WorldWideScience

Sample records for cold leg thermocouple

  1. On exact solutions and numerics for cold, shallow, and thermocoupled ice sheets

    CERN Document Server

    Bueler, E; Brown, Jed; Bueler, Ed

    2006-01-01

    This three section report can be regarded as an extended appendix to (Bueler, Brown, and Lingle 2006). First we give the detailed construction of an exact solution to a standard continuum model of a cold, shallow, and thermocoupled ice sheet. The construction is by calculation of compensatory accumulation and heat source functions which make a chosen pair of functions for thickness and temperature into exact solutions of the coupled system. The solution we construct here is ``TestG'' in (Bueler and others, 2006) and the steady state solution ``Test F'' is a special case. In the second section we give a reference C implementation of these exact solutions. In the last section we give an error analysis of a finite difference scheme for the temperature equation in the thermocoupled model. The error analysis gives three results, first the correct form of the Courant-Friedrichs-Lewy (CFL) condition for stability of the advection scheme, second an equation for error growth which contributes to understanding the famo...

  2. EMF CHANGES MADE BY COLD DRAWING AND HEATING TREATMENT IN TYPE K HEAVY-GAUGE SHEATHED THERMOCOUPLE CABLES

    Institute of Scientific and Technical Information of China (English)

    赵容斌; 李冠军

    2002-01-01

    The electromotive force (EMF) changes in type K heavy-gauge sheathed thermocouple cables was investigated. To cope with this discrepancy owing to EMF steep reduction and understand the difference between type K heavy-gauge sheathed thermocouple cables and small ones, the affects of EMF from sheath pipe, drawing times, annealing temperature, annealing time and annealing way were mainly studied and appropriately analyzed. The results show the change in the thermal EMF is related with the residual stress and crystal defects, which are imparted by cold work during manufacture. The affects of cold work can be removed by annealing. Finally, a feasible way of fabricating heavy-gauge sheathed thermocouples was suggested according to practical situation.

  3. Seebeck Changes Due to Residual Cold-Work and Reversible Effects in Type K Bare-Wire Thermocouples

    Science.gov (United States)

    Webster, E. S.

    2017-09-01

    Type K thermocouples are the most commonly used thermocouple for industrial measurements because of their low cost, wide temperature range, and durability. As with all base-metal thermocouples, Type K is made to match a mathematical temperature-to-emf relationship and not a prescribed alloy formulation. Because different manufacturers use varying alloy formulations and manufacturing techniques, different Type K thermocouples exhibit a range of drift and hysteresis characteristics, largely due to ordering effects in the positive (K+) thermoelement. In this study, these effects are assessed in detail for temperatures below 700°C in the Type K wires from nine manufacturers. A linear gradient furnace and a high-resolution homogeneity scanner combined with the judicious use of annealing processes allow measurements that separately identify the effects of cold-work, ordering, and oxidation to be made. The results show most K+ alloys develop significant errors, but the magnitudes of the contributions of each process vary substantially between the different K+ wires. In practical applications, the measurement uncertainties achievable with Type K therefore depend not only on the wire formulation but also on the temperature, period of exposure, and, most importantly, the thermal treatments prior to use.

  4. 热电偶冷端补偿改进研究%Improvement of Cold-conjunction Compensation of Thermocouple

    Institute of Scientific and Technical Information of China (English)

    张海涛; 罗珊; 郭涛

    2011-01-01

    On the basis of discussing cold-conjunction compensation of thermocouple measurement circuit,an improving solution was provided which was based on the A/D converter ADS1224 with internal high accuracy temperature sensor. The absolute cold-conjunction temperature was measured separately. At last the temperature of heating-conjunction of thermocouple was calculated through software. The circuit, suiting to any types of thermocouple, is more optimized and the temperature is measured more accurately. The solution has the advantage such as simple hardware, low cost, high accuracy and stability.%在对现有热电偶测温冷端补偿电路进行分析的基础上,提出基于内置高精度温度传感器的模数转换芯片ADS1224的解决方案.为了提高精度和简化电路,将冷端测温电路与热电偶回路分离,冷端温度和热电偶电动势被独立进行测量,然后利用软件计算获得精确的热电偶工作端温度.同时文章也讨论了提高冷端温度测量精度的设计.实际应用说明该方案使得电路结构得到进一步优化,具有结构简单、成本低、精度高、稳定性高和抗干扰能力强等优点,具有推广价值.

  5. Intellectual compensating and testing of the thermocouple's cold spot temperature%热电偶冷端温度智能补偿与检测

    Institute of Scientific and Technical Information of China (English)

    张永枫

    2001-01-01

    介绍了具有热电偶冷端温度智能补偿的温度检测系统的组成和功能,重点阐述了以单片机为核心构成热电偶冷端温度智能补偿的原理和特点,说明了软件功能。最后给出了实践结果及主要性能指标。%The form and function of temperature testing system with intellectual compensating of the thermocouple's cold spot temperature is introduces.It emphasis tells about the principle and characteristic with single chip processor at the core which form the intellectual compensating of thermocouple's cold spot temperature.It pointed the software function.At the end,the testing results and main property targets are given.

  6. Instrumentation System Diagnoses a Thermocouple

    Science.gov (United States)

    Perotti, Jose; Santiago, Josephine; Mata, Carlos; Vokrot, Peter; Zavala, Carlos; Burns, Bradley

    2008-01-01

    An improved self-validating thermocouple (SVT) instrumentation system not only acquires readings from a thermocouple but is also capable of detecting deterioration and a variety of discrete faults in the thermocouple and its lead wires. Prime examples of detectable discrete faults and deterioration include open- and short-circuit conditions and debonding of the thermocouple junction from the object, the temperature of which one seeks to measure. Debonding is the most common cause of errors in thermocouple measurements, but most prior SVT instrumentation systems have not been capable of detecting debonding. The improved SVT instrumentation system includes power circuitry, a cold-junction compensator, signal-conditioning circuitry, pulse-width-modulation (PWM) thermocouple-excitation circuitry, an analog-to-digital converter (ADC), a digital data processor, and a universal serial bus (USB) interface. The system can operate in any of the following three modes: temperature measurement, thermocouple validation, and bonding/debonding detection. The software running in the processor includes components that implement statistical algorithms to evaluate the state of the thermocouple and the instrumentation system. When the power is first turned on, the user can elect to start a diagnosis/ monitoring sequence, in which the PWM is used to estimate the characteristic times corresponding to the correct configuration. The user also has the option of using previous diagnostic values, which are stored in an electrically erasable, programmable read-only memory so that they are available every time the power is turned on.

  7. Analysis of the ATLAS Cold Leg Top-Slot Break Experiment Using the MARS Code

    Energy Technology Data Exchange (ETDEWEB)

    Ha, T. W.; Jeong, J. J. [Pusan National University, Busan (Korea, Republic of)

    2016-10-15

    During a small-break loss of coolant accident (SBLOCA) or intermediate-break loss of coolant accident (IBLOCA) in a PWR, such as the APR1400, the steam volume in the reactor vessel upper plenum may continue to expand until the liquid phase in the horizontal intermediate legs is released, called loop seal clearing (LSC), due to the increase of the pressure in the upper plenum. A domestic standard problem (DSP) exercise using the ATLAS facility was promoted in order to transfer the database to domestic nuclear industries. For 4th DSP (DSP-04), the ATLAS cold leg top-slot break experiment was postulated. For the DSP-04, main concerns are to predict the LSC and LSR having a significantly effect on the behavior of the system under long term cooling. In this study, we simulated the ATLAS cold leg top-slot break experiment using the MARS code and the predicted LSC and LSR are compared to experimental results. The LTC-CL-04R was simulated using the MARS code. Most of the predicted results agree well with the experimental data. However, the timing of LSC and LSR is slightly different from each other and, thus, the behavior of the primary system is slightly different. The core heat up was not observed in the experiment and the calculation.

  8. An analytical investigation of cold leg small break accidents of the ATLAS facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon-Sik, E-mail: yskim3@kaeri.re.kr; Cho, Seok; Choi, Ki-Yong

    2015-09-15

    A previous parametric study of the direct vessel injection (DVI) line breaks was re-evaluated to see its applicability to that of the cold leg (CL) pipe breaks in advanced thermal-hydraulic test loop for accident simulation (ATLAS). Evaluation results of the tests and analyses for the major parameters, e.g., the pressurizer (PZR) pressure, downcomer water level, collapsed core water level, and clad temperature, were compared for four different CL pipe break scenarios. The overall trends of the major parameters showed reasonable behaviors between the tests and analyses. The clad temperature showed conservative behaviors in the analyses using the suggested options. The suggested counter-current flow limit (CCFL) options for the fuel alignment plate (FAP) and cross-over legs (COLs) can be applicable to any small-break loss-of-coolant accident (SBLOCA) scenario for the CL pipe and DVI line breaks in the ATLAS tests.

  9. Cold-Leg Small Break LOCA Analysis of APR1400 Plant Using a SPACE/sEM Code

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Gyu; Lee, Suk Ho; Yu, Keuk Jong; Kim, Han Gon; Lee, Jae Yong [Central Research Institute, KHNP, Ltd., Daejeon (Korea, Republic of)

    2013-10-15

    The Small Break Loss-of-Coolant Accident (SBLOCA) evaluation methodology (EM) for APR1400, called sEM, is now being developed using SPACE code. SPACE/sEM is to set up a conservative evaluation methodology in accordance with appendix K of 10 CFR 50. Major required and acceptable features of the evaluation models are described as below. - Fission product decay : 1.2 times of ANS97 decay curve - Critical flow model : Henry-Fauske Moody two phase critical flow model - Metal-Water reaction model : Baker-Just equation - Critical Heat Flux (CHF) : B and W, Barnett and Modified Barnett correlation - Post-CHF : Groeneveld 5.7 film boiling correlation A series of test matrix is established to validate SPACE/sEM code in terms of major SBLOCA phenomena, e.g. core level swelling and boiling, core heat transfer, critical flow, loop seal clearance and their integrated effects. The separated effect tests (SETs) and integrated effect tests (IETs) are successfully performed and these results shows that SPACE/sEM code has a conservatism comparing with experimental data. Finally, plant calculations of SBLOCA for APR1400 are conducted as described below. - Break location sensitivity : DVI line, hot-leg, cold-leg, pump suction leg. - Break size spectrum : 0.4ft{sup 2}∼0.02ft{sup 2}(DVI) 0.5ft{sup 2}∼0.02ft{sup 2}(hot-leg, cold-leg, pump suction leg) This paper deals with break size spectrum analysis of cold-leg break accidents. Based on the calculation results, emergency core cooling system (ECCS) performances of APR1400 and typical SBLOCA phenomena can be evaluated. Cold-leg SBLOCA analysis for APR1400 is performed using SPACE/sEM code under harsh environment condition. SPACE/sEM code shows the typical SBLOCA behaviors and it is reasonably predicted. Although SPACE/sEM code has conservative models and correlations based on appendix K of 10 CFR 50, PCT does not exceed the requirement (1477 K). It is concluded that ECCS in APR1400 has a sufficient performance in cold-leg SBLOCA.

  10. Self-Validating Thermocouple

    Science.gov (United States)

    Perotti, Jose M. (Inventor); Mata, Carlos T. (Inventor); Santiago, Josephine B. (Inventor); Vokrot, Peter (Inventor); Zavala, Carlos E. (Inventor); Burns, Bradley M. (Inventor)

    2010-01-01

    Self-Validating Thermocouple (SVT) Systems capable of detecting sensor probe open circuits, short circuits, and unnoticeable faults such as a probe debonding and probe degradation are useful in the measurement of temperatures. SVT Systems provide such capabilities by incorporating a heating or excitation element into the measuring junction of the thermocouple. By heating the measuring junction and observing the decay time for the detected DC voltage signal, it is possible to indicate whether the thermocouple is bonded or debonded. A change in the thermal transfer function of the thermocouple system causes a change in the rise and decay times of the thermocouple output. Incorporation of the excitation element does not interfere with normal thermocouple operation, thus further allowing traditional validation procedures as well.

  11. Thin film ceramic thermocouples

    Science.gov (United States)

    Gregory, Otto (Inventor); Fralick, Gustave (Inventor); Wrbanek, John (Inventor); You, Tao (Inventor)

    2011-01-01

    A thin film ceramic thermocouple (10) having two ceramic thermocouple (12, 14) that are in contact with each other in at least on point to form a junction, and wherein each element was prepared in a different oxygen/nitrogen/argon plasma. Since each element is prepared under different plasma conditions, they have different electrical conductivity and different charge carrier concentration. The thin film thermocouple (10) can be transparent. A versatile ceramic sensor system having an RTD heat flux sensor can be combined with a thermocouple and a strain sensor to yield a multifunctional ceramic sensor array. The transparent ceramic temperature sensor that could ultimately be used for calibration of optical sensors.

  12. Thermocouple design for measuring temperatures of small insects.

    Science.gov (United States)

    Hanson, A A; Venette, R C

    2013-01-01

    Contact thermocouples often are used to measure surface body temperature changes of insects during cold exposure. However, small temperature changes of minute insects can be difficult to detect, particularly during the measurement of supercooling points. We developed two thermocouple designs, which use 0.51 mm diameter or 0.127 mm diameter copper-constantan wires, to improve our ability to resolve insect exotherms. We tested the designs with adults from three parasitoid species: Tetrastichus planipennisi, Spathius agrili, and S. floridanus. These species are thermocouples than thick-gauge thermocouples for the smallest species tested, T. planipennisi. This difference was not apparent for larger species S. agrili and S. floridanus. Thermocouple design did not affect the mean supercooling point for any of the species. The cradle thermocouple design developed with the fine gauge wire was reusable and allowed for easy insect recovery after cold exposure.

  13. Leg pain

    Science.gov (United States)

    ... when you walk or exercise and improves with rest. The leg is black and blue. The leg is cold ... chap 81. Marcussen B, Hogrefe C, Amendola A. Leg pain and exertional compartment syndromes. In: Miller MD, Thompson SR, eds. DeLee & Drez's ...

  14. ITS-90 Thermocouple Database

    Science.gov (United States)

    SRD 60 NIST ITS-90 Thermocouple Database (Web, free access)   Web version of Standard Reference Database 60 and NIST Monograph 175. The database gives temperature -- electromotive force (emf) reference functions and tables for the letter-designated thermocouple types B, E, J, K, N, R, S and T. These reference functions have been adopted as standards by the American Society for Testing and Materials (ASTM) and the International Electrotechnical Commission (IEC).

  15. Clinical use of cold atmospheric pressure argon plasma in chronic leg ulcers: A pilot study.

    Science.gov (United States)

    Ulrich, C; Kluschke, F; Patzelt, A; Vandersee, S; Czaika, V A; Richter, H; Bob, A; Hutten, J von; Painsi, C; Hüge, R; Kramer, A; Assadian, O; Lademann, J; Lange-Asschenfeldt, B

    2015-05-01

    In the age of multiresistant microbes and the increasing lack of efficient antibiotics, conventional antiseptics play a critical role in the prevention and therapy of wound infections. Recent studies have demonstrated the antiseptic effects of cold atmospheric pressure plasma (APP). In this pilot, study we investigate the overall suitability of one of the first APP sources for wound treatment focusing on its potential antimicrobial effects. The wound closure rate and the bacterial colonisation of the wounds were investigated. Patients suffering from chronic leg ulcers were treated in a clinical controlled monocentric trial with either APP or octenidine (OCT). In patients who presented with more than one ulceration in different locations, one was treated with APP and the other one with OCT. Each group was treated three times a week over a period of two weeks. The antimicrobial efficacy was evaluated immediately after and following two weeks of treatment. Wounds treated with OCT showed a significantly higher microbial reduction (64%) compared to wounds treated with APP (47%) immediately after the treatment. Over two weeks of antiseptic treatment the bacterial density was reduced within the OCT group (-35%) compared to a slight increase in bacterial density in the APP-treated group (+12%). Clinically, there were no signs of delayed wound healing observed in either group and both treatments were well tolerated. The immediate antimicrobial effects of the APP prototype source were almost comparable to OCT without any signs of cytotoxicity. This pilot study is limited by current configurations of the plasma source, where the narrow plasma beam made it difficult to cover larger wound surface areas and in order to avoid untreated areas of the wound bed, smaller wounds were assigned to the APP-treatment group. This limits the significance of AAP-related effects on the wound healing dynamics, as smaller wounds tend to heal faster than larger wounds. However, clinical wound

  16. The Linearized Design Of Thermocouple Sensor

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>There are large errors of linear measurement when the thermocouple measure temperature as temperature sensor.In order to improve the measurement precision,the sensor cold junction compensation and nonlinear compensation are usually needed.For the circumstances that the cold junction’s temperature is determinate,there is biggish nonlinear between thermoelectric power and temperature signals of the thermocouple sensor’s output.In order to solve the problem,this paper proposed a practical method of linear compensation,introduced the principle of linear compensation and gave the corresponding compensation circuit and circuit analysis.This circuit has the characteristic of simpleness,high reliability,small linear error and so on.

  17. Core thermal hydraulic behavior during the reflood phase of cold-leg LBLOCA experiments using the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Park, Hyun Sik; Choi, Ki Yong; Kang, Kyoung Ho; Baek, Won Pil; Kim, Yeon Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-12-15

    Several experimental tests to simulate a reflood phase of a cold-leg LBLOCA of the APR1400 have been performed using the ATLAS facility. This paper describes the related experimental results with respect to the thermal-hydraulic behavior in the core and the system-core interactions during the reflood phase of the cold-leg LBLOCA conditions. The present descriptions will be focused on the LB-CL-09, LB-CL-11, LB-CL-14, and LB-CL-15 tests performed using the ATLAS. The LB-CL-09 is an integral effect test with conservative boundary condition; the LB-CL-11 and -14 are integral effect tests with realistic boundary conditions, and the LB-CL-15 is a separated effect test. The objectives of these tests are to investigate the thermal-hydraulic behavior during an entire reflood phase and to provide reliable experimental data for validating the LBLOCA analysis methodology for the APR1400. The initial and boundary conditions were obtained by applying scaling ratios to the MARS simulation results for the LBLOCA scenario of the APR1400. The ECC water flow rate from the safety injection tanks and the decay heat were simulated from the start of the reflood phase. The simulated core power was controlled to be 1.2 times that of the ANS-73 decay heat curve for LB-CL-09 and 1.02 times that of the ANS-79 decay curve for LB-CL-11, -14, and -15. The simulated ECC water flow rate from the high pressure safety injection pump was 0.32 kg/s. The present experimental data showed that the cladding temperature behavior is closely related to the collapsed water level in the core and the downcomer

  18. Cobra Probes Containing Replaceable Thermocouples

    Science.gov (United States)

    Jones, John; Redding, Adam

    2007-01-01

    A modification of the basic design of cobra probes provides for relatively easy replacement of broken thermocouples. Cobra probes are standard tube-type pressure probes that may also contain thermocouples and that are routinely used in wind tunnels and aeronautical hardware. They are so named because in side views, they resemble a cobra poised to attack. Heretofore, there has been no easy way to replace a broken thermocouple in a cobra probe: instead, it has been necessary to break the probe apart and then rebuild it, typically at a cost between $2,000 and $4,000 (2004 prices). The modified design makes it possible to replace the thermocouple, in minimal time and at relatively low cost, by inserting new thermocouple wire in a tube.

  19. High-temperature thermocouples and related methods

    Science.gov (United States)

    Rempe, Joy L.; Knudson, Darrell L.; Condie, Keith G.; Wilkins, S. Curt

    2011-01-18

    A high-temperature thermocouple and methods for fabricating a thermocouple capable of long-term operation in high-temperature, hostile environments without significant signal degradation or shortened thermocouple lifetime due to heat induced brittleness.

  20. Assessment of RELAP/MOD3 using BETHSY 6.2TC 6-inch cold leg side break comparative test

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Young-Jong; Jeong, Jae-Jun; Chang, Won-Pyo; Kim, Dong-Su [Korea Atomic Energy Research Institute, Yusung, Taejon (Korea, Republic of)] [and others

    1996-10-01

    This report presents the results of the RELAP5/MOD3 Version 7j assessment on BETHSY 6.2TC. BETHSY 6.2TC test corresponding to a six inch cold leg break LOCA of the Pressurizer Water Reactor(PWR). The primary objective of the test was to provide reference data of two facilities of different scales (BETHSY and LSTF facility). On the other hand, the present calculation aims at analysis of RELAP5/N4OD3 capability on the small break LOCA simulation, The results of calculation have shown that the RELAP5/MOD3 reasonably predicts occurrences as well as trends of the major phenomena such as primary pressure, timing of loop seal clearing, liquid hold up, etc. However, some disagreements also have been found in the predictions of loop seal clearing, collapsed core water level after loop seal clearing, and accumulator injection behaviors. For better understanding of discrepancies in same predictions, several sensitivity calculations have been performed as well. These include the changes of two-phase discharge coefficient at the break junction and some corrections of the interphase drag term. As result, change of a single parameter has not improved the overall predictions and it has been found that the interphase drag model has still large uncertainties.

  1. Simulation of a Shielded Thermocouple

    African Journals Online (AJOL)

    temperature in chemically, or mechanically, hostile environments. The sensitive ... the thermocouple is obtained by derivation of the heat propagation equation in cylindrical ..... equation (1.4) can be written as a system of of ordinary differential.

  2. Comparison of Four Cold Junction Compensation Methods Used for Measurement of S Type Thermocouple with Short Length%检定S型短型热电偶的4种不同冷端补偿方法之比较

    Institute of Scientific and Technical Information of China (English)

    吴霏; 金韵漪

    2011-01-01

    When we test the testing - length during 200 ~ 700 mm S type thermocouple, the TR is based on the room temperature or fluctuant temperature. It should take to revise or to compensate to keep the TR in 0℃. We use the widely used four cold junction compensation methods to test the same S type thermocouple, and analyze results. The results proved that the method about "the reference end is to extend the like polarity thermocouple which can reach the first standard thermocouple class of accuracy to reference end thermostat" is the better compensation method.%检定长度在200 ~ 700 mm范围内的S型热电偶时,由于参考端温度大都处于室温或者波动的温场之中,需要将参考端温度恒定在0℃或采取修正、补偿等措施进行修正.现采取检定中最常用的4种不同的冷端补偿方法检定同一支S型短型热电偶,对结果进行比较分析,得到这4种不同的冷端补偿方法的优劣性及其准确度排序.结果表明,“将参考端应用达到一等标准热电偶准确度水平的同极性热电偶丝延伸至参考端恒温器”方法能获得较为理想的补偿效果.

  3. Heat penetration and thermocouple location in home canning.

    Science.gov (United States)

    Etzel, Mark R; Willmore, Paola; Ingham, Barbara H

    2015-01-01

    We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for f h (heating), f cl (cooling), and F 82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on thermocouple location in accordance with heat transfer theory. There was a cold spot in the jar, but the cold spot during heating became the hot spot during cooling. During heating, the geometric center was the last to heat, and remained coldest the longest, but during coooling, it was also the last to cool, and remained hottest the longest. The net effect was that calculated lethality in home canning was not affected by thermocouple location. Most of the lethality during home canning occurred during air cooling, making cooling of home canned foods of great importance. Calculated lethality was far greater than the required 5-log reduction of spores in tomato juice and vegetative cells in cranberries, suggesting a wide margin of safety for approved home-canning processes for high-acid foods.

  4. Comparison of CATHARE results with the experimental results of cold leg intermediate break LOCA obtained during ROSA-2/LSTF test 7

    Directory of Open Access Journals (Sweden)

    Mazgaj Piotr

    2016-01-01

    Full Text Available Thermal-hydraulic analysis is a key part in support of regulatory work and nuclear power plant design and operation. In the field of Loss Of Coolant Accident, evolutions of the regulations are discussed in various countries taking into account the very unlikely character of a double-ended guillotine break and questioning the necessity to study such an event with Design Basis Conditions assumptions. As a consequence, the consideration of intermediate size piping rupture becomes more and more important. The paper presents the modeling of the Test Facility ROSA-2/LSTF in the calculation code CATHARE 2.V2.5. OECD/NEA ROSA-2 Project Test 7 was conducted with the Large Scale Test Facility on June 14, 2012. The experiment simulated the thermal-hydraulic responses during a PWR 13% cold leg Intermediate Break Loss Of Coolant Accident (IBLOCA. The break was simulated by a cold leg upwardly mounted long break nozzle. The facility and the experiment conditions are modeled in CATHARE. The vessel is modeled by using a 3D module. A thermal-hydraulic analysis is conducted and the obtained results are subsequently compared with the experimental results from ROSA-2/LSTF Test 7. Evaluation of the differences between experimental and calculated results is discussed.

  5. Measurement of Inhomogeneities in MIMS Thermocouples Using a Linear-Gradient Furnace and Dual Heat-Pipe Scanner

    Science.gov (United States)

    Webster, E. S.; White, D. R.; Edgar, H.

    2015-03-01

    This paper describes a linear-gradient furnace and a thermocouple homogeneity scanner that, together, measure changes in the Seebeck coefficient as a function of time and temperature. The furnace first exposes the test thermocouple to all temperatures in the range spanned by the furnace gradient. The homogeneity scanner then measures the Seebeck coefficient along the length of the thermocouple. By correlating the position on the thermocouple with the temperature in the furnace, changes in the Seebeck coefficient can be correlated with the temperature to which that part of the thermocouple was exposed. Repeat exposures for different durations allow the rapid accumulation of data describing drift versus temperature and time. The known profile of the furnace combined with the high resolution of the dual heat-pipe scanner enable the detection of Seebeck coefficient changes of less than 0.02 % over sub-millimeter distances. The high resolution of the scanner also minimizes the underestimation of short-range changes in the Seebeck coefficient. With the addition of other treatment processes, such as annealing, quenching, and cold work, the system can assess the full variety of reversible and irreversible effects in thermocouples. Preliminary experiments on base-metal thermocouples confirm much of the known long-term behavior. However, the system has also exposed the rapid onset of some of these effects at low temperatures, the large amount and variability of cold work in new thermocouples, and large variations between different thermocouples of the same type.

  6. Thermal Preconditioning of MIMS Type K Thermocouples to Reduce Drift

    Science.gov (United States)

    Webster, E. S.

    2017-01-01

    Type K thermocouples are the most widely used temperature sensors in industry and are often used in the convenient mineral-insulated metal-sheathed (MIMS) format. The MIMS format provides almost total immunity to oxide-related drift in the 800°C-1000°C range. However, crystalline ordering of the atomic structure causes drift in the range 200°C-600°C. Troublesomely, the effects of this ordering are reversible, leading to hysteresis in some applications. Typically, MIMS cable is subjected to a post-manufacturing high-temperature recrystallization anneal to remove cold-work and place the thermocouple in a `known state.' However, variations in the temperatures and times of these exposures can lead to variations in the `as-received state.' This study gives guidelines on the best thermal preconditioning of 3 mm MIMS Type K thermocouples in order to minimize drift and achieve the most reproducible temperature measurements. Experimental results demonstrate the consequences of using Type K MIMS thermocouples in different states, including the as-received state, after a high-temperature recrystallization anneal and after preconditioning anneals at 200°C, 300°, 400°C and and 500°C. It is also shown that meaningful calibration is possible with the use of regular preconditioning anneals.

  7. Method for bonding thin film thermocouples to ceramics

    Science.gov (United States)

    Kreider, Kenneth G.

    1993-01-01

    A method is provided for adhering a thin film metal thermocouple to a ceramic substrate used in an environment up to 700 degrees Centigrade, such as at a cylinder of an internal combustion engine. The method includes the steps of: depositing a thin layer of a reactive metal on a clean ceramic substrate; and depositing thin layers of platinum and a platinum-10% rhodium alloy forming the respective legs of the thermocouple on the reactive metal layer. The reactive metal layer serves as a bond coat between the thin noble metal thermocouple layers and the ceramic substrate. The thin layers of noble metal are in the range of 1-4 micrometers thick. Preferably, the ceramic substrate is selected from the group consisting of alumina and partially stabilized zirconia. Preferably, the thin layer of reactive metal is in the range of 0.015-0.030 micrometers (15-30 nanometers) thick. The preferred reactive metal is chromium. Other reactive metals may be titanium or zirconium. The thin layer of reactive metal may be deposited by sputtering in ultra high purity argon in a vacuum of approximately 2 milliTorr (0.3 Pascals).

  8. Thermocouple Structure in Thermoelectric Conversion Devices

    Institute of Scientific and Technical Information of China (English)

    WU; Wei-ming; TANG; Xian; LUO; Zhi-fu

    2013-01-01

    The core of thermoelectric conversion device is the thermocouples which are constituted with P-type and N-type thermoelectric material.Thermocouple structure is very important for efficiency of thermoelectric power generation.Common thermocouple is the segmented structure,as shown in Fig.1.Each material works in its best temperature range.This structure ensures that the device get a high figure

  9. Attaching Thermocouples by Peening or Crimping

    Science.gov (United States)

    Murtland, Kevin; Cox, Robert; Immer, Christopher

    2006-01-01

    Two simple, effective techniques for attaching thermocouples to metal substrates have been devised for high-temperature applications in which attachment by such conventional means as welding, screws, epoxy, or tape would not be effective. The techniques have been used successfully to attach 0.005- in. (0.127-mm)-diameter type-S thermocouples to substrates of niobium alloy C-103 and stainless steel 416 for measuring temperatures up to 2,600 F (1,427 C). The techniques are equally applicable to other thermocouple and substrate materials. In the first technique, illustrated in the upper part of the figure, a hole slightly wider than twice the diameter of one thermocouple wire is drilled in the substrate. The thermocouple is placed in the hole, then the edge of the hole is peened in one or more places by use of a punch (see figure). The deformed material at the edge secures the thermocouple in the hole. In the second technique a hole is drilled as in the first technique, then an annular relief area is machined around the hole, resulting in structure reminiscent of a volcano in a crater. The thermocouple is placed in the hole as in the first technique, then the "volcano" material is either peened by use of a punch or crimped by use of sidecutters to secure the thermocouple in place. This second technique is preferable for very thin thermocouples [wire diameter .0.005 in. (.0.127 mm)] because standard peening poses a greater risk of clipping one or both of the thermocouple wires. These techniques offer the following advantages over prior thermocouple-attachment techniques: . Because these techniques involve drilling of very small holes, they are minimally invasive . an important advantage in that, to a first approximation, the thermal properties of surrounding areas are not appreciably affected. . These techniques do not involve introduction of any material, other than the substrate and thermocouple materials, that could cause contamination, could decompose, or oxidize

  10. Evaluation of Thermocouple Temperature Sensors in a Simulated Mars Environment

    Science.gov (United States)

    Sykulska-Lawrence, Hanna; Mansell, J.; Bowles, N.; Calcutt, S.; Temple, J.

    2010-10-01

    The Martian environment is meteorologically extremely dry, dusty, cold (with a large diurnal temperature change), is irradiated by UV and is probably highly chemically oxidising. Detailed measurements of the near-surface atmospheric temperature profile coupled with other meteorological data allow the dynamics of the Martian atmospheric boundary layer to be investigated. This is of particular importance given the atmosphere's tendency to turbulent mixing observed by previous experiments, on e.g. Mars Pathfinder within a few metres of the surface. We examine thermocouple sensors for the Mars environment by evaluating the sensor designed for the AEP instrument, a meteorology package previously selected for the ExoMars geophysics lander. The design of the sensor contains three thin wire thermocouples for redundancy in a configuration based on those flown on the Viking, Mar Pathfinder and Phoenix landers. Thin-wire thermocouples offer the best type of temperature sensor for in-situ atmospheric temperature measurements as they have a fast response time, are less sensitive to radiative heat coupling and do not have problems with self-heating. The sensor described in this presentation is accurate to < 0.25K. The work presented will describe the sensor itself and provide results of detailed calibration tests in an isothermal Mars environmental chamber (simulating the temperatures, pressure and atmospheric composition expected near the surface) testing the instruments accuracy, and response in relation to the thermal capacity of the wire. Further to this, numerical models used to investigate the difficulties in correctly measuring the temperature of the atmosphere will be described. These models consider effects such as radiative heating from direct sunlight or radiation reflected from the surface, shielding from flowing air. Having studied the behaviour of this sensor and different types of design of thermocouple weld, including re-examining the Viking sensors, if

  11. AGR-1 Thermocouple Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Einerson

    2012-05-01

    This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of

  12. Side-welded fast response sheathed thermocouple

    Science.gov (United States)

    Carr, K.R.

    A method of fabricating the measuring junction of a grounded-junction sheathed thermocouple to obtain fast time response and good thermal cycling performance is provided. Slots are tooled or machined into the sheath wall at the measuring junction, the thermocouple wires are laser-welded into the slots. A thin metal closure cap is then laser-welded over the end of the sheath. Compared to a conventional grounded-junction thermocouple, the response time is 4 to 5 times faster and the thermal shock and cycling capabilities are substantially improved.

  13. Field guide to quick deployment thermocouples

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Instructions for quick deployment of thermocouples to measure fire intensity at Kulm Wetland Management District as part of the Fire Intensity Monitoring survey....

  14. Connecting to Thermocouples with Fewer Lead Wires

    Science.gov (United States)

    Goldsby, Jon C.

    2003-01-01

    A simple technique has been devised to reduce the number of lead wires needed to connect an array of thermocouples to the instruments (e.g., voltmeters) used to read their output voltages. Because thermocouple wires are usually made of expensive metal alloys, reducing the number of lead wires can effect a considerable reduction in the cost of such an array. Reducing the number of wires also reduces the number of terminals and the amount of space needed to accommodate the wires.

  15. Improvement of COBRA-TF for modeling of PWR cold- and hot-legs during reactor transients

    Science.gov (United States)

    Salko, Robert K.

    capture of more advanced physics in the coolant-line that can be expected during Loss-of-Coolant Accident. One of the package's benefits is its ability to be used as a platform for future coolant-line model development and implementation, including capturing of the important de-entrainment behavior in reactor hot-legs (steam-binding effect) and flow convection in the upper-plenum region of the vessel.

  16. Segmented metal nanowires as nanoscale thermocouples.

    Science.gov (United States)

    Shapira, E; Marchak, D; Tsukernik, A; Selzer, Y

    2008-03-26

    Segmented Au-Ni nanowires are demonstrated to be highly effective thermocouples with a spatial resolution of a few nanometers and a temporal resolution in the microsecond range. The performance of the devices is characterized by a self-heating procedure in which an ac heating current with frequency ω is applied on the wires while monitoring the resulting thermoelectric voltage V(TH) at 2ω using a lock-in technique. An analytical model is developed that enables one to determine the time response of the thermocouples from plots of V(TH) as a function of ω.

  17. Process Simulating of Heat Transfer in High-temperature Thermocouples

    Directory of Open Access Journals (Sweden)

    Atroshenko Yuliana K.

    2015-01-01

    Full Text Available Numerical research of integral characteristics of process of heattransfer in sensitive elements of R, A and B types thermocouples in case of measurement of high temperatures (more than 900 K is executed. Theoretical dependences of minimum necessary duration of heating up of the thermocouple on value of temperature on boundary of a sensitive element are received. It is shown the thermocouple of R type requires bigger time of heating for obtaining satisfactory accuracy of measurements. Temperature fields in sensitive elements of the specified thermocouples are received. It is shown that distribution of temperature on the thermocouple not linearly and has similar character for the researched thermocouples.

  18. Welding Wires To Thin Thermocouple Films

    Science.gov (United States)

    Holanda, Raymond; Kim, Walter S.; Danzey, Gerald A.; Pencil, Eric; Wadel, Mary

    1993-01-01

    Parallel-gap resistance welding yields joints surviving temperatures of about 1,000 degrees C. Much faster than thermocompression bonding. Also exceeds conductive-paste bonding and sputtering thin films through porous flame-sprayed insulation on prewelded lead wires. Introduces no foreign material into thermocouple circuit and does not require careful control of thickness of flame-sprayed material.

  19. Performance Evaluation of an Infrared Thermocouple

    Directory of Open Access Journals (Sweden)

    Te-Ching Shen

    2010-11-01

    Full Text Available The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from −1.8 °C to 18 °C as the reading values served as the true values. Within the range from 13 °C to 37 °C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20 °C to 35 °C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4 °C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures.

  20. Thermometry of the surface of human skin. A study on a model using thermocouples, thermistors, thermovision and thermodyes.

    Science.gov (United States)

    Flesch, U; Wegener, O H; Scheffler, A; Ernst, H

    1976-05-01

    The temperature of the surface of a model of human skin is measured using a recently developed probe to house a thermocouple or thermistor. The results are compared with thermovision and thermodye measurements. The effect on skin temperature of hot and cold vessels at various depths is investigated.

  1. Computer program for pulsed thermocouples with corrections for radiation effects

    Science.gov (United States)

    Will, H. A.

    1981-01-01

    A pulsed thermocouple was used for measuring gas temperatures above the melting point of common thermocouples. This was done by allowing the thermocouple to heat until it approaches its melting point and then turning on the protective cooling gas. This method required a computer to extrapolate the thermocouple data to the higher gas temperatures. A method that includes the effect of radiation in the extrapolation is described. Computations of gas temperature are provided, along with the estimate of the final thermocouple wire temperature. Results from tests on high temperature combustor research rigs are presented.

  2. Ceramic thin film thermocouples for SiC-based ceramic matrix composites

    Energy Technology Data Exchange (ETDEWEB)

    Wrbanek, John D., E-mail: John.D.Wrbanek@nasa.gov; Fralick, Gustave C.; Zhu Dongming

    2012-06-30

    Conductive ceramic thin film thermocouples were investigated for application to silicon carbide fiber reinforced silicon carbide ceramic matrix composite (SiC/SiC CMC) components. High temperature conductive oxides based on indium and zinc oxides were selected for testing to high temperatures in air. Sample oxide films were first sputtered-deposited on alumina substrates then on SiC/SiC CMC sample disks. Operational issues such as cold junction compensation to a 0 Degree-Sign C reference, resistivity and thermopower variations are discussed. Results show that zinc oxides have an extremely high resistance and thus increased complexity for use as a thermocouple, but thermocouples using indium oxides can achieve a strong, nearly linear response to high temperatures. - Highlights: Black-Right-Pointing-Pointer Oxide thin film thermocouples tested for SiC/SiC ceramic matrix composites (CMCs) Black-Right-Pointing-Pointer In{sub 2}O{sub 3}, N:In{sub 2}O{sub 3}, ZnO, AlZnO sputtered and tested on Al{sub 2}O{sub 3} and CMC substrates Black-Right-Pointing-Pointer ZnO, AlZnO have high resistance, complex temperature response. Black-Right-Pointing-Pointer In{sub 2}O{sub 3}, N:In{sub 2}O{sub 3} conductive at room temperature, more linear temperature response.

  3. Use of manganin-constantan thermocouples in thermometry units designed for copper-constantan thermocouples.

    Science.gov (United States)

    Hoh, L L; Waterman, F M

    1995-01-01

    Commercial ultrasound hyperthermia systems typically include thermometry units designed for copper-constantan thermocouples. Replacing these copper-constantan thermocouples with manganin-constantan thermocouples is advantageous in reducing the measurement error caused by the conduction of heat along the copper wire, but their performance in these thermometry units is uncertain. The accuracy of manganin-constantan thermocouples in the Labthermics LT-100, Clini-Therm TS1200/TM100, and Physitemp TM-12 thermometry units was investigated using a temperature controlled circulating water bath monitored by a mercury thermometer having a calibration traceable to NIST. The results demonstrate that an accuracy of +/- 0.2 degrees C can be achieved with manganin-constantan thermocouples over the range 35-55 degrees C without hardware modification provided specific calibration procedures are followed. With the Labthermics LT-100, a double point calibration should be carried out at 35 and 55 degrees C. With the Clini-Therm TS1200/TM100, a self-calibration of the unit using its internal calibration well plus a single point calibration using an external temperature standard provides sufficient accuracy. The Physitemp TM-12 requires an external computer for read out and the user must provide additional software to correct for the error by either a single or multiple point calibration.

  4. Nanoscale thermometry using point contact thermocouples.

    Science.gov (United States)

    Sadat, Seid; Tan, Aaron; Chua, Yi Jie; Reddy, Pramod

    2010-07-14

    Probing temperature fields with nanometer resolution is critical to understanding nanoscale thermal transport as well as dissipation in nanoscale devices. Here, we demonstrate an atomic force microscope (AFM)-based technique capable of mapping temperature fields in metallic films with approximately 10 mK temperature resolution and thermocouples on a grid. The local temperature at each point contact is obtained by measuring the thermoelectric voltage of the platinum-gold point contact and relating it to the local temperature. These results demonstrate a direct measurement of the temperature field of a metallic surface without using specially fabricated scanning temperature-probes.

  5. ROSA/LSTF experiment report for RUN SB-CL-24 repeated core heatup phenomena during 0.5% cold leg break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Mitsuhiro; Anoda, Yoshinari [Department of Reactor Safety Research, Nuclear Safety Research Center, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-03-01

    A small break loss-of-coolant accident (SBLOCA) in a Westinghouse-type four-loop PWR was simulated in an experiment (SB-CL-24) conducted at the Large-Scale Test Facility (LSTF) with an intention to study repeated core heatup during a long-term cooldown process. The experiment was conducted on February 28, 1990 with specified test conditions including failure assumptions both on the high pressure injection (HPI) and the auxiliary feedwater systems, and the intentional secondary system depressurization as an operator action. The secondary depressurization contributed to promote the primary depressurization and the actuation of accumulator injection system (AIS). A temporary core heatup was observed in each of three loopseal clearing (LSC) processes. A significant core heatup occurred in the following boil-off process after loss of the secondary coolant mass and the AIS termination due to increase of the primary pressure. By additional opening of the pressurizer relief valves and safety valves, the primary pressure rapidly decreased to result in the low pressure injection (LPI) which cooled the heated core. This report summarizes results of the experiment (SB-CL-24) in addition to typical responses of some accident indication systems including the core exit thermocouples (CETs) and the water level meters in the primary system. (author)

  6. Symmetry Analysis of Thermoelectric Energy Converters with Inhomogeneous Legs

    Science.gov (United States)

    Korzhuev, M. A.

    2010-09-01

    Symmetry analysis has been applied to thermoelectric energy converters [thermoelectric generators (TEG), coolers (TEC), and heaters (TEH)] with inhomogeneous legs. The features of the crystallographic symmetry of thermoelectric materials and the symmetry of legs, thermocouples, and modules are studied. The effect of symmetry on the figure of merit Z of thermoelectric energy converters is considered. A general rule for proper placement of legs in thermoelectric converters is developed. A modified tetratomic classification for thermoelectric energy converters with inhomogeneous legs (TEGa, TEGb, TEC, and TEH) is proposed. An increase in Z for thermoelectric energy converters with inhomogeneous legs is due to the bulk thermoelectric effect. An increase in Z gives the reduction of irreversible processes in the modules (Joule heating and thermal conductivity), accompanying breaking of the symmetry of the legs. It is found that violations of the symmetry requirements can lead to significant energy losses in converters.

  7. Process Simulating of Heat Transfer in High-temperature Thermocouples

    OpenAIRE

    Atroshenko Yuliana K.; Bychkova Alena A.

    2015-01-01

    Numerical research of integral characteristics of process of heattransfer in sensitive elements of R, A and B types thermocouples in case of measurement of high temperatures (more than 900 K) is executed. Theoretical dependences of minimum necessary duration of heating up of the thermocouple on value of temperature on boundary of a sensitive element are received. It is shown the thermocouple of R type requires bigger time of heating for obtaining satisfactory accuracy of measurements. Tempera...

  8. Thermocouple time constant measurement by cross power spectra

    Science.gov (United States)

    Strahle, W. C.; Muthukrishnan, M.

    1976-01-01

    A method of measuring thermocouple time constants is outlined which requires Fourier signal processing. In this method, two thermocouples of differing time constants are placed in a gas flow as closely as possible to one another, and the time constant of the first thermocouple is determined directly from the extremum of the imaginary part of the ratio of the ensemble averaged cross-power spectrum to the ensemble averaged auto-power spectrum of that thermocouple. A coherence function is given for assuring the quality of the data, and results are presented for an experimental test of the method. Some problems with the method are briefly noted.

  9. Aminopeptidase activity by spoilage bacteria and its relationship to microbial load and sensory attributes of poultry legs during aerobic cold storage.

    Science.gov (United States)

    Guevara-Franco, José Alfredo; Alonso-Calleja, Carlos; Capita, Rosa

    2010-02-01

    The shelf life of poultry legs stored aerobically and the possible role of the aminopeptidase activity of gram-negative bacteria (p-nitroaniline test) as a predictor of poultry spoilage were evaluated on the basis of microbiological and sensory parameters. Chicken legs (n = 30) obtained immediately after evisceration in a local poultry processing plant were kept under aerobic refrigeration (4 +/- 1 degrees C) for 7 days. Microbiological (counts of aerobic bacteria and psychrotrophs) and sensory (odor, color, and general acceptability on a hedonic scale of 1 to 9) parameters and aminopeptidase activity (absorbance at 390 nm [A(390)]) determinations were performed after 0, 1, 3, 5, and 7 days of storage. Aerobic plate counts of 7 log CFU/g and a score of 6 for general acceptability were used as indicators of the end point of shelf life. Strong correlations (r > or = 0.76; P counts, hedonic scores, and A(390) values. Samples were judged as unacceptable (shelf-life end point) after 2 and 4 days on the basis of sensory and microbiological analyses, respectively. A(390) values of 0.52 and 0.89 (corresponding to p-nitroaniline concentrations of 6.25 and 10.7 microg/ml, respectively) are proposed as the upper limits for acceptability on the basis of sensory and microbiological determinations, respectively. However, these recommendations are based on a small set of samples, and their general application is yet to be verified.

  10. Thermocouple Extension-Wire-Connections and Low Temperatures

    Science.gov (United States)

    Figueroa, Fernando; Mitchell, Mark; Richardson, Gregory

    2000-01-01

    Experiments were carried out to determine the casue of erroneous readings from thermocouples of type K when measuring temperatures of liquid hydrogen. It was believed to be linked to te temperature of the connector used to extend the thermocouple wires to the voltage meter.

  11. Heat production in microwave-irradiated thermocouples.

    Science.gov (United States)

    Dunscombe, P B; McLellan, J; Malaker, K

    1986-01-01

    It has been known for some time that the irradiation of metallic thermometers by microwaves during clinical hyperthermia can lead to artifactual readings. We describe here a series of measurements in which this effect has been quantitatively studied. In particular, the data yield values for the conversion coefficient describing the rate of heat production per unit length of a thermocouple array per watt applied power which can be compared with the rate of heat production in the same volume of tissue. The degree of artifact in the temperature recording depends on the thermal resistance of the protective materials surrounding the array, and this thermal resistance has also been determined. It has been shown that measures taken to reduce the temperature artifact do not compromise the response time of the probe.

  12. Electrodeposited submicron thermocouples with microsecond response times.

    Science.gov (United States)

    Bourg, M E; van der Veer, W E; Güell, A G; Grüell, A G; Penner, R M

    2007-10-01

    We describe a procedure for preparing submicron scale silver-nickel thermocouples (TCs) using electrochemical step edge decoration on graphite surfaces. Each fabrication operation produced ensembles of 2-20 TCs with diameters in the 1.0 microm to 500 nm range. These "sub-mum TCs" (SMTCs) produced linear voltage versus temperature output over the range from 20 to 100 degrees C characterized by a Seebeck coefficient of 20 +/- 1 microV/degrees C, equal to the 21 microV/degrees C that is theoretically expected for a junction between these two metals. The time response of SMTCs was evaluated using two different laser-heating methods and compared with the smallest mechanically robust commercially available type J TCs. Electrochemical etching of the silver wire introduced constrictions at grain boundaries that reduced the thermal mass of the junction without altering its integrity or its overall diameter, producing a decrease of the measured rise time for SMTCs up to 96%.

  13. Metallic and ceramic thin film thermocouples for gas turbine engines.

    Science.gov (United States)

    Tougas, Ian M; Amani, Matin; Gregory, Otto J

    2013-11-08

    Temperatures of hot section components in today's gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges) for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stability at high temperatures in oxidizing atmospheres, they are compatible with thermal barrier coatings commonly employed in today's engines, they have greater sensitivity than conventional wire thermocouples, and they are non-invasive to combustion aerodynamics in the engine. Thin film thermocouples based on platinum:palladium and indium oxynitride:indium tin oxynitride as well as their oxide counterparts have been developed for this purpose and have proven to be more stable than conventional type-S and type-K thin film thermocouples. The metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and drift rates similar to bulk (wire) thermocouples.

  14. Miniature sheathed thermocouples for turbine blade temperature measurement

    Science.gov (United States)

    Holanda, R.; Glawe, G. E.; Krause, L. N.

    1974-01-01

    An investigation was made of sheathed thermocouples for turbine blade temperature measurements. Tests were performed on the Chromel-Alumel sheathed thermocouples with both two-wire and single-wire configurations. Sheath diameters ranged from 0.25 to 0.76 mm, and temperatures ranged from 1080 to 1250 K. Both steady-state and thermal cycling tests were performed for times up to 450 hr. Special-order and commercial-grade thermocouples were tested. The tests showed that special-order single-wire sheathed thermocouples can be obtained that are reliable and accurate with diameters as small as 0.25 mm. However, all samples of 0.25-mm-diameter sheathed commercial-grade two-wire and single-wire thermocouples that were tested showed unacceptable drift rates for long-duration engine testing programs. The drift rates were about 1 percent in 10 hr. A thermocouple drift test is recommended in addition to the normal acceptance tests in order to select reliable miniature sheathed thermocouples for turbine blade applications.

  15. Metallic and Ceramic Thin Film Thermocouples for Gas Turbine Engines

    Directory of Open Access Journals (Sweden)

    Otto J. Gregory

    2013-11-01

    Full Text Available Temperatures of hot section components in today’s gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stability at high temperatures in oxidizing atmospheres, they are compatible with thermal barrier coatings commonly employed in today’s engines, they have greater sensitivity than conventional wire thermocouples, and they are non-invasive to combustion aerodynamics in the engine. Thin film thermocouples based on platinum:palladium and indium oxynitride:indium tin oxynitride as well as their oxide counterparts have been developed for this purpose and have proven to be more stable than conventional type-S and type-K thin film thermocouples. The metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and drift rates similar to bulk (wire thermocouples.

  16. Development of Thin Film Ceramic Thermocouples for High Temperature Environments

    Science.gov (United States)

    Wrbanek, John D.; Fralick, Gustave C.; Farmer, Serene C.; Sayir, Ali; Blaha, Charles A.; Gonzalez, Jose M.

    2004-01-01

    The maximum use temperature of noble metal thin film thermocouples of 1100 C (2000 F) may not be adequate for use on components in the increasingly harsh conditions of advanced aircraft and next generation launch technology. Ceramic-based thermocouples are known for their high stability and robustness at temperatures exceeding 1500 C, but are typically found in the form of rods or probes. NASA Glenn Research Center is investigating the feasibility of ceramics as thin film thermocouples for extremely high temperature applications to take advantage of the stability and robustness of ceramics and the non-intrusiveness of thin films. This paper will discuss the current state of development in this effort.

  17. Use of miniature, single-wire, sheathed thermocouples

    Science.gov (United States)

    Glawe, G. E.; Holanda, R.; Krause, L. N.

    1977-01-01

    Temperature measurement with small thermocouples is improved by device. Each wire is sheathed separately which increases the interelement insulation by factor of 2 1/2. Each wire in its separate sheath can be brought to junction by independent paths.

  18. Processing Techniques for Correlation of LDA and Thermocouple Signals,

    Science.gov (United States)

    particular when few seeding particles are present in the flow. The thermocouple signal was analog compensated in frequency and the effect of the value of time constant on the velocity temperature correlation was studied.

  19. Thin-Film Ceramic Thermocouples Fabricated and Tested

    Science.gov (United States)

    Wrbanek, John D.; Fralick, Gustave C.; Farmer, Serene C.; Sayir, Ali; Gregory, Otto J.; Blaha, Charles A.

    2004-01-01

    The Sensors and Electronics Technology Branch of the NASA Glenn Research Center is developing thin-film-based sensors for surface measurement in propulsion system research. Thin-film sensors do not require special machining of the components on which they are mounted, and they are considerably thinner than wire- or foil-based sensors. One type of sensor being advanced is the thin-film thermocouple, specifically for applications in high-temperature combustion environments. Ceramics are being demonstrated as having the potential to meet the demands of thin-film thermocouples in advanced aerospace environments. The maximum-use temperature of noble metal thin-film thermocouples, 1500 C (2700 F), may not be adequate for components used in the increasingly harsh conditions of advanced aircraft and next-generation launch vehicles. Ceramic-based thermocouples are known for their high stability and robustness at temperatures exceeding 1500 C, but are typically in the form of bulky rods or probes. As part of ASTP, Glenn's Sensors and Electronics Technology Branch is leading an in-house effort to apply ceramics as thin-film thermocouples for extremely high-temperature applications as part of ASTP. Since the purity of the ceramics is crucial for the stability of the thermocouples, Glenn's Ceramics Branch and Case Western Reserve University are developing high-purity ceramic sputtering targets for fabricating high-temperature sensors. Glenn's Microsystems Fabrication Laboratory, supported by the Akima Corporation, is using these targets to fabricate thermocouple samples for testing. The first of the materials used were chromium silicide (CrSi) and tantalum carbide (TaC). These refractory materials are expected to survive temperatures in excess of 1500 C. Preliminary results indicate that the thermoelectric voltage output of a thin-film CrSi versus TaC thermocouple is 15 times that of the standard type R (platinum-rhodium versus platinum) thermocouple, producing 20 mV with a 200

  20. Metallic and Ceramic Thin Film Thermocouples for Gas Turbine Engines

    OpenAIRE

    Gregory, Otto J.; Matin Amani; Ian M. Tougas

    2013-01-01

    Temperatures of hot section components in today’s gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges) for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stabil...

  1. Sea Legs

    Science.gov (United States)

    Macdonald, Kenneth C.

    Forty-foot, storm-swept seas, Spitzbergen polar bears roaming vast expanses of Arctic ice, furtive exchanges of forbidden manuscripts in Cold War Moscow, the New York city fashion scene, diving in mini-subs to the sea floor hot srings, life with the astronauts, romance and heartbreak, and invading the last bastions of male exclusivity: all are present in this fast-moving, non-fiction account of one woman' fascinating adventures in the world of marine geology and oceanography.

  2. Low-Temperature Drift in MIMS Base-Metal Thermocouples

    Science.gov (United States)

    Webster, E. S.

    2014-04-01

    Inhomogeneities are known to develop within thermoelements exposed to elevated temperatures, resulting in temperature measurement errors. While the Seebeck coefficient drift in base-metal thermocouples due to aging at temperatures over has been extensively investigated, there have been very few investigations into possible Seebeck changes at lower temperatures. Despite warnings about possible effects, most practitioners assume changes in homogeneity are either not significant or not able to develop at temperatures less than . This study reports on measurements of inhomogeneities in base-metal thermocouples arising from heat treatment at temperatures in the region of . Thermoelectric scans of thermocouples were carried out following exposure of a range of mineral-insulated metal-sheathed base-metal thermocouples, from two large manufacturers, of Types E, J, K, N, and T, to either a linear-gradient furnace within the range of to or uniform temperature zones of , , and . The experiments reveal noticeable drift in all base-metal types for temperatures as low as and exposure times as short as 1 h. The most sensitive thermoelement alloys appear to be Constantan, Alumel, and Nicrosil. It is concluded that the common working assumption that base-metal thermocouples suffer no thermally induced changes in the Seebeck coefficient below is false. This observation has significant implications for many high-stability monitoring and control systems reliant on base-metal thermocouples that operate in the range of to . Additionally, thermoelectric scanning of base-metal thermocouples should be carried out at temperatures well below to avoid erasure of strain effects or imprinting of new thermal signatures.

  3. The reliability of thermocouples in microwave ceramics processing.

    Science.gov (United States)

    Aguilar, Juan; Valdez, Zarel; Ortiz, Ubaldo

    2004-01-01

    It is not rare to hear arguments against the use of thermocouples for taking temperatures in processes that are taking place under microwave fields. However, the simplicity of this device makes it attractive to consider its use. One question that arises when thermocouples are employed is whether the electric field perturbs the measurement, and if the thermocouple affects the processing. The process that was chosen for conducting this test was the synthesis of spinel (MgAl2O4) using microwaves as a power supply and hematite (Fe2O3) as an additive for both spinel formation promotion and susceptor. The alumina-based systems are very important to study because this is one of the most common ingredients in refractory materials. There are many discussions about the improvement of the process when microwaves are used, but a kinetic comparison cannot be performed if the temperature is unknown, and that is the reason for emphasizing the measurement techniques. The analysis of the obtained samples was carried out by X-ray diffraction of powders. The results of this work show that there is no difference between the products obtained when the thermocouple was inserted in the system, compared to processing without it; hence the thermocouple is appropriate for this application.

  4. Measurements of fluctuating gas temperatures using compensated fine wire thermocouples

    Science.gov (United States)

    Nina, M. N. R.; Pita, G. P.

    1985-09-01

    Thermocouples with three different wire diameters (15, 40 and 50 microns) were used in association with an analog compensation circuit connected to a data acquisition system. Measurements of the time constant were performed using two different heating techniques; Joule effect and external heating by laser beam. The thermocouples were used to quantify the fluctuating temperature field in a hot air jet and in a premixed propane flame. In the reacting case the catalytic effect was evaluated by comparing coated and uncoated wires. Conclusions were also obtained regarding frequency spectra, temperature probability distribution function and time constant.

  5. A Comparison of Contemporary Gold Versus Platinum Thermocouples with NIST SRM 1749-Based Thermocouples and Reference Function

    Science.gov (United States)

    Coleman, M. J.; Wiandt, T. J.; Harper, T.

    2015-12-01

    Fluke Calibration (formerly Hart Scientific) in American Fork, Utah, USA is a manufacturer of temperature calibration instruments. The company manufactured reference standard gold versus platinum (Au-Pt) thermocouples from 1992 to about 2002. Manufacturing was halted in 2002 because a trend of poor curve-fit results was observed in new batches of wire. After reviewing the possible sources of the problem, it was decided to sample wire from multiple manufacturers and investigate ways to make the curve-fit work better. This paper presents the results from the study of the wire and a characterization technique to help improve characterization of thermocouples made with lower purity wire. Calibration results from NIST SRM material and older Fluke thermocouples are included as well to provide a means of comparison of contemporary wire to NIST SRM era wire.

  6. Thermocouples--The Most Widely Used Temperature Sensor in Manufacturing

    Science.gov (United States)

    Mitts, Charles R.

    2006-01-01

    Researchers predict that future developments in nanotechnology will bring incredible, almost inconceivable, change to the manufacturing industry. For now, though, one of technology's most trusted tools remains very relevant: In the field of thermometry, thermocouples are a tried and true technology. As a consequence, material on thermocouples…

  7. Numerical Research of the Measurement Error of Temperature Thermocouples with the Isolated Seal

    OpenAIRE

    Atroshenko Yuliana K.; Bychkova Alena A.; Strizhak Pavel A.

    2015-01-01

    Mathematical models of heattransfer are developed for an assessment of measurement errors of temperature by thermocouples with an isolated and uninsulated seal. Dependences of necessary time of heating (for authentic measurement) for the thermocouples with an isolated seal manufactured of different materials are set. It is shown that for thermocouples with isolated seal minimum necessary duration of heating up slightly exceeds this index for thermocouples with an uninsulated seal.

  8. Restless Legs Syndrome Foundation

    Science.gov (United States)

    ... Into Relieved Are you experiencing symptoms linked to restless legs syndrome (RLS)? Find tools and support to help get ... I couldn’t sleep. Fortunately, I found the Restless Legs Syndrome Foundation and learned what type of doctor to ...

  9. Restless Legs Syndrome

    Science.gov (United States)

    ... and Teens, Men, WomenTags: neurological disorders, restless legs syndrome, RLS, sitting, sleep disorders, sleeping, uncomfortable feeling in legs at rest Family Health, Kids and Teens, Men, Women November ...

  10. The practical use of thermocouples for temperature measurement in clinical hyperthermia.

    Science.gov (United States)

    Carnochan, P; Dickinson, R J; Joiner, M C

    1986-01-01

    The use of thermocouples as invasive thermometers in clinical hyperthermia is comprehensively and critically reviewed. The ability to construct thermocouple probes as small-bore, multiple junction assemblies is a major reason for their popularity and full constructional details are given. The potential sources of measurement error when using thermocouples both in temperature gradients and in electromagnetic or ultrasonic heating fields are discussed. Emphasis is placed upon simple practical solutions to these problems and a combination of good measurement practice and electrical filtering can reduce errors to an insignificant level. Techniques are suggested for the assessment of thermocouple performance during clinical measurement. With careful use, thermocouples can be reliable and convenient thermometers.

  11. Tungsten-rhenium thin film thermocouples for SiC-based ceramic matrix composites

    Science.gov (United States)

    Tian, Bian; Zhang, Zhongkai; Shi, Peng; Zheng, Chen; Yu, Qiuyue; Jing, Weixuan; Jiang, Zhuangde

    2017-01-01

    A tungsten-rhenium thin film thermocouple is designed and fabricated, depending on the principle of thermal-electric effect caused by the high temperature. The characteristics of thin film thermocouples in different temperatures are investigated via numerical analysis and analog simulation. The working mechanism and thermo-electric features of the thermocouples are analyzed depending on the simulation results. Then the thin film thermocouples are fabricated and calibrated. The calibration results show that the thin film thermocouples based on the tungsten-rhenium material achieve ideal static characteristics and work well in the practical applications.

  12. Material Problems in Using High-Temperature Thermocouples

    Science.gov (United States)

    Edler, F.

    2011-08-01

    The material compatibility and thermal stability of ceramic-composite coatings of different oxide ceramics deposited on alumina tubes to prevent the reduction of the alumina were investigated in the high-temperature range between 1750 °C and 1850 °C. It turned out that the coatings were thermally unstable and did not provide adequate protection against the reduction of the alumina tubes. The oxide ceramics formed eutectic compositions with low melting temperatures and were also prone to reduction to elementary metals by carbon. A new type of high-temperature thermocouple on the basis of refractory and noble metals was tested in the temperature range between 1325 °C and 1800 °C. Two metal-sheathed prototypes were constructed. The thermoelectric behavior of the tungsten5%rhenium/iridium thermocouples (W5%Re/Ir) was investigated by different high-temperature exposures, and the thermoelectric stability was checked by repeated measurements at the ice point.

  13. Hysteresis Effects and Strain-Induced Homogeneity Effects in Base Metal Thermocouples

    Science.gov (United States)

    Pavlasek, P.; Elliott, C. J.; Pearce, J. V.; Duris, S.; Palencar, R.; Koval, M.; Machin, G.

    2015-03-01

    Thermocouples are used in a wide variety of industrial applications in which they play an important role for temperature control and monitoring. Wire inhomogeneity and hysteresis effects are major sources of uncertainty in thermocouple measurements. To efficiently mitigate these effects, it is first necessary to explore the impact of strain-induced inhomogeneities and hysteresis, and their contribution to the uncertainty. This article investigates homogeneity and hysteresis effects in Types N and K mineral-insulated metal-sheathed (MIMS) thermocouples. Homogeneity of thermocouple wires is known to change when mechanical strain is experienced by the thermoelements. To test this influence, bends of increasingly small radii, typical in industrial applications, were made to a number of thermocouples with different sheath diameters. The change in homogeneity was determined through controlled immersion of the thermocouple into an isothermal liquid oil bath at and was found to be very small at for Type K thermocouples, with no measureable change in Type N thermocouples found. An experiment to determine the hysteresis effect in thermocouples was performed on swaged, MIMS Type N and Type K thermocouples, in the temperature range from to . The hysteresis measurements presented simulate the conditions that thermocouples may be exposed to in industrial applications through continuous cycling over 136 h. During this exposure, a characteristic drift from the reference function has been observed but no considerable difference between the heating and cooling measurements was measureable. The measured differences were within the measurement uncertainties; therefore, no hysteresis was observed.

  14. Evaluation of piecewise polynomial equations for two types of thermocouples.

    Science.gov (United States)

    Chen, Andrew; Chen, Chiachung

    2013-12-12

    Thermocouples are the most frequently used sensors for temperature measurement because of their wide applicability, long-term stability and high reliability. However, one of the major utilization problems is the linearization of the transfer relation between temperature and output voltage of thermocouples. The linear calibration equation and its modules could be improved by using regression analysis to help solve this problem. In this study, two types of thermocouple and five temperature ranges were selected to evaluate the fitting agreement of different-order polynomial equations. Two quantitative criteria, the average of the absolute error values |e|(ave) and the standard deviation of calibration equation e(std), were used to evaluate the accuracy and precision of these calibrations equations. The optimal order of polynomial equations differed with the temperature range. The accuracy and precision of the calibration equation could be improved significantly with an adequate higher degree polynomial equation. The technique could be applied with hardware modules to serve as an intelligent sensor for temperature measurement.

  15. Evaluation of Piecewise Polynomial Equations for Two Types of Thermocouples

    Directory of Open Access Journals (Sweden)

    Andrew Chen

    2013-12-01

    Full Text Available Thermocouples are the most frequently used sensors for temperature measurement because of their wide applicability, long-term stability and high reliability. However, one of the major utilization problems is the linearization of the transfer relation between temperature and output voltage of thermocouples. The linear calibration equation and its modules could be improved by using regression analysis to help solve this problem. In this study, two types of thermocouple and five temperature ranges were selected to evaluate the fitting agreement of different-order polynomial equations. Two quantitative criteria, the average of the absolute error values |e|ave and the standard deviation of calibration equation estd, were used to evaluate the accuracy and precision of these calibrations equations. The optimal order of polynomial equations differed with the temperature range. The accuracy and precision of the calibration equation could be improved significantly with an adequate higher degree polynomial equation. The technique could be applied with hardware modules to serve as an intelligent sensor for temperature measurement.

  16. Evaluation of a postulated loss of coolant accident (LOCA) due to a 160 cm{sup 2} break in a cold leg of Angra 2 nuclear power plant[LOCA; RELAP-5/MOD3.2.2g; nodalization]; Calculo do acidente postulado de perda de refrigerante por uma ruptura de 160 cm{sup 2} na perna fria da central nuclear Angra 2

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, Carlos Vicente Goulart de; Palmieri, Elcio Tadeu; Aronne, Ivan Dionysio [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    2002-07-01

    The development of a qualified full nodalization of Angra2 NPP for RELAP5/Mod 3.2.2 gamma, aiming at the evaluation of a comprehensive number of accidents and transients, thus providing suitable safety analysis support for licensing purposes, is being carried out within the framework of CNEN internal technical cooperation, involving some of its institutes (CDTN, IPEN and IEN) and the Reactors Coordination (CODRE). This work presents a simulation of a postulated Angra2 small cold leg break loss of coolant accident (SBLOCA). A 160 cm{sup 2} break is supposed to occur at one cold leg between the main coolant pump and the reactor vessel and is described in the Angra2 Final Safety Analysis Report, section 15.6.4.1.3.4. The simulation of several types of transients and accidents is necessary to verify the adequate performance of the modeled logic and systems. In general, the analysis of such and accident allows to demonstrate the safety Injection System performance and the reliable transition between the high pressure safety injection, the accumulator injection and the residual heat removal phases. Furthermore, it is assumed that some components are out of service due to fail or repair in order to make a conservative analysis. The results showed a compatible behavior of the molded systems and that the simulated Emergency Core Cooling System was able to provide sufficient cooling to avoid any damage to the core. (author)

  17. Enhancements to High Temperature In-Pile Thermocouple Performance

    Energy Technology Data Exchange (ETDEWEB)

    J. C. Crepeau; J. L. Rempe; J. E. Daw; D. L. Knudson; K. G. Condie; S. C. Wilkins

    2008-03-01

    A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped lybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 °C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them

  18. Enhancements to High Temperature In-Pile Thermocouple Performance

    Energy Technology Data Exchange (ETDEWEB)

    J.C. Crepeau; J.L. Rempe; J.E. Daw; D.L. Knudson: K.G. Condie; S.C. Wilkins

    2008-03-31

    A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them

  19. Characterization of a Method for Inverse Heat Conduction Using Real and Simulated Thermocouple Data

    Science.gov (United States)

    Pizzo, Michelle E.; Glass, David E.

    2017-01-01

    It is often impractical to instrument the external surface of high-speed vehicles due to the aerothermodynamic heating. Temperatures can instead be measured internal to the structure using embedded thermocouples, and direct and inverse methods can then be used to estimate temperature and heat flux on the external surface. Two thermocouples embedded at different depths are required to solve direct and inverse problems, and filtering schemes are used to reduce noise in the measured data. Accuracy in the estimated surface temperature and heat flux is dependent on several factors. Factors include the thermocouple location through the thickness of a material, the sensitivity of the surface solution to the error in the specified location of the embedded thermocouples, and the sensitivity to the error in thermocouple data. The effect of these factors on solution accuracy is studied using the methodology discussed in the work of Pizzo, et. al.1 A numerical study is performed to determine if there is an optimal depth at which to embed one thermocouple through the thickness of a material assuming that a second thermocouple is installed on the back face. Solution accuracy will be discussed for a range of embedded thermocouple depths. Moreover, the sensitivity of the surface solution to (a) the error in the specified location of the embedded thermocouple and to (b) the error in the thermocouple data are quantified using numerical simulation, and the results are discussed.

  20. Summary of thermocouple performance during advanced gas reactor fuel irradiation experiments in the advanced test reactor and out-of-pile thermocouple testing in support of such experiments

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, A. J.; Haggard, DC; Herter, J. W.; Swank, W. D.; Knudson, D. L.; Cherry, R. S. [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, (United States); Scervini, M. [University of Cambridge, Department of Material Science and Metallurgy, 27 Charles Babbage Road, CB3 0FS, Cambridge, (United Kingdom)

    2015-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple-based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time-dependent change in composition and, as a consequence, a time-dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C). For lower temperature applications, previous experiences with Type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly, Type N thermocouples are expected to be only slightly affected by neutron fluence. Currently, the use of these nickel-based thermocouples is limited when the temperature exceeds 1000 deg. C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past 10 years, three long-term Advanced Gas Reactor experiments have been conducted with measured temperatures ranging from 700 deg. C - 1200 deg. C. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out-of-pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150 deg. C and 1200 deg. C for 2,000 hours at each temperature, followed by 200 hours at 1250 deg. C and 200 hours at 1300 deg. C. The standard Type N design utilizes high purity, crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including a Haynes 214 alloy sheath, spinel (MgAl{sub 2}O{sub 4}) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly

  1. Summary of Thermocouple Performance During Advanced Gas Reactor Fuel Irradiation Experiments in the Advanced Test Reactor and Out-of-Pile Thermocouple Testing in Support of Such Experiments

    Energy Technology Data Exchange (ETDEWEB)

    A. J. Palmer; DC Haggard; J. W. Herter; M. Scervini; W. D. Swank; D. L. Knudson; R. S. Cherry

    2011-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B); and tungsten-rhenium thermocouples (Types C and W). For lower temperature applications, previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of these Nickel based thermocouples is limited when the temperature exceeds 1000°C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past ten years, three long-term Advanced Gas Reactor (AGR) experiments have been conducted with measured temperatures ranging from 700oC – 1200oC. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out of pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150oC and 1200oC for 2000 hours at each temperature, followed by 200 hours at 1250oC, and 200 hours at 1300oC. The standard Type N design utilizes high purity crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including Haynes 214 alloy sheath, spinel (MgAl2O4) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard fired alumina

  2. Heat Flux estimation in WEST divertor with embedded thermocouples

    Science.gov (United States)

    Gaspar, J.; Corre, Y.; Firdaouss, M.; Gardarein, J.-L.; Guilhem, D.; Houry, M.; Le Niliot, C.; Missirlian, M.; Pocheau, C.; Rigollet, F.

    2016-09-01

    The present paper deals with the surface heat flux estimation with embedded thermocouples (TC) in a Plasma Facing Component (PFC) of the WEST Tokamak. A 2D nonlinear unsteady calculation combined with the Conjugate Gradient Method (CGM) and the adjoint state is achieved in order to estimate the time evolution of the heat flux amplitude and decay length λq . The method is applied on different synthetic measurements in order to evaluate the accuracy of the method. The synthetic measurements are generated with realistic values of λq and magnitudes as those expected for ITER.

  3. Recent improvements on micro-thermocouple based SThM

    Science.gov (United States)

    Nguyen, TP; Thiery, L.; Teyssieux, D.; Briand, D.; Vairac, P.

    2017-01-01

    The scanning thermal microscope (SThM) has become a versatile tool for local surface temperature mapping or measuring thermal properties of solid materials. In this article, we present recent improvements in a SThM system, based on a micro-wire thermocouple probe associated with a quartz tuning fork for contact strength detection. Some results obtained on an electrothermal micro-hotplate device, operated in active and passive modes, allow demonstrating its performance as a coupled force detection and thermal measurement system.

  4. Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures

    Science.gov (United States)

    Ungar, Eugene K.; Wright, Sarah E.

    2016-01-01

    Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the original test and the analysis that showed that the thermocouples had become detached, temporary thermocouple attachment methods assessed in the retest and in the thermocouple attachment test, and makes a recommendation for attachment methods for future tests.

  5. Lyden-af-Leg

    DEFF Research Database (Denmark)

    Toft, Herdis

    Præsentation af seniorforsker-projekt Lyden-af-Leg i et traderingsperspektiv og med indledende fokus på YouTube som traderings-platform.......Præsentation af seniorforsker-projekt Lyden-af-Leg i et traderingsperspektiv og med indledende fokus på YouTube som traderings-platform....

  6. Heat flux measurements on ceramics with thin film thermocouples

    Science.gov (United States)

    Holanda, Raymond; Anderson, Robert C.; Liebert, Curt H.

    1993-01-01

    Two methods were devised to measure heat flux through a thick ceramic using thin film thermocouples. The thermocouples were deposited on the front and back face of a flat ceramic substrate. The heat flux was applied to the front surface of the ceramic using an arc lamp Heat Flux Calibration Facility. Silicon nitride and mullite ceramics were used; two thicknesses of each material was tested, with ceramic temperatures to 1500 C. Heat flux ranged from 0.05-2.5 MW/m2(sup 2). One method for heat flux determination used an approximation technique to calculate instantaneous values of heat flux vs time; the other method used an extrapolation technique to determine the steady state heat flux from a record of transient data. Neither method measures heat flux in real time but the techniques may easily be adapted for quasi-real time measurement. In cases where a significant portion of the transient heat flux data is available, the calculated transient heat flux is seen to approach the extrapolated steady state heat flux value as expected.

  7. Cold Stress

    Science.gov (United States)

    ... Publications and Products Programs Contact NIOSH NIOSH COLD STRESS Recommend on Facebook Tweet Share Compartir Workers who ... cold environments may be at risk of cold stress. Extreme cold weather is a dangerous situation that ...

  8. Development of a Sheathed Miniature Aerothermal Reentry Thermocouple for Thermal Protection System Materials

    Science.gov (United States)

    Martinez, Edward R.; Weber, Carissa Tudryn; Oishi, Tomo; Santos, Jose; Mach, Joseph

    2011-01-01

    The Sheathed Miniature Aerothermal Reentry Thermocouple is a micro-miniature thermocouple for high temperature measurement in extreme environments. It is available for use in Thermal Protection System materials for ground testing and flight. This paper discusses the heritage, and design of the instrument. Experimental and analytical methods used to verify its performance and limitations are described.

  9. Localization of focused-ultrasound beams in a tissue phantom, using remote thermocouple arrays.

    Science.gov (United States)

    Hariharan, Prasanna; Dibaji, Seyed Ahmad Reza; Banerjee, Rupak K; Nagaraja, Srinidhi; Myers, Matthew R

    2014-12-01

    In focused-ultrasound procedures such as vessel cauterization or clot lysis, targeting accuracy is critical. To investigate the targeting accuracy of the focused-ultrasound systems, tissue phantoms embedded with thermocouples can be employed. This paper describes a method that utilizes an array of thermocouples to localize the focused ultrasound beam. All of the thermocouples are located away from the beam, so that thermocouple artifacts and sensor interference are minimized. Beam propagation and temperature rise in the phantom are simulated numerically, and an optimization routine calculates the beam location that produces the best agreement between the numerical temperature values and those measured with thermocouples. The accuracy of the method was examined as a function of the array characteristics, including the number of thermocouples in the array and their orientation. For exposures with a 3.3-MHz source, the remote-thermocouple technique was able to predict the focal position to within 0.06 mm. Once the focal location is determined using the localization method, temperatures at desired locations (including the focus) can be estimated from remote thermocouple measurements by curve fitting an analytical solution to the heat equation. Temperature increases in the focal plane were predicted to within 5% agreement with measured values using this method.

  10. New Technology for Remote Testing of Response Time of Installed Thermocouples. Volume 2 - Research Data

    Science.gov (United States)

    1992-01-01

    specific need for a thermocouple with known rapid response time. Glawe and Holanda ~ have reported an extensive study to determine thermocouple time...Continuous Flow Crvo.qenic Tunnel," NASA Technical Memorandum 81825, May 1980. Glawe, G. E., Holanda , R., Krause, L. N., "Recovery and Radiation Corrections

  11. Theoretical and Experimental Research of Error of Method of Thermocouple with Controlled Profile of Temperature Field

    Science.gov (United States)

    Jun, Su; Kochan, O.; Chunzhi, Wang; Kochan, R.

    2015-12-01

    The method of study and experimental researches of the error of method of the thermocouple with controlled profile of temperature field along the main thermocouple are considered in this paper. Experimentally determined values of error of method are compared to the theoretical estimations done using Newton's law of cooling. They converge well.

  12. Theoretical and Experimental Research of Error of Method of Thermocouple with Controlled Profile of Temperature Field

    OpenAIRE

    Jun Su; Kochan O.; Chunzhi Wang; Kochan R.

    2015-01-01

    The method of study and experimental researches of the error of method of the thermocouple with controlled profile of temperature field along the main thermocouple are considered in this paper. Experimentally determined values of error of method are compared to the theoretical estimations done using Newton’s law of cooling. They converge well.

  13. 77 FR 30435 - In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core

    Science.gov (United States)

    2012-05-23

    ... COMMISSION 10 CFR Part 50 In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core... ``require all holders of operating licenses for nuclear power plants (``NPP'') to operate NPPs with in-core thermocouples at different elevations and radial positions throughout the reactor core.'' DATES: Submit...

  14. High-Temperature, Thin-Film Ceramic Thermocouples Developed

    Science.gov (United States)

    Sayir, Ali; Blaha, Charles A.; Gonzalez, Jose M.

    2005-01-01

    To enable long-duration, more distant human and robotic missions for the Vision for Space Exploration, as well as safer, lighter, quieter, and more fuel efficient vehicles for aeronautics and space transportation, NASA is developing instrumentation and material technologies. The high-temperature capabilities of thin-film ceramic thermocouples are being explored at the NASA Glenn Research Center by the Sensors and Electronics Branch and the Ceramics Branch in partnership with Case Western Reserve University (CWRU). Glenn s Sensors and Electronics Branch is developing thin-film sensors for surface measurement of strain, temperature, heat flux, and surface flow in propulsion system research. Glenn s Ceramics Branch, in conjunction with CWRU, is developing structural and functional ceramic technology for aeropropulsion and space propulsion.

  15. Leg 179 summary

    Digital Repository Service at National Institute of Oceanography (India)

    Pettigrew, T.J.; Casey, J.F.; Miller, D.J.; Araki, E.; Boissonnas, R.; Busby, R.; Einaudi, F.; Gerdom, M.; Guo, Z.P.; Hopkins, H.; Myers, G.; Rao, D.G.; Shibata, T.; Thy, P.

    Ocean Drilling Program (ODP) Leg 179 set out with two primary objectives. These objectives were (1) testing the recently developed hammer drill-in casing system on the Atlantis Bank, Southwest Indian Ridge (SWIR), and (2) drilling a cased reentry...

  16. RESTLESS LEGS SYNDROME

    Directory of Open Access Journals (Sweden)

    Dmitriy Valer'evich Artem'ev

    2009-01-01

    Full Text Available The paper describes the epidemiology, etiology, pathogenesis, clinical picture, diagnosis, differential diagnosis, and treatment of restless legs syndrome. Recommendations are given how to choose therapeutic modalities and drugs in relation to different factors.

  17. Lifetime improvement of sheathed thermocouples for use in high-temperature and thermal operations

    Science.gov (United States)

    McCulloch, R. W.; Clift, J. H.

    Premature failure of small-diameter, magnesium-oxide-insulated sheathed thermocouples occurred when they were placed within nuclear fuel rod simulators to measure high temperatures and to follow severe thermal transients encountered during simulation of nuclear accidents in Oak Ridge National Laboratory thermal-hydraulic test facilities. Investigation of thermally cycled thermocouples yielded three criteria for improvement of thermocouple lifetime: (1) reduction of oxygen impurities prior to and during their fabrication; (2) refinement of thermoelement grain size during their fabrication; and (3) elimination of prestrain prior to use above their recrystallization temperature. The first and third criteria were satisfied by improved techniques of thermocouple assembly and by a recovery anneal prior to thermocouple use.

  18. Research on Hardware Performance for Thermocouple Temperature Measurement Modules%热电偶温度测量模块硬件性能研究

    Institute of Scientific and Technical Information of China (English)

    陈名宝

    2012-01-01

    Thermocouple is an important measurement tool in thermal detection measurement. Researching the antijamming ability of the Thermocouple temperature sensor module has the great significance. This paper,begin with the performance index of thermocouple temperature sensor module,and combining the theory analysis and experimental cases,design a kind of high precision,strong anti-jamming performance of hardware. Developed the products with the cold junction compensation and thread break detector function,can through a series of electromagnetic compatibility test,can satisfy most of the industrial application.%热电偶是热工检测中重要的计量工具,研究热电偶测温模块的抗干扰性能具有重大意义.该文从热电偶测温模块性能指标出发,结合理论分析和实验案例,设计出精度高,抗干扰性能强的硬件.开发出来的产品具有冷端补偿和断线检测功能,能通过一系列电磁兼容性测试,可以满足绝大部分工业场景应用要求.

  19. The transient response for different types of erodable surface thermocouples using finite element analysis

    Directory of Open Access Journals (Sweden)

    Mohammed Hussein

    2007-01-01

    Full Text Available The transient response of erodable surface thermocouples has been numerically assessed by using a two dimensional finite element analysis. Four types of base metal erodable surface thermocouples have been examined in this study, included type-K (alumel-chromel, type-E (chromel-constantan, type-T (copper-constantan, and type-J (iron-constantan with 50 mm thick- ness for each. The practical importance of these types of thermocouples is to be used in internal combustion engine studies and aerodynamics experiments. The step heat flux was applied at the surface of the thermocouple model. The heat flux from the measurements of the surface temperature can be commonly identified by assuming that the heat transfer within these devices is one-dimensional. The surface temperature histories at different positions along the thermocouple are presented. The normalized surface temperature histories at the center of the thermocouple for different types at different response time are also depicted. The thermocouple response to different heat flux variations were considered by using a square heat flux with 2 ms width, a sinusoidal surface heat flux variation width 10 ms period and repeated heat flux variation with 2 ms width. The present results demonstrate that the two dimensional transient heat conduction effects have a significant influence on the surface temperature history measurements made with these devices. It was observed that the surface temperature history and the transient response for thermocouple type-E are higher than that for other types due to the thermal properties of this thermocouple. It was concluded that the thermal properties of the surrounding material do have an impact, but the properties of the thermocouple and the insulation materials also make an important contribution to the net response.

  20. Cold Urticaria

    Science.gov (United States)

    Diseases and Conditions Cold urticaria By Mayo Clinic Staff Cold urticaria (ur-tih-KAR-e-uh) is a skin reaction to cold. Skin that has ... in contact with cold develops reddish, itchy welts (hives). The severity of cold urticaria symptoms varies widely. ...

  1. Venous leg ulcers.

    Science.gov (United States)

    Nelson, E Andrea

    2011-12-21

    Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of advice about self-help interventions in people receiving usual care for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2011 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). We found 101 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide

  2. Use of thermocouples in the intense fields of ferromagnetic implant hyperthermia.

    Science.gov (United States)

    Chan, K W; Chou, C K

    1993-01-01

    Thermocouples have been used in the intense fields of ferromagnetic implant hyperthermia for extensive temperature measurements. Electromagnetic interference at 100 kHz is minimized with feed-through filters mounted on a copper plate in a shielded assembly. The thermocouples are temperature compensated in the software by monitoring the temperature of the copper plate. D-shell connectors are used for multiple sensor thermocouple connections and to provide proper shield termination of external cables. The technical approaches of grounding, shielding and filtering are examined, and experiments have been conducted to determine the proper usage of thermocouple during ferromagnetic implant treatments. The dependence of filter performance on thermocouple impedance and the effect of D-shell connections on temperature accuracy have been studied. The results indicate that self-heating due to electromagnetic energy coupled into 51 microns thermocouple leads and unbalanced current along 76 microns leads are insignificant at 100 kHz. But severe heating has been observed in 511 and 813 microns leads, especially in high-conductivity copper wires. By using 25-50 microns thermocouple leads, better than 0.1 degree C accuracy and 0.05 degree C resolution have been achieved during ferromagnetic hyperthermia. At field strength of 1500 A/m, artifacts of 0.03-0.05 degree C are observed.

  3. Temperature artifacts produced by thermocouples used in conjunction with 1 and 3 MHz ultrasound.

    Science.gov (United States)

    Waterman, F M; Leeper, J B

    1990-01-01

    The relative temperature artifacts produced by a selection of commercially available thermocouples and catheters were evaluated in radiation bolus and beef phantoms heated by 1 and 3 MHz continuous ultrasound. The thermocouples included a 23 gauge needle microprobe inserted directly into the phantoms, polyurethane-sheathed, Teflon-sheathed, and exposed-tip thermocouples, each inserted into a 19 gauge polyurethane closed-end catheter, a multisensor Teflon-sheathed probe inserted into a 16 gauge polyurethane catheter and a Teflon-sheathed single-sensor probe without a catheter. The needle microprobe and the polyurethane-sheathed thermocouple produce equivalent artifacts. The artifacts produced by the Teflon and exposed-tip thermocouples are 1.4 +/- 0.3 times greater, that produced by the multisensor Teflon-sheathed probe is 2.1 +/- 0.3 times greater, and that produced by the Teflon-sheathed thermocouple without a catheter is 2.3 +/- 0.4 times greater. The results in the beef phantom indicate that the needle microprobe and polyurethane-sheathed thermocouple both produce artifacts of 0.7 +/- 0.1 degree in tissue at an SAR of 100 W/kg.

  4. Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory

    Science.gov (United States)

    Brewer, Ethan J.; Pawlik, Ralph J.; Krause, David L.

    2013-01-01

    Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.

  5. Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures - Test Results

    Science.gov (United States)

    Wright, Sarah E.; Ungar, Eugene K.

    2017-01-01

    Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the testing that was performed in early and mid-2017. The test article and the temporary thermocouple attachment methods tested are described. During the first test, fully half of the thermocouples detached - although the detachment showed subtly in the data for some. The second test was performed to confirm the data from the first test and to investigate the effect of test article and thermocouple grounding. The results of the testing over temperatures ranging from -150 to 200degF are detailed and preliminary recommendations are made for temporary thermocouple attachment methods.

  6. [Restless legs syndrome].

    Science.gov (United States)

    Lai, Szu-Chia; Chen, Rou-Shayn

    2008-03-01

    The restless legs syndrome (RLS) is a common neurological disorder to take possession of increasing attention. RLS is characterized by an urge to move the legs, usually accompanied by uncomfortable or unpleasant sensations, that occurs or worsen at rest and is relieved by activity. The symptoms of RLS have a major impact on nocturnal sleep and daytime functions. The clinical diagnostic criteria were established and published in 2003 by International Restless Legs Syndrome Study Group (IRLSSG). All four essential criteria must be met for a positive diagnosis. However, RLS encompassed an idiopathic form of genetic or unknown origin and secondary forms associated with many causes. Special awareness should be kept for differential diagnosis such as uremia, iron deficiency anemia, polyneuropathy, rheumatoid arthritis, and other neurodegenerative diseases. Polysomnography, actinography, L-dopa loading test, and suggested immobilization test (SIT) are helpful tools to reduce the diagnostic puzzle of false positive and false negative. Pathophysiological concepts of RLS are essentially based on the neuroimaging and neurophysiological data to assume a dysfunction of the dopaminergic system, possibly on the All neuron group localized in the hypothalamus. These neurons modulate spinal excitability and alter the sensory processing predominantly of leg afferents. Treatment may be closely linked to the dopaminergic system and iron metabolism. Dopaminergic stimulation with levodopa or dopamine agonists is the first choice in idiopathic restless legs syndrome, but the long-term adverse effect of augmentation should be carefully monitored.

  7. Thermoelectric properties of currently available Au/Pt thermocouples related to the valid reference function

    Directory of Open Access Journals (Sweden)

    Edler F.

    2015-01-01

    Full Text Available Au/Pt thermocouples are considered to be an alternative to High Temperature Standard Platinum Resistance Thermometers (HTSPRTs for realizing temperatures according to the International Temperature Scale of 1990 (ITS-90 in the temperature range between aluminium (660.323 °C and silver (961.78 °C. The original aim of this work was to develop and to validate a new reference function for Au/Pt thermocouples which reflects the properties of presently commercially available Au and Pt wires. The thermoelectric properties of 16 Au/Pt thermocouples constructed at different National Metrological Institutes by using wires from different suppliers and 4 commercially available Au/Pt thermocouples were investigated. Most of them exhibit significant deviations from the current reference function of Au/Pt thermocouples caused by the poor performance of the Au-wires available. Thermoelectric homogeneity was investigated by measuring immersion profiles during freezes at the freezing point of silver and in liquid baths. The thermoelectric inhomogeneities were found to be one order of magnitude larger than those of Au/Pt thermocouples of the Standard Reference Material® (SRM® 1749. The improvement of the annealing procedure of the gold wires is a key process to achieve thermoelectric homogeneities in the order of only about (2–3 mK, sufficient to replace the impracticable HTSPRTs as interpolation instruments of the ITS-90. Comparison measurements of some of the Au/Pt thermocouples against a HTSPRT and an absolutely calibrated radiation thermometer were performed and exhibit agreements within the expanded measurement uncertainties. It has been found that the current reference function of Au/Pt thermocouples reflects adequately the thermoelectric properties of currently available Au/Pt thermocouples.

  8. Effects of thermocouple electrical insulation on the measurement of surface temperature

    OpenAIRE

    AlWaaly, Ahmed A.Y.; Paul, Manosh C; Dobson, Phillip S.

    2015-01-01

    Analytical, numerical and experimental analyses have been performed to investigate the effects of thermocouple wire electrical insulation on the temperature measurement of a reference surface. Two diameters of type K thermocouple, 80 μm and 200 μm, with different exposed wire lengths (0 mm, 5 mm, 10 mm, 15 mm and 20 mm) were used to measure various surface temperatures (4 °C, 8 °C, 15 °C, 25 °C and 35 °C). Measurements were made with the thermocouple in direct contact with the surface, with w...

  9. Studies of Behavior Melting Temperature Characteristics for Multi Thermocouple In-Core Instrument Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Donghyup; Chae, Myoungeun; Kim, Sungjin; Lee, Kyulim [Woojin inc, Hwasung (Korea, Republic of)

    2015-05-15

    Bottom-up type in-core instruments (ICIs) are used for the pressurized water reactors of OPR-1000, APR- 1400 in order to measure neutron flux and temperature in the reactor. It is a well-known technique and a proven design using years in the nuclear field. ICI consists of one pair of K-type thermocouple, five self-powered neutron detectors (SPNDs) and one back ground detector. K-type thermocouple's purpose is to measure the core exit temperature (CET) in the reactor. The CET is a very important factor for operating nuclear power plants and it is 327 .deg. C when generally operating the reactor in the nuclear power plant(NPP) in case of OPR- 1000. If the CET will exceed 650 .deg. C, Operators in the main control room should be considered to be an accident situation in accordance with a severe accident management guidance(SAMG). The Multi Thermocouple ICI is a new designed ICI assuming severe accident conditions. It consists of four more thermocouples than the existing design, so it has five Ktype thermocouples besides the thermocouple measuring CET is located in the same elevation as the ICI. Each thermocouple is able to be located in the desired location as required. The Multi Thermocouple ICI helps to measure the temperature distribution of the entire reactor. In addition, it will measure certain point of melted core because of the in-vessel debris of nuclear fuel when an accident occurs more seriously. In this paper, to simulate a circumstance such as a nuclear reactor severe accident was examined. In this study, the K-type thermocouples of Multi Thermocouple ICI was confirmed experimentally to be able to measure up to 1370 .deg. C before the thermocouples have been melted. And after the thermocouples were melted by debris, it was able to be monitored that the signal of EMF directed the infinite value of voltage. Therefore through the results of the test, it can be assumed that if any EMF data among the Multi Thermocouple ICI will direct the infinite value

  10. Calibration of thermocouple psychrometers and moisture measurements in porous materials

    Science.gov (United States)

    Guz, Łukasz; Sobczuk, Henryk; Połednik, Bernard; Guz, Ewa

    2016-07-01

    The paper presents in situ method of peltier psychrometric sensors calibration which allow to determine water potential. Water potential can be easily recalculated into moisture content of the porous material. In order to obtain correct results of water potential, each probe should be calibrated. NaCl salt solutions with molar concentration of 0.4M, 0.7M, 1.0M and 1.4M, were used for calibration which enabled to obtain osmotic potential in range: -1791 kPa to -6487 kPa. Traditionally, the value of voltage generated on thermocouples during wet-bulb temperature depression is calculated in order to determine the calibration function for psychrometric in situ sensors. In the new method of calibration, the field under psychrometric curve along with peltier cooling current and duration was taken into consideration. During calibration, different cooling currents were applied for each salt solution, i.e. 3, 5, 8 mA respectively, as well as different cooling duration for each current (from 2 to 100 sec with 2 sec step). Afterwards, the shape of each psychrometric curve was thoroughly examined and a value of field under psychrometric curve was computed. Results of experiment indicate that there is a robust correlation between field under psychrometric curve and water potential. Calibrations formulas were designated on the basis of these features.

  11. Hemoglobinopathies and Leg Ulcers.

    Science.gov (United States)

    Alavi, Afsaneh; Kirsner, Robert S

    2015-09-01

    Major hemoglobinopathies, including sickle cell anemia, are becoming a global health issue. Leg ulcers are the most common cutaneous manifestation of sickle cell disease and an important contributor to morbidity burden in this population. Leg ulcers following sickling disorders are extremely painful, and hard to heal. The clinical evidence for the optimal management of these ulcers is limited. Treating the cause and the strategies to prevent sickling are the mainstay of treatment. The basic principles of wound bed preparation and compression therapy is beneficial in these patients.

  12. Design of Digital Thermocouple Sensors Based on Single Chip Processors%基于单片机的数字式热电偶传感器设计

    Institute of Scientific and Technical Information of China (English)

    于剑超; 董恩生; 李清亮

    2014-01-01

    A conventional thermocouple has some disadvantages: its output signal is weak, making it difficult for a long distance signal transmission;it needs temperature compensation at cold junctions, making the application inconvenient;and its output signal is an analog signal, making it complex for doing a digital measurement. As to these problems, this paper introduced a measuring circuit based on a computer, which can directly measure the output signals of thermocouples and automatically make the cold-junction temperature compensation. The measuring re-sults from the circuit are turned into RS232 serial signals to output. The thermocouple equipped with the circuit will be able to output digital sig-nals corresponding to the measured temperature. So the design is of high practical value.%针对热电偶传感器存在的输出热电势信号小、不便于远距离传输,需要进行冷端温度补偿、不便于使用,输出的是模拟信号、不便于实现数字式测量等问题,提出一种基于单片机的测量电路,该电路可对热电偶输出的信号进行测量,并能够自动进行冷端温度补偿,测量结果转换为RS232串行信号向外输出。热电偶传感器配备上该测量电路,便可实现所测温度的数字输出,具有较高的实用性。

  13. The mangled lower leg

    NARCIS (Netherlands)

    Hoogendoorn, Jochem Maarten

    2002-01-01

    A surgeon faced with a patient presenting with an open tibial/fibular fracture in combination with severe damage of the surrounding soft tissues, has to make the difficult decision whether to attempt salvage or to perform an immediate amputation of the leg. Until late in the nineteenth century the

  14. Leg med vision

    DEFF Research Database (Denmark)

    Munk, Mette; Bertelsen, Katrine

    2011-01-01

    alle med interesse for leg og bevægelse i daginstitutioner. Bogen er skrevet i et samarbejde mellem Ringsted Kommune og det nationale videncenter for sundhed, kost og motion for børn og unge, KOSMOS (www.vicekosmos.dk).Der er i samarbejde med to daginstitutioner indhentet vigtige og kvalificerede...

  15. Leg CT scan

    Science.gov (United States)

    ... x-ray beam rotates around you. (Modern "spiral" scanners can perform the exam without stopping.) A computer creates separate images of the body area, called slices. These images can be stored, viewed on a monitor, or printed on film. Three-dimensional (3D) models of the leg can be created by ...

  16. Evaluation of miniature single-wire sheathed thermocouples for turbine blade temperature measurement

    Science.gov (United States)

    Hollanda, R.

    1979-01-01

    Chromel Alumel thermocouples were used, with sheath diameters of 0.15 and 0.25 mm. Tests were conducted at temperatures ranging from 750 to 1250 K. Both steady state and thermal cycling tests were performed for times up to 200 hours. Initial testing was performed in a low velocity gas stream for long time periods using a Meker-type burner. Additional testing was done in a high velocity gas stream for short time periods using a hot gas tunnel and also in a J75 jet engine. A total of eleven 0.15 mm diameter thermocouples and six 0.25 mm diameter thermocouples were tested. Drift rates up to 2.5% in 10 hours were observed. Photomicrographs show that this design is near the limit of miniaturization based on present manufacturing capabilities. Results indicate that the effects of miniaturization on reliability and accuracy must be considered when choosing thermocouples for a particular application.

  17. Leg design in hexapedal runners

    National Research Council Canada - National Science Library

    Full, R J; Blickhan, R; Ting, L H

    1991-01-01

    .... To explain how diverse leg designs can result in common whole-body dynamics, we used a miniature force platform to measure the ground reaction forces produced by individual legs of the cockroach Blaberus discoidalis...

  18. Attachment of Free Filament Thermocouples for Temperature Measurements on CMC

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1997-01-01

    Ceramic Matrix Composites (CMC) are being developed for use as enabling materials for advanced aeropropulsion engine and high speed civil transport applications. The characterization and testing of these advanced materials in hostile, high-temperature environments require accurate measurement of the material temperatures. Commonly used wire Thermo-Couples (TC) can not be attached to this ceramic based material via conventional spot-welding techniques. Attachment of wire TC's with commercially available ceramic cements fail to provide sufficient adhesion at high temperatures. While advanced thin film TC technology provides minimally intrusive surface temperature measurement and has good adhesion on the CMC, its fabrication requires sophisticated and expensive facilities and is very time consuming. In addition, the durability of lead wire attachments to both thin film TC's and the substrate materials requires further improvement. This paper presents a newly developed attachment technique for installation of free filament wire TC's with a unique convoluted design on ceramic based materials such as CMC's. Three CMC's (SiC/SiC CMC and alumina/alumina CMC) instrumented with type IC, R or S wire TC's were tested in a Mach 0.3 burner rig. The CMC temperatures measured from these wire TC's were compared to that from the facility pyrometer and thin film TC's. There was no sign of TC delamination even after several hours exposure to 1200 C. The test results proved that this new technique can successfully attach wire TC's on CMC's and provide temperature data in hostile environments. The sensor fabrication process is less expensive and requires very little time compared to that of the thin film TC's. The same installation technique/process can also be applied to attach lead wires for thin film sensor systems.

  19. Thermocouples in an alternating magnetic field (AMF) for studying magnetic nanoparticle hyperthermia

    Science.gov (United States)

    Hartzell, S.; Boekelheide, Z.

    Magnetic nanoparticle hyperthermia, a method of cancer therapy, is currently a subject of active research. A critical parameter during therapy or laboratory research is the temperature of the system (tissue or nanoparticle suspension). Thermocouples are affordable and ubiquitous temperature sensors which could be used in this capacity; however, their metallic nature results in self-heating due to eddy currents when placed in an AMF. This presentation will quantitatively discuss calculations and measurements of the self-heating of three common types of thermocouples. Type T, K, and E thermocouples of both thin (40 gauge) and thick (20 gauge) wires were tested in a range of applied magnetic field magnitudes (235 kHz, 0-0.4 T rms). Among the thermocouples, all three types demonstrated large self-heating in 20 gauge wires. For the 40 gauge wires, type K showed large self-heating, while type T showed small but significant self-heating and type E showed no significant self-heating in comparison to the background. Our results indicate that thin type E thermocouples can be accurately used as temperature sensors in an AMF environment similar to the one used here, and type T thermocouples may be appropriate under conditions with lower magnetic field strength or frequency.

  20. ORTHOPEDIC LEG BRACE

    Science.gov (United States)

    Myers, William Neil (Inventor)

    2005-01-01

    Knee braces generally have been rigid in both the knee bending direction and in the knee straightening direction unless a manually operated release is incorporated in them to allow the knee to bend. Desirably a braced knee joint should effectively duplicate the compound, complex, actions of a normal knee. The key to knee braces is the knee joint housing. The housing herein carries a number of cam action pawls. with teeth adapted to engage the internal teeth of a ratchet ring mounted in the housing. Cam action return springs and the shape of the cam action pawl teeth allow rotation of the ratchet ring in a leg straightening direction while still supporting a load. The leg can then be extended during walking while at the same time being prevented by the cam action pawls from buckling in the knee bending direction.

  1. Restless legs syndrome.

    Science.gov (United States)

    Klingelhoefer, Lisa; Bhattacharya, Kalyan; Reichmann, Heinz

    2016-08-01

    Restless legs syndrome (RLS), also known as Willis-Ekbom disease (WED), is a common movement disorder characterised by an uncontrollable urge to move because of uncomfortable, sometimes painful sensations in the legs with a diurnal variation and a release with movement. The pathophysiology is only partially known and a genetic component together with dopaminergic and brain iron dysregulation plays an important role. Secondary causes for RLS need to be excluded. Treatment depends on the severity and frequency of RLS symptoms, comprises non-pharmacological (eg lifestyle changes) and pharmacological interventions (eg dopaminergic medication, alpha-2-delta calcium channel ligands, opioids) and relieves symptoms only. Augmentation is the main complication of long-term dopaminergic treatment of RLS. This article will provide a clinically useful overview of RLS with provision of diagnostic criteria, differential diagnoses, possible investigations and different treatment strategies with their associated complications. © 2016 Royal College of Physicians.

  2. Venous Leg Ulcers.

    Science.gov (United States)

    Vivas, Alejandra; Lev-Tov, Hadar; Kirsner, Robert S

    2016-08-02

    This issue provides a clinical overview of venous leg ulcers, focusing on prevention, diagnosis, treatment, and practice improvement. The content of In the Clinic is drawn from the clinical information and education resources of the American College of Physicians (ACP), including MKSAP (Medical Knowledge and Self-Assessment Program). Annals of Internal Medicine editors develop In the Clinic in collaboration with the ACP's Medical Education and Publishing divisions and with the assistance of additional science writers and physician writers.

  3. have a hollow leg

    Institute of Scientific and Technical Information of China (English)

    周立

    2003-01-01

    英语对话 A:We must prevent our family members from getting involved with drugs, really. B:That’s a sure thing.We must make sure that they never involve them- selves with that. A:By the way,does your husband drink a lot? B:Yeah.That’s the only thing that keeps worrying me.And he often boasts that he has a hollow leg and nobody can drink him under the ta- ble.

  4. Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels.

    Science.gov (United States)

    Dasgupta, Subhashish; Banerjee, Rupak K; Hariharan, Prasanna; Myers, Matthew R

    2011-02-01

    Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be made on the basis of the measurements. Thermocouple artifact due to viscous heating is one source of error. A second is the uncertainty regarding the position of the beam relative to the target location or the thermocouple junction, due to the error in positioning the beam at the junction. This paper presents a method for determining the location of the beam relative to a fixed pair of thermocouples. The localization technique reduces the uncertainty introduced by positioning errors associated with very narrow HIFU beams. The technique is presented in the context of an investigation into the effect of blood flow through large vessels on the efficacy of HIFU procedures targeted near the vessel. Application of the beam localization method allowed conclusions regarding the effects of blood flow to be drawn from previously inconclusive (because of localization uncertainties) data. Comparison of the position-adjusted transient temperature profiles for flow rates of 0 and 400ml/min showed that blood flow can reduce temperature elevations by more than 10%, when the HIFU focus is within a 2mm distance from the vessel wall. At acoustic power levels of 17.3 and 24.8W there is a 20- to 70-fold decrease in thermal dose due to the convective cooling effect of blood flow, implying a shrinkage in lesion size. The beam-localization technique also revealed the level of thermocouple artifact as a function of sonication time, providing investigators with an indication of the quality of thermocouple data for a given exposure time. The maximum artifact was found to be double the measured temperature rise, during initial few seconds of sonication.

  5. Effect of the Thermocouple on Measuring the Temperature Discontinuity at a Liquid-Vapor Interface.

    Science.gov (United States)

    Kazemi, Mohammad Amin; Nobes, David S; Elliott, Janet A W

    2017-07-18

    The coupled heat and mass transfer that occurs in evaporation is of interest in a large number of fields such as evaporative cooling, distillation, drying, coating, printing, crystallization, welding, atmospheric processes, and pool fires. The temperature jump that occurs at an evaporating interface is of central importance to understanding this complex process. Over the past three decades, thermocouples have been widely used to measure the interfacial temperature jumps at a liquid-vapor interface during evaporation. However, the reliability of these measurements has not been investigated so far. In this study, a numerical simulation of a thermocouple when it measures the interfacial temperatures at a liquid-vapor interface is conducted to understand the possible effects of the thermocouple on the measured temperature and features in the temperature profile. The differential equations of heat transfer in the solid and fluids as well as the momentum transfer in the fluids are coupled together and solved numerically subject to appropriate boundary conditions between the solid and fluids. The results of the numerical simulation showed that while thermocouples can measure the interfacial temperatures in the liquid correctly, they fail to read the actual interfacial temperatures in the vapor. As the results of our numerical study suggest, the temperature jumps at a liquid-vapor interface measured experimentally by using a thermocouple are larger than what really exists at the interface. For a typical experimental study of evaporation of water at low pressure, it was found that the temperature jumps measured by a thermocouple are overestimated by almost 50%. However, the revised temperature jumps are still in agreement with the statistical rate theory of interfacial transport. As well as addressing the specific application of the liquid-vapor temperature jump, this paper provides significant insight into the role that heat transfer plays in the operation of thermocouples

  6. Common Cold

    Science.gov (United States)

    ... nose, coughing - everyone knows the symptoms of the common cold. It is probably the most common illness. In the course of a year, people ... avoid colds. There is no cure for the common cold. For relief, try Getting plenty of rest ...

  7. Thermocouples Connection Problem Checking Method Analysis Based on PXIe Series Data Acquisition Card%基于PXIe系列数据采集卡的热电偶接线检查方法分析

    Institute of Scientific and Technical Information of China (English)

    王春意; 颜阳; 包志为

    2016-01-01

    介绍了热工水力实验热电偶使用方式及原理,PXIe系列数据采集卡冷端补偿原理。着重对不同接线方式产生的测量结果进行了理论分析,并通过实验验证了理论分析结果。进而提出如何对安装完成的热电偶进行系统全面的接线检查。%The principle of thermocouples used and thermal-hydraulic experiment, cold junction compensation principle PXIe serial data acquisition card. Focuses on the different ways of measuring results of theoretical analysis and experimental verification of results of the analysis. Presented how to check the comprehensive wiring system of thermocouple installation is complete.

  8. Differential diagnosis of leg ulcers.

    Science.gov (United States)

    Pannier, F; Rabe, E

    2013-03-01

    Leg and foot ulcers are symptoms of very different diseases. The aim of this paper is to demonstrate the differential diagnosis of leg ulcers. The majority of leg ulcers occur in the lower leg or foot. In non-venous ulcers the localization in the foot area is more frequent. The most frequent underlying disease is chronic venous disease. In 354 leg ulcers, Koerber found 75.25% venous leg ulcers, 3.66% arterial leg ulcers, 14.66% ulcers of mixed venous and arterial origin and 13.5% vasculitic ulcers. In the Swedish population of Skaraborg, Nelzen found a venous origin in 54% of the ulcer patients. Each leg ulcer needs a clinical and anamnestic evaluation. Duplex ultrasound is the basic diagnostic tool to exclude vascular anomalies especially chronic venous and arterial occlusive disease. Skin biopsies help to find a correct diagnosis in unclear or non-healing cases. In conclusion, chronic venous disease is the most frequent cause of leg ulcerations. Because 25% of the population have varicose veins or other chronic venous disease the coincidence of pathological venous findings and ulceration is very frequent even in non-venous ulcerations. Leg ulcers without the symptoms of chronic venous disease should be considered as non-venous.

  9. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    OpenAIRE

    LAURIE Mathias; FOURREZ Stéphane; FUETTERER Michael; LAPETITE Jean-Marc; SADLI M.; MORICE Ronan; FAILLEAU G

    2013-01-01

    During irradiation tests at high temperature failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. As instrumentation, in particular thermocouples are considered safety-relevant both for irradiation tests and for commercial reactors, JRC and THERMOCOAX joined forces to solve this issue by performing out-of-pile tests with thermocouples mimicking the environment encountered by high temperature reactor (HTR) in-core instrumentation. The objective was to screen innova...

  10. Long Term Out-of-pile Thermocouple Tests in Conditions Representative for Nuclear Gas-cooled High Temperature Reactors

    OpenAIRE

    LAURIE Mathias; FOURREZ Stephane; FUETTERER Michael; LAPETITE Jean-Marc

    2011-01-01

    During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remediate this problem, out-ofpile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of...

  11. Measurement of Thermocouple Time Constant%热电偶时间常数的测量

    Institute of Scientific and Technical Information of China (English)

    傅元; 董宇哲; 李德健; 董健

    2012-01-01

    为准确测量出热电偶的时间常数,根据热电偶对阶跃温度的响应,用单指数曲线描述过渡过程的数学模型,对记录的过渡过程曲线进行拟合,拟合后单指数曲线的时间常数就是被测热电偶的时间常数。对多种热电偶和同一热电偶的反复测试表明这种方法准确,相对于其它方法适应性更强。%In order to accurately measure the time constant of the thermocouple, according to the temperature of the thermocouple to a step response, single exponential curve with a mathematical model of the transition process described, record of the transition pro- cess of fitting curves, after fitting a single exponential curve is the measured time constant time constant thermocouples. A variety of thermocouples and thermocouple repeated the same test shows that this method is accurate, compared to other methods more adaptive.

  12. Establishment of the Co-C Eutectic Fixed-Point Cell for Thermocouple Calibrations at NIMT

    Science.gov (United States)

    Ongrai, O.; Elliott, C. J.

    2017-08-01

    In 2015, NIMT first established a Co-C eutectic temperature reference (fixed-point) cell measurement capability for thermocouple calibration to support the requirements of Thailand's heavy industries and secondary laboratories. The Co-C eutectic fixed-point cell is a facility transferred from NPL, where the design was developed through European and UK national measurement system projects. In this paper, we describe the establishment of a Co-C eutectic fixed-point cell for thermocouple calibration at NIMT. This paper demonstrates achievement of the required furnace uniformity, the Co-C plateau realization and the comparison data between NIMT and NPL Co-C cells by using the same standard Pt/Pd thermocouple, demonstrating traceability. The NIMT measurement capability for noble metal type thermocouples at the new Co-C eutectic fixed point (1324.06°C) is estimated to be within ± 0.60 K (k=2). This meets the needs of Thailand's high-temperature thermocouple users—for which previously there has been no traceable calibration facility.

  13. Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.

    Energy Technology Data Exchange (ETDEWEB)

    Nakos, James T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Suo-Anttila, Jill M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zepper, Ethan T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Koenig, Jerry J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Valdez, Vincent A. [ECI Inc., Albuquerque, NM (United States)

    2017-05-01

    Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .

  14. Leg cramps and restless legs syndrome during pregnancy.

    Science.gov (United States)

    Hensley, Jennifer G

    2009-01-01

    Sleep disturbance during pregnancy can result in excessive daytime sleepiness, diminished daytime performance, inability to concentrate, irritability, and the potential for an increased length of labor and increased risk of operative birth. Sleep disturbance may be the result of a sleep disorder, such as leg cramps, a common yet benign disorder, or restless legs syndrome, a sensorimotor disorder. Both disrupt sleep, are distressing to the pregnant woman, and mimic one another and other serious disorders. During pregnancy, up to 30% of women can be affected by leg cramps, and up to 26% can be affected by restless legs syndrome.

  15. Textiloma in the leg

    Directory of Open Access Journals (Sweden)

    Patel Amol

    2007-01-01

    Full Text Available Textiloma is defined as a tumor formed due to retained gauze. It is rarely reported in the musculoskeletal system. We are presenting a case with a soft tissue swelling over the lateral aspect of the lower third of the leg, come for implant removal of the distal tibia and fibular fracture. We removed the soft tissue mass enbloc thinking it to be a benign tumor. On cutting the mass on the operation table, a gauze piece encased by fibrous tissue was found. Textiloma can present as tumoral forms and can mimic as a pseudo-tumor.

  16. Thermocouples--the Arizona experience with in-house manufactured probes.

    Science.gov (United States)

    Anhalt, D; Hynynen, K

    1992-01-01

    The performance of several different types of multisensor thermocouple probes have been tested to determine the feasibility of each type for use in the hyperthermia clinic. All of the probes tested were manufactured in-house, and a detailed description of the construction process will be presented. The overall performance of the probes in terms of robustness, calibration, conduction errors, and response time will be described. In particular, this study describes our experience with in-house manufactured thermocouples over the past several years. The results indicate that when strict quality assurance guidelines are followed, in-house manufactured thermocouples perform satisfactorily--thereby providing an alternative to purchasing probes and measurement systems from commercial vendors if the proper resources are available.

  17. Direct measurements of electrocaloric effect in ferroelectrics using thin-film thermocouples

    Science.gov (United States)

    Matsushita, Yuji; Nochida, Atsushi; Yoshimura, Takeshi; Fujimura, Norifumi

    2016-10-01

    A direct measurement method for investigating the electrocaloric (EC) effect was developed using a thin-film thermocouple deposited on samples. A T-type thin-film thermocouple was fabricated by RF magnetron sputtering at room temperature. Two types of measurement were carried out using rectangular pulses and sine waves with a DC offset. The EC coefficients (ΔT/ΔE) of BaTiO3 ceramics were determined as 0.35 × 10-6 and 0.48 × 10-6 K·m/V in the measurements at Curie temperature. The EC temperature change of a (Ba0.9,Ca0.1)TiO3 thin film was measured using sine waves with the DC offset. The EC coefficient was 0.0018 × 10-6 K·m/V at room temperature. These results suggest that thin-film thermocouples are useful for the direct measurement of the EC effect.

  18. Printed organic conductive polymers thermocouples in textile and smart clothing applications.

    Science.gov (United States)

    Seeberg, Trine M; Røyset, Arne; Jahren, Susannah; Strisland, Frode

    2011-01-01

    This work reports on an experimental investigation of the potential of using selected commercially available organic conductive polymers as active ingredients in thermocouples printed on textiles. Poly(3, 4-ethylenedioxythiophene): poly(4 styrenesulfonate) (PEDOT:PSS) and polyaniline (PANI) were screen printed onto woven cotton textile. The influence of multiple thermocycles between 235 K (-38 °C) and 350 K (+77 °C) on resistivity and thermoelectric properties was examined. The Seebeck coefficients of PEDOT:PSS and PANI were found to be about +18 μV/K and +15 uV/K, respectively, when "metal-polymer" thermocouples were realized by combining the polymer with copper. When "polymer-polymer" thermocouples were formed by combining PEDOT:PSS and PANI, a thermoelectric voltage of about +10 μV/K was observed. A challenge recognized in the experiments is that the generated voltage exhibited drift and fluctuations.

  19. Thermocouple error correction for measuring the flame temperature with determination of emissivity and heat transfer coefficient.

    Science.gov (United States)

    Hindasageri, V; Vedula, R P; Prabhu, S V

    2013-02-01

    Temperature measurement by thermocouples is prone to errors due to conduction and radiation losses and therefore has to be corrected for precise measurement. The temperature dependent emissivity of the thermocouple wires is measured by the use of thermal infrared camera. The measured emissivities are found to be 20%-40% lower than the theoretical values predicted from theory of electromagnetism. A transient technique is employed for finding the heat transfer coefficients for the lead wire and the bead of the thermocouple. This method does not require the data of thermal properties and velocity of the burnt gases. The heat transfer coefficients obtained from the present method have an average deviation of 20% from the available heat transfer correlations in literature for non-reacting convective flow over cylinders and spheres. The parametric study of thermocouple error using the numerical code confirmed the existence of a minimum wire length beyond which the conduction loss is a constant minimal. Temperature of premixed methane-air flames stabilised on 16 mm diameter tube burner is measured by three B-type thermocouples of wire diameters: 0.15 mm, 0.30 mm, and 0.60 mm. The measurements are made at three distances from the burner tip (thermocouple tip to burner tip/burner diameter = 2, 4, and 6) at an equivalence ratio of 1 for the tube Reynolds number varying from 1000 to 2200. These measured flame temperatures are corrected by the present numerical procedure, the multi-element method, and the extrapolation method. The flame temperatures estimated by the two-element method and extrapolation method deviate from numerical results within 2.5% and 4%, respectively.

  20. Thermocouple Rakes for Measuring Boundary Layer Flows Extremely Close to Surface

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Blaha, Charles A.

    2001-01-01

    Of vital interest to aerodynamic researchers is precise knowledge of the flow velocity profile next to the surface. This information is needed for turbulence model development and the calculation of viscous shear force. Though many instruments can determine the flow velocity profile near the surface, none of them can make measurements closer than approximately 0.01 in. from the surface. The thermocouple boundary-layer rake can measure much closer to the surface than conventional instruments can, such as a total pressure boundary layer rake, hot wire, or hot film. By embedding the sensors (thermocouples) in the region where the velocity is equivalent to the velocity ahead of a constant thickness strut, the boundary-layer flow profile can be obtained. The present device fabricated at the NASA Glenn Research Center microsystem clean room has a heater made of platinum and thermocouples made of platinum and gold. Equal numbers of thermocouples are placed both upstream and downstream of the heater, so that the voltage generated by each pair at the same distance from the surface is indicative of the difference in temperature between the upstream and downstream thermocouple locations. This voltage differential is a function of the flow velocity, and like the conventional total pressure rake, it can provide the velocity profile. In order to measure flow extremely close to the surface, the strut is made of fused quartz with extremely low heat conductivity. A large size thermocouple boundary layer rake is shown in the following photo. The latest medium size sensors already provide smooth velocity profiles well into the boundary layer, as close as 0.0025 in. from the surface. This is about 4 times closer to the surface than the previously used total pressure rakes. This device also has the advantage of providing the flow profile of separated flow and also it is possible to measure simultaneous turbulence levels within the boundary layer.

  1. Thermocouple error correction for measuring the flame temperature with determination of emissivity and heat transfer coefficient

    Science.gov (United States)

    Hindasageri, V.; Vedula, R. P.; Prabhu, S. V.

    2013-02-01

    Temperature measurement by thermocouples is prone to errors due to conduction and radiation losses and therefore has to be corrected for precise measurement. The temperature dependent emissivity of the thermocouple wires is measured by the use of thermal infrared camera. The measured emissivities are found to be 20%-40% lower than the theoretical values predicted from theory of electromagnetism. A transient technique is employed for finding the heat transfer coefficients for the lead wire and the bead of the thermocouple. This method does not require the data of thermal properties and velocity of the burnt gases. The heat transfer coefficients obtained from the present method have an average deviation of 20% from the available heat transfer correlations in literature for non-reacting convective flow over cylinders and spheres. The parametric study of thermocouple error using the numerical code confirmed the existence of a minimum wire length beyond which the conduction loss is a constant minimal. Temperature of premixed methane-air flames stabilised on 16 mm diameter tube burner is measured by three B-type thermocouples of wire diameters: 0.15 mm, 0.30 mm, and 0.60 mm. The measurements are made at three distances from the burner tip (thermocouple tip to burner tip/burner diameter = 2, 4, and 6) at an equivalence ratio of 1 for the tube Reynolds number varying from 1000 to 2200. These measured flame temperatures are corrected by the present numerical procedure, the multi-element method, and the extrapolation method. The flame temperatures estimated by the two-element method and extrapolation method deviate from numerical results within 2.5% and 4%, respectively.

  2. Technical note. Use of CT in the placement of heat monitoring thermocouples for hyperthermia therapy.

    Science.gov (United States)

    Eftekhari, F; Bernardino, M E; Headley, D L; Corry, P M

    1981-12-01

    In 12 cancer patients undergoing hyperthermia therapy, computed tomography (CT) was used for placement of thermocouples within the tumoral tissue. Tumors were located in the thorax, abdomen, and pelvis. Computed tomography provided accurate angulation of the introduction angiocatheter as well as the ability to choose the shortest and safest path. The cross-sectional display was especially helpful in placing the heat monitoring thermocouple within the active part of the tumor rather than a necrotic portion. It is our opinion that CT is superior to fluoroscopy in this regard.

  3. Modeling of the polymerization process of the insulating layer of cable thermocouples

    Directory of Open Access Journals (Sweden)

    Olga Iashutina

    2017-01-01

    Full Text Available A mathematical model describing the main physical processes occurring during thermal processing of cable thermocouples (CT during their production is presented. The polymerization of the insulating layer is taken into account in the conditions of its intense heating. The developed mathematical model allows to carry out calculations of heat transfer processes under the conditions of substantial heterogeneity of cable thermocouple structure. The computational experiments carried out have established significant differences in the characteristics of heat transfer in CT in the presence of thermoelectrodes with differing thermophysical characteristics.

  4. A Study of the Behavior Characteristics for K-type Thermocouple

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Songhae; Kim, Yongsik; Lee, Sooill [KHNP Central Research Institute, Daejeon (Korea, Republic of); Kim, Sungjin [Woojin inc., Osan (Korea, Republic of); Lyou, Jooon [Chungnam National Univ., Daejeon (Korea, Republic of)

    2014-05-15

    K-type thermocouple is widely used in nuclear power plants (NPP) and they provide reliable service. Generally, the thermocouple assembly is the finished product and usually only nondestructive tests are performed on the assembly, whereas destructive tests are confined to selected bulk cable specimens. This K-type thermocouple has been used representatively in the In-Core Instrument Assembly (ICI) in the nuclear power plants. The ICI consists of five rhodium emitter detectors that provide information on the thermal power for the core and one K-type thermocouple made with two cables (Chromel-Alumel) that provides the temperature of core exit (CET). Generally, the quantity of the ICI is absolutely different according to the number of fuel assemblies in the NPP. In the case of SKN 3 and 4, they were designed to the 61 ICI to provide information on the core cooling to the inadequate core cooling monitoring system (ICCMS). This measured temperature could be also used to check the entry condition of severe accidents. The technology of the TFDR is a generic skill to detect the fault position of the cable. In-core Instruments (ICIs) were used to detect the Core Exit Temperature (CET) in a reactor. This measured temperature was also used to check the entry condition of severe accidents. However, if a serious accident occurs, the upper portion of the core is damaged. This instrument has not been available. This paper illustrates the estimation possibility for the status of molten core through the high-temperature characteristics test of k-type thermocouple. It turns out that it is possible to measure the k-type thermocouple up to 1350 .deg. C degrees before melting during insertion into the melting furnace. Additionally, in order to measure a high temperature of 2000 .deg. C or more, the replacement possibility of k-type thermocouple was evaluated. However the tungsten-rhenium thermocouple is impossible to use in the detection of temperature at the in-core because of the

  5. Measurement and simulation of thermoelectric efficiency for single leg.

    Science.gov (United States)

    Hu, Xiaokai; Yamamoto, Atsushi; Ohta, Michihiro; Nishiate, Hirotaka

    2015-04-01

    Thermoelectric efficiency measurements were carried out on n-type bismuth telluride legs with the hot-side temperature at 100 and 150°C. The electric power and heat flow were measured individually. Water coolant was utilized to maintain the cold-side temperature and to measure heat flow out of the cold side. Leg length and vacuum pressure were studied in terms of temperature difference across the leg, open-circuit voltage, internal resistance, and heat flow. Finite-element simulation on thermoelectric generation was performed in COMSOL Multiphysics, by inputting two-side temperatures and thermoelectric material properties. The open-circuit voltage and resistance were in good agreement between the measurement and simulation. Much larger heat flows were found in measurements, since they were comprised of conductive, convective, and radiative contributions. Parasitic heat flow was measured in the absence of bismuth telluride leg, and the conductive heat flow was then available. Finally, the maximum thermoelectric efficiency was derived in accordance with the electric power and the conductive heat flow.

  6. Differentiating nocturnal leg cramps and restless legs syndrome.

    Science.gov (United States)

    Rana, Abdul Qayyum; Khan, Fatima; Mosabbir, Abdullah; Ondo, William

    2014-07-01

    Leg pain and discomfort are common complaints in any primary physician's clinic. Two common causes of pain or discomfort in legs are nocturnal leg cramps (NLC) and restless leg syndrome (RLS). NLC present as painful and sudden contractions mostly in part of the calf. Diagnosis of NLC is mainly clinical and sometimes involves investigations to rule out other mimics. RLS is a condition characterized by the discomfort or urge to move the lower limbs, which occurs at rest or in the evening/night. The similarity of RLS and leg cramps poses the issue of errors in diagnosing and differentiating the two. In this paper we review the pathopysiology of each entity and their diagnosis as well as treatment. The two conditions are then compared to appreciate the differences and similarities. Finally, suggestions are recommended for complete assessment.

  7. [Restless-legs syndrome].

    Science.gov (United States)

    Karroum, E; Konofal, E; Arnulf, I

    2008-01-01

    Restless-legs syndrome (RLS) is a sensorimotor disorder, characterized by an irresistible urge to move the legs usually accompanied or caused by uncomfortable and unpleasant sensations. It begins or worsens during periods of rest or inactivity, is partially or totally relieved by movements and is exacerbated or occurs at night and in the evening. RLS sufferers represent 2 to 3% of the general population in Western countries. Supportive criteria include a family history, the presence of periodic-leg movements (PLM) when awake or asleep and a positive response to dopaminergic treatment. The RLS phenotypes include an early onset form, usually idiopathic with a familial history and a late onset form, usually secondary to peripheral neuropathy. Recently, an atypical RLS phenotype without PLM and l-DOPA resistant has been characterized. RLS can occur in childhood and should be distinguished from attention deficit/hyperactivity disorder, growing pains and sleep complaints in childhood. RLS should be included in the diagnosis of all patients consulting for sleep complaints or discomfort in the lower limbs. It should be differentiated from akathisia, that is, an urge to move the whole body without uncomfortable sensations. Polysomnographic studies and the suggested immobilization test can detect PLM. Furthermore, an l-DOPA challenge has recently been validated to support the diagnosis of RLS. RLS may cause severe-sleep disturbances, poor quality of life, depressive and anxious symptoms and may be a risk factor for cardiovascular disease. In most cases, RLS is idiopathic. It may also be secondary to iron deficiency, end-stage renal disease, pregnancy, peripheral neuropathy and drugs, such as antipsychotics and antidepressants. The small-fiber neuropathy can mimic RLS or even trigger it. RLS is associated with many neurological and sleep disorders including Parkinson's disease, but does not predispose to these diseases. The pathophysiology of RLS includes an altered brain

  8. Klinefelter Syndrome With Leg Ulcers

    Directory of Open Access Journals (Sweden)

    Narendra G

    1999-01-01

    Full Text Available Leg ulcers are frequently caused by venous insufficiency, arterial insufficiency, neuropathy, or a combination of these factors. Klinefelter syndrome in association with chronic leg ulcers have been reported earlier. We report a case of Klinefelter syndrome with non- healing ulcer. The diagnosis of the Klinefelter syndrome was confirmed by karyotyping.

  9. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M. [European Commission, Joint Research Centre, Inst. for Energy, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Fourrez, S. [THERMOCOAX SAS, BP 26, Planquivon, F-61438 Flers Cedex (France); Fuetterer, M. A.; Lapetite, J. M. [European Commission, Joint Research Centre, Inst. for Energy, P.O. Box 2, NL-1755 ZG Petten (Netherlands)

    2011-07-01

    During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remedy this problem, out-of-pile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of thermocouples embedded in graphite (mainly conventional Type N thermocouples and thermocouples with innovative sheaths) in a dedicated furnace with helium flushing. Performance indicators such as thermal drift, insulation and loop resistance were monitored and compared to those from conventional Type N thermocouples. Several parameters were investigated: niobium sleeves, bending, thickness, sheath composition, temperature as well as the chemical environment. After the tests, Scanning Electron Microscopy (SEM) examinations were performed to analyze possible local damage in wires and in the sheath. The present paper describes the two experiments, summarizes results and outlines further work, in particular to further analyze the findings and to select suitable thermocouples for qualification under irradiation. (authors)

  10. Cold Sores

    Science.gov (United States)

    ... Previous Next Related Articles: Canker and Cold Sores Aloe Vera May Help Relieve Mouth Sores Canker Sore or Cold Sore? Mouth Sores: Caused By Student Stress? games Home | InfoBites | Find a Dentist | Your Family's Oral Health | Newsroom | RSS About AGD | Contact AGD | Site Map | ...

  11. Biomechanics of Counterweighted One-Legged Cycling.

    Science.gov (United States)

    Elmer, Steven J; McDaniel, John; Martin, James C

    2016-02-01

    One-legged cycling has served as a valuable research tool and as a training and rehabilitation modality. Biomechanics of one-legged cycling are unnatural because the individual must actively lift the leg during flexion, which can be difficult to coordinate and cause premature fatigue. We compared ankle, knee, and hip biomechanics between two-legged, one-legged, and counterweighted (11.64 kg) one-legged cycling. Ten cyclists performed two-legged (240 W), one-legged (120 W), and counterweighted one-legged (120 W) cycling (80 rpm). Pedal forces and limb kinematics were recorded to determine work during extension and flexion. During counterweighted one-legged cycling relative ankle dorsiflexion, knee flexion, and hip flexion work were less than one-legged but greater than two-legged cycling (all P cycling were greater than one-legged but less than two-legged cycling (all P cycling reduced but did not eliminate differences in joint flexion and extension actions between one- and two-legged cycling. Even with these differences, counterweighted one-legged cycling seemed to have advantages over one-legged cycling. These results, along with previous work highlighting physiological characteristics and training adaptations to counterweighted one-legged cycling, demonstrate that this exercise is a viable alternative to one-legged cycling.

  12. Genetics Home Reference: restless legs syndrome

    Science.gov (United States)

    ... Johns Hopkins Medicine MalaCards: restless legs syndrome Merck Manual Professional Version Patient Support and Advocacy Resources (3 links) European Alliance for Restless Legs Syndrome National Organization for Rare Disorders (NORD) Restless Leg Syndrome Foundation ...

  13. Performance and Durability of Thin Film Thermocouple Array on a Porous Electrode.

    Science.gov (United States)

    Guk, Erdogan; Ranaweera, Manoj; Venkatesan, Vijay; Kim, Jung-Sik

    2016-08-23

    Management of solid oxide fuel cell (SOFC) thermal gradients is vital to limit thermal expansion mismatch and thermal stress. However, owing to harsh operation conditions of SOFCs and limited available space in stack configuration, the number of techniques available to obtain temperature distribution from the cell surface is limited. The authors previously developed and studied a thermocouple array pattern to detect surface temperature distribution on an SOFC in open circuit conditions. In this study, the performance in terms of mechanical durability and oxidation state of the thin film thermoelements of the thermocouple array on the porous SOFC cathode is investigated. A thin-film multi-junction thermocouple array was sputter deposited using a magnetron sputter coater. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) characterisation techniques were carried out to understand characteristics of the thin film before and after temperature (20 °C-800 °C) measurement. Temperature readings from the sensor agreed well with the closely placed commercial thermocouple during heating segments. However, a sensor failure occurred at around 350 °C during the cooling segment. The SEM and XPS tests revealed cracks on the thin film thermoelements and oxidation to the film thickness direction.

  14. Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography.

    Science.gov (United States)

    Fernandes, Alex de Andrade; Amorim, Paulo Roberto dos Santos; Brito, Ciro José; de Moura, Anselmo Gomes; Moreira, Danilo Gomes; Costa, Carlos Magno Amaral; Sillero-Quintana, Manuel; Marins, João Carlos Bouzas

    2014-02-01

    Measuring skin temperature (TSK) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record TSK involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure TSK, and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MTSK) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland-Altman plots showed poor agreement between the MTSK obtained using thermocouples and those using IRT. The averaged error was -0.75 °C during pre-exercise, 1.22 °C during exercise and -1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [-0.80 to 0.85]) and post-exercise (ICC = 0.35 [-1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MTSK measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement.

  15. Temperature measurement artefacts of thermocouples and fluoroptic probes during laser irradiation at 810 nm.

    Science.gov (United States)

    Reid, A D; Gertner, M R; Sherar, M D

    2001-06-01

    This study examined the artefact induced in temperature measurements made with thermocouples and Luxtron fluoroptic probes in the presence of infrared radiation. Localized heating was created using a continuous-wave, 810 nm diode laser system emitting 2.0 W from a cylindrical diffusing optical fibre, in air, water and an agar-albumin phantom. The temperature was measured every 1.0 s for 10 to 150 s, with both a thermocouple and a Luxtron fluoroptic probe at distances of 2, 3, 4, 5, 6 and 7 mm from the cylindrical diffusing tip. In all cases, the fluoroptic probe recorded a higher temperature than the thermocouple during laser irradiation. The difference in measured temperatures between the Luxtron probe and the thermocouple ranged from 1.6 degrees C to 18.8 degrees C in air, from 0.3 degrees C to 10.2 degrees C in water, and from 1.4 degrees C to 10.1 degrees C in phantom, depending on the distance of the probe from the laser source. The results suggest that in the presence of laser irradiation, self-heating of the Luxtron probe induces a significant artefact in temperature measurements at distances less than 4 mm from the source fibre. As a result, fluoroptic probes may not be suitable for monitoring tissue temperature for treatments when laser irradiation is present if sensors are located close to the fibre tip (<4 mm).

  16. Minimizing the self-heating artefacts due to the microwave irradiation of thermocouples.

    Science.gov (United States)

    Dunscombe, P B; Constable, R T; McLellan, J

    1988-01-01

    The self-heating of metallic thermocouples in therapeutic microwave fields has long been recognized as a source of temperature artefacts in clinical hyperthermia dosimetry. We examine several techniques by which the probe and tissue heating artefacts resulting from self-heating may be quantitatively assessed, and discuss these in the context of their applicability to clinical hyperthermia.

  17. Performance and Durability of Thin Film Thermocouple Array on a Porous Electrode

    Science.gov (United States)

    Guk, Erdogan; Ranaweera, Manoj; Venkatesan, Vijay; Kim, Jung-Sik

    2016-01-01

    Management of solid oxide fuel cell (SOFC) thermal gradients is vital to limit thermal expansion mismatch and thermal stress. However, owing to harsh operation conditions of SOFCs and limited available space in stack configuration, the number of techniques available to obtain temperature distribution from the cell surface is limited. The authors previously developed and studied a thermocouple array pattern to detect surface temperature distribution on an SOFC in open circuit conditions. In this study, the performance in terms of mechanical durability and oxidation state of the thin film thermoelements of the thermocouple array on the porous SOFC cathode is investigated. A thin-film multi-junction thermocouple array was sputter deposited using a magnetron sputter coater. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) characterisation techniques were carried out to understand characteristics of the thin film before and after temperature (20 °C–800 °C) measurement. Temperature readings from the sensor agreed well with the closely placed commercial thermocouple during heating segments. However, a sensor failure occurred at around 350 °C during the cooling segment. The SEM and XPS tests revealed cracks on the thin film thermoelements and oxidation to the film thickness direction. PMID:27563893

  18. 基于K型热电偶的高精度测温放大电路设计%High Precision Temperature Measurement Based on K Type Thermocouple Ampliifer Circuit Design

    Institute of Scientific and Technical Information of China (English)

    唐友明; 刘丹; 何巨龙

    2016-01-01

    针对K型热电偶输出电压为微伏级别,本文设计了一种基于K型热电偶测温的放大电路。该设计通过LM35温度传感器对冷端进行了温度补偿,放大电路采用集成放大芯片AD7523,具有最高放大256倍的增益,采用高精度16位ADC转换芯片ADS1148,使用STC90C58AD单片机作为主控芯片,对K型热电偶进行了线性拟合,通过驱动LCD1602液晶对温度进行显示。%In view of the small output signal of K type thermocouple in microvolt level, In this paper design a kind of amplifier circuit based on K type thermocouple temperature measurement. The design of the cold junction compensation through the LM35 temperature sensor temperature compensation, amplifying circuit adopts integrated amplifier chip AD7523, it has the highest gain magnified 256 times, with high precision ADC conversion chip ADS1148, use STC90C58AD single-chip microcomputer as the master control chip, has carried on the linear fitting to K type thermocouple, through LCD1602 LCD display of temperature.

  19. Simulation of Thin Film Thermocouple for High Temperature Measurement Applicable to Missiles

    Directory of Open Access Journals (Sweden)

    Manoj Kumar Sonker

    2015-09-01

    Full Text Available Thermocouples have been extensively used for the measurement of temperature since the advent of seebeck effect. Numerous sensors have been developed for temperature measurement, yet measurement of high temperature flowing fluid has been a challenging task. For the measurement of static temperature the measuring device should travel with the fluid at the same speed without disturbing the flow, which is quite unrealistic. So indirect determination of static temperature of flowing fluid is done by using thermocouple exposed into the flowing fluid. Other sensors available for high temperature measurement may lead to problems like resistance in the flow path of fluid which changes the structural dynamics. Thin film thermocouple (TFTC based on W-W26Re for super high temperature measurement has been investigated which can be used in missiles for surface temperature measurement of nozzle and rocket interior surface. TFTC does not cause disruption in the flow path with maintaining structural integrity. The W-W26Re thermocouple offers advantage of higher seebeck coefficient at high temperature i.e. above 750 K, and usability in vacuum, inert and hydrogen atmosphere. Zirconia Fiber has been proposed as insulation protection material over thermocouple. Modelling and simulation of the TFTC for the temperature range 300 K - 2900 K has been presented. FEA model using PDE has been presented to implement heat equation, current balance  quation, Gauss theorem and Neumann boundary condition. The expected voltage production on exposed temperature gradient has been studied.

  20. Restless legs syndrome: literature review

    Directory of Open Access Journals (Sweden)

    Emmanouil Symvoulakis

    Full Text Available Restless legs syndrome is a distressing condition, with negative effects on sleep and daytime activities that affect personal, family and occupational life. The overall impact of restless legs syndrome on quality of life is comparable to that of chronic and frustrating conditions such as depression and diabetes. Misdiagnosis and inappropriate treatment may increase patients' suffering in terms of uncertainty, overuse or misuse of care services and lack of trust. Presenting a synthesis of the main topics in the literature on restless legs syndrome facilitates for a better understanding and its management in primary care settings.

  1. Restless legs syndrome

    Directory of Open Access Journals (Sweden)

    Ovallath S

    2012-10-01

    Full Text Available Sujith Ovallath, P DeepaJames Parkinson's Movement Disorder Research Centre, Kannur Medical College, Kerala, IndiaBackground: Restless legs syndrome (RLS is a common sleep-related disorder characterized by abnormal sensation and an urge to move the lower limbs. Symptoms occur at rest in the evening or at night, and they are alleviated by moving the affected extremity or by walking. Although the exact etiopathogenesis of RLS remains elusive, the rapid improvement of symptoms with dopaminergic agents suggests that dopaminergic system dysfunction may be a basic mechanism. Dopaminergic agents are the best-studied agents, and are considered first-line treatment of RLS.Objective: To review the diagnostic criteria, clinical features, etiopathogenesis, and the treatment options of RLS.Methods: The suggestions are based on evidence from studies published in peer-reviewed journals, or upon a comprehensive review of the medical literature.Results/conclusion: Extensive data are available for proving the link between the dopaminergic system and RLS. A possible genetic link also has been studied extensively. Dopamine agonists, especially pramipexole and ropinirole, are particularly useful in the treatment of RLS. Pharmacological treatment should however be limited to those patients who suffer from clinically relevant RLS with impaired sleep quality or quality of life.Keywords: dopamine, levodopa, pramipexole

  2. Man with leg rash.

    Science.gov (United States)

    Hwang, Michael Huynh; Khesbak, Ziyad; Liu, Yiju Teresa

    2017-10-01

    A 51-year-old male presented to the ED with a rash to his left thigh (figure 1) with erythema, swelling and pain. He endorsed paraesthesias, pruritus, fevers, vomiting and diarrhoea. Initial vitals were unremarkable. He was well appearing with an 8×8 cm violaceous patch on his left medial thigh with vesicles, surrounding erythema and induration with a second, smaller lesion on the right thigh. Both rashes were extremely tender.emermed;34/10/686/F1F1F1Figure 1Erythematosus and vesicular rash in bilateral legs.A bedside ultrasound image of the rash was obtained (figure 2).emermed;34/10/686/F2F2F2Figure 2Bedside ultrasound of rash. What is the most likely cause of the patient's rash?A. Herpes zosterB. CellulitisC. Necrotising fasciitisD. Bullous pemphigoid. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Cell integrated multi-junction thermocouple array for solid oxide fuel cell temperature sensing: N+1 architecture

    Science.gov (United States)

    Ranaweera, Manoj; Kim, Jung-Sik

    2016-05-01

    Understanding the cell temperature distribution of solid oxide fuel cell (SOFC) stacks during normal operation has multifaceted advantages in performance and degradation studies. Present efforts on measuring temperature from operating SOFCs measure only the gas channel temperature and do not reveal the cell level temperature distribution, which is more important for understanding a cell's performance and its temperature-related degradation. The authors propose a cell-integrated, multi-junction thermocouple array for in-situ cell surface temperature monitoring of an operational SOFC. The proposed thermocouple array requires far fewer numbers of thermoelements than that required by sets of thermocouples for the same number of temperature sensing points. Hence, the proposed array causes lower disturbance to cell performance than thermocouples. The thermoelement array was sputter deposited on the cathode of a commercial SOFC using alumel (Ni:Al:Mn:Si - 95:2:2:1 by wt.) and chromel (Ni:Cr - 90:10 by wt.). The thermocouple array was tested in a furnace over the entire operating temperature range of a typical SOFC. The individual sensing points of the array were shown to measure temperature independently from each other with equivalent accuracy to a thermocouple. Thus, the concept of multi-junction thermocouples is experimentally validated and its stability on a porous SOFC cathode is confirmed.

  4. [Restless legs syndrome - a review].

    Science.gov (United States)

    Sveinsson, Olafur Arni; Sigurdsson, Albert Pall

    2012-01-01

    Restless legs syndrome (RLS) is a common disorder with a prevalence between 10-20% in Iceland. There are two forms of RLS, idiopathic and secondary. Symptom onset of RLS before the age of 45 suggests an idiopathic form with no known underlying cause but inheritance. Symptom onset after age of 45 indicates a secondary form with an underlying cause without inheritance. Causes for secondary forms are for example: iron depletion, uraemia and polyneuropathy. Symptoms of RLS are uncomfortable and unpleasant deep sensations in the legs that are felt at rest, accompanied by an urge to move the legs, typically just before sleep. Accompanying RLS is a sleep disturbance that can lead to daytime somnolence, decreased quality of life, poor concentration, memory problems, depression and decreased energy. Dopamine agonists are currently the first line treatment for RLS. restless legs, periodic limb movements, sleep disturbance, dopamine agonists.

  5. Restless leg syndrome in pregnancy.

    Science.gov (United States)

    Grover, Aarti; Clark-Bilodeau, Courtney; D'Ambrosio, Carolyn M

    2015-09-01

    Restless leg syndrome, more recently renamed Willis-Ekbom disease, is a condition that disrupts sleep and occurs more frequently in the pregnant population. We present a 39-year-old woman with restless legs syndrome in the third trimester and discuss the epidemiology, pathophysiology and therapeutic options in the pregnant population while highlighting the challenges posed by the lack of safety data of approved drugs.

  6. Development of the thermocouple spot welder%热电偶点焊机的研制

    Institute of Scientific and Technical Information of China (English)

    王立冬; 周旭东

    2011-01-01

    热电偶是一种常用的测温元件,而传统的热电偶在焊接时由于本身裸露在空气中,试样与热电偶之间的焊点及临近区域难免被氧化,这样不仅降低了焊点的牢固性而且对测温的准确性也有一定的影响.为解决上述问题,设计和研制了焊接热电偶的专用设备--热电偶点焊机,该设备除了采用传统的储能式点焊机的基本原理外,在焊接时还采用了氩气保护,有效的解决了上述问题.并且对直径为0.2 mm镍铬-镍铝热电偶(K型热电偶)进行了焊接实验测试,通过在显微镜下观察焊点及附近区域的焊接效果结果表明,用本设备焊接的热电偶焊接效果良好而且有效地降低了焊点及附近区域的氧化现象.%Thermocouple is a kind of common temperature-measuring elements. However,While the traditional thermocouple being weld,due to bating the thermocouple itself in the air,there is no way to avoid the oxidation between sample and the thermocouple and the surrounding area. Thereby it not only reduce the soundness of welding spot,but also affects the accaracy of temperature measurement.In order to solve the mentioned problem,we have designed and manufactured a spot welding machine-Thermocouple Spot Welding,which specialize in weldimg the thermocouple.In addition to using the basic principle of traditional energy storage type spot welding machine,the protection of Ar is apphed,and it solve the mentioned problem effectively. By doing the welding test on the 0.2 mm in diameter nickel-based thermocouple(K-type), viewing welding spot under a microscope, the results show that oxidation phenomenon has been reduced effectively and the the effect of welding is so good with using this machine.

  7. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M., E-mail: mathias.laurie@ec.europa.eu [European Commission, Joint Research Centre, Institut für Transurane, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Fourrez, S. [THERMOCOAX SAS, Rue du Pré Neuf, 61100 Saint Georges des Groseillers (France); Fütterer, M.A.; Lapetite, J.M. [European Commission, Joint Research Centre, Institut für Transurane, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Sadli, M.; Morice, R.; Failleau, G. [Laboratoire commun de métrologie LNE-Cnam, 61 rue du Landy, F-92310 Saint-Denis (France)

    2014-05-01

    During irradiation tests at high temperature failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. As instrumentation, in particular thermocouples are considered safety-relevant both for irradiation tests and for commercial reactors, JRC and THERMOCOAX joined forces to solve this issue by performing out-of-pile tests with thermocouples mimicking the environment encountered by high temperature reactor (HTR) in-core instrumentation. The objective was to screen innovative sheathed thermocouples which would consecutively be tested under irradiation. Two such screening tests have been performed in high temperature environment (i.e. temperature in the range 1100–1150 °C) with purposely contaminated helium atmosphere (mainly CH{sub 4}, CO, CO{sub 2}, O{sub 2} impurities) representative for high temperature reactor carburizing atmospheres. The first set of thermocouples embedded in graphite (mainly conventional N type thermocouples and thermocouples with innovative sheaths) was tested in a dedicated furnace at THERMOCOAX lab with helium flushing. The second out-of-pile test at JRC with a partly different set of thermocouples replicated the original test for comparison. Performance indicators such as thermal drift, insulation resistance and loop resistance were monitored. Through these long-term screening tests the effect of several parameters were investigated: niobium sleeves, bending, diameter, sheath composition as well as the chemical environment. SEM examinations were performed to analyze local damage (bending zone, sheath). The present paper describes the two tests, sums up data collected during these tests in terms of thermocouple behavior and describes further instrumentation testing work with fixed point mini cells for qualification under irradiation.

  8. Restless legs syndrome.

    Science.gov (United States)

    Miletić, Vladimir; Relja, Maja

    2011-12-01

    Being of the most frequent causes of insomnia, which in the end leads to chronic fatigue, inadequate performance of daily activities, and serious disruption of quality of living, restless legs syndrome (RLS) is nowadays not only a serious medical problem but a socio-economical one as well. Prevalence of the disorder in general population is estimated at 5 to 15%. Family history is positive in over 50% of idiopathic RLS patients which points to genetic basis of the disorder. The characteristics of the secondary or acquired form of RLS are symptoms that start later in life as well as a rapid progression of the disease. On the other hand, idiopathic RLS more often starts at a younger age and the prognoses are better. Over twenty disorders and conditions are brought in connection with secondary RLS. Although the cause of primary RLS is still unknown, there is a strong connection between central metabolism of iron as well as dopamine levels and RLS manifestation. A differential diagnosis of RLS includes a wide specter of motor and sensory disorders. Diagnosis is based on clinical features and the history of disease. To correctly diagnose idiopathic RLS one must first eliminate secondary causes of RLS and then also exclude any disorders with clinical features that mimic those of RLS. It has been estimated that some 20 to 25% of patients need pharmacological therapy. Best initial therapy is the application of nonergot dopamine agonists. Anticonvulsants, benzodiazepines and opioides can be given to patients who are refractory to dopaminergic therapy, those suffering from RLS with emphasized painful sensory component and those with RLS connected with insomnia.

  9. Method for collecting thermocouple data via secured shell over a wireless local area network in real time.

    Science.gov (United States)

    Arnold, F; DeMallie, I; Florence, L; Kashinski, D O

    2015-03-01

    This manuscript addresses the design, hardware details, construction, and programming of an apparatus allowing an experimenter to monitor and record high-temperature thermocouple measurements of dynamic systems in real time. The apparatus uses wireless network technology to bridge the gap between a dynamic (moving) sample frame and the static laboratory frame. Our design is a custom solution applied to samples that rotate through large angular displacements where hard-wired and typical slip-ring solutions are not practical because of noise considerations. The apparatus consists of a Raspberry PI mini-Linux computer, an Arduino micro-controller, an Ocean Controls thermocouple multiplexer shield, and k-type thermocouples.

  10. Method for collecting thermocouple data via secured shell over a wireless local area network in real time

    Science.gov (United States)

    Arnold, F.; DeMallie, I.; Florence, L.; Kashinski, D. O.

    2015-03-01

    This manuscript addresses the design, hardware details, construction, and programming of an apparatus allowing an experimenter to monitor and record high-temperature thermocouple measurements of dynamic systems in real time. The apparatus uses wireless network technology to bridge the gap between a dynamic (moving) sample frame and the static laboratory frame. Our design is a custom solution applied to samples that rotate through large angular displacements where hard-wired and typical slip-ring solutions are not practical because of noise considerations. The apparatus consists of a Raspberry PI mini-Linux computer, an Arduino micro-controller, an Ocean Controls thermocouple multiplexer shield, and k-type thermocouples.

  11. Attachment of Free Filament Thermocouples for Temperature Measurements on Ceramic Matrix Composites

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1998-01-01

    At the NASA Lewis Research Center, a new installation technique utilizing convoluted wire thermocouples (TC's) was developed and proven to produce very good adhesion on CMC's, even in a burner rig environment. Because of their unique convoluted design, such TC's of various types and sizes adhere to flat or curved CMC specimens with no sign of delamination, open circuits, or interactions-even after testing in a Mach 0.3 burner rig to 1200 C (2200 F) for several thermal cycles and at several hours at high temperatures. Large differences in thermal expansion between metal thermocouples and low-expansion materials, such as CMC's, normally generate large stresses in the wires. These stresses cause straight wires to detach, but convoluted wires that are bonded with strips of coating allow bending in the unbonded portion to relieve these expansion stresses.

  12. Improving the Quality of Thermocouple Wire Made of Platinum-rhodium Alloys

    Institute of Scientific and Technical Information of China (English)

    HORIKOV P.A.; MAMONOV S.N.; EFIMOV V.N.; RADKIN A.N.; DROZDOV D.E.

    2012-01-01

    For the manufacture of S-type thermocouple the so-called thermocouple wire of platinum and platinum-rhodium alloy is used.One of the main technical requirements for the quality of the wire,according to State Standard of Russia (GOST 10821),is the uniformity of its largest thermoelectric force (Thermo-emf) in the length different sections.It was found that a determining impact on the uniformity of the wire thermo-emf is the distribution of rhodium along the length of the wire.The impact of platinum- rhodium melt crystallization conditions on the inhomogeneity of wire manufactured from it.It was suggested that the chemical inhomogeneity of the wire is related to the liquation phase of platinum-rhodium alloy.

  13. Restless Legs Syndrome and Leg Motor Restlessness in Parkinson's Disease

    Science.gov (United States)

    Miyamoto, Masayuki; Miyamoto, Tomoyuki; Hirata, Koichi

    2015-01-01

    Sleep disturbances are important nonmotor symptoms in Parkinson's disease (PD) that are associated with a negative impact on quality of life. Restless legs syndrome (RLS), which is characterized by an urge to move the legs accompanied by abnormal leg sensations, can coexist with PD, although the pathophysiology of these disorders appears to be different. RLS and PD both respond favorably to dopaminergic treatment, and several investigators have reported a significant relationship between RLS and PD. Sensory symptoms, pain, motor restlessness, akathisia, and the wearing-off phenomenon observed in PD should be differentiated from RLS. RLS in PD may be confounded by chronic dopaminergic treatment; thus, more studies are needed to investigate RLS in drug-naïve patients with PD. Recently, leg motor restlessness (LMR), which is characterized by an urge to move the legs that does not fulfill the diagnostic criteria for RLS, has been reported to be observed more frequently in de novo patients with PD than in age-matched healthy controls, suggesting that LMR may be a part of sensorimotor symptoms intrinsic to PD. In this paper, we provide an overview of RLS, LMR, and PD and of the relationships among these disorders. PMID:26504610

  14. Measurement of the Inhomogeneity in Type B and Land-Jewell Noble-Metal Thermocouples

    Science.gov (United States)

    Webster, E. S.; Greenen, A.; Pearce, J.

    2016-07-01

    Inhomogeneity is the largest contributor to uncertainty in temperature measurements made with thermocouples, and the knowledge of inhomogeneity is essential if low-uncertainty measurements are required. Inhomogeneity is a particular problem for long-term applications at temperatures near or above 1500 ^{circ }hbox {C}, where pairs of alloyed noble-metal thermocouples must be used and the alloy components and potential contaminants become very mobile and cause large deviations in the Seebeck coefficient. While changes in inhomogeneity are a known and well-studied problem in noble-metal alloys at temperatures below 1100 ^{circ }hbox {C}, the effects are not well quantified at higher temperatures. This paper reports the first detailed measurements of inhomogeneity in a number of Type B and Land-Jewell thermocouples exposed to either short-term calibration up to 1600 ^{circ }hbox {C} or long-term in situ measurements for a period of approximately 3000 h at 1600 ^{circ }hbox {C}. The inhomogeneity is measured in a high-resolution scanner operating over the range from 600 ^{circ }hbox {C} to 900 ^{circ }hbox {C}. The results show that drifts of between 0.2 % and 0.6 % can be expected for reversible crystallographic and oxidation effects, whereas drift caused by irreversible contamination effects can be expected to be between 0.6 % and 1.1 %. It is also shown that the deviations in emfs caused by irreversible homogeneities in these thermocouples scale approximately linearly with temperature. This scalability allows uncertainties assessed at one temperature, to be extrapolated to other temperatures. Additionally it is shown that a preconditioning anneal at 1100 ^{circ }hbox {C} should be applied both before and after calibration to remove undesirable crystallographic and rhodium-oxidation effects.

  15. Temperature Measurements Using Type K Thermocouples and the Fluke Helios Plus 2287A Datalogger

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Vonbank, R.; Jensen, Rasmus Lund

    In 1821, the German–Estonian physicist Thomas Johann Seebeck discovered that when any conductor (such as a metal) is subjected to a thermal gradient, it will generate a voltage. This is now known as the thermoelectric effect or Seebeck effect. Any attempt to measure this voltage necessarily invol...... metal combinations. Certain combinations have become popular as industry standards, driven by cost, availability, convenience, melting point, chemical properties, stability, and output. This coupling of two metals gives the thermocouple its name....

  16. Measurement System of Reducing Temperature Fluctuation of Thermostat Bath for Calibrating Thermocouple

    OpenAIRE

    Zhang, Min; Liang, Feixia; Xie, Yue; Huang, Ruguo; Yuan, Haitao; Lu, Jiahua

    2014-01-01

    International audience; Based on the periodic unsteady state heat conduction theory, a new measurement system of reducing temperature fluctuation of thermostat bath was developed in order to obtain a liquid environment with uniform and constant temperature controlled for the measurement requirements of calibrating thermocouple. The experimental results show that the temperature stability in this measurement system is superior to that in traditional system. The measurement system had the advan...

  17. Thermal power output determination of 2 MW heat source by using of thermocouples

    Science.gov (United States)

    Holubcik, Michal; Vician, Peter; Palacka, Matej

    2016-06-01

    Experiment is an operation or procedure carried out under controlled conditions in order to discover an unknown effect or law, to test or establish a hypothesis, or to illustrate a known law. The most important part of the experiment is to evaluate the measured values. Measurement accuracy depends on a number of factors. Deviations of instruments cannot eliminate or influence if it is neglect the possibility of using more precise measuring equipment. Another way for the most accurate results can be calibration. Calibration allows achieve measurement values with relatively high accuracy using less precision instruments. The paper deals about the problematic of thermal power measurement accuracy. Thermal power was measured on heat source with nominal thermal power 2 MW by using direct calorimetric method. There were used ultrasonic flow meter and type K thermocouples. Type K thermocouples are not very suitable for these applications because of their low precision. The paper presents the possibility of using calibrated thermocouples for the thermal power measurement with acceptable accuracy.

  18. A Quantitative Model for the Thermocouple Effect Using Statistical and Quantum Mechanics

    Science.gov (United States)

    Bramley, Paul; Clark, Stewart

    2003-09-01

    This paper employs statistical and quantum mechanics to develop a model for the mechanism underlying the Seebeck effect. The conventional view of the equilibrium criterion for valence electrons in a material is that the Fermi Energy should be constant throughout the system. However, this criterion is an approximation and it is shown to be inadequate for thermocouple systems. An improved equilibrium criterion is developed by applying statistical and quantum mechanics to determine the total flow of electrons across an arbitrary boundary within a system. Dynamic equilibrium is then considered to be the situation where the Fermi Energy either side of the boundary is such that the flow of electrons in each direction is the same. This equilibrium criterion is then applied to the conditions along the thermocouple wires and at the junctions in order to generate a model for the Seebeck effect. The equations involved for calculating the electronic structure of a material cannot be solved analytically, so a solution is achieved using numeric models employing CASTEP code running on a Sun Beowulf cluster and iterative algorithms written in the Excel™ VBA language on a PC. The model is used to calculate the EMF versus temperature function for the gold versus platinum thermocouple, which is then compared with established experimental data.

  19. Relating Composition and Thermoelectric Stability of Pt-Rh Alloy Thermocouples

    Science.gov (United States)

    Pearce, J. V.; Greenen, A. D.; Smith, A.; Elliott, C. J.

    2017-02-01

    A simple model is presented which relates the electromotive force drift rate of Pt-Rh thermoelements to dS/dc, the sensitivity of the Seebeck coefficient, S, to rhodium mass fraction, c. The model has been tested by repeated measurements of a Pt-Rh thermocouple assembly consisting of five thermoelements, using a Co-C high-temperature fixed point (1324°C) for a total duration of 500 h. By considering various thermocouples from the assembly, it is demonstrated that in this case, remarkably, there is a linear relationship between the measured drift rate and the combined dS/dc, where the combination is determined by addition of the individual values for each wire. Particular emphasis is placed on evaluation of the uncertainties associated with the calculations. This result supports previous findings that the thermoelectric stability of Pt-Rh thermoelements improves as the rhodium mass fraction increases. Within this paradigm, it is shown that for a selected Pt-Rh thermoelement of any given composition, there exists a second thermoelement having a composition that yields a minimum drift when combined with the first to form a thermocouple.

  20. Application of Thin-Film Thermocouples to Localized Heat Transfer Measurements

    Science.gov (United States)

    Lepicovsky, J.; Bruckner, R. J.; Smith, F. A.

    1995-01-01

    The paper describes a proof-of-concept experiment on thin-film thermocouples used for localized heat transfer measurements applicable to experiments on hot parts of turbine engines. The paper has three main parts. The first part describes the thin-film sensors and manufacturing procedures. Attention is paid to connections between thin-film thermocouples and lead wires, which has been a source of problems in the past. The second part addresses the test arrangement and facility used for the heat transfer measurements modeling the conditions for upcoming warm turbine tests at NASA LeRC. The paper stresses the advantages of a modular approach to the test rig design. Finally, we present the results of bulk and local heat flow rate measurements, as well as overall heat transfer coefficients obtained from measurements in a narrow passage with an aspect ratio of 11.8. The comparison of bulk and local heat flow rates confirms applicability of thin-film thermocouples to upcoming warm turbine tests.

  1. Restless legs syndrome and periodic leg movements of sleep.

    Science.gov (United States)

    Rye, David B; Trotti, Lynn Marie

    2012-11-01

    Women are more commonly affected than men by restless legs syndrome, and prevalence is highest amongst those of northern European heritage. The motor manifestations include nonvolitional myoclonus (periodic leg movements). Disinhibition of spinal sensorimotor circuits may underlie these primary features and can be affected by peripheral as well as supraspinal networks. Insufficient mobilizable iron stores increase expressivity in some individuals. The sensorimotor features are relieved by dopamine, especially dopamine agonists, gabapentin and its derivatives, and opioids. A diagnosis relies on recognition of key primary and supportive features, and treatments are generally well tolerated, efficacious, and life-changing. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Common cold

    Science.gov (United States)

    ... have a low fever or no fever. Young children often run a fever around 100 to 102°F (37.7 to 38.8°C). Depending on which virus caused your cold, you may also have: Cough Decreased appetite Headache Muscle aches Postnasal drip Sore throat

  3. Project COLD.

    Science.gov (United States)

    Kazanjian, Wendy C.

    1982-01-01

    Describes Project COLD (Climate, Ocean, Land, Discovery) a scientific study of the Polar Regions, a collection of 35 modules used within the framework of existing subjects: oceanography, biology, geology, meterology, geography, social science. Includes a partial list of topics and one activity (geodesic dome) from a module. (Author/SK)

  4. Leg ulcers due to hyperhomocysteinemia

    Directory of Open Access Journals (Sweden)

    Krupa Shankar D

    2006-01-01

    Full Text Available Chronic leg ulcers are rare in young adults and generally indicate a vascular cause. We report a case of a 26-year-old man with leg ulcers of eight months duration. Doppler study indicated venous incompetence and a postphlebitic limb. However, as the distribution and number of ulcers was not consistent with stasis alone and no features of collagen vascular disease were noted, a hyperviscosity state was considered and confirmed with significantly elevated homocysteine level in the serum. Administration of vitamins B1, B2, B6 and B12, trimethyl-glycine, mecobalamine, folic acid and povidone iodine dressings with culture-directed antibiotic therapy led to a satisfactory healing of ulcers over a period of one month. Hyperhomocysteinemia must be considered in the differential diagnosis of leg ulcers in young individuals.

  5. Promethus Hot Leg Piping Concept

    Energy Technology Data Exchange (ETDEWEB)

    AM Girbik; PA Dilorenzo

    2006-01-24

    The Naval Reactors Prime Contractor Team (NRPCT) recommended the development of a gas cooled reactor directly coupled to a Brayton energy conversion system as the Space Nuclear Power Plant (SNPP) for NASA's Project Prometheus. The section of piping between the reactor outlet and turbine inlet, designated as the hot leg piping, required unique design features to allow the use of a nickel superalloy rather than a refractory metal as the pressure boundary. The NRPCT evaluated a variety of hot leg piping concepts for performance relative to SNPP system parameters, manufacturability, material considerations, and comparison to past high temperature gas reactor (HTGR) practice. Manufacturability challenges and the impact of pressure drop and turbine entrance temperature reduction on cycle efficiency were discriminators between the piping concepts. This paper summarizes the NRPCT hot leg piping evaluation, presents the concept recommended, and summarizes developmental issues for the recommended concept.

  6. Cold fusion

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Suk Yong; Sung, Ki Woong; Kang, Joo Sang; Lee, Jong Jik [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-02-01

    So called `cold fusion phenomena` are not confirmed yet. Excess heat generation is very delicate one. Neutron generation is most reliable results, however, the records are erratic and the same results could not be repeated. So there is no reason to exclude the malfunction of testing instruments. The same arguments arise in recording {sup 4}He, {sup 3}He, {sup 3}H, which are not rich in quantity basically. An experiment where plenty of {sup 4}He were recorded is attached in appendix. The problem is that we are trying to search cold fusion which is permitted by nature or not. The famous tunneling effect in quantum mechanics will answer it, however, the most fusion rate is known to be negligible. The focus of this project is on the theme that how to increase that negligible fusion rate. 6 figs, 4 tabs, 1512 refs. (Author).

  7. FAQs on leg ulcer care.

    Science.gov (United States)

    Anderson, Irene; King, Brenda; Knight, Susan; Keynes, Milton

    In a webchat on leg ulcer management issues, hosted by Nursing Times, participants raised three key areas of care: the role of healthcare assistants in compression bandaging; reporting and investigating damage caused by compression therapy; and recommendations for dressings to be used under compression. This article discusses each of these in turn.

  8. Restless Legs Syndrome -- Causes and Symptoms

    Science.gov (United States)

    ... Overview & Facts Causes & Symptoms Self-Tests & Diagnosis Treatment Restless Legs Syndrome - Causes & Symptoms Causes What causes of restless legs syndrome varies from person to person. In some cases ...

  9. Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas.

    Science.gov (United States)

    Farré, R; Montserrat, J M; Rotger, M; Ballester, E; Navajas, D

    1998-01-01

    The aim of this work was to assess the accuracy of thermistors/thermocouples as devices for detecting hypopnoeas in sleep studies. Conventional thermistor/thermocouples were studied with a respiratory model allowing the simulation of inspiratory (22 degrees C) and expiratory (37 degrees C) flows. The thermistor signal (V'th) was compared with a pneumotachograph (V'th): 1) for sinusoidal and square-wave airflows (+/-0.05 to +/-0.8 L.s(-1), 10-20 breaths.min(-1) (bpm)); 2) when changing the distance from the thermistor to the nose (0-20 mm); and 3) when doubling the section of the nostrils. The thermistor was strongly nonlinear and flow reductions (hypopnoeas) were underestimated: a 50% reduction in V' (+/-0.5 L.s(-1), 15 bpm, sinusoidal) resulted in only an 18% reduction in V'th. V'th depended considerably on the airflow pattern: for V'=+/-0.5 L.s(-1), V'th increased by 100% from sinusoidal (20 bpm) to square-wave (10 bpm). For V'=+/-0.5 L.s(-1), 15 bpm, sinusoidal flow, V'th increased by 79% when the distance thermistor-nose varied from 20-0 mm, and V'th decreased by 37% when doubling the nose section. We concluded that thermistor/thermocouples are inaccurate flow-measuring devices when used at the airflow conditions typical of sleep studies. Their use for quantifying hypopnoeas may lead to considerable underdetection of these respiratory events.

  10. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system.

  11. A Multi-channel Pre-processing Circuit for Signals from Thermocouple/Thermister

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this paper,a new developed multi-channel pre-processing circuit for signals from temperature sensor was introduced in brief.This circuit was developed to collect and amplify the signals from temperature sensor.This is a universal circuit.It can be used to process the signals from thermocouples and also used to process signals from thermistors.This circuit was mounted in a standard box(440W×405D×125H mm)as an instrument.The

  12. An Explicit Approach Toward Modeling Thermo-Coupled Deformation Behaviors of SMPs

    Directory of Open Access Journals (Sweden)

    Hao Li

    2017-03-01

    Full Text Available A new elastoplastic J 2 -flow models with thermal effects is proposed toward simulating thermo-coupled finite deformation behaviors of shape memory polymers. In this new model, an elastic potential evolving with development of plastic flow is incorporated to characterize the stress-softening effect at unloading and, moreover, thermo-induced plastic flow is introduced to represent the strain recovery effect at heating. It is shown that any given test data for both effects may be accurately simulated by means of direct and explicit procedures. Numerical examples for model predictions compare well with test data in literature.

  13. The contributions to drift of positive and negative thermoelements in type K MIMS thermocouples

    Science.gov (United States)

    Scervini, M.; Rae, C.

    2013-09-01

    As part of the European project HEATTOP a study on drift of MIMS type K thermocouples above 1000°C has been undertaken: in particular the investigation focused on type K thermoelements of Rescal composition. The approach of this study is based on separating the contributions of each thermoelement to the drift which allows a deeper level of understanding of the contributions of different metallurgical modifications for each thermoelement. At temperature above 1000°C contamination of the thermoelements from the sheath becomes an important factor. The negative thermoelement is particularly prone to drift in MIMS configurations.

  14. [Restless legs syndrome and nocturnal leg pain : Differential diagnosis and treatment].

    Science.gov (United States)

    Hornyak, M; Stiasny-Kolster, K; Evers, S; Happe, S

    2011-09-01

    Pain in the legs belongs to the five most frequent regional pain symptoms. Restless legs syndrome (RLS) presents a particular differential diagnosis for pain in the legs, which is characterized by a nocturnal urge to move the legs often associated with painful sensations in the legs. It is one of the most common neurological disorders and probably the leading cause of nocturnal pain in the legs. In this overview, the diagnosis and therapy of RLS as well as aspects of pain therapy of the disorder are presented. In addition, the differential diagnoses for exclusion of other specific causes of nocturnal pain in the legs are discussed.

  15. Thermocouple Positioning For The Application Of The Non-Integer System Identification Approach To HIFIRE-5 Fins

    Science.gov (United States)

    Lohle, Stefan; Bohrk, Hannah; Fuchs, Ulf

    2011-05-01

    The German Aerospace Center developed a ceramic fin experiment (FinEx) for HIFiRE-5 flight in order to test the performance of new structure designs during hyper- sonic flight. Aero-thermal analysis is provided by 8 thermocouple data channels for all four symmetrically arranged fins. In this paper the analysis of the geometry and thermophysical characteristics of the fins to optimize thermocouple positioning is discussed. The main goal is to gather as much information as possible from these few temperature sensors in these three dimensional structures. Not only is the absolute temperature value of interest but also the reason of the temperature rise. A thorough calculation of the temperature gradients in the fin structure is used to define an optimal positioning layout, where particular focus lies on the localization of the heat fluxes at the surface from the in-depth thermocouple measurement. In conclusion, two fins are equipped with 3 thermocouples each and two are equipped with only 1 thermocouple. The paper closes with some first results based on the calibration data of the fins and the nominal trajectory values.

  16. Restless legs syndrome in multiple system atrophy.

    Science.gov (United States)

    Ghorayeb, Imad; Dupouy, Sandrine; Tison, François; Meissner, Wassilios G

    2014-12-01

    The purpose of the study was to evaluate the frequency of restless legs syndrome in 30 patients with multiple system atrophy. Eight patients complained from restless legs syndrome, their severity score was 19.4 ± 4.1. Pittsburgh Sleep Quality Index scores were significantly higher in patients with restless legs syndrome than those without (9.3 ± 3.7 vs. 4.8 ± 2.9, p = 0.00165). Periodic limb movements were found in 75% of patients with restless legs syndrome. Restless legs syndrome is more prevalent in multiple system atrophy as compared to the acknowledged prevalence in the general population.

  17. Elastic actuation for legged locomotion

    Science.gov (United States)

    Cao, Chongjing; Conn, Andrew

    2017-04-01

    The inherent elasticity of dielectric elastomer actuators (DEAs) gives this technology great potential in energy efficient locomotion applications. In this work, a modular double cone DEA is developed with reduced manufacturing and maintenance time costs. This actuator can lift 45 g of mass (5 times its own weight) while producing a stroke of 10.4 mm (23.6% its height). The contribution of the elastic energy stored in antagonistic DEA membranes to the mechanical work output is experimentally investigated by adding delay into the DEA driving voltage. Increasing the delay time in actuation voltage and hence reducing the duty cycle is found to increase the amount of elastic energy being recovered but an upper limit is also noticed. The DEA is then applied to a three-segment leg that is able to move up and down by 17.9 mm (9% its initial height), which demonstrates the feasibility of utilizing this DEA design in legged locomotion.

  18. 热电偶的选型及误差分析%Thermocouple type selection and error analysis

    Institute of Scientific and Technical Information of China (English)

    张丽

    2012-01-01

      热电偶是工业上常用的温度检测元件,它构造简单、测量范围广、精度高。在实际使用中,若热电偶选型错误,或者测量时操作不当,均会导致测量数据失真。主要介绍了热电偶的正确选择、使用及解决误差的办法。%  thermocouple is common industrial temperature detection device, it has the advantages of simple structure, wide measuring range, high precision. In actual use, if the thermocouple type errors, or when measuring the improper operation, will lead to the distortion of measurement data. Mainly introduces the correct selection of the use of thermocouple, and the solution error approach.

  19. Development and Testing of Tungsten-rhenium Thermocouples%钨铼热电偶开发与测试

    Institute of Scientific and Technical Information of China (English)

    王彦明; 郝彦军

    2012-01-01

    近年来随着钨铼丝测温精度的不断提高,并因其廉价性,钨铼型快速热电偶将逐渐替代铂铑型快速热电偶。介绍钨铼热电偶开发与测试过程中的一些要点。%In recent years, with the continuous improvement of the tungsten-rhenium wire temperature measurement accuracy, and its cheap, fast tungsten-rhenium thermocouples will gradually replace the platinum and rhodium fast thermocouple. This article describes some of the key points in the tungsten-rhenium thermocouples development and testing process.

  20. A fine-wire thermocouple probe for measurement of stagnation temperatures in real gas hypersonic flows of nitrogen

    Science.gov (United States)

    Hollis, Brian R.; Griffith, Wayland C.; Yanta, William J.

    1991-01-01

    A fine-wire thermocouple probe was used to determine freestream stagnation temperatures in hypersonic flows. Data were gathered in a N2 blowdown wind tunnel with runtimes of 1-5 s. Tests were made at supply pressures between 30 and 1400 atm and supply temperatures between 700 and 1900 K, with Mach numbers of 14 to 16. An iterative procedure requiring thermocouple data, pilot pressure measurements, and supply conditions was used to determine test cell stagnation temperatures. Probe conduction and radiation losses, as well as real gas behavior of N2, were accounted for during analysis. Temperature measurement error was found to be 5 to 10 percent. A correlation was drawn between thermocouple diameter Reynolds number and temperature recovery ratio. Transient probe behavior was studied and was found to be adequate in temperature gradients up to 1000 K/s.

  1. Study of improving working life of thermocouple%提高热电偶使用寿命的研究

    Institute of Scientific and Technical Information of China (English)

    李丽

    2016-01-01

    This paper introduces the Thermocouples used in blast furnace hot blast stove to mix the wind temperature detection damage failure analysis,and How to improve the service life of the mixed wind temperature detection with thermocouple.%本文着重介绍了高炉热风炉混风温度检测用热电偶损坏故障分析以及如何提高混风温度检测用热电偶的使用寿命.

  2. 设计师访谈:Three Legged Legs

    Institute of Scientific and Technical Information of China (English)

    JOE; RUSS

    2007-01-01

    Greg Gunn、Casey Hunt和Reza Rasoli,又称Three Legged Legs。于2006年获得了全球学生动画奖(Global Student Animation Award)。现在他们又带回了一个精彩的新短片《Samurai》。我们自然也不会放过这次机会,看看能不能了解到更多内幕信息。

  3. Cough & Cold Medicine Abuse

    Science.gov (United States)

    ... A Week of Healthy Breakfasts Shyness Cough & Cold Medicine Abuse KidsHealth > For Teens > Cough & Cold Medicine Abuse ... DXM Why Do People Use Cough and Cold Medicines to Get High? There's an ingredient in many ...

  4. Epilepsy and restless legs syndrome.

    Science.gov (United States)

    Geyer, James D; Geyer, Emery E; Fetterman, Zachary; Carney, Paul R

    2017-03-01

    Restless legs syndrome (RLS) is a common neurological movement disorder occurring in approximately 10% of the general population. The prevalence of moderately severe RLS is 2.7% overall (3.7% for women and 1.7% for men). Epilepsy is also a common neurological disorder with significant associated morbidity and impact on quality of life. We evaluated the severity and frequency of primary RLS in patients with localization-related temporal lobe epilepsy (TLE) and investigated the role of prodromal RLS symptoms as a warning sign and lateralizing indicator. All epilepsy patients seen in the outpatient clinic were screened for movement disorders from 2005 to 2015. Ninety-eight consecutive patients with localization-related TLE (50 right TLE and 48 left TLE) who met inclusion criteria were seen in the outpatient clinic. The control group consisted of 50 individuals with no history or immediate family history of epilepsy. Each patient was evaluated with the International Restless Legs Study Group (IRLSSG) questionnaire, NIH RLS diagnostic criteria, ferritin level, and comprehensive sleep screening including polysomnography. Furthermore, patients with obstructive sleep apnea or a definite cause of secondary restless legs syndrome such as low serum ferritin or serum iron levels were also excluded from the study. There was a significant association between the type of epilepsy and whether or not patients had RLS χ(2) (1)=10.17, prestlessness was typically described as moderately severe. The RLS symptoms were more common and somewhat more severe in the right TLE group than the left TLE group. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. [Epidemiology of restless legs syndrome].

    Science.gov (United States)

    Ghorayeb, I; Tison, F

    2009-01-01

    Restless legs syndrome (RLS) is a chronic sensorimotor disorder where patients complain of an almost irresistible urge to move their legs. This urge can often be accompanied by pain or other unpleasant sensations, it either occurs or worsens with rest particularly at night, and improves with activity. The International Restless Legs Syndrome Study Group has established four essential criteria for clinical diagnosis of RLS. Affecting an estimated 7.2 to 11.5% of the adult population, the symptoms of RLS may be associated with significant sleep disturbance and may have a negative impact on quality of life. The prevalence of RLS increases with age, and women are more frequently affected than men. In France, the estimated prevalence is 8.5%. Among sufferers, 4.4% complain of very severe symptoms. Although RLS is mainly idiopathic, several clinical conditions have been associated with it, especially iron deficiency with or without anemia, end-stage renal disease and pregnancy. These conditions may share a common pathophysiological mechanism involving a disorder of iron metabolism. By contrast, controversy persists as to whether polyneuropathy, particularly when associated with diabetes, is to be considered as an important cause of secondary RLS. This association is difficult to demonstrate as conventional electromyography is not adequate to detect small fiber neuropathy often associated with diabetes. RLS is often underdiagnosed and few subjects receive recommended RLS drug treatment. There is a clear need for complementary education to improve the accurate diagnosis of RLS. Indeed, better knowledge of this syndrome is a prerequisite to prompt an appropriate therapeutic management.

  6. Neuroimaging in Restless Legs Syndrome.

    Science.gov (United States)

    Provini, Federica; Chiaro, Giacomo

    2015-09-01

    Neuroimaging studies are of crucial relevance in defining the pathophysiology of restless legs syndrome (RLS). MRI studies showed no structural brain lesions and confirmed a central iron deficiency. Structural and functional studies showed an involvement of the thalamus, sensorimotor cortical areas, and cerebellum in RLS and assessed neurotransmission abnormalities in the dopaminergic and opiate systems. Finally, glutamatergic hyperactivity has been proposed as a cause of disrupted and shortened sleep in RLS. Differences among the results of the studies make it difficult to draw any definitive conclusions, thus, suggesting the need for future research.

  7. Novel assessment of microvascular changes in idiopathic restless legs syndrome (Willis-Ekbom disease).

    Science.gov (United States)

    Anderson, Kirstie N; Di Maria, Costanzo; Allen, John

    2013-06-01

    Many patients with restless legs syndrome (Willis-Ekbom disease) complain of burning sensations in their feet associated with the desire to move, such that they seek cooler environments. This pilot study aimed to characterise the microvascular skin changes in 12 patients with restless legs syndrome compared with 12 age- and sex-matched controls. Patients with moderate or severe restless legs syndrome and controls underwent detailed thermovascular assessment in a controlled temperature room at three different stages (normothermic phase 23 °C, hot phase 30 °C, cold phase 18 °C). Microvascular activity was recorded during all phases by bilateral great toe laser-Doppler flowmetry and also by whole-body thermography. Patient and control measurements were compared. The study protocol was well tolerated. Parameters extracted from the laser-Doppler flowmetry measurements were used to model a logistic function using binary logistic regression. This demonstrated a statistically significant difference between patients with restless legs syndrome and healthy controls (P restless legs syndrome patients compared with controls. Thermography analysis also showed significant differences between foot temperatures in patients with restless legs syndrome compared with controls during the hot phase (P = 0.011). Notably, patients with restless legs syndrome had more uniform foot temperatures, whereas controls had a wider variability in surface temperature across the feet. This novel study demonstrates impaired microvascular circulation in patients with restless legs syndrome in comparison to matched controls and a potential mechanism for the sensation of burning feet. The protocol also provides an experimental paradigm to test therapeutic interventions for the future. © 2013 European Sleep Research Society.

  8. Chronic measurement of cardiac output in unanesthetized rats using miniature thermocouples.

    Science.gov (United States)

    Osborn, J W; Barber, B J; Quillen, E W; Abram, R J; Cowley, A W

    1986-12-01

    A thermodilution technique is described for measuring steady-state cardiac output (CO) in conscious rats for periods of 2-3 wk. The method utilizes small implantable aortic thermocouples inserted via the femoral artery at the time of placement of other chronic indwelling catheters. Data are presented to validate the accuracy and reproducibility of the technique by acute in situ comparison with electromagnetic flowmeter measurements. Responses in chronically instrumented rats were tested with hemorrhage and infusions of vasodilator and vasoconstrictor agents administered repeatedly over a period of 9 days. The results show that the system is capable of measuring CO chronically and provides reproducible responses for periods of at least several weeks. We conclude that these methods provide a single, inexpensive, and accurate way to measure steady-state CO in conscious, unrestrained rats.

  9. Tile Surface Thermocouple Measurement Challenges from the Orbiter Boundary Layer Transition Flight Experiment

    Science.gov (United States)

    Campbell, Charles H.; Berger, Karen; Anderson, Brian

    2012-01-01

    Hypersonic entry flight testing motivated by efforts seeking to characterize boundary layer transition on the Space Shuttle Orbiters have identified challenges in our ability to acquire high quality quantitative surface temperature measurements versus time. Five missions near the end of the Space Shuttle Program implemented a tile surface protuberance as a boundary layer trip together with tile surface thermocouples to capture temperature measurements during entry. Similar engineering implementations of these measurements on Discovery and Endeavor demonstrated unexpected measurement voltage response during the high heating portion of the entry trajectory. An assessment has been performed to characterize possible causes of the issues experienced during STS-119, STS-128, STS-131, STS-133 and STS-134 as well as similar issues encountered during other orbiter entries.

  10. High temperature thermocouple and heat flux gauge using a unique thin film-hardware hot juncture

    Science.gov (United States)

    Liebert, C. H.; Holanda, R.; Hippensteele, S. A.; Andracchio, C. A.

    1984-01-01

    A special thin film-hardware material thermocouple (TC) and heat flux gauge concept for a reasonably high temperature and high flux flat plate heat transfer experiment was fabricated and tested to gauge temperatures of 911 K. This concept was developed for minimal disturbance of boundary layer temperature and flow over the plates and minimal disturbance of heat flux through the plates. Comparison of special heat flux gauge Stanton number output at steady-state conditions with benchmark literature data was good and agreement was within a calculated uncertainty of the measurement system. Also, good agreement of special TC and standard TC outputs was obtained and the results are encouraging. Oxidation of thin film thermoelements was a primary failure mode after about 5 of operation.

  11. Simple method for measuring vibration amplitude of high power airborne ultrasonic transducer: using thermo-couple.

    Science.gov (United States)

    Saffar, Saber; Abdullah, Amir

    2014-03-01

    Vibration amplitude of transducer's elements is the influential parameters in the performance of high power airborne ultrasonic transducers to control the optimum vibration without material yielding. The vibration amplitude of elements of provided high power airborne transducer was determined by measuring temperature of the provided high power airborne transducer transducer's elements. The results showed that simple thermocouples can be used both to measure the vibration amplitude of transducer's element and an indicator to power transmission to the air. To verify our approach, the power transmission to the air has been investigated by other common method experimentally. The experimental results displayed good agreement with presented approach. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Peltier effect exchanges in contact thermocouples - Application to the characterization of new thermoelectric circuits

    Science.gov (United States)

    Berrached, N.-E.

    Results from an investigation of coupling in thermoelectric circuits manufactured by electrodeposition of a metallic conductor on a conducting foil made of a different material are presented. The study was undertaken to define the significant factors in the design and manufacture of thermal fluxmeters. Theoretical considerations indicate that the voltage appearing between output connections is proportional to the average spatial thermal gradient on the sensitive surface of the thermoelement. A figure of merit is defined for the coupling of the contact thermocouples. Localized thermal exchanges of opposite sign are shown to occur due to the passage of current, and are concentrated at the boundaries of each thermoelement. Nonisothermal tangential thermal gradients appear on the surface of the circuit. Experimental studies confirm the appearance of the gradients by their IR signatures. Finally, the gradients are determined to be affected by the thickness and conductivity of the medium placed between the emitter and detector circuits.

  13. Sympathetic adaptations to one-legged training

    Science.gov (United States)

    Ray, C. A.

    1999-01-01

    The purpose of the present study was to determine the effect of leg exercise training on sympathetic nerve responses at rest and during dynamic exercise. Six men were trained by using high-intensity interval and prolonged continuous one-legged cycling 4 day/wk, 40 min/day, for 6 wk. Heart rate, mean arterial pressure (MAP), and muscle sympathetic nerve activity (MSNA; peroneal nerve) were measured during 3 min of upright dynamic one-legged knee extensions at 40 W before and after training. After training, peak oxygen uptake in the trained leg increased 19 +/- 2% (P leg exercise and indicates that attenuation of MSNA to exercise reported with forearm training also occurs with leg training.

  14. Cold confusion

    Energy Technology Data Exchange (ETDEWEB)

    Chapline, G.

    1989-07-01

    On March 23 two chemists, Martin Fleischmann and Stanley Pons startled the world with a press conference at the University of Utah where they announced that they had achieved nuclear fusion at room temperatures. As evidence they cited the production of ''excess'' amounts of heat in an electrochemical apparatus and observation of neutron production. While the production of heat in a chemical apparatus is not in itself unusual the observation of neutrons is certainly extraordinary. As it turned out, though, careful measurements of the neutron production in electrochemical apparatus similar to that used by Fleischmann and Pons carried out at dozens of other laboratories has shown that the neutron production fails by many orders of magnitude to support the assertion by Fleischmann and Pons that their discovery represents a new and cheap source of fusion power. In particular, independent measurements of the neutron production rate suggest that the actual rate of fusion energy production probably does not exceed 1 trillionth of a watt. This paper discusses the feasibility that cold fusion is actually being achieved. 7 refs.

  15. Mount Everest and Makalu cold injury amputation: 40 years on.

    Science.gov (United States)

    Morrison, Shawnda A; Gorjanc, Jurij; Mekjavic, Igor B

    2014-04-01

    Freezing cold injuries (frostbite) of the extremities are a common injury among alpinists participating in high altitude expeditions, particularly during inclement weather conditions. Anecdotally, a digit that has suffered frostbite may be at greater risk to future cold injuries. In this case study, we profile a 62-year-old elite alpinist who suffered multiple digit amputations on both his hands and foot after historic summit attempts on Makalu (8481 m) and Mt. Everest (8848 m) in 1974-1979. We describe the clinical treatment he received at that time, and follow up his case 40 years after the first incidence of frostbite utilizing a noninvasive evaluation of hand and foot function to a cold stress test, including rates of re-warming to both injured and non-injured digits. Finger rates of recovery to the cold stress test were not different (0.8 vs. 1.0°C·min(-1)) except one (injured, left middle finger, distal phalanx; 0.4°C·min(-1)). Toe recovery rates after cold-water immersion were identical between previously injured and non-injured toes (0.2°C·min(-1)). Thermocouple data indicate that this alpinist's previous frostbite injuries may not have significantly altered his digit rates of re-warming during passive recovery compared to his non-injured digits.

  16. Investigation of the viscous heating artefact arising from the use of thermocouples in a focused ultrasound field.

    Science.gov (United States)

    Morris, Hugh; Rivens, Ian; Shaw, Adam; Haar, Gail Ter

    2008-09-07

    Accurate temperature measurements in therapeutic ultrasound fields are necessary for understanding damage mechanisms, verification of thermal modelling and calibration of non-invasive clinical thermometry. However, artefactual heating, primarily due to viscous forces which result from motion relative to the surrounding tissue, occurs when metal thermocouples are used in an ultrasound field. The magnitude and time dependence of this artefact has been characterized by comparison with novel thin-film thermocouples (TFTs) at 1-2 cm focal depths in fresh degassed ex vivo bovine liver. High-intensity focused ultrasound exposures (1.7 MHz; free-field spatial-peak temporal-average intensities 40-600 W cm(-2)) were used. Subtraction of the TFT data from that obtained for other thermocouples yielded the time dependence of the viscous heating artefact. This was found to be intensity independent up to 600 W cm(-2) (below the threshold for cavitation and lesion formation) and remained significant at radial distances out to the first side lobe in the focal plane. The contribution of viscous heating to cooling was also found to be significant for at least 5 s after the end of insonation. The ratio of viscous artefact to absorptive heating after 5 s was: 1.76 +/- 0.07 for a fine-wire, 0.45 +/- 0.07 and 1.93 +/- 0.07 for two different sheathed-wires and 0.24 +/- 0.07 for a needle thermocouple.

  17. Distortion of millimeter-wave absorption in biological media due to presence of thermocouples and other objects.

    Science.gov (United States)

    Alekseev, S I; Ziskin, M C

    2001-09-01

    Specific absorption rate (SAR) distributions in the vicinity of a thermocouple or air bubble in water and in the presence of hair or sweat duct in skin were calculated using analytical and two-dimensional impedance methods. The objects were exposed to uniform 42.25 GHz plane electromagnetic fields. Insertion of a 0.1-mm thermocouple or similarly sized air bubble into water produced a strong localized disturbance of the otherwise uniform SAR distribution. However, the average of SAR values immediately surrounding the thermocouple was close to the undisturbed uniform average SAR. This allows measuring the average SAR during exposure of both unbounded and bounded media using calibrated small thermocouples (up to 0.1 mm). The SAR distribution in the vicinity of a hair was qualitatively similar to that produced by an air bubble. The maximal value of SAR was more than three times higher than the overall average SAR value in the skin. Sweat ducts produced a smaller disturbance of the millimeter-wave (mm-wave) field.

  18. Restless legs syndrome and periodic leg movements in patients with movement disorders: Specific considerations.

    Science.gov (United States)

    Högl, Birgit; Stefani, Ambra

    2017-05-01

    Restless legs syndrome is a frequent neurological disorder with potentially serious and highly distressing treatment complications. The role and potential implications of periodic leg movements during sleep range from being a genetic risk marker for restless legs syndrome to being a cardiovascular risk factor. The diagnosis of restless legs syndrome in patients with daytime movement disorders is challenging and restless legs syndrome needs to be differentiated from other sleep-related movement disorders. This article provides an update on the diagnosis of restless legs syndrome as an independent disorder and the role of periodic leg movements and reviews the association of restless legs syndrome with Parkinson's disease and other movement disorders. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  19. Treatment of restless legs syndrome.

    Science.gov (United States)

    Comella, Cynthia L

    2014-01-01

    Restless legs syndrome (RLS) is a common disorder diagnosed by the clinical characteristics of restlessness in the legs associated often with abnormal sensations that start at rest and are improved by activity, occurring with a diurnal pattern of worsened symptoms at night and improvement in the morning. RLS is the cause of impaired quality of life in those more severely afflicted. Treatment of RLS has undergone considerable change over the last few years. Several classes of medications have demonstrated efficacy, including the dopaminergic agents and the alpha-2-delta ligands. Levodopa was the first dopaminergic agent found to be successful. However, chronic use of levodopa is frequently associated with augmentation that is defined as an earlier occurrence of symptoms frequently associated with worsening severity and sometimes spread to other body areas. The direct dopamine agonists, including ropinirole, pramipexole, and rotigotine patch, are also effective, although side effects, including daytime sleepiness, impulse control disorders, and augmentation, may limit usefulness. The alpha-2-delta ligands, including gabapentin, gabapentin enacarbil, and pregabalin, are effective for RLS without known occurrence of augmentation or impulse control disorders, although sedation and dizziness can occur. Other agents, including the opioids and clonazepam do not have sufficient evidence to recommend them as treatment for RLS, although in an individual patient, they may provide benefit.

  20. Targinact for restless legs syndrome.

    Science.gov (United States)

    2016-04-01

    Idiopathic restless legs syndrome (RLS)--also known as Willis-Ekbom disease--is a neurological condition characterised by an overwhelming urge to move the legs, occurring during rest or inactivity, especially at night. Symptoms are highly variable in frequency and severity, and can affect sleep and quality of life. First-line management includes addressing precipitating or aggravating factors and providing explanation, reassurance and advice on self-help strategies. Drug therapy (e.g. a dopamine agonist) is used for patients with more severe symptoms. In December 2014, the marketing authorisation for a modified-release preparation containing oxycodone and naloxone (Targinact-Napp Pharmaceuticals) was expanded to include use in the treatment of severe to very severe RLS after failure of dopaminergic therapy.(10)Here we review the management of adults with RLS, including the place of oxycodone/naloxone. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Cold energy

    Science.gov (United States)

    Wallace, John P.

    2015-12-01

    Deviations in Q for resonant superconducting radio frequency niobium accelerator cavities are generally correlated with resistivity loss mechanisms. Field dependent Qs are not well modeled by these classical loss mechanisms, but rather can represent a form of precision cavity surface thermometry. When the field dependent Q variation shows improvement with increasing B field level the classical treatment of this problem is inadequate. To justify this behavior hydrogen as a ubiquitous impurity in niobium, which creates measurable property changes, even at very low concentrations is typically considered the cause of such anomalous behavior. This maybe the case in some instances, but more importantly any system operating with a highly coherent field with a significant time dependent magnetic component at near 2° K will have the ability to organize the remaining free spins within the London penetration depth to form a coupled energy reservoir in the form of low mass spin waves. The niobium resonant cavities are composed of a single isotope with a large nuclear spin. When the other loss mechanisms are stripped away this may be the gain medium activated by the low level residual magnetic fields. It was found that one resonant cavity heat treatment produced optimum surface properties and then functioned as a MASER extracting energy from the 2° K thermal bath while cooling the cavity walls. The cavity operating in this mode is a simulator of what can take place in the wider but not colder universe using the cosmic microwave background (CMB) as a thermal source. The low mass, long lifetimes, and the scale of the magnetic spin waves on the weakly magnetized interstellar medium allows energy to be stored that is many orders of magnitude colder than the cosmic microwave background. A linear accelerator cavity becomes a tool to explore the properties of the long wave length magnetic spin waves that populate this cold low energy regime.

  2. Cold energy

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, John P., E-mail: jpw@castinganalysis.com [Casting Analysis Corp., PO Box 52, Weyers Cave, VA 24486 (United States)

    2015-12-04

    Deviations in Q for resonant superconducting radio frequency niobium accelerator cavities are generally correlated with resistivity loss mechanisms. Field dependent Qs are not well modeled by these classical loss mechanisms, but rather can represent a form of precision cavity surface thermometry. When the field dependent Q variation shows improvement with increasing B field level the classical treatment of this problem is inadequate. To justify this behavior hydrogen as a ubiquitous impurity in niobium, which creates measurable property changes, even at very low concentrations is typically considered the cause of such anomalous behavior. This maybe the case in some instances, but more importantly any system operating with a highly coherent field with a significant time dependent magnetic component at near 2° K will have the ability to organize the remaining free spins within the London penetration depth to form a coupled energy reservoir in the form of low mass spin waves. The niobium resonant cavities are composed of a single isotope with a large nuclear spin. When the other loss mechanisms are stripped away this may be the gain medium activated by the low level residual magnetic fields. It was found that one resonant cavity heat treatment produced optimum surface properties and then functioned as a MASER extracting energy from the 2° K thermal bath while cooling the cavity walls. The cavity operating in this mode is a simulator of what can take place in the wider but not colder universe using the cosmic microwave background (CMB) as a thermal source. The low mass, long lifetimes, and the scale of the magnetic spin waves on the weakly magnetized interstellar medium allows energy to be stored that is many orders of magnitude colder than the cosmic microwave background. A linear accelerator cavity becomes a tool to explore the properties of the long wave length magnetic spin waves that populate this cold low energy regime.

  3. Restless legs syndrome mimicking S1 radiculopathy.

    Science.gov (United States)

    Zambelis, Th; Wolgamuth, B R; Papoutsi, S N; Economou, N T

    2016-01-01

    Α case of a chronic idiopathic form of a severe type of Restless Legs Syndrome (RLS), which developed during pregnancy and persisted after this, misdiagnosed for 34 years as radiculopathy S1, is reported. In spite of the thorough clinical and laboratory investigation, in addition to constant changes of the therapeutic approach, the diagnosis of S1 radiculopathy could not be confirmed, resulting in a chronic clinical course; the latter was characterized by relapses and remissions not attributed or linked in any way to the treatment (various types of). In fact, it was due to a routine workup in a sleep clinic, where the patient was referred because of a coincident chronic insomnia (Restless Legs Syndrome is a known and important cause of insomnia/chronic insomnia), which resulted in a proper diagnosis and treatment of this case. With the use of Restless Legs Syndrome appropriate treatment (Pramipexole 0.18 mg taken at bedtime, a dopaminergic agent and Level A recommended drug for Restless Legs Syndrome) an excellent response and immediate elimination of symptoms was achieved. Restless Legs Syndrome may present with a variety of symptoms (with the most prominent shortly being reported with the acronym URGE: Urge to move the legs usually associated with unpleasant leg sensations, Rest induces symptoms, Getting active brings relief, Evening and night deteriorate symptoms); given the fact that Restless Legs Syndrome presents with a great variety and heterogeneity of symptoms (mostly pain, dysesthesia and paresthesia), which may occur in several other diseases (the so called "RLS mimics"), proper diagnosis of Restless Legs Syndrome usually fails. Restless Legs Syndrome misinterpreted as S1 radiculopathy, to the best of our knowledge, has not been reported yet in the literature. Here, case history, clinical course and common RLS mimics are presented. Different forms of Restless Legs Syndrome manifestations, which are commonly -as in this case- misinterpreted due to their

  4. Why do flamingos stand on one leg?

    Science.gov (United States)

    Anderson, Matthew J; Williams, Sarah A

    2010-01-01

    A series of observational studies of captive Caribbean flamingos Phoenicopterus ruber were conducted to determine why flamingos rest on one leg. While frequently asked by the general public, this basic question has remained unanswered by the scientific community. Here we suggest that the latency of flamingos to initiate forward locomotion following resting on one leg is significantly longer than following resting on two, discounting the possibility that unipedal resting reduces muscle fatigue or enhances predatory escape. Additionally, we demonstrate that flamingos do not display lateral preferences at the individual or group levels when resting on one leg, with each bird dividing its resting time across both legs. We show that while flamingos prefer resting on one leg to two regardless of location, the percentage of birds resting on one leg is significantly higher among birds standing in the water than among those on land. Finally, we demonstrate a negative relationship between temperature and the percentage of observed birds resting on one leg, such that resting on one leg decreases as temperature rises. Results strongly suggest that unipedal resting aids flamingos in thermoregulation. (c) 2009 Wiley-Liss, Inc.

  5. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Femur (Upper Leg) KidsHealth > For Parents > X-Ray Exam: Femur (Upper Leg) A A A ... español Radiografía: fémur What It Is A femur X-ray is a safe and painless test that ...

  6. Ropinirole treatment for restless legs syndrome.

    Science.gov (United States)

    Molnar, Miklos Zsolt; Fornadi, Katalin; Shapiro, Colin M

    2006-09-01

    In this paper we discuss therapy with ropinirole (known as adartrel in the United Kingdom) in patients with restless legs syndrome. Restless legs syndrome is characterized by an urge to move the legs, uncomfortable sensations in the legs and worsening of these symptoms during rest with at least temporary relief brought on by activity. Current recommendations suggest dopaminergic therapy (levodopa or dopamine receptor agonists like ropinirole) as the first-line treatment for restless legs syndrome. Based on the results of randomized, placebo-controlled, double-blind trials, we conclude that ropinirole is effective in reducing symptoms of restless legs syndrome in the general population. Ropinirole has no serious or common side effects that would limit its use significantly. Rebound and augmentation problems are relatively rarely seen with ropinirole, although properly designed comparative trials are still needed to address this question. It must be noted, however, that most published studies with ropinirole compare this drug with placebo. Very few studies have compared ropinirole with other drugs (L-dopa, gabapentin, opioids, benzodiazepines, other dopaminergic agents and selegiline hydrochloride). No cost-effectiveness trial has been published yet. Treatment of restless legs syndrome with ropinirole shows it to be effective, well-tolerated and safe and it can be used in restless legs syndrome in general.

  7. Diagnosis and treatment of restless legs syndrome.

    Science.gov (United States)

    Sales, Samantha; Sanghera, Manjit K; Klocko, David J; Stewart, R Malcolm

    2016-07-01

    Restless legs syndrome (RLS) is a disorder characterized by an irresistible urge to move the legs during rest, usually accompanied by uncomfortable sensations in the affected extremity or extremities. RLS can manifest at any age but prevalence increases with advancing age. This article describes the symptoms of RLS, associated comorbidities, and how to diagnose and manage RLS.

  8. Update in restless legs syndrome

    Science.gov (United States)

    Salas, Rachel E.; Gamaldo, Charlene E.; Allen, Richard P.

    2016-01-01

    Purpose of review Although restless legs syndrome (RLS) is a disorder recognized in the medical literature since the 17th century, there have only recently been significant clinical and scientific advances in diagnosis, epidemiology and understanding the disorder, mainly due to the advent of dopaminergic treatment. Recent findings Recent discoveries have uncovered the iron–dopamine connection in RLS and the basic dopaminergic pathology related to the RLS symptoms. These have led to new understanding of the morbidity of RLS and the many conditions associated with RLS, which have also supported new approaches to treatment. These developments are each briefly described here. Summary Although there has been progress in understanding, diagnosing and treating RLS, it remains an underdiagnosed and undertreated condition severely impairing functioning of patients with moderate-to-severe disease. Much work is needed to improve on current, as well as other novel therapies. PMID:20581683

  9. Opioids for restless legs syndrome.

    Science.gov (United States)

    de Oliveira, César Osório; Carvalho, Luciane Bc; Carlos, Karla; Conti, Cristiane; de Oliveira, Marcio M; Prado, Lucila Bf; Prado, Gilmar F

    2016-06-29

    Restless legs syndrome (RLS) is a distressing and common neurological disorder that may have a huge impact in the quality of life of those with frequent and intense symptoms. Patients complain of unpleasant sensations in the legs, at or before bedtime, and feel an urge to move the legs, which improves with movement, such as walking. Symptoms start with the patient at rest (e.g. sitting or lying down), and follow a circadian pattern, increasing during the evening or at night. Many pharmacological intervention are available for RLS, including drugs used to treat Parkinson's disease (L-Dopa and dopaminergic agonists), epilepsy (anticonvulsants), anxiety (benzodiazepines), and pain (opioids). Dopaminergic drugs are those most frequently used for treatment of RLS, but some patients do not respond effectively and require other medication. Opioids, a class of medications used to treat severe pain, seem to be effective in treating RLS symptoms, and are recommended for patients with severe symptoms, because RLS and pain appear to share the same mechanism in the central nervous system. All available drugs are associated to some degree with side effects, which can impede treatment. Opioids are associated with adverse events such as constipation, tolerance, and dependence. This justifies the conduct of a systematic review to ascertain whether opioids are safe and effective for treatment of RLS. To asses the effects of opioids compared to placebo treatment for restless legs syndrome in adults. We searched the Cochrane Central Register of Controlled trials, CENTRAL 2016, issue 4 and MEDLINE, EMBASE, and LILACS up to April 2016, using a search strategy adapted by Cochraneto identify randomised clinical trials. We checked the references of each study and established personal communication with other authors to identify any additional studies. We considered publications in all languages. Randomised controlled clinical trials of opioid treatment in adults with idiopathic RLS. Two

  10. Intensive treatment of leg lymphedema

    Directory of Open Access Journals (Sweden)

    Pereira de Godoy Jose

    2010-01-01

    Full Text Available Background: Despite of all the problems caused by lymphedema, this disease continues to affect millions of people worldwide. Thus, the identification of the most efficacious forms of treatment is necessary. Aim: The aim of this study was to evaluate a novel intensive outpatient treatment for leg lymphedema. Methods: Twenty-three legs of 19 patients were evaluated in a prospective randomized study. The inclusion criteria were patients with Grade II and III lymphedema, where the difference, measured by volumetry, between the affected limb below the knee and the healthy limb was greater than 1.5 kg. Intensive treatment was carried out for 6- to 8-h sessions in the outpatient clinic. Analysis of variance was utilized for statistical analysis with an alpha error of 5% (P-value < 0.05 being considered significant. Results: All limbs had significant reductions in size with the final mean loss being 81.1% of the volume of edema. The greatest losses occurred in the first week (P-value < 0.001. Losses of more than 90% of the lymphedema occurred in 9 (39.13% patients; losses of more than 80% in 13 (56.52%, losses of more than 70% in 17 (73.91% and losses of more than 50% were recorded for 95.65% of the patients; only 1 patient lost less than 50% (37.9% of the edema. Conclusion: The intensive treatment of lymphedema in the outpatient clinic can produce significant reductions in the volume of edema over a short period of time and can be recommended for any grade of lymphedema, in particular the more advanced degrees.

  11. Neurobiology: reconstructing the neural control of leg coordination.

    Science.gov (United States)

    Zill, Sasha N; Keller, Bridget R

    2009-05-12

    Walking is adaptable because the timing of movements of individual legs can be varied while maintaining leg coordination. Recent work in stick insects shows that leg coordination set by interactions of pattern generating circuits can be overridden by sensory feedback.

  12. Steerable Hopping Six-Legged Robot

    Science.gov (United States)

    Younse, Paulo; Aghazarian, Hrand

    2010-01-01

    The figure depicts selected aspects of a six-legged robot that moves by hopping and that can be steered in the sense that it can be launched into a hop in a controllable direction. This is a prototype of hopping robots being developed for use in scientific exploration of rough terrain on remote planets that have surface gravitation less than that of Earth. Hopping robots could also be used on Earth, albeit at diminished hopping distances associated with the greater Earth gravitation. The upper end of each leg is connected through two universal joints to an upper and a lower hexagonal frame, such that the tilt of the leg depends on the relative position of the two frames. Two non-back-driveable worm-gear motor drives are used to control the relative position of the two frames along two axes 120 apart, thereby controlling the common tilt of all six legs and thereby, further, controlling the direction of hopping. Each leg includes an upper and a lower aluminum frame segment with a joint between them. A fiberglass spring, connected via hinges to both segments, is used to store hopping energy prior to launch into a hop and to cushion the landing at the end of the hop. A cable for loading the spring is run into each leg through the center of the universal joints and then down along the center lines of the segments to the lower end of the leg. A central spool actuated by a motor with a harmonic drive and an electromagnetic clutch winds in all six cables to compress all six springs (thereby also flexing all six legs) simultaneously. To ensure that all the legs push off and land in the same direction, timing- belt pulley drives are attached to the leg segments, restricting the flexing and extension of all six legs to a common linear motion. In preparation for a hop, the spool can be driven to load the spring legs by an amount corresponding to a desired hop distance within range. The amount of compression can be computed from the reading of a shaft-angle encoder that

  13. Practical system for the direct measurement of magneto-caloric effect by micro-thermocouples.

    Science.gov (United States)

    Kamarád, J; Kaštil, J; Arnold, Z

    2012-08-01

    A system for direct measurements of the magneto-caloric effect (MCE) exploits a rapid transport of a sample into or from magnetic field in permanent Halbach-type (1 T) or superconducting (4.7 T) magnets. Time dependence of induced changes of the sample temperature, ΔT(t), is detected directly by the differential Cu-Constantan-Cu micro-thermocouples with time steps of 300 ms. A sample placed inside an evacuated simple LN(2) cryostat is either totally isolated (adiabatic conditions) or partly connected with the copper sample holder (non-adiabatic conditions). The last arrangement (a model of the Brayton cycle) is used to simulate an application of MCE in refrigeration techniques. The relations describing ΔT(t) that allow an analysis of MCE of the studied materials are based on the general cooling law. The effect of the first-order magnetic transition on MCE of selected sample is also demonstrated by non-standard ΔT(t) curves measured in the last mentioned experimental arrangements.

  14. Comparison of two surface temperature measurement using thermocouples and infrared camera

    Directory of Open Access Journals (Sweden)

    Michalski Dariusz

    2017-01-01

    Full Text Available This paper compares two methods applied to measure surface temperatures at an experimental setup designed to analyse flow boiling heat transfer. The temperature measurements were performed in two parallel rectangular minichannels, both 1.7 mm deep, 16 mm wide and 180 mm long. The heating element for the fluid flowing in each minichannel was a thin foil made of Haynes-230. The two measurement methods employed to determine the surface temperature of the foil were: the contact method, which involved mounting thermocouples at several points in one minichannel, and the contactless method to study the other minichannel, where the results were provided with an infrared camera. Calculations were necessary to compare the temperature results. Two sets of measurement data obtained for different values of the heat flux were analysed using the basic statistical methods, the method error and the method accuracy. The experimental error and the method accuracy were taken into account. The comparative analysis showed that although the values and distributions of the surface temperatures obtained with the two methods were similar but both methods had certain limitations.

  15. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    Directory of Open Access Journals (Sweden)

    Abdil Kus

    2015-01-01

    Full Text Available In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  16. Thermocouple and infrared sensor-based measurement of temperature distribution in metal cutting.

    Science.gov (United States)

    Kus, Abdil; Isik, Yahya; Cakir, M Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-12

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  17. Expansion Compression Contacts for Thermoelectric Legs

    Science.gov (United States)

    Sakamoto, Jeffrey

    2009-01-01

    In a proposed alternative to previous approaches to making hot-shoe contacts to the legs of thermoelectric devices, one relies on differential thermal expansion to increase contact pressures for the purpose of reducing the electrical resistances of contacts as temperatures increase. The proposed approach is particularly applicable to thermoelectric devices containing p-type (positive-charge-carrier) legs made of a Zintl compound (specifically, Yb14MnSb11) and n-type (negative charge-carrier) legs made of SiGe. This combination of thermoelectric materials has been selected for further development, primarily on the basis of projected thermoelectric performance. However, it is problematic to integrate, into a practical thermoelectric device, legs made of these materials along with a metal or semiconductor hot shoe that is required to be in thermal and electrical contact with the legs. This is partly because of the thermal-expansion mismatch of these materials: The coefficient of thermal expansion (CTE) of SiGe is 4.5 x 10(exp -6) C (exp -1), while the CTE of Yb14MnSb11 is 20 x 10(exp -6) C(exp -1). Simply joining a Yb14MnSb11 and a SiGe leg to a common hot shoe could be expected to result in significant thermal stresses in either or both legs during operation. Heretofore, such thermal stresses have been regarded as disadvantageous. In the proposed approach, stresses resulting from the CTE mismatch would be turned to advantage.

  18. Correct utilization of thermocouple compensation conductor%热电偶补偿导线的正确使用

    Institute of Scientific and Technical Information of China (English)

    张丽

    2012-01-01

    The thesis introduces the utilization principles of compensation conductor, analyzes the impact of operation errors upon thermocouple temperature measuring results, and puts forward correct compensation conduction utilization methods, with a view to thermocouple temperature measuring error influencing other thermal controlling aspects.%对补偿导线的使用原理进行了介绍,阐述了操作错误对热电偶温度测量结果的影响,并提出补偿导线的正确使用方法,以避免热电偶的测温结果出现较大误差影响热控工作其他环节。

  19. The relationship of leg volume and leg mass with anaerobic performance and knee strength in wrestlers

    Directory of Open Access Journals (Sweden)

    Erdal ZORBA

    2010-01-01

    Full Text Available The purpose of the present study was to determination of the relationship between leg volume, leg mass with anaerobic performance and knee strength in wrestlers. 31 wrestlers from a university students participated in this study voluntarily (age: 21.09 ± 0.99 yrs. Circumferential measurement were used for the determination of leg volume by Frustum Method and after that, a regression formula was used. For this formulas, while the R square (R2 value was .95 and the standart error value was .056. Leg mass was determined by the Hanavan Method. Wingate Anaerobic Power Test (WAnT was used for the determination of anaerobic performance and Isometric Knee Dynamometer was used for the determination of knee strength. Results of Pearson Product Moment correlation analysis, leg volume was significantly correlated with leg mass (r=.993; p<0.01, peak power (r=.523; p<0.01 and mean power (r=.585; p<0.01. Similarly leg mass was significantly correlated with peak power (r=.654; p<0.01 and mean power (r=.704; p<0.01. In addition, peak power was found to be significantly correlated with leg strength (r=.430; p<0.05 and mean power (r=.613; p<0.01. As a conclusion, the findings of the present study indicated that leg volume and leg mass plays important role in anaerobic performance in wrestlers and isometric knee strength was found to be correlated with anaerobic performance.

  20. External Attachment of Titanium Sheathed Thermocouples to Zirconium Nuclear Fuel Rods For The Loss-Of-Fluid-Test (LOFT) Reactor

    Science.gov (United States)

    Welty, Richard K.

    1980-10-01

    The Exxon Nuclear Company, Inc. acting as a Subcontractor to EG&G Idaho Inc.3 Idaho National Engineering Laboratory, Idaho Falls, Idaho, has developed a welding process to attach titanium sheathed thermocouples to the outside of the zircaloy clad fuel rods. The fuel rods and thermocouples are used to test simulated loss-of-coolant-accident (LOCA) conditions in a pressurized water reactor (LOFT Reactor, Idaho National Laboratory). The design goals were to (1) reliably attach thermocouples to the zircaloy fuel rods, (2) achieve or exceed a life expectancy of 6,000 hours of reactor operation in a borated water environment of 316°C at 2260 psi, (3) provide and sustain repeatable physical and metallurgical properties in the instrumented rods subjected to transient temperatures up to 1538°C with blowdown, shock, loading, and fast quench. A laser beam was selected as the optimum welding process because of the extremely high energy input per unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A commercial pulsed laser and energy control system was installed along with specialized welding fixtures. Laser room facility requirements and tolerances were established. Performance qualifications and detailed welding procedures were also developed. Product performance tests were conducted to assure that engineering design requirements could be met on a production basis. Irradiation tests showed no degradation of thermocouples or weld structure. Fast thermal cycle and heater rod blowdown reflood tests were made to subject the weldments to high temperatures, high pressure steam, and fast water quench cycles. From the behavior of these tests, it was concluded that the attachment welds would survive a series of reactor safety tests.

  1. Cold Stress and the Cold Pressor Test

    Science.gov (United States)

    Silverthorn, Dee U.; Michael, Joel

    2013-01-01

    Temperature and other environmental stressors are known to affect blood pressure and heart rate. In this activity, students perform the cold pressor test, demonstrating increased blood pressure during a 1- to 2-min immersion of one hand in ice water. The cold pressor test is used clinically to evaluate autonomic and left ventricular function. This…

  2. Transiliac Leg Lengthening in Poliomyelitis

    Directory of Open Access Journals (Sweden)

    Baghdadi Taghi

    2009-10-01

    Full Text Available The development and widespread use of a prophylactic vaccine significantly reduced the incidence of poliomyelitis. At present we more commonly encounter with poliomyelitis sequelae especially in developing countries. We evaluate the results of a modified innominate osteotomy for leg length discrepancy in poliomyelitis. Instead of triangular bone graft as in Salter’s innominate osteotomy , a trapezoidal bone graft from the ilium is inserted in the site of osteotomy after gradual distraction of the limb. 25 patients (9 males and 16 females with mean age of 25 years (17-37 years were treated by this method. All of them had poliomyelitis with limb shortening. At a mean follow-up of 7 years (3 months to 17 years an average of 3 cm (2.5-3.5 was achieved. Complication was seen in three patients including injury to the lateral cutaneouns nerve of thigh and displacement of osteotomy in two patients .except in one all of the patients satisfied with the operation. We believe this method is safe, effective and cost-benefit for treating of moderate shortening of the lower limb in poliomyelitis.

  3. Pharmacotherapy for restless legs syndrome.

    Science.gov (United States)

    Ferini-Strambi, Luigi; Marelli, Sara

    2014-06-01

    Restless legs syndrome (RLS) is a common condition characterized by paresthesia and an urge to move. Predominantly, symptoms occur at rest in the evening or at night, and they are alleviated by moving the affected extremity. RLS prevalence in the general population has been estimated to be approximately 5%. This review presents all options for the treatment of RLS. Pharmacological treatment should be limited to those patients who suffer from clinically relevant RLS, that is, when symptoms impair the patient's quality of life, daytime functioning, social functioning or sleep. Treatment on demand is a clinical need in some RLS patients, and medications include carbidopa/levodopa, pramipexole, ropinirole, oxycodone, methadone, codeine and tramadol. Chronic RLS should be treated with either a nonergot dopamine agonist or an α-2-δ calcium channel ligand. A dopamine agonist is a more appropriate choice in the presence of depression and overweight. As α-2-δ ligands can alleviate chronic pain and may be helpful in treating anxiety and insomnia, the presence of any of these comorbidities may favor their use. For RLS present through much of the day and night, the use of long-acting agents, such as the rotigotine patch or gabapentin enacarbil should be considered. In refractory RLS, oral prolonged release oxycodone-naloxone should be considered.

  4. Comparisons of Gas-phase Temperature Measurements in a Flame Using Thin-Filament Pyrometry and Thermocouples

    Science.gov (United States)

    Struk, Peter; Dietrich, Daniel; Valentine, Russell; Feier, Ioan

    2003-01-01

    Less-intrusive, fast-responding, and full-field temperature measurements have long been a desired tool for the research community. Recently, the emission of a silicon-carbide (SiC) fiber placed in a flowing hot (or reacting) gas has been used to measure the temperature profile along the length of the fiber. The relationship between the gas and fiber temperature comes from an energy balance on the fiber. In the present work, we compared single point flame temperature measurements using thin-filament pyrometry (TFP) and thermocouples. The data was from vertically traversing a thermocouple and a SiC fiber through a methanol/air diffusion flame of a porous-metal wick burner. The results showed that the gas temperature using the TFP technique agreed with the thermocouple measurements (25.4 m diameter wire) within 3.5% for temperatures above 1200 K. Additionally, we imaged the entire SiC fiber (with a spatial resolution of 0.14 mm) while it was in the flame using a high resolution CCD camera. The intensity level along the fiber length is a function of the temperature. This results in a one-dimensional temperature profiles at various heights above the burner wick. This temperature measurement technique, while having a precision of less than 1 K, showed data scatter as high as 38 K. Finally, we discuss the major sources of uncertainty in gas temperature measurement using TFP.

  5. 热电偶测温系统设计%Design of thermocouple system for temperature measurement

    Institute of Scientific and Technical Information of China (English)

    李彦芳

    2013-01-01

    用热电偶测量温度是航空温度测量中应用最广泛的一种方式,常用来测量高温气流及高速气流.提出了一种可以应用于管道内流体测量的热电偶测温系统的设计方法:以热电偶作为感温元件,配合变换器实现准确可靠的温度测量,输出的电压信号与对应温度成线性关系.通过设计实例及试验,验证了系统的精度性能,实现了预期的设计目标.%Thermocouple is widely used in aviation field for temperature measurement,often used to measure air flow of high temperature or high speed.Proposed a thermocouple system for piping fluid:thermocouple as temperature sensing element,with the transducer to achieve accurate and reliable measurement result,the output voltage signal is linear with the corresponding temperature.By design examples and test results,to verify the accuracy of the system performance,to achieve the expected goals of design.

  6. New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M.; Vlahovic, L.; Rondinella, V.V. [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe, (Germany); Sadli, M.; Failleau, G. [Laboratoire Commun de Metrologie, LNE-Cnam, Saint-Denis, (France); Fuetterer, M.; Lapetite, J.M. [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten, (Netherlands); Fourrez, S. [Thermocoax, 8 rue du pre neuf, F-61100 St Georges des Groseillers, (France)

    2015-07-01

    Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand high temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)

  7. Cold and Cough Medicines

    Science.gov (United States)

    ... What can you do for your cold or cough symptoms? Besides drinking lots of fluids and getting ... medicines. There are lots of different cold and cough medicines, and they do different things. Nasal decongestants - ...

  8. Cold-induced metabolism

    NARCIS (Netherlands)

    van Marken Lichtenbelt, W.D.; Daanen, A.M.

    2003-01-01

    Cold-induced metabolism. van Marken Lichtenbelt WD, Daanen HA. Department of Human Biology, Maastricht University, Maastricht, The Netherlands. PURPOSE OF REVIEW: Cold response can be insulative (drop in peripheral temperature) or metabolic (increase in energy expenditure). Nonshivering thermogenesi

  9. Cold nuclear fusion

    National Research Council Canada - National Science Library

    Huang Zhenqiang Huang Yuxiang

    2013-01-01

    ...... And with a magnetic moment of light nuclei controlled cold nuclear collide fusion, belongs to the nuclear energy research and development in the field of applied technology "cold nuclear collide fusion...

  10. 贵金属铠装热电偶的发展及应用%The Development and Application of Armored Thermocouple of Precious Metals

    Institute of Scientific and Technical Information of China (English)

    张健康; 刘毅; 李伟; 虞坤; 许昆; 罗锡明

    2016-01-01

    贵金属铠装热电偶具有特殊的结构和特性,对套管、偶丝、绝缘材料进行了介绍,列出了贵金属铠装热电偶相关标准,并介绍了其应用领域。对贵金属铠装热电偶的发展方向进行了展望。%The armored thermocouple of precious metals have special structures and properties. The thermowell, thermocouple wires, insulation material were introduced, the standards were listed and the applications of armored thermocouple of precious metals were described. Lastly, the development trends of armored thermocouple of precious metals were proposed.

  11. The relationship of leg volume and leg mass with anaerobic performance and knee strength in wrestlers

    Directory of Open Access Journals (Sweden)

    Erdal Zorba

    2010-01-01

    Full Text Available The purpose of the present study was to determination of the relationship between leg volume, leg mass with anaerobic performance and knee strength in wrestlers. 31 wrestlers from a university students participated in this study voluntarily (X age: 21.09 ± 0.99 yrs. Circumferential measurement were used for the determination of leg volume by Frustum Method and after that, a regression formula was used. For this formulas, while the R square (R2 value was .95 and the standart error value was .056. Leg mass was determined by the Hanavan Method. Wingate Anaerobic Power Test (WAnT was used for the determination of anaerobic performance and Isometric Knee Dynamometer was used for the determination of knee strength. Results of Pearson Product Moment correlation analysis, leg volume was significantly correlated with leg mass (r=.993; pnee strength was found to be correlated with anaerobic performance.

  12. Clinical quality indicators of venous leg ulcers

    DEFF Research Database (Denmark)

    Kjaer, Monica L; Mainz, Jan; Soernsen, Lars T

    2005-01-01

    In the clinical setting, diagnosis and treatment of venous leg ulcers can vary considerably from patient to patient. The first step to reducing this variation is to document venous leg ulcer care through use of quantitative scientific documentation principles. This requires the development of valid...... and reliable evidence-based quality indicators of venous leg ulcer care. A Scandinavian multidisciplinary, cross-sectional panel of wound healing experts developed clinical quality indicators on the basis of scientific evidence from the literature and subsequent group nominal consensus of the panel......; an independent medical doctor tested the feasibility and reliability of these clinical indicators, assessing the quality of medical technical care on 100 consecutive venous leg ulcer patients. Main outcome measures were healing, recurrence, pain, venous disease diagnosis, differential diagnosis and treatment...

  13. Poison ivy on the leg (image)

    Science.gov (United States)

    This is a typical early appearance of a poison ivy rash, located on the leg. These early lesions ... line where the skin has brushed against the poison ivy plant. The rash is caused by skin contact ...

  14. Support Leg Loading in Punt Kicking

    Science.gov (United States)

    Kermond, John; Konz, Stephen

    1978-01-01

    Maximum distance in football punt kicking is associated with a maximum force transfer to the ball rather than a maximum force transfer through the ground via the support leg. For maximum distance, tred lightly. (Author)

  15. Leg or foot amputation - dressing change

    Science.gov (United States)

    ... gov/ency/patientinstructions/000018.htm Leg or foot amputation - dressing change To use the sharing features on ... guideline for management for rehabilitation of lower limb amputation. January 2008. www.healthquality.va.gov/guidelines/Rehab/ ...

  16. [Pentoxifylline medication within the scope of leg-ulcer therapy. Results of a field study using Trental 400].

    Science.gov (United States)

    Pemler, K; Penth, B; Adams, H J

    1979-06-07

    513 patients with chronic ulcers of the leg were treated with Trental 400 orally in addition to local therapy. Regarding the reduction of the symptoms: ulcer extension, coldness of the leg, paraesthesia, resting pain and improvement of walking distance, 215 patients were classified as considerably improved, 195 distinctly improved, 53 slightly improved and 44 unchanged. Four cases worsened, two cases could not be classified. The possibility of combining oral therapy with local treatment and surgical measures (skin-flaps) is shown in three case reports. Gastro-intestinal tolerance of Trental 400 was good, interactions with concomitantly administered drugs were not reported.

  17. Microgravity, Mesh-Crawling Legged Robots

    Science.gov (United States)

    Behar, Alberto; Marzwell, Neville; Matthews, Jaret; Richardson, Krandalyn; Wall, Jonathan; Poole, Michael; Foor, David; Rodgers, Damian

    2008-01-01

    The design, fabrication, and microgravity flight-testing are part of a continuing development of palm-sized mobile robots that resemble spiders (except that they have six legs apiece, whereas a spider has eight legs). Denoted SpiderBots (see figure), they are prototypes of proposed product line of relatively inexpensive walking robots that could be deployed in large numbers to function cooperatively in construction, repair, exploration, search, and rescue activities in connection with exploration of outer space and remote planets.

  18. Three cross leg flaps for lower leg reconstruction of Gustilo type III C open fracture

    Directory of Open Access Journals (Sweden)

    Kazufumi Sano

    2016-01-01

    Full Text Available A 60 year old male had Gustilo type III C open fracture of the right lower leg. After radical debridement, the large open defect including certain loss of the bone tissue was successfully augmented and covered, by consecutive three cross-leg flaps, which consisted of the free rectus abdominis musculocutaneous flap, the fibula osteocutaneous flap and the conventional sural flap. Although indication for amputation or preservation is decided with multiple factors in each case, a strategic combination of cross-leg flap, free flap, external fixation and vascular delay could increase the potential of preservation of the lower leg with even disastrous Gustilo type III C.

  19. Long Hole Film Cooling Dataset for CFD Development . Part 1; Infrared Thermography and Thermocouple Surveys

    Science.gov (United States)

    Shyam, Vikram; Thurman, Douglas; Poinsatte, Phillip; Ameri, Ali; Eichele, Peter; Knight, James

    2013-01-01

    An experiment investigating flow and heat transfer of long (length to diameter ratio of 18) cylindrical film cooling holes has been completed. In this paper, the thermal field in the flow and on the surface of the film cooled flat plate is presented for nominal freestream turbulence intensities of 1.5 and 8 percent. The holes are inclined at 30deg above the downstream direction, injecting chilled air of density ratio 1.0 onto the surface of a flat plate. The diameter of the hole is 0.75 in. (0.01905 m) with center to center spacing (pitch) of 3 hole diameters. Coolant was injected into the mainstream flow at nominal blowing ratios of 0.5, 1.0, 1.5, and 2.0. The Reynolds number of the freestream was approximately 11,000 based on hole diameter. Thermocouple surveys were used to characterize the thermal field. Infrared thermography was used to determine the adiabatic film effectiveness on the plate. Hotwire anemometry was used to provide flowfield physics and turbulence measurements. The results are compared to existing data in the literature. The aim of this work is to produce a benchmark dataset for Computational Fluid Dynamics (CFD) development to eliminate the effects of hole length to diameter ratio and to improve resolution in the near-hole region. In this report, a Time-Filtered Navier Stokes (TFNS), also known as Partially Resolved Navier Stokes (PRNS), method that was implemented in the Glenn-HT code is used to model coolant-mainstream interaction. This method is a high fidelity unsteady method that aims to represent large scale flow features and mixing more accurately.

  20. Exploring Soot Particle Concentration and Emissivity by Transient Thermocouples Measurements in Laminar Partially Premixed Coflow Flames

    Directory of Open Access Journals (Sweden)

    Gianluigi De Falco

    2017-02-01

    Full Text Available Soot formation in combustion represents a complex phenomenon that strongly depends on several factors such as pressure, temperature, fuel chemical composition, and the extent of premixing. The effect of partial premixing on soot formation is of relevance also for real combustion devices and still needs to be fully understood. An improved version of the thermophoretic particle densitometry (TPD method has been used in this work with the aim to obtain both quantitative and qualitative information of soot particles generated in a set of laminar partially-premixed coflow flames characterized by different equivalence ratios. To this aim, the transient thermocouple temperature response has been analyzed to infer particle concentration and emissivity. A variety of thermal emissivity values have been measured for flame-formed carbonaceous particles, ranging from 0.4 to 0.5 for the early nucleated soot particles up to the value of 0.95, representing the typical value commonly attributed to mature soot particles, indicating that the correct determination of the thermal emissivity is necessary to accurately evaluate the particle volume fraction. This is particularly true at the early stage of the soot formation, when particle concentration measurement is indeed particularly challenging as in the central region of the diffusion flames. With increasing premixing, an initial increase of particles is detected both in the maximum radial soot volume fraction region and in the central region of the flame, while the further addition of primary air determines the particle volume fraction drop. Finally, a modeling analysis based on a sectional approach has been performed to corroborate the experimental findings.

  1. Passive legged, multi-segmented, robotic vehicle.

    Energy Technology Data Exchange (ETDEWEB)

    Hayward, David R.

    2003-11-01

    The Passive-legged, Multi-segmented, Robotic Vehicle concept is a simple legged vehicle that is modular and scaleable, and can be sized to fit through confined areas that are slightly larger than the size of the vehicle. A specific goal of this project was to be able to fit through the opening in the fabric of a chain link fence. This terrain agile robotic platform will be composed of multiple segments that are each equipped with appendages (legs) that resemble oars extending from a boat. Motion is achieved by pushing with these legs that can also flex to fold next to the body when passing through a constricted area. Each segment is attached to another segment using an actuated joint. This joint represents the only actuation required for mobility. The major feature of this type of mobility is that the terrain agility advantage of legs can be attained without the complexity of the multiple-actuation normally required for the many joints of an active leg. The minimum number of segments is two, but some concepts require three or more segments. This report discusses several concepts for achieving this type of mobility, their design, and the results obtained for each.

  2. Sympathetic adaptations to one-legged training

    Science.gov (United States)

    Ray, C. A.

    1999-01-01

    The purpose of the present study was to determine the effect of leg exercise training on sympathetic nerve responses at rest and during dynamic exercise. Six men were trained by using high-intensity interval and prolonged continuous one-legged cycling 4 day/wk, 40 min/day, for 6 wk. Heart rate, mean arterial pressure (MAP), and muscle sympathetic nerve activity (MSNA; peroneal nerve) were measured during 3 min of upright dynamic one-legged knee extensions at 40 W before and after training. After training, peak oxygen uptake in the trained leg increased 19 +/- 2% (P training (108 +/- 5 to 96 +/- 5 beats/min and 132 +/- 8 to 119 +/- 4 mmHg, respectively, during the third minute of exercise; P training. However, MSNA was significantly less during the third minute of exercise after training (32 +/- 2 to 22 +/- 3 bursts/min; P training effect on MSNA remained when MSNA was expressed as bursts per 100 heartbeats. Responses to exercise in five untrained control subjects were not different at 0 and 6 wk. These results demonstrate that exercise training prolongs the decrease in MSNA during upright leg exercise and indicates that attenuation of MSNA to exercise reported with forearm training also occurs with leg training.

  3. Ankle Joint Angle and Lower Leg Musculotendinous Unit Responses to Cryotherapy.

    Science.gov (United States)

    Akehi, Kazuma; Long, Blaine C; Warren, Aric J; Goad, Carla L

    2016-09-01

    Akehi, K, Long, BC, Warren, AJ, and Goad, CL. Ankle joint angle and lower leg musculotendinous unit responses to cryotherapy. J Strength Cond Res 30(9): 2482-2492, 2016-The use of cold application has been debated for its influence on joint range of motion (ROM) and stiffness. The purpose of this study was to determine whether a 30-minute ice bag application to the plantarflexor muscles or ankle influences passive ankle dorsiflexion ROM and lower leg musculotendinous stiffness (MTS). Thirty-five recreationally active college-aged individuals with no history of lower leg injury 6 months before data collection volunteered. On each testing day, we measured maximum passive ankle dorsiflexion ROM (°) and plantarflexor torque (N·m) on an isokinetic dynamometer to calculate the passive plantarflexor MTS (N·m per degree) at 4 joint angles before, during, and after a treatment. Surface electromyography amplitudes (μV), and skin surface and ambient air temperature (°C) were also measured. Subjects received an ice bag to the posterior lower leg, ankle joint, or nothing for 30 minutes in different days. Ice bag application to the lower leg and ankle did not influence passive ROM (F(12,396) = 0.67, p = 0.78). Passive torque increased after ice bag application to the lower leg (F(12,396) = 2.21, p = 0.011). Passive MTS at the initial joint angle increased after ice bag application to the lower leg (F(12,396) = 2.14, p = 0.014) but not at the other joint angles (p > 0.05). Surface electromyography amplitudes for gastrocnemius and soleus muscles increased after ice application to the lower leg (F(2,66) = 5.61, p = 0.006; F(12,396) = 3.60, p < 0.001). Ice bag application to the lower leg and ankle joint does not alter passive dorsiflexion ROM but increases passive ankle plantarflexor torque in addition to passive ankle plantarflexor MTS at the initial joint angle.

  4. [Responses of Arma chinensis cold tolerance to rapid cold hardening and underlying physiological mechanisms].

    Science.gov (United States)

    Li, Xing-Peng; Song, Li-Wen; Zhang, Hong-Hao; Chen, Yue-Qu; Zuo, Tong-Tong; Wang, Jun; Sun, Wei

    2012-03-01

    Rapid cold hardening can enhance the cold tolerance of some insects. To explore the effects of different cold hardening induction temperature on the cold tolerance of Arma chinensis and related physiological mechanisms, the 3rd generation A. chinensis adults reared indoor were treated with cooling at 15, 10, and 4 degrees C for 4 h, respectively, or with gradual cooling from 15 degrees C for 4 h to 10 degrees C for 4 h, and finally to 4 degrees C for 4 h. The super-cooling point, water content, and the contents of low molecular carbohydrates, glycerol, and amino acids of the adults after cooling and the adults cold tolerance at 0, -5, and -10 degrees C were measured by thermocouple, high performance liquid chromatography, and other analytical techniques. When exposed at -10 degrees C after cooling, the survival rate of the adults treated with gradual cooling or treated with cooling at 4 degrees C for 4 h was averagely 58.3%, while that of the adults reared at room temperature (25 degrees C +/- 2 degrees C) or treated with cooling at 15 degrees C or 10 degrees C for 4 h decreased significantly, with an average of 8.9%. The super-cooling point of the adults treated with gradual cooling or with cooling at 4 degrees C for 4 h was -15.6 degrees C, which was averagely 1.3 degrees C lower than that of the other treatments. The water content of the adults had no significant difference among all treatments, with an average of 61.8%, but the glucose, sorbitolum, glycerol, Ala, and Glu contents in treatments gradual cooling and cooling at 4 degrees C for 4 h increased by 2.82-fold, 2.65-fold, 3.49-fold, 51.3%, and 80.2%, while the fucose, mannose, and Pro contents decreased by 68.4%, 52.2%, and 30.2%, respectively, as compared with the other treatments. The fructose content showed no significant difference among all treatments. It was suggested that rapid cool hardening had a critical temperature to induce the physiological metabolism process of adult A. chinensis, and

  5. Genetic parameters for claw and leg health, foot and leg conformation, and locomotion in Danish Holsteins

    DEFF Research Database (Denmark)

    Laursen, M. V.; Boelling, D.; Mark, Thomas

    2009-01-01

    The purpose of this study was to estimate the genetic correlations among claw and leg health and potential indicator traits. Claw health was defined as absence of heel horn erosion, interdigital dermatitis, interdigital phlegmon, interdigital hyperplasia, laminitis, and sole ulcer. Leg health...

  6. One-legged endurance training: leg blood flow and oxygen extraction during cycling exercise

    DEFF Research Database (Denmark)

    Rud, B; Foss, O; Krustrup, Peter

    2012-01-01

    Aim: As a consequence of enhanced local vascular conductance, perfusion of muscles increases with exercise intensity to suffice the oxygen demand. However, when maximal oxygen uptake (VO(2) max) and cardiac output are approached, the increase in conductance is blunted. Endurance training increases...... muscle metabolic capacity, but to what extent that affects the regulation of muscle vascular conductance during exercise is unknown. Methods: Seven weeks of one-legged endurance training was carried out by twelve subjects. Pulmonary VO(2) during cycling and one-legged cycling was tested before and after...... training, while VO(2) of the trained leg (TL) and control leg (CL) during cycling was determined after training. Results: VO(2) max for cycling was unaffected by training, although one-legged VO(2) max became 6.7 (2.3)% (mean ± SE) larger with TL than with CL. Also TL citrate synthase activity was higher...

  7. Temperature measurement errors with thermocouples inside 27 MHz current source interstitial hyperthermia applicators.

    Science.gov (United States)

    Kaatee, R S; Crezee, H; Visser, A G

    1999-06-01

    The multielectrode current source (MECS) interstitial hyperthermia (IHT) system uses thermocouple thermometry. To obtain a homogeneous temperature distribution and to limit the number of traumas due to the implanted catheters, most catheters are used for both heating and thermometry. Implications of temperature measurement inside applicators are discussed. In particular, the impact of self-heating of both the applicator and the afterloading catheter were investigated. A one-dimensional cylindrical model was used to compute the difference between the temperature rise inside the applicators (deltaTin) and in the tissue just outside the afterloading catheter (deltaTout) as a function of power absorption in the afterloading catheter, self-heating of the applicator and the effective thermal conductivity of the surrounding tissue. Furthermore, the relative artefact (ERR), i.e. (deltaTin - deltaTout)/deltaTin, was measured in a muscle equivalent agar phantom at different positions in a dual-electrode applicator and for different catheter materials. A method to estimate the tissue temperature by power-off temperature decay measurement inside the applicator was investigated. Using clinical dual-electrode applicators in standard brachytherapy catheters in a muscle-equivalent phantom, deltaTin is typically twice as high as deltaTout. The main reason for this difference is self-heating of the thin feeder wires in the centre of the applicator. The measurement error caused by energy absorption in the afterloading catheter is small, i.e. even for materials with a high dielectric loss factor it is less than 5%. About 5 s after power has been switched off, Tin in the electrodes represents the maximum tissue temperature just before power-off. This delay time (t(delay)) and ERR are independent of Tin. However, they do depend on the thermal properties of the tissue. Therefore, ERR and t(delay) and their stability in perfused tissues have to be investigated to enable a reliable

  8. Study of Thermocurrents in ILC cavities via measurements of the Seebeck Effect in niobium, titanium, and stainless steel thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, Victoria [Univ. of Wisconsin, Madison, WI (United States)

    2014-01-01

    The goals of Fermilab’s Superconductivity and Radio Frequency Development Department are to engineer, fabricate, and improve superconducting radio frequency (SCRF) cavities in the interest of advancing accelerator technology. Improvement includes exploring possible limitations on cavity performance and mitigating such impediments. This report focuses on investigating and measuring the Seebeck Effect observed in cavity constituents titanium, niobium, and stainless steel arranged in thermocouples. These junctions exist between cavities, helium jackets, and bellows, and their connection can produce a loop of electrical current and magnetic flux spontaneously during cooling. The experimental procedure and results are described and analyzed. Implications relating the results to cavity performance are discussed.

  9. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

    Energy Technology Data Exchange (ETDEWEB)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal [FEMTO-ST Institute UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, 15B Avenue des Montboucons, F-25030 Besançon (France)

    2016-06-15

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  10. Attachment of lead wires to thin film thermocouples mounted on high temperature materials using the parallel gap welding process

    Science.gov (United States)

    Holanda, Raymond; Kim, Walter S.; Pencil, Eric; Groth, Mary; Danzey, Gerald A.

    1990-01-01

    Parallel gap resistance welding was used to attach lead wires to sputtered thin film sensors. Ranges of optimum welding parameters to produce an acceptable weld were determined. The thin film sensors were Pt13Rh/Pt thermocouples; they were mounted on substrates of MCrAlY-coated superalloys, aluminum oxide, silicon carbide and silicon nitride. The entire sensor system is designed to be used on aircraft engine parts. These sensor systems, including the thin-film-to-lead-wire connectors, were tested to 1000 C.

  11. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method).

    Science.gov (United States)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal

    2016-06-01

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  12. Dimensional synthesis of a leg mechanism

    Science.gov (United States)

    Pop, F.; Lovasz, E.-Ch; Pop, C.; Dolga, V.

    2016-08-01

    An eight bar leg mechanism dimensional synthesis is presented. The mathematical model regarding the synthesis is described and the results obtained after computation are verified with help of 2D mechanism simulation in Matlab. This mechanism, inspired from proposed solution of Theo Jansen, is integrated into the structure of a 2 DOF quadruped robot. With help of the kinematic synthesis method described, it is tried to determine new dimensions for the mechanism, based on a set of initial conditions. These are established by taking into account the movement of the end point of the leg mechanism, which enters in contact with the ground, during walking. An optimization process based on the results obtained can be conducted further in order to find a better solution for the leg mechanism.

  13. Dipoles on a Two-leg Ladder

    DEFF Research Database (Denmark)

    Gammelmark, Søren; Zinner, Nikolaj Thomas

    2013-01-01

    We study polar molecules with long-range dipole-dipole interactions confined to move on a two-leg ladder for different orientations of the molecular dipole moments with respect to the ladder. Matrix product states are employed to calculate the many-body ground state of the system as function...... of lattice filling fractions, perpendicular hopping between the legs, and dipole interaction strength. We show that the system exhibits zig-zag ordering when the dipolar interactions are predominantly repulsive. As a function of dipole moment orientation with respect to the ladder, we find...... that there is a critical angle at which ordering disappears. This angle is slightly larger than the angle at which the dipoles are non-interacting along a single leg. This behavior should be observable using current experimental techniques....

  14. AN EFFECTIVE HUMAN LEG MODELING METHOD

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Digital medicine is a new concept in medical field, and the need for digital human body is increasing these years. This paper used Free Form Deformation (FFD) to model the motion of human leg. It presented the motion equations of knee joint on the basis of anatomic structure and motion characters, then transmitted the deformation to the mesh of leg through a simplified FFD that only used two-order B-spline basis function. The experiments prove that this method can simulate the bend of leg and the deformation of muscles fairly well. Compared with the method of curved patches, this method is more convenient and effective. Further more, those equations can be easily applied to other joint models of human body.

  15. Leg Spasticity and Ambulation in Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Swathi Balantrapu

    2014-01-01

    Full Text Available Background. Spasticity of the legs is common in multiple sclerosis (MS, but there has been limited research examining its association with ambulatory outcomes. Objective. This study examined spasticity of the legs and its association with multiple measures of ambulation in persons with MS. Methods. The sample included 84 patients with MS. Spasticity of the legs was measured using a 5-point rating scale ranging between 0 (normal and 4 (contracted. Patients completed the 6-minute walk (6 MW, timed 25 foot walk (T25FW, and timed up-and-go (TUG, and O2 cost of walking was measured during the 6 MW. The patients undertook two walking trials on a GAITRite (CIR systems, Inc. for measuring spatial and temporal parameters of gait. The patients completed the Multiple Sclerosis Walking Scale-12 (MSWS-12 and wore an accelerometer over a seven-day period. Results. 52% (n=44 of the sample presented with spasticity of the legs. Those with leg spasticity had significantly worse ambulation as measured by 6 MW (P=0.0001, d=-0.86, T25FW (P=0.003,d=0.72, TUG (P=0.001, d=0.84, MSWS-12 (P=0.0001,d=1.09, O2 cost of walking (P=0.001, d=0.75, average steps/day (P<0.05, d=-0.45, and walking velocity (P<0.05, d=-0.53 and cadence (P<0.05, d=-0.46. Conclusion. Leg spasticity was associated with impairments in ambulation, including alterations in spatiotemporal parameters and free-living walking.

  16. Six weeks' aerobic retraining after two weeks' immobilization restores leg lean mass and aerobic capacity but does not fully rehabilitate leg strenght in young and older men

    DEFF Research Database (Denmark)

    Vigelsø Hansen, Andreas; Gram, Martin; Wiuff, Caroline

    2015-01-01

    OBJECTIVE: To determine the effect of aerobic retraining as rehabilitation after short-term leg immobilization on leg strength, leg work capacity, leg lean mass, leg muscle fibre type composition and leg capillary supply, in young and older men. SUBJECTS AND DESIGN: Seventeen young (23 ± 1 years)...

  17. The Molecular Genetics of Restless Legs Syndrome.

    Science.gov (United States)

    Rye, David B

    2015-09-01

    Restless legs syndrome (RLS) is a common sensorimotor trait defined by symptoms that interfere with sleep onset and maintenance in a clinically meaningful way. Nonvolitional myoclonus while awake and asleep is a sign of the disorder and an informative endophenotype. The genetic contributions to RLS/periodic leg movements are substantial, are among the most robust defined to date for a common disease, and account for much of the variance in disease expressivity. The disorder is polygenic, as revealed by recent genome-wide association studies. Experimental studies are revealing mechanistic details of how these common variants might influence RLS expressivity.

  18. The mysteries of restless legs syndrome.

    Science.gov (United States)

    Martin, Caren McHenry

    2007-11-01

    Restless legs syndrome (RLS) is a sensorimotor disorder characterized by the uncontrollable urge to move the legs. This urge can often be accompanied by pain or other unpleasant sensations, and it either occurs or worsens with rest. Affecting an estimated 6% to 15% of the adult population, RLS compromises the patient's ability to sleep and can significantly decrease quality of life. Because diagnosis currently relies solely on patient (or caregiver) interview, recognizing the symptoms of RLS and knowing what medications treat this condition--as well as the many that exacerbate it--is important for all health care practitioners.

  19. Calculation of the Uncertainty of Cheap Metal Thermocouple%廉金属热电偶的不确定度计算

    Institute of Scientific and Technical Information of China (English)

    刘晔

    2016-01-01

    目前用量最大的廉金属热电偶是镍铬-镍硅热电偶(K型热电偶),为保证计量性能的准确可靠,采用双极法对其进行检定,用一等标准铂铑10-铂热电偶检定一支K型II级热电偶,检定点选取1000℃。文章重点介绍了该检定方法和示值误差的不确定度评定。%The current most widely used cheap metal thermocouple is chromel-silicel thermocouple (K type thermocouple). In order to ensure the accuracy and reliability of the calculation, we use bipolar method for its verification. The first standard Pt-Rh 10-platinum thermocouple is used to verify a K type Class II thermocouple, and the verification point is 1000℃. This paper mainly introduces the uncertainty evaluation of this verification method and the indication error.

  20. Assessment of the vibration on the foam legged and sheet metal-legged passenger seat

    Directory of Open Access Journals (Sweden)

    L. Dahil

    2015-10-01

    Full Text Available In this study, it was aim ed to decrease the vibration reaching to passenger from the legs of vehicle seats. In order to determine the levels of vibrations reaching at passengers, a test pad placed under the passenger seat was used, and HVM100 device was used for digitizing the information obtained. By transferring the vibration data to system by using HVM100 device, the acceleration graphics were prepared with Blaze software. As a result, it was determined that the acceleration values of seat legs made of foam material were lower than that of seat legs made of 2 mm thick sheet metal, so they damped the vibration better.

  1. Restless legs symptoms in a patient with above knee amputations: a case of phantom restless legs.

    Science.gov (United States)

    Hanna, Philip A; Kumar, Sanjeev; Walters, Arthur S

    2004-01-01

    We describe a 78-year-old gentleman who, following bilateral above-knee amputations, developed symptoms of restless legs syndrome in the absent portions of his lower extremities. These symptoms improved with dopamine agonist therapy. In addition, he later developed parkinsonism with prominent rest tremor on metoclopramide. This suggests that this individual had a dopamine-deficient state which predisposed him to both restless legs syndrome and drug-induced or drug-exacerbated parkinsonism. We propose expanding the spectrum of phantom limb phenomena to include phantom restless legs.

  2. [The influence of the leg load and the support mobility under leg on the anticipatory postural adjustment].

    Science.gov (United States)

    Kazennikov, O V; Kireeva, T B; Shlykov, V Iu

    2015-01-01

    Anticipatory postural adjustment is an essential part of equilibrium maintainance during standing in human. So changes in stance condition could affect both control of equilibrium and anticipatory adjustment. Anticipatory changes in the stabilogram of each leg were studied in standing subject during the early stage of quick right arm lifting while legs were on two separated supports. The center of pressure (CP) movement was analyzed in three variants of experiment: both legs on immovable support, with only right leg on the movable support and with only left leg on the moveable support. In each standing condition subject stood with symmetrical load on two legs or with the load voluntary transferred to one leg. The anticipatory CP shift depended on the mobility of the support under the leg and on loading of the leg. While standing on unmovable supports with symmetrical load on the legs before lifting of the right arm CP of right leg shifted backward and CP of left leg--forward. While standing with one leg on movable support the anticipatory CP shift of this leg was small and did not depend on the load on the leg. However the shift of CP of the leg that was placed on the unmovable support depended on the load in the same way as in the case when both legs were on unmovable supports. Results suggested that since on movable support the support and proprioceptive afferent flow from distal part of the leg that was did not supply unambiguous information about body position, the role of distal joints in posture control is reduced.

  3. Several Sources of Thermocouples Instability%热电偶不稳定性的几个来源

    Institute of Scientific and Technical Information of China (English)

    闻杰; 刘强

    2014-01-01

    Thermocouple is a common used sensor in industrial temperature measurement, which has characteristics of high accuracy, wide economy and temperature. However, during the measurement, the measurement results of thermocouple will have instability that caused by measurement conditions and environmental restrictions. For example: pollution, oxidation, reduction, physical condition, embrittlement, irradiation are the major sources.%热电偶是工业温度测量常用的传感器,它具有精度高、经济和温度宽的特点。然而在测量过程中热电偶也会因为测量条件和环境限制而导致出现测量结果的不稳定性。例如:污染、氧化、还原、物理条件、脆裂、照射就是影响热电偶测量结果不稳定性的主要来源。

  4. Comparisons of Co-C and Pd-C Eutectic-Point Cells for Thermocouple Calibration Between NMIA and NMIJ

    Science.gov (United States)

    Ogura, H.; Jahan, F.; Yamazawa, K.

    2017-02-01

    Comparisons between NMIA and NMIJ on the melting temperatures of the Co-C eutectic point and the Pd-C eutectic point were performed using an NMIJ high-temperature furnace. The eutectic-point cells were constructed by NMIA and NMIJ following two different specifications. NMIA designed two miniature crucibles, one for Co-C and one for Pd-C eutectic-point cells. NMIJ designed larger eutectic-point cells, one for Co-C and one for Pd-C eutectic-point cells. Prior to performing the comparisons, the effect of conductive heat flow through the thermocouple stem was evaluated during the melting. The comparisons of the Co-C eutectic-point cells and of the Pd-C eutectic-point cells were performed using types R, B and Pt/Pd thermocouples. Despite the different cell designs and different material sources, the melting temperatures of the Co-C and Pd-C eutectic-point cells under investigation agreed within 0.1°C.

  5. Surface thermocouples for measurement of pulsed heat flux in the divertor of the Alcator C-Mod tokamak.

    Science.gov (United States)

    Brunner, D; LaBombard, B

    2012-03-01

    A novel set of thermocouple sensors has been developed to measure heat fluxes arriving at divertor surfaces in the Alcator C-Mod tokamak, a magnetic confinement fusion experiment. These sensors operate in direct contact with the divertor plasma, which deposits heat fluxes in excess of ~10 MW/m(2) over an ~1 s pulse. Thermoelectric EMF signals are produced across a non-standard bimetallic junction: a 50 μm thick 74% tungsten-26% rhenium ribbon embedded in a 6.35 mm diameter molybdenum cylinder. The unique coaxial geometry of the sensor combined with its single-point electrical ground contact minimizes interference from the plasma/magnetic environment. Incident heat fluxes are inferred from surface temperature evolution via a 1D thermal heat transport model. For an incident heat flux of 10 MW/m(2), surface temperatures rise ~1000 °C/s, corresponding to a heat flux flowing along the local magnetic field of ~200 MW/m(2). Separate calorimeter sensors are used to independently confirm the derived heat fluxes by comparing total energies deposited during a plasma pulse. Langmuir probes in close proximity to the surface thermocouples are used to test plasma-sheath heat transmission theory and to identify potential sources of discrepancies among physical models.

  6. 工业炉上热电偶的不当使用%Improper Use of Thermocouple in Industrial Furnace

    Institute of Scientific and Technical Information of China (English)

    霍大勇; 胡应占

    2012-01-01

    通过6个生产现场故障实例,说明了工业炉上应用的热电偶不当使用引发的设备运行故障和生产事故.分析了事故产生的原因.指出了为了避免同类生产和设备事故应该采取的关于工业炉上热电偶的配置、运行、操作方式的12个要点以及相关的技术措施.%Through six failure examples at the production site, the equipment operation fault and production accidents caused by the improper use of thermocouple in the industrial furnace are illustrated. The formation causes of the accident are analyzed. Moreover, in order to avoid similar accident occurred, the 12 points and related technical measures of the configuration, operation, and operation method of thermocouple should take about industrial furnace are pointed out.

  7. Investigation of pool boiling dynamics on a rectangular heater using nano-thermocouples: is it chaotic or stochastic?

    Energy Technology Data Exchange (ETDEWEB)

    Sathyamurthi, Vijaykumar; Banerjee, Debjyoti [Texas A and M University, College Station, TX (United States). Dept. of Mechanical Engineering], e-mail: dbanerjee@tamu.edu

    2009-07-01

    The non-linear dynamical model of pool boiling on a horizontal rectangular heater is assessed from experimental results in this study. Pool boiling experiments are conducted over a horizontal rectangular silicon substrate measuring 63 mm x 35 mm with PF-5060 as the test fluid. Novel nano-thermocouples, micro-machined in-situ on the silicon substrate are used to measure the surface temperature fluctuations for steady state pool boiling. The acquisition frequency for temperature data from the nano-thermocouples is 1 k Hz. The surface temperature fluctuations are analyzed using the TISEAN{sup c} package. A time-delay embedding is employed to generate higher dimensional phase-space vectors from the temperature time series record. The optimal delay is determined from the first minimum of the mutual information function. Techniques such as recurrence plots, and false nearest neighbors tests are employed to assess the presence of deterministic chaotic dynamics. Chaos quantifiers such as correlation dimensions are found for various pool boiling regimes using the raw data as well as noise-reduced data. Additionally, pseudo-phase spaces are used to reconstruct the 'attractors'. The results after non-linear noise reduction shows definitive presence of low-dimensional (d {<=} 7) chaos in fully developed nucleate boiling, at critical heat flux and in film boiling. (author)

  8. COLD-WORKED HARDWARE

    Directory of Open Access Journals (Sweden)

    N. M. Strizhak

    2007-01-01

    Full Text Available The different types of cold-worked accessory are examined in the article. The necessity of development of such type of accessory in the Republic of Belarus due to requirements of market is shown. High emphasis is placed on the methods of increase of plasticity of cold-worked accessory from usual mill of RUP and CIS countries.

  9. Cold Sores (HSV-1)

    Science.gov (United States)

    ... A Week of Healthy Breakfasts Shyness Cold Sores (HSV-1) KidsHealth > For Teens > Cold Sores (HSV-1) A A A What's in this article? ... or around a person's lips, are caused by herpes simplex virus-1 (HSV-1) . But they don't ...

  10. Working in the Cold

    Centers for Disease Control (CDC) Podcasts

    2016-02-08

    During the winter, many workers are outdoors, working in cold, wet, icy, or snowy conditions. Learn how to identify symptoms that tell you there may be a problem and protect yourself from cold stress.  Created: 2/8/2016 by National Institute for Occupational Safety and Health (NIOSH).   Date Released: 2/8/2016.

  11. Cold fusion research

    Energy Technology Data Exchange (ETDEWEB)

    None

    1989-11-01

    I am pleased to forward to you the Final Report of the Cold Fusion Panel. This report reviews the current status of cold fusion and includes major chapters on Calorimetry and Excess Heat, Fusion Products and Materials Characterization. In addition, the report makes a number of conclusions and recommendations, as requested by the Secretary of Energy.

  12. Cold-Weather Sports

    Science.gov (United States)

    ... Surgery? A Week of Healthy Breakfasts Shyness Cold-Weather Sports KidsHealth > For Teens > Cold-Weather Sports A A A What's in this article? ... Equipment Ahh, winter! Shorter days. Frigid temperatures. Foul weather. What better time to be outdoors? Winter sports ...

  13. Coping with Colds

    Science.gov (United States)

    ... have heard that chicken soup can cure a cold. There's no real proof of this, but sick people have been swearing by it for more than 800 years. When Should I Go to the Doctor? Teens who catch colds usually don't get very sick or need ...

  14. Computer-assisted detection of nocturnal leg motor activity in patients with restless legs syndrome and periodic leg movements during sleep.

    Science.gov (United States)

    Ferri, Raffaele; Zucconi, Marco; Manconi, Mauro; Bruni, Oliviero; Miano, Silvia; Plazzi, Giuseppe; Ferini-Strambi, Luigi

    2005-08-01

    To assess the performance of a new method for automatic detection of periodic leg movements during sleep. Leg movements during sleep were visually detected in the tibialis anterior muscles recordings of 15 patients with restless legs syndrome and 15 normal controls. Leg movements were detected automatically by means of a new computer method with which electromyogram signals are first digitally band-pass filtered and then rectified; subsequently, the detection of leg movements is performed by using 2 thresholds: one for the starting point and another to detect the end point of each leg movement. Sensitivity and false-positive rate were obtained; the American Sleep Disorders Association parameters were also computed, and the results analyzed by means of the Kendall W coefficient, the linear correlation coefficient and the Bland-Altman plots. N/A. Fifteen patients with restless legs syndrome and periodic leg movements and 15 controls. High values of the Kendall W coefficient of concordance between automatic and visual analysis were found with values close to 1 and the linear correlation coefficient for leg movements index and total leg movements index was > 0.950 (p visual and computer detection, which were -9.01 and +9.89 for the periodic leg movement index. None of the normal controls was found to have periodic leg movement indexes >5 after automatic analysis. Our method can be applied to the clinical evaluation of periodic leg movements during sleep, with some caution in patients with a low periodic leg movement indexes. Large-scale research application is possible and can be considered as reliable.

  15. Top Ten Tiks Far Beautiful Legs

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    HERE experts provide women witha guide In better stocking buys. 1. Brightly-colored stockings suchas flaming red or pure blue suit only tall,slim ladies with elegant legs. 2. Opaque stockings, suit only slimlegs. 3. Dark or thinly striped stockings

  16. Clinical aspects of lower leg compartment syndrome

    NARCIS (Netherlands)

    Brand, Johan Gerard Henric van den

    2004-01-01

    A compartment syndrome is a condition in which increased pressure within a limited space compromises the circulation and function of tissues within that space. Although pathofysiology is roughly similar in chronic exertional and acute compartment syndrome of the lower leg, the clinical presentation

  17. Hereditary spherocytosis presenting as indolent leg ulcers

    Directory of Open Access Journals (Sweden)

    Muhammed K

    1997-01-01

    Full Text Available Indolent leg ulcertation, which is the rarest manifestation of hereditary spherocytosis, started at the age of 5 years affecting a 15-year-old boy and his mother is reported. Review of literature showed very few reports from India and abroad. The response to oral folic acid was excellent

  18. An automatic hinge system for leg orthoses

    NARCIS (Netherlands)

    Rietman, J.S.; Goudsmit, J.; Meulemans, D.; Halbertsma, J.P.K.; Geertzen, J.H.B.

    2004-01-01

    This paper describes a new, automatic hinge system for leg orthoses, which provides knee stability in stance, and allows knee-flexion during swing. Indications for the hinge system are a paresis or paralysis of the quadriceps muscles. Instrumented gait analysis was performed in three patients, fitte

  19. Mechanics of six-legged runners.

    Science.gov (United States)

    Full, R J; Tu, M S

    1990-01-01

    Six-legged pedestrians, cockroaches, use a running gait during locomotion. The gait was defined by measuring ground reaction forces and mechanical energy fluctuations of the center of mass in Blaberus discoidalis (Serville) as they travelled over a miniature force platform. These six-legged animals produce horizontal and vertical ground-reaction patterns of force similar to those found in two-, four- and eight-legged runners. Lateral forces were less than half the vertical force fluctuations. At speeds between 0.08 and 0.66 ms-1, horizontal kinetic and gravitational potential energy changes were in phase. This pattern of energy fluctuation characterizes the bouncing gaits used by other animals that run. Blaberus discoidalis attained a maximum sustainable stride frequency of 13 Hz at 0.35 ms-1, the same speed and frequency predicted for a mammal of the same mass. Despite differences in body form, the mass-specific energy used to move the center of mass a given distance (0.9 J kg-1m-1) was the same for cockroaches, ghost crabs, mammals, and birds. Similarities in force production, stride frequency and mechanical energy production during locomotion suggest that there may be common design constraints in terrestrial locomotion which scale with body mass and are relatively independent of body form, leg number and skeletal type.

  20. Well Leg Compartment Syndrome After Abdominal Surgery

    DEFF Research Database (Denmark)

    Christoffersen, Jens Krogh; Hove, Lars Dahlgaard; Mikkelsen, Kim Lyngby;

    2016-01-01

    BACKGROUND: Well leg compartment syndrome (WLCS) is a complication to abdominal surgery. We aimed to identify risk factors for and outcome of WLCS in Denmark and literature. METHODS: Prospectively collected claims to the Danish Patient Compensation Association (DPCA) concerning WLCS after abdominal...

  1. Leg og læring

    DEFF Research Database (Denmark)

    Pedersen, Annette

    2008-01-01

    Leg synes at have et potentiale som metode til at fremme læring. Men hvordan? Legen har en vis grad af parallelitet med den virkelige verden i dens interaktive og relationelle strukturer. Det bliver muligt at finde nye meninger i interaktioner, som refererer til vante interaktionsformer, men alli...

  2. A completely intramedullary leg lengthening device

    NARCIS (Netherlands)

    Aalsma, A.M.M.; Hekman, E.E.G.; Stapert, J.W.J.L.; Grootenboer, H.J.

    1998-01-01

    The procedure and the external fixator for lengthening long bones was developed by G.A. Ilizarov in the late 1960's. This technique has, despite its proven abilities for leg lengthening and correction of angular deformities, some considerable disadvantages for patients. Discomfort, infections and re

  3. Clinical aspects of lower leg compartment syndrome

    NARCIS (Netherlands)

    Brand, Johan Gerard Henric van den

    2004-01-01

    A compartment syndrome is a condition in which increased pressure within a limited space compromises the circulation and function of tissues within that space. Although pathofysiology is roughly similar in chronic exertional and acute compartment syndrome of the lower leg, the clinical

  4. Superficial warming and cooling of the leg affects walking speed and neuromuscular impairments in people with spastic paraparesis.

    Science.gov (United States)

    Denton, A; Bunn, L; Hough, A; Bugmann, G; Marsden, J

    2016-12-01

    People with hereditary and spontaneous spastic paraparesis (HSSP) report that their legs are stiffer and walking is slower when their legs are cold. This study explored the effects of prolonged superficial cooling and warming of the lower leg on walking speed and local measures of neuromuscular impairments. This was a randomised pre- and post-intervention study of 22 HSSP participants and 19 matched healthy controls. On 2 separate occasions, one lower leg was cooled or warmed. Measurements included walking speed and measures of lower limb impairment: ankle movement, passive muscle stiffness, spasticity (stretch reflex size), amplitude and rate of force generation in dorsi- and plantarflexors and central and peripheral nerve conduction time/velocity. For both participants and controls, cooling decreased walking speed, especially for HSSP participants. For both groups, cooling decreased the dorsiflexor rate and amplitude of force generation and peripheral nerve conduction velocity and increased spasticity. Warming increased dorsiflexor rate of force generation and nerve conduction velocity and decreased spasticity. Superficial cooling significantly reduced walking speed for people with HSSP. Temperature changes were associated with changes in neuromuscular impairments for both people with spastic paraparesis and controls. This study does not support the use of localised cooling in rehabilitation for people with spastic paraparesis as reported in other neurological conditions. Rehabilitation interventions that help prevent heat loss (insulation) or improve limb temperature via passive or active means, particularly when the legs and/or environment are cool, may benefit people with spastic paraparesis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. How Cold is Cold Dark Matter?

    CERN Document Server

    Armendariz-Picon, Cristian

    2013-01-01

    If cold dark matter consists of particles, these must be non-interacting and non-relativistic by definition. In most cold dark matter models, however, dark matter particles inherit a non-vanishing velocity dispersion from interactions in the early universe, a velocity that redshifts with cosmic expansion but certainly remains non-zero. In this article, we place model-independent constraints on the dark matter temperature to mass ratio, whose square root determines the dark matter velocity dispersion. We only assume that dark matter particles decoupled kinetically while non-relativistic, when galactic scales had not entered the horizon yet, and that their momentum distribution has been Maxwellian since that time. Under these assumptions, using cosmic microwave background and matter power spectrum observations, we place upper limits on the temperature to mass ratio of cold dark matter. The latter imply that its velocity dispersion extrapolated to the present has to be smaller than 56 m/s. Cold dark matter has t...

  6. 热电偶测温原理及在石灰窑中的应用%Temperature measuring principle of thermocouple and its application in lime kiln

    Institute of Scientific and Technical Information of China (English)

    王向创; 宾鸿伟; 马金华

    2012-01-01

    The working principle of thermocouple and its varieties and features are described. The error factors generated in the application of thermocouple in lime kiln and matters needing attention are narrated. It is emphasized that the application of thermocouple in the process of the production of high quality lime has an important effect.%介绍了热电偶工作原理及其种类特点;阐述了热电偶在石灰窑中使用时所产生的误差因素和注意事项;强调了热电偶在生产优质石灰的过程中具有重要作用。

  7. A colored leg banding technique for Amazona parrots

    Science.gov (United States)

    Meyers, J.M.

    1995-01-01

    A technique for individual identification of Amazona was developed using plastic leg bands. Bands were made from 5- and 7-mm-wide strips of laminated PVC coiled 2.5 times with an inside diameter 4-5 mm gt the maximum diameter of the parrot's leg. Seventeen parrots were captured in Puerto Rico, marked with individual plastic leg bands, and observed for 204-658 d with only one lost or damaged plastic band. Plastic leg bands did not cause injury to or calluses on parrots' legs. The plastic material used for making leg bands was available in 18 colors in 1994, which would allow unique marking of 306 individuals using one plastic leg band on each leg.

  8. Limb oxygenation during the cold pressor test in spinal cord-injured humans.

    Science.gov (United States)

    Ogata, Hisayoshi; Hobara, Hiroaki; Uematsu, Azusa; Ogata, Toru

    2012-04-01

    To investigate changes in tissue oxygenation in the arm and leg during the cold pressor test in humans with spinal cord injury (SCI). Subjects with SCI at cervical 6 (n=7) and subjects with SCI at thoracic 5 or thoracic 6 (n=5) experienced 3-min cold water immersion of the foot and subsequent 10-min recovery. Changes in tissue oxygenation and blood pressure were determined. Tissue oxygenation was assessed by hemoglobin/myoglobin concentration (Hb/MbO2) measured using near-infrared spectroscopy. Mean arterial blood pressures increased significantly by 15±9 and 6±6 mmHg during cold water immersion in the cervical and thoracic SCI groups, respectively (Pcontrol of arm oxygenation and leg oxygenation in the region below SCI.

  9. The comparison of cold-water immersion and cold air therapy on maximal cycling performance and recovery markers following strength exercises

    Directory of Open Access Journals (Sweden)

    Kane J. Hayter

    2016-03-01

    Full Text Available This study examined the effects of cold-water immersion (CWI and cold air therapy (CAT on maximal cycling performance (i.e. anaerobic power and markers of muscle damage following a strength training session. Twenty endurance-trained but strength-untrained male (n = 10 and female (n = 10 participants were randomised into either: CWI (15 min in 14 °C water to iliac crest or CAT (15 min in 14 °C air immediately following strength training (i.e. 3 sets of leg press, leg extensions and leg curls at 6 repetition maximum, respectively. Creatine kinase, muscle soreness and fatigue, isometric knee extensor and flexor torque and cycling anaerobic power were measured prior to, immediately after and at 24 (T24, 48 (T48 and 72 (T72 h post-strength exercises. No significant differences were found between treatments for any of the measured variables (p > 0.05. However, trends suggested recovery was greater in CWI than CAT for cycling anaerobic power at T24 (10% ± 2%, ES = 0.90, T48 (8% ± 2%, ES = 0.64 and T72 (8% ± 7%, ES = 0.76. The findings suggest the combination of hydrostatic pressure and cold temperature may be favourable for recovery from strength training rather than cold temperature alone.

  10. How to Treat Restless Leg Syndrome with Traditional Chinese Medicine?

    Institute of Scientific and Technical Information of China (English)

    林宗广

    2003-01-01

    @@ In clinic, restless leg syndrome manifests to have thesymptoms of unbearable soreness, numbness,insect-crawling like itching and electric-shock likeburning sensation in the deep muscles of both legs,which generally appear symmetrically, or severer inone leg, and attack mostly in the night before sleep,but rarely in the day time.

  11. Leg intravenous pressure during head-up tilt.

    NARCIS (Netherlands)

    Groothuis, J.T.; Poelkens, F.; Wouters, C.W.; Kooijman, M.; Hopman, M.T.E.

    2008-01-01

    Leg vascular resistance is calculated as the arterial-venous pressure gradient divided by blood flow. During orthostatic challenges it is assumed that the hydrostatic pressure contributes equally to leg arterial, as well as to leg venous pressure. Because of venous valves, one may question whether,

  12. Lower leg electrical impedance after distal bypass surgery

    DEFF Research Database (Denmark)

    Belanger, G K; Bolbjerg, M L; Heegaard, N H;

    1998-01-01

    Electrical impedance was determined in 13 patients following distal bypass surgery to evaluate lower leg oedema as reflected by its circumference. Tissue injury was assessed by the plasma concentration of muscle enzymes. After surgery, the volume of the control lower leg increased from 1250 (816...... to be a useful method for the evaluation of lower leg oedema after distal bypass surgery....

  13. Protection against high intravascular pressure in giraffe legs

    DEFF Research Database (Denmark)

    Petersen, Karin K; Hørlyck, Arne; Østergaard, Kristine Hovkjær

    2013-01-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination...

  14. One-dimensional linear calculation of the heat flux from infrared and thermocouple measurements at Jet tokamak; Calcul 1D lineaire du flux de chaleur par inversion des mesures de temperatures infrarouges et des thermocouples du Tokamak Jet

    Energy Technology Data Exchange (ETDEWEB)

    Poyet, M

    2005-07-01

    Our work is dedicated to the assessment of the heat released in the Jet tokamak divertor tiles. We have performed the computation of the heat flux from temperature data collected by thermo-couples through a 1 dimensional linear model. This method has implied solving an inverse problem whose matrix is singular, we have succeeded in using Tikhonov's regularization technique. Then we have compared these values of the heat flux with those deduced from infra-red measurements. Infra-red measurements are impaired by the deposition of particles on the surface. Both methods give unrealistic negative values at the end of the plasma discharge. The use of a non-linear 1-dimensional model that would allow the diffusion coefficient to vary is expected to improve the calculation. (A.C.)

  15. Initial characterization of the Cornell Cold Neutron Source

    Science.gov (United States)

    Spern, Stuart Alan

    1998-06-01

    A device to moderate reactor spectrum neutrons to subthermal energies and filter out photons and higher energy neutrons has been designed, constructed and tested at Ward Laboratory, Cornell University. The Cornell Cold Neutron Source, which houses a chamber containing an organic moderator (mesitylene), the cryogenic cooling apparatus, and the first three one-meter long neutron guide elements, is physically inserted into a beamport in the reactor biological shield. The remaining 10 guide elements, which act as the filter, are mounted on a horizontal I-beam, and surrounded with suitable radiation shielding. The elements are horizontally displaced from the beamport axis in a combination curved/straight layout to eliminate directly transmitted radiation. The guide penetrates the reactor bay wall, terminating in a dedicated room to provide a location for low background experiments. Out-of-reactor bench thermal tests were conducted on the cryorefrigerator itself, then on a shortened version of the cryogenic cooling apparatus, and finally on the full scale system using heaters to simulate reactor induced nuclear heating in upstream cryogenic components. Temperature results, measured by silicon diodes, were close to predicted values. In-reactor tests were conducted to benchmark thermal performance, and to ascertain reliability of temperature and flux measurement systems. Type E thermocouples were selected for temperature measurement in the hostile reactor environment; although they depart from standard output at cryogenic temperatures due to inhomogeneities in the wire, crucial thermocouples located on the moderator chamber are calibrated against the in situ gas thermometer formed with the chamber as the sense bulb and a canister of known volume as the gas reservoir. In- reactor trials demonstrated reproducibility of thermocouple results. Moderator temperatures of 11 K at zero reactor power up to 28.5 K at 500 kW were obtained. Time-of-flight measurements were taken at 10

  16. Single Phase Online UPS Design Using Three Leg Converters

    Directory of Open Access Journals (Sweden)

    R. Ramesh,

    2014-03-01

    Full Text Available The single phase online UPS integrate with the three leg type converter which operate with battery charger and the inverter. The first leg controls the ability of charging battery. The third leg controls the output voltage. The common leg is used to control the line frequency. The battery charger has the ability of making the correction of power factor during the battery charging. The inverter is used to maintain the output voltage and to limit the output current. The main feature of the three leg converter is used to reduce the number of switching devices. So that the system has the low value of power loss and low cost.

  17. Cold Vacuum Drying Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the K-Basins (see K-Basins link) in Hanford's 100 Area is a facility called the Cold Vacuum Drying Facility (CVDF).Between 2000 and 2004, workers at the...

  18. Cold-induced metabolism

    NARCIS (Netherlands)

    Lichtenbelt, W. van Marken; Daanen, H.A.M.

    2003-01-01

    Purpose of review Cold response can be insulative (drop in peripheral temperature) or metabolic (increase in energy expenditure). Nonshivering thermogenesis by sympathetic, norepinephrine-induced mitochondrial heat production in brown adipose tissue is a well known component of this metabolic

  19. The cold reading technique.

    Science.gov (United States)

    Dutton, D L

    1988-04-15

    For many people, belief in the paranormal derives from personal experience of face-to-face interviews with astrologers, palm readers, aura and Tarot readers, and spirit mediums. These encounters typically involve cold reading, a process in which a reader makes calculated guesses about a client's background and problems and, depending on the reaction, elaborates a reading which seems to the client so uniquely appropriate that it carries with it the illusion of having been produced by paranormal means. The cold reading process is shown to depend initially on the Barnum effect, the tendency for people to embrace generalized personality descriptions as idiosyncratically their own. Psychological research into the Barnum effect is critically reviewed, and uses of the effect by a professional magician are described. This is followed by detailed analysis of the cold reading performances of a spirit medium. Future research should investigate the degree to which cold readers may have convinced themselves that they actually possess psychic or paranormal abilities.

  20. A Cold Alarm

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Since the end of 2009, north China has been repeatedly struck by arctic-like blasts of cold weather. As temperatures have plummeted to historic lows, they have inflicted considerable suffering as well.

  1. A Cold Alarm

    Institute of Scientific and Technical Information of China (English)

    ZHOU JIANXIONG

    2010-01-01

    @@ Since the end of 2009, north China has been repeatedly struck by arctic-like blasts of cold weather. As temperatures have plummeted to historic lows, they have inflicted considerable suffering as well.

  2. Multi-leg heat pipe evaporator

    Science.gov (United States)

    Alario, J. P.; Haslett, R. A. (Inventor)

    1986-01-01

    A multileg heat pipe evaporator facilitates the use and application of a monogroove heat pipe by providing an evaporation section which is compact in area and structurally more compatible with certain heat exchangers or heat input apparatus. The evaporation section of a monogroove heat pipe is formed by a series of parallel legs having a liquid and a vapor channel and a communicating capillary slot therebetween. The liquid and vapor channels and interconnecting capillary slots of the evaporating section are connected to the condensing section of the heat pipe by a manifold connecting liquid and vapor channels of the parallel evaporation section legs with the corresponding liquid and vapor channels of the condensing section.

  3. Clinical quality indicators of venous leg ulcers

    DEFF Research Database (Denmark)

    Kjaer, Monica L; Mainz, Jan; Soernsen, Lars T

    2005-01-01

    and reliable evidence-based quality indicators of venous leg ulcer care. A Scandinavian multidisciplinary, cross-sectional panel of wound healing experts developed clinical quality indicators on the basis of scientific evidence from the literature and subsequent group nominal consensus of the panel......%) were assessed for venous surgery. Distal arterial pressure was measured following initial examination in 33 of the patients (34%). All patients (100%) were prescribed compression therapy. Of the 98 patients, 11 (11%) had ulcers recur in 3 months and 72 (73%) healed in 12 months, which is in line......; an independent medical doctor tested the feasibility and reliability of these clinical indicators, assessing the quality of medical technical care on 100 consecutive venous leg ulcer patients. Main outcome measures were healing, recurrence, pain, venous disease diagnosis, differential diagnosis and treatment...

  4. Multi-leg heat pipe evaporator

    Science.gov (United States)

    Alario, J. P.; Haslett, R. A.

    1986-04-01

    A multileg heat pipe evaporator facilitates the use and application of a monogroove heat pipe by providing an evaporation section which is compact in area and structurally more compatible with certain heat exchangers or heat input apparatus. The evaporation section of a monogroove heat pipe is formed by a series of parallel legs having a liquid and a vapor channel and a communicating capillary slot therebetween. The liquid and vapor channels and interconnecting capillary slots of the evaporating section are connected to the condensing section of the heat pipe by a manifold connecting liquid and vapor channels of the parallel evaporation section legs with the corresponding liquid and vapor channels of the condensing section.

  5. High-temperature thermocouple and heat flux gauge using a unique thin film-hardware hot junction

    Science.gov (United States)

    Liebert, C. H.; Holanda, R.; Hippensteele, S. A.; Andracchio, C. A.

    1985-01-01

    A special thin film-hardware material thermocouple (TC) and heat flux gauge concept for a reasonably high temperature and high flux flat plate heat transfer experiment was fabricated and tested to gauge temperatures of 911 K. This concept was developed for minimal disturbance of boundary layer temperature and flow over the plates and minimal disturbance of heat flux through the plates. Comparison of special heat flux gauge Stanton number output at steady-state conditions with benchmark literature data was good and agreement was within a calculated uncertainty of the measurement system. Also, good agreement of special TC and standard TC outputs was obtained and the results are encouraging. Oxidation of thin film thermoelements was a primary failure mode after about 5 of operation.

  6. Recovery and radiation corrections and time constants of several sizes of shielded and unshielded thermocouple probes for measuring gas temperature

    Science.gov (United States)

    Glawe, G. E.; Holanda, R.; Krause, L. N.

    1978-01-01

    Performance characteristics were experimentally determined for several sizes of a shielded and unshielded thermocouple probe design. The probes are of swaged construction and were made of type K wire with a stainless steel sheath and shield and MgO insulation. The wire sizes ranged from 0.03- to 1.02-mm diameter for the unshielded design and from 0.16- to 0.81-mm diameter for the shielded design. The probes were tested through a Mach number range of 0.2 to 0.9, through a temperature range of room ambient to 1420 K, and through a total-pressure range of 0.03 to 0.2.2 MPa (0.3 to 22 atm). Tables and graphs are presented to aid in selecting a particular type and size. Recovery corrections, radiation corrections, and time constants were determined.

  7. Pharmacologic treatment of venous leg ulcers.

    Science.gov (United States)

    Dormandy, J A

    1995-01-01

    In terms of prevalence, total cost and morbidity, venous leg ulcers are probably by far the most important type of ulcerations in the leg. The macrocirculatory defect leading to a raised ambulatory venous pressure is now accepted as a common initial pathologic pathway. Most current treatment modalities, such as surgery or external compression, are designed to control the macrovascular defect. However, it is the microcirculatory consequences of the venous hypertension that give rise to the trophic skin changes and ultimately to ulceration. At this microcirculatory level, pharmacotherapy may be a useful adjunct in the treatment of venous leg ulcers. The microcirculatory pathophysiologic changes include decreased fibrinolytic activity, elevated plasma fibrinogen, microcirculatory thrombi, and inappropriate activation of the white blood cells. The oxidative burst from the activated white cells probably plays a key role by releasing locally leukocyte-derived free radicals, proteolytic enzymes, cytokines, platelet-activating factor, and a number of other noxious mediators. An important additional component in recalcitrant venous ulcers is co-existing arterial disease, which is probably present in 15-20% of cases. Decreased arterial perfusion pressure will further aggravate the ischemic changes caused by the venous hypertension. Pentoxifylline downregulates leukocyte activation, reduces leukocyte adhesion, and also has fibrinolytic effects. A number of clinical studies have therefore been carried out to examine the clinical efficacy of pentoxifylline in treatment of venous leg ulcers. Probably the largest published placebo-controlled, double-blind randomized study was reported in 1990. In this study, 80 patients received either pentoxifylline 400 mg three times a day orally or matching placebo for 6 months or until their reference ulcer healed if this occurred sooner. Complete healing of the reference ulcer occurred in 23 of the 38 patients treated with pentoxifylline

  8. Restless Legs Syndrome and Psychiatric Disorders.

    Science.gov (United States)

    Mackie, Susan; Winkelman, John W

    2015-09-01

    There are strong epidemiologic ties between restless legs syndrome (RLS) and a wide array of psychiatric conditions. Although the mechanism of this association is not fully understood, there are likely bidirectional cause-and-effect relationships. Appreciation of psychiatric comorbidity is an essential component of the treatment of RLS. Clinicians should be prepared to facilitate appropriate psychiatric treatment and consider the complex interactions between psychiatric medications, RLS medications, and the clinical course of both illnesses.

  9. Visual based localization for a Legged Robot

    OpenAIRE

    Martín Rico, Francisco; Matellán Olivera, Vicente; González-Careaga, Rafaela; Barrera González, Pablo; Cañas, José María

    2006-01-01

    P. 708-715 This paper presents a visual based localization mechanism for a legged robot. Our proposal, fundamented on a probabilistic approach, uses a precompiled topological map where natural landmarks like doors or ceiling lights are recognized by the robot using its on-board camera. Experiments have been conducted using the AIBO Sony robotic dog showing that it is able to deal with noisy sensors like vision and to approximate world models representing indoor of c...

  10. Vision based behaviors for a legged robot

    OpenAIRE

    Ruiz, Juan V.; Montero, Pablo; Martín Rico, Francisco; Matellán Olivera, Vicente

    2005-01-01

    This article describes two vision-based behaviors designed for an autonomous legged robot. These behaviors have been designed in a modular way in order to be able to integrate them in an architecture named DSH (Dynamic Schema Hierarchies), which is also briefly described. These behaviors have been tested in office indoor environments and experiments carried out are also described in this paper. The platform used in these experiments carried out are also described in theis paper. The platform ...

  11. Leg contracture in mice: an assay of normal tissue response

    Energy Technology Data Exchange (ETDEWEB)

    Stone, H.B.

    1984-07-01

    Leg contracture, defined as the difference in extensibility of the control and irradiated hind legs of mice, was found to correlate with single doses of radiation from about 20 to 80 Gy. The time of development of the early phase of the response coincided with that reported for the appearance of the acute skin response, and in some cases, partially reversed as this reaction healed. The contracture then progressed again at a moderate rate through 90 days, and then more slowly through one year. Skin contraction, measured by decrease in intertattoo distance, was assayed in the same mice. It followed the same time course as leg contracture, but had a different dose-response relationship. To determine the contribution of skin contraction to the overall leg contracture response, mice were sacrificed and the leg contracture measured before and after the removal of the skin of the leg. After doses of up to 30 Gy, little contracture remained from skinning the leg, indicating that skin contraction was largely responsible for leg contracture in this dose range. After doses of about 45 Gy and above, some contracture remained in the skinned legs, although less than in intact legs. There was little or no enhancement of either skin contraction or leg contracture by the hypoxic cell sensitizers metronidazole or misonidazole.

  12. Legged-locomotion on inclined granular media

    Science.gov (United States)

    Rieser, Jennifer; Qian, Feifei; Goldman, Daniel

    Animals traverse a wide variety of complex environments, including situations in which the ground beneath them can yield (e.g. dry granular media in desert dunes). Locomotion strategies that are effective on level granular media can fail when traversing a granular slope. Taking inspiration from successful legged-locomotors in sandy, uneven settings, we explore the ability of a small (15 cm long, 100 g), six-c-shaped legged robot to run uphill in a bed of 1-mm-diameter poppy seeds, using an alternating tripod gait. Our fully automated experiments reveal that locomotor performance can depend sensitively on both environmental parameters such as the inclination angle and volume fraction of the substrate, and robot morphology and control parameters like leg shape, step frequency, and the friction between the feet of the robot and the substrate. We assess performance by measuring the average speed of the robot, and we find that the robot tends to perform better at higher step frequency and lower inclination angles, and that average speed decreases more rapidly with increasing angle for higher step frequency.

  13. Proprioceptive Actuation Design for Dynamic Legged locomotion

    Science.gov (United States)

    Kim, Sangbae; Wensing, Patrick; Biomimetic Robotics Lab Team

    Designing an actuator system for highly-dynamic legged locomotion exhibited by animals has been one of the grand challenges in robotics research. Conventional actuators designed for manufacturing applications have difficulty satisfying challenging requirements for high-speed locomotion, such as the need for high torque density and the ability to manage dynamic physical interactions. It is critical to introduce a new actuator design paradigm and provide guidelines for its incorporation in future mobile robots for research and industry. To this end, we suggest a paradigm called proprioceptive actuation, which enables highly- dynamic operation in legged machines. Proprioceptive actuation uses collocated force control at the joints to effectively control contact interactions at the feet under dynamic conditions. In the realm of legged machines, this paradigm provides a unique combination of high torque density, high-bandwidth force control, and the ability to mitigate impacts through backdrivability. Results show that the proposed design provides an impact mitigation factor that is comparable to other quadruped designs with series springs to handle impact. The paradigm is shown to enable the MIT Cheetah to manage the application of contact forces during dynamic bounding, with results given down to contact times of 85ms and peak forces over 450N. As a result, the MIT Cheetah achieves high-speed 3D running up to 13mph and jumping over an 18-inch high obstacle. The project is sponsored by DARPA M3 program.

  14. Aloe Vera and Infected Leg Ulcers

    Directory of Open Access Journals (Sweden)

    Asima Banu

    2012-06-01

    Full Text Available Background Infected leg ulcers are major health problems resulting in morbidity and disability and are usually chronic and refractory to antimicrobial treatment. Aims The present study is aimed at determining the bacteria involved in leg ulcers and their resistance patterns to commonly used antibiotics as well as to determine whether Aloe Vera has antibacterial activity against multi-drug resistant organisms and promotes wound healing. Method A total of 30 cases with leg ulcers infected with multi-drug resistant organisms were treated with topical aloe vera gel and 30 age and sex-matched controls were treated with topical antibiotics. Culture and sensitivity was done from the wounds on alternate days and the ulcer was clinically and microbiologically assessed after 10 days. The results were compiled and statistically analysed. Results Cultures of the study group who were using aloe vera dressings showed no growth by the fifth day in 10 (33.3% cases, seventh day in another 16 (53.3% and ninth day in two of the remaining four cases (6.7% while in two (6.7% cases there was no decrease in the bacterial count. This means that of the 30 cases, 28 showed no growth by the end of 11 days while two cases showed no decrease in bacterial count. Growth of bacteria in study group is decreased from 100% (30 cases to 6.7% (2 cases by day 11 with P

  15. Leg edema from intrathecal opiate infusions.

    Science.gov (United States)

    Aldrete, J A; Couto da Silva JM

    2000-01-01

    Despite the increasing popularity of intrathecal infusions to treat patients with long-term non-cancer-related pain, this therapy is not without serious side-effects. Five out of 23 patients who had intrathecal infusions of opiates for longer than 24 months developed leg and feet edema. As predisposing factors, cardiovascular disease, deep venous thrombosis, peripheral vascular disease, and venous stasis of the lower extremities were considered. Every patient who developed pedal and leg edema after the implantation of an infusion pump was also found to have leg edema and venous stasis prior to the time when the pump was inserted. This complication was severe enough to limit their physical activity, and to produce lymphedema, ulcerations and hyperpigmentation of the skin. Reduction of the edema occurred when the dose of the opiate was decreased, and in two cases in which the infusion was discontinued, there was almost complete resolution of the syndrome. It appears that the pre-existence of pedal edema and of venous stasis is a relative contraindication to the long-term intrathecal infusion of opiates in patients with chronic non-cancer pain. Copyright 2000 European Federation of Chapters of the International Association for the Study of Pain.

  16. Statistical Analysis of Hie (Cold Sensation and Hiesho (Cold Disorder in Kampo Clinic

    Directory of Open Access Journals (Sweden)

    Tetsuhiro Yoshino

    2013-01-01

    Full Text Available A cold sensation (hie is common in Japanese women and is an important treatment target in Kampo medicine. Physicians diagnose patients as having hiesho (cold disorder when hie disturbs their daily activity. However, differences between hie and hiesho in men and women are not well described. Hie can be of three types depending on body part where patients feel hie. We aimed to clarify the characteristics of patients with hie and hiesho by analyzing data from new patients seen at the Kampo Clinic at Keio University Hospital between 2008 and 2013. We collected information about patients’ subjective symptoms and their severity using visual analogue scales. Of 4,016 new patients, 2,344 complained about hie and 524 of those were diagnosed with hiesho. Hie was most common in legs/feet and combined with hands or lower back, rather than the whole body. Almost 30% of patients with hie felt upper body heat symptoms like hot flushes. Cold sensation was stronger in hiesho than non-hiesho patients. Patients with hie had more complaints. Men with hiesho had the same distribution of hie and had symptoms similar to women. The results of our study may increase awareness of hiesho and help doctors treat hie and other symptoms.

  17. Do anti-embolism stockings fit our legs? Leg survey and data analysis.

    Science.gov (United States)

    Macintyre, Lisa; Kent, Kimberly; McPhee, Donna

    2013-07-01

    Anti-embolism stockings are commonly used worldwide to prevent the development of thrombosis in hospitalised patients. Patients are typically measured for, and fitted with, anti-embolism stockings during extended periods of non-ambulation. Anti-embolism stockings must critically fit the leg to achieve optimum blood flow and thus success of prophylaxis. Therefore, hospitals endeavour to maintain stock of anti-embolism stockings that fit the majority of their patients. The objective of this study was to establish whether popular styles/brands of anti-embolism stockings "fitted" the legs of convenience sampled volunteers. Volunteer's legs were measured at ankle, calf and thigh following guidance from British nurses and in accordance with brand instructions. Leg measurements were subsequently compared to the size charts of 10 anti-embolism stocking styles made by 4 different manufacturers. "Fit" is defined as a volunteer's leg measurements matching any stocking size in a range at all measurement points. Volunteers were measured in different settings around Scotland, including private homes, work places and shopping centres. A convenience sample of 471 volunteers (283 female, 188 male) were recruited on the basis of willingness to participate and being over 16 years old. Volunteers ranged from 17 years to 82 years old with an average age of 35. The 10 different styles of anti-embolism stockings, made by 4 different brands, examined for this paper had a size match coefficient ranging from 0% to 100% for our volunteer's legs. The size match coefficient is strongly influenced by the Brand's sizing policy. The proportion of legs that "fit" a particular brand of anti-embolism stockings can be increased through: (1) the reduction of the number of leg measurement points that need to be matched to the size chart of the stockings; (2) the use of open-ended size ranges; (3) the use of increased size range width and (4) the use of increased overlap between sizes. However, all but

  18. AMS2750D《高温测量》规范对热电偶的规定%Requirements of thermocouple in AMS2750D《Pyrometry》

    Institute of Scientific and Technical Information of China (English)

    周淑梅; 国林芳

    2012-01-01

      It describes related requirements of thermocouple composition, calibration and usage in AMS2750D《Pyrometry》.%  介绍了AMS2750D《高温测量》规范对热电偶的组成、校验及使用的相关要求

  19. 铠装热电偶绝缘电阻的分析与改进%The analysis and improvement of the insulation resistance of the armorded thermocouple

    Institute of Scientific and Technical Information of China (English)

    秦彩霞; 翟小英; 牛晓利

    2014-01-01

    The insulation resistance is one of the technical data of the temperature instrument armorded thermocouple, it has two units MΩ.m and MΩ. The measure element of the armorded thermocouple is the armorded cable, the insulation resistance of the armorded thermocouple is related to the insulation resistance of the armorded cable. The capability index of the armorded cable decide directly the technique index of the armorded thermocouple.%绝缘电阻是温度仪表铠装热电偶的技术参数之一,单位有MΩ.m 和MΩ两种。铠装热电偶产品因为使用铠装热电偶电缆,产品绝缘电阻的检测值与测温元件铠装电缆的绝缘电阻值密切相关,铠装热电偶电缆的性能指标直接决定铠装热电偶产品绝缘电阻技术指标。

  20. Thermocouple mathematical model research based on PID neural network%基于PID神经网络的热电偶数学模型研究

    Institute of Scientific and Technical Information of China (English)

    徐宏宇; 朱永丽

    2011-01-01

    为提高热电偶的测温精度,首先介绍了热电偶测温数据处理的一般情况,在总结对比现有方法的优缺点基础上,对如何选取热电偶标定点的问题进行研究。设计了实际多路电偶数据采集电路,并对采集的数据进行了分析处理,运用PID神经网络建立热电偶的数学模型。通过实验验证,这种方法的测温精度较高,能满足实际对宽范围高精度的温度测量需要。%In order to improve the measurement precision of thermocouple,at first the general temperature data processing procedure which stems from the thermocouple is introduced.On the base of summing up exsiting methods,the problem is studied on how to select the special points of thermocouple.And a system is designed to collecting multichannel temperature data.By means of analysing the data,the mathematical model of thermocouple is founded.Proved by experiments,this method increases the temperature measurement precision and fits to actual request,which is wide rang with high pricise.

  1. Effect of Renal Transplantation in Restless Legs Syndrome.

    Science.gov (United States)

    Kahvecioglu, Serdar; Yildiz, Demet; Buyukkoyuncu, Nilufer; Celik, Huseyin; Tufan, Fatih; Kılıç, Ahmet Kasım; Gul, Bulent; Yildiz, Abdulmecid

    2016-02-01

    Restless legs syndrome is a disorder in which patients have irresistible urge to move legs during rest. Restless legs syndrome seems to be common in end-stage renal disease. After a successful renal transplant, symptoms ameliorate with renal function improvement and restless legs syndrome is seen less in this population. Here, we aimed to investigate restless legs syndrome frequency and associated factors in renal transplant patients. In a cross-sectional study with 193 patients (116 hemodialysis patients, 45 transplant patients, and 32 controls), the presence of restless legs syndrome was assessed using the Restless Legs Syndrome Questionnaire. Medical history, demographic, and laboratory data were collected from the patients' medical records. Patients were questioned about the presence of restless legs syndrome using the Restless Legs Syndrome Questionnaire. Patients were evaluated with Beck Depression Scale for depression and Pittsburgh tests for sleep disturbances. While the rate of restless legs syndrome was similar between transplants and controls, it was significantly greater in hemodialysis patients. Hemodialysis patients and controls had similar depression scores that were higher compared with transplant patients. Pittsburgh score was similar in transplant patients and controls and significantly increased in the hemodialysis patients. The rate of insomnia was significantly higher in the hemodialysis patients compared with the other 2 groups. Logistic regression analysis revealed independent correlates of restless legs syndrome as insomnia, Beck depression score, and being on hemodialysis. Linear regression analysis showed that independent correlates of higher Pittsburgh score were higher depression score, higher age, and presence of restless legs syndrome. The prevalence of restless legs syndrome is significantly lower in transplant patients than it is in patients on maintenance dialysis. In renal transplant patients, restless legs syndrome frequency was

  2. What's new: Management of venous leg ulcers: Approach to venous leg ulcers.

    Science.gov (United States)

    Alavi, Afsaneh; Sibbald, R Gary; Phillips, Tania J; Miller, O Fred; Margolis, David J; Marston, William; Woo, Kevin; Romanelli, Marco; Kirsner, Robert S

    2016-04-01

    Leg ulcerations are a common problem, with an estimated prevalence of 1% to 2% in the adult population. Venous leg ulcers are primarily treated in outpatient settings and often are managed by dermatologists. Recent advances in the diagnosis and treatment of leg ulcers combined with available evidence-based data will provide an update on this topic. A systematized approach and the judicious use of expensive advanced therapeutics are critical. Specialized arterial and venous studies are most commonly noninvasive. The ankle brachial pressure index can be performed with a handheld Doppler unit at the bedside by most clinicians. The vascular laboratory results and duplex Doppler findings are used to identify segmental defects and potential operative candidates. Studies of the venous system can also predict a subset of patients who may benefit from surgery. Successful leg ulcer management requires an interdisciplinary team to make the correct diagnosis, assess the vascular supply, and identify other modifiable factors to optimize healing. The aim of this continuing medical education article is to provide an update on the management of venous leg ulcers. Part I is focused on the approach to venous ulcer diagnostic testing.

  3. LEG CONQUASATION CAUSED BY PETROL TILLER WITH OPEN LOWER LEG FRACTURE

    Directory of Open Access Journals (Sweden)

    Ivan Golubović

    2014-03-01

    Full Text Available We present a 71-year old patient admitted to Plastic and Reconstructive Surgery Clinic, Clinical Center Niš for the right leg conquasation. The patient was injured accidentally by a petrol tiller. On admission, both thigh and lower leg conquasation was observed with large wound on anteromedial thigh and one on medial side of the lower leg. Soft tissue and bones were covered with dirt and pieces of clothing. The wounds were thoroughly rinsed and dirt was removed followed by detailed debridement. After primary surgical treatment of the wound, open proximal lower leg fracture was stabilized with external skeletal fixation using two nails in the proximal and two nails in the distal fragment. Soft tissue defect was treated by plastic surgeon. The patient was administered anti-tetanus protection, antibiotic treatment and anticoagulant prophylaxis of deep vein thrombosis and pulmonary thromboembolism. Physical therapy was initiated subsequent to successful healing of the soft tissue wounds. External skeletal fixation was removed after three months for infection around the proximal nails and the treatment was contuinued using functional Sarmiento’s plaster imobilization leading to full recovery of open lower leg fracture.

  4. Restless Legs Syndrome and Leg Motor Restlessness in Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    Keisuke Suzuki

    2015-01-01

    Full Text Available Sleep disturbances are important nonmotor symptoms in Parkinson’s disease (PD that are associated with a negative impact on quality of life. Restless legs syndrome (RLS, which is characterized by an urge to move the legs accompanied by abnormal leg sensations, can coexist with PD, although the pathophysiology of these disorders appears to be different. RLS and PD both respond favorably to dopaminergic treatment, and several investigators have reported a significant relationship between RLS and PD. Sensory symptoms, pain, motor restlessness, akathisia, and the wearing-off phenomenon observed in PD should be differentiated from RLS. RLS in PD may be confounded by chronic dopaminergic treatment; thus, more studies are needed to investigate RLS in drug-naïve patients with PD. Recently, leg motor restlessness (LMR, which is characterized by an urge to move the legs that does not fulfill the diagnostic criteria for RLS, has been reported to be observed more frequently in de novo patients with PD than in age-matched healthy controls, suggesting that LMR may be a part of sensorimotor symptoms intrinsic to PD. In this paper, we provide an overview of RLS, LMR, and PD and of the relationships among these disorders.

  5. A Review of the Investigation of the Thermoelectric Inhomogeneity of Thermocouple Wires%热电偶不均匀性研究现状与进展

    Institute of Scientific and Technical Information of China (English)

    杨斌; 王惠龄

    2015-01-01

    热电偶不均匀性是影响热电偶测温精度的主要因素之一。本文总结了热电偶不均匀性的研究现状,和目前高温、中温及低温范围内不均匀性测量设备的工作原理、结构及其优缺点。对热电偶不均匀性还应进行更加深入系统地研究,以如实反映热电偶制造、使用全过程中对测温准确性产生影响的因素,以建立热电偶的质量控制系统。%Thermocouple inhomogeneity is one of the major factors that influence the accuracy of temperature measurement. This paper made a brief summary of the research status on thermocouple inhomogeneity and the working principle, structure and the merits and demerits of the different kinds of test equippments used in different temperature range.A set of test trig used in the cryogenic conditions was also designed and manufactured. There should have more detailed and thorough research on the thermocouple inhomogeneity,to enlight all the factors that influence the improvement of the thermometry accurarcy through the whole life cycle of thermocouples,and to establish the quality control system for the thermocouples.

  6. Development of a Novel Split Type Energy Saving Thermocouple%一种分体式节能热电偶的研制

    Institute of Scientific and Technical Information of China (English)

    丁锡端; 丁刚; 袁振东

    2012-01-01

    Based on the problem of abrasion, corrosion and brittleness rupture of flange at the wield bottom part occurred for thermocouple protection jacket in petrochemical field at home and abroad, a fissional thermocouple is developed. The developed disassembly thermocouple, which adopts the novel alloy material, the integration forging modeling and deep blind drill technology, can replace the traditional wielding technique. It solves the protection jacket and flange material problem rationally. It not only sharply increases the thermocouple jacket abrasion and corrosion resistance performance, but also save the flange material efficiently, and is a novel energy saving thermocouple.%针对国内外石油化工领域存在的热电偶保护套管的磨损、腐蚀和法兰根部焊接区域脆性断裂等问题,采用自主研发的新型合金材料、整体锻压成型及深盲钻孔技术研制了一种分体式可拆卸热电偶,替代了传统的焊接工艺,合理解决了保护套管与法兰材质的问题。不仅提高了热电偶保护套管的耐磨损和耐腐蚀性能,而且有效节省了法兰材料,是一种新型的节能热电偶。

  7. Analysis on the thermocouple calibration should pay attention question%浅析热电偶在检定时应注意的问题

    Institute of Scientific and Technical Information of China (English)

    罗海军; 何志斌

    2014-01-01

    Thermocouple temperature sensor is commonly used in a variety of temperature measure-ment sites, for the thermocouple temperature measurement process can accurately measure the tempera-ture of the thermocouple to test. There are many factors that affect the accuracy of test results in the certi-fication process, such as the length of the thermocouple itself, appearance, bending, insulation resist-ance and insertion depth test operation on the heating rate, citing compensation wire, etc. Of the above factors were collation and analysis of the test results of the thermocouple to avoid inaccuracies in the test.%热电偶是目前各种测温场所普遍使用的温度传感器,为使热电偶在测温过程中能够准确测量温度,要对热电偶进行检定。在检定过程中有很多因素影响检定结果的准确性,如热电偶本身的长度、外观、弯曲度、绝缘电阻以及检定操作上的插入深度、升温速率、补偿导线的引用等,对以上因素进行了整理和分析,使热电偶在检定中避免了检定结果的不准确性。

  8. Leg movements during wakefulness in restless legs syndrome: time structure and relationships with periodic leg movements during sleep.

    Science.gov (United States)

    Ferri, Raffaele; Manconi, Mauro; Plazzi, Giuseppe; Bruni, Oliviero; Cosentino, Filomena I I; Ferini-Strambi, Luigi; Zucconi, Marco

    2012-05-01

    Approximately one third of patients with restless legs syndrome (RLS) also show periodic leg movements (PLM) during relaxed wake fulness (PLMW). In contrast with the large amount of data published on periodic leg movements during sleep (PLMS), PLMW have received less attention from the scientific community. The objective of this study was to evaluate the correlations/differences of time-structure and response to a dopamine-agonist between PLMW and PLMS in patients with RLS. Ninety idiopathic RLS patients and 28 controls were recruited. Subjects underwent clinical and neurophysiological evaluation, hematological screening, and one or two consecutive full-night polysomnographic studies. A subset of patients received 0.25mg of pramipexole or placebo before the second recording. Polysomnographic recordings were scored and LM activity was analyzed during sleep and during the epochs of wakefulness occurring during the first recording hour. RLS patients had higher LM activity during wakefulness than controls, but with a similar periodicity. Even if correlated, the ability of the PLMW index to predict the PLMS index decreased with increasing LM activity. Intermovement intervals during wakefulness showed one peak only at approximately 4s, gradually decreasing with increasing interval in both patients and controls. The effect of pramipexole was very limited and involved the small periodic portion of LM activity during wakefulness. PLMW index and PLMS index were correlated; however, the magnitude of this correlation was not sufficient to suggest that PLMW can be good predictors of PLMS. Short-interval LM activity during wakefulness and sleep might be linked to the severity of sleep disruption in RLS patients and the differences between their features obtained during wakefulness or sleep might be relevant for the diagnosis of sleep disturbances in RLS. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Profile of altered brain iron acquisition in restless legs syndrome

    Science.gov (United States)

    Ponnuru, Padmavathi; Wang, Xin-Sheng; Patton, Stephanie M.; Allen, Richard P.; Earley, Christopher J.

    2011-01-01

    Restless legs syndrome is a neurological disorder characterized by an urgency to move the legs during periods of rest. Data from a variety of sources provide a compelling argument that the amount of iron in the brain is lower in individuals with restless legs syndrome compared with neurologically normal individuals. Moreover, a significant percentage of patients with restless legs syndrome are responsive to intravenous iron therapy. The mechanism underlying the decreased iron concentrations in restless legs syndrome brains is unknown. We hypothesize that the source of the brain iron deficit is at the blood–brain interface. Thus we analysed the expression of iron management proteins in the epithelial cells of the choroid plexus and the brain microvasculature in post-mortem tissues. The choroid plexus, obtained at autopsy, from 18 neurologically normal controls and 14 individuals who had primary restless legs syndrome was subjected to histochemical staining for iron and immunostaining for iron management proteins. Iron and heavy chain ferritin staining was reduced in the epithelial cells of choroid plexus in restless legs syndrome. Divalent metal transporter, ferroportin, transferrin and its receptor were upregulated in the choroid plexus in restless legs syndrome. Microvessels were isolated from the motor cortex of 11 restless legs syndrome and 14 control brains obtained at autopsy and quantitative immunoblot analyses was performed. Expression of heavy chain ferritin, transferrin and its receptor in the microvessels from restless legs syndrome was significantly decreased compared with the controls but divalent metal protein 1, ferroportin, prohepcidin, mitochondrial ferritin and light-chain ferritin remained unchanged. The presence of an iron regulatory protein was demonstrated in the brain microvasculature and the activity of this protein is decreased in restless legs syndrome; a finding similar to our earlier report in neuromelanin cells from the substantia

  10. Profile of altered brain iron acquisition in restless legs syndrome.

    Science.gov (United States)

    Connor, James R; Ponnuru, Padmavathi; Wang, Xin-Sheng; Patton, Stephanie M; Allen, Richard P; Earley, Christopher J

    2011-04-01

    Restless legs syndrome is a neurological disorder characterized by an urgency to move the legs during periods of rest. Data from a variety of sources provide a compelling argument that the amount of iron in the brain is lower in individuals with restless legs syndrome compared with neurologically normal individuals. Moreover, a significant percentage of patients with restless legs syndrome are responsive to intravenous iron therapy. The mechanism underlying the decreased iron concentrations in restless legs syndrome brains is unknown. We hypothesize that the source of the brain iron deficit is at the blood-brain interface. Thus we analysed the expression of iron management proteins in the epithelial cells of the choroid plexus and the brain microvasculature in post-mortem tissues. The choroid plexus, obtained at autopsy, from 18 neurologically normal controls and 14 individuals who had primary restless legs syndrome was subjected to histochemical staining for iron and immunostaining for iron management proteins. Iron and heavy chain ferritin staining was reduced in the epithelial cells of choroid plexus in restless legs syndrome. Divalent metal transporter, ferroportin, transferrin and its receptor were upregulated in the choroid plexus in restless legs syndrome. Microvessels were isolated from the motor cortex of 11 restless legs syndrome and 14 control brains obtained at autopsy and quantitative immunoblot analyses was performed. Expression of heavy chain ferritin, transferrin and its receptor in the microvessels from restless legs syndrome was significantly decreased compared with the controls but divalent metal protein 1, ferroportin, prohepcidin, mitochondrial ferritin and light-chain ferritin remained unchanged. The presence of an iron regulatory protein was demonstrated in the brain microvasculature and the activity of this protein is decreased in restless legs syndrome; a finding similar to our earlier report in neuromelanin cells from the substantia nigra

  11. Actigraphic assessment of periodic leg movements in patients with restless legs syndrome.

    Science.gov (United States)

    Cippà, Maria A T; Baumann, Christian R; Siccoli, Massimiliano M; Bassetti, Claudio L; Poryazova, Rositsa; Werth, Esther

    2013-10-01

    The diagnosis of restless legs syndrome (RLS) relies upon diagnostic criteria which are based on history only, and dopaminergic treatment is not normally the first choice of treatment for all patients. It would be worthwhile to identify patients non-responsive to dopaminergic treatment beforehand, because they may suffer from a restless legs-like syndrome and may require alternative treatment. We included retrospectively 24 adult patients fulfilling the four essential criteria for restless legs and 12 age-matched healthy controls. They were investigated by ambulatory actigraphy from both legs over three nights, and patients started treatment with dopamine agonists after this diagnostic work-up. We examined 12 responders to dopaminergic treatment and 12 non-responders and studied the association between response to dopaminergic treatment and the periodic limb movement index (PLMI) as assessed with actigraphy. Demographic characteristics, excessive daytime sleepiness and fatigue at baseline were similar in all three groups. Baseline RLS severity was similar between responders and non-responders [International Restless Legs Severity Scale (IRLS): 25 ± 9 and 24 ± 8]. Group comparisons of PLMI before treatment initiation showed significant differences between the three groups. Post-hoc pairwise comparisons revealed that healthy controls had significantly lower PLMI (4.9 ± 4.5) than responders (29.3 ± 22.7) and non-responders (13.3 ± 11.2). Similarly, the PLMI in responders was lower than in non-responders. PLMI day-to-day variability did not differ between responders and non-responders and there was no correlation between treatment effect, as assessed by the decrease of the IRLS and baseline PLMI. Our retrospective study indicates that actigraphy to assess periodic limb movements may contribute to a better diagnosis of dopamine-responsive restless legs syndrome.

  12. The natural shock absorption of the leg spring.

    Science.gov (United States)

    Kim, Wangdo; João, Filipa; Tan, John; Mota, Patricia; Vleck, Veronica; Aguiar, Liliana; Veloso, Antonio

    2013-01-04

    When a human being runs, muscles, tendons, and ligaments together behave like a single linear spring. This "leg spring" can be described remarkably well by spring/mass models. Although leg-stiffness during running (and logically, therefore, in hopping) has been shown to be adjusted in line with the individual characteristics of the external contact surface, the relative contribution of each of the sub-components of the leg spring to the mechanics of running is unclear. We proposed the three-degree-of-freedom leg spring chain in a position of stable equilibrium under the action of the leg stiffness. If the leg spring receives a displacement in hopping, the forces will no longer equilibrate, but the system will be exposed to the action of a force on a leg spring chain. We thus have two corresponding sets of modes, one set being the mode about which the chain is displaced, the other set for the forces which are evoked in consequence of the displacement. We found that if the leg has been displaced from a position of equilibrium about one of harmonic modes, then a vibration about this harmonic mode evokes a system of forces in the leg spring which in its turn tends to produce a motion on the original harmonic mode, and thus produce oscillation about the same harmonic mode. Our results suggest that the desired harmonic mode can be explained in terms of the natural shock absorption ability of the leg.

  13. Leg stiffness of sprinters using running-specific prostheses

    Science.gov (United States)

    McGowan, Craig P.; Grabowski, Alena M.; McDermott, William J.; Herr, Hugh M.; Kram, Rodger

    2012-01-01

    Running-specific prostheses (RSF) are designed to replicate the spring-like nature of biological legs (bioL) during running. However, it is not clear how these devices affect whole leg stiffness characteristics or running dynamics over a range of speeds. We used a simple spring–mass model to examine running mechanics across a range of speeds, in unilateral and bilateral transtibial amputees and performance-matched controls. We found significant differences between the affected leg (AL) of unilateral amputees and both ALs of bilateral amputees compared with the bioL of non-amputees for nearly every variable measured. Leg stiffness remained constant or increased with speed in bioL, but decreased with speed in legs with RSPs. The decrease in leg stiffness in legs with RSPs was mainly owing to a combination of lower peak ground reaction forces and increased leg compression with increasing speeds. Leg stiffness is an important parameter affecting contact time and the force exerted on the ground. It is likely that the fixed stiffness of the prosthesis coupled with differences in the limb posture required to run with the prosthesis limits the ability to modulate whole leg stiffness and the ability to apply high vertical ground reaction forces during sprinting. PMID:22337629

  14. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football

    Science.gov (United States)

    Hart, Nicolas H.; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L.; Newton, Robert U.

    2016-01-01

    Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2) each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15) and inaccurate (n = 16) kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701). Relative lean mass was positively correlated with kicking accuracy (r = 0.631), while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083). Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy. Key points Accurate kickers expressed a very strong inverse relationship between leg mass and foot velocity. Inaccurate kickers were unable to replicate this, with greater volatility in their performance, indicating an ability of accurate kickers to mediate foot velocity to compensate for leg mass in order to deliver the ball over the required distance. Accurate kickers exhibited larger quantities of relative lean mass and lower

  15. Cold fiber solid-phase microextraction device based on thermoelectric cooling of metal fiber.

    Science.gov (United States)

    Haddadi, Shokouh Hosseinzadeh; Pawliszyn, Janusz

    2009-04-03

    A new cold fiber solid-phase microextraction device was designed and constructed based on thermoelectric cooling. A three-stage thermoelectric cooler (TEC) was used for cooling a copper rod coated with a poly(dimethylsiloxane) (PDMS) hollow fiber, which served as the solid-phase microextraction (SPME) fiber. The copper rod was mounted on a commercial SPME plunger and exposed to the cold surface of the TEC, which was enclosed in a small aluminum box. A heat sink and a fan were used to dissipate the generated heat at the hot side of the TEC. By applying an appropriate dc voltage to the TEC, the upper part of the copper rod, which was in contact to the cold side of the TEC, was cooled and the hollow fiber reached a lower temperature through heat transfer. A thermocouple was embedded in the cold side of the TEC for indirect measurement of the fiber temperature. The device was applied in quantitative analysis of off-flavors in a rice sample. Hexanal, nonanal, and undecanal were chosen as three off-flavors in rice. They were identified according to their retention times and analyzed by GC-flame ionization detection instrument. Headspace extraction conditions (i.e., temperature and time) were optimized. Standard addition calibration graphs were obtained at the optimized conditions and the concentrations of the three analytes were calculated. The concentration of hexanal was also measured using a conventional solvent extraction method (697+/-143ng/g) which was comparable to that obtained from the cold fiber SPME method (644+/-8). Moreover, the cold fiber SPME resulted in better reproducibility and shorter analysis time. Cold fiber SPME with TEC device can also be used as a portable device for field sampling.

  16. Cold asymmetrical fermion superfluids

    Energy Technology Data Exchange (ETDEWEB)

    Caldas, Heron

    2003-12-19

    The recent experimental advances in cold atomic traps have induced a great amount of interest in fields from condensed matter to particle physics, including approaches and prospects from the theoretical point of view. In this work we investigate the general properties and the ground state of an asymmetrical dilute gas of cold fermionic atoms, formed by two particle species having different densities. We have show in a recent paper, that a mixed phase composed of normal and superfluid components is the energetically favored ground state of such a cold fermionic system. Here we extend the analysis and verify that in fact, the mixed phase is the preferred ground state of an asymmetrical superfluid in various situations. We predict that the mixed phase can serve as a way of detecting superfluidity and estimating the magnitude of the gap parameter in asymmetrical fermionic systems.

  17. Cold nuclear fusion

    Directory of Open Access Journals (Sweden)

    Huang Zhenqiang Huang Yuxiang

    2013-10-01

    Full Text Available In normal temperature condition, the nuclear force constraint inertial guidance method, realize the combination of deuterium and tritium, helium and lithium... And with a magnetic moment of light nuclei controlled cold nuclear collide fusion, belongs to the nuclear energy research and development in the field of applied technology "cold nuclear collide fusion". According to the similarity of the nuclear force constraint inertial guidance system, the different velocity and energy of the ion beam mixing control, developed ion speed dc transformer, it is cold nuclear fusion collide, issue of motivation and the nuclear power plant start-up fusion and power transfer system of the important equipment, so the merger to apply for a patent

  18. High performance p-type segmented leg of misfit-layered cobaltite and half-Heusler alloy

    DEFF Research Database (Denmark)

    Le, Thanh Hung; Van Nong, Ngo; Snyder, Gerald Jeffrey;

    2015-01-01

    In this study, a segmented p-type leg of doped misfit-layered cobaltite Ca2.8Lu0.15Ag0.05Co4O9+δ and half-Heusler Ti0.3Zr0.35Hf0.35CoSb0.8Sn0.2 alloy was fabricated and characterized. The thermoelectric properties of single components, segmented leg, and the electrical contact resistance...... of the joint part were measured as a function of temperature. The output power generation characteristics of segmented legs were characterized in air under various temperature gradients, DT, with the hot side temperature up to 1153 K. At ΔT ≈756 K, the maximum conversion efficiency reached a value of ∼5......%, which is about 65% of that expected from the materials without parasitic losses. The long-term stability investigation for two weeks at the hot and cold side temperatures of 1153/397 K shows that the segmented leg has good durability as a result of stable and low electrical resistance contacts. 2015...

  19. Sympathetic nervous system activation reduces contraction-induced rapid vasodilation in the leg of humans independent of age.

    Science.gov (United States)

    Hughes, William E; Kruse, Nicholas T; Casey, Darren P

    2017-07-01

    Contraction-induced rapid vasodilation is attenuated similarly in the upper and lower limbs of older adults. In the forearm, this attenuation is in part due to a greater sympathetic vasoconstriction. We examined whether the age-related reduction in contraction-induced vasodilation in the leg is also due to a sympathetic vasoconstrictive mechanism. Thirteen young (24 ± 1 yr) and twelve older adults (67 ± 1 yr) performed single-leg knee extension at 20 and 40% of work-rate maximum (WRmax) during control and cold-pressor test (CPT) conditions. Femoral artery diameter and blood velocity were measured using Doppler ultrasound. Vascular conductance (VC; ml·min(-1)·mmHg(-1)) was calculated using blood flow (ml/min) and mean arterial pressure (mmHg). Peak (ΔVC from baseline) and total VC were blunted in older adults during control conditions across exercise intensities (P ROV). Within the forearm, this attenuation is partially due to enhanced sympathetic vasoconstriction. In the current study, we found that sympathetic vasoconstriction reduces contraction-induced ROV within the leg of both young and older adults, with the magnitude of change being similar between age groups. Our current results suggest that age-related attenuations in contraction-induced ROV within the leg are not fully explained by a sympathetic vasoconstrictor mechanism. Copyright © 2017 the American Physiological Society.

  20. D-ribose benefits restless legs syndrome.

    Science.gov (United States)

    Shecterle, Linda; Kasubick, Robert; St Cyr, John

    2008-11-01

    Restless legs syndrome is a neurological disorder characterized by unpleasant sensations and pain, predominantly in the lower extremities while at rest, accompanied by an uncontrollable urge for movement for relief. We report on two affected male individuals, a father and son, ages 71 and 47, from a family in which three generations carry the diagnosis. To evaluate any potential benefit of D-ribose in this condition, each individual orally consumed 5-g doses of D-ribose daily at different trial stages. Each stage lasted 3 weeks with a 2-week washout period between stages. The initial stage involved a single 5 gm dose of D-ribose consumed at breakfast. Throughout the second stage, D-ribose was taken at breakfast and lunch. In the third stage, D-ribose was taken at all meals, breakfast, lunch, and dinner. Diaries by the subjects pertaining to their documentation and severity of restless legs syndrome symptoms was compiled. During the initial stage both men reported a general feeling of more energy and less fatigue, most notably after exercise, without any significant changes in their symptoms. With the increase in the daily dose of D-ribose, in the second stage, their leg twitching and the feeling to move during the day was reduced for 1 subject, and rarely present in the other. Both still experienced the unpleasant sensations during the night. However, during the final stage, a further increase in the daily dose of D-ribose eliminated their daily symptoms and the symptoms at night were of a lesser degree and had a later occurrence. Both men reported that D-ribose did not totally eliminate their discomfort, but the severity and onset of symptoms affecting their quality of life was substantially improved with D-ribose without any adverse reactions.

  1. [Bow legged adjectives in ancient literature].

    Science.gov (United States)

    Simon, Frantisek; Steger, Florian

    2011-01-01

    This article addresses the issue of capturing the medical entity called 'curved legs' in a terminologically exact way. In so doing, it refers to the long-lasting process of differentiation of exact nuances of meaning in Ancient Greek and Latin. In the chronological perusal of ancient Greek literature, it becomes evident that the various adjectives employed are often vague when looking at non-medical literature. By contrast, in the Hippocratic corpus these terms are for the first time annotated with explanations intended to lead to a more precise understanding of the described deformity. Further attempts of differentiation can be found in the writings of Galen, who not only distinguishes between outward and inward curvatures, but also between deformities of the thigh and lower leg as well as between pathological and natural curvatures. Latin literature also provides a series of adjectives that were initially often used in the meaning of 'curved' but it was not until Celsus that these were differentiated with respect to the type and direction of the curvature. When comparing Greek and Latin adjectives, it turns out that though the Latin term blaesus can be traced back etymologically to the Greek word beta lambda alpha iota sigma ó zeta, the meaning of beta lambda alpha iota sigma ó zeta does not fully correspond to that of the Latin word. It is not before the later common transliteration of Greek words that this adjective took on the meaning of beta lambda alpha iota sigma ó zeta; however, this was finally lost again. In summary, the article concludes that exact word meanings in ancient literature are often unclear and precise ascriptions of meanings are inconsistent. In the case of "curved legs," this has led to misunderstandings regarding the respective types and directions of the curvature.

  2. Refractory leg ulcers associated with Klinefelter syndrome.

    Science.gov (United States)

    Yabuno, Yuto; Tosa, Mamiko; Iwakiri, Itaru; Nomoto, Shunichi; Kaneko, Mayuko; Kuwahara, Kousuke; Hyakusoku, Hiko; Murakami, Masahiro

    2015-01-01

    We present a man with refractory leg ulcers, bilateral varicosis of the lower extremities, and Buerger disease. Autoimmune work-up was negative. However, chromosome analysis showed Klinefelter syndrome (48 XXY). Ulcerative lesions of the lower extremities are a complication of Klinefelter syndrome. To date, the pathogenesis of ulcers in Klinefelter syndrome has not been clarified, but several factors, such as abnormalities of fibrinolysis and prothrombotic states, might be involved. Our present case emphasizes the importance of considering Klinefelter syndrome in the differential diagnosis of a male patient with nonhealing ulcers of the lower extremities.

  3. Leg ulcer in lepromatous leprosy - Case report*

    Science.gov (United States)

    Fernandes, Tania Rita Moreno de Oliveira; dos Santos, Talita Suzany Siqueira; Lopes, Ramon Rodrigues de Macedo

    2016-01-01

    In Brazil, leprosy is a widespread infectious and contagious disease. Clinicians and specialists view leprosy broadly as a systemic infection, since, in its manifestations, it mimics many conditions, such as rheumatic, vascular, ENT, neurological and dermatological diseases. There are few studies that characterize the factors associated with ulcers in leprosy. These injuries should be prevented and treated promptly to avoid serious problems like secondary infections, sepsis, carcinomatous degeneration and amputations. We describe a patient with ulcers on his legs, involving late diagnosis of lepromatous leprosy. PMID:27828650

  4. Coordinated intelligent adaptive control of legged robots

    Science.gov (United States)

    McLauchlan, Lifford; Mehrübeoğlu, Mehrübe

    2006-05-01

    In planetary or hazardous environment exploration, there will be unforseen environmental circumstances which can not be planned. To overcome telerobotic control issues due to communication delays, autonomous robot control becomes necessary. Autonomously controlled landers and instrumentation can be used in exploration, such as lunar and martian missions. However, wheeled robots have difficulty in exploring uneven terrain; thus, legged robots can be used in such situations. This research develops intelligent and adaptive control of mobile robots to perform functions such as environmental exploration in coordination and obstacle avoidance. The coordinated control is demonstrated in simulations.

  5. Painful legs and moving toes syndrome

    Directory of Open Access Journals (Sweden)

    Qiu-ying Ma

    2015-10-01

    Full Text Available Painful legs and moving toes syndrome (PLMT is a rare movement disorder with low diagnostic rate, which is characterized by lower limb pain with involuntary movements of feet or toes. Etiology and pathogenesis of this disease is still unclear. Patients have different clinical manifestations, so the diagnosis is difficult. Treatment methods for PLMT are numerous, but so far the treatment of this disease is still a major challenge for clinicians. Further research is still needed to guide clinical work. DOI: 10.3969/j.issn.1672-6731.2015.10.013

  6. Cold regions isotope applications

    Energy Technology Data Exchange (ETDEWEB)

    Perrigo, L.D.; Divine, T.E.

    1976-04-01

    Pacific Northwest Laboratories (PNL) started the Cold Regions Isotope Applications Program in FY-1975 to identify special conditions in the Arctic and similar geographic areas (Cold Regions) where radioisotope power, heater, or sterilization systems would be desirable and economically viable. Significant progress was made in the first year of this program and all objectives for this initial 12-month period were achieved. The major conclusions and recommendations resulting for this effort are described below. The areas of interest covered include: radiosterilization of sewage; heating of septic tanks; and radioisotope thermoelectric generators as power sources for meteorological instruments and navigational aids. (TFD)

  7. 基于 NANM AC 热电偶的时间常数测试技术研究%Research on measuring time constant of NANMAC thermocouple

    Institute of Scientific and Technical Information of China (English)

    冯浩; 张志杰; 黄晓敏; 张晋文

    2014-01-01

    The theory for measuring the time constant of thermocouple was introduced ,and the method for measuring the time constant of NANMAC thermocouple by using dynamic calibration system of transient surface temperature sensor was proposed .In this system ,static and dynamic calibrations were conducted for infrared detectors and thermocouples ,and then both temperature-time curves were obtained .Since the frequency response of infrared detector is superior to that of calibrat -ed thermocouple ,the values measured by infrared detectors are taken as true values .Through dividing the values measured with thermocouples by those with infrared detectors ,a normalized curve was obtained ,based on which the time constant of thermocouple was measured .With this method ,the experiments were carried out with NANMAC thermocouple to obtain its time constant .The results show that the method for measuring the time constant is feasible and the dynamic calibration of thermocouples can be achieved at microsecond and millisecond level .This research has a certain reference value for research and application of NANMAC thermocouple temperature sensor .%本文介绍了热电偶时间常数的测试理论,提出了运用瞬态表面温度传感器动态校准系统实现对NANMAC 热电偶时间常数的测试方法。该系统对红外探测器和热电偶进行了静态校准和动态校准,得到两者的温度-时间曲线。由于红外探测器的频率响应优于被校准热电偶的频率响应,因此,以红外探测器测得的值作为真值,用热电偶测得的值与红外探测器测得的值相比得到一条归一化的曲线,并由归一化曲线求得热电偶的时间常数。利用该方法对 NANMAC 热电偶进行时间常数的测试实验,得到了该热电偶的时间常数。实验结果表明:该时间常数测试方法是可行的,可以实现对微秒、毫秒量级热电偶的动态校准,这对于 NANMAC 热电偶温度传感器的研究

  8. Restless Legs Syndrome After Single Low Dose Quetiapine Administration.

    Science.gov (United States)

    Soyata, Ahmet Z; Celebi, Fahri; Yargc, Lutfi I

    2016-01-01

    Restless legs syndrome is an underdiagnosed sensori-motor disorder and psychotropic drugs are one of the main secondary causes of the illness. The most common psychotropic agents that cause restless legs syndrome are antidepressants; however, antipsychotics have also been reported to induce restless legs syndrome. The prevalence, vulnerability factors and the underlying mechanism of antipsychotic-induced restless legs syndrome are unclear. A possible explanation is that dopaminergic blockade is the main precipitator of the syndrome. Quetiapine-induced restless legs syndrome is another point of interest because of its low binding to D2 receptors. We herein report the case of a restless legs syndrome that emerged after a single low dose quetiapine administration.

  9. Mechanical Engineering of Leg Joints of Anthropomorphic Robot

    Directory of Open Access Journals (Sweden)

    Pavluk Nikita

    2016-01-01

    Full Text Available The problem of design engineering of anthropomorphic robot legs is considered. An overview of the existing anthropomorphic robots and an analysis of servomechanisms and bearing parts involved in the assembly of robot legs are presented. We propose an option for constructing the legs of the robot Antares under development. A two-motor layout, used in the knee, ensures higher joint power along with independent interaction with the neighboring upper and lower leg joints when bending. To reduce the electrical load on the main battery of the robot, the upper legs are provided with a mounting pad for additional batteries powering servos. Direct control of the servos is also carried out through the sub-controllers, responsible for all 6 engines installed in the articular joints of the robot legs.

  10. Commemoration of a cold war

    DEFF Research Database (Denmark)

    Farbøl, Rosanna

    2015-01-01

    This article brings together the fields of Cold War studies and memory studies. In Denmark, a remarkable institutionalisation of Cold War memory has taken place in the midst of a heated ideological battle over the past and whether to remember the Cold War as a ‘war’. Using Danish Cold War museums...... and heritage sites as case studies, this article sheds new light on the politics of history involved in Cold War commemoration. It suggests that the Cold War is commemorated as a war, yet this war memory is of a particular kind: it is a war memory without victims....

  11. Stable bipedal walking with a swing-leg protraction strategy.

    Science.gov (United States)

    Bhounsule, Pranav A; Zamani, Ali

    2017-01-25

    In bipedal locomotion, swing-leg protraction and retraction refer to the forward and backward motion, respectively, of the swing-leg before touchdown. Past studies have shown that swing-leg retraction strategy can lead to stable walking. We show that swing-leg protraction can also lead to stable walking. We use a simple 2D model of passive dynamic walking but with the addition of an actuator between the legs. We use the actuator to do full correction of the disturbance in a single step (a one-step dead-beat control). Specifically, for a given limit cycle we perturb the velocity at mid-stance. Then, we determine the foot placement strategy that allows the walker to return to the limit cycle in a single step. For a given limit cycle, we find that there is swing-leg protraction at shallow slopes and swing-leg retraction at steep slopes. As the limit cycle speed increases, the swing-leg protraction region increases. On close examination, we observe that the choice of swing-leg strategy is based on two opposing effects that determine the time from mid-stance to touchdown: the walker speed at mid-stance and the adjustment in the step length for one-step dead-beat control. When the walker speed dominates, the swing-leg retracts but when the step length dominates, the swing-leg protracts. This result suggests that swing-leg strategy for stable walking depends on the model parameters, the terrain, and the stability measure used for control. This novel finding has a clear implication in the development of controllers for robots, exoskeletons, and prosthetics and to understand stability in human gaits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Leg stiffness of sprinters using running-specific prostheses

    OpenAIRE

    McGowan, Craig P.; Grabowski, Alena M.; McDermott, William J.; Herr, Hugh M.; Kram, Rodger

    2012-01-01

    Running-specific prostheses (RSF) are designed to replicate the spring-like nature of biological legs (bioL) during running. However, it is not clear how these devices affect whole leg stiffness characteristics or running dynamics over a range of speeds. We used a simple spring–mass model to examine running mechanics across a range of speeds, in unilateral and bilateral transtibial amputees and performance-matched controls. We found significant differences between the affected leg (AL) of uni...

  13. COLD VRS HEAT AFTER EXERCISE- IS THERE A CLEAR WINNER FOR MUSCLE SORENESS.

    Science.gov (United States)

    Petrofsky, Jerrold; Khowailed, Iman Akef; Lee, Haneul; Berk, Lee; Bains, Gurinder; Akerkar, Siddhesh; Shah, Jinal; Al-Dabbak, Fuad; Laymon, Mike

    2015-08-14

    Due to the differences in the exercise type, temperature and timing of the use of cold and heat after exercise in different studies, there is no clear conclusion as to the efficacy of either modality on reducing delayed onset muscle soreness. One hundred subjects at similar fitness levels were examined. They accomplished leg squats for 15 minutes and heat and cold were applied after or 24 hours after exercise using ThermaCare heat or cold wraps. Measurements obtained were strength, the force to passively move the knee, analog visual pain scales, and blood myoglobin. Control subjects lost 24% strength after exercise. Subjects with heat or cold just after exercise only lost 4% strength (p<0.01). Cold applied after 24 hours was better than heat at 24 for strength recovery. Heat or cold applied after exercise was significantly better to prevent elastic tissue damage (p<0.01) while heat and cold immediate after exercise caused no loss in muscle myoglobin whereas heat or cold after 24 hours showed no less muscle damage from myoglobin than control subjects. Myoglobin in the control and heat and cold 24 groups averaged 135.1% of the baseline data but averaged 106.1% of baseline in the heat and cold immediate groups. For reducing pain, control subjects showed a significant amount of pain the days after exercise. But cold immediately after exercise or 24 hours later was superior to heat in reducing pain. In conclusion, both cold and heat appear to be efficacious in reducing muscle damage after exercise.

  14. Cold Vs. Heat After Exercise-Is There a Clear Winner for Muscle Soreness.

    Science.gov (United States)

    Petrofsky, Jerrold S; Khowailed, Iman Akef; Lee, Haneul; Berk, Lee; Bains, Gurinder S; Akerkar, Siddhesh; Shah, Jinal; Al-Dabbak, Fuad; Laymon, Mike S

    2015-11-01

    Because of the differences in the exercise type, temperature, and timing of the use of cold and heat after exercise in different studies, there is no clear conclusion as to the efficacy of either modality on reducing delayed onset muscle soreness. One hundred subjects at similar fitness levels were examined. They accomplished leg squats for 15 minutes and heat and cold were applied after or 24 hours after exercise using ThermaCare heat or cold wraps. Measurements obtained were strength, the force to passively move the knee, analog visual pain scales, and blood myoglobin. Control subjects lost 24% strength after exercise. Subjects with heat or cold just after exercise only lost 4% strength (p < 0.01). For strength recovery, cold applied after 24 hours was better than heat at 24 hours. Heat or cold applied after exercise was significantly better to prevent elastic tissue damage (p < 0.01), whereas heat and cold immediately after exercise caused no loss in muscle myoglobin and heat or cold after 24 hours showed no less muscle damage from myoglobin than in control subjects. Myoglobin in the control and heat and cold 24-hour groups averaged 135.1% of the baseline data but averaged 106.1% of baseline in the immediate heat and cold groups. For reducing pain, control subjects showed a significant amount of pain the days after exercise. But cold immediately after exercise or 24 hours later was superior to heat in reducing pain. In conclusion, both cold and heat appear to be efficacious in reducing muscle damage after exercise.

  15. 多通道热偶规真空计的设计%Design of multi-channel thermocouple vacuum gauge

    Institute of Scientific and Technical Information of China (English)

    董长盛; 周乔君; 陈泽熹; 戴华通

    2014-01-01

    真空计是测量真空度的仪器,目前市场上大多数热偶规真空计都是一个热偶规对应一个真空计,虽然有数值显示,但只有开关量的输出,没有实时数据的输出,不方便二次开发和利用。多通道热偶规真空计可以同时对8路热偶规的信号做出处理,并且通过 RS232将数据输出,可以更加直观的观察到真空度的变化。同时具有过载保护功能,当被测压力超出热偶规的量程时会自动切断恒流源对热偶规管进行保护。在使用的过程中不仅节省了空间,降低了测试成本,而且减少了复杂的布线。%Vacuum gauge is a measuring instrument for vacuum degree , on the market at present most of the thermocouple vacuum gauge is a thermocouple gauge corresponds to a vacuum gauge. Although there are numerical display, but only the switch quantity output, without output of real-time data, not making convenience for secondary development and utilization. Multi-chan-nel thermocouple vacuum gauge can simultaneously process 8-way thermocouple gauge signals , and output data through the RS232, which can more intuitively observe the change of vacuum degree. At the same time it have overload protection function, when the measured pressure beyond the range of thermocouple gauge , the constant current source is automatically cut off to pro-tect the thermocouple gauge. In the process of using it not only saves space, reduces the test cost, but also reduces the compli-cated wiring.

  16. Research on the thermocouple instrument calibration method%一种热电偶测量仪表的校准方法

    Institute of Scientific and Technical Information of China (English)

    孔繁军; 戴晶; 潘婧

    2012-01-01

    Introduced a method of the thermocouple instrument calibration. Using of Labview and high precision analog output card, the computer can translate the temperature difference into the 0 ~5V DC voltage output, and form the function relation from a variety of types of thermocouple degree, which is used to modify non-strict linear function of thermocouple EMF and temperature difference. Then the outside analog circuit translate the 0 ~ 5V voltage into the EMF. This method can achieve the thermocouple instrument calibration for a variety of types of thermocouple and range of temperature. According to data test and analysis, all errors of output EMF are acceptable, the method is easy operated and can be used for thermocouple instrument calibration.%提出了一种热电偶测量仪表的校准方法.采用Labview软件和高精度模拟输出板卡相结合的方法,将温差转化为0~5V的直流电压输出,将不同类型的热电偶分度表拟合出函数关系,用于纠正热电偶产生的热电动势和温差之间非严格线性关系,然后通过外部模拟运算电路将板卡输出电压转化为标准热电偶的温差电动势输出,可以实现多种类型热电偶测量仪表在不同使用温度范围的校准.经过数据测试及分析,输出的温差电动势均在允许的误差范围内,且操作简便,能很方便地用于热电偶测量仪表的校准.

  17. Determining Evapotranspiration with the Eddy Covariance Method: Fast-Response Dry- and Wet-Bulb Thermocouples for Humidity Measurements Can Provide a Cheap Alternative to Infrared Hygrometers.

    Science.gov (United States)

    Holwerda, F.; Alvarado-Barrientos, M. S.

    2014-12-01

    Field data on evapotranspiration are of crucial importance for ecohydrological and hydrometeorological studies in the tropics. Probably the most direct way to measure evapotranspiration is with the eddy covariance method, in which the latent heat flux (λE) is calculated from turbulent fluctuations of vertical wind velocity and humidity. The humidity fluctuations are typically measured with some type of fast-response infrared hygrometer. However, these sensors are expensive, which can be problematic if research budgets are limited. Turbulent fluctuations of humidity can also be measured with fast-response dry- and wet-bulb thermocouples, which can be constructed easily and at a fraction of the price of infrared sensors. The idea of using dry- and wet-bulb thermocouples for measuring λE with the eddy covariance method is not new, but hasn't been tested recently, possibly because experiments in the late seventies showed that this approach is not without problems due to the slow response of the wet-bulb thermocouple. In the present study, values of λE derived from dry- and wet-bulb thermocouple measurements were compared with those obtained using a fast-response KH20 hygrometer. Measurements were made above a shaded coffee plantation and a sugarcane crop in central Veracruz, Mexico. The agreement between λE obtained with the thermocouples (y) and the hygrometer (x) was very good for both vegetation covers: y = 0.98x + 5.0 (W m-2), r2 = 0.93 (coffee plantation); y = 0.99x - 13.3 (W m-2), r2 = 0.88 (sugarcane). However, the correction factor (CF) for high frequency loss in the wet-bulb temperature signal was considerably higher for the low-statured sugarcane crop (CF = 1.33) as compared to the taller shaded coffee plantation (CF = 1.09). Nevertheless, as long as care is taken in the derivation of this correction factor, reliable λE data can be obtained using the dry- and wet-bulb thermocouples, offering a cheap alternative to infrared hygrometers.

  18. Detection of cold pain, cold allodynia and cold hyperalgesia in freely behaving rats

    Directory of Open Access Journals (Sweden)

    Woolf Clifford J

    2005-12-01

    Full Text Available Abstract Background Pain is elicited by cold, and a major feature of many neuropathic pain states is that normally innocuous cool stimuli begin to produce pain (cold allodynia. To expand our understanding of cold induced pain states we have studied cold pain behaviors over a range of temperatures in several animal models of chronic pain. Results We demonstrate that a Peltier-cooled cold plate with ± 1°C sensitivity enables quantitative measurement of a detection withdrawal response to cold stimuli in unrestrained rats. In naïve rats the threshold for eliciting cold pain behavior is 5°C. The withdrawal threshold for cold allodynia is 15°C in both the spared nerve injury and spinal nerve ligation models of neuropathic pain. Cold hyperalgesia is present in the spared nerve injury model animals, manifesting as a reduced latency of withdrawal response threshold at temperatures that elicit cold pain in naïve rats. We also show that following the peripheral inflammation produced by intraplantar injection of complete Freund's adjuvant, a hypersensitivity to cold occurs. Conclusion The peltier-cooled provides an effective means of assaying cold sensitivity in unrestrained rats. Behavioral testing of cold allodynia, hyperalgesia and pain will greatly facilitate the study of the neurobiological mechanisms involved in cold/cool sensations and enable measurement of the efficacy of pharmacological treatments to reduce these symptoms.

  19. Lower leg electrical impedance after distal bypass surgery

    DEFF Research Database (Denmark)

    Belanger, G K; Bolbjerg, M L; Heegaard, N H

    1998-01-01

    Electrical impedance was determined in 13 patients following distal bypass surgery to evaluate lower leg oedema as reflected by its circumference. Tissue injury was assessed by the plasma concentration of muscle enzymes. After surgery, the volume of the control lower leg increased from 1250 (816...... of troponin I (n = 8). In conclusion, tissue injury was reflected by increases in muscle enzymes in plasma. We found an inverse correlation between lower leg electrical impedance and volume, but the deviation in electrical impedance was approximately twice that of the leg volume. Electrical impedance appears...

  20. Protection against high intravascular pressure in giraffe legs

    DEFF Research Database (Denmark)

    Petersen, Karin K; Hørlyck, Arne; Østergaard, Kristine Hovkjær

    2013-01-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination....... All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure....... revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along...

  1. Passive mechanical properties of legs from running insects.

    Science.gov (United States)

    Dudek, Daniel M; Full, Robert J

    2006-04-01

    While the dynamics of running arthropods have been modeled as a spring-mass system, no such structures have been discovered that store and return energy during bouncing. The hindleg of the cockroach Blaberus discoidalis is a good candidate for a passive, vertical leg spring because its vertically oriented joint axes of rotation limit the possibility of active movements and contributions of muscle properties. We oscillated passive legs while measuring force to determine the leg's dynamic, mechanical properties. The relative dimensionless stiffness of an individual cockroach leg was equal to that estimated for a single leg of a biped or quadruped. Leg resilience ranged from 60 to 75%, affording the possibility that the leg could function as a spring to store and return the mechanical energy required to lift and accelerate the center of mass. Because hysteresis was independent of oscillation frequency, we rejected the use of a Voigt model - a simple spring in parallel with a viscous damper. A hysteretic damping model fit the cockroach leg force-displacement data over a wide range of frequencies and displacement using just two parameters. Rather than simply acting as a spring to minimize energy, we hypothesize that legs must manage both energy storage and absorption for rapid running to be most effective.

  2. Tennis leg: mechanism of injury and radiographic presentation.

    Science.gov (United States)

    Pacheco, Rafael A; Stock, Harlan

    2013-08-01

    As summer is upon us, we thought a discussion of tennis leg would be beneficial to our fellow clinicians. Tennis leg is a relatively common clinical condition, classically manifesting as acute, sports-related pain in the mid-calf. First described in 1883, the pathogenesis has been debated--tennis leg was first attributed to rupture of the plantaris tendon, though more recent investigations have implicated rupture of the medial head of the gastrocnemius at its myotendinous junction. For simplicity, many authors use the term tennis leg to describe all such acute muscle injuries in the superficial calf.

  3. Compression Stockings for Treating Venous Leg Ulcers

    Directory of Open Access Journals (Sweden)

    J. P. Benigni

    2013-01-01

    Full Text Available Background. In order to treat venous leg ulcers, it is recommended to use high pressure compression (30–40 mmHg at the ankle. Compression stockings which are not operator dependant could be the best option because of their pressure control. However 30–40 mmHg compression stockings are often hard to put on. Putting two lower pressure compression stockings over each other could be a good therapeutic alternative. Objectives. To compare the in vitro pressures given by the manufacturers of 2 antiulcer kits with the in vivo interface pressures measured in healthy subjects and to evaluate the stiffness and friction indices from those kits based on the interface pressure in order to assess their clinical properties. Material and Methods. Using a Kikuhime pressure device, interface pressure was measured in 12 healthy subjects at the reference point B1. One stiffness index (Static Stiffness Index (SSI and a friction index have been calculated. Results. Mediven Ulcer kit gets the recommended pressures whereas Jobst’s Ulcer Care kit does not for treating a venous leg ulcer. Jobst’s Ulcer Care transmits entirely the pressure in relation to a friction index close to 1. Conclusion. This antiulcer kit study underlines that in vivo and in vitro pressures can be different (Jobst’s Ulcer Care kit and Mediven Ulcer kit. In order not to lose pressure, it is important to take into account the friction index when superimposing two stockings.

  4. Lower leg musculoskeletal geometry and sprint performance.

    Science.gov (United States)

    Karamanidis, Kiros; Albracht, Kirsten; Braunstein, Bjoern; Moreno Catala, Maria; Goldmann, Jan-Peter; Brüggemann, Gert-Peter

    2011-05-01

    The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N=11, 10.30±0.07s; slow: N=7, 10.70±0.08s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p>0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components.

  5. Restless legs syndrome in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Shahram Rafie

    2016-01-01

    Full Text Available Restless legs syndrome (RLS is a neurological disorder characterized by uncomfortable sensation of paresthesia in legs that subsequently causes involuntary and continuous movement of the lower limbs, especially at rest. Its prevalence in hemodialysis is more than that in the general population. Different risk factors have been suggested for RLS. We studied the prevalence and risk factors of RLS in 137 hemodialysis patients followed up at our center. The patients completed at least three months on dialysis and fulfilled four criteria for the diagnosis of RLS. We compared the patients with and without RLS, and the odds ratios (ORs were estimated by the logistic regression models. The prevalence of RLS was 36.5% in the study patients. Among the variables, diabetes was the only predicting factor for the development of RLS. The diabetic patients may be afflicted with RLS 2.25 times more than the non-diabetics. Women developed severe RLS 5.23 times more than men. Neurodegeneration, decrease in dopamine level, higher total oxidant status, and neuropathy in diabetic patients may explain the RLS symptoms.

  6. Migraine and restless legs syndrome: current perspectives

    Directory of Open Access Journals (Sweden)

    Ferreira KS

    2015-12-01

    Full Text Available Karen dos Santos Ferreira, Fabíola Dach, Alan L Eckeli, José Geraldo SpecialiDepartment of Neurosciences and Behavioral Sciences, Division of Neurology, University Hospital, Medical School of Ribeirao Preto, University of São Paulo, São Paulo, BrazilAbstract: The relationship between migraine and restless legs syndrome (RLS has been described in the literature for some years, based on clinical findings and pathophysiological considerations. There are some possible factors relating migraine and RLS. Both are diseases involving the central nervous system, the two diseases seem to share a dopaminergic mechanism, and it is also believed that they may share a genetic origin. At present, doctors who work with these two diseases should be encouraged not to simply investigate the simultaneous presence of both, but should also apply a treatment better adapted to this possibility. Research should be directed at some still unanswered questions for a better understanding of the association between migraine and RLS.Keywords: migraine, restless legs syndrome, physiopathology, comorbidities

  7. [RESTLESS LEGS SYNDROME--WILLIS-EKBOM DISEASE].

    Science.gov (United States)

    Ruppert, Élisabeth; Bataillard, Marc; Bourgin, Patrice

    2015-09-01

    Restless legs syndrome (RLS) is a sensorimotor disorder with a high prevalence (10% in Caucasian populations). It is a purely clinical diagnosis characterized by an urge to move the lower limbs usually accompanied or caused by unpleasant sensations in the legs with an improvement in symptoms with movement. These sensations occur during inactivity or at rest and worsen in the evening or at night. RLS may not only impact the quality of life for an individual, but may also increase mortality. Disease markers such as genetic predispositions have been identified, as well as reduced iron stores with altered intracerebral iron homeostasis and dopaminergic dysfunction. Medication is often necessary in severe forms, with low doses of dopaminergic agonists being the first-line of treatment. The use of α2δ ligands is an alternative. Finally benzodiazepines and opioid medications can be effective in refractory cases. In less severe forms of RLS, a non-pharmacological approach is usually sufficient with avoidance of stimulants and correction of contributing factors.

  8. Restless Legs Syndrome with Current Diagnostic Criteria

    Directory of Open Access Journals (Sweden)

    Meral Bilgilisoy Filiz

    2015-08-01

    Full Text Available Restless legs syndrome (RLS, also known as Willis-Ekbom disease, is a chronic movement disorder, characterized by an urge to move legs usually accompanied by uncomfortable sensations and sleep disorders. The prevalence of the syndrome ranges from 1% to 15% in the general population, and about 2% during childhood. RLS is the most common movement disorder in pregnancy. However RLS still remains underdiagnosed probably due to lack of accurate information about the disease. Family history is positive in 50-70% of the primary RLS patients. The secondary form of the syndrome is associated with iron deficiency, renal failure, pregnancy, diabetes mellitus and many rheumatologic disorders. Secondary forms generally manifest at older ages and have a rapid progression with a poorer prognosis. The pathophysiology of RLS is focused on the dopaminergic system, reduced central nervous system iron levels and genetic linkages. Diagnosis is based on clinical features and the diagnostic criteria suggested by International RLS Study Group. Secondary causes must be carefully investigated before the treatment. In mild forms of the disease non-pharmacologic therapies might be useful, while in moderate or severe forms of the disease generally pharmacologic therapies such as dopamine agonists, anticonvulsants, opioids and benzodiazepines are required. (Turkish Journal of Osteoporosis 2015;21: 87-95

  9. Restless legs syndrome in hemodialysis patients.

    Science.gov (United States)

    Rafie, Shahram; Jafari, Majid; Azizi, Mostafa; Bahadoram, Mohammad; Jafari, Shima

    2016-03-01

    Restless legs syndrome (RLS) is a neurological disorder characterized by uncomfortable sensation of paresthesia in legs that subsequently causes involuntary and continuous movement of the lower limbs, especially at rest. Its prevalence in hemodialysis is more than that in the general population. Different risk factors have been suggested for RLS. We studied the prevalence and risk factors of RLS in 137 hemodialysis patients followed up at our center. The patients completed at least three months on dialysis and fulfilled four criteria for the diagnosis of RLS. We compared the patients with and without RLS, and the odds ratios (ORs) were estimated by the logistic regression models. The prevalence of RLS was 36.5% in the study patients. Among the variables, diabetes was the only predicting factor for the development of RLS. The diabetic patients may be afflicted with RLS 2.25 times more than the non-diabetics. Women developed severe RLS 5.23 times more than men. Neurodegeneration, decrease in dopamine level, higher total oxidant status, and neuropathy in diabetic patients may explain the RLS symptoms.

  10. Cold spray nozzle design

    Science.gov (United States)

    Haynes, Jeffrey D.; Sanders, Stuart A.

    2009-06-09

    A nozzle for use in a cold spray technique is described. The nozzle has a passageway for spraying a powder material, the passageway having a converging section and a diverging section, and at least the diverging section being formed from polybenzimidazole. In one embodiment of the nozzle, the converging section is also formed from polybenzimidazole.

  11. Finger cold induced vasodilation

    NARCIS (Netherlands)

    Daanen, H.A.M.

    2007-01-01

    There are indications that subjects with a reduced finger CIVD response are more prone to get local cold injuries, but more epidemiological research is needed to establish a firm relationship. Although it was observed that an early CIVD onset was associated with initially superior manual performance

  12. Teaching "In Cold Blood."

    Science.gov (United States)

    Berbrich, Joan D.

    1967-01-01

    The Truman Capote nonfiction novel, "In Cold Blood," which reflects for adolescents the immediacy of the real world, illuminates (1) social issues--capital punishment, environmental influence, and the gap between the "haves" and "have-nots," (2) moral issues--the complexity of man's nature, the responsibility of one…

  13. Cold Weather Pet Safety

    Science.gov (United States)

    ... they can be knocked over, potentially starting a fire. Check your furnace before the cold weather sets in to make ... avoided because of the risk of burns or fire. Heated pet mats should also be used ... to burrow, get them back inside quickly because they are showing signs of ...

  14. Cold-induced metabolism

    NARCIS (Netherlands)

    Lichtenbelt, W. van Marken; Daanen, H.A.M.

    2003-01-01

    Purpose of review Cold response can be insulative (drop in peripheral temperature) or metabolic (increase in energy expenditure). Nonshivering thermogenesis by sympathetic, norepinephrine-induced mitochondrial heat production in brown adipose tissue is a well known component of this metabolic respon

  15. Chilling Out With Colds

    Science.gov (United States)

    ... some feel-better tips if you get a cold: Bring on the heat. Hot drinks soothe coughs and sore throats while also clearing mucus. So eat (or drink) your chicken soup! Get steamed up. A steamy shower helps stuffy or irritated noses. Or run a ...

  16. Out in the cold.

    Science.gov (United States)

    Bates, Jane

    2016-05-04

    Every now and then, you say something to a patient and wonder whether you should have kept quiet. On this occasion, a female patient and I were indulging in a moment of shared empathy over an annoying symptom we both experience - permanently cold feet.

  17. Cold War Propaganda.

    Science.gov (United States)

    Bennett, Paul W.

    1988-01-01

    Briefly discusses the development of Cold War propaganda in the United States, Canada, and the USSR after 1947. Presents two movie reviews and a Canadian magazine advertisement of the period which illustrate the harshness of propaganda used by both sides in the immediate postwar years. (GEA)

  18. Recent Cold War Studies

    Science.gov (United States)

    Pineo, Ronn

    2003-01-01

    Cold War historiography has undergone major changes since the 1991 collapse of the Soviet Union. For two years (1992-1993) the principal Soviet archives fell open to scholars, and although some of the richest holdings are now once again closed, new information continues to find its way out. Moreover, critical documentary information has become…

  19. Herpes Simplex Virus (Cold Sores)

    Science.gov (United States)

    ... Print Share Cold Sores in Children: About the Herpes Simplex Virus Page Content ​A child's toddler and ... Cold sores (also called fever blisters or oral herpes) start as small blisters that form around the ...

  20. An experimental investigation into the use of implanted thermocouples and differential thermometry as monitors for microvascular anastomoses.

    Science.gov (United States)

    Roberts, J O; Jones, B M; Greenhalgh, R M

    1985-10-01

    It has been suggested that direct monitoring of arterial temperature using implanted thermocouples, may have value as a clinical postoperative monitor for vascularized free tissue transfers, including those with no visible surfaces. This study evaluated the technique in experimental animals, using simple, inexpensive equipment. Mean arterial differential temperature changes, with ipsilateral (n = 20) and contralateral (n = 21) references, of 0.6 degrees C and 0.5 degrees C respectively, reliably indicated occlusion of the superficial femoral artery in situ. In epigastric island flaps, arterial occlusion (n = 24) produced mean arterial temperature changes of 0.5 degrees C, but changes after venous occlusion were not significantly greater than unoccluded base line fluctuation. Venous differential temperature did not change significantly after either arterial or venous occlusion. In six epigastric free flaps, success or failure could not be distinguished, as the wide variation in measurements in the four successful flaps overlapped the recordings in the two which failed. It was shown that the nearer to the body core, the less the temperature difference between arterial wall and periarterial tissue. Occlusion of deeply sited arteries produced little or no change in arterial temperature. In view of these findings and because of the invasive nature of the technique, the authors did not pursue it clinically.

  1. Analysis of Crystallization Behavior of Mold Fluxes Containing TiO2 Using Single Hot Thermocouple Technique

    Institute of Scientific and Technical Information of China (English)

    Yun LEI; Bing XIE; Wen-hui MA

    2016-01-01

    The crystallization behavior of mold fluxes containing 0-8 mass% TiO 2 was investigated using the single hot thermocouple technique (SHTT)and X-ray diffraction (XRD)to study the possible effects on the coordination of heat transfer control and strand lubrication for casting crack-sensitive peritectic steels.Time-temperature-transforma-tion (TTT)and continuous-cooling-transformation (CCT)curves were plotted using the data obtained from SHTT to characterize the crystallization of the mold fluxes.The results showed that crystallization of the mold fluxes during isothermal and non-isothermal processes was suppressed with TiO 2 addition.From the TTT curves,it could be seen that the incubation and growth time of crystallization increased significantly with TiO 2 addition.The CCT curves showed that the crystallization temperature initially decreased,and then suddenly increased with increasing the TiO 2 content.XRD analysis suggested the presence of cuspidine in the mold fluxes with lower TiO 2 content (< 4 mass%),while both perovskite and cuspidine were detected in the mold fluxes when the TiO 2 content was increased to 8 mass%.In addition,the growth mechanisms of the crystals changed during the isothermal crystallization process from interface-controlled growth to diffusion-controlled growth with increasing the TiO 2 content.

  2. Sensory signals of unloading in one leg follow stance onset in another leg: transfer of load and emergent coordination in cockroach walking.

    Science.gov (United States)

    Zill, Sasha N; Keller, Bridget R; Duke, Elizabeth R

    2009-05-01

    The transfer of load from one leg to another is an essential component in walking, but sense organs that signal this process have rarely been identified. We used high-speed digital imaging and neurophysiological recordings to characterize activities of tibial campaniform sensilla, receptors that detect forces via cuticular strains, in the middle legs of cockroaches during walking. Previous studies demonstrated that the distal tibial sensilla discharge when body load is suddenly decreased in freely standing animals. Sensory recordings during walking showed that distal receptors in the middle leg fired an intense burst near the end of the stance phase. We tested the hypothesis that initiation of distal firing resulted from the action of other legs entering stance. Analysis of leg movements in slow walking showed that sensory bursts in the middle leg closely followed stance onset of the ipsilateral hind leg while the ipsilateral front leg entered stance earlier in phase. Similar phases of leg movement were found in slow walking in experiments in which animals had no implanted recording wires. Those studies also demonstrated that the opposite middle leg entered stance earlier in phase. Measurements of leg positions in walking showed that the hind leg tarsus was placed closest to the middle leg, in keeping with a "targeting" strategy. Triggering of distal bursts in the middle leg by mechanical action of the hind leg could facilitate the onset of swing in the middle leg through local reflex effects and contribute to emergent coordination of leg movements in metachronal gaits.

  3. Klinefelter's syndrome presenting with leg ulcers.

    Science.gov (United States)

    De Morentin, Helena Martinez; Dodiuk-Gad, Roni P; Brenner, Sarah

    2004-01-01

    A 54-year-old man of Persian origin presented to our department with a 1-year history of ulcers on the right leg that had been unresponsive to numerous topical treatments, accompanied by lymphedema of the right leg. Medical history included hypergonadotropic hypogonadism, which had not been further investigated. He was treated for 20 years with testosterone IM once monthly, which he stopped a year before the current hospitalization for unclear reasons. The patient reported no congenital lymphedema. Physical examination revealed two deep skin ulcers (Figure 1) on the right leg measuring 10 cm in diameter with raised irregular inflammatory borders and a boggy, necrotic base discharging a purulent hemorrhagic exudate. Bilateral leg pitting edema and right lymphangitis with lymphadenitis were noted. He had low head hair implantment, sparse hair on the body and head, hyperpigmentation on both legs, onychodystrophia of the toenails (mainly the large toe and less prominent on the other toes), which was atrophic lichen-planus-like in appearance and needed no trimming (Figure 2), normal hand nails, oral thrush, and angular cheilitis. Other physical findings were gynecomastia, pectus excavatum, small and firm testicles, long extremities, asymmetrical goiter, systolic murmur 2/6 in left sternal border, and slow and inappropriate behavior. The patient's temperature on admission was 39 degrees C. Blood cultures were negative for bacterial growth. Results of laboratory investigations included hemoglobin (11.2 g/dL), hematocrit (26.8%), normal mean corpuscular volume and mean corpuscular hemoglobin volume, and red blood cell distribution width (16%). Blood smear showed spherocytes, slight hypochromia, anisocytosis, macrocytosis, and microcytosis. Blood chemistry values were taken for iron (4 micro g/dL [normal range 40-150 micro g/dL]), transferrin (193 mg/dL [normal range 220-400 mg/dL]), ferritin (1128 ng/mL [normal range 14-160 ng/mL]), transferrin saturation (1.5% [normal

  4. Standard guide for use of thermocouples in creep and stress-rupture testing to 1800°F (1000°C) in air

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers the use of ANSI thermocouple Types K, N, R, and S for creep and stress-rupture testing at temperatures up to 1800°F (1000°C) in air at one atmosphere of pressure. It does not cover the use of sheathed thermocouples. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Application of Thermocouple of Float Glass Hot End%浮法玻璃热端热电偶的应用

    Institute of Scientific and Technical Information of China (English)

    刘敏; 张云光; 田万春

    2014-01-01

    该文根据热电偶的实际工作环境及其相关元件特点,对热电偶进行了合理选择及补偿导线操作,确保了安装及接线正确,从而进一步降低了热电偶的测量误差,提高了玻璃的质量。%According to the actual environment and component characteristics,this paper choose thermocouple and compensation wire,install equipment and wire reasonably,avoid external factors,reduce the thermocouple feedback the measurement error and improve the quality of glass.

  6. Errors Analysis of Fluid Medium Temperature Measurement by Thermocouple%用热电偶测量流体介质温度的误差分析

    Institute of Scientific and Technical Information of China (English)

    尹君驰; 薛风

    2014-01-01

    在工业应用中,普遍采用热电偶传感器来进行温度测量。讨论了热电偶在测量温度过程中,由于热传导和热辐射的作用,使其测量误差存在的影响因素,并就提高测量精度介绍了一些措施和几种有针对性的改进热电偶装置。%The thermocouple sensor has been widely used to determine temperature in the industry. In this paper, the factors causing errors in measuring temperature due to heat transmission and radiation were discussed, and some methods to promote measurement accuracy were introduced as well as several improved thermocouple equipments.

  7. Application of high temperature thermocouple in tar gasifier%高温热电偶在焦油气化炉上的应用

    Institute of Scientific and Technical Information of China (English)

    张鸿飞; 王义生

    2016-01-01

    合成气装置气化炉高温热电偶在实际使用过程中寿命较短。文中从工艺、设备、操作参数等方面分析了热电偶易损坏的原因,提出了延长热电偶使用寿命的具体方案,为气化炉的安全平稳长周期运行提供了保障。%Because the service life of the gasifier temperature thermocouple is short,this paper analyzed the cause of the damage of thermocouple from the process,equipment,operating parameters and so on,and put forward the specific solutions to extending of service life,which provided guarantee for the safe and smooth operation of the gasifier.

  8. 铠装热电偶两种校准方法的比较%The comparison of two calibration methods of Sheathed thermocouple

    Institute of Scientific and Technical Information of China (English)

    朱欣贇; 郑伟; 龚宝妹; 张雪峰

    2014-01-01

    通过JJG 351-1996与JJF 1262-2010两种方法对8支铠装K型热电偶进行测试,分析得出后者方法的复现性更佳,不确定度更小,更符合铠装廉金属热电偶的固有特性。%In this article, we calibrate 8 K type Sheathed thermocouples according to JJG 351-1996“Verification Regulation of Working Base Metal Thermocouple”and JJF 1262-2010“Calibration Spectification for Sheathed Thermocouples”. The research results indicate that the latter method gets better Reproducibility and smaller Uncertainty. So the latter method is better for the calibration of sheathed thermocouple.

  9. 镍铬-镍硅热电偶老化失效机理初探%Primary study of nickel chromium-nickel silicon thermocouple aging failure mechanism

    Institute of Scientific and Technical Information of China (English)

    谌立新; 郭卫芳; 陈东

    2011-01-01

    In this paper,the oxidation of nickel chromium-nickel silicon thermocouple after 605h aging failure test in the atmosphere in 1200℃ was carried out and the oxidation process was analysed,and that the priority oxidation of the Si and Ni in the nickel-silicon alloy is main cause of the tolerance of nickel chromium-nickel silicon thermocouple thermo-electromotive force.%就镍铬-镍硅热电偶在大气中1200℃、605h老化失效试验后的氧化情况进行了分析,对氧化过程进行了探讨,结果表明镍硅合金中的硅和镍的优先氧化是引起镍铬-镍硅热电偶热电动势超差的主要原因。

  10. Trainability of cold induced vasodilation

    NARCIS (Netherlands)

    Daanen, H.A.M.; Raymann, R.J.E.M.; Stoop, M.

    2007-01-01

    Peripheral cold injuries are often reported in mountaineers. Not only low ambient temperatures, but also the hypobaric circumstances are known to be major environmental risk factors. When the fingers are exposed to extreme cold for several minutes, cold induced vasodilation (CIVD) occurs, that is

  11. Trainability of cold induced vasodilation

    NARCIS (Netherlands)

    Daanen, H.A.M.; Raymann, R.J.E.M.; Stoop, M.

    2007-01-01

    Peripheral cold injuries are often reported in mountaineers. Not only low ambient temperatures, but also the hypobaric circumstances are known to be major environmental risk factors. When the fingers are exposed to extreme cold for several minutes, cold induced vasodilation (CIVD) occurs, that is re

  12. 高温热电偶材料PtRh40/PtRh20合金性能研究%Prorerties of PtRh40/PtRh20 High-temperature Thermocouple Wires

    Institute of Scientific and Technical Information of China (English)

    吴保安; 刘庆宾; 陈德茂; 汪建胜; 唐会毅; 陈小军

    2013-01-01

    The long-term using temperature of PtRh40/PtRh20 high-temperature thermocouple wire is 1750℃. PtRh40/PtRh20 is belong to non-standard thermocouple, and mainly applies to measure the aircraft efflux plasma temperature. The influences of annealing temperature on the tensile strength and resistivity of PtRh40 and PtRh20 alloy wires, and the influences of the cold working on tensile strength and vickers hardness of the wires were studied. The results indicated that the tensile strengths increased with the increase of annealing temperature at first, then decreased sharply, finally it is stable forming a platform. The resistivities were increased with the annealing temperature, and the tensile strength and hardness were increased with the cold working. The errors of matching thermoelectric potential of PtRh40- PtRh20 relative to ASTM E1751-2000 standard thermoelectric power is 1℃ at 1200℃, 2℃ at 1500℃, and 1℃ at 1700℃.%  PtRh40/PtRh20高温热电偶长期使用温度为1750℃,主要用于飞机尾焰高温测量,属于非标热电偶,目前国内主要依靠进口。研究了 PtRh40、PtRh20退火温度与合金电阻率、抗拉强度及加工率与抗拉强度、硬度的关系,并测试了PtRh40/PtRh20热电偶热电性能。结果表明:抗拉强度随退火温度的升高先升高再急剧下降,最后稳定在一个平台,两者大约在900℃时抗拉强度降至最低;电阻率均随退火温度升高而升高;抗拉强度与硬度均随加工率的增加而提高;PtRh40/PtRh20配对热电势相对ASTM E1751-2000标准热电势测试结果为在1200℃时误差为1℃,在1500℃时误差2℃,在1700℃时误差1℃。

  13. Design and Implementation of Millivolt Signal Generator for Thermocouples%热电偶毫伏信号发生器的设计与实现

    Institute of Scientific and Technical Information of China (English)

    陈盼辉; 陆古兵; 金传喜; 杨洪立

    2012-01-01

    A millivolt signal generator for thermocouples is designed. Using calculation advantage of LabVIEW, the computer can translate the required temperature into the thermocouples EMF and send it to MCU via USB or serial port. Controlled with the MCU, a 12-bit DAC could generate the voltage accordingly. The testing shows that this design can easily achieve millivolt signal generator for a variety of types of thermocouple, and improve the efficiency of the thermocouple instrument calibration, with the accuracy of ± 0. 1 ℃ for general occasions. It can adjust the range of temperature and supporting multiple independent output.%设计了一种热电偶毫伏信号发生器,利用上位机软件LabVIEW的计算优势,将所需的温差转化为相应的热电动势大小,并通过USB或串口发送到单片机,由单片机控制12位DAC转换电路输出相应的电压.测试表明,采用此种方法可以方便地实现多种类型的热电偶信号产生,精度可达±0.1℃,适用于一般的热电偶测量仪表的校准,并且可以根据需要对温度范围进行调节,同时支持多路独立输出,提高了校准效率.

  14. A new manufacture process of Cu-CuNi fine thermocouple%铜-康铜微细热电偶制作新工艺

    Institute of Scientific and Technical Information of China (English)

    周艳; 孙兴华; 钱北行

    2012-01-01

    热电偶是航天器真空热试验中应用最广泛的温度传感器,它的制作工艺决定了其产品的质量和可靠性.文章以铜-康铜微细热电偶的制作工艺为例,提出并实现了一种在惰性气体保护条件下利用高压放电技术进行热电偶焊接制作的工艺方法.这种方法具有操作简单、成品率高的特点,极大提高了热电偶的制作效率,并且解决了热电偶制作过程中因氧化而引入第三种材质的问题.%The thermocouple is the most widely used temperature sensor in the vacuum thermal tests of spacecraft. Its manufacturing process directly affects the product quality and reliability. Taking the manufacturing process of Cu-CuNi fine thermocouple as an example, this paper proposes and has realized a new method to complete the welding of thermocouple by the high-pressure discharge technique under the protection of inert gas. This method is characterized by easier operation and higher rate of acceptability, which greatly improves the efficiency of thermocouple's manufacturing. Besides, the problem of introducing another material during the manufacturing process is avoided.

  15. A Brief Analysis of Technical Requirement Thermocouple in NADCAP Accreditation%浅析 NADCAP 认证中热电偶的技术要求

    Institute of Scientific and Technical Information of China (English)

    马青松

    2016-01-01

    AMS2750标准规定了热处理过程热加工设备的高温测量要求,它包括温度传感器(一般指热电偶)、仪器、热加工设备、系统精度测试和温度均匀型测试五个部分。而热电偶技术要求是高温测量的最重要的内容,本文就热电偶的技术要求对 NADCAP 认证过程中以及日常使用维护中容易存在和忽视的问题进行了剖析。%AMS2750 covers pyrometry requirements for thermal processing equipment used for heat treatment. It covers temperature sensor (commonly thermocouple), instrumentation, thermal processing equipment, system accuracy tests and temperature uniformity surveys. Thermo-couple application plays most important role in pyrometry. analyses the problems familiar and neglected thermocouple in NADCAP accreditaton and in daily use and maintenance.

  16. The application of wolfram thermocouple in spacecraft thermal test%钨铼热电偶在航天器真空热试验中的应用

    Institute of Scientific and Technical Information of China (English)

    安万庆; 柳晓宁; 赵翔宇; 朱熙

    2016-01-01

    目前国内在航天器热试验温度测量方面还没有开展超过1400℃的超高温测量技术研究。文章基于航天器热试验常用热电偶测温原理,分析了钨铼热电偶的结构及制造工艺,并搭建一套热试验测量系统以验证其在航天器真空热试验温度测量系统中的应用。试验结果及数据分析表明,在真空低温环境下钨铼热电偶能够实现1600℃温度测量。%The temperature has not exceeded 1400℃ in the spacecraft thermal test in our country. Based on the principles of the commonly used thermocouple, the structure and the manufactural techniques of the wolfram thermocouple are analyzed, and a measurement system is developed. The application results of the wolfram thermocouple in a spacecraft vacuum thermal test show that it can meet the temperature measurement requirement of 1600℃ in the vacuum thermal environment.

  17. 铠装热电偶校准用精密热电偶校验炉%Precise Calibration Furnace for Sheathed Thermocouples

    Institute of Scientific and Technical Information of China (English)

    王震森; 乔辉; 曹福宾

    2012-01-01

    To satisfy the lately published calibration regulation for sheathed thermocouples, the precise thermocouple calibration furnace has been developed. By adopting the interior and exterior two-stage temperature control and installation mode of the thermometer wells, the calibration furnace offers excellent technical performance. The practice indicates that the furnace can be used in calibration of Grade I industrial thermocouples.%为满足最新颁布的铠装热电偶校准规范对校准用校验炉的要求,研发了精密热电偶校验炉.运用内外二级温度控制及插孔安装方式,使校验炉在进行热电偶校准时具备极佳的技术性能.实际应用表明,精密热电偶校验炉完全可以应用于Ⅰ级工业热电偶的校准.

  18. Treatment of sickle cell leg ulcers with pentoxifylline.

    Science.gov (United States)

    Frost, M L; Treadwell, P

    1990-06-01

    A 58-year-old black man with leg ulcers of 43 years duration responded to pentoxifylline 400 mg tid in 8 months. The ability of pentoxifylline to increase erythrocyte flexibility and decrease blood viscosity was the basis for our use of this agent. Oral pentoxifylline may be a useful adjunct in healing sickle cell leg ulcers and preventing their recurrence.

  19. A Brief Survey Paper on Multi-Legged Robots

    Directory of Open Access Journals (Sweden)

    Mohammad Behmanesh

    2015-03-01

    Full Text Available This paper presents a brief survey on multi-legged robots and their applications in agriculture such as for harvesting. Multi-legged robots have the benefit of more flexibility and adapt to different rough terrain in a better way. They also have very important applications in fulfilling the dangerous tasks such as mine detecting.

  20. Ubx Regulates Differential Enlargement and Diversification of Insect Hind Legs

    Science.gov (United States)

    Mahfooz, Najmus; Turchyn, Nataliya; Mihajlovic, Michelle; Hrycaj, Steven; Popadić, Aleksandar

    2007-01-01

    Differential enlargement of hind (T3) legs represents one of the hallmarks of insect evolution. However, the actual mechanism(s) responsible are yet to be determined. To address this issue, we have now studied the molecular basis of T3 leg enlargement in Oncopeltus fasciatus (milkweed bug) and Acheta domesticus (house cricket). In Oncopeltus, the T3 tibia displays a moderate increase in size, whereas in Acheta, the T3 femur, tibia, and tarsus are all greatly enlarged. Here, we show that the hox gene Ultrabithorax (Ubx) is expressed in the enlarged segments of hind legs. Furthermore, we demonstrate that depletion of Ubx during embryogenesis has a primary effect in T3 legs and causes shortening of leg segments that are enlarged in a wild type. This result shows that Ubx is regulating the differential growth and enlargement of T3 legs in both Oncopeltus and Acheta. The emerging view suggests that Ubx was co-opted for a novel role in regulating leg growth and that the transcriptional modification of its expression may be a universal mechanism for the evolutionary diversification of insect hind legs. PMID:17848997

  1. Restless Legs Syndrome -- Self-Tests and Diagnosis

    Science.gov (United States)

    ... Overview & Facts Causes & Symptoms Self-Tests & Diagnosis Treatment Restless Legs Syndrome - Self-Tests & Diagnosis Self-Tests Do you have ... to any of these questions you may have restless legs syndrome Diagnosis Talk to a board certified sleep medicine ...

  2. Criteria in diagnosing nocturnal leg cramps : a systematic review

    NARCIS (Netherlands)

    Hallegraeff, Joannes; de Greef, Mathieu; Krijnen, Wim; van der Schans, Cees

    2017-01-01

    Background: Up to 33% of the general population over 50 years of age are affected by nocturnal leg cramps. Currently there are no generally accepted clinical characteristics, which identify nocturnal leg cramps. This study aims to identify these clinical characteristics and to differentiate between

  3. Leg strength is associated with ventilatory efficiency in older women.

    Science.gov (United States)

    Gonzales, J U; Tucker, S H; Kalasky, M J; Proctor, D N

    2012-07-01

    The aim of the present study was to determine if leg function is associated with ventilatory efficiency during exercise in healthy older adults. 24 women and 18 men aged 60-80 years performed treadmill exercise to fatigue for calculation of ventilatory efficiency using the ratio of ventilation to carbon dioxide at the anaerobic threshold (VE/VCO₂@AT). On a separate day, participants performed leg strength testing and graded single-leg knee extension exercise. The VE/VCO₂@AT was higher in women than men (33±3 vs. 30±3; p=0.03). After adjustment for age and VO(₂max), leg strength (knee extensor isometric force) was inversely associated with VE/VCO₂@AT in women (r= - 0.44, p=0.03) while no relationships were found for men. Strength-matched women and men had similar VE/VCO₂@AT indicating that the correlation between leg strength and VE/VCO₂@AT was strength- but not sex-specific. During knee extensor exercise, women with lower leg strength had increased VE/VCO₂ slope across 0-15 W as compared to higher strength women (38±8 vs. 31±3; p<0.05), while no differences were found for men. These results find leg strength to be associated with ventilatory responses to exercise in healthy older women, a finding that might be related to lower leg strength in women than men.

  4. X-Ray Exam: Lower Leg (Tibia and Fibula)

    Science.gov (United States)

    ... 2-Year-Old X-Ray Exam: Lower Leg (Tibia and Fibula) KidsHealth > For Parents > X-Ray Exam: Lower Leg (Tibia and Fibula) A A A What's in this ... Child If You Have Questions en español Radiografía: tibia y peroné What It Is An X-ray ...

  5. Beengebrekenonderzoek bij varkens = Research on leg weakness / osteochondrosis in swine

    NARCIS (Netherlands)

    Wal, van der P.G.

    1983-01-01

    Uit onderzoek bleek dat leg weakness, de uiterlijke verschijnselen van beengebreken, niet het resultaat is van osteochondrosis, een verstoring van het verbeningsproces van kraakbeen. De ontwikkeling van de symptomen van leg weakness kunnen onderdrukt worden door natriumbicarbonaat aan het voer toe

  6. Leg length, sitting height and postmenopausal breast cancer risk

    DEFF Research Database (Denmark)

    Mellemkjær, L; Christensen, J; Frederiksen, K

    2012-01-01

    Tallness has consistently been associated with an increased risk of breast cancer. We investigated the association further by decomposing height into leg length and sitting height.......Tallness has consistently been associated with an increased risk of breast cancer. We investigated the association further by decomposing height into leg length and sitting height....

  7. Ubx regulates differential enlargement and diversification of insect hind legs.

    Directory of Open Access Journals (Sweden)

    Najmus Mahfooz

    Full Text Available Differential enlargement of hind (T3 legs represents one of the hallmarks of insect evolution. However, the actual mechanism(s responsible are yet to be determined. To address this issue, we have now studied the molecular basis of T3 leg enlargement in Oncopeltus fasciatus (milkweed bug and Acheta domesticus (house cricket. In Oncopeltus, the T3 tibia displays a moderate increase in size, whereas in Acheta, the T3 femur, tibia, and tarsus are all greatly enlarged. Here, we show that the hox gene Ultrabithorax (Ubx is expressed in the enlarged segments of hind legs. Furthermore, we demonstrate that depletion of Ubx during embryogenesis has a primary effect in T3 legs and causes shortening of leg segments that are enlarged in a wild type. This result shows that Ubx is regulating the differential growth and enlargement of T3 legs in both Oncopeltus and Acheta. The emerging view suggests that Ubx was co-opted for a novel role in regulating leg growth and that the transcriptional modification of its expression may be a universal mechanism for the evolutionary diversification of insect hind legs.

  8. Ontogenetic shifts in functional morphology of dragonfly legs (Odonata: Anisoptera).

    Science.gov (United States)

    Leipelt, Klaus Guido; Suhling, Frank; Gorb, Stanislav N

    2010-12-01

    Anisopteran leg functions change dramatically from the final larval stadium to the adult. Larvae use legs mainly for locomotion, walking, climbing, clinging, or burrowing. Adults use them for foraging and grasping mates, for perching, clinging to the vegetation, and for repelling rivals. In order to estimate the ontogenetic shift in the leg construction from the larva to the adult, this study quantitatively compared lengths of fore, mid, and hind legs and the relationships between three leg segments, femur, tibia, and tarsus, in larval and adult Anisoptera of the families Gomphidae, Aeshnidae, Cordulegastridae, Corduliidae, and Libellulidae, represented by two species each. We found that leg segment length ratio as well as ontogenetic shift in length ratios was different between families, but rather similar within the families. While little ontogenetic shift occurred in Aeshnidae, there were some modifications in Corduliidae and Libellulidae. The severest shift occurred in Gomphidae and Cordulegastridae, both having burrowing larvae. These two families form a cluster, which is in contrast to their taxonomic relationship within the Anisoptera. Cluster analysis implies that the function of larval legs is primarily responsible for grouping, whereas adult behavior or the taxonomic relationships do not explain the grouping. This result supports the previous hypothesis about the convergent functional shift of leg characters in the dragonfly ontogenesis.

  9. Impact of Restless Legs Syndrome on Cardiovascular Autonomic Control.

    Science.gov (United States)

    Bertisch, Suzanne M; Muresan, Cristen; Schoerning, Laura; Winkelman, John W; Taylor, J Andrew

    2016-03-01

    To examine whether patients with restless legs syndrome demonstrate specific alterations in cardiovascular autonomic control. Patients with moderate-severe restless legs syndrome (n = 20, 80% female) and controls (n = 20) matched for age, sex, body mass index, and free of hypertension and cardiovascular disease were enrolled. We assessed cardiovagal baroreflex gain via the modified Oxford technique, sympathetically mediated vascular responses to isometric exercise to fatigue, bradycardiac response to Valsalva maneuver, and respiratory sinus arrhythmia during paced breathing. Standard electrocardiography, beat-by-beat arterial pressure, respiration, and popliteal blood flow velocity were recorded continuously. Resting blood pressure and heart rate were similar between groups. However, baroreflex gain averaged 14.3 ± 1.4 msec/mm Hg in restless legs syndrome and was lower than in controls (22.6 ± 3.5 msec/mm Hg, P = 0.04). Hemodynamic responses to isometric exercise were similar between groups, though participants with restless legs syndrome had lower leg blood flow (P leg vascular resistance (P legs syndrome demonstrate compromised cardiovagal control, specific to the arterial baroreflex, with greater peripheral vascular resistance, potentially due to heightened sympathetic outflow. These autonomic alterations may directly relate to the higher prevalence of cardiovascular disease in restless legs syndrome. © 2016 Associated Professional Sleep Societies, LLC.

  10. The recalcitrant venous leg ulcer - A never ending story?

    NARCIS (Netherlands)

    S.W.I. Reeder (Suzan); M.B. Maessen-Visch (Birgitte); S.I. Langendoen; K.P. de Roos; H.A.M. Neumann (Martino)

    2013-01-01

    textabstractIntroduction: In general, four particular causes of recalcitrant venous leg ulcers may be distinguished. These are foot pump insufficiency, chronic venous compartment syndrome and non-re-canalized popliteal vein thrombosis. The fourth cause of recalcitrant venous leg ulcers is lipodermat

  11. Restless legs syndrome in opioid dependent patients

    Directory of Open Access Journals (Sweden)

    Abhishek Ghosh

    2014-01-01

    Full Text Available Although frequently underdiagnosed, several epidemiological studies have estimated the prevalence of restless legs syndrome (RLS in western countries at 5-15% of the general population. The diagnosis is usually made on a clinical basis, according to the criteria established by the international RLS study group. There are case reports of transient RLS in opiate withdrawal. We describe three opiate (dextropropoxyphene (DPP dependent young male patients; two of them had DPP intoxication/withdrawal seizure developing RLS during opiate withdrawal. However, their RLS persisted even after the remission of other withdrawal symptoms. Thyroid function test, hemogram, serum ferritin were normal in all of them. The cases responded well to a treatment with ropinirole. Hence, there might be a causal association, which required further well-designed studies to substantiate. The sleep disturbances and use of benzodiazepines can be minimized by increasing clinician′s sensitivity to diagnose RLS.

  12. Series Elastic Actuators for legged robots

    Science.gov (United States)

    Pratt, Jerry E.; Krupp, Benjamin T.

    2004-09-01

    Series Elastic Actuators provide many benefits in force control of robots in unconstrained environments. These benefits include high force fidelity, extremely low impedance, low friction, and good force control bandwidth. Series Elastic Actuators employ a novel mechanical design architecture which goes against the common machine design principal of "stiffer is better." A compliant element is placed between the gear train and driven load to intentionally reduce the stiffness of the actuator. A position sensor measures the deflection, and the force output is accurately calculated using Hooke"s Law (F=Kx). A control loop then servos the actuator to the desired output force. The resulting actuator has inherent shock tolerance, high force fidelity and extremely low impedance. These characteristics are desirable in many applications including legged robots, exoskeletons for human performance amplification, robotic arms, haptic interfaces, and adaptive suspensions. We describe several variations of Series Elastic Actuators that have been developed using both electric and hydraulic components.

  13. Acute Compartment Syndrome of the Leg.

    Science.gov (United States)

    Konda, Sanjit R; Kester, Benjamin S; Fisher, Nina; Behery, Omar A; Crespo, Alexander M; Egol, Kenneth A

    2017-08-01

    Acute compartment syndrome (ACS) is well known among orthopaedic surgeons. The timely diagnosis and management of ACS is crucial to avoiding its sequelae, including renal failure, ischemic contractures, and limb loss. Despite its relative importance, ACS poses a challenge to many residents and clinicians as diagnosis relies largely on clinical judgment. Timely diagnosis and thorough compartment release are essential to optimizing outcomes in ACS. This video highlights a clinical case in which compartment syndrome of the leg was considered, diagnosed, and surgically managed. This video will present the indications for compartment release and a video-guided demonstration of compartment checks using an arterial line transducer, a 4-compartment fasciotomy with 2 incisions, and temporizing vessel loop closure. Compartment syndrome can be a devastating complication of common fractures. It is essential that orthopaedic practitioners understand the immediacy of intervention. We have a responsibility to provide timely, accurate diagnosis along with expedient surgical management.

  14. Integrated design of legged mechatronic system

    Institute of Scientific and Technical Information of China (English)

    ChinYin CHEN; IMing CHEN; ChiCheng CHENG

    2009-01-01

    This paper presents a system based on the integrated design and experiment for a one degree-of-freedom (DOF) legged mechatronic system (LMTS). A six-bar linkage mechanism, which is derived from a four-bar linkage with a symmetrical coupler point and pantograph into one, is designed, and common controllers are used to control the velocity and position loops.For system-based dynamic optimization, the design for control (DFC) approach is used to integrate the structure and control for improving dynamic performance with reduced control torque.Finally, for a rapid 3D graphical based implementation of the system, high-level computer-aided rapid system integration (CARSI) technology is used to integrate the structure design, controller design, and system implemen-tation into the design and analytical software environment based on Pro/engineer, XML syntax, Simmechanics, and Simulink. Thus, the development time for the LMTS is reduced.

  15. WISPy cold dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Arias, Paola [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Cadamuro, Davide; Redondo, Javier [Max-Planck-Institut fuer Physik, Muenchen (Germany); Goodsell, Mark [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Jaeckel, Joerg [Durham Univ. (United Kingdom). Inst. for Particle Physics Phenomenology; Ringwald, Andreas [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2012-01-15

    Very weakly interacting slim particles (WISPs), such as axion-like particles (ALPs) or hidden photons (HPs), may be non-thermally produced via the misalignment mechanism in the early universe and survive as a cold dark matter population until today. We find that, both for ALPs and HPs whose dominant interactions with the standard model arise from couplings to photons, a huge region in the parameter spaces spanned by photon coupling and ALP or HP mass can give rise to the observed cold dark matter. Remarkably, a large region of this parameter space coincides with that predicted in well motivated models of fundamental physics. A wide range of experimental searches - exploiting haloscopes (direct dark matter searches exploiting microwave cavities), helioscopes (searches for solar ALPs or HPs), or light-shining-through-a-wall techniques - can probe large parts of this parameter space in the foreseeable future. (orig.)

  16. "Miniature Cold War?"

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ Fu: Relations between America and Russia are one of the most important bilateral ties that could affect the trend of world situation.What's the matter with U. S. -Russia ties? What's wrong with their bilateral relations? People tend to ask these days. Some observers on both sides suggest that post 9/11 honeymoon has turned sour when joint effort against challenges from nontraditional security issues failed to remove original bilateral contradictions over traditional security concerns.Japanese Jiji News Agency saw "a miniature Cold War" evolving and the British Guardian even bluntly pronounced "a new Cold War" on January 3, asserting that disintegration of the former Soviet Union did not terminate bilateral contention, which has only been performed on an international stage more complicated than ever before, with covert scheming against each other replacing overt, direct confrontation. How about starting our discussion with those comments?

  17. Leg length discrepancy in scoliotic patients.

    Science.gov (United States)

    D'Amico, Moreno; Roncoletta, Piero; Di Felice, Francesca; Porto, Daniele; Bellomo, Rosagrazia; Saggini, Raoul

    2012-01-01

    The aetiological aspects as well as postural attitude implications represent an open question in scoliosis evaluation and treatment. Leg length discrepancy (LLD) is often recognised in scoliotic patients, but surprisingly still controversial is the use of underfoot wedge corrections in order to compensate pelvis tilt. In fact, literature reports conflicting results on the efficacy of LLD equalization also given the argued uncertainty of LLD clinical assessment and limitations related to X-ray measurements. Moreover concern is about anatomic and functional LLD and associated estimation of the pelvic torsion. In such a topic, a significant helpful tool has been demonstrated to be 3D kinematic optoelectronic measurements and other useful data obtained from force platforms and/or baropodographic systems. 135 (94.4%) out of 143 Scoliotic patients sample (av. age 16.4±10.2 Y range 4-66 Y), have been found to improve posture when LLD was corrected. The 143 patients showed a mean lower limb discrepancy of μ=10.2±5.2mm associated to a mean main scoliotic curve μ=16.4°±9.4° Cobb (frontal plane), mean Spinal offset μ=7.5±5.5mm and mean Global offset μ=10.1±7.1mm. The applied paired t-test comparison (indifferent vs. corrected orthostasis) showed significant (p < 0.05) postural improvements could be obtained in the whole or in a part of the considered postural parameters, after the application of suitable under-foot wedge. The present investigation confirm results of a previous study demonstrating the efficacy of under-foot wedge use in leg asymmetry correction, posture re-balancing and spine deformities reduction, pointing out the significant contribution of the 3D opto-electronic measurement approach in the critical process of assessing the correct under-foot wedge size, therapy planning and monitoring.

  18. Restless legs syndrome in patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Saleh Mohammad Yaser Salman

    2011-01-01

    Full Text Available Restless legs syndrome (RLS is common among dialysis patients, with a reported prevalence of 6-60%. The prevalence of RLS in Syrian patients on hemodialysis (HD is not known. The purpose of this study is to determine the prevalence of RLS in patients on regular HD, and to find the possible correlation between the presence of RLS and demographic, clinical, and biochemical factors. One hundred and twenty-three patients (male/female = 70/53, mean age = 41.95 ± 15.11 years on HD therapy at the Aleppo University Hospital were enrolled into the study. RLS was diagnosed based on criteria established by the International Restless Legs Syn-drome Study Group (IRLSSG. Data procured were compared between patients with and without RLS. Applying the IRLSSG criteria for the diagnosis, RLS was seen in 20.3% of the study pa-tients. No significant difference in age, gender, and intake of nicotine and caffeine was found between patients with and without the RLS. Similarly, there was no difference between the two groups in the duration of end-stage renal disease (ESRD, the period of dialysis dependence, dialysis adequacy, urea and creatinine levels, and the presence of anemia. The co-morbidities and the use of drugs also did not differ in the two groups. Our study suggests that the high prevalence of RLS among patients on HD requires careful attention and correct diagnosis can lead to better therapy and better quality of life. The pathogenesis of RLS is not clear and further studies are required to identify any possible cause as well as to discover the impact of this syndrome on sleep, quality of life, and possibly other complications such as cardiovasculare disease.

  19. Restless legs syndrome in patients on hemodialysis.

    Science.gov (United States)

    Salman, Saleh Mohammad Yaser

    2011-03-01

    Restless legs syndrome (RLS) is common among dialysis patients, with a reported prevalence of 6-60%. The prevalence of RLS in Syrian patients on hemodialysis (HD) is not known. The purpose of this study is to determine the prevalence of RLS in patients on regular HD, and to find the possible correlation between the presence of RLS and demographic, clinical, and biochemical factors. One hundred and twenty-three patients (male/female = 70/53, mean age = 41.95 ± 15.11 years) on HD therapy at the Aleppo University Hospital were enrolled into the study. RLS was diagnosed based on criteria established by the International Restless Legs Syn-drome Study Group (IRLSSG). Data procured were compared between patients with and without RLS. Applying the IRLSSG criteria for the diagnosis, RLS was seen in 20.3% of the study pa-tients. No significant difference in age, gender, and intake of nicotine and caffeine was found between patients with and without the RLS. Similarly, there was no difference between the two groups in the duration of end-stage renal disease (ESRD), the period of dialysis dependence, dialysis adequacy, urea and creatinine levels, and the presence of anemia. The co-morbidities and the use of drugs also did not differ in the two groups. Our study suggests that the high prevalence of RLS among patients on HD requires careful attention and correct diagnosis can lead to better therapy and better quality of life. The pathogenesis of RLS is not clear and further studies are required to identify any possible cause as well as to discover the impact of this syndrome on sleep, quality of life, and possibly other complications such as cardiovasculare disease.

  20. Short-interval leg movements during sleep entail greater cardiac activation than periodic leg movements during sleep in restless legs syndrome patients.

    Science.gov (United States)

    Ferri, Raffaele; Rundo, Francesco; Silvani, Alessandro; Zucconi, Marco; Aricò, Debora; Bruni, Oliviero; Lanuzza, Bartolo; Ferini-Strambi, Luigi; Manconi, Mauro

    2017-10-01

    Periodic leg movements during sleep (PLMS) are sequences of ≥4 motor events with intermovement intervals (IMI) of 10-90 s. PLMS are a supportive diagnostic criterion for restless legs syndrome (RLS) and entail cardiac activation, particularly when associated with arousal. RLS patients also over-express short-interval leg movements during sleep (SILMS), which have IMI leg movements. We found that the duration of the R-R interval decrease with SILMS doublets was significantly longer than that with PLMS, whereas the maximal decrease in R-R interval was similar. Scoring SILMS in RLS patients may therefore be relevant from a cardiac autonomic perspective. © 2017 European Sleep Research Society.

  1. Engine Cold Start

    Science.gov (United States)

    2015-09-01

    14. ABSTRACT These fuels were used for testing a GEP 6.5L turbocharged V-8 diesel engine operation in a cold box. This engine architecture is... engines . The U.S. military currently uses petroleum-based jet fuels in diesel engine -powered ground vehicles and is studying the use of alternative jet...to identify a window, or range, of cetane number which would be acceptable to ensure the reliable operation of diesel engine -powered military ground

  2. Electronic Equipment Cold Plates

    Science.gov (United States)

    1976-04-01

    equations for such a flow regiae. For laainar flow and Moderate teaperature differwwe« between the well «nd coolant, a aodifled Sieder -Tate...con- figuration. The heat-transfer coefficients, therefore, were determined by using both the Sieder -Tate and McAdams equations and the coaputed...values used In the analytical predictions. As with th* previous cold Plates, the Sieder -Tate equation gave too low of values for the heat- transfer

  3. The CMS COLD BOX

    CERN Multimedia

    Brice, Maximilien

    2015-01-01

    The CMS detector is built around a large solenoid magnet. This takes the form of a cylindrical coil of superconducting cable that generates a field of 3.8 Tesla: about 100,000 times the magnetic field of the Earth. To run, this superconducting magnet needs to be cooled down to very low temperature with liquid helium. Providing this is the job of a compressor station and the so-called “cold box”.

  4. A Terradynamics of Legged Locomotion on Granular Media

    CERN Document Server

    Li, Chen; Goldman, Daniel I; 10.1126/science.1229163

    2013-01-01

    The theories of aero- and hydrodynamics predict animal movement and device design in air and water through the computation of lift, drag, and thrust forces. Although models of terrestrial legged locomotion have focused on interactions with solid ground, many animals move on substrates that flow in response to intrusion. However, locomotor-ground interaction models on such flowable ground are often unavailable. We developed a force model for arbitrarily-shaped legs and bodies moving freely in granular media, and used this "terradynamics" to predict a small legged robot's locomotion on granular media using various leg shapes and stride frequencies. Our study reveals a complex but generic dependence of stresses in granular media on intruder depth, orientation, and movement direction and gives insight into the effects of leg morphology and kinematics on movement.

  5. Adaptive leg coordination with a biologically inspired neurocontroller

    Science.gov (United States)

    Braught, Grant; Thomopoulos, Stelios C.

    1996-10-01

    Natural selection is responsible for the creation of robust and adaptive control systems. Nature's control systems are created only from primitive building blocks. Using insect neurophysiology as a guide, a neural architecture for leg coordination in a hexapod robot has been developed. Reflex chains and sensory feedback mechanisms from various insects and crustacea form the basis of a pattern generator for intra-leg coordination. The pattern generator contains neural oscillators which learn from sensory feedback to produce stepping patterns. Using sensory feedback as the source of learning information allows the pattern generator to adapt to changes in the leg dynamics due to internal or external causes. A coupling between six of the single leg pattern generators is used to produce the inter-leg coordination necessary to establish stable gaits.

  6. Why do arms extract less oxygen than legs during exercise?

    DEFF Research Database (Denmark)

    Calbet, J A L; Holmberg, H-C; Rosdahl, H;

    2005-01-01

    To determine whether conditions for O2 utilization and O2 off-loading from the hemoglobin are different in exercising arms and legs, six cross-country skiers participated in this study. Femoral and subclavian vein blood flow and gases were determined during skiing on a treadmill at approximately 76......% maximal O2 uptake (V(O2)max) and at V(O2)max with different techniques: diagonal stride (combined arm and leg exercise), double poling (predominantly arm exercise), and leg skiing (predominantly leg exercise). The percentage of O2 extraction was always higher for the legs than for the arms. At maximal...... exercise (diagonal stride), the corresponding mean values were 93 and 85% (n = 3; P

  7. Detection of Periodic Leg Movements by Machine Learning Methods Using Polysomnographic Parameters Other Than Leg Electromyography

    Directory of Open Access Journals (Sweden)

    İlhan Umut

    2016-01-01

    Full Text Available The number of channels used for polysomnographic recording frequently causes difficulties for patients because of the many cables connected. Also, it increases the risk of having troubles during recording process and increases the storage volume. In this study, it is intended to detect periodic leg movement (PLM in sleep with the use of the channels except leg electromyography (EMG by analysing polysomnography (PSG data with digital signal processing (DSP and machine learning methods. PSG records of 153 patients of different ages and genders with PLM disorder diagnosis were examined retrospectively. A novel software was developed for the analysis of PSG records. The software utilizes the machine learning algorithms, statistical methods, and DSP methods. In order to classify PLM, popular machine learning methods (multilayer perceptron, K-nearest neighbour, and random forests and logistic regression were used. Comparison of classified results showed that while K-nearest neighbour classification algorithm had higher average classification rate (91.87% and lower average classification error value (RMSE = 0.2850, multilayer perceptron algorithm had the lowest average classification rate (83.29% and the highest average classification error value (RMSE = 0.3705. Results showed that PLM can be classified with high accuracy (91.87% without leg EMG record being present.

  8. Effects of gabapentin enacarbil on restless legs syndrome and leg pain in dementia with Lewy bodies.

    Science.gov (United States)

    Fujishiro, Hiroshige

    2014-06-01

    Restless legs syndrome (RLS) is a common neurological disorder. Dementia with Lewy bodies (DLB) is the second most common form of neurodegenerative dementia after Alzheimer's disease. Both RLS and DLB can be effectively treated by dopaminergic medications, suggesting the role of dopamine dysfunction in the pathogenesis of both diseases. Here, I report on a Japanese woman with probable DLB and RLS who was treated with gabapentin enacarbil, a non-dopaminergic agent. Because a dopamine agonist, a first-line therapy for moderate to severe RLS, caused the occurrence of metamorphopsia, an alternative treatment of gabapentin enacarbil was used; this treatment improved the patient's RLS without worsening her psychiatric symptoms. An alternative treatment is desirable for DLB patients with RLS because they often experience intolerable side-effects with a dopamine agonist, especially visual hallucinations. Administering gabapentin enacarbil also improved the continuous leg pain that occurred in conjunction with the development of RLS. Although the neurobiological mechanism in the development of pain remains unclear, a range of non-dopaminergic structures likely mediated pain processing in DLB in the present case based on neuropharmacological results. This is the first report reporting the effects of gabapentin enacarbil for RLS and leg pain in a DLB patient with psychiatric symptoms.

  9. Validation of a leg movements count and periodic leg movements analysis in a custom polysomnography system.

    Science.gov (United States)

    Stefani, Ambra; Heidbreder, Anna; Hackner, Heinz; Högl, Birgit

    2017-02-23

    Periodic leg movements (PLM) during sleep (PLMS) are considered strongly related to restless legs syndrome (RLS), and are associated with polymorphisms in RLS risk genes. Various software for automatic analysis of PLMS are available, but only few of them have been validated. Aim of this study was to validate a leg movements count and analysis integrated in a commercially available polysomnography (PSG) system against manual scoring. Twenty RLS patients with a PLMS index > 20/h and 20 controls with a PLMS index PLM was performed according to the standard American Academy of Sleep Medicine (AASM) criteria. LM and PLM indices during sleep and wakefulness, the rate of PLMS associated with respiratory events, intermovement interval and periodicity indices were manually and automatically scored. The correlation between manual and computerized scoring was high for all investigated parameters (Spearman correlation coefficients 0.751-0.996, p PLM analysis against the gold standard manual scoring according to AASM criteria. The data demonstrate that the software used in this study has an outstanding performance for computerized LM and PLM scoring, and LM and PLM indices generated with this software can be reliably integrated in the routine PSG report. This automatic analysis is also an excellent tool for research purposes.

  10. Investigation into the correlation between sensation and leg movement in restless legs syndrome.

    Science.gov (United States)

    Birinyi, Paul V; Allen, Richard P; Lesage, Susan; Dean, Terry; Earley, Christopher J

    2005-09-01

    We evaluated rest effects on restless legs syndrome (RLS) sensory and motor symptoms. During two 60-minute Suggested Immobilization Tests (SIT) subject's signals of RLS leg sensations and periodic leg movements while awake (PLMW) were recorded. Sensations, PLMW, sensations preceding or after PLMW, sensations occurring without following PLMW, and PLMW occurring without preceding sensation were determined. The RLS patients were divided into equal-sized high and low PLMW groups for further analysis. Data from 46 subjects (28 RLS and 18 controls) revealed sensations increased linearly with rest in RLS patients and controls. Movement rate increased linearly with rest for controls but increased rapidly for the first 45 minutes for all RLS patients. PLMW/hour increased with further rest for low but not high PLMW patients. Sensations followed by PLMW and PLMW without preceding sensations followed similar patterns. Sensations without subsequent PLMW increased dramatically in the last 15 minutes of the SITs. Whereas both sensory and motor signs of RLS increase with rest, there is minimal increase for controls. Patients with higher but not lower PLMW rates reached a ceiling for PLMW after 35 to 40 minutes. The temporal dissociation between sensory and motor events supports viewing these motor and sensory events as separate but loosely linked manifestations of RLS. (c) 2005 Movement Disorder Society.

  11. Leg stiffness and stride frequency in human running.

    Science.gov (United States)

    Farley, C T; González, O

    1996-02-01

    When humans and other mammals run, the body's complex system of muscle, tendon and ligament springs behaves like a single linear spring ('leg spring'). A simple spring-mass model, consisting of a single linear leg spring and a mass equivalent to the animal's mass, has been shown to describe the mechanics of running remarkably well. Force platform measurements from running animals, including humans, have shown that the stiffness of the leg spring remains nearly the same at all speeds and that the spring-mass system is adjusted for higher speeds by increasing the angle swept by the leg spring. The goal of the present study is to determine the relative importance of changes to the leg spring stiffness and the angle swept by the leg spring when humans alter their stride frequency at a given running speed. Human subjects ran on treadmill-mounted force platform at 2.5ms-1 while using a range of stride frequencies from 26% below to 36% above the preferred stride frequency. Force platform measurements revealed that the stiffness of the leg spring increased by 2.3-fold from 7.0 to 16.3 kNm-1 between the lowest and highest stride frequencies. The angle swept by the leg spring decreased at higher stride frequencies, partially offsetting the effect of the increased leg spring stiffness on the mechanical behavior of the spring-mass system. We conclude that the most important adjustment to the body's spring system to accommodate higher stride frequencies is that leg spring becomes stiffer.

  12. 锅炉集汽集箱热电偶套管断裂原因分析%Analysis About the Reason of Thermocouple Casing on Boiler Stream Header Cracking

    Institute of Scientific and Technical Information of China (English)

    张军; 王晓东; 谭伟

    2012-01-01

    Introduced the thermocouple casing on boiler stream header measuring main steam tenperature cannula suddenly breaking;Analyzed the reasons of thermocouple on boiler stream header cracked.%对锅炉集汽集箱测量主蒸汽温度的热电偶套管突然断裂情况进行了说明,并对断裂的原因进行了分析和讨论。

  13. 78 FR 68909 - Agency Information Collection (Knee and Lower Leg Conditions Disability Benefits Questionnaire...

    Science.gov (United States)

    2013-11-15

    ... AFFAIRS Agency Information Collection (Knee and Lower Leg Conditions Disability Benefits Questionnaire... Leg Conditions Disability Benefits Questionnaire)'' in any correspondence. FOR FURTHER INFORMATION... Control No. 2900-NEW (Knee and Lower Leg Conditions Disability Benefits Questionnaire)''....

  14. Single-leg squats can predict leg alignment in dancers performing ballet movements in “turnout”

    Directory of Open Access Journals (Sweden)

    Hopper LS

    2016-11-01

    Full Text Available Luke S Hopper,1 Nahoko Sato,2 Andries L Weidemann1 1Western Australian Academy of Performing Arts, Edith Cowan University, Mt Lawley, WA, Australia; 2Department of Physical Therapy, Nagoya Gakuin University, Seto, Japan Abstract: The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve “turning out” or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in “turned out” postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat. Keywords: injury, motion capture, clinical assessment

  15. Single-leg squats can predict leg alignment in dancers performing ballet movements in “turnout”

    Science.gov (United States)

    Hopper, Luke S; Sato, Nahoko; Weidemann, Andries L

    2016-01-01

    The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve “turning out” or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in “turned out” postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat. PMID:27895518

  16. Artificial Leg Design and Control Research of a Biped Robot with Heterogeneous Legs Based on PID Control Algorithm

    Directory of Open Access Journals (Sweden)

    Hualong Xie

    2015-04-01

    Full Text Available A biped robot with heterogeneous legs (BRHL is proposed to provide an ideal test-bed for intelligent bionic legs (IBL. To make artificial leg gait better suited to a human, a four-bar mechanism is used as its knee joint, and a pneumatic artificial muscle (PAM is used as its driving source. The static mathematical model of PAM is established and the mechanical model of a single degree of freedom of a knee joint driven by PAM is analyzed. A control simulation of an artificial leg based on PID control algorithm is carried out and the simulation results indicate that the artificial leg can simulate precisely a normal human walking gait.

  17. Association of Restless Legs Syndrome Variants in Korean Patients with Restless Legs Syndrome

    Science.gov (United States)

    Kim, Myeong-Kyu; Cho, Yong Won; Shin, Won Chul; Cho, Jae Wook; Shon, Young Min; Kim, Jee Hyun; Yang, Kwang Ik; Earley, Christopher J.; Allen, Richard P.

    2013-01-01

    Study Objectives: Recent genome-wide association studies (GWAS) for Caucasians identified several allelic variants associated with increased risk of developing restless legs syndrome (RLS), also known as Willis-Ekbom disease. Although the pathogenic mechanisms of RLS are not entirely understood, it is becoming increasingly evident that many diseases such as RLS can be attributed to an epistasis. The study objectives were to evaluate whether the associations of RLS with all loci determined in previous GWAS for Caucasians can be replicated significantly for the Korean population and to elucidate whether an epistasis plays a role in the pathogenesis of RLS. Design, Setting, and Participants: DNA from 320 patients with RLS and 320 age- and sex-matched controls were genotyped for variants in the RLS loci. Measurements and Results: A significant association was found for rs3923809 and rs9296249 in BTBD9 (P < 0.0001 and P = 0.001, respectively); the odds ratio (OR) for rs3923809 was 1.61 (P < 0.0001) to 1.88 (P < 0.0001) and the OR for rs9296249 was 1.44 (P = 0.001) to 1.73 (P = 0.002), according to the model of inheritance. The OR for the interaction between rs3923809 in BTBD9 and rs4626664 in PTPRD was 2.05 (P < 0.0001) in the additive model, 1.80 (P = 0.002) in the dominant model and 2.47 (P = 0.004) in the recessive model. There was no significant association between genotypes of all tested single nucleotide polymorphisms and the mean value of serum iron parameters. Conclusions: Our results suggest that the role of BTBD9 in the pathogenesis of restless legs syndrome is more universal across populations than previously reported and more efforts should be focused on the role of epistasis in the genetic architecture of restless legs syndrome. Citation: Kim MK; Cho YW; Shin WC; Cho JW; Shon YM; Kim JH; Yang KI; Earley CJ; Allen RP. Association of restless legs syndrome variants in Korean patients with restless legs syndrome. SLEEP 2013;36(12):1787-1791. PMID:24293752

  18. Leg stiffness primarily depends on ankle stiffness during human hopping.

    Science.gov (United States)

    Farley, C T; Morgenroth, D C

    1999-03-01

    When humans hop in place or run forward, they adjust leg stiffness to accommodate changes in stride frequency or surface stiffness. The goal of the present study was to determine the mechanisms by which humans adjust leg stiffness during hopping in place. Five subjects hopped in place at 2.2 Hz while we collected force platform and kinematic data. Each subject completed trials in which they hopped to whatever height they chose ("preferred height hopping") and trials in which they hopped as high as possible ("maximum height hopping"). Leg stiffness was approximately twice as great for maximum height hopping as for preferred height hopping. Ankle torsional stiffness was 1.9-times greater while knee torsional stiffness was 1.7-times greater in maximum height hopping than in preferred height hopping. We used a computer simulation to examine the sensitivity of leg stiffness to the observed changes in ankle and knee stiffness. Our model consisted of four segments (foot, shank, thigh, head-arms-trunk) interconnected by three torsional springs (ankle, knee, hip). In the model, increasing ankle stiffness by 1.9-fold, as observed in the subjects, caused leg stiffness to increase by 2.0-fold. Increasing knee stiffness by 1.7-fold had virtually no effect on leg stiffness. Thus, we conclude that the primary mechanism for leg stiffness adjustment is the adjustment of ankle stiffness.

  19. Evaluation of Thermoelectric Performance and Durability of Functionalized Skutterudite Legs

    Science.gov (United States)

    Skomedal, Gunstein; Kristiansen, Nils R.; Sottong, Reinhard; Middleton, Hugh

    2017-04-01

    Thermoelectric generators are a promising technology for waste heat recovery. As new materials and devices enter a market penetration stage, it is of interest to employ fast and efficient measurement methods to evaluate the long-term stability of thermoelectric materials in combination with metallization and coating (functionalized thermoelectric legs). We have investigated a method for measuring several thermoelectric legs simultaneously. The legs are put under a common temperature gradient, and the electrical characteristics of each leg are measured individually during thermal cycling. Using this method, one can test different types of metallization and coating applied to skutterudite thermoelectric legs and look at the relative changes over time. Postcharacterization of these initial tests with skutterudite legs using a potential Seebeck microprobe and an electron microscope showed that oxidation and interlayer diffusion are the main reasons for the gradual increase in internal resistance and the decrease in open-circuit voltage. Although we only tested skutterudite material in this work, the method is fully capable of testing all kinds of material, metallization, and coating. It is thus a promising method for studying the relationship between failure modes and mechanisms of functionalized thermoelectric legs.

  20. Restless legs syndrome in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Al-Jahdali Hamdan

    2009-01-01

    Full Text Available Restless legs syndrome (RLS is an extremely distressing problem experienced by patients on dialysis; the prevalence appears to be greater than in the general population, with a wide variation from 6.6% to 80%. The diagnosis of RLS is a clinical one, and its definition has been clarified and standardized by internationally recognized diagnostic criteria, published in 1995 by the International Restless Legs Syndrome Study Group (IRLSSG. This study was designed to find out the prevalence of RLS in Saudi patients with end-stage renal disease (ESRD on maintenance dialysis. This is a cross sectional study carried out between May and Sept 2007 at two centers, King Abdulaziz Medical City-King Fahad National Guard Hospital (KAMC-KFNGH, Riyadh and King Faisal Specialist Hospital and Research Centre (KFHRC, Jeddah, Saudi Arabia. Data were gathered on 227 Saudi patients on chronic maintenance hemodialysis or chronic peritoneal dialysis. The prevalence of RLS was measured using IRLSSG′s RLS Questionnaire (RLSQ. Potential risk factors for RLS including other sleep disorders, underlying cause of chronic renal failure, duration on dialysis, dialysis shift, biochemical tests and demographic data were also evaluated. The overall prevalence of RLS was 50.22% including 53.7% males and 46.3% females. Their mean age was 55.7 ± 17.2 years and mean duration on dialysis 40.4 ± 37.8 months. Significant predictors of RLS were history of diabetes mellitus (DM, coffee intake, afternoon dialysis, gender and type of dialysis (P= 0.03, 0.01, < 0.001, 0.05 and 0.009 respectively. Patients with RLS were found to be at increased risk of having insomnia and excessive daytime sleepiness (EDS (P= < 0.001 and 0.001, respectively. Our study suggests that RLS is a very common problem in dialysis population and was significantly associated with other sleep disorders, particularly insomnia, and EDS. Optimal care of dialysis patient should include particular attention to the diagnosis

  1. Restless legs syndrome in patients on dialysis.

    Science.gov (United States)

    Al-Jahdali, Hamdan H; Al-Qadhi, Waleed A; Khogeer, Haithm A; Al-Hejaili, Fayez F; Al-Ghamdi, Saeed M; Al Sayyari, Abdullah A

    2009-05-01

    Restless legs syndrome (RLS) is an extremely distressing problem experienced by patients on dialysis; the prevalence appears to be greater than in the general population, with a wide variation from 6.6% to 80%. The diagnosis of RLS is a clinical one, and its definition has been clarified and standardized by internationally recognized diagnostic criteria, published in 1995 by the International Restless Legs Syndrome Study Group (IRLSSG). This study was designed to find out the prevalence of RLS in Saudi patients with end-stage renal disease (ESRD) on maintenance dialysis. This is a cross sectional study carried out between May and Sept 2007 at two centers, King Abdulaziz Medical City-King Fahad National Guard Hospital (KAMC-KFNGH), Riyadh and King Faisal Specialist Hospital and Research Centre (KFHRC), Jeddah, Saudi Arabia. Data were gathered on 227 Saudi patients on chronic maintenance hemodialysis or chronic peritoneal dialysis. The prevalence of RLS was measured using IRLSSG's RLS Questionnaire (RLSQ). Potential risk factors for RLS including other sleep disorders, underlying cause of chronic renal failure, duration on dialysis, dialysis shift, biochemical tests and demographic data were also evaluated. The overall prevalence of RLS was 50.22% including 53.7% males and 46.3% females. Their mean age was 55.7 +/- 17.2 years and mean duration on dialysis 40.4 +/- 37.8 months. Significant predictors of RLS were history of diabetes mellitus (DM), coffee intake, afternoon dialysis, gender and type of dialysis (P= 0.03, 0.01, < 0.001, 0.05 and 0.009 respectively). Patients with RLS were found to be at increased risk of having insomnia and excessive daytime sleepiness (EDS) (P= < 0.001 and 0.001, respectively). Our study suggests that RLS is a very common problem in dialysis population and was significantly associated with other sleep disorders, particularly insomnia, and EDS. Optimal care of dialysis patient should include particular attention to the diagnosis and

  2. [Pain in venous thrombosis of the leg].

    Science.gov (United States)

    Henriet, J P

    1992-01-01

    According to D. Reinharez, pain and edema are the commonest presenting symptoms in phlebology. Pain is one of the most classical symptoms of an ordinary deep venous thrombosis, a valuable feature when present, in the form of deep tension, heaviness, swelling and a feeling of dead weight. It is often absent or slight. It may consist merely of a dull cramp, or of an "undefinable" (C. Bourde) odd, heavy leg. It generally affects the calf but may involve the sole of the foot, the heel, the thigh, the groin or even the true pelvis. This feeling, although "imprecise and variable" (P. Wallois, P. Griton) is highly suggestive. It increases on standing and walking in the form of unilateral uncomfortable tension, heaviness or painful swelling, which maybe a source of worry or even anxiety to the patient. Tenderness on palpation of venous tracts and their stretching is more suggestive. In the opinion of M. Duruble, Neuhof's sign (feeling of tender fullness of the calf) is more reliable than Homans' sign (pain in the calf caused by passive dorsiflexion of the foot, with the lower limb in extension) which essentially stretches only the posterior tibial venous system. The value of Sigg's sign (pain in the popliteal fossa on passive extension of the knee) is controversial. Far more rare is phlegmasia coerulea dolens or Grégoire's blue leg, complicating phlegmasia alba dolens or of sudden onset, with initial very severe or even "intolerable" pain (J.J. Pinot) in Scarpa's triangle, rapidly spreading to the limb. In varicose phlebitis (M. Perrin) or superficial thrombophlebitis or varico-phlebitis (A.A. Ramelet) or superficial venitis (J.P. Henriet), pain most often consists of moderate burning tension overlying the thrombosed vein(s), increased by palpation and mobilisation. Sometimes severe initially, it is exacerbated by the slightest touch. In total, pain, regardless of its characteristics, its site and/or its severity, is one of the most constant clinical features of venous

  3. Does cold acclimation induce nonshivering thermogenesis in juvenile birds? Experiments with Pekin ducklings and Japanese quail chicks.

    Science.gov (United States)

    Marjoniemi, K; Hohtola, E

    2000-11-01

    The capability to produce heat in cold by nonshivering thermogenesis (NST) was studied in Pekin ducklings and Japanese quail chicks acclimated to cold for 3 weeks using indirect calorimetry (oxygen consumption) and electromyography from breast (M. pectoralis) and leg muscles (quails: M. gastrocnemius; ducklings: M. gastrocnemius, M. iliofibularis). Respiration of muscles in vitro was studied by measuring cytochrome c oxidase activity. In both species, cold acclimation induced clear morphometric and physiological changes, but no clear evidence of nonshivering thermogenesis. This was evident because increased shivering at least in one muscle coincided with increased oxygen consumption. In ducklings, however, amplitudes of shivering EMGs were low (muscles studied in both the control and cold-acclimated groups. Ducklings reacted to cold mainly by means of increasing body weight (1796 g in control, 2095 g in cold-acclimated) and circulatory changes. Acclimation did not change oxygen consumption either in vivo or in vitro. In quails, in addition to increased body weight (78.1 g control, 89.9 g cold-acclimated), improved insulation and metabolic adaptation to cold (increased respiration in vivo and in M. pectoralis in vitro) was also utilized. In Japanese quail chicks, 3 weeks of cold acclimation does not seem to induce NST, while in Pekin ducklings the existence of NST could not be totally excluded because of weak overall shivering activity.

  4. The physiological role of fat body and muscle tissues in response to cold stress in the tropical cockroach Gromphadorhina coquereliana.

    Science.gov (United States)

    Chowański, Szymon; Lubawy, Jan; Paluch-Lubawa, Ewelina; Spochacz, Marta; Rosiński, Grzegorz; Słocińska, Małgorzata

    2017-01-01

    Protective mechanisms against cold stress are well studied in terrestrial and polar insects; however, little is known about these mechanisms in tropical insects. In our study, we tested if a tropical cockroach Gromphadorhina coquereliana, possesses any protective mechanisms against cold stress. Based on the results of earlier studies, we examined how short-term (3 h) cold (4°C) influences biochemical parameters, mitochondrial respiration activity, and the level of HSPs and aquaporins expression in the fat body and leg muscles of G. coquereliana. Following cold exposure, we found that the level of carbohydrates, lipids and proteins did not change significantly. Nevertheless, we observed significant changes in mitochondrial respiration activity. The oxygen consumption of resting (state 4) and phosphorylating (state 3) mitochondria was altered following cold exposure. The increase in respiratory rate in state 4 respiration was observed in both tissues. In state 3, oxygen consumption by mitochondria in fat body was significantly lower compared to control insects, whereas there were no changes observed for mitochondria in muscle tissue. Moreover, there were cold-induced changes in UCP protein activity, but the changes in activity differed in fat body and in muscles. Additionally, we detected changes in the level of HSP70 and aquaporins expression. Insects treated with cold had significantly higher levels of HSP70 in fat body and muscles. On the other hand, there were lower levels of aquaporins in both tissues following exposure to cold. These results suggest that fat body play an important role in protecting tropical insects from cold stress.

  5. Paroxysmal cold hemoglobinuria.

    Science.gov (United States)

    Shanbhag, Satish; Spivak, Jerry

    2015-06-01

    Paroxysmal cold hemoglobinuria is a rare cause of autoimmune hemolytic anemia predominantly seen as an acute form in young children after viral illnesses and in a chronic form in some hematological malignancies and tertiary syphilis. It is a complement mediated intravascular hemolytic anemia associated with a biphasic antibody against the P antigen on red cells. The antibody attaches to red cells at colder temperatures and causes red cell lysis when blood recirculates to warmer parts of the body. Treatment is mainly supportive and with red cell transfusion, but immunosuppressive therapy may be effective in severe cases.

  6. Exception in Cold War

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ In the Cold War, India mainly focused its Southeast Asia Strategy on preserving the regional peace and stability, fearing that changes in Southeast Asia would impact India. Generally speaking, India would like to see a relatively strong, stable and independent Southeast Asia, which would guarantee the stability of its east wing. However, fettered by its limited power, its non-alignment policy and its special relation with Soviet Union, India's policy toward Southeast Asia remained relatively passive and its relation with Southeast Asia was, to some extent, trapped in a historical "intermission."

  7. Optimal Airline Multi-Leg Flight Seat Inventory Control

    Science.gov (United States)

    Nechval, Nicholas A.; Rozite, Kristine; Strelchonok, Vladimir F.

    2006-06-01

    In this paper, the problem of determining optimal booking policy for multiple fare classes in a pool of identical seats for multi-leg flights is considered. For large commercial airlines, efficiently setting and updating seat allocation targets for each passenger category on each multi-leg flight is an extremely difficult problem. This paper presents static and dynamic policies of allocation of airline seats for multi-leg flights with multiple fare classes, which allow one to maximize an expected contribution to profit. The dynamic policy uses the most recent demand and capacity information and allows one to allocate seats dynamically with anticipation over time. A numerical example is given.

  8. Evaluation of leg varicose veins by MR venography

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Yoshifumi; Shiraishi, Tomokuni; Taira, Mitsuru [Kansai Medical Univ., Neyagawa, Osaka (Japan). Kohri Hospital; Imamura, Atsushi; Yamada, Hitoshi; Okuno, Masafumi; Kamiyama, Yasuo

    1998-11-01

    Preoperative evaluation was conducted on 30 patients with leg varicose veins by MR venography (MRV), and compared with conventional venography, MR images were performed by the 3D-SMASH Method. Compared with venography, MRV could more clearly demonstrate leg varicose veins with perforating veins than venography. It could detected fine varicose veins more than 2 mm in diameter, and deep veins. Furthermore, 3D observation enables accurate detection of the location of perforating vein. In conclusion, MRV is useful for the diagnosis of leg varicose vein. (author)

  9. Restless Leg Syndrome in Neurologic and Medical Disorders.

    Science.gov (United States)

    Askenasy, Nadir; Askenasy, Jean-Jacques

    2015-09-01

    Adopting prior models of sleep-wake transitions, a flip-flop switch in synchronized neurotransmitter activity is proposed to underlie restless leg syndrome onset. In this model, leg quiescence homeostasis sustained through concerted activities of several neurotransmitters in basal ganglia is perturbed and produces striatal motor activity along sensory activity associated with thalamocortical circuits (conscious urge and discomfort). This model explains the association of restless leg syndrome with a wide variety of associated pathologies emphasizing that perturbed function and imbalance may occur under different steady states of neurotransmitter levels. Likewise, this concept links various central and peripheral etiologies and integrates the augmenting and transient effects of therapeutic neuromodulators.

  10. Thermocouple Boundary Layer Rake

    Science.gov (United States)

    Hwang, Danny P. (Inventor); Will, Herbert A. (Inventor); Fralick, Gustave C. (Inventor)

    2002-01-01

    Apparatus and method for providing a velocity flow profile near a reference surface. A measuring device utilizes a plurality of thermojunction pairs to provide the velocity flow profile in accordance with behavior of a gas relative to a constant thickness strut which stands vertically from the reference surface such that the span is normal to the surface, and the chord is parallel to the surface along the initial flow direction. Each thermojunction is carried on either side of a heater formed on a measuring surface in a constant thickness portion of a strut. Additionally, each thermojunction of a given pair is located at a predetermined height from the reference surface. Gas velocity data obtained from temperature differentials from one side of the heater to the other at each successive height is utilized to generate the velocity and turbulence level profiles.

  11. THERMOCOUPLE VACUUM GAUGE

    Science.gov (United States)

    Price, G.W.

    1954-08-01

    A protector device is described for use in controlling the pressure within a cyclotron. In particular, an electrical circuit functions to actuate a vacuum pump when a predetermined low pressure is reached and disconnect the pump when the pressure increases abcve a certain value. The principal feature of the control circuit lies in the use of a voltage divider network at the input to a relay control tube comprising two parallel, adjustable resistances wherein one resistor is switched into the circuit when the relay connects the pump to a power source. With this arrangement the relay is energized at one input level received from a sensing element within the cyclotron chamber and is de-energized when a second input level, representing the higher pressure limit, is reached.

  12. One-wire thermocouple

    Science.gov (United States)

    Goodrich, W. D.; Staimach, C. J.

    1977-01-01

    Nickel alloy/constantan device accurately measures surface temperature at precise locations. Device is moderate in cost and simplifies fabrication of highly-instrumented seamless-surface heat-transfer models. Device also applies to metal surfaces if constantan wire has insulative coat.

  13. Primary headaches in restless legs syndrome patients

    Directory of Open Access Journals (Sweden)

    Ravi Gupta

    2012-01-01

    Full Text Available Earlier studies conducted among migraineurs have shown an association between migraine and restless legs syndrome (RLS. We chose RLS patients and looked for migraine to exclude sample bias. Materials and Methods: 99 consecutive subjects of idiopathic RLS were recruited from the sleep clinic during four months period. Physician diagnosis of headache and depressive disorder was made with the help of ICHD-2 and DSM-IV-TR criteria, respectively. Sleep history was gathered. Severity of RLS and insomnia was measured using IRLS (Hindi version and insomnia severity index Hindi version, respectively. Chi-square test, one way ANOVA and t-test were applied to find out the significance. Results: Primary headache was seen in 51.5% cases of RLS. Migraine was reported by 44.4% subjects and other types of ′primary headaches′ were reported by 7.1% subjects. Subjects were divided into- RLS; RLS with migraine and RLS with other headache. Females outnumbered in migraine subgroup (χ2 =16.46, P<0.001. Prevalence of depression (χ2 =3.12, P=0.21 and family history of RLS (χ2 =2.65, P=0.26 were not different among groups. Severity of RLS (P=0.22 or insomnia (P=0.43 were also similar. Conclusion: Migraine is frequently found in RLS patients in clinic based samples. Females with RLS are prone to develop migraine. Depression and severity of RLS or insomnia do not affect development of headache.

  14. Clinical correlates of the restless legs syndrome

    Directory of Open Access Journals (Sweden)

    Luis Fabiano Marin

    2012-07-01

    Full Text Available OBJECTIVE: To determine the clinical correlates of the restless legs syndrome (RLS in a Brazilian sleep disorders center. METHODS: We retrospectively studied 118 patients with RLS from January, 2004, to December, 2010. The analyzed variables were: age at disease onset, gender, race, years of school instruction, primary and secondary RLS, and treatment options. RESULTS: Among the studied patients, 83.9% were women with a female/male sex ratio of 5:1. Mean age of the patients at symptom onset ± standard deviation was 41.7±17.9 years-old. The primary RLS was found in 85% of patients. The other 15% remainders consisted of secondary forms, and they were associated with neuropathy, iron deficiency anemia, end-stage renal disease, or Parkinson's disease. Drug therapy for RLS was introduced in 67% of patients. CONCLUSIONS: Most patients presented primary RLS with an early disease onset. Further epidemiological studies are welcomed to provide better information on secondary RLS in Brazil.

  15. Restless legs syndrome and pregnancy: A review

    Science.gov (United States)

    Srivanitchapoom, Prachaya; Pandey, Sanjay; Hallett, Mark

    2014-01-01

    Restless legs syndrome (RLS) is a common sensorimotor neurological disorder that is diagnosed according to the revised criteria of the International RLS Study Group (IRLSSG). The pathophysiology of RLS is still unknown and its prevalence is influenced by ethnicity, age, and gender. RLS is divided into two types by etiology: primary or idiopathic and secondary. Primary RLS is strongly influenced by a genetic component while secondary RLS is caused by other associated conditions such as end-stage renal disease or peripheral neuropathy. Another common condition associated with RLS is pregnancy. The prevalence of RLS during pregnancy is two to three times higher than in the normal population and is influenced by the trimester and the number of parity. The main mechanisms that may contribute to the pathophysiology of RLS during pregnancy are hormonal changes and iron and folate status. Standard medications for treating RLS during pregnancy are not established. Most medications have been used according to the evidence from non-pregnant patients. Therefore, consideration of the medical treatment for treating RLS during pregnancy should be balanced between the benefit of relieving the symptoms and maternal and fetal risk. In general, the prognosis of RLS during pregnancy is good and symptoms are usually relieved after delivery. PMID:24768121

  16. Restless legs syndrome associated with major diseases

    Science.gov (United States)

    Allen, Richard; Högl, Birgit; Paulus, Walter

    2016-01-01

    Recent publications on both the genetics and environmental factors of restless legs syndrome (RLS) defined as a clinical disorder suggest that overlapping genetic risk factors may play a role in primary (idiopathic) and secondary (symptomatic) RLS. Following a systematic literature search of RLS associated with comorbidities, we identified an increased prevalence of RLS only in iron deficiency and kidney disease. In cardiovascular disease, arterial hypertension, diabetes, migraine, and Parkinson disease, the methodology of studies was poor, but an association might be possible. There is insufficient evidence for conditions such as anemia (without iron deficiency), chronic obstructive pulmonary disease, multiple sclerosis, headache, stroke, narcolepsy, and ataxias. Based on possible gene–microenvironmental interaction, the classifications primary and secondary RLS may suggest an inappropriate causal relation. We recognize that in some conditions, treatment of the underlying disease should be achieved as far as possible to reduce or eliminate RLS symptoms. RLS might be seen as a continuous spectrum with a major genetic contribution at one end and a major environmental or comorbid disease contribution at the other. PMID:26944272

  17. [Innovative therapy for leg ulcers: Electrostimulation].

    Science.gov (United States)

    Maillard, H

    2015-01-01

    Chronic wounds can take a long time to heal despite appropriate therapy based upon aetiology and use of suitable dressings. The success of electrostimulation is based upon the existence within the skin of the endogenous currents involved in the wound healing process. Where skin continuity is broken by a wound, these electrical potentials are short-circuited, resulting in leakage of electrical current. Woundel(®) therapy is the only such treatment currently available in France and is based on the use of continuous pulsed current that generates an electrical field near the endogenous electrical fields. It utilises a console to deliver the electrical impulses, a dressing electrode and a dispersion electrode. The electrode dressing is left on the wound for 3 days, and venous compression bandaging may be applied to the leg, taking care to leave the connector free. Negative polarity stimulates migration of fibroblasts, resulting in elimination of fibrin. Positive polarity causes keratinocyte migration, which in turn leads to epidermisation. Electrostimulation is of recognised utility in the healing of chronic wounds: it has been assigned a high-level recommendation in the European and American guidelines for the treatment of venous ulcers and bedsores with proof level of A. Further, the analgesic effect of electrostimulation has been demonstrated in several studies. Electrostimulation is already well developed in France among wound specialists, but prospective studies are planned so that it may be used at patients' homes.

  18. Athermal laser treatment of the diabetic leg

    Science.gov (United States)

    Ignat, P.; Suteanu, S.; Brojbeanu, Gabriela; Vasiliu, Virgil V.

    1995-03-01

    This work shows the result obtained in the medical clinic of the `Dr. I. Cantacuzino Hospital' on a lot of 43 diabetic patients using the `LASSIS' devices composed of a He-Ne laser and 4 semiconductor lasers. The 43 patients showed various clinic pictures of a diabetic leg (diabetic arteriopathy and neuropathy) 16 of the lot showed an arteriopathy with claudication and a decrease of pulses oscillometrically measurements, 15 had ulceration and a beginning of gangrene and the other 12 showed a plantary boring ill. There has been achieved an amelioration of the oscillometric index of the claudication while walking the amelioration of local circulation, together with the limitation of the necrosis. For the boring ill, there has been achieved the acceleration of the granulating and epithelization process avoiding surgeries, suppuration and cutaneous plasties. The response to the laser treatment was compared to the response to the classic treatment (vasodilatation surgery unstrapping, antibiotherapy) on a proving lot. We appreciated that the cicatrization and local vasodilatation with athermal laser treatment should be a hope for the treatment of patients suffering of diabetic arteriopathy and neuropathy.

  19. Restless legs syndrome and pregnancy: a review.

    Science.gov (United States)

    Srivanitchapoom, Prachaya; Pandey, Sanjay; Hallett, Mark

    2014-07-01

    Restless legs syndrome (RLS) is a common sensorimotor neurological disorder that is diagnosed according to the revised criteria of the International RLS Study Group (IRLSSG). The pathophysiology of RLS is still unknown and its prevalence is influenced by ethnicity, age, and gender. RLS is divided into two types by etiology: primary or idiopathic and secondary. Primary RLS is strongly influenced by a genetic component while secondary RLS is caused by other associated conditions such as end-stage renal disease or peripheral neuropathy. Another common condition associated with RLS is pregnancy. The prevalence of RLS during pregnancy is two to three times higher than in the normal population and is influenced by the trimester and the number of parity. The main mechanisms that may contribute to the pathophysiology of RLS during pregnancy are hormonal changes and iron and folate status. Standard medications for treating RLS during pregnancy are not established. Most medications have been used according to the evidence from non-pregnant patients. Therefore, consideration of the medical treatment for treating RLS during pregnancy should be balanced between the benefit of relieving the symptoms and maternal and fetal risk. In general, the prognosis of RLS during pregnancy is good and symptoms are usually relieved after delivery.

  20. Pramipexole alters thermoregulation in restless legs syndrome.

    Science.gov (United States)

    Salminen, Aaro V; Rimpilä, Ville; Polo, Olli

    2014-12-15

    Previous studies have associated restless legs syndrome (RLS) with peripheral hypoxia and impaired thermoregulation in the lower extremities. We performed long-term monitoring of skin temperatures in order to investigate whether these findings could be explained by reduced blood flow to the peripheral tissues. 96-hour continuous measurements of skin temperature were performed both in the distal and proximal parts of the body of 15 patients with RLS and 14 healthy controls. During the recording, the patients participated in suggested immobilization tests both with and without pramipexole medication. We found no baseline differences in distal or proximal skin temperature between patients and controls in daytime or during immobilization. However, pramipexole significantly increased distal skin temperature in the patient group during immobilization (31.1°C vs. 32.9°C, p thermoregulation and the previous studies might have been biased by medication. Dopaminergic medication is a major confounding factor when assessing peripheral phenomena in RLS and should be controlled for in the future studies. © 2014 American Academy of Sleep Medicine.

  1. Measurement of L-(1-/sup 14/C)leucine kinetics in splanchnic and leg tissues in humans. Effect of amino acid infusion

    Energy Technology Data Exchange (ETDEWEB)

    Gelfand, R.A.; Glickman, M.G.; Castellino, P.; Louard, R.J.; DeFronzo, R.A.

    1988-10-01

    Although whole-body leucine flux is widely measured to study body protein turnover in humans, the contribution of specific tissues to the total-body measurement remains unknown. By combining the organ-balance technique with the systemic infusion of L-(1-14C)leucine, we quantitated leucine production and disposal by splanchnic and leg tissues and by the whole body, simultaneously, in six normal men before and during amino acid infusion. At steady state, disposal of arterial leucine by splanchnic and leg tissues was calculated from the percent extraction (E) of L-(1-14C)leucine counts: uptake = E x (Leu)a x flow. Tissue release of cold leucine (from protein turnover) into vein was calculated as the difference between leucine uptake and the net tissue leucine balance. In the postabsorptive state, despite substantial (P less than .01) extraction of L-(1-14C)leucine by splanchnic (23 +/- 1%) and leg (18 +/- 2%) tissues, net leucine balance across both tissue beds was small, indicating active simultaneous disposal and production of leucine at nearly equivalent rates. Splanchnic tissues accounted for approximately 50% of the measured total-body leucine flux. During amino acid infusion, the net leucine balance across splanchnic and leg tissues became positive, reflecting not only an increase in leucine uptake but also a marked suppression (by approximately 50%, P less than .02) of cold leucine release. This reduction in splanchnic and leg leucine release was indicated by a sharp decline in whole-body endogenous leucine flux.

  2. Dissociation of periodic leg movements from arousals in restless legs syndrome.

    Science.gov (United States)

    Manconi, Mauro; Ferri, Raffaele; Zucconi, Marco; Bassetti, Claudio L; Fulda, Stephany; Aricò, Debora; Ferini-Strambi, Luigi

    2012-06-01

    The purpose of this study was to characterize the nature of the relation between periodic leg movements during sleep (PLMS) and cortical arousals to contribute to the debate on the clinical significance and treatment of PLMS. A prospective, placebo-controlled, single-blind, parallel group study was carried out including 46 drug-naive patients with idiopathic restless legs syndrome (RLS). Each patient underwent 2 consecutive full-night polysomnographic studies. The first night was the baseline night. Prior to the second night, 1 group received a single oral dose of 0.25mg pramipexole, whereas a second group received a single oral dose of 0.5mg clonazepam, and the remaining patients received placebo. Sleep stages, cyclic alternating pattern (CAP), and leg movement activity were scored following standard criteria; symptoms of RLS were also assessed. Pramipexole suppressed PLMS without affecting electroencephalographic (EEG) instability (CAP) and arousals (corresponding to CAP A3 and, partially, A2 subtypes), whereas clonazepam did the opposite, reducing non-rapid eye movement sleep EEG instability without effects on PLMS. Both drugs were effective on sensory RLS symptoms. This study demonstrates that a selective pharmacological approach can disconnect PLMS from arousal events, suggesting an indirect relation between each other. These results might weaken the hypothesis of a direct pathological role of PLMS in sleep disruption and can be important for the discussion on the existence of a distinct entity called periodic limb movements disorder. Moreover, the study opens the doors to the possibility of a joint treatment for RLS targeting sensory and motor symptoms, as well as sleep instability. Copyright © 2012 American Neurological Association.

  3. Restless Leg Syndrome Across the Globe: Epidemiology of the Restless Legs Syndrome/Willis-Ekbom Disease.

    Science.gov (United States)

    Koo, Brian B

    2015-09-01

    There are more than 50 epidemiologic studies measuring the prevalence of restless legs syndrome/Willis-Ekbom disease (RLS/WED) across 5 of the 6 inhabited continents (not Australia), most conducted in North America and Europe. Sufficient studies have been conducted in Asia, North America, and Europe to make inferences on RLS/WED prevalence by region. RLS/WED prevalence is thought to be highest in North America and Europe and lower in Asia. These differences across regions may be explained by cultural, environmental, and genetic factors. Future investigation is needed to determine to what extent these factors affect expression of RLS/WED according to world region.

  4. Restless legs syndrome, periodic leg movements, and periodic limb movement disorder in children.

    Science.gov (United States)

    Durmer, Jeffrey S; Quraishi, Ghazala H

    2011-06-01

    The characteristic symptoms of restless legs syndrome (RLS) have been known for hundreds of years and were first reported in medicine in the 1600s. Clinicians must consider potential mimics, comorbid, and associated conditions when evaluating children with RLS symptoms. The traditional differentiation of RLS from periodic limb movement disorder (PLMD) is noted in children as well as adults. Because current pediatric RLS research is sparse, this article provides the most up-to-date evidence-based as well as consensus opinion-based information on the subject of childhood RLS and PLMD. Prevalence, pathophysiology, diagnosis, treatment, and clinical associations are discussed. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Coldness triggers northward flight in remigrant monarch butterflies.

    Science.gov (United States)

    Guerra, Patrick A; Reppert, Steven M

    2013-03-01

    Each fall, eastern North American monarch butterflies (Danaus plexippus) migrate from their northern range to their overwintering grounds in central Mexico. Fall migrants are in reproductive diapause, and they use a time-compensated sun compass to navigate during the long journey south. Eye-sensed directional cues from the daylight sky (e.g., the horizontal or azimuthal position of the sun) are integrated in the sun compass in the midbrain central complex region. Sun compass output is time compensated by circadian clocks in the antennae so that fall migrants can maintain a fixed flight direction south. In the spring, the same migrants remigrate northward to the southern United States to initiate the northern leg of the migration cycle. Here we show that spring remigrants also use an antenna-dependent time-compensated sun compass to direct their northward flight. Remarkably, fall migrants prematurely exposed to overwintering-like coldness reverse their flight orientation to the north. The temperature microenvironment at the overwintering site is essential for successful completion of the migration cycle, because without cold exposure, aged migrants continue to orient south. Our discovery that coldness triggers the northward flight direction in spring remigrants solves one of the long-standing mysteries of the monarch migration.

  6. Emphysematous Pyelonephritis Presenting as Necrotizing Fasciitis of the Leg

    Directory of Open Access Journals (Sweden)

    Yu-Xiong Ye

    2009-03-01

    Full Text Available We report a 50-year-old man with poorly controlled diabetes mellitus who presented with a painful, swollen right leg. He had also experienced right flank pain for 1 week prior to admission. Physical examination was notable for tenderness over the right flank. The right leg was diffusely swollen and exquisitely tender to touch, with palpable crepitance. Laboratory tests revealed leukocytosis and pyuria. Computed tomography showed a right ureteral stone with hydronephrosis and characteristic findings of emphysematous pyelonephritis. Furthermore, a right perirenal gas-forming abscess with extension to the right leg was noted. The patient was successfully treated with antibiotic therapy, aggressive control of blood sugar, percutaneous drainage of the hydronephrosis and perirenal abscess, and aggressive debridement of the leg.

  7. Hereditary Lymphedema of the Leg – A Case Report

    Directory of Open Access Journals (Sweden)

    Birgit Heinig

    2017-07-01

    Full Text Available Primary of hereditary lymphedema is a rare but progressive disease. It is yet not curable. We present a 48-year-old male patient with hereditary lymphedema of his left leg, that was realised by minor trauma (able twist when he was seven years old. He had never been treated for lymphedema but experienced multiple erysipelas during his life. After diagnostic procedures to exclude other causes of leg swelling, the diagnosis of hereditary lymphedema of the leg, stage III was confirmed. We initialized complex decongestive therapy. During two weeks of intensive treatment, the circumference of the left leg could be reduced by 10 cm. This case illustrates the "natural course" hereditary lymphedema. But it raises the hope that even after decades of ignorance, the patients benefits from complex decongestive treatment. Therapeutic nihilism is unnecessary and poses lymphedema patients to risks of infection and secondary malignancies like Stewart-Trewes syndrome.

  8. Eyelash Transplantation Using Leg Hair by Follicular Unit Extraction

    Directory of Open Access Journals (Sweden)

    Sanusi Umar, MD

    2015-03-01

    Full Text Available Summary: Fine hairs of the head and nape areas have been used as donor sources in eyelash transplantation but are straight, coarse, and grow rapidly, requiring frequent eyelash maintenance. This is the first reported case of eyelash transplantation by follicular unit extraction using leg hair as a donor source; findings were compared with that of another patient who underwent a similar procedure with donor hairs from the nape area. Although both patients reported marked improvement in fullness of eyelashes within 3 months postsurgery, the transplanted leg hair eyelashes required less frequent trimming (every 5–6 weeks compared with nape hair eyelashes (every 2–3 weeks. Additionally, in leg hair eyelashes, the need for perming to sustain a natural looking eyelash curl was eliminated. Eyelash transplantation using leg donor hair in hirsute women may result in good cosmetic outcomes and require less maintenance compared with nape donor hair.

  9. Living with clipped wings - patients’ experience of losing a leg

    DEFF Research Database (Denmark)

    Norlyk, Annelise; Martinsen, Bente; Kjaer-Petersen, Klaus

    2013-01-01

    This study explores the lived experience of losing a leg as described by the patients themselves post-discharge. Studies have documented that regardless of aetiology patients are faced with severe physical as well as psychosocial challenges post-amputation. However, only few studies explore in....... The essential meaning of losing a leg is a radical and existential upheaval, which restricts patients' lifestyle and irretrievably alters their lifeworld. Life after the operation is associated with despair, and a painful sense of loss, but also with the hope of regaining personal independence. The consequences...... of losing a leg gradually materialize as the patients realize how the loss of mobility limits their freedom. Patients experience the professional help as primarily directed towards physical care and rehabilitation. The findings show that the loss of a leg and, subsequently, the restricted mobility carry...

  10. Drug No Better Than Placebo for Lower Back, Leg Pain

    Science.gov (United States)

    ... news/fullstory_164223.html Drug No Better Than Placebo for Lower Back, Leg Pain Pregabalin, commonly known ... name: Lyrica) may be no better than a placebo when it comes to treating the back and ...

  11. California Red-Legged Frogs in coastal dune drainages (2015)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — California Red-legged Frogs (Rana draytonii) are typically regarded as inhabitants of permanent ponds, marshes, and slow-moving streams, but their ecology in other...

  12. Using Malaria Medication for Leg Cramps Is Risky

    Science.gov (United States)

    ... Products Vaccines, Blood & Biologics Articulos en Espanol Using Malaria Medication for Leg Cramps is Risky Printer-friendly ... approved only to treat a certain type of malaria (uncomplicated malaria) caused by the parasite Plasmodium falciparum. ...

  13. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003775.htm Doppler ultrasound exam of an arm or leg To use ... this page, please enable JavaScript. This test uses ultrasound to look at the blood flow in the ...

  14. Leg ulcers in sickle cell patients: management challenges

    Directory of Open Access Journals (Sweden)

    El Khatib AM

    2016-11-01

    Full Text Available Arij M El Khatib,1 Shady N Hayek2 1Division of Plastic and Reconstructive Surgery, Department of Surgery, American University of Beirut Medical Center (AUBMC, 2Private Practice, Cosmetic Surgery Center, Beirut, Lebanon Abstract: Sickle cell disease is an autosomal recessive hemoglobinopathy caused by an amino acid substitution from glutamic acid to valine in the beta hemoglobin chain. One of the common symptoms occurring in sickle cell patients are leg ulcers, which are notoriously painful, difficult to treat, and frequently recurrent. These ulcers pose a therapeutic challenge with multiple modalities proposed for treatment, but with scarce evidence of efficacy of any single modality. Ulcer prevention, rigorous wound care, pain control, and surgery are the current mainstays of sickle cell leg ulcer treatment. Keywords: sickle cell leg ulcer, leg wound, sickle cell disease 

  15. Quality of Life in People with Leg Ulcer, Integrative Review

    Directory of Open Access Journals (Sweden)

    Daniela Alves

    2016-04-01

    Full Text Available Objective: To identify the main changes in the daily life of people with leg ulcer and how that affects the person’s quality of life. Methodology: We used the methodology PI [C] OD and selected four research articles, taken from EBSCO, PubMed, and EWMA. Results: The main changes identified in the people’s daily live with leg ulcers are physical (pain, decreased mobility, presence of exudate, bad smell from the wound and change in the style of clothing, psychological (sleep disorders, depression, anxiety, feelings of rejection and low self-steem, social (isolation, restriction in leisure activities, inability to perform household chores. Conclusions: The literature about the person’s quality of life with leg ulcer reported a significant impact in the daily life. The care provided by nurses should be centered on the person, integrating all the kind of needs and the leg ulcer must not be the sole focus of care

  16. Vibration transmission characteristics of the legs of freely standing honeybees

    DEFF Research Database (Denmark)

    Rohrseitz, Kristin; Kilpinen, Ole

    1997-01-01

    The leg vibrations of honeybees standing on a vibrating substrate were measured with laser Doppler vibrometry, both in freely standing bees and in bees attached to a holder. In both cases, no resonances were found. In the fixed bee preparation, the legs moved with approximately the same amplitude...... as the stimulator. This was also the case in freely standing honeybees, except around 400 Hz, where an average attenuation of approximately 6 dB was observed. In the fixed bee preparation, the vertical movements of the legs were also measured during horizontal stimulation. The vertical vibration amplitude...... of the legs was 15-20 dB lower than the horizontal stimulation amplitude. The electrophysiologically and behaviourally determined thresholds for vibration stimulation increased by approximately 10 dB, when the stimulus direction was changed from vertical to horizontal. These observations support the notion...

  17. Restless legs syndrome: demographics, presentation, and differential diagnosis.

    Science.gov (United States)

    Hening, Wayne; Allen, Richard P; Tenzer, Penny; Winkelman, John W

    2007-09-01

    Restless legs syndrome (RLS) is a sensorimotor disorder characterized by a distressing urge to move the legs and sometimes other parts of the body. Diagnosis is based on clinical features that may be easily remembered with the mnemonic URGE: Urge to move, Rest induced, Gets better with activity, and Evening and night accentuation. RLS is common, its prevalence increases with age, and women are more frequently affected. The course is chronic with often severe sleep disruption, including periodic leg movements. Differential diagnosis includes disorders of restlessness and leg discomfort. Primary RLS is familial and likely to be genetic. Important causes of secondary RLS are end-stage renal disease, pregnancy, and iron deficiency. Every patient should be checked for iron status with a serum ferritin measurement.

  18. 铠装贵金属热电偶测量端位置的确定方法%Method for Determining Sheathed Noble Metal Thermocouple Measuring End Position

    Institute of Scientific and Technical Information of China (English)

    侯运安; 赵雪茹; 王兵利; 苏剑

    2015-01-01

    Accurate positioning of measuring ends of thermocouples has an important influence on the calibration and use of thermocouples, especially for armored noble metal thermocouples. It is impossible to accurately identify the position of thermocouple measuring ends inside protec-tion tubes by visual inspection, and therefore the top of protection tubes is chosen as the position for measuring ends in the calibration and use processes of thermocouples. However, through field test, the measuring ends of armored noble metal thermocouples are not located at the top of protection tubes. This paper provides a method for accurate positioning of armored noble metal thermocouple measuring ends.%热电偶测量端位置的准确定位对于热电偶的校准和使用有着重要影响,特别对于铠装贵金属热电偶来说,由于无法通过肉眼准确识别保护管内部热电偶测量端的位置,因此在热电偶检定和使用过程中一般将其外保护管顶部作为测量端所在位置。然而通过现场试验发现,铠装贵金属热电偶测量端一般并不位于保护管顶部,本文提供了一种准确定位铠装贵金属热电偶测量端的方法。

  19. Leg-adjustment strategies for stable running in three dimensions.

    Science.gov (United States)

    Peuker, Frank; Maufroy, Christophe; Seyfarth, André

    2012-09-01

    The dynamics of the center of mass (CoM) in the sagittal plane in humans and animals during running is well described by the spring-loaded inverted pendulum (SLIP). With appropriate parameters, SLIP running patterns are stable, and these models can recover from perturbations without the need for corrective strategies, such as the application of additional forces. Rather, it is sufficient to adjust the leg to a fixed angle relative to the ground. In this work, we consider the extension of the SLIP to three dimensions (3D SLIP) and investigate feed-forward strategies for leg adjustment during the flight phase. As in the SLIP model, the leg is placed at a fixed angle. We extend the scope of possible reference axes from only fixed horizontal and vertical axes to include the CoM velocity vector as a movement-related reference, resulting in six leg-adjustment strategies. Only leg-adjustment strategies that include the CoM velocity vector produced stable running and large parameter domains of stability. The ability of the model to recover from perturbations along the direction of motion (directional stability) depended on the strategy for lateral leg adjustment. Specifically, asymptotic and neutral directional stability was observed for strategies based on the global reference axis and the velocity vector, respectively. Additional features of velocity-based leg adjustment are running at arbitrary low speed (kinetic energy) and the emergence of large domains of stable 3D running that are smoothly transferred to 2D SLIP stability and even to 1D SLIP hopping. One of the additional leg-adjustment strategies represented a large convex region of parameters where stable and robust hopping and running patterns exist. Therefore, this strategy is a promising candidate for implementation into engineering applications, such as robots, for instance. In a preliminary comparison, the model predictions were in good agreement with the experimental data, suggesting that the 3D SLIP is an

  20. Design and Realization of Component Software For Thermocouple Calibration%组件式热电偶检定软件的设计与实现

    Institute of Scientific and Technical Information of China (English)

    刘慧英; 江豪; 李斌; 张丽红

    2011-01-01

    According to the fact that traditional programming ideas is generally used in the thermocouple calibration software, the modification and upgrade make quantities of troubles. A calibration software solution is presented based on component design idea and a set of new modularized thermocouple calibration software is designed. Using the measurement and control tool of Labwindows/CVI and the support to DLL( dynamic link library), it realized the development of calibration software. The testing result shows that it can accomplish the calibration of thermocouple automatically. The component design and developing ideas bring about a big convenience on programming, modifying and upgrading software.%针对目前热电偶检定软件皆采用传统编程思想,修改和升级比较麻烦的问题,提出了一种基于组件式设计思路的检定软件方案,设计了一套新型的模块化热电偶检定软件.利用LabWindows/CVI丰富的测控工具及对动态链接库的支持,实现了检定软件的开发.经现场测试,检定软件可自动完成热电偶的检定工作;组件式的设计及开发思路给软件的编制、修改和升级带来了很大的方便.