Sample records for collamer lens implantation

  1. Toric implantable collamer lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Mathew Kurian Kummelil

    2013-01-01

    Full Text Available Keratoconus is a progressive non-inflammatory thinning of the cornea that induces myopia and irregular astigmatism and decreases the quality of vision due to monocular diplopia, halos, or ghost images. Keratoconus patients unfit for corneal procedures and intolerant to refractive correction by spectacles or contact lenses have been implanted toric posterior chamber phakic intraocular lenses (PC pIOLs alone or combined with other surgical procedures to correct the refractive errors associated with keratoconus as an off label procedure with special informed consent from the patients. Several reports attest to the safety and efficacy of the procedure, though the associated corneal higher order aberrations would have an impact on the final visual quality.

  2. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    Science.gov (United States)

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P lens position (r = 0.371, P lens thickness (r = -0.262, P lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P lens position less than 5.1 mm had greatly reduced vaults (P lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  3. Spontaneous Rotation of a Toric Implantable Collamer Lens

    Directory of Open Access Journals (Sweden)

    Alejandro Navas

    2010-11-01

    Full Text Available We present a case of toric implantable collamer lens (TICL spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA was 20/800 and 20/1200, respectively, with –7.75 –4.25 × 0° and –8.25 –5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 –4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months’ follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.

  4. Comparison of clear lens extraction and collamer lens implantation in high myopia

    Directory of Open Access Journals (Sweden)

    Ahmed M Emarah

    2010-05-01

    Full Text Available Ahmed M Emarah, Mostafa A El-Helw, Hazem M YassinCairo University, Cairo, EgyptAim: To compare the outcomes of clear lens extraction and collamer lens implantation in high myopia.Patients and methods: Myopic patients younger than 40 years old with more than 12 diopters of myopia or who were not fit for laser-assisted in situ keratomileusis were included. Group 1 comprised patients undergoing clear lens extraction and Group 2 patients received the Visian implantable collamer lens. Outcome and complications were evaluated.Results: Postoperative best corrected visual acuity was -0.61 ± 0.18 in Group 1 and 0.79 ± 0.16 in Group 2. In Group 1, 71.4% achieved a postoperative uncorrected visual acuity better than the preoperative best corrected visual acuity, while only 51.8% patients achieved this in Group 2. Intraocular pressure decreased by 12.55% in Group 1, and increased by 15.11% in Group 2. Corneal endothelial cell density decreased by 4.47% in Group 1 and decreased by 5.67% in Group 2. Posterior capsule opacification occurred in Group 1. In Group 2, lens opacification occurred in 11.11%, significant pigment dispersion in 3.7%, and pupillary block glaucoma in 3.7%.Conclusion: Clear lens extraction presents less of a financial load up front, and less likelihood of the need for a secondary intervention in the future. Clear lens extraction is a more viable solution in developing countries with limited financial resources.Keywords: clear lens extraction, implantable collamer lens, myopia

  5. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant

    Directory of Open Access Journals (Sweden)

    Clara Ye

    2018-06-01

    Full Text Available Purpose: We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL (Visian ICL™, Staar Inc., Monrovia, CA implant that resulted in advanced visual field loss. Observations: A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Conclusions and importance: Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss. Keywords: Phakic intraocular lens, Intraocular collamer lens, Pigment dispersion, Glaucoma

  6. Analysis on shift and rotation of intraocular lens after phakic collamer lens implantation

    Directory of Open Access Journals (Sweden)

    Yuan-Yuan Lu

    2016-05-01

    Full Text Available Recently, the incidence of myopia increases year by year. The effectiveness of refractive surgery for the correction of ametropia is widely recognized with rapid development of ophthalmic microsurgery. The laser in situ keratomileusis(LASIKhas been accepted as a regular refractive surgery technique to correct mild and moderate myopia. However, it shows inadequacy in ability to correct high refractive errors, and in patients with thin cornea and keratoconus. In 1993, Staar Surgical(A.G. Nidauintroduced a modified intraocular collamer lens(ICLfor the correction of high myopia, which emerged as a safe and effective operation for moderate or high myopia gradually. Although it has already been proved that ICL has safety and efficacy for the correction of high myopia, several studies reported dislocation and rotation of ICL after implantation, which led decreased vision and poor satisfaction. In severe cases, secondary glaucoma, anterior subcapsular cataract happened consequentially. These potential complications have drawn more and more attention by the majority of physicians and scholars. This paper aims to discuss the potential cause of shift and rotation of ICLs after implantation.

  7. Changes in stereoacuity following implantable Collamer lens implantation in patients with myopia

    Directory of Open Access Journals (Sweden)

    Sudarshan Khokhar

    2015-01-01

    Full Text Available The study evaluated the impact of implantable Collamer lens (ICL implantation on stereoacuity in myopes in a retrospective case series. Ninety-five eyes of 48 patients were recruited. Distance and near stereoacuity were measured using distance Randot stereotest and TNO test, respectively, before surgery and at 4 weeks postoperatively. Mean age of the patients was 23.67 ± 3.7 years. Mean uncorrected distance visual acuity (UDVA was 1.28 ± 0.37 logarithm of the minimum angle of resolution (logMAR (median: 1.3; range: 0.3-1.8, and median best-corrected distance visual acuity (BDVA was 0.18 logMAR (range: 0-0.6. There was a significant improvement in both UDVA and BDVA postsurgery (P < 0.001; Wilcoxon signed rank test. The overall improvement in stereopsis was observed in 15/48 (31.25% and 13/48 (27.10% subjects for near and distance, respectively, with no significant difference between the two (P = 0.82; Fisher′s exact test. Among stereoblind individuals, the odd′s ratio for near stereoacuity to improve in comparison to distance stereoacuity was 8.85 (95% confidence interval: 1.68-46.70; P = 0.01. ICL implantation for refractive correction aided stereoacuity improvement in myopes more so for near.

  8. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    Science.gov (United States)

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  9. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  10. Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator

    Directory of Open Access Journals (Sweden)

    Cari Pérez-Vives

    2014-04-01

    Full Text Available Purpose: To compare optical and visual quality of implantable collamer lens (ICL implantation and femtosecond laser in situ keratomileusis (F-LASIK for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF and point spread function (PSF were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MTF. ICL cases showed less spread out of PSF than F-LASIK cases. ICL cases showed better visual acuity values than F-LASIK cases for all pupils, contrasts, and myopic treatments (p0.05. For -6-D myopia, however, statistically significant differences in contrast sensitivities were found for both pupils for all evaluated spatial frequencies (p<0.05. Contrast sensitivities were better after ICL implantation than after F-LASIK. Conclusions: ICL implantation and F-LASIK provide good optical and visual quality, although the former provides better outcomes of MTF, PSF, visual acuity, and contrast sensitivity, especially for cases with large refractive errors and pupil sizes. These outcomes are related to the F-LASIK producing larger high-order aberrations.

  11. Four-year Follow-up of the Changes in Anterior Segment After Phakic Collamer Lens Implantation.

    Science.gov (United States)

    Lu, Yuanyuan; Yang, Na; Li, Xuedong; Kong, Jun

    2017-06-01

    To assess the changes and relationship in central vaulting, flare intensity, and crystalline lens thickness during a follow-up period of 4 years after implantable collamer lens (ICL) implantation in eyes with high myopia. Retrospective observational study. Ninety-eight eyes of 50 patients were followed up with routine measurements of central vaulting, crystalline lens thickness, endothelial cell density, and aqueous flare postoperatively. Data were analyzed by repeated-measures analysis of variance. The relationship between the annual change in crystal lens thickness after surgery and age was evaluated by Pearson correlation coefficient and linear regression. There was a continuous reduction in central vaulting and endothelial cell density as well as an increase in crystalline lens thickness in ICL eyes from 1 month onward to 5 years postoperatively (P lens thickness (r = 0.617, P lens thickness are more prominent during the first year after ICL implantation, tending to be relatively stable afterwards. The anterior inflammation during the early postoperative period synchronizes with the sharp progression of crystalline lens changes within the first year. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis.

    Science.gov (United States)

    Liu, Hong-Ting; Zhou, Zhou; Luo, Wu-Qiang; He, Wen-Jing; Agbedia, Owhofasa; Wang, Jiang-Xia; Huang, Jian-Zhong; Gao, Xin; Kong, Min; Li, Min; Li, Li

    2018-01-01

    To compare the optical quality after implantation of implantable collamer lens (ICL) and wavefront-guided laser in situ keratomileusis (WG-LASIK). The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI), the values of modulation transfer function (MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS) values (OVs) were accessed. The higher order aberrations (HOAs) data including coma, trefoil, spherical, 2 nd astigmatism and tetrafoil were also obtained. For patients with pupil size LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent ( P LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P =0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2 nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test, all P LASIK group. ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality.

  13. Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Hong-Ting Liu

    2018-04-01

    Full Text Available AIM: To compare the optical quality after implantation of implantable collamer lens (ICL and wavefront-guided laser in situ keratomileusis (WG-LASIK. METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI, the values of modulation transfer function (MTF cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS values (OVs were accessed. The higher order aberrations (HOAs data including coma, trefoil, spherical, 2nd astigmatism and tetrafoil were also obtained. For patients with pupil size <6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded. RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent (P< 0.001. After the ICL implantation, the OSI decreased slightly from 2.34±1.92 to 2.24±1.18 with no statistical significance (P=0.62. While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P=0.000. None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test

  14. Night driving simulation in a randomized prospective comparison of Visian toric implantable collamer lens and conventional PRK for moderate to high myopic astigmatism.

    Science.gov (United States)

    Schallhorn, Steven; Tanzer, David; Sanders, Donald R; Sanders, Monica; Brown, Mitch; Kaupp, Sandor E

    2010-05-01

    To compare changes in simulated night driving performance after Visian Toric Implantable Collamer Lens (TICL; STAAR Surgical) implantation and photorefractive keratectomy (PRK) for the correction of moderate to high myopic astigmatism. This prospective, randomized study consisted of 43 eyes implanted with the TICL (20 bilateral cases) and 45 eyes receiving conventional PRK (VISX Star S3 excimer laser) with mitomycin C (22 bilateral cases) for moderate to high myopia (-6.00 to -20.00 diopters[D] sphere) measured at the spectacle plane and 1.00 to 4.00 D of astigmatism. As a substudy, 27 eyes of 14 TICL patients and 41 eyes of 21 PRK patients underwent a simulated night driving test. The detection and identification distances of road signs and hazards with the Night Driving Simulator (Vision Sciences Research Corp) were measured with and without a glare source before and 6 months after each procedure. No significant difference was noted in the pre- to postoperative Night Driving Simulator in detection distances with and without the glare source between the TICL and PRK groups. The differences in identification distances without glare were significantly better for business and traffic road signs and pedestrian hazards in the TICL group relative to the PRK group whereas with glare, only the pedestrian hazards were significantly better. A clinically relevant change of Night Driving Simulator performance (>0.5 seconds change in ability to identify tasks postoperatively) was significantly better in the TICL group (with and without glare) for all identification tasks. The TICL performed better than conventional PRK in the pre- to postoperative Night Driving Simulator testing with and without a glare source present. Copyright 2010, SLACK Incorporated.

  15. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  16. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    Science.gov (United States)

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  17. Analysis of phakic before intraocular lens implantation for fundus examination

    Directory of Open Access Journals (Sweden)

    Juan Chen

    2014-10-01

    Full Text Available AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL. To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examination by three mirror from April 2011 to April 2012 in our hospital. The age, refractive diopter, the findings of Goldmann three mirror examination and the condition of retinal photocoagulation were analysed and concluded.RESULTS: A total of 34 eyes(26.8%out of all 127 eyes(64 caseswere found to have peripheral retinal pathological changes. Eight eyes(6.3%with retinal holes, 15 eyes(11.8%with retinal lattice degeneration, 5 eyes(3.9%with retina cream degeneration, 3 eyes(2.4%with retinal paving stone degeneration,2 eyes with vitreoretinal adhesion and traction,1 eye(0.8%with retinal hemorrhage. Twenty-five cases were given retinal photocoagulation and then received the ICL implantation after 3mo. The follow-up time was 1a. No retinal detachment happened.CONCLUSION:Phakic before intraocular lens implantation for fundus examination by three mirror is contributed to find the peripheral retinal pathological changes and abnormity. And make the appropriate treatment before operation for improving the security of operation, it can also give help to the postoperative follow-up of the fundus of these patients.

  18. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  19. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  20. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  1. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  2. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    Science.gov (United States)

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  3. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    Science.gov (United States)

    ... Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On Pediatric Ophthalmology ... Are Cataracts? Pediatric Cataracts Cataract Diagnosis and Treatment Cataract Surgery IOL Implants: Lens Replacement After Cataracts ...

  4. A prospective comparison of phakic collamer lenses and wavefront-optimized laser-assisted in situ keratomileusis for correction of myopia

    Directory of Open Access Journals (Sweden)

    Parkhurst GD

    2016-06-01

    Full Text Available Gregory D Parkhurst1,2 1Refractive Surgery Center, Carl R Darnall Army Medical Center, Fort Hood, 2Parkhurst NuVision, San Antonio, TX, USA Purpose: The aim of this study was to evaluate and compare night vision and low-luminance contrast sensitivity (CS in patients undergoing implantation of phakic collamer lenses or wavefront-optimized laser-assisted in situ keratomileusis (LASIK.Patients and methods: This is a nonrandomized, prospective study, in which 48 military personnel were recruited. Rabin Super Vision Test was used to compare the visual acuity and CS of Visian implantable collamer lens (ICL and LASIK groups under normal and low light conditions, using a filter for simulated vision through night vision goggles.Results: Preoperative mean spherical equivalent was –6.10 D in the ICL group and –6.04 D in the LASIK group (P=0.863. Three months postoperatively, super vision acuity (SVa, super vision acuity with (low-luminance goggles (SVaG, super vision contrast (SVc, and super vision contrast with (low luminance goggles (SVcG significantly improved in the ICL and LASIK groups (P<0.001. Mean improvement in SVaG at 3 months postoperatively was statistically significantly greater in the ICL group than in the LASIK group (mean change [logarithm of the minimum angle of resolution, LogMAR]: ICL =-0.134, LASIK =-0.085; P=0.032. Mean improvements in SVc and SVcG were also statistically significantly greater in the ICL group than in the LASIK group (SVc mean change [logarithm of the CS, LogCS]: ICL =0.356, LASIK =0.209; P=0.018 and SVcG mean change [LogCS]: ICL =0.390, LASIK =0.259; P=0.024. Mean improvement in SVa at 3 months was comparable in both groups (P=0.154.Conclusion: Simulated night vision improved with both ICL implantation and wavefront-optimized LASIK, but improvements were significantly greater with ICLs. These differences may be important in a military setting and may also affect satisfaction with civilian vision correction

  5. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  6. Phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism.

    Science.gov (United States)

    Dávila, Pedro J; Ulloa-Padilla, Jan P; Izquierdo, Natalio J

    2017-01-01

    To evaluate the benefits of phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism (OCA). The charts of 195 patients with OCA who visited a local eye clinic were reviewed. All of these patients had genetic linkage analysis to establish OCA type. Frequencies and Paired t-test analysis were determined. Of the 195 patients, nine (4.6%) underwent clear cornea phacoemulsification with intraocular lens implantation. Seven of the nine patients with OCA had the Hermansky-Pudlak (HPS) type 1; two had OCA type 1. Pre-operative BCVA of all eyes ranged from 1.0 to 2.3 logMAR with a mean of 1.42 logMAR and a standard deviation of 0.41 logMAR. Post-operative BCVA of all eyes ranged from 1.0 to 1.30 logMAR with a mean of 1.04 logMAR and a standard deviation of 0.10 logMAR. BCVA improved after phacoemulsification surgery and intraocular lens implantation (p = 0.002). Pre-operative astigmatism of all eyes ranged from +0.50 to +5.75 with a mean of +2.25 and a standard deviation of +2.40. Post-operative astigmatism of all eyes ranged from +0.50 to +2.00 with a mean of +1.23 and a standard deviation of +0.42. Astigmatism improved after phacoemulsification surgery and intraocular lens implantation (p = 0.05). Nine patients with OCA who underwent phacoemulsification and intraocular lens implant experienced improved visual acuity and reduced astigmatism post-operatively. These results suggest cataract surgery may improve vision and refractive errors, and thus quality of life, in patients with albinism.

  7. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Sutureless Intrascleral Fixated Intraocular Lens Implantation.

    Science.gov (United States)

    Karadag, Remzi; Celik, Haci Ugur; Bayramlar, Huseyin; Rapuano, Christopher J

    2016-08-01

    To review sutureless intrascleral intraocular lens (IOL) fixation methods. Review of published literature. Sutureless intrascleral IOL fixation methods are newer and have been developed to eliminate the suture-related complications of sutured scleral fixation methods such as suture-induced inflammation or infection and IOL dislocation or subluxation due to suture degradation or suture breakage. Sutureless intrascleral fixation methods aim for intrascleral haptic fixation to achieve stability of the IOL. Various methods of sutureless scleral fixation have been described. Using a needle, a blade, or a trochar, sclerostomies are created in all techniques for intraocular access. Some surgeons prefer to create scleral tunnels, whereas others use scleral flaps for scleral fixation of haptics. The stability of IOLs is attained by the scar tissue formed around the haptics. Short-term results of these new methods are acceptable; studies including more cases with longer follow-up are needed to determine their long-term success. [J Cataract Refract Surg. 2016;32(9):586-597.]. Copyright 2016, SLACK Incorporated.

  9. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    Science.gov (United States)

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  10. [Laser magnetotherapy after cataract extraction with implantation of intraocular lens].

    Science.gov (United States)

    Maksimov, V Iu; Zakharova, N V; Maksimova, I S; Golushkov, G A; Evseev, S Iu

    2002-01-01

    Effects of low-intensive laser and alternating magnetic field on the course of the postoperative period were studied in patients with exudative reaction after extracapsular cataract extraction with implantation of intraocular lens (IOL). The results are analyzed for 148 eyes with early exudative reaction after IOL implantation (136 patients aged 42-75 years). The patients were observed for up to 6 months. The treatment efficiency was evaluated by the clinical picture of inflammatory reaction, visual acuity, and results of biochemical analysis of the lacrimal fluid (the ratio of lipid peroxidation products to antioxidants in cell membrane). The course of the postoperative period was more benign and recovery sooner in patients of the main group in comparison with the control.

  11. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  12. [Multifocal phakic intraocular lens implant to correct presbyopia].

    Science.gov (United States)

    Baikoff, G; Matach, G; Fontaine, A; Ferraz, C; Spera, C

    2005-03-01

    Presbyopic surgery is considered as the new frontier in refractive surgery. Different solutions are proposed: myopization of one eye, insertion of an accommodative crystalline lens, scleral surgery, the effects of which are still unknown, and finally multifocal phakic implants. We therefore decided to undertake a prospective study under the Huriet law to determine its efficacy and specify the conditions required for an anterior chamber multifocal phakic implant. Fifty-five eyes of 33 patients received an anterior chamber foldable multifocal phakic implant. Twenty-one females and 12 males underwent surgery. Initial refraction was between -5D and +5D. The implant's single addition was +2.50. Recuperating a distant uncorrected visual acuity of 0.6 or better and near uncorrected vision of Parinaud 3 or better can be considered a very good postoperative result. Average follow-up was 42.6+/-18 weeks. Mean postoperative refraction was -0.12+/-0.51 D. Mean postoperative uncorrected visual acuity was 0.78+/-0.20. Postoperative uncorrected visual acuity was Parinaud 2.3+/-0.6. Eighty-four percent of eyes operated on recuperated 0.6 or better without correction and Parinaud 3 or better without correction. Lenses in four eyes were explanted for different reasons, essentially optical, and no severe anatomical complications were observed. Placing an anterior chamber multifocal phakic implant to correct presbyopia is an effective technique with good predictability and has the advantage of being reversible in case of intolerance, optical parasite effects or undesired complications. Considering the particularity of this surgery, it is imperative to respect very strict inclusion criteria: anterior chamber depth equal to or above 3.1 mm, open angle, endothelial cell count equal to or above 2000 cells/mm2, absence of an incipient cataract or the slightest evidence of macular alteration.

  13. Retreatments after multifocal intraocular lens implantation: an analysis

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-03-01

    Full Text Available Kjell Gunnar Gundersen,1 Sarah Makari,2 Steffen Ostenstad,1 Rick Potvin2 1Ifocus Eye Clinic, Haugesund, Norway; 2Science in Vision, Akron, NY, USA Purpose: To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL implantation and to evaluate the methods and clinical outcomes of retreatment.Patients and methods: A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients.Results: The multifocal retreatment rate was 10.8% (45/416 eyes. The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01. The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152 and bilateral trifocal (6.9%, 14/202 IOLs, was not statistically significantly different (P=0.12. In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time.Conclusion: Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. Keywords: piggyback IOL, Sulcoflex, toric, STAAR, symptoms, astigmatism

  14. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05). Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division

  15. Severe pigment dispersion after iris-claw phakic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    2017-01-01

    Full Text Available A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  16. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    Science.gov (United States)

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  17. Clinical study of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes

    Directory of Open Access Journals (Sweden)

    Ru-Fa Meng

    2015-07-01

    Full Text Available AIM: To investigate the operation methods and clinical effects of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes.METHODS: During January 2012 to January 2014, foldable intraocular lens was implanted on 47 cases following lens-vitrectomy in residual capsular with traumatic eyes 3~6mo. Follow-up period was 6~12mo, averaged(8.21±2.63mo. RESULTS:All of 47 eyes had successful operation at one time, and position deviation was not appeared. The naked vision of the last postoperative follow-up was(0.44±0.19. Compared with best corrected visual acuity(0.41±0.23, and There was no significant difference between visual acuity of preoperative and last follow-up period(t=0.879, P=0.342. No severe complication was found. CONCLUSION: Secondary implantation of foldable intraocular lens is a safe and reliable method for correcting ametropia after lens-vitrectomy in residual capsular with traumatic eyes.

  18. Results of Posterior Chamber Lens Implantation for Correction of Myopia

    Directory of Open Access Journals (Sweden)

    Pınar Sorgun Evcili

    2012-10-01

    Full Text Available Pur po se: To evaluate the results of posterior chamber phakic intraocular lens implantation in myopic patients. Ma te ri al and Met hod: Posterior chamber phakic intraocular lens (STAAR ICL implantation was performed in 58 eyes of 33 patients with mean spherical equivalent of -13.12±5.31 diopters (D (-2.5 - -24.75 D between August 2007 and October 2010 at Dr. Lütfi Kırdar Kartal Training and Research Hospital, Second Eye Clinic. The mean age of the patients was 32.84 ± 9.95 years (18-55 years - 24 (72.7% were male and 9 (27.3% were female. The study was designed as prospective case series. The patients were evaluated regarding visual acuity, refraction, endothelial cell count, and complications in postoperative period. Re sults: The mean follow-up time was 21.5±4.9 (12-24 months months. The mean spherical equivalent was -1.29±1.53 D (-5.6 D - +2.60 D at the last postoperative follow-up visit. Visual acuity was better or equal to preoperative best-corrected value in 42 (72.4% of eyes at the last follow-up visit postoperatively. Mean spherical equivalent was regressed to -1.13±1.59D at 1-month and -1.39±1.53D at 24-month postoperative follow-up visit. Pupillary-block glaucoma in 1 eye (1.7%, anterior subcapsular opacification not affecting the vision in 4 eyes, and retinal detachment in 1 eye were detected at follow-up visits. Dis cus si on: ICL implantation was observed to be an effective and safe method for correction of myopia in two-year follow-up. As possible retinal complications may develop, the patients must be followed carefully during the preoperative and postoperative period. (Turk J Ophthalmol 2012; 42: 349-54

  19. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    OpenAIRE

    Liang-Nan Sun; Bai-Jun Li; Yuan-Fei Zhu; Xin-Hua Liu

    2017-01-01

    AIM: To evaluate the clinical results of capsular tension ring(CTR)implantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyes)with congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOL)implantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperati...

  20. [Pigment dispersion and Artisan implants: crystalline lens rise as a safety criterion].

    Science.gov (United States)

    Baikoff, G; Bourgeon, G; Jodai, H Jitsuo; Fontaine, A; Vieira Lellis, F; Trinquet, L

    2005-06-01

    To validate the theoretical notion of a crystalline lens rise as a safety criterion for ARTISAN implants in order to prevent the development of pigment dispersion in the implanted eye. Crystalline lens rise is defined by the distance between the crystalline lens's anterior pole and the horizontal plane joining the opposite iridocorneal recesses. We analyzed the biometric measurements of 87 eyes with an Artisan implant. A comparative analysis of the crystalline lens rise was carried out on the nine eyes having developed pigment dispersion and 78 eyes with no problems. Among the modern anterior segment imaging devices (Artemis, Scheimpflug photography, optical coherence tomography, radiology exploration, magnetic resonance imaging, TDM), an anterior chamber optical coherence tomography (AC-OCT) prototype was used. This working hypothesis was confirmed by this study: the crystalline lens rise must be considered as a new safety criterion for implanting Artisan phakic lenses. Indeed, the higher the crystalline lens's rise, the greater the risk of developing pigment dispersion in the pupil area. This complication is more frequent in hyperopes than in myopes. We can consider that there is little or no risk of pigment dispersion if the rise is below 600 microm; however, at 600 microm or greater, there is a 67% rate of pupillary pigment dispersion. In certain cases, when the implant was loosely fixed, there was no traction on the iris root. This is a complication that can be avoided or delayed. The crystalline lens rise must be part of new safety criteria to be taken into consideration when inserting an Artisan implant. This notion must also be applied to other types of phakic implants. The distance remaining between the crystalline lens rise and a 600-micromm theoretical safety level allows one to calculate a safety time interval.

  1. Accidental injections of dexamethasone intravitreal implant (Ozurdex) into the crystalline lens.

    Science.gov (United States)

    Coca-Robinot, Javier; Casco-Silva, Bruno; Armadá-Maresca, Felix; García-Martínez, Jesús

    2014-01-01

    To describe the side effects and management after inadvertent injection of a dexamethasone implant (Ozurdex) into the crystalline lens. Two case reports. Two patients with macular edema due to unilateral retinal vein occlusion were scheduled for an intravitreal injection of Ozurdex. During the procedure, the implant was accidentally injected into the crystalline lens. Both patients developed cataracts during the course of several weeks and in both there was an intraocular pressure (IOP) increase, which required treatment with topical hypotensives. Macular edema improved only slightly. Cataract surgery with uneventful removal of the implant was performed 3 (case 1) and 6 months (case 2) after the injection. After inadvertent injection of Ozurdex into the crystalline lens, cataract surgery with removal of the implant should be performed as soon as possible in order to avoid IOP increase and so that the underlying condition may be treated adequately.

  2. Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Ong, Hon Shing; Evans, Jennifer R; Allan, Bruce D S

    2014-05-01

    Following cataract surgery and intraocular lens (IOL) implantation, loss of accommodation or postoperative presbyopia occurs and remains a challenge. Standard monofocal IOLs correct only distance vision; patients require spectacles for near vision. Accommodative IOLs have been designed to overcome loss of accommodation after cataract surgery. To define (a) the extent to which accommodative IOLs improve unaided near visual function, in comparison with monofocal IOLs; (b) the extent of compromise to unaided distance visual acuity; c) whether a higher rate of additional complications is associated the use of accommodative IOLs. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE in-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily Update, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 October 2013. We include randomised controlled trials (RCTs) which compared implantation of accommodative IOLs to implantation of monofocal IOLs in cataract surgery. Two authors independently screened search results, assessed risk of bias and extracted data. All included trials used the 1CU accommodative IOL (HumanOptics, Erlangen, Germany) for their intervention group. One trial had an additional arm with the AT-45 Crystalens accommodative IOL (Eyeonics Vision). We performed a separate analysis comparing 1CU and AT-45 IOL. We included four RCTs, including 229 participants (256 eyes

  3. Efficacy on chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Xiao-Ning Peng

    2014-04-01

    Full Text Available AIM: To study the clinical effects of chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation.METHODS:A total of 75 cases(80 eyes, in which loop-pad and chop knife were performed to chop nucleus before implanting intraocular lens. Visual acuity, postoperative astigmatism degree, intraoperative and postoperative complications were observed. The post-operative follow-up periods ranged from 3 to 12mo.RESULTS: The visual acuity was 0.3-0.5 in 37 eyes and 0.6 or better in 21 eyes at 1d, while was respectively in 43 eyes and in 26 eyes at 1mo. Compared with preoperative astigmatism(0.85±0.29D, there were significant difference at postoperative 1wk(1.75±0.55D(PP>0.05. Intraoperative posterior capsule rupture occurred in 4 eyes, which implantation was successful in 1 eye and 3 eyes was managed viaciliary sulcus. Two eyes had dermatoglyphic pattern edema in corneal endothelium which recovered after about 3d. Two eyes had local patchy opacities which recovered in 2wk. Two eyes had transient high intraocular pressure.CONCLUSION: The surgery is efficient, low cost, easy process and less complications, it is worth to be popularized.

  4. Clinical assessment of diclofenac sodium eye drops in toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yan Luo

    2013-05-01

    Full Text Available AIM:To evaluate the application of diclofenac sodium eye drops in toric intraocular lens implantation. METHODS: From January 2011 to February 2012, 38 eyes of 37 patients, who underwent toric intraocular lens implantation in this hospital, were randomly divided into diclofenac sodium eye drops group(trial groupand control group. Patient's degree of cooperation during surgery and inflammation postoperation after 1 day, 3,7, days, 1 month and 3 months were evaluated. RESULTS: Patient's degree of cooperation during surgery in the trial group(1.53±0.62was significantly better than in the control group(2.40±0.88, P<0.05. Inflammation reaction was gentle in the trial group 1 day postoperatively. CONCLUSION: Diclofenac sodium eye drops used during toric intraocular lens implantation can obviously alleviate eye irritation, and increase the cooperation of patients.

  5. Black diaphragm intraocular lens implantation and penetrating keratoplasty in aphakic eyes with traumatic aniridia

    Directory of Open Access Journals (Sweden)

    Xiao-Guang Dong

    2013-04-01

    Full Text Available AIM: To evaluate the long-term outcome of implantation of black diaphragm intraocular (BDI lens combined with penetrating keratoplasty (PKP for managing aphakic eyes with traumatic aniridia and corneal damage. METHODS: Six aphakic eyes of six patients with traumatic aniridia and corneal damage had BDI lens implantation at Qingdao Eye Hospital, Shandong Eye Institute from June 2008 to November 2011. Medical records of the patients were reviewed. Three patients received PKP and after 12-18months were implanted with BDI lens. The other three patients completed PKP and BDI lens implantation at the same time. The corrected visual acuity, intraocular pressure and number of corneal endothelial cells were monitored. RESULTS: The patients were followed up for an average of 24.3±12.1months (range 14-48 months. All BDI lenses were located well. The best corrected visual acuity got improved in 5 patients (0.1-1.0 and decreased in 1 patient from 0.4 to 0.2. Three patients had normal intraocular pressure (IOP after implantation. Two patients required antiglaucoma medications to control IOP within the normal range and 1 patient implanted Ahmed glaucoma valve to control IOP. The corneal grafts kept transparent in all eyes and the corneal endothelial counting >1 000/mm2, although two patients experienced acute graft rejection and loss more than 30% corneal endothelial cells. CONCLUSION: Implantation of BDI lens combined with PKP is an effective option for managing aphakic eyes with traumatic aniridia and corneal damage. Although the results in our study are encouraging, additional studies of the long-term safety and efficacy are required. A larger study population and longer follow-up may be beneficial.

  6. Cell adhesion of F{sup +} ion implantation of intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.J. E-mail: dejunli@hotmail.com; Cui, F.Z.; Gu, H.Q

    1999-04-01

    The cell adhesion of ion implanted polymethylmethacrylate (PMMA) intraocular lens was studied using cultured cells in vitro. F{sup +} ion implantation was performed at the energies of 40, 60, 80, 100 keV with the fluences ranging from 5x10{sup 13} to 1x10{sup 15} ions/cm{sup 2} at room temperature. The cell adhesion tests gave interesting results that the number of the neutral granulocytes and the macrophages adhering on surface were reduced significantly after ion implantation. The optimal fluence was about 4x10{sup 14} ions/cm{sup 2}. The hydrophobicity imparted to the lens surface was also enhanced. The results of X-ray photoelectron spectroscopy analysis indicated that ion implantation resulted in the cleavage of some pendant groups, the oxidation of the surface, and the formation of some new chemical bonds, which was probably the main reason for the cell adhesion change.

  7. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  8. Clinical observation of capsular tension ring implantation in congenital lens subluxation treating by phacoemulsification

    Directory of Open Access Journals (Sweden)

    Liang-Nan Sun

    2017-07-01

    Full Text Available AIM: To evaluate the clinical results of capsular tension ring(CTRimplantation in phacoemulsification for eyes with congenital lens subluxation. METHODS: This study comprised 18 patients(31 eyeswith congenital ectopia lentis. All patients received phacoemulsification with CTR and intraocular lens(IOLimplantation. Visual acuity before and after surgery were examined. IOL decentration were measured with Image-Pro Plus image processing software. The complications were also recorded preoperatively and postoperatively. RESULTS: Uncorrected vision of all eyes increased after surgery, and all cases had different degree of IOL decentration after surgery. Two eyes received CTR scleral fixation 3mo after surgery because the IOL decentration aggravated during the follow-up period. CONCLUSION: Phacoemulsification with CTR and IOL implantation is effective and safe for congenital lens subluxation. The implantation of CTR increase the stability of the capsular bag, improve the safety of surgery, and maintain the right position of IOL. CTR scleral fixation is a effective supplement for progressive cases.

  9. Visual outcomes after lensectomy and iris claw artisan intraocular lens implantation in patients with Marfan syndrome.

    Science.gov (United States)

    Rabie, Hossein Mohammad; Malekifar, Parviz; Javadi, Mohammad Ali; Roshandel, Danial; Esfandiari, Hamed

    2017-08-01

    To review our experience with crystalline lens extraction and iris claw Artisan IOL implantation in patients with lens subluxation secondary to Marfan syndrome. A retrospective analysis of 12 eyes of 9 patients with lens subluxation due to Marfan syndrome who underwent crystalline lens removal and Artisan IOL (Ophtec, Groningen, Netherlands) implantation. A questionnaire of pre- and post-operative data, including demographics, pre- and postoperative comorbidities and complications was completed. Patients were evaluated for visual outcome and occurrence of complications. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalents (SE) were compared before and after lens extraction and IOL insertion. The mean age of the participants was 30.03 ± 15.02 years, and mean post-operative follow-up time was 44.5 ± 16.4 months. Mean BCVA also showed a significant improvement from 0.5 ± 0.3 at the baseline to 0.2 ± 0.2 post-operatively (P = 0.006). SE changed significantly from -11.38 ± 1.99 preoperatively to -0.45 ± 1.65 post-operatively (P = 0.003). All eyes had the IOL implanted at desired position. Post-operative complications were retinal detachment in one case and IOL dislocation in another patient. No other complication such as ocular hypertension, angle abnormalities, clinical cystoids macular edema, and corneal decompensation was observed during the follow-up period. Artisan IOL implantation after lens extraction appears to be an attractive alternative for optical correction in cases of Marfan syndrome with ectopia lentis. It confers a significant improvement in visual acuity with reasonable risk profile.

  10. Intra-ocular lens implantation after vitreous loss.

    Directory of Open Access Journals (Sweden)

    Shah N

    1991-10-01

    Full Text Available Vitreous loss is a dreaded complication of cataract surgery, especially so with IOL implant which then may have to be abandoned. Thirty three cases of IOL implants, either anterior chamber or posterior chamber, after vitreous loss done in the past 3 years were studied. Of these, 18 (55% had a final visual acuity of 6/18 or better and none was worse than 6/60. The postoperative complications and findings and a review of literature are discussed.

  11. Temporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.

    Science.gov (United States)

    Hwang, Sungsoon; Lim, Dong Hui; Lee, Soomin; Choi, Daye Diana; Chung, Eui-Sang; Chung, Tae-Young

    2018-04-01

    To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL implantation within the first 3 years of life from 1999 to 2013 at Samsung Medical Center were reviewed. Twenty-eight eyes from 18 patients underwent single IOL implantation (monopseudophakia group), and 32 eyes of 20 patients underwent temporary piggyback IOL implantation in congenital cataract surgery (polypseudophakia group). The mean age at initial cataract surgery was 15.8 months in the monopseudophakia group and 11.1 months in the polypseudophakia group (P = 0.144). The average follow-up duration was 133 months in the monopseudophakia group and 120 months in the polypseudophakia group (P = 0.391). The best-corrected visual acuity at the last visit was 0.36 logMAR in the monopseudophakia group and 0.55 logMAR in the polypseudophakia group (P = 0.044). Four (14%) and 14 (44%) reoperations for complications within the anterior segment were performed in the monopseudophakia group and polypseudophakia group, respectively (P = 0.042). Four cases (14.3%) in the monopseudophakia group and 13 cases (40.6%) in the polypseudophakia group had a glaucoma-related adverse event (P = 0.086). Compared with primary single IOL implantation in congenital cataract, temporary piggyback IOL implantation produced worse visual acuity, higher reoperation rate, and higher risk of secondary glaucoma. Temporary piggyback IOL implantation does not have benefit in congenital cataract.

  12. Micro sized implantable ball lens-based fiber optic probe design

    Science.gov (United States)

    Cha, Jaepyeong; Kang, Jin U.

    2014-02-01

    A micro sized implantable ball lens-based fiber optic probe design is described for continuous monitoring of brain activity in freely behaving mice. A prototype uses a 500-micron ball lens and a highly flexible 350-micron-diameter fiber bundle, which are enclosed by a 21G stainless steel sheath. Several types and thickness of brain tissue, consisting of fluorescent probes such as GFP, GCaMP3 calcium indicator, are used to evaluate the performance of the imaging probe. Measured working distance is approximately 400-μm, but is long enough to detect neural activities from cortical and cerebellar tissues of mice brain.

  13. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    Science.gov (United States)

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  14. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  15. Early versus late traumatic cataract surgery and intraocular lens implantation.

    Science.gov (United States)

    Tabatabaei, S A; Rajabi, M B; Tabatabaei, S M; Soleimani, M; Rahimi, F; Yaseri, M

    2017-08-01

    PurposeTo determine the proper time for traumatic cataract surgery after open globe injuries.SettingFarabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.DesignRandomized clinical trial.Patients and methodsIn a randomized clinical trial, 30 eyes with traumatic cataract after open globe injury with IOL implantation underwent early (in the first week after the trauma) and 30 eyes underwent late cataract surgery (from the first to second month after the trauma). We excluded patients who were under 12-year-old. All patients were visited at 1 week, 4 weeks, 12 weeks, and 6 months after surgery. In each visit, patients were examined regarding visual acuity, intraocular pressure (IOP), anterior chamber inflammation, IOL position, and posterior synechiae. In addition, posterior segment evaluation and fundoscopy were performed. Intraoperative complication including posterior capsular rupture, anterior vitrectomy, and zonulysis as well as the site of IOL implantation were documented and post-operative complications including raised IOP, anterior chamber inflammation, visual axis opacity, posterior synechiae, subluxation of IOL, and IOL pigment deposition were listed.ResultsBest-corrected visual acuity 6 months after surgery was not different between the two groups. Also in early cataract surgery group, the rate of posterior capsular rupture was not significantly higher than the late surgery group (P=0.069). On the other hand, zonulysis was significantly higher in the late procedure group (P=0.039). Other complications including anterior vitrectomy, raised IOP, anterior chamber inflammation, visual axis opacity, posterior synechiae, subluxation of IOL, and IOL pigment deposition were not different in the two groups.ConclusionsEarly and late traumatic cataract surgery and IOL implantation after open globe injuries, have no significant difference regarding the post-surgical BCVA and prominent intraoperative and post-operative complications.

  16. Effects of phacoemulsification combined with intraocular lens implantation on ocular surface

    Directory of Open Access Journals (Sweden)

    Ming Li

    2013-10-01

    Full Text Available AIM: To explore the changes of ocular surface after phacoemulsification combined with intraocular lens implantation. METHODS: Totally 78 cases of 78 eyes with age-related cataract were collected from August 2011 to October 2012, and they underwent corneal incision phacoemulsification combined with intraocular lens implantation. The score of dry eye symptoms; tear breakup time(BUT; Schirmer Ⅰ test(SⅠtand corneal fluorescein staining were observed and recorded in 3 days before, 1 day, 1 week, 1 month, 3 and 6 months after surgery respectively. The results were analyzed statistically. RESULTS: All the subjects complained of dry eye within 1 week after surgery. Compared with 3 days before the surgery, the corneal fluorescein staining increased and the amount of tear secretion reduced statistically significant in 1 day, 1 week and 1 month(PPP>0.05, and lasted to 3 months later. CONCLUSION: Phacoemulsification combined with intraocular lens implantation has obvious effect on the ocular surface to some extent. Preventions and treatment should be taken clinically.

  17. Simultaneous and sequential implantation of intacs and verisyse phakic intraocular lens for refractive improvement in keratectasia.

    Science.gov (United States)

    Moshirfar, Majid; Fenzl, Carlton R; Meyer, Jay J; Neuffer, Marcus C; Espandar, Ladan; Mifflin, Mark D

    2011-02-01

    To evaluate the safety, efficacy, and visual outcomes of simultaneous and sequential implantation of Intacs (Addition Technology, Inc, Sunnyvale, CA) and Verisyse phakic intraocular lens (AMO, Santa Ana, CA) in selected cases of ectatic corneal disease. John A. Moran Eye Center, University of Utah, UT. Prospective data were collected from 19 eyes of 12 patients (5 eyes, post-laser in situ keratomileusis ectasia and 14 eyes, keratoconus). Intacs segments were implanted followed by insertion of a phakic Verisyse lens at the same session (12 eyes) in the simultaneous group or several months later (7 eyes) in the sequential group. The uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest refraction were recorded at each visit. No intraoperative or postoperative complications were observed. At the last follow-up (19 ± 6 months), in the simultaneous group, mean spherical error was -0.79 ± 1.0 diopter (D) (range, -2.0 to +1.50 D) and cylindrical error +2.06 ± 1.21 D (range, +0.5 to +3.75 D). In the sequential group, at the last follow-up, at 36 ± 21 months, the mean spherical error was -1.64 ± 1.31 D (range, -3.25 to +1.0 D) and cylindrical error +2.07 ± 1.03 D (range, +0.75 to +3.25 D). There were no significant differences in mean uncorrected visual acuity or BSCVA between the 2 groups preoperatively or postoperatively. No eye lost lines of preoperative BSCVA. Combined insertion of Intacs and Verisyse was safe and effective in all cases. The outcomes of the simultaneous implantation of the Intacs and Verisyse lens in 1 surgery were similar to the results achieved with sequential implantation using 2 surgeries.

  18. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  19. Resultados de implante de lente intraocular en niños Results of intraocular lens implantation in children

    Directory of Open Access Journals (Sweden)

    Nashelly I. Mejía Cruz

    2007-12-01

    Full Text Available En este estudio se describen los resultados obtenidos del implante de lente intraocular en niños, quienes acudieron al servicio de Oftalmología Pediátrica de Instituto Cubano de oftalmología “Ramón Pando Ferrer” con el diagnóstico de catarata de diversas etiologías, en período comprendido entre abril del 2002 al 2005 cuyo seguimiento fue durante un año. En nuestro universo de estudio se determinan algunos parámetros como la edad del paciente, etiología de las cataratas, agudeza visual, defecto refractivo preoperatorio y posoperatorio. Se identificó el poder dióptrico del lente intraocular más frecuente, la presencia de complicaciones durante la cirugía y después de esta. Se evaluaron finalmente, los pacientes que requerían de tratamiento adicional como la capsulotomía con láser o membranectomía quirúrgica. El implante del lente intraocular a temprana edad se relacionó con buenos resultados quirúrgicos: mejoría de la agudeza visual corregida, presentándose el astigmatismo como el error refractivo más frecuente. La complicación transoperatorio y postoperatoria más frecuente fue la membrana inflamatoria, mientras que la complicación posoperatoria más frecuente fue la opacidad de la cápsula posterior.This paper described the results of the intraocular lens implantation performed in children, who had been seen at the Pediatric Ophthalmologic Service of " Ramon Pando Ferrer " Cuban Institute of Ophthalmology and had been diagnosed as having cataract of various etiologies, from April 2002 to April 2005. They were all followed-up for a year. Some parameters like the patient’s age, the etiology of cataract, visual acuity, pre-operative and post-operative refractive defect were considered in our study. The dioptric power of the most common intraocular lens and the most frequent complications during and after surgery were identified. The patients requiring additional treatment such as laser capsulotomy and surgical

  20. Comparison on the visual quality after different multifocal lens implantation in cataract patients

    Directory of Open Access Journals (Sweden)

    Si-Meng Qu

    2018-02-01

    Full Text Available AIM: To compare the visual quality after different multifocal lens(MIOLimplantation in cataract patients. METHODS:Totally 78 cases(78 eyesof cataract patients who receiving phacoemulsification and implantation of different MIOL were enrolled from February 2016 to June 2017 in our hospital. According to the different type of implanted MIOL, the 78 cases(78 eyeswere divided Group A, B and C, each group was 26 cases(26 eyes. Patients in the Group A were implanted regional refraction MIOL SBL-3; patients in the Group B implanted step progressive diffraction MIOL SN6AD1; patients in the Group C implanted all-optical plane diffraction MIOL Tecnis ZMB00. The visual acuity, contrast sensitivity, defocus testing, contrast visual acuity and satisfaction of visual quality were compared in 3 groups at postoperative 3mo. RESULTS: There was no statistically significant difference in postoperative adverse reactions between the three groups(P>0.05. There was statistical difference in uncorrected intermediate visual acuity, uncorrected near visual acuity, distance-corrected intermediate visual acuity and distance-corrected near visual acuity in 3 groups(PPPPPPPPPCONCLUSION:The region refraction MIOL SBL-3 not only could provide better distant, intermediate and near visual acuity, but also could provide better contrast sensitivity and contrast visual acuity, thereby greatly increase visual quality satisfaction.

  1. Clinical research of phacoemulsification with posterior chamber intraocular lens implantation for glaucoma with different goniosynechia ranges

    Directory of Open Access Journals (Sweden)

    Qing-Yu Li

    2016-02-01

    Full Text Available AIM:To study the effect of phacoemulsification with posterior chamber intraocular lens implantation to treat glaucoma with different angle-closure range, which may provide a better way to treat the angle-closure glaucoma.METHODS:There were 47 cases(54 eyeswith angle-closure glaucoma, and all of them underwent phacoemulsification and posterior chamber intraocular lens implantation. According to the range of goniosynechia, these patients were divided into three groups:the eyes with the range of goniosynechia≤1/2 were group A(13 eyes; the eyes with 1/23/4 were group C(23 eyes. We observed the status of anterior chamber angle and the intraocular pressure(IOPof the three groups at 2wk after operations. RESULTS:Compared to the preoperative condition, the IOP of the three groups at 2wk after operations decreased significantly. The IOP reductions of group B and C were more significant than that of group A, and the differences were significant(PPP3/4 appeared in group B; in group C, there were 5 eyes with goniosynechia>3/4, 1 eye with disappeared anterior chamber, 3 eyes with corneal edema, 1 eye with choroidal hemorrhage. The differences of postoperative complication rate among the three groups was statistically significant(PPCONCLUSION:For patients with angle closure glaucoma who have mild to moderate goniosynechia, phacoemulsification with posterior chamber intraocular lens implantation is an effective way. After operations, their closed anterior angle reopened. But to the patients with severe adhesions, there are more complications after operations, especially the glaucoma may reoccur.

  2. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens.

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. The mean follow-up was 23 months (range: 6-48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context of a surgery usually indicated in

  3. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  4. Visual performance after the implantation of a new trifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Vryghem JC

    2013-10-01

    Full Text Available Jérôme C Vryghem,1,2 Steven Heireman1,21Brussels Eye Doctors, Brussels, Belgium; 2Clinique Saint-Jean, Brussels, BelgiumPurpose: To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens.Methods: A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients.Results: The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09. LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced.Conclusion: The introduction of a third focus in diffractive multifocal

  5. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  6. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  7. Implantation of iris-claw Artisan intraocular lens for aphakia in Fuchs′ heterochromic iridocyclitis

    Directory of Open Access Journals (Sweden)

    Ahmad Kheirkhah

    2014-01-01

    Full Text Available Implantation of iris-claw Artisan intraocular lens (IOL is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs′ heterochromic iridocyclitis (FHI due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphakia with no capsular support due to a previous complicated cataract surgery. Enclavation was easily performed and no intraoperative complication was noted. Postoperative course was uneventful with no significant anterior chamber inflammation during 12 months of follow-up. Although there were few deposits on the IOL surface, the patient achieved a best-corrected visual acuity of 20/20 without developing glaucoma or other complications. Therefore, Artisan IOL may be considered for correction of aphakia in patients with FHI. However, studies on large number of patients are required to evaluate safety of the procedure.

  8. [Hyperopic Laser-in-situ-Keratomileusis after trifocal intraocular lens implantation : Aberration-free femto-Laser-in-situ-Keratomileusis treatment after implantation of a diffractive, multifocal, toric intraocular lens-case analysis].

    Science.gov (United States)

    Hemkeppler, E; Böhm, M; Kohnen, T

    2018-05-29

    A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.

  9. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  10. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Vilar C

    2017-08-01

    Full Text Available César Vilar,1,2 Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 Klayny Rafaella Pereira Magalhães,2 Patrick Frensel de Moraes Tzelikis,1,2 Mario Augusto Pereira Dias Chaves,2,4 Antônio Francisco Pimenta Motta,2,3 Pedro Carlos Carricondo,1–3 Milton Ruiz Alves,3 Walton Nosé5 1Cataract Division, Brasília Ophthalmologic Hospital (HOB, Brasília-DF, Brazil; 2Renato Ambrosio Ophthalmologic Research Center (CEORA, 3Ophthalmology Department, São Paulo University – USP, São Paulo-SP, Brazil; 4Cataract Division, ProVisão, João Pessoa-PB, Brazil; 5Ophthalmology Department, Paulista Medical School – UNIFESP, São Paulo-SP, Brazil Purpose: To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye.Methods: This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA and uncorrected intermediate (60 cm and near (at 40 cm visual acuity; contrast sensitivity (CS and visual defocus curve.Results: Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision.Conclusion: Both lens combinations were able to provide good near, intermediate and distance vision

  11. Factors associated with strabismus after cataract extraction and primary intraocular lens implantation in congenital cataracts

    Directory of Open Access Journals (Sweden)

    Soo Jung Lee

    2014-06-01

    Full Text Available AIM: To evaluate factors associated with the development of strabismus after cataract extraction and primary intraocular lens implantation.METHODS: The medical records of 122 patients, aged 1.5mo to 9y, who had undergone cataract extraction with primary intraocular lens implantation between January 1993 and August 2011 were reviewed. Fourteen patients (17 eyes with strabismus before cataract surgery were excluded. Patients were divided into those with congenital bilateral cataracts (64 patients, 128 eyes and those with unilateral cataracts (44 patients, 44 eyes. The associations between the development of strabismus and age at cataract surgery, pre- and post-cataract extraction corrected distance visual acuity (CDVA, interocular CDVA difference, nystagmus, surgical method, and secondary cataract were evaluated.RESULTS: Factors significantly associated with the development of strabismus included age at cataract surgery (≤1y, preoperative mean CDVA ≤20/100, presence of nystagmus in the bilateral cataract group and postoperative interocular CDVA difference >20/70 in the unilateral group. Postoperative CDVA ≤20/100 and preservation of posterior capsule, and presence of secondary cataract were significant factors in both groups.CONCLUSION: Children with congenital cataracts should be monitored carefully after cataract surgery for the development of strabismus, especially when they underwent surgery at age ≤1y, and they have nystagmus, large postoperative interocular CDVA difference, poor preoperative and postoperative CDVA, preservation of the posterior capsule, or secondary cataract.

  12. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    Science.gov (United States)

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  13. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    César Albarrán-Diego

    2017-11-01

    Full Text Available AIM: To evaluate the clinical utility of automated refraction (AR and keratometry (KR compared with subjective or manifest refraction (MR after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH refractive multifocal intraocular lens (IOL. METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  14. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Savini, Giacomo; Hoffer, Kenneth J; Barboni, Piero

    2015-04-01

    To evaluate the possible influence of anterior corneal surface asphericity on the refractive outcomes in eyes having intraocular lens (IOL) implantation after cataract surgery. Fondazione G.B. Bietti IRCCS, Rome, Italy. Retrospective comparative case series. Intraocular lens power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Asphericity (Q-value) was measured at 8.0 mm with a Placido-disk corneal topographer (Keratron), a rotating Scheimpflug camera (Pentacam), and a rotating Scheimpflug camera combined with Placido-disk corneal topography (Sirius). The relationship between the error in refraction prediction (ie, difference between expected refraction and refraction measured 1 month after surgery) and the Q-value was assessed by linear regression. The same IOL model (Acrysof SA60AT) was implanted in 115 eyes of 115 consecutive patients. Regression analysis showed a statistically significant relationship between the error in refraction prediction and the Q-value with all formulas and all devices. In all cases, a more negative Q-value (prolate cornea) was associated with a myopic outcome, whereas a more positive Q-value (oblate cornea) was associated with a hyperopic outcome. The highest coefficient of determination was detected between the Hoffer Q formula and the Placido-disk corneal topographer (R(2) = 0.2630), for which the error in refraction prediction (y) was related to the Q-value (x) according to the formula y = -0.2641 + 1.4589 × x. Corneal asphericity influences the refractive outcomes of IOL implantation and should be taken into consideration when using third-generation IOL power formulas. Dr. Hoffer receives book royalties from Slack, Inc., Thorofare, New Jersey, and formula royalties from all manufacturers using the Hoffer Q formula. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    OpenAIRE

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    Purpose : To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior ...

  16. Correction of High Astigmatism after Penetrating Keratoplasty with Toric Multifocal Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-07-01

    Full Text Available After penetrating keratoplasty (PK, high astigmatism is often induced, being frequently about 4–6 dpt. According to the entity and typology of astigmatism, different methods of correction can be used. Selective suture removal, relaxing incisions, wedge resections, compression sutures, photorefractive keratectomy, and laser-assisted in situ keratomileusis can reduce corneal astigmatism and ametropia, but meanwhile they can cause a reduction in the corneal integrity and cause an over- or undercorrection. In case of moderate-to-high regular astigmatisms, the authors propose a toric multifocal intraocular lens (IOL implantation to preserve the corneal integrity (especially in PK after herpetic corneal leukoma keratitis. We evaluated a 45-year-old patient who at the age of 30 was subjected to PK in his left eye due to corneal leukoma herpetic keratitis, which led to high astigmatism (7.50 dpt cyl. 5°. The patient was subjected to phacoemulsification and customized toric multifocal IOL implantation in his left eye. The correction of PK-induced residual astigmatism with a toric IOL implantation is an excellent choice but has to be evaluated in relation to patient age, corneal integrity, longevity graft, and surgical risk. It seems to be a well-tolerated therapeutic choice and with good results.

  17. Visual and Refractive Outcomes after Cataract Surgery with Implantation of a New Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Cinzia Mazzini

    2013-06-01

    Full Text Available Purpose: The aim of this study was to evaluate and report the visual, refractive and aberrometric outcomes of cataract surgery with implantation of the new aspheric Tecnis ZCT toric intraocular lens (IOL in eyes with low to moderate corneal astigmatism. Methods: We conducted a prospective study of 19 consecutive eyes of 17 patients (mean age: 78 years with a visually significant cataract and moderate corneal astigmatism [higher than 1 diopter (D] undergoing cataract surgery with implantation of the aspheric Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive and aberrometric changes were evaluated during a 6-month follow-up. Ocular aberrations as well as IOL rotation were evaluated by means of the OPD-Station II (Nidek. Results: The six-month postoperative spherical equivalent and power vector components of the refractive cylinder were within ±0.50 D in all eyes (100%. Postoperative logMAR uncorrected and corrected distance visual acuities (UDVA/CDVA were 0.1 (about 20/25 or better in almost all eyes (94.74%. The mean logMAR CDVA improved significantly from 0.41 ± 0.23 to 0.02 ± 0.05 (p Conclusion: Cataract surgery with implantation of the aspheric Tecnis ZCT IOL is a predictable and effective procedure for visual rehabilitation in eyes with cataract and low to moderate corneal astigmatism, providing an excellent postoperative ocular optical quality.

  18. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  19. Corneal injection track:an unusual complication of intraocular lens implantation and review

    Directory of Open Access Journals (Sweden)

    Julie Y.C. Lok

    2015-06-01

    Full Text Available Phacoemulsification is the main gold standard for cataract operation in the developed world together with foldable intraocular lens (IOL implantation by injection, allowing for stable wound construction and less postoperative astigmatism. It is a safe procedure with high success rate with the advancement in machines, improvement of IOL injection systems and further maturation of surgeons’ techniques. Despite the large number of operations performed every day, foldable IOL injection leading to an intra-stromal corneal track is a very rare complication. We report a case of this unusual finding in a 70-year-old gentleman who has undergone cataract operation in November 2011 in our hospital and will review on the complications related to foldable IOL injection.

  20. Reverse pupillary block associated with pigment dispersion syndrome after in-the-bag intraocular lens implantation.

    Science.gov (United States)

    Itagaki, Hideo; Kunikata, Toshio; Hiratsuka, Kentaro; Saito, Junichiro; Oshika, Tetsuro

    2013-12-01

    A 61-year-old man with high myopia who had received a systemic α1A-adrenoceptor antagonist had phacoemulsification and in-the-bag intraocular lens implantation in the right eye. One day postoperatively, marked pigment dispersion in the anterior chamber, posterior bowing of the iris, and iridodonesis were noted associated with a subsequent elevation in intraocular pressure (IOP). Pharmacological pupil dilation was effective in reducing pigment dispersion and IOP, and laser peripheral iridotomy was performed to alleviate posterior bowing of the iris. We hypothesize that dynamic changes in the aqueous humor flow by cataract surgery and latent flaccidity of the iris due to the systemic α1A-adrenoceptor antagonist caused reverse pupillary block. High myopia may be another risk factor for this complication. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user

  2. Early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma: an economic evaluation based on data from the EAGLE trial

    Science.gov (United States)

    Javanbakht, Mehdi; Azuara-Blanco, Augusto; Burr, Jennifer M; Ramsay, Craig; Cooper, David; Cochran, Claire; Norrie, John; Scotland, Graham

    2017-01-01

    Objective To investigate the cost-effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma (PACG) compared to standard care. Design Cost-effectiveness analysis alongside a multicentre pragmatic two-arm randomised controlled trial. Patients were followed-up for 36 months, and data on health service usage and health state utility were collected and analysed within the trial time horizon. A Markov model was developed to extrapolate the results over a 5-year and 10-year time horizon. Setting 22 hospital eye services in the UK. Population Males and females aged 50 years or over with newly diagnosed PACG or primary angle closure (PAC). Interventions Lens extraction compared to standard care (ie, laser iridotomy followed by medical therapy and glaucoma surgery). Outcome measures Costs of primary and secondary healthcare usage (UK NHS perspective), quality-adjusted life years (QALYs) and the incremental cost-effectiveness ratio (ICER) for lens extraction versus standard care. Results The mean age of participants was 67.5 (8.42), 57.5% were women, 44.6% had both eyes eligible, 1.4% were of Asian ethnicity and 35.4% had PAC. The mean health service costs were higher in patients randomised to lens extraction: £2467 vs £1486. The mean adjusted QALYs were also higher with early lens extraction: 2.602 vs 2.533. The ICER for lens extraction versus standard care was £14 284 per QALY gained at three years. Modelling suggests that the ICER may drop to £7090 per QALY gained by 5 years and that lens extraction may be cost saving by 10 years. Our results are generally robust to changes in the key input parameters and assumptions. Conclusions We find that lens extraction has a 67–89% chance of being cost-effective at 3 years and that it may be cost saving by 10 years. Trial registration number ISRCTN44464607; Results. PMID:28087548

  3. [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

    Science.gov (United States)

    Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M

    2013-11-01

    The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.

  4. Implantation of a double iris-claw intraocular lens in an aphakic nanophthalmic eye

    Directory of Open Access Journals (Sweden)

    Filiz Avsin Ozdemir Sarioglu

    2017-01-01

    Full Text Available A 55-year-old female with an aphakic nanophthalmic eye underwent a secondary intraocular lens implantation (IOL with double Artisan aphakia iris claw IOLs (ICIOLs and was evaluated in this research. The patient's preoperative best-corrected visual acuity (BCVA of the right eye was 0.4 (0.4 logMAR (with + 21.00 D, postoperative 1st and 3rd month, 1st year, and 3 years BCVAs were 0.4 (0.4 logMAR. The intraocular pressure was 15 mmHg preoperatively, and 14, 12, 12, and 15 mmHg postoperatively at 1st and 3rd month, 1st year, and 3 years, respectively. The preoperative endothelial cell density (ECD was 2372 cells/mm2, and postoperative ECDs were 2352, 2391, 2246, and 2240 cells/mm2 at 1st and 3rd months, at 1st year, and 3 years respectively. In aphakic nanophthalmic eyes with inadequate capsular support, which require high IOL dioptry, the implantation of double ICIOLs (one in front of the iris and the other behind the iris seems to be safe and provides good visual rehabilitation.

  5. Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat

    2011-01-01

    To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.

  6. DYNAMIC CHANGES OF THE POSTERIOR POLE OF THE EYE AFTER CATARACT PHACOEMULSIFICATION WITH INTRAOCULAR LENS IMPLANTATION

    Directory of Open Access Journals (Sweden)

    M. Р. Yugay

    2017-01-01

    Full Text Available Objective. To study the effect of uncomplicated phacoemulsification through the corneal incision with implantation of the intraocular lens (IOL for changes in the macular region of the retina. Methods: The study included 35 eyes of 35 patients who underwent uncomplicated phacoemulsification with IOL implantation. The average age of the patients was 67±2,3 years, among them were 19 women and 16 men. Exclusion criteria: retinal pathology (postthrombotic and diabetic retinopathy, wet form of age-related macular degeneration and other diseases of the retina, previous eye injuries, uveitis, intra-operative complications. Retinal thickness in the fovea, the macula, and macular volume were measured by optical coherence tomography on the first day, after 2 weeks, 1 and 3 months after surgery. Results. In the period between the first day and two weeks after surgery there were the statistically significant incensement in retinal thickness in the macula from 306,64±21,15 mkm to 321,46±27,83 mkm (p <0.05, in the fovea from 211,45±20,24 mkm to 218,69±17,84 mkm (p<0.05, macular volume from 8,08±0,35 cubic mm to 8,46±0,54 cubic mm were registered. By the end of the first month after surgery maximum retinal thickness was 327,23±27,16 mkm, thickness in the fovea 220,31±18,63 mkm, macular volume 8,61±0,55 cubic mm. After 3 months, the maximum thickness of the retina reached 325,11±26,13 mkm, in the fovea 220,31±18,63 mkm, macular volume 8,55±0,49 cubic mm. Conclusion. There was an incensement of macular volume and retinal thickness in the period between the first day and two weeks after uncomplicated cataract phacoemulsification with intraocular lens implantation. The growth of these indicators continued within the first month after surgery, three months after phacoemulsification there was a downward trend. This can be important in determining the duration of drug therapy in the postoperative period.

  7. Preoperative Biometric Parameters Predict the Vault after ICL Implantation: A Retrospective Clinical Study.

    Science.gov (United States)

    Zheng, Qian-Yin; Xu, Wen; Liang, Guan-Lu; Wu, Jing; Shi, Jun-Ting

    2016-01-01

    To investigate the correlation between the preoperative biometric parameters of the anterior segment and the vault after implantable Collamer lens (ICL) implantation via this retrospective study. Retrospective clinical study. A total of 78 eyes from 41 patients who underwent ICL implantation surgery were included in this study. Preoperative biometric parameters, including white-to-white (WTW) diameter, central corneal thickness, keratometer, pupil diameter, anterior chamber depth, sulcus-to-sulcus diameter, anterior chamber area (ACA) and central curvature radius of the anterior surface of the lens (Lenscur), were measured. Lenscur and ACA were measured with Rhinoceros 5.0 software on the image scanned with ultrasound biomicroscopy (UBM). The vault was assessed by UBM 3 months after surgery. Multiple stepwise regression analysis was employed to identify the variables that were correlated with the vault. The results showed that the vault was correlated with 3 variables: ACA (22.4 ± 4.25 mm2), WTW (11.36 ± 0.29 mm) and Lenscur (9.15 ± 1.21 mm). The regressive equation was: vault (mm) = 1.785 + 0.017 × ACA + 0.051 × Lenscur - 0.203 × WTW. Biometric parameters of the anterior segment (ACA, WTW and Lenscur) can predict the vault after ICL implantation using a new regression equation. © 2016 The Author(s) Published by S. Karger AG, Basel.

  8. Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Wojciech Lubiński

    2016-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA and corrected distance visual acuity (CDVA were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001, while keratometric cylinder did not change significantly (p=0.44. Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%. Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied to 10 (very satisfied. No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.

  9. Toric intraocular lens implantation versus astigmatic keratotomy to correct astigmatism during phacoemulsification.

    Science.gov (United States)

    Titiyal, Jeewan S; Khatik, Mukesh; Sharma, Namrata; Sehra, Sri Vatsa; Maharana, Parfulla K; Ghatak, Urmimala; Agarwal, Tushar; Khokhar, Sudarshan; Chawla, Bhavana

    2014-05-01

    To compare toric intraocular lens (IOL) implantation and astigmatic keratotomy (AK) in correction of astigmatism during phacoemulsification. Tertiary care hospital. Prospective randomized trial. Consecutive patients with visually significant cataract and moderate astigmatism (1.25 to 3.00 diopters [D]) were randomized into 2 groups. Temporal clear corneal 2.75 mm phacoemulsification with toric IOL implantation was performed in the toric IOL group and with 30-degree coupled AK at the 7.0 mm optic zone in the keratotomy group. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, keratometry, topography, central corneal thickness, and endothelial cell density were evaluated preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. The study enrolled 34 eyes (34 patients), 17 in each group. There was no difference in UDVA or CDVA between the 2 groups at any follow-up visit. The mean preoperative and postoperative refractive cylinder was 2.00 D ± 0.49 (SD) and 0.33 ± 0.17 D, respectively, in the toric IOL group and 1.95 ± 0.47 D and 0.57 ± 0.41 D, respectively, in the keratotomy group (P=.10). The mean residual astigmatism at 3 months was 0.44 ± 1.89 @ 160 in the toric IOL group and 0.77 ± 1.92 @ 174 in the keratotomy group (P=.61). All eyes in the toric IOL group and 14 eyes (84%) in the keratotomy group achieved a residual refractive cylinder of 1.00 D or less (P=.17). Toric IOL implantation was comparable to AK in eyes with moderate astigmatism having phacoemulsification. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children.

    Science.gov (United States)

    Das, Pranab; Ram, Jagat; Brar, Gagandeep Singh; Dogra, Mangat R

    2009-01-01

    To evaluate the outcome of intraocular lens (IOL) implantation using capsular tension ring (CTR) in subluxated crystalline or cataractous lenses in children. Tertiary care setting. We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90 degrees up to 210 degrees after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO). Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA) in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG) laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation.

  11. Results of intraocular lens implantation with capsular tension ring in subluxated crystalline or cataractous lenses in children

    Directory of Open Access Journals (Sweden)

    Das Pranab

    2009-01-01

    Full Text Available Purpose : To evaluate the outcome of intraocular lens (IOL implantation using capsular tension ring (CTR in subluxated crystalline or cataractous lenses in children. Setting : Tertiary care setting Materials and Methods : We prospectively studied 18 eyes of 15 children with subluxation of crystalline or cataractous lenses between 90° up to 210° after phacoemulsification, CTR and IOL implantation. Each child was examined for IOL centration, zonular dehiscence and posterior capsular opacification (PCO. Results : Age of the patient ranged between five to 15 years. Out of 18 eyes, seven had traumatic and 11 had spontaneous subluxation of crystalline or cataractous lens. Phacoemulsification was successfully performed with CTR implantation in the capsular bag. Intraoperative zonular dialysis occurred in two eyes. Anterior vitrectomy was performed in six eyes to manage vitreous prolapse. IOL implanted was polymethyl methacrylate (PMMA in eight eyes, hydrophobic acrylic in seven and hydrophilic acrylic in three. Follow-up ranged from 24 months to 72 months. Sixteen eyes had a best corrected visual acuity of 20/40 or better. Nine eyes developed significant PCO and were managed with Neodymium Yttrium Aluminum Garnet (Nd:YAG laser posterior capsulotomy. One eye with acrylic IOL in the capsular bag had IOL dislocation after two years which was managed with vitrectomy and secondary trans-scleral fixation of IOL. Conclusions : Phacoaspiration with CTR implantation makes capsular bag IOL fixation possible in most of the eyes with subluxated crystalline or cataractous lenses. PCO still remains a challenge in children with successful phacoaspiration with CTR implantation

  12. Contrast visual acuity after multifocal intraocular lens implantation:aspheric versus spherical design

    Directory of Open Access Journals (Sweden)

    Jun-Hua Li

    2014-02-01

    Full Text Available AIM: To evaluate contrast visual acuity (CVA after implantation of an aspheric apodized diffractive intraocular lens (IOL or a spherical apodized diffractive IOL in cataract surgery.METHOD: This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL (30 eyes and a spherical AcrySof ReSTOR SN60D3 IOL (30 eyes. CVA with best distance correction was measured at 4 contrast levels (100%, 25%, 10% and 5% under 3 levels of chart luminance [250, 85 and 25 candelas per square meter (cd/m2] using a multi-functional visual acuity tester (MFVA-100.RESULTS:At 12 months after surgery, there were no statistically significant differences in 100% CVA and 25% CVA under 250cd/m2 (P100%=0.875 and P25%=0.057 and 85cd/m2 (P100%=0.198 and P25%=0.193 between the aspheric group and the spherical group. However, the 10% CVA and 5% CVA were significant better in aspheric group than spherical group under 250cd/m2 (P10%=0.042 and P5%=0.007 and 85cd/m2 (P10%=0.002 and P5%=0.039. Under the luminance level of 25cd/m2, no significant differences was found in the 100% CVA between the 2 group (P100%=0.245, while aspheric group had better visual acuity in the remaining 3 contracts (P25%=0.023, P10%=0.026 and P5%=0.002, respectively.CONCULSION:The aspheric AcrySof ReSTOR SN6AD3 IOL provided patients with better low-contrast visual acuity than the spherical AcrySof ReSTOR SN60D3 IOL.Keyword:cataract surgery; intraocular lens; contrast sensitivity; visual acuity

  13. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    OpenAIRE

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Opht...

  14. Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Talita Shimoda

    2014-04-01

    Full Text Available Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC was -2.19 (SD: ± 0.53. After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001. Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.

  15. Safety assessment of a new single-use small-incision injector for intraocular lens implantation.

    Science.gov (United States)

    Satanovsky, Alexandra; Ben-Eliahu, Shmuel; Apple, David J; Kleinmann, Guy

    2011-07-01

    To evaluate the safety of a new injector, the Raysert R-INJ-04/18, for implantation of the C-flex intraocular lens (IOL). Ophthalmology Department, Kaplan Medical Center, Rehovot, Israel. Experimental study. Sixty IOLs were subdivided into 2 equally sized groups. Group A IOLs were injected using the established R-INJ-04 injector, and those in Group B were injected with the new injector. The IOLs were injected into a Petri dish. Subsequently, all IOLs and injectors were evaluated macroscopically and microscopically and then photographed under light microscopy (LM). Two IOLs in each group were randomly chosen and sent for evaluation by scanning electron microscopy (SEM) and energy dispersive analysis of x-ray. All remaining IOLs were sent for power and modulation transfer function (MTF) analysis. All Group B IOLs were successfully injected without evident signs of scratching, cracks, or deposits on LM and SEM examination. In Group A, findings were confined to a singular incidence of a small deposit detected on the periphery of the posterior optical surface of the IOL, with corresponding findings detected on the injector nozzle. No signs of scratching, cracks, or deposits were found in the rest of the IOLs or injectors. The power and MTF analyses were within the normal range for all IOLs. The new 1.8 mm external diameter soft-tipped injector for 2.4 to 2.2 mm incisions was shown to be safe for the implantation of the C-flex 21.0 diopter IOL. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Comparison of the effects of intraocular irrigating solutions on the corneal endothelium in intraocular lens implantation.

    Science.gov (United States)

    Matsuda, M; Kinoshita, S; Ohashi, Y; Shimomura, Y; Ohguro, N; Okamoto, H; Omoto, T; Hosotani, H; Yoshida, H

    1991-01-01

    We conducted a randomised prospective controlled study to determine the effects of a glucose glutathione bicarbonate solution (BSS Plus) and a citrate acetate bicarbonate solution (S-MA2) on the corneal endothelium in patients undergoing extracapsular cataract extraction with posterior chamber lens implantation. One eye of each patient was randomly assigned to receive BSS Plus, and the other eye to receive S-MA2. BSS Plus caused significantly less corneal swelling on the first postoperative day than did S-MA2. There was no difference between the two solutions in their effect on corneal thickness one week and one month postoperatively. Computer assisted morphometric analysis of wide-field specular microscopic photographs demonstrated minimal changes in endothelial morphological characteristics in the eyes irrigated with BSS Plus. By comparison S-MA2, caused a significant loss of endothelial cells and a marked reduction in the figure coefficient. These results indicated that BSS Plus has a clinical advantage over S-MA2 with respect to the corneal endothelium. PMID:1873266

  17. Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error

    Directory of Open Access Journals (Sweden)

    Alahmady Hamad Alsmman Hassan

    2016-01-01

    Full Text Available In this study we evaluate the visual outcomes, safety, efficacy, and stability of implanting of second sulcus intraocular lens (IOL to correct unsatisfied ametropic patients after phacoemulsification. Methods. Retrospective study of 15 eyes (15 patients underwent secondary intraocular lens implanted into the ciliary sulcus. The IOL used was a Sensar IOL three-piece foldable hydrophobic acrylic IOL. The first IOL in all patients was acrylic intrabagal IOL implanted in uncomplicated phacoemulsification surgery. Results. Fifteen eyes (15 patients were involved in this study. Preoperatively, mean log⁡MAR UDVA and CDVA were 0.88 ± 0.22 and 0.19 ± 0.13, respectively, with a mean follow-up of 28 months (range: 24 to 36 months. At the end of the follow-up, all eyes achieved log⁡MAR UDVA of 0.20 ± 0.12 with postoperative refraction ranging from 0.00 to −0.50 D of attempted emmetropia. Conclusions. Implantation of the second sulcus SensarAR40 IOL was found to be safe, easy, and simple technique for management of ametropia following uncomplicated phacoemulsification.

  18. Analysis of incidence and related factors on effusion of anterior chamber after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Bing-Bing Zhao

    2018-02-01

    Full Text Available AIM: To investigate the incidence and related factors on effusion of anterior chamber(ACafter phacoemulsification(PEcombined with intraocular lens(IOLimplantation. METHODS: Totally 359 cases of cataract(375 eyesunderwent PE combined with IOL implantation were collected in our hospital. The incidence of AC exudation after operation and related factors were analyzed by single factor and multiple logistic regression analysis. RESULTS: The group was included in 359 cases(375 eyes. The incidence of postoperative AC exudation in the study group was 5.9%(22/375. The preoperative intraocular pressure(IOP, visual acuity before and after surgery, nuclear grades, posterior capsular rupture(PCRrate and ultrasonic accumulated energy complex parameter(AECPof the study group showed statistically significant difference compared with the control group(all P21mmHg, intraoperative pupil diameter 7.25(%×min, the lens nucleus grade ≥ IV were risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all P21mmHg, ultrasound AECP >7.25 were independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all PCONCLUSION: High myopia, glaucoma, uveitis, the lens nucleus grade ≥ IV, the incidence of intraoperative PCR, preoperative IOP>21mmHg, ultrasonic AECP>7.25 are independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract, with such risk factors in patients with cataract should be paid closely attention and timely diagnosis and treatment in clinic.

  19. Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience.

    Science.gov (United States)

    Nekolova, Jana; Rozsival, Pavel; Sin, Martin; Jiraskova, Nada

    2017-06-01

    To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.

  20. Changes in the accommodation-convergence relationship after the Artisan phakic intraocular lens implantation for myopic patients.

    Science.gov (United States)

    Ryu, Ik Hee; Han, Jinu; Lee, Hyung Keun; Kim, Jin Kook; Han, Sueng-Han

    2014-04-01

    To evaluate the change of accommodation-convergence parameters after implantation of Artisan phakic intraocular lens (PIOL). Prospective study for the patients with the Artisan PIOL implantation was performed. A total of 37 patients (3 males and 34 females) enrolled the study. Preoperatively, convergence amplitude, the stimulus accommodative convergence per unit of accommodation (AC/A) ratio and the near point of convergence (NPC) were evaluated. After the Artisan PIOL implantation, the identical evaluations were repeated at 1 week, 1, 3, and 6 months after the surgery. Mean age was 24.3 ± 4.8 years old, and preoperative refractive error was -8.92 ± 4.13 diopters (D). After the implantation, mean refractive errors significantly decreased to within ±1.00 D, and noticeable complications were not found. The convergence amplitude and the stimulus AC/A ratio increased 1 month after the surgery, but progressively stabilized afterward to near preoperative values. NPC didn't show any significant change over follow-up period up to 6 months. These results regarding implantation of the Artisan PIOL revealed the increase of accommodation-convergence relationship within first 1 month after the surgery, but progressive stabilization was noted during follow-up periods.

  1. Primary versus secondary intraocular lens implantation in the management of congenital cataract

    Directory of Open Access Journals (Sweden)

    Thanaa H Mohamed

    2016-01-01

    Conclusion Primary IOL implantation was found to be safe and effective in the management of congenital cataract; it leads to lower incidence of complications and better visual outcomes compared with aphakia and secondary IOL implantation.

  2. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty.

    Science.gov (United States)

    Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D

    2018-01-01

    We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  3. Iris-fixated phakic intraocular lens implantation to correct myopia and a predictive model of endothelial cell loss.

    Science.gov (United States)

    Bouheraoua, Nacim; Bonnet, Clemence; Labbé, Antoine; Sandali, Otman; Lecuen, Nicolas; Ameline, Barbara; Borderie, Vincent; Laroche, Laurent

    2015-11-01

    To report long-term results of Artisan phakic intraocular lens (pIOL) to correct myopia and to propose a model predicting endothelial cell loss after pIOL implantation. Quinze-Vingts National Ophthalmology Hospital, Paris, France. Retrospective, interventional case series. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and central endothelial cell count (ECC) were determined before and at yearly intervals up to 5 years after pIOL implantation. Linear model analysis was performed to present a model that describes endothelial cell loss as a linear decrease and an additional decrease depending on postoperative loss. A total of 49 patients (68 eyes) implanted with pIOLs from January 2000 to January 2009 were evaluated. The mean preoperative and final spherical equivalent (SE) were -13 ± 4.10 and -0.75 ± 0.74 diopters (D), respectively. The mean preoperative and final central ECC were 2629 ± 366 and 2250 ± 454 cells/mm(2), respectively. There were no intraoperative complications for any of the eyes. One eye required surgery for repositioning the pIOL, and 1 eye required pIOL exchange for postoperative refractive error. The model predicted that for patients with preoperative ECC of 3000, 2500, and 2000 cells/mm(2), a critical ECC of 1500 cells/mm(2) will be reached at 39, 28, and 15 years after implantation, respectively. Implantation of the pIOL was an effective and stable procedure after 5 years of follow-up. The presented model predicted EC loss after pIOL implantation, which can assist ophthalmologists in patient selection and follow-up. The authors report no conflict of interest. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. [Slit lamp optical coherence tomography study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation].

    Science.gov (United States)

    Yan, Pi-song; Zhang, Zhen-ping; Lin, Hao-tian; Wu, Wen-jie; Bai, Ling

    2009-09-01

    To investigate quantitative changes of the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation with slit-lamp-adapted optical coherence tomography (SL-OCT). In prospective consecutive case series, clear corneal incision phacoemulsification and foldable intraocular lens implantation were performed in 44 eyes of 40 patients. The changes of the anterior segment configuration were performed by SL-OCT before and 1 day, 1 week, 2 weeks and 1 month after surgery. SPSS 16.0 software was used to analyze statistical difference. For all patients, the central corneal thickness (CCT) and the incisional corneal thickness (ICT) increased significantly 1 day after surgery (CCT increased 99.59 microm, ICT increased 234.57 microm; P = 0.490). At 1 month, the CCT almost had returned to baseline, but the ICT had been thicker about 19.25 microm than baseline(P = 0.001). The measurements of ACD, AOD500, AOD750, TISA500, TISA750 also increased significantly 1 day after surgery. Although the ACD had no changes within 2 weeks (all P 0.05). The SL-OCT could impersonality and quantificationally evaluate the anterior segment changes induced by cataract surgery.

  5. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma.

    Science.gov (United States)

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. Non-comparative retrospective observational case series. 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. To take early treatment of traumatic lens

  6. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  7. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    Science.gov (United States)

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  8. Cionni ring and in-the-bag intraocular lens implantation for subluxated lenses: a prospective case series.

    Science.gov (United States)

    Vasavada, Abhay R; Praveen, Mamidipudi R; Vasavada, Viraj A; Yeh, Ru-Yin; Srivastava, Samaresh; Koul, Archana; Trivedi, Rupal H

    2012-06-01

    To report the intraoperative performance and postoperative outcomes of the Cionni-modified capsule tension ring (CTR) implantation in eyes with subluxated lenses. Prospective, observational case series. This study was carried out at Iladevi Cataract & IOL Research Centre, Ahmedabad, India. The study population comprised 41 eyes with subluxated lenses that underwent lens extraction, capsular bag fixation with modified CTR, and in-the-bag single-piece AcrySof intraocular lens (IOL) implantation. Main outcome measures were intraoperative performance and postoperative best-corrected visual acuity (BCVA), IOL centration, and complications. The mean age was 29.46 ± 16.16 years (3-68 years). Mean extent of subluxation was 6.1 ± 1.0 clock hours. Preoperatively, vitreous was detected in the anterior chambers of 5 eyes (12.2%). Two-port anterior chamber vitrectomy was performed in 2 eyes. Mean follow-up was 45.8 ± 2.9 months. Mean preoperative BCVA was 0.66 ± 0.22 logMAR (35 eyes). Mean postoperative BCVA at final follow-up was 0.33 ± 0.21 logMAR (41 eyes) (P IOL decentration was noted and repositioning was required in 2 eyes. Posterior capsule opacification developed in 14 eyes (34.2%); 12 eyes (29.3%) required Nd:YAG capsulotomy. Other complications included cystoid macular edema in 1 eye (2.4%), posterior synechiae in 1 eye (2.4%), and retinal detachment in 1 eye (2.4%). In-the-bag implantation of a Cionni-modified CTR with IOL appears to be a safe option in eyes with subluxated cataract, ensuring a stable IOL with few complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  10. Facoemulsificación e implante de lente intraocular en cataratas causadas por uveitis Phacoemulsification and intraocular lens implantation in patients with cataract caused by uveitis

    Directory of Open Access Journals (Sweden)

    Dayamí Pérez Gómez

    2008-06-01

    Full Text Available OBJETIVO: Evaluar los resultados de la facoemulsificación y el implante de lente intraocular en cataratas causadas por uveítis. MÉTODOS: Se estudiaron 37 ojos con 6 meses de inactividad inflamatoria, agudeza visual menor de 0,6 y edad media de 47 años. Se excluyeron otras enfermedades que disminuyeran la visión. En el preoperatorio se prescribió antiinflamatorios. Se realizó la facoemulsificación con implante de lente intarocular (PMMA, óptica 6 mm; durante el seguimiento desde 24 h/6 meses se indicó antiinflamatorios esteroideos, no esteroideos e inmunosupresores hasta 6 semanas. RESULTADOS: Se observaron numerosas alteraciones del segmento anterior secundarias a las uveítis padecidas (posquirúrgicas, inespecíficas, ciclítis heterocrómica de Fuchs, postraumáticas, síndrome de Reiter, por toxoplasmosis y otras coroiditis infecciosas y por artritis reumatoide juvenil. No hubo recurrencia posquirúrgica de la uveítis en 9 ojos (24,3 %. Las complicaciones estuvieron relacionadas con la uveítis, la cirugía, la actividad inflamatoria, y la reacción del epitelio capsular. La opacidad capsular posterior apareció en 11 pacientes (29,7 % asociada a edad joven. La evolución individual se consideró satisfactoria en 30 (81,1 % pacientes con mejoría de la visión hasta 0,8-1,0 en 28 (75,6 % y 0,5-0,6 en 2 (5,4 %. CONCLUSIONES: La facoemulsificación con implante de lente intarocular es de gran utilidad en las cataratas posuveítis al condicionar poca agresión quirúrgica, ser controlable la inflamación y proporcionar buenos resultados visuales además del reordenamiento anatomofisiológico del segmento anterior.OBJECTIVE: To assess the results of phacoemulsification and intraocular lens implantation in cataracts caused by uveitis. METHODS: Thirty seven eyes with no inflammation for 6 months, visual acuity below 0.6 and average age of 47 years were studied. Other diseases affecting the vision were excluded. The preoperative

  11. Fixed mydriatic pupil associated with an intraocular pressure rise as a complication of the implant of a Phakic Refractive Lens (PRL).

    Science.gov (United States)

    Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro

    2014-07-01

    We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

  12. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation.

    Science.gov (United States)

    Kawamorita, Takushi; Uozato, Hiroshi; Shimizu, Kimiya

    2012-06-01

    A modified implantable collamer lens (ICL) with a central hole (diameter, 0.36 mm), a "Hole-ICL", was created to improve aqueous humour circulation. The aim of this study was to investigate the fluid dynamic characteristics of aqueous humour in a Hole-ICL using computational fluid dynamics. Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V5 (Mentor Graphics Corp.). For the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with conventional ICL (Model ICM, STAAR SURGICAL) and a Hole-ICL were used. Both ICLs were -9.0 diopters (D) and 12.0 mm in length, with an optic of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μl/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was also calculated, and trajectory analysis was performed. The flow velocity 0.25 mm in front of the centre of the crystalline lens was 1.52 × 10(-1) mm/sec for the Hole-ICL and 1.21 × 10(-5) mm/sec for the conventional ICL. Outward flow from the hole in the Hole-ICL was confirmed by trajectory analysis. These results suggest that Hole-ICLs improve the circulation of aqueous humour to the anterior surface of the crystalline lens.

  13. Functional and refractive results after one month of AcrySof toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Francisco Alba-Bueno

    2011-04-01

    Conclusions: The implantation of SN60T toric IOL in patients with CA higher than 0.75 D is a safe, predictable and effective way of reducing refractive astigmatism in patients undergoing cataract surgery.

  14. Clinical application of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract

    Directory of Open Access Journals (Sweden)

    Qing-Song Gao

    2018-02-01

    Full Text Available AIM:To evaluate the effect of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract. METHODS: Totally 86 cases(106 eyesof patients with double cataract in our hospital from January 2016 to January 2017 were selected, including 49 cases(59 eyeswere set as the observation group(treated with femtosecond laser assisted phacoemulsification combined with triple-focus intraocular lens implantation, and 37 cases(47 eyeswere set as the control group(received traditional phacoemulsification combined with triple-focus intraocular lens implantation. Corneal endothelial cell density, cumulative dissipated energy(CDE, distant and near visual accommodation before and after operation were compared between the two groups, postoperative complications were observed. RESULTS: The preoperative corneal endothelial cell density of two groups had no significant difference(P>0.05. The corneal endothelial cell density of two groups significantly decreased at postoperative 1wk, with statistic significance within groups(PPPPPP>0.05. The incidence of glare and halo in the observation group was 10.2% and 8.5% in the control group, and are in the patients whose age was above 60 years old, there was no significant difference between the two groups(P>0.05. CONCLUSION: Femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract can not only improve curative effect, but also provide high safety, while the adverse events including glare, halo and other adverse visual circumstances should be considered after triple-focus intraocular lens implantation.

  15. Efficacy of different kinds of artificial tears treatment in patients with xerophthalmia after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yu-Xia Ruan

    2017-09-01

    Full Text Available AIM: To explore efficacy of the different kinds of artificial tears treatment in patients with xerophthalmia after phacoemulsification combined with intraocular lens implantation.METHODS: Totally 280 patients(280 eyeswith xerophthalmia after operation in our hospital from January 2015 to June 2016 were selected. According to the different treatment methods, they were divided into control group(n=70; treated with tobramycin and dexamethasone eye ointment 3 times per day for 1wk, levofloxacin eye drops 3 times per day for 1wk, pranoprofen eye drops 4 times per day for 1mo, polyacrylic acid group(n=70; besides the treatment of control group, polyacrylic acid was used 4 times per for 1mo, polyethylene glycol group(n=70; besides the treatment of control group, polyethylene glycol was used 4 times per for 1moand sodium hyaluronate group(n=70; besides the treatment of control group, sodium hyaluronate was used 4 times per for 1mo. The tear film break up time(BUT, Schirmer Ⅰ test(SⅠt, symptoms of dry eye and corneal staining in four groups were observed. RESULTS:(1BUT: The BUT of the four groups significantly increased after treatment(PPPPPPPPPPP>0.05; sodium hyaluronate group was significant lower than other groups in corneal staining score at 3wk and 1mo after treatment(PCONCLUSION: Artificial tears in the treatment of xerophthalmia after cataract phacoemulsification combined with intraocular lens implantation has better clinical efficacy, which contains sodium hyaluronate may be the better than others.

  16. Phacoemulsification with intraocular lens implantation in primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma with cataract

    Directory of Open Access Journals (Sweden)

    Kun Zeng

    2013-08-01

    Full Text Available AIM: To evaluate the features and clinical outcomes of cataract extraction by phacoemulsification with intraocular lens implantation in primary angle-closure suspect(PACS, primary angle-closure(PACand primary angle-closure glaucoma(PACGwith cataract.METHODS:Phacoemulsification with intraocular lens implantation was performed on 86 cases(86 eyesdiagnosed as PACS, PAC and PACG co-existing cataract from January to December 2012. All cases were followed up for 3 months to 1 year. Pre-operative and post-operative visual acuity, intraocular pressure(IOP, gonioscopy, ultrasound biomicroscopy(UBM, visual field and usage of anti-glaucomaous eye drops were recorded.RESULTS:Zonular dialysis existed in 19 eyes(22%. The post-operative visual acuity improved in 84 eyes(98%. The post-operative visual acuity was CONCLUSION: PACS, PAC and PACG co-existing zonular dialysis is common. Phacoemulsification with IOL implantation can reduce IOP, deepen anterior chamber and open angle.

  17. Customized toric intraocular lens implantation for correction of extreme corneal astigmatism due to corneal scarring

    Directory of Open Access Journals (Sweden)

    R Bassily

    2010-03-01

    Full Text Available R Bassily, J LuckOphthalmology Department, Royal United Hospital, Combe Park, Bath, UKAbstract: A 76-year-old woman presented with decreased visual function due to cataract formation. Twenty-five years prior she developed right sided corneal ulceration that left her with 10.8 diopters (D of irregular astigmatism at 71.8° (steep axis. Her uncorrected visual acuity was 6/24 and could only ever wear a balanced lens due to the high cylindrical error. Cataract surgery was planned with a custom designed toric intraocular lens (IOL with +16.0 D sphere inserted via a wound at the steep axis of corneal astigmatism. Postoperative refraction was -0.75/+1.50 × 177° with a visual acuity of 6/9 that has remained unchanged at six-week follow-up with no IOL rotation. This case demonstrates the value of high power toric IOLs for the correction of pathological corneal astigmatism.Keywords: intraocular lens, corneal ulceration, visual acuity, scarring

  18. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag.

    Science.gov (United States)

    Kohnen, Thomas; Kook, Daniel

    2009-08-01

    We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.

  19. Evaluation of an interlaced triple procedure: penetrating keratoplasty, extracapsular cataract extraction, and nonopen-sky intraocular lens implantation.

    Science.gov (United States)

    Yang, Shuo; Wang, Bin; Zhang, Yangyang; Zhai, Hualei; Wang, Junyi; Wang, Shuang; Xie, Lixin

    2017-09-01

    To evaluate an interlaced triple procedure that involved penetrating keratoplasty (PKP), extracapsular cataract extraction (ECCE) using diathermy capsulotomy, and nonopen-sky intraocular lens (IOL) implantation.This retrospective study involved data from 34 patients who were diagnosed with severe corneal opacities and cataracts. These patients were divided into an interlaced procedure group (21 patients) and a traditional procedure group (13 patients). In the interlaced group, the method of continuous curvilinear capsulorhexis (CCC) was completed via diathermy capsulotomy. The donor corneal button was sutured at 8 positions (at equal intervals) using 10-0 nylon sutures, and the IOL was inserted into the capsular bag using a closed anterior chamber approach at the 10:30 to 12 o'clock positions between the sutures. In the traditional group, CCC was completed using side-port capsular forceps, and the IOL was implanted using an open anterior chamber approach.In the interlaced group, the CCC, open-sky, and total operation times were significantly shorter than in the traditional group (P < .05). Neither the best-corrected visual acuity (BCVA) nor corneal endothelial cell density was significantly different between the groups at 1 and 6 months after the operation.This interlaced triple procedure for the treatment of corneal diseases with cataracts appears to be feasible and practical.

  20. Quality of vision in patients implanted with aspherical and spherical intraocular lens: Intraindividual comparison

    Directory of Open Access Journals (Sweden)

    Francesco Semeraro

    2014-01-01

    Full Text Available Aims: To compare the quality of vision in pseudophakic patients implanted with aspherical and spherical intraocular lenses (IOLs. Materials and Methods: Randomized prospective longitudinal intrapatient comparison between aspherical and spherical IOLs performed on 22 patients who underwent bilateral cataract surgery. Best corrected visual acuity, subjective contrast sensitivity, Strehl ratio and spherical aberrations (SA, and higher order wavefront aberrations for a 3.5 mm and a 6.0 mm pupil were measured after 3 months of cataract surgery. Results: SA (Z4,0 decreased significantly in eyes with aspherical IOL implant (P = 0.004. Modulation transfer function (MTF and point spread function (PSF resulted no significant difference between the two groups (P = 0.87; P = 0.32. Conclusion: Although the SA is significantly lower in eyes implanted with aspherical IOL, the quality of vision determined with MTF and PSF does not significantly differ for subjective and objective parameters that were analyzed.

  1. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

    Science.gov (United States)

    García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián

    2018-01-01

    To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

  2. Complications and visual outcomes after glued foldable intraocular lens implantation in eyes with inadequate capsules.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Packiyalakshmi, Sathiya; Jacob, Soosan; Agarwal, Athiya

    2013-08-01

    To evaluate the complications and visual outcomes of glued intrascleral-fixated foldable intraocular lens (IOL) in eyes with deficient capsules. Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, India. Case series. Data were evaluated from the records of patients with a primary glued foldable IOL for intraoperative capsular loss or subluxated lens or secondary glued foldable IOL for aphakia. Exclusion criteria included preoperative glaucoma, aniridia, macular scar, traumatic subluxation, combined surgeries, incomplete operative medical records, and postoperative follow-up less than 6 months. The intraoperative and postoperative complication rates, reoperation rate, and visual outcomes were analyzed. The study comprised 208 eyes (185 patients). The mean follow-up was 16.7 months ± 10.2 (SD). The intraoperative complications were hyphema (0.4%), haptic breakage (0.4%), and deformed haptics (0.9%). Early complications occurred in 29 eyes (13.9%) and included corneal edema (5.7%), epithelial defect (1.9%), and grade 2 anterior chamber reaction (2.4%). Late complications occurred in 39 eyes (18.7%) and included optic capture (4.3%), IOL decentration (3.3%), haptic extrusion (1.9%), subconjunctival haptic (1.4%), macular edema (1.9%), and pigment dispersion (1.9%). Reoperation was required in 16 eyes (7.7%). Haptic position was altered in eyes with IOL decentration. Corrected distance visual acuity (CDVA) improved or remained unchanged in 84.6% of eyes. The postoperative CDVA was 20/40 or better and 20/60 or better in 38.9% and 48.5% of eyes, respectively. The foldable glued-IOL procedure showed satisfactory visual outcomes without serious complications. Intraocular lens decentration was due to haptic-related problems. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Effects of V4c-ICL Implantation on Myopic Patients’ Vision-Related Daily Activities

    Directory of Open Access Journals (Sweden)

    Taixiang Liu

    2016-01-01

    Full Text Available The new type implantable Collamer lens with a central hole (V4c-ICL is widely used to treat myopia. However, halos occur in some patients after surgery. The aim is to evaluate the effect of V4c-ICL implantation on vision-related daily activities. This retrospective study included 42 patients. Uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA, intraocular pressure (IOP, endothelial cell density (ECD, and vault were recorded and vision-related daily activities were evaluated at 3 months after operation. The average spherical equivalent was -0.12±0.33 D at 3 months after operation. UCVA equal to or better than preoperative BCVA occurred in 98% of eyes. The average BCVA at 3 months after operation was -0.03±0.07 LogMAR, which was significantly better than preoperative BCVA (0.08±0.10 LogMAR (P=0.029. Apart from one patient (2.4% who had difficulty reading computer screens, all patients had satisfactory or very satisfactory results. During the early postoperation, halos occurred in 23 patients (54.8%. However there were no significant differences in the scores of visual functions between patients with and without halos (P>0.05. Patients were very satisfied with their vision-related daily activities at 3 months after operation. The central hole of V4c-ICL does not affect patients’ vision-related daily activities.

  4. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-05-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To compare the visual acuity (VA and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye.Patients and methods: Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated.Results: Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05 at vergences from -0.5 to -1.5 D (from 2 m to 67 cm viewing distance, P<0.05. There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05.Conclusion: Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at

  5. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-04-01

    Full Text Available AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi''an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures:visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations.RESULTS: The follow-up time was 11-36mo (21.4±7.13. Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL

  6. Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting.

    Science.gov (United States)

    Lockington, David; Ali, Noor Q; Al-Taie, Rasha; Patel, Dipika V; McGhee, Charles N J

    2014-04-01

    To evaluate the outcomes of transscleral sutured posterior chamber intraocular lens (PC IOL) implantation. Public university hospital, Auckland, New Zealand. Retrospective case series. A modified no-touch transscleral sutured PC IOL implantation technique with a 1-piece monofocal IOL (Alcon CZ70BD) or an aniridia IOL (type 67G, Morcher) was assessed. Seventy-eight cases (80.8% men; 53.9% aphakic) were identified. The mean follow-up was 35.5 months and the mean age at surgery, 41 years±21 (SD). The preoperative corrected distance visual acuity (CDVA) was worse than 6/30 in 66.7%. Indications included ocular trauma (46.2%), nontraumatic crystalline lens subluxation (16.7%), post-complicated cataract surgery (10.3%), idiopathic IOL dislocation (10.3%), and congenital cataract/aphakia (10.3%). An aniridia IOL was required in 39.7% of eyes. There were no significant intraoperative complications in 74.4% of eyes. Postoperative complications included transient corneal edema (15.4%), wound leak requiring resuturing (7.7%), retinal detachment (7.7%), and cystoid macular edema (6.4%). One eye (1.3%) developed suture breakage-related late IOL dislocation. Overall, 91.3% of eyes had improved visual acuity or were within 1 line of the presenting CDVA. In eyes with a guarded prognosis, 34.8% achieved a CDVA of 6/12 or better and 43.5% a CDVA of 6/15 to 6/48. In the better prognosis group, 73.9% achieved a CDVA of better than 6/12 and all achieved better than 6/30. Scleral-sutured IOLs achieved good visual outcomes in a public hospital setting. The rate of complications was moderate in this series with a high proportion of severe ocular trauma and a large percentage of aniridia IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. [Refractive precision and objective quality of vision after toric lens implantation in cataract surgery].

    Science.gov (United States)

    Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J

    2012-10-01

    To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  8. Comparison of the Results of Secondary Anterior Chamber and Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Phacoemulsification Cases

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2014-03-01

    Full Text Available Objectives: To compare the visual prognosis and postoperative complication rates of secondary anterior chamber (AC IOL and scleralfixated (SF intraocular lenses (IOL after complicated phacoemulsification surgery. Materials and Methods: Thirty eyes of thirty patients were reviewed for this retrospective study. The patients with secondary AC IOL implantation formed group 1 (n=15, and the patients with secondary SF IOL implantation formed group 2 (n=15. Best-corrected visual acuity (BCVA with Snellen chart, biomicroscopic examination, intraocular pressure (IOP measurement with applanation tonometer, gonioscopy performed by Goldmann’s 3-mirror contact lens, and fundus examination were performed preoperatively in all patients. Results: There was no statistically significant difference in postoperative BCVA (p=0.492 and postoperative success (BCVA not changed or better postoperatively between the 2 groups (p=0.598. Postoperative success rate was 80% in group 1 and 93.7% in Group 2. The postoperative cylindrical power of the eyes did not differ significantly between the groups (p=0.220. The postoperative complications in group 1 were as follows: transient corneal edema in 5 eyes, transient IOP elevation in 2 eyes, postoperative fibrinous reaction in the anterior chamber in one eye, late-onset secondary glaucoma in one eye, hyphema in one eye, cystoid macular edema in one eye, vitreous prolapse into the anterior chamber in one eye, and IOL malposition in one eye. The postoperative complications in group 2 were as follows: transient corneal edema in 3 eyes, vitreous prolapse into the anterior chamber in 2 eyes, IOL malposition in 2 eyes, transient IOP elevation in one eye, and retinal detachment in one eye. Conclusion: In this study, both IOL types were observed to be preferable in cases without adequate capsular support following complicated cataract surgery. However, further studies with large numbers of patients are needed to define the best choice

  9. Clinical observation of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract in the sight restoration project

    Directory of Open Access Journals (Sweden)

    Xiao-Jian Cheng

    2014-04-01

    Full Text Available AIM: To analyze the clinical effects of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract.METHODS:Totally 642 cases 676 eyes of cataract were treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Complication during and after operations and postoperative visual acuity was observed.RESULTS:Visual acuity of 670 eyes was ≥0.05 and off-blindness rate was 99.11%, and there was 627 eyes ≥0.3 and the off-disability rate was 92.75% after 1mo. Rupture of posterior capsule during surgery occurred in 24 eyes. Fifty-four eyes were corneal edema, and anterior chamber exudation were 26 eyes, and 23 eyes were hypertension after operation. CONCLUSION: There are a little complications during and after operation for cataract treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Patients have good recovery after operation. This operation does not need high-standard equipments and is suitable in the sight restoration project.

  10. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty

    Directory of Open Access Journals (Sweden)

    Andleeb Zafar

    2018-02-01

    Full Text Available Purpose: We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods: The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK, and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results: Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion: A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  11. Changes in corneal endothelium cell characteristics after cataract surgery with and without use of viscoelastic substances during intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Schulze SD

    2015-11-01

    Full Text Available Stephan D Schulze,1 Thomas Bertelmann,1 Irena Manojlovic,2 Stefan Bodanowitz,2 Sebastian Irle,3 Walter Sekundo11Department of Ophthalmology, Philipps University of Marburg, Marburg, 2Private Practice and Ambulatory Surgical Center, Bremen, 3Freelance Statistician, Friedberg, GermanyPurpose: To evaluate whether the use of balanced salt solution (BSS or an ophthalmic viscoelastic device (OVD during hydrophilic acrylic intraocular lens (IOL implantation variously impacts corneal endothelial cell characteristics in eyes undergoing uneventful phacoemulsifications.Methods: Prospective nonrandomized observational clinical trial. Patients were assigned either to the BSS plus® or to the OVD Z-Celcoat™ group depending on the substance used during IOL implantation. Corneal endothelium cell characteristics were obtained before, 1 week, and 6 weeks after surgery. Intraoperative parameters (eg, surgery time, phacoemulsification energy were recorded.Results: Ninety-seven eyes were assigned to the BSS plus and 86 eyes to the Z-Celcoat group. Preoperative corneal endothelium cell density (ECD and endothelium cell size were 2,506±310 cells/mm2/2,433±261 cells/mm2 and 406±47 µm2/416±50 µm2 (P=0.107/P=0.09. After 1 and 6 weeks, ECD decreased and endothelium cell size increased significantly in both groups (each P<0.001 without significant differences between both groups (each P>0.05. Irrigation–aspiration suction time (30.3±16.6 versus 36.3±14.5 seconds and overall surgical time (7.2±1.2 versus 8.0±1.4 minutes were significantly longer in the OVD Z-Celcoat group (each P<0.001. No complications or serious side effects occurred.Conclusion: Implantation of a hydrophilic acrylic IOL under BSS infusion seems to be a useful and faster alternative in experienced hands without generating higher ECD loss rates.Keywords: phacoemulsification, ophthalmic viscoelastic device, endothelial cell density, IOL

  12. [Visual rehabilitation of patients with large post-traumatic defects of the anterior eye segment through iris-lens diaphragm implantation].

    Science.gov (United States)

    Khodzhaev, N S; Sobolev, N P; Mushkova, I A; Izmaylova, S B; Karimova, A N

    The diversity of methodological approaches and lack of pathogenetically reasonable tactics for patients with combined ocular injuries became the basis for the development and systematization of surgical rehabilitation stages of patients, in whom post-traumatic cataract is combined with post-traumatic aniridia and corneal scarring. to construct a visual rehabilitation approach to patients with post-traumatic defects of the anterior eye segment following optical-reconstructive surgery that involved implantation of an iris-lens diaphragm (ILD). We have analyzed 80 reconstructive cases with ILD implantation in patients with post-traumatic aniridia and corneal damage. These patients constituted the first study group (Group 1). We have also investigated 58 eyes with residual ametropy and stable visual function 1 year after ILD implantation before and after conducting a laser keratorefractive surgery. These patients were assigned to the second study group (Group 2). Rehabilitation approach to patients after anterior segment injuries that has been proposed allows to achieve high clinical and functional results and reduce the risk of intra- and postoperative complications. The proposed approach to patients after optical-reconstructive surgery with iris-lens diaphragm implantation followed by keratorefractive surgery is an effective method of visual rehabilitation of anterior eye segment post-traumatic defects.

  13. Safety and effect of femtosecond laser-assisted cataract surgery combined with Cionni capsular tension ring implantation in the management of traumatic lens subluxation

    Directory of Open Access Journals (Sweden)

    Jia-Hui Chen

    2017-07-01

    Full Text Available AIM:To investigate the safety and effect of femtosecond laser-assisted cataract surgery with Cionni modified capsular tension ring(MCTRimplantation in the management of traumatic lens subluxation.METHODS: Totally 11 patients(11 eyeswith traumatic lens subluxation were divided into three groups according to the severity of lens dislocation, ranging from 90° to 120°(4 eyes, 120° to 180°(5 eyesand 180° to 270°(2 eyes. The contact LenSx femtosecond laser cataract surgery platform was applied to create the capsulotomy, prepare nuclear fragmentation and make corneal wound creation. Anterior vitrectomy was performed in some patients during the surgery. After capsular retractors insertion and phacoemulsification, the MCTR was inserted to the capsular bag and fixed to the sclera. Finally, the IOL was implanted into the capsular bag. Postoperative visual acuity, intra- and post-operative complications, anterior capsular opening, IOL and MCTR position and intraocular pressure(IOPwere assessed.RESULTS:The duration of follow-up was 2mo. All the operations were completed successfully. Five eyes underwent cataract surgery combined with anterior vitrectomy. Four eyes had been inserted with 2-eyelet MCTR and seven eyes with 1-eyelet MCTR. The best corrected visual acuity(BCVAafter operation was better than 0.5 in 4 eyes, between 0.3 and 0.5 in 3 eyes, between 0.1 and 0.3 in 3 eyes, and less than 0.1 in 1 eye. Compared with preoperative BCVA, the difference was statistically significant(PCONCLUSION:Femtosecond laser-assisted cataract surgery can improve the success rate of capsulorhexis, and reduce the difficulty of nuclear fragmentation. Femtosecond laser-assisted cataract surgery combined with MCTR implantation is an ideal surgical method for traumatic lens subluxation.

  14. Desempenho visual após implante de uma lente intraocular asférica multifocal difrativa Visual performance after implantation of an aspheric multifocal diffractive intraocular lens

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2010-08-01

    Full Text Available OBJETIVO: Avaliar a acuidade visual a distancia, intermediária e perto após o implante de uma lente intraocular (LIO asférica multifocal difrativa AcrySof® ReSTOR® SN6AD1. MÉTODOS: Estudo prospectivo de 50 pacientes com catarata submetidos à facoemulsificação e implante de LIO AcrySof® ReSTOR®. Foram avaliados acuidade visual sem correção (AVSC, acuidade visual com correção (AVCC para longe, acuidade visual para perto corrigida para longe (AVPC e acuidade visual intermediária corrigida para longe (AVIC. Um questionário de satisfação e fenômenos visuais foi administrado ao final do estudo. RESULTADO: Após três meses de cirurgia, a média das acuidades (logMAR era: AVSC, 0,05 ± 0,07; AVCC, 0,00 ± 0,01; AVPC, 0,00 ± 0,0, e AVIC, 0,15 ± 0,05. A AVCC e AVPC era de 20/25 ou melhor em todos os pacientes, sendo a AVIC J3 ou melhor em 83% dos pacientes. Pacientes relataram excelente desempenho visual nas questões relacionadas a atividades para distância, intermediário, e perto com pouca ou nenhuma dificuldade. Nenhum paciente relatou halos ou 'glare' severos, sendo os mesmos caracterizados entre nenhum a moderado. CONCLUSÃO: A LIO asférica AcrySof® ReSTOR® SN6AD1 mostrou excelentes resultados na visão para longe, perto e intermediário, além de apresentar uma baixa incidência de fenômenos visuais.PURPOSE: To evaluate distance, intermediate, and near vision after aspheric multifocal diffractive AcrySof® ReSTOR® SN6AD1 intraocular lens (IOL implantation. METHODS: Prospective study of 50 patients with cataract that had phacoemulsification and AcrySof® ReSTOR® IOL implantation. Uncorrected distance vision acuity (UDVA, corrected distance visual acuity (CDVA, distance-corrected near visual acuity (DCNVA, and distance-corrected intermediate visual acuity (DCIVA were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered at the end of the study. RESULTS: Three months

  15. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  16. Molecular characterization and potential sources of aqueous humor bacterial contamination during phacoemulsification with intraocular lens implantation in dogs.

    Science.gov (United States)

    Lacerda, Luciana C C; de Souza-Pollo, Andressa; Padua, Ivan Ricardo M; Conceição, Luciano F; da Silveira, Camila P Balthazar; Silva, Germana A; Maluta, Renato P; Laus, José L

    2018-01-01

    Bacterial contamination of the anterior chamber during cataract surgery is one of the main responsible for endophthalmitis postoperative. Phacoemulsification is a less invasive technique for cataract treatment, although it does not exclude the possibility of contamination. In this study, bacterial contaminants of aqueous humor collected pre- and post-phacoemulsification with intraocular lens implantation (IOL) of twenty dogs were identified. As the conjunctival microbiota constitute a significant source of anterior chamber contamination, bacterial isolates from aqueous humor were genetically compared with those present in the conjunctival surface of the patients. Three dogs presented bacterial growth in both aqueous humor and conjunctival surface samples. Bacterial isolates from these samples were grouped according to their genetic profiles by repetitive-element PCR (rep-PCR) and their representatives were identified by 16S rRNA sequencing. Isolates from conjunctival surface were identified as Enterobacter spp., Staphylococcus spp. and S. aureus; and from aqueous humor samples as Enterobacter spp., Pantoea spp., Streptococcus spp. and Staphylococcus spp., respectively in decreasing order of prevalence. According to the rep-PCR analysis, 16.6% of Enterobacter spp. isolates from conjunctival surface were genetically similar to those from aqueous humor. The rest of isolates encountered in aqueous humor were genetically distinct from those of conjunctival surface. The significant genetic diversity of bacterial isolates found in the aqueous humor samples after surgery denoted the possibility of anterior chamber contamination during phacoemulsification by bacteria not only from conjunctival surface but also from different sources related to surgical environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Visual outcome and changes in corneal endothelial cell density following aphakic iris-fixated intraocular lens implantation in pediatric eyes with subluxated lenses.

    Science.gov (United States)

    Siddiqui, Sorath Noorani; Khan, Ayesha

    2013-01-01

    To evaluate the visual outcome and corneal endothelial cell density after Artisan aphakic intraocular lens (IOL) implantation (Ophtec, Groningen, the Netherlands) in pediatric eyes with subluxated lenses. Artisan aphakic IOLs were implanted in 18 eyes of 11 children with subluxated lenses. Idiopathic subluxations and ectopia lentis due to Marfan syndrome were included, whereas subluxations due to trauma or buphthalmos were excluded. Best-corrected visual acuity (BCVA) and endothelial cell density were monitored. Mean postoperative BCVA and endothelial cell density at last follow-up visit were calculated. The age of children at the time of Artisan aphakic IOL implantation ranged from 8 to 16 years (mean: 11.58 ± 2.9 years). Mean follow-up was 9.12 ± 4.30 months. Mean postoperative logarithm of the minimum angle of resolution BCVA was 0.26 ± 0.13 (P = .001) and mean postoperative endothelial cell density was 2,860 ± 435 cells/mm(2) (P = .000). Mean endothelial cell loss was 17.1%. Artisan aphakic IOL implantation is a safe surgical choice in the management of ectopia lentis in the pediatric age group. It has minimal complications and is less traumatic to pediatric eyes. However, long-term follow-up of these children is required.[J Pediatr Ophthalmol Strabismus 2013;50(3):178-182.]. Copyright 2013, SLACK Incorporated.

  18. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Azuara-Blanco, Augusto; Burr, Jennifer M; Cochran, Claire; Ramsay, Craig; Vale, Luke; Foster, Paul; Friedman, David; Quayyum, Zahidul; Lai, Jimmy; Nolan, Winnie; Aung, Tin; Chew, Paul; McPherson, Gladys; McDonald, Alison; Norrie, John

    2011-05-23

    Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of

  19. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Chew Paul

    2011-05-01

    Full Text Available Abstract Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle and medical treatment (to reduce intraocular pressure. If these treatments fail, glaucoma surgery (eg, trabeculectomy is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy, costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat. 400 participants (200 in each group will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05

  20. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes

    NARCIS (Netherlands)

    Nuijts, Rudy M. M. A.; Jonker, Soraya M. R.; Kaufer, Robert A.; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-01-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8

  1. Phakic Intraocular Lens Implantation: Refractive Outcome and Safety in Patients with Anterior Chamber Depth between 2.8 and 3.0 versus ≥3.0 mm.

    Science.gov (United States)

    Guerra, Marta G; Silva, Andreia M M; Marques, Sara H M; Melo, Sofia H; Póvoa, João A; Lobo, Conceição; Murta, Joaquim Neto

    2017-01-01

    To compare endothelial cell (EC) variation after anterior chamber phakic intraocular lens (AC-pIOL) implantation in highly myopic patients with a preoperative anterior chamber depth (ACD) between 2.8 and 3.0 versus ≥3.0 mm. A total of 280 eyes submitted to primary AC-pIOL implantation were analyzed. Pre- and postoperative values for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, ACD (endothelial surface), and EC count were collected. The eyes were divided into 2 groups: group A - ACD between 2.8 and 3.0 mm; group B - ACD ≥3.0 mm. Mean global EC loss (ECL) and loss for each ACD group, according to pIOL type, were analyzed. Significant improvement of the spherical equivalent (-11.38 ± 4.57 vs. -0.49 ± 0.79; p = 0.000) and a significant decrease in EC density (2,810.95 ± 343.88 vs. 2,584.09 ± 374.88 cells/mm2; p = 0.000) were noted. The mean annual ECL was -2.19 ± 3.97%. Regarding group A (n = 80), a mean annual ECL of -2.06 ± 3.88% was registered, higher for the Acrysof Cachet® subtype, while group B (n = 200) showed -2.25 ± 4.01% ECL, higher for the Verisyse® subtype. There was no significant difference between the groups (p = 0.96). AC-pIOL implantation significantly improves the spherical equivalent in myopic patients. The mean annual ECL after pIOL implantation was higher in the larger ACD group, but this value was not statistically significant. A 2.8-mm ACD value seems to be a safe cutoff for AC-pIOL implantation. © 2017 S. Karger AG, Basel.

  2. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

    Science.gov (United States)

    Ouchi, M; Kinoshita, S

    2015-05-01

    To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.

  3. Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-08-01

    Full Text Available Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions – with the consequent need for cross-linking – intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.

  4. Corneal Collagen Cross-Linking Combined with an Artiflex Iris-Fixated Anterior Chamber Phakic Intraocular Lens Implantation in a Patient with Progressive Keratoconus

    Directory of Open Access Journals (Sweden)

    Sharif Hashmani

    2017-10-01

    Full Text Available We present here the case of a 24-year-old male who experienced progressive keratoconus and vision loss which adversely affected his ability to carry out everyday tasks. This landed him in the Hashmanis Hospital for consultation. He had a preoperative best corrected visual acuity of 6/12. He underwent multiple Oculus Pentacam examinations, which showed progressive keratoconus. Corneal collagen cross-linking (CXL was performed to stabilize his cornea and, subsequently, an Artiflex anterior chamber iris-fixated phakic intraocular lens (ACIF-PIOL was implanted to alleviate his refractive errors. The patient achieved a postoperative uncorrected visual acuity of 6/12. This report shows that CXL combined with ACIF-PIOL can be safe and effective in those with progressive keratoconus.

  5. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    Science.gov (United States)

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  6. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes.

    Science.gov (United States)

    Nuijts, Rudy M M A; Jonker, Soraya M R; Kaufer, Robert A; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-02-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8 investigative sites. Prospective randomized parallel-group patient-masked 2-arm study. This study comprised adults requiring bilateral cataract extraction followed by multifocal IOL implantation. The primary endpoint was corrected intermediate visual acuity (CIVA) at 60 cm, and the secondary endpoint was corrected near visual acuity (CNVA) at 40 cm. Both endpoints were measured 3 months after implantation with a noninferiority margin of Δ = 0.1 logMAR. In total, 103 patients completed the study (53 bilateral, 50 contralateral). At 3 months, the mean CIVA at 60 cm was 0.13 logMAR and 0.10 logMAR in the bilateral group and contralateral group, respectively (difference 0.04 logMAR), achieving noninferiority. Noninferiority was not attained for CNVA at 40 cm; mean values at 3 months for bilateral and contralateral implantation were 0.26 logMAR and 0.11 logMAR, respectively (difference 0.15 logMAR). Binocular defocus curves suggested similar performance in distance vision between the 2 groups. Treatment-emergent ocular adverse events rates were similar between the groups. Bilateral implantation of the +2.5 D multifocal IOL resulted in similar distance as contralateral implantation of the +2.5 D multifocal IOL and +3.0 D multifocal IOL for intermediate vision (60 cm), while noninferiority was not achieved for near distances (40 cm). Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Clinical and patient-reported outcomes of bilateral implantation of a +2.5 diopter multifocal intraocular lens.

    Science.gov (United States)

    Maxwell, Andrew; Holland, Edward; Cibik, Lisa; Fakadej, Anna; Foster, Gary; Grosinger, Les; Moyes, Andrew; Nielsen, Stephen; Silverstein, Steven; Toyos, Melissa; Weinstein, Arthur; Hartzell, Scott

    2017-01-01

    To assess the effectiveness and safety of a multifocal intraocular lens (IOL) with +2.5 diopter (D) additional power compared with a monofocal IOL. Fifteen sites in the United States. Prospective randomized patient- and observer-masked clinical trial. Randomized patients received multifocal or monofocal IOLs bilaterally. Visual acuity (33 cm, 40 cm, 53 cm, 60 cm, 4 m) was measured; safety was assessed through adverse event rates. Patient-reported visual outcomes were evaluated using the Visual Tasks questionnaire. The frequency and severity of visual disturbances were evaluated using the Assessment of Photic Phenomena and Lens EffectS questionnaire. The multifocal IOL (n = 155) provided better corrected distance visual acuity at 53 cm than the monofocal IOL (n = 165) (0.322 versus 0.512 logMAR; between-group difference, -0.190 logMAR; P < .0001) and 40 cm but not at 4 m. Ocular adverse event rates were less than 3.84% in both groups. Serious adverse event rates were comparable between the 2 IOL types. Patients with multifocal IOLs reported less difficulty with near tasks (with and without correction) and intermediate tasks (without correction). Difficulty with extended-intermediate and distance tasks was similar between groups. The most frequently reported self-rated severe phenomena were halos, starbursts, and glare. Most patients (monofocal ≥72%; multifocal ≥73%) reported never experiencing blurred, distorted, or double vision. The +2.5 D multifocal IOL provided better vision at 40 cm and 53 cm and similar vision at 4 m compared with the monofocal IOL. Safety profiles and visual phenomena were comparable between groups. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Implantação de lente intraocular com uma alça amputada: proposta para o tratamento cirúrgico da subluxação do cristalino Intraocular lens implantation with one loop haptic amputed: a new propose to the subluxation lens surgical treatment

    Directory of Open Access Journals (Sweden)

    Marcelo Ventura

    2010-04-01

    Full Text Available OBJETIVO: Avaliar os resultados pós-operatórios da subluxação congênita do cristalino, corrigida por uma nova abordagem cirúrgica. MÉTODOS: Foram estudados 21 olhos de 13 pacientes, portadores de subluxação não traumática do cristalino submetidos à cirurgia na Fundação Altino Ventura, no período de abril de 1999 a abril de 2004. A idade média foi de 8,7 ± 5,4 anos, e o tempo médio de seguimento foi 21,5 ± 19,3 meses. Os pacientes foram submetidos à facoaspiração, implante do anel endocapsular e lente intraocular (LIO. Uma das alças da LIO foi amputada e apoiada sobre o anel, no interior do saco capsular, centralizando a LIO. RESULTADOS: Houve melhora da acuidade visual (AV em todos os casos, e redução significante do equivalente esférico e componente esférico comparando-se a refração pré e pós-operatória (pPURPOSE: To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. METHODS: Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 ± 5.4 years old, and the mean follow-up period was 21.5 ± 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. RESULTS: Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (p<0.01. There was no statistically significant difference between the pre and postoperative cylinder component (p=0.71. Posterior capsule opacification was a postoperative complication found in 71.4% of the cases. Early posterior capsulotomy was performed with no complications in these cases. CONCLUSION

  9. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    Science.gov (United States)

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  10. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  11. Implantation of a multifocal toric intraocular lens with a surface-embedded near segment after repeated LASIK treatments.

    Science.gov (United States)

    Khoramnia, Ramin; Auffarth, Gerd U; Rabsilber, Tanja M; Holzer, Mike P

    2012-11-01

    We report a 66-year-old patient who presented with increasing hyperopia, astigmatism, and presbyopia in both eyes 8 years after bilateral laser in situ keratomileusis (LASIK) and LASIK enhancement in the left eye aiming for spectacle independence. Bilateral multifocal toric Lentis Mplus intraocular lenses (IOLs) with an embedded near segment and individually customized cylinder correction were implanted uneventfully following phacoemulsification. The Haigis-L formula after previous hyperopia correction was chosen for IOL power calculation and provided reliable results. Emmetropia was targeted and achieved. Three months postoperatively, the uncorrected distance visual acuity had increased from 0.40 logMAR to 0.10 logMAR in the right eye and from 0.20 logMAR to 0.00 logMAR in the left eye. The patient gained 6 lines of uncorrected near visual acuity: 0.20 logMAR in the right eye and 0.10 logMAR in the left eye. This case shows that customized premium IOL implantation can provide accurate results even in challenging cases. The International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany, has received research grants, lecture fees, and travel reimbursement from Oculentis GmbH. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Patients with Fuchs Endothelial Dystrophy and Cataract Undergoing Descemet Stripping Automated Endothelial Keratoplasty and Phacoemulsification with Intraocular Lens Implant: Staged versus Combined Procedure Outcomes.

    Science.gov (United States)

    Sykakis, Evripidis; Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian

    2015-01-01

    Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods.

  13. Patients with Fuchs Endothelial Dystrophy and Cataract Undergoing Descemet Stripping Automated Endothelial Keratoplasty and Phacoemulsification with Intraocular Lens Implant: Staged versus Combined Procedure Outcomes

    Directory of Open Access Journals (Sweden)

    Evripidis Sykakis

    2015-01-01

    Full Text Available Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL and Descemet stripping automated endothelial keratoplasty (DSAEK in patients with Fuchs’ endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1 or phaco+IOL followed within 2 months by DSAEK (group 2. Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% P=0.04, while the endothelial cell density at 12 months was 1510±433 for group 1 and 1535±482 for group 2 P=0.89. The mean 12-month logMAR visual acuity was 0.28±0.24 for group 1 and 0.33±0.15 for group 2 P=0.38. Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods.

  14. Facoemulsificação, vitrectomia via pars plana e implante de lente intra-ocular em olhos com retinopatia diabética proliferativa Phacoemulsification, pars plana vitrectomy and intraocular lens implant in eyes with proliferative diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Armando Belfort Mattos

    2004-06-01

    realizar a vitrectomia via pars plana, ao invés de se realizar uma segunda cirurgia, que seria somente para a remoção da catarata após a vitrectomia pars plana, é técnica segura e capaz de promover a melhora da acuidade visual além de ser menos agressiva para o paciente. O potencial para melhora da acuidade visual final é limitado pela gravidade da retinopatia diabética.PURPOSE: To evaluate the outcomes and the best technique for a combined phacoemulsification (PHACO, pars plana vitrectomy (PPV and posterior chamber intraocular lens insertion (PCIOL in one single procedure for patients with proliferative diabetic retinopathy. METHODS: We reviewed charts of 47 (53 eyes patients with proliferative diabetic retinopathy who underwent combined phacoemulsification with posterior chamber intraocular lens implant and pars plana vitrectomy performed between January 1991 and September 1998 at the Bascom Palmer Eye Institute, eye hospital affiliated with the University of Miami. The study was done in conjunction with the Federal University of São Paulo. A total of 43 eyes from 40 patients were elected to participate in the study. RESULTS: The follow-up range was three to 60 months (mean 20 months. The age ranged from 37 to 77 years with a mean of 59. Preoperative visual acuity improved two lines or more in 26 (60.4% eyes, remained the same in 9 (20.9% and got worse in 8 (18.6%. In 10 (23.2% eyes visual acuity improved to 20/40. The study showed to be statistically significant for the improvement of the final visual acuity. Recurrent vitreous hemorrhage was the most frequent postoperative complication found in 12 (27.9% eyes and it was followed by transient anterior chamber reaction in 9 (20.9% eyes. Intraoperative and postoperative complications related to phacoemulsification were rare. IOL capture was found in 2 (4.6% eyes and intraocular lens subluxation in 1 (2.3% eye. CONCLUSION: Combined phacoemulsification with posterior chamber intraocular lens implant and pars plana

  15. The Effects of Phacoemulsification and Intraocular Lens Implantation on Anatomical and Functional Parameters in Patients with Primary Angle Closure: A Prospective Study. (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Traverso, Carlo Enrico; Cutolo, Carlo Alberto

    2017-08-01

    To investigate the clinical, anatomical, and patient-reported outcomes of phacoemulsification (PE) with intraocular lens implantation performed to treat primary angle closure (PAC) and primary angle-closure glaucoma (PACG). Patients were evaluated at baseline and at 6 months after PE. The examination included visual acuity, intraocular pressure (IOP), visual field, optic nerve head, endothelial cell count (ECC), aqueous depth, and ocular biometric parameters. Patient-reported visual function and health status were assessed. Coprimary outcome measures were IOP changes, angle widening, and patient-reported visual function; secondary outcome measures were visual acuity changes, use of IOP-lowering medications, and complications. Univariate and multivariate analyses were performed to determine the predictors of IOP change. Thirty-nine cases were identified, and postoperative data were analyzed for 59 eyes, 39 with PACG and 20 with PAC. Globally, PE resulted in a mean reduction in IOP of -6.33 mm Hg (95% CI, -8.64 to -4.01, P <.001). Aqueous depth and angle measurements improved ( P <.01), whereas ECC significantly decreased ( P <.001). Both corrected and uncorrected visual acuity improved ( P <.01). The EQ visual analog scale did not change ( P =.16), but VFQ-25 improved ( P <.01). The IOP-lowering effect of PE was greater in the PACG compared to the PAC group ( P =.04). In both groups, preoperative IOP was the most significant predictor of IOP change ( P <.01). No sight-threatening complications were recorded. Our data support the usefulness of PE in lowering the IOP in patients with PAC and PACG. Although PE resulted in several anatomical and patient-reported visual improvements, we observe that a marked decrease in ECC should be carefully weighed before surgery.

  16. Resultados preliminares do implante de lente intra-ocular fácica artisan para correção de miopia Preliminary results of artisan phakic intraocular lens implantation to correct myopia

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2007-06-01

    Artisan anterior chamber intra-ocular lens for the correction of myopia in the first 6 months. METHODS: A retrospective study of 18 patients (34 eyes that received the implantation of Artisan anterior chamber intraocular lens for the correction of myopia was conducted. Best visual preoperative acuity, best visual postoperative acuity, dynamic preoperative and postoperative refraction, loss and improvement of lines of vision and complications were evaluated. RESULTS: Eighteen patients (34 eyes were included in this study. Fourteen patients were females (77.8% and 4 were males. The mean age was 30 years (SD ± 7.3, range from 21 to 46 years. They were followed up for an average of 8.5 months (SD ± 3.6. The mean endothelial cell loss was 4.75% at 6 months follow-up. The average preoperative uncorrected visual acuity was 0.02 (20/800 range from 0.01 to 0.13. The average preoperative spherical equivalent was -13.25 D, range from -5.75 D to -19,75 D. On the last follow-up, uncorrected visual acuity was 0.64 (20/32, range from 0.33 to 1.00; the average spherical equivalent was -1.18 D (DP ± 0.92 range from +0.25 to -3.0. Complications were observed in 1 case (3.4% of our study, in one patient who had a dislocation of the lens after an ocular trauma. CONCLUSION: The use of Artisan anterior chamber intraocular lens in phakic eyes for the correction of myopia was safe, effective and predictable. However, a larger prospective study with a higher number of cases and longer follow-up is necessary to determine long-term safety of the lens.

  17. Implante intra-ocular de lentes dobráveis "piggyback" em paciente portador de catarata congênita no primeiro ano de vida: relato de caso Piggyback foldable intraocular lens implant in patient with congenital cataract in the first year of life: case report

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2004-12-01

    Full Text Available No presente relato os autores descrevem um caso de catarata congênita unilateral tratada cirurgicamente com implante intra-ocular de lentes dobráveis "piggyback", ainda não descrito na literatura nacional. São analisadas as diferenças e semelhanças com outros casos descritos na literatura.The authors report a case of congenital cataract, which was treated with piggyback foldable intraocular lens implant, not described in the Brazilian literature. The differences and similarities are analyzed with other reported cases in the literature.

  18. Qualidade de vida de pacientes pseudofácicos submetidos à cirurgia de catarata com implante de lente intra-ocular acomodativa Quality of life of pseudophakic patients with accommodative intraocular lens implant

    Directory of Open Access Journals (Sweden)

    Filipe de Oliveira

    2004-06-01

    Full Text Available OBJETIVO: Avaliar a função visual e satisfação dos pacientes submetidos à cirurgia de catarata com implante de lente intra-ocular acomodativa e o impacto na sua qualidade de vida. MÉTODOS: Retrospectivamente, foram avaliados questionários aplicados após um ano da cirurgia de 22 pacientes que foram incluídos num estudo clínico para avaliar segurança e eficácia de uma lente intra-ocular de silicone de câmara posterior designada para corrigir visão para longe e perto. RESULTADOS: Do total dos pacientes operados, 16 (73% eram bilaterais e 6 (27% unilaterais, com idade média de 70,2 anos. Dos pacientes com implante unilateral, 5 (83,3% declararam melhora acentuada da visão e 1 (16,7% referiu máxima melhora. Quanto ao nível de satisfação, 5 (83,3% ficaram satisfeitos e 1 (16,7% muito satisfeito com o resultado cirúrgico. A visão noturna foi declarada como sem dificuldade por 3 (50,0%, pouca dificuldade por 2 (33,3% e dificuldade moderada por 1 (16,7%. No grupo bilateral, 7 (43,8% consideraram excelente a qualidade da visão para perto, 7 (43,8% muito boa, 1 (6,2% adequada e 1 (6,2% ruim. A visão intermediária foi classificada como excelente por 6 (37,5%, muito boa por 9 (56,3% e adequada por 1 (6,2%. A qualidade da visão para longe foi considerada excelente por 9 (56,3%, muito boa por 3 (43,8%, adequada por 2 (12,5% e não muito boa por 2 (12,5%. Em relação à visão noturna 9 (56,3% declararam não ter dificuldade alguma, 5 (31,2% pouca dificuldade e 2 (12,5% dificuldade moderada. CONCLUSÕES: Considerando a propriedade óptica da LIO, a maioria dos pacientes apresentou uma melhora considerável da função visual, sem a necessidade de correção óptica, e, portanto, com impacto positivo na qualidade de vida.PURPOSE: To evaluate the visual function and satisfaction of patients who underwent cataract surgery and were implanted with an accommodative intraocular lens and the impact in their quality of life. METHODS

  19. Observations on the relationship between the levels of serum IL-6 and TNF-α and the severity of diabetic retinopathy and curative effect in cataract extraction with intraocular lens implantation in diabetics

    International Nuclear Information System (INIS)

    Wang Yumin; Ma Xinying; Song Yuebing; Liang Yong; Zhang Xiaoguang

    2001-01-01

    Objective: To determine the sequential changes of blood levels of interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) in diabetics with extracapsular extraction and posterior chamber intraocular lens implantation and to study their correlation with curative effects and pos-operative complications. Methods: The serum concentrations of IL-6 and TNF-α in 39 diabetics and non-diabetics were measured by radioimmunoassay at preoperative, post-operative and on days 7, 14 and 90 postoperatively. Results: There was significant difference in the levels of the two factors between the diabetic group and non-diabetic group preoperatively (P<0.05). The serum levels of the two factors in patients with proliferative diabetic retinopathy were higher than those in non-diabetic retinopathy, and simple diabetic retinopathy post-operative (P<0.01). Post-operative complication rate was higher in patients with proliferative diabetic retinopathy than those without retinopathy and those having simple diabetic retinopathy. Conclusion: The levels of the two factors correlate with complications and curative effect of patients with proliferative diabetic retinopathy undergoing intraocular lens implantation

  20. Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics.

    Science.gov (United States)

    Kawamorita, Takushi; Shimizu, Kimiya; Shoji, Nobuyuki

    2016-04-01

    A modified implantable collamer lens (ICL) with a central hole with a diameter of 0.36 mm, referred to as a hole-ICL, was created to improve aqueous humour circulation. The aim of this study is to investigate the ideal hole size in a hole-ICL from the standpoint of the fluid dynamic characteristics of the aqueous humour using computational fluid dynamics. Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V 12.2 (Mentor Graphics Corp.). In the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with a conventional ICL (Model ICM, Staar Surgical) and a hole-ICL were used. The hole-ICL was -9.0 dioptres (D) and 12.0 mm in length, with an optic zone of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μL/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was calculated, and trajectory analysis was performed. With an increase in the central hole size, the velocity of the aqueous humour increased, with the peak velocity occurring at a diameter of approximately 0.4 mm. Once the diameter had increased above 0.4 mm, the velocity then decreased. The velocity difference between the cases of a central hole size of 0.1 mm and 0.2 mm was significant. The desirable central hole size was 0.2 mm or larger in terms of flow dynamics. The current model, based on a central hole size of 0.36 mm, was close to ideal. The optimisation of the hole size should be performed based on results from a long-term clinical study so as to analyse the incidence rate of secondary cataract and optical performance.

  1. Development of an accommodating intra-ocular lens - In vitro prevention of re-growth of pig and rabbit lens capsule epithelial cells

    NARCIS (Netherlands)

    van Kooten, Theo G.; Koopmans, Steven; Terwee, Thom; Norrby, Sverker; Hooymans, J. M. M.; Busscher, Henk J.

    2006-01-01

    Cataract surgery is routinely performed to replace the clouded lens by a rigid polymeric intra-ocular lens unable to accommodate. By implanting a silicone gel into an intact capsular bag the accommodating properties of the natural lens can be maintained or enhanced. The implantation success of

  2. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  3. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  4. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil...

  5. Surgical effect of traumatic lens dislocation with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Dan Zhang

    2014-10-01

    Full Text Available AIM: To retrospectively evaluate the effect of lens extraction combined with vitrectomy to treat traumatic lens dislocation with secondary glaucoma.METHODS:Thirty-one eyes(31 casesof lens dislocation caused by blunt trauma with secondary glaucoma were treated respectively with cataract extraction combined with anterior vitrectomy, trabeculectomy and intraocular lens implantation. The visual acuity and pressure were observed 1wk, 1 and 3mo after operative. RESULTS:Thirty-one eyes were all complete the operation successfully, and 6 eyes were given combined trabeculectomy, 9 eyes were implanted anterior chamber intraocular lens implantation(IOLand 15 eyes were given posterior chamber suture fixation. Sixteen eyes were implanted in one-stage operation, while 8 eyes were implanted in two-stage operation. All intraocular pressure(IOPwere controlled to the normal level after operation and 23 eyes had visual acuity of more than 0.3.CONCLUSION:Lens extraction combined with vitrectomy is an effective method for treatment of lens dislocation with secondary glaucoma. In order to control the IOP and get well visual function, we should choose IOL implantation or trabeculectomy according to the patient's condition.

  6. [Management of post-traumatic aphakia and aniridia: Retrospective study of 17 patients undergoing scleral-sutured artificial iris intraocular lens implantation. Management of aphakia-aniridia with scleral-sutured artificial iris intraocular lenses].

    Science.gov (United States)

    Villemont, A-S; Kocaba, V; Janin-Manificat, H; Abouaf, L; Poli, M; Marty, A-S; Rabilloud, M; Fleury, J; Burillon, C

    2017-09-01

    To evaluate the long-term outcomes of artificial iris intraocular lenses sutured to the sclera for managing traumatic aphakia and aniridia. All consecutive cases receiving a Morcher ® combination implant from June 2008 to February 2016 in Edouard-Herriot Hospital (Lyon, France) were included in this single-center retrospective study. Visual acuity, subjective degree of glare, quality of life and surgical complications were evaluated. Seventeen eyes of 17 patients were included, among which 82% were male. The mean age was 42 years. The injuries consisted of 23.5% contusion and 70.5% open globe injuries, of which 41% were globe ruptures. There was one postoperative case. A penetrating keratoplasty was performed at the same time for eight eyes. The mean follow-up was 32 months. Best-corrected visual acuity improved in 41.2%, remained the same in 17.6% and decreased in 41.2% of our cases. Distance vision averaged 1±0.25 line better and near vision 2.2±0.32 lines better when visual acuity was quantifiable before surgery. Glare improved in 80% of patients and remained stable in 20%, decreasing on average from 3.3/5 [min. 3-max. 4; SD: 0.48] before surgery to 1.9/5 [min. 0-max. 4; SD: 1.197] after surgery. Regarding the esthetic results, 78% of the patients declared themselves reasonably to very satisfied; 57% reported no limitation of activities of daily living, and 43% reported mild limitation. Ocular hypertension and glaucoma, found in 40% of eyes, were the main postoperative complications. Implantation of prosthetic iris device combined with an intraocular lens appears to be safe and effective in reducing glare disability and improving visual acuity. Close, long-term monitoring is essential for the success of this surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312

  8. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Vrijman, V.; El-Saady, R.; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2014-01-01

    PURPOSE: To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). METHODS: This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric

  9. Effect of Timing of Initial Cataract Surgery, Compliance to Amblyopia Therapy on Outcomes of Secondary Intraocular Lens Implantation in Chinese Children: A Retrospective Case Series

    Directory of Open Access Journals (Sweden)

    Liuyang Li

    2018-01-01

    Full Text Available Purpose. As a secondary analysis, we reassess the association of initial congenital cataract surgery times, compliance to amblyopia therapy, and visual outcomes for a long-term follow-up in a secondary IOL implantation. Methods. Retrospective review of records of all infants with congenital cataracts who underwent secondary IOL implantation in the Eye and ENT Hospital of Fudan University from January 1, 2001, to December 31, 2007, and the minimum follow-up period was 5 years. Multiple regression analysis was used and the possible confounding factors were also analyzed to assess the effect on visual outcome. Results. A total of 110 patients (male: 59.1% were included. The median (min–max age at cataract extraction and IOL implantation was 7.5 (3.0–15.0 and 35.0 (22.0–184.0 months, respectively, and the average follow-up period was 99.3 ± 23.6 months. The median (min–max BCVA at final follow-up was 0.20 (0.01–1.00. Compliance to amblyopia therapy was none, poor, and good in 21.8%, 24.5%, and 53.6%, respectively. Postoperative BCVA [logMAR, median (min–max 0.70 (0.00–2.00] linearly decreased with increasing cataract extraction time (per month (β=0.04, 95% CI: 0.03–0.06, p<0.0001 in multivariable models with laterality and compliance to amblyopia therapy adjusted. Good compliance to amblyopia therapy was associated with better BCVA (logMAR at last follow-up (β=−0.40, 95% CI = −0.53 to −0.27, p<0.0001 with laterality, opacity type, and extraction time adjusted. Conclusions. For Chinese infants with congenital cataract, an earlier primary congenital cataract surgery at an age of 3 to 15 months is associated with a better visual outcome. Good compliance to amblyopia therapy was also significant to visual outcome.

  10. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  11. Method for producing an isoplanatic aspheric monofocal intraocular lens, and resul ting lens

    OpenAIRE

    Barbero, Sergio; Marcos, Susana; Dorronsoro, Carlos; Montejo, Javier; Salazar Salegui, Pedro

    2010-01-01

    [EN] The invention can be used to obtain isoplanatic aspheric mono focal intraocular lenses in a viewing range of up to 25° (preferably up to 10°). The method comprises the following steps: l. mathematical defmition of an aphakic eye model; 2. mathematical definition of an intraocular lens model; 3. mathematical defmition of the implantation of the lens; 4. mathematical defmition of the merit function; 5. definition of the contour conditions; 6. defmition of a measurement for charact...

  12. Two-Port Pars Plana Anterior and Central Core Vitrectomy (Lam Floaterectomy) in Combination With Phacoemulsification and Intraocular Lens Implantation Under Topical Anesthesia for Patients with Cataract and Significant Floaters: Results of the First 50 Consecutive Cases.

    Science.gov (United States)

    Lam, Dennis S C; Leung, Hiu Ying; Liu, Shu; Radke, Nishant; Yuan, Ye; Lee, Vincent Y W

    2017-01-01

    To study the safety and efficacy of 2-port pars plana anterior and central core vitrectomy (Lam floaterectomy) in combination with phacoemulsification (phaco) and intraocular lens implantation (IOL) for patients with cataract and significant floaters under topical anesthesia. Retrospective review of the first 50 consecutive cases. A standardized treatment protocol was used for patients with cataract and significant (moderate to severe) floaters (duration > 3 months). Data analysis included intraoperative and postoperative complications, floater status, and patient satisfaction. There were 50 eyes (38 patients) with a male-to-female ratio of 1 to 2.3. Twelve patients had bilateral eye surgeries. Mean age was 58.10 ± 9.85 years (range, 39-83). All patients completed the 3-month follow-up. One eye had mild vitreous hemorrhage at the end of surgery arising from sclerotomy wound oozing. No other intraoperative compli-cations were encountered. Postoperatively, there was 1 case of transient hypotony and 1 case of congestion at sclerotomy wound. No cases of retinal break or detachment, or clinically significant macular edema, were reported. There were 5 cases (10%) of mild residual floaters and 1 case (2%) of floater recurrence. Total floater clearance rate was 88%. Patient satisfaction rates were 80%, 14%, 6%, and 0% for very satisfied, satis-fied, acceptable, and unsatisfied, respectively. The 3-month results in terms of safety and efficacy of the Lam floaterectomy in combination with phaco and IOLfor patients with cataract and significant floaters under topical anesthesia are encouraging. Further larger-scale, prospective, multicenter studies seem warranted. Copyright© 2017 Asia-Pacific Academy of Ophthalmology.

  13. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  14. Converging or Diverging Lens?

    Science.gov (United States)

    Branca, Mario

    2013-01-01

    Why does a lens magnify? Why does it shrink objects? Why does this happen? The activities that we propose here are useful in helping us to understand how lenses work, and they show that the same lens can have different magnification capabilities. A converging lens can also act as a diverging lens. (Contains 4 figures.)

  15. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  16. Implante de lente intraocular en niños como solución a los problemas sociales de la ceguera por catarata congénita Intraocular lens implants for children as a solution to social problems caused by blindness from congenital cataract

    Directory of Open Access Journals (Sweden)

    Rosa María Naranjo Fernández

    2011-12-01

    congenital cataract ranges from 1 to 4 per 10 000 children in underdeveloped countries and 0,1 to 0,4 in industrialized countries. In Cuba, 2,1 million inhabitants are under 15 years of age and the congenital cataract is regarded as the second cause of infantile blindness. In the last 20 years, the surgical treatment of cataract in children has completely changed based on the remarkable improvement of the surgical techniques. In our country, the pediatric cataract surgery with intraocular lens implantation began in 1990 after the inauguration of the Ocular Microsurgery Center in 1988. The importance of this pediatric cataract surgery with intraocular lens implants was shown as a solution to the social problems caused by the visual deficit of inadequately treated patients, since the application of modern technology improves the quality of life of children both at social and educational level, and allows fully re-inserting them into the society.

  17. Incidência de opacificação de cápsula posterior em pacientes submetidos à facoemulsificação e implante de lentes intra-oculares acrílicas hidrofílicas expansíveis Incidence of posterior capsule opacification in patients submitted to phacoemulsification and expandable acrylic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Hilton Arcoverde Gonçalves de Medeiros

    2006-06-01

    Full Text Available OBJETIVO: Avaliar prospectivamente os resultados das lentes intra-oculares de polímeros expansíveis implantadas em pacientes submetidos à facoemulsificação, quanto à incidência de opacificação de cápsula posterior, levando em consideração a biocompatibilidade das lentes expansíveis. MÉTODOS: O grupo de estudo foi composto por 830 pacientes, 1.200 olhos, que foram submetidos a facoemulsificação, utilizando a mesma técnica, variando-se apenas o diâmetro da capsulorrexe, pelo mesmo cirurgião, no período de 1998 a 2002, com implante de lente intra-ocular hidrofílica expansível. O acompanhamento médio foi de 2,4 anos, variando de seis meses a quatro anos. RESULTADOS: O número total de opacificação de cápsula posterior foi de 54 casos. CONCLUSÃO: A incidência de opacificação de cápsula posterior encontrada no grupo foi de 4,6%.PURPOSE: To evaluate prospectively the results of expandable acrylic intraocular lenses in patients submitted to phacoemulsification as regard posterior capsule opacification. METHODS: The study group consisted of 830 patients, 1,200 eyes that underwent phacoemulsification from 1998 to 2002, by the same surgeon, using the same technique but with different diameters of capsulorrhexis, with expandable hydrophilic acrylic intraocular lens implantation. The mean follow-up was 2.4 years, ranging from 6 months to 4 years. RESULTS: The total number of posterior capsule opacification was 54 cases. CONCLUSIONS: The incidence of posterior capsule opacification was 4.6% in these patients.

  18. Single lens to lens duplication: The missing link

    OpenAIRE

    Bhatt, Rupal; Jethani, Jitendra; Saluja, Praveen; Bharti, Vinay

    2008-01-01

    Congenital anomalies of the lens include a wide range from lens coloboma to primary aphakia and doubling of lens. There have been few case reports of double lens; the etiology suggested is metaplastic changes in the surface ectoderm that leads to formation of two lens vesicles and hence resulting in double lens. We report a case with bilobed lens, which raises the possibility of explaining the etiology of double lens.

  19. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  20. Aberration design of zoom lens systems using thick lens modules.

    Science.gov (United States)

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  1. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  2. Visual outcome with the Oculentis Mplus intraocular lens

    OpenAIRE

    Si-Yuan Liu; Xu Yang

    2017-01-01

    AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL).METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOL)were as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At ...

  3. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  4. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  5. Opaque iris claw lens in a phakic eye to correct acquired diplopia

    NARCIS (Netherlands)

    Landesz, M; Worst, JGF; Rij, GV; Houtman, WA

    1997-01-01

    A 25-year-old man had diplopia caused by abducens nerve paresis on both sides after cranial injury. Because of the patient's reports of persistent diplopia after surgical correction, a specially manufactured, tinted iris claw lens was implanted in the left eye, with the crystalline lens in situ.

  6. The low-field permanent magnet electrostatic plasma lens

    International Nuclear Information System (INIS)

    Goncharov, A.; Gorshkov, V.; Maslov, V.; Zadorozhny, V.; Brown, I.

    2004-01-01

    We describe the status of ongoing research and development of the electrostatic plasma lens as used for the manipulation of high current broad beams of heavy ions of moderate energy. In some collaborative work at Lawrence Berkeley National Laboratory the lens was used to good effect for carrying out high dose ion implantation processing. In the process of this work a very narrow range of low magnetic field was found for which the ion-optical characteristics of the lens improved markedly. Subsequent theoretical analysis and computer modeling has led to an understanding of this phenomenon. These serendipitous results open up some attractive possibilities for the development of a new compact and low cost plasma lens based on permanent magnets rather than on current-driven field coils surrounding the lens volume. The development of this kind of lens, including both very low noise and minimal spherical aberration effects, may lead to a tool suitable for use in the injection beam lines of high current heavy ion linear accelerators. Here we briefly review the lens fundamentals, some characteristics of focusing heavy ion beams at low magnetic fields, and summarize recent theoretical and experimental developments, with emphasis on the relevance and suitability of the lens for accelerator injection application

  7. Necrotizing nocardial scleritis after combined penetrating keratoplasty and phacoemulsification with intraocular lens implantation: a case report and review of the literature Esclerite necrosante por Nocardia após ceratoplastia penetrante e facoemulsificação com implante de lente intra-ocular: caso clínico e revisão de literatura

    Directory of Open Access Journals (Sweden)

    Jerome Charles Ramos-Esteban

    2007-03-01

    Full Text Available We report the history and clinical presentation of an 88-year-old female with Fuchs dystrophy who developed an acute anterior necrotizing scleritis in her left eye 23 months after an uncomplicated combined penetrating keratoplasty and phacoemulsification with intraocular lens implantation which progressed to slceral perforation with uveal prolapses. The patient underwent a complete systemic work-up for both autoimmune and infectious causes of scleritis. Surgical specimens of the area of scleral perforation were sent for histology and microbiologic studies. Analysis of surgical specimens revealed the presence of culture-proven Nocardia asteroides as a causative agent for the patient's scleral perforation. Results of her systemic autoimmune work-up were not conclusive. Successful treatment with tectonic scleral reinforcement with donor corneal tissue and preserved pericardium, oral and topical trimethoprim-sulfamethoxazole and topical amikacin salvaged the globe and increased vision. The patient's final best-corrected visual acuity sixteen months after her last operation remains 20/70. Prompt surgical intervention with submission of appropriate specimens for pathological diagnosis and microbiology, along with consultation with rheumatologic and infectious disease specialists, are mandatory to minimize visual loss in cases of suspected infectious necrotizing scleritis.Relato de caso de esclerite necrosante aguda, evoluindo para perfuração escleral com prolapso uveal, 23 meses após procedimento de ceratoplastia penetrante e facoemulsificação com implante de lente intra-ocular no olho esquerdo sem intercorrências.A paciente foi submetida à avaliação completa auto-imune para esclerite. Biópsia da área de perfuração escleral foi encaminhada para avaliação patológica e microbiológica. Análise de material cirúrgico revelou presença de cultura proveniente de Nocardia asteroides como agente causal da perfuração escleral. Resultados de

  8. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Simon, V., E-mail: viosimon@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Radu, T.; Vulpoi, A. [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Rosca, C. [Optilens Clinic of Ophthalmology, 400604 Cluj-Napoca (Romania); Eniu, D. [Iuliu Haţieganu University of Medicine and Pharmacy, Department of Molecular Sciences, 400349 Cluj-Napoca (Romania)

    2015-01-15

    Highlights: • Changes on intraocular lens (IOL) surface after implantation. • Partial opacification of IOL central area. • Elemental composition on IOL surface prior to and after implantation. • First XPS depth profiling examination of the opacifying deposits. • Cell-mediated hydroxyapatite structuring. - Abstract: The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  9. Capsular 'pits' in the human lens.

    OpenAIRE

    Harris, M. L.; Brown, N. A.; Shun-Shin, G. A.; Smith, G. T.

    1992-01-01

    The lens capsule is an atypical basement membrane surrounding the lens epithelial cells and lens fibres which make up the remainder of the human lens. A seemingly unreported morphological change visible in the lens capsule with the biomicroscope is described.

  10. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  11. Surgical treatment of hereditary lens subluxations.

    Science.gov (United States)

    Ozdek, Sengul; Sari, Ayca; Bilgihan, Kamil; Akata, Fikret; Hasanreisoglu, Berati

    2002-01-01

    To evaluate the effectiveness and results of pars plana vitreolensectomy approach with transscleral fixation of intraocular lens in hereditary lens subluxations. Fifteen eyes of 9 consecutive patients with a mean age of 12.8+/-6.2 years (6-26 years) with hereditary lens subluxation were operated on and the results were evaluated in a prospective study. Surgery was considered if best spectacle corrected visual acuity (BSCVA) was less than 20/70. All eyes underwent a 2-port pars plana vitreolensectomy and transscleral fixation of an intraocular lens (IOL). The mean follow-up period was 12.6+/-7.5 months (6-22 months). There was no major intraoperative complication. Preoperatively, 8 eyes (53.3%) had a BSCVA of counting fingers (CF) and 7 eyes (46.6%) had a BSCVA of 20/200 to 20/70. Postoperatively, 14 eyes (93.3%) had a BSCVA of 20/50 or better. None of the patients had IOL decentration or intraocular pressure (IOP) increase during the follow-up period. There was a macular hole formation in 1 eye postoperatively. The early results of pars plana vitreolensectomy with IOL implantation using scleral fixation technique had shown that it not only promises a rapid visual rehabilitation but it is also a relatively safe method. More serious complications, however, may occur in the long term.

  12. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  13. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  14. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  15. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  18. The lens and cataracts.

    Science.gov (United States)

    Matthews, Andrew G

    2004-08-01

    It is conservatively estimated that some form of lens opacity is present in 5% to 7% of horses with otherwise clinically normal eyes.These opacities can range from small epicapsular remnants of the fetal vasculature to dense and extensive cataract. A cataract is defined technically as any opacity or alteration in the optical homogeneity of the lens involving one or more of the following: anterior epithelium, capsule, cortex, or nucleus. In the horse, cataracts rarely involve the entire lens structure (ie, complete cataracts) and are more usually localized to one anatomic landmark or sector of the lens. Complete cataracts are invariably associated with overt and significant visual disability. Focal or incomplete cataracts alone seldom cause any apparent visual dysfunction in affected horses,however.

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but ... require the same level of care or consideration as a standard contact lens because they can be ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... With Proper Contact Lens Care Apr 23, 2018 Solar Eclipse Inflicts Damage in the Shape of the ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... valid prescription that includes the brand name, lens measurements, and expiration date. Purchase the colored contact lenses ... with human-made versions. U.S. News Highlights the Value of Ophthalmologists APR 20, 2018 By Dan T. ...

  5. Vortex gas lens

    Science.gov (United States)

    Bogdanoff, David W.; Berschauer, Andrew; Parker, Timothy W.; Vickers, Jesse E.

    1989-01-01

    A vortex gas lens concept is presented. Such a lens has a potential power density capability of 10 to the 9th - 10 to the 10th w/sq cm. An experimental prototype was constructed, and the divergence half angle of the exiting beam was measured as a function of the lens operating parameters. Reasonably good agreement is found between the experimental results and theoretical calculations. The expanded beam was observed to be steady, and no strong, potentially beam-degrading jets were found to issue from the ends of the lens. Estimates of random beam deflection angles to be expected due to boundary layer noise are presented; these angles are very small.

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  11. Symmetric lens with extended depth of focus

    OpenAIRE

    Cho, Sung Nae

    2008-01-01

    The lens surface profile is derived based on the instantaneous focal length versus the lens radius data. The lens design based on instantaneous focal length versus the lens radius data has many useful applications in software assisted image focusing technology.

  12. Refractive Lens Exchange with Multifocal Intraocular Lens for Treatment of Chronic Intermittent Spasm of the Near Reflex

    Directory of Open Access Journals (Sweden)

    Guy Sallet

    2017-12-01

    Full Text Available We report the case of an emmetropic 32-year-old female with decreased uncorrected visual acuity and diplopia due to intermittent episodes of spasm of the near reflex. Neurologic, general, and ophthalmic examination could not find an organic cause. Attempts at spontaneous recovery, psychogenic therapy, and cycloplegic therapy were unsuccessful and the symptoms persisted for almost 5 years, leading to psychogenic distress. Final treatment with refractive lens exchange and implantation of a toric trifocal intraocular lens resolved the spasm of the near reflex, resulting in an uncorrected distance and near visual acuity of 20/20.

  13. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  14. Scleral suspension pars-plana lensectomy for ectopia lentis followed by suture fixation of intraocular lens

    Directory of Open Access Journals (Sweden)

    Mitra Sandip

    2001-01-01

    Full Text Available Purpose: To describe a simple technique of scleral suspension-pars plana lensectomy (SS-PPL in acquired and congenital ectopia lentis and scleral fixation of intraocular lens (IOL. Materials and Methods: Twenty eyes of 16 patients (12 unilateral and 4 bilateral cases of "essential familial lens subluxation" aged 10-40 years (mean 25 years underwent SS-PPL with implantation of scleral fixated IOL. Indications for surgery were best-corrected visual acuity <6/18, bisection of pupil by the lens, and lens-induced glaucoma. Prerequisites for SS-PPL were, visibility of part of the lens in the pupillary area and soft lens. Results: Postoperative visual acuity ranged from 6/6 - 6/36. Lens tilt in 3 cases(15% and small decentration in 2 cases(10% were seen; however these did not seriously compromise the visual result. Scant vitreous bleeding on the first postoperative day was seen in 3 cases (15%. Conclusion: The advantages of the scleral suspension of subluxated lens prior to lensectomy include stabilization; it allows proper viewing of the lens, avoids injury to the iris and cliary body during lensectomy and reduces the possibility of dislocation of the lens.

  15. A Tribute to Len Barton

    Science.gov (United States)

    Tomlinson, Sally

    2010-01-01

    This article constitutes a short personal tribute to Len Barton in honour of his work and our collegial relationship going back over 30 years. It covers how Len saw his intellectual project of providing critical sociological and political perspectives on special education, disability and inclusion, and his own radical political perspectives. Len's…

  16. Luneburg lens in silicon photonics.

    Science.gov (United States)

    Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf

    2011-03-14

    The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms.

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  18. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  19. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  20. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  2. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into ...

  4. Scleral fixation of a single-piece multifocal intraocular lens.

    Science.gov (United States)

    Can, Ertugrul; Basaran, M Resat; Gül, Adem

    2013-01-01

    We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectacle-corrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL.

  5. [To exercise caution in developing intraocular lens exchange].

    Science.gov (United States)

    Song, X D; Wang, X Z; Qian, J

    2018-05-11

    Nowadays cataract extraction combined intraocular lens (IOL) implantation has become the conventional treatment for cataract. Numbers of IOL exchange after cataract extraction combined IOL implantation have been increasing in recent years. As a non-routine surgery, IOL exchange is normally combined with other surgeries and accompanied by some complications to various extents. Is IOL exchange necessary for all abnomal IOLs? Can IOL exchange be avoided? How to avoid IOL exchange? The purpose of this article is to stress the importance of indication of IOL exchange and how to avoid IOL exchange. (Chin J Ophthalmol, 2018, 54: 324-327) .

  6. Evaluation of Artisan aphakic intraocular lens in cases of pediatric aphakia with insufficient capsular support.

    Science.gov (United States)

    Gawdat, Ghada I; Taher, Sameh G; Salama, Marwa M; Ali, Adel A

    2015-06-01

    To evaluate the visual outcomes and complications after Artisan iris-claw lens implantation in aphakic children with insufficient capsular support. In this prospective, interventional noncontrolled study, aphakic eyes of consecutive patients >2 years of age with insufficient capsular support who underwent Artisan intraocular lens (IOL) implantation between June 2011 and December 2012 were followed for 1 year. Patients with anterior chamber depth IOL were included, 18 eyes with subluxated lens and 7 following trauma. The mean preoperative logMAR best-corrected visual acuity for traumatic aphakic patients was 0.95 ± 0.36; for patients with subluxation, 0.7 ± 0.26. Values improved at 1 year to 0.38 ± 0.15 (P IOL implantation for pediatric aphakia achieved a good visual outcome. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  7. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  8. Intraocular lens subluxation in a patient with facial atopic dermatitis.

    Science.gov (United States)

    Yamazaki, S; Nakamura, K; Kurosaka, D

    2001-02-01

    A 66-year-old Japanese man presented with subluxation of a posterior chamber intraocular lens (IOL) caused by a rupture of part of Zinn's zonule but no retinal break 2 years after phacoemulsification with IOL implantation. He had a history of atopic dermatitis since infancy. This case presents a rare ocular complication of scratching and rubbing the face and eyelids because of itching related to atopic dermatitis.

  9. Comparação entre os resultados pós-operatórios de pacientes submetidos ao procedimento tríplice e transplante de córnea combinado a fixação secundária de lente intra-ocular Comparison between the postoperative results of triple procedure and combined penetrating keratoplasty/ transsclerally sutured posterior chamber lens implantation

    Directory of Open Access Journals (Sweden)

    Daniela Maggioni Pereira Leão

    2006-08-01

    Full Text Available OBJETIVO: Comparar os resultados pós-operatórios de 2 grupos de pacientes submetidos a transplante de córnea com técnicas e tempo cirúrgico diferentes, em relação à abordagem do cristalino e/ou lente intra-ocular. MÉTODOS: Neste estudo retrospectivo foram analisados 37 olhos de pacientes divididos em 2 grupos: extração de catarata, implante de lentes intra-oculares (LIO e transplante de córnea no mesmo tempo cirúrgico - grupo 1 (G1 e extração de catarata sem implante de lentes intra-oculares no primeiro tempo cirúrgico e fixação secundária de lentes intra-oculares associada a transplante de córnea no segundo tempo cirúrgico - grupo 2 (G2. As variáveis estudadas foram: acuidade visual, pressão intra-ocular (PIO, astigmatismo refracional, astigmatismo ceratométrico e complicações pós-operatórias. RESULTADOS: Foi observado melhora da acuidade visual nos 2 grupos (G1 pPURPOSE: To compare the outcomes of two surgical techniques of penetrating keratoplasty with different surgical time, regarding the crystalline and the intraocular lens. METHODS: This retrospective study included 37 patients' eyes divided into 2 groups: extracapsular cataract extraction, posterior chamber intraocular lens implantation and penetrating keratoplasty (Group 1, G1 and transscleral fixation of posterior chamber lens and penetrating keratoplasty (Group 2, G2. The following parameters were recorded: visual acuity, intraocular pressure, refractive astigmatism, complication and keratometric astigmatism. RESULTS: Visual acuity improved in the two groups (G1 p<0.001 and G2 p=0.008. In G2 a significant change for the worse of intraocular pressure outcome was observed when compared with the other group (p=0.014. Regarding refractive and keratometric astigmatism no significant differences between the groups were found. The follow-up was 11 months. CONCLUSION: The most important negative prognostic factor affecting visual acuity was the postkeratoplasty

  10. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  11. Pigment dispersion and Artisan phakic intraocular lenses: crystalline lens rise as a safety criterion.

    Science.gov (United States)

    Baïkoff, Georges; Bourgeon, Grégoire; Jodai, Horacio Jitsuo; Fontaine, Aline; Lellis, Fernando Viera; Trinquet, Laure

    2005-04-01

    To validate the theory that crystalline lens rise can be used as a safety criterion to prevent pigment dispersion in eyes with an Artisan phakic intraocular lens (IOL) (Ophtec BV). Monticelli Clinic, Marseilles, France. A comparative analysis of crystalline lens rise in 9 eyes with pigment dispersion and 78 eyes without dispersion was performed. All eyes had previous implantation of an Artisan IOL. Anterior segment imaging was done using an anterior chamber optical coherence tomography (AC OCT) prototype. Crystalline lens rise was defined by the distance between the anterior pole of the crystalline lens and the horizontal plane joining the opposite iridocorneal recesses. The study confirmed that crystalline lens rise can be considered a safety criterion for implantation of Artisan-type phakic IOLs. The higher the crystalline lens rise, the greater the risk for developing pigment dispersion in the area of the pupil. This complication occurred more frequently in hyperopic eyes than in myopic eyes. Results indicate there is little or no risk for pigment dispersion if the rise is less than 600 microm; 67% of eyes with a rise of 600 microm or more developed pupillary pigment dispersion. In some cases in which the IOL was loosely fixated, there was no traction on the iris root and dispersion was prevented or delayed. Crystalline lens rise should be considered a new safety criterion for Artisan phakic IOL implantation and should also be applied to other types of phakic IOLs. The distance remaining between the crystalline lens rise and a 600 microm theoretical safety level allows one to calculate how long the IOL can safely remain in the eye.

  12. Clinical observation of four-fixable intraocular lens suspensory

    Directory of Open Access Journals (Sweden)

    Yu-Ming Teng

    2015-06-01

    Full Text Available AIM: To discuss the four-fixable intraocular lens(IOLsuspensory in the absence of capsular intraocular lens implantation, suspensory ligament rupture caused by congenital dislocation of the lens, traumatic cataract and posterior capsular rupture without capsular support, which need to line hanging IOL for intraoperative clinical observation.METHODS: The 31 cases(32 eyeswho were accepted the four-fixable IOL suspensory from May 2012 to May 2014 in our hospital were retrospectively analyzed. The postoperative visual acuity, corneal astigmatism, intraoperative and postoperative complications were comprehensively analyzed.RESULTS: Patients were followed up 6mo~1a, corrected visual acuity >0.5(12 eyes, 38%, 0.1~0.5(18 eyes, 56%, and CONCLUSION: It is designed to support non-capsular IOL implantation and design, and the concept of changing the past presence of suspended dislocated IOL implantation surgery, positional deviation and, sutures and other complications split the incidence is greatly reduced. It is consistent with the physiological characteristics of the human eye, and it is the IOL surgical sling best stability, intraoperative and postoperative complications, the best visual acuity and corneal astigmatism minimal surgical approachat least, and the four-point suspension suture fixation of IOL is designed to obtain a practical transformation of Chinese patent.

  13. Small-Gauge Pars Plana Vitrectomy for the Management of Symptomatic Posterior Vitreous Detachment after Phacoemulsification and Multifocal Intraocular Lens Implantation: A Pilot Study from the Pan-American Collaborative Retina Study Group

    Science.gov (United States)

    Navarro, Rodrigo M.; Machado, Leonardo M.; Maia, Ossires; Wu, Lihteh; Farah, Michel E.; Magalhaes, Octaviano; Arevalo, J. Fernando; Maia, Mauricio

    2015-01-01

    Purpose. To determine the efficacy of 23-gauge pars plana vitrectomy (PPV) for symptomatic posterior vitreous detachment (PVD) on visual acuity (VA) and quality after multifocal intraocular lenses (IOLs). Methods. In this prospective case series, patients who developed symptomatic PVD and were not satisfied with visual quality due to floaters and halos after multifocal IOL implantation underwent PPV. Examinations included LogMAR uncorrected visual acuity (UCVA), intraocular pressure, biomicroscopy, and indirect ophthalmoscopy at baseline and 1, 7, 30, and 180 days postoperatively. Ultrasonography and aberrometry were performed. The Visual Functioning Questionnaire 25 (VFQ-25) was administered preoperatively and at 30 days postoperatively. Both the postoperative UCVA and questionnaire results were compared to preoperative findings using the Wilcoxon test. Results. Sixteen eyes of 8 patients were included. VA significantly improved from 0.17 to 0.09 postoperatively (P = 0.017). All patients reported improvement of halos, glare, and floaters. VFQ-25 scores significantly improved in general vision (P = 0.023), near activities (P = 0.043), distance activities (P = 0.041), mental health (P = 0.011), role difficulties (P = 0.042), and driving (P = 0.016). Conclusion. PPV may increase UCVA and quality of vision in patients with bilateral multifocal IOLs and symptomatic PVD. Larger studies are advised. PMID:26504590

  14. A Correlation of Thin Lens Approximation to Thick Lens Design by Using Coddington Factors in Lens Design and Manufacturing

    OpenAIRE

    FARSAKOĞLU, Ö. Faruk

    2014-01-01

    The effect of Coddington factors on aberration functions has been analysed using thin lens approximation. Minimizing spherical aberrations of singlet lenses using Coddington factors in lens design depending on lens manufacturing is discussed. Notation of lens test plate pairs used in lens manufacturing is also presented in terms of Coddington shape factors.

  15. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    Science.gov (United States)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... have given blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough sight to read again after getting stem cell implants in their damaged eyes. ... EyeSmart Resources for Professionals Link your website to EyeSmart Embed ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... enough sight to read again after getting stem cell implants in their damaged eyes. Ocular Melanoma Cases Getting Nationwide Attention MAY 03, ... re edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. U.S. News Highlights ...

  18. Characteristics of the thick, compound refractive lens

    International Nuclear Information System (INIS)

    Pantell, Richard H.; Feinstein, Joseph; Beguiristain, H. Raul; Piestrup, Melvin A.; Gary, Charles K.; Cremer, Jay T.

    2003-01-01

    A compound refractive lens (CRL), consisting of a series of N closely spaced lens elements each of which contributes a small fraction of the total focusing, can be used to focus x rays or neutrons. The thickness of a CRL can be comparable to its focal length, whereupon a thick-lens analysis must be performed. In contrast with the conventional optical lens, where the ray inside the lens follows a straight line, the ray inside the CRL is continually changing direction because of the multiple refracting surfaces. Thus the matrix representation for the thick CRL is quite different from that for the thick optical lens. Principal planes can be defined such that the thick-lens matrix can be converted to that of a thin lens. For a thick lens the focal length is greater than for a thin lens with the same lens curvature, but this lengthening effect is less for the CRL than for the conventional optical lens

  19. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

  20. Subluxation of the crystalline lens: a no-ring approach.

    Science.gov (United States)

    Rodrigues, Antonio Carlos L; Trivedi, Rupal H; Wilson, M Edward

    2012-01-01

    To report the surgical technique and outcomes of a no-ring approach to posterior chamber intraocular lens (IOL) implantation in children and young adults with subluxation of the crystalline lens. A three-piece 5.5-mm hydrophobic acrylic IOL was implanted in which the optic and one haptic were inside the capsular bag and the other haptic was in the ciliary sulcus. The implantations were done in 13 eyes of 10 patients with lens subluxation. One haptic was fixated in the ciliary sulcus by passing it through an operculum-shaped opening in the capsular bag edge, made between 2 and 3 clock hours, clockwise from the middle point of the subluxated area. The mean age of the 10 patients was 12.61 ± 8.04 years and the mean follow-up was 21.38 ± 11.29 months. The mean preoperative and postoperative best-corrected visual acuity (BCVA) was 1.15 ± 0.58 and 0.37 ± 0.17 logarithm of the minimum angle of resolution, respectively, in 11 measured eyes. The postoperative BCVA was 20/40 or better in 4 eyes (36.36%), between 20/40 and 20/60 in 6 eyes (54.54%), and between 20/80 and 20/100 in 1 eye (9.09%). The BCVA improved in all eyes. Postoperative IOL decentration between 1.0 and 1.5 mm occurred in 3 of 13 eyes (23.08%). The results indicate that the no-ring technique allows centration of an IOL implanted into a subluxated capsular bag without using capsule tension rings. Copyright 2012, SLACK Incorporated.

  1. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  2. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  3. Wedged multilayer Laue lens

    International Nuclear Information System (INIS)

    Conley, Ray; Liu Chian; Qian Jun; Kewish, Cameron M.; Macrander, Albert T.; Yan Hanfei; Maser, Joerg; Kang, Hyon Chol; Stephenson, G. Brian

    2008-01-01

    A multilayer Laue lens (MLL) is an x-ray focusing optic fabricated from a multilayer structure consisting of thousands of layers of two different materials produced by thin-film deposition. The sequence of layer thicknesses is controlled to satisfy the Fresnel zone plate law and the multilayer is sectioned to form the optic. An improved MLL geometry can be created by growing each layer with an in-plane thickness gradient to form a wedge, so that every interface makes the correct angle with the incident beam for symmetric Bragg diffraction. The ultimate hard x-ray focusing performance of a wedged MLL has been predicted to be significantly better than that of a nonwedged MLL, giving subnanometer resolution with high efficiency. Here, we describe a method to deposit the multilayer structure needed for an ideal wedged MLL and report our initial deposition results to produce these structures

  4. Intraocular camera for retinal prostheses: Refractive and diffractive lens systems

    Science.gov (United States)

    Hauer, Michelle Christine

    The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.

  5. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  6. Refractive outcomes after multifocal intraocular lens exchange.

    Science.gov (United States)

    Kim, Eric J; Sajjad, Ahmar; Montes de Oca, Ildamaris; Koch, Douglas D; Wang, Li; Weikert, Mitchell P; Al-Mohtaseb, Zaina N

    2017-06-01

    To evaluate the refractive outcomes after multifocal intraocular lens (IOL) exchange. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. Patients had multifocal IOL explantation followed by IOL implantation. Outcome measures included type of IOL, surgical indication, corrected distance visual acuity (CDVA), and refractive prediction error. The study comprised 29 patients (35 eyes). The types of IOLs implanted after multifocal IOL explantation included in-the-bag IOLs (74%), iris-sutured IOLs (6%), sulcus-fixated IOLs with optic capture (9%), sulcus-fixated IOLs without optic capture (9%), and anterior chamber IOLs (3%). The surgical indication for exchange included blurred vision (60%), photic phenomena (57%), photophobia (9%), loss of contrast sensitivity (3%), and multiple complaints (29%). The CDVA was 20/40 or better in 94% of eyes before the exchange and 100% of eyes after the exchange (P = .12). The mean refractive prediction error significantly decreased from 0.22 ± 0.81 diopter (D) before the exchange to -0.09 ± 0.53 D after the exchange (P exchange to 0.23 D after the exchange (P exchange can be performed safely with good visual outcomes using different types of IOLs. A lower refractive prediction error and a higher likelihood of 20/40 or better vision can be achieved with the implantation of the second IOL compared with the original multifocal IOL, regardless of the final IOL position. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p rate, self grading was relatively high. Therefore, these results indicate the need for patient education and encouragement of better lens wearing habits and all of the lens maintenance steps at each patient visit.

  8. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  9. 21 CFR 886.1375 - Bagolini lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bagolini lens. 886.1375 Section 886.1375 Food and... OPHTHALMIC DEVICES Diagnostic Devices § 886.1375 Bagolini lens. (a) Identification. A Bagolini lens is a device that consists of a plane lens containing almost imperceptible striations that do not obscure...

  10. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  11. Immunohistochemical studies of lens crystallins in the dysgenetic lens (dyl) mutant mice

    NARCIS (Netherlands)

    Brahma, S.K.; Sanyal, S.

    1984-01-01

    The lens in the dyl mutant mice shows a persistent lens-ectodermal connection as well as degeneration and extrusion of lens materials after the initial differentiation of the fibres. Immunohistochemical investigation of the ontogeny of the lens crystallins in this developing mutant lens has been

  12. Contact Lens Visual Rehabilitation in Keratoconus and Corneal Keratoplasty

    Directory of Open Access Journals (Sweden)

    Yelda Ozkurt

    2012-01-01

    Full Text Available Keratoconus is the most common corneal distrophy. It’s a noninflammatory progressive thinning process that leads to conical ectasia of the cornea, causing high myopia and astigmatism. Many treatment choices include spectacle correction and contact lens wear, collagen cross linking, intracorneal ring segments implantation and finally keratoplasty. Contact lenses are commonly used to reduce astigmatism and increase vision. There are various types of lenses are available. We reviewed soft contact lenses, rigid gas permeable contact lenses, piggyback contact lenses, hybrid contact lenses and scleral-semiscleral contact lenses in keratoconus management. The surgical option is keratoplasty, but even after sutur removal, high astigmatism may stil exists. Therefore, contact lens is an adequate treatment option to correct astigmatism after keratoplasty.

  13. Analysis of causes of intraocular lens explantations in the material of Department of Ophthalmology, Medical University of Lodz.

    Science.gov (United States)

    Wilczyński, Michał; Wilczyńska, Olena; Omulecki, Wojciech

    2009-01-01

    Implantation of intraocular lenses (IOLS) has become a standard practice in cataract surgery, however, similar to any other type of surgery, using IOLs is not complication-free and sometimes explantation of intraocular lenses may be necessary. This study was to gather data and analyze causes of intraocular lens explantations, performed in the Department of Ophthalmology, Medical University of Łódź. The data were gathered from medical documentation of all patients who underwent intraocular lens removal from January 2003 to July 2006. The examined group consisted of 16 patients (16 eyes): 9 women (fraction 0.56), and 7 men (fraction 0.44), at the age from 21 to 82 years (mean age 62.4 years, SD +/- 15.5). In all patients IOL explantation was performed under local, peribulbar anaesthesia. Two groups of patients were distinguished: patients who had an anterior chamber lens explanted (3 patients, fraction 0.19) and patients who underwent posterior chamber lens explantation (13 patients, fraction 0.81). Causes of AC IOL explantations were: vaulting of the IOL (1 eye, fraction 0.06), luxation of the IOL to the vitreous cavity (1 eye, fraction 0.06), and painful eyeball after anterior chamber lens implantation (1 eye, fraction 0.06). Causes of PC IOL explantations were: subluxation of the IOL (6 eyes, fraction 0.38), luxation of the lens to the vitreous cavity (3 eyes, fraction 0.19), luxation of the lens to the anterior chamber (1 eye, fraction 0.06), endophthalmitis (2 eyes, fraction 0.13) and incorrect lens power (1 eye, fraction 0.06). In the majority of eyes (n = 13, fraction 0.81) the removed implant was replaced by another intraocular lens, but 3 eyes (fraction 0.19) were left aphakic. We did not observe serious intra- or early postoperative complications which might influence the final result of the operation.

  14. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  15. Crystalline lens and refractive development.

    Science.gov (United States)

    Iribarren, Rafael

    2015-07-01

    Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Single lens laser beam shaper

    Science.gov (United States)

    Liu, Chuyu [Newport News, VA; Zhang, Shukui [Yorktown, VA

    2011-10-04

    A single lens bullet-shaped laser beam shaper capable of redistributing an arbitrary beam profile into any desired output profile comprising a unitary lens comprising: a convex front input surface defining a focal point and a flat output portion at the focal point; and b) a cylindrical core portion having a flat input surface coincident with the flat output portion of the first input portion at the focal point and a convex rear output surface remote from the convex front input surface.

  17. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  18. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  19. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  20. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  1. Sectioning a luxated intraocular lens inside the vitreous cavity.

    Science.gov (United States)

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  3. Comparison of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients

    Directory of Open Access Journals (Sweden)

    Zhan-Jiang Liu

    2016-01-01

    Full Text Available AIM:To investigate the effects of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients. METHODS:Seventy-seven patients(128 eyeswere treated by phacoemulsification combined with intraocular lens implantation from January 2014 to March 2015 in our hospital. Thirty-nine patients(65 eyeswere treated with Bigbag intraocular lens, 38 cases(63 eyeswere treated with Rayner620H. The best corrected visual acuity(BCVAdistribution, the actual refractive value, the difference between predictive refractive value and actual refractive value and complications were measured and recorded in the two groups at 1mo after surgeries. RESULTS:The difference between the two groups on BCVA are statistically significant(PWilcoxon rank sum test. The differences between predictive refractive value and actual refractive value of the two groups were statistically significant(PPCONCLUSION:The effect of Bigbag intraocular lens for patients with phacoemulsification and intraocular lens implantation is good, and it can reduce the risk of complications.

  4. [Clinical applications of ultrasound biomicroscopy in diagnosis and treatment of lens subluxation].

    Science.gov (United States)

    Liu, Yi-Zhi; Liu, Yu-Hua; Wu, Ming-Xing; Luo, Li-Xia; Zhang, Xin-Yu; Cai, Xiao-Yu; Chen, Xiu-Qi

    2004-03-01

    To evaluate the clinical value in diagnosis and treatment of lens subluxation using ultrasound biomicroscopy (UBM). This study comprised 29 patients (32 eyes) that had cataract with subluxated lenses due to different causes admitted into our hospital between November 2000 and January 2002. All eyes received UBM examination preoperatively and postoperatively. Capsular tension ring (CTR) implantations were performed using different technique according to UBM examination. Then all patients received phacoemulsification and intraocular lens (IOL) implantation. The location of IOL and CTR and complications were evaluated postoperatively. Different kinds of subluxated lens shown different manifestations in UBM. The degree of zonular defect can be evaluated with UBM preoperatively. With UBM examination preoperatively, extent of lens subluxation less than 1/2 quadrant in 19 eyes while more than 1/2 quadrant in other 13 eyes were observed. Postoperative UBM examination in this series shown that CTRs were holding in place except one attached to the iris root. IOLs in 29 eyes were in proper position while IOLs in 3 patients were slightly tilted. The degree and extent of lens subluxation can be evaluated using UBM examinations preoperatively, which is necessary in the selection of surgical protocol. With postoperative UBM examinations, a precise observation on the actual location of CTR and IOL can be achieved to produce an objective evaluation of the surgical outcomes.

  5. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  6. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  7. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  8. Lens system for SIMS analysis

    International Nuclear Information System (INIS)

    Martinez, G.; Sancho, M.; Garcia-Galan, J.C.

    1987-01-01

    A powerful version of the charge-density method is applied to the study of a combined objective and emission lens, suitable for highly localized analysis of a flat sample surface. This lens can extract secondary ions of equal or opposite polarity to that of the primary particles. A computer simulation of the ion trajectories for both modes is made. The behaviour for different values of the geometric parameters and polarizations is analyzed and useful data for design such as primary beam demagnification and secondary image position are given. (author) 4 refs

  9. Visual outcome with the Oculentis Mplus intraocular lens

    Directory of Open Access Journals (Sweden)

    Si-Yuan Liu

    2017-11-01

    Full Text Available AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL.METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOLwere as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At 3mo after surgery, distance visual acuity of test group with Oculentis Mplus IOL were 0.10±0.03,the difference with control group was not significant(t=1.74, P>0.05. Eyes in test group had an uncorrected near acuity 0.11±0.04, the difference with control group was significant(t=15.53, PCONCLUSION: The implantation of Oculentis Mplus IOL not only has a good distance uncorrected visual acuity, but also with better near visual acuity. The surgery is safe, reliable and no special complication induced.

  10. Stretchable Binary Fresnel Lens for Focus Tuning

    NARCIS (Netherlands)

    Li, X.; Wei, L.; Poelma, R.H.; Vollebregt, S.; Wei, J.; Urbach, Paul; Sarro, P.M.; Zhang, G.Q.

    2016-01-01

    This paper presents a tuneable binary amplitude Fresnel lens produced by wafer-level microfabrication. The Fresnel lens is fabricated by encapsulating lithographically defined vertically aligned carbon nanotube (CNT) bundles inside a polydimethyl-siloxane (PDMS) layer. The composite lens material

  11. 21 CFR 886.1400 - Maddox lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maddox lens. 886.1400 Section 886.1400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1400 Maddox lens. (a) Identification. A Maddox lens is a device...

  12. Crystalline lens power and refractive error.

    Science.gov (United States)

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P lens opacity grade (β = -0.42; P lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  13. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  14. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  15. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  16. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  17. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  18. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  19. Plasma Lens for Muon and Neutrino Beams

    Science.gov (United States)

    Kahn, Stephen; Korenev, Sergey; Bishai, Mary; Diwan, Milind; Gallardo, Juan; Hershcovitch, Ady; Johnson, Brant

    2008-04-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-current lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. A plasma lens has additional advantage: larger axial current than horns, minimal neutrino contamination during antineutrino running, and negligible pion absorption or scattering. Results from particle simulations using a plasma lens will be presented.

  20. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  1. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2009-03-01

    Full Text Available Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients or Marfan syndrome-associated ectopia lentis (nine patients with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS from grade 1 (lens on the whole pupillary area up to grade 4 (lens absent from the pupillary area. Thirty eyes underwent cataract extraction (“dry” aspiration with endocapsular ring and in-the-bag intraocular lens (IOL implantation. Twenty-one eyes underwent cataract extraction (“dry” aspiration with scleral fixation of the IOL. The predictive value of the LSGS was assessed by analyzing the post-operative outcomes, including visual acuity (VA, endothelial cell loss, and complications for each grade on the grading system. Rresults: Patients were classified into grade 1 (19.6%, grade 2 (51% and grade 3 (29.4%. Post-operative VA was lower for eyes with larger degrees of subluxation. The higher the subluxation grade, the higher the endothelial cell loss, as well as, the frequency of vitreous loss and surgical time. Higher subluxation grades prevented optimal surgical outcomes with endocapsular ring and in-the-bag IOL implantation. Cconclusions: The LSGS provides an estimate of the surgical success of ectopia lentis. Adequate standardization of lens subluxation is crucial for understanding studies dealing with the surgical correction of this disorder.

  2. Sensitivity of the corneal-plane refractive compensation to change in power and axial position of an intraocular lens

    Directory of Open Access Journals (Sweden)

    W. F. Harris

    2009-12-01

    Full Text Available If an intraocular lens is displaced or if its power is changed what are the consequences for the refractive compensation of the eye?  Gaussian optics is used to obtain explicit formulae for the sensitivityof the corneal-plane refractive compensation (also called the refraction, refractive state, etc to change in power and axial displacement of a thin intraocular lens implanted in a simple eye.  In particular, for a pseudophakic Gullstrand simplified eye with intraocular lens placed 5 mm behind the cornea the sensitivity to errors in the power of the intraocular lens is about  71 . 0 − 71 for an intraocular lens of power   for an intraocular lens of power 20 D, that is, the refractive compensation decreases by about 0.71 dioptres per dioptre increase in the power of the intraocular lens.  More generally the sensitivity is approximately  ( m   0037 . 0 63 . 0 F − − 0.63 ( 003 . 0 63 . 0 − − (0.0037mF where FI is the power of the intraocular lens.  Also for Gullstrand’s simplified eye the sensitivity of refractive compensation to axial displacement of the intraocular lens is approximately linear in FI about  (64D FI, in fact.  That is, for each dioptre of the power of the intraocular lens the refractive compensation increases by about 0.064 dioptres per millimetre of axial displacement towards the retina. 

  3. Follow up of intraocular lens subluxation with a combined topographer/aberrometer

    OpenAIRE

    Georgios A. Kontadakis; George D. Kymionis; Vardhaman P. Kankariya; Ioannis G. Pallikaris

    2012-01-01

    Purpose: To report a 36-year-old patient with intraocular lens (IOL) subluxation that was followed for IOL stability with evaluation of images captured with the iTrace combined aberrometer/topographer. Methods: The patient had undergone phacoemulsification with IOL implantation for congenital cataract 15 years before. He presented with bilateral IOL subluxation, more severe in his right eye. Right eye was operated for IOL exchange and left eye was followed with the iTrace images. The image...

  4. Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model insertion in the immediate postoperative period

    Directory of Open Access Journals (Sweden)

    Ganesh S

    2016-01-01

    Full Text Available Sri Ganesh, Sheetal BrarDepartment of Phaco and Refractive Surgeries, Nethradhama Superspeciality Eye Hospital, Bangalore, IndiaPurpose: To compare the effect of two ocular viscosurgical devices (OVDs on intraocular pressure (IOP and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model implantation.Methods: A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC in one eye and 1% hyaluronic acid in fellow eye. Time taken for complete removal of OVD and total surgical time were recorded. At the end of surgery, IOP was adjusted between 15 and 20 mmHg in both the eyes.Results: Mean time for complete OVD evacuation and total surgical time were significantly higher in the HPMC group (P=0.00. Four eyes in the HPMC group had IOP spike, requiring treatment. IOP values with noncontact tonometry at 1, 2, 4, 24, and 48 hours were not statistically significant (P>0.05 for both the groups.Conclusion: The study concluded that 1% hyaluronic acid significantly reduces total surgical time, and incidence of acute spikes may be lower compared to 2% HPMC when used for implantable collamer lens (V4c model.Keywords: OVD, hyaluronic acid, ICL, V4c, IOP spikes

  5. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  6. Lens Coupled Quantum Cascade Laser

    Science.gov (United States)

    Hu, Qing (Inventor); Lee, Alan Wei Min (Inventor)

    2013-01-01

    Terahertz quantum cascade (QC) devices are disclosed that can operate, e.g., in a range of about 1 THz to about 10 THz. In some embodiments, QC lasers are disclosed in which an optical element (e.g., a lens) is coupled to an output facet of the laser's active region to enhance coupling of the lasing radiation from the active region to an external environment. In other embodiments, terahertz amplifier and tunable terahertz QC lasers are disclosed.

  7. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  8. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  9. Glycation precedes lens crystallin aggregation

    International Nuclear Information System (INIS)

    Swamy, M.S.; Perry, R.E.; Abraham, E.C.

    1987-01-01

    Non-enzymatic glycosylation (glycation) seems to have the potential to alter the structure of crystallins and make them susceptible to thiol oxidation leading to disulfide-linked high molecular weight (HMW) aggregate formation. They used streptozotocin diabetic rats during precataract and cataract stages and long-term cell-free glycation of bovine lens crystallins to study the relationship between glycation and lens crystallin aggregation. HMW aggregates and other protein components of the water-soluble (WS) and urea-soluble (US) fractions were separated by molecular sieve high performance liquid chromatography. Glycation was estimated by both [ 3 H]NaBH 4 reduction and phenylboronate agarose affinity chromatography. Levels of total glycated protein (GP) in the US fractions were about 2-fold higher than in the WS fractions and there was a linear increase in GP in both WS and US fractions. This increase was parallelled by a corresponding increase in HMW aggregates. Total GP extracted by the affinity method from the US fraction showed a predominance of HMW aggregates and vice versa. Cell-free glycation studies with bovine crystallins confirmed the results of the animals studies. Increasing glycation caused a corresponding increase in protein insolubilization and the insoluble fraction thus formed also contained more glycated protein. It appears that lens protein glycation, HMW aggregate formation, and protein insolubilization are interrelated

  10. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  11. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  12. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Bruna Vieira Ventura

    Full Text Available ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  13. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  14. DISSECTING THE GRAVITATIONAL LENS B1608+656. I. LENS POTENTIAL RECONSTRUCTION

    NARCIS (Netherlands)

    Suyu, S. H.; Marshall, P. J.; Blandford, R. D.; Fassnacht, C. D.; Koopmans, L. V. E.; McKean, J. P.; Treu, T.

    2009-01-01

    Strong gravitational lensing is a powerful technique for probing galaxy mass distributions and for measuring cosmological parameters. Lens systems with extended source-intensity distributions are particularly useful for this purpose since they provide additional constraints on the lens potential (

  15. Role of Aquaporin 0 in lens biomechanics

    International Nuclear Information System (INIS)

    Sindhu Kumari, S.; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G.; Menon, Anil G.; Mathias, Richard T.; Varadaraj, Kulandaiappan

    2015-01-01

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5 −/− ), AQP0 KO (heterozygous KO: AQP0 +/− ; homozygous KO: AQP0 −/− ; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0 +/− lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to

  16. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  17. Freeform lens design for LED collimating illumination.

    Science.gov (United States)

    Chen, Jin-Jia; Wang, Te-Yuan; Huang, Kuang-Lung; Liu, Te-Shu; Tsai, Ming-Da; Lin, Chin-Tang

    2012-05-07

    We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performance of the lens, a prototype of the collimator lens is also made, and an optical efficiency of 90.3% with a beam angle of 4.75 deg is measured.

  18. Changes in lens stiffness due to capsular opacification in accommodative lens refilling

    NARCIS (Netherlands)

    Nibourg, Lisanne M.; Sharma, Prashant K.; van Kooten, Theo G.; Koopmans, Steven A.

    Accommodation may be restored to presbyopic lenses by refilling the lens capsular bag with a soft polymer. After this accommodative lens refilling prevention of capsular opacification is a requirement, since capsular opacification leads to a decreased clarity of the refilled lens. It has been

  19. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  20. Bilateral intraocular lens subluxation secondary to haptic angulation.

    Science.gov (United States)

    Moreno-Montañés, Javier; Fernández-Hortelano, Ana; Caire, Josemaría

    2008-04-01

    An 82-year-old man had uneventful phacoemulsification with bilateral implantation of a hydrophilic acrylic, single-piece intraocular lens (IOL) (ACR6D SE, Laboratoires Cornéal). Five years later, simultaneous and bilateral IOL subluxations occurred. In both eyes, the subluxation was situated on the side of one haptic that had moved forward (temporal area in the right eye and superior area in the left eye). In the right eye, the haptic-capsular bag was entrapped by the pupil and produced endothelial damage. A transscleral suture was placed over and under the subluxated haptic through the anterior and posterior capsules to capture the haptic. The haptic was then sutured to the sclera. No postoperative complications developed. We hypothesize that 10-degree angulated and broad haptic junctions can lead to zonular damage and IOL subluxation.

  1. The efficiency of aspheric intraocular lens according to biometric measurements.

    Science.gov (United States)

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  2. Lens design and local minima

    International Nuclear Information System (INIS)

    Brixner, B.

    1981-01-01

    The widespread belief that local minima exist in the least squares lens-design error function is not confirmed by the Los Alamos Scientific Laboratory (LASL) optimization program. LASL finds the optimum-mimimum region, which is characterized by small parameter gradients of similar size, small performance improvement per iteration, and many designs that give similar performance. Local minima and unique prescriptions have not been found in many-parameter problems. The reason for these absences is that image errors caused by a change in one parameter can be compensated by changes in the remaining parameters. False local minima have been found, and four cases are discussed

  3. Toric Intraocular Lens Outcomes in Patients With Glaucoma.

    Science.gov (United States)

    Brown, Reay H; Zhong, Le; Bozeman, Caroline W; Lynch, Mary G

    2015-06-01

    To report the outcomes of toric intraocular lens implantation in patients with glaucoma and corneal astigmatism. One hundred twenty-six eyes of 87 patients with glaucoma and corneal astigmatism that underwent cataract surgery with an AcrySof toric intraocular lens (Alcon Laboratories, Inc., Fort Worth, TX) implant were selected for this single-center, retrospective case series. Corrected distance visual acuity, intraocular pressure, and refractive astigmatism were measured in each eye preoperatively and postoperatively. Uncorrected distance visual acuity and toric alignment were measured postoperatively. The uncorrected distance visual acuity was 0.04 ± 0.08 logMAR (20/22 Snellen) for all eyes. Ninety-eight percent of all eyes achieved an uncorrected distance visual acuity of 20/40 or better, with 76% achieving 20/25 or better and 47% achieving 20/20. The corrected distance visual acuity for all eyes was 0.01 ± 0.03 logMAR (20/20.5 Snellen) postoperatively. The refractive cylinder improved from 1.47 ± 1.10 diopters preoperatively to 0.31 ± 0.37 diopters postoperatively. The residual refractive cylinder was 1.00 diopter or less in 97% of eyes, 0.75 diopters or less in 90% of eyes, and 0.50 diopters or less in 83% of eyes. Mean misalignment was 4.4° ± 5.1°. Intraocular pressure decreased by a mean of 2.3 ± 3.3 mm Hg following the surgery. Toric intraocular lenses can reliably reduce astigmatism and improve uncorrected vision in eyes with cataract and glaucoma. Copyright 2015, SLACK Incorporated.

  4. Phacoemulsification and implantation of an accommodating IOL after PRK.

    Science.gov (United States)

    Aslanides, loannis M; Plainis, Sotiris; Kumar, Vinod; Ginis, Harilaos

    2006-01-01

    To present a case of phacoemulsification and implantation of an accommodating intraocular lens (IOL) in a patient with cataract formation after previous refractive surgery. A 50-year-old man, who initially had photorefractive keratectomy to correct moderate myopia, developed a cataract in one eye. He subsequently underwent phacoemulsification and implantation of a 1CU accommodating IOL, as he wished to remain spectacle independent. The patient's distance vision was fully restored. However, accommodative function, which was assessed using subjective and novice objective techniques, was only partially restored. Although the accommodating IOL fully restored the patient's distance vision, accommodative function was only partially restored.

  5. Bioptics in sutureless intrascleral multifocal posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Pavlidis, Mitrofanis; de Ortueta, Diego; Scharioth, Gabor B

    2011-05-01

    To present a technique for sutureless fixation of a three-piece, multifocal, posterior chamber intraocular lens (IOL) in the ciliary sulcus. A 24-year-old woman presented with bilateral subluxation of the crystalline lens. Two straight sclerotomies were prepared with a 24-gauge cannula 2.0 mm from the limbus 180° apart from each other. The cannula was used to create a 2.0- to 3.0-mm tunnel parallel to the limbus starting from the sclerotomies. The leading haptic of the multifocal IOL was grasped at its tip with end-gripping, 25-gauge forceps and pulled through the sclerotomy. The forceps was used to introduce the IOL haptic into the scleral tunnel parallel to the limbus. Multifocal posterior chamber IOLs were stable and well centered. No postoperative complications occurred in the 16-month follow-up period. Preoperative astigmatism was corrected after IOL implantation with corneal wavefront-guided laser epithelial keratomileusis. Sutureless fixation of multifocal posterior chamber IOL haptics in a scleral tunnel parallel to the limbus can be successful, resulting in long-term centration and three-dimensional axial stability for optimal refractive results. If necessary, postoperative wavefront-guided refractive correction can be performed to optimize final refraction. Copyright 2011, SLACK Incorporated.

  6. Intraocular lens dislocation after whole-body vibration.

    Science.gov (United States)

    Vela, José I; Andreu, David; Díaz-Cascajosa, Jesús; Buil, José A

    2010-10-01

    We present 2 cases of intraocular lens (IOL) dislocation that appeared shortly after the patients exercised on a vibration platform. The first patient was a 71-year-old woman who presented with lens subluxation in her right eye and a complete posterior IOL dislocation in her left eye. The second case was a 62-year-old woman who presented with unilateral IOL dislocation within the capsular bag in her right eye. Timing from IOL implantation to dislocation was approximately 6 years and 4 years, respectively. Pars plana vitrectomy with removal of the dislocated IOL was performed in both patients. Whole-body vibration training has become increasingly popular as a form of exercise training. It reportedly may provide benefits in physical function and in some diseases, especially in older people. However, evidence-based protocols ensuring safety and efficacy in this population are lacking. We discuss vibration as a cause of late IOL dislocation. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  8. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  9. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  10. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  11. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  12. Analysis of a Thin Optical Lens Model

    Science.gov (United States)

    Ivchenko, Vladimir V.

    2011-01-01

    In this article a thin optical lens model is considered. It is shown that the limits of its applicability are determined not only by the ratio between the thickness of the lens and the modules of the radii of curvature, but above all its geometric type. We have derived the analytical criteria for the applicability of the model for different types…

  13. Mathematical Lens: How Much Can You Bench?

    Science.gov (United States)

    Bolognese, Chris A.

    2013-01-01

    "How Much Can You Bench?" appears in the "Mathematical Lens" section of "Mathematics Teacher." "Mathematical Lens" uses photographs as a springboard for mathematical inquiry and appears in every issue of "Mathematics Teacher." This month the mathematics behind the photograph includes finding areas…

  14. Plasma Lens for Muon and Neutrino Beams

    International Nuclear Information System (INIS)

    Kahn, S.A.; Korenev, S.; Bishai, M.; Diwan, M.; Gallardo, J.C.; Hershcovitch, A.; Johnson, B.M.

    2008-01-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-energy lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma for optimum focusing. The plasma lens is immersed in an additional solenoid magnetic field to facilitate the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. Plasma lenses have the additional advantage of negligible pion absorption and scattering by the lens material and reduced neutrino contamination during anti-neutrino running. Results of particle simulations using plasma lens will be presented

  15. LensEnt2: Maximum-entropy weak lens reconstruction

    Science.gov (United States)

    Marshall, P. J.; Hobson, M. P.; Gull, S. F.; Bridle, S. L.

    2013-08-01

    LensEnt2 is a maximum entropy reconstructor of weak lensing mass maps. The method takes each galaxy shape as an independent estimator of the reduced shear field and incorporates an intrinsic smoothness, determined by Bayesian methods, into the reconstruction. The uncertainties from both the intrinsic distribution of galaxy shapes and galaxy shape estimation are carried through to the final mass reconstruction, and the mass within arbitrarily shaped apertures are calculated with corresponding uncertainties. The input is a galaxy ellipticity catalog with each measured galaxy shape treated as a noisy tracer of the reduced shear field, which is inferred on a fine pixel grid assuming positivity, and smoothness on scales of w arcsec where w is an input parameter. The ICF width w can be chosen by computing the evidence for it.

  16. Bloqueio extraconal para facectomia com implante de lente intra-ocular: influência do fentanil associado ao anestésico local na qualidade do bloqueio e na analgesia pós-operatória Bloqueo extraconal para facectomia con implantación de lente intra-ocular: influencia del fentanil asociado al anestésico local en la calidad del bloqueo y en la analgesia pos-operatoria Extraconal block for cataract extraction surgery with implantation of intraocular lens: contribution of fentanyl associated to local anesthetics for quality of block and postoperative analgesia

    Directory of Open Access Journals (Sweden)

    Daniel Espada Lahoz

    2003-09-01

    de analgésicos con fentanil - 20,7%, en el uso de analgésicos con fentanil - 41,5%. CONCLUSIONES: En las condiciones de este estudio el fentanil mejoró la calidad del bloqueo cuanto a la motilidad del músculo recto medial y diminuyó la necesidad de analgésicos en el pos-operatorio.BACKGROUND AND OBJECTIVES: Loco-regional anesthesia for cataract extraction surgery offers as advantages minimum physiological changes, complete anesthesia, eye reflexes blockade, lower incidence of nausea and vomiting and shorter recovery time, in addition to postoperative analgesia. Continuous concern with blockade quality as well as with postoperative analgesia is responsibility of the anesthesiologist. This study aimed at evaluating whether fentanyl has contributed to blockade quality and postoperative analgesia in cataract extraction surgery with implantation of intraocular lens. METHODS: The association of fentanyl and 0.75% bupivacaine for eye blockade and postoperative analgesia was evaluated in 164 patients undergoing cataract extraction with implantation of intraocular lens (extracapsular technique. Patients were homogeneous in gender, demographics, operated eye, ASA physical status and Goldman’s cardiac risk index. Patients were randomly allocated in two groups (82 patients each: with or without fentanyl. Blockade quality was evaluated according to the following parameters: intraoperative pain; eyelid and/or eyeball movement; Bell’s reflex persistence; number of blocks needed to produce akinesia and surgeons evaluation of blockade. Postoperative analgesia was evaluated by patients’ request for additional postoperative analgesia. RESULTS: Results have shown that fentanyl has significantly improved medial rectus muscle blockade quality (with fentanyl - 17.1%; without fentanyl - 32.9% and has decreased postoperative analgesics consumption (analgesics with fentanyl - 20.7%; no analgesics with fentanyl - 41.5%. CONCLUSIONS: In the conditions of this study, fentanyl has

  17. Aphakia correction with retropupillary fixated iris-claw lens (Artisan – long-term results

    Directory of Open Access Journals (Sweden)

    Schallenberg M

    2013-12-01

    Full Text Available Maurice Schallenberg,1,2 Dirk Dekowski,1 Angela Hahn,1 Thomas Laube,1,3 Klaus-Peter Steuhl,1 Daniel Meller11Department of Ophthalmology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany; 2HELIOS Klinikum Wuppertal, Wuppertal, Germany; 3Zentrum für Augenheilkunde PD Dr Laube, Düsseldorf, GermanyPurpose: To evaluate the technique, safety, and efficacy of the retropupillary implantation of iris-claw intraocular lenses in a long-term follow-up study.Patients and methods: This retrospective study included 31 eyes of 31 patients who underwent an Artisan aphakic intraocular lens implantation between January 2006 and February 2011 at the University Hospital Essen, Essen, Germany and at the Zentrum für Augenheilkunde PD Dr Laube, Düsseldorf, Germany. Preoperative data collected included demographics, etiology of aphakia, previous surgeries, preoperative eye pathology, intraocular pressure, clinical signs of endothelial cell loss, and best corrected visual acuity. Operative data and postoperative outcomes included the best corrected visual acuity, lens position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, development of macular edema, and other complications.Results: Thirty-one patients were included. The mean follow-up was 25.2 months (range: 4–48 months. The mean best corrected visual acuity postoperatively was 0.64 logarithm of the minimum angle of resolution (logMAR and varied from 0 logMAR to 3 logMAR. Some patients had a low visual acuity preoperatively because of preoperative eye pathologies. In 22 patients the visual acuity improved, in two patients the visual acuity remained unchanged, and seven patients showed a decreased visual acuity. Complications were peaked pupils (n=10 and retinal detachment in one case. Four patients showed an iris atrophy and high intraocular pressure was observed only in one patient. Subluxation of the intraocular lens, endothelial cell loss, and

  18. Bottom-up fabrication of zwitterionic polymer brushes on intraocular lens for improved biocompatibility

    Directory of Open Access Journals (Sweden)

    Han Y

    2016-12-01

    Full Text Available Yuemei Han,1,* Xu Xu,1,* Junmei Tang,1,* Chenghui Shen,2 Quankui Lin,1,2 Hao Chen1,2 1School of Ophthalmology & Optometry, Eye Hospital, Wenzhou Medical University, 2Wenzhou Institute of Biomaterials and Engineering, Chinese Academy of Sciences, Wenzhou, People’s Republic of China *These authors contributed equally to this work Abstract: Intraocular lens (IOL is an efficient implantable device commonly used for treating cataracts. However, bioadhesion of bacteria or residual lens epithelial cells on the IOL surface after surgery causes postoperative complications, such as endophthalmitis or posterior capsular opacification, and leads to loss of sight again. In the present study, zwitterionic polymer brushes were fabricated on the IOL surface via bottom-up grafting procedure. The attenuated total reflection-Fourier transform infrared and contact angle measurements indicated successful surface modification, as well as excellent hydrophilicity. The coating of hydrophilic zwitterionic polymer effectively decreased the bioadhesion of lens epithelial cells or bacteria. In vivo intraocular implantation results showed good in vivo biocompatibility of zwitterionic IOL and its effectiveness against postoperative complications. Keywords: RAFT, surface modification, endophthalmitis, PCO, in vivo

  19. Comparison of a trifocal intraocular lens with a+3.0 D bifocal IOL: results of a prospective randomized clinical trial

    NARCIS (Netherlands)

    Jonker, S.M.R.; Bauer, N.J.C.; Makhotkina, N.Y.; Berendschot, T.T.J.M.; van den Biggelaar, F.J.H.M.; Nuijts, R.M.M.A.

    Purpose To compare visual outcomes in patients with cataract surgery and bilateral implantation of a trifocal or bifocal intraocular lens (IOL). Setting University Eye Clinic Maastricht, the Netherlands. Design Prospective randomized clinical trial. Methods Eyes with cataract and less than 1.0

  20. Lessons learned: wrong intraocular lens.

    Science.gov (United States)

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  1. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  2. Precision lens assembly with alignment turning system

    Science.gov (United States)

    Ho, Cheng-Fang; Huang, Chien-Yao; Lin, Yi-Hao; Kuo, Hui-Jean; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Chen, Fong-Zhi

    2017-10-01

    The poker chip assembly with high precision lens barrels is widely applied to ultra-high performance optical system. ITRC applies the poker chip assembly technology to the high numerical aperture objective lenses and lithography projection lenses because of its high efficiency assembly process. In order to achieve high precision lens cell for poker chip assembly, an alignment turning system (ATS) is developed. The ATS includes measurement, alignment and turning modules. The measurement module is equipped with a non-contact displacement sensor (NCDS) and an autocollimator (ACM). The NCDS and ACM are used to measure centration errors of the top and the bottom surface of a lens respectively; then the amount of adjustment of displacement and tilt with respect to the rotational axis of the turning machine for the alignment module can be determined. After measurement, alignment and turning processes on the ATS, the centration error of a lens cell with 200 mm in diameter can be controlled within 10 arcsec. Furthermore, a poker chip assembly lens cell with three sub-cells is demonstrated, each sub-cells are measured and accomplished with alignment and turning processes. The lens assembly test for five times by each three technicians; the average transmission centration error of assembly lens is 12.45 arcsec. The results show that ATS can achieve high assembly efficiency for precision optical systems.

  3. Corneal edema and permanent blue discoloration of a silicone intraocular lens by methylene blue.

    Science.gov (United States)

    Stevens, Scott; Werner, Liliana; Mamalis, Nick

    2007-01-01

    To report a silicone intraocular lens (IOL) stained blue by inadvertent intraoperative use of methylene blue instead of trypan blue and the results of experimental staining of various lens materials with different concentrations of the same dye. A "blue dye" was used to enhance visualization during capsulorhexis in a patient undergoing phacoemulsification with implantation of a three-piece silicone lens. Postoperatively, the patient presented with corneal edema and a discolored IOL. Various IOL materials were experimentally stained using methylene blue. Sixteen lenses (4 silicone, 4 hydrophobic acrylic, 4 hydrophilic acrylic, and 4 polymethylmethacrylate) were immersed in 0.5 mL of methylene blue at concentrations of 1%, 0.1%, 0.01%, and 0.001%. These lenses were grossly and microscopically evaluated for discoloration 6 and 24 hours after immersion. The corneal edema resolved within 1 month after the initial surgical procedure. After explantation, gross and microscopic analyses of the explanted silicone lens revealed that its surface and internal substance had been permanently stained blue. In the experimental study, all of the lenses except the polymethylmethacrylate lenses were permanently stained by methylene blue. The hydrophilic acrylic lenses showed the most intense blue staining in all dye concentrations. This is the first clinicopathological report of IOL discoloration due to intraocular use of methylene blue. This and other tissue dyes may be commonly found among surgical supplies in the operating room and due diligence is necessary to avoid mistaking these dyes for those commonly used during ocular surgery.

  4. CUSTOM OPTIMIZATION OF INTRAOCULAR LENS ASPHERICITY

    Science.gov (United States)

    Koch, Douglas D.; Wang, Li

    2007-01-01

    Purpose To investigate the optimal amount of ocular spherical aberration (SA) in an intraocular lens (IOL) to maximize optical quality. Methods In 154 eyes of 94 patients aged 40 to 80 years, implantation of aspheric IOLs was simulated with different amounts of SA to produce residual ocular SA from −0.30 μm to +0.30 μm. Using the VOL-CT program (Sarver & Associates, Carbondale, Illinois), corneal wavefront aberrations up to 6th order were computed from corneal topographic elevation data (Humphrey Atlas, Carl Zeiss Meditec, Inc, Dublin, California). Using the ZernikeTool program (Advanced Medical Optics, Inc, Santa Ana, California), the polychromatic point spread function with Stiles-Crawford effect was calculated for the residual ocular higher-order aberrations (HOAs, 3rd to 6th order, 6-mm pupil), assuming fully corrected 2nd-order aberrations. Five parameters were used to quantify optical image quality, and we determined the residual ocular SA at which the maximal image quality was achieved for each eye. Stepwise multiple regression analysis was performed to assess the predictors for optimal SA of each eye. Results The optimal SA varied widely among eyes. Most eyes had best image quality with low amounts of negative SA. For modulation transfer function volume up to 15 cycles/degree, the amount of optimal SA could be predicted based on other HOAs of the cornea with coefficient of multiple determination (R2) of 79%. Eight Zernike terms significantly contributed to the optimal SA in this model; the order of importance to optimal SA from most to least was: Z60, Z62, Z42, Z53, Z64, Z3−1, Z33, and Z31. For the other 4 measures of visual quality, the coefficients of determination varied from 32% to 63%. Conclusion The amount of ocular SA producing best image quality varied widely among subjects and could be predicted based on corneal HOAs. Selection of an aspheric IOL should be customized according to the full spectrum of corneal HOAs and not 4th-order SA alone

  5. Changes in blood pressure and sleep duration in patients with blue light-blocking/yellow-tinted intraocular lens (CHUKYO study).

    Science.gov (United States)

    Ichikawa, Kazuo

    2014-07-01

    Blood pressure and sleep duration may be influenced by retinal light exposure. Cataracts may exert such an influence by decreasing the transparency of the crystalline lens. A large-scale clinical study was conducted to examine changes in blood pressure and sleep duration after intraocular lens (IOL) implantation during cataract surgery and to investigate how different types of IOL influence the degree of these effects. Using a questionnaire, we collected information, including blood pressure measurement and sleep duration, from 1367 patients (1367 eyes) before IOL implantation, 1 week after IOL implantation and 1 month after IOL implantation. Systolic and diastolic blood pressures were significantly decreased in the total patient group after implantation. The decrease in systolic blood pressure 1 month after implantation was significantly more in patients who received a yellow-tinted IOL than it was in those who received an ultraviolet (UV) light-filtering IOL. The post-implantation sleep duration, including naps, became shorter in patients who had slept too much and became longer in those who had slept too little before IOL implantation. Our observations suggest that a yellow-tinted IOL is better for patients with high blood pressure than a UV light-filtering IOL. Furthermore, the yellow-tinted IOL is as good as the UV light-filtering IOL for improving sleep duration. A pale yellow-tinted IOL is likely to be superior to a moderate yellow-tinted IOL in terms of allowing patients to discriminate different colors. Thus, the pale yellow-tinted IOL appears to be better for patients than the UV light-filtering IOL and the moderate yellow-tinted IOL.

  6. Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline Lens.

    Science.gov (United States)

    Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam

    2017-12-01

    To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Design of a hyperbolic microwave metallic lens

    International Nuclear Information System (INIS)

    Uckan, T.

    1979-12-01

    Due to problems caused by multiple reflections in the cavity walls of the EBT fusion research device, the use of a horn becomes important for the directivity of waves in the millimetric range. An ordinary dielectric lens cannot be used because of plasma-wall interactions. Microwave metallic lenses, designed to focus the energy into a plane wave, can improve the directivity considerably. By implementing a 70-GHz standard-gain horn with a delay-type hyperbolic lens, which consists of a solid metallic disk with a number of equal size small holes has indicated a gain of 15 dB over the no lens case

  8. Accelerating convergence in automatic lens design

    International Nuclear Information System (INIS)

    Brixner, B.

    1981-01-01

    Among the various factors that slow lens optimization-insufficient performance targets, the absence of a unique solution, false local minima, a poorly scaled change vector, failure to find the optimum damping number, and failure to equalize the parameter gradients-the importance of parameter gradient equalization has been insufficiently recognized. Gradients can be approximately equalized by scaling the lens to a suitable size while it is being optimized. For best results, the size of the damping number should also be optimized during each iteration. If these two procedures are followed, scaling the change vector is usually not crucial. To illustrate the importance of parameter equalization, a lens optimization is analyzed

  9. Clinical outcomes of a new diffractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Baha Toygar

    2017-12-01

    Full Text Available AIM: To evaluate clinical outcomes after implantation of a new diffractive aspheric multifocal intraocular lens (IOL with +3.00 addition power. METHODS: This is a retrospective, consecutive case series of cataract patients who underwent bilateral implantation of the Optiflex MO/HF D012 (Moss Vision Inc. Ltd, London, UK multifocal IOL. Patients followed for 6mo were included in the study. Data on distance, intermediate and near visual acuity, refractive error [manifest spherical equivalent (MSE], contrast sensitivity, adverse events, subjective symptoms, spectacle independence and patient satisfaction [visual function questionnaire (VFQ-25 questionnaire] were retrieved from electronic medical records and analyzed. RESULTS: Forty eyes of 20 patients with a mean age of 66.7±8.5y (range: 53-82 were included in the study. Mean uncorrected distance, near and intermediate visual acuity remained stable through postoperative visits and was 0.19±0.19 logMAR, Jaeger 4 and Jaeger 3 respectively at the 6mo visit. At the end of postoperative 6mo, MSE was -0.14±0.42 diopters (D and 98% of the eyes were within 1.00 D of target refraction. Postoperative low contrast (10% visual acuity remained stable (P=0.54 through follow up visits with a mean of 0.35±0.17 logMAR at the 6mo visit. There were no reported adverse events. None of the patients reported subjective symptoms of halo or glare. Spectacle independence rate was 90%. Mean VFQ-25 questionnaire score was 93.5±6.12. CONCLUSION: The Optiflex MO/HF-DO12 IOL was safely implanted and successfully restored distance, intermediate and near visual acuity without impairing contrast sensitivity. High levels of spectacle independence were achieved at all distances including intermediate distance.

  10. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  11. 21 CFR 886.5844 - Prescription spectacle lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prescription spectacle lens. 886.5844 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5844 Prescription spectacle lens. (a) Identification. A prescription spectacle lens is a glass or plastic device that is a lens intended to be worn by...

  12. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...

  13. Net technique for intraocular lens support in aphakia without capsular support.

    Science.gov (United States)

    De Novelli, Fernando José; Neto, Theodomiro Lourenço Garrido; de Sena Rabelo, Gabriel; Blumer, Marcel Eduardo; Suzuki, Ricardo; Ghanem, Ramon Coral

    2017-01-01

    This paper describes a modified surgical technique for intraocular lens implantation in aphakic eyes with no capsular support. Retrospective case series. Seventeen eyes of 17 aphakic patients with no capsule support underwent intraocular lens (IOL) implantation using a standardized technique in which a net was created at the ciliary sulcus plane with two threads forming a net pattern. The net was used as support for the IOL. Follow-up ranged from 6 to 38 months, with an average of 23 months. In all cases, the IOL was safely implanted and remained stable during the follow-up. In 16 eyes, the IOL remained well centered; in one eye, slight decentration was observed. Distance-corrected visual acuity improved by a mean of 4 lines, from 1.13 (LogMAR) to 0.52 (P = 0.01). This technique might be especially useful in cases of insufficient capsular support associated with tissue loss or iris atrophy. In these cases, iris fixation is not feasible; thus, the only surgical alternative is IOL scleral fixation.

  14. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  15. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  16. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  17. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  18. AutoLens: Automated Modeling of a Strong Lens's Light, Mass and Source

    Science.gov (United States)

    Nightingale, J. W.; Dye, S.; Massey, Richard J.

    2018-05-01

    This work presents AutoLens, the first entirely automated modeling suite for the analysis of galaxy-scale strong gravitational lenses. AutoLens simultaneously models the lens galaxy's light and mass whilst reconstructing the extended source galaxy on an adaptive pixel-grid. The method's approach to source-plane discretization is amorphous, adapting its clustering and regularization to the intrinsic properties of the lensed source. The lens's light is fitted using a superposition of Sersic functions, allowing AutoLens to cleanly deblend its light from the source. Single component mass models representing the lens's total mass density profile are demonstrated, which in conjunction with light modeling can detect central images using a centrally cored profile. Decomposed mass modeling is also shown, which can fully decouple a lens's light and dark matter and determine whether the two component are geometrically aligned. The complexity of the light and mass models are automatically chosen via Bayesian model comparison. These steps form AutoLens's automated analysis pipeline, such that all results in this work are generated without any user-intervention. This is rigorously tested on a large suite of simulated images, assessing its performance on a broad range of lens profiles, source morphologies and lensing geometries. The method's performance is excellent, with accurate light, mass and source profiles inferred for data sets representative of both existing Hubble imaging and future Euclid wide-field observations.

  19. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  20. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K; Sanada, C; Tsukino, M [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  1. Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.

    Science.gov (United States)

    Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P

    2004-01-01

    The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.

  2. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  3. Characteristics of soft X-ray lens

    International Nuclear Information System (INIS)

    Qin Yi

    2007-12-01

    A soft X-lens was devised with waveguide X-ray optics of total external reflection (TER). The lens consists of a stack of 1 387 TER waveguides with inner diameter of 0.45 mm and outer diameter of 0.60 mm. With the help of plasma sources of soft X-ray radiation, high density of pure soft X-ray radiation (without plasma expansion fragments) with broad-band spectral range can be obtained at the focus of the lens. As laser-plasma is considered, the radiation density of 1.3 x 10 5 W/cm 2 is obtained, the transmission coefficient is 18.6%, the ratio of the density at the focus with and without the lens is 1000 and the radiation capture is 28.9 degree. The density of 0.5 TW/cm 2 can be obtained as far as Qiang-Guang I facility is considered. (authors)

  4. Gravitational lens effect and pregalactic halo objects

    International Nuclear Information System (INIS)

    Bontz, R.J.

    1979-01-01

    The changes in flux, position, and size of a distant extended (galaxy, etc.) source that result from the gravitational lens action of a massive opaque object are discussed. The flux increase is described by a single function of two parameters. One of these parameters characterizes the strength of the gravitational lens, the other describes the alignment of source and lens object. This function also describes the relative intensity of the images formed by lens. ( A similar formalism is discussed by Bourassa et al. for a point source). The formalism is applied to the problem of the galactic halo. It appears that a massive (10 1 2 M/sub sun/) spherical halo surrounding the visible part of the galaxy is consistent with the observable properties of extragalactic sources

  5. Discovery of two new gravitation lens systems

    International Nuclear Information System (INIS)

    Guertler, J.

    1988-01-01

    The discovery of new quasar and radio galaxy double images produced by the gravitation lens effect is reported. The light deflecting galaxies acting as gravitational lenses could be made visible by means of image processing procedures

  6. A Plasma Lens for Magnetron Sputtering

    International Nuclear Information System (INIS)

    Anders, Andre; Brown, Jeff

    2010-01-01

    A plasma lens, consisting of a solenoid and potential-defining ring electrodes, has been placed between a magnetron and substrates to be coated. Photography reveals qualitative information on excitation, ionization, and the transport of plasma to the substrate.

  7. The discovery of a gravitational lens

    International Nuclear Information System (INIS)

    Chaffee, F.H. Jr.

    1981-01-01

    A recently discovered pair of quasars turns out to be not a pair at all but two images of a single quasar formed by a gravitational lens: an elliptical galaxy halfway between the quasar and our own galaxy. (orig.) [de

  8. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  9. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  10. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  11. Role of Aquaporin 0 in lens biomechanics.

    Science.gov (United States)

    Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer

  12. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  13. Lens Design Using Group Indices of Refraction

    Science.gov (United States)

    Vaughan, A. H.

    1995-01-01

    An approach to lens design is described in which the ratio of the group velocity to the speed of light (the group index) in glass is used, in conjunction with the more familiar phase index of refraction, to control certain chromatic properties of a system of thin lenses in contact. The first-order design of thin-lens systems is illustrated by examples incorporating the methods described.

  14. Orbiting objective lens telescope system and method

    International Nuclear Information System (INIS)

    Crooks, J.W. Jr.

    1984-01-01

    A large objective lens is placed in a highly eccentric orbit about the earth. The orbit and orientation of the lens are carefully chosen so that it focuses light or other radiation from a preselected astronomical object into an image which slowly moves across the surface of the earth. A row of optical sensing units is located on the surface of the earth so that the image focused by the orbiting objective lens will travel substantially perpendicularly across the row during an observation. Output data generated from the sensing units may be multiplexed and fed to a real time processor which produces display signals. Each of the sensing units provides one scan line of the image being observed. The display signals are fed to a suitable display device which produces a picture of the preselected astronomical object. The objective lens may comprise a large flexible Fresnel zone plate or a flexible convex lens carried by a bicycle wheel-type supporting structure. The lens and supporting structure may be unfolded from compact cargo configurations and rotated after being placed into orbit

  15. Photon nanojet lens: design, fabrication and characterization

    International Nuclear Information System (INIS)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Chen, Yifang; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin

    2016-01-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect. (paper)

  16. Contact lens rehabilitation following repaired corneal perforations

    Science.gov (United States)

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  17. Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.

    Science.gov (United States)

    Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo

    2015-05-01

    Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.

  18. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-06-01

    Full Text Available Mun Yueh Faria,1 Nuno Ferreira,2 Eliana Neto,1 1Vitreo Retinal Department, 2Ophthalmology Department, Santa Maria Hospital, Lisbon, Portugal Objective: To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL in ectopia lentis in Marfan syndrome (MFS. Design: Retrospective study. Methods: Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA, and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years. Results: The average follow-up period was 6.66 months (range: 4–16 months. Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was –0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg and 16 mmHg (range: 12–18 mmHg, respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm, as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion: Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that

  19. Conservation through the economics lens.

    Science.gov (United States)

    Farley, Joshua

    2010-01-01

    Although conservation is an inherently transdisciplinary issue, there is much to be gained from examining the problem through an economics lens. Three benefits of such an approach are laid out in this paper. First, many of the drivers of environmental degradation are economic in origin, and the better we understand them, the better we can conserve ecosystems by reducing degradation. Second, economics offers us a when-to-stop rule, which is equivalent to a when-to-conserve rule. All economic production is based on the transformation of raw materials provided by nature. As the economic system grows in physical size, it necessarily displaces and degrades ecosystems. The marginal benefits of economic growth are diminishing, and the marginal costs of ecological degradation are increasing. Conceptually, we should stop economic growth and focus on conservation when the two are equal. Third, economics can help us understand how to efficiently and justly allocate resources toward conservation, and this paper lays out some basic principles for doing so. Unfortunately, the field of economics is dominated by neoclassical economics, which builds an analytical framework based on questionable assumptions and takes an excessively disciplinary and formalistic approach. Conservation is a complex problem, and analysis from individual disciplinary lenses can make important contributions to conservation only when the resulting insights are synthesized into a coherent vision of the whole. Fortunately, there are a number of emerging transdisciplines, such as ecological economics and environmental management, that are dedicated to this task.

  20. Peripheral Defocus of the Monkey Crystalline Lens With Accommodation in a Lens Stretcher

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; Ruggeri, Marco; Ho, Arthur; Gonzalez, Alex; Rowaan, Cor; Bernal, Andres; Arrieta, Esdras; Parel, Jean-Marie

    2018-01-01

    Purpose To characterize the peripheral defocus of the monkey crystalline lens and its changes with accommodation. Methods Experiments were performed on 15 lenses from 11 cynomolgus monkey eyes (age: 3.8–12.4 years, postmortem time: 33.5 ± 15.3 hours). The tissue was mounted in a motorized lens stretcher to allow for measurements of the lens in the accommodated (unstretched) and unaccommodated (stretched) states. A custom-built combined laser ray tracing and optical coherence tomography system was used to measure the paraxial on-axis and off-axis lens power for delivery angles ranging from −20° to +20° (in air). For each delivery angle, peripheral defocus was quantified as the difference between paraxial off-axis and on-axis power. The peripheral defocus of the lens was compared in the unstretched and stretched states. Results On average, the paraxial on-axis lens power was 52.0 ± 3.4 D in the unstretched state and 32.5 ± 5.1 D in the stretched state. In both states, the lens power increased with increasing delivery angle. From 0° to +20°, the relative peripheral lens power increased by 10.7 ± 1.4 D in the unstretched state and 7.5 ± 1.6 D in the stretched state. The change in field curvature with accommodation was statistically significant (P lens has greater curvature or relative peripheral power. Conclusions The cynomolgus monkey lens has significant accommodation-dependent curvature of field, which suggests that the lens asserts a significant contribution to the peripheral optical performance of the eye that also varies with the state of accommodation.

  1. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  2. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  3. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  4. Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique.

    Science.gov (United States)

    Yamane, Shin; Sato, Shimpei; Maruyama-Inoue, Maiko; Kadonosono, Kazuaki

    2017-08-01

    To report the clinical outcomes of a new technique for transconjunctival intrascleral fixation of an intraocular lens (IOL). Prospective, noncomparative, interventional case series. One hundred eyes of 97 consecutive patients with aphakia, dislocated IOL, or subluxated crystalline lens who underwent posterior chamber sutureless implantation of an IOL were studied. Two angled incisions parallel to the limbus were made by 30-gauge thin-wall needles. Haptics of an IOL were externalized with the needles and cauterized to make a flange of the haptics. The flange of the haptics were pushed back and fixed into the scleral tunnels. Best-corrected visual acuity (VA), corneal endothelial cell density, IOL tilt, and complications were determined. The IOLs were fixed with exact centration and axial stability. The mean preoperative best-corrected VA was 0.25 logarithm of the minimum angle of resolution (logMAR) units; after surgery, it improved significantly to 0.11 logMAR, 0.09 logMAR, 0.12 logMAR, and 0.04 logMAR at 6, 12, 24, and 36 months, respectively (P IOL tilt was 3.4°±2.5°. The postoperative complications included iris capture by the IOL in 8 eyes (8%), vitreous hemorrhage in 5 eyes (5%), and cystoid macular edema in 1 eye (1%). There were no incidents of postoperative retinal detachment, endophthalmitis, or IOL dislocation. We have developed a new technique for intrascleral IOL fixation. The flanged IOL fixation technique is a simple and minimally invasive method for achieving good IOL fixation with firm haptic fixation. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  5. Post-lens tear turbidity and visual quality after scleral lens wear.

    Science.gov (United States)

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p turbidity. © 2017 Optometry Australia.

  6. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was

  7. Disassembly of the lens fiber cell nucleus to create a clear lens: the p27 descent

    Science.gov (United States)

    The eye lens is unique among tissues: it is transparent, does not form tumors, and the majority of its cells degrade their organelles, including their cell nuclei. A mystery for over a century, there has been considerable recent progress in elucidating mechanisms of lens fiber cell denucleation (LFC...

  8. Nuclear magnetic resonance studies of lens transparency

    International Nuclear Information System (INIS)

    Beaulieu, C.F.

    1989-01-01

    Transparency of normal lens cytoplasm and loss of transparency in cataract were studied by nuclear magnetic resonance (NMR) methods. Phosphorus ( 31 P) NMR spectroscopy was used to measure the 31 P constituents and pH of calf lens cortical and nuclear homogenates and intact lenses as a function of time after lens enucleation and in opacification produced by calcium. Transparency was measured with laser spectroscopy. Despite complete loss of adenosine triphosphate (ATP) within 18 hrs of enucleation, the homogenates and lenses remained 100% transparent. Additions of calcium to ATP-depleted cortical homogenates produced opacification as well as concentration-dependent changes in inorganic phosphate, sugar phosphates, glycerol phosphorylcholine and pH. 1 H relaxation measurements of lens water at 200 MHz proton Larmor frequency studied temperature-dependent phase separation of lens nuclear homogenates. Preliminary measurements of T 1 and T 2 with non-equilibrium temperature changes showed a change in the slope of the temperature dependence of T 1 and T 2 at the phase separation temperature. Subsequent studies with equilibrium temperature changes showed no effect of phase separation on T 1 or T 2 , consistent with the phase separation being a low-energy process. 1 H nuclear magnetic relaxation dispersion (NMRD) studies (measurements of the magnetic field dependence of the water proton 1/T 1 relaxation rates) were performed on (1) calf lens nuclear and cortical homogenates (2) chicken lens homogenates, (3) native and heat-denatured egg white and (4) pure proteins including bovine γ-II crystallin bovine serum albumin (BSA) and myoglobin. The NMRD profiles of all samples exhibited decreases in 1/T 1 with increasing magnetic field

  9. Examining Wrong Eye Implant Adverse Events in the Veterans Health Administration With a Focus on Prevention: A Preliminary Report.

    Science.gov (United States)

    Neily, Julia; Chomsky, Amy; Orcutt, James; Paull, Douglas E; Mills, Peter D; Gilbert, Christina; Hemphill, Robin R; Gunnar, William

    2018-03-01

    The study goals were to examine wrong intraocular lens (IOL) implant adverse events in the Veterans Health Administration (VHA), identify root causes and contributing factors, and describe system changes that have been implemented to address this challenge. This study represents collaboration between the VHA's National Center for Patient Safety (NCPS) and the National Surgery Office (NSO). This report includes 45 wrong IOL implant surgery adverse events reported to established VHA NCPS and NSO databases between July 1, 2006, and June 31, 2014. There are approximately 50,000 eye implant procedures performed each year in the VHA. Wrong IOL implant surgery adverse events are reported by VHA facilities to the NCPS and the NSO. Two authors (A.C. and J.N.) coded the reports for event type (wrong lens or expired lens) and identified the primary contributing factor (coefficient κ = 0.837). A descriptive analysis was conducted, which included the reported yearly event rate. The main outcome measure was the reported wrong IOL implant surgery adverse events. There were 45 reported wrong IOL implant surgery adverse events. Between 2011 and June 30, 2014, there was a significant downward trend (P = 0.02, R = 99.7%) at a pace of -0.08 (per 10,000 cases) every year. The most frequently coded primary contributing factor was incomplete preprocedure time-out (n = 12) followed by failure to perform double check of preprocedural calculations based upon original data and implant read-back at the time the surgical eye implant was performed (n = 10). Preventing wrong IOL implant adverse events requires diligence beyond performance of the preprocedural time-out. In 2013, the VHA has modified policy to ensure double check of preprocedural calculations and implant read-back with positive impact. Continued analysis of contributing human factors and improved surgical team communication are warranted.

  10. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  11. Photosensitized oxidation in the ocular lens: evidence for photosensitizers endogenous to the human lens

    International Nuclear Information System (INIS)

    Zigler, J.S. Jr.; Goosey, J.D.

    1981-01-01

    Numerous investigators have attempted to associate near UV light exposure with various changes which occur to lens crystallins during aging and cataractogenesis. Recently it was shown that in vitro singlet oxygen mediated oxidation of lens crystallins produces effects very similar to those documented for crystallins from old or cataractous lenses and it was suggested that near UV photodynamic effects may play a major role in vivo in aging in the human lens. It has now been shown that certain oxidation products of tryptophan which have been identified in human lens can act as near UV photosensitizers, producing singlet oxygen. The insoluble protein fraction from human cataracts was shown to have the capacity to act as a photosensitizer. An age-related increase in photosensitizing capacity was also demonstrated in the soluble crystallins from human lens. These findings are discussed with respect to development of pigmented nuclear cataracts. (author)

  12. Optical integration of Pancharatnam-Berry phase lens and dynamical phase lens

    International Nuclear Information System (INIS)

    Ke, Yougang; Liu, Yachao; Zhou, Junxiao; Liu, Yuanyuan; Luo, Hailu; Wen, Shuangchun

    2016-01-01

    In the optical system, most elements such as lens, prism, and optical fiber are made of silica glass. Therefore, integrating Pancharatnam-Berry phase elements into silica glass has potential applications in the optical system. In this paper, we take a lens, for example, which integrates a Pancharatnam-Berry phase lens into a conventional plano-convex lens. The spin states and positions of focal points can be modulated by controlling the polarization states of the incident beam. The proposed lens has a high transmission efficiency, and thereby acts as a simple and powerful tool to manipulate spin photons. Furthermore, the method can be conveniently extended to the optical fiber and laser cavity, and may provide a route to the design of the spin-photonic devices.

  13. A case report of intraocular lens luxation with the capsular bag after vitrectomy.

    Science.gov (United States)

    Kawai, Kenji; Bando, Masayasu; Suzuki, Takahiro; Hayakawa, Kenji

    2004-04-01

    We experienced a case of intraocular lens (IOL) luxation with the capsular bag after vitrectomy. The case was a 66-year-old female in whom an IOL was implanted one year after surgery for giant tear retinal detachment using silicone oil. Four years after the implantation surgery, the patient suffered subluxation of the IOL with the capsular bag. Examinations of the luxated IOL with the capsular bag using a stereoscopic microscope confirmed the presence of silicone oil droplets between the capsule and the IOL. Adhesion of vitreous body residues was observed in the capsule. Luxation of the IOL was thought to be connected with chronic inflammation resulting from the use of silicone oil and repeated vitrectomy. In addition to examining pathological findings of luxated IOL, it would also be important in the future to identify the pathology of the capsular bag.

  14. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    Science.gov (United States)

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the

  15. [Representation and mathematical analysis of human crystalline lens].

    Science.gov (United States)

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  16. Development of Powerhouse Using Fresnel lens

    Directory of Open Access Journals (Sweden)

    Al-Dohani Nawar Saif

    2018-01-01

    Full Text Available Solar energy is an alternative source of renewable energy. Sultanate of Oman government showed initiation on utilization of solar energy for domestic and industrial applications. Fresnel lens is one of the methods to collect maximum energy by gathering heat of the sun in the concentrated form (using solar collectors. Earlier research work discloses that Fresnel lens gave better result in terms of power output and produces lower heat loss as compared to linear –parabolic solar collectors. In this work, development of a proto Fresnel lens power house was made to generate electricity. The focused heat from Fresnel lens was used to heat the molten salt in a heat exchanger to produce the steam. The generated steam was used to rotate the steam engine coupled to a generator. In the current work, a maximum power of 30 W was produced. In addition, comparative study was carried out regarding solar salts and heat exchanger materials to understand the Fresnel powerhouse performance. Overall the present study gave valuable information regarding usage of Fresnel lens for electricity generation in Oman.

  17. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  18. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  19. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    Science.gov (United States)

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  20. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2015-06-01

    Full Text Available AIM:To evaluate the prediction error in intraocular lens (IOL power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP.METHODS:Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany. In all cases, an adjusted IOL power (PIOLadj was calculated based on Gaussian optics using a variable keratometric index value (nkadj for the estimation of the corneal power (Pkadj and on a new value for ELP (ELPadj obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay Ⅰ.RESULTS:PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05. In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D and limits of agreement (of 1.47 and -1.61 D when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01 and was found to be dependent on axial length, anterior chamber depth and Pkadj.CONCLUSION:Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  1. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  2. Intraocular lens alignment from purkinje and Scheimpflug imaging.

    Science.gov (United States)

    Rosales, Patricia; De Castro, Alberto; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2010-11-01

    The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system images the reflections of an oblique collimated light source on the anterior cornea and anterior and posterior IOL surfaces and relies on the well supported assumption of the linearity of the Purkinje images with respect to IOL tilt and decentration. Scheimpflug imaging requires geometrical distortion correction and image processing techniques to retrieve the pupillary axis, IOL axis and pupil centre from the three-dimensional anterior segment image of the eye. Validation of the techniques using a physical eye model indicates that IOL tilt is estimated within an accuracy of 0.261 degree and decentration within 0.161 mm. Measurements on patients implanted with aspheric IOLs indicate that IOL tilt and decentration tend to be mirror symmetric between left and right eyes. The average tilt was 1.54 degrees and the average decentration was 0.21 mm. Simulated aberration patterns using custom models of the patients eyes, built using anatomical data of the anterior cornea and foveal position, the IOL geometry and the measured IOL tilt and decentration predict the experimental wave aberrations measured using laser ray tracing aberrometry on the same eyes. This reveals a relatively minor contribution of IOL tilt and decentration on the higher-order aberrations of the normal pseudophakic eye.

  3. [The effect of yellow filter intraocular lens on the macula after cataract phacoemulsification in patients with age macular degeneration].

    Science.gov (United States)

    Shpak, A A; Maliugin, B É; Fadeeva, T V

    2012-01-01

    Macula changes diagnosed with optical coherence tomography (OCT) within a year after cataract phacoemulsification (PE) with intraocular lens implantation with and without yellow filter are presented. 32 patients (36 eyes) with early stages of age macular degeneration (AMD) were included into the experimental group and 35 patients (36 eyes) served as controls. IOLs with yellow filter were implanted in 21 eyes, and in 15 cases IOLs without filter were used in each group. According to OCT data thickening of fovea and increasing of macula volume developed within 6 months after cataract PE. Implantation of yellow filter IOLs reduced the intensity of these changes after surgery in patients with AMD. The progression of early AMD into advanced stages within a year after PE was not observed.

  4. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  5. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  6. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  7. Terahertz lens made out of natural stone.

    Science.gov (United States)

    Han, Daehoon; Lee, Kanghee; Lim, Jongseok; Hong, Sei Sun; Kim, Young Kie; Ahn, Jaewook

    2013-12-20

    Terahertz (THz) time-domain spectroscopy probes the optical properties of naturally occurring solid aggregates of minerals, or stones, in the THz frequency range. Refractive index and extinction coefficient measurement reveals that most natural stones, including mudstone, sandstone, granite, tuff, gneiss, diorite, slate, marble, and dolomite, are fairly transparent for THz frequency waves. Dolomite in particular exhibits a nearly uniform refractive index of 2.7 over the broad frequency range from 0.1 to 1 THz. The high index of refraction allows flexibility in lens designing with a shorter accessible focal length or a thinner lens with a given focal length. Good agreement between the experiment and calculation for the THz beam profile confirms that dolomite has high homogeneity as a lens material, suggesting the possibility of using natural stones for THz optical elements.

  8. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  9. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  10. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  11. Characterization of lens based photoacoustic imaging system.

    Science.gov (United States)

    Francis, Kalloor Joseph; Chinni, Bhargava; Channappayya, Sumohana S; Pachamuthu, Rajalakshmi; Dogra, Vikram S; Rao, Navalgund

    2017-12-01

    Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  12. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  13. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  14. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  15. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  16. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  17. Analytic models of plausible gravitational lens potentials

    International Nuclear Information System (INIS)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2009-01-01

    Gravitational lenses on galaxy scales are plausibly modelled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sérsic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasising that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential. We also provide analytic formulae for the lens potentials of Sérsic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modelled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses

  18. Photonic crystal based polarization insensitive flat lens

    International Nuclear Information System (INIS)

    Turduev, M; Bor, E; Kurt, H

    2017-01-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a / λ   =  0.280 and a / λ   =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25 λ ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  19. Effect of infrared radiation on the lens

    Directory of Open Access Journals (Sweden)

    Aly Eman

    2011-01-01

    Full Text Available Background: Infrared (IR radiation is becoming more popular in industrial manufacturing processes and in many instruments used for diagnostic and therapeutic application to the human eye. Aim : The present study was designed to investigate the effect of IR radiation on rabbit′s crystalline lens and lens membrane. Materials and Methods: Fifteen New Zealand rabbits were used in the present work. The rabbits were classified into three groups; one of them served as control. The other two groups were exposed to IR radiation for 5 or 10 minutes. Animals from these two irradiated groups were subdivided into two subgroups; one of them was decapitated directly after IR exposure, while the other subgroup was decapitated 1 hour post exposure. IR was delivered from a General Electric Lamp model 250R 50/10, placed 20 cm from the rabbit and aimed at each eye. The activity of Na + -K + ATPase was measured in the lens membrane. Soluble lens proteins were extracted and the following measurements were carried out: estimation of total soluble protein, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE and Fourier transform infrared (FTIR spectroscopy. For comparison between multiple groups, analysis of variance was used with significance level set at P < 0.001. Results: The results indicated a change in the molecular weight of different lens crystalline accompanied with changes in protein backbone structure. These changes increased for the groups exposed to IR for 10 minutes. Moreover, the activity of Na + -K + ATPase significantly decreased for all groups. Conclusions: The protein of eye lens is very sensitive to IR radiation which is hazardous and may lead to cataract.

  20. ANALYTICAL SOLUTIONS OF SINGULAR ISOTHERMAL QUADRUPOLE LENS

    International Nuclear Information System (INIS)

    Chu Zhe; Lin, W. P.; Yang Xiaofeng

    2013-01-01

    Using an analytical method, we study the singular isothermal quadrupole (SIQ) lens system, which is the simplest lens model that can produce four images. In this case, the radial mass distribution is in accord with the profile of the singular isothermal sphere lens, and the tangential distribution is given by adding a quadrupole on the monopole component. The basic properties of the SIQ lens have been studied in this Letter, including the deflection potential, deflection angle, magnification, critical curve, caustic, pseudo-caustic, and transition locus. Analytical solutions of the image positions and magnifications for the source on axes are derived. We find that naked cusps will appear when the relative intensity k of quadrupole to monopole is larger than 0.6. According to the magnification invariant theory of the SIQ lens, the sum of the signed magnifications of the four images should be equal to unity, as found by Dalal. However, if a source lies in the naked cusp, the summed magnification of the left three images is smaller than the invariant 1. With this simple lens system, we study the situations where a point source infinitely approaches a cusp or a fold. The sum of the magnifications of the cusp image triplet is usually not equal to 0, and it is usually positive for major cusps while negative for minor cusps. Similarly, the sum of magnifications of the fold image pair is usually not equal to 0 either. Nevertheless, the cusp and fold relations are still equal to 0 in that the sum values are divided by infinite absolute magnifications by definition.

  1. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  2. Liquid lens: advances in adaptive optics

    Science.gov (United States)

    Casey, Shawn Patrick

    2010-12-01

    'Liquid lens' technologies promise significant advancements in machine vision and optical communications systems. Adaptations for machine vision, human vision correction, and optical communications are used to exemplify the versatile nature of this technology. Utilization of liquid lens elements allows the cost effective implementation of optical velocity measurement. The project consists of a custom image processor, camera, and interface. The images are passed into customized pattern recognition and optical character recognition algorithms. A single camera would be used for both speed detection and object recognition.

  3. Pulse transformer for the AA lithium lens

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  4. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  5. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  6. Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position

    Directory of Open Access Journals (Sweden)

    David P Piñero

    2015-01-01

    Full Text Available Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP. Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52-77 years and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (P IOLadj based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (n kadj for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELP adj . P IOLadj was compared to the real IOL power implanted (P IOLReal , calculated with the SRK-T formula and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between P IOLReal and P IOLadj when ELP adj was used (P = 0.10, with a range of agreement between calculations of 1.23 D. In contrast, P IOLReal was significantly higher when compared to P IOLadj without using ELP adj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

  7. Chapter 03: Correct use of a hand lens

    Science.gov (United States)

    Alex Wiedenhoeft

    2011-01-01

    A hand lens is a powerful tool for the identification of wood, but like all tools it must be used correctly to take full advantage of its powers. The hand lens has two main parts, a lens that magnifies the object of interest (generally we use 10X or 14X lenses in wood identification; a 14X lens is recommended for use with this manual) and a housing to hold and protect...

  8. Motorized injector-assisted intrascleral intraocular lens fixation.

    Science.gov (United States)

    Hung, Jia-Horung; Wang, Shih-Hao; Teng, Yu-Ti; Hsu, Sheng-Min

    2017-03-01

    For eyes with deficient capsular support, intraocular lens (IOL) implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (pIOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable. Copyright © 2017. Published by Elsevier Taiwan.

  9. Motorized injector-assisted intrascleral intraocular lens fixation

    Directory of Open Access Journals (Sweden)

    Jia-Horung Hung

    2017-03-01

    Full Text Available For eyes with deficient capsular support, intraocular lens (IOL implantation has long been a technical challenge. Recently, intrascleral fixation of the haptics of a three-piece posterior chamber IOL has become a popular option. In this procedure, externalization of the leading haptic during IOL injection is a stressful step. We present a modified technique to improve the ease and safety of this step. Our modified technique involves IOL injection with a motorized injector with several important modifications described here. With these modifications, a surgeon can easily maintain the correct orientation of the IOL in a well-controlled manner during IOL injection. The records of 13 patients who underwent this technique were retrospectively evaluated. Corrected-distance visual acuity improved significantly after surgery (p<0.05. No postoperative retinal detachment, endophthalmitis, IOL decentration, or vitreous hemorrhage was noted during the follow-up period. In conclusion, the motorized injector-assisted intrascleral IOL fixation technique is a safe and effective alternative to the conventional procedure. This technique makes the process of leading haptic externalization easier and more controllable.

  10. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Scharioth, Gabor B; Prasad, Som; Georgalas, Ilias; Tataru, Calin; Pavlidis, Mitrofanis

    2010-02-01

    To report the intermediate multicenter results of a technique of sutureless intrascleral fixation of a standard 3-piece posterior chamber intraocular lens (PC IOL) in the ciliary sulcus. Four European ophthalmology centers. A technique for sutureless intrascleral fixation of the haptics of a standard 3-piece PC IOL was retrospectively evaluated. The technique uses standardized maneuvers to fixate the PC IOL without need for special haptic architecture or preparation or haptic suturing. All patients having IOL implantation by the technique were evaluated for preoperative status (visual acuity, refractive error, preexisting ocular conditions, optical biometry), postoperative status, complications, and need for further surgery. The study evaluated 63 consecutive patients from 4 institutions (4 surgeons). The median follow-up was 7 months. Two dislocated PC IOLs (3.6%) were decentered; the other 61 IOLs (96.8%) were stable and well centered. There were no cases of recurrent dislocation, endophthalmitis, retinal detachment, or glaucoma. Fixation of PC IOL haptics in a limbus-parallel scleral tunnel provided exact centration and axial stability of the IOL and prevented distortion and subluxation in most cases. Copyright 2010 ASCRS and ESCRS. All rights reserved.

  11. Conduta cirúrgica na subluxação do cristalino Surgical approach to the subluxated lens

    Directory of Open Access Journals (Sweden)

    Nórton Souto Severo

    2004-02-01

    Full Text Available OBJETIVO: Apresentar 10 casos de subluxação de cristalino, secundários a trauma ou a síndrome de Marfan, discutindo o tratamento e os resultados obtidos. MÉTODOS: Foram estudados 10 olhos de 9 pacientes, 6 casos secundários a trauma contuso e 4 casos a síndrome de Marfan. A idade média foi de 48,9 ± 18,2 anos, com tempo de seguimento de 34,6 ± 11,6 meses (12 a 62 meses. Os pacientes foram submetidos à facectomia intracapsular (1 caso, extracapsular com capsulorrexe (1 caso, facoemulsificação sem LIO (1 caso, e facoemulsificação com implante de LIO (7 casos. Anéis expansores capsulares foram utilizados em 7 olhos. RESULTADOS: Houve melhora da acuidade visual em todos os casos durante o seguimento, exceto em um, em que houve descolamento de retina, 20 dias após o procedimento. CONCLUSÃO: A facectomia com implante de LIO em pacientes com cristalino subluxado é procedimento viável, principalmente com a facoemulsificação e o uso do anel expansor capsular, podendo melhorar bastante a acuidade visual e a qualidade de vida desses pacientes.PURPOSE: To evaluate 10 cases of subluxated lens due to trauma or Marfan syndrome, focussing on their treatment and the results. METHODS: Ten eyes of 9 patients were operated on due to lens subluxation. Six eyes were due to trauma and 4 eyes to Marfan syndrome. The mean age was 48.9 ± 18.2 years, and the follow-up period of 34.6 ± 11.6 months. Patients were submitted to intracapsular lens extraction (1 eye, extracapsular lens extraction (1 eye, phacoemulsification without IOL (1 eye, and phacoemulsification with IOL (7 eyes. Endocapsular rings were used in 7 eyes. RESULTS: Best-corrected visual acuity improved in all patients, except for one, who had a regmatogeneous retinal detachment, 20 days after surgery. CONCLUSION: Lens extraction with IOL implantation in subluxated lens patients has a good prognosis, especially with pha-coemulsification and endocapsular rings. With this approach, we were

  12. 21 CFR 886.1405 - Ophthalmic trial lens set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens set. 886.1405 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1405 Ophthalmic trial lens set. (a) Identification. An ophthalmic trial lens set is a device that is a set of lenses of various dioptric powers...

  13. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  14. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  15. 21 CFR 886.1380 - Diagnostic condensing lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...

  16. 21 CFR 886.1415 - Ophthalmic trial lens frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens frame. 886.1415 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1415 Ophthalmic trial lens frame. (a) Identification. An opthalmic trial lens frame is a mechanical device intended to hold trial lenses for vision...

  17. In vivo study of lens regeneration in Rana cyanophlyctis under ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... enhanced the percentage lens regeneration not only in young tadpoles but also in froglets. Lens regeneration ability ... Influence of vitamin A and ascorbic acid on lens regeneration in young, mature tadpoles and froglets of the frog Rana cyanophlyctis. Group .... ingested by macrophages. Dorsal iris cells ...

  18. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  19. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  20. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  1. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  2. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  3. Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction.

    Science.gov (United States)

    Kramer, Gregory D; Werner, Liliana; Neuhann, Tobias; Tetz, Manfred; Mamalis, Nick

    2015-09-01

    We describe the case of a patient who had cataract surgery with implantation of the hydrophilic acrylic Tetraflex accommodating intraocular lens (IOL), with subsequent development of capsulorhexis phimosis and in-the-bag IOL subluxation. Contraction of the capsular bag secondary to fibrosis resulted in significant anterior flexing of the lens haptic component. Explantation of the IOL-capsular bag complex was required 7 years after implantation. Histopathologic analysis demonstrated multiple areas of thick anterior subcapsular fibrosis. Pseudoexfoliative material was present throughout the surface of the lens capsule. Intraocular lenses manufactured from hydrophilic acrylic material are highly flexible and may be more susceptible to capsule contraction, even in the absence of predisposing ocular and systemic conditions. This case highlights the importance of developing guidelines regarding patient screening and selection for the appropriate use of accommodating and other highly flexible IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  5. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a

  6. Corneal ring infiltration in contact lens wearers

    Directory of Open Access Journals (Sweden)

    Seyed Ali Tabatabaei

    2017-01-01

    Full Text Available To report a case of atypical sterile ring infiltrates during wearing soft silicone hydrogel contact lens due to poor lens care. A 29-year-old woman presented with complaints of pain, redness, and morning discharge. She was wearing soft silicone hydrogel contact lens previously; her current symptoms began 1 week before presentation. On examination, best-corrected visual acuity was 20/40 in that eye. Slit-lamp examination revealed dense, ring-shaped infiltrate involving both the superficial and deep stromal layers with lucid interval to the limbus, edema of the epithelium, epithelial defect, and vascularization of the superior limbus. Cornea-specific in vivo laser confocal microscopy (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM, Heidelberg Engineering GmbH, Dossenheim, Germany revealed Langerhans cells and no sign of Acanthamoeba or fungal features, using lid scraping and anti-inflammatory drops; her vision completely recovered. We reported an atypical case of a sterile corneal ring infiltrate associated with soft contact lens wearing; smear, culture, and confocal microscopy confirmed a sterile inflammatory reaction.

  7. Lens Ray Diagrams with a Spreadsheet

    Science.gov (United States)

    González, Manuel I.

    2018-01-01

    Physicists create spreadsheets customarily to carry out numerical calculations and to display their results in a meaningful, nice-looking way. Spreadsheets can also be used to display a vivid geometrical model of a physical system. This statement is illustrated with an example taken from geometrical optics: images formed by a thin lens. A careful…

  8. Electronic states in a quantum lens

    International Nuclear Information System (INIS)

    Rodriguez, Arezky H.; Trallero-Giner, C.; Ulloa, S. E.; Marin-Antuna, J.

    2001-01-01

    We present a model to find analytically the electronic states in self-assembled quantum dots with a truncated spherical cap (''lens'') geometry. A conformal analytical image is designed to map the quantum dot boundary into a dot with semispherical shape. The Hamiltonian for a carrier confined in the quantum lens is correspondingly mapped into an equivalent operator and its eigenvalues and eigenfunctions for the corresponding Dirichlet problem are analyzed. A modified Rayleigh-Schro''dinger perturbation theory is presented to obtain analytical expressions for the energy levels and wave functions as a function of the spherical cap height b and radius a of the circular cross section. Calculations for a hard wall confinement potential are presented, and the effect of decreasing symmetry on the energy values and eigenfunctions of the lens-shape quantum dot is studied. As the degeneracies of a semicircular geometry are broken for b≠a, our perturbation approach allows tracking of the split states. Energy states and electronic wave functions with m=0 present the most pronounced influence on the reduction of the lens height. The method and expressions presented here can be straightforwardly extended to deal with more general Hamiltonians, including strains and valence-band coupling effects in Group III--V and Group II--VI self-assembled quantum dots

  9. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  10. Changes in monkey crystalline lens spherical aberration during simulated accommodation in a lens stretcher.

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; de Castro, Alberto; Durkee, Heather; Arrieta, Esdras; Marcos, Susana; Parel, Jean-Marie

    2015-02-10

    The purpose of this study was to quantify accommodation-induced changes in the spherical aberration of cynomolgus monkey lenses. Twenty-four lenses from 20 cynomolgus monkeys (Macaca fascicularis; 4.4-16.0 years of age; postmortem time 13.5 ± 13.0 hours) were mounted in a lens stretcher. Lens spherical aberration was measured in the unstretched (accommodated) and stretched (relaxed) states with a laser ray tracing system that delivered 51 equally spaced parallel rays along 1 meridian of the lens over the central 6-mm optical zone. A camera mounted below the lens was used to measure the ray height at multiple positions along the optical axis. For each entrance ray, the change in ray height with axial position was fitted with a third-order polynomial. The effective paraxial focal length and Zernike spherical aberration coefficients corresponding to a 6-mm pupil diameter were extracted from the fitted values. The unstretched lens power decreased with age from 59.3 ± 4.0 diopters (D) for young lenses to 45.7 ± 3.1 D for older lenses. The unstretched lens shifted toward less negative spherical aberration with age, from -6.3 ± 0.7 μm for young lenses to -5.0 ± 0.5 μm for older lenses. The power and spherical aberration of lenses in the stretched state were independent of age, with values of 33.5 ± 3.4 D and -2.6 ± 0.5 μm, respectively. Spherical aberration is negative in cynomolgus monkey lenses and becomes more negative with accommodation. These results are in good agreement with the predicted values using computational ray tracing in a lens model with a reconstructed gradient refractive index. The spherical aberration of the unstretched lens becomes less negative with age. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  11. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    Czech Academy of Sciences Publication Activity Database

    Konvalina, Ivo; Müllerová, Ilona

    2011-01-01

    Roč. 645, č. 1 (2011), s. 55-59 ISSN 0168-9002 R&D Projects: GA ČR GAP102/10/1410; GA AV ČR IAA100650902; GA MŠk ED0017/01/01 Institutional research plan: CEZ:AV0Z20650511 Keywords : cathode lens * compound objective lens * aberration coefficients * spot size * field calculations Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.207, year: 2011

  12. Preliminary Investigation of an Active PLZT Lens

    Science.gov (United States)

    Lightsey, W. D.; Peters, B. R.; Reardon, P. J.; Wong, J. K.

    2001-01-01

    The design, analysis and preliminary testing of a prototype Adjustable Focus Optical Correction Lens (AFOCL) is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro-optic lens. The AFOCL was developed to perform optical re-alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories (ULSSO). The AFOCL has potential application as an active optical component within a larger optical system. As such, information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sensed wavefront to the desired shape and location. While offering variable and rapid focussing capability (controlled wavefront manipulation) similar to liquid crystal based spatial light modulators (SLM), the AFOCL offers some potential advantages because it is a solid-state, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometer wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. The data was analyzed and compared to theoretical data available from computer-based models of the AFOCL.

  13. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  14. Gram negative bacteria and contact lens induced acute red eye

    Directory of Open Access Journals (Sweden)

    Sankaridurg Padmaja

    1996-01-01

    Full Text Available Two patients using hydrogel contact lenses on a daily wear schedule slept overnight with the lenses and woke up with a Contact Lens Induced Acute Red Eye (CLARE. The contact lenses recovered aseptically at the time of the event grew significant colonies of Pseudomonas aeruginosa and Aeromonas hydrophila in patient A and Pseudomonas aeruginosa and Serratia liquefaciens from patient B. Similar organisams from the contact lenses were recovered from the lens case and lens care solutions of patient B. In both the patients the condition resolved on discontinuation of lens wear. Patient compliance as a requirement for successful contact lens wear is highlighted with the illustration of these cases.

  15. Preliminary evaluation of an algorithm to minimize the power error selection of an aspheric intraocular lens by optimizing the estimation of the corneal power and the effective lens position

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2016-06-01

    Full Text Available AIM: To evaluate the refractive predictability achieved with an aspheric intraocular lens(IOLand to develop a preliminary optimized algorithm for the calculation of its power(PIOL.METHODS: This study included 65 eyes implanted with the aspheric IOL LENTIS L-313(Oculentis GmbHthat were divided into 2 groups: 12 eyes(8 patientswith PIOL≥23.0 D(group A, and 53 eyes(35 patientswith PIOLIOLadjwas calculated considering a variable refractive index for corneal power estimation, the refractive outcome obtained, and an adjusted effective lens position(ELPadjaccording to age and anatomical factors. RESULTS: Postoperative spherical equivalent ranged from -0.75 to +0.75 D and from -1.38 to +0.75 D in groups A and B, respectively. No statistically significant differences were found in groups A(P=0.64and B(P=0.82between PIOLadj and the IOL power implanted(PIOLReal. The Bland and Altman analysis showed ranges of agreement between PIOLadj and PIOLReal of +1.11 to -0.96 D and +1.14 to -1.18 D in groups A and B, respectively. Clinically and statistically significant differences were found between PIOLadj and PIOL obtained with Hoffer Q and Holladay I formulas(PCONCLUSION: The refractive predictability of cataract surgery with implantation of an aspheric IOL can be optimized using paraxial optics combined with linear algorithms to minimize the error associated to the estimation of corneal power and ELP.

  16. The influence of end of day silicone hydrogel daily disposable contact lens fit on ocular comfort, physiology and lens wettability.

    Science.gov (United States)

    Wolffsohn, James; Hall, Lee; Mroczkowska, Stephanie; Hunt, Olivia A; Bilkhu, Paramdeep; Drew, Tom; Sheppard, Amy

    2015-10-01

    To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Lens fit assessments were not different between brands (P>0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12h (P0.05). Movement-on-blink was unaffected by wear-time (F=0.403, P=0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r=-0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P>0.01). Among the lenses tested, objective lens fit changed between 8h and 12h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  17. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  18. The partial coherence modulation transfer function in testing lithography lens

    Science.gov (United States)

    Huang, Jiun-Woei

    2018-03-01

    Due to the lithography demanding high performance in projection of semiconductor mask to wafer, the lens has to be almost free in spherical and coma aberration, thus, in situ optical testing for diagnosis of lens performance has to be established to verify the performance and to provide the suggesting for further improvement of the lens, before the lens has been build and integrated with light source. The measurement of modulation transfer function of critical dimension (CD) is main performance parameter to evaluate the line width of semiconductor platform fabricating ability for the smallest line width of producing tiny integrated circuits. Although the modulation transfer function (MTF) has been popularly used to evaluation the optical system, but in lithography, the contrast of each line-pair is in one dimension or two dimensions, analytically, while the lens stand along in the test bench integrated with the light source coherent or near coherent for the small dimension near the optical diffraction limit, the MTF is not only contributed by the lens, also by illumination of platform. In the study, the partial coherence modulation transfer function (PCMTF) for testing a lithography lens is suggested by measuring MTF in the high spatial frequency of in situ lithography lens, blended with the illumination of partial and in coherent light source. PCMTF can be one of measurement to evaluate the imperfect lens of lithography lens for further improvement in lens performance.

  19. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  20. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  1. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  2. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  3. Characteristics of the retinal images of the eye optical systems with implanted intraocular lenses

    Science.gov (United States)

    Siedlecki, Damian; Zając, Marek; Nowak, Jerzy

    2007-04-01

    Cataract, or opacity of crystalline lens in the human eye is one of the most frequent reasons of blindness nowadays. Removing the pathologically altered crystalline lens and replacing it with artificial implantable intraocular lens (IOL) is practically the only therapy in this illness. There exist a wide variety of artificial IOL types on the medical market, differing in their material and design (shape). In this paper six exemplary models of IOL's made of PMMA, acrylic and silicone are considered. The retinal image quality is analyzed numerically on the basis of Liou-Brennan eye model with these IOL's inserted. Chromatic aberration as well as polychromatic Point Spread Function and Modulation Transfer Function are calculated as most adequate image quality measures. The calculations made with Zemax TM software show the importance of chromatic aberration correction.

  4. Ion implantation for microelectronics

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1977-01-01

    Ion implantation has proved to be a versatile and efficient means of producing microelectronic devices. This review summarizes the relevant physics and technology and assesses the advantages of the method. Examples are then given of widely different device structures which have been made by ion implantation. While most of the industrial application has been in silicon, good progress continues to be made in the more difficult field of compound semiconductors. Equipment designed for the industrial ion implantation of microelectronic devices is discussed briefly. (Auth.)

  5. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  6. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  7. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  8. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  9. Scleral lens use in dry eye syndrome.

    Science.gov (United States)

    Bavinger, J Clay; DeLoss, Karen; Mian, Shahzad I

    2015-07-01

    Dry eye syndrome can be difficult to manage in severe or refractory cases. In patients in whom traditional treatments have limited efficacy, alternative treatments may be considered for dry eye syndrome, including scleral lenses. The present review summarizes the evidence regarding scleral lens use in dry eye syndrome. Scleral lenses have become a viable option for severe dry eye syndrome, and have been shown to be efficacious and well tolerated, with most reports citing improved visual acuity and relief of symptoms. Currently, there are 18 manufacturers of scleral lenses, although published reports on scleral lenses primarily focus on the BostonSight PROSE and the Jupiter Lens. Scleral lenses are efficacious and well tolerated for use in severe dry eye syndrome. Further research is needed to compare different sizes and types of lenses, and to standardize outcome measures.

  10. Gravitational Lens Time Delays Using Polarization Monitoring

    Directory of Open Access Journals (Sweden)

    Andrew Biggs

    2017-11-01

    Full Text Available Gravitational lens time delays provide a means of measuring the expansion of the Universe at high redshift (and therefore in the ‘Hubble flow’ that is independent of local calibrations. It was hoped that many of the radio lenses found in the JVAS/CLASS survey would yield time delays as these were selected to have flat spectra and are dominated by multiple compact components. However, despite extensive monitoring with the Very Large Array (VLA, time delays have only been measured for three of these systems (out of 22. We have begun a programme to reanalyse the existing VLA monitoring data with the goal of producing light curves in polarized flux and polarization position angle, either to improve delay measurements or to find delays for new sources. Here, we present preliminary results on the lens system B1600+434 which demonstrate the presence of correlated and substantial polarization variability in each image.

  11. A Tribute to Dr. Willy Lens

    Directory of Open Access Journals (Sweden)

    Maarten Vansteenkiste

    2016-07-01

    Full Text Available Dr. Willy Lens, born on December 10th, 1943, passed away on August 29th, 2014. With his passing, the motivation community has lost a seminal member, a mentor, and a friend. Dr. Lens – a Fellow of the Association for Psychological Science and Founding Fellow of the American Educational Research Association – made fundamental contributions to the study of motivation both through his own work and through his caring and thoughtful mentorship of a large community of scholars. With this tribute, we want to honor Dr. Willy Lens’ significance to psychology and education as well as his positive influence, both personally and professionally, on the lives of dozens of scholars. With his contagious enthusiasm and caring mentorship, Willy was an example for our academic community and with this tribute we express our gratitude for the privilege to have collaborated with him.

  12. Hyperbolic metamaterial lens with hydrodynamic nonlocal response.

    Science.gov (United States)

    Yan, Wei; Mortensen, N Asger; Wubs, Martijn

    2013-06-17

    We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves of the free-electron plasma in the metal constituents. We derive the nonlocal corrections to the effective material parameters analytically, and illustrate the noticeable nonlocal effects on the dispersion curves numerically. As an application, we find that the focusing characteristics of a HMM lens in the local-response approximation and in the hydrodynamic Drude model can differ considerably. In particular, the optimal frequency for imaging in the nonlocal theory is blueshifted with respect to that in the local theory. Thus, to detect whether nonlocal response is at work in a hyperbolic metamaterial, we propose to measure the near-field distribution of a hyperbolic metamaterial lens.

  13. Dose limits to the eye lens

    International Nuclear Information System (INIS)

    Sion, N.

    2016-01-01

    Protecting the human body from the effects of ionizing radiation is essential to forestall stochastic effects and require placing limits on the effective dose. Dose limits on specific organs are also necessary to reduce the deterministic effects and tissue reactions. The standard for radiation protection was ISO 15382 (2002) which mainly dealt with beta radiation for nuclear power plant workers. Clearly an update is required to allow for new technology and the proliferative use of radiation in medical practices. There is a need for more explicit radiation monitoring to operators and staff. ICRP118 (International Commission on Radiological Protection), Ref. 1, evolved their recommendations to include eye lens doses as a follow on to their publication 103 and to focus on radiation exposures. It provides updated estimates of 'practical' threshold doses for tissue injury at the level of 1% incidence. This paper discusses the current status and the recommendation for a drastic reduction of the dose limit to the eye lens. (author)

  14. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  15. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  16. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  17. The Multi-Lens Array Architecture

    Science.gov (United States)

    2007-02-26

    slowly with respect to f, numerical integration using Simpson’s 1/3 Rule is a convenient method to evaluate Eq. 11. It can be shown the result can...quality of the paper. The author also has had stimulating discussions with Mr. David Curtis, Dr. Boris Tomasic and Dr. Peter Franchi . 24...REFERENCES [1] W. Rotman, P. Franchi , “Cylindrical Microwave Lens Antenna for Wideband Scanning Application”, Antennas and Prop. Int. Symposium, vol. 18

  18. Performance of a Be Refractive Lens

    International Nuclear Information System (INIS)

    Smither, R.K.; Khounsary, A.M.; Mancini, D.C.; Saleem, K. Abu

    2004-01-01

    The performance of a beryllium compound refractive lens (CRL) was tested in the energy range of 11.5 to 8.0 keV. The beryllium refractive lens consists of 50 aligned, 1-mm-diameter, hollow spheres in a solid block of beryllium, 30 mm x 20 mm x 55 mm. The minimum web between each hollow sphere was 0.10 mm. The measured focal length of the lens for x-rays close to the axis of the beam was 147.7 cm +/- 2.0 cm at 10 keV and 120.2 +/- 2.0 cm at 9.1 keV. These values agree well with the theoretical values of 146.6 cm and 121.4 cm, respectively. The diameter of the best focus obtained at 10 keV was 35 μm horizontal and 45 μm vertical. For the modified version of the lens used in the 9.1 keV experiment these values were 25 μm horizontal and 35 μm vertical. The x-ray beam cross section for the 10 keV and the 9.1 keV experiments were 0.50 mm x 0.50 mm and 0.30 mm x 0.30 mm, respectively. The enhancement of the flux (photons per sq. mm) was 50:1 at 10 keV and 80:1 in the 9.1 keV experiment

  19. LENS spectroscopy of low energy solar neutrinos

    CERN Document Server

    Schönert, S

    2001-01-01

    The LENS experiments will measure energy resolved sub-MeV solar electron-neutrinos ( nu /sub e/) in real time via inverse beta - transition populating an isomeric state in the daughter nuclei. The subsequent de-excitation provides a delayed coincidence tag which discriminates against background. A liquid scintillation detector loaded with 20 t of Yb would yield an event rate of 190 pp- and 175 /sup 7/Be neutrinos per year. Essential information on neutrino mixing and masses can be derived.

  20. THE BOSS EMISSION-LINE LENS SURVEY. IV. SMOOTH LENS MODELS FOR THE BELLS GALLERY SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Yiping [National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Bolton, Adam S.; Montero-Dorta, Antonio D.; Cornachione, Matthew A.; Zheng, Zheng; Brownstein, Joel R. [Department of Physics and Astronomy, University of Utah, 115 South 1400 East, Salt Lake City, UT 84112 (United States); Mao, Shude [Physics Department and Tsinghua Centre for Astrophysics, Tsinghua University, Beijing 100084 (China); Kochanek, Christopher S. [Department of Astronomy and Center for Cosmology and Astroparticle Physics, Ohio State University, Columbus, OH 43210 (United States); Pérez-Fournon, Ismael; Marques-Chaves, Rui [Instituto de Astrofísica de Canarias, C/Vía Láctea, s/n, E-38205 San Cristóbal de La Laguna, Tenerife (Spain); Oguri, Masamune [Research Center for the Early Universe, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ménard, Brice, E-mail: yiping.shu@nao.cas.cn [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2016-12-20

    We present Hubble Space Telescope F606W-band imaging observations of 21 galaxy-Ly α emitter lens candidates in the Baryon Oscillation Spectroscopic Survey Emission-Line Lens Survey (BELLS) for the GALaxy-Ly α EmitteR sYstems (BELLS GALLERY) survey. Seventeen systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately 0.55, while the lensed sources are Ly α emitters (LAEs) at redshifts from two to three. Although most of the lens systems are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thorough exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are, on average, 60% larger than those of the BELLS lenses because of the much higher source redshifts. This will allow for a detailed investigation of the radius evolution of the mass profile in ETGs. With the aid of the average ∼13× lensing magnification, the LAEs are frequently resolved into individual star-forming knots with a wide range of properties. They have characteristic sizes from less than 100 pc to several kiloparsecs, rest-frame far-UV apparent AB magnitudes from 29.6 to 24.2, and typical projected separations of 500 pc to 2 kpc.

  1. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  2. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  3. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  4. Thermal lens measurements in the cornea.

    Science.gov (United States)

    Venkatesh, S; Guthrie, S; Cruickshank, F R; Bailey, R T; Foulds, W S; Lee, W R

    1985-02-01

    Q-switched pulses from a neodymium/YAG (yttrium-aluminium-garnet) laser were passed through corneal discs taken from the enucleated eyes of three baboons and four rabbits. The time course of heat dissipation following absorption of laser energy by the tissue was studied with the use of a second continuous wave laser beam acting as a probe. It was found that the absorption of each neodymium/YAG pulse created a transient divergent lens within the cornea as theoretical considerations predicted. The relaxation time that characterised the decay of this thermal lens for a 1/e laser beam diameter of 2.0 mm was found to be 2.3 +/- 0.1 s (mean +/- standard error for 12 separate groups of measurements). Our results show that Q-switched laser pulses passing through apparently unaffected transparent tissues can induce thermal lens effects which persist for several seconds. The optical transfer of each pulse in a stream will be identical only if enough time is left between pulses for the tissues to return to their initial state. Therefore, when such laser pulses sharply focused to perform high precision intraocular surgery are used, thermal lensing in the transparent ocular media must limit the rate at which pulses can be usefully delivered.

  5. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  6. Metasurface axicon lens design at visible wavelengths

    Science.gov (United States)

    Alyammahi, Saleimah; Zhan, Qiwen

    2017-08-01

    The emerging field of metasurfaces is promising to realize novel optical devices with miniaturized flat format and added functionalities. Metasurfaces have been demonstrated to exhibit full control of amplitude, phase and polarization of electromagnetic waves. Using the metasurface, the wavefront of light can be manipulated permitting new functionalities such as focusing and steering of the beams and imaging. One optical component which can be designed using metasurfaces is the axicon. Axicons are conical lenses used to convert Gaussian beams into nondiffraction Bessel beams. These unique devices are utilized in different applications ranging from optical trapping and manipulation, medical imaging, and surgery. In this work, we study axicon lens design comprising of planar metasurfaces which generate non-diffracting Bessel beams at visible wavelengths. Dielectric metasurfaces have been used to achieve high efficiency and low optical loss. We measured the spot size of the resulted beams at different planes to demonstrate the non-diffraction properties of the resulted beams. We also investigated how the spot size is influenced by the axicon aperture. Furthermore, we examined the achromatic properties of the designed axicon. Comparing with the conventional lens, the metasurface axicon lens design enables the creation of flat optical device with wide range of depth of focus along its optical axis.

  7. Evaluation of lens dose in medulloblastoma radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, F.L.; Vilela, E.C.; Sousa, S.A; Lima, F.F. de

    2007-01-01

    The improvement of the applied radiotherapy techniques in the cranial-spinal therapy, which is used in the cases of medulloblastoma, aims the reduction of the risks of future damages in enclosed critical agencies in the irradiation fields. This work aims to evaluate the lens doses due two common techniques used in medulloblastoma radiotherapy. For this, thermoluminescent dosimeters, previously calibrated, were located in an anthropomorphic phantom (ALDERSON - RANDON Laboratory), in the tumor and lens positions. The employed techniques were as following: (1) angled fields technique and (2) half-beam block technique. The phantom was irradiated five times in each technique with two lateral opposed fields in the brain with a total prescribed dose of 1.5 Gy, followed of two posterior spinal fields with the same prescribed dose, using a 6MV accelerator. The results showed that the doses in the first technique were 0.10 +- 0,04 Gy and, in second one, 0.09 +- 0,02 Gy. It was observed that, independent of the employed technique, the lens doses practically are the same. (author)

  8. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  9. Human lens colouration, age and cataract

    International Nuclear Information System (INIS)

    Truscott, R.J.W.; Garner, B.; Hood, B.

    1999-01-01

    Full text: The human lens biosynthesises UV filter compounds which effectively remove light in the 300-400nm band. These chemicals are present either as an aid to visual acuity, or to filter out damaging UV radiation. The primate UV filters are 3-hydroxykynurenine analogues derived from the metabolism of tryptophan. We have recently demonstrated that these endogenous UV filters are not innocuous, but are in fact capable of binding to proteins, including the crystalline proteins which make up the bulk of the lens. Thus, over time, the levels of protein - bound UV filters increase and this results in the human lens becoming progressively more yellow as we age. This colouration affects our colour vision and it may also be responsible for the brown colour of lenses which is the hallmark of age-related nuclear cataract. An understanding of the intrinsic instability of the endogenous UV filters, combined with changes in the internal transport of these and other small molecular weight compounds including antioxidants, such as glutathione, is allowing us to gain an insight into the processes responsible for the development of age-related cataract: the major cause of world blindness

  10. Compound refractive X-ray lens

    Science.gov (United States)

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  11. Intraocular lens calculations in atypical eyes

    Directory of Open Access Journals (Sweden)

    Aazim A Siddiqui

    2017-01-01

    Full Text Available Cataract surgery is the most performed surgical procedure in the field of ophthalmology. The process of intraocular lens (IOL calculations is a critical step to achieving successful outcomes. Many IOL formulae exist to guide surgeons through the difficult process of picking the most appropriate lens to achieve a certain target refraction. However, these formulae reach within 0.50 diopters of the target refraction only 75% of the time, leaving 25% of the eyes with a significant refractive surprise. A literature review was performed to investigate all the relevant published material on the history, progress, and recent advancements of IOL calculations. Based on this review, the appropriate history, evolution, progress, limitations, and recent advancements are analyzed and explained. Although the modern IOL formulae and biometric devices perform well for average eyes, they are suboptimal for eyes with atypical biometric parameters and also those that are postrefractive and keratoconic. There has not been a single, perfect formula that can resolve the complexities of this process. Various methods of formula optimization and newer generation of IOL formulae and devices may hold the key to improving outcomes in both typical and atypical eyes. These solutions minimize refractive error by introducing new input parameters and complex mathematical techniques to better estimate postoperative lens position.

  12. Two families of astrophysical diverging lens models

    Science.gov (United States)

    Er, Xinzhong; Rogers, Adam

    2018-03-01

    In the standard gravitational lensing scenario, rays from a background source are bent in the direction of a foreground lensing mass distribution. Diverging lens behaviour produces deflections in the opposite sense to gravitational lensing, and is also of astrophysical interest. In fact, diverging lensing due to compact distributions of plasma has been proposed as an explanation for the extreme scattering events that produce frequency-dependent dimming of extragalactic radio sources, and may also be related to the refractive radio wave phenomena observed to affect the flux density of pulsars. In this work we study the behaviour of two families of astrophysical diverging lenses in the geometric optics limit, the power law, and the exponential plasma lenses. Generally, the members of these model families show distinct behaviour in terms of image formation and magnification, however the inclusion of a finite core for certain power-law lenses can produce a caustic and critical curve morphology that is similar to the well-studied Gaussian plasma lens. Both model families can produce dual radial critical curves, a novel distinction from the tangential distortion usually produced by gravitational (converging) lenses. The deflection angle and magnification of a plasma lens vary with the observational frequency, producing wavelength-dependent magnifications that alter the amplitudes and the shape of the light curves. Thus, multiwavelength observations can be used to physically constrain the distribution of the electron density in such lenses.

  13. Radiation dose to the lens and cataract formation

    International Nuclear Information System (INIS)

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M.

    1993-01-01

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab

  14. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  15. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  16. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    Science.gov (United States)

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  17. Contact lenses fitting after intracorneal ring segments implantation in keratoconus

    Directory of Open Access Journals (Sweden)

    Luciane Bugmann Moreira

    2013-08-01

    Full Text Available PURPOSE: Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS: Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intolerants to contact lenses prior to intracorneal implantation. Visual acuity analysis was done by conversion of Snellen to logMAR scales. The comfort was evaluated according subjective questioning of good, medium or poor comfort. RESULTS: Nineteen patients were included in the study. Two patients (10.5% did not achieved good comfort with contact lenses and underwent penetrating keratoplasties. All the others 17 patients showed good or medium comfort. Four rigid gas-permeable contact lenses were fitted, one piggyback approach, 3 toric soft contact lenses, 2 soft lenses specially design for keratoconus and 7 disposable soft lenses. The average visual acuity improved from 0.77 ± 0.37 to 0.19 ± 0.13 logMAR units after contact lenses fitting. CONCLUSION: Contact lens fitting after intracorneal ring is possible, provides good comfort, improves visual acuity, and therefore, may postpone the need for penetrating keratoplasty.

  18. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    Science.gov (United States)

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  19. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  20. Glued intrascleral fixation of posterior chamber intraocular lens in children.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Prakash, Dimple; Prakash, Gaurav; Jacob, Soosan; Agarwal, Athiya

    2012-04-01

    To evaluate the short-term results of glued intrascleral fixation of posterior chamber intraocular lens (glued IOL) in children without adequate capsular support. Noncomparative retrospective observational case series. Institutional practice. Forty-one eyes of 33 children who underwent glued IOL implantation were retrospectively evaluated. The indications were postsurgical aphakia, subluxated cataract, ectopia lentis, traumatic subluxation, and decentered IOL. Visual acuity (VA), endothelial cell changes, intraoperative and postoperative complications. The mean age at the time of glued IOL was 10.7±3.6 years (range 5-15). The mean duration of follow-up after surgery was 17.5±8.5 months (range 12-36). The mean postoperative best spectacle-corrected visual acuity (BCVA in decimal equivalent) was 0.43±0.33 and there was significant change noted (P20/60 BCVA was obtained in 17.1% and 46.3% of eyes respectively. BCVA improvement more than 1 line was seen in 22 eyes (53.6%). The mean postoperative refraction was myopic (-1.19±0.7 diopters [D]) in 19 eyes and hyperopic (+1.02±0.7 D) in 22 eyes. The mean endothelial loss was 4.13% (range 1.3%-5.94%). The 3 causes of reduced BCVA were the preexisting corneal, retinal pathology, and amblyopia. Postoperative complications included optic capture in 1 eye (2.4%), macular edema in 2 eyes (4.8%), and clinical decentration in 2 eyes (4.8%). There was no postoperative retinal detachment, IOL dislocation, endophthalmitis, or glaucoma. Short-term results in children after glued IOL were favorable, with a low rate of complications. However, regular follow-ups are required since long-term risks are unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Multipoint photonic doppler velocimetry using optical lens elements

    Science.gov (United States)

    Frogget, Brent Copely; Romero, Vincent Todd

    2014-04-29

    A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

  2. Measuring and correcting aberrations of a cathode objective lens

    International Nuclear Information System (INIS)

    Tromp, R.M.

    2011-01-01

    In this paper I discuss several theoretical and practical aspects related to measuring and correcting the chromatic and spherical aberrations of a cathode objective lens as used in Low Energy Electron Microscopy (LEEM) and Photo Electron Emission Microscopy (PEEM) experiments. Special attention is paid to the various components of the cathode objective lens as they contribute to chromatic and spherical aberrations, and affect practical methods for aberration correction. This analysis has enabled us to correct a LEEM instrument for the spherical and chromatic aberrations of the objective lens. -- Research highlights: → Presents a comprehensive theory of the relation between chromatic aberration and lens current in a cathode objective lens. → Presents practical methods for measuring both spherical and chromatic aberrations of a cathode objective lens. → Presents measurements of these aberrations in good agreement with theory. → Presents practical methods for measuring and correcting these aberrations with an electron mirror.

  3. Forensic Analysis of a Contact Lens in a Murder Case.

    Science.gov (United States)

    Zwerling, Charles S

    2016-03-01

    Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations. © 2016 American Academy of Forensic Sciences.

  4. The neutron silicon lens. An update of the thermal neutron lens results

    International Nuclear Information System (INIS)

    Johnson, M.W.; Daymond, M.R.

    2001-01-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  5. The neutron silicon lens. An update of the thermal neutron lens results

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, M.W.; Daymond, M.R. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire (United Kingdom)

    2001-03-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  6. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    Science.gov (United States)

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  7. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  8. Application of lens capsules tension reducing capsulorhexis and conventional capsulorhexis in the white cataract phacoemulsification

    Directory of Open Access Journals (Sweden)

    Rong-Feng Liu

    2017-09-01

    Full Text Available Objective: To explore the clinical effect of lens capsules tension reducing capsulorhexis and conventional capsulorhexis in the white cataract phacoemulsification. Methods: A total of 68 patients (76 eyes with white cataract who were admitted in our hospital from June, 2011 to June, 2016 were included in the study and divided into the experiment group (n=34, 36 eyes and the control group (n=34, 40 eyes according to the difference of intraoperative capsulorhexis. All the patients were performed with cataract phacoemulsification in combined with intraocular lens implantation. The patients in the experiment group were performed with lens capsules tension reducing capsulorhexis, while the patients in the control group were performed with conventional capsulorhexis. The integrity of the anterior capsule capsulorhexis, the degree of corneal endothelium edema, the intraocular lens deviation, uncorrected visual acuity, and corneal endothelial cell count in the two groups were compared. Results: A total of 34 eyes (94.44% in the experiment group and 35 eyes (87.50% in the control group successfully completed continuous annular capsulorhexis, and there was no significant difference between the 2 groups. The number of patients whose uncorrected visual acuity was greater than 0.5 increased 1 d-6 months after operation, and that in the experiment group was significantly higher than that in the control group. The difference of intraocular lens deviation rates between the 2 groups at different times after operation was not significant. The corneal endothelial cell count 1 d-6 months after operation in the 2 groups was significantly decreased when compared with before operation, but the difference between the 2 groups was not significant. The number of eyes without edema in the experiment group 1d after operation was significantly higher than that in the control group, and the number of eyes with grade Ⅱ edema was significantly less than that in the control

  9. Design of a nonimaging Fresnel lens for solar concentrators

    Energy Technology Data Exchange (ETDEWEB)

    Leutz, R.; Akisawa, Atushi; Kashiwagi, Takao [Tokyo University of Agriculture and Technology (Japan). Dept. of Mechanical Systems Engineering; Suzuki, Akio [UNESCO, Paris (France)

    1999-04-01

    An optimum convex shaped nonimaging Fresnel lens is designed following the edge ray principle. The lens is evaluated by tracing rays and calculating a projective optical concentration ratio. This Fresnel lens is intended for use in evacuated tube type solar concentrators, generating mid-temperature heat to drive sorption cycles, or provide industrial process heat. It can also be used along with a secondary concentrator in photovoltaic applications. (author)

  10. Freeform Lens Design for Scattering Data with General Radiant Fields

    Science.gov (United States)

    Gutiérrez, Cristian E.; Sabra, Ahmad

    2018-05-01

    We show the existence of a lens, when its lower face is given, such that it refracts radiation emanating from a planar source, with a given field of directions, into the far field that preserves a given distribution of energies. Conditions are shown under which the lens obtained is physically realizable. It is shown that the upper face of the lens satisfies a pde of Monge-Ampère type.

  11. Recurrent uveitis and pigment dispersion in an eye with in-the-bag acrylic foldable intraocular lens.

    Science.gov (United States)

    Thakur, Monica; Bhatia, Prashant; Chandrasekhar, Garudadri; Senthil, Sirisha

    2016-02-26

    Phacoemulsification with in-the-bag intraocular lens (IOL) implantation is the standard procedure for cataract surgery. Pigment dispersion and uveitis can result when an IOL is placed in the sulcus. We report a case of a 64-year-old woman, with pigmentary glaucoma, who developed recurrent uveitis following uneventful cataract surgery and an in-the-bag hydrophobic acrylic IOL implant. Recurrent uveitis did not subside despite use of topical steroids over 3 months. Dilated examination revealed capsulophimosis with anterior dislocation of the IOL haptic. The mechanical trauma to the iris due to the displaced haptic was implicated as the cause of recurrent uveitis, which completely resolved after capsular excision and IOL repositioning. This case illustrates a rare cause of recurrent uveitis due to IOL haptic dislocation following severe capsulophimosis. 2016 BMJ Publishing Group Ltd.

  12. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  13. Wide-range tunable magnetic lens for tabletop electron microscope

    International Nuclear Information System (INIS)

    Chang, Wei-Yu; Chen, Fu-Rong

    2016-01-01

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  14. Effects of Coupling Lens on Optical Refrigeration of Semiconductors

    International Nuclear Information System (INIS)

    Kai, Ding; Yi-Ping, Zeng

    2008-01-01

    Optical refrigeration of semiconductors is encountering efficiency difficulties caused by nonradiative recombination and luminescence trapping. A commonly used approach for enhancing luminescence efficiency of a semiconductor device is coupling a lens with the device. We quantitatively study the effects of a coupling lens on optical refrigeration based on rate equations and photon recycling, and calculated cooling efficiencies of different coupling mechanisms and of different lens materials. A GaAs/GaInP heterostructure coupled with a homo-epitaxial GaInP hemispherical lens is recommended. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  15. Lens regeneration in axolotl: new evidence of developmental plasticity

    Directory of Open Access Journals (Sweden)

    Suetsugu-Maki Rinako

    2012-12-01

    Full Text Available Abstract Background Among vertebrates lens regeneration is most pronounced in newts, which have the ability to regenerate the entire lens throughout their lives. Regeneration occurs from the dorsal iris by transdifferentiation of the pigment epithelial cells. Interestingly, the ventral iris never contributes to regeneration. Frogs have limited lens regeneration capacity elicited from the cornea during pre-metamorphic stages. The axolotl is another salamander which, like the newt, regenerates its limbs or its tail with the spinal cord, but up until now all reports have shown that it does not regenerate the lens. Results Here we present a detailed analysis during different stages of axolotl development, and we show that despite previous beliefs the axolotl does regenerate the lens, however, only during a limited time after hatching. We have found that starting at stage 44 (forelimb bud stage lens regeneration is possible for nearly two weeks. Regeneration occurs from the iris but, in contrast to the newt, regeneration can be elicited from either the dorsal or the ventral iris and, occasionally, even from both in the same eye. Similar studies in the zebra fish concluded that lens regeneration is not possible. Conclusions Regeneration of the lens is possible in the axolotl, but differs from both frogs and newts. Thus the axolotl iris provides a novel and more plastic strategy for lens regeneration.

  16. Adaptive mechanical-wetting lens actuated by ferrofluids

    Science.gov (United States)

    Cheng, Hui-Chuan; Xu, Su; Liu, Yifan; Levi, Shoshana; Wu, Shin-Tson

    2011-04-01

    We report an adaptive mechanical-wetting lens actuated by ferrofluids. The ferrofluids works like a piston to pump liquids in and out from the lens chamber, which in turn reshapes the lens curvature and changes the focal length. Both positive and negative lenses are demonstrated experimentally. The ferrofluid-actuated mechanical-wetting lens exhibits some attractive features, such as high resolution, fast response time, low power consumption, simple structure and electronic control, weak gravity effect, and low cost. Its potential applications in medical imaging, surveillance, and commercial electronics are foreseeable.

  17. Particle swarm optimization applied to automatic lens design

    Science.gov (United States)

    Qin, Hua

    2011-06-01

    This paper describes a novel application of Particle Swarm Optimization (PSO) technique to lens design. A mathematical model is constructed, and merit functions in an optical system are employed as fitness functions, which combined radiuses of curvature, thicknesses among lens surfaces and refractive indices regarding an optical system. By using this function, the aberration correction is carried out. A design example using PSO is given. Results show that PSO as optical design tools is practical and powerful, and this method is no longer dependent on the lens initial structure and can arbitrarily create search ranges of structural parameters of a lens system, which is an important step towards automatic design with artificial intelligence.

  18. Lens transmission measurement for an absolute radiation thermometer

    International Nuclear Information System (INIS)

    Hao, X.; Yuan, Z.; Lu, X.

    2013-01-01

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10 −3 at 633 nm and 900 nm, respectively

  19. Wide-range tunable magnetic lens for tabletop electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Yu; Chen, Fu-Rong, E-mail: fchen1@me.com

    2016-12-15

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  20. Flat dielectric metasurface lens array for three dimensional integral imaging

    Science.gov (United States)

    Zhang, Jianlei; Wang, Xiaorui; Yang, Yi; Yuan, Ying; Wu, Xiongxiong

    2018-05-01

    In conventional integral imaging, the singlet refractive lens array limits the imaging performance due to its prominent aberrations. Different from the refractive lens array relying on phase modulation via phase change accumulated along the optical paths, metasurfaces composed of nano-scatters can produce phase abrupt over the scale of wavelength. In this letter, we propose a novel lens array consisting of two neighboring flat dielectric metasurfaces for integral imaging system. The aspherical phase profiles of the metasurfaces are optimized to improve imaging performance. The simulation results show that our designed 5 × 5 metasurface-based lens array exhibits high image quality at designed wavelength 865 nm.