. Main outcome measurements were improvement of dysphagia and avoiding of repeated dilation.RESULTS: The modified introducer system allowed an easy and technically successful deployment of the tracheobronchial Polyflex stent through the stricture. All four patients developed complications related to stent placement. Two patients had stent migration (one proximal and one distal), two patients developed phan-ryngocutaneous fistulas and all patients with stents in situ for more than 8 wk had hyperplastic tissue growth at the upper end of the stent. Stricture recurrence was observed at 4 wk follow-up after stent removal in all patientsCONCLUSION: Although technically feasible, placement of a tracheobronchial SEPS is associated with a high risk of complications. Small diameter stents must be kept in place for longer than 3 mo to allow adequate time for stricture remodeling.

  18. Two Cases of Carcinoma with Tracheobronchial Stenosis Treated by Self-expanding Nitinol Stents(Sens)

    OpenAIRE

    山本,夏男; 宮下,義啓; 千葉,成宏

    1999-01-01

    Two cases with tracheobronchial stenosis due to tumors(lung and esophageal cancer) were treated by Self-expanding nitinol stent(Ultraflex). Severe dyspnea and stridor were markedly impromed after placement of nitinol stents. Insertion of Ultraflex is easy and useful for prevention and improvement of airway obstruction.

  19. 结直肠金属支架置入术对左半结肠癌所致肠梗阻的治疗价值%Therapeutic value of endoscopic metal stent implantation for left-sided malignant colorectal obstruction

    Institute of Scientific and Technical Information of China (English)

    张杰; 陈婧; 张谨芬; 武沪平; 郝建宇

    2012-01-01

    Objective To investigate the therapeutic value of endoscopic implantation of metal stents for obstruction caused by left-sided malignant colorectal tumor.Methods Data of 29 patients with left-sided malignant colonic obstruction who underwent stenting from May 2007 to May 2011 were retrospectively analyzed.Results Self-expanding metal stents were successfully implanted in 27 patients.Symptoms of abdominal distention and vomiting subsided in these patients.The procedure failed in 2 patients (2/29,6.9% ),because the guidewire failed to pass the colonic stricture due to edema and the length of the diseased colon.Technical success was achieved in 27 of total 29 patients (27/29,92.6% ).Out of the 27 patients,stage Ⅰ primary left-sided colonic resection and anastomosis were successfully performed in 24 patients.Colonic perforation was found intraoperatively in 1 patient ( 1/27,3.7% ) who subsequently recovered after operation.There was no death during the perioperative period with the average hospital stay of 11.7 days.A mean colonic stent patency for 5 months was observed in 3 patients who underwent palliative stenting only.Conclusion Endoscopic implantation of metal stents is effective for left-sided malignant colorectal obstruction.As a bridge to surgery,it facilitates sufficient bowel preparation for elective radical operation.%目的 探讨结直肠金属支架置入术对左半结肠癌所致肠梗阻的治疗价值.方法 对2007年5月至2011年5月因左半结肠癌肠梗阻接受结直肠金属支架置入术的29例患者的病例资料进行回顾性分析.结果 27例成功进行支架置入术,腹胀、呕吐症状缓解,2例由于病变肠段较长,高度水肿,完全阻塞肠腔,导丝无法通过而未成功,支架置入成功率92.6% (27/29).置入支架的27例中24例成功进行了Ⅰ期左半结肠切除无张力吻合术,术中发现支架穿透肠壁1例(1/27,3.7%),手术后好转,围手术期无死亡病例发生,平均住院天数11

  20. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  1. Paradoxical Hypertension after Successful Cheatham Platinum Stent Implantation in an Adolescent with Coarctation of the Aorta

    Science.gov (United States)

    Tan, Yin Ling; Chih, Wan-Ling; Wang, Jou-Kou; Chen, Chun-An

    2016-01-01

    Stent implantation using a Cheatham Platinum (CP) stent for coarctation of the aorta (CoA) is a promising treatment alternative to traditional surgical repair. However, there are no earlier reports in the literature focusing on use of this stent in a Taiwanese patient. Herein we report a 16-year-old boy with CoA presenting with heart murmur and exercise intolerance who underwent successful CP stent placement. However, severe hypertension with arterial blood pressure increasing to 207/104 mmHg occurred four hours after stent implantation. There was no abdominal pain, nausea or vomiting. The patient’s hypertension was controlled by intravenous nitroglycerin infusion, followed by an oral antihypertensitve agent for the following 7 days. Experience from this case highlighted the usefulness of CP stent implantation for native CoA, and the importance of early recognition and management of paradoxical hypertension after CoA stenting. PMID:27899866

  2. Can donated media placements reach intended audiences?

    Science.gov (United States)

    Cooper, Crystale Purvis; Gelb, Cynthia A; Chu, Jennifer; Polonec, Lindsey

    2013-09-01

    Donated media placements for public service announcements (PSAs) can be difficult to secure, and may not always reach intended audiences. Strategies used by the Centers for Disease Control and Prevention's (CDC) Screen for Life: National Colorectal Cancer Action Campaign (SFL) to obtain donated media placements include producing a diverse mix of high-quality PSAs, co-branding with state and tribal health agencies, securing celebrity involvement, monitoring media trends to identify new distribution opportunities, and strategically timing the release of PSAs. To investigate open-ended recall of PSAs promoting colorectal cancer screening, CDC conducted 12 focus groups in three U.S. cities with men and women either nearing age 50 years, when screening is recommended to begin, or aged 50-75 years who were not in compliance with screening guidelines. In most focus groups, multiple participants recalled exposure to PSAs promoting colorectal cancer screening, and most of these individuals reported having seen SFL PSAs on television, in transit stations, or on the sides of public buses. Some participants reported exposure to SFL PSAs without prompting from the moderator, as they explained how they learned about the disease. Several participants reported learning key campaign messages from PSAs, including that colorectal cancer screening should begin at age 50 years and screening can find polyps so they can be removed before becoming cancerous. Donated media placements can reach and educate mass audiences, including millions of U.S. adults who have not been screened appropriately for colorectal cancer.

  3. Direct coronary stent implantation: safety, feasibility, and predictors of success of the strategy of direct coronary stent implantation.

    Science.gov (United States)

    Laarman, G; Muthusamy, T S; Swart, H; Westendorp, I; Kiemeneij, F; Slagboom, T; van der Wieken, R

    2001-04-01

    This prospective study was designed to evaluate the feasibility, safety, predictive factors of success, and 6-month follow-up of stent implantation without balloon predilatation (direct stenting) in 250 patients undergoing elective stent implantation. Balloon dilatation prior to stent implantation was a prerequisite to facilitate passage and deployment of the stent. Stent technology has changed tremendously, resulting in stents with improved properties, which may allow stent placement without prior balloon dilatation. Patients with coronary lesions suitable for elective stent implantation were included in this trial. Coronary interventions were undertaken predominantly via the transradial route using 6 Fr guiding catheters. Direct stent implantation was attempted using AVE GFX II coronary stent delivery systems. Upon failure, predilatation was undertaken before reattempting stent implantation. Patient data and ECGs were obtained from case records and from personal or telephone interviews 6 months after the procedure. Values were presented as mean +/- standard deviation. Student's t-test, two-tailed at 5% level of significance, was used to compare the difference of two means. Multivariate logistic regression analysis was performed to establish predictive factors for failure of direct stenting. Two hundred and sixty-six direct stent implantations were attempted in 250 patients. Direct stenting was successful in 226 (85%) cases. Out of 40(15%) cases where direct stenting failed, balloon predilatation facilitated stent implantation in 39. In one lesion, stent implantation was not possible despite adequate predilatation. Predictive factors for failure of direct stenting on multivariate analysis were LCx lesions (P < 0.01), complex lesions (P < 0.01), and longer stents (P < 0.001). Minimal luminal diameter and percentage diameter stenosis of lesions in the successful and the failure group were not significantly different (0.94 +/- 0.39 mm vs. 0.84 +/- 0.41 mm, P = NS

  4. Efficacy of retrievable metallic stent with fixation string for benign stricture after upper gastrointestinal surgery

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Jeong Eun; KIm, Hyo Cheol; Lee, Myung Su; Hur, Sae Beom; KIm, Minuk; Lee, Sang Hwan; Cho, Soo Buem; KIm, Chan Sun; Han, Joon Koo [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-11-15

    To determine the efficacy of retrievable metallic stent with fixation string for benign anastomotic stricture after upper gastrointestinal (UGI) surgery. From June 2009 to May 2015, a total of 56 retrievable metallic stents with fixation string were placed under fluoroscopy guidance in 42 patients who were diagnosed with benign anastomotic stricture after UGI surgery. Clinical success was defined as achieving normal regular diet (NRD). The clinical success rate after the first stent placement was 57.1% (24/42). After repeated stent placement and/or balloon dilation, the clinical success rate was increased to 83.3% (35/42). Six (14.3%) patients required surgical revision to achieve NRD. One (2.4%) patient failed to achieve NRD. Stent migration occurred in 60.7% (34/56) of patients. Successful rate of removing the stent using fixation string and angiocatheter was 94.6% (53/56). Distal migration occurred in 12 stents. Of the 12 stents, 10 (83.3%) were successfully removed whereas 2 could not be removed. No complication occurred regarding distal migration. Using retrievable metallic stent with a fixation string is a feasible option for managing early benign anastomotic stricture after UGI surgery. It can reduce complications caused by distal migration of the stent.

  5. Self-expanding Metallic Stent Placement for Colonic Stoma Stenosis:Case Report%自扩张金属支架置入治疗结肠造口狭窄1例

    Institute of Scientific and Technical Information of China (English)

    于俊秀; 赵传林; 张彦波; 成红刚

    2016-01-01

    [Summary] In October 2015, a patient presented colonic stoma stenosis after laparoscopic rectal surgery for cancer , which led to intestinal obstruction .After repeated finger dilation therapy which turned to be ineffective , a self-expandable metal stent was implanted in the colonic stoma .The colonic stoma stenosis and intestinal obstruction was relieved on the next day .The stent was removed 3 weeks later .After 3 months of follow-up, no occurrence of colonic stoma stenosis was observed .%2015年10月,1例腹腔镜直肠癌切除术后患者出现结肠造口狭窄导致肠梗阻,多次手指扩张无效后,经结肠造口置入记忆合金网状支架,狭窄及肠梗阻第2天解除,3周后去除支架,随访3个月未见狭窄复发。支架置入术应成为治疗结肠造口狭窄的首选方法。

  6. Clinical observation of the middle-late patients with esophageal cancer to perform esophageal stent placement and radiation therapy%覆膜支架置入联合放射治疗在中晚期食管癌治疗中的临床观察

    Institute of Scientific and Technical Information of China (English)

    胥雄阳; 赵平宗; 蒋丽琳; 杨兴平; 郭凤英; 贾碧慧

    2015-01-01

    Objective To study the clinical value of esophageal stent placement with radiation therapy for the middle-late pa-tients with esophageal cancer.Methods To perform esophageal stent placement and radiation therapy for the middle-late 35 pa-tients,and to perform radiation therapy for the middle-late 37 patients,then observe the clinical curative effects.Results The treat-ment group were significantly alleviated with dysphagia symptom after operation,which 32 cases sticked the entire radiation,ac-counting for 91.4%,no one can′t complete the treatment because of nutritional status reason.Survival time of one month after ra-diotherapy was up to 100.0%,and survival time of six months was 85.7% (30/35).But the contrast group with dysphagia symp-tom were aggravated or no relief,and needed parenteral nutrition.There were 23 cases to complete the entire radiation,accounting for 62.2%,and 5 cases happened esophageal tracheal fistula.Survival time of one month after radiotherapy was 83.8%(31/37),and survival time of six months was 62.2% (23/37).Two groups of cases in radiotherapy resistance difference was statistically signifi-cant,one month and six months of survival time were statistically significant (all P <0.05 ).Conclusion Esophageal stent place-ment with radiotherapy is more efficient than only radiation therapy to the middle-late patients with esophageal cancer.%目的:探讨食管覆膜支架置入联合放射治疗对中晚期食管癌治疗的临床价值。方法对35例中晚期食管癌患者进行覆膜支架置入术并放射治疗(治疗组),对37例中晚期食管癌患者进行单纯放射治疗(对照组),并进行临床疗效对比观察。结果治疗组术后患者吞咽困难症状均明显缓解,坚持完成全程放射治疗32例(91.4%),无因营养状况原因导致治疗情况不能完成;放射治疗后1个月以上生存期达100.0%,6个月生存期为85.7%(30/35)。对照组放射治疗开始1周内吞咽困难症状加重或无缓解,需

  7. What Is Colorectal Cancer?

    Science.gov (United States)

    ... Research? Colorectal Cancer About Colorectal Cancer What Is Colorectal Cancer? Colorectal cancer is a cancer that starts in ... and spread, see What Is Cancer? How does colorectal cancer start? Most colorectal cancers begin as a growth ...

  8. Stent treatment of symptomatic intracranial arterial stenosis

    Directory of Open Access Journals (Sweden)

    DONG Feng-ju

    2012-08-01

    Full Text Available Objective To investigate the safety, feasibility and efficacy of the Wingspan stent in treatment of symptomatic intracranial arterial stenosis. Methods Wingspan stenting was applied in 90 cases with symptomatic intracranial arterial stenosis. The surgical success rate and periprocedural neurological complications were observed. Digital subtraction angiography was performed at 6 months after stenting to detect the occurrence of restenosis. Results The technical success rate was 98.92% (92/93. Pre-treatment stenosis (83.42 ± 9.53% was improved to (21.82 ± 9.86% after stent placement. The difference was statistically significant (t = 3.280, P = 0.002. There were 5 patients (5.56% occurred major periprocedural neurological complications, 3 of them died within 30 days after the procedure. The restenosis rate at 6 months after operation was 19.10% (17/89. Conclusion Symptomatic intracranial arterial stenosis can be treated by Wingspan stenting with high technical success rate. The occurrence of complication is low and short-term efficacy is good. However, further study is needed to investigate long-term effect.

  9. Hemodynamic effects of stenting on wide-necked intracranial aneurysms

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yi-sen; LUO Bin; LI Chuan-hui; YANG Xin-jian; WANG Sheng-zhang; QIAO Ai-ke; CHEN Jia-liang; ZHANG Kun-ya; LIU Zhi-cheng; ZHAO Yu-jing; ZHANG Ying

    2010-01-01

    Background Stent placement has been widely used to assist coiling in cerebral aneurysm treatments. The present study aimed to investigate the hemodynamic effects of stenting on wide-necked intracranial aneurysms.Methods Three idealized plexiglass aneudsmal models with different geometries before and after stenting were created, and their three-dimensional computational models were constructed. Flow dynamics in stented and unstented aneurismal models were studied using in vitro flow visualization and computational fluid dynamics (CFD) simulations. In addition, effects of stenting on flow dynamics in a patient-specific aneurysm model were also analyzed by CFD.Results The results of flow visualization were consistent with those obtained with CFD simulations. Stent deployment reduced vortex inside the aneurysm and its impact on the aneurysm sac, and decreased wall shear stress on the sac.Different aneurysm geometries dictated fundamentally different hemodynamic patterns and outcomes of stenting.Conclusions Stenting across the neck of aneurysms improves local blood flow profiles. This may facilitate thrombus formation in aneurysms and decrease the chance of recanalization.

  10. Stenting in the treatment of acute ischemic stroke: literature review.

    Directory of Open Access Journals (Sweden)

    Edgar A Samaniego

    2011-12-01

    Full Text Available Recanalization of acute large artery occlusions is a strong predictor of good outcome. The development of thrombectomy devices resulted in a significant improvement in recanalization rates compared to thrombolytics alone. However, clinical trials and registries with these thrombectomy devices in acute ischemic stroke (AIS have shown recanalization rates in the range of 40-81%. The last decade has seen the development of nickel titanium self-expandable stents (SES. These stents, in contrast to balloon-mounted stents, allow better navigability and deployment in tortuous vessels and therefore are optimal for the cerebral circulation. SES were initially used for stent-assisted coil embolization of intracranial aneurysms and for treatment of intracranial stenosis. However, a few authors have recently reported feasibility of deployment of SES in AIS. The use of these devices yielded higher recanalization rates compared to traditional thrombectomy devices. Encouraged by these results, retrievable SES systems have been recently used in AIS. These devices offer the advantage of resheathing and retrieving of the stent even after full deployment. Some of these stents can also be detached in case permanent stent placement is needed. Retrievable SES are being used in Europe and currently tested in clinical trials in the United States. We review the recent literature in the use of stents for the treatment of AIS secondary to large vessel occlusion.

  11. Metallic Stents for Tracheobronchial Pathology Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, Carolina, E-mail: carolina.serrano@unizar.es [University of Zaragoza, Surgical Pathology Unit, Animal Pathology Department (Spain); Laborda, Alicia, E-mail: alaborda@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain); Lozano, Juan M., E-mail: juamauloz@gmail.com [Marly Clinic, Radiology Department (Colombia); Caballero, Hugo, E-mail: hugocaballero2007@gmail.com [Marly Clinic, Pulmonology Department (Colombia); Sebastian, Antonio, E-mail: antonio.sebastian@ono.es [Lozano Blesa Clinical University Hospital, Pulmonology Department (Spain); Lopera, Jorge, E-mail: lopera@uthscsa.edu [Health Science Center, Interventional Radiology Deparment (United States); Gregorio, Miguel Angel de, E-mail: mgregori@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain)

    2013-12-15

    Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 {+-} 1.2 months in patients with malignant lesions and 76.2 {+-} 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

  12. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Pausawasadi, Nonthalee [Department of Medicine, Siriraj Hospital, Mahidol University, Bangkok (Thailand); Soontornmanokul, Tanassanee; Rerknimitr, Rungsun [Department of Medicine, Chulalongkorn University, Bangkok (Thailand)

    2012-02-15

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  13. Role of metallic stents in benign esophageal stricture

    Science.gov (United States)

    Shim, Chan Sup

    2012-10-01

    Simple esophageal strictures, which are focal, straight, and large in diameter, usually require 1 - 3 dilation sessions to relieve symptoms. However, complex strictures, which are long, tortuous, or associated with a severely compromised luminal diameter, are usually more difficult to treat with conventional bougie or balloon dilation techniques, and often have high recurrence rates. Although the permanent placement of self-expandable metal stents (SEMS) has been used to manage refractory benign esophageal strictures, this procedure is associated with additional problems, such as stricture from tissue hyperplasia, stent migration, and fistula formation. Thus, several new types of stents have been developed, including temporary SEMS, self-expandable plastic stents (SEPS), and biodegradable stents. The use of these new products has produced varied results. Temporary SEMS that have been used to relieve benign esophageal conditions have caused granulation tissue at both ends of the stent because of contact between the mucosa and the exposed metal components of the stent, thus hindering stent removal. We examined the tissue response to two new types of SEMS, a flange-type and a straighttype, each coated with a silicone membrane on the outside of the metal mesh. These two SEMS were evaluated individually and compared with a conventional control stent in animal experiments. Although the newly designed stents resulted in reduced tissue hyperplasia, and were thus more easily separated from the esophageal tissue, some degree of tissue hyperplasia did occur. We suggest that newly designed DES (drug-eluting stents) may provide an alternative tool to manage refractory benign esophageal stricture.

  14. Chest pain following oesophageal stenting for malignant dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Golder, Mark; Tekkis, Paris P.; Kennedy, Colette; Lath, Sadaf; Toye, Rosemary; Steger, Adrian C

    2001-03-01

    AIM: The palliative use of self-expanding metallic stents has been widely reported to relieve dysphagia in cases of oesophageal carcinoma. Little has been documented on the severity of chest pain following oesophageal stenting. The aim of this study was to investigate the association of pain with oesophageal stenting for malignant dysphagia. METHODS: Fifty-two patients with inoperable oesophageal carcinoma underwent stent placement between 1995-1999. Daily opioid analgesic requirements (mg of morphine equivalent doses) were monitored for 3 days before and 7 days after stenting. The degree of palliation was expressed as a dysphagia score (0-3). Hospital stay, readmission days, stent complications and patient survival time were also recorded. RESULTS: Twenty-six patients (50%) required opioid analgesia for chest pain (median dose: 80 mg morphine/day) within 48 h of the procedure compared to 11 (21.2%) patients before stenting (P = 0.0041). A significant increase was evident in the analgesic consumption following stent deployment (P < 0.001). The dysphagia score improved by a median value of 1 (CI 0.25)P < 0.001, with a re-intervention rate of 11.5%. The median survival time was 40 days post stenting (range 1-120). CONCLUSION: A significant proportion of patients developed chest pain after oesophageal stenting, requiring high dose opioid analgesia. As the origin of the pain is still unknown, pre-emptive analgesia may a play role in reducing stent-related morbidity and possibly in-hospital stay. Golder, M. et al. (2001)

  15. Development of a New Hanging-Type Esophageal Stent for Preventing Migration: A Preliminary Study in an Animal Model of Esophagotracheal Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Masayuki, E-mail: masay010@yahoo.co.jp; Kaminou, Toshio, E-mail: kaminout@med.tottori-u.ac.jp; Ohuchi, Yasufumi, E-mail: oyasu@med.tottori-u.ac.jp [Tottori University, Department of Radiology, Faculty of Medicine (Japan); Sugiura, Kimihiko, E-mail: kimihikosugiura@gmail.com [Yonago Medical Center, Department of Radiology (Japan); Yata, Shinsaku, E-mail: yata-s@med.tottori-u.ac.jp; Adachi, Akira, E-mail: july1st@med.tottori-u.ac.jp; Kawai, Tsuyoshi, E-mail: prgr-xxio@kuc.biglobe.ne.jp; Takasugi, Syohei, E-mail: stakasugi@med.tottori-u.ac.jp; Yamamoto, Shuichi, E-mail: yamamotoshu@med.tottori-u.ac.jp; Matsumoto, Kensuke, E-mail: matsumoto-k@v103.vaio.ne.jp [Tottori University, Department of Radiology, Faculty of Medicine (Japan); Hashimoto, Masayuki, E-mail: hashimotom@pref.tottori.jp [Tottori Prefectural Kosei Hospital, Department of Radiology (Japan); Ihaya, Takashi, E-mail: iahaya@orange.ocn.ne.jp [Sanin Rosai Hospital, Department of Radiology (Japan); Ogawa, Toshihide, E-mail: ogawa@med.tottori-u.ac.jp [Tottori University, Department of Radiology, Faculty of Medicine (Japan)

    2012-10-15

    Purpose: Covered, self-expandable metallic stents (SEMS) have been enthusiastically adopted for the treatment of esophagotracheal fistula, but problems with stent migration have yet to be resolved. To overcome this problem, we have developed a new hanging-type esophageal stent designed to prevent migration, and we conducted an animal study to assess the efficacy of our method. Methods: A total of six female pigs were used in this study. The main characteristic of our stent was the presence of a string tied to the proximal edge of the stent for fixation under the skin of the neck. The first experiment was performed to confirm technical feasibility in three pigs with esophagotracheal fistula. The second experiment was performed to evaluate stent migration and esophagotracheal fistula in three pigs. Results: Creation of the esophagotracheal fistula and stent placement were technically successful in all pigs. In the first experiment, esophagotracheal fistula was sealed by stent placement. In the second experiment, no stent migration was seen 11 or 12 days after stent placement. Gross findings showed no fistulas on the esophageal or tracheal wall. Conclusions: Our new hanging-type esophageal stent seems to offer a feasible method for preventing stent migration.

  16. Prospective analysis of a complete retrograde ureteroscopic technique with holmium laser stent cutting for management of encrusted ureteral stents.

    Science.gov (United States)

    Thomas, Alexandre; Cloutier, Jonathan; Villa, Luca; Letendre, Julien; Ploumidis, Achilles; Traxer, Olivier

    2017-03-14

    To propose and evaluate a new endoscopic technique using only a retrograde ureteroscopic approach for the removal of heavily encrusted ureteral stents. Data from 51 consecutive patients with encrusted and retained ureteral stents were prospectively collected. Description of the successive steps of surgery is detailed. The Holmium-YAG laser properties offer the opportunity for fragmentation of stent-attached encrustation and the ability to cut the stent itself. Reducing the length of the stent is critical to creating space in the ureter and to allow free access for ureteroscopes or ureteral access sheath placement. The primary outcome of this study was the feasibility and the safety of this retrograde intra-renal approach. Some factors of encrustation and outcomes are also discussed in comparison with lithotripsy, percutaneous, laparoscopic, open surgery or a combination of these techniques. The removal of the encrusted stent was possible with only this retrograde technique in 98% of patients. The transection of the encrusted stent with the Holmium-YAG laser was useful in 71% of the patients. Mean operative time was 110 minutes and mean hospital stay was 2.33 days. Postoperative complications were mainly non-obstructive pyelonephritis (10%). The most significant predictor of this life threatened complication was the presence of struvite stones with the encrusted stent (p=0,018). Contrariwise, operative time, BMI, gender and encrustation rate were not associated with postoperative pyelonephritis. Cystine stone disease or pregnancy both led to faster stent encrustation. Retrograde ureteroscopic surgery is efficient and safe for removing retained stents and associated stone burdens. The Holmium-YAG laser is essential to perform the encrustation removal and sectioning of the stent.

  17. Emergency treatment of endobronchial stent placement for serious main bronchial stenosis following high-risk orthotopic heart allotransplantation: One case report%高风险原位同种异体心脏移植术后支气管狭窄的急诊支架置入治疗:1例报告

    Institute of Scientific and Technical Information of China (English)

    赵永祥; 欧阳文; 朱岳; 赵玲玲; 单忠贵; 唐琪; 阳玲; 范钦明; 易波; 廖崇先; 周志明

    2007-01-01

    BACKGROUND: Ventilation dysfunction caused by bronchomalacia induced bronchostenosis following high-risk heart transplantation is an acute clinical disease, which seriously impairs the function of transplant heart. The case of emergency bronchial stent placement following heart transplantation with high-risk multi-complication has not been reported yet.OBJECTIVE: To investigate the curative effect of emergency stent placement for worse left main bronchial malacia, stenosis and collapse following orthotopic heart allotransplantation.DESIGN: A case analysis.SETTINGS: National Ministry of Health Transplantation Engineering and Technical Research Center, the Third Xiangya Hospital, Central South University; Department of Cardiosurgery, Zhongshan Hospital affiliated to Xiamen University.PARTICIPANTS: An 18-year-old female patient with dilated cardiomyopathy accompanied by moderate to severe pulmonary artery hypertension, who sequentially carried out orthotopic heart allotransplantation, was selected from the Department of Cardiosurgery, Zhongshan Hospital affiliated to Xiamen University in April, 2004. She had suffered from dilated cardiomyopathy for 15 years, and the mean pulmonary artery pressure (MPAP) was 50-51 mm Hg, she was also accompanied by left main bronchial malacia, stenosis and collapse, mixed (mainly central-) sleep apnea syndrome, left inferior pulmonary sequestration, right emphysema, and rheumatoid arthritis for half a year.METHODS: After heart transplantation, bronchus inflammation, congested edema aggravated the severity of bronchial malacia, stenosis and collapse, tenosis reduced to 4/5, and led to obstructive type of ventilation, and the patient was also accompanied by supraventricular tachycardia, ventricular extrasystole, and hypofunction of transplant cardiac systolic function (peak E<peak A, ejection fraction reduced to 40%, inharmonious motion of ventricular wall). Attempted with inotropic agents and ventilator/support were not relieved

  18. Enteral metallic stenting by balloon enteroscopy for obstruction of surgically reconstructed intestine.

    Science.gov (United States)

    Nakahara, Kazunari; Okuse, Chiaki; Matsumoto, Nobuyuki; Suetani, Keigo; Morita, Ryo; Michikawa, Yosuke; Ozawa, Shun-ichiro; Hosoya, Kosuke; Kobayashi, Shinjiro; Otsubo, Takehito; Itoh, Fumio

    2015-06-28

    We present three cases of self-expandable metallic stent (SEMS) placement using a balloon enteroscope (BE) and its overtube (OT) for malignant obstruction of surgically reconstructed intestine. A BE is effective for the insertion of an endoscope into the deep bowel. However, SEMS placement is impossible through the working channel, because the working channel of BE is too small and too long for the stent device. Therefore, we used a technique in which the BE is inserted as far as the stenotic area; thereafter, the BE is removed, leaving only the OT, and then the stent is placed by inserting the stent device through the OT. In the present three cases, a modification of this technique resulted in the successful placement of the SEMS for obstruction of surgically reconstructed intestine, and the procedures were performed without serious complications. We consider that the present procedure is extremely effective as a palliative treatment for distal bowel stenosis, such as in the surgically reconstructed intestine.

  19. Colorectal Cancer

    Science.gov (United States)

    ... rectum are part of the large intestine. Colorectal cancer occurs when tumors form in the lining of ... men and women. The risk of developing colorectal cancer rises after age 50. You're also more ...

  20. Colonic perforations caused by migrated plastic biliary stents

    Energy Technology Data Exchange (ETDEWEB)

    Virgilio, Edoardo; Pascarella, Agauido; Scandavini, Chiara Maria; Frezza, Barbara; Bocchetti, Tommaso; Balducci, Genoveffa [Faculty of Medicine and Psychology ' Sapienza' , St. Andrea Hospital, Rome (Italy)

    2015-04-15

    Endoscopic insertion of plastic endoprostheses has become an integral part of the management of many benign and malignant diseases affecting the hepatobiliary and pancreatic system. Clogging and dislocation into the duodenum are the most frequently described complications following stent placement. Distal migration with or without perforation of the colon is an exceedingly rare phenomenon and the treatment is not well defined, as discussed below.

  1. Fatal pericardial tamponade after superior vena cava stenting.

    NARCIS (Netherlands)

    Ploegmakers, M.J.M.; Rutten, M.J.C.M.

    2009-01-01

    We discuss a fatal complication of percutaneous superior vena cava (SVC) self-expandable stent placement in a patient with superior vena cava syndrome (SVCS). The SVCS was caused by a malignant mediastinal mass with total occlusion of the SVC. Twenty-four hours after the procedure, the patient died

  2. Fatal pericardial tamponade after superior vena cava stenting.

    NARCIS (Netherlands)

    Ploegmakers, M.J.M.; Rutten, M.J.C.M.

    2009-01-01

    We discuss a fatal complication of percutaneous superior vena cava (SVC) self-expandable stent placement in a patient with superior vena cava syndrome (SVCS). The SVCS was caused by a malignant mediastinal mass with total occlusion of the SVC. Twenty-four hours after the procedure, the patient died

  3. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho [Chonbuk National University Medical School and Hospital, Chonju (Korea, Republic of)

    2007-10-15

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates.

  4. The location of obstruction predicts stent occlusion in malignant gastric outlet obstruction

    Science.gov (United States)

    Grunwald, Douglas; Cohen, Jonah; Bartley, Anthony; Sheridan, Jennifer; Chuttani, Ram; Sawhney, Mandeep S.; Pleskow, Douglas K.; Berzin, Tyler M.; Mizrahi, Meir

    2016-01-01

    Background: Gastric outlet obstruction (GOO) can occur with locally invasive or metastatic cancer involving the upper gastrointestinal tract at the pylorus or the duodenum. Endoscopic management with self-expanding metal stents (SEMSs) is often the preferred palliative approach. Stent occlusion is a common reason for failure and reintervention. We set out to determine whether the location of the malignant obstruction is associated with the angulation of the stent and can predict stent occlusion. Methods: We performed a retrospective review of consecutive patients who underwent successful duodenal stenting with SEMS for malignant GOO between 2006 and 2015 at a large advanced endoscopy referral center. We determined the location of obstruction, the stent angle, and the rate of technical and clinical success of stent placement. We then identified cases of subsequent stent occlusion confirmed by endoscopic evaluation. Results: A total of 100 consecutive patients were included in the study; 91 of these patients had enough data to evaluate SEMS occlusion. A total of 21 patients (23%) developed stent occlusion with a median time of 39 days. The risk of occlusion sequentially increased as the obstruction occurred more distally from the antrum to the third or fourth portion of the duodenum (p = 0.006). This relationship was maintained after controlling for stent angle (p = 0.05). Conclusions: A distal location of malignant GOO was strongly predictive of stent occlusion, independent of stent angle. This may be due to longer and more complex distal obstructions, along with foreshortening of the stent during placement and tumor infiltration. If replicated, these results will have implications for endoscopic practice and future device development. PMID:27803736

  5. Recanalization of the lower leg. PTA or stent?; Rekanalisation am Unterschenkel. PTA oder Stent

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Huelsbeck, S. [Medizinischer Klinikverbund Flensburg, Ev.-Luth. Diakonissenanstalt zu Flensburg, Zentrum fuer Gesundheit und Diakonie, Abt. Diagnostische und Interventionelle Radiologie/Neuroradiologie, Flensburg (Germany)

    2010-01-15

    Percutaneous transluminal angioplasty (PTA) and stent placement are currently accepted methods for endovascular treatment of critical limb ischemia, if infragenual vessels are involved. Outcome results in high technical success and satisfactory clinical results for treatment of infrapopliteal lesions with regard to patency rates and amputation-free survival. These treatment modalities are also safe for the patients. The question whether PAT alone or additional stent placement is the better choice, is still unanswered due to limited data. (orig.) [German] Die perkutane transluminale Angioplastie (PTA) und die Stentimplantation stellen inzwischen akzeptierte Methoden zur Behandlung der kritischen Extremitaetenischaemie bei Beteiligung infragenualer Gefaesse dar. Diese Behandlungsmodalitaeten haben eine hohe technische Erfolgsrate, sind sicher fuer den Patienten und erbringen zufrieden stellende klinische Ergebnisse zur Therapie infrapoplitealer Laesionen hinsichtlich Offenheitsrate und amputationsfreiem Ueberleben. Die Frage, ob eine alleinige PTA oder die Stentimplantion besser ist, kann anhand der begrenzten derzeitigen Datenlage zur Zeit noch nicht hinreichend beantwortet werden. (orig.)

  6. 腔内支架植入术治疗国内Stanford B型主动脉夹层的系统评价%Endovascular stent-graft placement for the treatment of Stanford type B aortic dissection in China:A systematic review

    Institute of Scientific and Technical Information of China (English)

    王俊伟; 李勇辉; 李永欣; 崔进; 李文; 汪洋; 王深明; 王劲松

    2016-01-01

    ObjectiveTo summarize the efficacy, technique feasibility, and clinical safety of endovascular repair for Stanford type Baortic dissection (AD) in China.MethodsWe comprehensively searched the English-language medicalliterature in PubMed, Web of Science, and the Cochrane Library and the Chinese-language medical literatures in CBMdisc (Chinese Biomedical Database), CNKI (China National Knowledge Infrastructure), and Wanfang Data. This systematic review was based on all retrospective studies assessing outcomes of Stanford type BAD treated with endovascular stent-graft placement in China.ResultsA total of 153 retrospective studies that included 8 415 cases of type B AD were analyzed in this study. Procedure success was reported in (99.7±0.1)% of patients. Overall complications were reported in (19.1±0.6)% of patients. Postoperative endoleak occurred in (7.2±0.3)% of patients. Major complications were reported in (3.2±0.2)% of patients, with a neurological complication rate of (1.3±0.1)%. Periprocedural stroke occurred more frequently than paraplegia (0.8%±0.1% versus 0.1%±0.04%). Overall complications was signiifcantly greater in patients treated with ifrst-generation stents compared with second-generation stents (25.1%±1.2% versus 9.5%±0.9%,P<0.001). The in-hospital mortality rate was (1.6±0.1)%. Additionally, (1.8±0.2)% of patients died during a mean follow-up period of (29.4±13.5) months. The Kaplan-Meier estimates of the overall survival rate were (99.0±0.1)% at 30 days, (98.5±0.2)% at 6 months, (98.4±0.2)% at 1 year, (98.1±0.2)% at 2 years, and (97.9±0.2)% at 5 years.ConclusionsEndovascular stent-graft placement is feasible and has a high technique success rate and favorable neurological complication and survival rates in treating Stanford type B AD. Technique improvements in stent-graft design and device delivery catheters have attempted to address previously encountered dififculties. The second-generation of stent-grafts has better in

  7. Neoatherosclerosis in the stent

    Directory of Open Access Journals (Sweden)

    A. A. Komkov

    2015-01-01

    Full Text Available Achievements of interventional cardiology in the treatment of coronary artery disease are based on coronary balloon angioplasty with implanting bare metal stents and drug eluting stents. Questions of complications such as early stent thrombosis and restenosis of stent were solved in a considerable degree. However, with the lengthening of the followup period, the problem of late complications became obvious. Except endothelization and fibromuscular proliferation in stented coronary arteries the process of plaque formation has an important influence on later complications in follow-up period more than one year. This process was defined as neoatherosclerosis. This is verified by clinical manifestations of the disease, histological studies, angioscopy, intravascular ultrasound and optical-coherence tomography in stented patients. Dynamic observation of the condition in stentedcoronary arteries showed multistep proliferation with restenosis, its regression, and neoatherosclerosis development. Evidences of neoatherosclerosis formation in stented coronary arteries are considered in this review.

  8. Usefulness of biodegradable stents constructed of poly-/-lactic acid monofilaments in patients with benign esophageal stenosis

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    AIM: To report 13 patients with benign esophageal stenosis treated with the biodegradable stent.METHODS: We developed a Ultraflex-type stent by knitting poly-l-lactic acid monofilaments.RESULTS: Two cases were esophageal stenosis caused by drinking of caustic liquid, 4 cases were due to surgical resection of esophageal cancers, and 7 cases were patients with esophageal cancer who received the preventive placement of biodegradable stents for postendoscopic mucosal dissection (ESD) stenosis. The preventive placement was performed within 2 to 3 d after ESD. In 10 of the 13 cases, spontaneous migration of the stents occurred between 10 to 21 d after placement. In these cases, the migrated stents were excreted with the feces, and no obstructive complications were experienced. In 3 cases, the stents remained at the proper location on d 21 after placement. No symptoms of re-stenosis were observed within the follow-up period of 7 mo to 2 years. Further treatment with balloon dilatation or replacement of the biodegradable stent was not required.CONCLUSION: Biodegradable stents were useful for the treatment of benign esophageal stenosis, particularly for the prevention of post-ESD stenosis.

  9. Multimodal stone therapy for two forgotten and encrusted ureteral stents: a case report

    Science.gov (United States)

    2009-01-01

    Introduction Ureteral stent placement is a common procedure in daily urologic practice. To manage the problems of forgotten stents for many years needs multimodal stone therapy. Case presentation We present a case of a 26-years-old Caucasian, white woman with two forgotten encrusted ureteral stents for 48 months. Multimodal stone therapy including extracorporeal shock wave (SWL), percutaneous nephrolithotomy (PCNL), ureterorenoscopy (URS), cystolithotripsy with Lithoclast, and open surgery was necessary to remove all the stones. Using the described combination of techniques, our patient was rendered stone and stent free. Urologists should bear in mind the presence of severe encrustations when they have to deal with a forgotten stent. Conclusion This case shows that combined urologic techniques can achieve successful and safe management of forgotten stents, but treatment should be tailored to the volume of encrustation and associated stone. PMID:19183439

  10. Intravascular ultrasound assessment of very late bare-metal stent thrombosis: a case report

    Institute of Scientific and Technical Information of China (English)

    Ji Hyun Lee; Kyung Min Kim; Jun Won Lee; Sung Gyun Ahn; Young Jin Youn

    2012-01-01

    Very late stent thrombosis (VLST) is increasingly being regarded as a complication of drug-eluting stents (DES),and delayed endothelization,local hypersensitivity reactions,and late stent malapposition due to excessive positive remodeling have been postulated as mechanisms.Considering that stent endothelialization seems to be completed within 4 weeks following bare-metal stent (BMS) placement and that BMS do not possess antiproliferative coating,the mechanism of VLST may differ between patients with DES and those with BMS.We report a case of VLST 9 years after BMS implantation,in which thrombus from the ruptured neointima was confirmed by intravascular ultrasound.This finding suggests that de novo plaque rupture at the neointimal layer within the stent may be one of the explanations for VLST.

  11. Kissing-stents technique after living-donor lobar lung transplantation.

    Science.gov (United States)

    Sugimoto, Seiichiro; Oto, Takahiro; Toyooka, Shinichi; Miyoshi, Shinichiro

    2015-06-01

    Stent placement has become common practice for bronchial stenosis (BS) after lung transplantation (LT). Especially, segmental BS after lobar LT requires a complex stenting technique. We describe a case of multiple segmental bronchial stenoses treated by the kissing-stents technique using balloon-expandable metallic stents after living-donor lobar LT. Based on the vascular kissing-stents technique, we simultaneously placed two stents, side by side, in the superior segmental bronchus and the basal segmental bronchus of the right transplanted lobar lung. This technique may represent a valuable option for complex segmental BS after lobar LT. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Stenting plus coiling: dangerous or helpful?; Stenting plus Coiling bei akut rupturierten intrakraniellen Aneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, I.; Gizewski, E.; Doerfler, A.; Stolke, D.; Forsting, M. [Essen Univ. (Germany). Inst. fuer Radiologie und Neuroradiologie

    2005-09-01

    Purpose: the purpose of this study was to evaluate the procedural risk of treating acute ruptured aneurysms with a stentcoil combination. Material and methods: between August 2001 and January 2004 we treated nine acute subarachnoid hemorrhage (SAH) patients with a combination of stents and platinum coils. Results: six aneurysms were 100% eliminated; the residual three aneurysms had a 95% to 99% occlusion. A transient thrombosis in the stent in one patient could be recanalized by intravenous application of ReoPro {sup registered}. In another patient an occlusive vasospasm at the distal end of the stent was successfully treated with intraarterial Nimotop {sup registered}. Neurological complications occurred in none of the patients. Conclusion: in broad-based aneurysms which cannot be clipped or in which any neurosurgical treatment presents an unacceptably high risk (posterior circulation and paraophthalmic aneurysms), treatment using a combination of stent and platinum coils might be an option even in the acute phase of an SAH. Platelet aggregation can be treated with Aspirin registered and Plavix {sup registered} after placement of the first coil, vasospasms with intraarterial Nimotop {sup registered}, and acute stent thrombosis with GP IIa/IIIb-antagonists. (orig.)

  13. RX Herculink Elite® renal stent system: a review of its use for the treatment of renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Colyer Jr

    2012-08-01

    Full Text Available William R Colyer JrDivision of Cardiovascular Medicine, University of Toledo Medical Center, Toledo, OH, USAAbstract: The management of renal artery stenosis (RAS remains controversial. While some evidence suggests that treatment with stent placement is beneficial, randomized trials have failed to demonstrate a significant benefit. Ongoing clinical trials should help to better define the role for stenting of RAS while avoiding limitations seen with earlier trials. When it comes to stenting for RAS, several stents have been used; however, many stents which have been used previously and which are still being used are biliary stents that are used “off-label.” These stents have typically come onto the market through the 510(k pathway. To date, a total of five stents have been approved by the United States Food and Drug Administration for use in the renal arteries. Of the five stents that have received approval, the Bridge™ Extra Support (Medtronic CardioVascular, Santa Rosa, CA and the Palmaz® (Cordis Corporation, Bridgewater, NJ stents are no longer available. Currently, the Express® SD (Boston Scientific, Natick, MA, Formula™ (Cook Medical, Bloomington, IN, and Herculink Elite® (Abbott Vascular, Santa Clara, CA stents are Food and Drug Administration approved and available for use. The Herculink Elite is the most recently approved of the renal stents, having received approval in late 2011. The Herculink Elite stent is the only cobalt chromium stent approved for use in the renal arteries. Although trial data are limited and direct comparisons among renal stents is not possible, the Herculink Elite stent has demonstrated good performance. Additionally, the design of the Herculink Elite offers some advantages that may translate into improved outcomes.Keywords: renal artery stenosis, stenting, FDA approval

  14. Hyperperfusion syndrome after carotid stent angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Reith, W.; Krick, C.; Karp, K.; Zimmer, A.; Struffert, T.; Kuehn, A.L.; Papanagiotou, P. [University of the Saarland, Department for Interventional and Diagnostic Neuroradiology, Homburg (Germany); Roth, C.; Haass, A. [University of the Saarland, Clinic for Neurology, Homburg (Germany)

    2009-03-15

    This study assesses the incidence and causes of hyperperfusion syndrome occurring after carotid artery stenting (CAS). We retrospectively reviewed the clinical database of 417 consecutive patients who were treated with CAS in our department to identify patients who developed hyperperfusion syndrome and/or intracranial hemorrhage. Magnetic resonance imaging (MRI) including fluid-attenuated inversion recovery and diffusion-weighted imaging was performed before and after CAS in 269 cases. A Spearman's rho nonparametric correlation was performed to determine whether there was a correlation between the occurrence/development of hyperperfusion syndrome and the patient's age, degree of stenosis on the stented and contralateral side, risk factors such as diabetes, smoking, hypertension, adiposity, gender and fluoroscopy time, and mean area of postprocedural lesions as well as preexisting lesions. Significance was established at p < 0.05. Of the 417 carotid arteries stented and where MRI was also completed, we found hyperperfusion syndrome in 2.4% (ten cases). Patients who had preexisting brain lesions (previous or acute stroke) were at a higher risk of developing hyperperfusion syndrome (p = 0.022; Spearman's rho test). We could not validate any correlation with the other patient characteristics. Extensive microvascular disease may be a predictor of hyperperfusion syndrome after carotid stent placement. We believe that further studies are warranted to predict more accurately which patients are at greater risk of developing this often fatal complication. (orig.)

  15. A comparative study of short- and medium-term outcomes comparing emergent surgery and stenting as a bridge to surgery in patients with acute malignant colonic obstruction.

    LENUS (Irish Health Repository)

    Kavanagh, Dara O

    2013-04-01

    The use of self-expanding metal stents as a bridge to surgery in the setting of malignant colorectal obstruction has been advocated as an acceptable alternative to emergency surgery. However, concerns about the safety of stenting have been raised following recent randomized studies.

  16. Balloon-expandable covered stent therapy of complex endovascular pathology.

    Science.gov (United States)

    Giles, Heath; Lesar, Christopher; Erdoes, Luke; Sprouse, Richard; Myers, Stuart

    2008-11-01

    The current study was designed to investigate our hypotheses that balloon-expandable covered stents display acceptable function over longitudinal follow-up in patients with complex vascular pathology and provide a suitable alternative for the treatment of recurrent in-stent restenosis. All stents were Atrium iCast, which is a balloon-mounted, polytetrafluoroethylene-covered stent with a 6F/7F delivery system. A retrospective review was performed of 49 patients with 66 stented lesions. Data were analyzed with life tables and t-tests. The most commonly treated vessels were the iliac (61%) and renal (24%) arteries. Indications for covered stent placement were unstable atheromatous lesions (50%), recurrent in-stent restenosis (24%), aneurysm (8%), aortic bifurcation reconstruction (7.5%), dissection (4.5%), endovascular aneurysm repair-related (4.5%), and stent fracture (1.5%). Patency was assessed by angiogram or duplex ultrasonography. The primary end point was patency and secondary end points were technical success and access-site complications. Mean follow-up was 13 months (range 1.5-25). The technical success rate was 97%. Unsuccessful outcomes were due to deployment error (n=1) and stent malpositioning (n=1). The cohort (n=64) 6- and 12-month primary patency rates were 96% and 84%, respectively. Twelve-month assisted primary patency was 98%. Iliac artery stents (n=38) had a primary patency of 97% at 6 months and 84% at 12 months with an assisted primary patency of 100% at 12 months. Renal artery stents (n=16) had a primary patency of 92% at 6 months and 72% at 12 months with an assisted primary patency of 92% at 6 and 12 months. Stents placed for recurrent in-stent restenosis (n=16) had a primary patency of 85%, assisted primary patency of 93%, and a 15% restenosis rate at 12 months. Specifically, stents placed for renal artery recurrent in-stent restenosis (n=10) had a primary patency of 73%, assisted primary patency of 82%, and a restenosis rate of 27%. The

  17. The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Huang Mingsheng [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Shan Hong [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China)]. E-mail: gzshsums@public.guangzhou.gd.cn; Jiang Zaibo [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Li Zhengran [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Zhu Kangshun [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Guan Shouhai [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Qian Jiesheng [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Chen Guihua [Transplantation Center, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Lu Minqiang [Transplantation Center, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Yang Yang [Transplantation Center, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China)

    2006-12-15

    Purpose: This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). Materials and methods: Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepatic artery stenosis (HAS). Fourteen of them underwent coronary stent placement in the HAS. The technical results, complications, hepatic artery patency and clinical outcome were reviewed. Results: Technical and immediate success was 100%. After a mean follow-up of 159.4 days (range, 9-375 days), all patients obtained patent hepatic arteries except 2 patients occurred hepatic artery restenoses at 26 and 45 days after stent placement, respectively. Kaplan-Meier curve of patency showed cumulated stent patency at 3, 6, and 12 months of 78%, 58% and 45%, respectively. During the follow-up, 8 patients survived, 5 died of septic multiple-organ failure, 1 received retransplantation because of refractory biliary infection. Hepatic artery dissection induced by a guiding catheter occurred in one patient and was successfully treated with a coronary stent. Conclusion: Hepatic artery stenosis after OLT can be successfully treated with coronary stent placement with low complication rate and an acceptable 1-year hepatic artery patency rate.

  18. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar;

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  19. Endovascular therapy for abdominal aortic aneurysm and iliac artery aneurysm using SEAL aortic stent-graft: A single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Young; Kim, Jeong Ho; Byun, Sung Su; Kang, Jin Mo; Choi, Sang Tae; Park, Jae Hyung [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2015-03-15

    The aim of this study was to evaluate the safety and efficacy of SEAL aortic stent-graft for abdominal aortoiliac aneurysms. Between October 2007 and January 2014, 33 patients with abdominal aortoiliac aneurysms were treated with SEAL aortic stent-graft. We evaluated the technical success rate, clinical and CT follow-up periods, major complications, need for additional interventional treatment, aneurysm-related mortality and clinical success rate. SEAL bifurcated aortic stent-graft was successfully placed in 32 patients (97%). Clinical and CT follow-up periods were 24 and 14 months, respectively. Endoleak developed in 13 patients (41%): spontaneous regression or decrease in 6, need for additional treatment in 4 and follow-up loss in 3. Significant stenosis of stent-graft occurred in 4 patients (12%) and was treated with stenting in 3. Migration of stent-graft was noted in 3 patients (9%) and treated with additional stent-grafting. Aneurysm-related mortality was 9% (3 of 33). The placement of SEAL stent-graft was effective in 26 patients (79%). The placement of SEAL aortic stent-graft was safe and effective in patients with aneurysms of abdominal aorta and iliac arteries. However, complicating endoleaks, stenosis and migration of the stent-graft developed during the follow-up. Therefore, regular CT follow-up seems to be mandatory.

  20. Magnesium alloy covered stent for treatment of a lateral aneurysm model in rabbit common carotid artery: An in vivo study

    Science.gov (United States)

    Wang, Wu; Wang, Yong-Li; Chen, Mo; Chen, Liang; Zhang, Jian; Li, Yong-Dong; Li, Ming-Hua; Yuan, Guang-Yin

    2016-11-01

    Magnesium alloy covered stents have rarely been used in the common carotid artery (CCA). We evaluated the long-term efficacy of magnesium alloy covered stents in a lateral aneurysm model in rabbit CCA. Magnesium alloy covered stents (group A, n = 7) or Willis covered stents (group B, n = 5) were inserted in 12 New Zealand White rabbits and they were followed up for 12 months. The long-term feasibility for aneurysm occlusion was studied through angiograms; the changes in vessel area and lumen area were assessed with IVUS. Complete aneurysmal occlusion was achieved in all aneurysms. Angiography showed that the diameter of the stented CCA in group A at 6 and 12 months was significantly greater than the diameter immediately after stent placement. On intravascular ultrasound (IVUS) examination, the mean lumen area of the stented CCA in group A was significantly greater at 6 and 12 months than that immediately after stent placement; the mean lumen area was also significantly greater in group A than in group B at the same time points. The magnesium alloy covered stents proved to be an effective approach for occlusion of lateral aneurysm in the rabbit CCA; it provides distinct advantages that are comparable to that obtained with the Willis covered stent.

  1. A Novel Thin Film Nitinol Covered Neurovascular Stent Significantly Decreases Intra-Aneurysmal Flow In Vitro

    Science.gov (United States)

    Chun, Youngjae; Hur, Soojung; Shayan, Mahdis; Kealey, Colin; Levi, Daniel; Mohanchandra, Kp; di Carlo, Dino; Carman, Gregory

    2013-11-01

    A novel thin film nitinol (TFN) stent has been developed to promote aneurysm quiescence by diminishing flow across the aneurysm's neck. Laboratory aneurysm models were used to assess the flow changes produced by stents covered with different patterns of TFN. Flow diversion stents were constructed by covering Wingspan stents (Boston Scientific, DxL:4x20mm) with TFNs (i.e., 77 and 82 percent porosity). The flow changes that occur after deployment of two different porous TFN covered stent in intracranial aneurysm models were evaluated in vitro. The 82 percent porous TFN covered stent reduced the intra-aneurysmal mean flow velocity by 86.42 percent, while a 77 percent porous TFN covered stent reduced to intra-aneurysmal mean flow velocity to 93.44 percent compared to a nonstented model. Local wall shear rates were also significantly reduced in wide-neck aneurysm model (i.e., 97.52 - 98.92 percent) with TFN stent placement. The results showed that TFN covered stents significantly reduced intra-aneurysmal flow velocity magnitudes and local wall shear rates. This suggests that TFN covered stents with both 77 and 82 percent porosity have great potential to promote thrombosis in both wide-necked and fusiform aneurysm sacs.

  2. 主动脉弓三分支覆膜支架在Stanford A型急性主动脉夹层外科治疗中的应用%The application of triple branches aortic arch stent-graft placement in the surgical treatment of acute Stanford type A aortic dissection

    Institute of Scientific and Technical Information of China (English)

    华菲; 沈振亚; 余云生; 叶文学; 黄浩岳

    2011-01-01

    was transected near the base of the innominate artery.From the incision, the triple-branched stent graft was implantated into the true lumen of the arch,descending aorta and the aorta bifurcation vessel. The transected stump of the ascending aorta was anastomosis to the proximal of the branched blood vessel prosthesis.Results Cardiopulmonary bypass time was (186 ±38) min,cross clamp time was (101 ±27) min,and average selective cerebral perfusion and lower body arrest time was ( 39 ± 11 ) min.The in-hospital mortality was zero.One patient of transient postoperative neurologic dysfunction, one of acute renal failure, one of transient limbs disturbance, one of secondary thoracotomy operation, one of gastrointestinal hemorrhage and one of postoperative chylothorax were observed.CT angiography rechecked showed the position of the vascular stent were satisfactory and the blood flow of arterial branches stents were lucid .The false lumen of the aortic arch and descending aorta closed with thrombus or shrinked.Conclusions The patients required aortic arch to be reconstructed which had no main tearing of intima in the arch may be best candidates for this technique.Open triple-branched stent graft placement combined ascending aorta replacement is an effective means for aortic arch reconstruction in acute Stanford type A aortic dissection.

  3. Drug-eluting stents below the knee.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Callaert, J; Keirse, K; Verbist, J; Peeters, P

    2011-04-01

    The fear that early thrombosis and late luminal loss due to intimal hyperplasia formation potentially leads to insufficient long-term patency rates can explain the reluctance on implanting stents in small diameter below-the-knee (BTK) arteries. Drug-eluting stent (DES) technology was developed to prevent early thrombosis and late luminal loss to potentially improve long-term patency rates. Currently, the first level 1 evidence from prospective, randomized, controlled DESTINY and ACHILLES studies indicate that the implantation of DES in short lesion lenghts in the infrapopliteal vasculature leads to favorable outcomes with high primary patency rates. This makes that primary DES placement can be recommended as treatment strategy in short BTK-lesions.

  4. Temporary endoscopic metallic stent for idiopathic esophageal achalasia.

    Science.gov (United States)

    Coppola, Franco; Gaia, Silvia; Rolle, Emanuela; Recchia, Serafino

    2014-02-01

    Idiopathic achalasia is a motor disorder of the esophagus of unknown etiology caused by loss of motor neurons determining an altered motility. It may determine severe symptoms such as progressive dysphagia, regurgitations, and pulmonary aspirations. Many therapeutic options may be offered to patients with achalasia, from surgery to endoscopic treatments such as pneumatic dilation, botulinum injection, peroral endoscopic myotomy, or endoscopic stenting. Recently, temporary placement of a stent was proposed by Cheng as therapy for achalasia disorders, whereas no Western authors have dealt with it up to date. The present study reports our preliminary experience in 7 patients with achalasia treated with a temporary stent. Partially covered self-expanding metallic stents (Micro-Tech, Nanjin, China) 80 mm long and 30 mm wide were placed under fluoroscopic control and removed after 6 days. Clinical follow-up was scheduled to check endoscopic success, symptoms release, and complications. The placement and the removal of the stents were obtained in all patients without complications. Mean clinical follow-up was 19 months. Five out of 7 patients referred total symptoms release and 2 experienced significant improvement of dysphagia. The procedure was not time consuming and was safe; no mild or severe complications were registered. In conclusion, our results may suggest a possible safe and effective endoscopic alternative treatment in patients with achalasia; however, further larger studies are necessary to confirm these promising, but very preliminary, data.

  5. Positioning value of localizing scaleplate during the metal esophageal stent placement under Xray%预先放置定位标尺在X线下行金属食管支架置入术的定位价值

    Institute of Scientific and Technical Information of China (English)

    程鹏; 郭红丽; 李鸿远; 曹玮

    2012-01-01

    目的 通过透视下预先放置定位标尺或放置体表标志物,明确不同定位方法在X线下行食管支架置入术中的定位价值.方法 45例在小C型臂X线机下行食管支架植入患者(透视下放置标志物15例,预先放置标尺30例,其中栅格型标尺15例,自制数字标尺15例),分别记录每个病例用于定位在X射线下曝光的时间,然后计算出不同定位方法的平均时间并进行比较.结果 透视下放置标志物定位,造影及多方位观察平均用时(29±0.8) s;预先放置栅格型定位标尺者,造影定位平均用时(12±0.5)s(P<0.05);预先放置自制数字定位标尺者,造影定位平均用时(8±0.3) s(P<0.05).结论 在放置金属食管支架术中,预先放置自制数字定位标尺,可以明显减少术中用于定位暴露在X线下照射的时间,减轻了辐射对人体健康的影响,可以作为基层医院定位的一种好的、实用的参考方法.%Objective To observe the positioning value of different localizing scalcplatcs during the metal esophageal stcnt placement implantation under X-ray. Methods 45 cases (15 cases were prc-placcd with metal markers, 30 cases were prc-placcd with localizing scalcplatcs of which the grid scale in 15 cases and homemade digital scale in 15 cases ) underwent intcrvcntional treatment with esophageal metal stcnt under fluoroscopic at the small C-arm X-ray machine. The X-ray exposure time were recorded separately for each localizing method under fluoroscopy,and the average times of different kinds of positioning methods were calculate. Results Under fluoroscopy, the mean X-ray exposure time in placing the metal markers was(29 ± 0. 8) s by contrast and multi-directional mcthodjthc mean X-ray exposure time in placing the grid positioning scale was (12 ± 0. 5) s(P< 0. 05 )and the mean X-ray exposure time in placing prcpositioncd self-made digital positioning scale was (8 ± 0. 3) s(P< 0. 05 ). Conclusion During the metal esophageal stcnt

  6. Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G;

    2012-01-01

    Background. Self-expanding metal stents can alleviate malignant colonic obstruction in incurable patients and avoid palliative stoma surgery. Objective. Evaluate stent effectiveness and safety on palliation of patients with malignant colorectal strictures. Design. Two prospective, one Spanish...... and one global, multicenter studies. Settings. 39 centers (22 academic, 17 community hospitals) from 13 countries. Patients. A total of 257 patients were enrolled, and 255 patients were treated with a WallFlex uncovered enteral colonic stent. Follow-up was up to 12 months or until death or retreatment...

  7. Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten

    Energy Technology Data Exchange (ETDEWEB)

    Landwehr, P.; Lackner, K. (Wuerzburg Univ. (Germany, F.R.). Inst. fuer Roentgendiagnostik); Goetz, R. (Wuerzburg Univ. (Germany, F.R.). Abt. fuer Nephrologie)

    1990-09-01

    On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

  8. Renal vein stenting via the right internal jugular approach with a provocative Valsalva maneuver to reduce the risk of stent migration.

    Science.gov (United States)

    Syed, Mubin I; Yu, Benjamin; Akhter, Talal; Shaikh, Azim

    2011-12-01

    An adult male with nutcracker syndrome was treated successfully by placement of a self-expanding stent in the left renal vein via a right internal jugular vein approach with a provocative Valsalva maneuver. Previous case reports have described renal vein stenting for this condition via common femoral vein approach. However, this study proposes the right internal jugular vein approach as a safer method for the treatment of nutcracker syndrome since the stent can be easily captured along the guidewire if undersized. This technique is based on the realization that the left renal vein diameter may increase by 50% to 58% during the Valsalva maneuver.

  9. In vitro comparison of different carotid artery stents: a pixel-by-pixel analysis using CT angiography and contrast-enhanced MR angiography at 1.5 and 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Lettau, Michael; Sauer, Annett; Heiland, Sabine; Rohde, Stefan; Reinhardt, Julia; Bendszus, Martin; Haehnel, Stefan [University of Heidelberg, Medical Center, Division of Neuroradiology, Department of Neurology, Heidelberg (Germany)

    2010-09-15

    CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. The purpose of this study was to compare CTA, contrast-enhanced MRA (CEMRA) at 1.5 T, and CEMRA at 3 T for the visualization of carotid artery stents and to define the best noninvasive imaging technique for each stent. CTA and CEMRA appearances of 18 carotid artery stents of different designs and sizes (4.0 to 10.0 mm) were investigated in vitro. The profile of the contrast-to-noise ratio (CNR) of the lumen of each stent was calculated semiautomatically by a pixel-by-pixel analysis using the medical imaging software OSIRIS {sup registered}. For each stent, artificial lumen narrowing (ALN) was calculated. In all but one stents, ALN was lower on CEMRA at 3 T than at 1.5 T. With CEMRA at 3 T and at 1.5 T, ALN in most nitinol stents was lower than in the groups of stainless steel and cobalt alloy stents. In most nitinol stents, ALN on CEMRA at 3 T was lower than on CTA. In all stainless steel stents and cobalt alloy stents, ALN was lower on CTA than on CEMRA. With CTA and CEMRA, in most stents ALN decreased with increasing stent diameter. CTA and CEMRA evaluation of vessel patency after stent placement is possible, but considerably impaired by ALN. Investigators should be informed about the method of choice for every stent. (orig.)

  10. Role of colonic stents in the management of colorectalcancers

    Institute of Scientific and Technical Information of China (English)

    2016-01-01

    Colorectal cancer is one of the commonly encounteredcancers across the Western World. In United Kingdom,this constitutes third most common ranked cancer andsecond most common ranked cause of cancer relateddeaths. Its acute presentation as a malignant colonicobstruction imposes challenges in its management.Colonic stent has been used for many years to alleviateSubmit a Manuscript http://www.wjgnet.com/esps/Help Desk: http://www.wjgnet.com/esps/helpdesk.aspxDOI: 10.4253/wjge.v8.i4.198World J Gastrointest Endosc 2016 February 25; 8(4): 198-204ISSN 1948-5190 (online)? 2016 Baishideng Publishing Group Inc. All rights reserved.acute obstruction in such cases allowing optimisationof patient's physiological status and adequate stagingof cancer. In this review, current literature evidenceregarding use of colonic stent in acute malignant colonicobstruction is critically appraised and recommendationson the use of colonic stent are advocated.

  11. Biocompatibility of Coronary Stents

    Directory of Open Access Journals (Sweden)

    Thamarasee M. Jeewandara

    2014-01-01

    Full Text Available Cardiovascular disease is the dominant cause of mortality in developed countries, with coronary artery disease (CAD a predominant contributor. The development of stents to treat CAD was a significant innovation, facilitating effective percutaneous coronary revascularization. Coronary stents have evolved from bare metal compositions, to incorporate advances in pharmacological therapy in what are now known as drug eluting stents (DES. Deployment of a stent overcomes some limitations of balloon angioplasty alone, but provides an acute stimulus for thrombus formation and promotes neointimal hyperplasia. First generation DES effectively reduced in-stent restenosis, but profoundly delay healing and are susceptible to late stent thrombosis, leading to significant clinical complications in the long term. This review characterizes the development of coronary stents, detailing the incremental improvements, which aim to attenuate the major clinical complications of thrombosis and restenosis. Despite these enhancements, coronary stents remain fundamentally incompatible with the vasculature, an issue which has largely gone unaddressed. We highlight the latest modifications and research directions that promise to more holistically design coronary implants that are truly biocompatible.

  12. Stents in patients with esophageal cancer before chemoradiotherapy: high risk of complications and no impact on the nutritional status.

    Science.gov (United States)

    Mão-de-Ferro, S; Serrano, M; Ferreira, S; Rosa, I; Lage, P; Alexandre, D P; Freire, J; Mirones, L; Casaca, R; Bettencourt, A; Pereira, A D

    2016-03-01

    Preoperative chemoradiotherapy is the standard of care for locally advanced esophageal cancer, causing persistent deterioration in the nutritional status. We performed a prospective study to evaluate the safety and efficacy of esophageal double-covered self-expandable metal stents in patients with esophageal cancer before chemoradiotherapy. The nutritional status and dysphagia were prospectively recorded. Eleven patients were included: eight were moderate and three were severely malnourished. After stent placement, dysphagia improved in all patients. With regard to complications, one patient developed an esophageal perforation that required urgent esophagectomy. Four patients presented stent migration. Three of these patients required enteral nutrition and none was submitted to surgery because of poor nutritional status. Of the other six patients, only four were operated upon. Stent placement presented a high complication rate and did not prevent weight loss or malnutrition. Other alternatives, including naso-gastric tube placement or endoscopic percutaneous gastrostomy or jejunostomy, should be considered.

  13. How to decide on stent insertion or surgery in colorectalobstruction?

    Institute of Scientific and Technical Information of China (English)

    2016-01-01

    Colorectal cancer is one of the most common cancers inwestern society and malignant obstruction of the colonaccounts for 8%-29% of all large bowel obstructions.Conventional treatment of these patients with malignantobstruction requiring urgent surgery is associated witha greater physiological insult on already nutritionallyreplete patients. Of late the utility of colonic stents hasoffered an option in the management of these patientsin both the palliative and bridge to surgery setting. Thishas been the subject of many reviews which highlightits efficacy, particulary in reducing ostomy rates,allowing quicker return to oral diet, minimising extendedpost-operative recovery as well as some quality of lifebenefits. The uncertainity in managing patients withmalignant colonic obstructions has lead to a morecautious use of stenting technology as community equipoiseexists. Decision making analysis has demonstratedthat surgeons' favored the use of stents in the palliativesetting preferentially when compared to the curativesetting where surgery was preferred. We aim to reviewthe literature regarding the use of stent or surgery incolorectal obstruction, and then provide a discourse withregards to the approach in synthesising the data andapplying it when deciding the appropriate application ofstent or surgery in colorectal obstruction.

  14. Forgotten urological stent.

    Science.gov (United States)

    Bhuiyan, Z H; Bhuiyan, N I; Khan, S A; Tawhid, M H; Islam, M F

    2011-10-01

    "Forgotten" Ureteral stent DJ stent related complication is not uncommon even in the era of modern urology in the developed world. In this context we have undertaken a retro-prospective study in relation to its various causes, complications, management and prevention of forgotten stents in a single teaching institute. The study period was from January'04 to December'09. The sample size was 60. The effect of "forgotten stent" in our study reflects mild UTI to various complications including severe renal failure. We had approached all of our cases judiciously using various modalities of minimal access endourological techniques either alone or in combinations with successful outcome. The study concluded that it is vary easy to prevent "forgotten stent" and so its complications. However if we confront such unwanted complications that could be managed successfully with the use of endourological techniques. We did not use other techniques like laparoscopy and open surgery in this study.

  15. Sediment Placement Areas 2012

    Data.gov (United States)

    California Department of Resources — Dredge material placement sites (DMPS), including active, inactive, proposed and historical placement sites. Dataset covers US Army Corps of Engineers San Francisco...

  16. Everolimus-eluting coronary stents

    Directory of Open Access Journals (Sweden)

    Alejandro Saez

    2010-09-01

    Full Text Available Alejandro Saez, Raul MorenoDivision of Interventional Cardiology, University Hospital La Paz, Madrid, SpainAbstract: Bare metal stents enabled a reduction in the risk of early procedural complications and restenosis in comparison with balloon angioplasty alone, but introduced a new and device-specific iatrogenic condition, ie, in-stent restenosis due to increased neointimal hyperplasia. Sirolimus- and paclitaxel-eluting stents reduce restenosis and the need for new revascularizations in comparison with bare metal stents, although at the cost of a slight increase in the risk of late stent thrombosis and a need for prolonged dual antiplatelet therapy. Everolimus is an analog of sirolimus with an increased solubility. In this review, the currently available evidence for everolimus-eluting stents is revised, including randomized trials against bare metal stents, and head-to-head trials comparing this stent with other drug-eluting stents.Keywords: coronary stents, restenosis, everolimus, review

  17. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Deepak, E-mail: deepakjain02@yahoo.com; Arora, Ankur, E-mail: aroradrankur@yahoo.com [Institute of Liver and Biliary Sciences, Department of Radiology (India); Deka, Pranjal, E-mail: drpranjaldeka@gmail.com [Institute of Liver and Biliary Sciences, Department of Hepatopancreatobiliary Surgery (India); Mukund, Amar, E-mail: dramarmukund@gmail.com; Bhatnagar, Shorav, E-mail: drshorav@yahoo.com [Institute of Liver and Biliary Sciences, Department of Radiology (India); Jindal, Deepti, E-mail: deepijindal@rediffmail.com; Kumar, Niteen, E-mail: drniteenkumar@gmail.com; Pamecha, Viniyendra, E-mail: viniyendra@yahoo.co.uk [Institute of Liver and Biliary Sciences, Department of Hepatopancreatobiliary Surgery (India)

    2013-08-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft.

  18. Paraplegia after aortic and superior mesenteric artery stenting for occlusive disease.

    Science.gov (United States)

    Hans, Sachinder S; Ngo, William; McAllister, Michael

    2014-02-01

    Paraplegia after endovascular therapy for aortic and visceral artery occlusive disease is an extremely uncommon occurrence. Two cases of paraplegia after placement of an aortic covered stent for infrarenal aortic stenosis and a superior mesenteric artery stent for chronic visceral ischemia are presented. In both patients, embolization of the arterial supply to the spinal cord was the presumed cause. One patient had a slight recovery after intense physical therapy and rehabilitation. The second patient did not have any recovery from her paraplegia.

  19. Drug Eluting Stents for Malignant Airway Obstruction: A Critical Review of the Literature

    Science.gov (United States)

    Hohenforst-Schmidt, Wolfgang; Zarogoulidis, Paul; Pitsiou, Georgia; Linsmeier, Bernd; Tsavlis, Drosos; Kioumis, Ioannis; Papadaki, Eleni; Freitag, Lutz; Tsiouda, Theodora; Turner, J Francis; Browning, Robert; Simoff, Michael; Sachpekidis, Nikolaos; Tsakiridis, Kosmas; Zaric, Bojan; Yarmus, Lonny; Baka, Sofia; Stratakos, Grigoris; Rittger, Harald

    2016-01-01

    Lung cancer being the most prevalent malignancy in men and the 3rd most frequent in women is still associated with dismal prognosis due to advanced disease at the time of diagnosis. Novel targeted therapies are already on the market and several others are under investigation. However non-specific cytotoxic agents still remain the cornerstone of treatment for many patients. Central airways stenosis or obstruction may often complicate and decrease quality of life and survival of these patients. Interventional pulmonology modalities (mainly debulking and stent placement) can alleviate symptoms related to airways stenosis and improve the quality of life of patients. Mitomycin C and sirolimus have been observed to assist a successful stent placement by reducing granuloma tissue formation. Additionally, these drugs enhance the normal tissue ability against cancer cell infiltration. In this mini review we will concentrate on mitomycin C and sirolimus and their use in stent placement. PMID:26918052

  20. The use of self-expanding silicone stents in esophageal cancer care: optimal pre-, peri-, and postoperative care.

    Science.gov (United States)

    Martin, Robert; Duvall, Ryan; Ellis, Susan; Scoggins, Charles R

    2009-03-01

    Preoperative nutritional supplementation, management of esophageal leaks, and postoperative anastomotic strictures still remain common problems in the management of esophageal cancer. Jejunal feeding tubes, total parenteral nutrition (TPN) with nasogastric suction, and repeated esophageal dilations remain the most common treatments, respectively. The aim of this study was to evaluate the use of removable silicone stents in (1) the preoperative nutritional optimization during neoadjuvant therapy, (2) the management of perioperative anastomotic leak, and (3) the management of postoperative anastomotic strictures. Review of our prospectively maintained esophageal database identified 15 patients who had removable self-expanding silicone stents placed in the management of one of these three management problems from July 2004 to August 2006. Preoperative therapy: Five patients underwent initial stent placement in preparation for neoadjuvant therapy. Dysphagia relief was seen in 100% of patients, with optimal caloric needs taken within 24 h of placement. All patients tolerated neoadjuvant therapy without delay from dehydration or malnutrition. One stent migration was found at the time of operation, which was removed without sequelae. Perioperative therapy: Five patients developed delayed (>10 days) esophageal leaks that were managed with removable esophageal stent and percutaneous drainage (in three patients). All patients had successful exclusion of the leak on the day of the procedure with resumption of oral intake on the evening of procedure. All five healed leaks without sequelae. Postoperative therapy: Five patients developed postoperative anastomotic strictures that required dilation and placement of removable esophageal stent. The median number of dilations was 1 (range 1-2), with all stents placed for approximate 3 months duration. All patients had immediate dysphagia relief after stent placement. Removable esophageal stents are novel treatment option to optimize

  1. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2011-07-15

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 {+-} 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  2. Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, Claus Christian, E-mail: Claus.christian.pieper@ukb.uni-bonn.de; Meyer, Carsten, E-mail: Carsten.Meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Rudolph, Jens, E-mail: jens.rudolph@ukb.uni-bonn.de; Verrel, Frauke, E-mail: frauke.verrel@ukb.uni-bonn.de [University of Bonn, Department of Surgery (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Wilhelm, Kai E., E-mail: kai.wilhelm@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)

    2013-08-01

    PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

  3. Gianturco metallic biliary stent in malignant biliary obstruction: results of follow-up in dead patients

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Kim, Chan Soo; Lee, Kyung Soo; Choi, See Sung; Won, Jong Jin; Kim, Haak Cheul; Chae, Kwon Mook [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1994-04-15

    In order to study the patency, restenosis, efficacy, and complication of the metallic stent in the course of treatment of malignant biliary obstruction, the results of follow up of the dead patients after stent insertion were reviewed. Self-expandable Gianturco metallic stent with 10-mm diameter was successfully inserted in 33 patients: 10 with Klatskin tumor, 7 with common bile duct cancer, 7 with gallbladder cancer, 5 with pancreatic cancer, 2 with recurred stomach cancer, one with periampullary cancer, one with hepatocellular carcinoma. The overall duration of survival and patency of the stents in 33 patients were 5.2 months(1-12 months) and 4.9 months(1-14 months), respectively. Restenosis of metallic stents was found in 9 cases(27%), after 6.1 months in average. Causes of stent occlusion were overgrowing of tumor in 5, overgrowing and ingrowing of tumor in 3, extraductal dislodgement in one case. Two cases of symptomatic cholangitis after stent placement were successfully treated with percutaneous cholecystostomy. Three cases of destruction and migration of metallic stents were found after 6 months. On the basis of our experience, insertion of Gianturco metallic biliary stent is an acceptable treatment method in the malignant biliary obstruction, especially for whom short term survival is expected.

  4. Efficacy of Self-Expandable Metallic Stent Inserted for Refractory Hemorrhage of Duodenal Cancer

    Directory of Open Access Journals (Sweden)

    Takashi Orii

    2016-05-01

    Full Text Available Because of advances in the technology of gastrointestinal endoscopy and improvements in the quality of stents, it has become routine to place a stent as palliative therapy for malignant gastrointestinal obstruction. On the other hand, stent placement for malignant gastrointestinal hemorrhage has scarcely been reported, although it may be performed for hemorrhage of the esophageal varicose vein. We recently experienced a patient with refractory hemorrhage from an unresectable duodenal cancer who underwent placement of a self-expandable metallic stent (SEMS and thereafter had no recurrence of the hemorrhage. A 46-year-old man underwent laparotomy to radically resect a cancer in the third portion of the duodenum, which invaded widely to the superior mesenteric vein and its branches and was considered unresectable. After stomach-partitioning gastrojejunostomy was performed, chemotherapy was initiated according to the regimen of chemotherapy of far advanced gastric cancer. One year and 4 months after induction of chemotherapy, gastrointestinal hemorrhage occurred. Upper gastrointestinal endoscopy revealed the hemorrhage oozing from the duodenal cancer, and endoscopic hemostasis, such as injection of hypertonic saline epinephrine and argon plasma coagulation, was unsuccessful. Twenty days after emergence of the hemorrhage, an endoscopic covered SEMS was placed with confirmation by fluoroscopy. Immediately after placement of the stent, the tarry stool stopped and the anemia ceased to progress. The recurrence of the hemorrhage has not been confirmed without migration of the stent. SEMS is an effective hemostatic procedure for malignant refractory hemorrhage.

  5. Treatment of malignant gastric outlet obstruction with endoscopically placed self-expandable metal stents

    Institute of Scientific and Technical Information of China (English)

    Jill KJ Gaidos; Peter V Draganov

    2009-01-01

    Malignant gastroduodenal obstruction can occur in up to 20% of patients with primary pancreatic, gastric or duodenal carcinomas. Presenting symptoms include nausea, vomiting, abdominal distention, pain and decreased oral intake which can lead to dehydration, malnutrition, and poor quality of life. Endoscopic stent placement has become the primary therapeutic modality because it is safe, minimally invasive, and a cost-effective option for palliation. Stents can be successfully deployed in the majority of patients. Stent placement appears to lead to a shorter time to symptomatic improvement, shorter time to resumption of an oral diet, and shorter hospital stays as compared with surgical options. Recurrence of the obstructive symptoms resulting from stent occlusion, due to tumor ingrowth or overgrowth, can be successfully treated with repeat endoscopic stent placement in the majority of the cases. Both endoscopic stenting and surgical bypass are considered palliative treatments and, to date, no improvement in survival with either modality has been demonstrated. A tailored therapeutic approach, taking into consideration patient preferences and involving a multidisciplinary team including the therapeutic endoscopist, surgeon, medical oncologist, radiation therapist, and interventional radiologist, should be considered in all cases.

  6. Mechanical Prevention of Post-ERCP Pancreatitis by Pancreatic Stents: Results, Techniques, and Indications

    Directory of Open Access Journals (Sweden)

    Tarnasky PR

    2003-01-01

    Full Text Available Impaired pancreatic drainage may be most important in the pathophysiology of post-ERCP pancreatitis. When there is a mechanical problem, there is often a mechanical solution. Pancreatic stenting reduces the incidence and severity of post-ERCP pancreatitis in high-risk patients. Young patients with suspected sphincter of Oddi dysfunction or prior pancreatitis and those undergoing procedures with either a difficult cannulation, precut and/or pancreatic sphincterotomy should be strongly considered for pancreatic stenting. Stents should be removed within about one week or have the proximal flaps removed to allow early spontaneous distal migration. Pancreatic stent placement following biliary intervention can occasionally be difficult. In cases where the primary goal is pancreatic therapy, one should consider establishing pancreatic access before addressing the bile duct. A pancreatic stent can then serve as a guide for sphincterotomy, but most importantly, protect against post-ERCP pancreatitis.

  7. Which spring is the best? Comparison of methods for virtual stenting.

    Science.gov (United States)

    Spranger, Katerina; Ventikos, Yiannis

    2014-07-01

    This paper presents a methodology for modeling the deployment of implantable devices used in minimally invasive vascular interventions. Motivated by the clinical need to perform preinterventional rehearsals of a stent deployment, we have developed methods enabling virtual device placement inside arteries, under the constraint of real-time application. This requirement of rapid execution narrowed down the search for a suitable method to the concept of a dynamic mesh. Inspired by the idea of a mesh of springs, we have found a novel way to apply it to stent modeling. The experiments conducted in this paper investigate properties of the stent models based on three different spring types: lineal, semitorsional, and torsional springs. Furthermore, this paper compares the results of various deployment scenarios for two different classes of devices: a stent graft and a flow diverter. The presented results can be of a high-potential clinical value, enabling the predictive evaluation of the outcome of a stent deployment treatment.

  8. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, Seoul (Korea); Seo, Tae-Seok [Gachon Medical School, Department of Radiology, Gil Medical Center, Inchon (Korea); Yuk, Soon Hong [Hannam University, Department of Polymer Science and Engineering, College of Engineering, Daejeon (Korea); Kim, Young-Hwa [Soonchunhyang University Chonan Hospital, Department of Radiology, Chonan (Korea); Cho, Yong-Mee [University of Ulsan College of Medicine, Department of Pathology, Asan Medical Center, Seoul (Korea)

    2005-06-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean{+-}standard deviation, 46.88{+-}23.75) than in the CS (73.75{+-}14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63{+-}2.05) than in CS (3.49{+-}2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  9. Endovascular Gene Delivery from a Stent Platform: Gene- Eluting Stents.

    Science.gov (United States)

    Fishbein, Ilia; Chorny, Michael; Adamo, Richard F; Forbes, Scott P; Corrales, Ricardo A; Alferiev, Ivan S; Levy, Robert J

    A synergistic impact of research in the fields of post-angioplasty restenosis, drug-eluting stents and vascular gene therapy over the past 15 years has shaped the concept of gene-eluting stents. Gene-eluting stents hold promise of overcoming some biological and technical problems inherent to drug-eluting stent technology. As the field of gene-eluting stents matures it becomes evident that all three main design modules of a gene-eluting stent: a therapeutic transgene, a vector and a delivery system are equally important for accomplishing sustained inhibition of neointimal formation in arteries treated with gene delivery stents. This review summarizes prior work on stent-based gene delivery and discusses the main optimization strategies required to move the field of gene-eluting stents to clinical translation.

  10. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro [Kyoto Second Red Cross Hospital, Kyoto (Japan)

    2012-02-15

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  11. Broncho-vascular fistulas from self-expanding metallic stents: A retrospective case review

    Directory of Open Access Journals (Sweden)

    Chirag Choudhary

    2013-01-01

    Full Text Available To highlight a potentially fatal complication of broncho-vascular fistula arising from the self expanding metallic stent (SEMS placement. We retrospectively analyzed five patients with benign and malignant airway diseases, who developed tracheo/broncho-vascular fistulas following SEMS placement in our tertiary care setting. All patients received either Wallstent or Ultraflex® stent (Boston Scientific, Natick, MA between 1999 and 2007. All patients had received adjunct therapy such as balloon bronchoplasty, laser therapy or electrocautery. Most patients presented with massive hemoptysis. A total of 483 SEMS were placed during this period. SEMS placement can be complicated by Broncho-vascular fistula formation. True incidence and precise time interval between the insertion of stent and onset of this complication is unknown. Additional therapeutic modalities to maintain stent patency may enhance the risk of fistula formation. SEMS should only be used in a select sub-group of patients, after exhaustive evaluation of other treatment options. These cases provide evidence that broncho-vascular fistulas can develop at any time following SEMS placement, suggesting the need for a more cautious approach, especially while using them for a long term management. In benign airway disease, the stent should be removed as soon as healing has taken place.

  12. Thrombolytic therapy followed by stenting for renal artery dissection secondary to blunt trauma.

    Science.gov (United States)

    Lupattelli, Tommaso; Basile, Antonio; Iozzelli, Andrea; Quarenghi, Matteo; Nano, Giovanni; Casana, Renato; Malacrida, Giovanni

    2005-04-01

    A 18-year-old man presented at our clinic with pain in the right flank following a motorbike accident. The diagnosis of renal artery dissection followed by thrombosis was made by computed tomography and confirmed by angiography. Successful revascularization was performed by means of repeated transcatheter injection of small doses of thrombolytic agents within the vessel, followed by deployment of a self-expandable stent. There were no complications, and the patient recovered well. Six months after stent placement, a selective renal angiogram showed excellent flow through the stented portion of the artery and normal parenchyma enhancement in the right kidney.

  13. Management of airway involvement of oesophageal cancer using covered retrievable nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.E. [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Shin, J.H. [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)], E-mail: jhshin@amc.seoul.kr; Song, H.Y. [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Kim, S.B. [Department of Internal Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Kim, K.R.; Kim, J. Hyoung [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2009-02-15

    Aim: To assess the efficacy and safety of covered retrievable nitinol stents in oesophageal cancer patients with airway involvement. Materials and methods: Under fluoroscopic guidance, covered retrievable nitinol airway stents were placed in 23 oesophageal cancer patients with airway stricture and/or oesophagorespiratory fistula (ERF) over a long period of 12 years. Six patients only had aspiration by ERF and three patients had both airway stricture and asymptomatic ERF. Technical aspects, dyspnoea improvement, and/or resolution of ERF symptoms, complications, reinterventions, and survival data were evaluated. Results: A total of 27 airway stents (14 tracheal, 11 bronchial, and two hinged) were placed successfully in 23 patients with airway stricture or ERF. Dyspnoea score decreased significantly after stent placement (p < 0.001). ERF were sealed off in all nine patients. Complications included stent migration or expectoration (n = 4), haemoptysis (n = 2), sputum retention (n = 7), and tumour overgrowth (n = 1). All three migrated stents were easily removed. Twenty-one patients died, with the median survival period of 76 days (range 2-197 days). Conclusion: Placement of covered retrievable expandable nitinol stents was safe and effective for the palliative treatment of airway strictures and/or ERF, with a reasonable range of complications, in patients with advanced oesophageal cancer.

  14. Computational hemodynamics of an implanted coronary stent based on three-dimensional cine angiography reconstruction.

    Science.gov (United States)

    Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C

    2005-01-01

    Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.

  15. Comparison of a nitinol stent versus balloon angioplasty for treatment of a dysfunctional arteriovenous graft

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine/Bucheon St. Mary' s Hospital, Bucheon (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-06-15

    This study aimed to 1) evaluate the outcome of placing a nitinol stent for treating dysfunctional arteriovenous grafts (AVG), and 2) compare the results with those of successful balloon angioplasty. Between February 2008 and October 2011, we retrospectively reviewed the interventional data and medical records of 29 patients (21 men, 8 women; mean age, 67.4 years) who underwent interventional procedures for dysfunctional AVG. Stents were placed only in cases with inadequate angioplasty results. Stent patency was evaluated and compared to cases of successful balloon angioplasty using the Kaplan Meier analysis. Eleven stents and 18 angioplasties were performed successfully at the venous anastomotic site of AVG. The primary patency at 3, 6, 12, and 18 months did not differ significantly for stent placement and angioplasty (52%, 29%, 15%, 15% vs. 71%, 50%, 34%, 34%; mean survival, 164 vs. 253 days, p = 0.283). Secondary patency of the stent also did not differ significantly from angioplasty (80%, 80%, 49%, 49% vs. 76%, 57%, 57%, 36%; mean survival, 405 vs. 385 days, p = 0.553). Nitinol stent placement was effective for treating dysfunctional AVG, but did not improve the primary and secondary patency compared to successful angioplasty.

  16. J-tube technique for double-j stent insertion during laparoscopic upper urinary tract surgical procedures.

    Science.gov (United States)

    Kim, Hyung Suk; Lee, Byung Ki; Jung, Jin-Woo; Lee, Jung Keun; Byun, Seok-Soo; Lee, Sang Eun; Jeong, Chang Wook

    2014-11-01

    Double-J stent insertion has been generally performed during laparoscopic upper urinary tract (UUT) surgical procedures to prevent transient urinary tract obstruction and postoperative flank pain from ureteral edema and blood clots. Several restrictive conditions that make this procedure difficult and time consuming, however, include the coiled distal ends of the flexible Double-J stent and the limited bending angle of the laparoscopic instruments. To overcome these limitations, we devised a Double-J stent insertion method using the new J-tube technique. Between July 2011 and May 2013, Double-J stents were inserted using the J-tube technique in 33 patients who underwent a laparoscopic UUT surgical procedure by a single surgeon. The mean stent placement time was 4.8±2.7 minutes, and there were no intraoperative complications. In conclusion, the J-tube technique is a safe and time-saving method for Double-J stent insertion during laparoscopic surgical procedures.

  17. Influence of high-porosity mesh stent on hemodynamics of intracranial aneu- rysm:A computational study

    Institute of Scientific and Technical Information of China (English)

    邱晓宁; 费智敏; 张珏; 曹兆敏

    2013-01-01

    This paper studies the influence of a High-Porosity Mesh (HPM) stent on the hemodynamic characteristics in the intracra- nial aneurysm based on the Computational Fluid Dynamics (CFD). An idealized basilar tip aneurysm model and a HPM stent model are built. The pulsating blood flow in a cardiac cycle is computationally simulated for non-stented and stented models, to provide a wealth of information of the spatio-temporally varying blood flow field. The influence of the stent placement on the hemodynamic characteristics is analyzed in terms of distributions of velocity, pressure, Wall Shear Stress (WSS) and Energy Loss (EL), which are believed to play an important role in the development and rupture of the aneurysm. The numerical results clearly show that the velo- city, pressure, WSS and EL of the blood flow in the aneurysm are reduced by 30%-40% when the HPM stent is implanted. These computational results may provide valuable hemodynamic information for clinical neurosurgeon.

  18. Complete intraperitoneal displacement of a double J stent: a first case

    Directory of Open Access Journals (Sweden)

    Filippo Maria Turri

    2015-03-01

    Full Text Available Objectives: Ureteral double-J stents are known to migrate proximally and distally within the urinary tract, while perforation and stent displacement are uncommon. Possible mechanisms of displacement are either original malpositioning with ureteral perforation or subsequent fistula and erosion of the excretory system, due to infection or long permanence of the device. We present the unique case of complete intraperitoneal stent migration in a 59-year-old caucasian male without evidence of urinary fistula at the moment of diagnosis, so far an unreported complication. Materials and Methods: Eight months after the placement of a double-J stent for lower right ureteral stricture at a district hospital, the patient came at our observation for urosepsis and hydro-uretero-nephrosis. A CT scan demonstrated intraperitoneal migration of the stent outside the urinary tract. Cystoscopy failed to visualize the lower extremity of the stent, a percutaneous nephrostomy was placed to drain the urinary system and the stent was removed through a small abdominal incision on the right lower quadrant. Results: In our case we presume that during the positioning manoeuvre the guide wire perforated simultaneously the lower ureteral wall and the pelvic peritoneum, and that once the upper end of the stent was coiled, the lower extremity was also attracted intraperitoneally. The lack of pain due to the spinal lesion concurred to this unusual complication. Conclusions: We must be aware that ureteral double J stents may be found displaced even inside the peritoneal cavity, and that the use of retrograde pyelography during placement is of paramount importance to exclude misplacement of an apparently normally coiled upper extremity of the stent.

  19. Randomized controlled trial of pancreatic stenting to prevent pancreatitis after endoscopic retrograde cholangiopancreatography

    Institute of Scientific and Technical Information of China (English)

    Yoshiaki Kawaguchi; Masami Ogawa; Fumio Omata; Hiroyuki Ito; Tooru Shimosegawa; Tetsuya Mine

    2012-01-01

    AIM:To determine the effectiveness of pancreatic duct (PD) stent placement for the prevention of pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP) in high risk patients.METHODS:Authors conducted a single-blind,randomized controlled trial to evaluate the effectiveness of a pancreatic spontaneous dislodgement stent against post-ERCP pancreatitis,including rates of spontaneous dislodgement and complications.Authors defined high risk patients as having any of the following:sphincter of Oddi dysfunction,difficult cannulation,prior history of post-ERCP pancreatitis,pre-cut sphincterotomy,pancreatic ductal biopsy,pancreatic sphincterotomy,intraductal ultrasonography,or a procedure time of more than 30 min.Patients were randomized to a stent group (n =60) or to a non-stent group (n =60).An abdominal radiograph was obtained daily to assess spontaneous stent dislodgement.Post-ERCP pancreatitis was diagnosed according to consensus criteria.RESULTS:The mean age (± standard deviation) was 67.4 ± 13.8 years and the male:female ratio was 68:52.In the stent group,the mean age was 66 ± 13years and the male:female ratio was 33:27,and in the non-stent group,the mean age was 68 ± 14 years and the male:female ratio was 35:25.There were no significant differences between groups with respect to age,gender,final diagnosis,or type of endoscopic intervention.The frequency of post-ERCP pancreatitis in PD stent and non-stent groups was 1.7% (1/60) and 13.3% (8/60),respectively.The severity of pancreatitis was mild in all cases.The frequency of post-ERCP pancreatitis in the stent group was significantly lower than in the non-stent group (P =0.032,Fisher's exact test).The rate of hyperamylasemia were 30% (18/60) and 38.3% (23 of 60) in the stent and non-stent groups,respectively (P =0.05,x2 test).The placement of a PD stent was successful in all 60 patients.The rate of spontaneous dislodgement by the third day was 96.7% (58/60),and the median (range) time to

  20. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels;

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  1. Transient Hemolytic Anemia after Transjugular Intrahepatic Portosystemic Stent Shunt

    OpenAIRE

    Sagrario Garcia-Rebollo; Emilio González-Reimers; Francisco Santolaria-Fernández; Francisco Diaz-Romero; Fermin Rodriguez-Moreno; Antonio Martinez-Riera

    1996-01-01

    Management of variceal bleeding secondary to portal hypertension constitutes a challenging issue, particularly in child's C cirrhotic patients. Recently, transjugular placement of self-expanding metallic stents in the liver (TIPS), creating a shunt between the portal and hepatic branches has provided a safe and promising therapeutic approach in this clinical situation. We report here the case of a 66-year-old male cirrhotic patient who developed a moderately severe clinical picture of a Coomb...

  2. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution

    Science.gov (United States)

    Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart

    2017-01-01

    IMPORTANCE Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. RESULTS There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P < .001). Given the prespecified noninferiority margin of −15%, the

  3. Tracheobronchial stents in children.

    Science.gov (United States)

    Antón-Pacheco, Juan L

    2016-06-01

    Tracheobronchial obstruction is infrequent in children and still remains a challenging matter of concern. Management alternatives vary from conservative treatment to complex surgical techniques or endoscopic interventional procedures. Airway stenting in children is relatively recent and follows the trail of the experience in adult patients. Nevertheless, there are basic differences between both age groups like the benign nature of most obstructions and the small size of the pediatric airway. These specific features raise the issues of the precise role of tracheobronchial stenting in children and the selection of the most adequate device. Stents fall into four main categories according to the material they are made of: metallic, plastic, hybrid, and biodegradable. Each type has its own advantages and drawbacks so the ideal stent is not yet available. Despite increasing experience with stenting, definite clinical criteria for their use in children are yet to be established. Even so, there seems to be a basic general agreement that stents may play a role in particular clinical settings in which there are no other therapeutic options. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. A new patient safety smartphone application for prevention of "forgotten" ureteral stents: results from a clinical pilot study in 194 patients.

    Science.gov (United States)

    Molina, Wilson R; Pessoa, Rodrigo; Donalisio da Silva, Rodrigo; Kenny, McCabe C; Gustafson, Diedra; Nogueira, Leticia; Leo, Mark E; Yu, Michael K; Kim, Fernando J

    2017-01-01

    Approximately 12% of all ureteral stents placed are retained or "forgotten." Forgotten stents are associated with significant safety concerns as well as increased costs and legal issues. Retained ureteral stents (RUS) often occur due to lack of clinical follow-up, communication or language barriers, and economic concerns. We describe a multiplatform application that facilitates data collection to prevent RUS. The "Stent Tracker" application can be installed on mobile devices and computers. The encrypted and password-protected information is accessible from any device and provides information about each procedure, stent placement and removal dates, as well as product description. This multicenter retrospective study included 194 patients who underwent stent placement between July and October 2015. Nominal data was tallied and ordinal data was divided into quartiles of 25, 50, and 75%. A total of 194 patients from three institutions underwent ureteral stent placement. Reasons for stent placement include 122 cases post ureteroscopy (63%), 8 cases post percutaneous nephrolithotomy (PCNL) (4%), 14 cases post extracorporeal shock wave lithotripsy (SWL) (7%), 18 cases of cancer-related ureteral obstruction (9%), 21 cases of hydronephrosis (11%), and 11 for other reasons (6%). Of these patients, only one patient was lost to follow-up (0.5%). On average, ureteral stents were removed within 14 days of placement (IQR: 8-26 days). The "Stent Tracker" is a patient safety application that provides a secure and simplified interface, which can significantly reduce the incidence of RUS. Further developments could include automated notifications to patients and staff, color-coding, and integrated information with electronic patient charts.

  5. Angioplasty and stent treatment of transplant renal artery stenosis.

    Science.gov (United States)

    Del Pozo, Maitane; Martí, Jordi; Guirado, Lluís; Facundo, Carme; Canal, Cristina; de la Torre, Pablo; Ballarín, José; Díaz, Joan M

    2012-07-17

    Transplant renal artery stenosis is a major complication that requires a therapeutic approach involving surgery or angioplasty. The aim of this study was to analyse the evolution of renal transplant patients with renal allograft artery stenosis treated by angioplasty and stent placement. Thirteen patients were diagnosed with transplant renal artery stenosis. Clinical suspicion was based on deterioration of renal function and/or poorly controlled hypertension with compatible Doppler ultrasound findings. The diagnosis was confirmed by arteriography, performing an angioplasty with stent placement during the same operation. A progressive improvement in renal function was observed during the first 3 months after the angioplasty, and renal function then remained stable over 2 years. In addition, blood pressure improved during the first 2 years, and as a consequence there was no need to increase the average number of anti-hypertensive drugs administered (2.5 drugs per patient). In conclusion, angioplasty with stent placement is a safe and effective procedure for the treatment of transplant renal artery stenosis.

  6. Doxazosin oral intake therapy to relieve stent - related urinary symptoms and pain: a prospective, randomized, controlled study

    Directory of Open Access Journals (Sweden)

    Long Zhang

    Full Text Available ABSTRACT Objective: To assess the impact of Doxazosin Oral Intake Therapy on urinary symptoms and pain in patients with indwelling ureteral stents Patients and Methods: A total of 239 patients with ureteral stone-related hydronephrosis who underwent a double-J stent insertion after ureteroscopic lithotripsy were enrolled. Patients were randomized to receive doxazosin cotrolled release 4 mg once daily for 4 weeks or matching placebo. Patients completed the brief-form Chinese version Ureteric Stent Symptom Questionnaire (USSQ and quality of life (QoL score 2 weeks and 4 weeks after stent placement and 4 weeks after stent withdrawal. The analgesic use was also recorded during the stenting period. Results: Patients in Doxazosin Oral Intake Therapy group, in the first 2 weeks and second 2 weeks with the stent in situ, expressed significant lower daytime frequency (p=0.028 and p=0.038, nocturia (p=0.021 and p=0.008 and urgency (p=0.012 and p=0.014, respectively. Similarly, flank pain score, QoL score and analgesic use were also significant less in the stenting period. There was no significant difference in scores of urinary symptoms, pain and QoL during the post-stent period between two cohorts. Conclusions: Doxazosin Oral Intake Therapy reduced stent-related urinary symptoms, pain and the negative impact on QoL.

  7. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  8. Stent Fracture after Everolimus-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali S. Almasood

    2011-01-01

    Full Text Available Compared with bare-metal stents, drug-eluting stents (DES have greatly reduced the risk of in-stent restenosis (ISR by inhibiting neointimal growth. Nevertheless, DES are still prone to device failure, which may lead to cardiac events. Recently, stent fracture (SF has emerged as a potential mechanism of DES failure that is associated with ISR. Stent fracture is strongly related to stent type, and prior reports suggest that deployment of sirolimus eluting stents (SES may be associated with a higher risk of SF compared to other DES. Everolimus eluting stents (EESs represent a new generation of DES with promising results. The occurrence of SF with EES has not been well established. The present paper describes two cases of EES fracture associated with ISR.

  9. Nanomaterial coatings applied on stent surfaces.

    Science.gov (United States)

    Bagheri, Mahsa; Mohammadi, Marzieh; Steele, Terry Wj; Ramezani, Mohammad

    2016-05-01

    The advent of percutaneous coronary intervention and intravascular stents has revolutionized the field of interventional cardiology. Nonetheless, in-stent restenosis, inflammation and late-stent thrombosis are the major obstacles with currently available stents. In order to enhance the hemocompatibility of stents, advances in the field of nanotechnology allow novel designs of nanoparticles and biomaterials toward localized drug/gene carriers or stent scaffolds. The current review focuses on promising polymers used in the fabrication of newer generations of stents with a short synopsis on atherosclerosis and current commercialized stents, nanotechnology's impact on stent development and recent advancements in stent biomaterials is discussed in context.

  10. Metallic Stents for Proximal Tracheal Stenosis: Is It Worth the Risk?

    Directory of Open Access Journals (Sweden)

    Sandeep Bansal

    2012-01-01

    Full Text Available Objective. To demonstrate the risk associated with blocked proximal tracheal stents when a patient presents with acute respiratory distress, with blockage of stent and what is the best management we can offer without damage to the stent and its associated complications. Case Report. A 22-yr-old, male patient, presented in severe respiratory distress. He had history of corrosive poisoning for which he was tracheotomised. A stainless steel wire mesh stent was placed in the trachea, from the subglottis, to just above the carina. One month later, he presented with a critically compromised airway with severe respiratory distress. Emergency tracheostomy was done and the metallic stent had to be cut open, in order to provide an airway. Conclusion. Management of blocked proximal stents with patient in respiratory distress remains a challenge. Formation of granulation tissue is common and fibreoptic bronchoscopic assisted intubation may not always be possible. A regular follow up of all patients with stents is essential. Placement of stents within a few centimetres of cricotracheal junction should not be encouraged for long term indications.

  11. Cobalt chromium stents versus stainless steel stents in diabetic patients

    Directory of Open Access Journals (Sweden)

    Mahmoud Ahmed Tantawy

    2014-03-01

    Conclusions: We concluded that no significant statistical difference was found between the two stents (cobalt-chromium alloy bare metal stent versus conventional bare metal stainless steel stent in diabetic patients regarding (initial procedural success, in-hospital complications, the incidence of ISR at follow up, event-free survival at follow up.

  12. Bilateral ophthalmoplegia and exophthalmos complicating central hemodialysis catheter placement.

    Science.gov (United States)

    Varelas, P N; Bertorini, T E; Halford, H

    1999-05-01

    We describe a 58-year-old woman who presented with bilateral ophthalmoplegia, exophthalmos, and headache and was found to have retrograde internal jugular vein flow secondary to a high-grade obstruction of the ipsilateral brachiocephalic vein from a previous hemodialysis catheter placement. The patient had also a high-flow dialysis graft in the ipsilateral arm. The cranial and extracranial venous system congestion resolved, and the signs disappeared soon after a balloon angioplasty and stent placement at the level of the obstruction.

  13. Primary stenting of occluded native coronary arteries: final results of the Primary Stenting of Occluded Native Coronary Arteries (PRISON) study.

    Science.gov (United States)

    Rahel, Braim M; Suttorp, Maarten J; Laarman, Gert J; Kiemeneij, Ferdinand; Bal, Egbert T; Rensing, Benno J; Ernst, Sjef M P G; ten Berg, Jurriën M; Kelder, Johannes C; Plokker, H W Thijs

    2004-05-01

    Primary intracoronary stent placement after successfully crossing chronic total coronary occlusions may decrease the high restenosis rate at long-term follow-up compared with conventional balloon angioplasty. In a prospective, randomized trial, balloon angioplasty was compared with stent implantation for the treatment of chronic total occlusions. Patients were followed for 12 months with angiographic follow-up at 6 months. Quantitative coronary analysis was performed by an independent core lab. A total of 200 patients were enrolled. Baseline characteristics were evenly distributed. After the procedure the mean minimal luminal diameter in the conventional group was 2.34 +/- 0.46 mm versus 2.90 +/- 0.41 mm in the stented group (P 50% diameter stenosis) was seen in 33% in the conventional group versus 22% in the stented group (P =.137). The reocclusion rates were 7.3% and 8.2%, respectively (P = 1.00). At 12 month follow-up, the rate of target lesion revascularization was significantly higher in the conventional group (29% versus 13%, P <.0001). These data demonstrate that stenting of chronic total occlusions is superior to balloon angioplasty alone with a statistically significant reduction in the need for target lesion revascularization and a lower, but not significant, restenosis rate.

  14. Metallic stents for airway complications after lung transplantation: long-term follow-up.

    Science.gov (United States)

    Abdel-Rahman, Nader; Kramer, Mordechai R; Saute, Milton; Raviv, Yael; Fruchter, Oren

    2014-05-01

    Bronchial stenosis is still a significant source of morbidity and mortality following lung transplantation (LTX) and often mandating placement of a bronchial stent. It has been suggested that although self-expanding metal stents offer excellent early palliation, their long-term complication rates are unacceptably high, and hence, their usage in many transplantation centres has been nearly abandoned. The aim of the study was to assess short- and long-term complication rates and survival in LTX patients with bronchial stenosis treated with insertion of self-expanding metal stents. From January 1997 to March 2013, 435 patients underwent LTX (325 single-LTX and 110 bilateral LTX). Of 503 actual anastomoses at risk (derived by subtracting the number of anastomoses in 30 patients who died within 30 days of LTX), 60 airway complications (11.9%) in 47 patients required self-expanding metal stent insertion. We assessed the early results and long-term outcomes and survival compared with LTX patients in whom stents were not required. The median follow-up period ranged from 1 to 132 (median 54) months. Immediate relief of symptoms was achieved in the vast majority of patients (95%). One-, three- and five-year survival in patients who required self-expanding metal stent placement were 77.7, 66.6 and 55.5%, respectively. The corresponding survival rates in LTX patients without stents were 69, 64.9 and 61.1% (P > 0.05). Self-expanding metal stents are safe and effective tools in the management of airway complications post-LTX and provide immediate improvement in symptoms and pulmonary function tests in the vast majority of cases. The long-term complication rate is low, and mortality is similar to that in LTX patients who did not require stent insertion.

  15. Horizontal stent-assisted coil embolisation of wide-necked intracranial aneurysms with the Enterprise stent - a case series with early angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, Mohammed Aslam; Bhattacharya, Joti J.; Jenkins, Sarah [Institute of Neurological Sciences, Southern General Hospital, Department of Neuroradiology, Glasgow (United Kingdom); Lindsay, Kenneth W. [Institute of Neurological Sciences, Southern General Hospital, Department of Neurosurgery, Glasgow (United Kingdom)

    2009-06-15

    The purpose of the study is to describe our experience in eight cases of horizontal stenting across the circle of Willis in patients with terminal aneurysms. Eight patients were treated with horizontal stent placement and aneurysm coiling. All aneurysms had highly unfavourable dome to neck ratios. All patients were followed up with digital subtraction angiography at 3-12 months following treatment. The Enterprise stent was successfully deployed horizontally in vessels of less than 2-mm diameter with no stent occlusion. Neurological complications occurred in one patient. Immediate and follow-up angiographic results were encouraging with six stable occlusions at 6 months. There was one asymptomatic case of in-stent stenosis and one case of late organised in-stent thrombus. Horizontal deployment of the Enterprise stent to assist coil embolisation of wide-necked terminal aneurysms is feasible. This device can be navigated via relatively small communicating arteries, in cases with favourable anatomy. Early angiographic results were favourable; however, longer-term follow-up will be required. (orig.)

  16. Percutaneous stenting of the superior mesenteric artery for the treatment of chronic mesenteric ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun [Yongdong Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Do Yun [Yonsei National College of Medicine, Seoul (Korea, Republic of); Kim, Sam Soo [Kangwon National University Hospital, Chuncheon (Korea, Republic of)

    2008-06-15

    We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients.

  17. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  18. Primary stenting in the treatment of focal atherosclerotic abdominal aortic stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, W.; Falkowski, A.; Garncarek, J.; Karasek, M.; England, S.; Zawierucha, D

    2006-08-15

    Aim: To evaluate the results of primary stent placement in focal atherosclerotic aortic stenoses using balloon expandable stents. Materials and methods: Twenty-six primary balloon expandable stent placements in the abdominal aorta were performed and reviewed. All the aortic stenoses were atherosclerotic. Patients were followed up by ankle/brachial pressure indices (ABPI) and Doppler ultrasound (US) at 24 h after procedure and at 12 and 24 months. Follow-up angiograms were performed at 12 months. Results: Twenty-six stents in 26 patients were placed in the infrarenal aorta. All procedures were technically successful and immediate clinical success was obtained. The mean ABPI significantly improved from 0.52 {+-} 0.10 to 0.94 {+-} 0.09 within 24 h after procedure, and remained at 0.90 {+-} 0.12 between 12 and 24 months follow-up (mean 18 months). There was full haemodynamic success at hospital discharge and at 12 and 24 months after the procedure. Clinical success at 12 and 24 months (mean 18 months) was defined as an improvement in the Fontaine classification by at least one class compared with the pre-procedure class and was shown to be 100%. Conclusion: In summary, we report that primary stenting is a safe and effective alternative to surgery in cases of symptomatic stenosis of the infrarenal abdominal aorta. The excellent intermediate term results suggested that we would recommend primary stenting as the treatment of choice for focal atherosclerotic stenoses of the infrarenal aorta in selected patients.

  19. Temporary Rectal Stenting for Management of Severe Perineal Wounds in Two Dogs.

    Science.gov (United States)

    Skinner, Owen T; Cuddy, Laura C; Coisman, James G; Covey, Jennifer L; Ellison, Gary W

    Perineal wounds in dogs present a challenge due to limited local availability of skin for closure and constant exposure to fecal contaminants. This report describes temporary rectal stenting in two dogs following severe perineal wounds. Dog 1 presented with a 4 × 4 cm full-thickness perineal slough secondary to multiple rectal perforations. A 12 mm internal diameter endotracheal tube was placed per-rectum as a temporary stent to minimize fecal contamination. The stent was removed 18 days after placement, and the perineal wound had healed at 32 days post-stent placement, when a minor rectal stricture associated with mild, intermittent tenesmus was detected. Long-term outcome was deemed good. Dog 2 presented with multiple necrotic wounds with myiasis, circumferentially surrounding the anus and extending along the tail. A 14 mm internal diameter endotracheal tube was placed per-rectum. The perineal and tail wounds were managed with surgical debridement and wet-to-dry and honey dressings prior to caudectomy and negative pressure wound therapy (NPWT). Delayed secondary wound closure and stent removal were performed on day six without complication. Long-term outcome was deemed excellent. Temporary rectal stenting may be a useful technique for fecal diversion to facilitate resolution of complex perineal injuries, including rectal perforation.

  20. Interventional Management of Delayed and Massive Hemobilia due to Arterial Erosion by Metallic Biliary Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hee Seok [Dept. of Radiology, Gyeongsang National University Hospital, Jinju (Korea, Republic of); Shin, Tae Beom [Dept. of Diagnostic Radiology, Kimhae Jung Ang Hospital, Kimhae (Korea, Republic of); Hwang, Jae Cheol [Dept. of Radiology, Ulsan Hospital, Ulsan (Korea, Republic of); Bae, Jae Ik [Dept. of Radiology, Ajou University Hospital, Suwon (Korea, Republic of); Kim, Chang Won [Dept. of Radiology, Busan National University Hospital, Busan (Korea, Republic of)

    2012-01-15

    To evaluate the effectiveness of interventional management for delayed and massive hemobilia secondary to arterial erosion self expandable metallic stent (SES) in with biliary duct malignancy. Over 8-year period, eight patients who suffered from delayed massive hemobilia after SES placement for malignant biliary obstruction as palliative procedure, were included. The mean period between SES placement and presence of massive gastrointestinal hemorrhage was 66.5 days (15-152 days), pancreatic cancer (n = 2), Klatskin tumor (n = 2), common bile duct cancer (n = 2), intrahepatic cholangiocarcinoma (n = 1), and gastric cancer with ductal invasion (n = 1). Angiographic findings were pseudoaneurysm (n = 6), contrast extravasation (n = 1) and arterial spasm at segment (n = 1). Six patients underwent embolization of injured vessels using microcoils and N-butyl cyanoacrylate. Two patients underwent stent graft placement at right hepatic artery to prevent ischemic hepatic damage because of the presence of portal vein occlusion. Massive hemobilia was successfully controlled by the embolization of arteries (n = 6) and stent graft placement (n = 2) without related complications. The delayed massive hemobilia to arterial erosion metallic biliary stent is rare this complication be successfully treated by interventional management.

  1. Effective Endovascular Stenting of Malignant Portal Vein Obstruction in Pancreatic Cancer

    Directory of Open Access Journals (Sweden)

    Christian M. Ellis

    2009-01-01

    Full Text Available We report herein the case of a patient successfully treated by transhepatic portal venous stent placement for malignant portal vein obstruction with associated gastric and small bowel varices and repeated gastrointestinal bleeding. CT angiography and portography showed severe portal vein obstruction from recurrent pancreatic cancer 15 months following pancreaticoduodenectomy with tumor encasement and dilated collateral veins throughout the gastric and proximal small bowel wall as the suspected cause of the GI bleeding. Successful transhepatic endovascular stent placement of the splenic vein at the portal vein confluence followed by balloon dilation was performed with immediate decompression of the gastric and small bowel varices and relief of GI hemorrhage in this patient until his death four months later. The treatment for patients with this dilemma can prove to be difficult, but as we have shown endovascular stenting of the portal system is an effective treatment option.

  2. A Comparison of Y-Type and T-Type Metallic Bilateral Biliary Stents in Patients with Malignant Hilar Biliary Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Esther; Jin, Gong Yong; Hwang, Seung Bae; Choi, Eun Jung; Song, Ji Soo; Han, Young Min; Kwon, Keun Sang [Dept. of Chonbuk National University Hospital and Medical School, Jeonju (Korea, Republic of)

    2013-04-15

    To compare the Y type (side-by-side) and T type (stent-in-stent) bilateral biliary metal stenting in malignant hilar obstruction in terms of treatment outcomes, including post-stenting serum bilirubin level and stent patency. 41 consecutive patients with advanced hilar malignancies who underwent percutaneous placement of bilateral metallic stents - Y (n = 23) and T types (n = 18) - were retrospectively reviewed. We evaluated stent patency after the procedure by cholangiogram and abdominal CT. Pre- and post-stenting serum bilirubin level (total, direct bilirubin) at 1 week and at 1 month were compared. Student t-test and Kaplan-Meier method were used in the statistical analysis. After comparing the median stent patency according to both types, they did not differ significantly (Y: 38 days, T: 61 days; p 0.141). There was a more decrease in the total and direct bilirubin of the T type compared to the Y type after 1 week (p = 0.013, 0.025). However, no significant difference existed between the decreasing bilirubin rates of both types after 1 month (p = 0.923, 0.742). In patients with malignant hilar obstruction, both Y and T type bilateral metallic biliary stents are effective methods. Stent patency and bilirubin decrease rates were not significantly different.

  3. Drug-eluting stents: current issues

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); A.T.L. Ong (Andrew)

    2005-01-01

    textabstractEarly stent thrombosis occurs in about 1% to 1.5% of patients with drug-eluting stents, very similar to the rate with bare-metal stents. Late stent thrombosis is more of a concern with drug-eluting stents, with an incidence of at least 0.35%. I would urge caution if you feel you have to

  4. Drug-eluting stents: current issues

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); A.T.L. Ong (Andrew)

    2005-01-01

    textabstractEarly stent thrombosis occurs in about 1% to 1.5% of patients with drug-eluting stents, very similar to the rate with bare-metal stents. Late stent thrombosis is more of a concern with drug-eluting stents, with an incidence of at least 0.35%. I would urge caution if you feel you have to

  5. Expandable metallic stents in the palliative treatment of malignant tracheobronchial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Woong; Jung, Gyoo Sik; Kim, Seong Min; Lee, Seung Ryong; Kim, Hyun Sook; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-05-01

    The purpose of this study is to report the outcome of using expandable metallic stent in the management of malignant tracheobronchial stenosis with dyspnea. Under fluoroscopic and bronchoscopic guidance, seven patients with malignant airway stenosis were treated with ten expandable metallic stents. The cause of stenosis was metastasis from esophageal cancer in five patients, recurrent adenoid cystic carcinoma of the trachea in one, and primary lung cancer in one. The major sites of obstruction were the trachea in four patients, the left main bronchus in one, the trachea and left main bronchus in one, and the trachea and both bronchi in one. Chest radiography (n=7), bronchoscopy (n=5), pulmonary function test (PFT)(n=3), and spirometry(n=1) were performed before and after stent placement. In all seven patients, the stent was successfully placed at the lesion sites and dyspnea began to improve immediately. After the procedure, chest radiography and bronchoscopy showed an increase in airway diameter. After the procedure, chest radiography and bronchoscopy showed an increase in airway diameter. After stent placement, forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) improved 53% and 56%, respectively. Peak flow velocity also changed from 46 L/min to 200 L/min. During median follow-up of 67 (41-1565) days, one stent migration occurred. In one patient, proximal tumor overgrowth occurred, and in one, tumor ingrowth was treated with balloon dilatation. For in the palliative treatment of malignant tracheobronchial stenosis with dyspnea, placement of expandable metal stents is safe and effective. (author). 21 refs., 1 tabs., 3 figs.

  6. [Physical properties of Strecker stents].

    Science.gov (United States)

    Okuda, Y; Sawada, S; Morioka, N; Kodani, K; Ihaya, T; Tanigawa, N; Kobayashi, M; Hashimoto, M; Oouchi, Y; Shimatani, Y

    1995-02-01

    Strecker stent is a balloon-expandable metallic stent that is made of knitted tantalum wire mesh in order to Maintain flexibility. Therefore, the prosthesis is well suited to irregular and tortuous tube organs. We performed several physical experiments using 8 mm and 6 mm diameter stents made of 0.1 mm diameter wire filament. The bearing power of the 8 mm diameter stent against the circumferential compression pressure was divided into two groups, that is, 77-100% and under 66% of expansile rate. The capacity bearing the circumferential compression pressure of the latter group was greater than that of the former. Further, the bearing power of the 6 mm diameter stent was greater than that of the 56% expansile rate of the 8 mm diameter stent. The smaller the expansile rate of the stent, the smaller the minimum radius of curvature within the limits of the stent's plastic. To evaluate the suitability of the stent in clinical use, we made two projections on the inner surface of rubber tubes, and the stents were placed into the rubber tubes at different expansile rates. We evaluated the degree of contact of the stents against the rubber wall by taking soft X-ray photographs. The stents showed good suitability under the condition of incomplete expansion. For the above reasons, we concluded that, from the view-point of bearing power, the stent should be placed in the full expansile state. From the viewpoint of contact against the vessel wall, the stent should be placed in the incomplete expansile state.

  7. "Squid-capture" modified in situ stent-graft fenestration technique for aortic arch aneurysm repair.

    Science.gov (United States)

    Hongo, Norio; Miyamoto, Shinji; Shuto, Rieko; Wada, Tomoyuki; Kamei, Noritaka; Sato, Aiko; Matsumoto, Shunro; Kiyosue, Hiro; Mori, Hiromu

    2014-08-01

    An 83-year-old female was found to have an fusiform aneurysm in the aortic arch. She was deemed to be a high surgical risk; therefore, endovascular stent-graft placement followed by revascularization of the brachiocephalic trunk using in situ stent-graft fenestration was considered. However, the safe application of fenestration was deemed difficult due to the tortuosity of the brachiocephalic artery. The patient was successfully treated with the aid of the "squid-capture" technique, which consists of deployment of the stent-graft in a snare wire loop that was advanced from the brachiocephalic artery and fenestration of the stent-graft with the support of the loop. A follow-up exam revealed complete sealing of the aneurysm without any complications. The squid-capture technique allows for the safe and secure puncture of the graft.

  8. A newly designed Y-shaped covered stent in the palliative treatment of hepatic hilar malignant obstruction: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Chul; Lee, So Won [Dept. of Radiology, Mokdong Hospital, Ewha Womans University College of Medicine, Seoul (Korea, Republic of); Chung, Hwan Hoon [Dept. of Radiology, Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2013-01-15

    We report a case in an inoperable patient with the hilar malignant biliary obstruction treated palliatively by the use of a newly designed Y-shaped covered stent without interfering contra-lateral bile duct. We percutaneously inserted a newly designed Y-shaped covered stent into a biliary tree in an inoperable patient with Bismuth Type II cholangiocarcinoma. We checked tubograms, enhanced CT studies, and blood bilirubin levels before, one week after, and at every three month after the stenting, by observing closely the signs of clinical infection as well. The follow-up period was about 12 months. The placement of the Y-shaped covered stent was successful and resulted in adequate biliary drainage in the immediate post-procedural tubogram and in the follow-up abdominal CT. The serum bilirubin levels did not show elevation after the insertion of the Y-shaped covered stent.

  9. Tests for Colorectal Cancer

    Science.gov (United States)

    ... Cancer Early Detection, Diagnosis, and Staging Tests for Colorectal Cancer Colorectal cancer is often found after symptoms appear, ... Report: Colon Pathology. Imaging tests to look for colorectal cancer Imaging tests use sound waves, x-rays, magnetic ...

  10. A retrievable rescue stent graft and radiofrequency positioning for rapid control of noncompressible hemorrhage.

    Science.gov (United States)

    Chun, Youngjae; Cho, Sung Kwon; Clark, William C; Wagner, William R; Gu, Xinzhu; Tevar, Amit D; McEnaney, Ryan M; Tillman, Bryan W

    2017-08-01

    Noncompressible hemorrhage of the torso remains a challenging surgical dilemma. Stent graft repair requires endovascular expertise, imaging, and inventory that are not available within the critical window of massive hemorrhage. We developed a retrievable stent graft for rapid hemorrhage. We further investigated a radiofrequency (RF) positioning approach as a possible alternative to the logistics of fluoroscopy. A retrievable stent graft was constructed with a novel "petal and stem" design from nitinol and covered with a sleeve of electrospun polyurethane. The stent graft was tested using an in vitro model of simulated hemorrhage. Next, the stent graft was examined in vivo using a porcine model of noncompressible hemorrhage. The stent was examined for hemorrhage control in a porcine model of either aortic or caval injury. An RF reader was assembled from an Arduino processor while RF tags were affixed to the ends of the stent graft. Detection accuracy of a handheld RF wand for an RF tag was quantified both in vitro and through tissue. The retrievable RESCUEstent graft was deployed within minutes and rapidly controlled traumatic hemorrhage angiographically in both aortic injury (n = 3) and caval injury (n = 2). Stent grafts were easily recaptured in both models in under 15 seconds. The LED light of a handheld RF detector illuminated when positioned directly over an RF tag. The RF detection approach revealed positioning accuracy to within 1 cm of the intended target, despite tissue interference. This study demonstrates the rapid deployment and retrieval of a RESCUE stent graft as well as the ability to tamponade injuries of the aorta and cava. In addition, this study demonstrates the feasibility of RF tags to guide stent placement through tissue. More rigorous models are needed to define the effectiveness of this approach in the setting of vascular injury and shock.

  11. Transurethral exchange of double-J ureteral stent using goose- neck snare

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chang Ho; Kim, Yun Hwan; Cho, Sung Bum; Kim, Chul Joong; Kim, Hyoung Rae; Kim, Hong Weon; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Cho, Sung Bum [Eulji Hospital, Eulji College of Medicine, Taejon (Korea, Republic of)

    2000-09-01

    To evaluate the usefulness of transurethral exchange of double-J ureteral stent as an effective alternative to the cystoscopic approach. There were 20 exchange cases involving seven patients (six women and one man) who initially underwent anterograde manipulation of a double-J ureteral stent. Indications for stent placement were ureteral stricture caused by malignancy in six patients (cervical carcinoma (n=3D5), stomach carcinoma (n=3D1)), and renal tuberculosis in one. An 8-F Nelaton catheter was inserted in the bladder via the urethra and contrast material was injected until the bladder was fully distended. The distal end of a double-J ureteral stent was extracted to the urethral orifice using a goose-neck snare and a 0.035{sup s}tiff guide wire was then advanced to the renal pelvis through the stent. After that, the stent was removed and a 4-F Cobra catheter was advanced to the renal pelvis along the guide wire. Contrast material was injected through the catheter, and the renal pelvis, calyx and ureter were opacified. The 0.035 stiff guide wire was again inserted via the catheter, and a new double-J ureteral stent was inserted, and the catheter removed. Finally, the new double-J stent was properly located within the renal pelvis and the bladder. Double-J ureteral stents were successfully exchanged in 19 of 20 exchange cases. After the procedure, all patients reported tolerable, minimal lower abdominal pain. Transurethral exchange of double-J ureteral stent is a useful alternative to cystoscopy. (author)

  12. Endovascular Treatment of Chronic Mesenteric Ischemia by Crossing of Two Stents in a Patient with Celiacomesenteric Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Khil, Eun Kyung; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2013-06-15

    A 73-year-old woman was presented with a 3-month history of postprandial abdominal pain and weight loss. The patient had an anatomic variant of celiacomesenteric trunk (CMT), with complete occlusion of the superior mesenteric artery (SMA) and significant stenosis of the CMT ostium, resulting in chronic mesenteric ischemia. After several unsuccessful attempts at revascularization of the SMA, celiac artery stenting was performed, followed by SMA stent placement through the previously placed stent mesh into the occlusion site. The patient's symptoms completely resolved after treatment.

  13. Long-term indwelling double-J stents: Bulky kidney and urinary bladder calculosis, spontaneous intraperitoneal perforation of the kidney and peritonitis as a result of 'forgotten' double-J stent

    Directory of Open Access Journals (Sweden)

    Stojković Ivica

    2009-01-01

    Full Text Available Background. The first double-J (DJ stents were manufactured in 1978. Their J-shaped tips efficiently prevent their migration from kidneys and from the urinary bladder. Nowadays, DJ stents are in common use because they provide efficient and relatively safe urinary derivation between the kidney and the urinary bladder. We report this case with the aim to point out possible serious complications with long-term indwelling stents. Case report. The patient was admitted to hospital five years after the placement of DJ in a bad general condition, with symptoms of peritonitis. Radiological examination (plain abdominal film, computerized tomography, excretory urogram and cystography showed bulky calculosis at each tip of the stent, affunctional right kidney, vesicoureteral reflux through the DJ stent and ureter all the way to the right kidney, as well as a large amount of turbid liquid in the abdomen. In the course of the operation, the bulky stone with the DJ stent was removed form the urinary bladder, followed by a large amount of turbid liquid extracted from the abdomen. During adhesiolysis, a small intraperitoneal perforation through which a tip of the stent prolapsed, was found on the upper pole of the kidney. After that, nefrectomy was performed. The patient was discharged 18 days after the surgery. Conclusion. There are usually no complications with shortterm DJ stent urinary drainage. However, indwelling DJ stents can cause serious complications, such as migration, incrustration and fragmentation. DJ indwelling should be as short as possible. If indwelling stenting is necessary, the DJ stent should be replaced with a new one in due time, or another kind of derivation should be performed. Careful monitoring of patients could exclude any possibility of a stent being forgotten at all.

  14. Initial experience with live three-dimensional image overlay for ductal stenting in hypoplastic left heart syndrome.

    Science.gov (United States)

    Goreczny, Sebastian; Morgan, Gareth J; Dryzek, Pawel; Moll, Jadwiga A; Moszura, Tomasz

    2016-12-20

    Precise visualisation of ductal morphology and adjacent vessels is crucial for accurate stent choice and placement during hybrid palliation of hypoplastic left heart syndrome (HLHS). We aimed to describe our initial experience with live three-dimensional reconstruction overlay derived from rotational angiography (RA) for ductal stenting in HLHS. We carried out a retrospective review of ductal stenting in 18 newborns with HLHS, including six patients with 3D reconstruction overlay used to guide the intervention. The median age at the intervention was 20 days (range 13-31 days) and the median weight was 3.25 kg (range 3-4 kg). Eleven RA runs were performed, pre and post stent implantation in five patients and before the intervention in one patient. 3D reconstructions from all RA runs had sufficient image quality to allow stent placement without additional contrast injections. Comparison with 2D angiography-guided ductal stenting showed similar contrast usage, with the 2D angiography patients receiving a higher radiation dose. Three-dimensional rotational angiography provides accurate visualisation of the ductal morphology and nearby structures. Three-dimensional reconstruction overlay with clear landing points enabled precise stent implantation with no additional contrast injections and lower radiation doses than conventional angiography in our patients.

  15. COMBINED INTRAOPERATIVE ILIAC ARTERY STENTS AND FEMORO-POPLITEAL BYPASS FOR MULTILEVEL ATHEROSCLEROTIC OCCLUSIVE DISEASE

    Institute of Scientific and Technical Information of China (English)

    刘昌伟; 管珩; 李拥军; 郑曰宏; 刘卫

    2001-01-01

    Objective. To review our preliminary experience and evaluate our early results of a combined intraoperative iliac angioplasty and stenting with infrainguinal revascularization in multilevel atherosclerotic occlusive disease.``Methods. From July 1999 to April 2000, intraoperative iliac angioplasty and stenting combined with simultaneous femoro-popliteal bypass were performed on 12 lower extremities of 10 patients suffering from multilevel atherosclerotic occlusive disease. There were 8 men and 2 women, average 72 years. The indications for procedures included disabling claudication in 3 and rest pain in 7 patients.``Results. Eleven iliac angioplasty and stent procedures combined with simultaneous 9 femoro-popliteal bypass and 3 femoro-femoral-popliteal bypass were performed in 12 limbs of 10 patients. Angioplasty and stent placement was technically successful in all patients. One contralateral femoral-popliteal bypass was failure after femorofemoral-popliteal bypass. There were no additional instances of procedural or postoperative morbidity or mortality. Mean follow-up was 5 months (range 1 ~ 10 months). During the follow-up period, one femoro-infrapoplitealgraft became occluded after 7 months and above-knee amputation was required. The cumulative primary patency rate of stented iliac arteries, femoro-femoral bypass grafts and femoro-popliteal bypass grafts were 100% ( 11 /11), 100% (3/3) and 90. 9% (10/11) in the follow-up period, respectively. The amputation rate was 8.3%(1/12).``Conclusions. Intraoperative iliac artery PTA and stent placement can be safely and effectively performed simultaneously with infrainguinal revascularization for multilevel atherosclerotic occlusive disease by skilled vascular surgeon, using a prtable C arm fluoroscopy in the operating room. Furthermore, iliac artery PTA and stenting was valuable adjunct to distal bypass either to improve inflow and outflow, or to reduce the extent of traditional surgical intervention, and also, any

  16. Percutaneous treatment of superior vena cava syndrome using metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma [Department of Interventional Radiology, ' ' Lozano Blesa' ' University Hospital, Avda. San Juan Bosco 15, 50009 Zaragoza (Spain); Gamboa, Pablo [Division of Interventional Radiology, Ohio State University Hospital, Columbus, Ohio (United States); Tobio, Ricardo [Interventional Radiology, Clinica de la Zarzuela, Madrid (Spain); Herrera, Marcos [Division of Interventional Radiology, University of Minnesota, Minneapolis, Minnesota (United States)

    2003-04-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  17. Laparoscopic common bile duct exploration and antegrade biliary stenting: Leaving behind the Kehr tube

    Directory of Open Access Journals (Sweden)

    Darío Martínez-Baena

    2013-03-01

    Full Text Available Introduction: single-stage laparoscopic surgery of cholelithiasis and associated common bile duct stones (CL-CBDS has shown similar results when compared to laparoscopic cholecystectomy combined with ERCP. Classically, choledochorrhaphy has been protected by a T-tube drain to allow external bypass of bile flow. However, its removal is associated with a significant complication rate. Use of antegrade biliary stents avoids T-tube removal associated morbidity. The aim of this study is to compare the results of choledochorrhaphy plus T-tube drainage versus antegrade biliary stenting in our series of laparoscopic common bile duct explorations (LCBDE. Material and methods: between 2004 and 2011, 75 patients underwent a LCBDE. Choledochorrhaphy was performed following Kehr tube placements in 47 cases and transpapillary biliary stenting was conducted in the remaining 28 patients. Results: postoperative hospital stay was shorter in the stent group (5 ± 10.26 days than in the Kehr group (12 ± 10.6 days, with a statistically significant difference. There was a greater trend to grade B complications in the stent group (10.7 vs. 4.3 % and to grade C complications in the Kehr group (6.4 vs. 3.6 %. There were 3 cases of residual common bile duct stones in the Kehr group (6.4 % and none in the stent group. Conclusions: antegrade biliary stenting following laparoscopic common bile duct exploration for CL-CBDS is an effective and safe technique that prevents T-tube related morbidity.

  18. Enterprise stenting for intracranial aneurysm treatment induces dynamic and reversible age-dependent stenosis in cerebral arteries.

    Science.gov (United States)

    Gao, Bulang; Safain, Mina G; Malek, Adel M

    2015-04-01

    Although intracranial stenting has been associated with in-stent stenosis, the vascular response of cerebral vessels to the deployment of the Enterprise vascular reconstruction device is poorly defined. To evaluate the change in parent vessel caliber that ensues after Enterprise stent placement. Seventy-seven patients with 88 aneurysms were treated using Enterprise stent-assisted coil embolization and underwent high-resolution three-dimensional rotational angiography followed by three-dimensional edge-detection filtering to remove windowing-dependence measurement artifact. Orthogonal diameters and cross-sectional areas (CSAs) were measured proximal and distal on either side of the leading stent edge (points A, B), trailing stent edge (points D, E), and at mid-stent (point C). Enterprise stent deployment caused an instant increase in the parent artery CSA by 8.98% at D, which was followed 4-6 months later by significant in-stent stenosis (15.78% at A, 27.24% at B, 10.68% at C, 32.12% at D, and 28.28% at E) in the stented artery. This time-dependent phenomenon showed resolution which was complete by 12-24 months after treatment. This target vessel stenosis showed significant age dependence with greater response in the young. No flow-limiting stenosis requiring treatment was observed in this series. Use of the Enterprise stent is associated with a significant dynamic and spontaneously resolvable age-dependent in-stent stenosis. Further study is warranted on the clinical impact, if any, of this occurrence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Staged treatment of a blood blister-like aneurysm with stent-assisted coiling followed by flow diverter in-stent insertion. A case report.

    Science.gov (United States)

    Princiotta, C; Dall'olio, M; Cirillo, L; Leonardi, M

    2011-09-01

    Blood blister-like aneurysms (BBLA) are rare lesions sometimes difficult to recognize and in most cases associated with diffuse subarachnoid haemorrhage and severe clinical conditions. BBLA are life-threatening because they tend to enlarge rapidly and to rebleed, and no consensus has so far been reached on the best management strategy. We describe a patient with a BBLA in the right ICA treated successful by a two-stage embolization procedure first with coils and an open cell stent (Neuroform 3) and later by further coil placement and insertion of a flow-diverting stent (Silk).

  20. Cost-Effectiveness Analysis of Infrapopliteal Drug-Eluting Stents

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Karnabatidis, Dimitris; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Siablis, Dimitris [Patras University Hospital, Department of Interventional Radiology, School of Medicine (Greece)

    2013-02-15

    IntroductionThere are no cost-utility data about below-the-knee placement of drug-eluting stents. The authors determined the cost-effectiveness of infrapopliteal drug-eluting stents for critical limb ischemia (CLI) treatment. The event-free individual survival outcomes defined by the absence of any major events, including death, major amputation, and target limb repeat procedures, were reconstructed on the basis of two published infrapopliteal series. The first included spot Bail-out use of Sirolimus-eluting stents versus bare metal stents after suboptimal balloon angioplasty (Bail-out SES).The second was full-lesion Primary Everolimus-eluting stenting versus plain balloon angioplasty and bail-out bare metal stenting as necessary (primary EES). The number-needed-to-treat (NNT) to avoid one major event and incremental cost-effectiveness ratios (ICERs) were calculated for a 3-year postprocedural period for both strategies. Overall event-free survival was significantly improved in both strategies (hazard ratio (HR) [confidence interval (CI)]: 0.68 [0.41-1.12] in Bail-out SES and HR [CI]: 0.53 [0.29-0.99] in Primary EES). Event-free survival gain per patient was 0.89 (range, 0.11-3.0) years in Bail-out SES with an NNT of 4.6 (CI: 2.5-25.6) and a corresponding ICER of 6,518 Euro-Sign (range 1,685-10,112 Euro-Sign ). Survival gain was 0.91 (range 0.25-3.0) years in Primary EES with an NNT of 2.7 (CI: 1.7-5.8) and an ICER of 11,581 Euro-Sign (range, 4,945-21,428 Euro-Sign ) per event-free life-year gained. Two-way sensitivity analysis showed that stented lesion length >10 cm and/or DES list price >1000 Euro-Sign were associated with the least economically favorable scenario in both strategies. Both strategies of bail-out SES and primary EES placement in the infrapopliteal arteries for CLI treatment exhibit single-digit NNT and relatively low corresponding ICERs.

  1. Combined percutaneous and transurethral lithotripsy for forgotten ureteral stents with giant encrustation.

    Science.gov (United States)

    Rabani, Seyed Mohammadreza

    2012-01-01

    Ureteral stents are widely used in many urologic practices. However, stents can cause significant complications including migration, fragmentation, and encrustation and it may possibly be forgotten. Successful management of a retained, encrusted stent requires combined endourological approaches. To present our experience with the approaches for treating forgotten ureteral stents associated with giant stone formation. Seventy four patients with forgotten ureteral stents were managed by different open (nephrolithotomy and/or cystolithotomy), or endoscopic procedures in our center. Among these, 11 patients had severe encrustation (stones larger than 35 mm within the bladder or kidney) and seven patients of this group, presented at our department between July 2007 and December 2010. Combined endourological procedures percutaneous nephrolithotripsy (PCNL), cystolithotripsy (CLT), transurethral lithotripsy (TUL) were performed in one or 2 separate sessions. In these 7 patients the whole of the stents, especially both ends were encrusted. Initially, cystolithotripsy, retrograde ureteroscopy and TUL were performed in the dorsal lithotomy position. Following this, a gentle attempt was made to retrieve the stent with the help of an ureteroscopic grasper. In some cases the stent was grasped by a hemostat clamp out of the urethral meatus with a gentle traction to facilitate lithotripsy in the ureter and even in the kidney. Finally, a ureteric catheter was placed adjacent to the stent for injection of radio-contrast material to delineate the renal pelvis and the calyces. Then in the same session or later in another session the patient was placed in the prone position and PCNL of the upper coil of the encrusted stent along with calculus was done and the stent was removed. In 5 out of seven patients, the initial indication for stent placement was for urinary stone disease after open nephrolithotomy and pyeloplasty in other centers and in two patients after TUL. All patients

  2. Ureteroscopic removal of forgotten ureteral stent

    Science.gov (United States)

    Kawahara, Takashi; Ishida, Hiroaki; Kubota, Yoshinobu; Matsuzaki, Junichi

    2012-01-01

    A 69-year-old female had a right ureteral stent placed due to ureteral stricture resulting from cervical cancer in March 2008. The ureteral stent migrated to the ureter and was not exchanged. A new ureteral stent was inserted, and was exchanged every 3 months. The patient was referred to our department to remove the forgotten ureteral stent. In January 2012, her old ureteral stent was removed ureteroscopically, and no ureteral stent encrustation was found. PMID:22707678

  3. Contrast-free endoscopic stent insertion in malignant biliary obstruction

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    AIM: To present a case series of MRCP-guided endoscopic biliary stent placement, performed entirely without contrast injection.METHODS: Contrast-free endoscopic biliary drainage was attempted in 20 patients with malignant obstruction,unsuitable for resection on the basis of tumor extent or medical illness. MRCP images were used to confirm the diagnosis of tumor, to exclude other biliary diseases and to demonstrate the stenoses as well as dilation of proximal liver segments. The procedure was carried out under conscious sedation. Patients were placed in the left lateral decubitus position. The endoscope was inserted, the papilla identified and cannulated by a papillotome. A guide wire was inserted and guided deeply into the biliary tree, above the stenosis, by fluoroscopy. A papillotomy approximately 1 cm. long was performed and the papillotome was exchanged with a guiding-catheter. A 10 Fr, Amsterdam-type plastic stent,7 to 15 cm long, was finally inserted over the guide wire/guiding catheter by a pusher tube system.RESULTS: Successful stent insertion was achieved in all patients. There were no major complications. Successful drainage, with substantial reduction in bilirubin levels,was achieved in all patients.CONCLUSION: This new method of contrast-free endoscopic stenting in malignant biliary obstruction is a safe and effective method of palliation. However, a larger, randomized study comparing this new approach with the standard procedure is needed to confirm the findings of the present study.

  4. Silane surface modification for improved bioadhesion of esophageal stents

    Science.gov (United States)

    Karakoy, Mert; Gultepe, Evin; Pandey, Shivendra; Khashab, Mouen A.; Gracias, David H.

    2014-08-01

    Stent migration occurs in 10-40% of patients who undergo placement of esophageal stents, with higher migration rates seen in those treated for benign esophageal disorders. This remains a major drawback of esophageal stent therapy. In this paper, we propose a new surface modification method to increase the adhesion between self-expandable metallic stents (SEMS) and tissue while preserving their removability. Taking advantage of the well-known affinity between epoxide and amine terminated silane coupling agents with amine and carboxyl groups that are abundant in proteins and related molecules in the human body; we modified the surfaces of silicone coated esophageal SEMS with these adhesive self-assembled monolayers (SAMs). We utilized vapor phase silanization to modify the surfaces of different substrates including PDMS strips and SEMS, and measured the force required to slide these substrates on a tissue piece. Our results suggest that surface modification of esophageal SEMS via covalent attachment of protein-binding coupling agents improves adhesion to tissue and could offer a solution to reduce SEMS migration while preserving their removability.

  5. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Orgera, Gianluigi; Bezzi, Mario; Rossi, Plinio; Allegritti, Massimiliano; Passariello, Roberto [University of Rome, Department of Radiological Sciences, Rome (Italy)

    2008-05-15

    To evaluate the efficacy and safety of an expanded polytetrafluoroethylene-fluorinated ethylene-propylene (ePTFE/FEP)-covered metallic stent in the management of malignant biliary obstruction. Eighty consecutive patients with malignant common bile duct strictures were treated by placement of 83 covered metallic stents. The stent-graft consists of an inner ePTFE/FEP lining and an outer supporting structure of nitinol wire. Clinical evaluation, assessment of serum bilirubin and liver enzyme levels were analyzed before biliary drainage, before stent-graft placement and during the follow-up period at 1, 3, 6, 9 and 12 months. Technical success was obtained in all cases. After a mean follow-up of 6.9{+-}4.63 months, the 30-day mortality rate was 14.2%. Survival rates were 40% and 20.2% at 6 and 12 months, respectively. Stent-graft patency rates were 95.5%, 92.6% and 85.7% at 3, 6 and 12 months, respectively. Complications occurred in five patients (6.4%); among these, acute cholecystitis was observed in three patients (3.8%). A stent-graft occlusion rate of 9% was observed. The percentage of patients undergoing lifetime palliation (91%) and the midterm patency rate suggest that placement of this ePTFE/FEP-covered stent-graft is safe and highly effective in achieving biliary drainage in patients with malignant strictures of the common bile duct. (orig.)

  7. Transanal drainage tube reduces rate and severity of anastomotic leakage in patients with colorectal anastomosis: A case controlled study

    Directory of Open Access Journals (Sweden)

    A. Brandl

    2016-03-01

    Conclusions: Placement of a transanal drainage tube in patients with colorectal anastomoses is a safe and simple technique to perform and reduces anastomotic leakage, the severity of the complication and hospital stay.

  8. Endoscopic suture fixation is associated with reduced migration of esophageal fully covered self-expandable metal stents (FCSEMS).

    Science.gov (United States)

    Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan

    2016-12-07

    Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.

  9. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  10. Theoretical prediction of side branch compromise after main branch stenting in coronary bifurcation

    Institute of Scientific and Technical Information of China (English)

    Dobrin Vassilev; Robert Gil

    2008-01-01

    One of the main problems of treatment of bifurcation lesions is side branch (SB) stenosis appearing after stent placement in the main vessel.The aim of this study was to create quantitative method for prediction of side branch compromise extent.We accepted that the main mechanism for SB ostial stenosis is flow divider (FD) displacement from stent struts after stent implantation in the main vessel.Using easily measurable parameters from coronary angiography,as SB diameter,angle α (initial angle between axes of parent vessel and SB axis) and angle α' (angle between above mentioned axes after stent placement) we can calculate percentage diameter stenosis at branch ostium (%DS):%DS = sin (α - α')/(tan α).In boundary condition of full FD displacement %DS = cos α.We tested our theoretical predictions with fluoroscopic observation of elastic wall model of bifurcation (45°distal angle between branches)permitting wall deformations with stent.There is full coincidence of values of %DS and percentage area stenosis (%AS).The regular formulas for calculations of %DS and %AS overestimate stenosis severity between 10% and 25%.Our model tests have shown full coincidence between predicted values for %DS and observed values.We demonstrate that part of the SB ostium is not visible in regular angiography and contributes to ostial lumen area.This is a method that permits quantitative prediction of side branch compromise.

  11. Endovascular stenting in superior vena cava syndrome: utility of a through-and-through guidewire technique

    Energy Technology Data Exchange (ETDEWEB)

    Clark, T.W.I. [Dalhousie Univ., Queen Elizabeth II Health Sciences Centre, Section of Interventional Radiology, Dept. of Diagnostic Imaging, Halifax, NS (Canada)

    2000-08-01

    Objective: To describe an ancillary technique when a conventional femoral approach to superior vena cava (SVC) stent placement is not feasible because of buckling of balloon catheters or stent-deployment systems during device advancement. Patients and methods: Three patients in whom device advancement across the SVC lesion from a femoral or axillary approach was unsuccessful were managed by accessing the right jugular vein; SVC lesions were crossed from an antegrade direction, and the jugular guidewire was secured at the femoral access site to create a through-and-through guidewire. Results: Countertraction on the through-and-through guidewire during stent placement and dilation permitted unhindered advancement of stent delivery systems and catheters across the SVC. Technical and clinical success was achieved in each patient with relief of SVC syndrome within 24-72 hours. Survival ranged from 26 to 137 days. Conclusion: A through-and-through guidewire technique is useful when stenting a highly stenotic or thrombosed SVC in patients with superior vena cava syndrome. (author)

  12. A Multicenter, Prospective Study of a New Fully Covered Expandable Metal Biliary Stent for the Palliative Treatment of Malignant Bile Duct Obstruction

    Directory of Open Access Journals (Sweden)

    Bret T. Petersen

    2013-01-01

    Full Text Available Background and Study Aims. Endoscopic placement of self-expanding metal stents (SEMSs is indicated for palliation of inoperable malignant biliary obstruction. A fully covered biliary SEMS (WallFlex Biliary RX Boston Scientific, Natick, USA was assessed for palliation of extrahepatic malignant biliary obstruction. Patients and Methods. 58 patients were included in this prospective, multicenter series conducted under an FDA-approved IDE. Main outcome measurements included (1 absence of stent occlusion within six months or until death, whichever occurred first and (2 technical success, need for reintervention, bilirubin levels, stent patency, time to stent occlusion, and adverse events. Results. Technical success was achieved in 98% (57/58, with demonstrated acute removability in two patients. Adequate clinical palliation until completion of followup was achievedin 98% (54/55 of evaluable patients, with 1 reintervention due to stent obstruction after 142 days. Mean total bilirubin decreased from 8.9 mg/dL to 1.2 mg/dL at 1 month. Device-related adverse events were limited and included 2 cases of cholecystitis. One stent migrated following radiation therapy. Conclusions. The WallFlex Biliary fully covered stent yielded technically successful placement with uncomplicated acute removal where required, appropriate reduction in bilirubin levels, and low rates of stent migration and occlusion. This SEMS allows successful palliation of malignant extrahepatic biliary obstruction.

  13. Stent-assisted coil embolization of intracranial wide-necked aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Jun [Bundang CHA Hospital, Department of Diagnostic Radiology, Pochon CHA University College of Medicine, Gyeonggi-do (Korea); Kim, Dong Joon; Suh, Sang Hyun; Lee, Seung-Koo; Kim, Jinna; Kim, Dong Ik [Yonsei University College of Medicine, Severance Hospital, Department of Diagnostic Radiology and Research Institute of Radiological Science, Seoul (Korea)

    2005-09-01

    The endovascular treatment of cerebral aneurysms with coils poses significant technical challenges, particularly with respect to wide-necked aneurysms. We present the results of our initial experiences in using a stent for endovascular treatment of aneurysms, with an emphasis on potential applications, technical aspects, and associated complications. Twenty-three wide-necked aneurysms from 22 patients were treated during the 13-month study period. Seven patients presented with subarachnoid hemorrhage. Aneurysms were located at the internal carotid artery (n=14), the vertebral artery (n=3), the basilar artery (n=5), and the middle cerebral artery (n=1). A Neuroform stent{sup 2} was used for stent-assisted procedures. Premedication with antithrombotic agents was available for unruptured cases. Postprocedural antithrombotic medication was prescribed for all patients. Nineteen aneurysms were primarily stented, followed by coil placement. For five of these aneurysms, stenting was performed subsequent to failure of an attempt to frame with an initial coil. Stenting for the remaining four aneurysms was performed as a rescue procedure to prevent the migration of previously placed coils. Complete occlusion was obtained in ten aneurysms, nearly complete occlusion (95% or more occluded) in 11 aneurysms, and partial occlusion (less than 95% occluded) in one aneurysm. In one aneurysm, we failed to navigate the microcatheter into the aneurysmal sac through the interstices of the stent. Stent thrombosis was noted during the procedure in one patient. Hemorrhagic complication on the 25th day after the procedure was noted in one patient. No procedure-related complications were observed during the procedure or during follow-up in the remaining 20 patients, including seven patients who did not receive antithrombotic agents prior to endovascular treatment owing to recent subarachnoid hemorrhage. To overcome the technical limitation in the coiling of wide-necked aneurysms, stent

  14. Nasal packing and stenting

    Directory of Open Access Journals (Sweden)

    Weber, Rainer K.

    2009-01-01

    Full Text Available Nasal packs are indispensable in ENT practice. This study reviews current indications, effectiveness and risks of nasal packs and stents. In endoscopic surgery, nasal packs should always have smooth surfaces to minimize mucosal damage, improve wound healing and increase patient comfort. Functional endoscopic endonasal sinus surgery allows the use of modern nasal packs, since pressure is no longer required. So called hemostatic/resorbable materials are a first step in this direction. However, they may lead to adhesions and foreign body reactions in mucosal membranes. Simple occlusion is an effective method for creating a moist milieu for improved wound healing and avoiding dryness. Stenting of the frontal sinus is recommended if surgery fails to produce a wide, physiologically shaped drainage path that is sufficiently covered by intact tissue.

  15. Clinical outcomes of self-expandable stent placementfor benign esophageal diseases: A pooled analysis of theliterature

    Institute of Scientific and Technical Information of China (English)

    Emo E van Halsema; Jeanin E van Hooft

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stentplacement for benign esophageal strictures and benignesophageal leaks in the literature.METHODS: The PubMed, Embase and Cochranedatabases were searched for relevant articles publishedbetween January 2000 and July 2014. Eight prospectivestudies were identified that analyzed the outcomesof stent placement for refractory benign esophagealstrictures. The outcomes of stent placement forbenign esophageal leaks, perforations and fistulaewere extracted from 20 retrospective studies thatwere published after the inclusion period of a recentsystematic review. Data were pooled and analyzedusing descriptive statistics.RESULTS: Fully covered self-expandable metal stents(FC SEMS) (n = 85), biodegradable (BD) stents (n =77) and self-expandable plastic stents (SEPS) (n = 70)were inserted in 232 patients with refractory benignesophageal strictures. The overall clinical success ratewas 24.2% and according to stent type 14.1% forFC SEMS, 32.9% for BD stents and 27.1% for SEPS.Stent migration occurred in 24.6% of cases. Theoverall complication rate was 31.0%, including major(17.7%) and minor (13.4%) complications. A total of643 patients were treated with self-expandable stentsmainly for postsurgical leaks (64.5%), iatrogenicperforations (19.6%), Boerhaave's syndrome (7.8%)and fistulae (3.7%). FC SEMS and partially coveredSEMS were used in the majority of patients. Successfulclosure of the defect was achieved in 76.8% ofpatients and according to etiology in 81.4% forpostsurgical leaks, 86.0% for perforations and 64.7%for fistulae. The pooled stent migration rate was16.5%. Stent-related complications occurred in 13.4%of patients, including major (7.8%) and minor (5.5%)complications.CONCLUSION: The outcomes of stent placementfor refractory benign esophageal strictures were poor.However, randomized trials are needed to put thisinto perspective. The evidence on successful

  16. Forgotten Reminders: an Experience with Managing 28 Forgotten Double-J Stents and Management of Related Complications.

    Science.gov (United States)

    Sohrab, Arora; Aneesh, Srivastava; Sureka, Sanjoy Kumar; Varun, Mittal; Nitesh, Patidar; Manoj, Kumar; Rakesh, Kapoor

    2015-12-01

    Combinations of extracorporeal shockwave lithotripsy (ESWL) and endourological and open surgery have been used for management of forgotten double-J (DJ) stents; however, there are only a few case reports or case series in literature. We present our experience of managing 28 cases of forgotten ureteric stents of whom three patients died because of complications after intervention. We retrospectively reviewed the hospital records of 28 cases of forgotten DJ stents from 2000 to 2013. The details reviewed included indications for stent placement, indwelling time, presenting complaints, laboratory, radiographic, nuclear scan findings, management techniques, and complications. Extensive review of literature was done. Mean patient age was 37.7 ± 14 years. Mean indwelling time was 102.9 months. The commonest presenting complaints were irritative voiding symptoms and hematuria. Nineteen (67.8 %) of the stents were complicated. The complicated stents were managed by a combination of endourological techniques and ESWL. Six (21.5 %) patients presented with renal failure. Three patients died of complications. Forgotten DJ stent can be a lethal yet entirely preventable complication. Preoperative imaging with a noncontrast CT is essential especially in long indwelling time, especially to evaluate stone burden at the upper end of the stent. A stepwise approach should be used for management. Where long operative times are expected, the procedure must be staged. Combined endourological procedures are almost always successful in managing these challenging cases.

  17. Prevention of potential complications related to transjugular intrahepatic portosystemic shunt procedure: efficacy of polytetrafluoroethylene stent grfat

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Jae Hong; Seong, Chang Kyu [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of); Kim, Young Hwan; Choi, Jin Soo; Lee, Sang Kwon; Kim, Gab Chul [School of Medicine, Keimyung Univ., Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of); Seong, Nak Kwan; Park, Young Chan [School of Medicine, Daegu Catholic Univ., Daegu (Korea, Republic of)

    2004-11-01

    The purpose of this study was to assess the efficacy of a polytetrafluoroethylene (PTFE) stent graft for preventing potential complications related to a transjugular intrahepatic portosystemic shunt (TIPS). Between January 2002 and March 2003, seven patients (males: 5, females: 2, mean age: 44) underwent TIPS stent placement using the PTFE stent graft (Nitis,Taewoong, Seoul, Korea) to prevent potential complications such as life threatening hemoperitoneum, hemobilia and early stent occlusion. Three patients were admitted for esophageal varix bleeding, three patients were admitted for gastric varix bleeding and one patient was admitted for umbilical bleeding. The extrahepatic portal vein was punctured inadvertently in four patients (main portal vein: 1 case, portal vein bifurcation: 3 cases), but contrast media extravasation into the peritoneal cavity on the tractogram was noted only in two patients. Two of four patients had chronic portal vein occlusion with intra- and extrahepatic cavernous transformation. The bile duct was inadvertently punctured and visualized on the tractogram in three patients. All the identified biliary trees or contrast media extravasations observed on the tractograms were successfully sealed off on the post-procedure portograms. The immediate post-procedure clinical recovery courses were uneventful in all patients (no hemobilia or hemoperitoneum was noted). Bleeding control was successful in all patients. The one patient who had Child-Pugh cIass C disease died of hepatic encephalopathy 3 days after TIPS placement. Five of the six living patients have not shown any complications or rebleeding during the follow up periods (9-23 months). The one patient who had biliary communication on the tractogram rebled due to TIPS stent stenosis 25 days after TIPS, and this patient was successfully treated by TIPS revision. Potential complications related to TIPS procedure can be successfully prevented with PTFE stent graft placement.

  18. Carotid artery stenting: which stent for which lesion?

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen; Verbist, Jürgen; Peeters, Patrick

    2005-01-01

    The different geometries and working principles of carotid stents (nitinol or cobalt chromium, open- or closed-cell configuration) provide each product with unique functional properties. The individual characteristics of each device may make it an attractive choice in one circumstance but render it less desirable in other situations. In approximately 75% of all procedures, all types of stents will achieve similar outcomes, making adequate device selection unnecessary. For the remaining quarter, careful preoperative screening is mandatory. In addition to eventual access issues, the choice of the optimal carotid stent depends mainly on arterial anatomy and lesion morphology. When treating a tortuous anatomy, stents with a flexible and comformable open-cell configuration are preferred. In arteries with a significant mismatch between common carotid artery and internal carotid artery diameter, cobalt chromium (Elgiloy) or tapered nitinol stents are selected. Lesions with suspected high emboligenicity are best covered with stents with a closed-cell configuration, whereas highly calcified lesions need treatment with nitinol stents. Thorough knowledge of the characteristics, advantages and disadvantages, and working principles of the different available stents is mandatory to optimally select the materials to be used for patients eligible for carotid revascularization.

  19. Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations.

    Science.gov (United States)

    Beier, Susann; Ormiston, John; Webster, Mark; Cater, John; Norris, Stuart; Medrano-Gracia, Pau; Young, Alistair; Cowan, Brett

    2016-02-01

    Stent induced hemodynamic changes in the coronary arteries are associated with higher risk of adverse clinical outcome. The purpose of this study was to evaluate the impact of stent design on wall shear stress (WSS), time average WSS, and WSS gradient (WSSG), in idealized stent geometries using computational fluid dynamics. Strut spacing, thickness, luminal protrusion, and malapposition were systematically investigated and a comparison made between two commercially available stents (Omega and Biomatrix). Narrower strut spacing led to larger areas of adverse low WSS and high WSSG but these effects were mitigated when strut size was reduced, particularly for WSSG. Local hemodynamics worsened with luminal protrusion of the stent and with stent malapposition, adverse high WSS and WSSG were identified around peak flow and throughout the cardiac cycle respectively. For the Biomatrix stent, the adverse effect of thicker struts was mitigated by greater strut spacing, radial cell offset and flow-aligned struts. In conclusion, adverse hemodynamic effects of specific design features (such as strut size and narrow spacing) can be mitigated when combined with other hemodynamically beneficial design features but increased luminal protrusion can worsen the stent's hemodynamic profile significantly.

  20. Mid-Term Follow-Up of Drug-Eluting Stenting for In-Stent Restenosis: Bare-Metal Stents versus Drug- Eluting Stents

    Directory of Open Access Journals (Sweden)

    Negar Faramarzi

    2015-10-01

    Full Text Available Background: Despite major advances in percutaneous coronary intervention (PCI, in-stent restenosis (ISR remains a therapeutic challenge. We sought to compare the mid-term clinical outcomes after treatment with repeat drug-eluting stent (DES implantation (“DES sandwich” technique with DES placement in the bare-metal stent (DES-in-BMS in a "real world" setting.Methods: We retrospectively identified and analyzed clinical and angiographic data on 194 patients previously treated with the DES who underwent repeat PCI for ISR with a DES or a BMS. ISR was defined, by visual assessment, as a luminal stenosis greater than 50% within the stent or within 5 mm of its edges. We recorded the occurrence of major adverse cardiac events (MACE, defined as cardiac death, non-fatal myocardial infarction, and the need for target vessel revascularization (TVR.Results: Of the 194 study participants, 130 were men (67.0% and the mean ± SD of age was 57.0 ± 10.4 years, ranging from37 to 80 years. In-hospital events (death and Q-wave myocardial infarction occurred at a similar frequency in both groups. Outcomes at twelve months were also similar between the groups with cumulative clinical MACE at one-year follow-up of 9.6% and 11.3% in the DES-in-BMS and the DES-in-DES groups, respectively (p value = 0.702. Although not significant, there was a trend toward a higher TVR rate in the intra-DES ISR group as compared to the intra-BMS ISR group (0.9% BMS vs. 5.2% DES; p value = 0.16.Conclusion: Our study suggests that the outcome of the patients presenting with ISR did not seem to be different between the two groups of DES-in-DES and DES-in-BMS at one-year follow-up, except for a trend toward more frequent TVR in the DES-in-DES group. Repeat DES implantation for DES restenosis could be feasible and safe with a relatively low incidence of MACE at mid-term follow-up.

  1. Colorectal cancer screening.

    Science.gov (United States)

    Burt, Randall W; Cannon, Jamie A; David, Donald S; Early, Dayna S; Ford, James M; Giardiello, Francis M; Halverson, Amy L; Hamilton, Stanley R; Hampel, Heather; Ismail, Mohammad K; Jasperson, Kory; Klapman, Jason B; Lazenby, Audrey J; Lynch, Patrick M; Mayer, Robert J; Ness, Reid M; Provenzale, Dawn; Rao, M Sambasiva; Shike, Moshe; Steinbach, Gideon; Terdiman, Jonathan P; Weinberg, David; Dwyer, Mary; Freedman-Cass, Deborah

    2013-12-01

    Mortality from colorectal cancer can be reduced by early diagnosis and by cancer prevention through polypectomy. These NCCN Guidelines for Colorectal Cancer Screening describe various colorectal screening modalities and recommended screening schedules for patients at average or increased risk of developing colorectal cancer. In addition, the guidelines provide recommendations for the management of patients with high-risk colorectal cancer syndromes, including Lynch syndrome. Screening approaches for Lynch syndrome are also described.

  2. Nearshore Placement Webinar: Nearshore Placement Research & Development

    Science.gov (United States)

    2012-11-29

    Huntington Beach (SANDAG) Shark River Inlet (NAN) Assateague Island, MD (NAB) Positive Recreational Feature Small Dispersive Placements Innovative...Coordination Act  Endangered Species Act  Coastal Zone Management Act – Sec. 307(c)  Marine Protection, Research, and Sanctuaries Act

  3. Effect of technical parameters on transjugular intrahepatic portosystemic shunts utilizing stent grafts.

    Science.gov (United States)

    Andring, Brice; Kalva, Sanjeeva P; Sutphin, Patrick; Srinivasa, Rajiv; Anene, Alvin; Burrell, Marc; Xi, Yin; Pillai, Anil K

    2015-07-14

    To assess the effect of technical parameters on outcomes of transjugular intrahepatic portosystemic shunt (TIPS) created using a stent graft. The medical records of 68 patients who underwent TIPS placement with a stent graft from 2008 to 2014 were reviewed by two radiologists blinded to the patient outcomes. Digital Subtraction Angiographic images with a measuring catheter in two orthogonal planes was used to determine the TIPS stent-to-inferior vena cava distance (SIVCD), hepatic vein to parenchymal tract angle (HVTA), portal vein to parenchymal tract angle (PVTA), and the accessed portal vein. The length and diameter of the TIPS stent and the use of concurrent variceal embolization were recorded by review of the patient's procedure note. Data on re-intervention within 30 d of TIPS placement, recurrence of symptoms, and survival were collected through the patient's chart. Cox proportional regression analysis was performed to assess the effect of these technical parameters on primary patency of TIPS, time to recurrence of symptoms, and all-cause mortality. There was no significant association between the SIVCD and primary patency (P = 0.23), time to recurrence of symptoms (P = 0.83), or all-cause mortality (P = 0.18). The 3, 6, and 12-mo primary patency rates for a SIVCD ≥ 1.5 cm were 82.4%, 64.7%, and 50.3% compared to 89.3%, 83.8%, and 60.6% for a SIVCD of technical parameters and time to recurrence of symptoms or all-cause mortality. Recurrence of symptoms was associated with stent graft stenosis (P = 0.03). TIPS stent-to-caval distance and other parameters have no significant effect on primary patency, time to recurrence of symptoms, or all-cause mortality following TIPS with a stent-graft.

  4. Treatment of gastric outlet and duodenal obstructions with uncovered expandable metal stents

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    AIM: To investigate and evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided peroral uncovered expandable metal stent placement to treat gastric outlet and duodenal obstructions. METHODS: Fifteen consecutive patients underwent peroral placement of WallstentTM Enteral Endoprosthesis to treat gastric outlet and duodenal obstructions (14 malignant, 1 benign). All procedures were completed under fluoroscopic guidance without endoscopic assistance. Follow-up was completed until the patients died or were lost, and the clinical outcomes were analyzed. RESULTS: The technique success rate was 100%, and the oral intake was maintained in 12 of 14 patients varying from 7 d to 270 d. Two patients remained unable to resume oral intake, although their stents were proven to be patent with the barium study. One patient with acute necrotizing pancreatitis underwent enteral stenting to treat intestinal obstruction, and nausea and vomiting disappeared. Ten patients died during the followup period, and their mean oral intake time was 50 d. No procedure-related complications occurred. Stent migration to the gastric antrum occurred in one patient 1 year after the procedure, a tumor grew at the proximal end of the stent in another patient 38 d post-stent insertion. CONCLUSION: Fluoroscopically guided peroral metal stent implantation is a safe and effective method to treat malignant gastrointestinal obstructions, and complications can be ignored based on our short-term study. Indications for this procedure should be discreetly considered because a few patients may not benefit from gastrointestinal insertion, but some benign gastrointestinal obstructions can be treated using this procedure.

  5. Intravascular ultrasound-guided stenting of left main stem dissection after Medtronic Corevalve implantation.

    Science.gov (United States)

    Van Mieghem, N M; de Jaegere, P P

    2013-08-01

    Transcatheter aortic valve implantation (TAVI) implies the introduction, positioning, and deployment of a stented bioprosthesis in the (calcified) native aortic valve. We report an at first glance uneventful TAVI with the Medtronic Corevalve System, which was followed by transient electrocardiographic changes suggesting acute left main stem disease. The diagnosis of acute left main stem dissection extending from the left coronary cusp was firmly established by intravascular ultrasound. The ostium of the left main stem was successfully treated with intravascular ultrasound-guided placement of a drug eluting stent. © 2013 Wiley Periodicals, Inc.

  6. Stent-assisted intracranial angioplasty: potentials and limitations of pre- and postinterventional CT angiography; Stentgestuetzte intrakranielle Angioplastie: Moeglichkeiten und Grenzen der prae- und postinterventionellen CT-Angiografie

    Energy Technology Data Exchange (ETDEWEB)

    Schloetzer, W.; Schmitz, B.L. [Universitaetsklinikum Ulm (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Huber, R. [Universitaetsklinikum Ulm (Germany). Klinik fuer Neurologie

    2009-02-15

    CT angiography (CTA) is a noninvasive technique for evaluating intracranial arterial stenoses and for following up on intracranial stents. We analyzed a series of patients to assess the capabilities of CTA with respect to preinterventional und postinterventional diagnostic imaging for stent-assisted intracranial angioplasty. We examined 8 patients with 9 symptomatic intracranial arterial stenoses before and after stent placement with CTA. CT angiographies were compared to the periprocedural conventional angiography with regard to the quality of the visualization as well as the dimensions of the identified stenoses and the implanted stents. The extent of the preinterventional intracranial stenoses identified with CTA differed between -15 % to + 12 % from conventional angiography. In any case we were able to assess stent position, expansion, and perfusion with postinterventional CTA. The mean residual stenosis after stent placement was 33 % (13 - 48 %) measured with conventional angiography and it was accurately estimated with a difference of {+-} 15 % in 5 of 9 stents by CTA. 4 residual stenoses were underestimated or overestimated between -20 % and + 26 %. Further CTA controls of several patients showed good visualization of in-stent neointimal hyperplasia. CTA is useful for stent planning and follow-up of symptomatic intracranial stenoses. Intracranial stents and their lumina are adequately visualized by CTA, especially in vertebrobasilar vessels. However, residual stenosis and restenosis especially in the intracranial internal carotid artery and in the presence of calcified plaques may be incorrectly estimated by CTA. In case of doubt patients must undergo invasive angiography. In summary the use of CTA is a possibility for the primary follow-up of intracranial stents. It cannot generally prevent further diagnostics, but it is a potential method for reducing invasive angiography. (orig.)

  7. Heparin-Coated Coronary Stents.

    Science.gov (United States)

    van Der Giessen WJ; van Beusekom HM; Larsson; Serruys

    1999-09-01

    The development of the heparin-coated (HC)-stent should be viewed against the backdrop of the early unfavorable results with noncoated stents in the pre-intravascular ultrasound and pre-ticlopidine era. Notwithstanding, results of pilot and randomized trials show a surprisingly low incidence of (sub)acute stent thrombosis under challenging circumstances, such as acute coronary syndromes. Considering the quite low incidence of early complications with noncoated second-generation stents, it may require large trials to prove the clinical efficacy of the heparin- coating against noncoated devices. However, even if the "added value" of the heparin-coating will never be clinically proven, it has helped to enhance the penetration of stent therapy in interventional cardiology. Unlike the situation in 1992, very few cardiologists will now disagree with the statement that stents contribute to the state-of-the-art treatment of patients with angina pectoris or acute myocardial infarction. A preliminary comparison of available trials also suggests that the heparin-coated Palmaz-Schatz stent (Cordis Corp., Waterloo, Belgium) is as effective as the noncoated stent plus abciximab treatment.

  8. A new removable airway stent

    Directory of Open Access Journals (Sweden)

    Tore Amundsen

    2016-09-01

    Full Text Available Background: Malignant airway obstruction is a feared complication and will most probably occur more frequently in the future because of increasing cancer incidence and increased life expectancy in cancer patients. Minimal invasive treatment using airway stents represents a meaningful and life-saving palliation. We present a new removable airway stent for improved individualised treatment. Methods: To our knowledge, the new airway stent is the world's first knitted and uncovered self-expanding metal stent, which can unravel and be completely removed. In an in vivo model using two anaesthetised and spontaneously breathing pigs, we deployed and subsequently removed the stents by unravelling the device. The procedures were executed by flexible bronchoscopy in an acute and a chronic setting – a ‘proof-of-principle’ study. Results: The new stent was easily and accurately deployed in the central airways, and it remained fixed in its original position. It was easy to unravel and completely remove from the airways without clinically significant complications. During the presence of the stent in the chronic study, granulation tissue was induced. This tissue disappeared spontaneously with the removal. Conclusions: The new removable stent functioned according to its purpose and unravelled easily, and it was completely removed without significant technical or medical complications. Induced granulation tissue disappeared spontaneously. Further studies on animals and humans are needed to define its optimal indications and future use.

  9. Stents for malignant ureteral obstruction

    Directory of Open Access Journals (Sweden)

    Kristina Pavlovic

    2016-07-01

    Full Text Available Malignant ureteral obstruction can result in renal dysfunction or urosepsis and can limit the physician's ability to treat the underlying cancer. There are multiple methods to deal with ureteral obstruction including regular polymeric double J stents (DJS, tandem DJS, nephrostomy tubes, and then more specialized products such as solid metal stents (e.g., Resonance Stent, Cook Medical and polyurethane stents reinforced with nickel-titanium (e.g., UVENTA stents, TaeWoong Medical. In patients who require long-term stenting, a nephrostomy tube could be transformed subcutaneously into an extra-anatomic stent that is then inserted into the bladder subcutaneously. We outline the most recent developments published since 2012 and report on identifiable risk factors that predict for failure of urinary drainage. These failures are typically a sign of cancer progression and the natural history of the disease rather than the individual type of drainage device. Factors that were identified to predict drainage failure included low serum albumin, bilateral hydronephrosis, elevated C-reactive protein, and the presence of pleural effusion. Head-to-head studies show that metal stents are superior to polymeric DJS in terms of maintaining patency. Discussions with the patient should take into consideration the frequency that exchanges will be needed, the need for externalized hardware (with nephrostomy tubes, or severe urinary symptoms in the case of internal DJS. This review will highlight the current state of diversions in the setting of malignant ureteral obstruction.

  10. Get Tested for Colorectal Cancer

    Science.gov (United States)

    ... Print This Topic En español Get Tested for Colorectal Cancer Browse Sections The Basics Overview What to Expect ... section Overview 2 of 6 sections The Basics: Colorectal Cancer What is colorectal cancer? Colorectal cancer is a ...

  11. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis

    DEFF Research Database (Denmark)

    Jensen, Jesper Khedri; Jensen, Lisette Okkels; Terkelsen, Christian Juhl;

    2013-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  12. [Longitudinal stent deformation during bifurcation lesion treatment].

    Science.gov (United States)

    Mami, Z; Monsegu, J

    2014-12-01

    Longitudinal stent deformation is defined as a compression of stent length after its implantation. It's a rare complication but dangerous seen with several stents. We reported a case of longitudinal stent deformation during bifurcation lesion treatment with a Promus Element(®) and we perform a short review of this complication.

  13. CT virtual endoscopy and 3D stereoscopic visualisation in the evaluation of coronary stenting.

    Science.gov (United States)

    Sun, Z; Lawrence-Brown

    2009-10-01

    The aim of this case report is to present the additional value provided by CT virtual endoscopy and 3D stereoscopic visualisation when compared with 2D visualisations in the assessment of coronary stenting. A 64-year old patient was treated with left coronary stenting 8 years ago and recently followed up with multidetector row CT angiography. An in-stent restenosis of the left coronary artery was suspected based on 2D axial and multiplanar reformatted images. 3D virtual endoscopy was generated to demonstrate the smooth intraluminal surface of coronary artery wall, and there was no evidence of restenosis or intraluminal irregularity. Virtual fly-through of the coronary artery was produced to examine the entire length of the coronary artery with the aim of demonstrating the intraluminal changes following placement of the coronary stent. In addition, stereoscopic views were generated to show the relationship between coronary artery branches and the coronary stent. In comparison with traditional 2D visualisations, virtual endoscopy was useful for assessment of the intraluminal appearance of the coronary artery wall following coronary stent implantation, while stereoscopic visualisation improved observers' understanding of the complex cardiac structures. Thus, both methods could be used as a complementary tool in cardiac imaging.

  14. A case of methicillin-resistant Staphylococcus aureus infection following bile duct stenting

    Institute of Scientific and Technical Information of China (English)

    Markus K Diener; Alexis Ulrich; Theresia Weber; Moritz N Wente; Markus W Büchler; Helmut Friess

    2005-01-01

    AIM: To present a case of methicillin-resistant Staphylococcus aureus (MRSA) infection following bile duct stenting in a patient with malignant biliary obstruction.METHODS: A 78-year-old male patient was admitted to a community hospital with progredient painless jaundice lasting over two weeks, weight loss and sweating at night.Whether a stent should be implanted pre-operatively in jaundiced patients or whether these patients should directly undergo surgical resection, was discussed.RESULTS: ERC and a biopsy from the papilla of Vater revealed an adenocarcinoma. In addition, a 7-Ch plastic stent was placed into the common bile duct. Persistent abdominal pain, increasing jaundice, weakness and indigestion led to the transfer of the patient to our hospital.A pylorus-preserving pancreatoduodenectomy wasperformed. Intraoperatively, bile leaked out of the transected choledochus andthe stent was found to be dislocated in the duodenum. A smear of the bile revealed an infection with MRSA, leading to post-operative isolation of the patient.CONCLUSION:As biliary stents can cause severe infection of the bile, the need for pre-operative placement of biliary stents should be carefully evaluated in each individual case.

  15. Ureteral Stenting after Uncomplicated Ureteroscopy for Distal Ureteral Stones: A Randomized, Controlled Trial

    Directory of Open Access Journals (Sweden)

    Y. El Harrech

    2014-01-01

    Full Text Available Objectives. We compared outcome and complications after uncomplicated ureteroscopic treatment of distal ureteral calculi with or without the use of ureteral stents. Materials and Methods. 117 patients, prospectively divided into three groups to receive a double j stent (group 1, 42 patients, ureteral stent (group 2, 37 patients, or no stent (group 3, 38 patients, underwent ureteroscopic treatment of distal ureteral calculi. Stone characteristics, operative time, postoperative pain, lower urinary tract symptoms (LUTS, analgesia need, rehospitalization, stone-free rate, and late postoperative complications were all studied. Results. There were no significant differences in preoperative data. There was no significant difference between the three groups regarding hematuria, fever, flank pain, urinary tract infection, and rehospitalisation. At 48 hours and 1 week, frequency/urgency and dysuria were significantly less in the nonstented group. When comparing group 1 and group 3, patients with double j stents had statistically significantly more bladder pain (P=0.003, frequency/urgency (P=0.002, dysuria (P=0.001, and need of analgesics (P=0.001. All patients who underwent imaging postoperatively were without evidence of obstruction or ureteral stricture. Conclusions. Uncomplicated ureteroscopy for distal ureteral calculi without intraoperative ureteral dilation can safely be performed without placement of a ureteral stent.

  16. Combined stent and coil in endovascular treatment of intracranial wide-necked and fusiform aneurysms

    Institute of Scientific and Technical Information of China (English)

    刘建民; 黄清海; 许奕; 洪波; 张珑; 张鑫

    2004-01-01

    Background Wide-necked and fusiform aneurysms are challenges for interventional neuroradiologists and neurosurgeons since they may involve entire vessels or be irregular in shape, making is possible for Guglielmi detachable coil to protrude into the parent arteries. This study was to evaluate the endovascular treatment of intracranial wide-necked and fusiform aneurysms by using a combination of stents and coils.Methods From October 2000 to July 2001, eighteen patients with intracranial wide-necked or fusiform aneurysms were treated with intraluminal stenting in combination with endosaccular coiling.Results Stent placement and coil packing were technically successful in all patients. There were no complications related to the procedure except for the migration of the stent in four cases. The aneurysms were embolized with the coils after precise stenting, and total occlusion was obtained in 13 cases, neck remnants in 3, and loose occlusion in 2. All the patients recovered well. Short-term follow-up angiograms suggested patency of the parent arteries without recanalization.Conclusions A combination of endovascular stenting and coil packing may be a favorable alternative for the treatment of intracranial aneurysms that are unsuitable for surgical clipping or coil embolization. Further study is necessary to assess the long-term outcome.

  17. A Newly Designed Stent for Management of Malignant Distal Duodenal Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Wei-Zhong, E-mail: xmjbq007@163.com; Yang, Zheng-Qiang, E-mail: ntdoctoryang@hotmail.com; Liu, Sheng, E-mail: liusheng1137@sina.com; Zhou, Chun-Gao, E-mail: zhouchungao@aliyun.com; Xia, Jin-Guo, E-mail: docjinguoxia@hotmail.com; Zhao, Lin-Bo, E-mail: linberzhao@hotmail.com; Shi, Hai-Bin, E-mail: shihb@njmu.edu.cn [The First Affiliated Hospital of Nanjing Medical University, Department of Interventional Radiology (China)

    2015-02-15

    PurposeTo evaluate the clinical effectiveness of a newly designed stent for the treatment of malignant distal duodenal stenosis.MethodsFrom March 2011 to May 2013, six patients with malignant duodenal stenosis underwent fluoroscopically guided placement of the new duodenal stent consisting of braided, nested stent wires, and a delivery system with a metallic mesh inner layer. Primary diseases were pancreatic cancer in three patients, gastric cancer in two patients, and endometrial stromal sarcoma in one patient. Duodenal obstructions were located in the horizontal part in two patients, the ascending part in two patients, and the duodenojejunal flexure in two patients. Technical success, defined as the successful stent deployment, clinical symptoms before and after the procedure, and complications were evaluated.ResultsTechnical success was achieved in all patients. No major complications were observed. Before treatment, two patients could not take any food and the gastric outlet obstruction scoring system (GOOSS) score was 0; the other four patients could take only liquids orally (GOOSS score = 1). After treatment, five patients could take soft food (GOOSS score = 2) and one patient could take a full diet (GOOSS score = 3). The mean duration of primary stent patency was 115.7 days.ConclusionsThe newly designed stent is associated with a high degree of technical success and good clinical outcome and may be clinically effective in the management of malignant distal duodenal obstruction.

  18. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  19. 'Ins' and 'outs' of triple therapy: Optimal antiplatelet therapy in patients on chronic oral anticoagulation who need coronary stenting.

    NARCIS (Netherlands)

    Dewilde, W.; Verheugt, F.W.A.; Breet, N.; Koolen, J.J.; Berg, J.M. ten

    2010-01-01

    Chronic oral anticoagulant treatment is obligatory in patients (class I) with mechanical heart valves and in patients with atrial fibrillation with CHADS2 score >1. When these patients undergo percutaneous coronary intervention with placement of a stent, there is also an indication for treatment

  20. Comparison of plastic and self-expandable metal stents in the palliative treatment of malignant biliary obstruction:a meta-analysis

    Institute of Scientific and Technical Information of China (English)

    Kui Li; Zhongyin Zhou; Ximing Xu; Hesheng Luo

    2014-01-01

    Stent-placement-is-one-of-the-main-methods-in-the-pal-iative-treatment-of-malignant-biliary-obstruc-tion,-including-plastic-and-self-expandable-metal-stents.-The-comparison-of-stent-patency-between-self-expandable-metal-and-plastic-stents-in-pal-iation-of-malignant-biliary-obstruction-is-meaningful.-We-carried-out-a-meta-analysis-to-summarize-current-evidence-for-clinical-ef-icacy-of-self-expandable-metal-and-plastic-stents-in-the-treatment-of-malignant-biliary-obstruc-tion.-Methods:A-comprehensive-search-of-several-databases-including-CNKI,-Wanfang-Data,-Sino-MED.-A-fixed-ef-ects-or-random-ef-ects-model-was-used-to-pool-data-of-al-study-endpoint.-Sensitivity-analysis-was-also-performed.-Results:Eight-randomized-clinical-trials-were-identified,-including-633-patients.-These-results-suggested-that-the-self-expandable-metal-stents-were-associated-with-a-significantly-longer-stent-patency-(OR=8.15;95%CI:2.80-23.76;I2=85%).-No-publication-bias-was-observed.-Conclusion:Self-expanding-metal-stents-have-a-longer-patency-than-plastic-stents-and-of-er-adequate-pal-iation-in-patients-with-malignant-biliary-obstruction.

  1. Fiducial Marker Placement

    Science.gov (United States)

    ... Media Computed Tomography (CT) - Body General Ultrasound Ultrasound - Prostate Introduction to Cancer Therapy (Radiation Oncology) Proton Therapy Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT) Images related to Fiducial Marker Placement Sponsored by ...

  2. The research application of endoscopic double stents for malignant obstructive jaundice%内镜下双支架联合治疗恶性梗阻性黄疸的探讨

    Institute of Scientific and Technical Information of China (English)

    董琳; 郭建阳; 黄允宁; 杨世杰; 杨勇

    2012-01-01

    目的 探讨金属支架联合塑料支架在治疗恶性梗阻性黄疸中的应用.方法 对42例行十二指肠镜下放置金属支架联合塑料支架的患者,与单纯放置金属支架41例及单纯放置塑料支架39例做比较,观察其生存时间及更换支架的次数.结果 十二指肠镜下放置金属支架联合塑料支架42例生存时间较后两者明显延长,同时可以更换金属支架内的塑料支架.结论 十二指肠镜下放置金属支架联合塑料支架在恶性梗阻性黄疸中解决了过去不能更换支架的困难.同时延长了患者的生存期.%Objective To investigate the application of metal and plastic stents for malignant obstructive jaundice. Methods Therapeutic efficacy was compared among the 42 cases of plastic and metal stent placement, 41 cases of metal stent placement and 39 cases of plastic stent placement under duodenoscopy. The survival time and the numbers of stent replacement were compared. Results The survival time in group of combined application of metal stent placed plastic stent was significantly longer than the two others. Moreover the plastic stents can be replaced within the metal stent. Conclusion The application of metal and plastic stents for malignant obstructive jaundice can solve the difficulty of stent replacement and extend the survival of patients.

  3. Blister-like aneurysms of the supraclinoid internal carotid artery: challenging endovascular treatment with stent-assisted coiling.

    Science.gov (United States)

    Ahn, Jung Yong; Cho, Jun Hyung; Jung, Jin Young; Lee, Byung Hee; Yoon, Pyeong Ho

    2008-09-01

    ''Blister-like'' aneurysms of the supraclinoid segment of the internal carotid artery are usually small and have fragile walls, necessitating special care to prevent rebleeding. These lesions are considered high-risk aneurysms because of the technical difficulties associated with their surgical and endovascular treatment. In this report, we describe the use of stent-assisted, repeated coil embolization in the treatment of a ruptured blister-like aneurysm that experienced rapid growth. Stent-assisted coil embolization is an alternative, but sometimes hazardous, treatment for select blister-like aneurysms. Careful serial follow-up angiography will provide documentation as to the long-term stability of the endovascularly treated blister-like aneurysm described here, but early results are encouraging. Alternatively, placement of telescoped stents or graft-stent devices offers promise for future endovascular therapy.

  4. Evaluation of Exercise-Induced Hypertension Post Endovascular Stenting of Coarctation of Aorta

    Directory of Open Access Journals (Sweden)

    Akbar Shah Mohammadi

    2010-08-01

    Full Text Available Background: Coarctation of the aorta (COA is a defect that accounts for 5-8% of all congenital heart diseases. Balloon angioplasty as a treatment for COA is increasingly performed, with endovascular stents having been proposed as a means of improving the efficacy and safety of the procedure. The aim of this study was to evaluate the systolic blood pressure gradient at rest and during maximal exercise at follow-up in patients post endovascular stenting of COA.Methods: Thirteen patients (4 native and 9 re-coarctation cases of COA after surgery or balloon angioplasty with a mean age of 11.1 ± 4.7 years underwent endovascular stenting between November 2007 and December 2009 via standard techniques for native COA as an alternative to surgical repair. Doppler echocardiography was performed pre and post stenting. Resting and exercise assessment of blood pressure was performed at follow-up.Results: Post stent implantation, no angiographic major complications were evident. Systolic blood pressure gradient decreased from 42 ± 8.8 mm Hg before stent placement to 7 ± 10 mm Hg at follow-up (p value < 0.001. Peak Doppler pressure gradient decreased from 30 ± 14 mm Hg to 14 ± 10 mm Hg at follow-up (p value < 0.007. One case of exerciseinduced hypertension was seen in patients.Conclusion: Endovascular stenting for native COA in older children and post-surgical COA repair in patients with residual COA and re-coarctation is a reasonable alternative to surgical correction. During early follow-up, stenting effectively alleviates the aortic arch obstruction with normalization of the systemic blood pressure both at rest and during maximal exercise.

  5. Sealing of Airway Fistulas for Metallic Covered Z-type Stents

    Directory of Open Access Journals (Sweden)

    Hongwu WANG

    2011-08-01

    Full Text Available Background and objective Treating airway fistulas, including esophagorespiratory fistulas (ERFs, bronchopleural fistulas (BPFs, and tracheomediastinal fistulas (TMFs, is difficult. The aim of this study is to evaluate the safety and clinical efficacy of metallic covered Z-type stents (CZTS for the treatment of airway fistulas through bronchoscopy or fluroscopy. Methods Thirty-eight patients with fistulas between the esophagus, mediastina, and airways (32 ERFs, 5 BPFs, and 1 TMF were retrospectively reviewed after treatment with covered metallic esophageal and airway stents. The fistulas were caused by esophageal (n=26, bronchogenic (n=11, and thyroid (n=1 carcinomas. Results Forty-six fistulas were found in 38 patients. The fistula size ranged from 0.5 cm to 7.0 cm. Forty airway covered metal stents (24 Y-type, 8 L-type, and 8 I-type and 24 esophageal metal stents were placed. Complete responses to the sealing effects of fistulas were noted in 4.3% of all the fistulas, 60.9% showed complete clinical responses, 23.9% showed partial responses, and 10.9% showed no response. An effectivity rate of 89.1% was observed, and the median survival duration of all patients was 5 months. Conclusion The use of CZTS appears to be safe and feasible for the palliative treatment of ERFs, BPFs, and TMFs. Airway stent placement is recommended for patients with ERF. In the event that airway stents fail, esophageal stents should be given. Airway bifurcation stents were observed to be especially suitable for the sealing of fistulas near the trachea carina.

  6. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    Energy Technology Data Exchange (ETDEWEB)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com [United BioSource Corporation, Peri- and Post-Approval Services (Spain); Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Department of Cardiovascular and Interventional Radiology (France); Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Cardiovascular Surgery Department (France); Lissovoy, Greg de, E-mail: gdelisso@jhsph.edu [Johns Hopkins Bloomberg School of Public Health, Department of Health Policy and Management (United States); Lopes, Sandra, E-mail: Sandra.Lopes@CookMedical.com [Cook Medical, Health Economics and Reimbursement (Denmark)

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  7. Efficiency of ultrasonography and CT angiography in follow-up studies of carotid stent and percutaneous transluminal angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Chang Woo; Lee, Byung Hee; Chung, Bong Sub; Ahn, Jung Yong; Heo, Kyung; Kho, Young Sik [Pundang CHA General Hospital, Pochon CHA Univ. College of Medicine, Pochon (Korea, Republic of)

    1999-12-01

    The aim of this study was to determine a more appropriate method for follow-up of carotid stenting by comparing the efficiency of US and CT angiography. Eleven carotid arteries of seven patients(men:5, women:2, mean age:56.4years) who underwent stent placement and percutaneous transluminal angioplasty(PTA) because of carotid stenosis were studied. The follow-up periods ranged from three to eleven (mean, five) months, and US and CT angiography were performed in one day. Color duplex sonography was performed with a 10 MHz linear array transducer. After spiral CT scan were obtained, MPR images were reconstructed on a workstation. Retrospective imaging analysis specifically focused on [1] stent configuration, [2] the accuracy of internal diameter measurement, [3] the detection of blood flow and the measurement of blood flow velocity, [4] the presence of atheroma and intraluminal thrombi, [5] the measurement of stent location, and [6] artifacts. US was more accurate than CT angiography for measuring internal diameter. In all cases, US and CT angiography were able to detect the blood flow at carotid artery, and utilizing the Doppler spectrum, flow velocity was measured. US showed atheromas in all cases but CT angiography demonstrated calcified atheromas in three cases only. In six cases, US failed to determine stent location, though in this respect CT angiography was successful in all cases. Artifacts of US were small reverberation artifact(11/11) of the stent and a defective color Doppler signal caused by acoustic shadowing of atheroma calcification(3/11). Artifacts of CT angiogrpahy were hardbeam artifact of the stent(11/11) and motion artifact(3/11). US was superior to CT angiography in accuracy of measuring stent diameter, hemodynamic assessment, high-resolution views of the luminal state of the stent and minimal artifacts for the non-invasive follow-up studies of carotid stenting.

  8. Present and future of endovascular SFA treatment: stents, stent-grafts, drug coated balloons and drug coated stents.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Verbist, J; Peeters, P

    2008-04-01

    The current evolution towards treating more complex femoropopliteal lesions as seen in the renewed TASC II recommendations clearly reflects the continuous evolutions in femoropopliteal stent design. Recent stent design improvements focus on decreasing stent fractures rates which can negatively impact patency rates. By rearranging strut alignment towards helical connecting bridges or full helical stent designs, stent designers have successfully improved the fracture resistance of their stents. The superior fracture resistance of the latest stent generation in combination with the production of long nitinol stents of up to 20 cm in length allow that more difficult and complex lesions can be treated endovascularly. The continuous perfection of nitinol stent platforms followed by the transfer of coronary technologies (e.g. active coatings) towards peripheral devices might broaden the indications for the minimal invasive strategy towards TransAtlantic Inter-Society Consensus (TASC) II C&D lesions.

  9. DJ stent - boon or curse?

    Directory of Open Access Journals (Sweden)

    AS Agrawal

    2014-04-01

    Full Text Available DJ stent is considered as a boon by the urologist but without proper knowledge it turns to be curse for the patient. We report a case of a 34 year old man who developed vesical calculus secondary to DJ stent in a short span of 6-8 months. He underwent cystolithotomy for removal of the vesical calculus along with the DJ stent. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-3, 55-59 DOI: http://dx.doi.org/10.3126/jcmsn.v9i3.10224  

  10. Effect of different stent configurations using Lattice Boltzmann method and particles image velocimetry on artery bifurcation aneurysm problem.

    Science.gov (United States)

    Mokhtar, N Hafizah; Abas, Aizat; Razak, N A; Hamid, Muhammad Najib Abdul; Teong, Soon Lay

    2017-08-24

    Proper design of stent for application at specific aneurysm effect arteries could help to reduce the issues with thrombosis and aneurysm. In this paper, four types of stent configuration namely half-Y (6 mm), half-Y (4 mm), cross-bar, and full-Y configuration will implanted on real 3D artery bifurcation aneurysm effected arteries. Comparisons were then conducted based on the flow patterns after stent placement using both LBM-based solver and PIV experimental findings. According to the data obtained from all 4 stent designs, the flow profiles and the computed velocity from both methods were in agreement with each other. Both methods found that half-Y (6 mm) stent configuration is by far the best configuration in reducing the blood velocity at the vicinity of the aneurysm sac. The analysis also show that the half-Y (6 mm) stent configuration recorded the highest percentage of velocity reduction and managed to substantially reduce the pressure at the bifurcation region. This high flow velocity reduction through the use of half-Y stent could consequently promote the formation of thrombus thereby reducing the risk of rupture in the aneurysm sac. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Self-expandable metallic stents for palliation of patients with malignant gastric outlet obstruction caused by stomach cancer

    Institute of Scientific and Technical Information of China (English)

    Tae Oh Kim; Dae Hwan Kang; Gwang Ha Kim; Jeong Heo; Geun Am Song; Mong Cho; Dong Heon Kim; Mun Sup Sim

    2007-01-01

    AIM: To ascertain clinical outcome and complications of self-expandable metal stents for endoscopic palliation of patients with malignant obstruction of the gastrointestinal (GI) tract.METHODS: A retrospective review was performed throughout August 2000 to June 2005 of 53 patients with gastric outlet obstruction caused by stomach cancer. All patients had symptomatic obstruction including nausea, vomiting, and decreased oral intake. All received self-expandable metallic stents.RESULTS: Stent implantation was successful in all 53 (100%) patients. Relief of obstructive symptoms was achieved in 43 (81.1%) patients. No immediate stent-related complications were noted. Seventeen patients had recurrent obstruction (tumor ingrowth in 14 patients, tumor overgrowth in 1 patient, and partial distal stent migration in 2 patients). The mean survival was 145 d. Median stent patency time was 187 d.CONCLUSION: Endoscopic placement of self-expandable metallic stents is a safe and effective treatment for the palliation of patients with inoperable malignant gastric outlet obstruction caused by stomach cancer.

  12. Prospective multi-center registry to evaluate efficacy and safety of the newly developed diamond-like carbon-coated cobalt-chromium coronary stent system.

    Science.gov (United States)

    Ando, Kenji; Ishii, Katsuhisa; Tada, Eiji; Kataoka, Kazuaki; Hirohata, Atsushi; Goto, Kenji; Kobayashi, Katsuyuki; Tsutsui, Hiroshi; Nakahama, Makoto; Nakashima, Hitoshi; Uchikawa, Shinichiroh; Kanda, Junji; Yasuda, Satoshi; Yajima, Junji; Kitabayashi, Hiroshi; Sakurai, Shumpei; Nakanishi, Keita; Inoue, Naoto; Noike, Hirofumi; Hasebe, Terumitsu; Sato, Tetsuya; Yamasaki, Masao; Kimura, Takeshi

    2017-07-01

    The purpose of this multi-center, non-randomized, and open-label clinical trial was to determine the non-inferiority of diamond-like carbon (DLC)-coated cobalt-chromium coronary stent, the MOMO DLC coronary stent, relative to commercially available bare-metal stents (MULTI-LINK VISION(®)). Nineteen centers in Japan participated. The study cohort consisted of 99 patients from 19 Japanese centers with single or double native coronary vessel disease with de novo and restenosis lesions who met the study eligibility criteria. This cohort formed the safety analysis set. The efficacy analysis set consisted of 98 patients (one case was excluded for violating the eligibility criteria). The primary endpoint was target vessel failure (TVF) rate at 9 months after stent placement. Of the 98 efficacy analysis set patients, TVF occurred in 11 patients (11.2 %, 95 % confidence interval 5.7-19.2 %) at 9 months after the index stent implantation. The upper 95 % confidence interval for TVF of the study stent was lower than that previously reported for the commercially available MULTI-LINK VISION(®) (19.6 %), demonstrating non-inferiority of the study stent to MULTI-LINK VISION(®). All the TVF cases were related to target vascular revascularization. None of the cases developed in-stent thrombosis or myocardial infarction. The average in-stent late loss and binary restenosis rate at the 6-month follow-up angiography were 0.69 mm and 10.5 %, respectively, which are lower than the reported values for commercially available bare-metal stents. In conclusion, the current pivotal clinical study evaluating the new MOMO DLC-coated coronary stent suggested its low rates of TVF and angiographic binary restenosis, and small in-stent late loss, although the data were considered preliminary considering the small sample size and single arm study design.

  13. Colorectal Cancer Prevention

    Science.gov (United States)

    ... alcoholic beverages per day increases the risk of colorectal cancer. Drinking alcohol is also linked to the risk of forming large colorectal adenomas (benign tumors). Cigarette smoking Cigarette smoking is ...

  14. Evaluating Stent Optimisation Technique (StentBoost®) in a Dedicated Bifurcation Stent (the Tryton™)

    Energy Technology Data Exchange (ETDEWEB)

    Fysal, Zamil; Hyde, Thomas; Barnes, Edward; McCrea, William; Ramcharitar, Steve, E-mail: steve.ramcharitar@chem.ox.ac.uk

    2014-03-15

    Background/Purpose: To evaluate the use of StentBoost® in the Tryton™ dedicated SideBranch Stent. Methods and Results: The Tryton™ SideBranch Stent has been effectively used to manage complex bifurcations. However, the paucity of scaffolding in the proximal part of the stent makes it often difficult to visualise under standard radiographic imaging. We set out to evaluate whether by using an augmented radiographic imaging technique it was possible to aid visualisation of the stent. In particular the so call 'wedding ring' band which is crucial to the procedural success. We further evaluated whether it was possible to determine the apposition of the stent at the carina, its coverage and the ability to aid recrossing of the struts closest to the carina as well as the added radiation exposure. Conclusions: StentBoost® was found to be invaluable to the procedural success of the Tryton™ deployment without adding any extra cost to the procedure and with only a 3.7% increase in radiation to the patient. It allowed enhanced visualisation in all cases to aid apposition, recrossing and coverage.

  15. Vertebral artery origin stenting with buddy wire technique in tortuous subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Kizilkilic, Osman [Baskent University Department of Radiology, Adana Teaching and Medical Research Center, 01170 Yuregir-Adana (Turkey)]. E-mail: ebos90@hotmail.com

    2007-01-15

    Catheterization of vessels with severe tortuosity and atherosclerotic changes may represent a technical challenge and is associated with a higher incidence of vascular complications [Putman CM, Chaloupka JC. Use of large-caliber coronary guiding catheters for neurointerventional applications. AJNR Am J Neuroradiol 1996;17:697-704]. Placement of guiding catheter to the tortuous subclavian artery in vertebral artery origin stenting procedure is such a condition with difficulties. In the presence of severe tortuosity of aortic arch and proximal subclavian artery placement of guiding catheter may be difficult and yield poor backup support. We describe a technique that uses a buddy wire to make the guiding catheter stable in its proper position and make possible to perform stenting the vertebral artery origin stenosis.

  16. A case of stenotic change from gastric candidiasis managed with temporary stent insertion.

    Science.gov (United States)

    Joo, Moon Kyung; Park, Jong-Jae; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2011-06-01

    Invasive gastric Candida infection in patient with co-morbidity can cause stenotic change if it is developed at anatomically narrowing portion, such as distal antrum, pylorus, or duodenal bulb. However, proper management of benign stenosis by diffuse gastric Candidasis is still under controversy and palliative bypass surgery has several shortcomings because high risk operative group may be included in this case. Palliative placement of self-expandable metallic stent has been settled as a standard management of malignant gastric pyloric obstruction and it is expected to be applied in benign stenotic lesions due to its gradual dilation effect. We described a case of stenosis by diffuse gastric Candidasis at anastomosis of subtotal gastrectomy, which was managed by temporary placement of self-expandable metallic stent.

  17. Technical and Clinical Outcomes Following Colonic Stenting: A Seven-Year Analysis of 268 Procedures.

    Science.gov (United States)

    Little, M W; Oakley, T; Briggs, J H; Sutcliffe, J A; Allouni, A K; Makris, G; Bratby, M J; Tapping, C R; Patel, R; Wigham, A; Anthony, S; Phillips-Hughes, J; Uberoi, R

    2016-10-01

    To assess the factors contributing to the technical and clinical success of colorectal stenting for large bowel obstruction. 268 cases of colonic stenting for large bowel obstruction were performed in 249 patients of mean age of 72 years (28-98) between 2006 and 2013. The majority of strictures were due to malignant disease, 244/268 (91 %). Diverticular strictures accounted for 24/268 (9 %). Overall technical success rate was 81 % (217/268), with a clinical success rate of 65 % (174/268). Duration of symptoms ranged from 0 to 180 days (mean 8 days). Technical success rate was seen to decrease with increasing symptom duration. For symptom duration of less than 1 week, technical success was 85.4 % (181/212) versus 69.6 % (39/56) for those with symptoms of greater than a week (p < 0.05). Clinical success rates fell from 71.3 % (107/150) to 59.3 % (70/118) (p < 0.05) when attempting to stent lesions of greater than 5 cm. There was also a significant reduction in clinical success when stenting lesions on a bend rather than a straight segment of colon 75.7 % (109/144) versus 59.7 % (74/124) (p < 0.05). A total of 20 (7.46 %) perforations were identified during the study. Stent migration occurred in 6.6 % of cases. In-stent stenosis occurred in 3.3 %. The overall 30-day all cause mortality rate was 9 %. Lesion size, location and duration of obstructive symptoms are statistically significant determinants of patient outcome. These factors could be used to advise patient selection for colonic stenting or direct progression to surgical intervention.

  18. 电子支气管镜下覆膜气道支架置入术治疗肿瘤性食管气管瘘的护理%Nursing of electronic bronchoscope covered airway stent placement for the treatment of malignant esophageal fistula

    Institute of Scientific and Technical Information of China (English)

    杨柳

    2012-01-01

    目的:探讨在电子支气管镜下进行覆膜气道支架置入术对治疗肿瘤性食管气管瘘患者的手术前、手术中及手术后的方法,以提高肿瘤性食管气管瘘的患者的生活质量及延长生存时间,减少术后的并发症.方法:通过积极的术前护理,局部麻醉,术中配合,及术中心电、血压、指脉氧监测,注重术后护理和并发症的预防.结果:32例肿瘤性食管气管瘘患者均放置成功,覆膜气道支架置入术后,呛咳及肺部感染情况明显好转,生活质量明显提高,术后呼吸困难改善,未发生大咯血及支架移位等严重并发症.结论:积极的术前准备和心理护理,术中的严密监护和积极配合,减少并发症的发生是电子支气管镜下覆膜气道支架置入术成功的关键.%Objective: To investigate the metheds of preoperative, intraoperative, and postoperative care in the treatment of neoplastic esophagotracheal fistula surgery by the airway membrana tectoria cochleae stents, in order to improve the quality of life and prolong survival time of patients with neoplastic esophagotracheal fistula,reduce postoperative complication. Methods: We investigated the effect of nursing through positive preoperative nursing,local anesthesia,operative cooperation,monitoring with the intraoperative electrocardiogram,blood pressure,oxygen saturation,positive post -operative nursing,and the prevention of complications. Results: All 32 cases of neoplastic esophagotracheal fistula patients were successfully placed airway stents. after these operation, we found excellent nursing could markedly reduce cough and lung infections,significantly improve the quality of life,improve the postoperative respiratory difficulties , eliminate the occurrence of massive hemoptysis and stent migration. Conclusion: Through positive preoperative preparation and psychological nursing, intensive intraoperative care and actively operative cooperation,and the prevention of

  19. The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-04-15

    We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint

  20. Management Of Encrusted Ureteral stents

    African Journals Online (AJOL)

    imac-3

    Objectives: To present our experience in managing encrusted ureteral stents and to review the .... A single anesthetic session was required in 18 patients (81.8%) and ... fluid intake, chemotherapy-induced hyperuricosuria, persistent or.

  1. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  2. A Case of Stenotic Change from Gastric Candidiasis Managed with Temporary Stent Insertion

    OpenAIRE

    Joo, Moon Kyung; Park, Jong-Jae; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2011-01-01

    Invasive gastric Candida infection in patient with co-morbidity can cause stenotic change if it is developed at anatomically narrowing portion, such as distal antrum, pylorus, or duodenal bulb. However, proper management of benign stenosis by diffuse gastric Candidasis is still under controversy and palliative bypass surgery has several shortcomings because high risk operative group may be included in this case. Palliative placement of self-expandable metallic stent has been settled as a stan...

  3. Product Placement in Cartoons

    Directory of Open Access Journals (Sweden)

    Irena Oroz Štancl

    2014-06-01

    Full Text Available Product placement is a marketing approach for integrating products or services into selected media content. Studies have shown that the impact of advertising on children and youth are large, and that it can affect their preferences and attitudes. The aim of this article is to determine the existing level of product placement in cartoons that are broadcast on Croatian television stations. Content analysis of cartoons in a period of one month gave the following results: in 30% of cartoons product placement was found; most product placement were visual ads, in 89%, however, auditory product placement and plot connection was also found. Most ads were related to toys and it is significant that even 65% of cartoons are accompanied by a large amount of products available on the Croatian market. This is the result of two sales strategies: brand licensing (selling popular cartoon characters to toys, food or clothing companies and cartoon production based on existing line of toys with the sole aim of making their sales more effective.

  4. Anchor-wire technique for multiple plastic biliary stents to prevent stent dislocation

    Institute of Scientific and Technical Information of China (English)

    Tsuyoshi Hamada; Kazuhiko Koike; Yousuke Nakai; Saburo Matsubara; Hiroyuki Isayama; Akiko Narita; Kazuhiro Watanabe; Yukihiro Koike; Shigeo Matsukawa; Tateo Kawase

    2011-01-01

    In endoscopic placement of multiple plastic biliary stents (PBSs), we sometimes experience proximal dislocation of the first PBS at the time of subsequent PBS insertion. We describe the case of a 79-year-old male with obstructive jaundice caused by cholangiocarcinoma who needed to receive multiple PBS placements for management of cholangitis. Although proximal dislocation of the first PBS was observed, we prevented the dislocation via our technique of using guidewire inserted from the distal end of the first PBS to the side hole as the anchor-wire. We could complete this technique only by inserting guidewire through the side hole of the first PBS during the process of releasing the first PBS and pulling out the guidewire and the inner sheath. It did not matter whether the anchor-wire went towards the third portion of the duodenum or the duodenal bulb. Here we introduce this "anchor-wire technique", which is useful for the prevention of PBS proximal dislocation in placing multiple PBSs.

  5. Novel side branch ostial stent.

    Science.gov (United States)

    Chen, Shao-Liang; Lv, Shu-Zheng; Kwan, Tak W

    2009-04-01

    Bifurcation lesions are technically challenging and plagued by a high incidence of restenosis, especially at the side branch orifice, which results in a more frequent need for revascularization during the follow-up period. This report discusses two clinical experiences with a novel side branch ostial stent, the BIGUARD stent, designed for the treatment of bifurcation lesions; procedural success with no in-hospital complications was observed in types IVb and Ia lesions.

  6. Self-expandable metallic stents in the treatment of post-esophagogastrostomy/post-esophagoenterostomy fistula.

    Science.gov (United States)

    Nowakowski, P; Ziaja, K; Ludyga, T; Kuczmik, W; Biolik, G; Cwik, P; Ziaja, D

    2007-01-01

    Esophageus or gaster resection in patients with malignant disease is still a treatment of choice. It is obvious that each surgical procedure in these patients carries some possibility of complications. Esophageo-gastric or esophageo-jejuno anastomosis has a 4-27% frequency of fistula occurrence. All these result in 65% mortality in cases of poorer prognosis. The aim of this paper is not to present all types of complications but to objectively analyse the usefulness of the covered stent placement in the treatment of anastomotic fistulas. We present six patients who were treated for postoperative fistula of esophageo-gastric anastomosis (1 case) or esophageo-jejuno anastomosis (5 cases). All patients were treated with stapler suture for digestive tract reconstruction after malignancy removal during the primary surgical procedure. Signs and symptoms of suture leak between 5-8 days post-surgery were observed. Conservative therapy was not effective. Thus a new method of treatment was employed - covered stent placement. The procedure was performed under X-ray control. In all treated patients there was change for the better and quick reduction of secretion from the fistulas was observed. All patients were discharged from the department after several days and all had survived at 30 days follow-up. Covered esophageal stent placement seems to be a safe and promising method of treatment for patients with anastomotic fistula which significantly reduces mortality and improves quality of live. Our experiences confirms that of other investigators.

  7. Inappropriateness in biliary stenting

    Directory of Open Access Journals (Sweden)

    Giuseppe Chesi

    2013-10-01

    Full Text Available Starting from a real case of a 69-year old patient affected by cholangiocarcinoma, we intend to discuss the accuracy and appropriateness of the diagnostic and therapeutic procedures adopted. This case shows in particular that a more accurate preoperative staging could probably avoid the patient unnecessary laparotomy. According to the indications in the medical literature, this patient could possibly benefit from chemotherapy, but a chemoembolization of liver metastases was performed. However in the literature no available evidence suggests that this treatment would be beneficial in this kind of clinical picture. Eventually, when the disease was already at an advanced stage and worsened due to a necrosis of the left hepatic lobe and a cholangitic infection, a repositioning of the stent on the stent was performed, despite in the literature the life expectancy cut-off for this procedure is at least 6 months. We also discuss the communication between the physician, the patient and the family, which was probably based on overly optimistic and unrealistic expectations. This led to a number of surgical procedures, which were not certainly helpful and indeed were probably even harmful for this patient. In addition, these procedures caused unnecessary costs borne by the healthcare system. In conclusion, we advocate that discussion and self-assessment must be always promoted, so that the healthcare professionals can review the process and the outcome of their treatment as well as their behavior to understand if it could have been more appropriate to offer actual benefits to the patients in terms of better quality of life and longer life expectancy.

  8. Steerable antegrade stenting: a new trick of the trade

    Directory of Open Access Journals (Sweden)

    Udo Nagele

    2007-06-01

    Full Text Available INTRODUCTION: Whereas a retrograde attempt to insert an indwelling stent is performed in lithotomy position, usually renal access is gained in a prone position. To overcome the time loss of patient repositioning, a renal puncture can be performed in a modified lithotomy position with torqued truncus and slightly elevated flank. There is a two-fold advantage of this position: transurethral and transrenal access can be obtained using a combined approach. In the present study, this simple technique is used to position a floppy guide wire through a modified needle directly through the renal pelvis into the ureter. MATERIALS AND METHODS: The kidney is punctured in the modified lithotomy position under sonographic control using an initial three-part puncture needle. A floppy tip guide-wire is inserted into the collecting system via the needle after retrieving the stylet. The retracted needle is bent at the tip while the guide-wire is secured in the needle and the collecting system. The use of the floppy tip guide-wire helps to insert the curved needle back into the kidney pelvis, which becomes the precise guidance for the now steerable wire. The desired steerable stent is positioned under radiographic control in a retrograde fashion over the endoscopically harbored tip of the guide-wire. Two patient cohorts (newly described method and conventional method were compared. RESULTS: The presented steering procedure saves 16.5 mean minutes compared to the conventional antegrade stenting and 79.5 Euros compared to the control group. CONCLUSION: The described combined antegrade-retrograde stent placement through a bent three-part puncture needle results in both clinical superiority (OR time, success rate and financial benefits.

  9. Coronary aneurysm and very late stent thrombosis formation associated with sirolimus-eluting stent implantation

    Institute of Scientific and Technical Information of China (English)

    XIE Hong-zhi; ZHANG Shu-yang; ZENG Yong; SHEN Zhu-jun; FANG Quan

    2009-01-01

    @@ Since drug-eluting stents (DES) can significantly reduce the risk of instant restenosis compared with bare-metal stents, they have been widely used in interventional therapy for coronary heart disease. With bare-metal stents being rapidly replaced by DES there is a great concern about the safety of DES due to stent thrombosis.~(1,2)

  10. Can Doppler flow parameters of carotid stenosis predict the occurrence of new ischemic brain lesions detected by diffusion-weighted MR imaging after filter-protected internal carotid artery stenting?

    Science.gov (United States)

    Gunduz, Y; Akdemir, R; Ayhan, L T; Keser, N

    2014-04-01

    Carotid angioplasty and stent placement are increasingly being used for the treatment of symptomatic and asymptomatic carotid artery disease. Carotid angioplasty and stent placement carry an inherent risk of distal cerebral embolization, precipitating new brain ischemic lesions and neurologic symptoms. Our purpose was to evaluate the frequency of new ischemic lesions found on diffusion-weighted imaging after protected carotid angioplasty and stent placement and to determine the association of new lesions with ICA Doppler flow parameters. Fifty-two patients (mean age, 68 ± 11 years) with 50%-69% (n = 20, group 1) and ≥70% (n = 32, group 2) internal carotid artery stenosis underwent carotid angioplasty and stent placement with distal filter protection. DWI was performed before and 48 hours after carotid angioplasty and stent placement. Thirty-three (63.4%) patients showed new lesions. The average number of new postprocedural lesions was 3.4 per patient. Most of the postprocedural lesions were <5 mm (range, 3-23 mm), cortical and corticosubcortical, and clinically silent. Group 2 had a significantly higher number of new lesions compared with group 1 (P < .001). A significant relationship was found between ICA Doppler flow parameters and the appearance of new lesions. The appearance of new ischemic lesions was significantly related to the Doppler flow parameters, particularly peak systolic velocity.

  11. Treatment of malignant digestive tract obstruction by combined intraluminal stent installation and intra-arterial drug infusion

    Institute of Scientific and Technical Information of China (English)

    Ai-Wu Mao; Zhong-Du Gao; Jia-Yu Xu; Ren-Jie Yancg; Xiang-Seng Xiao; Ting-Hui Jiang; Wei-Jun Jiang

    2001-01-01

    AIM To study the palliative treatment of malignant obstrution of digestive tract with placement of intraluminal stent combined with intra-arterial infusion of chemotherapeutic drugs. METHODS A total of 281 cases of digestive tract malignant obstruction were given per oral (esophagus,stomach, duodenum and jejunum), per anal (colon and rectum ) and percutaneous transhepatic ( biliary )installation of metallic stent. Among them, 205 cases received drug infusion by cannulation of tumor supplying artery with Seldingers technique. RESULTS Altogether 350 stents were installed in 281 cases, obstructive symptoms were relieved or ameliorated after installation. Occurrence of restenotic obstruction was 8 - 43 weeks among those with intraarterial drug infusion, which was later than 4 - 26 weeks in the group with only stent installation. The average survival time of the former group was 43 (3 - 105) weeks,which was significantly longer than 15 (3- 24) weeks of the latter group. CONCLUSION Intraluminal placement of stent combined with intra-arterial infusion chemotherapy is one of the effective palliative therapies for malignant obstruction of the digestive tract with symptomatic as well as etiological treatment.

  12. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Stambo, Glenn W. [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)], E-mail: xraydoc2@yahoo.com; Leto, John [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 3001 W. Dr. Martin Luther King Jr. Blvd., Tampa, FL 33607 (United States); George, Christopher [Department of Hematology and Oncology, St. Joseph' s Hospital and Medical Center, 4301 W. Habana Avenue, Suite 1, Tampa, FL 33607 (United States); Van Epps, Kelly; Woeste, Troy; Berlet, Mathew [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)

    2008-05-15

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus.

  13. Very late coronary aneurysm formation with subsequent stent thrombosis secondary to drug-eluting stent

    Institute of Scientific and Technical Information of China (English)

    Ibrahim Akin,; Stephan Kische; Tim C Rehders; Henrik Schneider; G(o)kmen R Turan; Tilo Kleinfeldt; Jasmin Ortak; Christoph A. Nienaber; Hüseyin Ince

    2011-01-01

    Drug-eluting stents have changed the practice in interventional cardiology.With the widespread use of these stents important safety concerns regarding stent thrombosis and formation of coronary artery aneurysm have been expressed.While the majority of attention was focused on stent thrombosis,the formation of coronary aneurysm was only described in anecdotal reports.We report on a patient who suffered from very late stent thrombosis in association with coronary artery aneurysm formation secondary to drug-eluting stent but not to bare-metal stent.

  14. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    Energy Technology Data Exchange (ETDEWEB)

    Stoupis, Christoforos [University of Berne, Inselspital, Department of Diagnostic, Interventional and Pediatric Radiology, Berne (Switzerland); Kreisspital, Radiology, Maennedorf (Switzerland); Ludwig, Karin; Triller, Juergen [University of Berne, Inselspital, Department of Diagnostic, Interventional and Pediatric Radiology, Berne (Switzerland); Inderbitzin, Daniel [University of Berne, Inselspital, Clinic for Visceral and Transplantation Surgery, Berne (Switzerland); Do, Dai-Do [University of Berne, Inselspital, Clinic for Angiology, Berne (Switzerland)

    2007-02-15

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  15. Gastroduodenal Outlet Obstruction and Palliative Self-Expandable Metal Stenting: A Dual-Centre Experience

    Directory of Open Access Journals (Sweden)

    Nik S. Ding

    2013-01-01

    Full Text Available Background. Self-expandable metal stents (SEMs are increasingly being utilised instead of invasive surgery for the palliation of patients with malignant gastroduodenal outlet obstruction. Aim. To review two tertiary centres’ experience with placement of SEMs and clinical outcomes. Methods. Retrospective analysis of prospectively collected data over 12 years. Results. Ninety-four patients (mean age, 68; range 28–93 years underwent enteral stenting during this period. The primary tumour was gastric adenocarcinoma in 27 (29% patients, pancreatic adenocarcinoma in 45 (48%, primary duodenal adenocarcinoma in 8 (9%, and cholangiocarcinoma and other metastatic cancers in 14 (16%. A stent was successfully deployed in 95% of cases. There was an improvement in gastric outlet obstruction score (GOOS in 84 (90% of patients with the ability to tolerate an enteral diet. Median survival was 4.25 months (range 0–49 without any significant differences between types of primary malignancy. Mean hospital stay was 3 days (range 1–20. Reintervention rate for stent related complications was 5%. Conclusion. The successful deployment of enteral stents achieves excellent palliation often resulting in the prompt reintroduction of enteral diet and early hospital discharge with minimal complications and reintervention.

  16. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, Nicholas, E-mail: nicholas.chalmers@cmft.nhs.uk [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Walker, Paul T. [James Cook University Hospital, Department of Radiology (United Kingdom); Belli, Anna-Maria [St. George' s Healthcare NHS Trust, Department of Radiology (United Kingdom); Thorpe, Anthony P. [Aberdeen Royal Infirmary, Department of Radiology (United Kingdom); Sidhu, Paul S. [King' s College Hospital, Department of Radiology (United Kingdom); Robinson, Graham [Hull Royal Infirmary, Department of Radiology (United Kingdom); Ransbeeck, Mariella van [Johnson and Johnson Medical NV/SA, Cordis (Belgium); Fearn, Steven A. [Johnson and Johnson Medical Ltd., Cordis (United Kingdom)

    2013-04-15

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  17. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    Science.gov (United States)

    Kwon, Chang-Il; Lehman, Glen A.

    2016-01-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422

  18. Preventive role of palladium-103 radioactive stent on in-stent restenosis in rabbit iliac arteries

    Institute of Scientific and Technical Information of China (English)

    LUO Quan-Yong; CHEN Li-Bo; YUAN Zhi-Bin; LU Han-Kui; ZHU Rui-Sen

    2005-01-01

    The abilility of γ-emitting palladium-103 stent implantation to inhibit in-stent restenosis in rabbit iliac arteries was investigated. Quantitative histomorphometry of the stented iliac segments 28 days after the implantation indicated that palladium-103 stents made a significant reduction in neointimal area and percent area stenosis compared with the nonradioactive stents. Lumen area in the palladium-103 stents treatment group was larger than the control group. However, the reduction of neointima formation by palladium-103 stents implantation was in a non-dose-dependent fashion. Low ionizing radiation doses via γ-emitting palladiurn-103 stent are effective in preventing neointimal hyperplasia in iliac arteries of rabbits. Palladium-103 stents can be employed as a possible novel means to prevent in-stent restenosis.

  19. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted;

    2012-01-01

    of death (HR=2.71 [95% CI: 1.72-4.27]) compared to cases without stent thrombosis. In-stent restenosis had no substantial impact (HR=1.17 [95% CI: 0.79-1.75]). However, in-stent restenosis presenting as non-ST-segment elevation myocardial infarction (NSTEMI) was associated with a greater mortality risk...

  20. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2017-07-19

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I (2) = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I (2) = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  1. Double-J Versus External Ureteral Stents in Kidney Transplantation: A Retrospective Analysis

    Directory of Open Access Journals (Sweden)

    Vogel

    2015-07-01

    Full Text Available Background Kidney transplantation has long been recognized as the best available therapy for end stage kidney disease. Objectives This study aimed to compare outcomes of double-J versus percutaneous ureteral stent placement in renal transplantation. Patients and Methods A retrospective analysis was performed on data of renal transplantations performed at our institution in a 12-month period. In this period, external and double-J stents were used in parallel. Length of hospital stay and stent-associated complications were evaluated. Results In 76 kidney transplants, 43 external (group 1 and 33 double-J (group 2 urinary stents were used. No significant difference was observed in the number of urinary tract infections, ureteric stenosis or necrosis. The mean overall length of hospital stay was comparable in both groups (20.7 days in group 1 vs 19.3 days in group 2, P = 0.533. For patients without immunological complications, the hospital stay was significantly reduced using double-J stents (12.9 days in group 1, 10.8 days in group 2, P = 0.018. Leakage of the ureteroneocystostomy occurred in 6 out of 43 patients in group 1 (13.9%. No case of anastomotic insufficiency was observed in group 2 (P = 0.035. Macrohematuria was detected in 13 out of the 43 patients in group 1 (30.2%, compared to 3 out of 33 patients in group 2 (9.1%; P = 0.045. Conclusions This nonrandomized comparison of stent types in kidney transplantation supports the use of prophylactic double-J stents in terms of decreased ureteric complications and reduced length of hospital stay.

  2. Multiplanar and two-dimensional imaging of central airway stenting with multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Ozgul Mehmet

    2012-08-01

    Full Text Available Abstract Background Multidetector computed tomography (MDCT provides guidance for primary screening of the central airways. The aim of our study was assessing the contribution of multidetector computed tomography- two dimensional reconstruction in the management of patients with tracheobronchial stenosis prior to the procedure and during a short follow up period of 3 months after the endobronchial treatment. Methods This is a retrospective study with data collected from an electronic database and from the medical records. Patients evaluated with MDCT and who had undergone a stenting procedure were included. A Philips RSGDT 07605 model MDCT was used, and slice thickness, 3 mm; overlap, 1.5 mm; matrix, 512x512; mass, 90 and kV, 120 were evaluated. The diameters of the airways 10 mm proximal and 10 mm distal to the obstruction were measured and the stent diameter (D was determined from the average between D upper and D lower. Results Fifty-six patients, 14 (25% women and 42 (75% men, mean age 55.3 ± 13.2 years (range: 16-79 years, were assessed by MDCT and then treated with placement of an endobronchial stent. A computed tomography review was made with 6 detector Philips RSGDT 07605 multidetector computed tomography device. Endobronchial therapy was provided for the patients with endoluminal lesions. Stents were placed into the area of stenosis in patients with external compression after dilatation and debulking procedures had been carried out. In one patient the migration of a stent was detected during the follow up period by using MDCT. Conclusions MDCT helps to define stent size, length and type in patients who are suitable for endobronchial stinting. This is a non-invasive, reliable method that helps decisions about optimal stent size and position, thus reducing complications.

  3. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Sinan [Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Hospital, Department of Radiology, Istanbul (Turkey)]. E-mail: sinan.sahin@e-kolay.net; Cimsit, Cagatay [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Andac, Nurten [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Baltacioglu, Feyyaz [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Tuglular, Serhan [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey); Akoglu, Emel [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey)

    2006-01-15

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions.

  4. Course Placement Study.

    Science.gov (United States)

    Fredericksen, Marlene; Slark, Julie

    Following the implementation of a matriculation plan at Rancho Santiago College (RSC), a study was conducted to examine the appropriateness of student course placement as assessed by faculty and students and to investigate faculty's perceptions of changes in students' skill level preparation over the past few years. Questionnaires were completed…

  5. Colonic stenting as a bridge to surgery in malignant large-bowel obstruction: a report from two large multinational registries

    DEFF Research Database (Denmark)

    Jiménez-Pérez, J; Casellas, J; García-Cano, J

    2011-01-01

    To date, this is the largest prospective series in patients with malignant colorectal obstruction to evaluate the effectiveness and safety of colonic self-expanding metal stents (SEMSs) as an alternative to emergency surgery. SEMSs allow restoration of bowel transit and careful tumor staging in p...... in preparation for elective surgery, hence avoiding the high morbidity and mortality associated with emergency surgery and stoma creation....

  6. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  7. Temporary self-expanding metallic stents for achalasia: A prospective study with a long-term follow-up

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively.RESULTS: Stent placement was successful in all patients....

  8. 'Ins' and 'outs' of triple therapy: Optimal antiplatelet therapy in patients on chronic oral anticoagulation who need coronary stenting.

    Science.gov (United States)

    Dewilde, W; Verheugt, F W A; Breet, N; Koolen, J J; Ten Berg, J M

    2010-09-01

    Chronic oral anticoagulant treatment is obligatory in patients (class I) with mechanical heart valves and in patients with atrial fibrillation with CHADS2 score >1. When these patients undergo percutaneous coronary intervention with placement of a stent, there is also an indication for treatment with aspirin and clopidogrel. Unfortunately, triple therapy is known to increase the bleeding risk. For this group of patients, the bottom line is to find the ideal therapy in patients with indications for both chronic anticoagulation therapy and percutaneous intervention to prevent thromboembolic complications such as stent thrombosis without increasing the risk of bleeding. (Neth Heart J 2010;18:444-50.).

  9. Visualization of Stent Lumen in MR Imaging: Relationship with Stent Design and RF Direction

    Directory of Open Access Journals (Sweden)

    Ohno,Seiichiro

    2012-06-01

    Full Text Available Magnetic resonance imaging (MRI visualization of metallic stent lumens is possible if the stent structure counteracts eddy currents in the lumen induced by the radio frequency magnetic field, B1. To examine the effectiveness of various stent designs in counteracting eddy currents, we anchored eight copper stent models and 2 commercially available nickel-titanium alloy (Nitinol stents in a gel phantom, perpendicular or parallel to the direction of B1. A mesh stent lumen showed hypointensity irrespective of its alignment relative to B1. A solenoid stent lumen showed hypointensity with the stent axis parallel to B1, but it had the same signal intensity as outside the lumen when perpendicular to B1. A Moebius stent lumen showed no signal reduction, irrespective of alignment relative to B1. Lumens of the commercially available stents showed hypointensity regardless of alignment relative to B1. Computer simulation revealed that the signal intensities of the stents corresponded to magnetic flux densities of B1 in the stents, which are modified by the structure of the stent. While in vivo MRI viewing of a Moebius stent lumen is likely possible regardless of axis alignment, inherent structural weakness may be problematic. As a more practical choice, the solenoid stent is easier to manufacture and generates no hypointensive signal when the axis is parallel to B0.

  10. Refining stent technologies for femoral interventions.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Callaert, J; Maene, L; Keirse, K; Verbist, J; Peeters, P

    2012-08-01

    Stents were created as a mechanical scaffold to prevent vessel recoil and luminal renarrowing after percutaneous transluminal angioplasty (PTA). In femoropopliteal arteries, indication for stent implantation remains a topic much debated on, especially in long lesion configurations. Ever since the first stents were introduced on the market, in-stent restenosis (ISR) has been an important issue. The evolution in stent design has known a major progression in the last decades from the first generation of stents, plagued with high fracture rates and low primary patency rates, to the design of newer stents to tackle these outcomes. More flexible and longer stents decreased the high fracture rates and drug-eluting stents offered a solution to the restenosis rates by local drug application. The difficult recrossibility of the lesion because of the presence of a permanent vascular scaffold is an obstacle that the drug-coated balloon (DCB) overcomes. Future perspectives in the treatment of femoropopliteal lesions are found in the bioresorbable stent implantation. The bioresorbable stent combines the advantages of a drug-eluting scaffolding stent without the remainder of a foreign object in the long-term. Further investigations in this area will eventually evolve in the creation of a superior endovascular treatment modality with high long-term patency rates and minimal detriments.

  11. Migration of forgotten stent into renal pelvis.

    Science.gov (United States)

    Giridhar, Venkatesh; Natarajan, Kumaresan; Hegde, Padmaraj

    2011-04-01

    Stent migration is a well recognized complication of forgotten stents, but migration into the renal pelvis is rarely documented. We present a case of migration and coiling of a forgotten stent in the renal pelvis, and discuss briefly, the etiological factors for the phenomenon and associated problems in management.

  12. 21 CFR 884.3900 - Vaginal stent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or...

  13. Incidence and predictors of coronary stent thrombosis

    DEFF Research Database (Denmark)

    D'Ascenzo, Fabrizio; Bollati, Mario; Clementi, Fabrizio

    2013-01-01

    Stent thrombosis remains among the most feared complications of percutaneous coronary intervention (PCI) with stenting. However, data on its incidence and predictors are sparse and conflicting. We thus aimed to perform a collaborative systematic review on incidence and predictors of stent...

  14. What to Expect After a Stent Procedure

    Science.gov (United States)

    ... time after the stent procedure. Your doctor will let you know when you can go back to your normal activities. Metal detectors used in airports and other screening areas don't affect stents. Your stent shouldn't cause metal ...

  15. Product placement in the Skyfall

    OpenAIRE

    Arustamyan, Mikayel

    2013-01-01

    The bachelor's thesis deals with product placement in the latest James Bond movie called Skyfall. The goal of this thesis is to analyse the product placement in this movie and suggest possible improvements of promotion for companies' products and brands in the next James Bond movies. In the theoretical part I write about marketing mix and marketing communication, I define the product placement and describe the history of product placement. In the practical part I analyse the effectiveness of ...

  16. Colorectal Cancer: A Personal Journey

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Colorectal Cancer Colorectal Cancer: A Personal Journey Past Issues / Summer 2016 Table ... Carmen Marc Valvo is an outspoken voice for colorectal cancer screening. Photo Courtesy of: Phil Fisch Photography Designer ...

  17. Study of the Behavior of a Bell-Shaped Colonic Self-Expandable NiTi Stent under Peristaltic Movements

    Directory of Open Access Journals (Sweden)

    Sergio Puértolas

    2013-01-01

    Full Text Available Managing bowel obstruction produced by colon cancer requires an emergency intervention to patients usually in poor conditions, and it requires creating an intestinal stoma in most cases. Regardless of that the tumor may be resectable, a two-stage surgery is mandatory. To avoid these disadvantages, endoscopic placement of self-expanding stents has been introduced more than 10 years ago, as an alternative to relieve colonic obstruction. It can be used as a bridge to elective single-stage surgery avoiding a stoma or as a definitive palliative solution in patients with irresectable tumor or poor estimated survival. Stents must be capable of exerting an adequate radial pressure on the stenosed wall, keeping in mind that stent must not move or be crushed, guaranteeing an adequate lumen when affected by peristaltic waves. A finite element simulation of bell-shaped nitinol stent functionality has been done. Catheter introduction, releasing at position, and the effect of peristaltic wave were simulated. To check the reliability of the simulation, a clinical experimentation with porcine specimens was carried out. The stent presented a good deployment and flexibility. Stent behavior was excellent, expanding from the very narrow lumen corresponding to the maximum peristaltic pressure to the complete recovery of operative lumen when the pressure disappears.

  18. Successful management of a benign anastomotic colonic stricture with self-expanding metallic stents:A case report

    Institute of Scientific and Technical Information of China (English)

    Yong-Song Guan; Long Sun; Xiao Li; Xiao-Hua Zheng

    2004-01-01

    AIM: To assess the effectiveness of and complications associated with metallic stent placement for treatment of anastomotic colonic strictures.METHODS: A 46-year-old man underging two procedures of surgery for perforation of descending colon due to a traffic accident presented with pain, abdominal distention,and inability to defecate. Single-contrast barium enema radiograph showed a severe stenosis in the region of surgical anastomosis and the patient was too weak to accept another laparotomy. Under fluoroscopic and endoscopic guidance, we placed two metallic stents in the stenosis site of the anastomosis of the patient with anastomotic colonic strictures.RESULTS: In this case of postsurgical stenosis, the first stent relieved the symptoms of obstruction, but stent migration happened on the next day so an additional stent was required to deal with the stricture and relieve the symptoms.CONCLUSION: This case confirms that metallic stenting may represent an effective treatment for anastomotic colonic strictures in the absence of other therapeutic alternatives.

  19. Metachronous colorectal carcinoma

    DEFF Research Database (Denmark)

    Bülow, Steffen; Svendsen, L B; Mellemgaard, A

    1990-01-01

    During the period 1943-67, 903 Danish patients aged less than 40 years had colorectal carcinoma. The patients were followed up for up to 41 years and during this period 44 of 501 (9 per cent) operated on for cure developed a metachronous colorectal carcinoma. The cumulative risk of a metachronous...... colorectal carcinoma was 30 per cent after up to 41 years of observation. The occurrence of a metachronous colorectal carcinoma was evenly distributed in the observation period. The cumulative survival rate after operation for a metachronous colorectal carcinoma was 41 per cent after 20 years of observation....... We propose a lifelong follow-up programme after resection of colorectal carcinoma for cure in this age group, including annual Hemoccult test and colonoscopy at 3-year intervals....

  20. A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography.

    Science.gov (United States)

    Mangold, Stefanie; De Cecco, Carlo N; Schoepf, U Joseph; Yamada, Ricardo T; Varga-Szemes, Akos; Stubenrauch, Andrew C; Caruso, Damiano; Fuller, Stephen R; Vogl, Thomas J; Nikolaou, Konstantin; Todoran, Thomas M; Wichmann, Julian L

    2016-12-01

    To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F_0.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F_0.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F_0.5 (16.9 ± 4.8; all p VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F_0.5 (90.9, 94.1, 89.3 %). 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. • The impact of noise-optimized virtual monochromatic imaging on stent visualization was assessed. • Virtual monochromatic imaging significantly improves stent lumen visualization and diagnostic confidence. • At 80 keV diagnostic performance for detection of in-stent restenosis was increased. • 80 keV virtual monochromatic images are recommended for stent evaluation of lower extremity vasculature.

  1. "Virtual" in-vivo bench test for bifurcation stenting with "StentBoost".

    Science.gov (United States)

    Agostoni, Pierfrancesco; Verheye, Stefan; Vermeersch, Paul; Cornelis, Kristoff; Van Langenhove, Glenn

    2009-04-01

    "StentBoost" is a new angiographic technique that allows improved angiographic visualization of stents deployed in coronary arteries, by enhancing the X-ray focus of the region where the stent is placed. Using this technique we were able to assess the deformation and the expansion of a stent deployed to treat a bifurcation lesion between the mid-left anterior descending (LAD) artery and a big second diagonal branch, during sequential inflations of: (1) the stent per se in the LAD, (2) the ostium of the diagonal branch through the stent struts, (3) the stent again with a non compliant balloon, and (4) both branches with the kissing balloon technique. "StentBoost" guided our clinical and angiographic decision-making process and allowed us to create a "virtual" bench test of the stent deployed at the level of the bifurcation treated.

  2. 计算机断层扫描灌注成像对颈内动脉重度狭窄支架成形术的术前指导及术后评价%Preoperative Guidance and Postoperative Evaluation in Patients with Severe Stenosis of Internal Carotid Artery before and after Stent Placement using Computer Tomography Perfusion Imaging

    Institute of Scientific and Technical Information of China (English)

    温宏峰; 陈宇; 王培福; 李继来; 杜继臣; 任艳

    2011-01-01

    目的 探讨计算机断层扫描灌注成像(computer tomography perfusion,CTP)结合数字减影血管造影(digital subtraction angiography,DSA)对颈内动脉重度狭窄支架成形术的术前适应证选择及术后血流变化评价的作用.方法:40例经DSA检查提示单侧颈内动脉重度狭窄患者,按照DSA检查结果对缺血部位代偿良好的20例患者行保宁治疗,代偿不良的20例患者行狭窄部位支架成形术,行CTP检查,比较非手术组及手术组基线和术后1年的CT相对灌注参数,并比较手术组基线、术后7d、术后1年的手术侧和健侧的绝对灌注参数.结果:手术组基线相对脑血流量 (relative cerebral blood flow,PCBF)明显较非手术组降低,相对脑血容量(relative cerebral blood volume,rCBV)升高(P分别为0.018和0.015),两组相对平均通过时间(relative mean transit time,rMTT)无差异,1年后手术组rMTT较非手术组低(P=0,012),rCBF,rCB差异无统计学意义;与健侧相比,手术组术前患侧基线平均通过时间(mean transit time,MTT)延迟、脑血流量(cerebral blood flow,CBF)减低、脑血容量(cerebral blood volume,CBV)增高,术后7d患侧MTT缩短、CBF明显增加、CBV回落,术后1年MTT,、CBF、CBV患侧与健侧相比更加接近,两组比较尽管有统计学意义(P=0.015、0.012、0.037),但三个变量总体趋势逐渐接近;手术组术前、术后7d、术后1年,不同时间点患侧与健侧绝对灌注参数变化有统计学意义(P=0.001,0.009,0.028);支架成形与时间之间有交互作用(P=0.006,0.002,0.032).结论:CTP结合DSA对颈动脉狭窄的患者合理选择手术适应证有一定指导作用.颈动脉支架成形术(carotid artery scenting,CAS)可以改善患者的脑血流状况.%Objective To evaluate the computed tomography perfusion (CTP) imaging with digital subtraction angiography (DSA) in severe carotid artery stenosis before and after stenting and clinical evaluation of hemodynamic changes.Methods Forty cases

  3. Initial study of sediment antagonism and characteristics of silver nanoparticle-coated biliary stents in an experimental animal model

    Directory of Open Access Journals (Sweden)

    Tian Y

    2016-04-01

    Full Text Available Yigeng Tian,1,* Mingfeng Xia,2,* Shuai Zhang,3 Zhen Fu,4 Qingbin Wen,2 Feng Liu,4 Zongzhen Xu,4 Tao Li,4 Hu Tian4 1Department of Physics, School of Physics and Technology, University of Jinan, Jinan, Shandong, People’s Republic of China; 2Department of Surgery, Shandong University of Traditional Chinese Medicine, Jinan, Shandong, People’s Republic of China; 3Department of General Surgery, Sixth People’s Hospital of Jinan, Jinan, Shandong, People’s Republic of China; 4Department of General Surgery, Shandong Provincial Qianfoshan Hospital, Shandong University, Jinan, Shandong, People’s Republic of China *These authors contributed equally to this work Objective: Plastic biliary stents used to relieve obstructive jaundice are frequently blocked by sediment, resulting in loss of drainage. We prepared stents coated with silver nanoparticles (AgNPs and compared their ability to resist sedimentation with Teflon stents in a beagle model of obstructive jaundice.Methods: AgNP-coated Teflon biliary stents were prepared by chemical oxidation–reduction and evaluated in an obstructive jaundice model that was produced by ligation of common bile duct (CBD; animals were randomized to two equal groups for placement of AgNP-coated or Teflon control stents. Liver function and inflammatory index were found to be similar in the two groups, and the obstruction was relieved. Stents were removed 21 days after insertion and observed by scanning and transmission electron microscopy. The AgNP coating was analyzed by energy dispersive X-ray analysis (EDXA, and the composition of sediment was assayed by Fourier-transform infrared (FTIR spectroscopy.Results: Electron microscopy revealed a black, closely adherent AgNP stent coating, with thicknesses of 1.5–6 µm. Sediment thickness and density were greater on Teflon than on AgNP-coated stents. EDXA confirmed the stability and integrity of the AgNP coating before and after in vivo animal experimentation. FTIR

  4. Inductive antenna stent: design, fabrication and characterization

    Science.gov (United States)

    Rashidi Mohammadi, Abdolreza; Ali, Mohamed Sultan Mohamed; Lappin, Derry; Schlosser, Colin; Takahata, Kenichi

    2013-02-01

    This paper describes the design, fabrication, and electromechanical characteristics of inductive stents developed for intelligent stent applications. The stents, fabricated out of 316L stainless-steel tubes using laser machining, are patterned to have zigzag loops without bridge struts, and when expanded, become a helix-like structure. Highly conductive metals such as copper and gold are coated on the stents to improve their inductive/antenna function. The Q-factor of the stent is shown to increase by a factor of 7 at 150 MHz with copper coating. The expansion of the stent from 2 to 4 mm diameter results in a 3.2× increase in the inductance, obtaining ˜1 µH at a similar frequency. The stent passivated by Parylene-C film is used to characterize its resonance in different media including saline. The copper-coated inductive stent exhibits a 2.4× radial stiffness for 1 mm strain as well as a 16× bending compliance compared with a commercial stent, each of which is potentially beneficial in preventing/mitigating stent failures such as recoil as well as enabling easier navigation through intricate blood vessels. The mechanical stiffness may be tailored by adjusting stent-wire thickness while maintaining necessary coating thickness to achieve particular mechanical requirements and high inductive performance simultaneously.

  5. Epigenetics and Colorectal Cancer

    Science.gov (United States)

    Lao, Victoria Valinluck; Grady, William M.

    2012-01-01

    Colorectal cancer is a leading cause of cancer deaths in the world. It results from an accumulation of genetic and epigenetic changes in colon epithelial cells that transforms them into adenocarcinomas. There have been major advances in our understanding of cancer epigenetics over the last decade, particularly regarding aberrant DNA methylation. Assessment of the colon cancer epigenome has revealed that virtually all colorectal cancers have aberrantly methylated genes and the average colorectal cancer methylome has hundreds to thousands of abnormally methylated genes. As with gene mutations in the cancer genome, a subset of these methylated genes, called driver genes, is presumed to play a functional role in colorectal cancer. The assessment of methylated genes in colorectal cancers has also revealed a unique molecular subgroup of colorectal cancers called CpG Island Methylator Phenotype (CIMP) cancers; these tumors have a particularly high frequency of methylated genes. The advances in our understanding of aberrant methylation in colorectal cancer has led to epigenetic alterations being developed as clinical biomarkers for diagnostic, prognostic, and therapeutic applications. Progress in the assessment of epigenetic alterations in colorectal cancer and their clinical applications has shown that these alterations will be commonly used in the near future as molecular markers to direct the prevention and treatment of colorectal cancer. PMID:22009203

  6. Port placement in thoracoscopy

    Directory of Open Access Journals (Sweden)

    KB Galketiya

    2014-03-01

    Full Text Available Background: Thoracoscopy reduces the morbidity of open thoracotomy. The placement of camera and working ports is crucial for successful completion of the procedure. Methods: A retrospective review of video assisted thoracoscopic surgeries performed during January 2011 to June 2013 at the university surgical unit, Peradeniya, Sri Lanka was done. Port placement of each surgery was identified and the adequacy of space for dissection, use of additional ports for retractors, successful, comfortable and safe completion of the surgery with regard to average operative time, mean blood loss and conversions to open surgery were noted. Results: 9 different thoracoscopic procedures were performed on 67 patients. All procedures allowed comfortable dissection, adequate space for dissection and required no additional ports for retractors except for thymectomy and excision of retrosternal goiter. Time taken was acceptable with minimum blood loss and no conversions. Conclusion: For anterior and posterior mediastinal procedures the camera port was placed in the mid and the posterior axillary lines respectively and provided a clear display of the anatomy. The thirty degree camera was preferred as it provided a wider visual field. Working ports for anterior and posterior mediastinal procedures were placed in the anterior and mid axillary line respectively. Most effective placement for working ports were found to be two intercostal spaces above and below the camera port.

  7. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion

  8. Prevention of stent thrombosis: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Reejhsinghani R

    2015-01-01

    Full Text Available Risheen Reejhsinghani, Amir S LotfiDivision of Cardiology, Baystate Medical Center, Springfield, MA, USAAbstract: Stent thrombosis is an uncommon but serious complication which carries with it significant mortality and morbidity. This review analyzes the entity of stent thrombosis from a historical and clinical perspective, and chronicles the evolution of this condition through the various generations of stent development, from bare metal to first-generation, second-generation, and third-generation drug-eluting stents. It also delineates the specific risk factors associated with stent thrombosis and comprehensively examines the literature related to each of these risks. Finally, it highlights the preventative strategies that can be garnered from the existing data, and concludes that a multifactorial approach is necessary to combat the occurrence of stent thrombosis, with higher risk groups, such as patients with ST segment elevation myocardial infarction, meriting further research.Keywords: stent thrombosis, preventative strategies, post-procedural myocardial infarction

  9. Forgotten ureteral stents: who's at risk?

    Science.gov (United States)

    Divakaruni, Naveen; Palmer, Cristina J; Tek, Peter; Bjurlin, Marc A; Gage, Mistry K; Robinson, Jed; Lombardo, Lindsay; Wille, Mark A; Hollowell, Courtney M P

    2013-08-01

    The sequelae from forgotten stents carry significant morbidity and costs. In this study, we attempt to identify potential risk factors that may make patients less likely to follow up for stent removal so that more effective prevention efforts may be directed at these persons. A single-institution retrospective analysis of 187 consecutive patients who had stents placed between January 2010 and December 2010 was performed. Chart review was conducted to see if patients had undergone stent removal beyond the intended maximal stent life (MSL). Patients who were lost to follow-up were contacted to determine if stents were overdue. Logistic regression was performed to determine risk factors. Of the 187 patients who had stents placed, 147 had the stent removed before MSL and 28 had stents removed after the MSL. Twelve patients could not be contacted and were excluded from the analysis. Within our cohort of 175 patients, 48% were males, 73% were minorities (33% Latino, 30% Black, 8% Asian, and 2% Native American), 39% did not speak English, 79% were unemployed, 73% were uninsured, and 35% were married. Among the patients with forgotten stents, 68% were male, 64% were minorities (32% Latino, 29% Black, 4% Native American, and 0% Asian), 82% were unemployed, 39% did not speak English, 93% were uninsured, and 43% were married. Multivariate regression analysis demonstrated that uninsured patients (odds ratio [OR], 6.3; 95% confidence interval [CI], 1.4-28.2; P value 0.01) and males (OR, 2.8; CI, 1.2-6.8; P=0.02) had statistically significant associations with forgotten stents. Men were 2.8 times more likely to have forgotten stents than females. Patients without health insurance were six times more likely to have forgotten stents than patients with insurance. As efforts are made to prevent forgotten stents, increased attention should be given to these higher-risk patient populations.

  10. Endourological Management of Forgotten Encrusted Ureteral Stents

    Directory of Open Access Journals (Sweden)

    Kusuma V. R. Murthy

    2010-08-01

    Full Text Available PURPOSE: To present our experience and discuss the various endourological approaches for treating forgotten encrusted ureteral stents associated with stone formation. MATERIALS AND METHODS: From July 2006 to December 2008, 14 patients (11 men and 3 women with encrusted ureteral stents were analyzed. The average indwelling time of the stent was 4.9 years (range 1 to 12. Plain-film radiography was used to evaluate encrustation, stone burden, and fragmentation of the stents. Intravenous urogram and a Tc99m diethylene triamine penta acetic-acid renogram was used to assess renal function. RESULTS: In seven patients, the entire stent was encrusted, in three patients the encrustation was confined to the ureteral and lower coil part of the stent, two patients had encrustation of the lower coil, and minimal encrustation was observed in two patients. Percutaneous nephrolithotomy was performed in 5 cases and retrograde ureteroscopy with intra-corporeal lithotripsy in 9 patients. Cystolithotripsy was used to manage the distal coil of the encrusted stent in eight patients. Simple cystoscopic removal of the stents with minimal encrustation was carried-out in two cases. Looposcopy and removal of the stent was performed in one patient with an ileal conduit and retained stent. Only one patient required open surgical removal of the stent. Thirteen out of 14 patients were rendered stone and stent free in one session. All except two stents were removed intact and stone analysis of encrustation and calcification revealed calcium oxalate and calcium phosphate in the majority of the cases. CONCLUSION: Endourological management of forgotten encrusted stents is highly successful and often avoids the need for open surgical techniques.

  11. Drug eluting biliary stents to decrease stent failure rates: Areview of the literature

    Institute of Scientific and Technical Information of China (English)

    2016-01-01

    Biliary stenting is clinically effective in relieving bothmalignant and non-malignant obstructions. However, thereare high failure rates associated with tumor ingrowth andepithelial overgrowth as well as internally from biofilmdevelopment and subsequent clogging. Within the lastdecade, the use of prophylactic drug eluting stents as ameans to reduce stent failure has been investigated. Inthis review we provide an overview of the current researchon drug eluting biliary stents. While there is limited humantrial data regarding the clinical benefit of drug elutingbiliary stents in preventing stent obstruction, recentresearch suggests promise regarding their safety andpotential efficacy.

  12. Clinical experience in coronary stenting with the Vivant Z Stent.

    Science.gov (United States)

    Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H

    2005-06-01

    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.

  13. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  14. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    OpenAIRE

    Brandt-Wunderlich Christoph; Schwerdt Christopher; Behrens Peter; Grabow Niels; Schmitz Klaus-Peter; Schmidt Wolfram

    2016-01-01

    The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen lo...

  15. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    Directory of Open Access Journals (Sweden)

    Brandt-Wunderlich Christoph

    2016-09-01

    Full Text Available The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen loss and residual diameter change dependent on the specific bending radius.

  16. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken

    2014-04-15

    A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.