WorldWideScience

Sample records for coil aneurysm healing

  1. Local Delivery Is Critical for Monocyte Chemotactic Protein-1 Mediated Site-Specific Murine Aneurysm Healing.

    Science.gov (United States)

    Hourani, Siham; Motwani, Kartik; Wajima, Daisuke; Fazal, Hanain; Jones, Chad H; Doré, Sylvain; Hosaka, Koji; Hoh, Brian L

    2018-01-01

    Local delivery of monocyte chemotactic protein-1 (MCP-1/CCL2) via our drug-eluting coil has been shown to promote intrasaccular aneurysm healing via an inflammatory pathway. In this study, we validate the importance of local MCP-1 in murine aneurysm healing. Whether systemic, rather than local, delivery of MCP-1 can direct site-specific aneurysm healing has significant translational implications. If systemic MCP-1 is effective, then MCP-1 could be administered as a pill rather than by endovascular procedure. Furthermore, we confirm that MCP-1 is the primary effector in our MCP-1 eluting coil-mediated murine aneurysm healing model. We compare aneurysm healing with repeated intraperitoneal MCP-1 versus vehicle injection, in animals with control poly(lactic-co-glycolic) acid (PLGA)-coated coils. We demonstrate elimination of the MCP-1-associated tissue-healing response by knockout of MCP-1 or CCR2 (MCP-1 receptor) and by selectively inhibiting MCP-1 or CCR2. Using immunofluorescent probing, we explore the cell populations found in healed aneurysm tissue following each intervention. Systemically administered MCP-1 with PLGA coil control does not produce comparable aneurysm healing, as seen with MCP-1 eluting coils. MCP-1-directed aneurysm healing is eliminated by selective inhibition of MCP-1 or CCR2 and in MCP-1-deficient or CCR2-deficient mice. No difference was detected in M2 macrophage and myofibroblast/smooth muscle cell staining with systemic MCP-1 versus vehicle in aneurysm wall, but a significant increase in these cell types was observed with MCP-1 eluting coil implant and attenuated by MCP-1/CCR2 blockade or deficiency. We show that systemic MCP-1 concurrent with PLGA-coated platinum coil implant is not sufficient to produce site-specific aneurysm healing. MCP-1 is a critical, not merely complementary, actor in the aneurysm healing pathway.

  2. Comparison of shape memory polymer foam versus bare metal coil treatments in an in vivo porcine sidewall aneurysm model.

    Science.gov (United States)

    Horn, John; Hwang, Wonjun; Jessen, Staci L; Keller, Brandis K; Miller, Matthew W; Tuzun, Egemen; Hartman, Jonathan; Clubb, Fred J; Maitland, Duncan J

    2017-10-01

    The endovascular delivery of platinum alloy bare metal coils has been widely adapted to treat intracranial aneurysms. Despite the widespread clinical use of this technique, numerous suboptimal outcomes are possible. These may include chronic inflammation, low volume filling, coil compaction, and recanalization, all of which can lead to aneurysm recurrence, need for retreatment, and/or potential rupture. This study evaluates a treatment alternative in which polyurethane shape memory polymer (SMP) foam is used as an embolic aneurysm filler. The performance of this treatment method was compared to that of bare metal coils in a head-to-head in vivo study utilizing a porcine vein pouch aneurysm model. After 90 and 180 days post-treatment, gross and histological observations were used to assess aneurysm healing. At 90 days, the foam-treated aneurysms were at an advanced stage of healing compared to the coil-treated aneurysms and showed no signs of chronic inflammation. At 180 days, the foam-treated aneurysms exhibited an 89-93% reduction in cross-sectional area; whereas coiled aneurysms displayed an 18-34% area reduction. The superior healing in the foam-treated aneurysms at earlier stages suggests that SMP foam may be a viable alternative to current treatment methods. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1892-1905, 2017. © 2016 Wiley Periodicals, Inc.

  3. Cartilage and bone neoformation in rabbit carotid bifurcation aneurysms after endovascular coil embolization

    Directory of Open Access Journals (Sweden)

    H Plenk

    2008-11-01

    Full Text Available Occurrence and histomorphology of cartilage and bone neoformations was retrospectively evaluated in rabbit experimental aneurysms after endovascular coil embolization. During product development, 115 carotid bifurcation aneurysms were treated with hydrogel-containing devices (HydroCoil®, n=77; HydroSoft®, n=28; prototype Hydrogel-only, n=10; MicroVentionTerumo, Aliso Viejo, CA. Additional 29 aneurysms were treated with standard (n=22 or with degradable polymer-covered (n=7 platinum coils. After 4 to 52 weeks, the retrieved aneurysms were methylmethacrylate embedded, and ground sections were surface-stained with Rapid Bone Stain and Giemsa solution. Cartilage and/or bone tissue was assessed by light microscopy; respective tissue areas in the aneurysms were determined by computerized histomorphometry. Cartilage neoformation was observed from 26 to 52 weeks. Single chondrocytes to hyaline or fibrous cartilage areas, occupying up to 29% of the aneurysm cavity, were found in 6 aneurysms, treated with HydroCoil (n=4, Hydrogel-only (n=1, and resorbable polymer (n=1 devices. Chondral ossification associated cartilage neoformation in 2 of these 4 HydroCoil-treated aneurysms. Membranous woven and lamellar bone ossicles were observed from 13 to 52 weeks in 7 aneurysms, treated with HydroCoil (n=3 and platinum coil (n=4 devices. Altogether, cartilage and/or bone neoformation was observed in 13 (9% of 144 rabbit bifurcation aneurysms treated with various embolic devices. Incidence was low until 26 weeks, but increased at 52 weeks in both, HydroCoil and standard platinum coil treated aneurysms. As the neoformations were predominantly located in proximity to the aneurysm neck, they could be related to the long-term mechanobiology of cell differentiation during fibrovascular healing of blood flow-exposed embolized aneurysms.

  4. Cellular responses of bioabsorbable polymeric material and Guglielmi detachable coil in experimental aneurysms.

    Science.gov (United States)

    Murayama, Yuichi; Viñuela, Fernando; Tateshima, Satoshi; Gonzalez, Nestor R; Song, Joon K; Mahdavieh, Haleh; Iruela-Arispe, Luisa

    2002-04-01

    Acceleration of healing mechanisms is a promising approach to improve current limitations of endovascular aneurysm therapy with the use of platinum coils. We evaluated a new endovascular therapeutic, bioabsorbable polymeric material (BPM), which may promote cellular reaction in the aneurysms. Four different concentrations of lactide/glycolic acid copolymer [poly(D-L-lactic-co-glycolic acid)] (PLGA), 85/15, 75/25, 65/35, and 50/50, were used as BPMs. Sixteen experimental aneurysms were created in 8 swine. Eight-millimeter-long spiral-shaped BPMs were surgically implanted in the aneurysms without tight packing (n=3 for each BPM). Guglielmi detachable coils (GDCs) were used as control (n=4). The animals were killed 14 days after embolization, and angiographic, histological, and immunohistochemical analyses were performed. Despite loose packing of aneurysms with BPMs, faster BPMs such as 50/50 or 65/35 PLGA demonstrated more mature collagen formation and fibrosis in the sac and neck of the aneurysm. One aneurysm treated with 65/35 PLGA, 1 treated with 75/25 PLGA, and all 3 treated with 85/15 PLGA showed a neck remnant on angiography. There was a linear relationship between collagen levels and polymer degradation properties (r=-0.9513). This preliminary animal study indicates that acceleration of aneurysm healing with the use of BPM is feasible. This concept can be applied to decrease and perhaps prevent aneurysmal recanalization after endovascular treatment of cerebral aneurysms.

  5. Transcatheter Coil Embolization of Splenic Artery Aneurysm

    International Nuclear Information System (INIS)

    Yamamoto, Satoshi; Hirota, Shozo; Maeda, Hiroaki; Achiwa, Sachiko; Arai, Keisuke; Kobayashi, Kaoru; Nakao, Norio

    2008-01-01

    The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10). The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm

  6. Versatile fill coils: initial experience as framing coils for oblong aneurysms. A technical case report.

    Science.gov (United States)

    Osanai, Toshiya; Bain, Mark; Hui, Ferdinand K

    2014-01-01

    Coil embolization of oblong aneurysms is difficult because the majority of commercially available coils are manufactured with a helical or spherical tertiary structure. While adopting framing strategies for oblong aneurysms (aspect ratio ≥ 2: 1), traditional coils may be undersized in the long axis but oversized in the short axis, resulting in increased aneurysmal wall stress, risk of re-rupture, and difficulty creating a basket that respects the aneurysmal neck. We review three cases in which versatile filling coils (VFCs) were used as the initial coils for embolization of oblong aneurysms and report coil distribution characteristics and clinical outcomes. Packing density after VFC implantation was assessed using the software AngioSuite-Neuro edition and AngioCalc. a 58-year-old woman experienced a subarachnoid hemorrhage from a ruptured anterior communicating artery aneurysm (7.5 mm × 3.5 mm). A 3-6 mm × 15 cm VFC was selected as the first coil because the flexibility of its wave-loop structure facilitates framing of an irregularly shaped aneurysm. The loop portions of the structures tend to be pressed to the extremes of the aneurysmal sac by the wave component. The VFC was introduced smoothly into the aneurysmal sac without catheter kickback. We were then able to insert detachable filling coils without any adjunctive technique and achieved complete occlusion. Complete occlusion without severe complications was achieved in all three cases in our study. Average packing density after the first coil was 15.63%. VFC coils may have a specific role in framing oblong aneurysms given their complex loop-wave design, allowing spacing of the coils at the dome and neck while keeping sac stress to a minimum.

  7. HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms

    International Nuclear Information System (INIS)

    Fanning, Noel F.; Berentei, Zsolt; Brennan, Paul R.; Thornton, John

    2007-01-01

    Introduction The overall safety of the HydroCoil, an expansile hybrid hydrogel-platinum coil, is unknown. We report a prospective observational study of our first 100 cerebral aneurysms treated with HydroCoils, focusing on safety and initial efficacy.Methods Indications, procedural complications, clinical and angiographic outcomes were recorded. Packing density, number of coils deployed and angiographic results were compared with those in a matched control group of 100 aneurysms treated solely with bare platinum coils. HydroCoil complication rates were compared to bare platinum coil rates at our institution and in published series. Results Adjuvant HydroCoil treatment led to increased mean percentage aneurysm filling compared to controls (50 ± 21% versus 27 ± 13%, P < 0.001). Immediate posttreatment angiographic results showed significantly (P < 0.001) more complete occlusions and fewer incomplete (<95%) occlusions compared to controls. Intermediate follow-up angiograms (median 7.5 months) in 63 aneurysms showed a trend towards fewer incomplete occlusions with HydroCoil treatment. There were significantly fewer major recurrences with HydroCoil treatment compared to the control treatment (9.5% versus 22.6%, P 0.046). In the adjuvant HydroCoil group, major recurrent aneurysms had significantly less percentage volume packing with HydroCoils than non-recurrent aneurysms (50.3 ± 5.0% versus 65.3 ± 18.0%, P = 0.04). There was a 12% procedural complication rate, 6% procedural morbidity and 1% mortality rate, similar to institutional and reported bare platinum coil complication rates.Conclusion HydroCoils can be safely deployed with a similar complication rate to bare platinum coils. They result in improved aneurysm filling. Intermediate follow-up angiography showed significantly fewer major recurrences. Long-term follow-up is required to confirm initial improved stability. (orig.)

  8. Endothelial cell proliferation in swine experimental aneurysm after coil embolization.

    Directory of Open Access Journals (Sweden)

    Yumiko Mitome-Mishima

    Full Text Available After coil embolization, recanalization in cerebral aneurysms adversely influences long-term prognosis. Proliferation of endothelial cells on the coil surface may reduce the incidence of recanalization and further improve outcomes after coil embolization. We aimed to map the expression of proliferating tissue over the aneurysmal orifice and define the temporal profile of tissue growth in a swine experimental aneurysm model. We compared the outcomes after spontaneous thrombosis with those of coil embolization using histological and morphological techniques. In aneurysms that we not coiled, spontaneous thrombosis was observed, and weak, easily detachable proliferating tissue was evident in the aneurysmal neck. In contrast, in the coil embolization group, histological analysis showed endothelial-like cells lining the aneurysmal opening. Moreover, immunohistochemical and morphological analysis suggested that these cells were immature endothelial cells. Our results indicated the existence of endothelial cell proliferation 1 week after coil embolization and showed immature endothelial cells in septal tissue between the systemic circulation and the aneurysm. These findings suggest that endothelial cells are lead to and proliferate in the former aneurysmal orifice. This is the first examination to evaluate the temporal change of proliferating tissue in a swine experimental aneurysm model.

  9. Acceleration of aneurysm healing by P(DLLA-co-TMC)-coated coils enabling the controlled release of vascular endothelial growth factor

    International Nuclear Information System (INIS)

    Wang, Qiujing; Gao, Yuyuan; Sun, Xinlin; Ji, Bin; Cui, Xubo; Liu, Yaqi; Zheng, Tao; Chen, Chengwei; Jiang, Xiaodan; Zhu, Aiping; Quan, Daping

    2014-01-01

    Since the introduction of the detachable coil in endovascular treatment of intracranial aneurysms, the in-hospital mortality rate has been significantly decreased. Recurrence of the aneurysm remains the major drawback of using detachable coils. We prepared a bioactive coil coated with poly(d,l-lactide)-7co-(1,3-trimethylene carbonate) (P(DLLA-co-TMC)), a novel copolymer for controlling the release of vascular endothelial growth factor (VEGF). Platinum coils were prepared by successive coating with cationic P(DLLA-co-TMC) and anionic heparin. Then, recombinant human VEGF-165 (rhVEGF) was immobilized by affinity binding to heparin. The morphological characteristics and sustained in vitro release of rhVEGF were examined using scanning electron microscopy and enzyme-linked immunosorbent assay, respectively. The efficacy of these novel coils modified by P(DLLA-co-TMC)/rhVEGF was tested using a common carotid artery aneurysm model in rats. Experimental aneurysms were embolized with unmodified, P(DLLA-co-TMC)/heparin-coated or P(DLLA-co-TMC)/rhVEGF-coated platinum coils (n = 18). The coils were removed on days 15, 30 and 90 after insertion, and the histological and immunohistochemical analysis of factor VIII was performed to confirm the presence of endothelial cells in the organized area. In addition, the controlled in vivo release of VEGF was confirmed by Western blotting analysis. The release of VEGF tended to increase during the whole period and no burst release was observed. In the group treated with P(DLLA-co-TMC)/rhVEGF-coated platinum coils, clot organization and endothelial cell proliferation were accelerated. The immunohistochemistry study showed that the expression of factor VIII was found in the P(DLLA-co-TMC)/rhVEGF-coated coil group but not in the other two groups. Furthermore, Western blotting analysis confirmed that the major released VEGF in the aneurysm sac was from the P(DLLA-co-TMC)/VEGF-coated coil. P(DLLA-co-TMC)/rhVEGF-coated platinum coils can

  10. HydroSoft coil versus HydroCoil for endovascular aneurysm occlusion study: A single center experience

    International Nuclear Information System (INIS)

    Guo Xinbin; Fan Yimu; Zhang Jianning

    2011-01-01

    Background and purpose: The HydroCoil Embolic System (HES) was developed to reduce recurrences of aneurysms relative to platinum coils. But the HydroCoil Embolic System was characterized with many limitations. The manufacturer had recognized the challenge and recently a new design of hydrogel-coated coil-HydroSoft has become available in the market as the new generation HydroCoil. We reported our initial experience using HydroSoft coil versus HydroCoil in our center. Methods: 75 aneurysms embolized primarily using HydroSoft Coils from July 2008 to May 2009 were compared with 66 volume- and shape-matched aneurysms treated with HydroCoils from March 2006 to August 2008. Outcome measures included length and number of coils used, contrast volume, and length of hospital stay. During embolization, a stable framework was first established with bare coils, and hydrogel-coated coils were used subsequently to increase the packing density. Follow-up angiographic results 6 months after treatment were evaluated among some of the patients. Results: Successful coil embolization was achieved in all patients. There were no differences in average total coil length used per aneurysm. There were no differences in length of hospital stay and packing density. HydroSoft coils were more suitable using as the finishing or final coil. HydroSoft coil decreased the procedure-related retreated rates, and aneurysm packing was finished with soft, flexible HydroSoft coil and decreased the neck remnant rates. Follow-up angiography in HydroSoft-treated patients at 6 months revealed aneurysm stability without significant residual neck. Conclusions: HydroSoft coil allowed us to deploy coated coils with good packing density. A slight expansion of these coils at the neck can be expected to reduce neck remnant and potentially inhibit recurrence.

  11. A coil placement technique to treat intracranial aneurysm with incorporated artery.

    Science.gov (United States)

    Luo, Chao-Bao; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2018-03-01

    Endovascular coil embolization is an accepted treatment option for intracranial aneurysms. However, the coiling of aneurysms with an incorporated artery (IA) poses a high risk of IA occlusion. Here we report our experience of endovascular coil placement using a technique that avoids IA occlusion in aneurysms with IAs. Over a 6-year period, 185 patients harboring 206 intracranial aneurysms underwent endosaccular coiling. Forty-two of these patients with 45 aneurysms were treated by coil placement to avoid IAs occlusion. We assessed the anatomy of the aneurysms and IAs, technical feasibility of the procedure, and degree of aneurysm occlusion. Clinical and angiographic outcomes were assessed as well. Aneurysms were located in the supra-clinoid intracranial internal carotid artery (n = 24), anterior cerebral artery (n = 6), middle cerebral artery (n = 7), and vertebrobasilar artery (n = 8). The IA was at the aneurysm neck in 34 patients, body in 10, and dome in 1. Immediate post-coiling angiogram showed preservation of blood flow through the IA in all aneurysms. Coil compaction with aneurysmal regrowth was found in 7 of 36 patients having follow-up conventional angiography. One patient had an IA territory infarction after embolization. All 42 patients were followed up (mean: 21 months) and showed no re-bleeding. This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs. Copyright © 2017. Published by Elsevier Taiwan LLC.

  12. Surgical management of an ACM aneurysm eight years after coiling.

    Science.gov (United States)

    Pogády, P; Fellner, F; Trenkler, J; Wurm, G

    2007-04-01

    The authors present a case report on rebleeding of a medial cerebral aneurysm (MCA) eight years after complete endovascular coiling. The primarily successfully coiled MCA aneurysm showed a local regrowth which, however, was not the source of the rebleeding. The angiogram demonstrated no evidence of contrast filling of the coiled segment, but according to intraoperative findings (haematoma location, displacement of coils, evident place of rupture) there is no doubt that the coiled segment of the aneurysm was responsible for the haemorrhage.

  13. Comparison of the association of sac growth and coil compaction with recurrence in coil embolized cerebral aneurysms.

    Directory of Open Access Journals (Sweden)

    Anna L Hoppe

    Full Text Available In recurrent cerebral aneurysms treated by coil embolization, coil compaction is regarded as the presumptive mechanism. We test the hypothesis that aneurysm growth is the primary recurrence mechanism. We also test the hypothesis that the coil mass will translate a measurable extent when recurrence occurs.An objective, quantitative image analysis protocol was developed to determine the volumes of aneurysms and coil masses during initial and follow-up visits from 3D rotational angiograms. The population consisted of 15 recurrence and 12 non-recurrence control aneurysms initially completely coiled at a single center. An investigator sensitivity study was performed to assess the objectivity of the methods. Paired Wilcoxon tests (p<0.05, one-tailed were performed to assess for aneurysm and coil growth. The translation of the coil mass center at follow-up was computed. A Mann Whitney U-Test (p<0.05, one-tailed was used to compare translation of coil mass centers between recurrence and control subjects.Image analysis protocol was found to be insensitive to the investigator. Aneurysm growth was evident in the recurrence cohort (p=0.003 but not the control (p=0.136. There was no evidence of coil compaction in either the recurrence or control cohorts (recurrence: p=0.339; control: p=0.429. The translation of the coil mass centers was found to be significantly larger in the recurrence cohort than the control cohort (p=0.047.Aneurysm sac growth, not coil compaction, was the primary mechanism of recurrence following successful coil embolization. The coil mass likely translates to a measurable extent when recurrence occurs and has the potential to serve as a non-angiographic recurrence marker.

  14. Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysms

    International Nuclear Information System (INIS)

    Dinc, Hasan; Kuzeyli, Kayhan; Kosucu, Polat; Sari, Ahmet; Cekirge, Saruhan

    2006-01-01

    One of the feared complications during detachable coil embolization of cerebral aneurysms is herniation of a coil loop into the parent artery. Although coil protrusion of one or two loops into the parent vessel may not cause adverse events and in some instances can be ignored, the authors believe that coil retrieval is indicated if a free end is seen pulsating along the blood flow stream to prevent migration of the entire coil mass. In one patient, a microballoon was inflated across the neck of the aneurysm during retrieval of a herniated coil to prevent further coil herniation from the aneurysm sac. We present two cases in which prolapsed coils were successfully retrieved either using a microsnare and balloon combination or a microsnare alone. This report focuses on the efficacy of the Amplatz microsnare for such retrievals and the circumstances in which a herniated coil needs to be retrieved. We report two cases in which embolization coils partially migrated into the parent artery during endovascular treatment of cerebral aneurysm and were retrieved using the Amplatz Nitinol microsnare. (orig.)

  15. Effect of electromagnetic radiation on the coils used in aneurysm embolization.

    Science.gov (United States)

    Lv, Xianli; Wu, Zhongxue; Li, Youxiang

    2014-06-01

    This study evaluated the effects of electromagnetic radiation in our daily lives on the coils used in aneurysm embolization. Faraday's electromagnetic induction principle was applied to analyze the effects of electromagnetic radiation on the coils used in aneurysm embolization. To induce a current of 0.5mA in less than 5 mm platinum coils required to stimulate peripheral nerves, the minimum magnetic field will be 0.86 μT. To induce a current of 0.5 mA in platinum coils by a hair dryer, the minimum aneurysm radius is 2.5 mm (5 mm aneurysm). To induce a current of 0.5 mA in platinum coils by a computer or TV, the minimum aneurysm radius is 8.6 mm (approximate 17 mm aneurysm). The minimum magnetic field is much larger than the flux densities produced by computer and TV, while the minimum aneurysm radius is much larger than most aneurysm sizes to levels produced by computer and TV. At present, the effects of electromagnetic radiation in our daily lives on intracranial coils do not produce a harmful reaction. Patients with coiled aneurysm are advised to avoid using hair dryers. This theory needs to be proved by further detailed complex investigations. Doctors should give patients additional instructions before the procedure, depending on this study.

  16. Aneurysmal subarachnoid hemorrhage: outcome of aneurysm clipping versus coiling in anterior circulation aneurysm

    International Nuclear Information System (INIS)

    Wadd, I.H.; Haroon, A.; Ansari, S.

    2015-01-01

    To compare the neurological outcome of microsurgical clipping versus coiling in patients with anterior circulation aneurysm. Study Design: Comparative study. Place and Duration of Study: Department of Neurosurgery, Lahore General Hospital, Lahore, from January 2010 to December 2013. Methodology: Patients aged 14 - 60 years, with ruptured cerebral aneurysm of anterior circulation and World Federation of Neurosurgical Society (WFNS) grades 1, 2 and 3 were included. Patients more than 60 years, medically unfit patient and posterior circulation aneurysms and WFNS grades 4 and 5 were excluded. Aneurysm sac obliteration was done in randomized manner with microsurgical clipping or coiling. Postoperatively, the patients were assessed and followed-up upto one year for outcome parameters on the bases of WFNS grade and Modified Ranking Scale (mRS) as favourable (mRS =2 ) and unfavourable (mRS > 2). Results: Among 140 subjects selected for study, 70 were included in group A, i.e. coiling and other 70 were in group B, i.e. clipping. The median age of patients in group A was 52.5 ± 10 years and in group B was 51.00 ± years. Overall, 56 (40%) males, 28 (60%) males in each group; and 84 (60%) females, 42 (60%) in each group were included. The male to female ratio in this study was 1:1.5. In group A, i.e. coiling, 27 (38.6%) patients had no disability (grades 1 and 2), 25 (35.7%) were slightly disabled (grade 3) and 18 (25.7%) had moderate disability (grade 4); whereas in group B, i.e. clipping group 23 (32.9%) patients had no disability (grades 1 and 2), 23 (32.9%) were slightly disabled (grade 3) and 24 (34.3%) had moderate disability (grade 4). At one year follow-up, in group A, favourable outcome was achieved in 56 (80%) of patients compared to 48 (68.6%) in group B; whilst, 14 (20%) patients in group A and 22 (33.1%) in group B showed unfavourable outcome. Although mortality rate was higher in clipping (n=3, 4.3%) as compared to coiling (n=1, 1.4%), but was not statistically

  17. Coiling of ruptured pericallosal artery aneurysms.

    NARCIS (Netherlands)

    Menovsky, T.; Rooij, W.J.J. van; Sluzewski, M.; Wijnalda, D.

    2002-01-01

    OBJECTIVE: To assess the technical feasibility of treating ruptured pericallosal artery aneurysms with detachable coils and to evaluate the anatomic and clinical results. METHODS: Over a period of 27 months, 12 patients with a ruptured pericallosal artery aneurysm were treated with detachable

  18. The significant impact of framing coils on long-term outcomes in endovascular coiling for intracranial aneurysms: how to select an appropriate framing coil.

    Science.gov (United States)

    Ishida, Wataru; Sato, Masayuki; Amano, Tatsuo; Matsumaru, Yuji

    2016-09-01

    OBJECTIVE The importance of a framing coil (FC)-the first coil inserted into an aneurysm during endovascular coiling, also called a lead coil or a first coil-is recognized, but its impact on long-term outcomes, including recanalization and retreatment, is not well established. The purposes of this study were to test the hypothesis that the FC is a significant factor for aneurysmal recurrence and to provide some insights on appropriate FC selection. METHODS The authors retrospectively reviewed endovascular coiling for 280 unruptured intracranial aneurysms and gathered data on age, sex, aneurysm location, aneurysm morphology, maximal size, neck width, adjunctive techniques, recanalization, retreatment, follow-up periods, total volume packing density (VPD), volume packing density of the FC, and framing coil percentage (FCP; the percentage of FC volume in total coil volume) to clarify the associated factors for aneurysmal recurrence. RESULTS Of 236 aneurysms included in this study, 33 (14.0%) had recanalization, and 18 (7.6%) needed retreatment during a mean follow-up period of 37.7 ± 16.1 months. In multivariate analysis, aneurysm size (odds ratio [OR] = 1.29, p < 0.001), FCP < 32% (OR 3.54, p = 0.009), and VPD < 25% (OR 2.96, p = 0.015) were significantly associated with recanalization, while aneurysm size (OR 1.25, p < 0.001) and FCP < 32% (OR 6.91, p = 0.017) were significant predictors of retreatment. VPD as a continuous value or VPD with any cutoff value could not predict retreatment with statistical significance in multivariate analysis. CONCLUSIONS FCP, which is equal to the FC volume as a percentage of the total coil volume and is unaffected by the morphology of the aneurysm or the measurement error in aneurysm length, width, or height, is a novel predictor of recanalization and retreatment and is more significantly predictive of retreatment than VPD. To select FCs large enough to meet the condition of FCP ≥ 32% is a potential relevant factor for better

  19. Asymptomatic Delayed Coil Migration from an Intracranial Aneurysm: A Case Report

    Directory of Open Access Journals (Sweden)

    Anirban Deep Banerjee

    2011-01-01

    Full Text Available Objective. To describe asymptomatic delayed migration of a coil loop in a patient following successful coil embolization of an anterior communicating artery saccular aneurysm. Methods. A 24-year-old man with a ruptured anterior communicating artery saccular aneurysm underwent coil embolization with one helical ultrasoft coil. Results. A followup CT scan head and a cerebral angiogram one month following the procedure revealed distal migration of an intra-aneurysmal coil loop into the left pericallosal artery. The patient, however, remained asymptomatic. Conclusion. Delayed migration of coil following embolization of an intracranial aneurysm is an extremely rare occurrence. An asymptomatic presentation, as in our patient, is even more unique. The stent-like configuration of the migrated spiral coil loop probably prevented complete occlusion of the blood vessel.

  20. Stent-assisted coil embolization of intracranial aneurysms: a single center experience.

    Science.gov (United States)

    Luo, Chao-Bao; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo; Chang, Cheng-Yen

    2012-07-01

    Endovascular detachable coil embolization has become an important method in the management of intracranial aneurysms. However, coil embolization alone may fail to treat some wide-neck aneurysms. Herein, we report our experience with and outcome of stent-assisted coil embolization (SACE) of intracranial aneurysms. Over a 5-year period, a total of 59 patients diagnosed with 63 intracranial aneurysms underwent SACE. Of the total 63 aneurysms, 6 aneurysms were treated by SACE as a salvageable procedure because of coil instability after detachment. There were 17 men and 42 women enrolled in the study, with ages ranging from 24 to 86 years (mean: 60 years). We retrospectively assessed the clinical data, aneurysm characteristics, and angiographic and clinical outcomes of all patient cases. The mean aneurysm size was 9.4 mm, and the mean neck size was 5.5 mm. Clinical and angiographic follow-up exceeding 6 months were available in 51 and 40 patients, respectively. The mean clinical follow-up time was 28 months (range: 6-49 months). Successful stent deployment was found in 60 aneurysms (95%). Midterm total or subtotal angiographic aneurismal occlusion was obtained in 56 aneurysms (89%), with further thrombosis of the aneurismal sac occurring in 4 (10%). Stable coiling aneurysm was found in 24 (78%), aneurysm recurrence was observed in 5 (13%), and permanent procedural morbidity was observed in two patients (3.4%). During the follow-up period, there were no hemorrhagic events and no stent displacement. Despite a modest procedural complication rate, and some evidence of aneurismal recurrence, SACE was proved to be both effective and safe in managing wide-neck intracranial aneurysms. Our results also demonstrated the midterm durability and stability of aneurysm treated by SACE. Furthermore, SACE can be a salvageable procedure in cases with coil instability after detachment. Copyright © 2012. Published by Elsevier B.V.

  1. Impact of coil price knowledge by the operator on the cost of aneurysm coiling. A single center study.

    Science.gov (United States)

    Finitsis, Stephanos; Fahed, Robert; Gaulin, Ian; Roy, Daniel; Weill, Alain

    2017-09-15

    Endovascular treatment of aneurysms with coils is among the most frequent treatments in interventional neuroradiology, and represents an important expense. Each manufacturer has created several types of coils, with prices varying among brands and coil types. The objective of this study was to assess the impact of cost awareness of the exact price of each coil by the operating physician on the total cost of aneurysm coiling. This was a comparative study conducted over 1 year in a single tertiary care center. The reference cohort and the experimental cohort consisted of all aneurysm embolization procedures performed during the first 6 months and the last 6 months, respectively. During the second period, physicians were given an information sheet with the prices of all available coils and were requested to look at the sheet during each procedure with the instruction to try to reduce the total cost of the coils used. Expenses related to the coiling procedures during each period were compared. 77 aneurysms (39 ruptured) in the reference cohort and 73 aneurysms (36 ruptured) in the experimental cohort were treated, respectively. There was no statistically significant difference regarding aneurysm location and mean size. The overall cost of the coiling procedures, the mean number of coils used per procedure, and the median cost of each procedure did not differ significantly between the two cohorts. Awareness of the precise price of coils by operators without any additional measure did not have a scientifically proven impact on the cost of aneurysm embolization. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Comparison of devices used for stent-assisted coiling of intracranial aneurysms.

    Directory of Open Access Journals (Sweden)

    Benjamin Izar

    Full Text Available INTRODUCTION: Two self-expandable stents, the Neuroform and the Enterprise stent, are widely used for stent-assisted coiling (SAC of complex shaped intracranial aneurysms. However, comparative knowledge about technical feasibility, peri- and post-procedural morbidity and mortality, packing densities as well as follow-up data is limited. MATERIAL AND METHODS: We conducted a retrospective study to investigate differences in aneurysms stented with the Enterprise or Neuroform stents. Angiographic follow-up (mean 19.42 months was available in 72.6% (61/84 of aneurysms treated with stent-assisted coiling. We further sought to compare stent-assisted coiling to a matched patient population with aneurysms treated by conventional coil embolization. RESULTS: The stenting success rate of the Enterprise was higher compared to the Neuroform stent (46/48 and 42/51, respectively. In 5 of 9 cases in which the Neuroform stent was not navigable to the landing zone, we successfully deployed an Enterprise stent instead. Eventually, 42 aneurysms were coiled after stenting in each group. We observed no significant differences in peri-procedural complication rate, post-procedural hospital stay, packing density, recurrence rate or number of in-stent stenosis. Strikingly, 36.1% of followed aneurysms in the SAC group showed progressive occlusion on angiographic follow-up imaging. The packing density was significantly higher in aneurysms treated by SAC as compared to conventionally coiled aneurysms, while recanalization rate was significantly lower in the SAC group. CONCLUSION: The procedural success rate is higher using the Enterprise, but otherwise both stents exhibited similar characteristics. Lower recurrence frequency and complication rates comparable to conventional coil embolization emphasize the importance of stent-assisted coiling in the treatment of complex aneurysms. Progressive occlusion on angiographic follow-up was a distinct and frequent observation in the

  3. Endovascular coil embolization for anterior choroidal artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Moon; Chung, Eun Chul [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea); Kim, Dong Ik; Kim, Dong Joon; Suh, Sang Hyun [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Sun Yong [Ajou University College of Medicine, Department of Radiology, Suwon (Korea); Shin, Yong Sam [Ajou University College of Medicine, Department of Neurosurgery, Suwon (Korea); Park, Sung Il [Soonchunhyang University College of Medicine, Department of Radiology, Bucheon Hospital, Bucheon (Korea); Choi, Chun Sik; Won, Yu.Sam [Sungkyunkwan University School of Medicine, Department of Neurosurgery, Kangbuk Samsung Hospital, Seoul (Korea)

    2008-03-15

    We retrospectively evaluated the ischemic complications related to the anterior choroidal artery (AChA) and clinical outcome after coiling of AChA aneurysms. We included 37 patients (27 with subarachnoid hemorrhage, 10 without) harboring 38 AChA aneurysms (23 ruptured, 15 unruptured) who were treated by coiling at four institutions. Ischemic complications related to the AChA and clinical outcomes were retrospectively evaluated. Intraprocedural transient AChA occlusion occurred in five aneurysms, all of which had AChA incorporated into the aneurysm neck. Two of the five patients suffered postprocedural transient contralateral hemiparesis, but recovered completely. The remaining three patients had no postprocedural symptoms. Incidence of transient AChA occlusion was significantly higher in those aneurysms in which the AChA was incorporated into aneurysm neck (group 2) than in those in which the AChA was not incorporated (group 1). Of the 37 patients, 31 (83.8%) had good recoveries (modified Rankin scale score 0-2). Two patients died from the consequences of subarachnoid hemorrhage. During follow-up for a mean of 27 months (range 4-72 months), none of the 35 living patients re-bled. A total of 29 aneurysms in 28 patients were followed-up angiographically. Recurrences were found in 5 of the 29 aneurysms during follow-up (mean 18 months, range 6-45 months). Re-embolization achieved near complete occlusion of two recurrent aneurysms, both of which were still stable at the time of the next two follow-up angiographies. The other three recurrent aneurysms were not retreated due to the small size of the recurrences. Coiling of AChA aneurysms resulted in good outcomes without AChA-related permanent ischemic complications. Transient AChA occlusion, potentially associated with ischemic complications, was significantly more frequent in the aneurysm in which the AChA was incorporated into the aneurysm neck. (orig.)

  4. Endovascular treatment of intracranial aneurysms with bioactive Cerecyte coils: effects on treatment stability

    International Nuclear Information System (INIS)

    Geyik, Serdar; Yavuz, Kivilcim; Ergun, Onur; Koc, Osman; Cekirge, Saruhan; Saatci, Isil

    2008-01-01

    The Cerecyte coils were developed to improve long-term stability of embolized cerebral aneurysms by producing an increased fibrous reaction over the neck of the aneurysms. We report our preliminary clinical experience with mid-term follow-up. Seventy-eight consecutive patients with 84 intracranial aneurysms treated exclusively with Cerecyte coils were included in this study. Forty-eight aneurysms were ruptured and 36 were incidental. Twenty-two aneurysms were small with ( 25 mm). The embolization technique was the same with that in standard bare coiling. Immediate post-procedure angiography demonstrated complete aneurysm occlusion in 69%, neck remnant in 29.8% and incomplete occlusion in 1.2%. Follow-up angiography was obtained in 80 aneurysms in a period of time ranging from 6 months to 2 years. The overall recanalization rate was 11.3%, and the re-treatment rate was 6.3%; in the subgroup analysis, recanalization rates were 4.5% in S/S; 9.8% in S/W; and 33.3% in large aneurysms. The only giant aneurysm also showed recanalization. Procedure-related morbidity and mortality rates were 2.6% and 1.3%, respectively. Our midterm results showed a relatively low rate of recurrence compared to those reported for platinum coils with morbidity and mortality rates comparable to those with standard bare platinum coils. The efficacy of Cerecyte coils in the long term will be specifically addressed by the ongoing randomized Cerecyte coil trial. (orig.)

  5. Small Intracranial Aneurysm Treatment Using Target (®) Ultrasoft (™) Coils.

    Science.gov (United States)

    Jindal, Gaurav; Miller, Timothy; Iyohe, Moronke; Shivashankar, Ravi; Prasad, Vikram; Gandhi, Dheeraj

    2016-06-01

    The introduction of small, soft, complex-shaped microcoils has helped facilitate the endovascular treatment of small intracranial aneurysms (IAs) over the last several years. Here, we evaluate the initial safety and efficacy of treating small IAs using only Target(®) Ultrasoft(™) coils. A retrospective review of a prospectively maintained clinical database at a single, high volume, teaching hospital was performed from September 2011 to May 2015. IAs smaller than or equal to 5.0 mm in maximal dimension treated with only Target(®) Ultrasoft(™) coils were included. A total of 50 patients with 50 intracranial aneurysms were included. Subarachnoid hemorrhage from index aneurysm rupture was the indication for treatment in 23 of 50 (46%) cases, and prior subarachnoid hemorrhage (SAH) from another aneurysm was the indication for treatment in eight of 50 (16%) cases. The complete aneurysm occlusion rate was 70% (35/50), the minimal residual aneurysm rate was 14% (7/50), and residual aneurysm rate was 16% (8/50). One intraoperative aneurysm rupture occurred. Three patients died during hospitalization from clinical sequelae of subarachnoid hemorrhage. Follow-up at a mean of 13.6 months demonstrated complete aneurysm occlusion in 75% (30/40) of cases, near complete occlusion in 15% (6/40) of cases, and residual aneurysm in 10% (4/40) of cases, all four of which were retreated. Our initial results using only Target(®) Ultrasoft(™) coils for the endovascular treatment of small intracranial aneurysms demonstrate initial excellent safety and efficacy profiles.

  6. Endovascular treatment of intracranial aneurysms with bioactive Cerecyte coils: effects on treatment stability

    Energy Technology Data Exchange (ETDEWEB)

    Geyik, Serdar; Yavuz, Kivilcim; Ergun, Onur; Koc, Osman; Cekirge, Saruhan [Hacettepe University Hospitals, Department of Radiology, Ankara (Turkey); Saatci, Isil [Hacettepe University Hospitals, Department of Radiology, Ankara (Turkey); Hacettepe University Hospital, Interventional Neuroradiology Unit, Department of Radiology, Ankara (Turkey)

    2008-09-15

    The Cerecyte coils were developed to improve long-term stability of embolized cerebral aneurysms by producing an increased fibrous reaction over the neck of the aneurysms. We report our preliminary clinical experience with mid-term follow-up. Seventy-eight consecutive patients with 84 intracranial aneurysms treated exclusively with Cerecyte coils were included in this study. Forty-eight aneurysms were ruptured and 36 were incidental. Twenty-two aneurysms were small with (<10 mm) small neck (<4 mm) (SASN); 55 were small with wide neck ({>=}4 mm) (SAWN); six were large (10-25 mm) (L); and one was giant (G) (>25 mm). The embolization technique was the same with that in standard bare coiling. Immediate post-procedure angiography demonstrated complete aneurysm occlusion in 69%, neck remnant in 29.8% and incomplete occlusion in 1.2%. Follow-up angiography was obtained in 80 aneurysms in a period of time ranging from 6 months to 2 years. The overall recanalization rate was 11.3%, and the re-treatment rate was 6.3%; in the subgroup analysis, recanalization rates were 4.5% in S/S; 9.8% in S/W; and 33.3% in large aneurysms. The only giant aneurysm also showed recanalization. Procedure-related morbidity and mortality rates were 2.6% and 1.3%, respectively. Our midterm results showed a relatively low rate of recurrence compared to those reported for platinum coils with morbidity and mortality rates comparable to those with standard bare platinum coils. The efficacy of Cerecyte coils in the long term will be specifically addressed by the ongoing randomized Cerecyte coil trial. (orig.)

  7. Tiny intracranial aneurysms: Endovascular treatment by coil embolisation or sole stent deployment

    International Nuclear Information System (INIS)

    Lu Jun; Liu Jiachun; Wang Lijun; Qi Peng; Wang Daming

    2012-01-01

    Purpose: Tiny intracranial aneurysms pose a significant therapeutic challenge for interventional neuroradiologists. The authors report their preliminary results of endovascular treatment of these aneurysms. Methods: Between January 2002 and December 2009, 52 tiny intracranial aneurysms (defined as ≤3 mm in maximum diameter) in 46 patients (22 men; mean age, 57.9 years) were treated by endosaccular coil embolisation or sole stent deployment in the parent artery. Of 52 aneurysms, 29 had ruptured and 23 remained unruptured. The initial angiographic results, procedural complications, and clinical outcomes were assessed at discharge. Imaging follow-up was performed with cerebral angiography. Results: One aneurysm coiling procedure failed because of unsuccessful micro-catheterization. Forty-three aneurysms were successfully coil embolized, of which complete occlusion was obtained in 14, subtotal occlusion in 18 and incomplete occlusion in 11. The other 8 aneurysms were treated by sole stent deployment in the parent artery. Procedural complications (2 intraprocedural ruptures and 3 thromboembolic events) occurred in 5 (9.6%) of 52 aneurysms, resulting in permanent morbidity in only 1 (2.2%, 1/46) patient. No rebleeding occurred during clinical follow-up (mean duration, 46.7 months). Of the 16 coiled aneurysms that receiving repetitive angiography, 6 initially completely and 3 subtotally occluded aneurysms remained unchanged, 4 initially subtotally and 3 incompletely occluded aneurysms progressed to total occlusion. Five sole stent deployed aneurysms received angiographic follow-up (mean duration, 10.0 months), of which 3 remained unchanged, 1 became smaller and 1 progressed to total occlusion. Conclusion: Endovascular treatment of tiny intracranial aneurysms is technical feasible and relatively safe. Coil embolisation seems to be effective in preventing early recanalisation, whereas sole stenting technique needs further investigation to determine its effectiveness.

  8. Mesenteric ischaemia after endovascular coiling of ruptured cerebral aneurysms.

    LENUS (Irish Health Repository)

    Kamel, M H

    2012-02-03

    Three patients were referred to a national neurosurgical centre following CT evidence of subarachnoid haemorrhage. The three patients, who were referred from different institutions within a seven week period, were Fisher grade 3 and WFNS Grade I at all times. Angiography showed a PCOM aneurysm in one case, a ruptured Basilar tip aneurysm and an unruptured ACOM aneurysm in another case, and an ACOM aneurysm in the third case. It was decided that the aneurysms were suitable for endovascular coiling. These patients had unremarkable intraoperative catheterizations and coiling but subsequently deteriorated post-operatively due to mesenteric ischaemia. Two patients required colectomy for mesenteric ischaemia, and the third arrested secondary to sepsis from bowel perforation. We discuss the various causes that may explain this association, and we alert the neurosurgical community for this complication which has not been reported before.

  9. Changes of incompletely embolized aneurysm with tungsten coils : an experimental study in dogs

    International Nuclear Information System (INIS)

    Yu, In Kyu; Han, Moon Hee; Kim, Sung Hyun; Won, Hyung Jin; Chang, Kee Hyun; Yeon, Kyung Mo; Choe, Ghee Young; Kim, Sam Soo

    1999-01-01

    To evaluate changes of residual aneurysms according to the size of aneurysmal neck and thrombogenicity of a tungsten coil after incomplete embolization of experimental lateral aneurysms. Eleven experimental lateral aneurysms with different aneurysmal neck size were created in the common carotid arteries of mongrel dogs. They were then divided into narrow-neck(n=3), wide-neck(n=6) and spontaneously thrombosed control(n=2) groups. After confirmation of aneurysmal patency, incomplete embolizations of varying degrees (about 30% to near total occlusion) were performed using 5mm-diameter tungsten coils. Angiography was performed immediately before and after, and one and six weeks after embolizations. The size of residual aneurysm was measured on each angiogram. After the last angiography embolized aneurysms were excised and examined under light and electron microscopes. On angiograms obtained 6 weeks after embolization, all residual narrow neck aneurysms were completely occluded, whereas in those with a wide-neck, therre was either no change (n=4) or a slight increase in size(n=2). On light microscopy, all narrow-neck aneurysms showed total organized fibrosis while all control aneurysms and half those with a wide neck showed unorganized thrombi. The embolized group showed a higher degree of organization in the aneurysmal cavity than did the control group. Neointima formation was seen in all embolized aneurysms, but no aneurysm showed foreign body reaction. On electron microscopy, uniform thickness of plasma coatings was noted on the surface of the tungsten coils. A wide-neck residual aneurysm may persist or increase in size, while one with a narrow-neck can be thrombosed after incomplete embolization with tungsten coils in a lateral aneurym. Careful consideration might be necessary in the embolization of wide-neck aneurysms. With plasma coatings on its surface and organized fibrosis, tungsten coil can be an useful for embolization of an aneurysm

  10. Indentification of inflow zone of cerebral aneurysm by MRA for effective coil embolization

    International Nuclear Information System (INIS)

    Kudo, Takumi; Satow, Tetsu; Yamada, Naoaki; Hyuga, Takanori; Miyamoto, Susumu; Murao, Kenichi

    2008-01-01

    It is important to pack the inflow zone of intracerebral aneurysm to prevent coil compaction or recanalization after coil embolization of the aneurysm. In this study, we report the usefulness of magnetic resonance angiography (MRA) to identify the inflow zone of the aneurysm. Between November 2004 and March 2006, 21 patients (IC paraclinoid, 11 cases; BA tip, 3 cases; A-com, 4 cases; IC-top, 2 cases; P1, 1 case) underwent interventional coil embolization for cerebral aneurysms and MRA was used to try to depict the inflow zone of the aneurysm. We designed a 3D time-of-flight MRA technique targeted to the aneurysm with a large flip angle to emphasize the streamline into the aneurysm. We grasped the position of the inflow zone in the aneurysm by MRA before intervention. The inflow zone was packed by coils tightly with balloon neck remodeling technique anchor catheter assist technique, if necessary. The inflow zone was depicted in all 21 cases by MRA. In sidewall type aneurysms, the inflow zone existed beside the distal neck in all cases. In terminal type aneurysms, the inflow zone existed on an extension line from patent artery. Dome filling was not detected in all cases after treatment. Small neck remnant was detected in 6 cases that slightly increased in 4 cases, vanished in 1 case, remained and unchanged in 1 case 6 months after treatment. None of the cases required additional treatment. For effective coil embolization, it is important to grasp the position of the inflow zone of the aneurysm and to pack the point as tightly as possible. Identification of the inflow zone of aneurysm by MRA is useful for coil embolization. (author)

  11. Middle and long-term follow-up of intracranial aneurysms treated with Matrix detachable coils

    International Nuclear Information System (INIS)

    Wu Xi; Liu Jianmin; Huang Qinghai; Xu Yi

    2008-01-01

    Objective: This study was undertaken to evaluate the safety of the polyglycolic/polylactic acid (PGLA)-coated Matrix detachable coils (Matrix) and analyze factors which may relate to the recanalization rate of the Matrix coils in the treatment of intracranial aneurysms. Methods: 75 patients underwent 79 aneurysm treatments with Matrix coils from May 2003 to July 2005 were retrospectively investigated. Morphological changes were compared postoperatively with last-follow-up digital subtraction angiography (DSA) by using the Raymond scale. We defined incomplete recanalization or stable aneurysms as uncured, while those of progressive occlusion or complete occlusion aneurysms demonstrated on the last-follow-up imagings as cured. We also utilized Cox model for analyzing the relationships between factors including age, gender, degree of aneurysmal occlusion, stenting, aneurysm neck size, aneurysm maximum size and Matrix coils length (%) and the long-term angiographic follow-up results. Results: The correlative surgical complications rate with Matrix coils was 13.3%. The total rate of recanalization was 11.4%. Large aneurysms treated with combined stenting got 40% recanalization. No statistic relationships were shown between the factors forementioned and the recanalization rate, but progressive occlusion was observed in 11 (61%)incompletely treated aneurysms. Conclusions: Matrix detachable coil technique is safe for intracranial aneurysm and would further decrease the recurrence of large aneurysm with combination of stenting but long term efficacy needs further follow-up and large scale randomized control study. (authors)

  12. Performance of long J-shaped coils in large and giant intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    Tokunaga, K.; Tanaka, N.; Sugiu, K.; Levrier, O.; Martin, J.B.; Ruefenacht, D.A.

    2002-01-01

    We evaluated the performance of long straight coils (Detach-18 trademark J-shaped coils) in large and giant in-vitro aneurysms. The coils consisted of a distal semicircular part 7 or 15 mm in diameter and a proximal 70 cm straight part having three types of stiffness: soft, standard, and stiff. We first investigated the ease of passage through a microcatheter in a realistic cerebral vessel model. Second, we made silicone models simulating lateral-type aneurysms of various spherical dome diameters (12, 15, 20 and 30 mm) and neck sizes (3-10 mm; dome-to-neck ratio approximately 3:1) and connected them to a pulsating circulatory pump. We evaluated the anchoring and folding patterns of the coils, stability of the microcatheter and coils in the aneurysm, and smoothness of delivery and retrieval of coils. Third, we compared the conformability of a coil in a large, irregular aneurysm with that of a spiral coil. The long J-shaped coils were easily advanced and retrieved through a microcatheter in a tortuous vessel model. In 12 mm spherical aneurysms, each coil made a complex framework, and knot formation or damage to the coil during withdrawal was often observed. In 15 mm aneurysms, the coils were all easily delivered and retrieved; standard-stiffness coils adapted best to this size. In 20 mm aneurysms, frameworks were less complex but still good with a standard or stiff coil, but those with soft coil were unstable and changed significantly within 3 min of detachment due to gravity and pulsatile flow. In 30 mm aneurysms, soft coils filled only the lower part during introduction, whereas a stiff coil still made a favourable framework. Conformability of a long J-shaped coil was superior to that of a spiral coil in a large, irregular aneurysm. Long J-shaped coils conform well to various configurations of large and giant aneurysms and can shorten procedures since a larger implant volume can be delivered with a single coil. Their principle of action may promote more favourable

  13. Coil embolization of an enlarging fusiform myxomatous cerebral aneurysm

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2018-04-01

    Full Text Available Myxomatous cerebral aneurysms are rare sequelae of cardiac atrial myxoma. These aneurysms are generally fusiform, multiple, and distal. Pathogenesis and evolution of these aneurysms is still debated. There are currently no guidelines on the management of aneurysms secondary to atrial myxoma. We present a case of a 52-year-old man with multiple fusiform aneurysms 3 years after resection of a left atrial myxoma. One of these aneurysms was followed with cerebral angiography and showed substantial interval enlargement. This aneurysm was subsequently embolized. All aneurysms were stable 6 months post-embolization. Keywords: Myxomatous aneurysm, Fusiform, Coil embolization

  14. Onyx combined with coiling embolization for endovascular treatment of complex intracranial ruptured aneurysms

    International Nuclear Information System (INIS)

    Wu Yongfa; Huang Qinghai; Yang Pengfei; Zhang Lei; Li Qiang; Liu Jianmin

    2011-01-01

    Objective: To study the therapeutic effect of Onyx combined with stent-assisted coiling in embolizing complex intracranial ruptured aneurysms. Methods: Onyx combined with stent-assisted coiling embolization was conducted in two patients with complex intracranial ruptured aneurysms. The clinical data were retrospectively analyzed. The related literature concerning intracranial complex aneurysm treated with Onyx was reviewed. Results: Two intracranial complex aneurysms were embolized with Onyx together with coils. The lesions were located at internal carotid arterial bifurcation (n=1) and at the anterior wall of internal carotid artery (n=1). Complete embolization of the aneurysms was achieved immediately after the procedure while the parent arteries remained patent. Conclusion: For the treatment of complex intracranial ruptured aneurysms Onyx combined with coiling embolization is safe, effective and feasible. This technique can improve the degree of embolization. To make the evaluation of the long-term efficacy further study is needed. (authors)

  15. Double microcatheter technique for coiling intracranial aneurysms with unfavorable configurations

    Directory of Open Access Journals (Sweden)

    WANG Shu-yuan

    2013-03-01

    Full Text Available Background Although stent-assisted technique has been widely used clinically, it is still hard to perform coiling treatment for complicated intracranial aneurysms, including relatively wide-necked tiny aneurysms and lobulated wide-necked aneurys ms with important branch vessels arising from the neck. This study aims to investigate the feasibility and clinical results of endovascular treatment for intracranial aneurysms with unfavorable configurations by using double microcatheter technique. Methods Thirty-three cases with complicated aneurysms were treated by using double microcatheter technique from April 2008 to November 2012. The locations of these aneurysms were anterior communicating artery (7 cases, posterior communicating artery (14 cases, ophthalmic artery (3 cases, anterior choroidal artery (3 cases, origin of posterior inferior cerebellar artery (3 cases, bifurcation of middle cerebral artery (2 cases and top of basilar artery (1 case. The mean neck- to-body (width ratio was 0.80 ± 0.21 (0.53-1.33. The mean body (width-to-dome (height ratio was 1.12 ± 0.37 (0.55-2.12. The mean dome (height-to-neck ratio was 1.26 ± 0.41 (0.65-2.96. The diameter of neck ≥4 mm was seen in 7 aneurysms, neck≥height in 9 and neck ≥width in 8. Besides, there were 9 very small aneurysms (the maximum diameter≤3 mm and 13 aneurysms with important branch vessels arising from the neck. All of these aneurysms were treated with coiling by using double microcatheter technique. Results All aneurysms were successfully embolized. Immediate postembolization angiography showed no residual contrast filling in 19 aneurysms, and residual filling in 14. There were some small loops protruding from the neck without influencing the blood flow in 12 cases. At discharge, according to modified Rankin Scale (mRS, 30 patients with 0-1 scores presented excellent clinical outcomes and 3 patients with 2 scores had cognitive dysfunction and moderate disability due to vasospasm

  16. Treatment of a spontaneous intracranial dissecting aneurysm with stent-assisted coil embolization

    International Nuclear Information System (INIS)

    Irie, Keiko; Negoro, Makoto; Hayakawa, Motoharu; Hayashi, Junichi; Kanno, Tetsuo

    2003-01-01

    Arterial dissection is now recognized as an important cause of stroke. Most reported dissections involve the extracranial portion of the internal carotid artery (ICA) and vertebral arteries. Spontaneous dissecting aneurysms of the intracranial ICA are uncommon. Endovascular treatment for cerebral aneurysms has become widespread; however, the dissecting aneurysm is still difficult to treat if the parent artery has to be preserved. More recently, stenting has been advocated for use with endosaccular coiling, with the coils held in place by the stent. We herein report a spontaneous intracranial ICA dissecting aneurysm in a 51-year-old woman who was treated using a new technique of combined stent and coils. (orig.)

  17. Computational fluid dynamics (CFD) using porous media modeling predicts recurrence after coiling of cerebral aneurysms.

    Science.gov (United States)

    Umeda, Yasuyuki; Ishida, Fujimaro; Tsuji, Masanori; Furukawa, Kazuhiro; Shiba, Masato; Yasuda, Ryuta; Toma, Naoki; Sakaida, Hiroshi; Suzuki, Hidenori

    2017-01-01

    This study aimed to predict recurrence after coil embolization of unruptured cerebral aneurysms with computational fluid dynamics (CFD) using porous media modeling (porous media CFD). A total of 37 unruptured cerebral aneurysms treated with coiling were analyzed using follow-up angiograms, simulated CFD prior to coiling (control CFD), and porous media CFD. Coiled aneurysms were classified into stable or recurrence groups according to follow-up angiogram findings. Morphological parameters, coil packing density, and hemodynamic variables were evaluated for their correlations with aneurysmal recurrence. We also calculated residual flow volumes (RFVs), a novel hemodynamic parameter used to quantify the residual aneurysm volume after simulated coiling, which has a mean fluid domain > 1.0 cm/s. Follow-up angiograms showed 24 aneurysms in the stable group and 13 in the recurrence group. Mann-Whitney U test demonstrated that maximum size, dome volume, neck width, neck area, and coil packing density were significantly different between the two groups (P CFD and larger RFVs in the porous media CFD. Multivariate logistic regression analyses demonstrated that RFV was the only independently significant factor (odds ratio, 1.06; 95% confidence interval, 1.01-1.11; P = 0.016). The study findings suggest that RFV collected under porous media modeling predicts the recurrence of coiled aneurysms.

  18. Periprocedural safety of aneurysm embolization with the Medina Coil System: the early human experience.

    Science.gov (United States)

    Turk, Aquilla S; Maia, Orlando; Ferreira, Christian Candido; Freitas, Diogo; Mocco, J; Hanel, Ricardo

    2016-02-01

    Intracranial saccular aneurysms, if untreated, carry a high risk of morbidity and mortality from intracranial bleeding. Embolization coils are the most common treatment. We describe the periprocedural safety and performance of the initial human experience with the next generation Medina Coil System. The Medina Coil System is a layered three-dimensional coil made from a radiopaque, shape set core wire, and shape memory alloy outer coil filaments. Nine aneurysms in five patients were selected for treatment with the Medina Coil System. Nine aneurysms in five patients, ranging from 5 to 17 mm in size in various locations, were treated with the Medina Coil System. No procedural or periprocedural complications were encountered. Procedure times, number of coils used to treat the aneurysm, and use of adjunctive devices were much less than anticipated if conventional coil technology had been used. The Medina Coil System is a next generation coil that combines all of the familiar and expected procedural safety and technique concepts associated with conventional coils. We found improved circumferential aneurysm filling, which may lead to improved long term outcomes, with fewer devices and faster operating times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

    Science.gov (United States)

    Liu, Jian; Jing, Linkai; Wang, Chao; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-11-01

    Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. A coil placement technique to treat intracranial aneurysm with incorporated artery

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2018-03-01

    Conclusion: This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs.

  1. Comparison of Enterprise with Neuroform stent-assisted coiling of intracranial aneurysms.

    Science.gov (United States)

    Kadkhodayan, Yasha; Rhodes, Nicholas; Blackburn, Spiros; Derdeyn, Colin P; Cross, DeWitte T; Moran, Christopher J

    2013-04-01

    The Enterprise stent is the first closed-cell stent designed to treat wide-necked intracranial aneurysms. Advantages of the design can include improvement in keeping coils within an aneurysm and the ability of the stent to be recaptured. We compared the technical and clinical complications of the Enterprise stent with the open-cell Neuroform stent, its primary alternative. Patients undergoing Enterprise and Neuroform stent-assisted aneurysm coiling were enrolled in prospective registries starting in March 2007 and February 2003, respectively. All consecutive patients through December 2011 were included. Deployment success and difficulty, stent movement and misplacement, and procedural complications were compared. Enterprise deployment success was high (108 of 115 attempts, 93.9%) with 102 aneurysms receiving a stent compared with Neuroform (173 of 214 attempts, 80.8%, p = 0.001) with 163 aneurysms. Enterprise was easier to deploy (1.7% vs 15.9% difficult deployment, p Enterprise stent (8.7% vs 1.4%, p = 0.0021). The Enterprise stent enabled treatment of 10 additional aneurysms that could not be treated with Neuroform and had a higher rate of immediate aneurysm occlusion (87.3% vs 73.0%, p = 0.0058). Enterprise was easier to deploy and enabled treatment of additional aneurysms; however, there were more thromboembolic complications. On the basis of these findings, we prefer to use the Neuroform stent first and rely on the Enterprise stent as an easy-to-deliver backup for stent-assisted coiling.

  2. In vitro study of near-wall flow in a cerebral aneurysm model with and without coils.

    Science.gov (United States)

    Goubergrits, L; Thamsen, B; Berthe, A; Poethke, J; Kertzscher, U; Affeld, K; Petz, C; Hege, H-C; Hoch, H; Spuler, A

    2010-09-01

    Coil embolization procedures change the flow conditions in the cerebral aneurysm and, therefore, in the near-wall region. Knowledge of these flow changes may be helpful to optimize therapy. The goal of this study was to investigate the effect of the coil-packing attenuation on the near-wall flow and its variability due to differences in the coil structure. An enlarged transparent model of an ACA aneurysm was fabricated on the basis of CT angiography. The near-wall flow was visualized by using a recently proposed technique called Wall-PIV. Coil-packing attenuation of 10%, 15%, and 20% were investigated and compared with an aneurysmal flow without coils. Then the flow variability due to the coil introduction was analyzed in 10 experiments by using a packing attenuation of 15%. A small packing attenuation of 10% already alters the near-wall flow significantly in a large part of the aneurysmal sac. These flow changes are characterized by a slow flow with short (interrupted) path lines. An increased packing attenuation expands the wall area exposed to the altered flow conditions. This area, however, depends on the coil position and/or on the 3D coil structure in the aneurysm. To our knowledge, this is the first time the near-wall flow changes caused by coils in an aneurysm model have been visualized. It can be concluded that future hydrodynamic studies of coil therapy should include an investigation of the coil structure in addition to the coil-packing attenuation.

  3. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    DEFF Research Database (Denmark)

    Wernheden, Erika; Brenøe, Anne Sofie; Shahidi, Saeid

    2017-01-01

    Splenic artery aneurysms (SAAs) are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm) SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured...... 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA....

  4. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization

    International Nuclear Information System (INIS)

    Li, Ming-Hua; Gao, Bu-Lang; Fang, Chun; Cheng, Ying-Sheng; Li, Yong-Dong; Wang, Jue; Xu, Guo-Ping

    2006-01-01

    Intracranial aneurysm rupture during embolization with detachable coils is reportedly among the gravest of intraprocedural complications. We present here our experiences with this outcome, and a potential intervention for managing this life-threatening complication. From April 1998 to March 2005, 284 patients with cerebral aneurysms were treated with detachable coils. Intraprocedural aneurysm rupture occurred in ten patients with a history of a previously ruptured aneurysm. In the event of intraprocedural hemorrhage, we routinely performed heparin reversal with protamine sulfate. Of the 221 patients with a previously ruptured aneurysm, intraprocedural aneurysm rupture occurred in 10 (4.5%). These ruptures were caused by a microguidewire in one patient, a microcatheter in one, over-packing in two and a coil perforation in three. In the remaining three patients the ruptures were caused by both the microcatheter and the coils. Three patients died because of aneurysm re-rupture, yielding a mortality rate of 30%. One patient presented with a slight disability in the left leg and no neurological deficits were observed in the remaining six patients. Intraprocedural aneurysm rupture during embolization is a rare, but unavoidable and life-threatening event. Proper measures should be taken to reduce and improve the outcome of this tragic occurrence. The majority of patients with an intraprocedural ruptured aneurysm can survive without severe sequelae if managed appropriately. (orig.)

  5. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    Directory of Open Access Journals (Sweden)

    Erika Wernheden, MD

    2017-12-01

    Full Text Available Splenic artery aneurysms (SAAs are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA.

  6. Abciximab for thrombolysis during intracranial aneurysm coiling

    International Nuclear Information System (INIS)

    Gralla, Jan; Rennie, Adam T.M.; Corkill, Rufus A.; Lalloo, Shivendra T.; Molyneux, Andrew; Byrne, James V.; Kuker, Wilhem

    2008-01-01

    Thrombotic events are a common and severe complication of endovascular aneurysm treatment with significant impact on patients' outcome. This study evaluates risk factors for thrombus formation and assesses the efficacy and safety of abciximab for clot dissolution. All patients treated with abciximab during (41 patients) or shortly after (22 patients) intracranial aneurysm coil embolisation were retrieved from the institutional database (2000 to 2007, 1,250 patients). Sixty-three patients (mean age, 55.3 years, ±12.8) had received either intra-arterial or intravenous abciximab. Risk factors for clot formation were assessed and the angiographic and clinical outcome evaluated. No aneurysm rupture occurred during or after abciximab application. The intra-procedural rate of total recanalisation was 68.3%. Thromboembolic complications were frequently found in aneurysms of the Acom complex and of the basilar artery, whilst internal carotid artery aneurysms were underrepresented. Two patients died of treatment-related intracranial haemorrhages into preexisting cerebral infarcts. Two patients developed a symptomatic groin haematoma. Abciximab is efficacious and safe for thrombolysis during and after endovascular intracranial aneurysm treatment in the absence of preexisting ischaemic stroke. (orig.)

  7. Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis.

    Science.gov (United States)

    Kühn, Anna Luisa; Hou, Samuel Y; Puri, Ajit S; Silva, Christine F; Gounis, Matthew J; Wakhloo, Ajay K

    2016-06-01

    Stent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm). To present our experience with stents approved for SACE in aneurysms with small parent arteries. All patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data. A total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2-2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months' follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months' follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up. Our results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. MR angiography after coiling of intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, J.D.

    2012-01-01

    Introduction Endovascular occlusion with detachable coils has become an alternative treatment to neurosurgical clipping of intracranial aneurysms over the last two decades. Its minimal invasiveness is the most important advantage of this treatment compared to clipping. The disadvantage of occlusion

  9. Endovascular treatment of posterior cerebral artery aneurysms using detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Konkuk University Hospital, Department of Radiology, Seoul (Korea); Kim, Sam Soo; Han, Heon [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Kang, Hyun-Seung [Konkuk University Hospital, Department of Neurosurgery, Seoul (Korea); Moon, Won-Jin [Konkuk University Hospital, Department of Radiology, Seoul (Korea); Byun, Hong Sik [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea)

    2008-03-15

    Aneurysms of the posterior cerebral artery (PCA) are rare, and most of the studies reported in the literature in which the endovascular approach was applied were carried out on a limited number of patients with PCA aneurysms. We retrospectively reviewed our cases of PCA aneurysms - at various locations and of differing shapes - that received endovascular treatment and evaluated the treatment outcome. From January 1996 to December 2006, 13 patients (eight females and five males) with 17 PCA aneurysms (nine fusiform and eight saccular) were treated using the endovascular approach. The age of the patients ranged from 20 to 67 years, with a mean age of 44 years. Of the 13 patients, ten presented with intracranial hemorrhage, and one patient, with a large P2 aneurysm, presented with trigeminal neuralgia; the aneurysms were asymptomatic in the remaining two patients. All 13 patients were successfully treated, with only one procedure-related symptomatic complication. Seven patients were treated by occlusion of the aneurysm and parent artery together; five patients, by selective embolization of the aneurysm; one patient, by partial coiling. Although infarctions were found in two patients treated with selective embolization and in three patients treated with parent artery occlusion, only one patient with a ruptured P2 aneurysm treated with parent artery occlusion developed transient amnesia as an ischemic symptom. Posterior cerebral artery aneurysms can be treated safely with either occlusion of the aneurysm together with the PCA or with a selective coil embolization. Infarctions may occur after endovascular treatment, but they are rarely the cause of a disabling symptom. (orig.)

  10. Temporal cascade of inflammatory cytokines and cell-type populations in monocyte chemotactic protein-1 (MCP-1)-mediated aneurysm healing.

    Science.gov (United States)

    Hoh, Brian L; Fazal, Hanain Z; Hourani, Siham; Li, Mengchen; Lin, Li; Hosaka, Koji

    2018-03-01

    We have previously shown that monocyte chemotactic protein-1 (MCP-1) promotes aneurysm healing. To determine the temporal cascade and durability of aneurysm healing. Murine carotid aneurysms were treated with MCP-1-releasing or poly(lactic-co-glycolic) acid (PLGA)-only coils. Aneurysm healing was assessed by quantitative measurements of intraluminal tissue ingrowth on 5 μm sections by blinded observers. Aneurysm healing occurred in stages characteristic of normal wound healing. The 1st stage (day 3) was characterized by a spike in neutrophils and T cells. The 2nd stage (week 1) was characterized by an influx of macrophages and CD45+ cells significantly greater with MCP-1 than with PLGA (p<0.05). The third stage (week 2-3) was characterized by proliferation of smooth muscle cells and fibroblasts (greater with MCP-1 than with PLGA, p<0.05). The fourth stage (3-6 months) was characterized by leveling off of smooth muscle cells and fibroblasts. M1 macrophages were greater at week 1, whereas M2 macrophages were greater at weeks 2 and 3 with MCP-1 than with PLGA. Interleukin 6 was present early and increased through week 2 (p<0.05 compared with PLGA) then decreased and leveled off through 6 months. Tumour necrosis factor α was present early and remained constant through 6 months. MCP-1 and PLGA treatment had similar rates of tissue ingrowth at early time points, but MCP-1 had a significantly greater tissue ingrowth at week 3 (p<0.05), which persisted for 6 months. The sequential cascade is consistent with an inflammatory model of injury, repair, and remodeling. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have?

    International Nuclear Information System (INIS)

    Kurre, W.; Berkefeld, J.

    2008-01-01

    Since coils were approved for aneurysm treatment, materials and techniques developed rapidly. It still remains an open question whether one material or method is superior. This article reviews the literature on various coil types and treatment approaches assessing the scientific evidence of its use. Studies on aneurysm treatment with Guglielmi detachable platinum coils, bioactive coils, hydrogel coated coils, and complex designs as well as balloon- and stent-assisted techniques were retrieved by a PubMed database search from 1990 until May 2008. Data were analyzed in terms of aneurysm occlusion, permanent morbidity and mortality, recanalization, and retreatment. We also assessed the level of evidence of the published studies. Only the International Subarachnoid Aneurysm Trial provides level I evidence proving the superiority of endovascular over surgical therapy in ruptured aneurysms. Randomized trials comparing bioactive or hydrogel coated devices with bare coils are ongoing. Other studies were based on registries or case series mainly conducted without control groups. Morbidity, mortality, and initial occlusion rates appear similar for all devices. No clear evidence exists for the superiority of bioactive- or hydrocoils regarding long-term stability. It remains ambiguous whether morbidity and mortality rises with the use of balloons and stents. There is no evidence that routine use of balloons improves treatment durability. Mid-term results of stent-assisted coiling of complex aneurysms appear favorable. There is a lack of studies with a high level of evidence comparing different coiling materials and techniques. Case series and registries were not able to prove the superiority of any device or method. (orig.)

  12. Procedure-related haemorrhage in embolisation of intracranial aneurysms with Guglielmi detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, B.J.; Kim, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Han, M.H.; Chang, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Clinical Research Institute, Seoul National University Hospital, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Institute of Radiation Medicine, Seoul National University Medical Research Centre, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Seoul National University College of Medicine (Korea); Oh, C.W. [Department of Neurosurgery, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea)

    2003-08-01

    We reviewed the haemorrhagic complications of the endovascular treatment of intracranial aneurysms, in terms of frequency, pre-embolisation clinical status, clinical and radiological manifestations, management and prognosis. In 275 patients treated for 303 aneurysms over 7 years we had seven (one man and six women - 2.3%) with haemorrhage during or immediately after endovascular treatment. All procedures were performed with a standardised protocol of heparinisation and anaesthesia. Four had ruptured aneurysms, two at the tip of the basilar artery, and one ach on the internal carotid and posterior cerebral artery, treated after 12, 5, 14, and 2 days, respectively, three were in Hunt and Hess grade 2 and one in grade 1. Bleeding occurred during coiling in three, after placement of at least four coils, and during manipulation of the guidewire to enter the aneurysm in the fourth. Haemorrhage was manifest as extravasation of contrast medium, with a sudden rise in systolic blood pressure in three patients. The other three patients had unruptured aneurysms; they had stable blood pressure and angiographic findings during the procedure, but one, under sedation, had seizures immediately after insertion of four coils, and the other two had seizures, headache and vomiting on the day following the procedure. Heparin reversal with protamine sulphate was started promptly started when bleeding was detected in four patients, and the embolisation was completed with additional coils in three. Emergency ventricular drainage was performed in the two patients with ruptured aneurysm and one with an unruptured aneurysm who had abnormal neurological responses or hydrocephalus. The bleeding caused a third nerve palsy in one patient, which might have been due to ischaemia and progressively improved. (orig.)

  13. Coil embolization of mycotic pulmonary artery aneurysm: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeen Woo; Lee, Jae Kyo; Hwang, Mi Soo; Cho, Kil Ho [College of Medicine, Yeungnam University, Taegu (Korea, Republic of)

    2000-02-01

    Aneurysms of the pulmonary artery are rare, with mycotic aneurysms occurring most frequently. This latter type may also occur in association with a lung abscess or septicemia, particularly in drug addicts. As far as we are aware, the radiologic findings of mycotic aneurysm of the pulmanary artery have not been reported in Korea. We present the simple chest radiographs, as well as the CT and angiographic findings, of a case of aneurysm of the pulmonary artery which was successfully embolized using a coil. (author)

  14. Coil embolization of mycotic pulmonary artery aneurysm: a case report

    International Nuclear Information System (INIS)

    Kim, Jeen Woo; Lee, Jae Kyo; Hwang, Mi Soo; Cho, Kil Ho

    2000-01-01

    Aneurysms of the pulmonary artery are rare, with mycotic aneurysms occurring most frequently. This latter type may also occur in association with a lung abscess or septicemia, particularly in drug addicts. As far as we are aware, the radiologic findings of mycotic aneurysm of the pulmanary artery have not been reported in Korea. We present the simple chest radiographs, as well as the CT and angiographic findings, of a case of aneurysm of the pulmonary artery which was successfully embolized using a coil. (author)

  15. Clinical Application of Insertion Force Sensor System for Coil Embolization of Intracranial Aneurysms.

    Science.gov (United States)

    Matsubara, Noriaki; Miyachi, Shigeru; Izumi, Takashi; Yamada, Hiroyuki; Marui, Naoki; Ota, Keisuke; Tajima, Hayato; Shintai, Kazunori; Ito, Masashi; Imai, Tasuku; Nishihori, Masahiro; Wakabayashi, Toshihiko

    2017-09-01

    In endovascular embolization for intracranial aneurysms, it is important to properly control the coil insertion force. However, the force can only be subjectively detected by the subtle feedback experienced by neurointerventionists at their fingertips. The authors envisioned a system that would objectively sense and quantify that force. In this article, coil insertion force was measured in cases of intracranial aneurysm using this sensor, and its actual clinical application was investigated. The sensor consists of a hemostatic valve (Y-connector). A little flexure was intentionally added in the device, and it creates a bend in the delivery wire. The sensor measures the change in the position of the bent wire depending on the insertion force and translates it into a force value. Using this, embolization was performed for 10 unruptured intracranial aneurysms. The sensor adequately recorded the force, and it reflected the operators' usual clinical experience. The presence of the sensor did not affect the procedures. The sensor enabled the operators to objectively note and evaluate the insertion force and better cooperative handling was possible. Additionally, other members of the intervention team shared the information. Force records demonstrated the characteristic patterns according to every stage of coiling (framing, filling, and finishing). The force sensor system adequately measured coil insertion force in intracranial aneurysm coil embolization procedures. The safety of this sensor was demonstrated in clinical application for the limited number of patients. This system is useful adjunct for assisting during coil embolization for an intracranial aneurysm. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. MR angiography in the follow-up of coiled cerebral aneurysms after treatment with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Nome, T.; Bakke, S. J.; Nakstad, P. H.

    2002-01-01

    Purpose: Intra-arterial digital subtraction angiography (DSA) has been considered the gold standard examination in the follow-up of patients treated with Guglielmi detachable coils (GDCs). However, DSA is an invasive and expensive investigation and results in exposure to ionising radiation to both patient and operator. The aim of this study was to compare MR angiography (MRA) with DSA with regard to patency of the occlusion of aneurysms following GDC treatment. Material and Methods: We performed 75 MRA and DSA examinations on 51 patients treated with GDCs. The examinations were performed 3-36 months after embolisation and the interval between MRA and DSA was less than 1 week. Hard copies of both studies were interpreted retrospectively and independently for residual flow within the aneurysm, residual aneurysmal neck, and parent and branch vessel flow. Results: Patency status of parent and branch vessel flow was correctly identified with MRA in all patients except 1. The sensitivity of MRA in revealing residual flow within the aneurysm was 97%. The specificity in ruling out residual flow within the aneurysm was 91%. Conclusion: MRA may replace DSA in the long-term follow-up of coiled cerebral aneurysms. The initial follow-up examination should, however, include both modalities

  17. Stent-assisted coil embolization for cavernous carotid artery aneurysms.

    Science.gov (United States)

    Kono, Kenichi; Shintani, Aki; Okada, Hideo; Tanaka, Yuko; Terada, Tomoaki

    2014-01-01

    Internal carotid artery (ICA) occlusion with or without a bypass surgery is the traditional treatment for cavernous sinus (CS) aneurysms with cranial nerve (CN) dysfunction. Coil embolization without stents frequently requires retreatment because of the large size of CS aneurysms. We report the mid-term results of six unruptured CS aneurysms treated with stent-assisted coil embolization (SACE). The mean age of the patients was 72 years. The mean size of the aneurysms was 19.8 mm (range: 13-26 mm). Before treatment, four patients presented with CN dysfunction and two patients had no symptoms. SACE was performed under local or general anesthesia in three patients each. Mean packing density was 29.1% and tight packing was achieved. There were no neurological complications. CN dysfunction was cured in three patients (75%) and partly resolved in one patient (25%). Transient new CN dysfunction was observed in two patients (33%). Clinical and imaging follow-up ranged from 6 to 26 months (median: 16 months). Recanalization was observed in three patients (50%; neck remnant in two patients and dome filling in one patient), but no retreatment has yet been required. No recurrence of CN dysfunction has occurred yet. In summary, SACE increases packing density and may reduce requirement of retreatment with an acceptable cure rate of CN dysfunction. SACE may be a superior treatment for coiling without stents and be an alternative treatment of ICA occlusion for selected patients, such as older patients and those who require a high-flow bypass surgery or cannot receive general anesthesia.

  18. Rebleeding of a Splenic Artery Aneurysm after Coil Embolisation

    Directory of Open Access Journals (Sweden)

    Kyra D. Kingma

    2016-01-01

    Full Text Available Background. Splenic artery aneurysm (SAA is an uncommon and difficult diagnosis. SAA is more common in females. Only 20% of SAA is symptomatic and may present as a rupture. A ruptured SAA is associated with a 25% mortality rate. Case Presentation. We present a case of a male patient with a bleeding SAA that rapidly increased in size. Distal coiling was technically impossible and despite proximal coil embolisation the SAA continued to bleed. A laparotomy including splenectomy and partial pancreatectomy was performed with an uneventful patient recovery. Discussion. Endovascular management is currently considered the optimal treatment of SAA. However, careful monitoring and follow-up is needed after embolisation as rapid recanalization of the SAA may possibly occur, especially when distal coiling of the aneurysm is unsuccessful. Conclusion. Endovascular treatment of an SAA is not necessarily effective. Surgeons must be prepared to perform open procedures to further reduce mortality rates.

  19. Treatment of intracranial wide neck aneurysm with neuroform self-expanding stent combined with spring coils

    International Nuclear Information System (INIS)

    Bai Weixing; Jiang Xifeng; Li Tianxiao; Zhai Shuiting; Xue Jiangyu; Wang Ziliang; Cao Huicun

    2008-01-01

    Objective: To evaluate the preliminary experience of the combined self-expanding neurovascular stent (Neuroform stent) with detachable coils in the management of intracranial wide neck aneurysms. Methods: Self-expanding neurovascular stents with detachable coils were used in treating 27 intracranial wide neck aneurysms of 25 patients including cavernous segment ICA aneurysms in 3, ophthalmic arterial anemysm in 1, PcomA in 18, AcomA in 2, MCAM1 in 1, MCA bifurcation in 1, and basilar trunk in 1. Among them, 2 cases consisted of multi-aneurysms, 2 aneurysms coincide with absolute wide neck (> 4 mm) and 6 with comparatively wide neck (> 7 mm). Nemoform stents were deployed across the neck of aneurysm and detachable coils were released to embolize the aneurysm through stent mesh. Results: Twenty-six Neuroform stents were successfully deployed in 25 patients including 4 Neuroform II stents, and 22 Neurofom III stents(all combined with spring coils). Total occlusion was achieved in 7 patients with residual neck in 9 nearly complete occlusion and partial occlusion in 11. 2 patients were rebleeding and other 2 showed intra-stent thrombosis during the operations. The latter 2 included 1 with post-operative limb paraplegia and 1 died. Still another 1 had transient ischemic attack after the operation. Twenty-three patient recovered well. Twenty-four patients were under clinical followed up from 0.5 to 28 months with an average of 10.8 months. There was no bleeding. Three patients were angiographically followed up for 3-6 months after the procedure, with only 1 case of in-stent thrombosis and no change in other 2 aneurysms with neck remnant. Conclusions: The Neuroform stent is technically feasible and safe for treating intracranial wide neck aneurysms unsuitable for clipping because of its prevention for coil protruding into parent artery. The long term effect still need to be further investigated. (authors)

  20. International Subarachnoid Aneurysm Trial 2009 : Endovascular Coiling of Ruptured Intracranial Aneurysms Has No Significant Advantage Over Neurosurgical Clipping

    NARCIS (Netherlands)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Groen, Rob J. M.; Mooij, Jan Jakob A.; Van Dijk, J. Marc C.

    In the May 2009 issue of The Lancet Neurology, the 5-year follow-up results of the International Subarachnoid Aneurysm Trial (ISAT) were published. The authors concluded that, although the significant difference between coiling and neurosurgical clipping of ruptured intracranial aneurysms in terms

  1. Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils in a canine model

    International Nuclear Information System (INIS)

    Liu Jianmin; Zhang Xin; Zhou Xiaoping; Hong Bo; Xu Yi; Huang Qinghai; Zhang Long; She Jiagui; Zhao Rui

    2004-01-01

    Objective: To assess hemodynamics and histology of the aneurysms by treating experimental wide-necked aneurysms endovascularly with a combination of stents and electrolytic detachable coils. Methods: An experimental model was surgically constructed in the necks of six canines for simulating intracranial wide-necked aneurysms. Balloon-expandable metal stents were positioned across the aneurysms in bilateral carotid arteries of six canines with additional intraaneurysmal placement of detachable microcoils in only unilateral carotid artery of each canine. Sonography and angiography were performed in different stages and histologic examinations were achieved finally. Results: Stent placement was successful in all six canines. Aneurysms treated with only stents placement showed no significant thrombus formation with slow growing of neointima over the neck of the aneurysm. Thrombosis occurred in the aneurysms treated with stents and coils in a short time and neointima covered the neck of the aneurysms completely. Conclusions: Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils may prevent re-rupture of the aneurysms and promote neointima formation over the neck of the aneurysms. (authors)

  2. Y-configuration double-stent-assisted coiling using two closed-cell stents for wide-neck basilar tip aneurysms.

    Science.gov (United States)

    Jeon, Pyoung; Kim, Byung Moon; Kim, Dong Joon; Kim, Dong I K; Park, Keun Young

    2014-09-01

    This study aimed to evaluate clinical and angiographic outcomes of Y-configuration double-stent-assisted (Y-stent) coiling using two closed-cell stents for wide-necked basilar tip aneurysm (BTA). A total of 25 patients underwent Y-stent coiling using two closed-cell stents as a first-time treatment in 18 (3 ruptured) BTAs, retreatment in 2 BTAs and as a third treatment in 5 wide-necked BTAs. Clinical and angiographic outcomes were evaluated retrospectively. Treatment-related complications were three (12.0 %) thromboembolic infarctions due to two acute in-stent thromboses and one embolism. Twenty-two (88 %) patients had favorable outcomes (modified Rankin scale score [mRS], 0-2) during the follow-up period (mean, 30 months; range, 6-54 months). Two patients died: one from initial subarachnoid hemorrhage and the other from intracerebral hemorrhage due to underlying Moyamoya disease. Post-treatment angiograms showed complete occlusion in nine aneurysms, residual neck in 11 aneurysms and residual sac in five aneurysms. Follow-up angiograms were available at least once between 5 to 34 months (mean, 16 months) in 21 patients. Nineteen patients showed improved or stable states (complete occlusion, n = 17; residual neck, n = 2). Major recurrences occurred in two BTAs (9.5 %). Those two major recurrent aneurysms had been large-sized aneurysms at the initial coiling procedure. Both showed not only coil compaction but also progressive growth to giant-sized aneurysms and intra-aneurysmal thrombus formation at the Y-stent coiling as a third-time treatment. Y-stent coiling using two closed-cell stents is a safe and durable treatment option for wide-necked BTA, but may have limited efficacy for large/giant sized and thrombosed aneurysms.

  3. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  4. Coil embolization of anterior circulation aneurysms supported by the solitaire trademark AB neurovascular remodeling device

    International Nuclear Information System (INIS)

    Klisch, Joachim; Clajus, Christin; Sychra, Vojtech; Eger, Cornelia; Strasilla, Christoph; Rosahl, Steffen; Gerlach, Ruediger; Baer, Ingrid; Hoch, Heinrich; Herbon, Uta; Borota, Ljubisa; Jonasson, Per; Liebig, Thomas

    2010-01-01

    The purpose of the study is to evaluate patients with wide-necked or complex aneurysms of the anterior circulation who underwent Solitaire trademark AB Neurovascular Remodeling Device-assisted coil embolization. From February 2008 to March 2009, consecutive data were collected from 45 patients with anterior circulation aneurysms. Eighteen of the patients presented with acute subarachnoid hemorrhage. Forty-six aneurysms were treated with the aid of different applications (n=49) of the Solitaire trademark AB Remodeling Device followed by standard coiling procedure (n = 43) using bioactive coils or/and bare coils. Successful positioning of the remodeling device was obtained in 95.9% of the cases. There were two thromboembolic complications (4.1%) and one severe vasospasm requiring retrieval of the device. Permanent procedural morbidity was observed in one patient (2%). The proportion of patients in whom Raymond class 1 occlusion was obtained was 53.5% (n=23). Raymond class 2 occlusion was achieved in 42% (n=18) and Raymond class 3 occlusion in 4.7% (n=2). Thirty-nine patients left the hospital with a good clinical status. The initial technical and clinical results of Solitaire trademark AB device-assisted coiling of aneurysms in the anterior circulation are highly encouraging. This technique may enhance the possibilities of the endovascular treatment of these aneurysms in clinical routine. (orig.)

  5. Anterior communicating artery aneurysm clipping versus coiling: a comparative study of 50 cases

    Directory of Open Access Journals (Sweden)

    Kumar Pradeep

    2017-09-01

    Full Text Available Introduction: Aneurysmal Subarachnoid Hemorrhage (aSAH remains a devastating and often fatal form of stroke. The aneurysm is targeted for obliteration to prevent re-bleeding and to manage the possible complications from the event. Endovascular coiling has emerged as a less invasive alternative to conventional surgical clipping to treat aneurysms.

  6. Unruptured aneurysms with cranial nerve symptoms: efficacy of endosaccular guglielmi detachable coil treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Joon; Kim, Dong Ik; Lee, Seung Koo; Kim, Si Yeon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2003-09-01

    To evaluate the efficacy of endosaccular Guglielmi detachable coil (GDC) treatment of unruptured aneurysms causing cranial nerve (CN) symptoms. Among a database of 218 patients whose aneurysms were treated using GDC, seven patients met the criteria for unruptured aneurysms presenting with symptoms and signs of CN palsy. Changes in CN symptoms before and after GDC treatment were reviewed. Aneurysms were located in the internal carotid-posterior communicating artery (n=3), the basilar bifurcation (n=1) and the cavernous internal carotid artery (n=3). CN symptoms included ptosis (n=6), mydriasis (n=2), and extraocular muscle (EOM) disorder (CN III: n=4; CN VI: n=3). Overall, improvement or resolution of CN symptoms after treatment was noted in five patients. CN symptoms in cases involving small (10 mm) and intradural aneurysms tended to respond better to GDC treatment. Ptosis was the initial symptom to show improvement, while EOM dysfunction responded least favourably. GDC coil packing appears to be an appropriate treatment method for the relief of CN symptoms associated with intracranial aneurysms.

  7. Unruptured aneurysms with cranial nerve symptoms: efficacy of endosaccular guglielmi detachable coil treatment

    International Nuclear Information System (INIS)

    Kim, Dong Joon; Kim, Dong Ik; Lee, Seung Koo; Kim, Si Yeon

    2003-01-01

    To evaluate the efficacy of endosaccular Guglielmi detachable coil (GDC) treatment of unruptured aneurysms causing cranial nerve (CN) symptoms. Among a database of 218 patients whose aneurysms were treated using GDC, seven patients met the criteria for unruptured aneurysms presenting with symptoms and signs of CN palsy. Changes in CN symptoms before and after GDC treatment were reviewed. Aneurysms were located in the internal carotid-posterior communicating artery (n=3), the basilar bifurcation (n=1) and the cavernous internal carotid artery (n=3). CN symptoms included ptosis (n=6), mydriasis (n=2), and extraocular muscle (EOM) disorder (CN III: n=4; CN VI: n=3). Overall, improvement or resolution of CN symptoms after treatment was noted in five patients. CN symptoms in cases involving small (10 mm) and intradural aneurysms tended to respond better to GDC treatment. Ptosis was the initial symptom to show improvement, while EOM dysfunction responded least favourably. GDC coil packing appears to be an appropriate treatment method for the relief of CN symptoms associated with intracranial aneurysms

  8. Stent-assisted coil embolization of intracranial aneurysms: A single center experience

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2012-07-01

    Conclusion: Despite a modest procedural complication rate, and some evidence of aneurismal recurrence, SACE was proved to be both effective and safe in managing wide-neck intracranial aneurysms. Our results also demonstrated the midterm durability and stability of aneurysm treated by SACE. Furthermore, SACE can be a salvageable procedure in cases with coil instability after detachment.

  9. Fatal rebleeding following coil embolization of cerebral aneurysms: the role of long-term systemic anticoagulation

    International Nuclear Information System (INIS)

    Sinson, G.; Bagley, L.J.; Hurst, R.W.; Flamm, E.S.

    2001-01-01

    Embolization of cerebral aneurysms has become a common technique. Its impact on subsequent medical management of the patient is not well known. We report two patients who presented in a poor neurological grade after subarachnoid hemorrhage from posterior communicating artery aneurysms. Both were treated by coil embolization and both developed subclavian vein thrombosis, requiring systemic anticoagulation, initiated 11 and 21 days after embolization, respectively. Both developed a large, fatal intracranial hemorrhage adjacent to the embolized aneurysm in the fourth week of anticoagulation. Systemic anticoagulation of patients who have had a ruptured aneurysm treated by coil embolization may carry a significant risk of rebleeding. Alternate management strategies should be considered in these patients. (orig.)

  10. Fatal rebleeding following coil embolization of cerebral aneurysms: the role of long-term systemic anticoagulation

    Energy Technology Data Exchange (ETDEWEB)

    Sinson, G. [Dept. of Neurosurgery, University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Bagley, L.J.; Hurst, R.W. [Dept. of Radiology-Neuroradiology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Flamm, E.S. [Hyman-Newman Institute for Neurology and Neurosurgery, New York, NY (United States)

    2001-05-01

    Embolization of cerebral aneurysms has become a common technique. Its impact on subsequent medical management of the patient is not well known. We report two patients who presented in a poor neurological grade after subarachnoid hemorrhage from posterior communicating artery aneurysms. Both were treated by coil embolization and both developed subclavian vein thrombosis, requiring systemic anticoagulation, initiated 11 and 21 days after embolization, respectively. Both developed a large, fatal intracranial hemorrhage adjacent to the embolized aneurysm in the fourth week of anticoagulation. Systemic anticoagulation of patients who have had a ruptured aneurysm treated by coil embolization may carry a significant risk of rebleeding. Alternate management strategies should be considered in these patients. (orig.)

  11. Follow-up observation of intracranial aneurysms with Guglielmi detachable coil embolization

    International Nuclear Information System (INIS)

    Li Minghua; Cheng Yingsheng; Gu Binxian; Chen Junyan; Wang Wu; Xu Tao; Xu Shiding; Liu Jianmin; Xu Yi

    2002-01-01

    Objective: To evaluate the middle-long term efficacy of intracranial aneurysms with Guglielmi detachable Coil (GDC) embolization. Methods: 131 cases with 134 aneurysms were embolized with GDC. Of them, 39 aneurysms were in the anterior communication artery, 45 in the posterior communication artery, 19 in the siphon segment of internal carotid artery, 14 in the mediate cerebral artery, 3 in the anterior cerebral artery, 9 in the posterior circle and 5 in other. A wide-neck (neck > 4 mm, or aneurysm body/neck 2 = 8.643, P < 0.01. Follow-up DSA showed no change in 118 aneurysms which were a total or nearly total occlusion on post-embolization DSA. In 16 aneurysms with subtotal or partial occlusion, re-open of aneurysm showed in 9 cases, reduced in 3, no change in 4 on follow-up DSA. Conclusion: Although the recent-medium-term efficacy of intracranial aneurysms with GDC embolization is in the affirmative, a period follow-up DSA is essential, especially in aneurysms with subtotal or partial occlusion. Again, re-embolization with GDC is recommended in a re-open aneurysm

  12. Aneurysm coil embolization: cost per volumetric filling analysis and strategy for cost reduction.

    Science.gov (United States)

    Wang, Charlie; Ching, Esteban Cheng; Hui, Ferdinand K

    2016-05-01

    One of the primary device expenditures associated with the endovascular treatment of aneurysms is that of detachable coils. Analyzing the cost efficiency of detachable coils is difficult, given the differences in design, implantable volume, and the presence of additives. However, applying a volume per cost metric may provide an index analogous to unit price found in grocery stores. The price information for 509 different coils belonging to 31 different coil lines, available as of September 2013, was obtained through the inventory management system at the study site, and normalized to the price of the least expensive coil. Values were used to calculate the logarithmic ratio of volume over cost. Operator choice among coil sizes can vary the material costs by five-fold in a hypothetical aneurysm. The difference in coil costs as a function of cost per volume of coil can vary tremendously. Using the present pricing algorithms, using the longest available length at a particular helical dimension and system yields improved efficiency. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  14. Resolution of Oculomotor Nerve Palsy Secondary to Posterior Communicating Artery Aneurysms: Comparison of Clipping and Coiling.

    Science.gov (United States)

    McCracken, D Jay; Lovasik, Brendan P; McCracken, Courtney E; Caplan, Justin M; Turan, Nefize; Nogueira, Raul G; Cawley, C Michael; Dion, Jacques E; Tamargo, Rafael J; Barrow, Daniel L; Pradilla, Gustavo

    2015-12-01

    Previous studies have attempted to determine the best treatment for oculomotor nerve palsy (ONP) secondary to posterior communicating artery (PCoA) aneurysms, but have been limited by small sample sizes and limited treatment. To analyze the treatment of ONP secondary to PCoA with both coiling and clipping in ruptured and unruptured aneurysms. Data from 2 large academic centers was retrospectively collected over 22 years, yielding a total of 93 patients with ONP secondary to PCoA aneurysms. These patients were combined with 321 patients from the literature review for large data analyses. Onset symptoms, recovery, and time to resolution were evaluated with respect to treatment and aneurysm rupture status. For all patients presenting with ONP (n = 414) 56.6% of those treated with microsurgical clipping made a full recovery vs 41.5% of those treated with endovascular coil embolization (P = .02). Of patients with a complete ONP (n = 229), full recovery occurred in 47.3% of those treated with clipping but in only 20% of those undergoing coiling (P = .01). For patients presenting with ruptured aneurysms (n = 130), full recovery occurred in 70.9% compared with 49.3% coiled patients (P = .01). Additionally, although patients with full ONP recovery had a median time to treatment of 4 days, those without full ONP recovery had a median time to treatment of 7 days (P = .01). Patients with ONP secondary to PCoA aneurysms treated with clipping showed higher rates of full ONP resolution than patients treated with coil embolization. Larger prospective studies are needed to determine the true potential of recovery associated with each treatment. EUH, Emory University HospitalIQR, interquartile rangeJHU, Johns Hopkins UniversitymRS, modified Rankin ScaleONP, oculomotor nerve palsyPCoA, posterior communicating arterySAH, subarachnoid hemorrhage.

  15. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  16. Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

    International Nuclear Information System (INIS)

    Rabellino, Martin; García-Nielsen, Luis; Zander, Tobias; Baldi, Sebastián; Llorens, Rafael; Maynar, Manuel

    2011-01-01

    Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

  17. Prediction of shape diameter undergoing coil embolization of saccular intracranial aneurysm treatment using a hybrid decision support system

    International Nuclear Information System (INIS)

    Owasirikul, Wiwat; Tantivatana, Jaturon; Gansawat, Duangrat; Auethavekiat, Supatana

    2013-01-01

    The purpose of the study was to design a hybrid decision support system (HDSS) that could simulate the embolized coil selection pattern of the radiologists in aneurysms treatment. As the longest available length of the coils should be used in most cases, therefore only the shape diameter (SD) selection was modeled and varied. Ninety-eight aneurysms successfully treated by a radiologist with coil embolization were divided into two groups (86 for training and 12 randomly selected for validating). Eight aneurysms treated by another radiologist were also used to cross validate the proposed HDSS. The HDSS was developed using the classification and the linear regression methods (LRM). The dome and the width of an aneurysm were used as the system inputs. The system outputs were the SDs of the first three coils indexed according to the insertion order. The HDSS that consisted of Bagging classification and LRM achieved the highest accuracy for all cases. The errors were within 1 mm for the SD selection of the first two coils. For the third coil, the SD selection within 1 mm bound had 80 % accuracy. The experimental results indicated the feasibility of using the HDSS as the guidance for selecting the SDs of the first two coils. The selection of the third coil required more training data for the rarely used SD. Moreover, the cross validation with another radiologist showed the feasibility of using the proposed HDSS as the guidance, however further validation with more data is recommended.

  18. Crossing Y-stent technique with dual open-cell stents for coiling of wide-necked bifurcation aneurysms.

    Science.gov (United States)

    Ko, Jun Kyeung; Han, In Ho; Cho, Won Ho; Choi, Byung Kwan; Cha, Seung Heon; Choi, Chang Hwa; Lee, Sang Weon; Lee, Tae Hong

    2015-05-01

    Double stenting in a Y-configuration is a promising therapeutic option for wide-necked cerebral aneurysms not amenable to reconstruction with a single stent. We retrospectively evaluated the efficacy and safety of the crossing Y-stent technique for coiling of wide-necked bifurcation aneurysms. By collecting clinical and radiological data we evaluated from January 2007 through December 2013, 20 wide-necked bifurcation aneurysms. Twelve unruptured and eight ruptured aneurysms in 20 patients were treated with crossing Y-stent-assisted coiling. Aneurysm size and neck size ranged from 3.2 to 28.2mm (mean 7.5mm) and from 1.9 to 9.1mm (mean 4.5mm). A Y-configuration was established successfully in all 20 patients. All aneurysms were treated with a pair of Neuroform stents. The immediate angiographic results were total occlusion in 17 aneurysms, residual neck in two, and residual sac in one. Peri-operative morbidity was only 5%. Fifteen of 18 surviving patients underwent follow-up conventional angiography (mean, 10.9 months). The result showed stable occlusion in all 15 aneurysms and asymptomatic in-stent occlusion in one branch artery. At the end of the observation period (mean, 33.5 months), all 12 patients without subarachnoid hemorrhage had excellent clinical outcomes (mRS 0), except one (mRS 2). Of eight patients with subarachnoid hemorrhage, four remained symptom free (mRS 0), while the other four had were dependent or dead (mRS score, 3-6). In this report on 20 patients, crossing Y-stent technique for coiling of wide-necked bifurcation aneurysms showed a good technical safety and favorable clinical and angiographic outcome. Copyright © 2015. Published by Elsevier B.V.

  19. Stent-assited coil embolization of vertebrobasilar dissecting aneurysms: Procedual outcomes and factors for recanalization

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jin Pyeong [Dept. of Neurosurgery, Hallym University College of Medicine, Chuncheon (Korea, Republic of); Cho, Young Dae; Cho, Won Sang; Kang, Huin Seung; Hwang, Gyo Hun; Kwon, O Ki; Han, Moon Hee [Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); Rhim, Jong Kook [Dept. of Neurosurgery, Jeju National University College of Medicine, Jeju National University Hospital, Jeju (Korea, Republic of); Park, Jeong Jin [Dept. of Neurology, Konkuk University Hospital, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    Outcomes of stent-assisted coil embolization (SACE) have not been well established in the setting of vertebrobasilar dissecting aneurysms (VBDAs) due to the low percentage of cases that need treatment and the array of available therapeutic options. Herein, we presented clinical and radiographic results of SACE in patients with VBDAs. A total of 47 patients (M:F, 30:17; mean age ± SD, 53.7 ± 12.6 years), with a VBDA who underwent SACE between 2008 and 2014 at two institutions were evaluated retrospectively. Medical records and radiologic data were analyzed to assess the outcome of SACE procedures. Cox proportional hazards regression analysis was conducted to determine the factors that were associated with aneurysmal recanalization after SACE.Stent-assisted coil embolization technically succeeded in all patients. Three cerebellar infarctions occurred on postembolization day 1, week 2, and month 2, but no other procedure-related complications developed. Immediately following SACE, 25 aneurysms (53.2%) showed no contrast filling into the aneurysmal sac. During a mean follow-up of 20.2 months, 37 lesions (78.7%) appeared completely occluded, whereas 10 lesions showed recanalization, 5 of which required additional embolization. Overall recanalization rate was 12.64% per lesion-year, and mean postoperative time to recanalization was 18 months (range, 3–36 months). In multivariable analysis, major branch involvement (hazard ratio [HR]: 7.28; p = 0.013) and the presence of residual sac filling (HR: 8.49, p = 0.044) were identified as statistically significant independent predictors of recanalization. No bleeding was encountered in follow-up monitoring. Stent-assisted coil embolization appears feasible and safe for treatment of VBDAs. Long-term results were acceptable in a majority of patients studied, despite a relatively high rate of incomplete occlusion immediately after SACE. Major branch involvement and coiled aneurysms with residual sac filling may predispose to

  20. Stent-Assisted Coil Embolization of Vertebrobasilar Dissecting Aneurysms: Procedural Outcomes and Factors for Recanalization.

    Science.gov (United States)

    Jeon, Jin Pyeong; Cho, Young Dae; Rhim, Jong Kook; Park, Jeong Jin; Cho, Won-Sang; Kang, Hyun-Seung; Kim, Jeong Eun; Hwang, Gyojun; Kwon, O-Ki; Han, Moon Hee

    2016-01-01

    Outcomes of stent-assisted coil embolization (SACE) have not been well established in the setting of vertebrobasilar dissecting aneurysms (VBDAs) due to the low percentage of cases that need treatment and the array of available therapeutic options. Herein, we presented clinical and radiographic results of SACE in patients with VBDAs. A total of 47 patients (M:F, 30:17; mean age ± SD, 53.7 ± 12.6 years), with a VBDA who underwent SACE between 2008 and 2014 at two institutions were evaluated retrospectively. Medical records and radiologic data were analyzed to assess the outcome of SACE procedures. Cox proportional hazards regression analysis was conducted to determine the factors that were associated with aneurysmal recanalization after SACE. Stent-assisted coil embolization technically succeeded in all patients. Three cerebellar infarctions occurred on postembolization day 1, week 2, and month 2, but no other procedure-related complications developed. Immediately following SACE, 25 aneurysms (53.2%) showed no contrast filling into the aneurysmal sac. During a mean follow-up of 20.2 months, 37 lesions (78.7%) appeared completely occluded, whereas 10 lesions showed recanalization, 5 of which required additional embolization. Overall recanalization rate was 12.64% per lesion-year, and mean postoperative time to recanalization was 18 months (range, 3-36 months). In multivariable analysis, major branch involvement (hazard ratio [HR]: 7.28; p = 0.013) and the presence of residual sac filling (HR: 8.49, p = 0.044) were identified as statistically significant independent predictors of recanalization. No bleeding was encountered in follow-up monitoring. Stent-assisted coil embolization appears feasible and safe for treatment of VBDAs. Long-term results were acceptable in a majority of patients studied, despite a relatively high rate of incomplete occlusion immediately after SACE. Major branch involvement and coiled aneurysms with residual sac filling may predispose to

  1. Stent-assited coil embolization of vertebrobasilar dissecting aneurysms: Procedual outcomes and factors for recanalization

    International Nuclear Information System (INIS)

    Jeon, Jin Pyeong; Cho, Young Dae; Cho, Won Sang; Kang, Huin Seung; Hwang, Gyo Hun; Kwon, O Ki; Han, Moon Hee; Rhim, Jong Kook; Park, Jeong Jin

    2016-01-01

    Outcomes of stent-assisted coil embolization (SACE) have not been well established in the setting of vertebrobasilar dissecting aneurysms (VBDAs) due to the low percentage of cases that need treatment and the array of available therapeutic options. Herein, we presented clinical and radiographic results of SACE in patients with VBDAs. A total of 47 patients (M:F, 30:17; mean age ± SD, 53.7 ± 12.6 years), with a VBDA who underwent SACE between 2008 and 2014 at two institutions were evaluated retrospectively. Medical records and radiologic data were analyzed to assess the outcome of SACE procedures. Cox proportional hazards regression analysis was conducted to determine the factors that were associated with aneurysmal recanalization after SACE.Stent-assisted coil embolization technically succeeded in all patients. Three cerebellar infarctions occurred on postembolization day 1, week 2, and month 2, but no other procedure-related complications developed. Immediately following SACE, 25 aneurysms (53.2%) showed no contrast filling into the aneurysmal sac. During a mean follow-up of 20.2 months, 37 lesions (78.7%) appeared completely occluded, whereas 10 lesions showed recanalization, 5 of which required additional embolization. Overall recanalization rate was 12.64% per lesion-year, and mean postoperative time to recanalization was 18 months (range, 3–36 months). In multivariable analysis, major branch involvement (hazard ratio [HR]: 7.28; p = 0.013) and the presence of residual sac filling (HR: 8.49, p = 0.044) were identified as statistically significant independent predictors of recanalization. No bleeding was encountered in follow-up monitoring. Stent-assisted coil embolization appears feasible and safe for treatment of VBDAs. Long-term results were acceptable in a majority of patients studied, despite a relatively high rate of incomplete occlusion immediately after SACE. Major branch involvement and coiled aneurysms with residual sac filling may predispose to

  2. Y stenting assisted coiling using a new low profile visible intraluminal support device for wide necked basilar tip aneurysms: a technical report.

    Science.gov (United States)

    Conrad, Marcelo D; Brasiliense, Leonardo B C; Richie, Alexa N; Hanel, Ricardo A

    2014-05-01

    Many endovascular techniques have been described in recent years for the management of wide necked aneurysms. The Y stent assisted technique has been generally used for coil embolization of wide necked bifurcation aneurysms. This technique was first described for the treatment of basilar tip aneurysms in combination with several different devices, demonstrating encouraging results. We report the results of the first two cases of wide necked basilar tip aneurysms treated with Y stent assisted coil embolization using a new low profile visible intraluminal stent (LVIS Jr; MicroVention, Tustin, California, USA) delivered through a 0.017 inch microcatheter. We also reviewed the literature comparing other endovascular techniques (coiling alone, stent assisted coiling, and Y stent assisted coiling) for wide necked aneurysms. The LVIS Jr device offers a new option for the treatment of these challenging lesions, with clear advantages over currently available intracranial stents. Larger series and long term results are needed to confirm the applicability and durability of this technique/technology.

  3. The impact of hybrid neurosurgeons on the outcomes of endovascular coiling for unruptured cerebral aneurysms

    Science.gov (United States)

    Bekelis, Kimon; Gottlieb, Dan; Labropoulos, Nicos; Su, Yin; Tzoumakaris, Stavropoula; Jabbour, Pasqual; MacKenzie, Todd A.

    2017-01-01

    Background The impact of combined practices on the outcomes of unruptured cerebral aneurysm coiling remains an issue of debate. We investigated the association of combined open and endovascular expertise with the outcomes of unruptured cerebral aneurysm coiling. Methods We performed a cohort study of 100% of Medicare fee-for-service claims data for elderly patients who underwent endovascular coiling for unruptured cerebral aneurysms from 2007 to 2012. In order to control for confounding we used propensity score conditioning, with mixed effects to account for clustering at the HRR level. Results During the study period, there were 11,716 patients, who underwent endovascular coiling for unruptured cerebral aneurysms, and met the inclusion criteria. Of these, 1,186 (10.1%) underwent treatment by hybrid neurosurgeons, and 10,530 (89.9%) by proceduralists who performed only endovascular coiling. Multivariable regression analysis with propensity score adjustment demonstrated lack of association of combined practice with 1-year postoperative mortality (OR, 0.84; 95% CI, 0.58–1.23), discharge to rehabilitation (OR, 1.0; 95% CI, 0.66–1.51), 30-day readmission rate (OR, 1.07; 95% CI, 0.83–1.38) and length of stay (LOS) (adjusted difference, 0.41; 95% CI, −0.26 to 1.09). Higher procedural volume was independently associated with improved outcomes. Conclusions In a cohort of Medicare patients, we did not demonstrate a difference in mortality, discharge to rehabilitation, readmission rate, and LOS between hybrid neurosurgeons, and proceduralists only performing endovascular coiling. Funding Supported by grants from the National Institute on Aging (PO1- AG19783), the National Institutes of Health Common Fund (U01-AG046830), and the National Center for Advancing Translational Sciences (NCATS) of the NIH (Dartmouth Clinical and Translational Science Institute-UL1TR001086). The funders had no role in the design or execution of the study. PMID:26918479

  4. Retreatment of recanalized aneurysms after Y-stent-assisted coil embolization with double enterprise stents: case report and systematic review of the literature.

    Science.gov (United States)

    Kono, Kenichi; Shintani, Aki; Terada, Tomoaki

    2014-01-01

    It is necessary to consider possibility of recanalization and retreatment after coil embolization for cerebral aneurysms. There is concern that retreatment for recanalized aneurysms after Y-stent-assisted coil embolization may be difficult because of double stents, especially in Y-stents with double closed-cell stents owing to narrowed structures. However, no detailed reports of retreatment after Y-stent have been reported. Between July 2010 and June 2013, we treated four aneurysms with Y-stent-assisted coil embolization using Enterprise closed-cell stents. Recanalization occurred in one case (25%), and retreatment was performed. We easily navigated a microcatheter into the target portions of the aneurysm through the Y-stent and occluded the aneurysm with coils. Additionally, by systematically searching in PubMed, we found 105 cases of Y-stent-assisted coil embolization using Enterprise stents or Neuroform stents with more than 6 months of follow-up. Among them, retreatment was performed in 10 cases (9.5%). There were no significant differences in retreatment rates among different stent combinations (P=0.91; Fisher's exact test). In conclusion, navigation of a microcatheter into the aneurysm through the Y-stent with double Enterprise stents was feasible, and retreatment rates after Y-stent-assisted coiling may not depend on stent combinations.

  5. Stent-assisted coiling of wide-neck bifurcation aneurysms with a branch incorporated in the aneurysm base: long-term follow-up in 49 patients with 53 aneurysms.

    Science.gov (United States)

    Lubicz, Boris; Morais, Ricardo; Bruyère, Pierre-Julien; Ligot, Noémie; Mine, Benjamin

    2017-06-01

    Wide-neck bifurcation intracranial aneurysms (WNBA) with a branch incorporated in the aneurysm base remain difficult to treat by embolization. We aim to report our long-term follow-up of stent-assisted coiling (SAC) in this subgroup of patients. This study was approved by our local ethical committee. A retrospective review of our prospectively maintained database identified all patients treated in our institution by SAC for a WNBA with a branch incorporated in the aneurysm base. Technical issues, immediate, long-term outcomes were evaluated. Between 2007 and 2015, 49 patients with 53 intracranial aneurysms (IAs) (52 unruptured, 1 ruptured) were identified and successfully treated. No morbidity/mortality occurred. The incorporated branch was preserved in all patients but one who was treated during a vasospasm phase. At the first 6-month imaging control, the branch was patent. Immediate occlusion was near-complete in 11/53 aneurysms (20.8%), neck remnant in 20/53 aneurysms (37.7%), and incomplete in 22/53 aneurysms (41.5%). Available imaging follow-up of 47 IAs, ranging from 3 to 84 months (mean 26 months ± 19.6 months), showed 27 progressive thrombosis (57.4%), 17 stable occlusions (36.2%), 1 minor recanalization (2.1%), and 2 significant recanalizations that were retreated (4.3%). The latest imaging control showed 30 near-complete occlusions (63.8%), 13 neck remnants (27.7%), and 4 incomplete occlusions (8.5%). Stent-assisted coiling is safe and effective for the treatment of WNBA with a branch incorporated in the aneurysm base. Despite poor immediate anatomical results, long-term follow-up shows a high rate of progressive thrombosis achieving adequate and stable occlusion in most patients.

  6. The possibility and the countermeasure of the re-rupture within procedure in the embolization of intracranial aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Li Minghua; Gu Binxian; Cheng Yingsheng; Fang Chun; Wang Wu; Xu Tao; Xu Shiding

    2004-01-01

    Objective: To study the possibility and the way to deal with the re-rupture within procedure for rupture aneurysms with Guglielmi detachable coil (GDC) embolization. Methods: When 159 cases with intracranial aneurysms were treated with GDC embolization, the rupture during procedure occurred in 7 cases. Of them, the re-rupture was related to microguidewire in one cases, related to coils in 3 cases, related to microcatheter in 2 cases, and related to over-packing with coils in one case. Results: A continuous packing with GDC with or without microcatheter adjustment, till a total occlusion of aneurysm, was performed in 3 cases with re-rupture related to coils and in 2 cases with re-rupture related to microcatheter. Of them, a complete recovery was acquired in 4 and a monoplegia remained in one case; Both the case with re-rupture related to microguidewire and the case with re-rupture related to over-packing with coils died due to intracerebral over-bleeding. Conclusion: It is unavoidable that the re-rupture occurred during the procedure of GDC embolization of intracranial aneurysms. Its occurrence is in inverse proportion with operator's experience. The proper choice of coils may reduce the occurrence of re-rupture related to procedure. A continuous packing with coils is possible to get a total occlusion without any sequels in re-ruptured aneurysms

  7. Treatment of anterior communicating artery aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Xu Yi; Liu Jianmin; Hong Bo; Zhao Wenyuan; Huang Qinghai; Zhang Xin; Zhang Long

    2003-01-01

    Objective: To summarize the experience on endovascular treatment of anterior communicating artery aneurysms with Guglielmi detachable coils (GDCs) in 262 cases. Methods: All aneurysms were embolized with GDCs. Catheterization at both ICA was used to monitor the patency of parent arteries for patients with well-developed A1 segment of both ACAs. Microcatheter-assisted or microwire-assisted technique was undertaken to keep patency of parent arteries if the aneurysmal neck was involved with A2 segment. Thirty-four cases with multiple aneurysms had been treated successfully only in one session. Results: Complete embolization was achieved in 160 cases, while subtotal in 56 (>90%) and partial in 46 (<90%). Occlusion of parent arteries developed in 10 cases because of over-occlusion, and cerebral infarction was found in 16 cases after the procedure. Three cases with procedure-related thrombosis were revascularized by urokinase profusion. Follow-up angiograms of 3-6 months showed recanalization in 8 cases requiring a second time session. One case of recurrent aneurysm after GDC treatment was cured by surgical clipping. Conclusions: The result of endovascular treatment of anterior communicating artery aneurysms is fruitful and seems to be an alternative method in improving the rate of occlusion and reducing the cerebral infarction

  8. Progressive Occlusion of Small Saccular Aneurysms Incompletely Occluded After Stent-Assisted Coil Embolization : Analysis of Related Factors and Long-Term Outcomes.

    Science.gov (United States)

    Lim, Jeong Wook; Lee, Jeongjun; Cho, Young Dae

    2017-08-08

    Incompletely occluded aneurysms after coil embolization are subject to recanalization but occasionally progress to a totally occluded state. Deployed stents may actually promote thrombosis of coiled aneurysms. We evaluated outcomes of small aneurysms (medium was evident after stent-assisted coiling, assessing factors implicated in subsequent progressive occlusion. Between September 2012 and June 2016, a total of 463 intracranial aneurysms were treated by stent-assisted coil embolization. Of these, 132 small saccular aneurysms displayed saccular filling with contrast medium in the immediate aftermath of coiling. Progressive thrombosis was defined as complete aneurysmal occlusion at the 6‑month follow-up point. Rates of progressive occlusion and factors predisposing to this were analyzed via binary logistic regression. In 101 (76.5%) of the 132 intracranial aneurysms, complete occlusion was observed in follow-up imaging studies at 6 months. Binary logistic regression analysis indicated that progressive occlusion was linked to smaller neck diameter (odds ratio [OR] = 1.533; p = 0.003), hyperlipidemia (OR = 3.329; p = 0.036) and stent type (p = 0.031). The LVIS stent is especially susceptible to progressive thrombosis, more so than Neuroform (OR = 0.098; p = 0.008) or Enterprise (OR = 0.317; p = 0.098) stents. In 57 instances of progressive thrombosis, followed for ≥12 months (mean 25.0 ± 10.7 months), 56 (98.2%) were stable, with minor recanalization noted once (1.8%) and no major recanalization. Aneurysms associated with smaller diameter necks, hyperlipidemic states and LVIS stent deployment may be inclined to possible thrombosis, if occlusion immediately after stent-assisted coil embolization is incomplete. In such instances, excellent long-term durability is anticipated.

  9. Clipping Versus Coiling in the Management of Posterior Communicating Artery Aneurysms with Third Nerve Palsy: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Gaberel, Thomas; Borha, Alin; di Palma, Camille; Emery, Evelyne

    2016-03-01

    To compare surgical clipping with endovascular coiling in terms of recovery from oculomotor nerve palsy (ONP) in the management of posterior communicating artery (PCoA) aneurysms causing third nerve palsy. We conducted a systematic review of the literature and meta-analysis. The meta-analysis included 11 relevant studies involving 384 patients with third nerve palsy caused by PCoA aneurysms at baseline, of whom 257 (67.0%) were treated by clipping and 127 were treated by coiling (33.0%). Pooled odds ratios of the impact of clipping or coiling on complete ONP recovery, lack of ONP recovery, and procedure-related death were calculated. The overall complete ONP recovery rate was 42.5% in the coiling group compared with 83.6% in the clipping group. The increase in complete ONP recovery in the clipping group corresponds to an overall pooled Mantel-Haenszel odds ratio of 4.44 (95% confidence interval = 1.66-11.84). Subgroup analysis revealed a clear benefit of clipping over coiling in patients with ruptured aneurysms, but not in patients with unruptured aneurysms. No procedure-related deaths were reported by any of the 11 studies. Surgical clipping of PCoA aneurysms causing third nerve palsy achieves better ONP recovery than endovascular coiling; this could be particularly true in the case of ruptured aneurysms. In view of the purely observational data, statements about this effect should be made with great caution. A randomized trial would better address the therapeutic dilemma, but pending the results of such a trial, we recommend treating PCoA aneurysms causing ONP with surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Clinical course of a partially thrombosed, symptomatic aneurysm of the basilar artery tip with partial recanalization subsequent to coiling; Verlaufsbeschreibung eines teilthrombosierten symptomatischen Basilariskopfaneurysmas mit teilweiser Rekanalisierung nach Coiling

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, V. [Universitaet des Saarlandes, Abteilung fuer Neuroradiologie, Homburg (Germany); Klinikum Saarbruecken, Institut fuer bildgebende Diagnostik und Interventionen, Saarbruecken (Germany); Axmann, C.; Reith, W. [Universitaet des Saarlandes, Abteilung fuer Neuroradiologie, Homburg (Germany)

    2006-05-15

    A 72-year-old patient was referred to the neuroradiological department for diagnostic angiography. She was suffering from vertigo and double vision. Magnetic resonance imaging performed elsewhere had demonstrated a giant aneurysm of the basilar artery tip 2 cm in diameter. Angiography revealed a large aneurysm with a broad neck that was partially thrombosed, which precluded closure by coiling. Neurosurgical management by clipping also appeared to be unsuitable because of the proximity to the cerebrum. The decision was reached to proceed expectantly by closely monitoring the clinical course. When the aneurysm increased in size in the ensuing weeks, coiling was performed successfully. Angiographic follow-up showed reperfusion of the aneurysm neck and closure was again achieved by repeat coiling. Reperfusion is not a rare complication following coiling and often necessitates renewed intervention. (orig.) [German] Eine 72-jaehrige Patientin wurde in der neuroradiologischen Abteilung zur diagnostischen Angiographie vorgestellt. Sie litt unter Schwindel und Doppelbildern. Eine auswaertige MR-Untersuchung des Gehirns zeigte ein Riesenaneurysma des Basilariskopfes mit einem Durchmesser von 2 cm. Die Angiographie zeigte ein grosses Aneurysma mit breitem Hals, das teilweise thrombosiert war. Dies liess einen Verschluss durch Coiling nicht zu. Eine neurochirurgische Behandlung durch Klippung erschien wegen der Naehe zum Mittelhirn ebenfalls ungeeignet. Man einigte sich auf ein abwartendes Vorgehen durch eine engmaschige Verlaufsbeobachtung. Als das Aneurysma in den folgenden Wochen eine Groessenzunahme zeigte, wurde erfolgreich ein Coiling durchgefuehrt. Eine angiographische Verlaufskontrolle zeigte eine Reperfusion des Aneurysmahalses. Erneut konnte ein Verschluss durch Coiling erzielt werden. Eine Reperfusion ist keine seltene Komplikation nach Coiling, die oft eine erneute Intervention erfordert. (orig.)

  11. Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients.

    Science.gov (United States)

    Sedat, Jacques; Chau, Yves; Gaudart, Jean; Sachet, Marina; Beuil, Stephanie; Lonjon, Michel

    2018-02-01

    Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.

  12. Angle change of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms

    International Nuclear Information System (INIS)

    Cho, W.-S.; Kang, H.-S.; Kim, J.E.; Kwon, O.-K.; Oh, C.W.; Cho, Y.D.; Han, M.H.

    2014-01-01

    Aim: To investigate the angle changes of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms. Materials and methods: The adjacent parent arterial angles before and after stent-assisted coil embolization were measured in 38 patients with aneurysms of the anterior communicating artery (ACoAA) and 41 patients with bifurcation aneurysms of the middle cerebral artery (MCABA). Variables were analysed in relation to the angle changes. Results: Vascular angles of the parent arteries significantly increased by 27.8° (±18.5°) immediately after stent-assisted coil embolization in 79 cases (p < 0.001), with 25.7° (±14.8°) in ACoAA and 29.7° (±21.4°) in MCABA, respectively. In 51 (64.6%) cases with follow-up angiography (mean interval 13.5 ± 4.1 months), vascular angles increased by 27.2° (±17.1°) immediately after treatment and further increased by 20.7° (±14.3°) at the last follow-up (all p < 0.001). More acute pre-stent angles of the parent arteries correlated with greater post-stent angle changes (p = 0.006). Younger age tended to be inversely related to post-stent angle changes (p = 0.091). Conclusion: Stent placement during coil embolization induced significant changes in the aneurysm–parent artery relationship. Further study is needed to elicit the association between angle change of the parent arteries and aneurysmal stability after coil embolization

  13. Feasibility of magnetic resonance angiography (MRA) follow-up as the primary imaging modality after coiling of intracranial aneurysms

    International Nuclear Information System (INIS)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Dijk, J. Marc C. van; Mooij, Jan Jakob A.; Groen, Rob J. M.; Westerlaan, Henriette E.; Eshghi, Omid S.

    2010-01-01

    Background: Digital subtraction angiography (DSA) is still regarded as the gold standard for detecting residual flow in treated aneurysms. Recent reports have also shown excellent results from magnetic resonance angiography (MRA) imaging. This is an important observation, since DSA is associated with a risk of medical complications, is time consuming, and is more expensive. Purpose: To determine whether MRA could replace conventional DSA and serve as the primary postinterventional imaging modality in patients with coiled intracranial aneurysms. Material and Methods: We studied a prospectively enrolled cohort of 190 patients treated endovascularly for a first-ruptured and/or unruptured intracranial aneurysm between January 2004 and December 2008. The imaging protocol included a 1.5T time-of-flight (TOF) MRA and a DSA at 3 months (on the same day) and, depending on comparability, a 1.5T TOF-MRA or DSA 1 year after treatment. All images were evaluated by a multidisciplinary panel. Results: In 141/190 patients, both an MRA and DSA were performed after 3-month follow-up. In 2/141 patients (1.4%), (small) neck remnants gave false-negative MRA results. In one patient (0.7%), this led to additional neurosurgical clipping of the aneurysm. In 25/141 patients, future follow-up (>3 months) consisted of DSA because of various reasons. In 24/25 of these patients, primary MRA images alone would invariably have led to additional DSA imaging. Conclusion: The present study shows that 1.5T TOF-MRA is a feasible primary follow-up modality after coiling of intracranial aneurysms. Given our data, we now suggest that, in every patient with a coiled intracranial aneurysm, the first follow-up, 3 months after coiling, should be an MRA study. Only when this MRA is inconclusive (e.g., because of coil artifacts), or in the case of suspicion of recanalization, should DSA be performed additionally

  14. Coil Embolization of Pancreaticoduodenal Artery Aneurysms Associated with Celiac Artery Stenosis: Report of Three Cases

    International Nuclear Information System (INIS)

    Ikeda, Osamu; Tamura, Yoshitaka; Nakasone, Yutaka; Kawanaka, Kohichi; Yamashita, Yasuyuki

    2007-01-01

    Aneurysms of the pancreaticoduodenal artery are rare. Degeneration of pancreaticoduodenal arcade vessels due to these aneurysms is associated with celiac artery stenosis or occlusion. Untreated lesions enlarge progressively and may rupture spontaneously. As the location of aneurysms of pancreaticoduodenal arcade vessels renders their surgical extirpation a challenge, we examined whether endovascular techniques offer a treatment alternative. We report on 3 patients with aneurysms of the pancreaticoduodenal arcade vessels and concomitant celiac artery stenosis/occlusion due to compression by the median arcuate ligament or chronic pancreatitis. All patients were treated by percutaneous coil embolization of the aneurysm. The aneurysmal sac was successfully excluded and the native circulation was preserved. Endovascular surgery can be used to treat these aneurysms safely and permits retention of the native circulation

  15. Coiling and clipping of middle cerebral artery aneurysms: a systematic review on clinical and imaging outcome

    NARCIS (Netherlands)

    Zijlstra, Ijsbrand A.; Verbaan, Dagmar; Majoie, Charles B.; Vandertop, Peter; van den Berg, Rene

    2016-01-01

    There is an ongoing debate on the preferred treatment of middle cerebral artery (MCA) aneurysms. The purpose of this study was to assess the clinical and imaging outcomes comparing conventional coiling and clipping of unruptured and ruptured MCA aneurysms. We searched the electronic databases

  16. Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature.

    Science.gov (United States)

    King, Brent; Vaziri, Sasha; Singla, Amit; Fargen, Kyle M; Mocco, J

    2015-12-01

    The most widely used intracranial stents for stent-assisted coiling are Neuroform (NEU) and Enterprise stents (ENT). This study compares published outcomes between the ENT and NEU coil-assist systems and comments on the published safety and efficacy of stent-assisted coiling in general. A literature search was performed through PubMed for all published series of ENT or NEU stent-assisted coiling of cerebral aneurysms from 2004 to 2014. All studies including 10 or more published cases of stent-assisted coiling with ENT or NEU were included. 47 studies met the inclusion criteria, containing 4238 aneurysms in 4039 patients. 2111 aneurysms were treated with NEU and 2127 were treated with ENT. Mean follow-up was 14.1 months. Overall, thromboembolic events occurred in 6.4% of aneurysms, intracranial hemorrhage (ICH) in 2.6%, permanent morbidity in 3.9%, and mortality in 2.3%. Initial and final 100% angiographic occlusion was seen in 53% and 69% of patients, respectively. Deployment failures (pstent-assisted coiling devices to date, containing over 4200 aneurysms in more than 4000 patients. Comparative analyses demonstrate that both devices are reported to be safe and effective with comparable permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, Jacques; Chau, Yves; Mondot, Lydiane [CHU Nice, Unite de Neurointerventionnelle, Hopital St. Roch, Nice (France); Vargas, Julian; Szapiro, Jacek; Lonjon, Michel [CH Bastia, Service de Neurochirurgie, Bastia (France)

    2009-06-15

    Coiling associated with placement of self-expandable intracranial stents has amplified the treatment of intracranial wide-necked aneurysms, but the durability of this treatment and the existence of delayed recurrence are not yet well known. The purpose of this report is to present our experience with the Neuroform Stent associated with coiling and to evaluate complications, effectiveness, and long-term results of this technique. A retrospective study of 42 patients with wide-necked cerebral aneurysms treated with the Neuroform Stent was performed. Mean aneurysm size was 11.3 mm. Mean neck size was 5.33 mm. All patients were treated with coiling and stenting. Clinical and angiographic follow-up was available in 38 patients (90.5%). The overall follow-up time ranged from 6 months to 5 years (mean, 42 months), but most of the patients (92%) had a follow-up period superior to 1 year. Successful deployment of 41 stents (97%) was obtained. Permanent procedural morbidity was observed in only one patient (2.4%). Long-term complete aneurysmal occlusion was obtained in 27 patients (71%). Aneurysmal regrowth was observed in four patients (9.5%) on the first control angiogram. After the first control angiogram, no delayed recanalization or regrowth was observed. During the follow-up period, there were no hemorrhagic events, no delayed thrombosis, and no stent displacement. Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year. (orig.)

  18. GDC 360 for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D coils in 38 patients

    International Nuclear Information System (INIS)

    Taschner, Christian A.; Thines, Laurent; Lejeune, Jean-Paul; El-Mahdy, Mohamed; Rachdi, Henda; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2009-01-01

    The purpose of this study was to determine whether coil embolisation with a new complex-shaped Guglielmi Detachable Coil (GDC 360 ; Boston Scientific Neurovascular, Fremont, CA, USA) has any effect on the stability of aneurysm occlusion. Fifty-one consecutive patients with intracranial aneurysms treated with GDC 360 were included. Angiographic results and adverse neurological events during the follow-up period were recorded. For 38 patients treated with GDC 360 with available follow-up data, a corresponding patient treated with GDC 3D was identified from our database. Matches were sought for rupture status, location, aneurysmal size, and neck size. The angiographic outcome of these matched controls at 6 months was compared to aneurysms treated with GDC 360 . Initial angiographic controls for 38 patients treated with GDC 360 showed complete occlusion in 32 aneurysms, and a neck remnant in six. At 6-month follow-up, complete occlusion was found in 29, a neck remnant in eight, and a residual aneurysm in one. One patient treated with GDC 360 needed retreatment for a major recanalisation. In 38 matched patients treated with GDC 3D, initial angiographic controls found complete aneurysmal occlusion in 30 aneurysms and a residual neck in 8. At 6-month follow-up, 24 aneurysms were completely occluded, ten showed a neck remnant, and residual aneurysms were seen in four. Four patients, treated with GDC 3D, were retreated for major aneurysm recanalisations. Our data suggests that endovascular coil embolisation with GDC 360 might improve long-term stability of coiled aneurysms when compared to GDC 3D. (orig.)

  19. Development of a static bioactive stent prototype and dynamic aneurysm-on-a-chip(TM) model for the treatment of aneurysms

    Science.gov (United States)

    Reece, Lisa M.

    Aneurysms are pockets of blood that collect outside blood vessel walls forming dilatations and leaving arterial walls very prone to rupture. Current treatments include: (1) clipping, and (2) coil embolization, including stent-assisted coiling. While these procedures can be effective, it would be advantageous to design a biologically active stent, modified with magnetic stent coatings, allowing cells to be manipulated to heal the arterial lining. Further, velocity, pressure, and wall shear stresses aid in the disease development of aneurysmal growth, but the shear force mechanisms effecting wound closure is elusive. Due to these factors, there is a definite need to cultivate a new stent device that will aid in healing an aneurysm in situ. To this end, a static bioactive stent device was synthesized. Additionally, to study aneurysm pathogenesis, a lab-on-a-chip device (a dynamic stent device) is the key to discovering the underlying mechanisms of these lesions. A first step to the reality of a true bioactive stent involves the study of cells that can be tested against the biomaterials that constitute the stent itself. The second step is to test particles/cells in a microfluidic environment. Therefore, biocompatability data was collected against PDMS, bacterial nanocellulose (BNC), and magnetic bacterial nanocellulose (MBNC). Preliminary static bioactive stents were synthesized whereby BNC was grown to cover standard nitinol stents. In an offshoot of the original research, a two-dimensional microfluidic model, the Aneurysm-on-a-ChipTM (AOC), was the logical answer to study particle flow within an aneurysm "sac" - this was the dynamic bioactive stent device. The AOC apparatus can track particles/cells when it is coupled to a particle image velocimetry software (PIV) package. The AOC fluid flow was visualized using standard microscopy techniques with commercial microparticles/cells. Movies were taken during fluid flow experiments and PIV was utilized to monitor.

  20. Is digital substraction angiography still needed for the follow-up of intracranial aneurysms treated by embolisation with detachable coils?

    International Nuclear Information System (INIS)

    Lubicz, Boris; Neugroschl, Carine; Collignon, Laurent; Francois, Olivier; Baleriaux, Danielle

    2008-01-01

    Follow-up of intracranial aneurysms treated by embolisation with detachable coils is mandatory to detect a possible recanalisation. The aim of this study was to compare contrast-enhanced magnetic resonance angiography (CE-MRA) with digital substraction angiography (DSA) used to detect aneurysm recanalisation to determine if DSA is still needed during follow-up. From May 2006 to May 2007, 55 patients with 67 aneurysms were treated by endosaccular coiling with (n=9) or without (n=58) an adjunctive stent. Follow-up imaging protocol included MRA at 6 and 12 months and a DSA at 12 months or earlier if a major recanalisation was identified on the 6-month MRA. Two neuroradiologists independently reviewed MRA images (readers 1 and 2) and two other reviewed DSA images. Follow-up DSA showed stability of the aneurysm occlusion in 52 cases, recanalisation in 14 cases, and further thrombosis in one. On CE-MRA, both readers identified all recanalisations but one (sensitivity of 93%) as they missed a major recanalisation in a 2-mm ruptured aneurysm. There were two false-positive evaluations by reader 1 and three for reader 2. Mean specificity of CE-MRA to detect aneurysm recanalisation was 95.5%. CE-MRA is accurate to detect aneurysm recanalisation after embolisation with detachable coils. CE-MRA may be proposed as first-intention imaging technique for their follow-up. However, its sensitivity and specificity remain inferior to that of DSA and major recurrences may be missed in very small aneurysms. Therefore, a single DSA remains mandatory during the imaging follow-up. (orig.)

  1. Treatment of ruptured intracranial aneurysms: implications of the ISAT on clipping versus coiling

    International Nuclear Information System (INIS)

    Berg, R. van den; Rinkel, G.J.E.; Vandertop, W.P.

    2003-01-01

    Patients with a ruptured intracranial aneurysm should be treated as soon as possible after the haemorrhage to prevent rebleeding and to allow vigorous treatment of ischemic events in case of vasospasm. The choice of treatment, endovascular or surgical, should be based on the angio-architectural aspects of the aneurysm. 3D rotational subtraction angiography will more clearly show the aneurysm morphology and will therefore help in the decision-making process. If an aneurysm is suitable for endovascular treatment ('coiling'), this should be the treatment of first choice, as has been clarified in the ISAT study. Location of the aneurysm only influences the treatment decision in aneurysms located at the basilar artery bifurcation. These aneurysms are preferably treated by endovascular means. The long-term results of endovascular and surgical treatment are still the subject of debate. For both treatment modalities, re-growth of the treated aneurysm has been described, but solid comparative data is missing. In analogy with the ISAT, referral of patients with a ruptured intracranial aneurysm should be performed as soon as possible after the haemorrhage. Preferably, this should be a hospital where neurosurgeons, interventional neuroradiologists, as well as neurologists (with expertise on medical treatment of patients with a subarachnoid haemorrhage) collaborate

  2. Nursing assistance for spring coil occlusion for the treatment of intracranial giant internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Ma Yugang; Mao Yanjun; Yuan Yili; Hu Yaqin; Liu Jing; Xi Juan

    2010-01-01

    Objective: To discuss the importance of balloon occlusion test before interventional treatment of the intracranial giant internal carotid artery aneurysms and to sum up the nursing experience in assisting the procedure. Methods: Proper perioperative nursing measures were carried out for 12 patients, who suffered from intracranial giant internal carotid artery aneurysm and underwent spring coil occlusion treatment. Nursing measures included mental care, observation of the vital signs, prevention of the complications, etc. Results: Neither death nor exacerbation of the condition occurred in all the 12 patients. The patients were discharged from the hospital with a mean hospitalization of nine days. During a follow-up period ranged from 4 months to one year, seven patients had no disagreeable feeling, one patient complained of discomfort but no abnormality was found on follow-up DSA, and disappearance of the aneurysm was observed in 4 patients. Conclusion: The monitoring of the vital signs, the prevention of the complications and the standard nursing care are the key points for ensuring a successful operation in treating intracranial giant internal carotid artery aneurysms with spring coil occlusion. (authors)

  3. Long-term MRA follow-up after coiling of intracranial aneurysms: impact on mood and anxiety

    International Nuclear Information System (INIS)

    Ferns, Sandra P.; Nieuwkerk, Pythia T.; Majoie, Charles B.L.M.; Rooij, Willem Jan J. van; Rinkel, Gabriel J.E.

    2011-01-01

    Magnetic resonance angiography (MRA) screening for recurrence of a coiled intracranial aneurysm and formation of new aneurysms long-term after coiling may induce anxiety and depression. In coiled patients, we evaluated effects on mood and level of anxiety from long-term follow-up MRA in comparison to general population norms. Of 162 patients participating in a long-term (>4.5 years) MRA follow-up after coiling, 120 completed the EQ-5D questionnaire, a visual analog health scale and a self-developed screening related questionnaire at the time of MRA. Three months later, the same questionnaires were completed by 100 of these 120 patients. Results were compared to general population norms adjusted for gender and age. Any problem with anxiety or depression was reported in 56 of 120 patients (47%; 95%CI38 56%) at baseline and 42 of 100 patients (42%; 95%CI32 52%) at 3 months, equally for screen-positives and -negatives. Compared to the reference population, participants scored 38% (95%CI9 67%) and 27% (95%CI4 50%) more often any problem with anxiety or depression. Three months after screening, 21% (20 of 92) of screen-negatives and 13% (one of eight) of screen-positives reported to be less afraid of subarachnoid hemorrhage (SAH) compared to before screening. One of eight screen-positives reported increased fear of SAH. Patients with coiled intracranial aneurysms participating in long-term MRA screening reported significantly more often to be anxious or depressed than a reference group. Screening did not significantly increase anxiety or depression temporarily. However, subjectively, patients did report an increase in anxiety caused by screening, which decreased after 3 months. (orig.)

  4. Long-term MRA follow-up after coiling of intracranial aneurysms: impact on mood and anxiety

    Energy Technology Data Exchange (ETDEWEB)

    Ferns, Sandra P.; Nieuwkerk, Pythia T.; Majoie, Charles B.L.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Rooij, Willem Jan J. van [St. Elisabeth Ziekenhuis, Department of Radiology, Tilburg (Netherlands); Rinkel, Gabriel J.E. [University Medical Center, Department of Neurology, Rudolf Magnus Institute of Neuroscience, Utrecht (Netherlands)

    2011-05-15

    Magnetic resonance angiography (MRA) screening for recurrence of a coiled intracranial aneurysm and formation of new aneurysms long-term after coiling may induce anxiety and depression. In coiled patients, we evaluated effects on mood and level of anxiety from long-term follow-up MRA in comparison to general population norms. Of 162 patients participating in a long-term (>4.5 years) MRA follow-up after coiling, 120 completed the EQ-5D questionnaire, a visual analog health scale and a self-developed screening related questionnaire at the time of MRA. Three months later, the same questionnaires were completed by 100 of these 120 patients. Results were compared to general population norms adjusted for gender and age. Any problem with anxiety or depression was reported in 56 of 120 patients (47%; 95%CI38<->56%) at baseline and 42 of 100 patients (42%; 95%CI32<->52%) at 3 months, equally for screen-positives and -negatives. Compared to the reference population, participants scored 38% (95%CI9<->67%) and 27% (95%CI4<->50%) more often any problem with anxiety or depression. Three months after screening, 21% (20 of 92) of screen-negatives and 13% (one of eight) of screen-positives reported to be less afraid of subarachnoid hemorrhage (SAH) compared to before screening. One of eight screen-positives reported increased fear of SAH. Patients with coiled intracranial aneurysms participating in long-term MRA screening reported significantly more often to be anxious or depressed than a reference group. Screening did not significantly increase anxiety or depression temporarily. However, subjectively, patients did report an increase in anxiety caused by screening, which decreased after 3 months. (orig.)

  5. Long-term recurrent subarachnoid hemorrhage after adequate coiling versus clipping of ruptured intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Sprengers, Marieke E.; van Rooij, Willem Jan; Sluzewski, Menno; Majoie, Charles B. L. M.; Wermer, Marieke J. H.; Rinkel, Gabriel J. E.

    2009-01-01

    BACKGROUND AND PURPOSE: Coiling is increasingly used as treatment for intracranial aneurysms. Despite its favorable short-term outcome, concerns exist about long-term reopening and inherent risk of recurrent subarachnoid hemorrhage (SAH). We hypothesized a higher risk for recurrent SAH after

  6. Long-Term Recurrent Subarachnoid Hemorrhage After Adequate Coiling Versus Clipping of Ruptured Intracranial Aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Sprengers, Marieke E.; van Rooij, Willem Jan; Sluzewski, Menno; Majoie, Charles B. L. M.; Wermer, Marieke J. H.; Rinkel, Gabriel J. E.

    Background and Purpose-Coiling is increasingly used as treatment for intracranial aneurysms. Despite its favorable short-term outcome, concerns exist about long-term reopening and inherent risk of recurrent subarachnoid hemorrhage (SAH). We hypothesized a higher risk for recurrent SAH after adequate

  7. Rigid 3D-3D registration of TOF MRA integrating vessel segmentation for quantification of recurrence volumes after coiling cerebral aneurysm

    International Nuclear Information System (INIS)

    Saering, Dennis; Forkert, Nils Daniel; Fiehler, Jens; Ries, Thorsten

    2012-01-01

    A fast and reproducible quantification of the recurrence volume of coiled aneurysms is required to enable a more timely evaluation of new coils. This paper presents two registration schemes for the semi-automatic quantification of aneurysm recurrence volumes based on baseline and follow-up 3D MRA TOF datasets. The quantification of shape changes requires a previous definition of corresponding structures in both datasets. For this, two different rigid registration methods have been developed and evaluated. Besides a state-of-the-art rigid registration method, a second approach integrating vessel segmentations is presented. After registration, the aneurysm recurrence volume can be calculated based on the difference image. The computed volumes were compared to manually extracted volumes. An evaluation based on 20 TOF MRA datasets (baseline and follow-up) of ten patients showed that both registration schemes are generally capable of providing sufficient registration results. Regarding the quantification of aneurysm recurrence volumes, the results suggest that the second segmentation-based registration method yields better results, while a reduction of the computation and interaction time is achieved at the same time. The proposed registration scheme incorporating vessel segmentation enables an improved quantification of recurrence volumes of coiled aneurysms with reduced computation and interaction time. (orig.)

  8. Coil embolization of a false aneurysm with aorto-cutaneous fistula after prosthetic graft replacement of the ascending aorta

    International Nuclear Information System (INIS)

    Miguel, Bruno; Camilleri, Lionel; Gabrillargues, Jean; Macheda, Bruno; Kubota, Hiroshi; Ravel, Anne; Riberolles, Charles de; Boyer, Louis

    2000-01-01

    Aim: To report palliative embolization of a false aneurysm over the distal suture line of an ascending aorta graft replacement. Material and Method: A 78-year-old male patient was admitted for increasing bleeding of a chronic Manubrium ulceration, 20 months after coronary artery bypass complicated by perioperative ascending aorta dissection requiring prosthetic graft replacement. One month later, he underwent epiploplasty for a mediastinitis followed by long-term antibiotic therapy. Five months later, he presented with a Manubrium ulceration of the sternotomy. Spiral computerized tomography (CT) and aortography revealed a 20 mm anterior peri-prosthetic false aneurysm with a wide neck. Advanced age, active mediastinitis and patient's objection led us to perform percutaneous occlusion according to the Moret remodeling technique while protecting the coils release with balloon catheter inflation. Results: No post-operative complication was observed and at 1-year follow-up the patient was doing well with no recurrent bleeding. Magnetic resonance imaging (MRI) and spiral CT controls confirmed coils stability without any internal flow. Conclusion: Percutaneous coils embolization of a large false aneurysm in the ascending aorta can be a palliative treatment in a surgically unsuited patient

  9. Large Renal Artery Aneurysm Treated with Guglielmi Detachable Coils: Procedural and 4-Year Follow-up Results

    International Nuclear Information System (INIS)

    Damascelli, Bruno; Bartorelli, Antonio L.; Ticha, Vladimira; Trabattoni, Daniela; Lanocita, Rodolfo

    2008-01-01

    A large aneurysm of the left renal artery was found incidentally during abdominal ultrasound in a 39-year-old woman with no medical or family history of cardiovascular disease. Vascular pathology with a dysplastic appearance was confirmed by magnetic resonance angiography and the patient was offered transcatheter embolization. Since the position and size of the neck of the aneurysm could not be determined at angiography, detachable platinum coils were used for occlusion. The procedure was performed without complications. During a 4-year follow-up no alterations of renal function, recanalization of the aneurysm, or perfusion defects in the rest of the left renal circulation were noted.

  10. A Less Invasive Strategy for Ruptured Cerebral Aneurysms with Intracerebral Hematomas: Endovascular Coil Embolization Followed by Stereotactic Aspiration of Hematomas Using Urokinase

    Science.gov (United States)

    Kim, Sang Heum; Kong, Min Ho

    2017-01-01

    Objective Aneurysm clipping and simultaneous hematoma evacuation through open craniotomy is traditionally recommended for ruptured cerebral aneurysms accompanied by intracerebral or intrasylvian hemorrhages. We report our experience of adapting a less invasive treatment strategy in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms, where the associated ruptured cerebral aneurysms were managed by endovascular coil embolization, followed by stereotactic aspiration of hematomas (SRH) using urokinase. Materials and Methods We retrospectively analyzed 112 patients with ruptured cerebral aneurysms. There were accompanying intracerebral or intrasylvian hemorrhages in 36 patients (32.1%). The most common site for these ruptured aneurysms was the middle cerebral artery (MCA) (n = 15; 41.6%). Endovascular coil embolization followed by SRH using urokinase was performed in 9 patients (25%). Results In these 9 patients, the most common site of aneurysms was the MCA (n = 3; 33.4%); the hematoma volume ranged from 19.24 to 61.68 mL. Four patients who were World Federation of Neurological Surgeons (WFNS) grade-IV on admission, achieved favorable outcomes (Glasgow Outcome Score [GOS] 4 or 5) at 6-months postoperatively. In the five patients who were WFNS grade-V on admission, one achieved a favorable outcome, whereas 4 achieved GOS scores of 2 or 3, 6-months postoperatively. There was no mortality. Conclusion If immediate hematoma evacuation is not mandated by clinical or radiological signs of brain herniation, a less invasive strategy, such as endovascular coil embolization followed by SRH using urokinase, may be a good alternative in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms. PMID:29152466

  11. Level of headaches after surgical aneurysm clipping decreases significantly faster compared to endovascular coiled patients

    Directory of Open Access Journals (Sweden)

    Athanasios K. Petridis

    2017-04-01

    Full Text Available In incidental aneurysms, endovascular treatment can lead to post-procedural headaches. We studied the difference of surgical clipping vs. endovascular coiling in concern to post-procedural headaches in patients with ruptured aneurysms. Sixtyseven patients with aneurysmal subarachnoidal haemorrhage were treated in our department from September 1st 2015 - September 1st 2016. 43 Patients were included in the study and the rest was excluded because of late recovery or highgrade subarachnoid bleedings. Twenty-two were surgical treated and twenty-one were interventionally treated. We compared the post-procedural headaches at the time points of 24 h, 21 days, and 3 months after treatment using the visual analog scale (VAS for pain. After surgical clipping the headache score decreased for 8.8 points in the VAS, whereas the endovascular treated population showed a decrease of headaches of 3.3 points. This difference was highly statistical significant and remained significant even after 3 weeks where the pain score for the surgically treated patients was 0.68 and for the endovascular treated 1.8. After 3 months the pain was less than 1 for both groups with surgically treated patients scoring 0.1 and endovascular treated patients 0.9 (not significant. Clipping is relieving the headaches of patients with aneurysm rupture faster and more effective than endovascular coiling. This effect stays significant for at least 3 weeks and plays a crucial role in stress relieve during the acute and subacute ICU care of such patients.

  12. The Medusa Multi-Coil Versus Alternative Vascular Plugs for Iliac Artery Aneurysm Embolization (MVP-EMBO) Study.

    Science.gov (United States)

    George, Jon C; Varghese, Vincent; Kovach, Richard

    2016-01-01

    Transcatheter embolization has evolved from the use of autologous clot as the embolic agent, to stainless-steel coils, to braided-nitinol vascular plugs. However, there are disadvantages to platinum and metal coils, including procedural time, radiation exposure, mass effect, risk of distal embolization, recanalization, imaging artifacts, and cost. Therefore, a large vessel-occluding device is needed to mitigate these current disadvantages. The Medusa Multi-Coil (MMC; EndoShape, Inc) is a Food and Drug Administration (FDA)-approved embolization device constructed primarily of radioopaque coils with synthetic fibers to promote thrombogenicity, and a unique delivery platform with both proximal and distal attachment to assist with precise placement. We report our experience with the endovascular treatment of internal iliac artery aneurysms using platinum coils vs MMCs.

  13. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography.

    Science.gov (United States)

    Beller, Ebba; Klopp, David; Göttler, Jens; Kaesmacher, Johannes; Zimmer, Claus; Kirschke, Jan S; Prothmann, Sascha

    2016-01-01

    Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1), respectively, more remote from the aneurysm neck (δ2) were graphically determined in 2D angiography projections. Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM) of α = 119° (±6.5°) pretreatment to 130° (±6.6°) posttreatment (P ≤ .001), δ1 = 129° (±6.4°) to 139° (±6.1°), (P ≤ .001) and δ2 = 115° (±8.4°) to 126° (±7.5°), (P ≤ .01). Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05). The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01). Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05). Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome.

  14. Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography.

    Directory of Open Access Journals (Sweden)

    Ebba Beller

    Full Text Available Stent-assisted coil embolization (SACE plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms.31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and afferent vessel, and angle between afferent and efferent vessel close to (δ1, respectively, more remote from the aneurysm neck (δ2 were graphically determined in 2D angiography projections.Stent assisted coiling resulted in a significant increase of all three angles from a mean value (±SEM of α = 119° (±6.5° pretreatment to 130° (±6.6° posttreatment (P ≤ .001, δ1 = 129° (±6.4° to 139° (±6.1°, (P ≤ .001 and δ2 = 115° (±8.4° to 126° (±7.5°, (P ≤ .01. Angular change of δ1 in AcomA aneurysms was significant greater compared to sidewall aneurysms (26°±4.9° versus 8°± 2.3°, P ≤ .05. The initial angle of δ1 and δ2 revealed a significantly inverse relationship to the angle increase (δ1: r = -0.41, P ≤ .05 and δ2: r = -0.47, P ≤ .01. Moreover, angle δ1 was significantly higher in unruptured compared to ruptured aneurysms (135°±7.1° versus 103°±10.8°, P ≤ .05.Stent deployment modulates the geometry of the aneurysm-vessel complex, which may lead to favorable hemodynamic changes more similar to unruptured than to ruptured aneurysms. Our findings also suggest that the more acute-angled aneurysm-vessel anatomy, the larger the angular change. Further studies are needed to investigate whether these changes improve the clinical outcome.

  15. Stent assisted coil embolization of a dissecting aneurysm of the vertebral artery: a case involving a patient with hypoplasia of the contralateral vertebral artery

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Jeong, Hae Woong; Cho, Jae Kwoeng; Park, Jeong Hoon; Koo, Yong Woon; Baik, Seung Kug

    2002-01-01

    A dissecting aneurysm of the vertebral artery may be treated conservatively, surgically, or using an endovascular approach. Proximal clipping, wrapping or trapping are surgical treatment methods, and endovascular treatment with coils and balloons is performed where a dissecting aneurysm is located near the midline or the appropriate surgical manipulation is difficult. As the contralateral vertebral artery of this patient was hypoplastic, the stent-assisted coil embolization technique was employed to preserve the ipsilateral vertebral artery. We describe a clinical case of dissecting aneurysm of the vertebral artery occurring in a patient in whom a hypoplastic contralateral vertebral artery was successfully treated

  16. Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms

    International Nuclear Information System (INIS)

    Lubicz, Boris; Bandeira, Alexandra; Baleriaux, Danielle; Bruneau, Michael; Witte, Olivier de; Dewindt, Aloys

    2009-01-01

    Stent-assisted coiling (SAC) is an alternative to surgical clipping for the treatment of wide-necked intracranial aneurysms (IA). However, little information is available concerning the long-term results of this treatment. The aim of this study was to report the long-term clinical and anatomical findings in 32 patients with 34 wide-necked IA treated by SAC. A retrospective review of our prospectively maintained database identified all patients followed up for wide-necked IA treated by SAC. The clinical charts, procedural data, and angiographic results were reviewed. Thirty-two patients with 34 IA were identified including 25 asymptomatic patients, four with cranial nerve palsies, two with a subarachnoid hemorrhage, and one with transient ischemic attacks. Mean aneurysm size was 10.2 mm (range 3.5 to 26 mm). Embolization was successful in all patients and no procedure-related neurological morbidity or mortality was observed. Immediate anatomical results included nine complete occlusions (26.5%), two neck remnants (6%), and 23 incomplete occlusions (67.5%). Mean imaging follow-up of 20 months showed 18 further thrombosis (53%) and 16 stable results (47%). Finally, 27 aneurysms were completely occluded (79%), three had a neck remnant (9%), and four were incompletely occluded (12%). Asymptomatic and nonsignificant in-stent stenosis occurred in seven patients (22%). SAC is safe and effective for the treatment of wide-necked IA. Despite unsatisfying immediate aneurysm occlusion, the adjunctive effect of the stent is stabilizing or significantly improving long-term anatomical results. (orig.)

  17. Aneurysm Recurrence Volumetry Is More Sensitive than Visual Evaluation of Aneurysm Recurrences.

    Science.gov (United States)

    Schönfeld, M H; Schlotfeldt, V; Forkert, N D; Goebell, E; Groth, M; Vettorazzi, E; Cho, Y D; Han, M H; Kang, H-S; Fiehler, J

    2016-03-01

    Considerable inter-observer variability in the visual assessment of aneurysm recurrences limits its use as an outcome parameter evaluating new coil generations. The purpose of this study was to compare visual assessment of aneurysm recurrences and aneurysm recurrence volumetry with an example dataset of HydroSoft coils (HSC) versus bare platinum coils (BPC). For this retrospective study, 3-dimensional time-of-flight magnetic resonance angiography datasets acquired 6 and 12 months after endovascular therapy using BPC only or mainly HSC were analyzed. Aneurysm recurrence volumes were visually rated by two observersas well as quantified by subtraction of the datasets after intensity-based rigid registration. A total of 297 aneurysms were analyzed (BPC: 169, HSC: 128). Recurrences were detected by aneurysm recurrence volumetry in 9 of 128 (7.0 %) treated with HSC and in 24 of 169 (14.2 %) treated with BPC (odds ratio: 2.39, 95 % confidence interval: 1.05-5.48; P = 0.039). Aneurysm recurrence volumetry revealed an excellent correlation between observers (Cronbach's alpha = 0.93). In contrast, no significant difference in aneurysm recurrence was found for visual assessment (3.9 % in HSC cases and 4.7 % in BPC cases). Recurrences were observed in aneurysms smaller than the sample median in 10 of 33 (30.3 %) by aneurysm recurrence volumetry and in 1 of 13 (7.7 %) by visual assessment. Aneurysm recurrences were detected more frequently by aneurysm recurrence volumetry when compared with visual assessment. By using aneurysm recurrence volumetry, differences between treatment groups were detected with higher sensitivity and inter-observer validity probably because of the higher detection rate of recurrences in small aneurysms.

  18. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    Science.gov (United States)

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  19. Microcatheter Shaping for Intracranial Aneurysm Coiling Using the 3-Dimensional Printing Rapid Prototyping Technology: Preliminary Result in the First 10 Consecutive Cases.

    Science.gov (United States)

    Namba, Katsunari; Higaki, Ayuho; Kaneko, Naoki; Mashiko, Toshihiro; Nemoto, Shigeru; Watanabe, Eiju

    2015-07-01

    An optimal microcatheter is necessary for successful coiling of an intracranial aneurysm. The optimal shape may be predetermined before the endovascular surgery via the use of a 3-dimensional (3D) printing rapid prototyping technology. We report a preliminary series of intracranial aneurysms treated with a microcatheter shape determined by the patient's anatomy and configuration of the aneurysm, which was fabricated with a 3D printer aneurysm model. A solid aneurysm model was fabricated with a 3D printer based on the data acquired from the 3D rotational angiogram. A hollow aneurysm model with an identical vessel and aneurysm lumen to the actual anatomy was constructed with use of the solid model as a mold. With use of the solid model, a microcatheter shaping mandrel was formed to identically line the 3D curvature of the parent vessel and the long axis of the aneurysm. With use of the mandrel, a test microcatheter was shaped and validated for the accuracy with the hollow model. All the planning processes were undertaken at least 1 day before treatment. The preshaped mandrel was then applied in the endovascular procedure. Ten consecutive intracranial aneurysms were coiled with the pre-planned shape of the microcatheter and evaluated for the clinical and anatomical outcomes and microcatheter accuracy and stability. All of pre-planned microcatheters matched the vessel and aneurysm anatomy. Seven required no microguidewire assistance in catheterizing the aneurysm whereas 3 required guiding of a microguidewire. All of the microcatheters accurately aligned the long axis of the aneurysm. The pre-planned microcatheter shapes demonstrated stability in all except in 1 large aneurysm case. When a 3D printing rapid type prototyping technology is used, a patient-specific and optimal microcatheter shape may be determined preoperatively. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Endovascular treatment of basilar and ICA termination aneurysms: effects of the use of HydroCoils on treatment stability in a subgroup of patients prone to a higher recurrence rate

    International Nuclear Information System (INIS)

    Geyik, Serdar; Yavuz, Kivilcim; Cekirge, Saruhan; Saatci, Isil

    2007-01-01

    The aim of this study was to evaluate the stability of occlusion of terminal bifurcation aneurysms after embolization with hydrogel-coated coils. Of 35 bifurcation aneurysms, 34 were treated with hydrogel-coated coils in combination with platinum coils, and 1 was treated with hydrogel-coated coils only. Aneurysms were located at the basilar tip in 17 patients, and the internal carotid artery (ICA) bifurcation in 18 patients. The patient population consisted of 20 women and 15 men with ages ranging from 21 to 65 years. The aneurysm was found in 16 patients on presentation for subarachnoid hemorrhage, and in 19 patients the finding was incidental. Of the 35 aneurysms, 25 were small, 9 were large and 1 was giant. The giant aneurysm was located at the basilar tip and showed partial thrombosis. All except two basilar tip aneurysms were treated with balloon assistance. The remaining two basilar tip aneurysms were embolized with the assistance of an aneurysmal neck bridge device. The mean percentage occluded aneurysm volume for all devices was in the range 34-100%. Follow-up angiograms were obtained at 1 year in 6 patients, 2 years in 11 patients, and 3 years in 18 patients. Angiograms obtained immediately after embolization demonstrated a Raymond class 1 occlusion in 29 patients (82.9%) and a Raymond class 2 occlusion in 6 patients (17.1%). In four of these six patients follow-up angiograms demonstrated regrowth with resultant Raymond class 3 occlusion. In the other two patients, Raymond class 2 occlusion remained stable on follow-up angiograms. In patients who had a Raymond class 1 occlusion on the angiogram obtained immediately after embolization, no regrowth was seen on the follow-up angiograms. The overall recanalization rate was 11.4% (three large, one giant) at 6 months. Retreatment was not considered in three of these patients and they were to be followed; the other patient was retreated. Our initial procedural data demonstrate that higher volumetric occlusion was

  1. Endovascular treatment of basilar and ICA termination aneurysms: effects of the use of HydroCoils on treatment stability in a subgroup of patients prone to a higher recurrence rate

    Energy Technology Data Exchange (ETDEWEB)

    Geyik, Serdar; Yavuz, Kivilcim; Cekirge, Saruhan; Saatci, Isil [Hacettepe University Hospital, Interventional Neuroradiology Unit, Radiology Department, Ankara (Turkey)

    2007-12-15

    The aim of this study was to evaluate the stability of occlusion of terminal bifurcation aneurysms after embolization with hydrogel-coated coils. Of 35 bifurcation aneurysms, 34 were treated with hydrogel-coated coils in combination with platinum coils, and 1 was treated with hydrogel-coated coils only. Aneurysms were located at the basilar tip in 17 patients, and the internal carotid artery (ICA) bifurcation in 18 patients. The patient population consisted of 20 women and 15 men with ages ranging from 21 to 65 years. The aneurysm was found in 16 patients on presentation for subarachnoid hemorrhage, and in 19 patients the finding was incidental. Of the 35 aneurysms, 25 were small, 9 were large and 1 was giant. The giant aneurysm was located at the basilar tip and showed partial thrombosis. All except two basilar tip aneurysms were treated with balloon assistance. The remaining two basilar tip aneurysms were embolized with the assistance of an aneurysmal neck bridge device. The mean percentage occluded aneurysm volume for all devices was in the range 34-100%. Follow-up angiograms were obtained at 1 year in 6 patients, 2 years in 11 patients, and 3 years in 18 patients. Angiograms obtained immediately after embolization demonstrated a Raymond class 1 occlusion in 29 patients (82.9%) and a Raymond class 2 occlusion in 6 patients (17.1%). In four of these six patients follow-up angiograms demonstrated regrowth with resultant Raymond class 3 occlusion. In the other two patients, Raymond class 2 occlusion remained stable on follow-up angiograms. In patients who had a Raymond class 1 occlusion on the angiogram obtained immediately after embolization, no regrowth was seen on the follow-up angiograms. The overall recanalization rate was 11.4% (three large, one giant) at 6 months. Retreatment was not considered in three of these patients and they were to be followed; the other patient was retreated. Our initial procedural data demonstrate that higher volumetric occlusion was

  2. Wingspan stent-assisted coiling of intracranial aneurysms with symptomatic parent artery stenosis: Experience in 35 patients with mid-term follow-up results

    International Nuclear Information System (INIS)

    Gao Xu; Liang Guobiao; Li Zhiqing; Wei Xuezhong; Wang Xiaogang; Zhang Haifeng; Feng Sizhe; Lin Jun

    2012-01-01

    Background: There is a potential risk of aneurysm rupture after parent artery revascularization because of increased blood flow. The purpose of this study is to assess the efficacy and safety of Wingspan stent-assisted coil embolization in the treatment of intracranial aneurysms with symptomatic parent artery stenosis. Methods: Thirty-five consecutive patients (19 men, 16 women; age range, 48–79 years; mean age, 60.4 years) harboring 35 unruptured wide-necked or fusiform intracranial aneurysms (mean size 6.8 mm; range 2.5–18 mm.) with symptomatic parent artery stenosis (mean degree 71.1%; range 50–92%) were treated with the Wingspan stent-assisted coiling. Twenty-four lesions were located in the anterior circulation and eleven in the posterior circulation. Patients were premedicated with antiplatelet therapy consisting of aspirin 300 mg and clopidogrel 75 mg for at least 3 days before the procedure. Following pre-dilatation and stent placement, a coiling microcatheter entered the aneurysm through the interstices of the stent, and then coiling was performed. After the procedure, clopidogrel 75 mg daily was recommended for an additional 30 days, and aspirin 100 mg was recommended throughout follow-up. For all patients, clinical follow-up was conducted by clinic visitation, or telephone interview. Angiographic follow-up with DSA was recommended at 6 months and 1 year after the procedure. Angiography follow-up (mean time 10.6 months) was obtained in 31 cases (88.6%). The technical feasibility of the procedure, procedure-related complications, angiographic results, clinical outcome and follow-up angiography were evaluated. Results: In every case, technical success was achieved. The degree of stenosis was reduced from 71.1% to 17.4% after balloon angioplasty and stenting. Immediate angiography demonstrated complete occlusion in 25 cases (71.4%), neck remnant in 7 cases (20.0%), and incomplete occlusion in 3 cases (8.6%). Procedure-related morbidity occurred in two

  3. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  4. The Barrel vascular reconstruction device for endovascular coiling of wide-necked intracranial aneurysms: a multicenter, prospective, post-marketing study.

    Science.gov (United States)

    Gory, Benjamin; Blanc, Raphaël; Turjman, Francis; Berge, Jérôme; Piotin, Michel

    2018-02-02

    The Barrel vascular reconstruction device (Barrel VRD) is a novel stent with design features that allow endovascular coiling of wide-necked bifurcation aneurysms while preserving adjacent branches, without necessitating dual stent implantation. This study aimed to assess the safety and effectiveness of the Barrel VRD at 12-month follow-up. The Barrel VRD trial is a prospective, multicenter, observational post-marketing registry evaluating the use of the Barrel VRD for treatment of wide-necked bifurcation aneurysms. The primary effectiveness endpoint was successful aneurysm treatment measured by digital subtraction angiography with a Raymond-Roy occlusion grade of 1 or 2 in the absence of retreatment, parent artery stenosis (>50%), or target aneurysm rupture at 12 months. The primary safety endpoint was the absence of neurological death or major stroke at 12 months. Twenty patients were enrolled from December 2013 to December 2014. The device was implanted in 19 patients with 19 aneurysms (8 middle cerebral artery, 4 anterior communicating artery, 1 internal carotid artery terminus, 4 basilar artery aneurysms; mean dome height 5.7±1.91 mm; mean neck length 4.8±1.35 mm, mean dome-to-neck ratio 1.6±2.0). Coiling was performed in all cases. The primary effectiveness endpoint was achieved in 78.9% of subjects (15/19; 12 complete occlusions, 3 neck remnants), and the primary safety endpoint was 5.3% (1/19). This prospective study demonstrates that the Barrel VRD device resulted in ~80% occlusion rates and ~5% rates of neurological complications at 1 year after endovascular treatment of wide-necked bifurcation intracranial aneurysms. REGISTERED CLINICAL TRIAL: NCT02125097;Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. A Systematic Review and Meta-Analysis on Economic Comparison Between Endovascular Coiling Versus Neurosurgical Clipping for Ruptured Intracranial Aneurysms.

    Science.gov (United States)

    Zhang, Xiaoxi; Li, Li; Hong, Bo; Xu, Yi; Liu, Yuan; Huang, Qinghai; Liu, Jianmin

    2018-05-01

    Healthcare expenditures and cost reduction have been under critical surveillance in all countries and are critical for policymakers. This review aims at qualitatively and quantitatively analyzing the difference of hospital costs and length of stay between endovascular coiling versus neurosurgical clipping in ruptured intracranial aneurysms (RAs). MEDLINE, the Cochrane database, Embase, and the Web of Science database were searched and evaluated independently by 2 authors according to the Newcastle-Ottawa Scale for cohort studies describing economic hospital cost or length of stay in patients with RAs. A total of 8 studies were included, describing 24,219 RAs treated with neurosurgical clipping and 24,962 RAs with endovascular coiling. Meta-analysis revealed that the total hospital costs (THCs) were similar between coiling versus clipping in RAs (standard mean difference [SMD], -0.05; 95% confidence interval [CI], -0.12 to 0.22; I 2  = 99%; P = 0.50). Subgroup analysis showed that THCs of clipping and coiling were similar in ruptured aneurysms in the United States. However, in South Korea, the THCs of coiling were significantly higher than clipping. In the long run, 1-year medical costs of endovascular treatment were significantly lower than that of clipping in RAs (SMD, 0.15; 95% CI, 0.05-0.25; I 2  = 66%; P = 0.005). In addition, the length of stay of coiled patients was significantly shorter than clipped patients (SMD, 0.29; 95% CI, 0.13-0.45; I 2  = 96%; P China, coiling was more expensive. The length of stay was much shorter in coiled patients in all countries. Copyright © 2018. Published by Elsevier Inc.

  6. Epistaxis revealing the rupture of a carotid aneurysm of the cavernous sinus extending into the sphenoid: treatment using an uncovered stent and coils. Review of literature.

    Science.gov (United States)

    Lehmann, Pierre; Saliou, Guillaume; Page, Cyril; Balut, Antonia; Le Gars, Daniel; Vallée, Jean Noel

    2009-05-01

    True carotid aneurysms with sphenoid extension and revealed by epistaxis are rare. A review of the literature shows the mortality risk of this pathology and the different therapeutic options. A 41-year-old female presented with a cavernous carotid aneurysm with sphenoid extension revealed by massive epistaxis. We propose a combined treatment of the affected vessel using coils and an uncovered stent. The first stage to stop the hemorrhages and occlude the aneurysm using the coil and the second stage several days later after anticoagulation using the stent to prevent revascularization. This treatment has been shown to be effective in producing immediate hemostasis and stable long-term occlusion.

  7. Multiple Enlarged Aneurysms in Primary Racemose Hemangioma of the Bronchial Artery: Successful Prophylactic Transcatheter Arterial Embolization Using N-butyl-2-cyanoacrylate and Coils.

    Science.gov (United States)

    Saiga, Atsushi; Sugiura, Toshihiko; Higashide, Takashi; Tsuchiya, Satoshi; Nishiyama, Akira; Kubota, Yoshihiro; Horikoshi, Takuro; Uno, Takashi

    2018-05-01

    An asymptomatic 48-year-old man presented with multiple aneurysms in a primary racemose hemangioma of the right bronchial artery. Bronchial arteriography revealed a tortuous artery with four fusiform aneurysms of varying sizes and aneurysmal dilatation with marked thrombus formation in the long segment of the distal portion. Because the tip of catheter could not pass beyond the aneurysmal dilatation, we performed balloon-occluded embolization using a mixture of N-butyl-2-cyanoacrylate (NBCA) and iodized oil. For four other aneurysms, we performed embolization using a coil alone or with NBCA. After 6 months, right bronchial arteriography revealed no enhancement of the aneurysms. Despite the rarity of this procedure, embolization with NBCA is a good option for bronchial artery aneurysm embolization.

  8. Preoperative coiling of coexisting intracranial aneurysm and subsequent brain tumor surgery

    Energy Technology Data Exchange (ETDEWEB)

    Park, Keun Young; Kim, Byung Moon; Kim, Dong Joon [Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    Few studies have investigated treatment strategies for brain tumor with a coexisting unruptured intracranial aneurysm (cUIA). The purpose of this study was to evaluate the safety and efficacy of preoperative coiling for cUIA, and subsequent brain tumor surgery. A total of 19 patients (mean age, 55.2 years; M:F = 4:15) underwent preoperative coiling for 23 cUIAs and subsequent brain tumor surgery. Primary brain tumors were meningiomas (n = 7, 36.8%), pituitary adenomas (n = 7, 36.8%), gliomas (n = 3, 15.8%), vestibular schwannoma (n = 1, 5.3%), and Rathke's cleft cyst (n = 1, 5.3%). cUIAs were located at the distal internal carotid artery (n = 9, 39.1%), anterior cerebral artery (n = 8, 34.8%), middle cerebral artery (n = 4, 17.4%), basilar artery top (n = 1, 4.3%), and posterior cerebral artery, P1 segment (n = 1, 4.3%). The outcomes of preoperative coiling of cUIA and subsequent brain tumor surgery were retrospectively evaluated. Single-microcatheter technique was used in 13 cases (56.5%), balloon-assisted in 4 cases (17.4%), double-microcatheter in 4 cases (17.4%), and stent-assisted in 2 cases (8.7%). Complete cUIA occlusion was achieved in 18 cases (78.3%), while residual neck occurred in 5 cases (21.7%). The only coiling-related complication was 1 transient ischemic attack (5.3%). Neurological deterioration did not occur in any patient during the period between coiling and tumor surgery. At the latest clinical follow-up (mean, 29 months; range, 2-120 months), 15 patients (78.9%) had favorable outcomes (modified Rankin Scale, 0-2), while 4 patients (21.1%) had unfavorable outcomes due to consequences of brain tumor surgery. Preoperative coiling and subsequent tumor surgery was safe and effective, making it a reasonable treatment option for patients with brain tumor and cUIA.

  9. Preoperative coiling of coexisting intracranial aneurysm and subsequent brain tumor surgery

    International Nuclear Information System (INIS)

    Park, Keun Young; Kim, Byung Moon; Kim, Dong Joon

    2016-01-01

    Few studies have investigated treatment strategies for brain tumor with a coexisting unruptured intracranial aneurysm (cUIA). The purpose of this study was to evaluate the safety and efficacy of preoperative coiling for cUIA, and subsequent brain tumor surgery. A total of 19 patients (mean age, 55.2 years; M:F = 4:15) underwent preoperative coiling for 23 cUIAs and subsequent brain tumor surgery. Primary brain tumors were meningiomas (n = 7, 36.8%), pituitary adenomas (n = 7, 36.8%), gliomas (n = 3, 15.8%), vestibular schwannoma (n = 1, 5.3%), and Rathke's cleft cyst (n = 1, 5.3%). cUIAs were located at the distal internal carotid artery (n = 9, 39.1%), anterior cerebral artery (n = 8, 34.8%), middle cerebral artery (n = 4, 17.4%), basilar artery top (n = 1, 4.3%), and posterior cerebral artery, P1 segment (n = 1, 4.3%). The outcomes of preoperative coiling of cUIA and subsequent brain tumor surgery were retrospectively evaluated. Single-microcatheter technique was used in 13 cases (56.5%), balloon-assisted in 4 cases (17.4%), double-microcatheter in 4 cases (17.4%), and stent-assisted in 2 cases (8.7%). Complete cUIA occlusion was achieved in 18 cases (78.3%), while residual neck occurred in 5 cases (21.7%). The only coiling-related complication was 1 transient ischemic attack (5.3%). Neurological deterioration did not occur in any patient during the period between coiling and tumor surgery. At the latest clinical follow-up (mean, 29 months; range, 2-120 months), 15 patients (78.9%) had favorable outcomes (modified Rankin Scale, 0-2), while 4 patients (21.1%) had unfavorable outcomes due to consequences of brain tumor surgery. Preoperative coiling and subsequent tumor surgery was safe and effective, making it a reasonable treatment option for patients with brain tumor and cUIA

  10. Combined treatment for complex intracranial aneurysm

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2015-06-01

    Full Text Available Complex aneurysms often cannot be completely excluded by a single approaches. Today successful treatment of these lesions requires a combination between microsurgical and endovascular techniques. Planning of combined treatment require a very good understanding of aneurysm anatomy and a close collaboration between neurosurgeon and neuroendovascular interventionist. Endovascular coiling can usually be used as early treatment for a partially aneurysm occlusion including the ruptured area and followed by definitive clipping. On the other hand microsurgical clipping also can be used as first treatment for complex aneurysm neck reconstruction, allowing successful secondary placement of coils inside the remnant aneurysm sac

  11. Spiral versus J-shaped coils for neurovascular embolisation - an in-vitro study

    International Nuclear Information System (INIS)

    Sugiu, K.; Tokunaga, K.; Mandai, S.; Martin, J.B.; Jean, B.; Ruefenacht, D.A.

    2003-01-01

    Our purpose was to compare the characteristics of J-shaped detachable platinum coils with those of spiral coils in in-vitro vascular models. J-shaped coils consist of distal semicircular and proximal straight segments, the latter extending for most of the length of the coil. Spiral coils have a helical shape memory and are thus limited in expansion. In in-vitro silicone vascular models simulating intracranial aneurysms and dural arteriovenous fistulae, we compared J-shaped and spiral coils with regard to ease of delivery, anchoring and folding patterns, and stability in various types of vascular lumen. Delivery and retrieval were comparable. In large and irregular aneurysms and venous sinuses, J-shaped coils could form a more complex basket which conformed to the shape of the vascular cavity. The J-shaped coil was always in contact with the vessel wall. In wide-necked aneurysms, coil protrusion was more frequent with J-shaped coils, while spiral coils tended to stay compact and circular. Arteries were occluded in a shorter segment with spiral coils. J-shaped coils were safe and superior for large and irregular aneurysms or sinuses. Spiral coils were preferable for spherical aneurysms and segmental occlusion of arteries. (orig.)

  12. Reversible Edema-Like Changes Along the Optic Tract Following Pipeline-Assisted Coiling of a Large Anterior Communicating Artery Aneurysm.

    Science.gov (United States)

    La Pira, Biagia; Brinjikji, Waleed; Hunt, Christopher; Chen, John J; Lanzino, Giuseppe

    2017-06-01

    Aneurysmal volume expansion after endovascular treatment is caused by intra-aneurysmal thrombosis in the early postembolization period. Although postembolization mass effect on cranial nerves and other adjacent structures has been previously reported, we are unaware of reports involving the anterior visual pathway. A 66-year-old woman with a 2-week history of blurred vision without headache was found to have a large, unruptured anterior communicating artery aneurysm. One month after endovascular treatment of the aneurysm with coiling and flow diversion, the patient developed decreased vision in her right eye and a left homonymous hemianopia. Magnetic resonance imaging demonstrated compression of the right optic nerve, chiasm, and edema of the right optic tract. The patient was treated with a course of high dose corticosteroids, and over the course of several weeks, her vision improved and the optic tract edema resolved. We alert clinicians to this rare but potentially reversible visual complication of endovascular treatment of intracranial aneurysms.

  13. Long-term follow-up of aneurysms treated electively with woven stent-assisted coiling.

    Science.gov (United States)

    Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew K; Wenderoth, Jason D

    2017-12-15

    Preliminary short-term results for stent-assisted coil embolization (SACE) using woven/braided stents have been promising. However, evidence supporting mid- to long-term efficacy and durability is lacking. To report the long-term results for the durability of elective intracranial aneurysms treated with woven stents. Between May 2012 and May 2015, 98 consecutive patients with 103 aneurysms underwent elective woven SACE across three Australian neurovascular centres. All patients had immediate, 6- and 18-month clinical and radiological follow-up. Radiological assessment was performed with modified Raymond-Roy occlusion scores based on angiography results, while clinical assessment was based on the modified Rankin Scale. Six-month follow-up was available in 100 aneurysms, and an 18-month follow-up in 97 aneurysms. Total occlusion rates of 82% were achieved at inception, 82% at 6 months, and 90% at 18 months. Satisfactory occlusion with small neck remnants was present in 17% at inception, 16% at 6 months, and 9% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Intraprocedural thromboembolic events were recorded in 3% and delayed events in 1% (all in patients taking clopidogrel). Aneurysm recurrence occurred in one patient (1%). Technical complications occurred in 5%. The total complication rate was 10%. Woven SACE is safe, efficacious, and durable at long-term 18-month follow-up, with very low recurrence and re-treatment rates. Preliminary results appear better than those for traditional laser-cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Individualized management for intracranial vertebral artery dissecting aneurysms

    Directory of Open Access Journals (Sweden)

    SHANG Yan-guo

    2012-02-01

    Full Text Available Objective To discuss the individualized management strategy for intracranial vertebral artery dissecting aneurysms. Methods Eighteen patients with intracranial vertebral artery dissecting aneurysms were treated with different surgical methods. Results Eighteen patients underwent different surgical treatment. Five patients underwent complete occlusion of the aneurysm and parent artery by coiling, 5 were treated by stent -assisted coiling (3 densely packed coiling and 2 non-densely packed coiling, 4 underwent stent-only therapy and 3 of them presented hemodynamic improvement after surgery, 3 were treated by direct surgical clipping, and 1 underwent occipital artery-posterior inferior cerebellar artery bypass. Two aneurysms ruptured immaturely, in which one patient died on the third day after operation and one patient occurred moderate disablity. Only 1 patient who underwent complete occlusion of aneurysm and parent artery presented temporarily ischemic symptoms. No adverse effects were seen in other patients. Seventeen patients were followed up for 1 month to 3 years, and all the aneurysms were stable. Conclusion There are many kinds of therapeutic methods for intracranial vertebral artery dissecting aneurysms. The patients should be treated according to several factors such as the clinical manifestations, aneurysm configuration, and relationship with the posterior inferior cerebellar artery. The treatment should be individualized.

  15. HydroCoils, occlusion rates, and outcomes: a large single-center study.

    LENUS (Irish Health Repository)

    O'Hare, A M

    2010-11-01

    The HydroCoil is an expansile hydrogel coil designed to produce a greater degree of volumetric packing within cerebral aneurysms when compared with bare platinum coils. This increased packing is, in turn, believed to decrease the risk of recurrence within aneurysms and hence the risk of their rupture in the long term. The aim of this work was to assess whether the use of HydroCoils and the proportion of HydroCoil used have any influence on the subsequent occlusion and recurrence rates of treated aneurysms.

  16. Complete Obliteration of a Basilar Artery Aneurysm after Insertion of a Self- Expandable Leo Stent into the Basilar Artery without Coil Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Juszkat, Robert; Nowak, Stanis Aw; Wieloch, Micha; Zarzecka, Anna [Poznan University of Medical Sciences, Poznan (Poland)

    2008-08-15

    We report a case of a 45-year-old man who underwent endovascular treatment in the acute setting of a subarachnoid hemorrhage due to rupture of a widenecked basilar trunk aneurysm. The patient was treated with stent implantation without coiling. A control angiographic scan obtained immediately after the procedure revealed significantly decreased intraaneurysmal flow. Follow-up angiography performed after one month demonstrated total aneurysm occlusion.

  17. Stenting plus coiling: dangerous or helpful?; Stenting plus Coiling bei akut rupturierten intrakraniellen Aneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, I.; Gizewski, E.; Doerfler, A.; Stolke, D.; Forsting, M. [Essen Univ. (Germany). Inst. fuer Radiologie und Neuroradiologie

    2005-09-01

    Purpose: the purpose of this study was to evaluate the procedural risk of treating acute ruptured aneurysms with a stentcoil combination. Material and methods: between August 2001 and January 2004 we treated nine acute subarachnoid hemorrhage (SAH) patients with a combination of stents and platinum coils. Results: six aneurysms were 100% eliminated; the residual three aneurysms had a 95% to 99% occlusion. A transient thrombosis in the stent in one patient could be recanalized by intravenous application of ReoPro {sup registered}. In another patient an occlusive vasospasm at the distal end of the stent was successfully treated with intraarterial Nimotop {sup registered}. Neurological complications occurred in none of the patients. Conclusion: in broad-based aneurysms which cannot be clipped or in which any neurosurgical treatment presents an unacceptably high risk (posterior circulation and paraophthalmic aneurysms), treatment using a combination of stent and platinum coils might be an option even in the acute phase of an SAH. Platelet aggregation can be treated with Aspirin registered and Plavix {sup registered} after placement of the first coil, vasospasms with intraarterial Nimotop {sup registered}, and acute stent thrombosis with GP IIa/IIIb-antagonists. (orig.)

  18. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio

    2014-01-01

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  19. Interventional procedures of the isolated iliac arterial aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine, Bucheon (Korea, Republic of); Shin, Byung Seok; Ahn, Moon Sang [Chungnam National Univ. Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-05-15

    To report the results of treatment isolated iliac arterial aneurysms by interventional procedures. Over a period of 5 years, 7 isolated iliac artery aneurysms (4 in the common iliac artery, 3 in the internal iliac artery) in 7 patients (3 women, 4 men; mean age, 65.7 years) were treated using interventional procedures. The mean aneurysm size was 35 mm (range, 30-45 mm). The common iliac aneurysms were treated using a unilateral stent graft (2 balloon expandable, 2 self expandable) with coil embolization of the internal iliac artery (n = 3), except for 1 aneurysm that ruptured. Coil embolization alone was performed for aneurysms involving only the internal iliac artery (n = 3). All patients were treated successfully, except for 1 with an initial remnant of type 2 endoleak. There were no perioperative complications. No leakage or complication occurred at the mean follow up of 14 months (range 2-29 months). One patient with a ruptured aneurysm died of multi organ failure during the follow up period. Three aneurysms had decreased in size on follow up CT. Interventional procedures with stent grafting and coil embolization are safe and effective treatments for isolated iliac artery aneurysms.

  20. Application of dual volume reconstruction technique in embolization of intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Xiang-hai ZHANG

    2014-03-01

    Full Text Available Objective To explore the value of dual volume reconstruction technique in Guglielmi detachable coil (GDC embolization of intracranial aneurysms. Methods Three-dimensional imaging data of 20 patients received GDC embolization of intracranial aneurysms from Jun. 2012 to Apr. 2013 were analyzed for dual volume reconstruction. The value of application of dual volume reconstruction was evaluated by the detection rate of coils bolus, degree of aneurysm occlusion, the length of aneurysm sac and aneurysm neck before and after embolization, and the characteristics and clinical value of the reconstructed images. Results  A total of 20 coil boluses were detected by dual volume reconstruction images, and the detection rate was 100%. Among all of 20 patients, no visualization of contrast medium in the aneurysm was found in 13 patients, while contrast agent was found in the aneurysm sac in 3 patients and in the aneurysm neck in 4 patients. The length of aneurysm neck and sac was somewhat changed before and after embolization with no statistically significant difference (P>0.05. The dual volume reconstruction could reveal coil bolus, vessels, cranium and fusion images, and the aneurysms could be shown by different imaging modes according to the clinical requirement. Conclusion Dual volume reconstruction technique can display the location of coil bolus, degree of occlusion and aneurysm size, and evaluate the embolization effect by multifarious imaging modes, providing a great deal of information for the evaluation of GDC embolization of intracranial aneurysm. DOI: 10.11855/j.issn.0577-7402.2014.02.13

  1. Successful Transarterial Guglielmi Detachable Coil Embolization of Post-Traumatic Fistula between a Posterior Communicating Artery Aneurysm and the Cavernous Sinus

    Science.gov (United States)

    Chen, Y.; Jiang, D-Y.; Tan, H-Q.; Wang, L-H.; Chen, X-Y.; Sun, J-H.

    2009-01-01

    Summary We describe a case of a post-traumatic posterior communicating artery (PCoA) aneurysmcavernous sinus fistula, which is an extremely rare complication of craniocerebral trauma, successfully treated with endosaccular coil embolization via transarterial route. Endosaccular embolization with Guglielmi detachable coils via transarterial route appears to be a feasible, effective and minimally invasive option for the treatment of post-traumatic fistula between the PCoA aneurysm with a small ostia and the cavernous sinus in the subacute phase. PMID:20465883

  2. Intracranial Aneurysms of Neuro-Ophthalmologic Relevance.

    Science.gov (United States)

    Micieli, Jonathan A; Newman, Nancy J; Barrow, Daniel L; Biousse, Valérie

    2017-12-01

    Intracranial saccular aneurysms are acquired lesions that often present with neuro-ophthalmologic symptoms and signs. Recent advances in neurosurgical techniques, endovascular treatments, and neurocritical care have improved the optimal management of symptomatic unruptured aneurysms, but whether the chosen treatment has an impact on neuro-ophthalmologic outcomes remains debated. A review of the literature focused on neuro-ophthalmic manifestations and treatment of intracranial aneurysms with specific relevance to neuro-ophthalmologic outcomes was conducted using Ovid MEDLINE and EMBASE databases. Cavernous sinus aneurysms were not included in this review. Surgical clipping vs endovascular coiling for aneurysms causing third nerve palsies was compared in 13 retrospective studies representing 447 patients. Complete recovery was achieved in 78% of surgical patients compared with 44% of patients treated with endovascular coiling. However, the complication rate, hospital costs, and days spent in intensive care were reported as higher in surgically treated patients. Retrospective reviews of surgical clipping and endovascular coiling for all ocular motor nerve palsies (third, fourth, or sixth cranial nerves) revealed similar results of complete resolution in 76% and 49%, respectively. Improvement in visual deficits related to aneurysmal compression of the anterior visual pathways was also better among patients treated with clipping than with coiling. The time to treatment from onset of visual symptoms was a predictive factor of visual recovery in several studies. Few reports have specifically assessed the improvement of visual deficits after treatment with flow diverters. Decisions regarding the choice of therapy for intracranial aneurysms causing neuro-ophthalmologic signs ideally should be made at high-volume centers with access to both surgical and endovascular treatments. The status of the patient, location of the aneurysm, and experience of the treating physicians

  3. Successful Retreatment of Recurrent Intracranial Vertebral Artery Dissecting Aneurysms After Stent-Assisted Coil Embolization: A Self-Controlled Hemodynamic Analysis.

    Science.gov (United States)

    Liu, Jian; Jing, Linkai; Zhang, Ying; Song, Ying; Wang, Yang; Li, Chuanhui; Wang, Yanmin; Mu, Shiqing; Paliwal, Nikhil; Meng, Hui; Linfante, Italo; Yang, Xinjian

    2017-01-01

    Intracranial vertebral artery dissecting aneurysms (VADAs) tend to recur despite successful stent-assisted coil embolization (SACE). Hemodynamics is useful in evaluating aneurysmal formation, growth, and rupture. Our aim was to evaluate the hemodynamic patterns of the recurrence of VADA. Between September 2009 and November 2013, all consecutive patients with recurrent VADAs after SACE in our institutions were enrolled. Recurrence was defined as recanalization and/or regrowth. We assessed the hemodynamic alterations in wall shear stress (WSS) and velocity after the initial SACE and subsequently after retreatment of the aneurysms that recurred. Five patients were included. After the initial treatment, 3 patients showed recanalization and 2 showed regrowth. In the 2 patients with regrowth, the 2 original aneurysms maintained complete occlusion; however, de novo aneurysm regrowth was confirmed near the previous site. Compared with 3 recanalized aneurysms, the completely occluded aneurysms showed high mean reductions in velocity and WSS after initial treatment (velocity, 77.6% vs. 57.7%; WSS, 74.2% vs. 52.4%); however, WSS remained high at the region near the previous lesion where the new aneurysm originated. After the second retreatment, there was no recurrence in any patient. Compared with the 3 aneurysms that recanalized, the 4 aneurysms that maintained complete occlusion showed higher reductions in velocity (62.9%) and WSS (71.1%). Our series indicated that hemodynamics might have an important role in recurrence of VADAs. After endovascular treatment, sufficient hemodynamic reduction in aneurysm dome, orifice, and parent vessel may be one of the key factors for preventing recurrence in VADAs. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Microembolic signal monitoring and the prediction of thromboembolic events following coil embolization of unruptured intracranial aneurysms: diffusion-weighted imaging correlation

    International Nuclear Information System (INIS)

    Cho, Jae-Hoon; Park, Jaechan; Kang, Dong-Hun; Kim, Yong-Won; Kim, Yong-Sun

    2015-01-01

    Microembolic signal (MES) monitoring with transcranial Doppler ultrasonography (TCD) may allow for early prediction of thromboembolisms following endovascular coiling of unruptured intracranial aneurysms (UIAs). However, the method has not gained widespread use and may benefit from correlation with diffusion-weighted imaging (DWI) of acute ischemic lesions after coiling. This purposed to evaluate the relationship between MESs and DWI-positive lesions more precisely. We conducted a prospective study on 45 consecutive patients. TCD was performed over the artery that is dependent on the site of aneurysm, but seven patients (15.6 %) could not be examined due to the lack of an adequate cranial window. Consequently, 38 patients were available to detect MESs immediately (MES-1) and 24 h (MES-2) after coiling for UIAs. We also checked DWI 1 day after the coiling and analyzed correlations between the TCD and DWI findings. MES-1 and MES-2 were positive in 25 (65.7 %) and 14 (36.8 %) patients, respectively. DWI-positive lesions were seen in 20 (52.6 %) patients, and only 1 (2.6 %) patient was symptomatic. MES-1 and MES-2 were strongly correlated with the number of DWI-positive lesions (Spearman's correlation coefficient = 0.79 and 0.70, P < 0.01 and P < 0.01, respectively). Additionally, there was a significant correlation between MES-1 and MES-2 (Spearman's correlation coefficient = 0.70). Based upon the significant correlation between MES and DWI findings, MES may have a role for early detection of ischemic complications after coiling of UIAs. In addition, future study for further validation with clinical application seems requiring. (orig.)

  5. Endovascular treatment for pediatric intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Xianli; Jiang, Chuhan; Li, Youxiang; Yang, Xinjian; Wu, Zhongxue [Capital Medical University, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Beijing, Hebei (China)

    2009-11-15

    The purpose of this study is to report the characteristics and outcomes of pediatric patients with intracranial aneurysms. From 1998 to 2005, 25 pediatric patients (aged {<=}17 years) with intracranial aneurysm were treated at our institute. Eleven of 25 patients had subarachnoid hemorrhage. In ten patients, the aneurysm was an incidental finding. One patient presented with cranial nerves dysfunction and three with neurological deficits. The locations of the aneurysms were as follows: vertebral artery (VA; n = 9), middle cerebral artery (MCA; n = 5), posterior cerebral artery (PCA; n = 4), basilar artery (BA; n = 2), anterior communicating artery (n = 2), anterior cerebral artery (n = 2), and internal carotid artery (n = 1). Five patients were treated with selective embolization with coils. Sixteen patients were treated with parent vessel occlusion (PVO). Eight PVOs were performed with balloons and eight were performed with coils. One patient with a VA aneurysm was spontaneously thrombosed 4 days after the initial diagnostic angiogram. In three patients treated with stent alone or stent-assisted coiling, one with BA trunk aneurysm died. One aneurismal recurrence occurred and was retreated. At a mean follow-up duration of 23.5 months, 96% of patients had a Glasgow Outcome Scale score of 4 or 5. Pediatric intracranial aneurysms occur more commonly in male patients and have a predilection for the VA, PCA, and MCA. PVO is an effective and safe treatment for fusiform aneurysms. Basilar trunk fusiform aneurysms were difficult to treat and were associated with a high mortality rate. (orig.)

  6. Advances in endovascular aneurysm treatment: are we making a difference?

    International Nuclear Information System (INIS)

    Katz, Jeffrey M.; Ougorets, Igor; Tsiouris, Apostolos J.; Biondi, Alessandra; Salvaggio, Kimberly A.; Gobin, Y. Pierre; Stieg, Philip E.; Riina, Howard A.

    2005-01-01

    Recent advancements in endovascular aneurysm repair, including bioactive and expansile coils and intracranial stents, hold promise for improved aneurysm occlusion rates. We report the immediate and midterm clinical and angiographic outcomes of a consecutive series of patients treated since the advent of these technologies. Clinical and radiological records of 134 patients with 142 aneurysms treated between 2001 and 2004 were retrospectively evaluated by an independent neurologist. Endovascular procedures were analyzed by an independent neuroradiologist blinded to all clinical information. Seventy-two ruptured and 60 un-ruptured saccular aneurysms, nine fusiform and one post-traumatic aneurysm were treated. Matrix coils were used in 53% of saccular aneurysms and HydroCoils in 13% of all aneurysms. Neuroform stents were deployed in 19% of aneurysms. Angiographic total or subtotal occlusion was achieved in 76% of cases and in 96% at last follow-up. Aneurysm recanalization was observed in 14% over a mean follow-up of 12 months, and 18% of aneurysms were retreated. Clinically relevant complications occurred in 6.0%, resulting in procedure-related morbidity of 0.6% and 0.6% mortality at 6 months. No aneurysm bled over a cumulative 1,347 months of observation. Newer embolization technologies can be exploited successfully even in more complex aneurysms with very low morbidity and mortality. (orig.)

  7. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Gregor [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Kreisklinikum Siegen, Department of Radiology and Neuroradiology, Siegen (Germany); Pfister, Marcus [Siemens AG, Healthcare Sector, Forchheim (Germany); Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Spiegel, Martin; Hornegger, Joachim [University of Erlangen, Department of Informatics 5, Erlangen (Germany)

    2009-12-15

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  8. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    Richter, Gregor; Pfister, Marcus; Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd; Spiegel, Martin; Hornegger, Joachim

    2009-01-01

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  9. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms.

    LENUS (Irish Health Repository)

    Su, I-Chang

    2014-06-01

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development.

  10. Advances in open microsurgery for cerebral aneurysms.

    Science.gov (United States)

    Davies, Jason M; Lawton, Michael T

    2014-02-01

    Endovascular techniques introduced strong extrinsic forces that provoked reactive changes in aneurysm surgery. Microsurgery has become less invasive, more appealing to patients, lower risk, and efficacious for complex aneurysms, particularly those unfavorable for or failing endovascular therapy. To review specific advances in open microsurgery for aneurysms. A university-based, single-surgeon practice was examined for the use of minimally invasive craniotomies, surgical management of recurrence after coiling, the use of intracranial-intracranial bypass techniques, and cerebrovascular volume-outcome relationships. The mini-pterional, lateral supraorbital, and orbital-pterional craniotomies are minimally invasive alternatives to standard craniotomies. Mini-pterional and lateral supraorbital craniotomies were used in one-fourth of unruptured patients, increasing from 22% to 28%, whereas 15% of patients underwent orbital-pterional craniotomies and trended upward from 11% to 20%. Seventy-four patients were treated for coil recurrences (2.3% of all aneurysms) with direct clip occlusion (77%), clip occlusion after coil extraction (7%), or parent artery occlusion with bypass (16%). Intracranial-intracranial bypass (in situ bypass, reimplantation, reanastomosis, and intracranial grafts) transformed the management of giant aneurysms and made the surgical treatment of posterior inferior cerebellar artery aneurysms competitive with endovascular therapy. Centralization maximized the volume-outcome relationships observed with clipping. Aneurysm microsurgery has embraced minimalism, tailoring the exposure to the patient's anatomy with the smallest possible craniotomy that provides adequate exposure. The development of intracranial-intracranial bypasses is an important advancement that makes microsurgery a competitive option for complex and recurrent aneurysms. Trends toward centralizing aneurysm surgery in tertiary centers optimize results achievable with open microsurgery.

  11. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Machi, Paolo; Lobotesis, Kyriakos; Vendrell, Jean Francoise; Riquelme, Carlos; Eker, Omer; Costalat, Vincent; Bonafe, Alain

    2013-01-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues

  12. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  13. Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study

    International Nuclear Information System (INIS)

    Hans, F.J.; Thiex, R.; Gilsbach, J.M.; Krings, T.; Moeller-Hartmann, W.; Dreeskamp, H.; Stein, K.P.; Meetz, A.; Thron, A.; Pfeffer, J.; Scherer, K.; Brunn, A.

    2003-01-01

    Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms. (orig.)

  14. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self

  15. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    Science.gov (United States)

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  16. Dissecting Vertebral Artery Aneurysm Presenting Regrowth After Stent-Assisted Coil Embolization in Acute Stage.

    Science.gov (United States)

    Hijikata, Takamichi; Baba, Eiichi; Shirokane, Kazutaka; Tsuchiya, Atsushi; Nomura, Motohiro

    2018-06-01

    For a case of dissecting vertebral artery aneurysm (DVAA) in a dominant vertebral artery (VA) or posterior inferior cerebellar artery (PICA)-involving lesion, stent-assisted coil embolization (SACE) is an effective technique to preserve blood flow of the VA. A 41-year-old man presented with subarachnoid hemorrhage. Angiography demonstrated DVAA on the left VA just distal to the PICA, and the right VA was thinner than the left. For this case, SACE was performed to preserve the left VA and PICA. On the 10th day, angiography showed recurrence of the dissection. The dissected portion had thickened and extended to both distal and proximal sides involving the PICA origin and proximal portion to the PICA. A second endovascular embolization was performed and the recurrent dissecting aneurysm was embolized including the main VA cavity. In cases of DVAA, there is a possibility of recurrence after SACE, if a dissecting cavity remains unembolized. Therefore, total embolization is necessary under close observation from multiple angles, including the down-the-barrel view.

  17. Transient coronary aneurysm formation after Nevo™ stent implantation versus persistent coronary aneurysm after Cypher Select™ stent implantation

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Lassen, Jens Flensted; Jensen, Lisette Okkels

    2011-01-01

    We implanted a Cypher Select™ coronary stent and two months later a Nevo™ sirolimus-eluting coronary stent in another vessel. At a prescheduled angiographic follow-up, coronary aneurysms were seen in the two stented segments, 6 and 8 months after stent implantation, respectively. Six months later......, the aneurysm had healed in the Nevo, but was still present in the Cypher stented segment. We hypothesize that aneurysm formation was induced by sirolimus and the polymer of the implanted stents, and that subsequent healing was possible in the Nevo stent after degradation of the polymer....

  18. Reverse waffle cone technique in management of stent dislodgement into intracranial aneurysms.

    Science.gov (United States)

    Luo, Chao-Bao; Lai, Yen-Jun; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2013-09-01

    Stent-assisted coil embolization (SACE) is a common method to manage intracranial wide-neck aneurysm. Using this technique, a stent must be successfully deployed into the parent artery to cross the aneurysm neck. We describe the reverse waffle cone technique in management of intra-procedural stent dislodgement during SACE of internal carotid artery (ICA) wide-neck aneurysms. Two patients with unruptured wide-neck ICA aneurysms underwent SACE. Intra-procedural forward stent migration occurred during catheterization with proximal stent dislodgement and migration into the aneurysm sac. Navigation of a second stent to bridge the aneurysm neck failed in one patient because the second stent was impeded by the dislodged stent. Using the reverse waffle cone technique, a microcatheter was navigated into the aneurysm sacs. Coils were safely detached into each aneurysm sac without any device assistance. The two wide-neck aneurysms were successfully treated with preservation of flow to the internal carotid arteries. The complication of intra-procedural distal stent migration and dislodgement, with proximal stent prolapse into an aneurysm sac, may not result in a failure to coil the aneurysm. The reverse waffle cone technique provides an effective treatment in the management of this complication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Preliminary clinical study on endovascular treatment of posterior inferior cerebellar artery aneurysms

    International Nuclear Information System (INIS)

    Zhao Bing; Zhong Ming; Tan Xianxi; Zheng Kuang; Zhang Mingsheng; Yin Jian; He Wengen

    2009-01-01

    Objective: To study the methods and results of endovascular treatment of posterior inferior cerebellar artery (PICA) aneurysms. Methods: Twenty-one patients with PICA aneurysms were treated with endovascular treatment. The locations of aneurysm on PICA were evaluated through the DSA. Eight patients received single coil embolization, 5 received liquid Glue embolization, 2 received coil embolization combined with liquid Glue, 2 received coil embolization assisted with stents, and 4 underwent occlusion of the parent PICA. Outcome was evaluated with the Glasgow outcome scale (GOS). Results: There were complete (100%) occlusion in 5 patients, near complete (> 90%) occlusion in 2, and incomplete (85%) occlusion in 1 in single coil embolization. Seven patients with Glue embolization (n=5) or combination with coils (n=2) exhibited complete (100%) occlusion. There were near complete (>90%) occlusion in 2 cases with coil assisted with stents. Complete occlusion of the parent PICA was achieved in 3 patients, and near complete occlusion of PICA in one case. One patient suffered from new neurological deficits, and one patient treated with coils and stents died. None of the patients suffered from re-bleeding. There patients received follow-up during a mean period of (22 ± 8) months. Overall long-term outcome was good (GOS score 4 or 5) in 17 patients, poor (GOS score 2 or 3) in 3, and fatal (GOS score 1 ) in one case. Conclusions: According to the location of aneurysms on PICA, aneurysms can be effectively and safely treated with endovascular embolization. (authors)

  20. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  1. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  2. Parent artery occlusion for ruptured “true” posterior communicating artery aneurysm

    Science.gov (United States)

    Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-01-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. PMID:25953771

  3. Use of triple microcatheters for endovascular treatment of wide-necked intracranial aneurysms: A single center experience

    International Nuclear Information System (INIS)

    Cho, Young Dae; Rhim, Jong Kook; Kang, Hyun Seung; Kim, Jeong Eun; Cho, Won Sang; Han, Moon Hee; Park, Jeong Jin; Jeon, Jin Pyeong

    2015-01-01

    The dual microcatheter technique is common practice for coil embolization of a wide-necked aneurysm, due to safety and efficacy. However, technical limitations of some complex configurations may necessitate additional microcatheters to bolster coil stability, compact the coil, or for protection. Described herein is a triple microcatheter technique for endovascular management of wide-necked intracranial aneurysms. Data accruing prospectively between January 2006 and October 2014 on simultaneously executed triple microcatheter coil embolization procedures done in 38 saccular aneurysms were reviewed. Clinical and morphological outcomes were assessed, with emphasis on technical aspects of treatment. The triple microcatheter technique was successfully applied to all 38 saccular aneurysms, involving the posterior communicating artery (n = 13), the middle cerebral artery (n = 10), the basilar tip (n = 7), the anterior cerebral artery (n = 5), and the internal carotid artery (n = 3). Stent protection was added in four patients and balloon remodeling in one. Dual microcatheters (n = 24) were usually deployed to deliver the coil within sacs of aneurysms, with the additional microcatheter used for protection. Otherwise, triple microcatheters were deployed for coil delivery (n = 11) or coils were delivered via a single microcatheter, with dual microcatheters deployed for protection (n = 3). Successful occlusion of aneurysms was achieved in 89.5% of cases, with no procedure-related morbidity or mortality. Stable occlusion was maintained in 72.2% (26/36) of the aneurysms at the final follow-up (mean interval, 30.2 ± 22.7 months). The outcomes of this limited study suggest that the triple microcatheter technique may be an effective and safe therapeutic option for wide-necked aneurysms, using technical strategies tailored to complex angio-anatomic configurations

  4. Prevention and management of the complications during embolizing intracranial aneurysm with GDC

    International Nuclear Information System (INIS)

    Zhong Ming; Tan Xianxi; Wang Junlu; Hu Wenhao; Fan Lianghao

    2002-01-01

    Objective: To sum up the experience of embolization of intracranial aneurysm with Guglielmi detachable coil (GDC) and to discuss how to prevent and manage the complications during the endovascular treatment. Methods: 108 patients with intracranial aneurysm were embolized with GDC. 24 accident out of 20 patients during embolization were reviewed. Results: Among the 24 accidents, there were 10 aneurysm rupture, 5 over- embolization 5 coils end protruding to parent artery, and 4 thrombosis. Once the aneurysm ruptures, neutralizing heparin and continuing embolization was administered. Among 10 cases of aneurysm ruptures, 4 were death, 1 was severe deformity, 1 was mild deformity. Thrombolysis, heparinisation and raising blood pressure were used to control over-embolization, coil protrusion, and thrombosis. Among 5 cases of over-embolization, 1 died, 4 recovered. Among 5 cases of coils end protruding, 1 was severe deformity, 1 was mild deformity. Among 4 cases of embolization, 1 died, 1 was led sensory aphasics. The accidents resulted in 5 deaths (4.6%), 4 permanent neurological deficits (3.7%). Conclusion: The correct management of the complications during the treatment, the better understanding of the aneurysm and its parent artery angio-anatomy and the improved skill of embolizing technique are helpful to reduce the accidents and increase the cure rate

  5. Retreatment and outcomes of recurrent intracranial vertebral artery dissecting aneurysms after stent assisted coiling: a single center experience.

    Directory of Open Access Journals (Sweden)

    Ying Song

    Full Text Available The retreatment of recurrent intracranial vertebral artery dissecting aneurysms (VADAs after stent assisted coiling (SAC has not yet been studied. The purpose of this study was to evaluate the strategies and outcomes for retreatment of recurrent VADAs after SAC.Between September 2009 and November 2013, six consecutive patients presenting with recurrent intracranial VADAs after SAC were enrolled in this study. They were all male with age ranging from 29 to 54 years (mean age, 46.2 years. The procedures of treatments and angiographic and clinical follow-up were reviewed retrospectively. Retreatment modalities were selected individually according to the characteristics of recurrence. The outcomes of retreatment were evaluated by angiographic and clinical follow-up.Six patients with recurrent intracranial VADAs after SAC were retreated, with second SAC in three patients, coil embolization, double overlapping stents placement and endovascular occlusion with aneurysm trapping in one patient, respectively. Immediate angiographic outcomes of retreatment were: complete occlusion in three patients, nearly complete occlusion in two patients, and contrast medium retention in dissecting aneurysm in one patient. All cases were technically successful. No complications related to endovascular procedures occurred. Angiographic follow-up was available in all five patients treated with second SAC or double overlapping stents, which was complete occlusion in four patients, obliteration of parent artery in one patient, showing no recurrence at 4-11 months (mean: 8.6 months. Clinical follow-up was performed in all six patients at 11-51 months after initial endovascular treatment and at 9-43 months after retreatment. The mRS of last clinical follow-up was excellent in five patients and mild disability in only one patient.Endovascular retreatment is feasible and effective for recurrent intracranial VADAs after SAC. Individualized strategies of retreatment should be

  6. Unruptured Brain Aneurysms

    Science.gov (United States)

    ... treated with either endovascular coiling or open surgical clipping. However, if the unruptured aneurysm is treated successfully, ... Medical Advisory Board Publications BAF Newsletters Annual Reports News Public Service Announcements Press Releases Blog Administrative Tax ...

  7. Long term follow-up of bifurcation aneurysms treated with braided stent assisted coiling and complex T- and Y- stent constructs.

    Science.gov (United States)

    Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew; Wenderoth, Jason D

    2018-06-01

    Stent assisted coil embolization (SACE) of bifurcation aneurysms is challenging. Heterogeneous results have been achieved to date, but largely for laser cut stents. While braided stents offer multiple technical advantages, their long term efficacy has yet to be validated. To report the first long term 18 month results for the durability of bifurcation aneurysms treated with braided stents. Over a 4 year period, 59 consecutive patients with 60 bifurcation aneurysms underwent elective braided SACE across three Australian neurovascular centers. 17 of these aneurysms underwent T- or Y-shaped stent constructs. All patients had immediate, 6 month and 18 month clinical and radiological follow-up. Radiological assessment was made on modified Raymond-Roy occlusion scores while clinical assessment was based on the modified Rankin Scale. Subgroup analysis of 17 aneurysms treated with multi-stent constructs was conducted. 6 month follow-up data were available for 59 aneurysms and 18 month follow-up data for 58 aneurysms. Satisfactory aneurysm occlusion was achieved in 97% at inception and at 6 months, and 98% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Similar satisfactory results were achieved with the multi-stent construct cohort. Intraprocedural thromboembolic events were recorded in 5% and delayed events in 2%. Technical complications were found in 5%. All complication rate was 13%. Braided SACE was safe, efficacious, and durable at the long term 18 month follow-up, including for multi-stent constructs. Preliminary results indicate favorable clinical and radiological outcomes compared with laser cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Parent artery occlusion for ruptured "true" posterior communicating artery aneurysm.

    Science.gov (United States)

    Mitsuhashi, Takashi; Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-04-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA

    International Nuclear Information System (INIS)

    Ramgren, Birgitta; Siemund, Roger; Cronqvist, Mats; Undren, Per; Holtaas, Stig; Nilsson, Ola G.; Larsson, Elna-Marie

    2008-01-01

    The purpose of this prospective study was to compare 3T and 1.5T magnetic resonance angiography (MRA) with digital subtraction angiography (DSA) for the follow-up of endovascular treated intracranial aneurysms to assess the grade of occlusion. Thirty-seven patients with 41 aneurysms who had undergone endovascular treatment with detachable coils were included. MRA was performed on the same day using an eight-channel sensitivity encoding head-coil with 3D axial inflow technique. At 3T, a contrast-enhanced transverse 3D fast gradient echo acquisition was also performed. Most patients underwent DSA the following day. MRA scans and DSA were classified first independently by two neuroradiologists and an interventional neuroradiologist. Secondly, a consensus was done. Source images, maximum intensity projection, multiplanar reconstruction and volume rendering reconstructions were used for MRA evaluations. A modification of the Raymond classification, previously used for DSA evaluation of recanalization, was used. Statistical comparison of the consensus showed that 3T MRA with 3D axial inflow technique had better agreement with DSA (κ = 0.43) than 1.5T MRA(κ = 0.21) and contrast-enhanced MRA (CE-MRA) at 3T (κ = 0.17). The susceptibility artefacts from the coil mesh were significally smaller at 3T (p = 0.002-0.007) than at 1.5T. 3T MRA, using a sensitivity encoding head-coil, showed better agreement with DSA than 1.5T and CE-MRA at 3T for evaluation of aneurysms treated with endovascular coiling. (orig.)

  10. Feasibility of Using Intravascular Ultrasonography for Assessment of Giant Cavernous Aneurysm after Endovascular Treatment: A Technical Report

    Science.gov (United States)

    Majidi, Shahram; Grigoryan, Mikayel; Tekle, Wondwossen G; Watanabe, Masaki; Qureshi, Adnan I

    2012-01-01

    Introduction Intravascular ultrasonography (IVUS) has been shown as a valuable adjunct imaging tool during endovascular procedures but its value in detection of any recurrence during follow up after endovascular coil embolization of large and giant intracranial aneurysms is not reported. Methods A 41 years old man who had been treated using stent assisted coil embolization for cavernous segment aneurysm of the left internal carotid artery underwent 60 month angiographic follow up. Concurrently, IVUS catheter was advanced under fluoroscopic guidance inside the cavernous portion of the left internal carotid artery. Then IVUS images were used to visualize the stent, coil loops, and aneurysm neck. Results The angiographic images were limited because of superimposition of the aneurysm on the parent vessel in all projections. IVUS images demonstrated that the stent was patent along its whole length and there was no sign of stent deformity or in-stent thrombosis. Loops of the coil were visualized as hyperechoic signals inside the aneurysm and there was no sign of herniated loops of coil inside the stent. Conclusion In this case report, we observed that adjunct use of IVUS can provide valuable information not ascertained by angiography during follow up assessment of coil embolized aneurysm. PMID:22737259

  11. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  12. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  13. Follow-up of cerebral aneurysm embolization with hydrogel embolic system: Systematic review and meta-analysis.

    Science.gov (United States)

    Serafin, Zbigniew; Di Leo, Giovanni; Pałys, Alicja; Nowaczewska, Magdalena; Beuth, Wojciech; Sardanelli, Francesco

    2015-10-01

    Hydrogel embolic system (HES) for endovascular treatment of cerebral aneurysms was developed to reduce the risk of aneurysm recurrence and the rate of retreatment. The aim of this systematic review was to verify the efficacy of HES, also in comparison to bare platinum coils (BPC). A systematic literature search was performed by two independent reviewers for articles published until January 31st, 2013 on the follow-up recurrence rate of intracranial aneurysm embolization with hydrogel-coated coils. Thirteen articles on the use of HES for embolization of cerebral aneurysms were included in this study, for a total of 1683 embolized aneurysms. Significant heterogeneity was found regarding patient populations, methods of aneurysm coiling, follow-up schedules, and recurrence definitions. The pooled rate of initial complete aneurysm occlusion was 55% (95%CI, 38-70%); 59% (95%CI, 43-74%) in the subgroup of aneurysms treated with the use of HES. The pooled total recurrence rate was 19% (95%CI, 15-24%); 17% (95%CI, 14-22%) in the HES-treated subgroup. The pooled major recurrence rate was 12% (95%CI, 8-18%); 11% (95%CI, 7-16%) in the HES-treated subgroup. Comparing both types of coils, the pooled odds ratio for total recurrence was 0.63 (95%CI, 0.45-0.88; p=0.008) in favor of HES. Embolization of cerebral aneurysms using HES seems to result in a lower rate of recurrence than that obtained using BPC, which is in line with the only randomized controlled trial. High-quality prospective studies are needed to define specific indications for the use of hydrogel-coated coils. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Clinical value of virtual three-dimensional instrument and cerebral aneurysm models in the interventional preoperative simulation

    International Nuclear Information System (INIS)

    Wei Xin; Xie Xiaodong; Wang Chaohua

    2007-01-01

    Objective: To establish virtual three-dimensional instrument and cerebral aneurysm models by using three-dimensional moulding software, and to explore the effect of the models in interventional preoperative simulation. Methods: The virtual individual models including cerebral arteries and aneurysms were established by using the three-dimensional moulding software of 3D Studio MAX R3 based on standard virtual cerebral aneurysm models and individual DSA image. The virtual catheter, guide wire, stent and coil were also established. The study of interventional preoperative simulation was run in personal computer, and included 3 clinical cases. Results: The simulation results of the working angle and the moulding angle of the head of catheter and guide wire in 3 cases were identical with that of operation results. The simulation results of the requirement of number and size of coil in 1 case of anterior communicating aneurysm and 1 case of posterior communicating aneurysm were identical with that of operation results. The simulation results of coil for aneurysmal shape in 1 case of giant internal carotid artery aneurysm were more than 2 three-dimensional coils with size of 3 mm x 3 cm from the operation results, and the position of the second coil in aneurysmal neck was adjusted according to the results of real-time simulation. The results of retrospective simulation of operation procedure indicated that the simulation methods for regular and small aneurysms could become a routine simulation means but more simulation experience was needed to build up for the giant aneurysms. Conclusions: The virtual three-dimensional instrument and cerebral aneurysm models established by the general software provided a new study method for neuro-interventional preoperative simulation, and it played an important guidance role in developing neuro-interventional operation. (authors)

  15. A novel flow diverter(Tubridge) for the treatment of recurrent aneurysms: A single-center experience

    International Nuclear Information System (INIS)

    Zhang, Yong Xin; Huang, Qing Hai; Fang, Yibin; Yang, Peng Fei; Xu, Yi; Hong Bo; Liu, Jian Min

    2017-01-01

    The Tubridge flow diverter (FD) is a novel device aimed at reconstructing the parent artery and occluding complex aneurysms. Retreatment of recurrent aneurysms using the FD is challenging. We report our initial experience in the repair of aneurysm recurrence with the FD. A database was reviewed prospectively, and 8 patients with 8 recurrent aneurysms (mean size, 16.7 mm) were identified. Four aneurysms had previously ruptured. The previous aneurysm treatment consisted of coiling in 1 aneurysm and single-stent-assisted coiling in 7 aneurysms. The procedural complications and clinical and angiographic outcomes were analyzed. Six aneurysms were treated by using a single Tubridge FD alone, while the remaining 2 were treated with FD + coiling. The immediate results of the 8 aneurysms were that they all showed incomplete occlusion. Neither major ischemic nor hemorrhagic complications occurred; however, 1 patient experienced a vasospasm. Follow-up angiographies were available for 7 aneurysms; the mean follow-up was 16.9 months (7–36 months). Five aneurysms were completely occluded, whereas 2 had a residual neck. Severe asymptomatic stenosis of 1 parent artery of a vertebral artery dissecting aneurysm was found. All visible branches covered by the FD were patent. All patients were clinically assessed as having attained a favorable outcome (modified Rankin Scale score ≤ 2) at discharge and follow-up. In selected patients, the Tubridge FD can provide a safe and efficient option for the retreatment of recurrent aneurysms. Nevertheless, attention should be paid to several technical points

  16. A novel flow diverter(Tubridge) for the treatment of recurrent aneurysms: A single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yong Xin; Huang, Qing Hai; Fang, Yibin; Yang, Peng Fei; Xu, Yi; Hong Bo; Liu, Jian Min [Dept. of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai (China)

    2017-09-15

    The Tubridge flow diverter (FD) is a novel device aimed at reconstructing the parent artery and occluding complex aneurysms. Retreatment of recurrent aneurysms using the FD is challenging. We report our initial experience in the repair of aneurysm recurrence with the FD. A database was reviewed prospectively, and 8 patients with 8 recurrent aneurysms (mean size, 16.7 mm) were identified. Four aneurysms had previously ruptured. The previous aneurysm treatment consisted of coiling in 1 aneurysm and single-stent-assisted coiling in 7 aneurysms. The procedural complications and clinical and angiographic outcomes were analyzed. Six aneurysms were treated by using a single Tubridge FD alone, while the remaining 2 were treated with FD + coiling. The immediate results of the 8 aneurysms were that they all showed incomplete occlusion. Neither major ischemic nor hemorrhagic complications occurred; however, 1 patient experienced a vasospasm. Follow-up angiographies were available for 7 aneurysms; the mean follow-up was 16.9 months (7–36 months). Five aneurysms were completely occluded, whereas 2 had a residual neck. Severe asymptomatic stenosis of 1 parent artery of a vertebral artery dissecting aneurysm was found. All visible branches covered by the FD were patent. All patients were clinically assessed as having attained a favorable outcome (modified Rankin Scale score ≤ 2) at discharge and follow-up. In selected patients, the Tubridge FD can provide a safe and efficient option for the retreatment of recurrent aneurysms. Nevertheless, attention should be paid to several technical points.

  17. In vitro simulator with numerical stress analysis for evaluation of stent-assisted coiling embolization in cerebral aneurysm treatments.

    Science.gov (United States)

    Shi, Chaoyang; Kojima, Masahiro; Tercero, Carlos; Najdovski, Zoran; Ikeda, Seiichi; Fukuda, Toshio; Arai, Fumihito; Negoro, Makoto

    2014-12-01

    There are several complications associated with Stent-assisted Coil Embolization (SACE) in cerebral aneurysm treatments, due to damaging operations by surgeons and undesirable mechanical properties of stents. Therefore, it is necessary to develop an in vitro simulator that provides both training and research for evaluating the mechanical properties of stents. A new in vitro simulator for three-dimensional digital subtraction angiography was constructed, followed by aneurysm models fabricated with new materials. Next, this platform was used to provide training and to conduct photoelastic stress analysis to evaluate the SACE technique. The average interaction stress increasingly varied for the two different stents. Improvements for the Maximum-Likelihood Expectation-Maximization method were developed to reconstruct cross-sections with both thickness and stress information. The technique presented can improve a surgeon's skills and quantify the performance of stents to improve mechanical design and classification. This method can contribute to three-dimensional stress and volume variation evaluation and assess a surgeon's skills. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Enterprise Deployment Through PulseRider To Treat Anterior Communicating Artery Aneurysm Recurrence.

    Science.gov (United States)

    Valente, Iacopo; Limbucci, Nicola; Nappini, Sergio; Rosi, Andrea; Laiso, Antonio; Mangiafico, Salvatore

    2018-02-01

    PulseRider (Pulsar Vascular, Los Gatos, California, USA) is a new endovascular device designed to treat wide-neck bifurcation intracranial aneurysms. Deployment of a stent through a PulseRider to treat an aneurysm's recurrence has never been described before. We report the case of a 55-year-old man who underwent coiling of an 8-mm anterior communicating artery aneurysm with assistance of a PulseRider neck reconstruction device. The 6-month digital subtraction angiography control showed aneurysm recurrence, so we deployed an Enterprise 2 closed-cell stent (Codman, Miami Lakes, Florida, USA) in the A1-A2 segment passing across the previously implanted PulseRider. Enterprise correctly expanded and allowed for adequate coiling of the aneurysm. An Enterprise stent can be safely opened through a PulseRider in order to treat aneurysm recurrence. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Monorail snare technique for the recovery of stretched platinum coils: technical case report.

    Science.gov (United States)

    Fiorella, David; Albuquerque, Felipe C; Deshmukh, Vivek R; McDougall, Cameron G

    2005-07-01

    Coil stretching represents a potentially hazardous technical complication not infrequently encountered during the embolization of cerebral aneurysms. Often, the stretched coil cannot be advanced into the aneurysm or withdrawn intact. The operator is then forced to attempt to retract the damaged coil, which may result in coil breakage, leaving behind a significant length of potentially thrombogenic stretched coil material within the parent vessel. To overcome this problem, we devised a technique to snare the distal, unstretched, intact portion of the platinum coil by use of the indwelling microcatheter and stretched portion of the coil as a monorail guide. We have used this technique successfully in four patients to snare coils stretched during cerebral aneurysm embolization. Three of these patients were undergoing Neuroform (Boston Scientific/Target, Fremont, CA) stent-supported coil embolization of unruptured aneurysms. In all cases, the snare was advanced easily to the targeted site for coil engagement by use of the microcatheter as a monorail guide. Once the intact distal segment of the coil was ensnared, coil removal was uneventful, with no disturbance of the remainder of the indwelling coil pack or Neuroform stent. A 2-mm Amplatz Goose Neck microsnare (Microvena Corp., White Bear Lake, MN) was placed through a Prowler-14 microcatheter (Cordis Corp., Miami, FL). The hub of the indwelling SL-10 microcatheter (Boston Scientific, Natick, MA) was then cut away with a scalpel, leaving the coil pusher wire intact, and removed. The open 2-mm snare was then advanced over the outside of the coil pusher wire and microcatheter. The snare and Prowler-14 microcatheter were then advanced into the guiding catheter (6- or 7-French) as a unit over the indwelling SL-10 microcatheter. By use of the SL-10 microcatheter and coil as a "monorail" guide, the snare was advanced over and beyond the microcatheter and the stretched portion of the coil until the snare was in position to

  20. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    Science.gov (United States)

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  1. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  2. Angiographic and artefact-free computed tomography imaging of experimental aneurysms embolised with hydrogel filaments

    Energy Technology Data Exchange (ETDEWEB)

    McCoy, Mark R. [Paracelsus Medical University, Department of Radiology and Magnetic Resonance Tomography, Christian Doppler Clinic, Salzburg (Austria); Cruise, Gregory M. [MicroVention Terumo, Aliso Viejo, CA (United States); Killer, Monika [Paracelsus Medical University, Department of Neurology/Neuroscience Institute, Christian Doppler Clinic, Salzburg (Austria)

    2010-04-15

    We compared experimental rabbit carotid bifurcation aneurysms embolised with platinum coils or hydrogel filaments by using digital subtraction angiography (DSA) and computed tomography angiography (CTA). Embolisation was performed using platinum coils (n = 2), hydrogel filaments loaded with iodine (n = 3) and hydrogel filaments loaded with barium sulphate (n = 3). In one case, a stent was deployed in the parent vessel to determine the effect of hydrogel filaments on stent visualisation. DSA evaluations occurred immediately post-treatment. CTA evaluations occurred at 0-13 weeks post-treatment. The DSA and CTA images were evaluated for the lack of artefacts and the visibilities of the embolic mass, individual coils and residual flow in the aneurysm sac and neck. The DSA results were largely concordant among the three groups. The embolic masses were readily evident with some individual coils being distinguished. In the aneurysms embolised with hydrogel filaments, visualisation of the individual coils, residual flow and stent with minor or no artefacts was possible using CTA. On the other hand, the beam hardening artefacts precluded analysis of aneurysms embolised with platinum coils. CTA-compatible embolic devices could have wide applications in diverse locations throughout the vasculature, particularly in combination with stents or stent grafts. (orig.)

  3. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Schaafsma, Joanna D., E-mail: j.d.schaafsma@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Velthuis, Birgitta K., E-mail: b.k.velthuis@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: koen@isi.uu.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Kort, Gerard A.P. de, E-mail: g.a.p.dekort@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Rinkel, Gabriel J.E., E-mail: g.j.e.rinkel@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Bartels, Lambertus W., E-mail: w.bartels@umcutrecht.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands)

    2014-05-15

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths.

  4. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    International Nuclear Information System (INIS)

    Schaafsma, Joanna D.; Velthuis, Birgitta K.; Vincken, Koen L.; Kort, Gerard A.P. de; Rinkel, Gabriel J.E.; Bartels, Lambertus W.

    2014-01-01

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths

  5. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography--An in vivo and in vitro study.

    Science.gov (United States)

    Schaafsma, Joanna D; Velthuis, Birgitta K; Vincken, Koen L; de Kort, Gerard A P; Rinkel, Gabriel J E; Bartels, Lambertus W

    2014-05-01

    To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0Tesla. We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Coil artefacts disturbed assessments less frequently at 3.0Tesla than at 1.5Tesla (RR: 0.3; 95%CI: 0.1-0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7mm; 95%CI: 0.3-1.1) and larger than on IA-DSA (difference: 1.0mm; 95%CI: 0.6-1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23-0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19-0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0Tesla than at 1.5Tesla. The echo-time influenced artefact size more than the read-out gradient. Artefacts were not larger, but smaller at 3.0Tesla because a shorter echo-time at 3.0Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0Tesla, occlusion levels were similar for both field strengths. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Su, I. Chang; Willinsky, Robert A.; Agid, Ronit; Fanning, Noel F.

    2014-01-01

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development. We performed a retrospective analysis of consecutively treated unruptured aneurysms between January 2000 and December 2011. The presence and evolution of wall enhancement and perianeurysmal edema on MRI after endovascular treatment were analyzed. Variable factors were compared among aneurysms with and without edema. One hundred thirty-two unruptured aneurysms in 124 patients underwent endovascular treatment. Eighty-five (64.4 %) aneurysms had wall enhancement, and 9 (6.8 %) aneurysms had perianeurysmal brain edema. Wall enhancement tends to persist for years with two patterns identified. Larger aneurysms and brain-embedded aneurysms were significantly associated with wall enhancement. In all edema cases, the aneurysms were embedded within the brain and had wall enhancement. Progressive thickening of wall enhancement was significantly associated with edema. Edema can be symptomatic when in eloquent brain and stabilizes or resolves over the years. Our study demonstrates the prevalence and some appreciation of the natural history of aneurysmal wall enhancement and perianeurysmal brain edema following endovascular treatment of unruptured aneurysms. Aneurysmal wall enhancement is a common phenomenon while perianeurysmal edema is rare. These phenomena are likely related to the presence of inflammatory reaction near the aneurysmal wall. Both phenomena are usually asymptomatic and self-limited, and prophylactic treatment is not recommended. (orig.)

  7. Endovascular treatment of basilar tip aneurysms associated with moyamoya disease

    International Nuclear Information System (INIS)

    Arita, K.; Kurisu, K.; Ohba, S.; Shibukawa, M.; Kiura, H.; Sakamoto, S.; Uozumi, T.; Nakahara, T.

    2003-01-01

    We report the efficacy and safety of endovascular treatment of basilar tip aneurysms (BTA) in five patients with moyamoya disease. The patients underwent intra-aneurysmal embolisation with detachable platinum coils. Three BTA presented with subarachnoid haemorrhage (SAH); the other two were asymptomatic. In four cases, one embolisation procedure produced >95% angiographic obliteration of the aneurysm. In the other patient, 80-90% obliteration was achieved initially, but due to growth of the residual aneurysm, the procedure was repeated 7 months later. Two patients experienced transient oculomotor paresis as a procedure-related complication. Mean follow-up was 43.6±34.0 months (range 8-92 months). One patient died of putaminal haemorrhage unrelated to the aneurysm 15 months after embolisation. The other four had no subsequent SAH and survived without sequelae. Endovascular embolisation using detachable platinum coils proved to be a safe and efficient treatment modality for BTA associated with moyamoya disease. (orig.)

  8. Free-boundary Full-pressure Island Healing in a Stellarator: Coil-healing

    International Nuclear Information System (INIS)

    Hudson, S.R.; Reiman, A.; Strickler, D.; Brooks, A.; Monticello, D.A.; Hirshman, S.P.

    2002-01-01

    The lack of axisymmetry in stellarators guarantees that in general magnetic islands and chaotic magnetic field lines will exist. As particle transport is strongly tied to the magnetic field lines, magnetic islands and chaotic field lines result in poor plasma confinement. For stellarators to be feasible candidates for fusion power stations it is essential that, to a good approximation, the magnetic field lines lie on nested flux-surfaces, and the suppression of magnetic islands is a critical issue for stellarator coil design, particularly for small aspect ratio devices. A procedure for modifying stellarator coil designs to eliminate magnetic islands in free-boundary full-pressure magnetohydrodynamic equilibria is presented. Islands may be removed from coil-plasma free-boundary equilibria by making small changes to the coil geometry and also by variation of trim coil currents. A plasma and coil design relevant to the National Compact Stellarator Experiment is used to illustrate the technique

  9. Current management of inguinal false aneurysms

    DEFF Research Database (Denmark)

    Houlind, Kim; Jepsen, Jørn M; Saicu, Cristian

    2017-01-01

    False aneurysms are formed as a result of bleeding causing a hematoma to compress the surrounding tissue. The majority of false aneurysms presenting to the vascular surgeon are caused by iatrogenic injury to an artery. Although anastomotic failure occurs, a much higher number is caused by bleeding...... vessels. endovascular treatment with coils or covered stent grafts have proven useful in infected ilio-femoral false aneurysms. Open surgical repair may be the best treatment in the setting of imminent rupture, massive haematoma and skin necrosis. We present three patient cases treated with open surgery...

  10. Surgical clipping as the preferred treatment for aneurysms of the middle cerebral artery

    NARCIS (Netherlands)

    van Dijk, J. Marc C.; Groen, Rob J. M.; Ter Laan, Mark; Jeltema, Johanna Rinck; Mooij, Jan Jacob A.; Metzemaekers, Jan D. M.

    2011-01-01

    In recent years the endovascular treatment of intracranial aneurysms (coiling) has progressively gained recognition, particularly after the publication of the International Subarachnoid Aneurysm Trial (ISAT) in 2002. Despite the fact that in ISAT middle cerebral artery (MCA) aneurysms were clearly

  11. Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Yang Zhigang; Liu Jianmin; Xu Yi; Huang Qinghai; Hong Bo; Zhao Wenyuan; Zhao Rui

    2008-01-01

    Objective: To assess the value of a novel retrievable self-expanding stent system (LEO) in intracranial aneurysm treatment. Methods: 43 patients with 44 intracranial aneurysms treated with LEO stent were retrospectively analized, including 16 aneurysms with single-stent deployment, 25 with stent-assisted technique, 2 with double-stent deployment and one with double-stent assisted coils. Follow up was carried out through imaging and clinical course. Results: The stent was easy for repositioning and all the stents were delivered successfully, except 1 stent with unsatisfactory position, 1 with acute in-stent thrombosis. During follow up, 1 case showed chronic in-stent thrombus and one with intimal hyperplasia. 22 aneurysms got compact coiled during procedure. Among 29 follow up cases, 72.4% aneurysms were cured or improved, 13.8% were stable and three dissection aneurysms enlarged within short period and two patients died. Conclusion: The new retrievable self-expanding stent (LEO), with the advantages of controlled delivery, easy deployment and choice for various types is a valuable system for vascular reconstruction of intracranial aneurysm with thrombosis. (authors)

  12. Endovascular treatment of radiation-induced petrous internal carotid artery aneurysm presenting with acute haemorrhage. A report of two cases

    International Nuclear Information System (INIS)

    Cheng, K.-M.; Chiu, H.-M.; Chan, C.-M.; Cheung, Y.-L.; Tang, K.-W.; Law, C.-K.

    2001-01-01

    Hemorrhage from rupture of petrous ICA aneurysm can be life threatening and emergency treatment is required. We report 2 cases of radiation-induced petrous internal carotid artery (ICA) aneurysm presenting with acute hemorrhage (epistaxis and otorrhagia) after radiotherapy (RT) for nasopharyngeal carcinoma (NPC). Both patients had a history of RT treatment for NPC. The first patient, a 54-year-old man, presented with sudden severe epistaxis and hemorrhagic shock. The second patient, a 35-year-old man, presented with episodes of severe otorrhagia. The first patient was immediately resuscitated. Obliteration of the aneurysm was performed by endovascular occlusion of the ICA with Guglielmi detachable coils and fibered platinum coils. For the second patient, the aneurysm was treated by deploying a self-expandable stent across the aneurysm neck. In an emergency situation, ruptured petrous ICA aneurysm can be treated with endovascular occlusion of the ICA with micro-coils if there is a good collateral blood flow. Alternatively, the aneurysm can be treated by deployment of a stent, which can induce stasis and eventual thrombosis of the aneurysm. (author)

  13. A novel intracranial enterprise stent together with colis for the treatment of very small intracranial wide-necked aneurysms

    International Nuclear Information System (INIS)

    Huang Haidong; Zhao Kai; Gu Jianwen; Qu Yan; Yang Tao; Xia Xun; Lin Long; Zhang Hui

    2010-01-01

    Objective: To make a preliminary investigation and summary of the technique and efficacy of the novel intracranial stent, Enterprise, together with hydro-detachable coils for the treatment of very small intracranial wide-necked aneurysms (diameter < 3 mm and body-to-neck ratio < 1.5). Methods: Six cases with very small intracranial wide-necked aneurysms were treated with Enterprise stents and hydrodetachable coils. In 5 cases the Enterprise stent was implanted to cover the neck of the aneurysm, which was followed by the introduction of a microcatheter into the aneurysmal sac through the stent mesh to stuff hydrodetachable coils in order to fill the aneurysmal sac. In the remaining case, the microcatheter was placed into the aneurysmal sac before the Enterprise stent was inserted to embolize the aneurysm. Postoperative follow-up was conducted for 3-6 months. Results: The operation was successfully completed in all 6 patients, with the implanted stents being in right place. The parent arteries remained patency in all patients. No complications occurred. Complete occlusion of aneurysmal cavity was obtained in four cases, and the occlusion degree of the aneurysmal cavity above 95% was seen in 2 cases. After the procedure, all the patients recovered well. Neither rebleeding nor symptoms related to thrombosis occurred during a clinic followup of 3-6 months. Conclusion: Endovascular embolization with Enterprise stent together with hydrodetachable coils is a safe and effective method for the treatment of very small intracranial wide-necked aneurysms.However, its long-term effect needs to be further observed. (authors)

  14. Symptomatic unruptured cerebral aneurysms. Features and surgical outcome

    International Nuclear Information System (INIS)

    Date, Isao

    2010-01-01

    Development of less invasive imaging studies, such as magnetic resonance angiography, has increased the chances that unruptured cerebral aneurysms are found. The rupture risk of 'symptomatic' aneurysms is higher than for 'asymptomatic' aneurysms; so 'symptomatic' aneurysms are more often surgically treated. Many reviews examine 'asymptomatic' unruptured cerebral aneurysms, but few evaluate 'symptomatic' aneurysms. The author has treated many patients with symptomatic unruptured cerebral aneurysms and found that improved cranial nerve signs can be expected if the surgical treatment is performed before the symptoms become irreversible; the critical period is approximately 3 months. It is important to suppress the pulsation of the aneurysms compressing the cranial nerves; both a clipping procedure and endovascular coiling are effective. Cranial nerve signs are more commonly the symptoms of unruptured cerebral aneurysms, but large to giant aneurysms can also be the causes of hemiparesis, hydrocephalus, epilepsy, or even cerebral infarction. This review summarizes the features and surgical outcome of symptomatic unruptured cerebral aneurysms. (author)

  15. To wait for a spontaneous recovery of the third cranial nerve palsy occurring after the coiling of a PcomA aneurysm or to implement surgical treatment? A case report

    Directory of Open Access Journals (Sweden)

    Peulić Miodrag

    2017-01-01

    Full Text Available Introduction. In the last two decades a method of endovascular embolization has been imposed as a method of choice in the treatment of unruptured intracranial aneurysms. Therefore, the problem of treating posterior communicating artery (PComA aneurysms presenting with the third cranial nerve (TCN palsy has become even more complex. The case of a patient reported in the paper itself has presented a dilemma of whether to wait for spontaneous resolution of ophthalmoplegia developed after the coiling of a PComA aneurysm or whether to implement an early surgical treatment. Case report. An unruptured saccular aneurysm, directed inferolaterally in the right internal carotid artery (ICA segment in the position of the PcomA origin, was diagnosed in a 58-year-old male patient. The aneurysm was measuring 9 mm in diameter while the neck was measuring 5 mm. The day before the planned embolization, the patient developed ipsilateral ophthalmoparesis, whereas the first day after the endovascular procedure was completed, the patient developed right-sided complete ophthalmoplegia. Ten weeks after the endovascular embolization our team decided to perform a microsurgical treatment including aneurysm clipping and coil extraction. Eighteen months after the surgery, the patient made a full recovery of the functions of musculus (m levator palpabrae, m. rectus medialis and pupillary function, with a partial recovery of the functions of m. obliqus inferior, m. rectus inferior and m. rectus superior. Conclusion. According to medical research and literature, the partial recovery of the TCN palsy is expected to happen in the first few weeks after embolization. Despite the completion of endovascular treatment progression of ophthalmoparesis to ophthalmoplegia without any simptoms of clinical improvement after 10 weeks is considered to be an indicator of longstanding TCN compression, which can lead to irreversible nerve damage. Despite the increase in the use of an

  16. Safety and efficacy of aneurysm treatment with WEB

    DEFF Research Database (Denmark)

    Pierot, Laurent; Costalat, Vincent; Moret, Jacques

    2016-01-01

    OBJECT WEB is an innovative intrasaccular treatment for intracranial aneurysms. Preliminary series have shown good safety and efficacy. The WEB Clinical Assessment of Intrasaccular Aneurysm Therapy (WEBCAST) trial is a prospective European trial evaluating the safety and efficacy of WEB in wide......-neck bifurcation aneurysms. METHODS Patients with wide-neck bifurcation aneurysms for which WEB treatment was indicated were included in this multicentergood clinical practices study. Clinical data including adverse events and clinical status at 1 and 6 months were collected and independently analyzed by a medical....... RESULTS Ten European neurointerventional centers enrolled 51 patients with 51 aneurysms. Treatment with WEB was achieved in 48 of 51 aneurysms (94.1%). Adjunctive implants (coils/stents) were used in 4 of 48 aneurysms (8.3%). Thromboembolic events were observed in 9 of 51 patients (17.6%), resulting...

  17. Intracranial aneurysms: optimized diagnostic tools call for thorough interdisciplinary treatment strategies.

    Science.gov (United States)

    Mueller, Oliver M; Schlamann, Marc; Mueller, Daniela; Sandalcioglu, I Erol; Forsting, Michael; Sure, Ulrich

    2011-09-01

    Intracranial aneurysms (IAs) require deliberately selected treatment strategies as they are incrementally found prior to rupture and deleterious subarachnoid haemorrhage (SAH). Multiple and recurrent aneurysms necessitate both neurointerventionalists and neurosurgeons to optimize aneurysmal occlusion in an interdisciplinary effort. The present study was conducted to condense essential strategies from a single neurovascular centre with regard to the lessons learned. Medical charts of 321 consecutive patients treated for IAs at our centre from September 2008 until December 2010 were retrospectively analysed for clinical presentation of the aneurysms, multiplicity and treatment pathways. In addition, a selective Medline search was performed. A total of 321 patients with 492 aneurysms underwent occlusion of their symptomatic aneurysm: 132 (41.1%) individuals were treated surgically, 189 (58.2%) interventionally; 138 patients presented with a SAH, of these 44.2% were clipped and 55.8% were coiled. Aneurysms of the middle cerebral artery were primarily occluded surgically (88), whereas most of the aneurysms of the internal carotid artery and anterior communicating artery (114) were treated endovascularly. Multiple aneurysms (range 2-5 aneurysms/individual) were diagnosed in 98 patients (30.2%). During the study period 12 patients with recurrent aneurysms were allocated to another treatment modality (previously clip to coil and vice versa). Our data show that successful interdisciplinary occlusion of IAs is based on both neurosurgical and neurointerventional therapy. In particular, multiple and recurrent aneurysms require tailored individual approaches to aneurysmal occlusion. This is achieved by a consequent interdisciplinary pondering of the optimal strategy to occlude IAs in order to prevent SAH.

  18. Tuberothalamic Artery Infarction Following Coil Embolization of a Ruptured Posterior Communicating Artery Aneurysm Belonging to a Transitional Type Posterior Cerebral Artery

    Science.gov (United States)

    Lee, Kyeong Duk; Kwon, Soon Chan; Muniandy, Sarawana; Park, Eun Suk; Sim, Hong Bo; Lyo, In Uk

    2013-01-01

    Summary There are many potential anatomical variations in the connection between the internal carotid artery and the posterior circulation through the posterior communicating artery (PCoA). We describe the endovascular treatment of an aneurysm arising near the origin of the PCoA belonging to a transitional type posterior cerebral artery. Coil embolization subsequently resulted in thrombo-occlusion of the adjacent PCoA causing thalamic infarction even though sufficient retrograde flow had been confirmed pre-operatively by Allcock’s test. PMID:24070079

  19. Clinical outcome after endovascular coil embolization in elderly patients with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Johansson, M.; Cesarini, K.G.; Ronne-Engstroem, E.; Enblad, P.; Norbaeck, O.; Gal, G.; Tovi, M.; Solander, S.; Contant, C.F.

    2004-01-01

    Subarachnoid hemorrhage (SAH) is not an unusual disease in an elderly population. The clinical outcome has improved over time. It has been suggested that elderly SAH patients would benefit from endovascular aneurysm treatment. The aim of this study was to evaluate technical results and clinical outcome in a series of elderly SAH-patients treated with endovascular coil embolization. Sixty-two patients (≥ 65 years) presenting with aneurysmal SAH underwent early endovascular coil embolization at Uppsala University Hospital between September 1996 and December 2000. In all 62 cases included in the study, endovascular coil embolization was considered the first line of treatment. Admission variables, specific information on technical success, degree of occlusion and procedural complications, and outcome figures were recorded. Clinical grade on admission was Hunt and Hess (H and H) I-II in 39%, H and H III in 27% and H and H IV-V in 34% of the patients. The proportion of posterior circulation aneurysms was 24%. Coil embolization was successfully completed in 94%. The degree of occlusion of the treated aneurysm was complete occlusion in 56%, neck remnant in 21%, residual filling in 11%, other remnant in 5% and not treated in 6%. The rate of procedural complications was 11%. Outcome after 6 months was favorable in 41%, severe disability in 36% and poor in 22%. Favorable outcome was achieved in 57% of the H and H I-II patients, 47% of the H and H III patients and 17% of the H and H IV-V patients. Endovascular aneurysm treatment can be performed in elderly patients with SAH with a high level of technical success, acceptable aneurysm occlusion results, an acceptable rate of procedural complications and fair outcome results. (orig.)

  20. The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy

    International Nuclear Information System (INIS)

    Moehlenbruch, M.; Herweh, C.; Behrens, L.; Jestaedt, L.; Bendszus, M.; Pham, M.; Amiri, H.; Ringleb, P.A.

    2014-01-01

    This study was aimed to assess clinical safety and efficacy of the LVIS Jr. microstent in stent-assisted coil embolization of wide-neck intracranial aneurysms. IRB approved single-center interventional clinical study in 22 patients (10 females, 12 males, mean age 55, age range 33-74 years) for the endovascular treatment of wide-neck aneurysms. After obtaining informed consent, patients were included according to the following criteria: aneurysm fundus-to-neck ratio 4 mm, and a parent vessel diameter of ≤3.5 mm. Primary end point for clinical safety was absence of death, absence of major or minor stroke, and absence of transient ischemic attack. Primary end point for treatment efficacy was complete angiographic occlusion according to the Raymond-Roy Occlusion Classification (RROC) immediately after the procedure and at follow-up after 3 and 6 months on magnetic resonance imaging (MRI). In 20/22 (91 %) of patients, the primary end point of safety was reached; in the two remaining patients, transient ischemic attack, but no permanent deficit was observed; in 16/22 (73 %), efficient occlusion (RROC1) was reached, and in 6/22 (27 %), a residual neck remained (RROC2). Single [seven with antegrade, two in crossover configuration, and four with ''first-balloon-then-stent'' (FBTS) technique] or double-stent (eight patients with Y configuration and one patient with X configuration) deployment was technically successful in all cases. Deployment of the LVIS Jr. microstent in various single- or double-stent configurations is safe and effective to assist the treatment of intracranial wide-neck aneurysms. (orig.)

  1. Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

    Science.gov (United States)

    Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-04-01

    Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location. We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type. After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.

  2. Embolization of Brain Aneurysms and Fistulas

    Science.gov (United States)

    ... care physician. top of page What are the benefits vs. risks? Benefits Using detachable coils to close off an aneurysm ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  3. Enterprise stent-assisted coiling for wide-necked intracranial aneurysms during ultra-early (48hours) subarachnoid hemorrhage: a single-center experience in 59 consecutive patients.

    Science.gov (United States)

    Liu, Aihua; Peng, Tangming; Qian, Zenghui; Li, Youxiang; Jiang, Chuhan; Wu, Zhongxue; Yang, Xinjian

    2015-10-01

    Accumulated experience and improvement of stents dedicated to intracranial use have significantly widened the applicability of stent-assisted coiling (SAC) to ruptured wide-necked aneurysms. This retrospective study was designed to evaluate the safety and efficacy of SAC using the Enterprise stent for ruptured wide-necked intracranial aneurysms during ultra-early subarachnoid hemorrhage. We reviewed data from 59 consecutive patients with ruptured wide-necked aneurysms who had SAC using the Enterprise stent performed within 48hours of onset. Data collected and analyzed included: patient demographics; morphologic features of the aneurysm; treatment results and follow-up results. Clinical outcomes were evaluated by modified Rankin Scale (mRS). In all 59 cases, SAC using the Enterprise stent was performed successfully, with no significant technical difficulties. Initial angiographic results were: complete occlusion in 38 cases; near occlusion in 17; and partial occlusion in four. Angiographic follow-up of 48 patients showed that 46 (95.8%) remained stable or improved, without regrowth, while regrowth was imaged in two patients. Medium-term clinical follow-up of 54 patients (mean, 26.9months) showed that 88.9% had a good outcome (mRS: 0 in 34; 1 in eight; and 2 in six), and 11.1% poor outcomes (mRS: 3 in four; and 4 in two). Enterprise SAC is a safe and viable option for treatment of ruptured wide-necked aneurysms within 48hours of ictus. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  4. Balloon-assisted coiling through a 5-French system

    International Nuclear Information System (INIS)

    White, J. Bradley; Layton, Kennith F.; Kallmes, David F.; Cloft, Harry J.

    2007-01-01

    We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms. A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath. This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging. We conclude that this small-diameter system provides ample ''room'' for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters. (orig.)

  5. Endovascular Management of Fusiform Superior Cerebellar Artery Aneurysms: A Series of Three Cases with Review of Literature

    Directory of Open Access Journals (Sweden)

    Anand Alurkar

    2012-01-01

    Full Text Available Distal superior cerebellar artery (SCA aneurysms are rare. Fusiform aneurysms of SCA are rarer and more challenging to treat. Parent artery occlusion by endovascular coiling is the treatment option for these cases. Presence of good collateral circulation and paucity of perforators from S1 and S2 segments makes this a feasible option. From 2007 to 2010, we treated three patients (two men and one woman between the ages of 42 to 64 years with distal fusiform SCA aneurysms using endovascular coiling. All the patients presented with symptoms of rupture and were treated in the acute phase. Informed and written high-risk consent was given by all patients prior to the procedure. Successful angiographic and clinical outcome was achieved in all three patients. Endovascular treatment of fusiform SCA aneurysms with coils is a safe and feasible option in the management of this rare entity.

  6. Postprocedural Monitoring of Cerebral Aneurysms

    International Nuclear Information System (INIS)

    Kaehaerae, V.

    2006-01-01

    The treatment of intracranial aneurysms has been revolutionized since the introduction of electrolytically detachable platinum coils in 1991. Since this basic innovation, many refinements of the embolic materials and techniques have emerged. Today, in Europe, half of all aneurysms are treated endoarterially and this share is growing. The reassuring results of the International Subarachnoid Aneurysm Trial (ISAT) have changed the treatment strategy from neurosurgical clipping to embolization. However, the role of these alternative modes of treatment varies between institutions and countries. An angiographic follow-up pattern after endovascular treatment has remained largely undefined and in the same way there has been much diversity in applying alternative imaging modalities. Although some institutions continue to perform intervalled digital subtraction angiography, magnetic resonance angiography has assumed an increasing role. A vast majority of patients with embolized aneurysms are eligible to be monitored solely by non-contrast three-dimensional time-of-flight technique

  7. Tuberothalamic Artery Infarction Following Coil Embolization of a Ruptured Posterior Communicating Artery Aneurysm Belonging to a Transitional Type Posterior Cerebral Artery: A Case Report

    OpenAIRE

    Lee, Kyeong Duk; Kwon, Soon Chan; Muniandy, Sarawana; Park, Eun Suk; Sim, Hong Bo; Lyo, In Uk

    2013-01-01

    There are many potential anatomical variations in the connection between the internal carotid artery and the posterior circulation through the posterior communicating artery (PCoA). We describe the endovascular treatment of an aneurysm arising near the origin of the PCoA belonging to a transitional type posterior cerebral artery. Coil embolization subsequently resulted in thrombo-occlusion of the adjacent PCoA causing thalamic infarction even though sufficient retrograde flow had been confirm...

  8. Closed-cell stent for coil embolization of intracranial aneurysms: clinical and angiographic results.

    Science.gov (United States)

    Wakhloo, A K; Linfante, I; Silva, C F; Samaniego, E A; Dabus, G; Etezadi, V; Spilberg, G; Gounis, M J

    2012-10-01

    Recanalization is observed in 20-40% of endovascularly treated intracranial aneurysms. To further reduce the recanalization and expand endovascular treatment, we evaluated the safety and efficacy of closed-cell SACE. Between 2007 and 2010, 147 consecutive patients (110 women; mean age, 54 years) presenting at 2 centers with 161 wide-neck ruptured and unruptured aneurysms were treated by using SACE. Inclusion criteria were wide-neck aneurysms (>4 mm or a dome/neck ratio ≤ 2). Clinical outcomes were assessed by the mRS score at baseline, discharge, and follow-up. Aneurysm occlusion was assessed on angiograms by using the RS immediately after SACE and at follow-up. Eighteen aneurysms (11%) were treated following rupture. Procedure-related mortality and permanent neurologic deficits occurred in 2 (1.4%) and 5 patients (3.4%), respectively. In total, 7 patients (4.8%) died, including 2 with reruptures. Of the 140 surviving patients, 113 (80.7%) patients with 120 aneurysms were available for follow-up neurologic examination at a mean of 11.8 months. An increase in mRS score from admission to follow-up by 1, 2, or 3 points was seen in 7 (6.9%), 1 (1%), and 2 (2%) patients, respectively. Follow-up angiography was performed in 120 aneurysms at a mean of 11.9 months. Recanalization occurred in 12 aneurysms (10%), requiring retreatment in 7 (5.8%). Moderate in-stent stenosis was seen in 1 (0.8%), which remained asymptomatic. This series adds to the evidence demonstrating the safety and effectiveness of SACE in the treatment of intracranial aneurysms. However, SACE of ruptured aneurysms and premature termination of antiplatelet treatment are associated with increased morbidity and mortality.

  9. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.

    Science.gov (United States)

    Cannizzaro, Delia; Peschillo, Simone; Mancarella, Cristina; La Pira, Biagia; Rastelli, Emanuela; Passacantilli, Emiliano; Santoro, Antonio

    2017-06-01

    Intracranial carotid artery aneurysm can be treated via microsurgical or endovascular techniques. The optimal planning is the result of the careful patient selection through clinical, anatomic, and angiographic analysis. We present a case of ruptured internal carotid artery (ICA) aneurysm that became a complex aneurysm after failure of multi-endovascular and surgery treatment. We describe complete trapping in awake craniotomy after failure of coiling, stenting, and bypassing. ICA aneurysms could become complex aneurysms following multi-treatment failure. Endovascular approaches to treat ICA aneurysms include coiling, stenting, flow diverter stenting, and stenting-assisted coiling technique. The role of surgery remains relevant. To avoid severe neurologic deficits, recurrence, and the need of retreatment, a multidisciplinary discussion with experienced endovascular and vascular neurosurgeons is mandatory in such complex cases. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. Endovascular rescue method for undesirably stretched coil.

    Science.gov (United States)

    Cho, Jae Hoon

    2014-10-01

    Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter.

  11. Aneurysmal Subarachnoid Hemorrhage

    Science.gov (United States)

    2015-01-01

    Aneurysmal subarachnoid hemorrhage (SAH) is a worldwide health burden with high fatality and permanent disability rates. The overall prognosis depends on the volume of the initial bleed, rebleeding, and degree of delayed cerebral ischemia (DCI). Cardiac manifestations and neurogenic pulmonary edema indicate the severity of SAH. The International Subarachnoid Aneurysm Trial (ISAT) reported a favorable neurological outcome with the endovascular coiling procedure compared with surgical clipping at the end of 1 year. The ISAT trial recruits were primarily neurologically good grade patients with smaller anterior circulation aneurysms, and therefore the results cannot be reliably extrapolated to larger aneurysms, posterior circulation aneurysms, patients presenting with complex aneurysm morphology, and poor neurological grades. The role of hypothermia is not proven to be neuroprotective according to a large randomized controlled trial, Intraoperative Hypothermia for Aneurysms Surgery Trial (IHAST II), which recruited patients with good neurological grades. Patients in this trial were subjected to slow cooling and inadequate cooling time and were rewarmed rapidly. This methodology would have reduced the beneficial effects of hypothermia. Adenosine is found to be beneficial for transient induced hypotension in 2 retrospective analyses, without increasing the risk for cardiac and neurological morbidity. The neurological benefit of pharmacological neuroprotection and neuromonitoring is not proven in patients undergoing clipping of aneurysms. DCI is an important cause of morbidity and mortality following SAH, and the pathophysiology is likely multifactorial and not yet understood. At present, oral nimodipine has an established role in the management of DCI, along with maintenance of euvolemia and induced hypertension. Following SAH, hypernatremia, although less common than hyponatremia, is a predictor of poor neurological outcome. PMID:25272066

  12. Diffusion-Weighted Imaging-Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Bond, K M; Brinjikji, W; Murad, M H; Kallmes, D F; Cloft, H J; Lanzino, G

    2017-02-01

    Endovascular treatment of intracranial aneurysms is associated with the risk of thromboembolic ischemic complications. Many of these events are asymptomatic and identified only on diffusion-weighted imaging. We performed a systematic review and meta-analysis to study the incidence of DWI positive for thromboembolic events following endovascular treatment of intracranial aneurysms. A comprehensive literature search identified studies published between 2000 and April 2016 that reported postprocedural DWI findings in patients undergoing endovascular treatment of intracranial aneurysms. The primary outcome was the incidence of DWI positive for thromboembolic events. We examined outcomes by treatment type, sex, and aneurysm characteristics. Meta-analyses were performed by using a random-effects model. Twenty-two studies with 2148 patients and 2268 aneurysms were included. The overall incidence of DWI positive for thromboembolic events following endovascular treatment was 49% (95% CI, 42%-56%). Treatment with flow diversion trended toward a higher rate of DWI positive for lesions than coiling alone (67%; 95% CI, 46%-85%; versus 45%; 95% CI, 33%-56%; P = .07). There was no difference between patients treated with coiling alone and those treated with balloon-assisted (44%; 95% CI, 29%-60%; P = .99) or stent-assisted (43%; 95% CI, 24%-63%; P = .89) coiling. Sex, aneurysm rupture status, location, and size were not associated with the rate of DWI positive for lesions. One in 2 patients may have infarcts on DWI following endovascular treatment of intracranial aneurysms. There is a trend toward a higher incidence of DWI-positive lesions following treatment with flow diversion compared with coiling. Patient demographics and aneurysm characteristics were not associated with DWI-positive thromboembolic events. © 2017 by American Journal of Neuroradiology.

  13. Impact of anatomical variations of the circle of Willis on the incidence of aneurysms and their recurrence rate following endovascular treatment

    International Nuclear Information System (INIS)

    Songsaeng, D.; Geibprasert, S.; Willinsky, R.; Tymianski, M.; TerBrugge, K.G.; Krings, T.

    2010-01-01

    Aim: To analyse the impact of anatomical variations of the parent arteries on the incidence and recurrence rate following coil embolization of aneurysms of the anterior (AcoA), posterior communicating artery (PcoA) and basilar artery (BA) tip. Methods: Two hundred and two (96 AcoA, 67 PcoA, and 29 BA) aneurysms in 200 patients were treated with coil embolization between January 2000 and April 2008. Parent artery variations at each location were classified as: AcoA: A1 aplasia versus hypoplasia versus symmetrical size; PcoA: foetal origin versus medium versus small size, BA: cranial versus caudal versus asymmetrical fusion. The incidence of aneurysms and difference between recurrence rates for each group were recorded on follow-up. Results: AcoA, PcoA, and BA aneurysms were more often associated with embryonically earlier vessel wall dispositions (A1 aplasia, foetal PcoA, asymmetrical fusion). Two of these variations were also associated with aneurysm recurrence following coil embolization: asymmetrical A1 segment (p = 0.01), and asymmetrical BA tip (p = 0.02). Conclusions: AcoA, PcoA, and BA tip aneurysms tend to occur more often in anatomically variant parent artery dispositions, some of which are related to aneurysm recurrence following coil embolization. This may relate to a more fragile vessel disposition as it is not fully matured or to altered haemodynamics secondary to the anatomical variations.

  14. Impact of anatomical variations of the circle of Willis on the incidence of aneurysms and their recurrence rate following endovascular treatment

    Energy Technology Data Exchange (ETDEWEB)

    Songsaeng, D. [Division of Neuroradiology, Department of Medical Imaging, University of Toronto, Toronto (Canada); Department of Radiology, Siriraj Hospital, Faculty of Medicine, Mahidol University, Bangkok (Thailand); Geibprasert, S.; Willinsky, R. [Division of Neuroradiology, Department of Medical Imaging, University of Toronto, Toronto (Canada); Tymianski, M. [Department of Neurosurgery, Toronto Western Hospital, University of Toronto, Toronto (Canada); TerBrugge, K.G. [Division of Neuroradiology, Department of Medical Imaging, University of Toronto, Toronto (Canada); Krings, T., E-mail: timo.krings@uhn.on.c [Division of Neuroradiology, Department of Medical Imaging, University of Toronto, Toronto (Canada)

    2010-11-15

    Aim: To analyse the impact of anatomical variations of the parent arteries on the incidence and recurrence rate following coil embolization of aneurysms of the anterior (AcoA), posterior communicating artery (PcoA) and basilar artery (BA) tip. Methods: Two hundred and two (96 AcoA, 67 PcoA, and 29 BA) aneurysms in 200 patients were treated with coil embolization between January 2000 and April 2008. Parent artery variations at each location were classified as: AcoA: A1 aplasia versus hypoplasia versus symmetrical size; PcoA: foetal origin versus medium versus small size, BA: cranial versus caudal versus asymmetrical fusion. The incidence of aneurysms and difference between recurrence rates for each group were recorded on follow-up. Results: AcoA, PcoA, and BA aneurysms were more often associated with embryonically earlier vessel wall dispositions (A1 aplasia, foetal PcoA, asymmetrical fusion). Two of these variations were also associated with aneurysm recurrence following coil embolization: asymmetrical A1 segment (p = 0.01), and asymmetrical BA tip (p = 0.02). Conclusions: AcoA, PcoA, and BA tip aneurysms tend to occur more often in anatomically variant parent artery dispositions, some of which are related to aneurysm recurrence following coil embolization. This may relate to a more fragile vessel disposition as it is not fully matured or to altered haemodynamics secondary to the anatomical variations.

  15. Mycotic pulmonary artery aneurysm as an unusual complication of thoracic actinomycosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung-Soo; Lee, Sang-Yeub [Wonkwang University College, Iksan (Korea, Republic of); Oh, Yu-Whan; Noh, Hyung-Jun; Lee, Ki-Yeol; Kang, Eun-Young [Korea University Hospital and Korea University College, Seoul (Korea, Republic of)

    2004-03-15

    Although pulmonary artery aneurysms are a rare vascular anomaly, they are seen in a wide variety of conditions, such as congenital heart disease, infection, trauma, pulmonary hypertension, cystic medial necrosis and generalized vasculitis. To our knowledge, mycotic aneurysms caused by pulmonary actinomycosis have not been reported in the radiologic literature. Herein, a case of pulmonary actinomycosis complicated by mycotic aneurysm is presented. On CT scans, this case showed focal aneurysmal dilatation of a peripheral pulmonary artery within necrotizing pneumonia of the right lower lobe, which was successfully treated with transcatheter embolization using wire coils.

  16. Mycotic pulmonary artery aneurysm as an unusual complication of thoracic actinomycosis

    International Nuclear Information System (INIS)

    Kim, Hyung-Soo; Lee, Sang-Yeub; Oh, Yu-Whan; Noh, Hyung-Jun; Lee, Ki-Yeol; Kang, Eun-Young

    2004-01-01

    Although pulmonary artery aneurysms are a rare vascular anomaly, they are seen in a wide variety of conditions, such as congenital heart disease, infection, trauma, pulmonary hypertension, cystic medial necrosis and generalized vasculitis. To our knowledge, mycotic aneurysms caused by pulmonary actinomycosis have not been reported in the radiologic literature. Herein, a case of pulmonary actinomycosis complicated by mycotic aneurysm is presented. On CT scans, this case showed focal aneurysmal dilatation of a peripheral pulmonary artery within necrotizing pneumonia of the right lower lobe, which was successfully treated with transcatheter embolization using wire coils

  17. Flow-Diverting Devices versus Coil Embolization for Intracranial Aneurysms: A Systematic Literature Review and Meta-analysis.

    Science.gov (United States)

    Zhou, Geng; Zhu, Yue-Qi; Su, Ming; Gao, Kai-Di; Li, Ming-Hua

    2016-04-01

    To review the literature on flow-diverting device (FDD) treatments for intracranial aneurysms (IAs) and to compare the safety and efficacy of FDDs with coil embolization treatment (CET) for IAs using a meta-analysis of published studies. A systematic electronic search was conducted of PubMed, Springer Link, EBSCO, and the Cochrane Database on all accessible published articles through September 2015. Abstracts, full-text manuscripts, and the reference lists of retrieved articles were analyzed. Studies that explicitly compared FDD and CET approaches to the treatment of IAs were included. Odds ratios (ORs) and 95% CIs were calculated for the complete occlusion rate and the morbidity rate using a random-effects model. Nine studies were included in the analysis, containing retrospectively collected data for 863 patients. FDD treatment showed a significantly higher complete occlusion rate than CET (OR = 3.13; 95% confidence interval [CI], 2.11-4.65) and the subgroup of stent-assisted coiling did (OR = 2.08; 95% CI, 1.34-3.24). FDDs did not achieve a significantly lower overall morbidity rate compared with CET (OR = 0.87; 95% CI, 0.45-1.69) or the SAC (stent-assisted coiling) subgroup (OR = 0.86; 95% CI, 0.33-2.26), and our results did not show a significant difference in mortality between the two techniques. FDD treatment of IAs yielded satisfactory results in complete occlusion rate compared with CET. The FDD procedure is feasible and has no significant difference in morbidity risk. Despite the findings reported herein, further validation with well-designed, multicenter randomized controlled trials is needed. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Endovascular treatment of intracranial aneurysms using liquid polymer injection

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo

    2004-01-01

    Objective: To report our preliminary clinical experience in embolization of intracranial aneurysms with liquid polymer (Onyx). Methods: One case of posterior communicating artery aneurysm was treated with Onyx and microcoils, while the other one with multiple basilar aneurysms was treated by Onyx combined with stent-coiling technique. Results: All the aneurysms were totally occluded with patency of parent arteries. There was no procedure-related complication. The patients recovered well during clinical follow-up for 3 months. The angiographic follow-up in one patient showed the result was stable and Onyx was totally apart from the flow in parent artery. Conclusions: Short-term result suggests that endovascular treatment of intracranial aneurysms with liquid polymer is safe and effective, however more experience is needed. (authors)

  19. Tuberothalamic artery infarction following coil embolization of a ruptured posterior communicating artery aneurysm belonging to a transitional type posterior cerebral artery. A case report.

    Science.gov (United States)

    Lee, Kyeong Duk; Kwon, Soon Chan; Muniandy, Sarawana; Park, Eun Suk; Sim, Hong Bo; Lyo, In Uk

    2013-09-01

    There are many potential anatomical variations in the connection between the internal carotid artery and the posterior circulation through the posterior communicating artery (PCoA). We describe the endovascular treatment of an aneurysm arising near the origin of the PCoA belonging to a transitional type posterior cerebral artery. Coil embolization subsequently resulted in thrombo-occlusion of the adjacent PCoA causing thalamic infarction even though sufficient retrograde flow had been confirmed pre-operatively by Allcock's test.

  20. Giant aneurysm in 6 years old child - case report

    International Nuclear Information System (INIS)

    Sirakov, S.; Penkov, M.; Todorov, Y; Minkin, K.

    2014-01-01

    Intracranial saccular aneurysms rare in childhood is. Even among the reported series of childhood aneurysms, it is unusual to find their occurrence in children less than 7 years old. The pathogenesis of these lesions is also a matter of debate and speculations. The peak age of incidence of juvenile cerebral aneurysms appear to be 12 years, occurrence below the age of 7 being rarity. We show a case of 6 years old boy with giant aneurysm. found because of episodes of headache and vomiting. Discussion of pathogenesis for the rare pathology. After discussion of multidisciplinary team, of neuroradiologist and neurosurgeons was decided to be perform endovascular embolization, because of the better outcome for the patient. We performed endovascular treatment of the aneurysm with achieving total embolization. The patient recovery completely, and after 4 days went home. (authors) Key words: GIANT ANEURYSM. SACCULAR ANEURYSM. EMBOLIZATION. STENT ASSISTED COILING

  1. Management of aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Etminan, N; Macdonald, R L

    2017-01-01

    Spontaneous subarachnoid hemorrhage (SAH) affects people with a mean age of 55 years. Although there are about 9/100 000 cases per year worldwide, the young age and high morbidity and mortality lead to loss of many years of productive life. Intracranial aneurysms account for 85% of cases. Despite this, the majority of survivors of aneurysmal SAH have cognitive deficits, mood disorders, fatigue, inability to return to work, and executive dysfunction and are often unable to return to their premorbid level of functioning. The main proven interventions to improve outcome are aneurysm repair in a timely fashion by endovascular coiling rather than neurosurgical clipping when feasible and administration of nimodipine. Management also probably is optimized by neurologic intensive care units and multidisciplinary teams. Improved diagnosis, early aneurysm repair, administration of nimodipine, and advanced neurointensive care support may be responsible for improvement in survival from SAH in the last few decades. © 2017 Elsevier B.V. All rights reserved.

  2. Persistent neurological deficit from iodinated contrast encephalopathy following intracranial aneurysm coiling. A case report and review of the literature.

    LENUS (Irish Health Repository)

    Leong, S

    2012-03-01

    Neurotoxicity from iodinated contrast agents is a known but rare complication of angiography and neurovascular intervention. Neurotoxicity results from contrast penetrating the blood-brain barrier with resultant cerebral oedema and altered neuronal excitability. Clinical effects include encephalopathy, seizures, cortical blindness and focal neurological deficits. Contrast induced encephalopathy is extensively reported as a transient and reversible phenomenon. We describe a patient with a persistent motor deficit due to an encephalopathy from iodinated contrast media administered during cerebral aneurysm coiling. This observation and a review of the literature highlights that contrast-induced encephalopathy may not always have a benign outcome and can cause permanent deficits. This potential harmful effect should be recognised by the angiographer and the interventionalist.

  3. Impact of anatomical variations of the circle of Willis on the incidence of aneurysms and their recurrence rate following endovascular treatment.

    Science.gov (United States)

    Songsaeng, D; Geibprasert, S; Willinsky, R; Tymianski, M; TerBrugge, K G; Krings, T

    2010-11-01

    To analyse the impact of anatomical variations of the parent arteries on the incidence and recurrence rate following coil embolization of aneurysms of the anterior (AcoA), posterior communicating artery (PcoA) and basilar artery (BA) tip. Two hundred and two (96 AcoA, 67 PcoA, and 29 BA) aneurysms in 200 patients were treated with coil embolization between January 2000 and April 2008. Parent artery variations at each location were classified as: AcoA: A1 aplasia versus hypoplasia versus symmetrical size; PcoA: foetal origin versus medium versus small size, BA: cranial versus caudal versus asymmetrical fusion. The incidence of aneurysms and difference between recurrence rates for each group were recorded on follow-up. AcoA, PcoA, and BA aneurysms were more often associated with embryonically earlier vessel wall dispositions (A1 aplasia, foetal PcoA, asymmetrical fusion). Two of these variations were also associated with aneurysm recurrence following coil embolization: asymmetrical A1 segment (p=0.01), and asymmetrical BA tip (p=0.02). AcoA, PcoA, and BA tip aneurysms tend to occur more often in anatomically variant parent artery dispositions, some of which are related to aneurysm recurrence following coil embolization. This may relate to a more fragile vessel disposition as it is not fully matured or to altered haemodynamics secondary to the anatomical variations. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Total therapeutic embolization of the kidney for hypertension in a child with a mycotic aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, A.M.; Fisher, M.F.; Yoon, Y.S.

    1983-08-01

    A 7-year-old boy with bacterial endocarditis developed renal artery mycotic aneurysm and diffuse distal occlusions of the renal branches. Blood pressure in the patient returned to normal after obliteration of flow to the left kidney with Gelfoam, Ivalon, and a Gianturco coil. An end loop of the coil used for embolization remained in the lumen of the aorta against its lateral side. Improper coil placement did not result in complications; the boy later died due to neurologic and pulmonary complications. We discuss the therapeutic potential of renal embolization, as well as the risks of particulate and ethanol embolization, in the treatment of renal vascular hypertension from mycotic aneurysms.

  5. Total therapeutic embolization of the kidney for hypertension in a child with a mycotic aneurysm

    International Nuclear Information System (INIS)

    Cohen, A.M.; Fisher, M.F.; Yoon, Y.S.; University Hospitals of Cleveland, OH

    1983-01-01

    A 7-year-old boy with bacterial endocarditis developed renal artery mycotic aneurysm and diffuse distal occlusions of the renal branches. Blood pressure in the patient returned to normal after obliteration of flow to the left kidney with Gelfoam, Ivalon, and a Gianturco coil. An end loop of the coil used for embolization remained in the lumen of the aorta against its lateral side. Improper coil placement did not result in complications; the boy later died due to neurologic and pulmonary complications. We discuss the therapeutic potential of renal embolization, as well as the risks of particulate and ethanol embolization, in the treatment of renal vascular hypertension from mycotic aneurysms. (orig.)

  6. Total therapeutic embolization of the kidney for hypertension in a child with a mycotic aneurysm

    International Nuclear Information System (INIS)

    Cohen, A.M.; Fisher, M.F.; Yoon, Y.S.

    1983-01-01

    A 7-year-old boy with bacterial endocarditis developed renal artery mycotic aneurysm and diffuse distal occlusions of the renal branches. Blood pressure in the patient returned to normal after obliteration of flow to the left kidney with Gelfoam, Ivalon, and a Gianturco coil. An end loop of the coil used for embolization remained in the lumen of the aorta against its lateral side. Improper coil placement did not result in complications; the boy later died due to neurologic and pulmonary complications. We discuss the therapeutic potential of renal embolization, as well as the risks of particulate and ethanol embolization, in the treatment of renal vascular hypertension from mycotic aneurysms

  7. Advanced technical skills are required for microsurgical clipping of posterior communicating artery aneurysms in the endovascular era.

    Science.gov (United States)

    Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T

    2012-08-01

    Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.

  8. Late-Onset Massive Epistaxis due to a Ruptured Traumatic Internal Carotid Artery Aneurysm: A Case Report

    OpenAIRE

    Arai, Nobuhiko; Nakamura, Akiyoshi; Tabuse, Masanao; Miyazaki, Hiromichi

    2016-01-01

    A traumatic internal carotid artery (ICA) aneurysm is rare and difficult to treat. Trapping of ICA is commonly performed owing to the difficulty of directly approaching ICA aneurysms. Recently, coiling the aneurysm itself was recommended if possible. However, it is controversial which of methods are best to completely treat aneurysm. We present the case of a 74-year-old man, who had experienced a head injury 8 years previously, with recurrent severe epistaxis. An ICA aneurysm was detected on ...

  9. Endovascular treatment of the posterior inferior cerebellar artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Bradac, G.B.; Bergui, M. [Neuroradiology, Univ. di Torino, Turin (Italy)

    2004-12-01

    Aneurysms may arise at various locations along the course of the posterior inferior cerebellar artery. Brainstem and cranial nerves manipulation make the surgical approach to proximal aneurysms difficult, while the occlusion of the parent vessel is sometimes unavoidable in peripheral aneurysms. Endovascular treatment can be a good alternative, but also with this approach the location of the aneurysm is critical. If occlusion of the parent vessel is planned, anatomical variations and vascular territories of the brainstem should be considered. We report our experience with 18 consecutive aneurysms (12 proximal, 6 peripheral) treated by coils. Complete occlusion was achieved in 14 patients and subtotal in 4. In three patients the parent vessel had to be sacrificed. During treatment two perforations occurred; aneurysms were completely occluded without clinical consequences. Two small asymptomatic cerebellar infarctions were seen on postoperative computed tomography. Clinical outcome was good in 16 patients. (orig.)

  10. Parent artery occlusion for ruptured “true” posterior communicating artery aneurysm

    OpenAIRE

    Mitsuhashi, Takashi; Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-01-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgi...

  11. Predictors of residual flow in embolized intracranial ruptured aneurysms at early follow-up.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Beuth, Wojciech

    2014-01-01

    The possibility of recanalization and the need for retreatment are the most important drawbacks of intracranial aneurysm embolization. The purpose of the study was to prospectively analyze the results of early follow-up angiography of embolized ruptured aneurysms in an attempt to determine factors predicting the presence of residual flow. Evaluation included 72 patients with 72 aneurysms, which were followed-up 3 months after the treatment. Analysis of residual flow predictors included: age and gender, clinical state in Hunt-Hess scale, aneurysm localization, aneurysm three dimensions and volume, neck width, sac-to-neck ratio, initial result of embolization, number of coils used and the use of hydrogel coils and stents. Mean sac diameter was 6.5±3.9 mm, and mean neck width was 2.9±1.4 mm. Follow-up angiography presented residual flow in 26 aneurysms (36.1%): class 2 in 8 aneurysms (11.1%), and class 3 in 18 cases (25.0%). Stable aneurysm filling was observed in 45 cases (62.5%), progression of residual flow in 25 cases (34.7%), and regression in 2 cases (2.8%). According to ROC analysis independent predictors of residual flow were aneurysm neck diameter (AUC 0.857, 95% CI: 0.755-0.928, p<0.0001) and sac-to-neck ratio (AUC 0.817, 95% CI: 0.708-0.898, p<0.0001). Cut-off point of the ROC curve was established at 2.8 mm for neck diameter, and 1.73 for sac-to-neck ratio. Aneurysm neck diameter and sac-to-neck ratio are independently related to the residual flow in embolized ruptured aneurysms at early follow-up.

  12. Endovascular treatment of a true posterior communicating artery aneurysm.

    Science.gov (United States)

    Munarriz, Pablo M; Castaño-Leon, Ana M; Cepeda, Santiago; Campollo, Jorge; Alén, Jose F; Lagares, Alfonso

    2014-01-01

    Posterior communicating artery (PCoA) aneurysms are most commonly located at the junction of the internal carotid artery and the PCoA. "True" PCoA aneurysms, which originate from the PCoA itself, are rarely encountered. Most previously reported cases were treated surgically mainly before the endovascular option became available. A 53-year-old male presented with sudden onset of right hemiparesis and aphasia. Left middle cerebral artery stroke was diagnosed. Further studies revealed a 3 mm left PCoA aneurysm arising from the PCoA itself, attached to neither the internal carotid artery nor the posterior cerebral artery. Endovascular treatment was performed and the aneurysm was coiled completely. Technical advances in endovascular interventional technology have permitted an additional approach to these lesions. The possible endovascular significance of the treatment of true PCoA aneurysms is discussed.

  13. Selective embolization of unruptured intracranial aneurysms is associated with low retreatment rate

    Energy Technology Data Exchange (ETDEWEB)

    Bandeira, Alexandra; Raphaeli, Guy [Erasme University Hospital, Department of Radiology, Neuroradiology Section, Brussels (Belgium); Erasme University Hospital, Interventional Neuroradiology Fellows, Brussels (Belgium); Baleriaux, Danielle [Erasme University Hospital, Department of Radiology, Neuroradiology Section, Brussels (Belgium); Bruneau, Michael; Witte, Olivier De [Erasme University Hospital, Neurosurgery, Brussels (Belgium); Lubicz, Boris [Erasme University Hospital, Department of Radiology, Neuroradiology Section, Brussels (Belgium); Hopital Erasme, Service de Radiologie, Brussels (Belgium)

    2010-02-15

    To report long-term imaging findings of 101 patients with 129 unruptured intracranial aneurysms (UIA) treated by embolization. A retrospective review of our prospectively maintained database identified all patients with an UIA treated by embolization with coils only and with a minimal 12-month imaging follow-up. The clinical charts, procedural data, and angiographic results were reviewed. Between March 2004 and June 2009, 101 patients with 129 UIA were identified (71 women/30 men, mean age = 51.4 years). Ninety-four aneurysms (73%) were large (10-25 mm), and 35 (27%) were small (<10 mm). Aneurysms mean size was 10.7 mm (median, 9 mm; range 3-22 mm); 87 UIA (67.5%) had a small neck (<4 mm or neck/sac ratio < 0.7), and 42 (32.5%) had a wide neck ({>=}4 mm or neck/sac ratio {>=} 0.7). Selective coiling with bare/coated coils was performed in 125 cases and four cases, respectively. The balloon-assisted technique was used in 47 cases (36.4%). Only one patient experienced a symptomatic complication (thromboembolism) and kept a slight hemiparesis. Immediate results included 77 complete occlusions (59.7%), 45 neck remnants (34.9%), and 7 incomplete occlusions (5.4%). Mean imaging follow-up of 32 months showed 104 stable occlusions (80.6%), 12 further thrombosis (9.3%), 7 major recanalizations (5.4%), and 6 minor recanalizations (4.7%). Retreatment was required in seven wide-necked and/or large aneurysms including four treated with coated coils. No bleeding occurred during follow-up. Selective embolization of UIA is associated with stable long-term anatomical results and low retreatment rate. (orig.)

  14. Delayed thrombosis or stenosis following enterprise-assisted stent-coiling: is it safe? Midterm results of the interstate collaboration of enterprise stent coiling.

    Science.gov (United States)

    Mocco, J; Fargen, Kyle M; Albuquerque, Felipe C; Bendok, Bernard R; Boulos, Alan S; Carpenter, Jeffrey S; Fiorella, David J; Hoh, Brian L; Howington, Jay U; Liebman, Kenneth M; Natarajan, Sabareesh K; Rai, Ansaar T; Rodriguez-Mercado, Rafael; Siddiqui, Adnan H; Snyder, Kenneth V; Veznedaroglu, Erol; Hopkins, L Nelson; Levy, Elad I

    2011-10-01

    Stent-assisted coiling of intracranial aneurysms with self-expanding stents has widened the applicability of neuroendovascular therapies to those aneurysms previously considered "uncoilable" because of poor morphology. The Enterprise Vascular Reconstruction Device and Delivery System (Cordis) has demonstrated promising initial short-term results. However, the rates of delayed in-stent stenosis or thrombosis are not known. To report midterm results of the Enterprise stent system. A 10-center registry was created to provide a large volume of data on the safety and efficacy of the Enterprise stent system. Pooled data were compiled for consecutive patients undergoing Enterprise stent-assisted coiling at each institution. Available follow-up data were evaluated for the incidence of in-stent stenosis, thrombosis, and aneurysm occlusion. In total, 213 patients (176 females) with 219 aneurysms were treated with the Enterprise stent. One hundred ten patients had undergone delayed angiography (≥ 30 days from stent placement, mean follow-up 174.6 days). Forty percent of patients demonstrated total occlusion with 88% having ≥ 90% aneurysm occlusion. Six percent of patients had delayed (>30 days) angiographic findings, of which 3% demonstrated significant (≥ 50%) in-stent stenosis or occlusion. Seven delayed thrombotic events occurred (3%), along with 2 additional immediate periprocedural events. All 7 delayed events were concomitant to cessation of double-antiplatelet therapy. Midterm occlusion rates are excellent, and stenosis and thrombosis rates are comparable to other available neurovascular stents. Interruption of antiplatelet therapy appears to be a factor in those developing delayed stenosis or thrombosis.

  15. Endovascular treatment of renal aneurysms: A series of 18 cases

    International Nuclear Information System (INIS)

    Sédat, J.; Chau, Y.; Baque, J.

    2012-01-01

    Purpose: To retrospectively analyze the results and complications of the endovascular treatment of 18 renal aneurysms. Methods: From 2002 to 2011, 15 patients (aged 31–76), with 18 renal aneurysms, were admitted in our institution for treatment by embolization. Except one, all were wide-necked aneurysms. One aneurysm was treated by occluding the parent artery considering its distal location; a small-necked aneurysm was treated by simple coiling, and the remaining 16 were embolized utilizing adjunctive techniques to protect the parent artery. We analyzed the rates of technical success, complication and clinical consequence, post-operative occlusion and recurrence. Results: There was a 100% technical success rate. 15 aneurysms showed a total occlusion on the post-treatment angiogram. 2 aneurysms demonstrated neck remnants, and one had an intrasaccular residual in-flow. Two minor post-operative complications were encountered but resolved over time. No delayed clinical complications were observed and the long-term angiographic follow-up demonstrated stability of the occlusion of the target renal aneurysm with no major recurrence. Conclusion: Complications of the embolization of renal aneurysms are rare. Endovascular treatment should therefore be considered at first for the treatment of renal aneurysms.

  16. [An implantable micro-device using wireless power transmission for measuring aortic aneurysm sac pressure].

    Science.gov (United States)

    Guo, Xudong; Ge, Bin; Wang, Wenxing

    2013-08-01

    In order to detect endoleaks after endovascular aneurysm repair (EVAR), we developed an implantable micro-device based on wireless power transmission to measure aortic aneurysm sac pressure. The implantable micro-device is composed of a miniature wireless pressure sensor, an energy transmitting coil, a data recorder and a data processing platform. Power transmission without interconnecting wires is performed by a transmitting coil and a receiving coil. The coupling efficiency of wireless power transmission depends on the coupling coefficient between the transmitting coil and the receiving coil. With theoretical analysis and experimental study, we optimized the geometry of the receiving coil to increase the coupling coefficient. In order to keep efficiency balance and satisfy the maximizing conditions, we designed a closed loop power transmission circuit, including a receiving voltage feedback module based on wireless communication. The closed loop improved the stability and reliability of transmission energy. The prototype of the micro-device has been developed and the experiment has been performed. The experiments showed that the micro-device was feasible and valid. For normal operation, the distance between the transmitting coil and the receiving coil is smaller than 8cm. Besides, the distance between the micro-device and the data recorder is within 50cm.

  17. Experimental Study of Flow Through Carotid Aneurysms

    Science.gov (United States)

    Masoomi, Faezeh; Mejia-Alvarez, Ricardo

    2017-11-01

    There is evidence that traditional endovascular techniques like coiling are not effective for treatment of wide-neck cerebral aneurysms. Flow Diverter Stents (FDS) have emerged as promising devices for treating complex aneurysms since they enable treatment of aneurysms that were considered untreatable before. Recent studies suggest a number of associated risks with FDS, including in-stent thrombosis, perianeurysmal edema, delayed hemorrhage, and perforator occlusions. Chong et al. simulated hemodynamic behavior using patient-specific data. From their study, it is possible to infer that the standard deviation of energy loss could be a good predictor for intervention success. The aim of this study is to investigate the flow in models of cerebral aneurysms before and after FDS insertion using PIV. These models will be based on actual clinical studies and will be fabricated with advanced additive manufacturing techniques. These data will then be used to explore flow parameters that could inform the likelihood of post-intervention aneurysm rupture, and help determine FDS designs that better suit any particular patient before its procedure.

  18. Anaesthetic and ICU management of aneurysmal subarachnoid haemorrhage: a survey of European practice.

    Science.gov (United States)

    Velly, Lionel J; Bilotta, Federico; Fàbregas, Neus; Soehle, Martin; Bruder, Nicolas J; Nathanson, Michael H

    2015-03-01

    Many aspects of the perioperative management of aneurysmal subarachnoid haemorrhage (SAH) remain controversial. It would be useful to assess differences in the treatment of SAH in Europe to identify areas for improvement. To determine the clinical practice of physicians treating SAH and to evaluate any discrepancy between practice and published evidence. An electronic survey. Physicians identified through each national society of neuroanaesthesiology and neurocritical care. A 31-item online questionnaire was distributed by the ENIG group. Questions were designed to investigate anaesthetic management of SAH and diagnostic and treatment approaches to cerebral vasospasm. The survey was available from early October to the end of November 2012. Completed surveys were received from 268 respondents, of whom 81% replied that aneurysm treatment was conducted early (within 24 h). Sixty-five percent of centres treated more than 60% of SAH by coiling, 19% had high-volume clipping (>60% of aneurysms clipped) and 16% used both methods equally. No clear threshold for arterial blood pressure target was identified during coiling, temporary clipping or in patients without vasospasm after the aneurysm had been secured. Almost all respondents used nimodipine (97%); 21% also used statins and 20% used magnesium for prevention of vasospasm. A quarter of respondents used intra-arterial vasodilators alone, 5% used cerebral angioplasty alone and 48% used both endovascular methods to treat symptomatic vasospasm. In high-volume clipping treatment centres, 58% of respondents used endovascular methods to manage vasospasm compared with 86% at high-volume coiling treatment centres (P practice patterns of European physicians involved in early treatment of SAH. Significant differences were noted among countries and between high and low-volume coiling centres.

  19. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Bongers, Malte Niklas [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-07-15

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  20. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    International Nuclear Information System (INIS)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian; Bongers, Malte Niklas

    2017-01-01

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  1. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  2. Functional outcome of microsurgical clipping compared to endovascular coiling.

    Science.gov (United States)

    Premananda, R M; Ramesh, N; Hillol, K P

    2012-12-01

    Endovascular coiling has been used increasingly as an alternative to neurosurgical clipping for treating subarachnoid hemorrhage secondary to aneurysm rupture. In a retrospective cohort review on the treatment methods of aneurysm rupture in Hospital Kuala Lumpur over the period of five years (2005-2009) a total of 268 patients were treated. These patients were broadly categorized into two groups based on their treatment mode for ruptured aneurysms. Statistical analysis was determined using Chi- Square tests to study these associations. In our study, 67.5% of patients presented with Good World Federation of Neurosurgical Societies (WFNS) grade (WFNS1-2) while 32.5% patients presented with Poor WFNS prior to intervention. In our outcome, it was noted that 60.4% had good functional outcome (mRS grade 0-2) as compared to 39.6% patients who had poor mRS(modified rankin scale) outcome (mRS 3-6). In the good WFNS group, 76% of patients in clipping group had a good mRS outcome while, 86.5% patients in coiling group had good mRS outcome (p=0.114). In poor WFNS presentation, it was noted that in 77.3% patients in clipping group, had poor mRS outcome. Similarly with poor WFNS presentation, 83.3% of patient in coiling group had poor outcome. (p=1.00). Hence when we control the WFNS group, there was no significant association between treatment group (clipping and coiling) and mRS outcome at 6 months. The outcome of patient is determined by initial clinical presentation (WFNS grade) and influenced by requirement of Extraventricular drain (EVD) in presence of hydrocephalus, CSF infection and pneumonia. Therefore the decision regarding treatment option needs to be individualized based on the presentation of the patient.

  3. Surgical management of recurrent intracranial aneurysms after embolization

    Directory of Open Access Journals (Sweden)

    Hua-wei WANG

    2015-03-01

    Full Text Available Background Endovascular therapy is the first treatment choice for intracranial aneurysms currently, but it has a high recurrence rate. Some patients require surgical clipping because of the difficulty of re-embolization. This study retrospectively analyzed the clinical data of 11 cases who underwent clipping operation because of the recurrence after endovascular therapy. Combining with domestic and foreign related literatures, this paper discusses the principles and techniques of surgical treatment for recurrent aneurysms.  Methods There were a total of 11 patients with 12 recurrent aneurysms after embolization, including 3 anterior communicating artery (ACoA aneurysms, 3 middle cerebral artery (MCA aneurysms, 2 posterior communicating artery (PCoA aneurysms, one anterior cerebral artery (ACA aneurysm, one vertebral artery (VA aneurysm, one basilar tip aneurysm and one superior cerebellar artery (SCA aneurysm. There were 7 small aneurysms and 4 large aneurysms. All patients underwent surgical clipping under microscope. After operation, 11 aneurysms were complete clipped, and one was proximally blocked. The coils were reserved in 7 aneurysms, and were removed or partially removed in 5 aneurysms.  Results All patients were followed up for an average of 22 months after surgery. There were 9 cases (9/11 with the Glasgow Outcome Scale (GOS score improved or remaining unchanged compared with preoperation. One of them presented left limb weakness after operation, with the muscle strength Grade 3, while recovered to Grade 4-5 on discharge. The other 2 patients died after surgery. One case had a critical condition before surgery, and the other was secondary to thrombosis and pneumonia. Both of them had a GOS score of 2 when discharged, and died after discharge.  Conclusions There is high surgical difficulty in recurrent aneurysms, however, with adequate preoperative evaluation and surgical design, it can still promise safe and effective results

  4. Endovascular Treatment of a Splenic Aneurysm Associated With Segmental Arterial Mediolysis

    Directory of Open Access Journals (Sweden)

    A. Khan

    Full Text Available : Introduction: Segmental arterial mediolysis is a rare disorder characterised by disintegration of the medial layer of an arterial wall usually affecting the intra-abdominal splanchnic vessels. Report: A case of 50 year old man who presented with sudden-onset left sided flank pain is reported. A computed tomography mesenteric angiogram showed haemorrhage and a stable left upper quadrant haematoma arising from 8 × 8 mm splenic artery aneurysm. Discussion: The patient underwent a successful endovascular coiling procedure to exclude the aneurysm and for complete resolution of his symptoms. Keywords: Segmental arterial mediolysis, Splanchnic vessels, Splenic artery aneurysm

  5. Glue embolization of the giant aneurysm by reducing thrombosis-induced volume expansion effect

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Yoo Kyung; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2015-04-15

    A giant aneurysm due to a large intra-aneurysmal volume can be complicated by a delayed massive volume expansion caused by thrombus formation. To prevent such a severe mass effect, we obliterated the aneurysmal lumen by gluing and prevented further development of thrombosis. A 52-year-old female with a giant aneurysm at the cavernous segment of the internal carotid artery presented with tinnitus and intermittent diplopia. After confirming with a negative occlusion test, the right internal carotid artery was trapped by coiling and with further obliteration of the aneurysmal lumen by gluing. She developed a mild diplopia after the procedure and recovered without any deficit. The magnetic resonance angiography showed a stable occlusion of the aneurysm and good collateral filling of the cerebral vessel 15 months later.

  6. Glue embolization of the giant aneurysm by reducing thrombosis-induced volume expansion effect

    International Nuclear Information System (INIS)

    Yeom, Yoo Kyung; Suh, Dae Chul

    2015-01-01

    A giant aneurysm due to a large intra-aneurysmal volume can be complicated by a delayed massive volume expansion caused by thrombus formation. To prevent such a severe mass effect, we obliterated the aneurysmal lumen by gluing and prevented further development of thrombosis. A 52-year-old female with a giant aneurysm at the cavernous segment of the internal carotid artery presented with tinnitus and intermittent diplopia. After confirming with a negative occlusion test, the right internal carotid artery was trapped by coiling and with further obliteration of the aneurysmal lumen by gluing. She developed a mild diplopia after the procedure and recovered without any deficit. The magnetic resonance angiography showed a stable occlusion of the aneurysm and good collateral filling of the cerebral vessel 15 months later.

  7. Cranio-orbital approach for complex aneurysmal surgery.

    LENUS (Irish Health Repository)

    Kelleher, M O

    2012-02-03

    Certain aneurysms of the anterior circulation continue to offer a technical challenge for safe exposure and clipping. The purpose of this paper was to describe the cranio-orbital approach for surgical clipping of complex aneurysms and to evaluate prospectively the associated complications of this approach. Prospective audit of all patients undergoing cranio-orbital approach for aneurysm surgery from 1997 to 2004 by the senior author. Twenty-five patients, eight male and 17 female, median age of 52 years, range 28-73. All patients had a standard pterional approach supplemented by an orbital osteotomy. In the 7-year period 367 patients underwent treatment for their aneurysms (169 clipped and 198 coiled). Of the 169 patients who were operated on, 29 had a skull base approach, of which 25 were cranio-orbital. The aneurysm location was as follows: 16 middle cerebral artery (MCA), three carotid bifurcation, four anterior communicating artery (ACOMM), one ophthalmic and one basilar. There were no approach-related complications. The cranio-orbital craniotomy can be a useful adjunct in the surgical treatment of giant or complex aneurysms. It offers the following advantages over a standard pterional approach: reduces operative distance; allows easy splitting of the sylvian fissure; and provides a wide arc of exposure with multiple working corridors.

  8. Immediate endovascular treatment of an aortoiliac aneurysm ruptured into the inferior vena cava.

    Science.gov (United States)

    Kopp, Reinhard; Weidenhagen, Rolf; Hoffmann, Ralf; Waggershauser, Tobias; Meimarakis, Georgios; Andrassy, Joachim; Clevert, Dirk; Czerner, Stephan; Jauch, Karl-Walter

    2006-07-01

    An aortocaval fistula is a severe complication of an aortoiliac aneurysm, usually associated with high perioperative morbidity and mortality during open operative repair. We describe the successful endovascular treatment of a symptomatic infrarenal aortic aneurysm ruptured into the inferior vena cava with secondary interventional coiling of a persistent type II endoleak because of retrograde perfusion of the inferior mesenteric artery. Endovascular exclusion of ruptured abdominal aneurysms seems to be a valuable treatment option for selected patients even with complicated vascular conditions like an aortocaval fistula.

  9. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    Science.gov (United States)

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  10. Return of visual function after bilateral visual loss following flow diversion embolization of a giant ophthalmic aneurysm due to both reduction in mass effect and reduction in aneurysm pulsation.

    Science.gov (United States)

    Patel, Saharsh; Fargen, Kyle M; Peters, Keith; Krall, Peter; Samy, Hazem; Hoh, Brian L

    2015-01-01

    Large and giant paraclinoid aneurysms are challenging to treat by either surgical or endovascular means. Visual dysfunction secondary to optic nerve compression and its relationship with aneurysm size, pulsation and thrombosis is poorly understood. We present a patient with a giant paraclinoid aneurysm resulting in bilateral visual loss that worsened following placement of a Pipeline Embolization Device and adjunctive coiling. Visual worsening occurred in conjunction with aneurysm thrombosis, increase in maximal aneurysm diameter and new adjacent edema. Her visual function spontaneously improved in a delayed fashion to better than pre-procedure, in conjunction with reduced aneurysmal mass effect, size and pulsation artifact on MRI. This report documents detailed ophthalmologic and MRI evidence for the role of thrombosis, aneurysm mass effect and aneurysm pulsation as causative etiologies for both cranial nerve dysfunction and delayed resolution following flow diversion treatment of large cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Transcatheter Embolization of Pulmonary Artery False Aneurysm Associated with Primary Pulmonary Hypertension

    International Nuclear Information System (INIS)

    Hiraki, T.; Kanazawa, S.; Mimura, H.; Yasui, K.; Okumura, Y.; Dendo, S.; Yoshimura, K.; Takahara, M.; Hiraki, Y.

    2004-01-01

    A 29-year-old woman with primary pulmonary hypertension presented with recurrent hemoptysis. Contrast-enhanced CT of the chest demonstrated the enhanced mass surrounded by consolidation related to parenchymal hemorrhage. Pulmonary angiography suggested that the mass was a pulmonary artery false aneurysm. After a microcatheter was superselectively inserted into the parent artery of the falseaneurysm, the false aneurysm was successfully treated by transcatheterembolization with coils. Her hemoptysis has never recurred

  12. Asymptomatic giant coronary aneurysm in an adolescent with Behcet's syndrome

    Directory of Open Access Journals (Sweden)

    Kahn Philip J

    2012-01-01

    Full Text Available Abstract Objective Behcet's is an idiopathic multi-organ syndrome, which may have onset during childhood. Vascular involvement is uncommon, with rarely reported coronary aneurysm formation. We present a case report of a teenager girl who developed recalcitrant life-threatening Behcet's vasculitis, involving both small and large venous and arterial systems including a giant coronary aneurysm. Case report De-identified data were collected retrospectively in case report format. Although our sixteen year old female with Behcet's vasculitis had resolution of many arterial aneurysms, she had persistent venous thrombosis of large vessels, as well as persistent, giant arterial aneurysms requiring intra-arterial coiling of a lumbar artery and coronary bypass grafting despite intensive immunosuppression including glucocorticoids, cyclophosphamide, infliximab, methotrexate, azathioprine and intravenous immunoglobulin. Conclusions Vascular manifestations may be seen in Behcet's syndrome, including asymptomatic coronary aneurysm, which may be refractory to immunosuppression and ultimately require surgical intervention. Increased awareness is essential for prompt diagnosis and management.

  13. Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome

    International Nuclear Information System (INIS)

    Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping

    2004-01-01

    Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)

  14. Treatment Modality and Quality Benchmarks of Aneurysmal Subarachnoid Hemorrhage at a Comprehensive Stroke Center

    Directory of Open Access Journals (Sweden)

    Wengui Yu

    2018-03-01

    Full Text Available BackgroundAneurysmal subarachnoid hemorrhage (aSAH is the most severe type of stroke. In 2012, the Joint Commission, in collaboration with the American Heart Association/American Stroke Association (AHA/ASA, launched the Advanced Certification for Comprehensive Stroke Centers (CSCs. This new level of certification was designed to promote higher standard of care for patients with complex stroke.ObjectiveThe goal of this study was to examine the treatment modality and quality benchmarks of aSAH at one of the first five certified CSCs in the United States.MethodsConsecutive patients with aSAH at Cedars-Sinai Medical Center between April 1, 2012 and May 30, 2014 were included for this retrospective study. The ruptured aneurysm was treated with coiling or clipping within 24 h. All patients were managed per AHA guidelines. Discharge outcomes were assessed using modified Rankin Scale (mRS. The rate of aneurysm treatment, door-to-treatment time, rate of posttreatment rebleed, hospital length of stay (LOS, discharge outcome, and mortality rates were evaluated as quality indicators.ResultsThe median age (interquartile range of the 118 patients with aSAH was 55 (19. Among them, 84 (71.2% were females, 94 (79.7% were transfers from outside hospitals, and 74 (62.7% had Hunt and Hess grades 1–3. Sixty patients (50.8% were treated with coiling, 52 (44.1% with clipping, and 6 (5.1% untreated due to ictal cardiac arrest or severe comorbidities. The rate of aneurysm treatment was 95% (112/118 with median door-to-treatment time at 12.5 (8.5 h and 0.9% (1/112 posttreatment rebleed. The median ICU and hospital LOS were 12.5 (7 and 17.0 (14.5 days, respectively. Coiling was associated with significantly shorter LOS than clipping. There were 59 patients (50% with favorable outcome and 19 deaths (16.1% at hospital discharge. There was no significant difference in discharge outcome between coiling and clipping.ConclusionCare of aSAH at one of the early CSCs in the

  15. Comparison of enterprise and neuroform stent-assisted coil embolization of distal internal carotid artery aneurysms: Midterm results from a single-center experience

    International Nuclear Information System (INIS)

    Choi, Won Jin; Baik, Seung Kug; Yeom, Jeong A; Kim, Young Soo; Lee, Sang Weon

    2014-01-01

    To compare the mid-term follow-up angiographic findings in distal internal carotid artery (ICA) aneurysms treated by stent-assisted coil embolization using the Enterprise or Neuroform stent. We included 68 patients with 70 aneurysms: 31 cases with Enterprise and 39 cases with Neuroform. Inclusion criteria were 1) location of the stent within the distal ICA, including the carotid siphon; 2) follow-up angiogram after > 6 months, and 3) single use of the stent for 1 parent artery. The patients' mean age was 54.9 years (16 male and 52 female). Mean follow-up duration was 9.1 months. At follow-up, there were intraluminal filling defects of the parent artery in 19.4% of the Enterprise group and no filling defect in the Neuroform group. There was no significant in-stent stenosis in either group. Straightening of the parent artery was seen in 35.5% of the Enterprise group and 20.5% of the Neuroform group. Two Enterprise cases showed delayed migration. The Enterprise showed statistically significant intraluminal filling defects of the parent artery compared with the Neuroform. The rates of significant in-stent stenosis and straightening of the parent artery were not significantly different between the Enterprise and the Neuroform groups.

  16. Progressive Occlusion of Enterprise Stent-Assisted Coiling of Ruptured Wide-Necked Intracranial Aneurysms and Related Factors on Angiographic Follow-Up: A Single-Center Experience with 468 Patients

    Science.gov (United States)

    Liu, Aihua; Li, Youxiang; Jiang, Chuhan; Wu, Zhongxue

    2014-01-01

    This study was designed to assess the effect of the Enterprise stent on progressive occlusion of wide-necked aneurysms and to evaluate the association between dubious factors and progressive occlusion, which is a consecutive, retrospective, single-center study. Data from 468 patients with 495 wide-necked aneurysms, who had undergone Enterprise stent-assisted coiling (SAC) were reviewed, and the clinical outcomes and the angiographic results were analyzed. A 14-month clinical follow-up was achieved in 421 of the 468 patients (90.0%), showing modified Rankin Scale (mRS) 0–1 in 364 (86.4%), mRS 2 in 17 (4.1%), mRS 3 in 17 (4.1%), mRS 4–5 in 9 (2.1%), and mRS 6 in 14 (3.3%) patients. Overall, the morbidity and mortality were 10.2% and 3.3%, respectively. Initial angiographic results showed Raymond scale (RS)1 in 273 (55.2%), RS2 in 194 (39.2%), and RS3 in 28 (5.6%) patients. Eight-month angiographic follow-up was available in 394 of 495 patients (79.6%), and RS1 was seen in 315 (79.9%), RS2 in 65 (16.5%) and RS3 in 14 (3.6%) cases. At the end of the follow-up, 115 of the 165 (69.7%) patients with initial RS2 and RS3 showed progressive occlusion. Statistical analysis showed no significant difference between progressive occlusion and age (p = 0.654), sex (p = 0.016), aneurysm diameter (p = 0.010), neck size (p = 0.124), dome-to neck ratio (DNR) (p = 0.018) and location (p = 0.001) at the time of follow-up. SAC using Enterprise stent is not only feasible for wide-necked aneurysms, but can achieve a high rate of progressive occlusion with good clinical outcomes at medium-term follow-up. Patient age and aneurysm neck size showed no associated with progressive occlusion at follow-up, while sex, aneurysm diameter, DNR and location were significantly associated with progressive occlusion. PMID:24658387

  17. Treatment of Endovascular Coil and Stent Migration Using the Merci Retriever: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    David K. Kung

    2012-01-01

    Full Text Available Background. Coil and stent migration is a potentially catastrophic complication in endovascular neurosurgery, which may lead to cerebral thromboembolism. Techniques for removing migrated coil and stent are not well established. Methods and Results. We present three cases in which coil or stent migration occurred during endovascular embolization of a cerebral aneurysm. The Merci Retrievers were used successfully in all cases to remove the displaced foreign bodies. Technical details are described. Conclusion. The Merci Retriever device can be utilized successfully for removal of migrated coils and stents in endovascular neurosurgery.

  18. Therapeutic effect of enterprise stent-assisted embolization for very small ruptured intracranial aneurysms.

    Science.gov (United States)

    Qin, Feiyun; Li, Zhenbao; Fang, Xinggen; Zhao, Xintong; Liu, Jiaqiang; Wu, Degang; Lai, Niansheng

    2017-08-01

    Enterprise stent has been widespread used in wide-necked intracranial aneurysms and good efficacy has been achieved, but there are few reports on its applications in very small ruptured intracranial aneurysms in literatures. This study aimed to evaluate the safety and efficacy of Enterprise stent-assisted coiling embolization of very small ruptured intracranial aneurysms.We retrospectively reviewed the clinical and imaging data from 37 patients with very small ruptured intracranial aneurysms who had SAC using Enterprise stents performed from February 2012 to July 2016 in our department. Data collected and analyzed included patient demographics, morphologic features of the aneurysm, treatment results, and follow-up results. Clinical outcomes were evaluated by the Glasgow Outcome Scale (GOS).Enterprise stents were successfully implanted in all 37 patients with very small ruptured intracranial aneurysms. Of the 37 individuals, 28 patients exhibited complete occlusion at Raymond grade I, 5 patients exhibited occlusion at Raymond grade II, and 4 patients at Raymond grade III. Procedure-related complications occurred in 3 of 37 patients (8.1%), including 1 case of intraprocedure aneurysm rupture who died from cerebral herniation caused by severe postoperative cerebral ischemia during the hospital stay, and the other 2 complications were acute in-stent thrombosis, and occlusion of parent artery caused by falling-off internal carotid artery plaque, respectively. A total of 36 patients underwent postoperative clinical follow-up visits for 6 to 24 months of which 31 patients recovered (GOS ≥ 4). One patient had hemiplegic paralysis, and no rehemorrhage was found. A total of 25 patients underwent follow-up digital subtraction angiography (DSA) at 3-21 months postintervention, in whom there were 22 cases with complete occlusion, 2 cases with recurrence of aneurysm neck, and 1 case with in-stent restenosis, but there was no patient with neurologic deficits.The Enterprise

  19. Systemic Multiple Aneurysms Caused by Vascular Ehlers-Danlos Syndrome.

    Science.gov (United States)

    Gui, Xinyu; Li, Fangda; Wu, Lingeer; Zheng, Yuehong

    2016-07-01

    Systemic multiple aneurysms are rare and usually associated with collagen tissue disease, such as Ehlers-Danlos syndrome (EDS) or Marfan syndrome. In the present case, we describe a 39-year-old male patient with systemic multiple aneurysms and acute intraperitoneal hemorrhage who was clinically diagnosed with vascular EDS. Coil embolization of the distal segment of the common hepatic artery was performed, which resolved the patient's symptoms. With this case presentation, we aim to increase the awareness of vascular EDS among clinicians and emphasize the extreme fragility of the arteries in patients with vascular EDS. © The Author(s) 2016.

  20. Nursing experience in clinical endovascular treatment for renal artery aneurysms

    International Nuclear Information System (INIS)

    Dong Yanfen; Pan Xiaoxia; Luan Shaoliang; Wei Ren

    2012-01-01

    Objective: To discuss the standardized clinical nursing measures for patients receiving endovascular treatment of renal artery aneurysms. Methods: The clinical data of 9 patients with renal artery aneurysm, who were admitted to authors' hospital during the period from Jan. 2010 to Aug. 2011 and received endovascular treatment, were retrospectively analyzed. The related nursing points as well as the received endovascular. Results: A total of 9 cases with renal artery aneurysm were treated nursing measures were summarized. Results: A total of 9 cases with renal artery aneurysm were with interventional management, including embolization (n = 6), stent implantation (n = 2) and stent implantation together with coil embolization (n = 1). The mean hospitalization time was (10±2) days. Postoperative retention of urine was observed in one patient and postoperative retroperitoneal hemorrhage occurred in another patient. Neither nursing-related nor operation-related complications occurred. Conclusion: Standardized perioperative nursing care for patients with renal artery aneurysm can surely help enhance the patient's tolerance to the surgery, and effectively prevent the complications. (authors)

  1. Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms.

    Science.gov (United States)

    Feng, Xin; Qian, Zenghui; Liu, Peng; Zhang, Baorui; Wang, Luyao; Guo, Erkang; Wen, Xiaolong; Xu, Wenjuan; Jiang, Chuhan; Wu, Zhongxue; Li, Youxiang; Liu, Aihua

    2018-01-01

    To compare the rates of recanalization and in-stent stenosis between the Enterprise (EP) and low-profile visualized intraluminal support (LVIS) stent deployments for intracranial aneurysms (IAs), and the factors associated therein. Between June 2014 and July 2016, 142 patients with a total of 161 IAs were treated by LVIS stent-assisted coiling and 111 patients with a total of 142 IAs were treated by EP stent-assisted coiling at our institution. Procedure-related complications, angiographic follow-up results, and clinical outcomes were analyzed statistically. The rates of initially complete and near-complete IA occlusion immediately after the procedure were similar in the LVIS and EP groups (94.3% vs. 89.9%; P = 0.275). On follow-up, complete and near-complete occlusion rates and recanalization rates were also similar in the 2 groups (96.6% vs. 92.1%; P =0.330 and 8.0% vs. 13.5%; P = 0.245, respectively). On logistic regression analysis, a higher size ratio (SR) was significantly associated with the recanalization of aneurysms in the EP group, but not in the LVIS group. The rate of moderate to severe in-stent stenosis was lower in the LVIS group (10.2%) than in the EP group (16.8%), but the difference was not statistically significant (P = 0.198). Our data show acceptable rates of complete and near-complete occlusion with both the LVIS and EP stents. LVIS stents were associated with lower rates of recanalization and in-stent stenosis, but the difference was not significant. Higher SR (≥2) was a significant predictor of recanalization in IAs treated with EP stents, but not in those treated with LVIS stents. Copyright © 2017. Published by Elsevier Inc.

  2. Endovascular treatment of ruptured true posterior communicating artery aneurysms.

    Science.gov (United States)

    Yang, Yonglin; Su, Wandong; Meng, Qinghai

    2015-01-01

    Although true posterior communicating artery (PCoA) aneurysms are rare, they are of vital importance. We reviewed 9 patients with this fatal disease, who were treated with endovascular embolization, and discussed the meaning of endovascular embolization for the treatment of true PCoA aneurysms. From September 2006 to May 2012, 9 patients with digital substraction angiography (DSA) confirmed true PCoA aneurysms were treated with endovascular embolization. Patients were followed-up with a minimal duration of 17 months and assessed by Glasgow Outcome Scale (GOS) score. All the patients presented with spontaneous subarachnoid hemorrhage from the ruptured aneurysms. The ratio of males to females was 1:2, and the average age of onset was 59.9 (ranging from 52 to 72) years. The preoperative Hunt-Hess grade scores were I to III. All patients had recovered satisfactorily. No permanent neurological deficits were left. Currently, endovascular embolization can be recommended as the top choice for the treatment of most true PCoA aneurysms, due to its advanced technique, especially the application of the stent-assisted coiling technique, combined with its advantage of mininal invasiveness and quick recovery. However, the choice of treatment methods should be based on the clinical and anatomical characteristics of the aneurysm and the skillfulness of the surgeon.

  3. A microfabricated microfluidic bioMEMS device to model human brain aneurisms: the aneurysm-on-a-chip

    Science.gov (United States)

    Reece, Lisa M.; Khor, Jian Wei; Thakur, Raviraj; Amin, Ahmed; Wereley, Steven T.; Leary, James F.

    2015-03-01

    Aneurysms are pockets of blood that collect outside blood vessel walls forming dilatations and leaving arterial walls very prone to rupture. There is little information concerning the causes of intracranial aneurysm formation, growth, and rupture. Current treatments include: (1) clipping, and (2) coil embolization, including stent-assisted coiling. Further, the evolution of any aneurysm is assumed to be caused by the remodeling of the affected blood vessel's material constituents (tunica intima, tunica media, or tunica adventitia). Velocity, pressure, and wall shear stresses aid in the disease development of aneurysmal growth, while the shear force mechanisms effecting wound closure are elusive. To study aneurysm pathogenesis, a lab-on-a-chip device is the key to discovering the underlying mechanisms of these lesions. A two-dimensional microfluidic model, the Aneurysm-on-a-Chip™ (AOC), was the logical answer to study particle flow within an aneurysm "sac". The AOC apparatus can track particles/cells when it is coupled to particle image velocimetry software (PIV) package. The AOC fluid flow was visualized using standard microscopy techniques with commercial microparticles and human aortic smooth muscle cells (HASMC). Images were taken during fluid flow experiments and PIV was utilized to monitor the flow of particles within the "sac" region, as well as particles entering and exiting the device. Quiver plots were generated from fluid flow experiments using standard 7 μm latex particles and fixed HASMC in PBS. PIV analysis shows that the particles flowed nicely from input to output. Wall shear stress provided evidence that there was some back flow at the edges of the "sac" - an indicator of aneurysm development in human patients.

  4. Unruptured medial paraclinoid internal carotid artery aneurysm embedded within symptomatic nonfunctioning pituitary giant adenoma: A high-risk comorbid pathology in transsphenoidal surgery and its countermeasures

    Directory of Open Access Journals (Sweden)

    Taiki Saito, M.D.

    2017-12-01

    Conclusions: This case conveys three important lessons about TSS: 1 coil embolization will manage a medial paraclinoid ICA-An as a sufficient preoperative procedure for TSS; 2 a medial paraclinoid ICA-An can appear directly under the sellar floor as an apparent extradural aneurysm; and; 3 surgeons should take great care in procedures near a coil-embolized medial paraclinoid ICA-An because the aneurysmal wall can be thin to the point of transparency.

  5. Abciximab in the treatment of acute in-stent thrombosis in patient with intracranial aneurysm

    International Nuclear Information System (INIS)

    Lilov, M.; Juszkat, R.; Petkov, A.; Todorov, I.

    2009-01-01

    A case of endovascular therapy via embolization of aneurysm in patient with SAH is performed selective brain angiography and find 3 aneurysms. The first is in right segment M1-M2 with diameter 5 mm, the second with wide neck is in supraclinoid portion of right internal carotid artery and the third in left M1-M2 segment. One month after embolization of ruptured aneurysm with coils BALT (Montmorency, France) and previous anticoagulation therapy was applied Leo stent (SALT) intraluminal in left internal carotid artery. Developed acute instent thrombosis recanalized with intraarterial use of abciximab. (authors)

  6. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  7. The Use of Flow Diverting Stents to Treat Para-Ophthalmic Aneurysms

    Directory of Open Access Journals (Sweden)

    Pervinder Bhogal

    2017-08-01

    Full Text Available Background and purposeFew publications have dealt exclusively with the use of flow diverter stents for the treatment of para-ophthalmic aneurysms. We sought to determine the efficacy of flow diverting stents (FDSs to treat aneurysms in this specific location.MethodsWe retrospectively reviewed our database of prospectively collected information for all patients treated with flow diversion for an unruptured saccular para-ophthalmic aneurysm between September 2009 and January 2016. The aneurysm fundus size, neck size, number and type of FDS, complications, and follow-up data were recorded.ResultsWe identified 74 patients that matched our inclusion criteria. Of these patients, 18 patients were male (24.3%. The average fundus size was 4.8 mm, 11 aneurysms had previous coil occlusions and 63 were treated solely with flow diversion. At an initial angiographic follow-up (mean avg. 3.2 months, 71.8% of the aneurysms were occluded, and at the last follow-up (mean avg. 31.8 months, 88.9% of aneurysms were occluded. One patient suffered permanent morbidity (1.36% secondary to interruption of the antiplatelet medication and another died (1.36% secondary to in-stent thrombosis that was also due to an interruption in the antiplatelet medication.ConclusionTreatment of saccular para-ophthalmic aneurysms with FDS is feasible and carries a high degree of technical success with low complication rates and excellent rates of aneurysm exclusion.

  8. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  9. An Unusual Aneurysm of the Main Pulmonary Artery Presenting as Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Kholeif, Mona A.; El Tahir, Mohamed; Kholeif, Yasser A.; El Watidy, Ahmed

    2006-01-01

    A 70-year old man presented with retrosternal chest pain. His electrocardiogram showed nonspecific T wave changes. Cardiac-specific troponin I (cTnI) was elevated. His condition was managed as acute coronary syndrome, following which he had two minor episodes of hemoptysis. A CT pulmonary angiogram showed no evidence of pulmonary embolism, but a large mass lesion was seen in the mediastinum. Echocardiography and cardiac MRI demonstrated a large solid mass, arising from the right ventricular outflow tract and causing compression of the main pulmonary artery (MPA). The differential diagnosis included pericardial and myocardial tumors and clotted aneurysm of the MPA. At surgery, a clotted aneurysmal sac was identified originating from the MPA and the defect was healed. Aneurysms of the MPA are rare. They most commonly present with dyspnea and chest pain. Compression of surrounding structures produces protean manifestations. A high index of suspicion coupled with imaging modalities establishes the diagnosis. Blunt trauma to the chest, at the time of an accident 4 years previously, may explain this aneurysm. The patient's presentation with chest pain was probably due to compression and/or stretching of surrounding structures. Coronary artery compression simulating acute coronary syndrome has been documented in the literature. The rise in cTnI may have been due to right ventricular strain, as a result of right ventricular outflow obstruction by the aneurysm. This has not been reported previously in the literature. The saccular morphology and narrow neck of the aneurysm predisposed to stagnation leading to clotting of the lumen and healing of the tear, which caused the diagnostic difficulty

  10. Percutaneous and Endovascular Embolization of Ruptured Hepatic Artery Aneurysm

    International Nuclear Information System (INIS)

    Little, Andrew F.; Lee, Wai Kit

    2002-01-01

    A 72-year-old woman presented with an intraperitoneal hemorrhage from a ruptured intrahepatic arteryaneurysm, with an associated pseudoaneurysm developing a high-flow arteriovenous fistula. Persistent coagulopathy and a median arcuate ligament stenosis of the celiac axis further complicated endovascular management. Aneurysm thrombosis required percutaneous embolization with coils, a removable core guidewire and polyvinyl alcohol particles

  11. Immediate CT findings following embolization of cerebral aneurysms: suggestion of blood-brain barrier or vascular permeability change

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Kim, Yong Sun; Lee, Hui Jung; Kim, Gab Chul; Park, Jaechan

    2008-01-01

    Although endovascular techniques are widely used for the treatment of cerebral aneurysms, the immediate postprocedural brain CT findings have not been reported. Therefore, in the present study we assessed the immediate postprocedural brain CT findings following the uneventful coil embolization of cerebral aneurysms. Included in the study were 59 patients with 61 cerebral aneurysms after uncomplicated coil embolization. Acute subarachnoid hemorrhage was present with 32 of the 61 aneurysms. All patients underwent a brain CT scan just before and within 2 h after the endovascular treatment. If the postprocedural CT scan revealed any new findings, a follow-up CT scan and/or MRI were performed within 24 h. The variables related to the abnormal CT findings were also evaluated. Among the 61 immediate brain CT scans, 26 (43%) showed abnormal findings, including cortical contrast enhancement (n=21, 34%), subarachnoid contrast enhancement (n=8, 13%), intraventricular contrast enhancement (n=5, 8%), and striatal contrast enhancement (n=2, 3%). Single or mixed CT findings were also seen. None of the 61 aneurysms was associated with new neurological symptoms after endovascular treatment, and all patients made an uneventful recovery. Abnormal findings were more likely to be found with lower body weight and with increased corrected amounts of contrast material and heparin (P<0.05). After uneventful endovascular treatment of cerebral aneurysms, the immediate brain CT findings can reveal various patterns of abnormal contrast enhancement. Recognizing the immediate brain CT findings is important, as they can mimic various diseases. (orig.)

  12. Endovascular management of a carotid aneurysm into the sphenoid sinus presenting with epistaxis.

    Science.gov (United States)

    Akkari, Mohamed; Gascou, Grégory; Trévillot, Vincent; Bonafé, Alain; Crampette, Louis; Machi, Paolo

    2015-12-01

    Non-traumatic cavernous internal carotid artery (ICA) aneurysms are rare, and favour the occurrence of massive recurrent epistaxis, which is associated with a high mortality rate. We report the case of a 67-year-old woman presenting a ruptured ICA aneurysm extending into the sphenoid sinus, revealed by epistaxis. Selective coil embolization of the aneurysm was performed. Flow-diverter stents were deployed in order to utterly exclude the aneurysm and prevent revascularization. Anti-platelet treatment was provided to lower the risk of in-stent thrombosis. A left frontal hematoma associated with a subarachnoid haemorrhage occurred at day 2. Outcome was favourable with no neurological sequelae, and no clinical recurrence of epistaxis occurred. A 4 months follow-up digital subtraction angiography showed a complete exclusion of the aneurysm. In addition, a magnetic resonance cerebral angiography at 16 months showed stable results. Thus, this two-stage endovascular procedure has proven its effectiveness in preventing epistaxis recurrence while preserving the ICA patency. © The Author(s) 2015.

  13. The Woven EndoBridge (WEB) as primary treatment for unruptured intracranial aneurysms.

    Science.gov (United States)

    van Rooij, Sanne Bt; van Rooij, Willem Jan; Peluso, Jo P; Sluzewski, Menno

    2018-01-01

    Purpose The intrasaccular flow disruptor Woven EndoBridge (WEB) device is developed for the treatment of wide-necked aneurysms without supportive devices. We used the WEB as primary treatment for unruptured aneurysms suitable for the device, regardless of neck size. Methods Between February 2015 and June 2017, 59 aneurysms in 51 patients were selectively treated with the WEB. There were 15 men and 36 women with a mean age of 59 years. Mean aneurysm size was 7.0 mm (range 3-22 mm). Of 59 aneurysms, 45 (76%) had a wide neck defined as ≥4 mm or dome-neck ratio ≤1.5. No stents or supporting balloons were used. Results Initial WEB position was judged good in all 59 unruptured aneurysms. One patient with a basilar tip aneurysm had a late thrombotic posterior cerebral artery occlusion by protrusion of the WEB over the artery. There were no procedural ruptures. Overall complication rate was 2.0% (1 of 51, 95% CI 0.01-11.3%). Imaging follow-up was available in 55 of 59 aneurysms (93%). At 3 months, 41 of 57 aneurysms (72%) were completely occluded, 12 (21%) had a neck remnant and 4 (7%) were incompletely occluded. Conclusion WEB treatment is safe and effective in selected unruptured aneurysms suitable for the device, regardless of neck size or location. There was no need for supportive devices. Three-quarters of all unruptured small aneurysms could be treated with the WEB. In our opinion, the WEB is a valuable alternative to coils, especially in wide-necked aneurysms.

  14. Delayed massive epistaxis from traumatic cavernous carotid false aneurysms: A report of two unusual cases.

    Science.gov (United States)

    Mankahla, Ncedile; LeFeuvre, David; Taylor, Allan

    2017-08-01

    Introduction Blunt head trauma can injure the cavernous segment of the internal carotid artery (ICA). This may result in a carotid cavernous fistula (CCF). Rarely, a traumatic aneurysm may bleed medially causing massive epistaxis. Case presentation We present two cases of traumatic intracavernous carotid pseudoaneurysms with delayed massive epistaxis. The patients were managed with endovascular treatment involving coil embolization with parent vessel sparing and detachable balloon occlusion with carotid sacrifice. Early clinical outcome was good in both patients. Wherever possible, the CARE 1 guidelines were followed in the reporting. Conclusion These cases illustrate the delayed nature of traumatic aneurysms and the need for a high index of suspicion in the presence of skull base fractures. The use of endovascular detachable balloon occlusion and coil embolization treatment with parent vessel preservation is shown.

  15. Mycotic aneurysms : radiological diagnosis and therapeutic alternatives

    International Nuclear Information System (INIS)

    Urbano, J.; Arjonilla, M. A.

    2002-01-01

    To review mycotic aneurysms, their radiological diagnosis and therapeutic alternatives. Five men and a woman between 69 and 84 years old were diagnosed during the last 4 years with mycotic aneurysms. Three were in the aorta, one in the thoracic and two in the abdominal region; one was affecting the left primitive iliac artery, another the left popliteal artery and, in the last case, the medial cerebral artery. Hemo cultures were done on all patients. The surgical specimen was cultivated in 4. CAT was done on 5 patients, angiography on another five and Doppler ultrasound scan on two. Five patients showed positive hemo cultures and in two the surgical specimen culture was positive. The findings of the CAT were decisive in being able to suspect that the lesions were mycotic in nature. Three patients had to undergo emergency, expiring either in surgery or in postoperative care. One case was treated by means of aortic endo prosthesis, and one year later the patient remains asymptomatic. The cerebral aneurysm was embolized with metal coils and the patient remains asymptomatic three years later. The popliteal aneurysm underwent surgical intervention using an established protocol with good results. CAT is decisive in the diagnosis of mycotic aneurysms. Once detected, they must be treated without delay as their natural evolution is one of rapid expansion and rupture. Angiographies help in planning the treatment. Radiological intervention plays an important role in the treatment. (Author) 13 refs

  16. Transcatheter Coil Embolization of an Aneurysm of the Pancreatico-duodenal Artery with Occluded Celiac Trunk

    International Nuclear Information System (INIS)

    Weber, C.H.; Pfeifer, K.J.; Tato, F.; Reiser, M.; Rieger, J.

    2005-01-01

    We report on a case of a wide-necked aneurysm of the pancreatico-duodenal artery with occlusion of the celiac trunk in an asymptomatic patient. The aneurysm was considered to be at high risk of rupture. Successful embolization after interdisciplinary consultation was followed with color-coded duplex ultrasound (CCDS) demonstrating significant flow reduction. Three weeks later CCDS and angiography demonstrated exclusion of the aneurysm and a patent arterial supply of the liver and spleen fed by superior mesenteric artery (SMA) collaterals. The patient has done well so far, without major adverse clinical events or evidence for tissue necrosis of the liver, pancreas or spleen. Discussion of the case and review of the literature indicate that transcatheter embolization is the therapy of choice even in complicated cases

  17. Visceral artery aneurysms and pseudoaneurysms. Retrospective analysis of interventional endovascular therapy of 43 aneurysms; Aneurysmen und Pseudoaneurysmen viszeraler Arterien. Retrospektive Analyse der interventionellen radiologischen Therapie von 43 Aneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Ruhnke, Hannes; Kroencke, Thomas J. [Klinikum Augsburg (Germany). Dept. of Diagnostic and Interventional Radiology and Neuroradiology

    2017-07-15

    To evaluate the results of interventional endovascular therapy of incidental and symptomatic visceral artery aneurysms in the elective and emergency situation. 43 aneurysms in 38 patients (19 female, 19 male, mean age: 57 ± 16 years [18-82]) were treated between 2011 and 2015. The characteristics of the aneurysms (true vs. false aneurysm, size, etiology, location, symptoms) were considered. Furthermore, we evaluated the intervention with respect to technical success, embolic/occlusive agents used, therapy-associated complications and post-interventional follow-up. 23 true aneurysms (maximum diameter: 22 ± 18 mm [11 - 67mm]) and 20 false aneurysms (maximum diameter: 9 ± 33 mm [3 - 150 mm]) were evaluated. The splenic (n = 14) and renal arteries (n = 18) were most frequently affected. The etiology was most commonly degenerative-atherosclerotic (47%) or iatrogenic post-operative (19%). 18/48 interventions were performed due to active bleeding. False aneurysms were associated significantly more often with active bleeding (63 vs. 25%, p = 0.012). 41/48 treatments were technically successful. Re-intervention was necessary 6 times. In 2 cases the endovascular approach did not succeed. There was a complication rate of 10%, whereby only 4 minor and 1 major complications occurred. No patient suffered from permanent sequelae. Aneurysms were primarily treated by using coils and if necessary additional embolic agents (liquid embolic agent or vascular plugs) (75%). In the follow-up period, reperfusion of treated aneurysms occurred at a rate of 7% (n = 3). Interventional endovascular therapy of visceral artery aneurysms is safe and effective in the elective treatment of incidental aneurysms as well as in significantly more frequent hemorrhaging false aneurysms in the emergency situation.

  18. Delayed pan-hypopituitarism as a complication following endovascular treatment of bilateral internal carotid artery aneurysms. A case report and review.

    Science.gov (United States)

    Hall, Jonathan; Caputo, Carmela; Chung, Carlos; Holt, Michael; Wang, Yi Yuen

    2015-04-01

    Pan-hypopituitarism has been reported in patients who are subsequently found to have a cerebral aneurysm and there have been reports of pituitary dysfunction immediately following both surgical and endovascular treatment. The authors report a rare case of delayed pan-hypopituitarism following endovascular treatment of bilateral internal carotid artery aneurysms with coil embolisation and flow-diverting stents.

  19. Treatment Challenges of a Primary Vertebral Artery Aneurysm Causing Recurrent Ischemic Strokes

    Directory of Open Access Journals (Sweden)

    Davide Strambo

    2017-01-01

    Full Text Available Background. Extracranial vertebral artery aneurysms are a rare cause of embolic stroke; surgical and endovascular therapy options are debated and long-term complication may occur. Case Report. A 53-year-old man affected by neurofibromatosis type 1 (NF1 came to our attention for recurrent vertebrobasilar embolic strokes, caused by a primary giant, partially thrombosed, fusiform aneurysm of the left extracranial vertebral artery. The aneurysm was treated by endovascular approach through deposition of Guglielmi Detachable Coils in the proximal segment of the left vertebral artery. Six years later the patient presented stroke recurrence. Cerebral angiography and Color Doppler Ultrasound well characterized the unique hemodynamic condition developed over the years responsible for the new embolic event: the aneurysm had been revascularized from its distal portion by reverse blood flow coming from the patent vertebrobasilar axis. A biphasic Doppler signal in the left vertebral artery revealed a peculiar behavior of the blood flow, alternately directed to the aneurysm and backwards to the basilar artery. Surgical ligation of the distal left vertebral artery and excision of the aneurysm were thus performed. Conclusion. This is the first described case of NF1-associated extracranial vertebral artery aneurysm presenting with recurrent embolic stroke. Complete exclusion of the aneurysm from the blood circulation is advisable to achieve full resolution of the embolic source.

  20. Successful Transarterial Embolization of a Posttraumatic Fistula Between a Posterior Communicating Artery Aneurysm and the Cavernous Sinus: A Case Report.

    Science.gov (United States)

    Jinbo, Yin; Jun, Liu; Kejie, Mou; Zheng, Zhou

    2015-01-01

    Posterior communicating artery (PCoA) aneurysm-cavernous sinus fistulae are an extremely rare complication of head injury . The treatment of PCoA aneurysm-cavernous sinus fistulae has not been well described. A 27-year-old man was admitted with a retroocular bruit and blurred vision of the left eye seven months after a severe head injury. We report the angiographic appearance of a posterior communicating artery (PCoA) aneurysm with a fistula to the cavernous sinus. This injury had been previously misinterpreted to be a PCoA aneurysm by computerized tomographic angiography (CTA). The patient was successfully treated with coils and Onyx of a fistula between the PCoA aneurysm and cavernous sinus.

  1. Outcome of emergency endovascular treatment of large internal iliac artery aneurysms with guidewires

    International Nuclear Information System (INIS)

    Cambj-Sapunar, Liana; Maskovic, Josip; Brkljacic, Boris; Radonic, Vedran; Dragicevic, Dragan; Ajduk, Marko

    2010-01-01

    Purpose: Guidewires have been reported as a useful occlusion material for large aneurysms of different locations with good short-term results. In this study we retrospectively evaluate long-term results of emergency embolization technique with guidewires in symptomatic internal iliac artery aneurysm (IIAA) impending rupture. Patients and methods: In four patients presented with acute abdominal pain, multidetector computed tomography revealed unstable, 7-14 cm large, IIAAs. Two patients were treated with coil embolization of distal branches followed by occlusion of aneurysmal sac with guidewires. In two patients embolization of aneurysmal sac alone was performed. Results: In three patients complete or near complete occlusion of the aneurysmal sac was achieved and abdominal pain ceased within hours. Two patients treated with embolization of distal iliac artery branches and aneurysmal sac developed claudication that lasted up to 1 year. Their aneurysms remained thrombosed and they were without symptoms until they died 31 and 56 months later of causes unrelated to IIAA. Two patients treated with embolization of the aneurysm alone were free of ischemic symptoms. Because of incomplete embolization of the sac in one patient open surgery treatment in a non-emergency setting was performed. Complete filling of aneurysmal sac was achieved in other patient but 2 years later his aneurysm re-opened and required open surgery treatment. Conclusion: Embolization of aneurysmal sac of large IIAA with guidewires may be effective for immediate treatment of impending rupture. Long-term results were better when embolization of the aneurysmal sac was combined with embolization of distal IIA branches.

  2. Recanalization of Splenic Artery Aneurysm After Transcatheter Arterial Embolization Using N-Butyl Cyanoacrylate

    International Nuclear Information System (INIS)

    Matsumoto, Keiji; Ushijima, Yasuhiro; Tajima, Tsuyoshi; Nishie, Akihiro; Hirakawa, Masakazu; Ishigami, Kousei; Yamaji, Yukiko; Honda, Hiroshi

    2010-01-01

    A 65-year-old woman who had been diagnosed as having microscopic polyangiitis developed sudden abdominal pain and entered a state of shock. Abdominal CT showed massive hemoperitoneum, and emergent angiography revealed a ruptured splenic artery aneurysm. After direct catheterization attempts failed due to tortuous vessels and angiospasm, transcatheter arterial embolization using an n-butyl cyanoacrylate (NBCA)-lipiodol mixture was successfully performed. Fifty days later, the patient developed sudden abdominal pain again. Repeated angiography demonstrated recanalization of the splenic artery and splenic artery aneurysm. This time, the recanalized aneurysm was embolized using metallic coils with the isolation method. Physicians should keep in mind that recanalization can occur after transcatheter arterial embolization using N-butyl cyanoacrylate, which has been used as a permanent embolic agent.

  3. Hepatic Artery Mycotic Aneurysm Associated with Staphylococcal Endocarditis with Successful Treatment: Case Report with Review of the Literature

    Directory of Open Access Journals (Sweden)

    Dhara Chaudhari

    2013-01-01

    Full Text Available Mycotic hepatic artery aneurysm is a vascular pathology associated with bacterial endocarditis. It is rare in occurrence after the introduction of effective antibiotics. We present a young patient with injection drug abuse associated staphylococcal endocarditis which was successfully treated with antibiotics and valve replacement who presented with abdominal pain. He was found to have mycotic aneurysm of hepatic artery which was successfully treated with coil embolization.

  4. Methods and time schedule for follow-up of intracranial aneurysms treated with endovascular embolization: a systematic review.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2011-01-01

    To review the diagnostic value of angiographic methods and the optimal timetable for follow-up imaging of patients after endovascular treatment of intracranial aneurysms. A comprehensive computer-aided search for relevant primary papers was performed using the MEDLINE, PubMed, Embase, and Cochrane Collaboration database from January 1991 to March 2011. Original papers were included that reported either diagnostic value of angiographic modalities for follow-up vs. digital subtracted angiography (DSA) or comparison of aneurysm occlusion rate in delayed vs. early follow-up. The systematic review identified 35 relevant studies: 3 on the diagnostic value of three-dimensional (3D) DSA, 30 on the performance of magnetic resonance angiography (MRA), and 3 on time schedules for follow-up. 3D DSA had sensitivity of 100%, and specificity of 58.3-94.7%. Magnetic resonance angiography had sensitivity of 28.4-100%, and specificity of 50.0-100%. The proportion of aneurysms that recanalized between the early follow-up examination at 6 months and the delayed imaging at 1.5-6.0 years was 0-2.5%. Magnetic resonance angiography seems to be the best imaging method for the follow-up. In selected cases, when invasive angiography is necessary, 3D DSA should be considered to improve the diagnostic accuracy. Most patients who present with stable and adequate aneurysm occlusion at 6 months after coiling may not require further follow-up. Key words: intracranial aneurysm, embolization, coils, digital subtracted angiography, magnetic resonance, computed tomography.

  5. Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    Hagspiel, Klaus D.; Bonatti, Hugo; Sabri, Saher; Arslan, Bulent; Harthun, Nancy L.

    2011-01-01

    Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

  6. Late-Onset Massive Epistaxis due to a Ruptured Traumatic Internal Carotid Artery Aneurysm: A Case Report.

    Science.gov (United States)

    Arai, Nobuhiko; Nakamura, Akiyoshi; Tabuse, Masanao; Miyazaki, Hiromichi

    2017-01-01

    A traumatic internal carotid artery (ICA) aneurysm is rare and difficult to treat. Trapping of ICA is commonly performed owing to the difficulty of directly approaching ICA aneurysms. Recently, coiling the aneurysm itself was recommended if possible. However, it is controversial which of methods are best to completely treat aneurysm. We present the case of a 74-year-old man, who had experienced a head injury 8 years previously, with recurrent severe epistaxis. An ICA aneurysm was detected on computed tomography. The trapping and bypass was planned. However, sudden epistaxis occurred, we performed trapping to stop the bleeding and save his life. After the operation, no right ICA or aneurysm was detected. However, severe epistaxis recurred two months after the operation. In the second operation, a ligation of the common -/- external carotid artery and a severance of an ICA portion between the ophthalmic artery and the aneurysm were insufficient to stop the bleeding. This case indicates ICA trapping, even if a trapping portion is below an ophthalmic artery, is insufficient to treat an ICA aneurysm. ICA aneurysms should be suspected when a patient present with recurrent -/- massive epistaxis, who has a head injury history, even if it is far past.

  7. Endovascular treatment of ruptured splenic artery aneurysm

    DEFF Research Database (Denmark)

    Bjerring, Ole Steen

    2008-01-01

    Splenic artery aneurysms (SAA) are traditionally treated surgically, but endovascular techniques are becoming increasingly popular. A 64 year-old male with chest pain and low blood pressure was admitted under suspicion of AMI. A CT scan showed a 56 mm SAA with signs of rupture. The patient...... was treated with endovascular embolisation of the SAA with coils. Blood pressure and haemoglobin levels were stabilized and the patient was discharged. In the case of rupture the treatment of choice seems to be endovascular....

  8. Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Angelo; Byrne, James V. [ohn Radcliffe Hospital, Oxford Neurovascular and Neuroradiology Research Unit, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); Rane, Neil; Kueker, Wilhelm; Cellerini, Martino; Corkill, Rufus [John Radcliffe Hospital, Department of Neuroradiology, Oxford (United Kingdom)

    2014-01-15

    This study assessed volume changes of unruptured large and giant aneurysms (greatest diameter >20 mm) after treatment with flow diverter (FD) stents. Clinical audit of the cases treated in a single institution, over a 5-year period. Demographic and clinical data were retrospectively collected from the hospital records. Aneurysm volumes were measured by manual outlining at sequential slices using computerised tomography (CT) or magnetic resonance (MR) angiography data. The audit included eight patients (seven females) with eight aneurysms. Four aneurysms involved the cavernous segment of the internal carotid artery (ICA), three the supraclinoid ICA and one the basilar artery. Seven patients presented with signs and symptoms of mass effect and one with seizures. All but one aneurysm was treated with a single FD stent; six aneurysms were also coiled (either before or simultaneously with FD placement). Minimum follow-up time was 6 months (mean 20 months). At follow-up, three aneurysms decreased in size, three were unchanged and two increased. Both aneurysms that increased in size showed persistent endosaccular flow at follow-up MR; in one case, failure was attributed to suboptimal position of the stent; in the other case, it was attributed to persistence of a side branch originating from the aneurysm (similar to the endoleak phenomenon of aortic aneurysms). At follow-up, five aneurysms were completely occluded; none of these increased in volume. Complete occlusion of the aneurysms leads, in most cases, to its shrinkage. In cases of late aneurysm growth or regrowth, consideration should be given to possible endoleak as the cause. (orig.)

  9. Bleeding aneurysms of the celiac trunk

    International Nuclear Information System (INIS)

    Ziviello, M.; D'Isa, L.; Siani, A.; Maglione, F.; Cataldo, B.; Ziviello, R.; Capalbogiliberti, R.

    1988-01-01

    The authors report their experience in the study of bleeding aneurysms of the celiac arteries. Eleven patients were examined with US,CT, and angiography (8 hepatic artery aneurysms and 3 splenic artery aneurysms). Clinical findings included digestive bleeding, upper abdominal pain, palpable pulsating masses, and jaundice. Patient history included blunt abdominal trauma, penetrating trauma due to gunshot, acute pancreatitis, recent hepatic biospy. In all cases US showed an abdominal mass ranging in size from 2 to 10 cm. US findings included cyst-like lesions (8 cases), anobulated solid-like lesion, and complex lesion (2 cases). Continuity of the lesion with adjancent arterial vessels was noted in 5/11 cases, and pulsing activity in 3/11 cases. US patterns, although not specific, play an important role in the diagnosis when associated to other elements such as arterial continuity, mass pulsatility, patient history, and gastrointestinal bleeding. They suggest the need for more specific imaging exams, i.e. CT and angiography, and help avoid dangerous diagnostic biopsies. CT was performed to confirm US findings in 5 cases, and detected either hypodense cystic masses, or inhomogeneous masses with arterial enhancement after bolus injection of cm. CT was used to better demonstrate the lumen, patency of the vessel, the walls of the vessel, and the parietal thrombotic component. The typical arterial enhancement was the decisive finding for the diagnosis, even though a total continuity with arterial vessels was never observed. Angiography was the method of choice for the preoperative demonstration of hepatic artery aneurysms (10 cases) and for occlusive treatment with Gianturco coils (3 cases)

  10. Endovascular therapy of abdominal aortic aneurysm: results of a mid-term follow-up

    International Nuclear Information System (INIS)

    Pitton, M.B.; Schweitzer, H.; Herber, S.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2003-01-01

    Prospective study to evaluate clinical results and complications of endovascular abdominal aortic aneurysm treatment in a mid-term follow-up. Materials and methods: A total of 122 patients (9 females, 113 males, average age 70.0±7,9 years) with abdominal aortic aneurysms were treated with stent grafts (53 Vanguard or Stentor endografts, 69 Talent endografts). Group I consisted of 40 patients who had all aortic tributaries of the aneurysm sac occluded prior to endovalscular grafting, either spontaneously by parietal thrombosis or by selective coil embolization of the respective ostia preserving collateral circulation distal to the vessel occlusion. Group II consisted of 82 patients and included all cases without or with incomplete coil embolization with at least one patent vessel. Stent grafting was performed in general anesthesia in the first 21 patients, followed by peridural anesthesia in 15 cases, and local anesthesia with conscious sedation in 86 cases. The results were evaluated with Spiral-CT, MRI and radiographs of the endovascular graft, with follow-up examinations obtained at 3, 6, 12 months, and every year - Implantation was successfully completed in all cases without primary conversion surgery, laparotomy or any significant complication. Mean follow-up was 29±21 months (maximum 82 months). The 30-day mortality was 0,8% due to a myocardial infarction 3 days after discharge from the hospital. A total of 47 re-interventions were performed in 29 patients (23.8%), with 35 re-interventions in 18 cases with Vanguard or Stentor endografts and 12 re-interventions in 11 patients with Talent endografts. 23 percutaneous re-interventions included distal graft extension (n=11), Wallstent for kinking and limb stenosis (n=3), and secondary coil embolization of collateral vessels (n=9). 24 surgical re-interventions included proximal graft extension (n=6), new endovascular grafts (n=3), surgical clipping of lumbar and mesenteric artery branches for type-II endoleaks

  11. Lethal Ultra-Early Subarachnoid Hemorrhage Due to Rupture of De Novo Aneurysm 5 Months After Primary Aneurysmatic Subarachnoid Hemorrhage.

    Science.gov (United States)

    Walter, Johannes; Unterberg, Andreas W; Zweckberger, Klaus

    2018-05-01

    Approximately 1% of all patients surviving rupture of a cerebral aneurysm suffer from a second aneurysmatic subarachnoid hemorrhage later in their lives, 61% of which are caused by rupture of a de novo aneurysm. Latency between bleedings is usually many years, and younger patients tend to achieve better outcomes from a second subarachnoid hemorrhage. We report an unusual case of lethal ultra-early rupture of a de novo aneurysm of the anterior communicating artery only 5 months after the initial subarachnoid hemorrhage and complete coiling in a young, healthy male patient. Despite complete aneurysm obliteration, young age, and good recovery, patients may be subjected to secondary subarachnoid hemorrhages from de novo aneurysms after only a few months of the initial bleeding. Early-control magnetic resonance angiography might hence be advisable. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Rasmussen's aneurysm: A rare and forgotten cause of hemoptysis

    Directory of Open Access Journals (Sweden)

    Rakesh Sapra

    2015-12-01

    Full Text Available Hemoptysis as a sequelae of past tubercular infection of lungs is a known occurrence. Hemoptysis in such a patient can result from a number of etiologies like tubercular reactivation, bronchiectasis, aspergiloma and vascular complications like hypervascularity from bronchial arteries, arteriovenous fistula formation, pseudoaneurysms, etc. Massive hemoptysis in such a patient is usually treated by bronchial artery embolization and occasionally by surgical lobectomy. A rare source of bleeding in such a patient is from Rasmussen's aneurysm arising from the pulmonary arteries. We report a young patient of treated pulmonary tuberculosis who had recurrent hemoptysis. He was treated earlier with bronchial artery embolization. On recurrence of hemoptysis, he was reevaluated and was found to have multiple Rasmussen's aneurysms arising from the pulmonary arteries, which were successfully treated by coil embolization.

  13. The use of novel flow diverting device Tubridge for the treatment of intracranial aneurysms: initial experience

    International Nuclear Information System (INIS)

    Yang Pengfei; Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo; Zhao Wenyuan; Li Qiang; Fang Yibin; Zhang Yuhui

    2011-01-01

    Objective: To preliminarily evaluate the feasibility, efficacy and safety of the novel flow diverting device, Tubridge, in treating intracranial aneurysms. Methods: The novel flow diverting device, Tubridge, was employed to treat intracranial aneurysms in 14 patients with a mean age of (52.4±10.2) years. A total of 14 intracranial aneurysms were detected in 14 patients, including 13 un-ruptured aneurysms and one ruptured aneurysms. The technical results and clinical data were analyzed. Results: A total of 18 flow diverters were implanted. The flow diverter was successfully conveyed and delivered in all patients, with a technical success rate of 100%. Six aneurysms were treated with the flow diverter together with the coils. Of the six aneurysms, complete obliteration of the aneurysm was obtained in 2 (Raymond grade Ⅰ), remnant of neck was seen in 1 (Raymond grade Ⅱ) and residual aneurysm sac was found in 3 (Raymond grade Ⅲ) cases. Eight aneurysms were treated with flow diverter implantation alone. After the procedure, marked decrease in contrast filling of the aneurysm sac was seen in 3 aneurysms, while the change in contrast filling pattern of the aneurysm sac as well as the obvious retention of contrast in the aneurysm sac could be detected in all cases. No procedure-related hemorrhagic or ischemic complications occurred. The mRS score at the time of discharge was 0 (n=13) or 1 (n=1). Conclusion: For the treatment of some special type intracranial aneurysms, the use of Tubridge flow diverter is clinically feasible, its effect is immediate and satisfactory with higher safety in short term. However, its long-term efficacy and safety need to be further evaluated. (authors)

  14. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N.; Atar, Eli

    2009-01-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

  15. The New Low-Profile WEB 17 System for Treatment of Intracranial Aneurysms: First Clinical Experiences.

    Science.gov (United States)

    van Rooij, S B T; Peluso, J P; Sluzewski, M; Kortman, H G; van Rooij, W J

    2018-05-01

    The Woven EndoBridge (WEB) is an intrasaccular flow diverter intended to treat wide-neck aneurysms. The latest generation WEBs needed a 0.021-inch microcatheter in the small sizes. Recently, a lower profile range of WEBs compliant with a 0.017-inch microcatheter (WEB 17) has been introduced. We present the first clinical results of treatment of both ruptured and unruptured aneurysms with the WEB 17. Between December 2016 and September 2017, forty-six aneurysms in 40 patients were treated with the WEB 17. No supporting stents or balloons were used. Twenty-five aneurysms were ruptured (54%). There were 6 men and 34 women (mean age, 62 years; median, 63 years; range, 46-87 years). The mean aneurysm size was 4.9 mm (median, 5 mm; range, 2-7 mm). There were 2 thromboembolic procedural complications without clinical sequelae and no ruptures. The overall permanent procedural complication rate was 0% (0 of 40; 97.5% CI, 0%-10.4%). Imaging follow-up at 3 months was available in 33 patients with 39 aneurysms (97.5% of 40 eligible aneurysms). In 1 aneurysm, the detached WEB was undersized and the remnant was additionally treated with coils after 1 week. This same aneurysm reopened at 3 months and was again treated with a second WEB. One other aneurysm showed persistent WEB filling at 3 months. Complete occlusion was achieved in 28 of 39 aneurysms (72%), and 9 aneurysms (23%) showed a neck remnant. The WEB 17 is safe and effective for both ruptured and unruptured aneurysms. The WEB 17 is a valuable addition to the existing WEB size range, especially for very small aneurysms. © 2018 by American Journal of Neuroradiology.

  16. Reconstructive endovascular treatment of vertebral artery dissecting aneurysms with the Low-profile Visualized Intraluminal Support (LVIS device.

    Directory of Open Access Journals (Sweden)

    Chuan-Chuan Wang

    Full Text Available The Low-profile Visualized Intraluminal Support (LVIS device is a new generation of self-expanding braided stent recently introduced in China for stent assisted coiling of intracranial aneurysms. The aim of our study is to evaluate the feasibility, safety, and efficacy of the LVIS device in reconstructive treatment of vertebral artery dissecting aneurysms (VADAs.We retrospectively reviewed the neurointerventional database of our institution from June 2014 to May 2016. Patients who underwent endovascular treatment of VADAs with LVIS stents were included in this study. Clinical presentation, aneurysmal characteristics, technical feasibility, procedural complications, and angiographic and clinical follow-up results were evaluated.38 patients with VADAs who underwent treatment with LVIS stent were identified, including 3 ruptured VADAs. All VADAs were successfully treated with reconstructive techniques including the stent-assisted coiling (n = 34 and stenting only (n = 4. Post-procedural complications developed in 3 patients (7.9% including two small brainstem infarctions and one delayed thromboembolic event. Complications resulted in one case of minor permanent morbidity (2.6%. There was no procedure-related mortality. The follow-up angiogram was available in 30 patients at an average of 8.3 months (range, 2 to 30 months, which revealed complete occlusion in 23 patients (76.7%, residual neck in five patients (16.7%, and residual sac in two patients (6.7%. The follow-up of 25 aneurysms with incomplete immediate occlusion revealed 22 aneurysms (88% with improvement in the Raymond class. One aneurysm (3.3% showed recanalization and required retreatment. Clinical followed-up at 5-28 months (mean 14.1 months was achieved in 36 patients because two patients died of pancreatic cancer and basal ganglia hemorrhage, respectively. No new neurologic deterioration or aneurysm (rebleeding was observed.Our preliminary experience with reconstruction of VADAs with

  17. Treatment of ruptured intracranial aneurysms: implications of the ISAT on clipping versus coiling

    NARCIS (Netherlands)

    van den Berg, R.; Rinkel, G. J. E.; Vandertop, W. P.

    2003-01-01

    Patients with a ruptured intracranial aneurysm should be treated as soon as possible after the haemorrhage to prevent rebleeding and to allow vigorous treatment of ischemic events in case of vasospasm. The choice of treatment, endovascular or surgical, should be based on the angio-architectural

  18. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    International Nuclear Information System (INIS)

    Coupe, Nicholas J.; Ling, Lynn; Cowling, Mark G.; Asquith, John R.; Hopkinson, Gregory B.

    2009-01-01

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

  19. Unruptured internal carotid artery bifurcation aneurysms: general features and overall results after modern treatment.

    Science.gov (United States)

    La Pira, Biagia; Brinjikji, Waleed; Burrows, Anthony M; Cloft, Harry J; Vine, Roanna L; Lanzino, Giuseppe

    2016-11-01

    Internal carotid artery bifurcation aneurysms (ICAbifAs) present unique challenges to endovascular and surgical operators, and little is known about their natural history. We reviewed our institution's experience with ICAbifAs studying outcomes of surgical and endovascular management and natural history. Consecutive patients with unruptured ICAbifAs evaluated and/or treated over an 8-year interval were studied. Baseline demographics, neurovascular risk factors, aneurysm location and size, clinical presentation, treatment recommendations, and outcomes were prospectively collected and retrospectively analyzed. Continuous variables were compared with Student's t test and categorical variables with Chi-square tests. Fifty-nine patients with 61 unruptured ICAbifAs were included. Seven aneurysms were treated surgically (11.5 %), 22 underwent endovascular treatment (36 %), and 32 were managed conservatively (52.5 %). In the surgical group, short- and long-term complete aneurysm occlusion rates were 100 % with no cases of perioperative or long-term permanent morbidity or treatment-related mortality. In the endovascular group, two patients (11.7 %) with giant aneurysms had perioperative thromboembolic events with transient morbidity. There was one case of aneurysm rupture at follow-up in a giant aneurysm treated with partial coil embolization. Complete/near-complete occlusion rates were 63 %. There was one case of aneurysm rupture after 114 aneurysm-years of follow-up in the conservative management group (0.89 %/year), but no ruptures were observed in small aneurysms selected for conservative management. Unruptured small ICAbifAs have a benign natural history. In patients selected for treatment, excellent results can be achieved in the vast majority of patients with judicious use of endovascular and surgical therapy.

  20. Post-Treatment Hemodynamics of a Basilar Aneurysm and Bifurcation

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, J; Hartman, J; Rodriguez, J; Maitland, D

    2008-01-16

    Aneurysm re-growth and rupture can sometimes unexpectedly occur following treatment procedures that were initially considered to be successful at the time of treatment and post-operative angiography. In some cases, this can be attributed to surgical clip slippage or endovascular coil compaction. However, there are other cases in which the treatment devices function properly. In these instances, the subsequent complications are due to other factors, perhaps one of which is the post-treatment hemodynamic stress. To investigate whether or not a treatment procedure can subject the parent artery to harmful hemodynamic stresses, computational fluid dynamics simulations are performed on a patient-specific basilar aneurysm and bifurcation before and after a virtual endovascular treatment. The simulations demonstrate that the treatment procedure produces a substantial increase in the wall shear stress. Analysis of the post-treatment flow field indicates that the increase in wall shear stress is due to the impingement of the basilar artery flow upon the aneurysm filling material and to the close proximity of a vortex tube to the artery wall. Calculation of the time-averaged wall shear stress shows that there is a region of the artery exposed to a level of wall shear stress that can cause severe damage to endothelial cells. The results of this study demonstrate that it is possible for a treatment procedure, which successfully excludes the aneurysm from the vascular system and leaves no aneurysm neck remnant, to elevate the hemodynamic stresses to levels that are injurious to the immediately adjacent vessel wall.

  1. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  2. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  3. Predictors of shunt-dependent hydrocephalus following aneurysmal subarachnoid hemorrhage: a pilot study in a single Egyptian institute.

    Science.gov (United States)

    Aboul-Ela, Hashem M; Salah El-Din, Ahmed M; Zaater, Ahmed A; Shehab, Mohamed; El Shahawy, Ossama A

    2018-01-01

    Acute hydrocephalus can cause neurological deterioration after aneurysmal subarachnoid hemorrhage (aSAH). Predicting which patient would require shunting is challenging. This prospective study was conducted upon twenty patients who suffered acute hydrocephalus due to subarachnoid hemorrhage of ruptured aneurysms. Surgical or non-surgical management of hydrocephalus was conducted. Glasgow Coma scale (GCS) was assessed, and hydrocephalus was graded by bicaudate index. Fisher grade was determined from CT scan. Aneurysm site was determined by conventional or CT angiography. Either surgical clipping or endovascular coiling of aneurysms was performed. Initially, 3 (15%) patients had emergency CSF diversion on admission due to poor GCS on arrival. Initially, the remaining 17 patients were managed conservatively. Five patients did not require any intervention. Twelve patients had external ventricular drainage placement, 4 were weaned, and 8 failed weaning. High bicaudate index (> 0.2) correlated with shunting. Aneurysm site correlated well with shunting (ACoA or PCoA). Patients with fair GCS can be managed conservatively. Any deterioration warrants shifting to CSF diversion. Higher bicaudate index will usually need CSF diversion. The value of Fisher carries no significant value. Aneurysm location (ACoA or PCoA) correlates with an increased incidence of ventriculoperitoneal shunt placement.

  4. Ruptured intracranial aneurysm in patients with osteogenesis imperfecta: 2 familial cases and a systematic review of the literature.

    Science.gov (United States)

    Gaberel, T; Rochey, A; di Palma, C; Lucas, F; Touze, E; Emery, E

    2016-12-01

    Osteogenesis imperfecta is an inherited connective tissue disorder that causes bone fragility. Vascular complications have been described, but only few cases of ruptured intracranial aneurysm have been reported. We first described 2 familial cases of ruptured intracranial aneurysm and then conducted a systematic review of the literature. A mother and her daughter with a typical history of osteogenesis imperfecta presented with subarachnoid hemorrhage, which was related to a posterior communicating artery aneurysm in both cases. The mother had early rebleeding and died. The aneurysm was excluded by coiling in the daughter. Despite occurrence of hydrocephalus and delayed cerebral ischemia, she had an excellent functional outcome. A systematic review of the literature identified seven additional cases. None of the cases were in fact familial. All patients had a previous medical history of multiple fractures. Seven aneurysms were resolved, three by surgical clipping and four by endovascular procedure. No periprocedural complication was reported. One patient died prematurely and 6 experienced good functional outcome. We report the first familial cases of aneurysmal subarachnoid hemorrhage in osteogenesis imperfecta patients. Intracranial aneurysms are probably linked to a collagen pathology, which is at the origin of osteogenesis imperfecta. In cases of aneurysmal subarachnoid hemorrhage in an osteogenesis imperfecta family, intracranial aneurysm screenings in the relatives showing osteogenesis imperfecta should be considered. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. The 100 most cited articles in the endovascular management of intracranial aneurysms.

    Science.gov (United States)

    Maingard, Julian; Phan, Kevin; Ren, Yifan; Kok, Hong Kuan; Thijs, Vincent; Hirsch, Joshua A; Lee, Michael J; Chandra, Ronil V; Brooks, Duncan Mark; Asadi, Hamed

    2018-01-19

    Endovascular interventions for intracranial aneurysms have evolved substantially over the past several decades. A citation rank list is used to measure the scientific and/or clinical impact of an article. Our objective was to identify and analyze the characteristics of the 100 most cited articles in the field of endovascular therapy for intracranial aneurysms. We performed a retrospective bibliometric analysis between July and August 2017. Articles were searched on the Science Citation Index Expanded database using Web of Science in order to identify the most cited articles in the endovascular therapy of intracranial aneurysms since 1945. Using selected key terms ('intracranial aneurysm', 'aneurysm', 'aneurysmal subarachnoid', 'endovascular', 'coiling', 'stent-assisted', 'balloon-assisted', 'flow-diversion') yielded a total of 16 314 articles. The top 100 articles were identified and analyzed to extract relevant information, including citation count, authorship, article type, subject matter, institution, country of origin, and year of publication. Citations for the top 100 articles ranged from 133 to 1832. All articles were cited an average of 27 times per year. There were 45 prospective studies, including 7 level-II randomized controlled trials. Most articles were published in the 2000s (n=53), and the majority constituted level III or level IV evidence. Half of the top 100 articles arose from the USA. This study provides a comprehensive overview of the most cited articles in the endovascular management of intracranial aneurysms. It recognizes the contributions made by key authors and institutions, providing an important framework to an enhanced understanding of the evidence behind the endovascular treatment of aneurysms. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Transcatheter coil occluder for closure of ventricular septal defect (a report of 4 cases)

    International Nuclear Information System (INIS)

    Gao Wei; Zhou Aiqing; Yu Zhiqing; Li Fen; Zhong Yumin; Zhang Yuqi; Huang Meirong; Sun Kun

    2005-01-01

    Objective: To explore the indication, methodology and complication of transcatheter coil closure of ventricular septal defect (VSD) in children. Methods: Transcatheter closure of perimembranous VSD with coils was performed in 4 cases from 2003 to 2005. The Duct-Occlude (pfm) and detachable coil (Cook) were chosen for embolization depending on the results of the left ventricular angiogram. The coil size was generally about 1-4 mm larger than the diameter of VSD. Follow up was carried out with echocardiography, ultrasound and clinical examination. Results: The defect diameters of the four cases were 2.0 mm, 2.7 mm, 2.5 mm and 1.5 mm respectively. The Duct-Occlude were successfully implanted in 3 cases of perimembranous VSD with the same type coil (OD[mm]7-3-6, windings 5-3-4) for each. One detachable coil (Cook) (5 x 5) was implanted in the remaining case. All cases had trivial residual shunt immediately after implantation which disappeared 24 hours later. Follow-up for 2 months to one year showed no coil displacement and secondary bacterial arteritis. No tricuspid and aortic regurgitation, no emboli, no endocarditis, and no arrhythmia were found. Conclusions: Coil closure of some small VSD with membranate part pseudo-ventricular aneurysm has good efficacy with the advantages of simple operation, less metal content and mini-invasion also applicable for infants. (authors)

  7. Contribution of whole platelet aggregometry to the endovascular management of unruptured aneurysms: an institutional experience.

    Science.gov (United States)

    Aoun, S G; Welch, B G; Pride, L G; White, J; Novakovic, R; Hoes, K; Sarode, R

    2017-10-01

    Stent-assisted coiling of intracranial aneurysms is an efficient alternative treatment to surgical clipping but requires prolonged antiplatelet therapy. Some patients are non-responsive to aspirin and/or clopidogrel. To analyze the implications of this assessment using the 'whole blood aggregometry (WBA) by impedance' technique. The Southwestern Tertiary Aneurysm Registry was reviewed between 2002 and 2012 for patients with unruptured aneurysms treated with stent-assisted coiling. The study population was divided into patients who were tested preoperatively for platelet responsiveness to aspirin and clopidogrel ('tested' patients) and those who were not ('non-tested'). Where necessary, tested patients received additional doses of antiplatelet drugs to achieve adequate platelet inhibition. Endpoints included the incidence of non-responsiveness, the rates of thrombotic and hemorrhagic complications, and the rates of permanent morbidity and mortality. A total of 266 patients fulfilled our selection criteria: 114 non-tested patients who underwent 121 procedures, and 152 tested patients who underwent 171 procedures. The two groups did not vary significantly in patient age, gender, and aneurysms location. Aspirin non-responsiveness was detected in 3 patients (1.75%) and clopidogrel non-responsiveness in 21 patients (12.3%). Non-tested patients had an 11.6% rate of thrombotic complications with a 4.1% permanent morbidity or mortality rate versus 2.3% and 0.6% in tested patients (p=0.0013). The incidence of hemorrhagic complications was similar between the two groups. Preoperative platelet inhibition testing using WBA can be useful to assess and correct antiaggregant non-responsiveness, and may reduce postoperative mortality and permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography

    International Nuclear Information System (INIS)

    Weber, W.; Henkes, H.; Nahser, H.C.; Roer, N.; Kuehne, D.; Yousry, T.A.; Felber, S.R.

    2001-01-01

    The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased evaluation. The first blinded evaluation revealed a sensitivity of 71% and a specificity of 95% for MRA assessment of aneurysm reperfusion. In the second consensus reading, the sensitivity increased to 92% and the specificity was 98%. The blinded reading indicates that MRA is a useful adjunct to DSA for the assessment of durable results after endovascular treatment of intracranial aneurysms. In the consensus reading it became obvious that sensitivity and specificity of MRA can be increased to 92 and 98%, respectively, if the results were evaluated by experienced neuroradiologists, including prior knowledge of all other examinations. We have already increased the follow-up intervals for DSA and use MRA intermittently, based on these results. (orig.)

  9. Effect of Aneurysmal Subarachnoid Hemorrhage on Word Generation

    Directory of Open Access Journals (Sweden)

    Daniella Ladowski

    2014-01-01

    Full Text Available Background. Aneurysmal subarachnoid hemorrhage (aSAH survivors commonly exhibit impairment on phonemic and semantic fluency tests; however, it is unclear which of the contributing cognitive processes are compromised in aSAH patients. One method of disentangling these processes is to compare initial word production, which is a rapid, semiautomatic, frontal-executive process, and late phase word production, which is dependent on more effortful retrieval and lexical size and requires a more distributed neural network. Methods. Seventy-two individuals with aSAH and twenty-five control subjects were tested on a cognitive battery including the phonemic and semantic fluency task. Demographic and clinical information was also collected. Results. Compared to control subjects, patients with aSAH were treated by clipping and those with multiple aneurysms were impaired across the duration of the phonemic test. Among patients treated by coiling, those with anterior communicating artery aneurysms or a neurological complication (intraventricular hemorrhage, vasospasm, and edema showed worse output only in the last 45 seconds of the phonemic test. Patients performed comparably to control subjects on the semantic test. Conclusions. These results support a “diffuse damage” hypothesis of aSAH, indicated by late phase phonemic fluency impairment. Overall, the phonemic and semantic tests represent a viable, rapid clinical screening tool in the postoperative assessment of patients with aSAH.

  10. First Indian single center experience with pipeline embolization device for complex intracranial aneurysms.

    Science.gov (United States)

    Cherian, Mathew P; Yadav, Manish Kumar; Mehta, Pankaj; Vijayan, K; Arulselvan, V; Jayabalan, Suresh

    2014-01-01

    Flow diversion is a novel method of therapy wherein an endoluminal sleeve, the flow diverter stent is placed across the neck of complex aneurysms to curatively reconstruct abnormal vasculature. We present the first Indian single center experience with the pipeline embolization device (PED) and 6 months follow-up results of 5 patients. Five complex or recurrent intracranial aneurysms in five patients were treated with PED. The patients were followed-up with magnetic resonance angiography (MRA) after 4 weeks and conventional angiography after 6 months. Feasibility, complications, clinical outcome, early 1-month MRA and 6 months conventional angiographic follow-up results were analyzed. Of the five aneurysms treated, four were in the anterior circulation and one in the posterior circulation. All five patients were treated with a single PED in each, and additionally coils were used in one patient. At 1-month MRA follow-up, complete occlusion was seen in 2 (40%) of the five cases. Post 6 months conventional angiography showed complete occlusion of the aneurysm sac in all five cases (100%). Side branch ostia were covered in three patients, all of which were patent (100%). There was no incidence of major neurological morbidity or mortality. One patient (20%) who had basilar top aneurysm experienced minor neurological disability after 5 days which partially improved. Pipeline embolization device for complex and recurrent aneurysms is technically feasible, safe, offers low complication rate, and definitive vascular reconstruction. PED can be used without fear of occlusion of covered eloquent side branches and perforators.

  11. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  12. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  13. Hemodynamic effect of bypass geometry on intracranial aneurysm: A numerical investigation.

    Science.gov (United States)

    Kurşun, Burak; Uğur, Levent; Keskin, Gökhan

    2018-05-01

    Hemodynamic analyzes are used in the clinical investigation and treatment of cardiovascular diseases. In the present study, the effect of bypass geometry on intracranial aneurysm hemodynamics was investigated numerically. Pressure, wall shear stress (WSS) and velocity distribution causing the aneurysm to grow and rupture were investigated and the best conditions were tried to be determined in case of bypassing between basilar (BA) and left/right posterior arteries (LPCA/RPCA) for different values of parameters. The finite volume method was used for numerical solutions and calculations were performed with the ANSYS-Fluent software. The SIMPLE algorithm was used to solve the discretized conservation equations. Second Order Upwind method was preferred for finding intermediate point values in the computational domain. As the blood flow velocity changes with time, the blood viscosity value also changes. For this reason, the Carreu model was used in determining the viscosity depending on the velocity. Numerical study results showed that when bypassed, pressure and wall shear stresses reduced in the range of 40-70% in the aneurysm. Numerical results obtained are presented in graphs including the variation of pressure, wall shear stress and velocity streamlines in the aneurysm. Considering the numerical results for all parameter values, it is seen that the most important factors affecting the pressure and WSS values in bypassing are the bypass position on the basilar artery (L b ) and the diameter of the bypass vessel (d). Pressure and wall shear stress reduced in the range of 40-70% in the aneurysm in the case of bypass for all parameters. This demonstrates that pressure and WSS values can be greatly reduced in aneurysm treatment by bypassing in cases where clipping or coil embolization methods can not be applied. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Pituitary Dysfunction from an Unruptured Ophthalmic Internal Carotid Artery Aneurysm with Improved 2-year Follow-up Results: A Case Report.

    Science.gov (United States)

    Qi, Meng; Ye, Ming; Li, Meng; Zhang, Peng

    2018-01-01

    Internal carotid artery (ICA) supraclinoid segment aneurysms extending into the sellar region and leading to pituitary dysfunction are a rare occurrence. To date, long-term follow up of pituitary function 2 years post-treatment has never been reported. Herein, we present a case of pituitary dysfunction due to an unruptured ophthalmic segment internal carotid artery aneurysm and report improved 2-year follow-up results. A 76-year-old male presented with disturbed consciousness due to hyponatremia, which was caused by hypoadrenocorticism resulting from pituitary dysfunction complicated by hypogonadism and hypothyroidism. Computed tomography angiography revealed an intracranial aneurysm of the ophthalmic segment of the right ICA with an intrasellar extension. Thus, digital subtraction angiography and coil embolization were performed, followed by hormone replacement therapy. A 2-year follow-up revealed a partial improvement in the pituitary function, including complete restoration of thyroid-stimulating hormone level and other thyroid hormones levels, and partial restoration of testosterone levels, followed by discontinuation of thyroid hormone replacement therapy. However, the mechanisms of such pituitary dysfunction and the effects of various treatments, including clipping and coiling, on different hormones of pituitary function recovery remain unclear. A long-term follow-up of >2 years may elucidate the pituitary function recovery post-treatment and provide a medication adjustment for hormone replacement therapy.

  15. Internal carotid artery aneurysms, cranial nerve dysfunction and headache: the role of deformation and pulsation

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Catarino, M.; Wikholm, G.; Svendsen, P. [Interventional Neuroradiology, Sahlgrenska Hospital, Goeteborg (Sweden); Frisen, L. [Ophthalmology Dept., Sahlgrenska Hospital, Goeteborg (Sweden); Elfverson, J. [Neurosurgery Dept., Sahlgrenska Hospital, Goeteborg (Sweden); Quiding, L. [Medical Physics and Biomedical Engineering Dept., Sahlgrenska Hospital, Goeteborg (Sweden)

    2003-04-01

    Cranial nerve dysfunction and headache may occur with unruptured aneurysms of the cavernous and supraclinoid portions of the internal carotid artery. Nerve deformation (mass effect) and transmitted pulsations have been suggested as pathogenetic mechanisms. Differentiation may be possible by studying effects of endovascular treatment with Guglielmi detachable coils. Symptoms and signs of cranial neuropathy were retrospectively contrasted with angiographic aneurysm volumes before and after treatment in 10 patients. Mean follow-up was 36 months. Symptoms improved in three of four patients with cranial nerve dysfunction and in all patients with headache: None of the other patients, one with cranial nerve dysfunction, and three who were asymptomatic, developed any new symptoms after treatment. Aneurysm volume ranged from 0.1 to 2.7 cm{sup 3} before and 0.2 to 5.7 cm{sup 3} after treatment; the size thus increased by 15 to 110%, a change which was statistically significant (P = 0.004). The consistent increase in aneurysm volume with treatment is not associated with clinical deterioration, suggesting that deformation and displacement play a minor role in cranial neuropathy and that transmitted pulsations may be more important. (orig.)

  16. Internal carotid artery aneurysms, cranial nerve dysfunction and headache: the role of deformation and pulsation

    International Nuclear Information System (INIS)

    Rodriguez-Catarino, M.; Wikholm, G.; Svendsen, P.; Frisen, L.; Elfverson, J.; Quiding, L.

    2003-01-01

    Cranial nerve dysfunction and headache may occur with unruptured aneurysms of the cavernous and supraclinoid portions of the internal carotid artery. Nerve deformation (mass effect) and transmitted pulsations have been suggested as pathogenetic mechanisms. Differentiation may be possible by studying effects of endovascular treatment with Guglielmi detachable coils. Symptoms and signs of cranial neuropathy were retrospectively contrasted with angiographic aneurysm volumes before and after treatment in 10 patients. Mean follow-up was 36 months. Symptoms improved in three of four patients with cranial nerve dysfunction and in all patients with headache: None of the other patients, one with cranial nerve dysfunction, and three who were asymptomatic, developed any new symptoms after treatment. Aneurysm volume ranged from 0.1 to 2.7 cm 3 before and 0.2 to 5.7 cm 3 after treatment; the size thus increased by 15 to 110%, a change which was statistically significant (P = 0.004). The consistent increase in aneurysm volume with treatment is not associated with clinical deterioration, suggesting that deformation and displacement play a minor role in cranial neuropathy and that transmitted pulsations may be more important. (orig.)

  17. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  18. In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI

    International Nuclear Information System (INIS)

    Isoda, Haruo; Takeda, Hiroyasu; Yamashita, Shuhei; Takehara, Yasuo; Sakahara, Harumi; Ohkura, Yasuhide; Kosugi, Takashi; Hirano, Masaya; Hiramatsu, Hisaya; Namba, Hiroki; Alley, Marcus T.; Bammer, Roland; Pelc, Norbert J.

    2010-01-01

    Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The purpose of our study was to perform in vivo hemodynamic analysis of unruptured intracranial aneurysms of magnetic resonance fluid dynamics using time-resolved three-dimensional phase-contrast MRI (4D-Flow) at 1.5 T and to analyze relationships between hemodynamics and wall shear stress (WSS) and oscillatory shear index (OSI). This study included nine subjects with 14 unruptured aneurysms. 4D-Flow was performed by a 1.5-T magnetic resonance scanner with a head coil. We calculated in vivo streamlines, WSS, and OSI of intracranial aneurysms based on 4D-Flow with our software. We evaluated the number of spiral flows in the aneurysms and compared the differences in WSS or OSI between the vessel and aneurysm and between whole aneurysm and the apex of the spiral flow. 3D streamlines, WSS, and OSI distribution maps in arbitrary direction during the cardiac phase were obtained for all intracranial aneurysms. Twelve aneurysms had one spiral flow each, and two aneurysms had two spiral flows each. The WSS was lower and the OSI was higher in the aneurysm compared to the vessel. The apex of the spiral flow had a lower WSS and higher OSI relative to the whole aneurysm. Each intracranial aneurysm in this study had at least one spiral flow. The WSS was lower and OSI was higher at the apex of the spiral flow than the whole aneurysmal wall. (orig.)

  19. In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI.

    Science.gov (United States)

    Isoda, Haruo; Ohkura, Yasuhide; Kosugi, Takashi; Hirano, Masaya; Takeda, Hiroyasu; Hiramatsu, Hisaya; Yamashita, Shuhei; Takehara, Yasuo; Alley, Marcus T; Bammer, Roland; Pelc, Norbert J; Namba, Hiroki; Sakahara, Harumi

    2010-10-01

    Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The purpose of our study was to perform in vivo hemodynamic analysis of unruptured intracranial aneurysms of magnetic resonance fluid dynamics using time-resolved three-dimensional phase-contrast MRI (4D-Flow) at 1.5 T and to analyze relationships between hemodynamics and wall shear stress (WSS) and oscillatory shear index (OSI). This study included nine subjects with 14 unruptured aneurysms. 4D-Flow was performed by a 1.5-T magnetic resonance scanner with a head coil. We calculated in vivo streamlines, WSS, and OSI of intracranial aneurysms based on 4D-Flow with our software. We evaluated the number of spiral flows in the aneurysms and compared the differences in WSS or OSI between the vessel and aneurysm and between whole aneurysm and the apex of the spiral flow. 3D streamlines, WSS, and OSI distribution maps in arbitrary direction during the cardiac phase were obtained for all intracranial aneurysms. Twelve aneurysms had one spiral flow each, and two aneurysms had two spiral flows each. The WSS was lower and the OSI was higher in the aneurysm compared to the vessel. The apex of the spiral flow had a lower WSS and higher OSI relative to the whole aneurysm. Each intracranial aneurysm in this study had at least one spiral flow. The WSS was lower and OSI was higher at the apex of the spiral flow than the whole aneurysmal wall.

  20. Endovascular treatment of type II endoleak following thoracic endovascular aortic repair for thoracic aortic aneurysm: Case report of squeeze technique to reach the aneurysmal sac

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Jung; Kim, Chang Won; Lee, Tae Hong; Song, Seung Hwan; Lee, Chung Won; Chung, Sung Woon [Pusan National University Hospital, School of Medicine, Pusan National University, Busan (Korea, Republic of)

    2014-12-15

    Type II endoleaks are common after thoracic endovascular aortic repair (TEVAR). Various strategies are introduced to manage type II endoleaks, such as the use of coils, plugs, or liquid embolic agents (histoacryl, thrombin, onyx, etc.) through a transarterial approach or a direct puncture of the aneurysmal sac. We herein report a case of a type II endoleak caused by reverse blood flow through intercostal artery after TEVAR which was successfully treated with n-butyl cyanoacrylate (histoacryl)-lipiodol mixture by a squeeze technique to reach the aneurismal sac using a microcatheter.

  1. Non-enhanced MR imaging of cerebral aneurysms: 7 Tesla versus 1.5 Tesla.

    Science.gov (United States)

    Wrede, Karsten H; Dammann, Philipp; Mönninghoff, Christoph; Johst, Sören; Maderwald, Stefan; Sandalcioglu, I Erol; Müller, Oliver; Özkan, Neriman; Ladd, Mark E; Forsting, Michael; Schlamann, Marc U; Sure, Ulrich; Umutlu, Lale

    2014-01-01

    To prospectively evaluate 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) in comparison to 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of unruptured intracranial aneurysms (UIA). Sixteen neurosurgical patients (male n = 5, female n = 11) with single or multiple UIA were enrolled in this trial. All patients were accordingly examined at 7 Tesla and 1.5 Tesla MRI utilizing dedicated head coils. The following sequences were obtained: 7 Tesla TOF MRA, 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced MPRAGE. Image analysis was performed by two radiologists with regard to delineation of aneurysm features (dome, neck, parent vessel), presence of artifacts, vessel-tissue-contrast and overall image quality. Interobserver accordance and intermethod comparisons were calculated by kappa coefficient and Lin's concordance correlation coefficient. A total of 20 intracranial aneurysms were detected in 16 patients, with two patients showing multiple aneurysms (n = 2, n = 4). Out of 20 intracranial aneurysms, 14 aneurysms were located in the anterior circulation and 6 aneurysms in the posterior circulation. 7 Tesla MPRAGE imaging was superior over 1.5 and 7 Tesla TOF MRA in the assessment of all considered aneurysm and image quality features (e.g. image quality: mean MPRAGE7T: 5.0; mean TOF7T: 4.3; mean TOF1.5T: 4.3). Ratings for 7 Tesla TOF MRA were equal or higher over 1.5 Tesla TOF MRA for all assessed features except for artifact delineation (mean TOF7T: 4.3; mean TOF1.5T 4.4). Interobserver accordance was good to excellent for most ratings. 7 Tesla MPRAGE imaging demonstrated its superiority in the detection and assessment of UIA as well as overall imaging features, offering excellent interobserver accordance and highest scores for all ratings. Hence, it may bear the potential to serve as a high-quality diagnostic tool for pretherapeutic assessment and

  2. The intracranial aneurysm: cost-effective of the aneurysm intra-artery GDC embolization and the aneurysm incarcerated operation

    International Nuclear Information System (INIS)

    Pan Jie; Zhang Shizheng

    2008-01-01

    Objective: To evaluate the cost-effectiveness of the aneurysm intra-artery GDC embolization and the aneurysm clapping of intracranial aneurysm, and to give the instruction for the clinical practice. Methods: A case control study (1 vs. 1) was developed to evaluate the cost in hospital, the cost for return visit and the Quality-adusted Life-Year (QALY) and lifetime costs of the intra-artery GDC embolization and the aneurysm clapping of intraeranial aneurysm, under the matching of the age, sex, living place, the size and place of the aneurysm, and the Hunt and Hess score. Clinically effectiveness dates were derived from the medical records. Cost dates were derived from follow-up by telephones or letters. The correlation analysis was done with the SPSS 13.0. Results: The cost in hospital in AC group was (54 945±16 946)RMBs, which was higher than the ones in AE group (63 768±12 665) RMBs, (t=1.71, P 0.05). Conclusion: The results suggest that the two therapies have no difference in cost effective rate. Considering the physical and mental loss, the aneurysm intra-arteu GDC embolization was better than the aneurysm clapping for the patients with aneurysm that diameter less than 25 mm. (authors)

  3. Brain Aneurysm

    Science.gov (United States)

    A brain aneurysm is an abnormal bulge or "ballooning" in the wall of an artery in the brain. They are sometimes called berry aneurysms because they ... often the size of a small berry. Most brain aneurysms produce no symptoms until they become large, ...

  4. Preliminary study of in vivo hemodynamic analysis of intracranial aneurysms using time-resolved three-dimensional phase-contrast MRI and in-house software [Presidential award proceedings

    International Nuclear Information System (INIS)

    Isoda, Haruo; Ohkura, Yasuhide; Seo, Taro

    2007-01-01

    We calculated in vivo wall shear stress (WSS) and streamlines of intracranial aneurysms and analyzed the relationships between the hemodynamics and WSS of the aneurysms using time-resolved three-dimensional (3D) phase-contrast magnetic resonance (MR) imaging (4D-Flow) and in-house software. We studied 10 subjects with 11 aneurysms. 4D-flow was performed using a 1.5T GE MR scanner with head coil. 3D time-of-flight (TOF) MR angiography was performed for geometric information. The software calculated the WSS based on interpolated shearing velocity using the data set obtained by 4D-flow near the wall and provided us with 3D streamlines. We acquired 3D streamlines and WSS distribution maps in arbitrary directions during the cardiac phase for all intracranial aneurysms, and each intracranial aneurysm in this study had at least one spiral flow. We noted lower WSS with lower flow velocities at the apex of the spiral flow. (author)

  5. Pituitary dysfunction from an unruptured ophthalmic internal carotid artery aneurysm with improved 2-year follow-up results: A case report

    Directory of Open Access Journals (Sweden)

    Qi Meng

    2018-04-01

    Full Text Available Internal carotid artery (ICA supraclinoid segment aneurysms extending into the sellar region and leading to pituitary dysfunction are a rare occurrence. To date, long-term follow up of pituitary function 2 years post-treatment has never been reported. Herein, we present a case of pituitary dysfunction due to an unruptured ophthalmic segment internal carotid artery aneurysm and report improved 2-year follow-up results. A 76-year-old male presented with disturbed consciousness due to hyponatremia, which was caused by hypoadrenocorticism resulting from pituitary dysfunction complicated by hypogonadism and hypothyroidism. Computed tomography angiography revealed an intracranial aneurysm of the ophthalmic segment of the right ICA with an intrasellar extension. Thus, digital subtraction angiography and coil embolization were performed, followed by hormone replacement therapy. A 2-year follow-up revealed a partial improvement in the pituitary function, including complete restoration of thyroid-stimulating hormone level and other thyroid hormones levels, and partial restoration of testosterone levels, followed by discontinuation of thyroid hormone replacement therapy. However, the mechanisms of such pituitary dysfunction and the effects of various treatments, including clipping and coiling, on different hormones of pituitary function recovery remain unclear. A long-term follow-up of >2 years may elucidate the pituitary function recovery post-treatment and provide a medication adjustment for hormone replacement therapy.

  6. Quantitative Susceptibility Mapping as a Possible Tool to Radiographically Diagnose Sentinel Headache Associated with Intracranial Aneurysm: Case Report.

    Science.gov (United States)

    Nakagawa, Daichi; Cushing, Cameron; Nagahama, Yasunori; Allan, Lauren; Hasan, David

    2017-07-01

    Sentinel headache (SH) occurs before aneurysm rupture in an estimated 15%-60% of cases of aneurysmal subarachnoid hemorrhage (aSAH). By definition, noncontrast computed tomography (CT) scan of the brain and lumbar puncture are both negative in patients presenting with SH. One of the theories explaining this phenomenon is that microhemorrhage (MH) from the aneurysm wall contribute to iron deposition in the interface between the aneurysm wall and brain parenchyma. Quantitative susceptibility mapping (QSM) is a recently introduced magnetic resonance imaging (MRI) technique that has proven capable of localizing the deposition of paramagnetic metals, particularly ferric iron. Thus, the QSM sequence may be able to detect iron deposition secondary to MH. A 76-year-old male presented with the "worst headache of my life." Noncontrast head CT scan and lumbar puncture were negative. Magnetic resonance angiography (MRA) of the brain revealed an anterior communicating artery (A-com) aneurysm measuring 7 mm with a large bleb. T1-weighted imaging (WI), T2-WI, MRA, T2 star-weighted angiography (SWAN), and QSM sequences were obtained. T2-WI, SWAN, and QSM revealed isointense, hypointense, and hyperintense signals, respectively, at the interface of the aneurysm wall and brain tissue. These findings were consistent with deposition of ferric iron at this interface. The A-com aneurysm was treated with coil embolization, and the patient exhibited no postoperative deficits. The MRI QSM sequence can localize iron deposition resulting from MH within an aneurysmal wall. This sequence may be a promising imaging tool for screening patients presenting with SH. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  8. Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique.

    Science.gov (United States)

    Nevzati, Edin; Rey, Jeannine; Coluccia, Daniel; D'Alonzo, Donato; Grüter, Basil; Remonda, Luca; Fandino, Javier; Marbacher, Serge

    2017-10-01

    The steady progess in the armamentarium of techniques available for endovascular treatment of intracranial aneurysms requires affordable and reproducable experimental animal models to test novel embolization materials such as stents and flow diverters. The aim of the present project was to design a safe, fast, and standardized surgical technique for stent assisted embolization of saccular aneurysms in a rat animal model. Saccular aneurysms were created from an arterial graft from the descending aorta.The aneurysms were microsurgically transplanted through end-to-side anastomosis to the infrarenal abdominal aorta of a syngenic male Wistar rat weighing >500 g. Following aneurysm anastomosis, aneurysm embolization was performed using balloon expandable magnesium stents (2.5 mm x 6 mm). The stent system was retrograde introduced from the lower abdominal aorta using a modified Seldinger technique. Following a pilot series of 6 animals, a total of 67 rats were operated according to established standard operating procedures. Mean surgery time, mean anastomosis time, and mean suturing time of the artery puncture site were 167 ± 22 min, 26 ± 6 min and 11 ± 5 min, respectively. The mortality rate was 6% (n=4). The morbidity rate was 7.5% (n=5), and in-stent thrombosis was found in 4 cases (n=2 early, n=2 late in stent thrombosis). The results demonstrate the feasibility of standardized stent occlusion of saccular sidewall aneurysms in rats - with low rates of morbidity and mortality. This stent embolization procedure combines the opportunity to study novel concepts of stent or flow diverter based devices as well as the molecular aspects of healing.

  9. Magnetic Resonance angiography with bolus contrast agent in abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Di Cesare, E.; Cerone, G.; Giordano, A.V.; Marsili, L.; Barile, A.; Michelini, O.; Masciocchi, C.; Spartera, C.

    2000-01-01

    Purpose of this paper is to investigate the potentials of 3D breath-hold contrast-enhanced Magnetic Resonance Angiography (MRA) in the diagnosis, follow-up and treatment planning of abdominal aortic aneurysms. Twenty-four patients with infrarenal aortic aneurysm underwent MRA. It was used a 1.5 T unit (GE Horizon, Echospeed 8.2), a phased array surface coil and 3D Fast SPGR T1-weighted sequences acquired on the coronal plane during patient breath-hold and after contrast agent i.v. administration. A bolus-test was done before angiography to optimize imaging delay time. After 3D MRA a Fast-SPGR T1-weighted sequence was acquired on the axial plane. The 3D MRA source images were processed with the MIP algorithm. Qualitative and quantitative analyses were carried out. Helical CT was performed in 6 cases and DSA in 7 cases. Surgery was the reference standard in 15 patients. MRA depicted aneurysm thrombosis in 22 cases, carrefour involvement in 18 cases and iliac arteries involvement in 3 cases. Accessory renal arteries were shown in 4 cases; iliac artery stenosis was associated in 5 cases. There was agreement between MR and Helical CT and DSA findings: surgery confirmed MRA results in 15/15 cases. 3D contrast-enhanced MRA can be considered the method of choice in the follow-up and treatment planning of abdominal aortic aneurysms, because it provides both angiographic and tomographic images: this allows to obtain more information, noninvasively and without the use of ionizing radiations [it

  10. Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young; Lee, Do Yun; Lee, Kwang Hun [Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Won, Jong Yun [Gangnam Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Choi, Dong Hoon; Shim, Won Heum [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months). Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications. The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.

  11. Visceral artery aneurysms: Incidence, management, and outcome analysis in a tertiary care center over one decade

    Energy Technology Data Exchange (ETDEWEB)

    Pitton, Michael B.; Dappa, Evelyn; Jungmann, Florian; Kloeckner, Roman; Schotten, Sebastian; Wirth, Gesine M.; Mildenberger, Peter; Kreitner, Karl-Friedrich; Oberholzer, Katja; Dueber, Christoph [University Hospital of Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Mittler, Jens; Lang, Hauke [University Hospital of Mainz, Department of Abdominal, Visceral and Transplantation Surgery, Mainz (Germany)

    2015-07-15

    To evaluate the incidence, management, and outcome of visceral artery aneurysms (VAA) over one decade. 233 patients with 253 VAA were analyzed according to location, diameter, aneurysm type, aetiology, rupture, management, and outcome. VAA were localized at the splenic artery, coeliac trunk, renal artery, hepatic artery, superior mesenteric artery, and other locations. The aetiology was degenerative, iatrogenic after medical procedures, connective tissue disease, and others. The rate of rupture was much higher in pseudoaneurysms than true aneurysms (76.3 % vs.3.1 %). Fifty-nine VAA were treated by intervention (n = 45) or surgery (n = 14). Interventions included embolization with coils or glue, covered stents, or combinations of these. Thirty-five cases with ruptured VAA were treated on an emergency basis. There was no difference in size between ruptured and non-ruptured VAA. After interventional treatment, the 30-day mortality was 6.7 % in ruptured VAA compared to no mortality in non-ruptured cases. Follow-up included CT and/or MRI after a mean period of 18.0 ± 26.8 months. The current status of the patient was obtained by a structured telephone survey. Pseudoaneurysms of visceral arteries have a high risk for rupture. Aneurysm size seems to be no reliable predictor for rupture. Interventional treatment is safe and effective for management of VAA. (orig.)

  12. Interest of Flow Diversion Prostheses in the Management of Unruptured Intracranial Aneurysms

    Directory of Open Access Journals (Sweden)

    Xavier Armoiry

    2012-01-01

    Full Text Available Flow diversion prostheses represent a new endovascular approach aimed at treating patients with large wide-neck aneurysms. Our objective is to present this new technology, to review the clinical studies on efficacy, and to emphasize its current limits. Flow diversion prostheses consist of a cylinder made of a large number of braided microfilaments providing a large metallic surface when deployed and inducing a blood flow diversion outside the aneurysm. Two different brands are currently available. Clinical data supporting their efficacy are currently limited to six non comparative cohort studies that included between 18 and 107 patients. Procedural implantation was shown to be feasible in more than 90% and safe with a thirty-day mortality between 2.8 and 5.5%. Complete occlusion rates at twelve months varied between 85.7 and 100%. Even though promising, the current status of flow diversion prostheses needs further evaluation with randomized, prospective, clinical trials with comparison to conventional strategies including endovascular coiling or surgical clipping.

  13. Ultra Low Density Shape Memory Polymer Foams With Tunable Physicochemical Properties for Treatment of intracranial Aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, Pooja [Texas A & M Univ., College Station, TX (United States)

    2013-12-01

    Shape memory polymers (SMPs) are a rapidly emerging class of smart materials that can be stored in a deformed temporary shape, and can actively return to their original shape upon application of an external stimulus such as heat, pH or light. This behavior is particularly advantageous for minimally invasive biomedical applications comprising embolic/regenerative scaffolds, as it enables a transcatheter delivery of the device to the target site. The focus of this work was to exploit this shape memory behavior of polyurethanes, and develop an efficient embolic SMP foam device for the treatment of intracranial aneurysms.In summary, this work reports a novel family of ultra low density polymer foams which can be delivered via a minimally invasive surgery to the aneurysm site, actuated in a controlled manner to efficiently embolize the aneurysm while promoting physiological fluid/blood flow through the reticulated/open porous structure, and eventually biodegrade leading to complete healing of the vasculature.

  14. Bilateral Intracavernous Carotid Artery Aneurysms Presenting as Diplopia in a Young Patient

    Directory of Open Access Journals (Sweden)

    Nikolaos Kopsachilis

    2013-01-01

    Full Text Available Introduction. Bilateral intracavernous carotid artery aneurysms (ICAAs are extremely rare and difficult to treat. Case Report. A 26-year-old female presented in our clinic with acute diplopia due to oculomotor nerve palsy on the left side. Magnetic resonance imaging of the brain showed two heterogeneously enhanced masses indicating bilateral ICAA. An endovascular coil embolization was performed on the left side successfully, resulting in resolution of her symptoms. Conclusion. Thorough systemic evaluation in young patients with diplopia can reveal life-threatening underlying pathology and prevent major complications.

  15. Treatment of giant and large fusiform middle cerebral artery aneurysms with excision and interposition radial artery graft in a 4-year-old child: case report.

    Science.gov (United States)

    Mrak, Goran; Paladino, Josip; Stambolija, Vasilije; Nemir, Jakob; Sekhar, Laligam N

    2014-03-01

    We report an unusual case of complex giant and large fusiform aneurysms not amenable for clipping or coiling in a 4-year-old child managed with aneurysm resection and radial artery interposition graft. A 4-year-old child presented with repeated severe headache and vomiting. Computed tomography, magnetic resonance imaging, and magnetic resonance angiography and digital subtraction angiography showed a giant fusiform aneurysm on the right middle cerebral artery (MCA). Because of the complex shape, endovascular treatment or clip reconstruction was not possible, and a bypass procedure was planned. Right frontotemporal craniotomy and orbitotomy was performed. Two aneurysms involving the M1 segment of the MCA were found in line, 1 giant, and the other large in size. The aneurysms were resected and treated with short radial artery interposition graft, which was narrower than the proximal or distal MCA. The child recovered normally, and the bypass was patent after 1 year. Large fusiform MCA aneurysms may be difficult to treat, but there are treatment options that include a bypass procedure. Resection and short interposition radial artery graft is an excellent but rare treatment option in a very young child. This was a very successful treatment in this child.

  16. Endovascular treatment of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Dizonno, Massimiliano; Fugazzola, Carlo; Castelli, Patrizio

    2005-01-01

    Purpose. To assess the feasibility and effectiveness of endovascular treatment of splenic artery aneurysm (SAAs). Materials and methods. Between May 2000 and June 2003 we treated 11 true SAAs in 9 patients (7 females and 2 males; mean age 58 years), 8 saccular and 3 fusiform, 4 located at the middle tract of the splenic artery, 5 at the distal tract and 2 intra-parenchymal. The diagnosis was performed with colour-Doppler ultrasound and/or CT-angiography; 7 patients were symptomless, 1 had left hypochondriac pain, and 1 had acute abdomen caused by a ruptured SAA. Four SAAs were treated by micro coil embolisation of the aneurysmal sac with preservation of splenic artery patency; in 2 cases this was associated with transcatheter injection of N-butyl-2-cyanoacrylate. Four cases were treated by endovascular ligature, with sectoral spleen ischaemia. One ruptured SAA received emergency treatment with splenic artery cyanoacrylate embolisation. Two intra-parenchymal SAAs were excluded, one by cyanoacrylate embolisation of the afferent artery and the other by transcatheter thrombin injection in the aneurysmal sac. Results. Technical success was observed in all cases (in 10/11 at the end of the procedure; in 1/11 at CT performed 3 days after the procedure). The follow-up (mean 18 months; range 6-36) was performed by colour-Doppler ultrasound and/or CT-angiography 3, 6 and 12 months after the procedure and subsequently once a year; the complete exclusion of the aneurysms was confirmed in 11/11 cases. The complications were: 4 cases of mild pleuritis; fever and left hypochondriac pain 1 day after the procedure (in the same 4 patients and in one other case); 5 cases of sectorial spleen ischaemia and 1 case of diffuse spleen infarction with partial revascularization by collateral vessels. No alteration of the levels of pancreatic enzymes was found; a transitory increase in platelet count occurred only in the patient with diffuse spleen infarction. Conclusions. Using different

  17. Computed tomography angiography spot sign predicts intraprocedural aneurysm rupture in subarachnoid hemorrhage.

    Science.gov (United States)

    Burkhardt, Jan-Karl; Neidert, Marian Christoph; Stienen, Martin Nikolaus; Schöni, Daniel; Fung, Christian; Roethlisberger, Michel; Corniola, Marco Vincenzo; Bervini, David; Maduri, Rodolfo; Valsecchi, Daniele; Tok, Sina; Schatlo, Bawarjan; Bijlenga, Philippe; Schaller, Karl; Bozinov, Oliver; Regli, Luca

    2017-07-01

    To analyze whether the computed tomography angiography (CTA) spot sign predicts the intraprocedural rupture rate and outcome in patients with aneurysmal subarachnoid hemorrhage (aSAH). From a prospective nationwide multicenter registry database, 1023 patients with aneurysmal subarachnoid hemorrhage (aSAH) were analyzed retrospectively. Descriptive statistics and logistic regression analysis were used to compare spot sign-positive and -negative patients with aneurysmal intracerebral hemorrhage (aICH) for baseline characteristics, aneurysmal and ICH imaging characteristics, treatment and admission status as well as outcome at discharge and 1-year follow-up (1YFU) using the modified Rankin Scale (mRS). A total of 218 out of 1023 aSAH patients (21%) presented with aICH including 23/218 (11%) patients with spot sign. Baseline characteristics were comparable between spot sign-positive and -negative patients. There was a higher clip-to-coil ratio in patients with than without aICH (both spot sign positive and negative). Median aICH volume was significantly higher in the spot sign-positive group (50 ml, 13-223 ml) than in the spot sign-negative group (18 ml, 1-416; p spot sign-positive aICH thus were three times as likely as those with spot sign-negative aICH to show an intraoperative aneurysm rupture [odds ratio (OR) 3.04, 95% confidence interval (CI) 1.04-8.92, p = 0.046]. Spot sign-positive aICH patients showed a significantly worse mRS at discharge (p = 0.039) than patients with spot sign-negative aICH (median mRS 5 vs. 4). Logistic regression analysis showed that the spot sign was an aICH volume-dependent predictor for outcome. Both spot sign-positive and -negative aICH patients showed comparable rates of hospital death, death at 1YFU and mRS at 1YFU. In this multicenter data analysis, patients with spot sign-positive aICH showed higher aICH volumes and a higher rate of intraprocedural aneurysm rupture, but comparable long-term outcome to spot sign

  18. Microsurgical treatment of carotid-ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms

    Science.gov (United States)

    Wang, Jiantao; Kan, Zhisheng; Wang, Shuo

    2017-01-01

    Abstract Background: The clipping of multiple intracranial aneurysms in 1 stage is uncommon. In this case, we report clipping of an ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms via the Dolenc approach. Methods: The main symptoms of the patient are headache, along with nausea and vomiting. The patient's arteriogram revealed a wide-necked aneurysm of the right ophthalmic artery, an irregular aneurysm of the anterior communicating artery, and a basilar artery aneurysm. The surgical intervention for these aneurysms is a challenge because of the complex anatomical relationship with the surrounding structures. The 3 aneurysms, which were not amenable to a single intervention, were successfully clipped in 1 incision. Results: After surgery, the patient reported feeling well. One year after surgery, the patient had no SAH recurrence. Conclusions: Occasionally, surgical treatment was used even for aneurysms of the carotid-ophthalmic artery with aneurysms of anterior communicating artery and basilar artery, which are contraindicated for interventional therapy. PMID:28422878

  19. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    Energy Technology Data Exchange (ETDEWEB)

    Briganti, Francesco, E-mail: frabriga@unina.it [Unit of Interventional Neuroradiology, Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Napoli, Manuela, E-mail: napoli.manuela@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Leone, Giuseppe, E-mail: g.leonemd@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Marseglia, Mariano, E-mail: mariano-marseglia@libero.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Mariniello, Giuseppe, E-mail: giuseppe.mariniello@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Caranci, Ferdinando, E-mail: ferdinando.caranci@unina.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Tortora, Fabio, E-mail: fabiotor@libero.it [Chair of Neuroradiology, “Magrassi Lanzara” Clinical-Surgical Department, Second University of Naples, Viale Colli Aminei 21, 80131 Naples (Italy); Maiuri, Francesco, E-mail: frmaiuri@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy)

    2014-09-15

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  20. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    International Nuclear Information System (INIS)

    Briganti, Francesco; Napoli, Manuela; Leone, Giuseppe; Marseglia, Mariano; Mariniello, Giuseppe; Caranci, Ferdinando; Tortora, Fabio; Maiuri, Francesco

    2014-01-01

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  1. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes T.; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  2. Infected aortic aneurysm and inflammatory aortic aneurysm. In search of an optimal differential diagnosis

    International Nuclear Information System (INIS)

    Ishizaka, Nobukazu; Sohmiya, Koichi; Miyamura, Masatoshi; Umeda, Tatsuya; Tsuji, Motomu; Katsumata, Takahiro; Miyata, Tetsuro

    2012-01-01

    Infected aortic aneurysm and inflammatory aortic aneurysm each account for a minor fraction of the total incidence of aortic aneurysm and are associated with periaortic inflammation. Despite the similarity, infected aortic aneurysm generally shows a more rapid change in clinical condition, leading to a fatal outcome; in addition, delayed diagnosis and misuse of corticosteroid or immunosuppressing drugs may lead to uncontrolled growth of microorganisms. Therefore, it is mandatory that detection of aortic aneurysm is followed by accurate differential diagnosis. In general, infected aortic aneurysm appears usually as a saccular form aneurysm with nodularity, irregular configuration; however, the differential diagnosis may not be easy sometimes for the following reasons: symptoms, such as abdominal and/or back pain and fever, and blood test abnormalities, such as elevated C-reactive protein and enhanced erythrocyte sedimentation rate, are common in infected aortic aneurysm, but they are not found infrequently in inflammatory aortic aneurysm; some inflammatory aortic aneurysms are immunoglobulin (Ig) G4-related, but not all of them; the prevalence of IgG4 positivity in infected aortic aneurysm has not been well investigated; enhanced uptake of 18F-fluorodeoxyglucose (FDG) by 18F-FDG-positron emission tomography may not distinguish between inflammation mediated by autoimmunity and that mediated by microorganism infection. Here we discuss the characteristics of these two forms of aortic aneurysm and the points of which we have to be aware before reaching a final diagnosis. (author)

  3. Molecular basis of coiled-coil oligomerization-state specificity.

    Science.gov (United States)

    Ciani, Barbara; Bjelic, Saša; Honnappa, Srinivas; Jawhari, Hatim; Jaussi, Rolf; Payapilly, Aishwarya; Jowitt, Thomas; Steinmetz, Michel O; Kammerer, Richard A

    2010-11-16

    Coiled coils are extensively and successfully used nowadays to rationally design multistranded structures for applications, including basic research, biotechnology, nanotechnology, materials science, and medicine. The wide range of applications as well as the important functions these structures play in almost all biological processes highlight the need for a detailed understanding of the factors that control coiled-coil folding and oligomerization. Here, we address the important and unresolved question why the presence of particular oligomerization-state determinants within a coiled coil does frequently not correlate with its topology. We found an unexpected, general link between coiled-coil oligomerization-state specificity and trigger sequences, elements that are indispensable for coiled-coil formation. By using the archetype coiled-coil domain of the yeast transcriptional activator GCN4 as a model system, we show that well-established trimer-specific oligomerization-state determinants switch the peptide's topology from a dimer to a trimer only when inserted into the trigger sequence. We successfully confirmed our results in two other, unrelated coiled-coil dimers, ATF1 and cortexillin-1. We furthermore show that multiple topology determinants can coexist in the same trigger sequence, revealing a delicate balance of the resulting oligomerization state by position-dependent forces. Our experimental results should significantly improve the prediction of the oligomerization state of coiled coils. They therefore should have major implications for the rational design of coiled coils and consequently many applications using these popular oligomerization domains.

  4. Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment.

    Science.gov (United States)

    Enomoto, Yukiko; Yamauchi, Keita; Asano, Takahiko; Otani, Katharina; Iwama, Toru

    2018-01-01

    Background and purpose C-arm cone-beam computed tomography (CBCT) has the drawback that image quality is degraded by artifacts caused by implanted metal objects. We evaluated whether metal artifact reduction (MAR) prototype software can improve the subjective image quality of CBCT images of patients with intracranial aneurysms treated with coils or clips. Materials and methods Forty-four patients with intracranial aneurysms implanted with coils (40 patients) or clips (four patients) underwent one CBCT scan from which uncorrected and MAR-corrected CBCT image datasets were reconstructed. Three blinded readers evaluated the image quality of the image sets using a four-point scale (1: Excellent, 2: Good, 3: Poor, 4: Bad). The median scores of the three readers of uncorrected and MAR-corrected images were compared with the paired Wilcoxon signed-rank and inter-reader agreement of change scores was assessed by weighted kappa statistics. The readers also recorded new clinical findings, such as intracranial hemorrhage, air, or surrounding anatomical structures on MAR-corrected images. Results The image quality of MAR-corrected CBCT images was significantly improved compared with the uncorrected CBCT image ( p software improved image quality of CBCT images degraded by metal artifacts.

  5. Factors responsible for poor outcome after intraprocedural rerupture of ruptured intracranial aneurysms: Identification of risk factors, prevention and management on 18 cases

    International Nuclear Information System (INIS)

    Zhang Xin; Long Xiaoao; Luo Bin; Karuna, Tamrakar; Duan Chuanzhi

    2012-01-01

    Purpose: The paper mainly involved the retrospective approach to risk factors of intraprocedual rerupture (IPR) and illustration of our empirical prevention and management on this event as well as its postembolization outcomes evaluation. Materials and methods: Endovascular treatment was performed in 1308 patients with 1308 ruptured intracranial aneurysms, and IPR occurred in 18 cases. We retrospectively reviewed their clinical records and images, and analysis risk factors of IPR by using multivariate logistic regression. Results: The morbidity of IPR was 1.38% and mortality was 33.33%. Nine patients survived from rapid completion of coiling with immediate reversal of heparin anticoagulation with protamine sulfate, and 3 from emergent external ventricular drainage (EVD). However, 9 of them presented with different degrees of disability and 3 were fully recovered. Small aneurysms (diameter ≤ 3.0 mm) (OR 284.212, 95% C.I. 17.368–4650.780, P = 0.000), atherosclerosis (OR 7.866, 95% C.I. 1.113–55.570, P = 0.039), Fisher Grade III (OR 82.099, 95% C.I. 1.563–431.696, P = 0.029), vasospasm (grade I) (OR 32.269, 95% C.I. 2.393–435.132, P = 0.009) and vasospasm (grade II) (OR 30.238, 95% C.I. 1.770–516.552, P = 0.019) are risk factors of IPR. Aneurysms at proximal part of internal carotid artery (ICA), bifurcation and basilar artery (BA) stem (OR 0.003, 95% C.I. 0.000–0.101, P = 0.001) and Hunt and Hess Grade II (OR 0.010, 95% C.I. 0.000–0.346, P = 0.011) are identified as protective factors. Conclusions: Small aneurysms, atherosclerosis, Fisher Grade of SAH and cerebral vasospasm are the predictors of IPR. Aneurysms at proximal part of ICA bifurcation and BA stem and Hunt and Hess Grade II are less associated with IPR. Rapid completion of coiling combined with immediate reversal of heparin anticoagulation is confirmed to be the best strategy in our series.

  6. Microsurgical clipping of ophthalmic artery aneurysms: surgical results and visual outcomes with 208 aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Tabani, Halima; Safaee, Michael M; Burkhardt, Jan-Karl; Lawton, Michael T

    2018-01-26

    OBJECTIVE While most paraclinoid aneurysms can be clipped with excellent results, new postoperative visual deficits are a concern. New technology, including flow diverters, has increased the popularity of endovascular therapy. However, endovascular treatment of paraclinoid aneurysms is not without procedural risks, is associated with higher rates of incomplete aneurysm occlusion and recurrence, and may not address optic nerve compression symptoms that surgical debulking can. The increasing endovascular management of paraclinoid aneurysms should be justified by comparisons to surgical benchmarks. The authors, therefore, undertook this study to define patient, visual, and aneurysm outcomes in the most common type of paraclinoid aneurysm: ophthalmic artery (OphA) aneurysms. METHODS Results from microsurgical clipping of 208 OphA aneurysms in 198 patients were retrospectively reviewed. Patient demographics, aneurysm morphology (size, calcification, etc.), clinical characteristics, and patient outcomes were recorded and analyzed. RESULTS Despite 20% of these aneurysms being large or giant in size, complete aneurysm occlusion was accomplished in 91% of 208 cases, with OphA patency preserved in 99.5%. The aneurysm recurrence rate was 3.1% and the retreatment rate was 0%. Good outcomes (modified Rankin Scale score 0-2) were observed in 96.2% of patients overall and in all 156 patients with unruptured aneurysms. New visual field defects (hemianopsia or quadrantanopsia) were observed in 8 patients (3.8%), decreased visual acuity in 5 (2.4%), and monocular blindness in 9 (4.3%). Vision improved in 9 (52.9%) of the 17 patients with preoperative visual deficits. CONCLUSIONS The most important risk associated with clipping OphA aneurysms is a new visual deficit. Meticulous microsurgical technique is necessary during anterior clinoidectomy, aneurysm dissection, and clip application to optimize visual outcomes, and aggressive medical management postoperatively might potentially

  7. A Case of Ruptured Blood Blister-like Aneurysm Treated with Pipeline Embolization Device: Clinical Significance of Fetal-type Posterior Communicating Artery.

    Science.gov (United States)

    Park, Ki-Su; Kang, Dong-Hun; Son, Won-Soo; Park, Jaechan; Kim, Young-Sun; Kim, Byung Moon

    2017-03-01

    Blood-blister like aneurysms (BBAs) are challenging lesions because of their wide fragile neck. Flow-diverting stents (FDSs), such as the Pipeline Embolization Device (PED), have been applied to treat BBAs less amenable to more established techniques of treatment. However, the use of FDSs, including the PED, in acute subarachnoid hemorrhage (SAH) still remains controversial. We report a case of aneurysm regrowth following PED application for a ruptured BBA that overlapped the origin of the dominant posterior communicating artery (PCoA), which was successfully treated after coil trapping of the origin of the fetal-type PCoA. And, we discuss the clinical significance of the fetal-type PCoA communicating with a BBA in terms of PED failure.

  8. A periodic table of coiled-coil protein structures.

    Science.gov (United States)

    Moutevelis, Efrosini; Woolfson, Derek N

    2009-01-23

    Coiled coils are protein structure domains with two or more alpha-helices packed together via interlacing of side chains known as knob-into-hole packing. We analysed and classified a large set of coiled-coil structures using a combination of automated and manual methods. This led to a systematic classification that we termed a "periodic table of coiled coils," which we have made available at http://coiledcoils.chm.bris.ac.uk/ccplus/search/periodic_table. In this table, coiled-coil assemblies are arranged in columns with increasing numbers of alpha-helices and in rows of increased complexity. The table provides a framework for understanding possibilities in and limits on coiled-coil structures and a basis for future prediction, engineering and design studies.

  9. Blood blister-like aneurysms: Single center experience and systematic literature review

    International Nuclear Information System (INIS)

    Gonzalez, Ana Marcos; Narata, Ana Paula; Yilmaz, Hasan; Bijlenga, Philippe; Radovanovic, Ivan; Schaller, Karl; Lovblad, Karl-Olof; Pereira, Vitor Mendes

    2014-01-01

    Blood blister-like aneurysms (BBAs) are a controversial entity. They arise from non-branching sites on the supraclinoid internal carotid artery (ICA) and are suspected to originate from a dissection. Our aim is to describe the BBA cases seen in our center and to present a systematic review of the literature on BBAs. We analyzed the eleven cases of BBA admitted to our center from 2003 to 2012. We assessed the medical history, treatment modality (endovascular and/or surgery), complications and clinical outcome. The cohort included 8 women and 4 men with a mean age of 53.16 years. Treatment of the BBA consisted of stenting and coiling in 5 patients, stenting only in 4 patients, coiling and clipping in 1 patient, clipping only in 1 patient, and conservative treatment in 1 patient. A good outcome was found in 10 patients, as defined by a modified Rankin Scale (mRS) less than or equal to two at three months. A systematic review of the literature was performed, and 314 reported patients were found: 221 patients were treated with a primarily surgical approach, and 87 patients were treated with a primarily endovascular approach. A rescue or second treatment was required in 46 patients (21%). The overall estimated treatment morbidity rate was 17%, and the mortality rate was 15%. BBAs exhibit more aggressive behavior compared to saccular aneurysms, and more intra-operative complications occur with BBAs, independent of the treatment type offered. They are also significantly more likely to relapse and rebleed after treatment. Endovascular treatment offers a lower morbidity–mortality compared with surgical approaches. Multilayer flow-diverting stents appear to be a promising strategy

  10. Aneurysm in the brain

    Science.gov (United States)

    ... gov/ency/article/001414.htm Aneurysm in the brain To use the sharing features on this page, ... aneurysm occurs in a blood vessel of the brain, it is called a cerebral, or intracranial, aneurysm. ...

  11. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Directory of Open Access Journals (Sweden)

    Guilherme S. Nakiri

    2011-01-01

    Full Text Available PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1. Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1 and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1. Disagreement occurred in only one case (2.3%, which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between

  12. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  13. Combining monoenergetic extrapolations from dual-energy CT with iterative reconstructions. Reduction of coil and clip artifacts from intracranial aneurysm therapy

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, Sebastian; Baltsavias, Gerasimos; Michels, Lars; Valavanis, Antonios [University of Zurich, Department of Neuroradiology, University Hospital Zurich, Zurich (Switzerland); Hinzpeter, Ricarda; Stocker, Daniel; Alkadhi, Hatem [University of Zurich, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland); Burkhardt, Jan-Karl; Regli, Luca [University of Zurich, Department of Neurosurgery, University Hospital Zurich, Zurich (Switzerland)

    2018-03-15

    To compare and to combine iterative metal artifact reduction (MAR) and virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (DECT) for reducing metal artifacts from intracranial clips and coils. Fourteen clips and six coils were scanned in a phantom model with DECT at 100 and 150SnkVp. Four datasets were reconstructed: non-corrected images (filtered-back projection), iterative MAR, VME from DECT at 120 keV, and combined iterative MAR + VME images. Artifact severity scores and visibility of simulated, contrast-filled, adjacent vessels were assessed qualitatively and quantitatively by two independent, blinded readers. Iterative MAR, VME, and combined iterative MAR + VME resulted in a significant reduction of qualitative (p < 0.001) and quantitative clip artifacts (p < 0.005) and improved the visibility of adjacent vessels (p < 0.05) compared to non-corrected images, with lowest artifact scores found in combined iterative MAR + VME images. Titanium clips demonstrated less artifacts than Phynox clips (p < 0.05), and artifact scores increased with clip size. Coil artifacts increased with coil size but were reducible when applying iterative MAR + VME compared to non-corrected images. However, no technique improved the severe artifacts from large, densely packed coils. Combining iterative MAR with VME allows for an improved metal artifact reduction from clips and smaller, loosely packed coils. Limited value was found for large and densely packed coils. (orig.)

  14. Brain aneurysm repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000123.htm Brain aneurysm repair - discharge To use the sharing features ... this page, please enable JavaScript. You had a brain aneurysm . An aneurysm is a weak area in ...

  15. Influence of endoleaks on aneurysm volume and hemodynamics after endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Pitton, M.B.; Welter, B.; Schmenger, P.; Thelen, M.; Dueber, C.; Neufang, A.

    2003-01-01

    Purpose: To evaluate the aneurysm volume and the intra-aneurysmatic pressure and maximal pressure pulse (dp/dtmax) in completely excluded aneurysms and cases with endoleaks. Materials and Methods: In 36 mongrel dogs, experimental autologous aneurysms were treated with stent-grafts. All aortic side branches were ligated in 18 cases (group I) but were preserved in group II (n=18). Aneurysm volumes were calculated from CT scans before and after intervention, and from follow-up CT scans at 1 week, 6 weeks and 6 months. Finally, for hemodynamic measurements, manometer-tipped catheters were introduced into the excluded aneurysm sac (group I and II), selectively in endoleaks (group II), and intraluminally for aortic reference measurement. Systemic hypertension was induced by volume load and pharmacologic stress. Pressure curves and dp/dt were simultaneously recorded and the ratios of aneurysm pressure to systemic reference pressure calculated. Results: At follow-up, type-II, endoleaks were excluded in all cases of group I by selective angiography. In contrast, endoleaks were evident in all cases of group II. Volumetric analysis of the aneurysms showed a benefit for group I with an improved aneurysm shrinkage: ΔVolume +0.08%, -1.62% and -9.76% at 1 week, 6 weeks and 6 months follow-up (median, group I), compared to +1.43%, +0.67%, and -4.04% (group II), p [de

  16. Hepatobiliary fascioliasis with multiple aneurysms and active bleeding: A case report

    International Nuclear Information System (INIS)

    Choi, Soo Young; Kim Jae Woon; Jang, Jae Cheon

    2015-01-01

    A 52-year-old woman visited our institution with upper abdominal pain which had lasted for the past two days. Laboratory tests revealed mild leukocytosis, decreased serum hemoglobin, and peripheral blood eosinophilia. CT scans showed multiple ill-defined, hypodense lesions in the peripheral areas of both hepatic lobes and active bleeding with a subcapsular hematoma in the right hepatic lobe. Angiography also showed active bleeding in the right hepatic lobe with multiple aneurysms, so a transarterial coil embolization was performed to stop the bleeding. The endoscopic retrograde cholangiopancreatography revealed several moving flat flukes in the common bile duct, which were pathologically confirmed as Fasciola hepatica.

  17. Hepatobiliary fascioliasis with multiple aneurysms and active bleeding: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soo Young; Kim Jae Woon; Jang, Jae Cheon [Dept. of Radiology, College of Medicine, Yeungnam University, Daegu (Korea, Republic of)

    2015-04-15

    A 52-year-old woman visited our institution with upper abdominal pain which had lasted for the past two days. Laboratory tests revealed mild leukocytosis, decreased serum hemoglobin, and peripheral blood eosinophilia. CT scans showed multiple ill-defined, hypodense lesions in the peripheral areas of both hepatic lobes and active bleeding with a subcapsular hematoma in the right hepatic lobe. Angiography also showed active bleeding in the right hepatic lobe with multiple aneurysms, so a transarterial coil embolization was performed to stop the bleeding. The endoscopic retrograde cholangiopancreatography revealed several moving flat flukes in the common bile duct, which were pathologically confirmed as Fasciola hepatica.

  18. Large coil task and results of testing US coils

    International Nuclear Information System (INIS)

    Haubenreich, P.N.

    1986-01-01

    The United States, EURATOM, Japan, and Switzerland have collaborated since 1978 in development of superconducting toroidal field coils for fusion reactor applications. The United States provided a test facility nd three coils; the other participants, one coil each. All coils have the same interface dimensions and performance requirements (stable at 8 T), but internal design was decided by each team. Two US coil teams chose bath-cooled NbTi, 10-kA conductors. One developed a Nb 3 Sn conductor, cooled by internal flow, rated at 18 kA. All US coils have diagnostic instrumentation and imbedded heaters that enable stability tests and simulated nuclear heating experiments. In single-coil tests, each coil operated at full current in self-field (6.4 T). In six-coil tests that began in July 1986, one US coil and the Japanese coil hve been successfully operated at full current at 8 T. The other coils have operated as background coils while awaiting their turn as test coil. Coil tests have been informative and results gratifying. The facility has capably supported coil testing and its operation has provided information that will be useful in designing future fusion systems. Coil capabilities beyond nominal design points will be determined

  19. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Huang Sheng; Jing Zaiping; Mei Zhijun; Lu Qingsheng; Zhao Jun; Zhang Suzhen; Zhao Xin; Cai Lili; Tang Jingdong; Xiong Jiang; Liao Mingfang

    2003-01-01

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  20. Aneurysm occlusion in elderly patients with aneurysmal subarachnoid haemorrhage : a cost-utility analysis

    NARCIS (Netherlands)

    Koffijberg, H.; Buskens, E.; Rinkel, G. J. E.

    Background Aneurysm occlusion after subarachnoid haemorrhage (SAH) aims to improve outcome by reducing the rebleeding risk. With increasing age, overall prognosis decreases, and the complications of aneurysm occlusion increase. The balance of risks for aneurysm occlusion in elderly SAH patients in

  1. Brain Aneurysm: Treatment Options

    Science.gov (United States)

    ... inoperable aneurysms. Decisions regarding management of an unruptured brain aneurysm are based on the careful comparison of the short- and ... so Tired? How Do I Deal With Depression? Learning Principles to Aid Recovery The Memory Book ... Aneurysm Foundation Support Community Research & Grants BAF Research ...

  2. Difference in aneurysm characteristics between patients with familial and sporadic aneurysmal subarachnoid haemorrhage

    NARCIS (Netherlands)

    Mensing, Liselore A.; Rinkel, Gabriel J E; Vlak, Monique H M; Van Der Schaaf, Irene C.; Ruigrok, Ynte M.

    2016-01-01

    Object Patients with familial intracranial aneurysms (IA) have a higher risk of rupture than patients with sporadic IA. We compared geometric and morphological risk factors for aneurysmal rupture between patients with familial and sporadic aneurysmal subarachnoid hemorrhage (aSAH) to analyse if

  3. Ex vivo repair of renal artery aneurysm associated with surgical treatment of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kostić Dušan M.

    2004-01-01

    Full Text Available INTRODUCTION Renal artery aneurysms is relatively uncommon with reported incidence ranges from 0.3% to 1%. However, considering all visceral artery aneurysms the percentage of renal artery aneurysms is relatively high between 15-25%. The distal forms of renal artery aneurysms sometimes require "ex vivo" reconstruction and kidney autotransplantation. CASE REPORT A 75-year-old male presented with the right abdominal and back pain. He suffered from a long history of arterial hypertension and chronic renal failure over the last few months (urea blood = 19.8 mmol/l; creatinine = 198 mmol/l. Duplex ultrasonography showed abdominal aortic aneurysm. Subsequent translumbarangiography revealed juxtarenal abdominal aortic aneurysm associated with distal right renal artery aneurysm. The operation was performed under combined thoracic epidural analgesia and general anesthesia using transperitoneal approach. After the laparotomy, the ascending colon was mobilized and reflected medially followed by Kocher maneuver. The result was visualization of the anterior aspect of the right kidney, the collecting system, ureter as well as the right renal vein and artery with large saccular aneurysm located distally. After mobilization of the renal vessels and careful dissection of the ureter, the kidney was explanted. The operation was continued by two surgical teams. The first team performed abdominal aortic aneurysm resection and reconstruction with bifurcated Dacron graft. The second team performed ex vivo reparation of renal artery aneurysm. All time during the explantation, the kidney was perfused by Collins' solution. The saccular right renal artery aneurysm 4 cm in diameter was located at the kidney hilus at the first bifurcation. Three branches originated from the aneurysm. The aneurysm was resected completely. The longest and widest of three branches arising from the aneurysmal sac was end-to-end anastomized with 6 mm PTFE graft. After this intervention, one of

  4. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  5. Pulmonary Artery Aneurysm/Pseudoaneurysm, a Delayed Complication of Lung Abscess: A Case Report.

    Science.gov (United States)

    Oguma, Tsuyoshi; Morise, Masahiro; Harada, Kazuki; Tanaka, Jun; Sato, Masako; Horio, Yukihiro; Takiguchi, Hiroto; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Takihara, Takahisa; Niimi, Kyoko; Hayama, Naoki; Aoki, Takuya; Urano, Tetsuya; Ito, Chihiro; Koizumi, Jun; Asano, Koichiro

    2015-09-20

    Massive hemoptysis mostly arises from the bronchial arteries; however, bleeding can also occur from a lesion in injured pulmonary arteries, such as pulmonary artery aneurysm/pseudoaneurysm (PAA/PAP), during pulmonary infection. A 66-year-old man was admitted with a diagnosis of lung abscess in the right lower lobe that was complicated with pyothorax. Intravenous administration of antibiotics and thoracic drainage successfully controlled the infection and inflammation until day 16, when the patient began to exhibit hemoptysis and bloody pleural effusion. Enhanced computed tomography (CT) with multi-planer reconstruction (MPR) images showed a highly enhanced mass inside the abscess fed by the pulmonary artery, suggesting PAA/PAP. Pulmonary angiography confirmed PAA/PAP, and embolization with coils successfully stopped both the bleeding into the sputum and pleural effusion, with a collapsed aneurysm visible on chest CT scan. Clinicians should consider the possibility of PAA/PAP in the differential diagnosis of hemoptysis during the treatment of patients with lung abscess. MPR CT is helpful for the diagnosis of PAA/PAP and its feeding vessels.

  6. Brain Aneurysm Statistics and Facts

    Science.gov (United States)

    ... Statistics and Facts A- A A+ Brain Aneurysm Statistics and Facts An estimated 6 million people in ... Understanding the Brain Warning Signs/ Symptoms Brain Aneurysm Statistics and Facts Seeking Medical Attention Risk Factors Aneurysm ...

  7. Extending the self-assembly of coiled-coil hybrids

    NARCIS (Netherlands)

    Robson Marsden, Hana

    2009-01-01

    Of the various biomolecular building blocks in use in nature, coiled-coil forming peptides are amongst those with the most potential as building blocks for the synthetic self-assembly of nanostructures. Native coiled coils have the ability to function in, and influence, complex systems composed of

  8. Vascular Variations Associated with Intracranial Aneurysms.

    Science.gov (United States)

    Orakdogen, Metin; Emon, Selin Tural; Somay, Hakan; Engin, Taner; Is, Merih; Hakan, Tayfun

    2017-01-01

    To investigate the vascular variations in patients with intracranial aneurysm in circle of Willis. We used the data on 128 consecutive intracranial aneurysm cases. Cerebral angiography images were analyzed retrospectively. Arteries were grouped as anterior cerebral arterial system (ACS), posterior cerebral arterial system (PCS) and middle cerebral arterial system (MCS) for grouping vascular variations. Lateralization, being single/multiple, gender; and also any connection with accompanying aneurysms" number, localization, dimension, whether bleeding/incidental aneurysm has been inspected. Variations were demonstrated in 57.8% of the cases. The most common variation was A1 variation (34.4%). The rate of variations was 36.7%, 24.2% and 10.2% respectively in ACS, PCS and MCS. MCS variations were significantly higher in males. Anterior communicating artery (ACoA) aneurysm observance rates were significantly higher and posterior communicating artery (PCoA) aneurysm and middle cerebral artery (MCA) aneurysm observance rates were significantly lower when compared to "no ACS variation detected" cases. In "PCS variation detected" cases, PCoA aneurysm observance rates and coexistence of multiple variations were significantly higher. The rate of vascular variations in patients with aneurysms was 57.8%. Arterial hypoplasia and aplasia were the most common variations. ACS was the most common region that variations were located in; they were mostly detected on the right side. Coexistence of ACoA aneurysm was higher than PCoA and MCA aneurysms. In the PCS variations group, PCoA aneurysms were the most common aneurysms that accompanying the variation and multiple variations were more common than in the other two groups. The variations in MCS were most common in males.

  9. The influence of atmospheric pressure on aortic aneurysm rupture--is the diameter of the aneurysm important?

    Science.gov (United States)

    Urbanek, Tomasz; Juśko, Maciej; Niewiem, Alfred; Kuczmik, Wacław; Ziaja, Damian; Ziaja, Krzysztof

    2015-01-01

    The rate of aortic aneurysm rupture correlates with the aneurysm's diameter, and a higher rate of rupture is observed in patients with larger aneurysms. According to the literature, contradictory results concerning the relationship between atmospheric pressure and aneurysm size have been reported. In this paper, we assessed the influence of changes in atmospheric pressure on abdominal aneurysm ruptures in relationship to the aneurysm's size. The records of 223 patients with ruptured abdominal aneurysms were evaluated. All of the patients had been admitted to the department in the period 1997-2007 from the Silesia region. The atmospheric pressures on the day of the rupture and on the days both before the rupture and between the rupture events were compared. The size of the aneurysm was also considered in the analysis. There were no statistically significant differences in pressure between the days of rupture and the remainder of the days within an analysed period. The highest frequency of the admission of patients with a ruptured aortic aneurysm was observed during periods of winter and spring, when the highest mean values of atmospheric pressure were observed; however, this observation was not statistically confirmed. A statistically non-significant trend towards the higher rupture of large aneurysms (> 7 cm) was observed in the cases where the pressure increased between the day before the rupture and the day of the rupture. This trend was particularly pronounced in patients suffering from hypertension (p = 0.1). The results of this study do not support the hypothesis that there is a direct link between atmospheric pressure values and abdominal aortic aneurysm ruptures.

  10. Technical Assessment of Artifact Production from Neuro Endovascular Coil At 3 Tesla MRI: An In Vitro Study

    International Nuclear Information System (INIS)

    Kampaengtip, A.; Krisanachinda, A.; Singhara Na Ayudya, S.; Asavaphatiboon, S.

    2012-01-01

    Introduction: Magnetic resonance imaging (MRI) is an essential part of the diagnostic procedures in radiology. MRI 3 Tesla becomes more widespread due to high signal to noise ratio (SNR). The use of the neuro endovascular coil to overcome the neuro aneurysm can introduce the artifact in magnetic resonance imaging. Susceptibility artifacts and geometric distortions caused by magnetic field inhomogeneity- related signal loss is used to refer to an artifact in magnetic resonance images. It consists of a region of signal void with a surrounding area of an increased signal intensity that appears to be considerably larger than the actual size of the device causing the artifact. The objective of the study is to compare the size of the artifact on the MR image to the actual size of endovascular coils using a 3 Tesla magnetic resonance imaging system, in vitro study. Methods: The endovascular coils were made from detachable platinum and aneurysm models were constructed by using silicone tube. MRI 3 Tesla Philips Model Achieva with pulse sequence selections were: spin echo, fast spin echo, inversion recovery, fast gradient echo while additional parameters were echo time and turbo factor. Results: Improved visualization of perianeurysmal soft tissues is best accomplished by spin echo for fast spin echo sequences, even better suited to reduce metal artifact. Furthermore, shorter turbo factor and shorter effective TE in the latter sequences are beneficial for the same reason as sequences having shorter TE. Sequences with a shorter TE are preferred because of less time for dephasing and frequency shifting. Imaging at gradient echo series increases susceptibility artifacts. In this in vitro study, some of the major characteristics related to MRI imaging of coil packs have been defined. Discussion: Pulse sequence spin echo is the best sequence reducing the susceptibility artifact. Reducing the TE is the main factor in improving endovascular coil visualization on MRI images. The

  11. TGFβ (Transforming Growth Factor-β) Blockade Induces a Human-Like Disease in a Nondissecting Mouse Model of Abdominal Aortic Aneurysm.

    Science.gov (United States)

    Lareyre, Fabien; Clément, Marc; Raffort, Juliette; Pohlod, Stefanie; Patel, Meghana; Esposito, Bruno; Master, Leanne; Finigan, Alison; Vandestienne, Marie; Stergiopulos, Nikolaos; Taleb, Soraya; Trachet, Bram; Mallat, Ziad

    2017-11-01

    Current experimental models of abdominal aortic aneurysm (AAA) do not accurately reproduce the major features of human AAA. We hypothesized that blockade of TGFβ (transforming growth factor-β) activity-a guardian of vascular integrity and immune homeostasis-would impair vascular healing in models of nondissecting AAA and would lead to sustained aneurysmal growth until rupture. Here, we test this hypothesis in the elastase-induced AAA model in mice. We analyze AAA development and progression using ultrasound in vivo, synchrotron-based ultrahigh resolution imaging ex vivo, and a combination of biological, histological, and flow cytometry-based cellular and molecular approaches in vitro. Systemic blockade of TGFβ using a monoclonal antibody induces a transition from a self-contained aortic dilatation to a model of sustained aneurysmal growth, associated with the formation of an intraluminal thrombus. AAA growth is associated with wall disruption but no medial dissection and culminates in fatal transmural aortic wall rupture. TGFβ blockade enhances leukocyte infiltration both in the aortic wall and the intraluminal thrombus and aggravates extracellular matrix degradation. Early blockade of IL-1β or monocyte-dependent responses substantially limits AAA severity. However, blockade of IL-1β after disease initiation has no effect on AAA progression to rupture. Endogenous TGFβ activity is required for the healing of AAA. TGFβ blockade may be harnessed to generate new models of AAA with better relevance to the human disease. We expect that the new models will improve our understanding of the pathophysiology of AAA and will be useful in the identification of new therapeutic targets. © 2017 American Heart Association, Inc.

  12. Ruptured submitral aneurysm

    Directory of Open Access Journals (Sweden)

    V. Shukla

    2016-09-01

    Full Text Available Submitral aneurysm is a rare entity, with around few hundred cases reported till date. Presentation can be varied. We describe here a case of submitral aneurysm in a young male with rupture into the left atrium cavity.

  13. Evaluation of Aneurysm Neck Angle Change After Endovascular Aneurysm Repair Clinical Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Le, Trong Binh; Moon, Mi Hyoung [Inha University Hospital, Endovascular Training Center (Korea, Republic of); Jeon, Yong Sun, E-mail: radjeon@inha.ac.kr [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Hong, Kee Chun [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of); Cho, Soon Gu [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Park, Keun-Myoung [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of)

    2016-05-15

    PurposeTo evaluate the aneurysm neck angle changes and post-endovascular aneurysm repair (EVAR) complications.MethodsWe retrospectively analyzed 72 cases of elective EVAR for abdominal aortic aneurysm among 109 consecutive cases from December 2005 to April 2014. Patients were divided into angulated and non-angulated groups. The angulated group was defined as neck angulation ≥60°. Neck angle was evaluated pre- and post-EVAR during short- (within 1 month), mid- (3–6 months), and long-term (>1 year) follow-up. Aneurysm sac diameter change, aneurysm neck morphology other than angulation, endoleaks, and other post-procedural complications were also documented.ResultsA total of 34 patients were enrolled in the angulated group. There were no statistical differences in age, sex, follow-up duration, and aneurysm neck profile between the two groups (p > 0.05). Both groups showed statistically significant and consistent decreases in angulation during the follow-up period (p < 0.01). The angulated group revealed 22.45 % more straightening than the non-angulated group. Recoil of the Endurant device occurred in the angulated group. No statistically significant intergroup differences were observed in any endoleaks, complications, or re-intervention rates (p > 0.05). Pre-EVAR angle was the only predictor for post-procedural angle change (p < 0.001).ConclusionEVAR is applicable for patients with highly angulated aneurysm neck and provides consistent neck straightening over long-term follow-up. Recoil was evident in the angulated group using the Endurant device.

  14. Impact of Clipping versus Coiling on Postoperative Hemodynamics and Pulmonary Edema after Subarachnoid Hemorrhage

    Directory of Open Access Journals (Sweden)

    Nobutaka Horie

    2014-01-01

    Full Text Available Volume management is critical for assessment of cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH. This multicenter prospective cohort study compared the impact of surgical clipping versus endovascular coiling on postoperative hemodynamics and pulmonary edema in patients with SAH. Hemodynamic parameters were measured for 14 days using a transpulmonary thermodilution system. The study included 202 patients, including 160 who underwent clipping and 42 who underwent coiling. There were no differences in global ejection fraction (GEF, cardiac index, systemic vascular resistance index, or global end-diastolic volume index between the clipping and coiling groups in the early period. However, extravascular lung water index (EVLWI and pulmonary vascular permeability index (PVPI were significantly higher in the clipping group in the vasospasm period. Postoperative C-reactive protein (CRP level was higher in the clipping group and was significantly correlated with postoperative brain natriuretic peptide level. Multivariate analysis found that PVPI and GEF were independently associated with high EVLWI in the early period, suggesting cardiogenic edema, and that CRP and PVPI, but not GEF, were independently associated with high EVLWI in the vasospasm period, suggesting noncardiogenic edema. In conclusion, clipping affects postoperative CRP level and may thereby increase noncardiogenic pulmonary edema in the vasospasm period. His trial is registered with University Hospital Medical Information Network UMIN000003794.

  15. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  16. Is Internal Iliac Artery Embolization Essential Prior to Endovascular Repair of Aortoiliac Aneurysms?

    International Nuclear Information System (INIS)

    Bharwani, N.; Raja, J.; Choke, E.; Belli, A. M.; Thompson, M. M.; Morgan, R. A.; Munneke, G.

    2008-01-01

    Patients who undergo endovascular repair of aorto-iliac aneurysms (EVAR) require internal iliac artery (IIA) embolization (IIAE) to prevent type II endoleaks after extending the endografts into the external iliac artery. However, IIAE may not be possible in some patients due to technical factors or adverse anatomy. The aim of this study was to assess retrospectively whether patients with aorto-iliac aneurysms who fail IIAE have an increase in type II endoleak after EVAR compared with similar patients who undergo successful embolization. We retrospectively analyzed the records of 148 patients who underwent EVAR from December 1997 to June 2005. Sixty-one patients had aorto-iliac aneurysms which required IIAE before EVAR. Fifty patients had successful IIAE and 11 patients had unsuccessful IIAE prior to EVAR. The clinical and imaging follow-up was reviewed before and after EVAR. The endoleak rate of the embolized group was compared with that of the group in whom embolization failed. After a mean follow-up of 19.7 months in the study group and 25 months in the control group, there were no statistically significant differences in outcome measures between the two groups. Specifically, there were no type II endoleaks related to the IIA in patients where IIAE had failed. We conclude that failure to embolize the IIA prior to EVAR should not necessarily preclude patients from treatment. In patients where there is difficulty in achieving coil embolization, it is recommended that EVAR should proceed, as clinical sequelae are unlikely

  17. Transcatheter Embolisation of Proximal Type 1 Endoleaks Following Endovascular Aneurysm Sealing (EVAS) Using the Nellix Device: Technique and Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Ameli-Renani, S., E-mail: seyedameli@doctors.org.uk; Morgan, R. A., E-mail: Robert.morgan@stgeorges.nhs.uk [St George’s Hospital, Department of Radiology (United Kingdom)

    2015-10-15

    AimTo evaluate the technical success and mid-term outcomes following transcatheter embolisation of type 1a endoleak after Nellix endovascular aneurysm sealing (EVAS).Materials and MethodsSeven patients (5 men; mean age 83; range 79–90) underwent transcatheter embolisation between July 2013 and August 2014. The average time from EVAS to embolisation was 136 days (range 6–301) and from endoleak diagnosis to embolisation was 20 days (range 2–50). Embolisation was performed with coils and Onyx in six cases and Onyx only in one case. Technical success, imaging and clinical outcomes of embolisation were reviewed. Technical success was defined as elimination of the endoleak on completion angiography and first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up (average 8 months; range 103–471 days).ResultsAll cases were technically successful. One patient required a second endovascular procedure following Onyx reflux into the Nellix endograft and another patient required surgical closure of a brachial puncture site. All patients are endoleak free with stable sac size on the latest available follow-up imaging.ConclusionIf a type 1 endoleak occurs after EVAS, embolisation using Onyx with or without coils is feasible and effective with high technical success and freedom from endoleak recurrence at mid-term follow-up.

  18. Transcatheter Embolisation of Proximal Type 1 Endoleaks Following Endovascular Aneurysm Sealing (EVAS) Using the Nellix Device: Technique and Outcomes

    International Nuclear Information System (INIS)

    Ameli-Renani, S.; Morgan, R. A.

    2015-01-01

    AimTo evaluate the technical success and mid-term outcomes following transcatheter embolisation of type 1a endoleak after Nellix endovascular aneurysm sealing (EVAS).Materials and MethodsSeven patients (5 men; mean age 83; range 79–90) underwent transcatheter embolisation between July 2013 and August 2014. The average time from EVAS to embolisation was 136 days (range 6–301) and from endoleak diagnosis to embolisation was 20 days (range 2–50). Embolisation was performed with coils and Onyx in six cases and Onyx only in one case. Technical success, imaging and clinical outcomes of embolisation were reviewed. Technical success was defined as elimination of the endoleak on completion angiography and first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up (average 8 months; range 103–471 days).ResultsAll cases were technically successful. One patient required a second endovascular procedure following Onyx reflux into the Nellix endograft and another patient required surgical closure of a brachial puncture site. All patients are endoleak free with stable sac size on the latest available follow-up imaging.ConclusionIf a type 1 endoleak occurs after EVAS, embolisation using Onyx with or without coils is feasible and effective with high technical success and freedom from endoleak recurrence at mid-term follow-up

  19. Dilute self-healing hydrogels of silk-collagen-like block copolypeptides at neutral pH

    NARCIS (Netherlands)

    Golinska, M.D.; Wlodarczyk-Biegun, M.K.; Werten, M.W.T.; Cohen Stuart, M.A.; Wolf, de F.A.; Vries, de R.J.

    2014-01-01

    We report on self-healing, pH-responsive hydrogels that are entirely protein-based. The protein is a denovo designed recombinant triblock polypeptide of 66 kg/mol consisting of a silk-like middle block (GAGAGAGH)48, flanked by two long collagen-inspired hydrophilic random coil side blocks. The

  20. Time Course of Cerebrovascular Reactivity in Patients Treated for Unruptured Intracranial Aneurysms: A One-Year Transcranial Doppler and Acetazolamide Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Marianne Lundervik Bøthun

    2018-01-01

    Full Text Available Background. Cerebrovascular reactivity (CVR is often impaired in the early phase after aneurysmal subarachnoid hemorrhage. There is, however, little knowledge about the time course of CVR in patients treated for unruptured intracranial aneurysms (UIA. Methods. CVR, assessed by transcranial Doppler and acetazolamide test, was examined within the first postoperative week after treatment for UIA and reexamined one year later. Results. Of 37 patients initially assessed, 34 were reexamined after one year. Bilaterally, baseline and acetazolamide-induced blood flow velocities were higher in the postoperative week compared with one year later (p<0.001. CVR on the ipsilateral side of treatment was lower in the initial examination compared with follow-up (58.9% versus 66.1%, p=0.04. There was no difference in CVR over time on the contralateral side (63.4% versus 65.0%, p=0.65. When mean values of right and left sides were considered there was no difference in CVR between exams. Larger aneurysm size was associated with increased change in CVR (p=0.04, and treatment with clipping was associated with 13.8%-point increased change in CVR compared with coiling (p=0.03. Conclusion. Patients with UIA may have a temporary reduction in CVR on the ipsilateral side after aneurysm treatment. The change in CVR appears more pronounced for larger-sized aneurysms and in patients treated with clipping. We recommend that ipsilateral and contralateral CVR should be assessed separately, as mean values can conceal side-differences.

  1. Modular coils: a promising toroidal-reactor-coil system

    International Nuclear Information System (INIS)

    Chu, T.K.; Furth, H.P.; Johnson, J.L.; Ludescher, C.; Weimer, K.E.

    1981-04-01

    The concept of modular coils originated from a need to find reactor-relevant stellarator windings, but its usefulness can be extended to provide an externally applied, additional rotational transform in tokamaks. Considerations of (1) basic principles of modular coils, (2) types of coils, (3) types of configurations (general, helically symmetric, helically asymmetric, with magnetic well, with magnetic hill), (4) types of rotational transform profile, and (5) structure and origin of ripples are given. These results show that modular coils can offer a wide range of vacuum magnetic field configurations, some of which cannot be obtained with the classical stellarator or torsatron coil configuration

  2. Primary extracranial vertebral artery aneurysms.

    Science.gov (United States)

    Morasch, Mark D; Phade, Sachin V; Naughton, Peter; Garcia-Toca, Manuel; Escobar, Guillermo; Berguer, Ramon

    2013-05-01

    Extracranial vertebral artery aneurysms are uncommon and are usually associated with trauma or dissection. Primary cervical vertebral aneurysms are even rarer and are not well described. The presentation and natural history are unknown and operative management can be difficult. Accessing aneurysms at the skull base can be difficult and, because the frail arteries are often afflicted with connective tissue abnormalities, direct repair can be particularly challenging. We describe the presentation and surgical management of patients with primary extracranial vertebral artery aneurysms. In this study we performed a retrospective, multi-institutional review of patients with primary aneurysms within the extracranial vertebral artery. Between January 2000 and January 2011, 7 patients, aged 12-56 years, were noted to have 9 primary extracranial vertebral artery aneurysms. All had underlying connective tissue or another hereditary disorder, including Ehler-Danlos syndrome (n=3), Marfan's disease (n=2), neurofibromatosis (n=1), and an unspecified connective tissue abnormality (n=1). Eight of 9 aneurysms were managed operatively, including an attempted bypass that ultimately required vertebral ligation; the contralateral aneurysm on this patient has not been treated. Open interventions included vertebral bypass with vein, external carotid autograft, and vertebral transposition to the internal carotid artery. Special techniques were used for handling the anastomoses in patients with Ehler-Danlos syndrome. Although endovascular exclusion was not performed in isolation, 2 hybrid procedures were performed. There were no instances of perioperative stroke or death. Primary extracranial vertebral artery aneurysms are rare and occur in patients with hereditary disorders. Operative intervention is warranted in symptomatic patients. Exclusion and reconstruction may be performed with open and hybrid techniques with low morbidity and mortality. Copyright © 2013 Elsevier Inc. All rights

  3. MR angiography of cerebral aneurysms

    International Nuclear Information System (INIS)

    Miki, Hitoshi; Tanada, Shuji; Sakaki, Saburo; Hamamoto, Ken; Sadamoto, Kazuhiko.

    1992-01-01

    Time-of-flight (TOF) MR angiography (MRA) and phase-contrast (PC) MRA are examined clinically for evaluating cerebral aneurysms. In the morphological diagnosis of cerebral aneurysms, three-dimensional (3D) MRA is superior to two-dimensional (2D) MRA because 3D MRA has a higher S/N ratio and a higher spatial resolution. However, it is difficult to decide which, 3D TOF MRA or 3D PC MRA, is superior, for both methods have many scan parameters. In our study, 3D PC MRA was performed using two methods; one had the same acquisition time as 3D TOF MRA, while the other had the same spatial resolution as 3D TOF MRA. The detectability of aneurysms by each MRA method was evaluated in comparison with 3D TOF MRA. In fifteen patients (6 males and 9 females), a total of 16 cerebral aneurysms (3 ruptured and 13 unruptured) were studied. The lesion sizes ranged from 2.5 to 18 mm. All the 16 lesions were examined by means of 3D TOF MRA, 3D PC MRA, and conventional angiography. MR imaging was performed with a 1.5 tesla MRI system (Signa). All of the 16 cerebral aneurysms were detected by 3D TOF MRA, while only 11 of them were detected by 3D PC MRA. When 3D PC MRA was performed with the same acquisition time as 3D TOF MRA, 3D PC MRA was superior in showing one of the 7 aneurysms. When 3D PC MRA was performed with same spatial resolution as 3D TOF MRA, 3D PC MRA was superior in showing two of the 10 aneurysms. 3D TOF MRA was superior to 3D PC MRA in the detection of cerebral aneurysms because of the long acquisition times and the different flow velocity, which induced different signal intensities between the aneurysms and parent arteries in 3D PC MRA. 3D PC MRA was superior to 3D TOF MRA in patients with large thrombotic aneurysms of the internal carotid artery. We consider that 3D TOF MRA should be the first choice for screening and following-up cerebral aneurysms. 3D PC MRA should then be performed for large cerebral aneurysms in addition to 3D TOF MRA. (author)

  4. Morphological parameters associated with ruptured posterior communicating aneurysms.

    Science.gov (United States)

    Ho, Allen; Lin, Ning; Charoenvimolphan, Nareerat; Stanley, Mary; Frerichs, Kai U; Day, Arthur L; Du, Rose

    2014-01-01

    The rupture risk of unruptured intracranial aneurysms is known to be dependent on the size of the aneurysm. However, the association of morphological characteristics with ruptured aneurysms has not been established in a systematic and location specific manner for the most common aneurysm locations. We evaluated posterior communicating artery (PCoA) aneurysms for morphological parameters associated with aneurysm rupture in that location. CT angiograms were evaluated to generate 3-D models of the aneurysms and surrounding vasculature. Univariate and multivariate analyses were performed to evaluate morphological parameters including aneurysm volume, aspect ratio, size ratio, distance to ICA bifurcation, aneurysm angle, vessel angles, flow angles, and vessel-to-vessel angles. From 2005-2012, 148 PCoA aneurysms were treated in a single institution. Preoperative CTAs from 63 patients (40 ruptured, 23 unruptured) were available and analyzed. Multivariate logistic regression revealed that smaller volume (p = 0.011), larger aneurysm neck diameter (0.048), and shorter ICA bifurcation to aneurysm distance (p = 0.005) were the most strongly associated with aneurysm rupture after adjusting for all other clinical and morphological variables. Multivariate subgroup analysis for patients with visualized PCoA demonstrated that larger neck diameter (p = 0.018) and shorter ICA bifurcation to aneurysm distance (p = 0.011) were significantly associated with rupture. Intracerebral hemorrhage was associated with smaller volume, larger maximum height, and smaller aneurysm angle, in addition to lateral projection, male sex, and lack of hypertension. We found that shorter ICA bifurcation to aneurysm distance is significantly associated with PCoA aneurysm rupture. This is a new physically intuitive parameter that can be measured easily and therefore be readily applied in clinical practice to aid in the evaluation of patients with PCoA aneurysms.

  5. CCHMM_PROF: a HMM-based coiled-coil predictor with evolutionary information

    DEFF Research Database (Denmark)

    Bartoli, Lisa; Fariselli, Piero; Krogh, Anders

    2009-01-01

    tools are available for predicting coiled-coil domains in protein sequences, including those based on position-specific score matrices and machine learning methods. RESULTS: In this article, we introduce a hidden Markov model (CCHMM_PROF) that exploits the information contained in multiple sequence...... alignments (profiles) to predict coiled-coil regions. The new method discriminates coiled-coil sequences with an accuracy of 97% and achieves a true positive rate of 79% with only 1% of false positives. Furthermore, when predicting the location of coiled-coil segments in protein sequences, the method reaches...

  6. Operative and endovascular management of extracranial vertebral artery aneurysm in Ehlers-Danlos syndrome:a clinical dilemma--case report and literature review.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2002-01-01

    The most prevalent lesion of the vertebral artery is an atheromatous plaque located at its origin from the subclavian artery. A case of successful management of a symptomatic vertebral artery aneurysm due to Ehlers-Danlos syndrome is reported. The patient had asymptomatic posterior intracerebral artery dissection on the contralateral side. A common carotid artery to V-3 segment bypass using reversed saphenous vein graft was carried out. Avulsion of the V-2 segment occurred peroperatively and endovascular coil embolization of the vertebral artery aneurysm was performed. Endovascular equipment and training must be in the armamentarium of vascular surgeons as more complex cases are being treated, which demands new approaches for ultimate clinical success. This unique case outlines what might unexpectedly occur. Endovascular intervention as an adjuvant procedure provides a satisfactory outcome in what could have been a catastrophe.

  7. Giant true celiac artery aneurysm

    International Nuclear Information System (INIS)

    Aljabri, Badr

    2009-01-01

    Celiac artery aneurysms are rare and usually asymptomatic. The management of these aneurysms is challenging, especially when they are large and involve the confluence of the trifurcation. We present here a case of a large celiac artery aneurysm involving its branches in a young woman. Preoperative investigations, intraoperative findings, and the operative procedure are also presented and discussed. (author

  8. Elastin-derived peptides promote abdominal aortic aneurysm formation by modulating M1/M2 macrophage polarization1

    Science.gov (United States)

    Dale, Matthew A; Xiong, Wanfen; Carson, Jeffrey S; Suh, Melissa K; Karpisek, Andrew D.; Meisinger, Trevor M.; Casale, George P.; Baxter, B. Timothy

    2016-01-01

    Abdominal aortic aneurysm (AAA) is a dynamic vascular disease characterized by inflammatory cell invasion and extracellular matrix (ECM) degradation. Damage to elastin in the ECM results in release of elastin-derived peptides (EDPs), which are chemotactic for inflammatory cells such as monocytes. Their effect on macrophage polarization is less well known. Pro-inflammatory M1 macrophages initially are recruited to sites of injury but, if their effects are prolonged, they can lead to chronic inflammation that prevents normal tissue repair. Conversely, anti-inflammatory M2 macrophages reduce inflammation and aid in wound healing. Thus, a proper M1/M2 ratio is vital for tissue homeostasis. AAA tissue reveals a high M1/M2 ratio where pro-inflammatory cells and their associated markers dominate. In the present study, in vitro treatment of bone marrow-derived macrophages with EDPs induced M1 macrophage polarization. By using C57Bl/6 mice, antibody-mediated neutralization of EDPs reduced aortic dilation, matrix metalloproteinase activity, and pro-inflammatory cytokine expression at early and late time points after aneurysm induction. Furthermore, direct manipulation of the M1/M2 balance altered aortic dilation. Injection of M2 polarized macrophages reduced aortic dilation after aneurysm induction. EDPs promoted a pro-inflammatory environment in aortic tissue by inducing M1 polarization and neutralization of EDPs attenuated aortic dilation. The M1/M2 imbalance is vital to aneurysm formation. PMID:27183603

  9. Early Enlargement of Aneurysmal Sac and Separation of EndoBags of Nellix Endovascular Aneurysm Sealing System as Signs of Increased Risk of Later Aneurysm Rupture

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Lik Fai, E-mail: rickieclf@yahoo.com.hk [Princess Margaret Hospital, Department of Radiology (China); Cheung, Kwok Fai; Chan, Kwong Man [Princess Margaret Hospital, Department of Surgery (China); Ma, Johnny Ka Fai; Luk, Wing Hang [Princess Margaret Hospital, Department of Radiology (China); Chan, Micah Chi King [Princess Margaret Hospital, Department of Surgery (China); Ng, Carol Wing Kei; Mahboobani, Neeraj Ramesh [Princess Margaret Hospital, Department of Radiology (China); Ng, Wai Kin [Princess Margaret Hospital, Department of Surgery (China); Wong, Ting [Princess Margaret Hospital, Department of Radiology (China)

    2016-11-15

    Nellix Endovascular Aneurysm Sealing (EVAS) system is a new concept and technology of abdominal aortic aneurysm (AAA) repair. Elective EVAS using Nellix device was performed for a 83-year-old man with AAA. 2-month post-EVAS CTA surveillance demonstrated mild enlargement of aneurysmal sac and separation of the EndoBags, but without detectable endoleak. The patient developed sudden AAA rupture with retroperitoneal hematoma at about 4 months after EVAS. We postulated that early enlargement of aneurysmal sac and separation of EndoBags of Nellix devices after EVAS, even without detectable endoleak, might indicate significant aneurysmal wall weakening with increased risk of later AAA rupture. To the best of the authors’ knowledge, this was the first reported case of aortic rupture after EVAS without detectable endoleak during and after the procedure.

  10. Early Enlargement of Aneurysmal Sac and Separation of EndoBags of Nellix Endovascular Aneurysm Sealing System as Signs of Increased Risk of Later Aneurysm Rupture

    International Nuclear Information System (INIS)

    Cheng, Lik Fai; Cheung, Kwok Fai; Chan, Kwong Man; Ma, Johnny Ka Fai; Luk, Wing Hang; Chan, Micah Chi King; Ng, Carol Wing Kei; Mahboobani, Neeraj Ramesh; Ng, Wai Kin; Wong, Ting

    2016-01-01

    Nellix Endovascular Aneurysm Sealing (EVAS) system is a new concept and technology of abdominal aortic aneurysm (AAA) repair. Elective EVAS using Nellix device was performed for a 83-year-old man with AAA. 2-month post-EVAS CTA surveillance demonstrated mild enlargement of aneurysmal sac and separation of the EndoBags, but without detectable endoleak. The patient developed sudden AAA rupture with retroperitoneal hematoma at about 4 months after EVAS. We postulated that early enlargement of aneurysmal sac and separation of EndoBags of Nellix devices after EVAS, even without detectable endoleak, might indicate significant aneurysmal wall weakening with increased risk of later AAA rupture. To the best of the authors’ knowledge, this was the first reported case of aortic rupture after EVAS without detectable endoleak during and after the procedure.

  11. Interobserver variability in the assessment of aneurysm occlusion with the WEB aneurysm embolization system.

    Science.gov (United States)

    Fiorella, David; Arthur, Adam; Byrne, James; Pierot, Laurent; Molyneux, Andy; Duckwiler, Gary; McCarthy, Thomas; Strother, Charles

    2015-08-01

    The WEB (WEB aneurysm embolization system, Sequent Medical, Aliso Viejo, California, USA) is a self-expanding, nitinol, mesh device designed to achieve aneurysm occlusion after endosaccular deployment. The WEB Occlusion Scale (WOS) is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with intrasaccular mesh implants. This study was performed to assess the interobserver variability of the WOS. Seven experienced neurovascular specialists were trained to apply the WOS. These physicians independently reviewed angiographic image sets from 30 patients treated with the WEB under blinded conditions. No additional clinical information was provided. Raters graded each image according to the WOS (complete occlusion, residual neck or residual aneurysm). Final statistics were calculated using the dichotomous outcomes of complete occlusion or incomplete occlusion. The interobserver agreement was measured by the generalized κ statistic. In this series of 30 test case aneurysms, observers rated 12-17 as completely occluded, 3-9 as nearly completely occluded, and 9-11 as demonstrating residual aneurysm filling. Agreement was perfect across all seven observers for the presence or absence of complete occlusion in 22 of 30 cases. Overall, interobserver agreement was substantial (κ statistic 0.779 with a 95% CI of 0.700 to 0.857). The WOS allows a consistent means of reporting angiographic occlusion for aneurysms treated with the WEB device. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge; Grønbæk, Morten

    2013-01-01

    BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...... aneurysm in males and females consuming above 20g tobacco daily was 3.5% and 1.3%, among those >60years with plasma cholesterol >5mmol/L and a systolic blood pressure >140mmHg. CONCLUSIONS: Tobacco smoking is the most important predictor of future aortic aneurysm outcomes in the general population...

  13. Patient- and Aneurysm-Specific Risk Factors for Intracranial Aneurysm Growth : A Systematic Review and Meta-Analysis

    NARCIS (Netherlands)

    Backes, Daan; Rinkel, Gabriel J E; Laban, Kamil G.; Algra, Ale; Vergouwen, Mervyn D I

    2016-01-01

    BACKGROUND AND PURPOSE—: Follow-up imaging is often performed in intracranial aneurysms that are not treated. We performed a systematic review and meta-analysis on patient- and aneurysm-specific risk factors for aneurysm growth. METHODS—: We searched EMBASE and MEDLINE for cohort studies describing

  14. Retrospective analysis of the prevalence of asymptomatic cerebral aneurysm in 4518 patients undergoing magnetic resonance angiography. When does cerebral aneurysm develop?

    International Nuclear Information System (INIS)

    Horikoshi, Toru; Yamagata, Zentaro; Nukui, Hideaki; Akiyama, Iwao

    2002-01-01

    The natural history of cerebral aneurysms was investigated by measuring the prevalence of incidentally found unruptured aneurysms in the general population and evaluating the characteristics including risk factors. 'De novo' formation of aneurysm was also demographically estimated. The prevalence of incidental aneurysm was evaluated among 4518 patients who underwent magnetic resonance (MR) angiography for various reasons in a neurosurgical institute. Double the number of patients were randomly selected from the remaining patients without aneurysm as the Control group so that sex and age group were matched to the Aneurysm group. One hundred twenty seven patients (2.8%) had diagnoses of aneurysm. The prevalence of asymptomatic aneurysm among middle-aged and elderly patients were predominant in women and increased with age in both sexes. Patients with aneurysms had significantly more hypertension and family history of subarachnoid hemorrhage compared to the controls. The prevalence was markedly increased in the 8th decade in men and the 7th decade in women, and new aneurysms seemed to develop predominantly around these decades. Cerebral aneurysms become detectable on MR angiography in the middle or later decades, and women tend to develop aneurysm earlier than men. Hypertension and family history of subarachnoid hemorrhage are probably risk factors for the development of aneurysm. (author)

  15. Sensitive quench detection of the HTS coil using a co-winding coil

    International Nuclear Information System (INIS)

    Takagi, Tomohiro; Ariyama, Takahiro; Takao, Tomoaki; Tsukamoto, Osami

    2017-01-01

    The authors have studied the co-winding coil method (CW method) using the co-wound coil electrically insulated from the HTS coil. In this method, the quench is detected by the voltage difference between the coil of the HTS tape (HTS coil) and the coil of the normal conductor (CW coil). The voltage induced in the CW coil caused by the change of the magnetic field is almost the same as that in the HTS coil because the coils are magnetically coupled close to each other. Therefore, it is expected that the induced voltage will be canceled with high accuracy and that the resistive voltage in the HTS coil will be detected with greater sensitivity compared to the bridge balance method, which is used commonly. In this study, quench detection applying the CW method is demonstrated using an experimental double-pancake coil. A tape with the copper layer deposited on the polymer substrate was used as the insulated conductor wire to form the CW coil. An additional pancake coil was used to expose the experimental double-pancake coil to the external magnetic field asymmetrically. It was shown that the CW method can detect the resistive voltage with greater sensitivity even when the HTS coil was exposed to the changing asymmetric external magnetic field. (author)

  16. The role of inflammation in cerebral aneurysms

    Directory of Open Access Journals (Sweden)

    Ali H Turkmani

    2015-06-01

    Full Text Available The natural history of unruptured intracranial aneurysms (IAs is poorly understood. At present, risk factors for aneurysm rupture are limited to demographics and rudimentary anatomic features of the aneurysm. The first sign of aneurysm destabilization and rupture may be subarachnoid hemorrhage, a potentially devastating brain injury with high morbidity and mortality. An emerging body of literature suggests a complex inflammatory cascade likely promotes aneurysm wall remodeling and progressive ballooning of the arterial wall, ultimately terminating in aneurysm rupture. These events likely begin with hemodynamic, flow-related endothelial injury; the injured endothelium stimulates inflammation, including the recruitment and transmigration of inflammatory cells, particularly macrophages. Various proteases are secreted by the inflammatory infiltrate, resulting in degradation of the extracellular matrix and the structural changes unique to IAs. Detailed understanding of these inflammatory processes may result in (1 early identification of patients at high risk for aneurysm rupture, perhaps via arterial wall imaging, and (2 targeted, noninvasive therapies to treat or even prevent cerebral aneurysms.

  17. Ruptured gastroepiploic artery aneurysm: A case report

    Directory of Open Access Journals (Sweden)

    Ahmad S. Ashrafi

    Full Text Available Introduction: Gastroepiploic artery aneurysms are extremely rare, with few reported cases in the literature. The risk of rupture however, is high and thus warrants attention. Presentation of case: Here we present a rare case of a women who presented to the emergency department in shock and was found to have a ruptured gastroepiploic artery aneurysm during surgical exploration. Suture ligation of the aneurysm was completed. Discussion: Although rare, gastroepiploic artery aneurysms have up to a 90% rate of rupture and therefore require intervention. A laparoscopic approach has been described however, in cases where rupture has occurred, urgent laparotomy and control of hemorrhage is needed. Conclusion: We describe a rare case of a ruptured gastroepiploic aneurysm that was successfully managed with urgent laparotomy and aneurysmal resection. Keywords: Gastroepiploic, Aneurysm, Hemorrhage, Case report

  18. CFD for evaluation and treatment planning of aneurysms: review of proposed clinical uses and their challenges.

    Science.gov (United States)

    Chung, Bongjae; Cebral, Juan Raul

    2015-01-01

    Computational fluid dynamics (CFD) has been used for several years to identify mechanical risk factors associated with aneurysmal evolution and rupture as well as to understand flow characteristics before and after surgical treatments in order to help the clinical decision making process. We used the keywords, "CFD" and "aneurysms" to search recent publications since about 2000, and categorized them into (i) studies of rupture risk factors and (ii) investigations of pre- and post-evaluations of surgical treatment with devices like coils and flow diverters (FD). This search enables us to examine the current status of CFD as a clinical tool and to determine if CFD can potentially become an important part of the routine clinical practice for the evaluation and treatment of aneurysms in near future. According to previous reports, it has been argued that CFD has become a quite robust non-invasive tool for the evaluation of surgical devices, especially in the early stages of device design and it has also been applied successfully to the study of rupture risk assessment. However, we find that due to the large number of pre-processing inputs further efforts of validation and reproducibility of CFD with larger clinical datasets are still essential to identify standardized mechanical risk factors. As a result, we identify the following needs to have a robust CFD tool for clinical use: (i) more reliability tests through validation studies, (ii) analyses of larger generalized clinical datasets to find converging universal risk parameters, (iii) fluid structure interaction (FSI) analyses to better understand the detailed vascular remodeling processes associated with aneurysm growth, evolution and rupture, and (iv) better coordinated and organized communications and collaborations between engineers and clinicians.

  19. Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage.

    Science.gov (United States)

    Frölich, Andreas Maximilian; Nawka, Marie Teresa; Ernst, Marielle; Frischmuth, Isabell; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-01-01

    Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5-39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21-0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 --0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.

  20. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  1. Optimization of Coil Element Configurations for a Matrix Gradient Coil.

    Science.gov (United States)

    Kroboth, Stefan; Layton, Kelvin J; Jia, Feng; Littin, Sebastian; Yu, Huijun; Hennig, Jurgen; Zaitsev, Maxim

    2018-01-01

    Recently, matrix gradient coils (also termed multi-coils or multi-coil arrays) were introduced for imaging and B 0 shimming with 24, 48, and even 84 coil elements. However, in imaging applications, providing one amplifier per coil element is not always feasible due to high cost and technical complexity. In this simulation study, we show that an 84-channel matrix gradient coil (head insert for brain imaging) is able to create a wide variety of field shapes even if the number of amplifiers is reduced. An optimization algorithm was implemented that obtains groups of coil elements, such that a desired target field can be created by driving each group with an amplifier. This limits the number of amplifiers to the number of coil element groups. Simulated annealing is used due to the NP-hard combinatorial nature of the given problem. A spherical harmonic basis set up to the full third order within a sphere of 20-cm diameter in the center of the coil was investigated as target fields. We show that the median normalized least squares error for all target fields is below approximately 5% for 12 or more amplifiers. At the same time, the dissipated power stays within reasonable limits. With a relatively small set of amplifiers, switches can be used to sequentially generate spherical harmonics up to third order. The costs associated with a matrix gradient coil can be lowered, which increases the practical utility of matrix gradient coils.

  2. de novo'' aneurysms following endovascular procedures

    International Nuclear Information System (INIS)

    Briganti, F.; Cirillo, S.; Caranci, F.; Esposito, F.; Maiuri, F.

    2002-01-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  3. Appearance of femoropopliteal segment aneurysms in patients with abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Maksić Milanko

    2012-01-01

    Full Text Available Background/Aim. To promote better treatment outcome, as well as economic benefit it is very important to find out patients with simultaneous occurrence of both aortic and arterial aneurysms. The aim of this prospective study was to determine the frequency and factors affecting femoropopliteal (F-P segment aneurysms appearance in patients with abdominal aortic aneurysms (AAA. Methods. This study included 70 patients who had underwent elective or urgent surgery of AAA from January 1, 2006 to December 31, 2007. After ultrasonographic examination of F-P segment, all the patients were divided into two groups - those with adjunctive F-P segment aneurysm (n = 20 and the group of 50 patients with no adjunctive F-P segment aneurysm. In both groups demographic characteristics (gender, age, risk factors (diabetes mellitus, elevated serum levels of cholesterol and triglycerides, arterial hypertension, smoking, obesity and cardiovascular comorbidity (cerebrovascular desease, ischemic heart desease were investigated. Results. Twenty (28.57% patients who had been operated on because of AAA, had adjunctive aneurysmal desease of F-P segment. Diabetes was no statistically significantly more present among the patients who, beside AAA, had adjunctive aneurismal desease of F-P segment (χ2 = 0.04; DF = 1; p > 0.05. Also, in both groups there was no statistically significant difference in gender structure (χ2 = 2. 05; DF = 2; p > 0.05, age (χ2 = 5. 46; DF = 1; p > 0.05, total cholesterol level (χ2 = 0.89; DF = 1; p > 0.05 and triglyceride (χ2 = 0.89; DF = 1; p > 0.05 levels, the presence of arterial hypertension (χ2 = 1.38; DF = 2; p > 0.05, smoking (χ2 = 1.74; DF = 1; p > 0.05, obesity (χ2 = 1.76; DF = 1; p > 0.05 and presence of cerebrovascular desease (χ2 = 2.34; DF = 1; p > 0.05. Conversly, ischemic heart desease was statistically significantly more present among the patients who, beside AAA, had adjunctive aneurismal desease of F-P segment (χ2 = 5

  4. Development of a posterior cerebral artery aneurysm subsequent to occlusion of the contralateral internal carotid artery for giant cavernous aneurysm

    International Nuclear Information System (INIS)

    Wolf, R.L.; Hurst, R.W.; Imbesi, S.G.; Galetta, S.L.; Sinson, G.P.; Grossman, R.I.

    2002-01-01

    We report a case of a patient who developed a left posterior cerebral artery aneurysm 5 years after balloon occlusion of the right internal carotid artery for a giant cavernous aneurysm. The location of the new aneurysm was outside of the primary collateral pathways to the contralateral, proximally occluded, anterior circulation, illustrating the complexity of hemodynamic factors contributing to the development of intracranial saccular aneurysms. The appearance of an aneurysm in this setting supports the hypothesis that degenerative factors and hemodynamic stresses are important in the etiology of intracranial aneurysms. (orig.)

  5. Study on the related factors influencing the formation of intra-aneurysmal thrombosis in the established side-wall aneurysmal model in canine

    International Nuclear Information System (INIS)

    Zhou Bing; Li Minghua; Wang Jianbo; Zhu Yueqi; Yuan Jianhua; Yu Wenqiang

    2011-01-01

    Objective: To analyze the related factors influencing the formation of intra-aneurysmal thrombosis (IAT) in the established side-wall aneurysmal model in canine, and to discuss the measures to prevent the occurrence of IAT. Methods: Twenty canines were randomly divided into 4 groups for building side-wall aneurysmal model: group A, vertical aneurysm without use of postoperative anticoagulation medication; group B, vertical aneurysm with use of postoperative anticoagulation medication; group C, oblique aneurysm without use of postoperative anticoagulation medication; and group D, oblique aneurysm with use of postoperative anticoagulation medication. Angiography was performed to evaluate the IAT. The potential related factors influencing the formation of IAT, including sex, age, operative time, aneurysmal morphology, postoperative anticoagulation medication and cervical hematoma, were statistically analysed with emphasis on aneurysmal morphology and the use of postoperative anticoagulation medication. The statistical software SPSS 12.0 was employed. Results: A total of 40 aneurysms were successfully established in 20 canines. Cervical hematoma occurred in 7 canines and IAT developed in 8 aneurysms. The univariate analysis showed that the formation of IAT was significantly influenced by the aneurysmal morphology and cervical hematoma. Surprisingly, the formation of IAT bore no relation to the postoperative anticoagulation, whether the medication was employed or not, which was further confirmed by stratified analysis. Conclusion: To establish oblique aneurysm and to reduce the occurrence of cervical hematoma can effectively decrease the incidence of IAT in established side-wall aneurysmal model in canine. The postoperative anticoagulation medication can not decrease the incidence of IAT. (authors)

  6. Routine phasing of coiled-coil protein crystal structures with AMPLE

    Directory of Open Access Journals (Sweden)

    Jens M. H. Thomas

    2015-03-01

    Full Text Available Coiled-coil protein folds are among the most abundant in nature. These folds consist of long wound α-helices and are architecturally simple, but paradoxically their crystallographic structures are notoriously difficult to solve with molecular-replacement techniques. The program AMPLE can solve crystal structures by molecular replacement using ab initio search models in the absence of an existent homologous protein structure. AMPLE has been benchmarked on a large and diverse test set of coiled-coil crystal structures and has been found to solve 80% of all cases. Successes included structures with chain lengths of up to 253 residues and resolutions down to 2.9 Å, considerably extending the limits on size and resolution that are typically tractable by ab initio methodologies. The structures of two macromolecular complexes, one including DNA, were also successfully solved using their coiled-coil components. It is demonstrated that both the ab initio modelling and the use of ensemble search models contribute to the success of AMPLE by comparison with phasing attempts using single structures or ideal polyalanine helices. These successes suggest that molecular replacement with AMPLE should be the method of choice for the crystallographic elucidation of a coiled-coil structure. Furthermore, AMPLE may be able to exploit the presence of a coiled coil in a complex to provide a convenient route for phasing.

  7. Endovascular Exclusion of Renal Artery Aneurysm

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Rohr, Nils

    2005-01-01

    A patient who was operated for an abdominal aortic aneurysm 7 years earlier presented with recently discovered iliac and renal artery aneurysms. The renal artery had an angulation of 90 o , but the aneurysm was successfully excluded using a covered vascular stent graft placed over an extrastiff guidewire. Even in cases of complex anatomy of a renal aneurysm, endovascular treatment should be considered. With development of more flexible and low-profile endoprosthesis with accurate deployment, these have become more usable

  8. Treatment of a cervical carotid pseudoaneurysm that occurred years after laryngectomy and irradiation of a neck tumor. Case report

    International Nuclear Information System (INIS)

    Hanakita, Shunya; Iijima, Akira; Ishikawa, Osamu; Kamada, Kyousuke; Saito, Nobuhito

    2011-01-01

    A 62-year-old man presented with rupture of a pseudoaneurysm of the left common carotid artery (CCA) that was induced after radiation therapy and neck surgery. The initial treatment was an endovascular procedure to obliterate the aneurysm with coils, and a covered stent was placed in the parent artery. However, the patient presented with subsequent coil migration, wound infection, and left CCA stenosis. Direct surgical procedures were then performed, including resection of the pseudoaneurysm with coils and stent; replacement of the carotid artery with a saphenous vein graft; and operative wound reinforcement with a pedicle flap. Endovascular treatments may be chosen for vascular diseases after irradiation, because of the low risk of wound infection and fragility of the vessels, but the long-term outcomes of intravascular treatments are still unclear. In direct surgery, dissection of the adhesive tissue and adequate wound healing are difficult. Musculocutaneous flaps with vascular pedicles can achieve good results. (author)

  9. Giant serpentine intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Park, Jae Seong; Lee, Myeong Sub; Kim, Myung Soon; Kim, Dong Jin; Park, Joong Wha; Whang, Kum

    2001-01-01

    The authors present a case of giant serpentine aneurysm (a partially thrombosed aneurysm containing tortuous vascular channels with a separate entrance and outflow pathway). Giant serpentine aneurysms form a subgroup of giant intracranial aneurysms, distinct from saccular and fusiform varieties, and in this case, too, the clinical presentation and radiographic features of CT, MR imaging and angiography were distinct

  10. Triple Halo Coil: Development and Comparison with Other TMS Coils

    Science.gov (United States)

    Rastogi, Priyam; Hadimani, Ravi; Jiles, David

    Transcranial Magnetic Stimulation (TMS) is a non-invasive stimulation technique that can be used for the treatment of various neurological disorders such as Parkinson's Disease, PTSD, TBI and anxiety by regulating synaptic activity. TMS is FDA approved for the treatment of major depressive disorder. There is a critical need to develop deep TMS coils that can stimulate deeper regions of the brain without excessively stimulating the cortex in order to provide an alternative to surgical methods. We have developed a novel multi-coil configuration called ``Triple Halo Coil'' (THC) that can stimulate deep brain regions. Investigation of induced electric and magnetic field in these regions have been achieved by computer modelling. Comparison of the results due to THC configuration have been conducted with other TMS coils such as ``Halo Coil'', circular coil and ``Figure of Eight'' coil. There was an improvement of more than 15 times in the strength of magnetic field, induced by THC configuration at 10 cm below the vertex of the head when compared with the ``Figure of Eight'' coil alone. Carver Charitable Trust.

  11. Epidemiology and genetics of intracranial aneurysms

    International Nuclear Information System (INIS)

    Caranci, F.; Briganti, F.; Cirillo, L.; Leonardi, M.; Muto, M.

    2013-01-01

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  12. Epidemiology and genetics of intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Caranci, F., E-mail: ferdinandocaranci@libero.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Briganti, F., E-mail: frabriga@unina.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Cirillo, L.; Leonardi, M. [Neuroradiology service, Bellaria Hospital, Bologna (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service Cardarelli Hospital Naples (Italy)

    2013-10-01

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  13. Biomaterials Made from Coiled-Coil Peptides.

    Science.gov (United States)

    Conticello, Vincent; Hughes, Spencer; Modlin, Charles

    The development of biomaterials designed for specific applications is an important objective in personalized medicine. While the breadth and prominence of biomaterials have increased exponentially over the past decades, critical challenges remain to be addressed, particularly in the development of biomaterials that exhibit highly specific functions. These functional properties are often encoded within the molecular structure of the component molecules. Proteins, as a consequence of their structural specificity, represent useful substrates for the construction of functional biomaterials through rational design. This chapter provides an in-depth survey of biomaterials constructed from coiled-coils, one of the best-understood protein structural motifs. We discuss the utility of this structurally diverse and functionally tunable class of proteins for the creation of novel biomaterials. This discussion illustrates the progress that has been made in the development of coiled-coil biomaterials by showcasing studies that bridge the gap between the academic science and potential technological impact.

  14. [Congenital anomalies of cerebral artery and intracranial aneurysm].

    Science.gov (United States)

    Nakajima, K; Ito, Z; Hen, R; Uemura, K; Matsuoka, S

    1976-02-01

    It is well known that congenital anomalies such as polycystic kidney, aortic coarctation, Marfan syndrome, Ehler-Danlos syndrome are apt to be complicated by intracranial aneurysms. In this report we attempt to reveal the relation and incidence between cerebrovascular anomalies and intracranial aneurysms. The etiology of aneurysms has been discussed, too. 12 cases of persistent trigeminl artery, 2 cases of persistent hypoglossal artery and 11 cases of fenestration were obtained from 3841 patients who were angiographically examined in our clinic for 5 years. The incidence is 0.31%, 0.05% and 0.29%, respectively. Persistent trigeminal arteries were complicated by 2 cases of intracranial aneurysms and one case of arterivenous malformations (AVM), persistent hypoglossal arteries were complicated by one case of aneurysm, and fenestrations were complicated by 2 cases of aneurysms and one case of AVM. One case of congenital agenesis of right internal carotid artery was obtained which was complicated by aneurysm of anterior communicating artery. Totally, 8 cases of aneurysms and AVM were obtained from 26 cases of cerebrovascular anomalies (incidence 30.8%). On the other hand, thalamic or caudate hemorrhage revealed the highest incidence of complication of intracranial aneurysms among intracerebral hematomas (10.7%). Compared with the incidence of aneurysms between cerebro vascular anomalies (30.8%) and thalamic or caudate hemorrhage (10.7%), the difference is statistically signigicant (P less than 0.05). The cause of intracranial aneurysm has not yet been clarified. But it is well accepted that the defect of tunica media vasorum is most responsible factor as to the occurrence of intracranial aneurysms. We concluded that the genetic error of cerebral vessels including defect of media caused intracranial aneurysms, and this result was supported from the evidence that cerebrovascular anomalies showed statistically high incidence of complication of intracranial aneurysms.

  15. Mycotic Aneurysm of the Aortic Arch

    Directory of Open Access Journals (Sweden)

    Ji Hye Seo

    2014-08-01

    Full Text Available A mycotic aneurysm of the thoracic aorta is rare. We report a case of mycotic aneurysm that developed in the aortic arch. An 86-year-old man was admitted with fever and general weakness. Blood culture yielded methicillin-resistant Staphylococcus aureus. Chest X-ray showed an enlarged aortic arch, and computed tomography scan revealed an aneurysm in the aortic arch. The patient was treated only with antibiotics and not surgically. The size of the aneurysm increased rapidly, resulting in bronchial obstruction and superimposed pneumonia. The patient died of respiratory failure.

  16. Isolated iliac artery aneurysms with associated hydronephrosis.

    LENUS (Irish Health Repository)

    O'Driscoll, D

    2012-02-03

    An isolated iliac artery aneurysm is where there is aneurysmal dilatation of one or more branches of the iliac system, with no associated dilatation of the aorta. Such aneurysms are rare and comprise 1% of all intra-abdominal aneurysms. The signs and symptoms of such an aneurysm are influenced by its concealed location within the bony pelvis. Awareness of these special characteristics improves the chances of early diagnosis and proper treatment before possible rupture. We present the clinical and radiological features of three such aneurysms. Ultrasound was the first imaging modality to be performed. Ipsilateral hydronephrosis was demonstrated in each case, this lead to imaging the pelvis and the correct diagnosis. We review the clinical and radiological literature and conclude that the pelvis should be imaged in all cases of unexplained hydronephrosis.

  17. An anatomic risk model to screen post endovascular aneurysm repair patients for aneurysm sac enlargement.

    Science.gov (United States)

    Png, Chien Yi M; Tadros, Rami O; Beckerman, William E; Han, Daniel K; Tardiff, Melissa L; Torres, Marielle R; Marin, Michael L; Faries, Peter L

    2017-09-01

    Follow-up computed tomography angiography (CTA) scans add considerable postimplantation costs to endovascular aneurysm repairs (EVARs) of abdominal aortic aneurysms (AAAs). By building a risk model, we hope to identify patients at low risk for aneurysm sac enlargement to minimize unnecessary CTAs. 895 consecutive patients who underwent EVAR for AAA were reviewed, of which 556 met inclusion criteria. A Probit model was created for aneurysm sac enlargement, with preoperative aneurysm morphology, patient demographics, and operative details as variables. Our final model included 287 patients and had a sensitivity of 100%, a specificity of 68.9%, and an accuracy of 70.4%. Ninety-nine (35%) of patients were assigned to the high-risk group, whereas 188 (65%) of patients were assigned to the low-risk group. Notably, regarding anatomic variables, our model reported that age, pulmonary comorbidities, aortic neck diameter, iliac artery length, and aneurysms were independent predictors of post-EVAR sac enlargement. With the exception of age, all statistically significant variables were qualitatively supported by prior literature. With regards to secondary outcomes, the high-risk group had significantly higher proportions of AAA-related deaths (5.1% versus 1.1%, P = 0.037) and Type 1 endoleaks (9.1% versus 3.2%, P = 0.033). Our model is a decent predictor of patients at low risk for post AAA EVAR aneurysm sac enlargement and associated complications. With additional validation and refinement, it could be applied to practices to cut down on the overall need for postimplantation CTA. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Familial Abdominal Aortic Aneurysm : Clinical Features and Genetics

    NARCIS (Netherlands)

    K.M. van de Luijtgaarden (Koen)

    2016-01-01

    markdownabstractAbstract Cardiovascular disease is the most important cause of death in the world and encompasses occlusive as well as aneurysmal disease. The most common aneurysm in humans is the abdominal aortic aneurysm (AAA). The question is why the aorta dilates in aneurysmal disease and

  19. Traumatic aneurysms of the pericallosal arteries

    International Nuclear Information System (INIS)

    Nakstad, P.; Nornes, H.; Hauge, H.N.

    1986-01-01

    Of a total of 912 operated intracranial aneurysms only three were classified as traumatic (0.3%). They were found in children after severe head trauma and were all located on the pericallosal artery or its branches and not a bifurcations. Shearing forces between the falx, the arteries and the brain at the time of injury are held responsible for the development of these aneurysms. Unlike these traumatic aneurysms, 29 ''spontaneous'' pericallosal aneurysms (3.2%) in adults were located at the bifurcations of the artery. As significantly fewer reports of traumatic aneurysms have been published during the last decade than before 1976, it is suggested that some might have been overlooked as a consequence of CT replacing cerebral angiography in the neuroradiological evaluation of severe head injury. This possibility should be kept in mind, especially when dealing with children after head injury and when CT scans indicate brain damage around the falx. The possibility of overlooking traumatic pericallosal aneurysms is described by other authors and discussed further in this paper. (orig.)

  20. Bilateral giant femoropopliteal artery aneurysms: a case report

    Directory of Open Access Journals (Sweden)

    Perdikides Theodossios P

    2008-04-01

    Full Text Available Abstract Introduction Popliteal artery aneurysms are the most common peripheral arterial aneurysms, and are frequently bilateral. Acute limb ischemia, rupture and compression phenomena can complicate these aneurysms when the diameter exceeds 2 cm. Case Presentation We report an 82-year-old male patient with two giant femoropopliteal aneurysms, 10.5 and 8.5 cm diameters, managed in our institution. Both aneurysms were resected and a polytetrafluoroethylene (PTFE femoropopliteal interposition graft was placed successfully. Management and literature review are discussed. Conclusion We believe this is the first report in the medical literature of bilateral giant femoropopliteal aneurysms.

  1. The risk of endoleak following stent covering of the internal iliac artery during endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Rajesparan, K.; Partridge, W.; Refson, J.; Abidia, A.; Aldin, Z.

    2014-01-01

    Aim: To investigate the risk of endoleak during endovascular aneurysm repair (EVAR) involving the distal common iliac artery (CIA) when the internal iliac artery (IIA) is covered without prior coil embolization. Materials and methods: Retrospective analysis of 145 (125 men, 20 women) consecutive EVAR cases. Clinical notes and radiological images were reviewed, and data collected on patient demographics, aneurysm morphology, covering of the IIA with or without embolization, presence of endoleaks, and patient symptoms relating to IIA ischaemia. Results: A total of 29 IIAs (10%) were covered in a total of 25 patients. Seven IIAs (24%) were embolized before stent covering (Embolization group), and 22 IIAs (76%) were covered only without embolization (Cover group). There was no statistically significant difference in the mean size of the abdominal aortic aneurysm diameter or CIA diameter between each group. No endoleaks from IIA retrograde filling were found in either group. Conclusion: The results of the present study do not support the traditional view that coverage of the IIA without prior embolization carries a high risk of endoleak, with no endoleaks seen in all 22 cases. Large-scale trials are required. However, the advent of branched-stenting techniques and the emergence of their success in long-term follow-up may preclude the former. - Highlights: • No EVAR endoleaks due to retrograde filling of the internal iliac artery (IIA). • No increased risk of endoleak with stent coverage of the IIA without embolisation. • Current evidence does not support traditional views

  2. Development of a new error field correction coil (C-coil) for DIII-D

    International Nuclear Information System (INIS)

    Robinson, J.I.; Scoville, J.T.

    1995-12-01

    The C-coil recently installed on the DIII-D tokamak was developed to reduce the error fields created by imperfections in the location and geometry of the existing coils used to confine, heat, and shape the plasma. First results from C-coil experiments include stable operation in a 1.6 MA plasma with a density less than 1.0 x 10 13 cm -3 , nearly a factor of three lower density than that achievable without the C-coil. The C-coil has also been used in magnetic braking of the plasma rotation and high energy particle confinement experiments. The C-coil system consists of six individual saddle coils, each 60 degree wide toroidally, spanning the midplane of the vessel with a vertical height of 1.6 m. The coils are located at a major radius of 3.2 m, just outside of the toroidal field coils. The actual shape and geometry of each coil section varied somewhat from the nominal dimensions due to the large number of obstructions to the desired coil path around the already crowded tokamak. Each coil section consists of four turns of 750 MCM insulated copper cable banded with stainless steel straps within the web of a 3 in. x 3 in. stainless steel angle frame. The C-coil structure was designed to resist peak transient radial forces (up to 1,800 Nm) exerted on the coil by the toroidal and ploidal fields. The coil frames were supported from existing poloidal field coil case brackets, coil studs, and various other structures on the tokamak

  3. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  4. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  5. Extra-anatomic endovascular repair of an abdominal aortic aneurysm with a horseshoe kidney supplied by the aneurysmal aorta.

    Science.gov (United States)

    Rey, Jorge; Golpanian, Samuel; Yang, Jane K; Moreno, Enrique; Velazquez, Omaida C; Goldstein, Lee J; Chahwala, Veer

    2015-07-01

    Abdominal aortic aneurysm complicated by a horseshoe kidney (HSK, fused kidney) represents a unique challenge for repair. Renal arteries arising from the aneurysmal aorta can further complicate intervention. Reports exist describing the repair of these complex anatomies using fenestrated endografts, hybrid open repairs (debranching), and open aneurysmorrhaphy with preservation of renal circulation. We describe an extra-anatomic, fully endovascular repair of an abdominal aortic aneurysm with a HSK partially supplied by a renal artery arising from the aneurysm. We successfully applied aortouni-iliac endografting, femorofemoral bypass, and retrograde renal artery perfusion via the contralateral femoral artery to exclude the abdominal aortic aneurysm and preserve circulation to the HSK. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Conformational switching in the coiled-coil domains of a proteasomal ATPase regulates substrate processing.

    Science.gov (United States)

    Snoberger, Aaron; Brettrager, Evan J; Smith, David M

    2018-06-18

    Protein degradation in all domains of life requires ATPases that unfold and inject proteins into compartmentalized proteolytic chambers. Proteasomal ATPases in eukaryotes and archaea contain poorly understood N-terminally conserved coiled-coil domains. In this study, we engineer disulfide crosslinks in the coiled-coils of the archaeal proteasomal ATPase (PAN) and report that its three identical coiled-coil domains can adopt three different conformations: (1) in-register and zipped, (2) in-register and partially unzipped, and (3) out-of-register. This conformational heterogeneity conflicts with PAN's symmetrical OB-coiled-coil crystal structure but resembles the conformational heterogeneity of the 26S proteasomal ATPases' coiled-coils. Furthermore, we find that one coiled-coil can be conformationally constrained even while unfolding substrates, and conformational changes in two of the coiled-coils regulate PAN switching between resting and active states. This switching functionally mimics similar states proposed for the 26S proteasome from cryo-EM. These findings thus build a mechanistic framework to understand regulation of proteasome activity.

  7. Design of the coolant system for the Large Coil Test Facility pulse coils

    International Nuclear Information System (INIS)

    Bridgman, C.; Ryan, T.L.

    1983-01-01

    The pulse coils will be a part of the Large Coil Test Facility in Oak Ridge, Tennessee, which is designed to test six large tokamak-type superconducting coils. The pulse coil set consists of two resistive coaxial solenoid coils, mounted so that their magnetic axis is perpendicular to the toroidal field lines of the test coil. The pulse coils provide transient vertical fields at test coil locations to simulate the pulsed vertical fields present in tokamak devices. The pulse coils are designed to be pulsed for 30 s every 150 s, which results in a Joule heating of 116 kW per coil. In order to provide this capability, the pulse coil coolant system is required to deliver 6.3 L/s (100 gpm) of subcooled liquid nitrogen at 10-atm absolute pressure. The coolant system can also cool down each pulse coil from room temperature to liquid nitrogen temperature. This paper provides details of the pumping and heat exchange equipment designed for the coolant system and of the associated instrumentation and controls

  8. Advances in the imaging of cerebral aneurysm inflammation

    Directory of Open Access Journals (Sweden)

    Michael R Levitt

    2015-06-01

    Full Text Available Cerebral aneurysm formation, growth and rupture are thought to be the result of a complex interaction between cerebrovascular hemodynamics and pathobiology. Recently, new evidence has emerged regarding the role of inflammation in the walls of cerebral aneurysms. Noninvasive methods to characterize the degree of inflammation in aneurysms could enable clinicians to estimate the risk of future aneurysm growth and rupture, influencing treatment. This review examines emerging techniques of imaging inflammatory biomarkers in cerebral aneurysms.

  9. Carotid artery aneurysm resulting in myxedema coma

    Directory of Open Access Journals (Sweden)

    Elizabeth M. Lamos

    2015-06-01

    Full Text Available Intra-sellar aneurysms are a rare, but important consideration when evaluating pituitary masses. Identification of aneurysms is critical to appropriate treatment and avoiding perilous consequences. These vascular aneurysms can result in severe endocrine dysfunction due to mass effect, stripping of the vascular supply to the pituitary, or hemorrhage. Here we describe a novel case of spontaneous myxedema coma and pituitary apoplexy secondary to a large internal carotid artery aneurysm.

  10. Measurement of heating coil temperature for e-cigarettes with a "top-coil" clearomizer.

    Science.gov (United States)

    Chen, Wenhao; Wang, Ping; Ito, Kazuhide; Fowles, Jeff; Shusterman, Dennis; Jaques, Peter A; Kumagai, Kazukiyo

    2018-01-01

    To determine the effect of applied power settings, coil wetness conditions, and e-liquid compositions on the coil heating temperature for e-cigarettes with a "top-coil" clearomizer, and to make associations of coil conditions with emission of toxic carbonyl compounds by combining results herein with the literature. The coil temperature of a second generation e-cigarette was measured at various applied power levels, coil conditions, and e-liquid compositions, including (1) measurements by thermocouple at three e-liquid fill levels (dry, wet-through-wick, and full-wet), three coil resistances (low, standard, and high), and four voltage settings (3-6 V) for multiple coils using propylene glycol (PG) as a test liquid; (2) measurements by thermocouple at additional degrees of coil wetness for a high resistance coil using PG; and (3) measurements by both thermocouple and infrared (IR) camera for high resistance coils using PG alone and a 1:1 (wt/wt) mixture of PG and glycerol (PG/GL). For single point thermocouple measurements with PG, coil temperatures ranged from 322 ‒ 1008°C, 145 ‒ 334°C, and 110 ‒ 185°C under dry, wet-through-wick, and full-wet conditions, respectively, for the total of 13 replaceable coil heads. For conditions measured with both a thermocouple and an IR camera, all thermocouple measurements were between the minimum and maximum across-coil IR camera measurements and equal to 74% ‒ 115% of the across-coil mean, depending on test conditions. The IR camera showed details of the non-uniform temperature distribution across heating coils. The large temperature variations under wet-through-wick conditions may explain the large variations in formaldehyde formation rate reported in the literature for such "top-coil" clearomizers. This study established a simple and straight-forward protocol to systematically measure e-cigarette coil heating temperature under dry, wet-through-wick, and full-wet conditions. In addition to applied power, the

  11. The pretzel sign: angiographic pattern of tortuous intra-aneurysmal blood flow in a giant serpentine aneurysm.

    LENUS (Irish Health Repository)

    Fanning, N F

    2012-02-03

    Giant serpentine aneurysms (GSAs) form a specific subgroup of giant cerebral aneurysms that have pathognomonic angiographic features. We report the angiographic findings of a GSA demonstrating a striking convoluted dynamic flow pattern, which we have called the \\'pretzel sign\\'. The aneurysm was successfully treated by permanent occlusion of the parent vessel using a detachable balloon. GSAs should be identified prior to treatment in view of their particular management requirements.

  12. Superconducting magnetic coil

    Science.gov (United States)

    Aized, Dawood; Schwall, Robert E.

    1996-06-11

    A superconducting magnetic coil includes a plurality of sections positioned axially along the longitudinal axis of the coil, each section being formed of an anisotropic high temperature superconductor material wound about a longitudinal axis of the coil and having an associated critical current value that is dependent on the orientation of the magnetic field of the coil. The cross section of the superconductor, or the type of superconductor material, at sections along the axial and radial axes of the coil are changed to provide an increased critical current at those regions where the magnetic field is oriented more perpendicularly to the conductor plane, to thereby increase the critical current at these regions and to maintain an overall higher critical current of the coil.

  13. The pathogenesis shared between abdominal aortic aneurysms and intracranial aneurysms: a microarray analysis.

    Science.gov (United States)

    Wang, Wen; Li, Hao; Zhao, Zheng; Wang, Haoyuan; Zhang, Dong; Zhang, Yan; Lan, Qing; Wang, Jiangfei; Cao, Yong; Zhao, Jizong

    2018-04-01

    Abdominal aortic aneurysms (AAAs) and intracranial saccular aneurysms (IAs) are the most common types of aneurysms. This study was to investigate the common pathogenesis shared between these two kinds of aneurysms. We collected 12 IAs samples and 12 control arteries from the Beijing Tiantan Hospital and performed microarray analysis. In addition, we utilized the microarray datasets of IAs and AAAs from the Gene Expression Omnibus (GEO), in combination with our microarray results, to generate messenger RNA expression profiles for both AAAs and IAs in our study. Functional exploration and protein-protein interaction (PPI) analysis were performed. A total of 727 common genes were differentially expressed (404 was upregulated; 323 was downregulated) for both AAAs and IAs. The GO and pathway analyses showed that the common dysregulated genes were mainly enriched in vascular smooth muscle contraction, muscle contraction, immune response, defense response, cell activation, IL-6 signaling and chemokine signaling pathways, etc. The further protein-protein analysis identified 35 hub nodes, including TNF, IL6, MAPK13, and CCL5. These hub node genes were enriched in inflammatory response, positive regulation of IL-6 production, chemokine signaling pathway, and T/B cell receptor signaling pathway. Our study will gain new insight into the molecular mechanisms for the pathogenesis of both types of aneurysms and provide new therapeutic targets for the patients harboring AAAs and IAs.

  14. Magnetic resonance dacryocystography: comparison between conventional surface coils and microscopic coils

    International Nuclear Information System (INIS)

    Abreu Junior, Luiz de; Wolosker, Angela Maria Borri; Borri, Maria Lucia; Galvao Filho, Mario de Melo; Hartmann, Luiz Guilherme de Carvalho; D'Ippolito, Giuseppe; Castro, Claudio Campi de

    2008-01-01

    Objective: Magnetic resonance imaging has been utilized in the evaluation of the lacrimal apparatus with some advantages over conventional dacryocystography. The present study was aimed at acquiring high resolution images utilizing microscopic coils for evaluating typical structures of the lacrimal apparatus as compared with the findings observed with conventional surface coils. Materials and methods: Five asymptomatic volunteers with no history of epiphora were submitted to high-field magnetic resonance imaging with microscopic and conventional surface coils, and STIR sequence after instillation of saline solution. The definition of normal anatomic structures of lacrimal apparatuses was compared utilizing conventional and microscopic surface coils. Based on a consensual scoring system, the mean values for each structure were calculated by two observers. Results: In 90% of cases, higher scores were attributed to images acquired with the microscopic coil. On average, a 1.17 point increase was observed in the scoring of anatomic structures imaged with the microscopic coil. Additionally, a subjective improvement was observed in the signal-to-noise ratio with the microscopic coil. Conclusion: Magnetic resonance dacryocystography with microscopic coils is the appropriate method for evaluating the lacrimal apparatus, providing images with better quality as compared with those acquired with conventional surface coils. (author)

  15. Hemodynamic transition driven by stent porosity in sidewall aneurysms.

    Science.gov (United States)

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2015-05-01

    The healing process of intracranial aneurysms (IAs) treated with flow diverter stents (FDSs) depends on the IA flow modifications and on the epithelization process over the neck. In sidewall IA models with straight parent artery, two main hemodynamic regimes with different flow patterns and IA flow magnitude were broadly observed for unstented and high porosity stented IA on one side, and low porosity stented IA on the other side. The hemodynamic transition between these two regimes is potentially involved in thrombosis formation. In the present study, CFD simulations and multi-time lag (MTL) particle imaging velocimetry (PIV) measurements were combined to investigate the physical nature of this transition. Measurable velocity fields and non-measurable shear stress and pressure fields were assessed experimentally and numerically in the aneurysm volume in the presence of stents with various porosities. The two main regimes observed in both PIV and CFD showed typical flow features of shear and pressure driven regimes. In particular, the waveform of the averaged IA velocities was matching both the shear stress waveform at IA neck or the pressure gradient waveform in parent artery. Moreover, the transition between the two regimes was controlled by stent porosity: a decrease of stent porosity leads to an increase (decrease) of pressure differential (shear stress) through IA neck. Finally, a good PIV-CFD agreement was found except in transitional regimes and low motion eddies due to small mismatch of PIV-CFD running conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  17. Compact stellarator coils

    International Nuclear Information System (INIS)

    Pomphrey, N.; Berry, L.A.; Boozer, A.H.

    2001-01-01

    Experimental devices to study the physics of high-beta (β>∼4%), low aspect ratio (A<∼4.5) stellarator plasmas require coils that will produce plasmas satisfying a set of physics goals, provide experimental flexibility, and be practical to construct. In the course of designing a flexible coil set for the National Compact Stellarator Experiment, we have made several innovations that may be useful in future stellarator design efforts. These include: the use of Singular Value Decomposition methods for obtaining families of smooth current potentials on distant coil winding surfaces from which low current density solutions may be identified; the use of a Control Matrix Method for identifying which few of the many detailed elements of the stellarator boundary must be targeted if a coil set is to provide fields to control the essential physics of the plasma; the use of Genetic Algorithms for choosing an optimal set of discrete coils from a continuum of potential contours; the evaluation of alternate coil topologies for balancing the tradeoff between physics objective and engineering constraints; the development of a new coil optimization code for designing modular coils, and the identification of a 'natural' basis for describing current sheet distributions. (author)

  18. Findings of the International Subarachnoid Aneurysm Trial and the National Study of Subarachnoid Haemorrhage in context.

    Science.gov (United States)

    Reeves, B C; Langham, J; Lindsay, K W; Molyneux, A J; Browne, J P; Copley, L; Shaw, D; Gholkar, A; Kirkpatrick, P J

    2007-08-01

    Concern has been expressed about the applicability of the findings of the International Subarachnoid Aneurysm Trial (ISAT) with respect to the relative effects on outcome of coiling and clipping. It has been suggested that the findings of the National Study of Subarachnoid Haemorrhage may have greater relevance for neurosurgical practice. The objective of this paper was to interpret the findings of these two studies in the context of differences in their study populations, design, execution and analysis. Because of differences in design and analysis, the findings of the two studies are not directly comparable. The ISAT analysed all randomized patients by intention-to-treat, including some who did not undergo a repair, and obtained the primary outcome for 99% of participants. The National Study only analysed participants who underwent clipping or coiling, according to the method of repair, and obtained the primary outcome for 91% of participants. Time to repair was also considered differently in the two studies. The comparison between coiling and clipping was susceptible to confounding in the National Study, but not in the ISAT. The two study populations differed to some extent, but inspection of these differences does not support the view that coiling was applied inappropriately in the National Study. Therefore, there are many reasons why the two studies estimated different sizes of effect. The possibility that there were real, systematic differences in practice between the ISAT and the National Study cannot be ruled out, but such explanations must be seen in the context of other explanations relating to chance, differences in design or analysis, or confounding.

  19. Idiopathic subvalvular aortic aneurysm masquerading as acute coronary syndrome.

    Science.gov (United States)

    Natarajan, Balaji; Ramanathan, Sundar; Subramaniam, Natarajan; Janardhanan, Rajesh

    2016-09-02

    Subvalvular aneurysms are the least common type of left ventricular (LV) aneurysms and can be fatal. Subaortic LV aneurysms are much rarer than submitral LV aneurysms and mostly reported in infancy. They can be congenital or acquired secondary to infections, cardiac surgery or trauma. Here, we report a unique presentation of a large, idiopathic subaortic aneurysm in an adult masquerading as an acute coronary syndrome. Diagnosis was made with the help of a CT aortography. Aneurysm was surgically resected with good results. This case highlights the clinical presentation and management of subaortic aneurysms, an important differential for congenital aortic malformations. 2016 BMJ Publishing Group Ltd.

  20. Extracranial internal carotid artery aneurysm: case illustration

    Directory of Open Access Journals (Sweden)

    Zenteno Marco

    2017-12-01

    Full Text Available Extracranial internal carotid artery aneurysms (EICAA are uncommon lesion. These aneurysms can be classified as true or false aneurysms, atherosclerotic, dysplastic, infectious, posttraumatic and iatrogenic aneurysms. The most common presentation is central neurologic dysfunction, either a stroke or a transient ischemic attack. The rupture of these aneurysms can lead to severely impairment and can affect the quality of life of the patients or even may lead to death. Management of these lesions is required in most cases to prevent complications, however there is no treatment guideline or expert consensus for the management. We present a case of an unusual EICAA, associated with kinking of the affected vessel and review the literature.

  1. Plasmodium vivax antigen discovery based on alpha-helical coiled coil protein motif

    DEFF Research Database (Denmark)

    Céspedes, Nora; Habel, Catherine; Lopez-Perez, Mary

    2014-01-01

    Protein α-helical coiled coil structures that elicit antibody responses, which block critical functions of medically important microorganisms, represent a means for vaccine development. By using bioinformatics algorithms, a total of 50 antigens with α-helical coiled coil motifs orthologous to Pla...

  2. NCSX Trim Coil Design

    International Nuclear Information System (INIS)

    Kalish, M.; Brooks, A.; Rushinski, J.; Upcavage, R.

    2009-01-01

    The National Compact Stellarator Experiment (NCSX) was being constructed at the Princeton Plasma Physics Laboratory in partnership with Oak Ridge National Laboratory before work was stopped in 2008. The objective of this experiment was to develop the stellarator concept and evaluate it's potential as a model for future fusion power plants. Stellarator design requires very precisely positioned Modular Coils of complex shape to form 3D plasmas. In the design of NCSX, Trim Coils were required to compensate for both the positioning of the coils during assembly and the fabrication tolerances of the Modular Coils. Use of the Trim Coils allowed for larger tolerances increasing ease of assembly and decreasing overall cost. A set of Trim coils was developed to suppress the toroidal flux in island regions due to misalignment, magnetic materials, and eddy currents. The requirement imposed upon the design forced the toroidal flux in island regions below 10% of the total toroidal flux in the plasma. An analysis was first performed to evaluate candidate Trim Coil configurations iterating both the size, number, and position of the coils. The design was optimized considering both performance and cost while staying within the tight restraints presented by the space limited geometry. The final design of the Trim Coils incorporated a 48 Coil top bottom symmetric set. Fabrication costs were minimized by having only two coil types and using a planar conventional design with off the shelf commercial conductor. The Trim Coil design incorporated supports made from simple structural shapes assembled together in a way which allowed for adjustment as well as accommodation for the tolerance build up on the mating surfaces. This paper will summarize the analysis that led to the optimization of the Trim Coils set, the trim coil mechanical design, thermal and stress analysis, and the design of the supporting Trim Coil structure

  3. Hemodynamics Modeling and Simulation of Anterior Communicating Artery Aneurysms

    Directory of Open Access Journals (Sweden)

    Jianjun Li

    2014-07-01

    Full Text Available It is a general agreement that hemodynamics plays very important role in the initiation, growth, and rupture of cerebral aneurysms and hemodynamics in the anterior communicating artery aneurysms is considered the most complex in all cerebral aneurysms and it is difficult to find some reasonable relationship between the hemodynamics parameters and the rupture risk. In this paper, the 3D geometries of four anterior communicating artery aneurysms were generated from the CTA data and the computational models with bilateral feeding arteries for the four aneurysms were constructed. The blood flow was simulated by computational fluid dynamics software and the hemodynamics parameters such as velocity, wall shear stress, and oscillatory shear index were calculated. The following results were observed: one of the four models only needs the left feeding artery; the max normalized wall shear stress locates at the aneurysmal neck of the largest aneurysm; the max oscillatory shear index locates at the aneurysmal sac of the largest aneurysm. The conclusion was drawn that the anterior communicating artery aneurysm has higher rupture risk from the hemodynamics viewpoint if the max wall shear stress locates at the neck and the max oscillatory shear index locates at the dome.

  4. Composite coils for toroidal field coils and method of using same

    International Nuclear Information System (INIS)

    Perkins, R. G.; Trujillo, S. M.

    1985-01-01

    A composite toroidal field (TF) generating means consisting of segmented magnetic coil windings is disclosed. Each coil winding of the TF generating means consists of a copper or copper alloy conductor segment and an aluminum or aluminum alloy conductor segment. The conductor segments are joined at a high strength, low electrical resistance joint and the joint may either be a mechanical or metallurgical one. The use of the aluminum or aluminum alloy conductor segments improves the neutron economy of the reactor with which the TF coil is associated and reduces TF coil nuclear heating and heating gradients, and activation in the TF coils

  5. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    NARCIS (Netherlands)

    F.M.V. Bastos Gonçalves (Frederico); H.J.M. Verhagen (Hence); K. Chinsakchai (Khamin); J.W. van Keulen (Jasper); M.T. Voûte (Michiel); H.J.A. Zandvoort (Herman); F.L. Moll (Frans); J.A. van Herwaarden (Joost)

    2012-01-01

    textabstractObjective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The

  6. Recurrence of ICA-PCoA aneurysms after neck clipping.

    Science.gov (United States)

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  7. The Effect of Hemodynamics on Cerebral Aneurysm Morphology

    Science.gov (United States)

    Metcalfe, Ralph; Mantha, Aishwarya; Karmonik, Christof; Strother, Charles

    2004-11-01

    One of the difficulties in applying principles of hemodynamics to the study of blood flow in aneurysms are the drastic variations in possible shape of both the aneurysms and the parent arteries in the region of interest. We have taken data from three para-opthalmic internal carotid artery aneurysms using 3D-digital subtraction angiography (3D-DSA) and performed CFD simulations of steady and unsteady flows through the three different cases using the same pressure gradients and pulsatile flow waveforms (based on the Ku model for flow through the Carotid bifurcation). We have found that the total pressure differential within the aneurysms is consistent with the direction of flow, and that the dynamic pressure gradient within the aneurysm is very small compared with the static pressure variations. Wall shear stresses were highest near regions of sharp arterial curvature, but always remained low inside the aneurysm. These results suggest a more complex role for hemodynamics in aneurysm generation, growth and rupture.

  8. Outcomes with single-coil versus dual-coil implantable cardioverter defibrillators: a meta-analysis.

    Science.gov (United States)

    Sunderland, Nicholas; Kaura, Amit; Murgatroyd, Francis; Dhillon, Para; Scott, Paul A

    2018-03-01

    Dual-coil implantable cardioverter defibrillator (ICD) leads have traditionally been used over single-coil leads due to concerns regarding high defibrillation thresholds (DFT) and consequent poor shock efficacy. However, accumulating evidence suggests that this position may be unfounded and that dual-coil leads may also be associated with higher complication rates during lead extraction. This meta-analysis collates data comparing dual- and single-coil ICD leads. Electronic databases were systematically searched for randomized controlled trials (RCT) and non-randomized studies comparing single-coil and dual-coil leads. The mean differences in DFT and summary estimates of the odds-ratio (OR) for first-shock efficacy and the hazard-ratio (HR) for all-cause mortality were calculated using random effects models. Eighteen studies including a total of 138,124 patients were identified. Dual-coil leads were associated with a lower DFT compared to single coil leads (mean difference -0.83J; 95% confidence interval [CI] -1.39--0.27; P = 0.004). There was no difference in the first-shock success rate with dual-coil compared to single-coil leads (OR 0.74; 95%CI 0.45-1.21; P=0.22). There was a significantly lower risk of all-cause mortality associated with single-coil leads (HR 0.91; 95%CI 0.86-0.95; P dual-coil leads. The mortality benefit with single-coil leads most likely represents patient selection bias. Given the increased risk and complexity of extracting dual-coil leads, centres should strongly consider single-coil ICD leads as the lead of choice for routine new left-sided ICD implants. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  9. Morphological and clinical risk factors for posterior communicating artery aneurysm rupture.

    Science.gov (United States)

    Matsukawa, Hidetoshi; Fujii, Motoharu; Akaike, Gensuke; Uemura, Akihiro; Takahashi, Osamu; Niimi, Yasunari; Shinoda, Masaki

    2014-01-01

    Recent studies have shown that posterior circulation aneurysms, specifically posterior communicating artery (PCoA) aneurysms, are more likely to rupture than other aneurysms. To date, few studies have investigated the factors contributing to PCoA aneurysm rupture. The authors aimed to identify morphological and clinical characteristics predisposing to PCoA aneurysm rupture. The authors retrospectively reviewed 134 consecutive patients with PCoA aneurysms managed at their facility between July 2003 and December 2012. The authors divided patients into groups of those with aneurysmal rupture (n = 39) and without aneurysmal rupture (n = 95) and compared morphological and clinical characteristics. Morphological characteristics were mainly evaluated by 3D CT angiography and included diameter of arteries (anterior cerebral artery, middle cerebral artery, and internal carotid artery), size of the aneurysm, dome-to-neck ratio, neck direction of the aneurysmal dome around the PCoA (medial, lateral, superior, inferior, and posterior), aneurysm bleb formation, whether the PCoA was fetal type, and the existence of other intracranial unruptured aneurysm(s). Patients with ruptured PCoA aneurysms were significantly younger (a higher proportion were PCoA aneurysms showed a lateral direction of the aneurysmal dome around the PCoA, had bleb formation, and the aneurysm was > 7 mm in diameter and/or the dome-to-neck ratio was > 2.0. Multivariate logistic regression analysis showed age PCoA (OR 6.7, p = 0.0001), and bleb formation (OR 11, p PCoA aneurysm rupture. The present results demonstrated that lateral projection of a PCoA aneurysm may be related to rupture.

  10. Multidisciplinary management of the patients with cerebral aneurysm - Preliminary experience

    International Nuclear Information System (INIS)

    Gomez Hoyos, Juan Fernando; Celis Mejia, Jorge Ignacio; Yepez Sanchez, Carlos Jaime; Duque Botero, Julieta

    1998-01-01

    A Actually, complex pathologies are treated according to a decision, which is adopted, by a group of specialists from different fields concerned to the same disease. The intention is to have success that is reflected in a low morbimortality and the most complete recovery to permit patients to return their previous life activities. Depending the status of each patient, type of aneurysm and its location, different techniques are performed to exclude them from circulation. Microneurosurgery, aneurysmatic sac embolization with platinum detachable coils and vessel originating aneurysm balloon occlusion The main objective of this work is to demonstrate that both microneurosurgery, classic technique in the cerebral aneurysms management but in continuing development, and endovascular therapy are not excluded, and their effectiveness depends in a strict selection criteria of patients and a comprehensive medical management before, during and after treatment by a multidisciplinary group. Also, to evaluate both techniques based on different indexes, including the ongoing evolution. In this work the preliminary experience of the Neurovascular Group at the Clinica Cardiovascular Santa Maria in Medellin, during the period of time from December 1996 until May 1998.45 patients with 47 aneurysm were treated 55.3% aneurysmatic lesions were treated by endovascular therapy and the remaining (44.7%) by microneurosurgery. 26 patients and same number of aneurysmatic lesions composed the endovascular group, the age range was between 20 and 70 years. 80.0% were women, 20.0% men. 53.8% complained from subarachnoid hemorrhage signs and symptoms. 36.0% were in a Hunt and Hess score scale of III and 84.7% complete success was achieved. 3 patients died, 2 of them were in IV and V Hunt and Hess score scale, respectively. The surgical group composed by 19 patients with 21 lesions and an age range between 31 and 78 years. 64.8% were women and 71,5% had confirmed diagnosis of subarachnoid hemorrhage

  11. Microneurosurgical management of anterior choroid artery aneurysms.

    Science.gov (United States)

    Lehecka, Martin; Dashti, Reza; Laakso, Aki; van Popta, Jouke S; Romani, Rossana; Navratil, Ondrej; Kivipelto, Leena; Kivisaari, Riku; Foroughi, Mansoor; Kokuzawa, Jouji; Lehto, Hanna; Niemelä, Mika; Rinne, Jaakko; Ronkainen, Antti; Koivisto, Timo; Jääskelainen, Juha E; Hernesniemi, Juha

    2010-05-01

    Anterior choroid artery aneurysms (AChAAs) constitute 2%-5% of all intracranial aneurysms. They are usually small, thin walled with one or several arteries originating at their base, and often associated with multiple aneurysms. In this article, we review the practical microsurgical anatomy, the preoperative imaging, surgical planning, and the microneurosurgical steps in the dissection and the clipping of AChAAs. This review, and the whole series on intracranial aneurysms (IAs), are mainly based on the personal microneurosurgical experience of the senior author (J.H.) in two Finnish centers (Helsinki and Kuopio) that serve, without patient selection, the catchment area in Southern and Eastern Finland. These two centers have treated more than 10,000 patients with IAs since 1951. In the Kuopio Cerebral Aneurysm Database of 3005 patients with 4253 IAs, 831 patients (28%) had altogether 980 internal carotid artery (ICA) aneurysms, of whom 95 patients had 99 (2%) AChAAs. Ruptured AChAAs, found in 39 patients (41%), with median size of 6 mm (range = 2-19 mm), were associated with intracerebral hematoma (ICH) in only 1 (3%) patient. Multiple aneurysms were seen in 58 (61%) patients. The main difficulty in microneurosurgical management of AChAAs is to preserve flow in the anterior choroid artery originating at the base and often attached to the aneurysm dome. This necessitates perfect surgical strategy based on preoperative knowledge of 3 dimensional angioarchitecture and proper orientation during the microsurgical dissection. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Surgical approach to posterior inferior cerebellar artery aneurysms.

    Science.gov (United States)

    La Pira, Biagia; Sturiale, Carmelo Lucio; Della Pepa, Giuseppe Maria; Albanese, Alessio

    2018-02-01

    The far-lateral is a standardised approach to clip aneurysms of the posterior inferior cerebellar artery (PICA). Different variants can be adopted to manage aneurysms that differ in morphology, topography, ruptured status, cerebellar swelling and surgeon preference. We distinguished five paradigmatic approaches aimed to manage aneurysms that are: proximal unruptured; proximal ruptured requiring posterior fossa decompression (PFD); proximal ruptured not requiring PFD; distal unruptured; distal ruptured. Preoperative planning in the setting of PICA aneurysm surgery is of paramount importance to perform an effective and safe procedure, to ensure an adequate PFD and optimal proximal control before aneurysm manipulation.

  13. Complications of endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Orrù, Emanuele, E-mail: surgeon.ema@gmail.com [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Roccatagliata, Luca, E-mail: lroccatagliata@neurologia.unige.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy); Department of Health Sciences (DISSAL), University of Genoa (Italy); Cester, Giacomo, E-mail: giacomo.cester@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Causin, Francesco, E-mail: francesco.causin@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Castellan, Lucio, E-mail: lucio.castellan@hsanmartino.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy)

    2013-10-01

    The number of neuroendovascular treatments of both ruptured and unruptured aneurysms has increased substantially in the last two decades. Complications of endovascular treatments of cerebral aneurysms are rare but can potentially lead to acute worsening of the neurological status, to new neurological deficits or death. Some of the possible complications, such as vascular access site complications or systemic side effects associated with contrast medium (e.g. contrast medium allergy, contrast induced nephropathy) can also be encountered in diagnostic angiography. The most common complications of endovascular treatment of cerebral aneurysms are related to acute thromboembolic events and perforation of the aneurysm. Overall, the reported rate of thromboembolic complications ranges between 4.7% and 12.5% while the rate of intraprocedural rupture of cerebral aneurysms is about 0.7% in patients with unruptured aneurysms and about 4.1% in patients with previously ruptured aneurysms. Thromboembolic and hemorrhagic complications may occur during different phases of endovascular procedures and are related to different technical, clinical and anatomic reasons. A thorough knowledge of the different aspects of these complications can reduce the risk of their occurrence and minimize their clinical sequelae. A deep understanding of complications and of their management is thus part of the best standard of care.

  14. Water cooling coil

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, S; Ito, Y; Kazawa, Y

    1975-02-05

    Object: To provide a water cooling coil in a toroidal nuclear fusion device, in which coil is formed into a small-size in section so as not to increase dimensions, weight or the like of machineries including the coil. Structure: A conductor arranged as an outermost layer of a multiple-wind water cooling coil comprises a hollow conductor, which is directly cooled by fluid, and as a consequence, a solid conductor disposed interiorly thereof is cooled indirectly.

  15. Computed tomographic diagnosis of pulmonary artery aneurysm

    International Nuclear Information System (INIS)

    Maeno, Kouji; Kontani, Kazuhiro; Ito, Makoto; Sakurai, Noboru; Sawada, Taisei; Fukeda, Yasuhiko; Takata, Shigeo; Ikeda, Takayuki; Hattori, Nobu.

    1986-01-01

    Pulmonary artery aneurysms are rare lesions. Clagett et al reported that one aneurysm of the pulmonary artery may be found in approximately 14,000 necropsies. We have experienced a case of giant pulmonary artery aneurysm confirmed by computed tomography. A 38 year-old man with atrial septal defect admitted to Kanazawa City Hospital. He had been pointed out of a right hilar mass when he was 26 years old. His complaint was bloody sputum and cough. Pulmonary angiography was not useful for the definite diagnosis because of its mural thrombi. Enhanced computed tomography showed a giant pulmonary artery aneurysm with a mural thrombi in its cavity. This shows that enhanced computed tomography is very useful for the diagnosis of a pulmonary artery aneurysm with a mural thrombi in its cavity. (author)

  16. Computed tomographic diagnosis of pulmonary artery aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Maeno, Kouji; Kontani, Kazuhiro; Ito, Makoto; Sakurai, Noboru; Sawada, Taisei; Fukeda, Yasuhiko; Takata, Shigeo; Ikeda, Takayuki; Hattori, Nobu

    1986-05-01

    Pulmonary artery aneurysms are rare lesions. Clagett et al reported that one aneurysm of the pulmonary artery may be found in approximately 14,000 necropsies. We have experienced a case of giant pulmonary artery aneurysm confirmed by computed tomography. A 38 year-old man with atrial septal defect admitted to Kanazawa City Hospital. He had been pointed out of a right hilar mass when he was 26 years old. His complaint was bloody sputum and cough. Pulmonary angiography was not useful for the definite diagnosis because of its mural thrombi. Enhanced computed tomography showed a giant pulmonary artery aneurysm with a mural thrombi in its cavity. This shows that enhanced computed tomography is very useful for the diagnosis of a pulmonary artery aneurysm with a mural thrombi in its cavity.

  17. Intravenous DSA as a screening method for cerebral aneurysms

    International Nuclear Information System (INIS)

    Fukaya, Hiroyuki; Sunami, Kaneo; Hoshi, Seiichiro; Komiya, Hirokazu; Saeki, Naokatsu.

    1990-01-01

    Intravenous DSA (IVDSA) was evaluated as a screening method for cerebral aneurysms. It was performed 390 times in 372 cases. Clinically useful images were obtained in 94.1% in all examinations. Nineteen aneurysms were visualized in cerebral angiography among 21 cases with SAH or 3rd nerve palsy, whereas in IVDSA 15 aneurysms were noted. Aneurysms not visualized in IVDSA were all 4 mm or less in size. Therefore, aneurysms, more than 4 mm in size, which have higher risks for rupture, were detectable in IVDSA. Based on these findings, IVDSA is considered to be clinically useful in screening for aneurysms. In all 372 cases, 33 aneurysms were suspected in IVDSA findings, whereas in cerebral angiography 21 of them turned to be aneurysms. Such 12 false positive cases were distributed mainly at anterior communicating and middle cerebral arteries. Improvement of image resolution, avoidance of vessel overlapping and proper selection of screened cases should be investigated for further development of this screening method. (author)

  18. Aneurysm pulsatility after endovascular exclusion: an experimental study using human aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Hussein Amin Orra

    2008-01-01

    Full Text Available OBJECTIVE: To measure the pulsatility of human aneurysms before and after complete exclusion with an endograft. METHOD: Five aortic aneurysms obtained during necropsy were submitted to pulsatile perfusion before and after implantation of a bifurcated endograft. The specimens were contained in a closed chamber filled with saline solution. A vertical tube attached to the chamber was used to measure volume dislocation in each systole. Mural thrombus was kept intact, and the space around the device was filled with human blood. After each experiment, the aneurysm was opened to check for the correct positioning and attachment of the device. RESULTS: The level of the saline column oscillated during pulsation in each case, with respective amplitudes of 17, 16, 13, 7, and 25 cm before the endograft insertion. After the insertion, the amplitudes dropped to 13, 12, 9, 3.5, and 23 cm, respectively. The differences were not significant. During the post-experimental examination, all devices were found to be in position and well attached to the neck and iliacs. No endoleak was detected during perfusion or by visual inspection. CONCLUSION: Pulsation of an endograft is transmitted to the aneurysm wall even in the absence of endoleak, and should not be interpreted as procedural failure.

  19. Coiled-coil forming peptides for the induction of silver nanoparticles

    International Nuclear Information System (INIS)

    Božič Abram, Sabina; Aupič, Jana; Dražić, Goran; Gradišar, Helena; Jerala, Roman

    2016-01-01

    Biopolymers with defined sequence patterns offer an attractive alternative for the formation of silver nanoparticle (AgNP). A set of coiled-coil dimer forming peptides was tested for their AgNP formation ability. Seventeen of those peptides mediated the formation of AgNPs in aqueous solution at neutral pH, while the formation of a coiled-coil dimer inhibited the nanoparticle generation. A QSAR regression model on the relationship between sequence and function suggests that in this peptide type the patterns KXQQ and KXEE are favorable, whereas Ala residues appear to have an inhibitory effect. UV–VIS spectra of the obtained nanoparticles gave a peak at around 420 nm, typical for AgNPs in the size range around 40 nm, which was confirmed by dynamic light scattering and transmission electron microscopy. Peptide-induced AgNPs exhibited good antibacterial activity, even after a 15 min contact time, while they had low toxicity to human cells at the same concentrations. These results show that our designed peptides generate AgNPs with antibacterial activity at mild conditions and might be used for antibacterial coatings. - Highlights: • 17 of the 30 tested coiled-coil forming peptides induce AgNP formation. • Coiled-coil dimer formation suppresses AgNP generation of individual peptides. • Size of the peptide-induced silver nanoparticles is around 40 nm. • QSAR analysis points to the importance of KXQQ and KXEE motifs for AgNP generation. • Peptide-induced silver nanoparticles exhibit antibacterial activity.

  20. Coiled-coil forming peptides for the induction of silver nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Božič Abram, Sabina [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Graduate School of Biomedicine, University of Ljubljana, Ljubljana 1000 (Slovenia); Aupič, Jana [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Doctoral Programme in Chemical Sciences, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Ljubljana 1000 (Slovenia); Dražić, Goran [Laboratory for Materials Chemistry, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Gradišar, Helena [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); EN-FIST, Centre of Excellence, Trg Osvobodilne fronte 13, Ljubljana 1000 (Slovenia); Jerala, Roman, E-mail: roman.jerala@ki.si [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); EN-FIST, Centre of Excellence, Trg Osvobodilne fronte 13, Ljubljana 1000 (Slovenia)

    2016-04-08

    Biopolymers with defined sequence patterns offer an attractive alternative for the formation of silver nanoparticle (AgNP). A set of coiled-coil dimer forming peptides was tested for their AgNP formation ability. Seventeen of those peptides mediated the formation of AgNPs in aqueous solution at neutral pH, while the formation of a coiled-coil dimer inhibited the nanoparticle generation. A QSAR regression model on the relationship between sequence and function suggests that in this peptide type the patterns KXQQ and KXEE are favorable, whereas Ala residues appear to have an inhibitory effect. UV–VIS spectra of the obtained nanoparticles gave a peak at around 420 nm, typical for AgNPs in the size range around 40 nm, which was confirmed by dynamic light scattering and transmission electron microscopy. Peptide-induced AgNPs exhibited good antibacterial activity, even after a 15 min contact time, while they had low toxicity to human cells at the same concentrations. These results show that our designed peptides generate AgNPs with antibacterial activity at mild conditions and might be used for antibacterial coatings. - Highlights: • 17 of the 30 tested coiled-coil forming peptides induce AgNP formation. • Coiled-coil dimer formation suppresses AgNP generation of individual peptides. • Size of the peptide-induced silver nanoparticles is around 40 nm. • QSAR analysis points to the importance of KXQQ and KXEE motifs for AgNP generation. • Peptide-induced silver nanoparticles exhibit antibacterial activity.

  1. [Albert Einstein and his abdominal aortic aneurysm].

    Science.gov (United States)

    Cervantes Castro, Jorge

    2011-01-01

    The interesting case of Albert Einstein's abdominal aortic aneurysm is presented. He was operated on at age 69 and, finding that the large aneurysm could not be removed, the surgeon elected to wrap it with cellophane to prevent its growth. However, seven years later the aneurysm ruptured and caused the death of the famous scientist.

  2. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    International Nuclear Information System (INIS)

    Baumueller, Stephan; Nguyen, Thi Dan Linh; Goetti, Robert Paul; Lachat, Mario; Seifert, Burkhardt; Pfammatter, Thomas; Frauenfelder, Thomas

    2011-01-01

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51–88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

  3. Training model for cerebral aneurysm clipping

    Directory of Open Access Journals (Sweden)

    Hiroshi Tenjin, M.D., Ph.D.

    2017-12-01

    Full Text Available Clipping of cerebral aneurysms is still an important skill in neurosurgery. We have made a training model for the clipping of cerebral aneurysms. The concepts for the model were 1: training model for beginners, 2: three dimensional manipulation using an operating microscope, 3: the aneurysm model is to be perfused by simulated blood causing premature rupture. The correct relationship between each tissue, and softness of the brain and vessels were characteristics of the model. The skull, brain, arteries, and veins were made using a 3D printer with data from DICOM. The brain and vessels were made from polyvinyl alcohol (PVA. One training course was held and this model was useful for training of cerebral aneurysm surgery for young neurosurgeons.

  4. Models of experimental saccular aneurysms of carotid arteries in canine

    International Nuclear Information System (INIS)

    Zhang Haixia; Cheng Yingsheng; Li Minghua

    2006-01-01

    Objective: To study the availability by making experimental saccular aneurysm models of carotid arteries in canine similar to human intracranial aneurysms. Methods: Twenty healthy canines with experimental saccular side-wall aneurysms of carotid arteries were created successfully by surgery. Results: Forty experimental saccular side-wall aneurysms of carotid arteries were created successfully with 36 aneurysms and parent arteries maintaining patency with each other and four spontaneously occluded confirmed by angiography. Model successful rate reached 90%. Conclusions: Experimental saccular side-wall aneurysms of carotid arteries in canines were one of best models created for simulating human intracranial aneurysms. (authors)

  5. Impact of Right-Sided Aneurysm, Rupture Status, and Size of Aneurysm on Perforator Infarction Following Microsurgical Clipping of Posterior Communicating Artery Aneurysms with a Distal Transsylvian Approach.

    Science.gov (United States)

    Tanabe, Jun; Ishikawa, Tatsuya; Moroi, Junta; Sakata, Yoshinori; Hadeishi, Hiromu

    2018-03-01

    Posterior communicating artery (PCoA) aneurysms are among the most common aneurysms. Because blockage of the PCoA and perforators can cause adverse outcomes, occlusion of these arteries by surgical clipping should be avoided. The impact of factors on PCoA perforator infarction when using a distal transsylvian approach for PCoA aneurysms was examined. A total of 183 patients underwent PCoA aneurysm clipping, excluding application of fenestrated clips. Patients were divided into 2 groups: patients with PCoA perforator infarction (infarction group) and patients without infarction (noninfarction group). Multiple factors were analyzed in the 2 groups. Twenty-two of the 183 patients (12.0%) showed perforator infarction, mainly on magnetic resonance imaging evaluation, resulting in permanent deficits in 2 patients (1.1%). The proportion of right-sided operations (86.4% vs. 53.4%; P = 0.005) and surgery for rupture (90.9% vs. 55.9%; P = 0.002) were significantly higher in the infarction group than in the noninfarction group. Aneurysms were significantly larger in the infarction group (8.4 ± 3.8 mm) than in the noninfarction group (6.3 ± 3.0 mm; P = 0.02). Ruptured status (odds ratio [OR], 7.35; P = 0.01), right side (OR, 5.19; P = 0.01), and aneurysm size (OR, 1.18; P = 0.02) remained independent predictors of perforator infarction on multivariate logistic regression analysis. Ruptured status, right side, and large PCoA aneurysm were independent predictors of PCoA perforator infarction. Symptoms due to PCoA perforating infarction were mostly transient and rarely affected outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    Science.gov (United States)

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Automated de novo phasing and model building of coiled-coil proteins.

    Science.gov (United States)

    Rämisch, Sebastian; Lizatović, Robert; André, Ingemar

    2015-03-01

    Models generated by de novo structure prediction can be very useful starting points for molecular replacement for systems where suitable structural homologues cannot be readily identified. Protein-protein complexes and de novo-designed proteins are examples of systems that can be challenging to phase. In this study, the potential of de novo models of protein complexes for use as starting points for molecular replacement is investigated. The approach is demonstrated using homomeric coiled-coil proteins, which are excellent model systems for oligomeric systems. Despite the stereotypical fold of coiled coils, initial phase estimation can be difficult and many structures have to be solved with experimental phasing. A method was developed for automatic structure determination of homomeric coiled coils from X-ray diffraction data. In a benchmark set of 24 coiled coils, ranging from dimers to pentamers with resolutions down to 2.5 Å, 22 systems were automatically solved, 11 of which had previously been solved by experimental phasing. The generated models contained 71-103% of the residues present in the deposited structures, had the correct sequence and had free R values that deviated on average by 0.01 from those of the respective reference structures. The electron-density maps were of sufficient quality that only minor manual editing was necessary to produce final structures. The method, named CCsolve, combines methods for de novo structure prediction, initial phase estimation and automated model building into one pipeline. CCsolve is robust against errors in the initial models and can readily be modified to make use of alternative crystallographic software. The results demonstrate the feasibility of de novo phasing of protein-protein complexes, an approach that could also be employed for other small systems beyond coiled coils.

  8. Surgical management of giant posterior communicating artery aneurysms.

    Science.gov (United States)

    Velat, Gregory J; Zabramski, Joseph M; Nakaji, Peter; Spetzler, Robert F

    2012-09-01

    Giant posterior communicating artery (PCoA) aneurysms (> 25 mm) are rare lesions associated with a poor prognosis and high rates of morbidity and mortality. To review the clinical results of giant PCoA aneurysms surgically treated at our institution, focusing on operative nuances. All cases of giant PCoA aneurysms treated surgically at our institution were identified from a prospectively maintained patient database. Patient demographic factors, medical comorbidities, rupture status, neurological presentation, clinical outcomes, and surgical records were critically reviewed. From 1989 to 2010, 11 patients (10 women) underwent surgical clipping of giant PCoA aneurysms. Presenting signs and symptoms included cranial nerve palsies, diminished mental status, headache, visual changes, and seizures. Five aneurysms were ruptured on admission. All aneurysms were clipped primarily except 1, which was treated by parent artery sacrifice and extracranial-to-intracranial bypass after intraoperative aneurysm rupture. Perioperative morbidity and mortality rates were 36% (4 of 11) and 18.3% (2 of 11), respectively. Excellent or good clinical outcomes, defined as modified Rankin Scale scores ≤ 2, were achieved in 86% (5 of 6) of patients available for long-term clinical follow-up (mean, 12.5 ± 13.6 months). Giant PCoA aneurysms are rare vascular lesions that may present with a variety of neurological signs and symptoms. These lesions can be successfully managed surgically with satisfactory morbidity and mortality rates. To the best of our knowledge, this is the largest surgical series of giant PCoA aneurysms published to date.

  9. Value of three-dimensional computed tomography in screening cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Tamaki; Sugiura, Yusuke; Suzuki, Atsushi; Yamagata, Yoshitaka [Hyogo Medical Coll. (Japan)

    1997-10-01

    We performed three-dimensional computed tomography (3D-CT) in 6 patients of cerebral aneurysm. Prior cerebral angiography showed a total of 17 aneurysms. 3D-CT alone detected 10 cerebral aneurysm (59%). It was possible to identify aneurysms larger than 10 mm even when located near the circle of Willis. It was difficult to identify aneurysms when smaller than 7 mm regardless of their location. 3D-CT was of limited value in detecting cerebral aneurysms, particularly when located near the circle of Willis with complex vascular network. As cases of oculomotor palsy may be caused by lesions other than cerebral aneurysm, we advocate that 3D-CT be performed after magnetic resonance imaging (MRI) in screening cases of suspected cerebral aneurysm. (author)

  10. Shape-memory polymer foam device for treating aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Jason M.; Benett, William J.; Small, Ward; Wilson, Thomas S.; Maitland, Duncan J; Hartman, Jonathan

    2017-05-30

    A system for treating an aneurysm in a blood vessel or vein, wherein the aneurysm has a dome, an interior, and a neck. The system includes a shape memory polymer foam in the interior of the aneurysm between the dome and the neck. The shape memory polymer foam has pores that include a first multiplicity of pores having a first pore size and a second multiplicity of pores having a second pore size. The second pore size is larger than said first pore size. The first multiplicity of pores are located in the neck of the aneurysm. The second multiplicity of pores are located in the dome of the aneurysm.

  11. EARLYDRAIN- outcome after early lumbar CSF-drainage in aneurysmal subarachnoid hemorrhage: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Bardutzky, Jürgen; Witsch, Jens; Jüttler, Eric; Schwab, Stefan; Vajkoczy, Peter; Wolf, Stefan

    2011-09-14

    Aneurysmal subarachnoid hemorrhage (SAH) may be complicated by delayed cerebral ischemia, which is a major cause of unfavorable clinical outcome and death in SAH-patients. Delayed cerebral ischemia is presumably related to the development of vasospasm triggered by the presence of blood in the basal cisterns. To date, oral application of the calcium antagonist nimodipine is the only prophylactic treatment for vasospasm recognized under international guidelines.In retrospective trials lumbar drainage of cerebrospinal fluid has been shown to be a safe and feasible measure to remove the blood from the basal cisterns and decrease the incidence of delayed cerebral ischemia and vasospasm in the respective study populations. However, the efficacy of lumbar drainage has not been evaluated prospectively in a randomized controlled trial yet. This is a protocol for a 2-arm randomized controlled trial to compare an intervention group receiving early continuous lumbar CSF-drainage and standard neurointensive care to a control group receiving standard neurointensive care only. Adults suffering from a first aneurysmal subarachnoid hemorrhage whose aneurysm has been secured by means of coiling or clipping are eligible for trial participation. The effect of early CSF drainage (starting measured in the following ways: the primary endpoint will be disability after 6 months, assessed by a blinded investigator during a personal visit or standardized telephone interview using the modified Rankin Scale. Secondary endpoints include mortality after 6 months, angiographic vasospasm, transcranial Doppler sonography (TCD) mean flow velocity in both middle cerebral arteries and rate of shunt insertion at 6 months after hospital discharge. Here, we present the study design of a multicenter prospective randomized controlled trial to investigate whether early application of a lumbar drainage improves clinical outcome after aneurysmal subarachnoid hemorrhage.

  12. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  13. Aortic Disease in the Young: Genetic Aneurysm Syndromes, Connective Tissue Disorders, and Familial Aortic Aneurysms and Dissections

    Directory of Open Access Journals (Sweden)

    Marcelo Cury

    2013-01-01

    Full Text Available There are many genetic syndromes associated with the aortic aneurysmal disease which include Marfan syndrome (MFS, Ehlers-Danlos syndrome (EDS, Loeys-Dietz syndrome (LDS, familial thoracic aortic aneurysms and dissections (TAAD, bicuspid aortic valve disease (BAV, and autosomal dominant polycystic kidney disease (ADPKD. In the absence of familial history and other clinical findings, the proportion of thoracic and abdominal aortic aneurysms and dissections resulting from a genetic predisposition is still unknown. In this study, we propose the review of the current genetic knowledge in the aortic disease, observing, in the results that the causative genes and molecular pathways involved in the pathophysiology of aortic aneurysm disease remain undiscovered and continue to be an area of intensive research.

  14. Cerebral aneurysms – an audit

    African Journals Online (AJOL)

    Enrique

    Abstract. We performed an audit to determine the profile of cerebral aneurysms at the Universitas Hospital Bloem- fontein, the only government hospital with a vascular suite in the Free State and Northern Cape area. Two hun- dred and twenty-three government patients, diagnosed with cerebral aneurysms during the period.

  15. Magnetic resonance imaging of large and giant intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kenichi; Saito, Akira; Nakasu, Yoko; Matsuda, Masayuki; Handa, Jyoji [Shiga University of Medical Science, Shiga (Japan); Todo, Giro

    1990-06-01

    Twelve large or giant intracranial aneurysms were studied with magnetic resonance (MR) imaging, and the findings were compared with those from computed tomographic (CT) scanning. Characteristic MR features of such aneurysms are: round, extra-axial mass with hypointensity rim; signal void, paradoxical enhancement, or even-echo rephasing due to blood flow; and laminated, eccentric thrombus with increased signal intensity when fresh, perianeurysmal hemorrhage occurs in the acute or subacute stage after aneurysmal rupture. MR imaging, however, often fails to identify or characterize the area of calcification. For the diagnosis of large or giant intracranial aneurysms, MR imaging is apparently superior to CT scanning in differentiating aneurysms from tumors, delineating the blood flow and intraluminal thrombus, and detecting the exact size of the aneurysm. It may also provide useful information concerning the growth mechanisms of aneurysms with or without thrombus formation. (author).

  16. Conception of Brownian coil

    OpenAIRE

    Zhang, Jiayuan

    2018-01-01

    This article proposes a conception of Brownian coil. Brownian coil is a tiny coil with the same size of pollen. Once immersed into designed magnetic field and liquid, the coil will be moved and deformed macroscopically, due to the microscopic thermodynamic molecular collisions. Such deformation and movement will change the magnetic flux through the coil, by which an ElectroMotive Force (EMF) is produced. In this work, Brownian heat exchanger and Brownian generator are further designed to tran...

  17. Historical review: another 50th anniversary--new periodicities in coiled coils.

    Science.gov (United States)

    Gruber, Markus; Lupas, Andrei N

    2003-12-01

    In 1953, Francis Crick and Linus Pauling both proposed models of supercoiled alpha helices ('coiled coils') for the structure of keratin. These were the first attempts at modelling the tertiary structure of a protein. Crick emphasized the packing mode of the side-chains ('knobs-into-holes'), which required a periodicity of seven residues over two helical turns (7/2) and a supercoil in the opposite sense of the constituent helices. By contrast, Pauling envisaged a broader set of periodicities (4/1, 7/2, 18/5, 15/4, 11/3) and supercoils of both senses. Crick's model became canonical and the 'heptad repeat' essentially synonymous with coiled coils, but 50 years later new crystal structures and protein sequences show that the less common periodicities envisaged by Pauling also occur in coiled coils, adding a variant packing mode ('knobs-to-knobs') to the standard model. Pauling's laboratory notebooks suggest that he searched unsuccessfully for this packing mode in 1953.

  18. Coiled-Coil Proteins Facilitated the Functional Expansion of the Centrosome

    Science.gov (United States)

    Kuhn, Michael; Hyman, Anthony A.; Beyer, Andreas

    2014-01-01

    Repurposing existing proteins for new cellular functions is recognized as a main mechanism of evolutionary innovation, but its role in organelle evolution is unclear. Here, we explore the mechanisms that led to the evolution of the centrosome, an ancestral eukaryotic organelle that expanded its functional repertoire through the course of evolution. We developed a refined sequence alignment technique that is more sensitive to coiled coil proteins, which are abundant in the centrosome. For proteins with high coiled-coil content, our algorithm identified 17% more reciprocal best hits than BLAST. Analyzing 108 eukaryotic genomes, we traced the evolutionary history of centrosome proteins. In order to assess how these proteins formed the centrosome and adopted new functions, we computationally emulated evolution by iteratively removing the most recently evolved proteins from the centrosomal protein interaction network. Coiled-coil proteins that first appeared in the animal–fungi ancestor act as scaffolds and recruit ancestral eukaryotic proteins such as kinases and phosphatases to the centrosome. This process created a signaling hub that is crucial for multicellular development. Our results demonstrate how ancient proteins can be co-opted to different cellular localizations, thereby becoming involved in novel functions. PMID:24901223

  19. CCBuilder 2.0: Powerful and accessible coiled-coil modeling.

    Science.gov (United States)

    Wood, Christopher W; Woolfson, Derek N

    2018-01-01

    The increased availability of user-friendly and accessible computational tools for biomolecular modeling would expand the reach and application of biomolecular engineering and design. For protein modeling, one key challenge is to reduce the complexities of 3D protein folds to sets of parametric equations that nonetheless capture the salient features of these structures accurately. At present, this is possible for a subset of proteins, namely, repeat proteins. The α-helical coiled coil provides one such example, which represents ≈ 3-5% of all known protein-encoding regions of DNA. Coiled coils are bundles of α helices that can be described by a small set of structural parameters. Here we describe how this parametric description can be implemented in an easy-to-use web application, called CCBuilder 2.0, for modeling and optimizing both α-helical coiled coils and polyproline-based collagen triple helices. This has many applications from providing models to aid molecular replacement for X-ray crystallography, in silico model building and engineering of natural and designed protein assemblies, and through to the creation of completely de novo "dark matter" protein structures. CCBuilder 2.0 is available as a web-based application, the code for which is open-source and can be downloaded freely. http://coiledcoils.chm.bris.ac.uk/ccbuilder2. We have created CCBuilder 2.0, an easy to use web-based application that can model structures for a whole class of proteins, the α-helical coiled coil, which is estimated to account for 3-5% of all proteins in nature. CCBuilder 2.0 will be of use to a large number of protein scientists engaged in fundamental studies, such as protein structure determination, through to more-applied research including designing and engineering novel proteins that have potential applications in biotechnology. © 2017 The Authors Protein Science published by Wiley Periodicals, Inc. on behalf of The Protein Society.

  20. NET model coil test possibilities

    International Nuclear Information System (INIS)

    Erb, J.; Gruenhagen, A.; Herz, W.; Jentzsch, K.; Komarek, P.; Lotz, E.; Malang, S.; Maurer, W.; Noether, G.; Ulbricht, A.; Vogt, A.; Zahn, G.; Horvath, I.; Kwasnitza, K.; Marinucci, C.; Pasztor, G.; Sborchia, C.; Weymuth, P.; Peters, A.; Roeterdink, A.

    1987-11-01

    A single full size coil for NET/INTOR represents an investment of the order of 40 MUC (Million Unit Costs). Before such an amount of money or even more for the 16 TF coils is invested as much risks as possible must be eliminated by a comprehensive development programme. In the course of such a programme a coil technology verification test should finally prove the feasibility of NET/INTOR TF coils. This study report is almost exclusively dealing with such a verification test by model coil testing. These coils will be built out of two Nb 3 Sn-conductors based on two concepts already under development and investigation. Two possible coil arrangements are discussed: A cluster facility, where two model coils out of the two Nb 3 TF-conductors are used, and the already tested LCT-coils producing a background field. A solenoid arrangement, where in addition to the two TF model coils another model coil out of a PF-conductor for the central PF-coils of NET/INTOR is used instead of LCT background coils. Technical advantages and disadvantages are worked out in order to compare and judge both facilities. Costs estimates and the time schedules broaden the base for a decision about the realisation of such a facility. (orig.) [de

  1. Predictors of Shunt-dependent Hydrocephalus After Aneurysmal Subarachnoid Hemorrhage? A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Xie, Zhiyi; Hu, Xin; Zan, Xin; Lin, Sen; Li, Hao; You, Chao

    2017-10-01

    Hydrocephalus is a well-recognized complication after aneurysmal subarachnoid hemorrhage (aSAH). This study aimed to identify predictors for shunt-dependent hydrocephalus (SDHC) after aSAH via a systematic review and meta-analysis. A systematic search was conducted using the Embase, MEDLINE, and Web of Science databases for studies pertaining to aSAH and SDHC. Risk factors were assessed by meta-analysis when they were reported by at least 2 studies. The results were presented as odd ratios or risk ratios according to the study design with the corresponding 95% confidence intervals (CI). Twenty-five studies were included. In primary analysis of 14 potential risk factors, 12 were identified as predictors of SDHC after aSAH including age ≥50 years, female gender, high Hunt-Hess grade, Glasgow Coma Scale ≤8, Fisher grade ≥3, acute hydrocephalus, external ventricular drainage insertion, intraventricular hemorrhage, postcirculation aneurysm, anterior communicating artery aneurysm, meningitis, and rebleeding. The meta-analysis based on cohort studies found a significantly increased risk for SDHC in patients with aSAH treated by coiling (risk ratio, 1.16; 95% CI, 1.05-1.29), while the meta-analysis based on case-controlled studies failed to replicate this finding (odds ratio, 1.27; 95% CI, 0.95-1.71). Several new predictors of SDHC after aSAH were identified that may assist with the early recognition and prevention of SDHC. The controversial evidence found in this study was insufficient to support the potential of neurosurgical clipping for reducing the risk of shunt dependency. Further well-designed studies are warranted to explore the effect of treatment modality on SDHC risk. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    Science.gov (United States)

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  3. Is tube repair of aortic aneurysm followed by aneurysmal change in the common iliac arteries?

    Science.gov (United States)

    Provan, J L; Fialkov, J; Ameli, F M; St Louis, E L

    1990-10-01

    To address the concern that tube repair of an abdominal aortic aneurysm might be followed by aneurysmal change in the common iliac arteries, 23 patients who had undergone the operation were re-examined 3 to 5 years later. Although 9 had had minimal ectasia of these arteries preoperatively, in none of the 23 was there symptomatic or radiologic evidence of aneurysmal change on follow-up. Measurements of the maximum intraluminal diameters were made by computed tomography; they indicated no significant differences between the preoperative and follow-up sizes of the common iliac arteries. The variation in time to follow-up also showed no significant correlation with change in artery diameter.

  4. Dual coil ignition system

    Energy Technology Data Exchange (ETDEWEB)

    Huberts, Garlan J.; Qu, Qiuping; Czekala, Michael Damian

    2017-03-28

    A dual coil ignition system is provided. The dual coil ignition system includes a first inductive ignition coil including a first primary winding and a first secondary winding, and a second inductive ignition coil including a second primary winding and a second secondary winding, the second secondary winding connected in series to the first secondary winding. The dual coil ignition system further includes a diode network including a first diode and a second diode connected between the first secondary winding and the second secondary winding.

  5. Morphology parameters for intracranial aneurysm rupture risk assessment.

    Science.gov (United States)

    Dhar, Sujan; Tremmel, Markus; Mocco, J; Kim, Minsuok; Yamamoto, Junichi; Siddiqui, Adnan H; Hopkins, L Nelson; Meng, Hui

    2008-08-01

    The aim of this study is to identify image-based morphological parameters that correlate with human intracranial aneurysm (IA) rupture. For 45 patients with terminal or sidewall saccular IAs (25 unruptured, 20 ruptured), three-dimensional geometries were evaluated for a range of morphological parameters. In addition to five previously studied parameters (aspect ratio, aneurysm size, ellipticity index, nonsphericity index, and undulation index), we defined three novel parameters incorporating the parent vessel geometry (vessel angle, aneurysm [inclination] angle, and [aneurysm-to-vessel] size ratio) and explored their correlation with aneurysm rupture. Parameters were analyzed with a two-tailed independent Student's t test for significance; significant parameters (P 41; 95% confidence interval, 1.03-1.92) and undulation index (odds ratio, 1.51; 95% confidence interval, 1.08-2.11) had the strongest independent correlation with ruptured IA. From the receiver operating characteristic analysis, size ratio and aneurysm angle had the highest area under the curve values of 0.83 and 0.85, respectively. Size ratio and aneurysm angle are promising new morphological metrics for IA rupture risk assessment. Because these parameters account for vessel geometry, they may bridge the gap between morphological studies and more qualitative location-based studies.

  6. Infectious or Noninfectious? Ruptured, Thrombosed Inflammatory Aortic Aneurysm with Spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Stefanczyk, Ludomir; Elgalal, Marcin, E-mail: telgalal@yahoo.co.uk [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Papiewski, Andrzej [Medical University of Lodz, Department of Gastroenterological Surgery (Poland); Szubert, Wojciech [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Szopinski, Piotr [Institute of Hematology and Transfusion Medicine, Clinic of Vascular Surgery (Poland)

    2013-06-15

    Osteolysis of vertebrae due to inflammatory aortic aneurysm is rarely observed. However, it is estimated that up to 10 % of infectious aneurysms coexist with bone tissue destruction, most commonly the vertebrae. Inflammatory aneurysms with no identified infection factor, along with infiltration of adjacent muscle and in particular extensive destruction of bone tissue have rarely been described in the literature. A case of inflammatory aneurysm with posterior wall rupture and inflammatory infiltration of the iliopsoas muscle and spine, together with extensive vertebral body destruction, is presented. The aneurysm was successfully treated with endovascular aneurysm repair EVAR.

  7. Infectious or Noninfectious? Ruptured, Thrombosed Inflammatory Aortic Aneurysm with Spondylolysis

    International Nuclear Information System (INIS)

    Stefańczyk, Ludomir; Elgalal, Marcin; Papiewski, Andrzej; Szubert, Wojciech; Szopiński, Piotr

    2013-01-01

    Osteolysis of vertebrae due to inflammatory aortic aneurysm is rarely observed. However, it is estimated that up to 10 % of infectious aneurysms coexist with bone tissue destruction, most commonly the vertebrae. Inflammatory aneurysms with no identified infection factor, along with infiltration of adjacent muscle and in particular extensive destruction of bone tissue have rarely been described in the literature. A case of inflammatory aneurysm with posterior wall rupture and inflammatory infiltration of the iliopsoas muscle and spine, together with extensive vertebral body destruction, is presented. The aneurysm was successfully treated with endovascular aneurysm repair EVAR.

  8. Comprehensive Overview of Contemporary Management Strategies for Cerebral Aneurysms.

    Science.gov (United States)

    Manhas, Amitoz; Nimjee, Shahid M; Agrawal, Abhishek; Zhang, Jonathan; Diaz, Orlando; Zomorodi, Ali R; Smith, Tony; Powers, Ciarán J; Sauvageau, Eric; Klucznik, Richard P; Ferrell, Andrew; Golshani, Kiarash; Stieg, Philip E; Britz, Gavin W

    2015-10-01

    Aneurysmal subarachnoid hemorrhage (SAH) remains an important health issue in the United States. Despite recent improvements in the diagnosis and treatment of cerebral aneurysms, the mortality rate following aneurysm rupture. In those patients who survive, up to 50% are left severely disabled. The goal of preventing the hemorrhage or re-hemorrhage can only be achieved by successfully excluding the aneurysm from the circulation. This article is a comprehensive review by contemporary vascular neurosurgeons and interventional neuroradiolgists on the modern management of cerebral aneurysms. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  10. Treatment strategy for ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Davidovic, L

    2014-07-01

    Rupture is the most serious and lethal complication of the abdominal aortic aneurysm. Despite all improvements during the past 50 years, ruptured abdominal aortic aneurysms are still associated with very high mortality. Namely, including patients who die before reaching the hospital, the mortality rate due to abdominal aortic aneurysm rupture is 90%. On the other hand, during the last twenty years, the number of abdominal aortic aneurysms significantly increased. One of the reasons is the fact that in majority of countries the general population is older nowadays. Due to this, the number of degenerative AAA is increasing. This is also the case for patients with abdominal aortic aneurysm rupture. Age must not be the reason of a treatment refusal. Optimal therapeutic option ought to be found. The following article is based on literature analysis including current guidelines but also on my Clinics significant experience. Furthermore, this article show cases options for vascular medicine in undeveloped countries that can not apply endovascular procedures at a sufficient level and to a sufficient extent. At this moment the following is evident. Thirty-day-mortality after repair of ruptured abdominal aortic aneurysms is significantly lower in high-volume hospitals. Due to different reasons all ruptured abdominal aortic aneurysms are not suitable for EVAR. Open repair of ruptured abdominal aortic aneurysm should be performed by experienced open vascular surgeons. This could also be said for the treatment of endovascular complications that require open surgical conversion. There is no ideal procedure for the treatment of AAA. Each has its own advantages and disadvantages, its own limits and complications, as well as indications and contraindications. Future reductions in mortality of ruptured abdominal aortic aneurysms will depend on implementation of population-based screening; on strategies to prevent postoperative organ injury and also on new medical technology

  11. TFTR toroidal field coil design

    International Nuclear Information System (INIS)

    Smith, G.E.; Punchard, W.F.B.

    1977-01-01

    The design of the Tokamak Fusion Test Reactor (TFTR) Toroidal Field (TF) magnetic coils is described. The TF coil is a 44-turn, spiral-wound, two-pancake, water-cooled configuration which, at a coil current of 73.3 kiloamperes, produces a 5.2-Tesla field at a major radius of 2.48 meters. The magnetic coils are installed in titanium cases, which transmit the loads generated in the coils to the adjacent supporting structure. The TFTR utilizes 20 of these coils, positioned radially at 18 0 intervals, to provide the required toroidal field. Because it is very highly loaded and subject to tight volume constraints within the machine, the coil presents unique design problems. The TF coil requirements are summarized, the coil configuration is described, and the problems highlighted which have been encountered thus far in the coil design effort, together with the development tests which have been undertaken to verify the design

  12. NCSX Toroidal Field Coil Design

    International Nuclear Information System (INIS)

    Kalish M; Rushinski J; Myatt L; Brooks A; Dahlgren F; Chrzanowski J; Reiersen W; Freudenberg K.

    2005-01-01

    The National Compact Stellarator Experiment (NCSX) is an experimental device whose design and construction is underway at the Department of Energy's Princeton Plasma Physics Laboratory (PPPL). The primary coil systems for the NCSX device consist of the twisted plasma-shaping Modular Coils, the Poloidal Field Coils, and the Toroidal Field (TF) Coils. The TF Coils are D-shaped coils wound from hollow copper conductor, and vacuum impregnated with a glass-epoxy resin system. There are 18 identical, equally spaced TF coils providing 1/R field at the plasma. They operate within a cryostat, and are cooled by LN2, nominally, to 80K. Wedge shaped castings are assembled to the inboard face of these coils, so that inward radial loads are reacted via the nesting of each of the coils against their adjacent partners. This paper outlines the TF Coil design methodology, reviews the analysis results, and summarizes how the design and analysis support the design requirements

  13. A fluid-structure interaction study using patient-specific ruptured and unruptured aneurysm: the effect of aneurysm morphology, hypertension and elasticity.

    Science.gov (United States)

    Lee, C J; Zhang, Y; Takao, H; Murayama, Y; Qian, Y

    2013-09-27

    Fluid-structure interaction (FSI) simulations using five patient-specific aneurysm geometries are carried out to investigate the difference between ruptured and unruptured aneurysms. Two different blood pressure conditions (normal and hypertension, for all cases), and two different values of elastic modulus (1 and 2MPa, for two cases) are tested. Ruptured aneurysms (RA) generally displayed larger displacement at the dome, lower area-average WSS and higher von Mises stress than unruptured aneurysms (URA) regardless of elasticity or blood pressure condition. RAs had a longitudinal expansion whereas URAs had a radial expansion, which was the key difference between the two types. The difference in expansion pattern may be one of the keys to explaining aneurysm rupture, and further analysis is required in the future to confirm this theory. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Biochemical changes related to hypoxia during cerebral aneurysm surgery: combined microdialysis and tissue oxygen monitoring: case report.

    Science.gov (United States)

    Hutchinson, P J; Al-Rawi, P G; O'Connell, M T; Gupta, A K; Pickard, J D; Kirkpatrick, P J

    2000-01-01

    The objective of this study was to monitor brain metabolism on-line during aneurysm surgery, by combining the use of a multiparameter (brain tissue oxygen, brain carbon dioxide, pH, and temperature) sensor with microdialysis (extracellular glucose, lactate, pyruvate, and glutamate). The case illustrates the potential value of these techniques by demonstrating the effects of adverse physiological events on brain metabolism and the ability to assist in both intraoperative and postoperative decision-making. A 41-year-old woman presented with a World Federation of Neurological Surgeons Grade I subarachnoid hemorrhage. Angiography revealed a basilar artery aneurysm that was not amenable to coiling, so the aneurysm was clipped. Before the craniotomy was performed, a multiparameter sensor and a microdialysis catheter were inserted to monitor brain metabolism. During the operation, the brain oxygen level decreased, in relation to biochemical changes, including the reduction of extracellular glucose and pyruvate and the elevation of lactate and glutamate. These changes were reversible. However, when the craniotomy was closed, a second decrease in brain oxygen occurred in association with brain swelling, which immediately prompted a postoperative computed tomographic scan. The scan demonstrated acute hydrocephalus, requiring external ventricular drainage. The patient made a full recovery. The monitoring techniques influenced clinical decision-making in the treatment of this patient. On-line measurement of brain tissue gases and extracellular chemistry has the potential to assist in the perioperative and postoperative management of patients undergoing complex cerebrovascular surgery and to establish the effects of intervention on brain homeostasis.

  15. [Transesophageal echocardiography diagnosis of ruptured aneurysm of the Valsalva sinus associated with aneurysm of the interatrial septum].

    Science.gov (United States)

    Imperadore, Ferdinando; Ferro, Aldo; Graffigna, Angelo; Vergara, Giuseppe

    2002-01-01

    Aneurysms of the sinus of Valsalva are uncommon heart defects that often remain undetected unless rupture occurs. They have been reported in association with other cardiac anomalies. The present case report deals with a 51-year-old man who was referred to our division with a diagnosis of recent-onset progressive heart failure. Echocardiographic evaluation, both transthoracic and transesophageal, disclosed rupture of an aneurysm of the non-coronary sinus of Valsalva into the right atrium. This anomaly was associated with an aneurysm of the atrial septum.

  16. CT findings of subarachnoid hemorrhage due to ruptured cerebral aneurysm

    International Nuclear Information System (INIS)

    Kim, Pyo Nyun; Bae, Won Kyung; Kim, Il Young; Lee, Kyung Soo; Lee, Byoung Ho; Kim, Ki Jung

    1990-01-01

    CT scans were analysed retrospectively in 130 patients with subarachnoid hemorrhage (SAH) due to ruptured cerebral aneurysm to evaluate the relationship of the locations of aneurysms and the patterns of hemorrhage. Hemorrhage corresponded to the site of aneurysmal origin in a general way and in more specific ways to anterior communicating and middle cerebral artery aneurysms when there was parenchymal or cisternal hemorrhage. In anterior communicating artery aneurysm, SAH in the interhemispheric fissure, both sylvian fissures, and basal cistern was usually noted and intracerebral hemorrhage in anteroinferior frontal lobe was sometimes associated. In cases of middle cerebral artery aneurysm, hemorrhage in the ipsilateral sylvian fissure, interhemispheric fissure, and ipsilateral basal cistern was usual. Intracerebral hemorrhage in lateral temporal lobe was sometimes associated. Posterior communicating artery aneurysm demonstrated SAH in the ipsilateral basal cistern or in entire cisternal spaces specifically, so with higher incidence of involvement of the quadrigeminal and superior cerebellar cistern than anterior cerebral or middle cerebral artery aneurysm. We suggest the locations of aneurysm might be predicted with patterns of SAH and / or associated intracerebral hemorrhage with CT

  17. Endoport-Assisted Microsurgical Treatment of a Ruptured Periventricular Aneurysm

    Directory of Open Access Journals (Sweden)

    Ching-Jen Chen

    2016-01-01

    Full Text Available Background and Importance. Ruptured periventricular aneurysms in patients with moyamoya disease represent challenging pathologies. The most common methods of treatment include endovascular embolization and microsurgical clipping. However, rare cases arise in which the location and anatomy of the aneurysm make these treatment modalities particularly challenging. Clinical Presentation. We report a case of a 34-year-old female with moyamoya disease who presented with intraventricular hemorrhage. CT angiography and digital subtraction angiography revealed an aneurysm located in the wall of the atrium of the right lateral ventricle. Distal endovascular access was not possible, and embolization risked the sacrifice of arteries supplying critical brain parenchyma. Using the BrainPath endoport system, the aneurysm was able to be accessed. Since the fusiform architecture of the aneurysm prevented clip placement, the aneurysm was ligated with electrocautery. Conclusion. We demonstrate the feasibility of endoport-assisted approach for minimally invasive access and treatment of uncommon, distally located aneurysms.

  18. Traumatic intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Kang, Si Won; Chun, Kyung Ah; Baik, Joon Hyun; Shin, Kyung Sub

    1994-01-01

    The occurrence of traumatic aneurysm is rare in head injury, but this complication is important as it is a potentially treatable cause delayed onset of intracranial hemorrhage. Authors report one case of traumatic aneurysm involving A1 and A2 junction of anterior cerebral artery. A-28-year-old man with traffic accident was examined with brain CT and cerebral angiography. 1) Brain CT: Initial scan shows multiple skull fractures involving right frontal bones with subarachnoid hemorrhage and pneumocephalus. Follow-up scan shows intracerebral hemorrhage at bilateral frontal lobes. 2) Cerebral angiography: A traumatic aneurysm which is slowly filling and delayed emptying is noted at the junctional portion of A1 and A2 segment of the anterior cerebral artery. This report demonstrates radiologic findings of traumatic aneurysm at anterior cerebral artery with the brief review of the literatures

  19. Four signature motifs define the first class of structurally related large coiled-coil proteins in plants.

    Directory of Open Access Journals (Sweden)

    Meier Iris

    2002-04-01

    Full Text Available Abstract Background Animal and yeast proteins containing long coiled-coil domains are involved in attaching other proteins to the large, solid-state components of the cell. One subgroup of long coiled-coil proteins are the nuclear lamins, which are involved in attaching chromatin to the nuclear envelope and have recently been implicated in inherited human diseases. In contrast to other eukaryotes, long coiled-coil proteins have been barely investigated in plants. Results We have searched the completed Arabidopsis genome and have identified a family of structurally related long coiled-coil proteins. Filament-like plant proteins (FPP were identified by sequence similarity to a tomato cDNA that encodes a coiled-coil protein which interacts with the nuclear envelope-associated protein, MAF1. The FPP family is defined by four novel unique sequence motifs and by two clusters of long coiled-coil domains separated by a non-coiled-coil linker. All family members are expressed in a variety of Arabidopsis tissues. A homolog sharing the structural features was identified in the monocot rice, indicating conservation among angiosperms. Conclusion Except for myosins, this is the first characterization of a family of long coiled-coil proteins in plants. The tomato homolog of the FPP family binds in a yeast two-hybrid assay to a nuclear envelope-associated protein. This might suggest that FPP family members function in nuclear envelope biology. Because the full Arabidopsis genome does not appear to contain genes for lamins, it is of interest to investigate other long coiled-coil proteins, which might functionally replace lamins in the plant kingdom.

  20. Construct canine intracranial aneurysm model by endovascular technique

    International Nuclear Information System (INIS)

    Liang Xiaodong; Liu Yizhi; Ni Caifang; Ding Yi

    2004-01-01

    Objective: To construct canine bifurcation aneurysms suitable for evaluating the exploration of endovascular devices for interventional therapy by endovascular technique. Methods: The right common carotid artery of six dogs was expanded with a pliable balloon by means of endovascular technique, then embolization with detached balloon was taken at their originations DAS examination were performed on 1, 2, 3 d after the procedurse. Results: 6 aneurysm models were created in six dogs successfully with the mean width and height of the aneurysms decreasing in 3 days. Conclusions: This canine aneurysm model presents the virtue in the size and shape of human cerebral bifurcation saccular aneurysms on DSA image, suitable for developing the exploration of endovascular devices for aneurismal therapy. The procedure is quick, reliable and reproducible. (authors)